Measuring Temperatures on Substrates/Materials
Using Psychrometer to Determine Dew Point
Detecting Residual Oil on Cleaned Surfaces
Measuring Pressure of Air/Abrasive Flow at Nozzle
Other Training Courses Tour SSPC Online More from SSPC
Using the current edition of SSPC-VIS 1 Standards to Detect Level
of Cleanliness Inspection for Visual Contaminants on Cleaned Steel Surface Using Comparator to Measuring Profile Height on Blast-Cleaned Steel Surfaces
Using Replicate Tape to Measure Profile Height of Blasted Steel
Measuring Coating Wet Film Thickness
Measuring Coating Dry Film Thickness on Steel Using Magnetic
Gauges
Measuring Coating Dry Film Thickness Using Tooke (PIG) Gauge
Ultrasonic Gauges for Thickness Measurements
Using Mirror to Inspect Hard-to-Reach Areas
Measuring Coating Adhesion
Measuring Moisture in Concrete or Wood
Detecting Holidays in Coatings
Measuring Temperatures on Substrates/Materials
Using remote-sensing thermometer to measure temperature on coated steel
http://www.sspc.org/site/C2course/C_2/equipdem/equipdem.html (1 of 6) [8/25/04 2:27:11 AM]
Inspection Equipment Demonstrations
Using Psychrometer to Determine Dew Point
Removing sling psychrometer from case to measure dew point (ASTM E 337)
Slinging psychrometer to equilibrate thermometer
temperatures
Psychrometric tables for converting thermometer
readings to dew point (cover)
Psychrometric tables for converting thermometer
readings to dew point (interior)
Battery operated psychrometer
Detecting Residual Oil on Cleaned Surfaces
Residual water beads from water-break test on oilcontaminated concrete surface (Photo courtesy Prosoco, Inc.)
Measuring Pressure of Air/Abrasive Flow at Nozzle
Hypodermic needle gauge to be inserted into whip hose just below nozzle
Inserting hypodermic needle into whip hose in the
direction of flow
Using SSPC-VIS 1-89 Standards to Detect Level of Cleanliness
Comparing cleanliness of abrasive-blasted steel surface to SSPC-VIS 1-89 standard photographs
Inspection for Visual Contaminants on Cleaned Steel Surface
http://www.sspc.org/site/C2course/C_2/equipdem/equipdem.html (2 of 6) [8/25/04 2:27:11 AM]
Inspection Equipment Demonstrations
Using pocket-size, illuminated microscope to detect
visual contaminants on blast cleaned steel
Using Comparator to Measuring Profile Height on Blast-Cleaned Steel
Surfaces Comparator used to measure surface profile of blast cleaned steel (ASTM D 4417, Method A)
Determining profile height of blasted steel using
comparator
Using Replicate Tape to Measure Profile Height of Blasted Steel
Replicate tape test equipment for measuring profile height (ASTM D 4417, Method C): tape in dispenser, plastic swizzle stick, and spring micrometer Pressing replicate tape into steel profile
Measuring profile of replicated tape in spring
micrometer
Measuring Coating Wet Film Thickness
Wet film thickness gauge with four flat, notched faces, each with a different range (ASTM D 4414, Procedure A) Pressing wet film thickness gauge into wet paint
Visually checking notches for wet paint to
determine wet film thickness
Using circular notched "hotcake" gauge to measure
wet film thickness (ASTM D 4414, Procedure B)
Measuring Coating Dry Film Thickness on Steel Using Magnetic Gauges
http://www.sspc.org/site/C2course/C_2/equipdem/equipdem.html (3 of 6) [8/25/04 2:27:11 AM]
Inspection Equipment Demonstrations
Banana type magnetic dry film thickness gauge
showing magnet on tip (SSPC-PA 2, Type 1A; ASTM D 1186, Method A) Banana gauge measuring dry film thickness of coating
Measuring coating dry film thickness with constant
pressure (magnetic flux) probe (SSPC-PA 2 Type 2; ASTM D 1186, Method B)
Measuring coating dry film thickness using
magnetic gauge with remote probe
Standard thickness plates for calibrating magnetic
dry film thickness gauges
Using standard thickness plates to calibrate a dry
film thickness gauge
Standard-thickness plastic shims for calibrating dry
film thickness gauges
Calibrating dry film thickness gauge using blue
plastic shim
Measuring Coating Dry Film Thickness Using Tooke (PIG) Gauge
Tooke (PIG) destructive gauge (showing cutting blade) for measuring dry film thickness (ASTM D 4138) Coating cut through to substrate at marked black line by Tooke gauge blade
Looking through illuminated and calibrated
microscope of Tooke gauge to measure coating dry film thickness
Ultrasonic Gauges for Thickness Measurements
http://www.sspc.org/site/C2course/C_2/equipdem/equipdem.html (4 of 6) [8/25/04 2:27:11 AM]
Inspection Equipment Demonstrations
Ultrasonic equipment for measuring coating dry
film thickness
Applying couplant to coated concrete specimen
prior to measuring dry film thickness
Ultrasonically measuring dry film thickness of
coating on concrete specimen
Ultrasonic gauge for measuring steel thickness
Applying couplant to steel surface prior to
measuring steel thickness
Measuring thickness of steel with ultrasonic gauge
Using Mirror to Inspect Hard-to-Reach Areas
Using mirror to inspect coating under flange
Measuring Coating Adhesion
Adhesion test video This is a 9.5 minute Quicktime format video
demonstrating the use of pull off adhesion (2.8MB) testers.(Quicktime Plugin required to play) Kit for use with ASTM D 3359, Method B
Cutting lattice for ASTM D 3359, Method B
Removing cellophane tape from lattice
Evaluating adhesion after conducting ASTM D 3359,
Method B
http://www.sspc.org/site/C2course/C_2/equipdem/equipdem.html (5 of 6) [8/25/04 2:27:11 AM]
Inspection Equipment Demonstrations
Fixed alignment adhesion tester showing where
dolly is joined after its bonding to coated surface (ASTM D 4541, Annex A1)
Kit for self-aligning, pneumatic adhesion tester
(ASTM D 4541, Annex 2A) (Note larger dollies for coatings on concrete)
Self-aligning, pneumatic adhesion testing
equipment ready for use
Measuring Moisture in Concrete or Wood
Conductivity meter used for measuring moisture in concrete or wood
Measuring moisture near surface of wood using
moisture meter with short probes
Long, remote probes with meter used for
measuring moisture deep inside wood or concrete
Detecting Holidays in Coatings
Detecting holidays in thin coating films (less than 20 mils) using low voltage (30 to 70 volts) wetsponge holiday detector (ASTM D 5162, NACE RP0188) Another high-voltage (over 70 volts) holiday detector in use for detecting holidays in coatings greater than 20 mils.
http://www.sspc.org/site/C2course/C_2/equipdem/equipdem.html (6 of 6) [8/25/04 2:27:11 AM]