You are on page 1of 39

FAST VP for EMC Symmetrix VMAX

Theory a nd Best Pra ctices


for Pla nning a nd Performa nce

Technica l Notes
P/ N 300- 012- 014
REV A04
June 2012

This technical notes d ocu m ent contains inform ation on these top ics:

Execu tive su m m ary ................................................................................... 2


Introd u ction and overview ....................................................................... 2
Fu lly Au tom ated Storage Tiering ............................................................ 3
FAST and FAST VP com p arison .............................................................. 5
Theory of op eration ................................................................................... 6
Perform ance consid erations ................................................................... 11
Prod u ct and featu re interop erability ..................................................... 14
Planning and d esign consid erations ..................................................... 17
Su m m ary and conclu sion ....................................................................... 34
Ap p end ix: Best p ractices qu ick reference ............................................. 37

Executive summary

Executive summary

EMC Sym m etrix VMAX Fam ily w ith Enginu ity incorp orates a
scalable fabric-interconnect d esign that allow s a storage array to
seam lessly grow from an entry-level configu ration to a 4 PB system .
Sym m etrix VMAX Series arrays p rovid e p red ictable, self-op tim izing
p erform ance and enables organ izations to scale ou t on d em and in
p rivate clou d environm ents.
VMAX Series arrays au tom ate storage op erations to exceed bu siness
requ irem ents in virtu alized environm ents, w ith m anagem ent tools that
integrate w ith virtu alized servers and red u ce ad m inistra tion tim e in
p rivate clou d infrastru ctu res. Cu stom ers are able to achieve alw ays -on
availability w ith m axim u m secu rity, fu lly nond isru p tive op erations , and
m u lti-site m igration, recovery, and restart to p revent ap p lication
d ow ntim e.
Inform ation infrastru ctu re m u st continu ou sly ad ap t to changing
bu siness requ irem ents. EMC Sym m etrix Fully Au tom ated Storage
Tiering for Virtu al Pools (FAST VP) au tom ates tiered storage strategies,
in Virtu al Provisioning environm ents, by easily m oving w orkload s
betw een Sym m etrix tiers as p erform ance characteristics change over
tim e. FAST VP p erform s d ata m ovem ents, im p roving p erform ance , and
red u cing costs, all w hile m aintaining vital service levels.

Introduction a nd overview
EMC Sym m etrix VMAX FAST VP for Virtu al Provisioning environm ents
au tom ates the id entification of d ata volu m es for the p u rp oses of
relocating ap p lication d ata across d ifferent p erform ance/ cap acity tiers
w ithin an array. FAST VP p roactively m onitors w orkload s at both the
LUN and su b-LUN level in ord er to id entify bu sy d ata that w ou ld
benefit from being m oved to higher -p erform ing d rives. FAST VP also
id entifies less-bu sy d ata that cou ld be m oved to higher -cap acity d rives
w ithou t existing p erform ance being affected . This p rom otion/ d em otion
activity is based on p olicies that associate a storage grou p to m u ltip le
d rive technologies, or RAID p rotection schem es, by w ay of thin storage
p ools, as w ell as the p erform ance requ irem ents of the ap p lication
contained w ithin the storage grou p . Data m ovem ent execu ted d u ring
this activity is p erform ed nond isru p tively, w ithou t affecting bu siness
continu ity and d ata availability.

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Fully Automated Storage Tiering


Audience
This technical notes d ocu m ent is intend ed for anyone w ho need s to
u nd erstand FAST VP theory, best p ractices, and associated
recom m end ations as necessary to achieve the best p erform ance for FAST
VP configu rations. This d ocu m ent is sp ecifically targeted to EMC
cu stom ers, sales, and field technical staff w ho are either ru nning FAST
VP or are consid ering FAST VP for fu tu re im p lem entation.
Significant p ortions of this d ocu m ent assu m e a base know led ge
regard ing the im p lem entation and m anagem ent of FAST VP. For
inform ation regard ing the im p lem entation and m anagem ent of FAST VP
in Virtu al Provisioning environm ents, refer to the Implementing Fully
A utomated Storage Tiering for V irtual Pools (FA ST V P) for EM C Symmetrix
V M A X Series A rrays Technical N ote (P/ N 300-012-015).

Fully Automa ted Stora ge Tiering


Fu lly Au tom ated Storage Tiering (FAST) au tom ates the id entification of
d ata volu m es for the p u rp oses of relocating ap p lication d ata across
d ifferent p erform ance/ cap acity tiers w ithin an array , or to an external
array u sing Fed erated Tiered Storage (FTS).
The p rim ary benefits of FAST inclu d e:

Elim ination of m anu ally tiering ap p lications w hen p erform ance


objectives change over tim e.

Au tom ating the p rocess of id entifying d ata that can benefit from
Enterp rise Flash Drives or that can be kep t on higher -cap acity,
less-exp ensive SATA d rives w ithou t im p acting p erform ance.

Im p roving ap p lication p erform ance at the sam e cost, or


p rovid ing the sam e ap p lication p erform ance at low er cost. Cost
is d efined as acqu isition (both hard w are and softw are),
sp ace/ energy, and m anagem ent exp ense.

Op tim izing and p rioritizing bu siness ap p lications, allow ing


cu stom ers to d ynam ically allocate resou rces w ithin a single
array.

Delivering greater flexibility in m eeting d ifferent


p rice/ p erform ance ratios throu ghou t the lifecycle of the
inform ation stored .

Du e to ad vances in d rive technology, and the need for storage


consolid ation, the nu m ber of d rive typ es su p p orted by Sym m etrix arrays
has grow n significantly. These d rives sp an a range of storage service
sp ecializations and cost characteristics that d iffer greatly.
FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Fully Automated Storage Tiering

Several d ifferences exist betw een the fou r d rive technologies su p p orted
by the Sym m etrix VMAX Series arrays: Enterprise Flash Drive (EFD), Fibre
Channel (FC), Serial Attach SCSI (SAS), and SATA. The p rim ary
d ifferences are:

Resp onse tim e

Cost p er u nit of storage cap acity

Cost p er u nit of storage requ est p rocessing

At one extrem e are EFDs, w hich have a very low resp onse
tim e, bu t w ith a high cost p er u nit of storage cap acity

At the other extrem e are SATA d rives, w hich have a low


cost p er u nit of storage cap acity, bu t high resp onse tim es
and high cost p er u nit of storage requ est p rocessing

Betw een these tw o extrem es lie Fibre Channel and SAS


d rives

Based on the natu re of the d ifferences that exist betw een these fou r d rive
typ es, the follow ing observations can be m ad e regard ing the m ost su ited
w orkload typ e for each d rive.

Enterp rise Flash Drives: EFDs are m ore su ited for


w orkload s that have a high back-end rand om read storage
requ est d ensity. Su ch w orkload s take ad vantage of both
the low resp onse tim e p rovid ed by the d rive, and the low
cost p er u nit of storage requ est p rocessing w ithou t
requ iring a log of storage cap acity.

SATA d rives: SATA d rives are su ited tow ard w orkload s


that have a low back-end storage requ est d ensity.

Fibre Channel/ SAS d rives: Fibre Channel and SAS d rives


are the best d rive typ e for w ork load s w ith a back-end
storage requ est d ensity that is not consistently high or low .

This d isp arity in su itable w orkload s p resents both an op p ortu nity and a
challenge for storage ad m inistrators.
To the d egree it can be arranged for storage w orkload s to be served by
the best su ited d rive technology, the op p ortu nity exists to im p rove
ap p lication p erform ance, red u ce hard w are acqu isition exp enses, and
red u ce op erating exp enses (inclu d ing energy costs and sp ace
consu m p tion).
The challenge, how ever, lies in how to realize these benefits w ithou t
introd u cing ad d itional ad m inistrative overhead and com p lexity.
The ap p roach taken w ith FAST is to au tom ate the p rocess of id entifying
w hich regions of storage shou ld resid e on a given d rive technology, and
4

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

FAST and FAST VP comparison


to au tom atically and nond isru p tively m ove storage betw een tiers to
op tim ize storage resou rce u sage accord ingly. This also need s to be d one
w hile taking into accou nt op tional constraints on tier cap acity u sage that
m ay be im p osed on sp ecific grou p s of storage d evices.

FAST a nd FAST VP compa rison


EMC Sym m etrix VMAX FAST and FAST VP au tom ate the id entification
of d ata volu m es for the p u rp oses of relocating ap p lication d ata across
d ifferent p erform ance/ cap acity tiers w ithin an array, or to an external
array u sing Fed erated Tiered Storage (FTS). While the ad m inistration
p roced u res u sed w ith FAST VP are very sim ilar to those available w ith
FAST, there is a m ajor d ifference: The storage p ools u sed by FAST VP are
thin storage p ools.
FAST op erates on non-thin, or d isk-grou p -p rovisioned , Sym m etrix
volu m es. Data m ovem ents execu ted betw een tiers are p erform ed at the
fu ll-volu m e level. FAST VP op erates on Virtu al Provisioning thin
d evices. As su ch, d ata m ovem ents execu ted can be p erform ed at the su bLUN level, and a single thin d evice m ay have extents allocated across
m u ltip le thin p ools w ithin the array, or on an external array u sing FTS.
N ote: For m ore inform ation on Virtual Provisioning, refer to the Best Practices
for Fast, Simple Capacity A llocation with EM C Symmetrix V irtual Provisioning
Technical N ote available at http :/ / pow erlink.em c.com .
N ote: For m ore inform ation on Fed erated Tiered Storage, refer to the Design
and Implementation Best Practices for EM C Symmetrix Federated Tiered Storage
(FTS) technical note available at http:/ / pow erlink.em c.com .

Becau se FAST and FAST VP su p p ort d ifferent d evice typ es, non-thin and
thin, resp ectively, they both can op erate sim u ltaneou sly w ithin a single
array. Asid e from som e shared configu ration p aram eters, the
m anagem ent and op eration of each can be consid ered sep arately.
N ote: For m ore inform ation on FAST refer to the Implementing Fully
A utomated Storage Tiering (FA ST) for EM C Symmetrix V M A X Series A rrays
technical note available at http :/ / pow erlink.em c.com .

