Air Dryer

The Air Dryer failed to work as usual and continually leaking air.
The pressure seal of the piston get damage
Bring new one and repair kit

FD140 Transfer case


-

Malfunction on manual transfer case on carrier. While prepare for rig


move from Neem SN-1 to Neem 21 . and after move the carrier from rig
matting we transfer the shaft from prime mover to draw-works on
18.Oct.The next day we tried to return the motion to prime mover the
transfer case refused to response.

FD140 Transfer case


There was misalignment in transfer case on the draw-works side, which
makes the disengage process unable. Also there was kind of
contamination on system. (the sliding sleeve wasnt free).
- Observe transmission oil and gear oil level before any process.
Obtain the preventive maintenance on periodical bases.

Hydraulic Control Switches.

While tripping in with DBP, after resuming operation the Hyd Control Switches
started leaking with high pressure.

Also the internal seal damaged.


We changed the switch by another one but still some valves not working.

Now we cont. in repairing by changing valves and trying.


-Hydraulic Control Switches.

The most probable reason is long using and the seals are not quite good in quality.
And the Maximum Relieve valve not working.
Send new hydraulic distribution switch case ASAP because this is
not first time to be failure. with enough quality seals (see the
photos of seals below).
- Check whole hydraulic hoses and system.
Check the Max. Relieve valve.
-

The Gen Set No.1 (SN: 2013249586) started on 21.Dec (due to fault in the
Gen Set No.2), On 22.Dec stopped due to high coolant temperature error.
VOLVO TAD1343GE Radiator
the dirt in the radiator cause the engine temperature to rise and reach 90c

Send the radiator to heglig for clean up.

On 21.Dec @8:00am in the morning the Gen Set No.2 (SN:


20132442470) stopped due to error 4151(change to the other
generator Gen Set No.1), On 22.Dec the Gen Set No.1 Stopped due
high coolant temperature, decided to operate Gen Set No.2 check all
sensor readings Ok, found OMC Power Trim relay make unusual
sound when hold the relay strong the error was removed the engines
worked for 15mins then stopped, found error Low Frequency. On
23.Dec took the same relay from the other generator and tested for
6hrs appear good sign and no errors in the generator screen(the test
without load).
VOLVO TAD1343GE SN: 20132442470
OMC Power Trim Relay (V23134-A56-X397, PN: 20374662)
OMC Power Trim Relay misreading cause generator shutdown.

Send the relay ASAP.