Typical Interior Column: B-2, B-3, B-4

Roof:
At (15

Dead Load:

WD 25.3

Live Load:

WL 20

Reduced Live Load:

R1 0.6

For Tributary Area Greater


than 600 ft^2

R2 1

For Pitch less than 4in/ft

+ 15

) (19

3
) = 1.14 10

Tributary Area:

+ 19

L WL R1 R2 = 12

Factored Load:

Wu max 1.2 WD + 1.6 L , 1.2 WD + 0.5 L


Wu = 49.56
Pu Wu At = 56.498

Chosen Section: W12x40

Pn 340
@KL=14 ft
340 kip > 56.5 kip design OK

Typical Interior Column: B-2, B-3, B-4

Created with PTC Mathcad Express. See www.mathcad.com for more information.

Typical Interior Column: B-2, B-3, B-4


Floor 6:
Tributary Area:

At (15

Dead Load:

WD 58.8

Live Load:

WL 50

Reduced Live Load:

KLL 4

+ 15

) (19

+ 19

3
) = 1.14 10

15
L max WL 0.25 +
, 0.5 WL = 25

KLL At

Lr 12

Factored Load:

Wu max 1.2 WD + 1.6 L + 0.5 Lr , 1.2 WD + 0.5 L


Wu = 116.56
Pu Wu At = 132.878
Pcumulative Pu + 56.50

Chosen Section: W12x50

= 189.378

Pn 270
@KL=18 ft
270 kip > 189.378 kip design OK

Typical Interior Column: B-2, B-3, B-4

Created with PTC Mathcad Express. See www.mathcad.com for more information.

Typical Interior Column: B-2, B-3, B-4


Floor 5:
Tributary Area:

At (15

+ 15

) (19

Acumulative At + 1140
Dead Load:

WD 58.8

Live Load:

WL 50

Reduced Live Load:

KLL 4

+ 19
2

3
) = 1.14 10

3
= 2.28 10

15
L max WL 0.25 +
, 0.4 WL = 20.354

KLL Acumulative

Lr 12

Factored Load:

Wu max 1.2 WD + 1.6 L + 0.5 Lr , 1.2 WD + 0.5 L


Wu = 109.126
Pu Wu At = 124.403
Pcumulative Pu + 189.378

Chosen Section: W12x50

= 313.781

Pn 326
@KL=16 ft
326 kip > 313.781 kip design OK

Typical Interior Column: B-2, B-3, B-4

Created with PTC Mathcad Express. See www.mathcad.com for more information.

Typical Interior Column: B-2, B-3, B-4


Floor 4:
Tributary Area:

At (15

+ 15

) (19

Acumulative At + 2280
Dead Load:

WD 58.8

Live Load:

WL 50

Reduced Live Load:

KLL 4

+ 19
2

3
) = 1.14 10

3
= 3.42 10

15
L max WL 0.25 +
, 0.4 WL = 20

KLL Acumulative

Lr 12

Factored Load:

Wu max 1.2 WD + 1.6 L + 0.5 Lr , 1.2 WD + 0.5 L


Wu = 108.56
Pu Wu At = 123.758
Pcumulative Pu + 313.781

Chosen Section: W12x65

= 437.539

Pn 640
@KL=16 ft
640 kip > 437.539 kip design OK

Typical Interior Column: B-2, B-3, B-4

Created with PTC Mathcad Express. See www.mathcad.com for more information.

Typical Interior Column: B-2, B-3, B-4


Floor 3:
Tributary Area:

At (15

+ 15

) (19

Acumulative At + 3 1140
Dead Load:

WD 58.8

Live Load:

WL 50

Reduced Live Load:

KLL 4

+ 19
2

3
) = 1.14 10

3
= 4.56 10

15
L max WL 0.25 +
, 0.4 WL = 20

KLL Acumulative

Lr 12

Factored Load:

Wu max 1.2 WD + 1.6 L + 0.5 Lr , 1.2 WD + 0.5 L


Wu = 108.56
Pu Wu At = 123.758
Pcumulative Pu + 437.539

Chosen Section: W12x65

= 561.297

Pn 640
@KL=16 ft
640 kip > 561.297 kip design OK

Typical Interior Column: B-2, B-3, B-4

Created with PTC Mathcad Express. See www.mathcad.com for more information.

Typical Interior Column: B-2, B-3, B-4


Floor 2:
Tributary Area:

At (15

+ 15

) (19

Acumulative At + 4 1140
Dead Load:

WD 58.8

Live Load:

WL 50

Reduced Live Load:

KLL 4

+ 19
2

3
) = 1.14 10

3
= 5.7 10

15
L max WL 0.25 +
, 0.4 WL = 20

KLL Acumulative

Lr 12

Factored Load:

Wu max 1.2 WD + 1.6 L + 0.5 Lr , 1.2 WD + 0.5 L


Wu = 108.56
Pu Wu At = 123.758
Pcumulative Pu + 561.297

Chosen Section: W12x79

= 685.055

Pn 694
@KL=19 ft
694 kip > 685.055 kip design OK

Created with PTC Mathcad Express. See www.mathcad.com for more information.