The goal of FAST and FAST VP is to op tim ize the p erform ance and costefficiency of configu rations containing m ixed d rive technologies. While
FAST m onitors and m oves storage in u nits of entire logical d evices,
FAST VP m onitors d ata access w ith m u ch finer granu larity. This allow s
FAST VP to d eterm ine the m ost ap p rop riate tier (based on op tim izing
p erform ance and cost efficiency) for each 120 track region of storage. In
FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Theory of operation

this w ay, the ability of FAST VP to m onitor and m ove d ata w ith m u ch
finer granu larity greatly enhances the valu e p rop osition of au tom ated
tiering.
FAST VP bu ild s u p on and extend s the existing cap abilities of Virtu al
Provisioning and FAST to p rovid e the u ser w ith enhanced Sym m etrix
tiering op tions. The Virtu al Provisioning u nd erp innings of FAST VP
allow FAST VP to com bine the core benefits of Virtu al Provisioning
(w id e strip ing and thin p rovisioning) w ith the benefits of au tom ated
tiering.
FAST VP m ore closely aligns storage access w orkload s w ith the bestsu ited d rive technology than is p ossible if all regions of a given d ev ice
m u st be m ap p ed to the sam e tier. At any given tim e, the hot regions of a
thin d evice m anaged by FAST VP m ay be m ap p ed to an EFD tier, and
the w arm p arts m ay be m ap p ed to an FC tier, w hile the cold p arts m ay
be m ap p ed to a SATA tier. By m ore effectively exp loiting d rive
technology sp ecializations, FAST VP d elivers better p erform ance and
greater cost efficiency that FAST.
FAST VP also better ad ap ts to shifting w orkload locality of reference,
changes in tier-allocation lim its, or storage-grou p p riority. This is d u e to
the fact that the workload m ay be ad ju sted by m oving less d ata. This
fu rther contribu tes to m aking FAST VP m ore effective at exp loiting d rive
sp ecializations and also enhances som e of the op erational ad vantages of
FAST. This inclu d es the ability to nond isru p tively ad ju st the qu ality of
storage service (resp onse tim e and throu ghp u t) p rovid ed to a storage
grou p .

Theory of opera tion


There are tw o com p onents of FAST VP: Sym m etrix Enginu ity and the
FAST controller. Sym m etrix Enginu ity storage is the op erating
environm ent that controls com p onents w ithin the array. The FAST
controller is a service that ru ns on the service p rocessor.

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Theory of operation

Figure 1. FAST VP components


When FAST VP is active, both com p onents p articip ate in the execu tion of
tw o algorithm s (the intelligent tiering algorithm and the allocation
com p liance algorithm ) to d eterm ine ap p rop riate d ata p lacem ent.
The intelligent tiering algorithm u ses p erform ance d ata collected by
Enginu ity, as w ell as su p p orting calcu lations p erform ed by the FAST
controller, to issu e d ata m ovem ent requ ests to the Virtu al LUN (VLUN )
VP d ata m ovem ent engine.
The allocation com p liance algorithm enforces the u p p er lim its of storage
cap acity that can be u sed in each tier by a given storage grou p by also
issu ing d ata m ovem ent requ ests to the VLUN VP d ata m ovem ent
engine.
Perform ance tim e w ind ow s can be d efined to sp ecify w hen the FAST VP
controller shou ld collect p erform ance d ata, u p on w hich analysis is
p erform ed to d eterm ine the ap p rop riate tier for d evices. By d efau lt, this
FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Theory of operation

occu rs 24 hou rs a d ay.


Defined d ata m ovem ent w ind ow s d eterm ine w hen to execu te the d ata
m ovem ents necessary to m ove d ata betw een tiers.
Data m ovem ents p erform ed by Enginu ity are achieved by m oving
allocated extents betw een tiers. The size of d ata m ovem ent can be as
sm all as 12 tracks, rep resenting a single allocated thin d evice extent, bu t
m ore typ ically it is a u nit know n as an extent grou p , w hich is 120 tracks.
The follow ing sections fu rther d escribe each of these algorithm s.

Intelligent tiering a lgorithm


The goal of the intelligent tiering algorithm is to u se the p erform ance
m etrics collected at the su b-LUN level to d eterm ine w hich tier each
extent grou p shou ld resid e in and to su bm it the need ed d ata m ovem ents
to the VLUN VP d ata m ovem ent engine. The d eterm ination of w hich
extent grou p s need to be m oved is p erform ed by a task that ru ns w ithin
the Sym m etrix array.
The intelligent tiering algorithm is stru ctu red into tw o com p onents : a
m ain com p onent that execu tes w ithin Enginu ity and a second ary,
su p p orting com p onent that execu tes w ithin the FAST controller on the
service p rocessor.
The m ain com p onent assesses w hether extent grou p s need to be m oved
in ord er to op tim ize the u se of the FAST VP storage tiers. If so, the
requ ired d ata m ovem ent requ ests are issu ed to the VLUN VP d ata
m ovem ent engine.
When d eterm ining the ap p rop riate tier for each extent grou p , the m ain
com p onent m akes u se of both the FAST VP m etrics, p reviou sly
d iscu ssed , and su p p orting calcu lations p erform ed by the second ary
com p onent on the service p rocessor.
The intelligent tiering algorithm ru ns continu ou sly d u ring op en d ata
m ovem ent w ind ow s w hen FAST is enabled and the FAST VP op erating
m od e is Au tom atic. As su ch, p erform ance-related d ata m ovem ents can
occu r continu ou sly d u ring an op en d ata m ovem ent w ind ow .

Allocation complia nce a lgorithm


The goal of the allocation com p liance algorithm is to d etect and correct
situ ations w here the allocated cap acity for a p articu lar storage grou p
w ithin a thin storage tier exceed s the m axim u m cap acity allow ed by the
associated FAST p olicy.

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Theory of operation
A storage grou p is consid ered to be in com p liance w ith its associated
FAST p olicy w hen the configu red cap acity of the thin d evices in the
storage grou p is located on tiers d efined in the p olicy , and w hen the
u sage of each tier is w ithin the u p p er lim its of the tier u sage lim its
sp ecified in the p olicy.
Com p liance violations m ay occu r for m u ltip le reasons, inclu d ing:

N ew extent allocations p erform ed for thin d evices


m anaged by FAST VP

Changes m ad e to the u p p er u sage lim its for a VP tier in a


FAST p olicy

Ad d ing thin d evices to a storage grou p that are them selves


ou t of com p liance

Manu al VLUN VP m igrations of thin d evices

The com p liance algorithm attem p ts to m inim ize the am ou nt of


m ovem ents p erform ed to correct com p liance that m ay, in tu rn, gene rate
m ovem ents p erform ed by the intelligent tiering algorithm . This is d one
by coord inating the m ovem ent requ ests w ith the analysis p erform ed by
the intelligent tiering algorithm to d eterm ine the m ost ap p rop riate
extents to be m oved , and the m ost ap p rop ria te tier to be m oved to, w hen
correcting com p liance violations.
When FAST is enabled and the FAST VP op erating m od e is Au tom atic,
the com p liance algorithm ru n s every 10 m inu tes d u ring op en d ata
m ovem ent w ind ow s.

Da ta movement
Data m ovem ents execu ted by FAST VP are p erform ed by the VLUN VP
d ata m ovem ent engine, and involve m oving thin d evice extents betw een
thin p ools w ithin the array. Extents are m oved by w ay of a m ove
p rocess only; extents are not sw ap p ed betw een p ools.
The m ovem ent of extents, or extent grou p s, d oes not change the thin
d evice bind ing inform ation. The thin d evice still rem ain s bou nd to the
p ool it w as originally bou nd to. N ew allocations for the thin d evice, as
the resu lt of host w rites, w ill continu e to com e from the bou nd p ool,
u nless VP allocation by FAST VP is enabled .
To com p lete a m ove, the follow ing m u st hold tru e:

The FAST VP op erating m od e m u st be Au tom atic.

The VP d ata m ovem ent w ind ow m u st be op en.

The thin d evice affected m u st not be p inned .

There m u st be su fficient u nallocated sp ace in the thin

FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Theory of operation

p ools inclu d ed in the d estination tier to accom m od ate the


d ata being m oved .

The d estination tier m u st contain at least one thin p ool that


has not exceed ed the p ool reserved cap acity (PRC).

N ote: If the selected d estination tier contains only pools that have reached the
PRC lim it, then an alternate tier m ay be consid ered by the movem ent task.

Other m ovem ent consid erations inclu d e:

Only extents that are allocated w ill be m oved .

N o back-end configu ration changes are p erform ed d u ring


a FAST VP d ata m ovem ent, and , as su ch, no configu ration
locks are held d u ring the p rocess.

As sw ap s are not p erform ed , there is no requ irem ent for


any sw ap sp ace, su ch as DRVs, to facilitate d ata
m ovem ent.

Data m ovem ent tim e w ind ow s are u sed to sp ecify d ate and tim e ranges
w hen d ata m ovem ents are allow ed , or not allow ed , to be p erform ed .
FAST VP d ata m ovem ents ru n as low -p riority tasks on the Sym m etrix
back end . Data m ovem ent w ind ow s can be p lanned so as to m inim ize
im p act on the p erform ance of other m ore critical w orkload s.
A d efau lt d ata m ovem ent tim e w ind ow exclu d es all p erform ance d ata
sam p les 24 hou rs a d ay, 7 d ays a w eek, 365 d ays a year. There are tw o
typ es of d ata m ovem ent that can occu r u nd er FAST VP : Those generated
by the intelligent tiering algorithm and those generated by the allocation
com p liance algorithm . Both typ es of d ata m ovem ent only occu r d u ring
u ser-d efined d ata m ovem ent w ind ow s.
Related m ovem ents of the intelligent tiering algorithm are requ ested and
execu ted by Enginu ity. These d ata m ovem ents are governed by the
w orkload on each extent grou p , bu t m ay only be execu ted w ithin the
constraints of the associated FAST p olicy. Th erefore, a p erform ance
m ovem ent cannot cau se a storage grou p to becom e non -com p liant w ith
its FAST p olicy.
Allocation com p liance related m ovem ents are generated by the FAST
controller and execu ted by Enginu ity. These m ovem ents bring the
cap acity of the storage grou p back w ithin the bou nd aries sp ecified by the
associated p olicy. Perform ance inform ation from the intelligent tiering
algorithm is u sed to d eterm ine m ore ap p rop riate su b -extents to m ove
w hen restoring com p liance.
When a com p liance violation exists, the algorithm generate s a d ata
m ovem ent requ est to retu rn the allocations w ithin the requ ired lim its.
10

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Performance considerations
This requ est exp licitly ind icates w hich thin d evice extents shou ld be
m oved , and the sp ecific thin p ools they shou ld be m oved to.

Performa nce considera tions


The Enginu ity op erating environm ent collects and m aintains
p erform ance d ata that is u sed by FAST VP. The FAST controller analyzes
the p erform ance d ata to d eterm ine the best location to p lace the thin
d evice d ata on the d efined VP tiers w ithin the Sym m etrix array.

