Issue 01 (2007-09-05)
6-1
2.
3.
Mandatory/ Mandatory
Optional
NOTE
A maximum of 32 Ater connection paths can be configured between the GOIUT and the GEIUT.
The Ater interface E1 that is configured with the semipermanent connection should not be configured
with the Ater connection path.
Prerequisite
l
The two subracks between which the Ater connection path is to be established are
configured.
The GEIUT/GOIUT in the two subracks between which the Ater connection path is to be
established is configured.
Preparation
NOTE
This parts describes how to configure the Ater connection path between the GMPS and the GTCS as well
as between the GEPS and the GTCS.
6-2
Issue 01 (2007-09-05)
Table 6-1 Example of data to be negotiated and planned for configuring the Ater connection
path between the GMPS and the GTCS
Parameter
Example
Source
BM Subrack No.
BM Slot No.
16
BM Port No.
TC Subrack No.
TC Slot No.
16
TC Port No.
Table 6-2 Example of data to be negotiated and planned for configuring the Ater connection
path between the GEPS and the GTCS
Parameter
Example
Source
BM Subrack No.
BM Slot No.
16
BM Port No.
TC Subrack No.
TC Slot No.
16
TC Port No.
Procedure
l
Configure the Ater connection path between the GMPS and the GTCS.
1.
NOTE
The configuration of the Ater connection path can be started only on the GEIUT/GOIUT.
2.
Issue 01 (2007-09-05)
6-3
3.
6-4
4.
5.
Click Finish. The configuration of the Ater connection path between the GMPS and
the GTCS is complete.
6.
Repeat 1 through 5 to add more Ater connection paths between the GMPS and the
GTCS.
Huawei Technologies Proprietary
Issue 01 (2007-09-05)
Configure the Ater connection path between the GEPS and the GTCS.
1.
NOTE
The configuration of the Ater connection path can be started only on the GEIUT/GOIUT.
2.
3.
Issue 01 (2007-09-05)
6-5
4.
5.
Click Finish. The configuration of the Ater connection path between the GEPS and
the GTCS is complete.
6.
Repeat 1 through 5 to add more Ater connection paths between the GEPS and the
GTCS.
----End
Mandatory/ Optional. When the GTCS is configured on the MSC side, you have to add an
Optional
Ater OML between the GMPS and the main GTCS.
NOTE
An active and a standby Ater OMLs are usually configured. The timeslot masks of the two links must
be the same.
The timeslot mask of an Ater OML must contain TS1 and at least four successive timeslots.
Prerequisite
6-6
The Ater connection path between the GMPS and the main GTCS is configured.
Issue 01 (2007-09-05)
Preparation
Table 6-3 Example of data to be negotiated and planned for adding an OML
Parameter
Example
Source
Timeslot Mask
TS1, TS2TS17
Procedure
Step 1 On the BSC6000 Local Maintenance Terminal, right-click a GEIUT in the GMPS. A shortcut
menu is displayed, as shown in Figure 6-7.
Figure 6-7 GEIUT shortcut menu
NOTE
The configuration of the Ater OML can be started only on the GEIUT/GOIUT in the GMPS.
Step 2 Choose Add Ater OML. A dialog box is displayed, as shown in Figure 6-8.
Issue 01 (2007-09-05)
6-7
6-8
Issue 01 (2007-09-05)
NOTE
When the total number of the GMPS and GEPS is not greater than two, TS1 and 16 successive timeslots
must be configured.
When the total number of the GMPS and GEPS exceeds two, 31 timeslots from TS1 to TS31 must be
configured.
Step 4 Set the parameters according to the data listed in Table 6-3.
Step 5 Click OK.
Step 6 Click Finish. The configuration is complete.
----End
Mandatory/ Optional. When the GTCS is configured on the MSC side, the Ater signaling link
Optional
must be configured.
NOTE
The rate of an Ater signaling link can be 64 kbit/s or 2 Mbit/s, but only one rate type can be selected.
Each GEIUT/GOIUT in the GTCS can be configured with up to sixteen 64 kbit/s Ater signaling links.
Each GEIUT/GOIUT in the GTCS can be configured with up to eight 2 Mbit/s Ater signaling links.
