You are on page 1of 17

BTS3900 Configuration

Level: internal

BTS3900 Configuration Guideline

Drafted by

Quan Kuifa

Date

Reviewed by

Date

Approved by

Date

JUN.10.2009

Huawei Technologies Co., Ltd.


All rights reserved.

2009-7-2

Page1, Total17

BTS3900 Configuration

Level: internal

This guide instructs that how to configur BTS3900 in the BSC6000.also that
how to implement BTS swap.All the operations is based on the LMT and MML.
The content of this guide is as below:
1, Main process of BTS configuration
2, Alarm configuration for BTS
3, Data configuration for BTS swap

2009-7-2

Page2, Total17

BTS3900 Configuration

Level: internal

1. Main process of BTS configuration


Keep the same configuartion with site Batna CCLT 05503 in the Batna.
Step1: add site

Step2: add cell

2009-7-2

Page3, Total17

BTS3900 Configuration

Level: internal

Step3: set attributes

2009-7-2

Page4, Total17

BTS3900 Configuration

Level: internal

Step4: add FMU and GATM board


(Each BTS3900 is configured with 6 DRFU.1 FMU.1 GATM.1 BBU.)
Add FMU in slot 8 and GATM in slot 17, because the monitor signal cable of
FMU and GATM are connected to MON0 and MON1 of UPEU
separately.which keeps the confiuration same with the practical installation.

2009-7-2

Page5, Total17

BTS3900 Configuration

Level: internal

Step5: add RXU Chain

2009-7-2

Page6, Total17

BTS3900 Configuration

Level: internal

Use the RF cable connection tool to generate the connection. For the site
05503(S4/4/4) is as below:

2009-7-2

Page7, Total17

BTS3900 Configuration

Level: internal

Step6: add RXU (RFU)


Principia for RXUs name: PortX_SlotX_PosX.
PortX: Port No. X of GTMU
SlotX: Slot No. X of DRFU
PosX: Position No.X of the DRFU in the chain.

Keep confiuration same with the practical connection.Finally the RXU chain
topo is as below.

2009-7-2

Page8, Total17

BTS3900 Configuration

Level: internal

Step7: bind logical TRX


From Trx No.0 to Trx No.11

Step8: Set TRX attributes (Send Receive Mode)

2009-7-2

Page9, Total17

BTS3900 Configuration

Level: internal

Set the Send Receive Mode due to pratical situation. Because just one ANT
port of DRFU is used, the Single Antenna Double Receiver is chosen.

Step9: Set cell attributes


Almost the configuration process is same with BSC32.
One parameter should be cared, which isPower Type. 20W is chosen due
to the Send Receive Mode.

2009-7-2

Page10, Total17

BTS3900 Configuration

Level: internal

2. Alarm configuration for BTS3900


The BBU can support 2 RS485 bus and 16 line of on-off alarm maximally.
There are just 1 UPEU configured in BTS3900 in the packeting list.
The No. of on-off alarm for UPEU is as below.

The monitor signal of DCDU-01 is connected to No.8 alarm of EXT-ALM0 of


UPEU.
Step1: set site attributes

Step2: set Alarm Shield Flag 2 (Hex)


The 8 bits (from low to high) of alarm sheild flag 2 determines the No.8-15
on-off alarm. 0 means shield, 1 means non-shield.
The alarm sheild flag 2 is set as 01 to enable the DCDU-01 arlarm.

2009-7-2

Page11, Total17

BTS3900 Configuration

Level: internal

Step3: set Alarm Voltage Definition

2009-7-2

Page12, Total17

BTS3900 Configuration

Level: internal

Step4: set external alarm port


Set the external alarm port for the on-off alarm of the UPEU as below.

Step5: name the external alarm


Click the Alarm Matintenance in the LMT mean

Find the No.5048 alarm.then right-click it.choose as below.

2009-7-2

Page13, Total17

BTS3900 Configuration

Level: internal

Set the Alarm name.

2009-7-2

Page14, Total17

BTS3900 Configuration

Level: internal

3. Data configuration for BTS swap


Step1: configure the site with LMT in offline mode
Note: Configure the site on the same slot and port as the site to be swapped.

Step2: export the site data in offline mode

It will take about 5 minutes to export one site data.


Step3: backup the data of the swapped site in online mode
Note: do this after blocking the site.

2009-7-2

Page15, Total17

BTS3900 Configuration

Level: internal

The exported result is the format of text as above, which will be used to edit the
adjacent cell for BTS3900 later.
Step4: delete the swapped site in online mode

Step5: import the data in online mode

2009-7-2

Page16, Total17

BTS3900 Configuration

Level: internal

The log above indicates that importing is successful.


Step6: edit the MML script
Use the UltraEdit tool to edit the exported file namedBTS3900 adjacent cell
above.
CommanADD CELL2GNC will be used to add adjacent cell. Its very to edit
the MML script with the UltraEdit tool in column mode.
Take care theBidirectional Adjacent CellandSingle directional Adjacent Cell!
For the theBidirectional Adjacent Cell, command ADD CELL2GNC should
be executed twice to add adjacent cell in both cell.
Step7: execute the MML script in batch
Log in the MML and execute the scriptBTS3900 adjacent cell in batch.

2009-7-2

Page17, Total17

You might also like