Performa nce metrics


When collecting p erform ance d ata at the LUN and su b-LUN level for u se
by FAST VP, Enginu ity only collects statistics related to Sym m etrix back end activity that is the resu lt of host I/ O. The m etrics collected are:

Read m iss

Write

Prefetch (sequ ential read )

The read m iss m etric accou nts for each DA read op eration that is
p erform ed . Read s to areas of a thin d evice that have not had sp ace
allocated in a thin p ool are not cou nted . Also, read hits, w hich are
serviced from cache, are not consid ered .
Write op erations are cou nted in term s of the nu m ber of d istinct DA
op erations that are p erform ed . The m etric accou nts for w hen a w rite is
d estaged w rite hits, to cache, are not consid ered .
Writes related to sp ecific RAID p rotection schem es are also not cou nted .
In the case of RAID 1 p rotected d ev ices, the w rite I/ O is only cou nted for
one of the m irrors. In the case of RAID 5 and RAID 6 p rotected d evices,
p arity read s and w rites are not cou nted .
Prefetch op erations are accou nted for in term s of the nu m ber of d istinct
DA op erations p erform ed to p refetch d ata sp anning a FAST VP extent.
This m etric consid ers each DA read op eration p erform ed as a front-end
p refetch op eration.
Workload related to internal cop y op erations, su ch as d rive rebu ild s,
clone op erations, VLUN m igrations, or even FAST VP d ata m o vem ents,
is not inclu d ed in the FAST VP m etrics.
These FAST VP p erform ance m etrics p rovid e a m easu re of activity that
assigns greater w eight to m ore recent I/ O requ ests, bu t are also
influ enced by less recent activity. By d efau lt, based on a w orkload
analysis p eriod of 24 hou rs, an I/ O that has ju st been received is
w eighted tw o tim es m ore heavily than an I/ O received 24 hou rs
FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

11

Performance considerations

p reviou sly.
N ote: Perform ance m etrics are only collected d uring user -d efined
perform ance tim e w ind ow s. The tim es d uring w hich m etrics are not being
collected d oes not contribute to red ucing the w eight assigned to those m etrics
alread y collected .

The m etrics collected at the su b-LUN level for thin d evices u nd er FAST
VP control contain m easu rem ents to allow FAST VP to m ake sep arat e
d ata m ovem ent requ ests for each 120 tracks u nit of storage that m ake u p
the thin d evice. This u nit of storage consists of 10 contigu ou s thin d evice
extents and is know n as an extent grou p .
In ord er to m aintain the su b-LUN -level m etrics collected by Enginu ity,
the Sym m etrix array allocates one cache slot for each thin d evice that is
u nd er FAST VP control.
When m anaging m etad evices, cache slots are allocated for both the
m etahead and for each of the m etam em bers.
N ote: Each cache slot on a Sym m etrix VMAX Series array is one track in size.

FAST VP tuning
FAST VP p rovid es a nu m ber of p aram eters that can be u sed to tu ne the
p erform ance of FAST VP and to control the aggressiveness of the d ata
m ovem ents. These p aram eters can be u sed to nond isru p tively ad ju st the
am ou nt of tier storage that a given storage grou p is allow ed to u se, or to
ad ju st the m anner in w hich storage grou p s u sing the sam e tier com p ete
w ith each other for sp ace.
FAST VP reloca tion ra te
The FAST VP relocation rate (FRR) is a qu ality of service (QoS) setting
for FAST VP and affects the aggressiveness of d ata m ovem ent requ ests
generated by FAST VP. This aggressiveness is m easu red as the am ou nt
of d ata that is requ ested to be m oved at any given tim e, and the p riority
given to m oving the d ata betw een p ools.
N ote: The rate at w hich d ata is m oved betw een pools can also be controlled
by m eans of the Sym m etrix Quality of Service VLUN setting.

Pool reserved ca pa city


The Pool reserved cap acity (PRC) reserves a p ercentage of each p ool
inclu d ed in a VP tier for non -FAST VP activities. The p u rp ose of this is to
ensu re that FAST VP d ata m ovem ents d o not fill a thin p ool, and
12

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Performance considerations
su bsequ ently cau se a new extent allocation (a resu lt of a host w rite) to
fail.
The PRC can be set both system -w id e and for each ind ivid u al p ool. By
d efau lt, the system -w id e setting is ap p lied to all thin p ools that have
been inclu d ed in VP tier d efinitions. H ow ever, this can be overrid d en for
each ind ivid u al p ool by u sing the p ool-level setting.
When the p ercentage of u nallocated sp ace in a thin p ool is equ al to the
PRC, FAST VP no longer p erform s d ata m ovem ents into that p ool.
H ow ever, d ata m ovem ents m ay continu e to occu r ou t of the p ool to
other p ools. When the p ercentage of u nallocated sp ace becom es greater
than the PRC, FAST VP can begin p erform ing d ata m ovem ents into that
p ool again.
FAST VP time windows
FAST VP u tilizes tim e w ind ow s to d efine certain behaviors regard ing
p erform ance d ata collection and d ata m ovem ent. There are tw o p os sible
w ind ow typ es:

Perform ance tim e w ind ow

Data m ovem ent tim e w ind ow

The p erform ance tim e w ind ow s are u sed to sp ecify w hen p erform ance
m etrics shou ld be collected by Enginu ity.
The d ata m ovem ent tim e w ind ow s d efine w hen to p erform the d ata
relocations necessary to m ove d ata betw een tiers. Sep arate d ata
m ovem ent w ind ow s can be d efined for fu ll LUN m ovem ent, p erform ed
by FAST and Op tim izer, and su b-LUN d ata m ovem ent p erform ed by
FAST VP.
Both p erform ance tim e w ind ow s and d ata m ovem ent w ind ow s m ay be
d efined as inclu sion or exclu sion w ind ow s. An inclu sion tim e w ind ow
ind icates that the action shou ld be p erform ed d u ring the d efined tim e
w ind ow . An exclu sion tim e w ind ow ind icates that the action shou ld be
p erform ed ou tsid e the d efined tim e w ind ow .
Performa nce time window
The p erform ance tim e w ind ow s are u sed to id entify the bu siness cycle
for the Sym m etrix array. They sp ecify d ate and tim e ranges (p ast or
fu tu re) w hen p erform ance sam p les shou ld be collected , or not collected ,
for the p u rp oses of FAST VP p erform ance analysis. The intent of
d efining p erform ance tim e w ind ow s is to d istingu ish p eriod s of tim e
w hen the Sym m etrix array is id le from p eriod s w hen it is active, and to
only inclu d e p erform ance d ata collected d u ring the active p eriod s.
By d efau lt, p erform ance m etrics are collected 24 hou rs a d ay, 7 d ays a
FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

13

Product and feature interoperability

w eek, 365 d ays a year.


Da ta movement time window
Data m ovem ent tim e w ind ow s are u sed to sp ecify d ate and tim e ranges
w hen d ata m ovem ents are allow ed , or not allow ed , to be p erform ed .
FAST VP d ata m ovem ents ru n as low -p riority tasks on the Sym m etrix
back end . By d efau lt, d ata m ovem ent is p revented 24 hou rs a d ay, 7 d ays
a w eek, 365 d ays a year.
Stora ge group priority
When a storage grou p is associated w ith a FAST p olicy, a p riority valu e
m u st be assigned to the storage grou p . This p riority valu e can be
betw een 1 and 3, w ith 1 being the highest p riority . The d efau lt is 2.
When m u ltip le storage grou p s share the sam e p olicy, the p riority valu e
is u sed w hen the d ata contained in the storage grou p s is com p eting for
the sam e resou rces in one of the associated tiers. Storage grou p s w ith a
higher p riority are given p reference w hen d ecid ing w hich d ata need s to
be m oved to another tier.

Product a nd fea ture interopera bility


FAST VP is fu lly interop erable w ith all Sym m etrix rep lication

technologies: EMC SRDF , EMC Tim eFind er / Clone, Tim eFind er/ Snap ,
and Op en Rep licator. Any active rep lication on a Sym m etrix d evice
rem ains intact w hile d ata from that d evice is being m oved . Sim ilarly, all
increm ental relationship s are m aintained for the m oved or sw ap p ed
d evices. FAST VP also op erates alongsid e Sym m etrix featu res, su ch as
Sym m etrix Op tim izer, Dynam ic Cache Partitioning, and Au top rovisioning Grou p s.
SRDF
Thin SRDF d evices, R1 or R2, can be associated w ith a FAST p olicy.
Extents of SRDF d evices can be m oved betw een tiers w hile the d evices
are being actively rep licated , in either synchronou s or asynchronou s
m od e.
TimeFinder/ Clone
Both the sou rce and target d evices of a Tim eFind er/ Clone session can be
m anaged by FAST VP. H ow ever, the sou rce and target are m anaged
ind ep end ently, and , as su ch, m ay end u p w ith d ifferent extent
allocations across tiers.

14

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Product and feature interoperability


TimeFinder/ Sna p
The sou rce d evice in a Tim eFind er/ Snap session can be m anaged by
FAST VP. H ow ever, target d evice VDEVs are not m anaged by FAST VP.
TimeFinder VP Sna p
The sou rce d evice in a Tim eFind er VP Snap session can be m anaged by
FAST VP. Target d evices m ay also be m anaged by FAST VP, how ever,
extent allocations that are shared by m u ltip le target d evices w ill not be
m oved .
Open Replica tor for Symmetrix
The control d evice in an Op en Rep licator session, p u sh or p u ll, can have
extents m oved by FAST VP.
Virtua l Provisioning
All thin d evices, w hether u nd er FAST VP control or not, m ay only be
bou nd to a single thin p ool. All host-w rite-generated allocations, or u serrequ ested p re-allocations, are p erform ed to this p ool. FAST VP d ata
m ovem ents d o not change the bind ing inform ation for a thin d evice.
It is p ossible to change the bind ing inform ation for a thin d evice w ithou t
changing any of the cu rrent extent allocations for the d evice. H ow ever,
w hen rebind ing a d evice that is u nd er FAST VP control, the th in p ool the
d evice is being re-bou nd to m u st belong to one of the VP tiers contained
in the p olicy that the d evice is associated w ith.
Virtua l Provisioning spa ce recla ma tion
Sp ace reclam ation m ay be ru n against a thin d evice u nd er FAST VP
control. H ow ever, d u ring the sp ace reclam ation p rocess, su b-LUN
p erform ance m etrics are not u p d ated , and d ata m ovem ents are not
p erform ed .
N ote: If FAST VP is actively m oving extents of a d ev ice, a request to reclaim
space on that d evice w ill fail. Prior to issuing the space reclam ation task , the
d evice should first be pinned. This suspend s any active FAST VP d ata
m ovem ents for the d evice and allow s the request to succeed .

