MOP FTR ERICSSON Domain v.

1
Alarm List

N
o
1
2
3
4
5
6
7

SpecificProblem

ALARM SLOGAN

RADIO X-CEIVER ADMINISTRATION MANAGED


OBJECT FAULT
RADIO X-CEIVER ADMINISTRATION MANAGED
OBJECT FAULT
RADIO X-CEIVER ADMINISTRATION MANAGED
OBJECT FAULT
RADIO X-CEIVER ADMINISTRATION MANAGED
OBJECT FAULT
RADIO X-CEIVER ADMINISTRATION MANAGED
OBJECT FAULT
RADIO X-CEIVER ADMINISTRATION MANAGED
OBJECT FAULT
CELL LOGICAL CHANNEL AVAILABILITY SUPERVISION

BTS INTERNAL

Alarm Detailed Solution For The Alarm (Step by Step)


-

RXASP:MO=RXOTG-XXX; (Check alarm)

OML FAULT
PERMANENT FAULT
LOCAL MODE
RF PERFORMANCE
TX/RX Communication
Fault
-

RXCDP:MO=RXOTG-XXX; (Check Configured)

RXMSP:MO=RXOTG-XXX, SUBORD; (Check CF config)

BLSTATE
o NOOP = Not Operation
o OPER = Operation

Note : Status CF yang NOOP tidak bisa di lakukan FTR


-

RXMFP:MO=RXOCF-XXX; (Check internal alarm)


Setalah di ketahui internal alarm bisa langsung di check di Fault Code
(terlampir)
Setelah di ketahui alarm dan CF OPER, maka tinggal lakukan proses FTR
dengan cara Riset NODE / CF dengan command :
RXBLI:MO=RXOTG-XXX,SUBORD,FORCE;

RXESE:MO=RXOTG-XXX,SUBORD;
RXESI:MO=RXOTG-XXX,SUBORD;
RXBLE:MO=RXOTG-XXX,SUBORD;

Note : Tools Terlampir


-

Setelah semua selesai maka bisa dilihat status site nya. Dan apabila setelah
di riset masih tidak bisa clear juga langsung bisa di assign TT ke BO atau ke
team dispatcher.