You are on page 1of 41

Alarm Handling

www.huawei.com

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Clock Reference Abnormal


Alarm
Possible Causes:

Faulty clock module.

Abnormal clock of the transmission link.

Abnormal upper level clock reference.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

BBU CPRI Interface Error

Possible Causes:

The optical module on the CPRI port of the BBU is faulty or not
installed securely, or the cable connection on the CPRI optical
module is not ready.

The CPRI interface board in the BBU is faulty.

The lower-level RF unit is not powered on.

The optical module or connector of the lower-level RF unit is


improperly installed or the optical module is faulty.

The lower-level RF unit is faulty.

The optical link between the BBU and the lower-level RF unit is
faulty.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Board Communication Alarm

On the DDPU:

Possible Causes

The corresponding RF module is not installed.

The communication interface board in the RF front


module is faulty.

On the DEMU:

Possible Causes

The DEMU is faulty, not inserted securely, or configured in


different slot.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

DUP Unit Hardware Fault

Possible Causes

Faulty DUP Unit hardware.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Board Type Mismatch

Appeared on the DDPU board

The BTS detects that the configured board type is


inconsistent with the actual board type.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Diversity Receive Channel


alarm
Possible Causes

The RF cable connected to the main receive port on


the DTRU is loose or damaged.

The DTRU is damaged.

The cable between the cabinet top and antenna is


loose or damaged

The DDPU is damaged.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

CDU Band Mismatch ARFCN


Alarm

Appear on the DDPU

Possible Causes

The CDU frequency band does not match with the


TRX frequency.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

GSM Cell out of Service

Possible Causes

Manual blocking: The cell or BCCH TRX is manually blocked.

Other OM operations: manual reset of the BTS or cell and


automatic BTS reset because of dynamic data configuration
(for example, modify Main BCCH frequency).

BTS power failure: There is no power supply to the BTS.

The board which contain the BCCH is faulty

Level 2 VSWR on the BCCH path for the Cell.

Software of the board is older than others.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Level 1 VSWR Alarm&Level 2 VSWR Alarm

Possible Causes

The connections of the antenna feeder transmit


channel are faulty.

The DUP Unit hardware is faulty.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Load Power Off Alarm

Possible Causes

When the DC power supply fails, or the temperature


inside the cabinet is too high, the MCU or the PMU of
the BTS power off the some of the less important
devices.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

PSU Comm. Alarm

Possible Causes

The communications between the PSU and the PMU


in the power system fails.

The PMU detects that the configured power module


is out of position.

The corresponding PSU is faulty.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

PSU Illegal Alarm

Possible Causes

The configuration data does not contain PSU data


while a PSU is physically inserted.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

PSU shutdown alarm

Possible Causes

No AC input.

The PSU is faulty

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Radio link prompt alarm

Possible Causes

Sub link 0:Abnormal channel activation alarm

Sub link 1:Abnormal channel release alarm

Sub link 2:No traffic alarm

Sub link 3:Power level imbalance between uplink and


downlink alarm

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

LAPD Alarm

Appear on BTS 3012

The transmission between the BSC and the BTS is


faulty.

The main control board or the RF unit is faulty

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Radio Signaling Link


Disconnected
Appear on BTS 3900

Possible Causes

The transmission between the BSC and the BTS is


faulty.

The main control board or the RF unit is faulty.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

RF Unit Maintenance Link


Failure
Possible Causes

The CPRI link between the current-level RF unit and


the BBU or upper-level RF unit is broken.

The RF unit is not powered on or running improperly.

The RF unit hardware is faulty.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

RF Unit RX Channel Fault

Possible Causes

The RF connections at the diversity RX port of the


TRX are loose or broken.

The TRX is damaged.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

RF Unit VSWR Threshold


Crossed
The installation of jumpers does not comply with the

planning.

The feeder connector on the antenna port is loose or


waterlogged.

The feeder connected to the antenna port of the RF


unit is bent, deformed, or damaged.

The VSWR detection circuit of the RF unit is faulty.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

TRX Baseband FH Abnormal Alarm

Possible Causes

Faulty TRX in the FH group.

The BBH is not configured correctly.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

TRX Close HPA Alarm

Possible Causes

The internal temperature of the BTS basic cabinet


reaches 52C.

The temperature detection circuit is faulty.

There is VSWR alarms on which of the TRX is


connected.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

TRX communication alarm

Possible Causes

The TRX is uninstalled, manually reset or powered


down.

The TRX is damaged.

The DTMU is damaged.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

TRX Hardware Critical Alarm

Appear on BTS 3012

Possible Causes

The hardware of the TRX running abnormal.

The hardware of the TRX is faulty.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

TRX Manually Blocked

Possible Causes

A TRX is manually administrative blocked

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

GSM Cell Manually Blocked

Possible Causes

A GSM cell is manually blocked.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

E1/T1 Local Alarm

Appear on BTS 3012

Possible Causes

Incorrect settings of the DIP switch of the BTS

Transmission link failure over the Abis interface

Transmission link failure between the BTS and the


BSC

Faulty TMU

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

E1/T1 Alarm Indication Signal

Appear on BTS 3900

Possible Causes

Incorrect settings of the DIP switch of the BTS

Transmission link failure over the Abis interface

Transmission link failure between the BTS and the


BSC

Faulty TMU

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

E1/T1 Loopback

Possible Causes

The user sets the local or remote loopback on the


E1/T1 link.

The E1/T1 physical loopback is performed.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

E1/T1 remote Alarm

Possible Causes

The transmission link is not available.

The settings for the DIP switches of the BTS are not
correct.

The hardware is faulty.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Cell PS Service Faulty

Cell is down

Site is down

Cell is not configured on the PCU

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Monitoring Device Maintenance Link


Failure

Appear on BTS 3900

Appear on the FMU or the EMU

Possible causes

The monitoring devise is connected on the wrong position


(cabinet/subrack/slot)

The cable connection from the BBU to the monitoring


device is faulty

The monitoring device is faulty

The BBU is faulty

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

E1/T1 Alarm Indication Signal

Appeared on the Electrical interface boards

Possible causes:

E1 is down

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

E1/T1 Excessive Bit Error


Rate
Appear on the electrical interface boards

Possible causes:

Bit error rate on the E1

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

SDH/SONET Tributary Alarm Indication


Signal

Appear on the Optical interface boards

Possible causes:

E1 is down

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

SDH/SONET Tributary Excessive Slip


Frames

Appear on the Optical interface boards

Possible causes:

Bit error rate on the E1

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Board unavailable

Possible causes:

Faulty hardware

Board manually reset

Board manually switchover

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

M3UA destination Entity Route


Unavailable
Possible causes:
One signaling link entity is down, due to links down from
TE or the switch is isolated from core side

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

OMU hardware fault


Possible causes:
Faulty Ethernet cable on one or more ports on the OMU
Faulty Ethernet Port

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.

Board Hardware Fault

Appear on the BSC

Possible causes:

The clock component is faulty.

The chip self-test is faulty.

The flash component is faulty.

The power component is faulty.

The backplane is faulty.

Copyright 2009 Huawei Technologies Co., Ltd. All rights reserved.