Professional Documents
Culture Documents
>
Data Sheet
SFP/XFP Transceivers
Small Form-Factor Pluggable Transceivers
Fiber optic/electrical
transceivers
SFP/XFP Transceivers
Small Form-Factor Pluggable Transceivers
Data Sheet
Specifications
FIBER OPTIC INTERFACES
Notes:
Commercial SFPs are designed to withstand temperatures between 0 -70 C (32-158 C)
Some of RADs SFPs are available in industrially hardened (H) versions, designed to withstand temperatures between
-40- 85 C (-40 -185 F).
The specified typical range may vary according to the specific product in which the SFP is used. For more information, refer to
the data sheet of the specific product.
Legend:
H industrially hardened SFP
D DDM calibration
ED external DDM calibration.
Wavelength,
Interface, Connector
Fiber Type
[nm],
Standards
Transmitter
Input Power
Output Power
[dBm]
[dBm]
Type
[m]
Typical Max.
Range
[min]
[max]
[min]
[max]
[km] [miles]
LED
-30
-14
-20
-14
1.2
LED
-30
-14
-20
-14
1.2
Laser
-28
-8
-15
-8
15
9.3
Laser
-28
-8
-15
-8
15
9.3
Laser
-28
-8
-15
-8
15
9.3
Laser
-28
-8
-15
-8
15
9.3
SFP-1
Fast Ethernet/STM-1, LC
multimode
SFP-1D
multimode
SFP-2
1310, 9/125
Fast Ethernet/STM-1, LC
single mode
SFP-2H
1310, 9/125
single mode
SFP-2D
1310, 9/125
single mode
SFP-2DH
1310, 9/125
single mode
SFP-3
1310, 9/125
Laser
-34
-10
-5
40
24.8
Fast Ethernet/STM-1, LC
single mode
SFP-3H
1310, 9/125
Laser
-34
-10
-5
40
24.8
single mode
G.957 L1.1 (STM-1)
Laser
-34
-10
-5
40
24.8
Laser
-34
-10
-5
80
49.7
industrially hardened
industrially hardened
SFP-3D
1310, 9/125
single mode
1550, 9/125
Fast Ethernet/STM-1, LC
single mode
SFP/XFP Transceivers
Small Form-Factor Pluggable Transceivers
Table 1. Fiber Optic Fast Ethernet/STM-1/STM-4 SFPs (cont.)
Ordering Name,
Wavelength,
Interface, Connector
Fiber Type
[nm],
Standards
Transmitter
Type
[m]
SFP-4D
1550, 9/125
single mode
Input Power
[dBm]
Output Power
[dBm]
Typical Max.
Range
[min]
[max]
[min]
[max]
[km] [miles]
-34
-10
-5
80
49.7
-28
-8
-14
-8
20
12.4
-28
-8
-14
-8
20
12.4
-28
-8
-14
-8
20
12.4
-28
-8
-14
-8
20
12.4
Tx 1310/Rx 1550,
100BaseBX10,
Laser
Fast Ethernet/STM-1,
(WDM)
LC
(single fiber)
G.957 (STM-1)
SFP-10B
Tx 1550/Rx 1310,
100BaseBX10,
Laser
Fast Ethernet/STM-1,
(WDM)
LC
(single fiber)
G.957 (STM-1)
SFP-10AD
Tx 1310/Rx 1550,
100BaseBX10,
Laser
(WDM)
(single fiber)
G.957 (STM-1)
SFP-10BD
Tx 1550/Rx 1310,
100BaseBX10,
Laser
(WDM)
(single fiber)
G.957 (STM-1)
SFP-14D,
1310, 62.5/125
Laser
-28
-14
-20
-14
0.5
0.3
multimode
G.957 S4.1
Laser
-28
-8
-15
-8
15
9.3
G.957 L4.2
Laser
-28
-8
-3
+2
80
49.7
Laser
-28
-8
-5
40
24.8
-28
-8
-5
40
24.8
-28
-8
-5
40
24.8
-28
-8
-5
40
24.8
-30
-8
+5
80
49.7
-30
-8
+5
80
49.7
internal calibration
SFP-15
1310, 9/125
STM-4, LC
single mode
SFP-16
1550, 9/125
STM-4, LC
single mode
SFP-18A
Tx 1310/Rx 1550,
Fast Ethernet/STM-1,
LC
(single fiber)
SFP-18B
Tx 1550/Rx 1310,
Fast Ethernet/STM-1,
LC
(single fiber)
SFP-18AED
Tx 1310/Rx 1550,
Fast Ethernet/STM-1,
(single fiber)
SFP-18BED
Tx 1550/Rx 1310,
Fast Ethernet/STM-1,
(single fiber)
SFP-19A
Tx 1490/Rx 1570,
Fast Ethernet/STM-1,
LC
(single fiber)
SFP-19B
Tx 1570/Rx 1490,
Fast Ethernet/STM-1,
LC
(single fiber)
SFP-24
850, 50/125
Fast Ethernet/STM-1,
Multimode
LC
850, 62.5/125
multimode
(WDM)
Laser
(WDM)
Laser
(WDM)
Laser
(WDM)
Laser
(WDM)
Laser
(WDM)
VCSEL
-25
-2
-10
-4
1.2
VCSEL
-25
-2
-10
-4
0.6
Data Sheet
Wavelength,
Interface, Connector
Fiber Type
[nm],
Standards
Transmitter
Input Power
Output Power
[dBm]
[dBm]
Type
[m]
Typical Max.
