Professional Documents
Culture Documents
Water Tube Boiler
Water Tube Boiler
Hospitals
Universities
Manufacturing and
processing facilities
Utilities
Petrochemical
Pulp and paper
Pharmaceuticals
Boiler
Burner
Controls
Fan
Economizer
Sootblowers
Added options (feed pumps,
deaerators, chemical feed systems)
SCR and CO catalyst
Support services
In addition to equipment supply, B&W
offers comprehensive support services,
including:
B&Ws engineering
expertise and complete
project management
skills help to ensure
that a project is right
the rst time and on
time without additional
costs.
B&Ws 2.5 in. (6.35 cm) tubes spaced 1 in. (2.54 cm) apart (tube panel in
background) increase the overall water-cooled tube furnace surface and
reduce the membrane area between the tubes compared with competitors
units that are designed with 2 in. (5.08 cm) tubes spaced 2 in. (5.08 cm)
apart (tube section in foreground). This helps to prevent membrane
thermal cracking and contributes to a faster load response.
Controlled emissions
Capacity
Range*
(lb/h)
Length
8,200
to
40,000
7 ft 7 in.
8 ft 11 in.
9 ft 11 in.
11 ft 3 in.
12 ft 7 in.
13 ft 11 in.
15 ft 3 in.
16 ft 7 in.
17 ft 11 in.
35,000
to
75,000
16 ft 7 in.
17 ft 11 in.
19 ft 3 in.
20 ft 7 in.
21 ft 11 in.
24 ft 7 in.
27 ft 3 in.
FM 9-22
26
30
34
39
43
48
52
57
FM 10-52
57
61
66
70
79
FM 101-88
FM 103-70
79
88
97
70,000
to
100,000
FM 106-79
88
97
FM 117-88
97
100,000
to
155,000
FM 120-97
112
124
FM 160-124
155,000
to
260,000
21 ft 3- 3 16 in.
23 ft 11-316 in.
26 ft 7-316 in.
29 ft 11 in.
23 ft 11-316 in.
26 ft 7-316 in.
29 ft 3-316 in.
26 ft 7-316 in.
29 ft 3-316 in.
29 ft 3-316 in.
33 ft 7-316 in.
37 ft 3-316 in.
37 ft 3-316 in.
Width
Height
Drum
Size
36 in. Steam
Drum
10 ft 2-7 8 in.
12 ft 4 in.
24 in. Lower
Drum
36 in. Steam
Drum
10 ft 10-5 8 in.
13 ft 6 in.
24 in. Lower
Drum
11 ft 2-3 8 in.
11 ft 9 in.
13 ft 9-34 in.
42 in. Steam
Drum
24 in. Lower
Drum
11 ft 9 in.
14 ft 3 in.
11 ft 11-14 in.
15 ft 4-12 in.
12 ft 5- 8 in.
16 ft 10- 2 in.
14 ft 0-38 in.
20 ft 0-12 in.
48 in. Steam
Drum
24 in. Lower
Drum
54 in. Steam
Drum
24 in. Lower
Drum
Steam capacity
Steam pressure
Steam temperature
HCFM
200,000 to 350,000 lb/h
to 825F (441C)
to 900F (482C)
NOTES:
1.All package boilers are of
membrane construction.
METRIC CONVERSIONS:
inches x 25.4 = mm
inches x 2.54 = cm
feet x 0.3048 = m
lb/h x 0.000126 = kg/s
Superheater
(optional)
Division Wall
To Stack or
Economizer
Windbox
Boiler Screen
Boiler Sidewall
Furnace
Furnace Sidewall
2-A
OD=
212"
Membrane
Bar
Scalloped
Seal
Plate
1
4" Thick
Membrane
312"
Furnace Rear
Wall Tubes
A-A
2-B
4
12-Gauge Roof Casing
Steam Drum
Tie Bar
Plate
Casing
Lower Drum
8
Generating
Bank
Tubes
8-A
Brick Holder
4 8"
1
Sootblower
Elements
3"
3"
Generating Bank
9-A
Front Plate
Windbox
Furnace
Burner Wall
Furnace
D Tubes
Steam Outlet
Secondary
Steam Scrubber
Diffuser
Baffle
Type C
Drum Internals
Cyclone
Separator
Steam Outlet
Secondary
Steam Scrubber
Refractory drum
protection safeguards the thicker
wall drums in the
superheater area.
ranging from routine inspections and controls tuning to capacity increase engineering studies, low emissions conversions or
new digital control systems.
10
B&W is dedicated to
generating powerful
solutions in an
environmentally
safe, efcient and
economical manner.
11
www.babcock.com
B&Ws water-tube package
boilers provide dependable
performance for a wide range
of industries and applications.
E101-3155A 2KA0G