The maximum bandwidth is 4 Mbit/s.
The rate of the Ater signaling link on the Ater interface must be the same as that of the SS7 signaling
link on the A interface.
A total number of eight 2 Mbit/s signaling links and 2 Mbit/s SS7 signaling links can be configured
for the GMPS or GEPS where the Ater connection path is located.
Prerequisite
l
The Ater connection path between the GMPS or GEPS and the GTCS is configured.
Preparation
NOTE
Issue 01 (2007-09-05)
This part describes how to configure the 64 kbit/s Ater signaling link.
For details about the configuration of the 2 Mbit/s signaling link, refer to .
6-9
Table 6-4 Example of data to be negotiated and planned for adding an Ater signaling link
Parameter
Example
Source
Rate Type
64 kbit/s
Satellite Flag
No
Timeslot Mask
TS18
Procedure
Step 1 On the BSC6000 Local Maintenance Terminal, right-click a GEIUT in the GTCS. A shortcut
menu is displayed, as shown in Figure 6-10.
Figure 6-10 GEIUT shortcut menu
NOTE
The configuration of the Ater signaling link can be started only on the GEIUT/GOIUT in the GTCS.
Step 2 Choose Add Ater Signaling Link. A dialog box is displayed, as shown in Figure 6-11.
6-10
Issue 01 (2007-09-05)
NOTE
Only one timeslot can be configured for the added 64 kbit/s Ater signaling link.
Issue 01 (2007-09-05)
6-11
Step 4 Set the parameters according to the data listed in Table 6-4.
Step 5 Click OK.
Step 6 Click Finish. The configuration is complete.
----End
2.
Mandatory/ Mandatory
Optional
Prerequisite
The GEIUA/GOIUA in the GTCS is configured.
Preparation
Table 6-5 Example of data to be negotiated and planned for configuring an A interface E1
Parameter
Example
Source
Subrack No.
Slot No.
20
Port No.
Start CIC
Procedure
Step 1 On the BSC6000 Local Maintenance Terminal, right-click a GEIUA in the GTCS. A shortcut
menu is displayed, as shown in Figure 6-13.
6-12
Issue 01 (2007-09-05)
NOTE
The configuration of the A interface E1 can be started only on the GEIUA/GOIUA in the GTCS.
Step 2 Choose Configure A Interface E1. A dialog box is displayed, as shown in Figure 6-14.
Figure 6-14 Configuring an A interface E1
Step 3 Click Add. A dialog box is displayed, as shown in Figure 6-15. The default tab page is A
Interface E1 Attributes.
Issue 01 (2007-09-05)
6-13
Step 4 Set the parameters according to the data listed in Table 6-5.
NOTE
On the CIC Attributes tab page, retain the default settings or modify them according to your requirements.
Mandatory/ Mandatory
Optional
NOTE
6-14
Each GEIUT/GOIUT in the GTCS can be configured with up to sixteen 64 kbit/s SS7 signaling links.
Each GEIUT/GOIUT in the GTCS can be configured with up to eight 2 Mbit/s SS7 signaling links.
The maximum bandwidth is 4 Mbit/s.
The rate of the SS7 signaling link must be the same as that of the Ater signaling link.
A total number of eight 2 Mbit/s Ater signaling links and 2 Mbit/s SS7 signaling links can be configured
for the GMPS or GEPS where the Ater connection path is located.
Huawei recommends that all the 2 Mbit/s SS7 signaling links have the same number of timeslots to
achieve the optimal load sharing effect.
Issue 01 (2007-09-05)
Prerequisite
l
The GXPUM is configured in the GMPS or GEPS that connects with the GTCS. The Ater
connection path is configured.
Preparation
NOTE
This part describes how to configure the 64 kbit/s SS7 signaling link.
For details about the configuration of the 2 Mbit/s signaling link, refer to .
Table 6-6 Example of data to be negotiated and planned for adding an SS7 signaling link
Parameter
Example
Source
Rate Type
64 kbit/s
A Subrack No.
A Slot No.
21
A Port No.
TS10
A Timeslot Mask
TS1
SLC
SLC Send
Procedure
Step 1 On the BSC6000 Local Maintenance Terminal, right-click a GEIUA in the GTCS. A shortcut
menu is displayed, as shown in Figure 6-16.
