Professional Documents
Culture Documents
Desalination
plant
Irrigation system
Coagulation
Raw water
pumping station
Pump specific protections help to maintain disturbancefree operating time in a process. The protection functions
indicate if the pre-defined process conditions change. If
the flow or pressure exceeds defined process limits, the
appropriate alarm is generated. For example, using this
function can help prevent a pump dry run.
Inflow
pumping
station
Pressure boosting
station
Pumping station
Membrane treatment
Wastewater
pumping
station
UV light treatment
Screening
Active carbon
filtration
Ozone treatment
Pre-aeration
Contact basin
Sand filtration
Clarification
Preliminary
sedimentation
Aeration
Final sedimentation
Humus
Sludge
digestion
Sludge drying
Catalyst
Gas-fired power
plant
24 V DC input
Relay outputs (2 RO)
Analog and digital
extensions
Digital inputs (6 DI)
Digital inputs/outputs
(2 DI/O)
Analog inputs (2 AI)
Analog outputs (2 AO)
Modbus/drive-to-drive link
Safe torque off (STO)
User interface
(PC tools, control panel)
Motor connection
Removable memory unit
Communication
options
H = height
W = width
D = depth
D
W
Dimensions
Frame
size
Height
1)
mm
A
B
C
D
E0
E
G1
G2
364 (518)
380 (542)
567
567
602
700
1462 (1560)
1662 (1710)
mm
3)
3)
219
297
298
298
376
465
505 (515)
505 (515)
mm
3)
3)
94
101
166
221
276
312
305 (329)
305 (329)
Weight
kg
3)
3)
3.2
5.4
15.6
21.3
34
67
161 (191)
199 (229)
3)
3)
Notes
All dimensions and weights are without additional options.
1)
Height is the maximum measure without clamping plates. In A and
B frames the external C3 EMC-filter (height with filter in brackets).
EMC-filter is internal in frames C, D, E0, E, G1 and G2.
2)
Total depth with control panel
3)
With +H381 optional cabling panel
Mains connection
Voltage and power
range
Frequency
50 to 60 Hz 5%
Voltage
Output frequency
Motor control
Environmental limits
Degree of protection
Ambient temperature
1.1
1.1
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
355
400
450
500
Installation altitude
Relative humidity
Contamination levels
2 analog outputs
2 bidirectional digital
I/Os
6 digital inputs
0 to 20 mA
24 V logic levels, maximum 200 mA total output
current
24 V logic levels
2 relay outputs
Modbus/Drive to drive
link
I/O extensions
Icont
I max
Type designation
Frame
(A)
(A)
(order code)
size
ACQ810-04-02A7-4/2*
ACQ810-04-03A0-4
ACQ810-04-03A5-4/2*
ACQ810-04-04A9-4/2*
ACQ810-04-06A3-4/2*
ACQ810-04-08A3-4/2*
ACQ810-04-11A0-4/2*
ACQ810-04-14A4-4/2*
ACQ810-04-021A-4/2*
ACQ810-04-028A-4/2*
ACQ810-04-035A-4
ACQ810-04-040A-4/2*
ACQ810-04-053A-4/2*
ACQ810-04-067A-4/2*
ACQ810-04-080A-4/2*
ACQ810-04-098A-4
ACQ810-04-138A-4
ACQ810-04-162A-4
ACQ810-04-203A-4
ACQ810-04-240A-4
ACQ810-04-286A-4
ACQ810-04-377A-4
ACQ810-04-480A-4
ACQ810-04-570A-4
ACQ810-04-634A-4
ACQ810-04-700A-4
ACQ810-04-785A-4
ACQ810-04-857A-4
A
A
A
A
A
B
B
B
C
C
C
C
D
D
D
E0
E0
E
E
E
E
G1
G1
G1
G1
G2
G2
G2
UN=400 V U N=230 V
Motor connection
Motor types
I 2N
(A)
0.37
0.55
0.75
1.1
1.5
2.2
3
5.5
7.5
11
15
18.5
22
2.7
3
3.5
4.9
6.3
8.3
11
14.4
21
28
35
40
53
67
80
98
138
162
203
240
286
377
480
570
634
700
785
857
3
4.4
5.3
3.6
4.8
7.0
6
8.8
8
10.5
10.5 13.5
14
16.5
18
21
25
33
30
36
44
53
50
66
61
78
78
100
94
124
103 138
144 170
202 282
225 326
260 326
290 348
387 470
500 560
580 680
650 730
710 850
807 1020
875 1100
The last number in type code (4 or 2) refers nominal supply voltage UN.
Select number 4 when U N is 400 V and number 2 when UN is 230 V.
Protection functions
Over/undervoltage controller
Motor short-circuit protection
Input phase-loss detection (both motor and line)
Overcurrent protection
Drive temperature/overload controller
Power limits
Motor thermal protection
Product compliance
Conformity to standards CE, cUL, UL, CSA, GOST-R, C-Tick
Harmonics
IEC/EN 61000-3-12
EMC (according to
EN 61800-3)
Functional safety
PC tools
DriveStudio
DriveSPC
Contact us