You are on page 1of 1

Comparision with Conventional floor

Sr Description

Conventional Floor

FIBERMESH FLOOR

Significance

1 Reinforcment Laying
and tying

200-250 Kg per day with 2 One/Two person at the batching


Bar benders 2 Helpers ( 10 plant or at the mixer. Cutting bags
hrs) for lesser diameter
and dosing
else varies

Saving in time and labour gives early


handover and cost saving

2 Cover block

1 no of 50 mm thick
Required per sqm

Not required

Saving in time and cost

3 Inspection

Inspection required after


reinforcement laying

No inspection required Dramix


Fibers mix homogenously in
concrete due to gluing technlogy

Work can be done with minimum


supervision. Dramix fibers are
engineered to suit your local needs

4 Conecrete pouring

Truck mixer or bag mixer


has to be loacted beyond
the flooring area

Mixer can go to pouring site as


there is no reinforcement

Saving in lead time as distance


between mixer and actual site is
reduced

5 Screed vibrator
6 Troweling
7 VDC (Varies)
8 Tensile strength

Same
Same
Same
415-500 N/mm ^2

Same
Same
Same
Min 1050 N/MM^2

9 Network

12mtrs per Mtr Square

Min 360 Mtr per Square Meter

More the netwrok better the


performance

10 Reinforcment

At Particular Level

Throughout the section

Throughout reinforcment gives


excellent crack control and
redistribution of loads

11 Failure mode

Brittle

Ductile

Better post carck behaviour better


post crack strength Ftcm

Higher tensile strength higher crack


control