Figure 6-16 GEIUA shortcut menu
Issue 01 (2007-09-05)
6-15
The configuration of the SS7 signaling link can be started only on the GEIUA/GOIUA in the GTCS.
Step 2 Choose Configure SS7 Signaling Link. A dialog box is displayed, as shown in Figure 6-17.
Figure 6-17 Configuring the SS7 signaling link
Step 3 Click Add. A dialog box is displayed, as shown in Figure 6-18. The default tab page is
MTP2.
6-16
Issue 01 (2007-09-05)
Step 4 Set the parameters according to the data listed in Table 6-6.
NOTE
The number of timeslots on the A interface must be the same as that on the Ater interface.
Issue 01 (2007-09-05)
6-17
Step 6 Set the parameters according to the data listed in Table 6-6.
Step 7 Click OK.
Step 8 Click Finish. The configuration is complete.
----End
6-18
1.
2.
3.
Issue 01 (2007-09-05)
Mandatory/ Optional. The PCU should be configured when the BSC offers PS services.
Optional
NOTE
Prerequisite
None.
Preparation
Table 6-7 Example of data to be negotiated and planned for adding a PCU
Parameter
Example
Source
PCU No.
PCU Name
PCU 1
Procedure
Step 1 On the BSC6000 Local Maintenance Terminal, right-click BSC6000. A shortcut menu is
displayed, as shown in Figure 6-20.
Figure 6-20 Shortcut menu in the management tree
Step 2 Choose Configure PCU. A dialog box is displayed, as shown in Figure 6-21.
Issue 01 (2007-09-05)
6-19
Step 4 Set the parameters according to the data listed in Table 6-7.
Step 5 Click OK.
Step 6 Repeat Step 1 through Step 5 to add more PCUs.
6-20
Issue 01 (2007-09-05)
Prerequisite
l
Preparation
Table 6-8 Example of data to be negotiated and planned for configuring a Pb interface E1
Parameter
Example
Source
Subrack No.
Slot No.
23
Port No.
Transfer Mode
Terrestrial Transmission
Start PCIC
PCU No.
Procedure
Step 1 On the BSC6000 Local Maintenance Terminal, right-click a GEIUP in the GMPS. A shortcut
menu is displayed, as shown in Figure 6-23.
Figure 6-23 GEIUP shortcut menu
Issue 01 (2007-09-05)
6-21
The configuration of the Pb interface E1 can be started only on the GEIUP/GOIUP in the GMPS or GEPS.
Step 2 Choose Configure Pb Interface E1. A dialog box is displayed, as shown in Figure 6-24.
Figure 6-24 Configuring a Pb interface E1
Step 3 Click Add. A dialog box is displayed, as shown in Figure 6-25. The default tab page is Pb
Interface E1 Attributes.
6-22
Issue 01 (2007-09-05)
Step 4 Set the parameters according to the data listed in Table 6-8.
NOTE
On the CIC Attributes tab page, retain the default settings or modify them according to your requirements.
Mandatory/ Optional. A Pb signaling link should be configured when the BSC is configured
Optional
with a PCU.
NOTE
Prerequisite
The Pb interface E1 is configured.
Issue 01 (2007-09-05)
6-23
Preparation
Table 6-9 Example of data to be negotiated and planned for configuring a Pb signaling link
Parameter
Example
Source
Port No.
Timeslot No.
Procedure
Step 1 On the BSC6000 Local Maintenance Terminal, right-click a GEIUP in the GMPS. A shortcut
menu is displayed, as shown in Figure 6-26.
Figure 6-26 GEIUP shortcut menu
NOTE
The configuration of a Pb signaling link can be started only on the GEIUP/GOIUP in the GMPS or GEPS.
Step 2 Choose Configure Pb Signaling Link. A dialog box is displayed, as shown in Figure 6-27.
6-24
Issue 01 (2007-09-05)
Step 4 Set the parameters according to the data listed in Table 6-9.
Step 5 Click OK.
Issue 01 (2007-09-05)
6-25
6-26
Issue 01 (2007-09-05)