Virtua l Provisioning T10 unma p


Unm ap com m and s can be issu ed to thin d evices u nd er FAST VP control.
The T10 SCSI unmap com m and for thin d evices ad vises a target thin
d evice that a range of blocks are no longer in u se. If this range covers a
fu ll thin d evice extent, that extent can be d eallocated and the free sp ace
retu rned to the p ool.
If the unmap com m and range covers only som e tracks in an extent, those
tracks are m arked N ever Written by H ost (N WBH ). The extent is not
FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

15

Product and feature interoperability

d eallocated ; how ever those tracks w ill not have to be retrieved from d isk
shou ld a read requ est be p erform ed . Instead , the Sym m etrix array
im m ed iately retu rns all zeros.
Virtua l Provisioning pool ma na gement
Data d evices m ay be ad d ed to or rem oved from a thin p ool that is
inclu d ed in the FAST VP tier. Data m ovem ents related to FAST VP, into
or ou t of the thin p ool, continu e w hile the d ata d evices are being
m od ified .
In the case of ad d ing d ata d evices to a thin p ool, au tom ated p ool
rebalancing m ay be ru n. Sim ilarly, w hen d isabling and rem oving d ata
d evices from the p ool, they d rain their allocated tracks to other enabled
d ata d evices in the p ool.
While both d ata d evice d raining and au tom ated p ool rebalancing m ay be
active in a thin p ool that is inclu d ed in a VP tier, both of these p rocesses
m ay affect p erform ance of FAST VP d ata m ovem ents.
Virtua l LUN VP mobility
A thin d evice u nd er FAST VP control m ay be m igrated u sing VLUN VP.
Su ch a m igration resu lts in all allocated extents of the d evice being
m oved to a single thin p ool.
While the m igration is in p rogress, no FAST VP-related d ata m ovem ents
are p erform ed . H ow ever, once the m igration is com p lete, all allocated
extents of the thin d evice w ill be available to be retiered .
To p revent the m igrated d evice from being retiered by FAST VP
im m ed iately follow ing the m igration, it is recom m end ed that the d evice
first be p inned . To re-enable FAST VP-related d ata m ovem ents, the
d evice can later be u np inned .
FAST
Both FAST and FAST VP m ay coexist w ithin a single Sym m etrix array.
FAST only p erform s fu ll d evice m ovem ents of non-thin d evices. As su ch,
there is no im p act to FAST VPs m anagem ent of thin d evices.
Both FAST and FAST VP share som e configu ration p aram eters. These
are:

Workload Analysis Period (WAP)

Initial Analysis Period (IAP)

Perform ance tim e w ind ow s

Symmetrix Optimizer
Sym m etrix Op tim izer op erates only on non -thin d evices. As a resu lt,
there is no im p act on FAST VPs m anagem ent of thin d evices.
16

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Planning and design considerations


Both Op tim izer and FAST VP share som e configu ration p aram eters.
These are:

Workload Analysis Period (WAP)

Initial Analysis Period (IAP)

Perform ance tim e w ind ow s

Dyna mic Ca che Pa rtitioning (DCP)


Dynam ic Cache Partitioning can be u sed to isolate storage hand ling of
d ifferent ap p lications. As d ata m ovem ents u se the sam e cache p artition
as the ap p lication, m ovem ents of d ata on behalf of one ap p lication d o
not affect the p erform ance of ap p lications that are not sharing the sam e
cache p artition.
Auto-provisioning Groups
Storage grou p s created for the p u rp oses of Au to-p rovisioning m ay also
be u sed for FAST VP. H ow ever, w hile a d evice m ay be contained in
m u ltip le storage grou p s for the p u rp oses of Au to-p rovisioning, it m ay
only be contained in one storage grou p that is associated w ith a FAST
p olicy (DP or VP).
Shou ld a storage grou p contain a m ix of d evice typ es, thin and non -thin,
only the d evices m atching the typ e of FAST p olicy it is associated w ith
are m anaged by FAST.
If it is intend ed that both d evice typ es in an Au to-p rovisioning storage
grou p are to be m anaged by FAST and FAST VP, resp ectively, then
sep arate storage grou p s need to be created . A storage grou p w ith the
non-thin d evices m ay then be associated w ith a p olicy containing DP
tiers. A sep arate storage grou p containing the thin d evices w ill be
associated w ith a p olicy containing VP tiers.

Pla nning a nd design considera tions


The follow ing sections d etail best p ractice recom m end ations for
p lanning the im p lem entation of a FAST VP environm ent .
The best p ractices d ocu m ented are based on featu res available in
Enginu ity 5876.82.57, Solu tions Enabler 7.4, Sym m etrix Managem ent

Console 7.3.3, and Unisp here for VMAX 1.0.


FAST VP configura tion pa ra meters
FAST VP has m u ltip le configu ration p aram eters that control its behavior.
These inclu d e settings to d eterm ine the effect of p ast w orkload s on d ata
analysis, qu ality of service for d ata m ovem ents, and p ool sp ace to be
FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

17

Planning and design considerations

reserved for non-FAST VP activities. Also, p erform ance collection and


d ata m ovem ent tim e w ind ow s can be d efined .
The follow ing sections d escribe best p ractice recom m end ations for each
of these configu ration p aram eters.
N ote: For m ore inform ation on each of these configuration param eters, refer
to the Implementing Fully A utomated Storage Tiering for V irtual Pools (FA ST V P)
for EM C Symmetrix V M A X Series A rrays technical note available at
http://powerlink.emc.com.
Performance time window

The p erform ance tim e w ind ow s sp ecify d ate and tim e ranges w hen
p erform ance m etrics shou ld be collected , or not collected , for the
p u rp oses of FAST VP p erform ance analysis. By d efau lt, p erform ance
m etrics are collected 24 hou rs a d ay, every d ay. Tim e w ind ow s m ay be
d efined , how ever, to inclu d e only certain d ays or d ays of the w eek, as
w ell as exclu d e other tim e p eriod s.
As a best p ractice, the d efau lt p erform ance w ind ow sh ou ld be left
u nchanged . H ow ever, if there are extend ed p eriod s of tim e w hen the
w orkload s m anaged by FAST VP are not active, these tim e p eriod s
shou ld be exclu d ed .
N ote: The perform ance tim e w ind ow is applied system -w id e. If m ultiple
applications are active on the array, but active at d ifferent tim es, then the
d efault perform ance tim e w ind ow behavior should be left unchanged .
Da ta movement time window

Data m ovem ent tim e w ind ow s are u sed to sp ecify d ate and tim e ranges
w hen d ata m ovem ents are allow ed , or not allow ed , to be p erform ed .
The best p ractice recom m end ation is that, at a m inim u m , the d ata
m ovem ent w ind ow shou ld allow d ata m ovem ents for the sam e p eriod of
tim e that the p erform ance tim e w ind ow s allow d ata collection. This
allow s FAST VP to react m ore qu ickly and m ore d ynam ically to any
changes in w orkload that occu r on the array.
Unless there are sp ecific tim e p eriod s to avoid d ata m ovem ents, d u ring a
backu p w ind ow , for exam p le, it m ay be ap p rop riate to set the d ata
m ovem ent w ind ow to allow FAST VP to p erform m ovem ents 24 hou rs a
d ay, every d ay.

18

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Planning and design considerations


N ote: If there is a concern about possible im pact of d ata m ovem ents
occurring d uring a prod uction w orkload then the FAST VP Relocation Rate
can be used to m inim ize this im pact.
Workload Analysis Period

The Workload Analysis Period (WAP) d eterm ines the d egree to w hich
FAST VP m etrics are influ enced by recent host activity, and also less recent host activity, that takes p lace w hile the p erform ance tim e w ind ow
is consid ered op en.
The longer the tim e d efined in the WAP, the greater the am ou nt of
w eight is assigned to less recent host activity.
The best p ractice recom m end ation for the WAP is to u se the d efau lt
valu e of 168 hou rs (1 w eek).
Initial Analysis Period

The Initial Analysis Period (IAP) d efines the m inim u m am ou nt of tim e a


thin d evice shou ld be u nd er FAST VP m anagem ent before any
p erform ance-related d ata m ovem ents shou ld be ap p lied .
This p aram eter shou ld be set to a long enou gh valu e so as to allow
su fficient d ata sam p les for FAST VP to establish a good characterization
of the typ ical w orkload on that d evice.
At the initial d ep loym ent of FAST VP, it m ay m ake sense to set the IAP
to 168 hou rs (1 w eek) to ensu re that a typ ical w eekly w orkload cycle is
seen. H ow ever, once FAST VP d ata m ovem ent has begu n, you m ay
red u ce the IAP to 24 hou rs (1 d ay), w hich allow s the new ly associated
d evices to benefit from FAST VP m ovem ent recom m end ations m ore
qu ickly.
FAST VP Relocation Ra te

The FAST VP Relocation Rate (FRR) is a qu ality of service (QoS) setting


for FAST VP. The FRR affects the aggressiveness of d ata m ovem ent
requ ests generated by FAST VP. This aggressiveness is m easu red as the
am ou nt of d ata that is requ ested to be m oved at any given tim e, and the
p riority given to m oving the d ata betw een p ools.
Setting the FRR to the m ost aggressive valu e, 1, cau ses FAST VP to
attem p t to m ove the m ost d ata it can, as qu ickly as it can. Dep end ent on
the am ou nt of d ata to be m oved , an FRR of 1 is m ore likely to cau se
im p act to host I/ O resp onse tim es, d u e to the ad d itional back -end
overhead being generated by the FAST VP d ata m ovem ents. H ow ever,
the d istribu tion of d ata across tiers is com p leted in a shorter p eriod of
tim e.
Setting the FRR to the least aggressive valu e, 10, cau ses FAST VP to
FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

19

Planning and design considerations

greatly red u ce the am ou nt of d ata that is m oved , and the p ace at w hich it
is m oved . This setting cau ses no im p act to host resp onse tim e, bu t the
final d istribu tion of d ata takes longer.
Figu re 2 show s the sam e w orkload , 1,500 IOPS of typ e OLTP2, being ru n
on an environm ent containing tw o FAST VP tiers, Fibre Channel (FC)
and Enterp rise Flash (EFD). The sam e test w as carried ou t w ith three
sep arate relocation rates: 1, 5, and 8.
With a FRR of 1, an initial increase in resp onse tim e is seen at the tw o hou r m ark, w hen FAST VP d ata m ovem ent began, w hile no increase in
resp onse tim e is seen w hen the relocation rate is set to 8. H ow ever, the
stead y state for the resp onse tim e is seen in a m u ch shorter p eriod of
tim e for the low er, m ore aggressive, setting.

