XYPEX
eM rere Ree een)
METHOD STATEMENT
Xypex Concentrate Honeycomb/Structural Repairs
* Route out faulty concrete to sound concrete.
* Remove all loose materials and saturate area with water.
Allow time for concrete to absorb water, then remove all free
standing water.
+ Apply a slurry coat of Xypex Concentrate to cavity area at a
coverage rate of 0.8 kg/m?,
* Whilst slurry coat is still tacky, fill cavity for surface with
Xypex concentrate dry-pac/patch n plug.
* Allow patch to set, then apply a slurry coat of Xypex
concentrate over the repaired area at a coverage rate of 0.8
kg/m?.
* Cure by fog spraying water for 2 days or apply Xypex Gamma
Cure immediately after Xypex repair has set.
ease rae: The meth statment above shouldbe readin conjunction wth Specfeton and Appleton manuel produced by Xypex
(Chemical Corporation. ky consistency nth the mona, then the Mandal take roceenee,
XYPEX — UK DISTRIBUTORS
ir ‘SMR PROJECTS LIMITED
rt XypexHouse, St.Thomas Street, Deddngton Oxon OXI5 0SY
Cony Rain «7808 VAT No 812079653 {0844 800 2705 f 0844 800 2706
‘Nohara raters op Chon Crprton €info@smoypexco.uk w. smoypaxco uk