Professional Documents
Culture Documents
Dywidag High Strength Bars
Dywidag High Strength Bars
DYWIDAG
Steel
Grade
Ultimate
Strength
fpu
mm
16
20
25
28
32
40
50
63.5
N/mm2
500/600
500/600
500/600
500/600
500/600
500/600
500/600
555/700
kN
121
188
295
370
482
756
1176
2217
Yield
Strength
kN
100
157
245
308
402
630
980
1758
70% (b)
Ultimate
Strength
50%
Ultimate
Strength
Cross
Sectional
Area
Diameter
Over
Threads
Thread
Pitch
Bar
Weight
kN
85
132
206
259
337
529
823
1552
kN
61
94
147
185
241
378
588
1108
mm2
201
314
491
616
804
1260
1960
3167
mm
19
23
28
32
36
45
56
69
mm
8
10
12.5
14
16
20
26
21
kg/m
1.58
2.47
3.85
4.83
6.31
9.87
15.40
24.80
standard coupling
Lock nuts should be used at each end of the coupler when the threadbar is used in reinforced concrete applications designed in
accordance with BS 8110. These lock nuts should be torqued to a predetermined value to prevent cracking of the structural concrete
at the coupler when the joint comes under load. See table on Page 3 for torque values.
Flat Plate
Stock Size *
mm
16
20
25
28
32
40
50
63.5
mm
150 x 150 x 10
150 x 150 x 10
150 x 150 x 10
150 x 150 x 10
200 x 200 x 30
200 x 200 x 40
300 x 300 x 50
300 x 300 x 50
(a)
Hexagonal Nut
AF
Length
mm
mm
32
40
36
45
41
50
46
55
55
60
65
70
80
85
100
115
Domed Nut
AF
Length
mm
mm
Recessed Plate
Stock Size *
mm
150 x 150 x 20
150 x 150 x 20
150 x 150 x 20
150 x 150 x 20
200 x 200 x 30
200 x 200 x 40
300 x 300 x 50
(b)
35
38
43
46
(a)
41
45
54
57
Lock Nut
AF
Length
mm
mm
32
30
32
40
41
40
41
45
50
50
65
70
80
85
100
115
Formed Plate
Stock Size *
mm
150 x 150 x 10
150 x 150 x 10
150 x 150 x 10
150 x 150 x 10
Torque
Value
Nm
300
400
700
950
1500**
2900**
8000**
8000**
AF
mm
30
36
41
46
50
60
80
100
Hemisphere
Dia.
Length
mm
mm
46
18
46
18
57
23
57
23
80
33
120
55
120
60
Flanged Nut
Length
mm
35
40
45
50
60
70
85
115
Dia.
mm
50
60
70
85
100
120
150
250
Nuts
Plates
Hexagonal Nut
Flat Plate
Domed Nut
Lock Nut
Formed Plate
Articulating Plate
up to 20
up to 30
Flanged Nut
Gusseted Plate
up to 45
Couplers
Static Coupler
Dynamic Coupler
Contact Coupler
Transition Coupler
Accessories
Mechanical Shell
Tapered Washer
Hemisphere
Lifting Shackle
up to 15
up to 30
Corrosion Protection
Galvanizing to BS EN ISO 1461 : 1999
Rock Bolts
Soil Nails
Temporary Ground Anchors
Applications
Soil Nails
Mini Piles
Reinforcement
Rock Bolts
Lifting Bolts
Ground Anchors
Stressing Equipment
Jack Selection Chart
Capacity
Stroke
Weight
100kN
150mm
15kg
140kN
150mm
15kg
300kN
50mm
21kg
300kN
150mm
36kg
600kN
50mm
37kg
1100kN
50mm
46kg
1500kN
180mm
50kg
250mm
180kg
2000kN
16
20
25
Bar Diameter mm
28
32
40
50
63.5
Stressing Dimensions
Steel
Grade
Dim.
A
Dim.
B
mm
N/mm2
mm
mm
16
500/600
40
45
20
500/600
45
55
25
500/600
50
60
28
500/600
55
65
32
500/600
60
70
40
500/600
70
80
50
500/600
85
100
63.5
555/700
115
130
Dimension B is the minimum threadbar projection required for stressing.
01926 813980
01926 813817
sales@dywidag.co.uk
www.dywidag-systems.com/uk
Quality Assurance
DYWIDAG-Systems International
Certificate Number
FM 25723
Nominal
Diameter