Figure 2. Example workload with varying relocation rates


The d efau lt valu e for the FRR is 5. H ow ever, the best p ractice
recom m end ation for the initial d ep loym ent of FAST VP is to start w ith a
m ore conservative valu e for the relocation rate, p erhap s 7 or 8. The
reason for this is that w hen FAST VP is first enabled , the am ou nt of d ata
to be m oved is likely to be greater , com p ared to w hen FAST VP has been
ru nning for som e tim e.
At a later d ate, w hen it is seen that the am ou nt of d ata m ovem ent s
betw een tiers is less, the FRR can be set to a m ore aggressive level,
20

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Planning and design considerations


p ossibly 2 or 3. This allow s FAST VP to ad ju st to sm all changes in
w orkload m ore qu ickly.
Pool Reserved Ca pacity

The Pool Reserved Cap acity (PRC) reserves a p ercentage of each p ool
inclu d ed in a VP tier for non -FAST VP activities. When the p ercentage of
u nallocated sp ace in a thin p ool is equ al to the PRC, FAST VP no longer
p erform s d ata m ovem ents into that p ool.
The PRC can be set both as a system -w id e setting and for each ind ivid u al
p ool. If the PRC has not been set for a p ool, or the PRC for the p ool has
been set to NONE, then the system -w id e setting is u sed .
For the system -w id e setting, the best p ractice recom m end ation is to u se
the d efau lt valu e of 10 p ercent.
For ind ivid u al p ools, if thin d evices are bou nd to the p ool, the best
p ractice recom m end ation is to set the PRC based on the low est allocation
w arning level for that thin p ool. For exam p le, if a w arning is triggered
w hen a thin p ool has reached an allocation of 80 p ercent of its cap acity,
then the PRC shou ld be set to 20 p ercent. This ensu res that the rem aining
20 p ercent of the p ool is only u sed for new host-generated allocations,
and not FAST VP d ata m ovem ents.
If no thin d evices are bou nd to the p ool, or are going to be bou n d , then
the PRC shou ld be set to the low est p ossible valu e, 1 p ercent.
VP Allocation by FAST Policy

The VP allocation by FAST p olicy featu re allow s new allocations to com e


from any of the thin p ools inclu d ed in the FAST VP p olicy that the thin
d evice is associated w ith.
With this featu re enabled , FAST VP attem p ts to allocate new w rites in
the m ost ap p rop riate tier first, based on available p erform ance m etrics. If
no p erform ance m etrics are available, the allocation is attem p ted in the
p ool the d evice is bou nd to.
If the p ool initially chosen to allocate the d ata is fu ll, FAST VP then look s
to other p ools contained w ithin the FAST VP p olicy and allocate from
there. As long as there is sp ace available in at least one of the p ools
w ithin the p olicy, all new extent allocations w ill be su ccessfu l.
The allocation by p olicy featu re is enabled at the Sym m etrix array level
and ap p lies to all allocations for all d evices m anaged by FAST VP. The
featu re is either enabled or d isabled (the d efau lt setting is d isabled ).
When d isabled , new allocations only com e from the p ool the thin d evice
is bou nd to.
As a best p ractice, it is recom m end ed that VP allocation by FAST p olicy

FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

21

Planning and design considerations

be enabled .
N ote: For m ore inform ation on the d ecision m aking process of the VP
allocation by FAST policy feature, refer to the A dvance FA ST V P features
section of the Implementing Fully A utomated Storage Tiering for V irtual Pools
(FA ST V P) for EM C Symmetrix V M A X Series A rrays technical note.

FAST VP tier configura tion


A Sym m etrix storage tier is a sp ecification of a set of resou rces of the
sam e d isk technology typ e (EFD, FC/ SAS, SATA, or FTS storage)
com bined w ith a given RAID p rotection typ e (RAID 1, RAID 5, RAID 6,
or Unp rotected ), and the sam e em u lation (FBA or CKD).
N ote: The unprotected RAID type m ay only be applied to a tier resid ing on
an FTS-connected storage array.

FAST VP tiers can contain betw een one and fou r thin storage p ools . Each
thin p ool m u st contain d ata d evices configu red on the sam e d rive
technology and em u lation (and the sam e rotational sp eed , in the case of
FC, SAS, and SATA d rives). H ow ever, tw o or m ore thin p ools containing
d ata d evices configu red on rotating d rives of d ifferent sp eed s m ay be
com bined in a single VP tier.
Drive-size considerations

Drive size is not a factor w hen ad d ing d ata d evices to a thin p ool. For
exam p le, d ata d evices configu red on 300GB FC 15k d rives can coexist in
a p ool w ith d ata d evices configu red on 600GB FC 15k d rives.
H ow ever, w hen p lanning to have d ata d evices on d ifferent d rive s izes
exist in the sam e storage tier, it is recom m end ed to create tw o sep arate
p ools for each d rive size, and then com bine those tw o p ools into a single
tier.
N ote: For m ore inform ation on best practices for configuring thin pools, refer
to the Best Practices for Fast, Simple Capacity A llocation with EM C Symmetrix
V irtual Provisioning Technical N ote available at http:/ / pow erlink.em c.com .
External tiers

When creating a tier on an external array u sing FTS, it is recom m end ed


that the eDisks be configu red on a single array. The eDisks shou ld also
be configu red on sim ilar d rives w ithin that external array.
External tiers can only be configu red on storage configu red for external
p rovisioning. Encap su lated storage is n ot su p p orted by FAST VP.

22

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Planning and design considerations


N ote: For m ore inform ation on best practices for configuring eDisks, refer to
the Design and Implementation Best Practices for EM C Symmetrix Federated Tiered
Storage (FTS) technical note available at http:/ / pow erlink.em c.com .

FAST VP policy configura tion


A FAST VP p olicy grou p s betw een one and three VP tiers and assigns an
u p p er-u sage lim it for each storage tier. The u p p er lim it sp ecifies the
m axim u m am ou nt of cap acity of a storage grou p associated w ith the
p olicy can resid e on that p articu lar tier. The u p p er cap acity u sage lim it
for each storage tier is sp ecified as a p ercentage of the configu red , logical
cap acity of the associated storage grou p .

Figure 3. Storage tier, policy, storage group association


The u sage lim it for each tier m u st be betw een 1 p ercent and 100 p ercent.
When com bined , the u p p er u sage lim it for all thin storage tiers in the
p olicy m u st total at least 100 p ercent, bu t m ay be greater than 100
p ercent.
Tier ranking

FAST VP ranks tiers w ithin a p olicy based on know n p erform ance


m od els. For internal tiers, FAST VP ord ers the three available
technologies in term s of p erform ance cap abilities in d escend ing ord er :
EFD, Fibre Channel/ SAS, and SATA.
FAST VP has no m echanism for d eterm ining the p otential p erform ance
of an external, FTS tier. As a resu lt, any external tier inclu d ed in a p olicy
is consid ered to be the low est tier in that p olicy.
Tier usa ge limits

Creating a p olicy w ith a total u p p er u sage lim it greater than 100 p ercent
allow s flexibility w ith the configu ration of a storage grou p , w hereby d ata
m ay be m oved betw een tiers w ithou t necessarily having to m ove a
corresp ond ing am ou nt of other d ata w ithin the sam e storage grou p .
The id eal FAST VP p olicy w ou ld be to sp ecify 100 p ercent for each of the
inclu d ed tiers. Su ch a p olicy w ou ld p rovid e the greatest am ou nt of
flexibility to an associated storage grou p , as it w ou ld allow 100 p ercent
FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

23

Planning and design considerations


of the storage grou p s cap acity to be p rom oted or d em oted to any tier
w ithin the p olicy.
While id eal, op erationally it m ay not be ap p rop riate to d ep loy the
100/ 100/ 100 p olicy. There m ay be reasons to lim it access to a p articu lar
tier w ithin the array.
As an exam p le, it m ay be ap p rop riate to lim it the am ou nt of a storage
grou p s cap acity that can be p laced on EFD. This m ay be u sed to p revent
one single storage grou p , or ap p lication, from consu m ing all of the EFD
resou rces. In this case, a p olicy containing ju st a sm all p ercentage for
EFD w ou ld be recom m end ed .
Sim ilarly, it m ay be ap p rop riate to restrict the am ou nt of SATA cap acity
a storage grou p m ay u tilize. Som e ap p lications, w hich can becom e
inactive from tim e to tim e, m ay requ ire a m inim u m level of p erform ance
w hen they becom e active again. For su ch ap p lications, a p olicy exclu d ing
the SATA tier cou ld be ap p rop riate.
The best w ay to d eterm ine ap p rop riate p olicies for a FAST VP
im p lem entation is to exam ine the w orkload skew for the ap p lication
d ata to be m anaged by FAST VP. The w orkload skew d efines an
asym m etry in d ata u sage over tim e. This m eans a sm all p ercentage of the
d ata on the array m ay be servicing the m ajority of the w orkload on the
array. One tool that p rovid es insight into this w orkload skew is Tier
Ad visor.
Tier Advisor

Tier Ad visor is a u tility available to EMC technical staff that estim ates
the p erform ance and cost of m ixing d rives of d ifferent technology typ es
(EFD, FC, and SATA) w ithin Sym m etrix VMAX Series storage arrays.
Tier Ad visor can exam ine p erform ance d ata collected from Sym m etrix,

VN X , or CLARiiON storage arrays and d eterm ine the w orkload skew


at the fu ll LUN level. It can also estim ate the w orkload skew at the su b LUN level.
With this inform ation, Tier Ad visor can m od el an op tim al storage array
configu ration by enabling the ability to interactively exp erim ent w ith
d ifferent storage tiers and storage p olicies, u ntil achieving the d esired
cost and p erform ance p references.
Thin device binding
Each thin d evice, w hether u nd er FAST VP control or not, m ay only be
bou nd to a single thin p ool. By d efau lt, all host w rite generated
allocations, or u ser-requ ested p re-allocations, are p erform ed from this
p ool.

24

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Planning and design considerations


From an ease-of-m anagem ent and rep orting p ersp ective, it is
recom m end ed that all thin d evices be bou nd to a single p ool w ithin the
Sym m etrix array.
N ote: FAST VP d ata m ovem ents d o not change the bind ing inform ation for a
thin d evice.

