Importance Factor
Since the building is an office we will be using standard occupancy for Importance Factor.
I = 1.00
Since soil parameters are unknown, soil profile type D will be assumed.
SD = 600 ft/sec to 1200 ft/sec
Since the fault is neither active nor inactive, Type B will be assumed.
Type B
Near-Source Factor
Ground response coefficient for Zone 4 having soil profile type D will be used for the structure.
Ca = 0.44Na , Cv = 0.64Nv
Since: Na = 1.0 , Nv = 1.0
Therefore: Ca = 0.44 , Cv = 0.64
Since the structure is composed of Moment resisting frames to resist lateral loads, response
modification factor for steel or concrete special moment resisting frames will be used.
R = 8.5
Base shear
Min. Permitted
Value
Max. Value
BASE SHEAR = 4175.18KN
Formula
0.1205W
BASE SHEAR
Seismic Dead Load (W)
34648.794KN
Total
4175.18KN
0.0484W
34648.794KN
1677.002KN
0.129W
34648.794KN
4469.694KN