Range
[min]
[max]
[min]
[max]
[km] [miles]
VCSEL
-17
-9.5
0.55 0.3
VCSEL
-17
-9.5
0.55 0.3
VCSEL
-17
-9.5
0.55 0.3
VCSEL
-17
-9.5
0.55 0.3
Laser
-20
-3
-9.5
-3
10
6.2
Laser
-20
-3
-9.5
-3
10
6.2
Laser
-20
-3
-9.5
-3
10
6.2
Laser
-20
-3
-9.5
-3
10
6.2
SFP-5
850, 50/125
1000BaseSX,
Gigabit Ethernet, LC
multimode
SFP-5H
850, 50/125
1000BaseSX,
multimode
SFP-5D
850, 50/125
1000BaseSX,
multimode
SFP-5DH
850, 50/125
1000BaseSX,
multimode
SFP-6
1310, 9/125
1000BaseLX10,
Gigabit Ethernet, LC
single mode
SFP-6H
1310, 9/125
1000BaseLX10,
single mode
SFP-6D
1310, 9/125
1000BaseLX10,
single mode
SFP-6DH
1310, 9/125
1000BaseLX10,
single mode
SFP-7
1550, 9/125
Laser
-22
-3
+5
80
49.7
Gigabit Ethernet, LC
single mode
SFP-7D
1550, 9/125
Laser
-22
-3
+5
80
49.7
single mode
Laser
-22
-3
+5
80
49.7
Laser
-21
-3
-4
+4
40
24.8
Laser
-21
-3
-4
+4
40
24.8
Laser
-21
-3
-4
+4
40
24.8
Laser
-21
-3
-4
+4
40
24.8
industrially hardened
industrially hardened
1550, 9/125
single mode
1310, 9/125
Gigabit Ethernet, LC
single mode
SFP-8H
1310, 9/125
single mode
industrially hardened
SFP-8D
1310, 9/125
single mode
1310, 9/125
single mode
SFP/XFP Transceivers
Small Form-Factor Pluggable Transceivers
Table 2. Fiber Optic Gigabit Ethernet SFPs (cont.)
Ordering Name,
Wavelength,
Interface, Connector
Fiber Type
[nm],
Standards
Transmitter
Type
[m]
SFP-17A
Tx 1310/Rx 1490,
1000BaseBX10,
Laser
Gigabit Ethernet, LC
(WDM)
Input Power
[dBm]
Output Power
[dBm]
Typical Max.
