You are on page 1of 4
Diesel Generator set QSK60 series engine 1600kVA - 2250kVA 50 Hz Data Center Continuous Cummins Power Generation commercial generator sets are fully integrated power generation systems providing optimum performance, reliability and versatility for Data Center applications. Data Center Continuous (DCC) - Applicable for supplying power continuously toa constant or varying electrical load for Unlimited hours in a data center application. Uptime Compliant - Meets the requirement of a Tier Ill and IV data center site by being rated to run for unlimited hours of operation when loaded to 'N’ demand for the engine generator set. ‘Cummins® heavy-duty engine - Rugged 4-cycle industrial diesel delivers reliable power, low emissions and fast response to load changes. Permanent magnet generator (PMG) - Offers enhanced motor starting and fault clearing short circuit capably. Alternator - Several alternator sizes offer selectable motor starting capability with low reactance 2/3 pitch windings; low waveform distortion with non-linear loads, fault clearing short-circuits capability, and class F or H insulation, Control system - Standard PowerCommand” electronic control provides total system integration including remote start/stop, precise frequency and voltage regulation, alarm and status message display, AmpSentry protection, ‘output metering, auto-shutdown, Cooling system - Standard integral set- mounted radiator system, designed and tested for rated ambient temperatures, simplifies facility design requirements for rejected heat. Warranty and service - Backed by a ‘comprehensive warranty and worldwide distributor network. lEmissions Jcomptiance soe ra Lutt- Me kva(umn leu stage _|Data shoots 61760 bse | 1600(1280) [2a TALut [Dst9-ceGK-0c {©2000 05 [1675 1500) sve-0eGK DG {©2000 bse [1425 (1460) [2a TALut_[Ds50-ceGKDC ‘e2280 05 _| 20007850) sse-ceGK DG ©2500 psa [7250 (1600) [aq TALut_[Ds50-ceGKDC ‘Our energy working for you.” Generator set specifications Goverror regulation cass 180 8526 G2 Voltage equation. no load to fulllbad = 0.5% Random voltage variation 0.5% Frequency regulation Tsochronous Random frequency variation 0.25% EMCcompatbilty Engine specifications BS EN 6100064 /BSENGIOOOGD Design 4 cycle, Vblack, turbo charged and low temperature after-cooled Bore 158.8mm 6.25in) ‘SHORE ¥90.0mm 7.48;n) Displacement 60.2 G67Sin», ‘Gylinder block ‘Cast iron 60°V Te eyinder Battery capacity 72200 amps at ambient temperature OF to 32°F [16 "O10 Battery charging altemator 40 amps ‘Starting voltage 24- volt negative ground Fuelsystem Direct injection Fuel iter “Tripleelement, spinon fuel fiters with water separator ‘Aircleaneriype Dry replaceable element Lube ol fiter Ya) Four spit-on, combination ful Tow and bypass fters ‘Standard cooling system “04°F ($0°O) ambient radiator Alternator specifications Design Brushless, 4 pole, dip prootrevoling field ‘Stator 273 pitch Rotor Direct coupled by flexible ise Insulation stem ‘Glass H Standard temperaturorice 160" standby Exciterype PMG (Permanent magnet generator) Phasorotation AU.8 0. CW) ‘Atemator cooing ‘AC waveform totalharmnonic starion “Telephone influence factor (TF) Direct drive centrifugal Blowerfan No load <1.5%, Non dstoring balanced inear load <5 ~= 5086 per NEMA MGI-22.43 Telephone harmonic factor THA <3% Available voltages 50 Hs line~ neutral / ine ine * 7207360 + 19057900 + 200/400 + 34016900 2 2401488 + 381016000 * 254/40 + 6350/1000 Tote: Consu factor fora vakages Generator set options Engine Aiternator Warranty Data Center Options Creavy duty air fiter Ch. Aterator heater 18 yeas for standby ErAitomatic ol make op DiWatelackethter «EL nighhurlelty station sppleaten Som 2200 1 Exciter votage regulator PMG) 2yearsfor prime application © Redundant electrical starters ‘best batery diode system Cooling Control panel Silencer 1D Closed crank ventilation Anitreeze 50/50 (Etyiene 03 poieman circuit breaker 29d attention crcl system syeo) 14 pote man ccut breaker Silencer 1 di'samplng vale 1.25 dB residential delivered loose 1D Propylene glycol coolant 1D Triplex fel fiters 1D Customized testing Note: Some options may not be available on all models - consut factory for availabilty. Data Center options are available