In d eterm ining the ap p rop riate p ool, both p erform ance requ irem ents
and cap acity m anagem ent shou ld be taken into consid eration , as w ell as
the u se of thin d evice p reallocation and the system w rite p end ing lim it.
N ote: Unless there is a very specific perform ance need , it is not
recom m end ed to bind thin d evices, und er FAST VP control, to the EFD tier.
Performance considera tion

With VP allocation by FAST p olicy enabled , FAST VP attem p t s to


allocate new extents in the m ost ap p rop riate tier. This is based on
available p erform ance m etrics for the thin d evice being allocated . Shou ld
p erform ance m etrics not be available, the allocation com es from the p ool
the thin d evice is bou nd to.
As su ch, the best p ractice recom m end ation is to bind all thin d evices to a
p ool w ithin the second highest tier in the p olicy.
In a three-tier configu ration (EFD, FC, and SATA), this w ou ld im p ly the
Fibre Channel tier. In a FC and SATA configu ration, this w ou ld im p ly
the SATA tier. Once the d ata has been w ritten, and sp ace has been
allocated in the p ool, FAST VP then m akes the d ecision to p rom ote or
d em ote the d ata as ap p rop riate.
Ca pacity management considera tion

Bind ing all thin d evices to a single p ool u ltim ately cau se s that single
p ool to be oversu bscribed . If the allocation by p olicy featu re is not
enabled , this cou ld p otentially lead to issu es as the p ool fills u p . H ost
w rites to u nallocated areas of a thin d evice w ill fail if there is insu fficient
sp ace in the bou nd p ool.
In an EFD, FC, SATA configu ration, if the FC tier is significan tly sm aller
than the SATA tier, bind ing all thin d evices to the SATA tier red u ces the
likelihood of the bou nd p ool filling u p .
If p erform ance need s requ ire the thin d evices to be bou nd to FC, the Pool
Reserved Cap acity, the FAST VP p olicy configu ration , or a com bination
of both, can be u sed to alleviate a p otential p ool-fu ll cond ition.

FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

25

Planning and design considerations

N ote: Enabling VP allocation by FAST policy on the Sym m etrix VMAX Series
array greatly alleviates the cap acity-m anagem ent consid eration .
Prealloca tion

A w ay to avoid w rites to a thin d evice failing d u e to a p ool being fu lly


allocated is to p reallocate the thin d evice w hen it is bou nd . H ow ever,
p erform ance requ irem ents of new ly w ritten d ata shou ld be consid ered
p rior to u sing p reallocation.
When FAST VP p erform s d ata m ovem ents, only allocated extents are
m oved . This ap p lies not only to extents allocated as the resu lt of a host
w rite, bu t also to extents that have been p reallocated . These p reallocated
extents w ill be m oved even if no d ata has yet been w ritten to them .
N ote: When m oving preallocated , but unw ritten, extents, no d ata is actually
m oved . The pointer for the extent is sim ply red irected to the pool in the
target tier.

Preallocated , bu t u nw ritten, extents show as inactive and , as a resu lt, are


d em oted to the low est tier inclu d ed in the associated FAST VP p olicy.
When these extents are eventu ally w ritten to, the w rite p erform ance w ill
be that of the tier it has been d em oted to.
A best p ractice recom m end ation is to not p reallocate th in d evices
m anaged by FAST VP. Preallocation shou ld only be u sed selectively for
those d evices that can never tolerate a w rite failu re d u e to a fu ll p ool.
System write pending limit

FAST VP is d esigned to throttle back d ata m ovem ents, both p rom otions
and d em otions, as the w rite p end ing cou nt ap p roaches the system w rite
p end ing lim it. This throttling gives an even higher p riority to host I/ O to
ensu re that tracks m arked as w rite p end ing are d estaged ap p rop riately.
N ote: By d efault, the system w rite pend ing lim it on a Sym m etrix VMAX
Series array is set to 75 percent of the available cache.

If the w rite p end ing cou nt reaches 60 p ercent of the w rite p end ing lim it,
FAST VP d ata m ovem ents stop . As the w rite p end ing cou nt d ecreases
below this level, d ata m ovem ents au tom atically restart.
A very bu sy w orkload ru nning on SATA d isks, w ith SATA d isks at, or
near, 100 p ercent u tilization, cau sing a high w rite p end ing cou nt,
im p acts FAST VP from p rom oting active extents to FC and / or EFD tiers.
In an environm ent w ith a high w rite w orkload , it is recom m end ed to
bind thin d evices to a p ool in the FC tier.

26

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Planning and design considerations


Migration

When p erform ing a m igration to thin d evices, it is p ossible that the thin
d evices m ay becom e fu lly allocated as a resu lt of the m igration. As su ch,
the thin d evices being m igrated to shou ld be bou nd to a p ool that has
su fficient cap acity to contain the fu ll cap acity of each of the d evices.
Virtu al Provisioning zero sp ace reclam ation can be u sed follow ing the
m igration to d eallocate zero d ata cop ied d u ring the m igration.
Alternatively, the front-end zero d etection cap abilities of SRDF and
Op en Rep licator can be u sed d u ring the m igration.
Rebinding a thin device

It is p ossible to change the bind ing inform ation for a thin d evice w ithou t
m oving any of the cu rrent extent allocations for the d evice. This is d one
by a p rocess called rebind ing.
Rebind ing a thin d evice increases the su bscrip tion level of the p ool the
d evice is bou nd to, and d ecrease the su bscrip tion level of the p ool it w as
p reviou sly bou nd to. H ow ever, the allocation levels in both p ools rem ain
u nchanged .
N ote: When rebind ing a d evice that is und er FAST VP control, the thin pool
the d evice is being re-bound to m ust belong to one of the VP tiers contained
in the policy the d evice is associated w ith.

Thin pool oversubscription


Thin p ool oversu bscrip tion allow s an organization to p resent larger than
need ed d evices to hosts and ap p lications w ithou t having to p u rchase
enou gh p hysical d rives to fu lly allocate all of the sp ace rep resented by
the thin d evices.
N ote: For m ore inform ation on oversubscription, refer to the Best Practices for
Fast, Simple Capacity A llocation with EM C Symmetrix V irtual Provisioning
technical note available at http :/ / pow erlink.em c.com .

In a FAST VP configu ration, the cap acity available for thin d evices is
now sp read across m u ltip le p ools. Even if there is no p lan to
oversu bscribe the available cap acity in the Sym m etrix array , there
typ ically is insu fficient sp ace in a single tier to accom m od ate the
configu red thin d evice cap acity.
By follow ing the p reviou s recom m end ation, bind ing all thin d evices
being m anaged by FAST VP to a single thin p ool inherently cau se s that
p ool to be oversu bscribed . As a resu lt, the over-su bscrip tion lim it for that
p ool need s to be set to a valu e greater than 100 p ercent.

FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

27

Planning and design considerations

Available capacity

In ord er to d eterm ine at w hat level to set the over -su bscrip tion lim it, the
total cap acity available to d evices u nd er the control of FAST VP shou ld
first be calcu lated .
If the VP allocation by FAST p olicy featu re is enabled , then 100 p ercent
of the cap acity of each p ool w ithin the p olicy is available.
If the allocation by p olicy featu re is not enabled , the follow ing p oints
shou ld be consid ered :

For p ools w ith thin d evices bou nd , 100 p ercent of the


cap acity is available.

For p ools w ith no thin d evices bou nd , 100 p ercent of the


p ool, less the cap acity reserved by the PRC, is available.

N ote: The pool reserved capacity value only affects FAST VP m ovem ents into
the pool; the PRC d oes not affect the ability for the thin d evices to allocate
extents w ithin the pool.
Over-subscription limits

After d eterm ining the cap acity available to FAST VP, an over su bscrip tion lim it can then be calcu lated for the p ool d evices that are
going to be bou nd to it.
To ensu re the configu red cap acity of the array is not oversu bscribed , the
lim it can be calcu lated by d ivid ing the cap acity of the thin p ool being
u sed for bind ing into the available cap acity of all the p ools. This valu e is
then m u ltip lied by 100 to get a p ercent valu e.
For exam p le, consid er a configu ration w ith a 1TB EFD p ool, a 5 TB FC
p ool, and a 10TB SATA p ool. The total available cap acity is 16TB. If all
thin d evices are bou nd to FC, the oversu bscrip tion lim it cou ld be set to
320% (16/ 5)*100.
This valu e can be set higher if the intention is to initially oversu bscribe
the configu red p hysical cap acity of the array , and then ad d storage on an
as-need ed basis.
For thin p ools w here d evices w ill never be bou nd , the su bscrip tion lim it
can be set to 0 p ercent. This p revents any accid ental bind ing or m igration
to that p ool.
RAID protection considera tions
When d esigning a Virtu al Provisioning configu ration, and p articu larly
w hen choosing a corresp ond ing RAID p rotection strategy, both d evice-

28

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Planning and design considerations


level p erform ance and availability im p lications shou ld be carefu lly
consid ered .
N ote: For m ore inform ation on these consid erations, refer to the Best Practices
for Fast, Simple Capacity A llocation with EM C Symmetrix V irtual Provisioning
technical note available at http :/ / pow erlink.em c.com .

FAST VP d oes not change these consid erations and recom m end ations
from a p erform ance p ersp ective. What FAST VP d oes change, how ever,
is that a single thin d evice can now have its d ata sp read across m u ltip le
tiers of varying RAID p rotection and d rive technology w ithin the array.
Becau se of this, the availability of an ind ivid u al thin d evice is not based
ju st on the availability characteristics of the thin p ool the d evice is bou nd
to. Instead , availability is based on the characteristics of the tier w ith the
low est availability.
While p erform ance and availability requ irem ents u ltim ately d eterm ine
the configu ration of each tier w ithin the Sym m etrix array, it is
recom m end ed , as a best p ractice, to choose RAID 1 or RAID 5 p rotection
on EFDs. The faster rebu ild tim es of EFDs p rovid e higher availability for
these p rotection schem es on that tier.
Also, it is recom m end ed to u se either RAID 1 or RAID 6 on the SATA
tier. This is d u e to the slow er rebu ild tim es of the SATA d rives
(com p ared to EFD and FC), and the increased chance of a d u al-d rive
failu re, lead ing to d ata u navailability w ith RAID 5 p rotection .
For the FC tier, RAID 1 is the recom m end ed p rotection level. Mirrored
d ata d evices on FC p ools p rovid e a higher level of p erform ance than
both RAID 5 and RAID 6, p articu larly for w rite w orkload . Availability of
RAID 1, in regard to a d u al-d rive failu re, is also greater than RAID 5. To
obtain the best availability nu m bers for RAID 1 on FC, the u se of low er
cap acity d rives is recom m end ed .
N ote: For new environm ents being configured in anticipation of
im plem enting FAST VP, or for existing environm ents having ad d itional tiers
ad d ed , it is highly recom m end ed that EMC representatives be engaged to
assist in d eterm ining the appropriate RAID protection schem es for each tier.

Drive configura tion


For m ost cu stom er configu rations, the best p ractice configu ration
gu id elines recom m end an even, balanced d istribu tion of p hysical d isks
across the d isk ad ap ters (DAs) and DA CPUs.
This is of p articu lar relevance for EFDs, w hich are each able to su p p ort
thou sand s of I/ Os p er second , and , therefore, are able to create a load on
FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

29

Planning and design considerations

the DA equ ivalent to that of m u ltip le hard d isk d rives.