Range
[min]
[max]
[min]
[max]
[km]
[miles]
-20
-3
-9
-3
10
6.2
-20
-3
-9
-3
10
6.2
-20
-3
-9
-3
10
6.2
-20
-3
-9
-3
10
6.2
(single fiber)
SFP-17B
Tx 1490/Rx 1310,
1000BaseBX10,
Laser
Gigabit Ethernet, LC
(WDM)
(single fiber)
SFP-17AD
Tx 1310/Rx 1490,
1000BaseBX10,
Laser
(WDM)
Internal calibration
(single fiber)
SFP-17BD
Tx 1490/Rx 1310,
1000BaseBX10,
Laser
(WDM)
Internal calibration
(single fiber)
SFP-20
1550, 9/125
Laser
-32
-8
+1
+5
120
74.5
Gigabit Ethernet, LC
single mode
SFP-20EDH
1550, 9/125
Laser
-30
-8
+1
+5
120
74.5
single mode
Laser
-24
-3
-5
40
24.8
-24
-3
-5
40
24.8
-24
-3
-5
40
24.8
-24
-3
-5
40
24.8
-24
-3
+5
80
49.7
-24
-3
+5
80
49.7
-24
-3
-5
40
24.8
-24
-3
-5
40
24.8
-24
-3
-5
40
24.8
Tx 1310/Rx 1490,
Gigabit Ethernet, LC
(WDM)
(single fiber)
SFP-21B
Tx 1490/Rx 1310,
Gigabit Ethernet, LC
Laser
(WDM)
(single fiber)
SFP-21AED
Tx 1310/Rx 1490,
external calibration
(single fiber)
SFP-21BED
Tx 1490/Rx 1310,
external calibration
(single fiber)
SFP-22A
Tx 1490/Rx 1570,
Gigabit Ethernet, LC
Laser
(WDM)
Laser
(WDM)
Laser
(WDM)
(single fiber)
SFP-22B
Tx 1570/Rx 1490,
Gigabit Ethernet, LC
Laser
(WDM)
(single fiber)
SFP-23A
Tx 1310/Rx 1550,
Gigabit Ethernet, LC
Laser
(WDM)
(single fiber)
SFP-23B
Tx 1550/Rx 1310,
Gigabit Ethernet, LC
Laser
(WDM)
(single fiber)
SFP-23AED
Tx 1310/Rx 1550,
external calibration
(single fiber)
Laser
(WDM)
Data Sheet
Wavelength,
Interface, Connector
Fiber Type
[nm],
Standards
Transmitter
Type
[m]
SFP-23BED
Tx 1550/Rx 1310,
Laser
Input Power
[dBm]
Output Power
[dBm]
Typical Max.
Range
[min]
[max]
[min]
[max]
[km]
[miles]
-24
-3
-5
40
24.8
(WDM)
external calibration
(single fiber)
SFP-28a
Laser
(WDM)
-20
-3
-9
-3
10
6.2
Laser
(WDM)
-20
-3
-9
-3
10
6.2
Laser
WDM)
-20
-3
-9
-3
10
6.2
Laser
(WDM)
-20
-3
-9
-3
10
6.2
internal calibration
SFP-47DH
1470, 9/125
G.694.2, CWDM
Laser
-24
-3
+5
80
49.7
single mode
grid compliant
(CWDM)
SFP-49DH
1490, 9/125
G.694.2, CWDM
Laser
-24
-3
+5
80
49.7
single mode
grid compliant
(CWDM)
SFP-51DH
1510, 9/125
G.694.2, CWDM
Laser
-24
-3
+5
80
49.7
single mode
grid compliant
(CWDM)
SFP-53DH
1530, 9/125
G.694.2, CWDM
Laser
-24
-3
+5
80
49.7
single mode
grid compliant
(CWDM)
Gigabit Ethernet, LC
SFP-28b
Gigabit Ethernet, LC
SFP-28AD
Gigabit Ethernet, LC, DDM,
internal calibration
SFP-28BD
Gigabit Ethernet, LC, DDM,
internal calibration,
extended temperature range
20 to 85 C (4 to 185 F)
internal calibration,
extended temperature range
20 to 85 C (4 to 185 F)
internal calibration,
extended temperature range
20 to 85 C (4 to 185 F)
internal calibration,
extended temperature range
20 to 85 C (4 to 185 F)
SFP/XFP Transceivers
Small Form-Factor Pluggable Transceivers
Wavelength,
Interface, Connector
Fiber Type
[nm],
Standards
Transmitter
Input Power
Output Power
[dBm]
[dBm]
Type
[m]
SFP-55DH
1550, 9/125
G.694.2, CWDM
Laser
single mode
grid compliant
(CWDM)
SFP-57DH
1570, 9/125
G.694.2, CWDM
Laser
single mode
grid compliant
(CWDM)
SFP-59DH
1590, 9/125
G.694.2, CWDM
Laser
single mode
grid compliant
(CWDM)
SFP-61DH
1610, 9/125
G.694.2, CWDM
Laser
single mode
grid compliant
(CWDM)
Typical Max.
Range
[min]
[max]
[min]
[max]
[km]
[miles]
-24
-3
+5
80
49.7
-24
-3
+5
80
49.7
-24
-3
+5
80
49.7
-24
-3
+5
80
49.7
internal calibration,
extended temperature range
20 to 85 C (4 to 185 F)
internal calibration,
extended temperature range
20 to 85 C (4 to 185 F)
internal calibration,
extended temperature range
20 to 85 C (4 to 185 F)
internal calibration,
extended temperature range
20 to 85 C (4 to 185 F)
Data Sheet
Wavelength,
Interface, Connector
Fiber Type
[nm],
XFP-1D
10 Gigabit Ethernet, LC, DDM,
Standards
Transmitter
Input Power
Output Power
[dBm]
[dBm]
Type
[m]
1310, 9/125
10GBASE-LR/LW
single mode
IEEE 802.3
Typical Max.
