You are on page 1of 1

1-CORE XLPE INSULATED PVC JACKETED ARMOURED CABLE 0.

6/1kV 90C, ALUMINUM


PVC Jacket
(Black; UVResistant)

Bedding
Mylar
tape

XLPE
insulation

Specifications

Color-coding

Customer Specification
IEC 60228
IEC 60502 - 1

Clear insulation with black


bedding

Marking
MFD BY PHEPS DODGE
PHILS. 1C _mm AL XLPE
AWA PVC 0.6/1kV 90D
2015

Voltage Rating
0.6/1 (1.2)kV

Aluminum wire
armour

Size

No. of
singles
(nom.)

mm

Conductor
diameter
(approx.)

Insulation
thickness

Insulation
diameter
(approx.)

mm

mm

mm

Compressed
Aluminum
conductor
(AA-1350)

Temperature Rating
90C Normal condition
130C Emergency condition
250C Short-circuit condition

Armour
No. of
singles

Jacket
thickness

Cable
diameter
(approx.)

Cable
weight
(approx.)

DC
resistance
@ 20C

Cond.
reactance

Cable
ampacity

mm

mm

mm

kg / km

/ km

/ km*

A**

Singles
diameter

95

19

12.3

1.1

14.5

35

1.6

1.7

23.6

795

0.320

0.1223

217

120

37

13.9

1.2

16.3

38

1.6

1.8

25.6

927

0.253

0.1183

276

150

37

15.7

1.4

18.5

42

1.6

1.8

27.8

1,096

0.206

0.1152

276

185

37

17.2

1.6

20.4

46

1.6

1.9

30.0

1,266

0.164

0.1138

312

240

37

19.6

1.7

23.0

51

1.6

2.0

32.7

1,522

0.125

0.1107

362

300

61

22.0

1.8

25.6

46

2.0

2.1

36.7

1,941

0.100

0.1102

407

400

61

25.5

2.0

29.5

52

2.0

2.3

41.0

2,430

0.078

0.1074

466

500

61

28.2

2.2

32.6

57

2.0

2.4

44.3

2,835

0.061

0.1058

528

*Reactance is for trefoil configuration.


**Cable ampacity for direct burial installation.
Maximum conductor temperature: 90C
Ambient air temperature: 30C
Ground temperature: 20C
Depth of laying: 0.8m
Thermal resistivity of soil: 1.5Km/W
Screen bonded at both ends.
+Diagrams of cables are illustrative only and not necessarily to scale. PDP reserves the right to change or vary the construction of any of their products without notice. While every care has been taken in the preparation of this
data sheet, PDP accept no liability of any kind and are not responsible for the results of any actions taken on the basis of this information or resulting from errors or omissions. This technical data sheet is intended as a guide
only; any person using it must make reference to the appropriate local standards or authorities.

Executive office:
2297 2/F BCS Prime Bldg. Pasong
Tamo Ext. Makati City, Philippines
T. (632) 813-2529
F. (632) 893-4990

Manufacturing Plant:
Luisita Industrial Park
San Miguel, Tarlac City Philippines
T. (6345) 985-1088 to 91

Customer Approval
Name
Signature
Date

PDP
Prep GGM
Approval CCG
Date 11/04/15

You might also like