An even d istribu tion of I/ O across all DA CPUs is op tim al to m axim ize
their cap ability, and the overall cap ability of the Sym m etrix array.
H ow ever, there are scenarios w here it is not ap p rop riate to evenly
d istribu te d isk resou rces. An exam p le of this is w hen the cu stom er
d esires p artitioning and isolation of d isk resou rces to sep arate cu stom er
environm ents and w orkload s w ithin the VMAX Series array.
Generally, it is ap p rop riate to configu re m ore, sm aller d rives, than few er,
larger d rives for both EFD and FC tiers. Doing so sp read s I/ O load as
w id e as p ossible across the Sym m etrix back-end .
For exam p le, on a 2-engine VMAX Series array w ith 16 DAs, if the EFD
raw cap acity requ irem ent is 3.2 TB, it w ou ld be m ore op tim al to
configu re 16 x 200 GB EFDs than 8 x 400 GB EFDs, as each DA cou ld
have one EFD configu red on it.
Stora ge group priority
When a storage grou p is associated w ith a FAST p olicy, a p riority valu e
m u st be assigned to the storage grou p . This p riority valu e can be
betw een 1 and 3, w ith 1 being the highest p riority . The d efau lt is 2.
When m u ltip le storage grou p s are associated w ith FAST VP p olicies, the
p riority valu e is u sed w hen the d ata contained in the storage grou p s is
com p eting for the sam e resou rces on one of the FAST VP tiers. Storage
grou p s w ith a higher p riority are given p reference w hen d ecid ing w hich
d ata need s to be m oved to another tier.
The best p ractice recom m end ation is to u se the d efau lt p riority of 2 for
all storage grou p s associated w ith FAST VP p olicies. These valu es m ay
then be m od ified if it is seen, for exam p le, that a high-p riority
ap p lication is not getting su fficient resou rces from a higher tier.
SRDF
FAST VP has no restrictions in its ability to m anage SRDF d evices,
how ever, w hat m u st be consid ered is that d ata m ovem ents are restricted
to the array u p on w hich FAST VP is op erating. By d efau lt, there is no
coord ination of d ata m ovem ents; FAST VP acts ind ep end ently on both
the local and rem ote arrays. H ow ever, enabling FAST VP SRDF
coord ination allow s R1 p erform ance m etrics to be u sed w hen m aking
p rom otion-and -d em otion d ecisions for d ata belonging to an R2 d evice.
N ote: For m ore inform ation on the operation of FAST VP SRDF coord ination ,
refer to the A dvance FA ST VP features section of the Implementing Fully

30

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Planning and design considerations


A utomated Storage Tiering for V irtual Pools (FA ST V P) for EM C Symmetrix
V M A X Series A rrays technical note available at http:/ / pow erlink.em c.com .

As a general best p ractice, FAST VP shou ld be em p loyed for both R1 and


R2 d evices, p articu larly if the rem ote R2 array has also been configu red
w ith tiered storage cap acity. Where p ossible, sim ilar FAST VP tiers and
p olicies shou ld be configu red at each site.
When available, FAST VP SRDF coord ination shou ld be enabled for each
storage grou p containing SRDF d evices that is associated w ith a FAST
VP p olicy.
Each SRDF configu ration , how ever, p resents its ow n u niqu e behaviors
and w orkload s. Prior to im p lem enting FAST VP in an SRDF
environm ent, the inform ation in the follow ing sections shou ld be
consid ered .
N ote: The follow ing sections assum e that SRDF is im plem ented w ith all
Sym m etrix arrays configured for Virtual Provisioning (all SRDF d evices are
thin d evices) and installed w ith the m inim um Enginuity version capable of
running FAST VP (5875.135.91).
FAST VP behavior

For SRDF R1 d evices, FAST VP p rom otes and d em otes extent grou p s
based on the read -and -w rite activity exp erienced on th e R1 d evices.
Meanw hile, by d efau lt, the SRDF R2 d evices typ ically only exp erience
w rite activity d u ring norm al op erations. As a resu lt, FAST VP is likely to
p rom ote only R2 d evice extents that are exp eriencing w rites.
If there are R1 d evice extents that only exp erience read activity, no
w rites, then the corresp ond ing extents on the R2 d evices w ill see no I/ O
activity. This w ill likely lead to these R2 d evice extents being d em oted to
the SATA tier, assu m ing this w as inclu d ed in the FAST VP p olicy.
SRDF coord ination changes this d efau lt behavior by p eriod ically
transm itting FAST VP p erform ance m etrics collected for R1 d evices
across the SRDF link to the corresp ond ing R2 d evices. On the R2 d evice,
the R1 p erform ance m etrics are m erged w ith the actu al R2 m etrics.
Movem ent d ecisions m ad e by FAST VP for these R2 d evices are then
based on the m erged p erform ance m etrics. In this w ay, read activity on
the R1 d evice can be reflected on the R2.
SRDF opera ting mode

EMC best p ractices, for both synchronou s and asynchronou s m od es of


SRDF op eration, recom m end im p lem enting a balanced configu ration on
both the R1 and R2 Sym m etrix arrays. Id eally, d ata on each array w ou ld
FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

31

Planning and design considerations

be located on d evices configu red w ith the sam e RAID p rotection typ e, on
the sam e d rive typ e.
As FAST VP op erates ind ep end ently on each array, and also p rom otes
and d em otes d ata at the su b-LUN level, there is no gu arantee that su ch a
balance m ay be m aintained .
In SRDF synchronou s (SRDF/ S) m od e, host w rites are transferred
synchronou sly from R1 to R2. These w rites are only acknow led ged by
the host w hen the d ata has been received into cache on the rem ote R2
array. These w rites to cache are then d estaged asynchronou sly to d isk on
the R2 array.
N ote: For m ore inform ation on SRDF/ S, see the EM C Solutions Enabler
Symmetrix SRDF Family CLI Product Guide available at
http:/ / pow erlink.em c.com .

In an u nbalanced configu ration, w here the R2 d ata resid es on a low er p erform ing tier than on the R1, p erform ance im p act m ay be seen at the
host if the nu m ber of w rite p end ings bu ild s u p and w rites to cache are
d elayed on the R2 array.
With FAST VP, this typ ically d oes not cau se a p roblem , as the
p rom otions that occu r on the R2 sid e are the resu lt of w rite activity.
Areas of the thin d evices u nd er heavy w rite w orkload are likely to be
p rom oted and m aintained on the higher-p erform ing tiers on the R2
array.
To avoid p otential p roblem s w ith the configu ration becom ing
u nbalanced , it is recom m end ed that FAST VP SRDF coord ination be
enabled in SRDF/ S environm ents.
In SRDF asynchronou s (SRDF/ A) m od e, host w rites are transferred
asynchronou sly in p re-d efined tim e p eriod s or d elta sets. At any given
tim e, there are three d elta sets in effect: The cap tu re set, the
transm it/ receive set, and the ap p ly set.
N ote: For m ore inform ation on SRDF/ A, see the EM C Solutions Enabler
Symmetrix SRDF Family CLI Product Guide available at
http:/ / pow erlink.em c.com .

A balanced SRDF configu ration is m ore im p ortant for SRDF/ A , as d ata


cannot transition from one d elta set to the next u ntil the ap p ly set has
com p leted d estaging to d isk. If the d ata resid es on a low er -p erform ing
tier on the R2 array, com p ared to the R1, then the SRDF/ A cycle tim e
m ay elongate and eventu ally cau se the SRDF/ A session to d rop .

32

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Planning and design considerations


This is sim ilar to SRDF/ S m od e in m ost environm ents, so this m ay not
be a large issu e, as the d ata u nd er w rite w orkload is p rom oted and
m aintained on the higher-p erform ing tiers.
To avoid p otential p roblem s w ith the configu ration becom ing
u nbalanced , it is strongly recom m end ed that FAST VP SRDF
coord ination be enabled in SRDF/ A environm ents.
SRDF/ A DSE (d elta set extension) shou ld be consid ered to p revent
SRDF/ A sessions from d rop p ing in situ ations w here w rites p rop agated
to the R2 array are being d estaged to a low er tier, p otentially cau sing an
elongation of the SRDF/ A cycle tim e.
N ote: For m ore inform ation on SRDF/ DSE, see the Best Practices for EM C
SRDF/A Delta Set Extension technical note available at
http:/ / pow erlink.em c.com .
SRDF failover

As FAST VP w orks ind ep end ently on both the R1 and R2 arrays, it


shou ld be exp ected that the d ata layou t w ill be d ifferent on each sid e if
SRDF coord ination is not enabled . When an SRDF failover op eration is
p erform ed , and host ap p lications are brou ght u p on the R2 d evices, it
shou ld then also be exp ected that the p erform ance characteristics on the
R2 w ill be d ifferent from those on the R1.
In this situ ation it takes FAST VP som e p eriod of tim e to ad ju st to the
change in w orkload and start p rom otion and d em otion activities based
on the m ixed read -and -w rite w orkload .
To better p rep are for a failover, and to shorten the tim e p eriod to achieve
an ad ju stm ent to the new w orkload , FAST VP SRDF coord ination shou ld
be enabled .
N ote: FAST VP perform ance m etrics are only transm itted from R1 to R2.
When failed over, and w ith applications are running on R2 devices,
perform ance m etrics w ill not be sent from R2 to R1.
Personality swa p

An SRDF p ersonality sw ap follow s a sim ilar p attern of behavior to an


SRDF failover scenario. Ap p lications are brou ght u p on the d evices that
w ere form erly R2 d evices.
In ord er for p erform ance m etrics to be transm itted from the new R1
d evices to the corresp ond ing R2 d evices, SRDF coord ination need s to be
enabled on the storage grou p s containing the R1 d evices.
SRDF coord ination can be enabled in ad vance on a storage grou p
containing R2 d evices. H ow ever, the setting only takes effect w hen a
FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

33

Summary and conclusion

p ersonality sw ap is p erform ed , converting the R2 d evices to R1.