through RF with the Custom Applications Group and could result in aditional eadtimes, Please consult withthe Custom Applications Group 10 understand feasibiy ‘Our energy working for you.” ssrrcraKoosoawe ai ‘cumminspowercom Control system PCC 3201 ‘The PowerCommand™ 3201 Control is a microprocessorbased generator set monitoring, and ‘control system, The control provides an operator interface to the genset, digital voltage regulation, digital governing and ‘generator set protective functions. ‘The PowerCommand™ 3201 generator set control is suitable for use on a wide range of generator sets in nonparalleling and paralleling applications. ‘The PowerCommand™ Control can be configured for any frequency, voltage and power connection ‘configuration from 120 to13,800 VAC for for S0Hz or 60Hz operation, Power for the control is derived from the generator set starting batteries. The control functions over a voltage range from 8VDC to 35VDC. Major Features * Digital Full Authority Electronic Engine Controls for Cummins HPI-PT fuel systems. * Digital Voltage Regulation with 3-phase sensing. ‘+ AmpSentry™ Protection for true alternator ‘overcurrent protection. + Analog and Digital AC Output Metering * Battery Monitoring System to sense and warn ‘against aweak battery condition, * Digital Alarm and Status Message Display. * Generator set Monitoring: Displays status of all critical engine and alternator generator set functions. + Smart Starting Control System: Integrated fuel ramping to limit black smoke and frequency overshoot + Advanced Serviceabilty using InPower, a PC-based software service tool Control system Includes all functions to locally or remotely start and stop, and protect the generator set. Control switch ~ RUN/OFF/AUTO + OFF mode-the generator set is shut down and cannot be started ‘+ RUN mode -the generator set will execute its start sequence, = AUTO mode - the generator set can be started with a start signal from a remote device. ‘Our energy working for you. ‘e2013Curmins omer Gmmaton he | SS17-CPOK-OCHD Res 1 LED Indicating Lamps— includes LED indicating lamps for the following functions: + Notin-auto mode * Common wiring * Shutdown + Remote start command + Panel lamps and switch * Operator panel can be illuminated by a series of high-intensity LED Lamps + Fault Reset Switch allows the operator to reset the ‘control after a warning or shutdown condition + Emergency Stop Switch - immediate shut down of the generator set on operation Base Engine Protection * Overspeed shutdown * Low Oil Pressure Warning / Shutdown * High Engine Temperature Warning / Shutdown * Underspeed / Sensor Fail Shutdown + Fail to Start / Fail to Crank * Low / high battery voltage Options 1 Integrated PowerCommand digital parallaling controls 10 Key type mode selector switch 1D Exhaust temperature monitoring 1D PowerCommandnetwork 1D Alternator temperature alarm(s). 10 Refer to the PowerCommand Controls Technical Bulletin for detailed information ($1444b) ‘cumminspowercom ‘Tis outine drawing isto provide representative configuration details for Model series only ‘See respective model data sheet forspecific model outine drawing number. Do not use for installation design Dim “a” Dim Dim “or [Set Weight [Set Weight» Model mm mm mm dry kg lwet kg '¢1760 De. et75 [240 [sage 15072 15736 ‘€2000 DS irs [2286 [2597 14649 rs152 ‘2000 D5e. irs [aaoa [sage 15072 6258) (€2250 DS irs [2286 [2597 75510 715366 '€2500 DSA (airs [eae [site 76690 ret * Note: Weights represent a set with standard features, See oulne drawings for weighs of other conigurations Codes and standards Tiron sis pad ao nal pone apa westii, SiC Ree Seaanacietn | novorsamee eras Sins age ens Ti grrr owe "i grata nena CE wes sso8528 Tiny in Oooo renten ‘Cummins Power Generation Europe, 1; Middle East an Aron Ameria sala Pace Wan Pat coarse tatoo vue NE to oncuan Rua 47.01 Mestn tarwoate eae S40 USA 17 orate Kent cri oF United Kinga Prone 12514300 Siaeore 05699 Phone te 8500 Favre se Sean Prove 2208 Fav sat toe Faveseatr 28 ‘ur energy working or your | stand {0 Curenay warng yo are adeno Can Powe Geran. te company, produ, oer nares nay be bade servos mars oo. Speen suelo hang wna rte ‘cumminspowercom SsircroRoI ANE RIG

You might also like