Range
[min]
[max]
[min]
[max]
[km]
[miles]
Laser
-14.4
+0.5
-8.2
+0.5
10
6.2
Laser
-14.4
+0.5
-8.2
+0.5
10
6.2
Laser
-24
-7
+4
80
49.7
Laser
-15.8 -1
-4.7
+4
40
24.8
Laser
-15.8 -1
-4.7
+4
40
24.8
VCSEL
-9.9
-7.3
-1
0.3
0.186
internal calibration
1310, 9/125
10 Gigabit Ethernet, LC, DDM, single mode
Internal calibration ,
industrially hardened
10GBASE-LR/LW
1550, 9/125
10 Gigabit Ethernet, LC, DDM, single mode
10GBASE-ZR/ZW
XFP-1DH
XFP-2D
IEEE 802.3
IEEE 802.3
internal calibration
1550, 9/125
10 Gigabit Ethernet, LC, DDM, single mode
XFP-3D
10GBASE-ER/EW
IEEE 802.3
internal calibration
1550, 9/125
10 Gigabit Ethernet, LC, DDM, single mode
Internal calibration ,
industrially hardened
10GBASE-ER/EW
850, 50/125
10 Gigabit Ethernet, LC, DDM, multimode
10GBASE-SR/SW
XFP-3DH
XFP-4D
internal calibration
IEEE 802.3
IEEE 802.3
-1
SFP/XFP Transceivers
Small Form-Factor Pluggable Transceivers
Wavelength,
Interface, Connector
Fiber Type
[nm],
XFP-5D-19
Standards
Transmitter
[m]
1562.23
10GBASE-ER/EW
Laser
(DWDM)
1561.42
10 Gigabit Ethernet, LC, DDM, (C-Band,
internal calibration
Channel 20),
9/125 single mode
10GBASE-ER/EW
Laser
IEEE 802.3
(DWDM)
1530.33
10GBASE-ER/EW
10 Gigabit Ethernet, LC, DDM, (C-Band,
IEEE 802.3
internal calibration
Channel 59), 9/125
single mode
XFP-5D-59
Output Power
[dBm]
[dBm]
[min]
Input Power
Type
Laser
(DWDM)
[max]
Typical Max.
Range
[min]
[max]
[km]
-15.8 -1
-4.7
+4
40
24.8
[miles]
-15.8 -1
-4.7
+4
40
24.8
-15.8 -1
-4.7
+4
40
24.8
Data Sheet
Ordering Name,
Standards
Cable Type
Impedance
Interface, Connector
(Attenuation)
SFP-9-GH
[]
[m]
[ft]
UTP, CAT.5
100
100
328
UTP, CAT.5
100
100
328
SFP-11
G.703, supports
Coaxial
75
135
442
CMI encoder/decoder
SFP-11PP
G.703, supports
CMI encoder/decoder
75
135
442
(12.7 dB)**
DIN 1.0/2.3
SFP-30
10/100/1000BaseT,
IEEE 802.3
UTP, cat. 5
100
100
328
SGMII Interface
Notes:
** With SFP-11/SFP-11PP, a 135m range is attainable when using RG59 B/U (at 78 MHz, in accordance with the square root
of frequency law).
Ordering Name,
Wavelength,
Interface, Connector
Fiber Type
[nm],
1310, 9/125
single mode
Input Power
[dBm]
Type
[m]
SFP-26D
Gigabit Ethernet/Fibre
Channel/Fast Ethernet/
STM-4/STM-1,LC, DDM,
internal calibration
Standards Transmitter
Laser
[min]
[max] [min]
[max]
[km]
[miles]
-18
(2.67 Gbps/
OC-48/FE)
15
9.3
-21
(2 x FC/GbE/1x FC
, STM-4/STM-1)
-5
Data Sheet
SFP/XFP Transceivers
Small Form-Factor Pluggable Transceivers
SUPPLIED ACCESSORIES
CBL-MINIBNC-BNC
Two adapter cables for converting mini
BNC connectors to regular BNC coaxial
connectors (for SFP-11)
127-100-08/12 Specifications are subject to change without prior notice. 19882012 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven, and the
product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders.
Ordering
CBL-MINIBNC/PP-BNC
Two adapter cables for converting mini
BNC Push-Pull connectors to regular BNC
coaxial connectors (for SFP-11/PP)
International Headquarters
24 Raoul Wallenberg Street
Tel Aviv 69719, Israel
Tel. 972-3-6458181
Fax 972-3-6498250, 6474436
E-mail market@rad.com