SRDF bi-directional

Best p ractice recom m end ations change slightly in a bi-d irectional SRDF
environm ent. In this case, each Sym m etrix array has both R1 and R2
d evices configu red .
With SRDF coord ination enabled , it is p ossible that d ata belonging to an
R2 d evice cou ld d isp lace d ata belonging to an R1 d evice on a higher tier .
This m ay hap p en if the R2 d evices corresp ond ing R1 d evice has a higher
w orkload than the local R1 d evice.
In this scenario, it is recom m end ed to reserve the EFD tier for R1 d evice
u sage. This can be d one by exclu d ing any EFD tiers from the p olicies
associated w ith the R2 d evices.
Shou ld a failover be p erform ed , then the EFD tier can be ad d ed
d ynam ically to the p olicy associated w ith the R2 d evices. Alternatively,
the storage grou p containing the R2 d evices cou ld be reassociated w ith a
p olicy containing EFD.
N ote: This recom m end ation assum es that the low er tiers are of sufficient
capacity and I/ O cap ability to hand le the expected SRDF w rite w orkload on
the R2 d evices.
EFD considerations

If there is a d ifference in the configu ration of the EFD tier on the rem ote
array, then it is recom m end ed not to inclu d e the EFD tier in the FAST VP
p olicies on the R2 array. Exam p les of a configu ration d ifference inclu d e
either few er EFDs or no EFDs. Sim ilarly, if the EFD configu ration on the
R2 array d oes not follow the best p ractice gu id eline of being balanced
across DAs, d o not inclu d e the EFD tier on the R2 sid e.
N ote: This recom m end ation assum es that the low er tiers are of sufficient
capacity and I/ O cap ability to hand le the expected SRDF w rite w orkload on
the R2 d evices.

Summa ry a nd conclusion
EMC Sym m etrix VMAX Fam ily w ith Enginu ity incorp orates a scalable
fabric-interconnect d esign that allow s a storage array to seam lessly grow
from an entry-level configu ration to a 4 PB system . Sym m etrix VMAX
arrays p rovid e p red ictable, self-op tim izing p erform ance and enables
organizations to scale ou t on d em and in p rivate clou d environm ents.

34

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Summary and conclusion


Inform ation infrastru ctu re m u st continu ou sly ad ap t to changing
bu siness requ irem ents. FAST VP au tom ates tiered storage strategies, in
Virtu al Provisioning environm ents, by easily m oving w orkload s
betw een Sym m etrix tiers as p erform ance characteristics change over
tim e. FAST VP p erform s d ata m ovem ents, im p roving p erform ance, and
red u cing costs, all w hile m aintaining vital service levels.
EMC Sym m etrix VMAX FAST VP for Virtu al Provisioning environm ents
au tom ates the id entification of d ata volu m es for the p u rp oses relocating
ap p lication d ata across d ifferent p erform ance/ cap acity tiers w ithin an
array. FAST VP p roactively m onitors w orkload s at both the LUN and
su b-LUN level, in ord er to id entify bu sy d ata that w ou ld benefit from
being m oved to higher-p erform ing d rives. FAST VP also id entifies lessbu sy d ata that cou ld be m oved to higher -cap acity d rives, w ithou t
existing p erform ance being affected .
Prom otion/ d em otion activity is based on p olicies that associate a storage
grou p to m u ltip le d rive technologies, or RAID p rotection schem es, by
w ay of thin storage p ools, as w ell as the p erform ance requ irem ents of the
ap p lication contained w ithin the storage grou p . Data m ovem ent
execu ted d u ring this activity is p erform ed nond isru p tively, w ithou t
affecting bu siness continu ity and d ata availability.
There are tw o com p onents of FAST VP: Sym m etrix Enginu ity and the
FAST controller. Enginu ity is the storage op erating environm ent that
controls com p onents w ithin the array. The FAST controller is a service
that ru ns on the service p rocessor. FAST VP u ses tw o d istinct algorithm s,
one p erform ance-oriented and one cap acity-allocation -oriented , in ord er
to d eterm ine the ap p rop riate tier a d evice shou ld belong to. The
intelligent tiering algorithm consid ers the p erform ance m etrics of all thin
d evices u nd er FAST VP control, and d eterm ines the ap p rop riate tier for
each extent grou p . The allocation com p liance algorithm is u sed to
enforce the p er-tier storage cap acity u sage lim its.
Data m ovem ents execu ted by FAST VP are p erform ed by the VLUN VP
d ata m ovem ent engine, and involve m oving thin d evice extents be tw een
thin p ools w ithin the array. Extents are m oved by m eans of a m ove
p rocess only; extents are not sw ap p ed betw een p ools.
Perform ance d ata for u se by FAST VP is collected and m aintained by
Enginu ity. This d ata is then analyzed by the FAST controller , and the
gu id elines generated for the p lacem ent of thin d evice d ata on the d efined
VP tiers w ithin the array. When collecting p erform ance d ata at the LUN
and su b-LUN level for u se by FAST VP, Enginu ity only collects statistics
related to Sym m etrix back-end activity that is the resu lt of host I/ O.
FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

35

Summary and conclusion

FAST VP p rovid es a nu m ber of p aram eters that can be u sed to tu ne the


p erform ance of FAST VP and to control the aggressiveness of the d ata
m ovem ents. These p aram eters can be u sed to nond isru p tively ad ju st the
am ou nt of tier storage that a given storage grou p is allow ed to u se, or to
ad ju st the m anner in w hich storage grou p s u sing the sam e tier com p ete
w ith each other for sp ace.
FAST VP is fu lly interop erable w ith all Sym m etrix rep lication
technologies: EMC SRDF, EMC Tim eFind er/ Clone, Tim eFind er/ Snap ,
and Op en Rep licator. Any active rep lication on a Sym m etrix d evice
rem ains intact w hile d ata from that d evice is being m oved . Sim ilarly, all
increm ental relationship s are m aintained for the m oved or sw ap p ed
d evices. FAST VP also op erates alongsid e Sym m etrix featu res, su ch as
Sym m etrix Op tim izer, Dynam ic Cache Partitioning, and Au to p rovisioning Grou p s.

36

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Appendix: Best practices quick reference

Appendix: Best pra ctices quick reference


The follow ing p rovid es a qu ick reference to the general best p ractice
recom m end ations for p lanning the im p lem entation of a FAST VP
environm ent.
The best p ractices d ocu m ented are based on featu res available in
Enginu ity 5876.82.57, Solu tions Enabler 7.4, Sym m etrix Managem ent
Console 7.3.3, and Unisp here for VMAX 1.0.
For m ore d etails on these recom m end ations, and other consid erations,
see Planning and design considerations.
FAST VP configura tion pa ra meters
FAST VP inclu d es m u ltip le configu ration p aram eters that control its
behavior. The follow ing sections d escribe best p ractice recom m end ations
for each of these configu ration p aram eters.
Performance time window

Use the d efau lt p erform ance tim e w ind ow to collect p erform ance m etrics
24 hou rs a d ay, every d ay.
Da ta movement time window

Create a d ata m ovem ent w ind ow to allow d ata m ovem ent for the sam e
p eriod of tim e that the p erform ance tim e w ind ow s allow d ata collection.
Workload Analysis Period (WAP)

Use the d efau lt w orkload analysis p eriod of 168 hou rs (7 d ays).


Initial Analysis Period (IAP)

At the initial d ep loym ent of FAST VP, set the initial analysis p eriod to
168 hou rs to ensu re, at a m inim u m , that a typ ical w eekly w orkload cycle
is seen. After this p eriod has p assed , the valu e can be d rop p ed to 24
hou rs.
FAST VP Relocation Ra te

For the initial d ep loym ent of FAST VP, start w ith a conservative valu e
for the relocation rate, p erhap s 7 or 8. At a later d ate the FRR can be
grad u ally low ered to a m ore aggressive level, p ossibly 2 or 3.
Pool Reserved Ca pacity (PRC)

For ind ivid u al p ools w ith bou nd thin d evices, set the PRC based on the
low est allocation w arning level for that thin p ool.
For p ools w ith no bou nd thin d evices, set the PRC to 1 p ercent.
VP Allocation by FAST Policy

VP allocation by FAST p olicy shou ld be enabled .


FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

37

Appendix: Best practices quick reference

FAST VP policy configuration

The id eal FAST VP p olicy w ou ld be 100 p ercent EFD, 100 p ercent FC,
and 100 p ercent SATA. While id eal, op erationally it m ay not be
ap p rop riate to d ep loy the 100/ 100/ 100 p olicy. There m ay be reasons to
lim it access to a p articu lar tier w ithin the array.
The best w ay to d eterm ine the ap p rop riate p olicies for a FAST VP
im p lem entation is to exam ine the w orkload skew for the ap p lication
d ata to be m anaged by FAST VP. This can be d one by u sing a tool su ch
as Tier Ad visor.
Thin device binding

If no ad vance know led ge of the exp ected w orkload on new ly w ritten


d ata is available, the best p ractice recom m end ation is to bind all thin
d evices to a p ool w ithin the second highest tier. In a three -tier
configu ration, this w ou ld im p ly the FC tier.
VP allocation by FAST p olicy shou ld be enabled .
It is not recom m end ed to bind thin d evices, u nd er FAST VP control, to
the EFD tier.
A best p ractice recom m end ation is to not p reallocate thin d evices
m anaged by FAST VP.
RAID protection considera tions

For EFD, choose RAID 5 p rotection .


For FC, choose RAID 1 p rotection.
For SATA, choose RAID 6 p rotection.
Drive configuration

Where p ossible, balance p hysical d rives evenly across DAs. Configu re


m ore, sm aller EFDs, rather than few er, larger EFDs, to sp read I/ O load
as w id e as p ossible.
Stora ge group priority

The best p ractice recom m end ation is to u se the d efau lt p riority of 2 for
all storage grou p s associated w ith FAST VP p olicies.
SRDF

As a general best p ractice, FAST VP shou ld be em p loyed for both R1 and


R2 d evices, p articu larly if the rem ote R2 array has also been configu red
w ith tiered storage cap acity. Sim ilar FAST VP tiers and p olicies shou ld
be configu red at each site.
FAST VP SRDF coord ination shou ld be enabled for storage gr ou p s
containing SRDF R1 d evices.

38

FAST VP fo r EMC Symm etrix VMAX Theo ry a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e

Appendix: Best practices quick reference

Copyright 2012 EMC Corporation. All Rights Reserved.


EMC believes the information in this publication is accurate as of its publication date. The
inform ation is subject to change without notice.
TH E IN FORMATION IN TH IS PUBLICATION IS PROVIDED "AS IS." EMC
CORPORATION MAKES N O REPRESEN TATION S OR WARRANTIES OF AN Y KIND
WITH RESPECT TO THE IN FORMATION IN THIS PUBLICATION , AN D SPECIFICALLY
DISCLAIMS IMPLIED WARRANTIES OF MERCH AN TABILITY OR FITN ESS FOR A
PARTICULAR PURPOSE.
Use, copying, and d istribution of any EMC softw are d escribed in this publication requires
an applicable software license.
For the m ost up -to-date listing of EMC prod uct nam es, see EMC Corporation Trad emarks
on EMC.com .
For the m ost up -to-date regulatory d ocum ent for your prod uct line, go to the Technical
Docum entation and Advisories section on EMC Pow erlink.
All other trad emarks used herein are the property of their respective owners.

FAST VP Theo ry fo r EMC Symm etrix VMAX a nd Best Pra c tic es fo r Pla nning a nd Perfo rm a nc e