Gas-insulated switchgear ELK-04, 145 kV


Modular system with 3150 A, 40 kA

ABB is the pioneer in gas-insulated switchgear (GIS) technology with over 50 years of proven technology. With a wide
range of GIS products up to 1200 kV, ABB provides reliable
and eco-efficient solutions for transmission, distribution grids,
power plants and industries.
The ELK-04 is the ideal solution for reliable energy distribution up to a rated voltage of 145 kV, a rated normal current
up to 3150 A and a rated short-circuit current up to 40 kA.
Based on a few building blocks with standardized dimensions,
its space saving and modular design offers a small footprint
and easy operation at high performance ratings. All functional
modules are type tested according to international standards
(IEC/ANSI). The ELK-04 offers a high level of flexibility for
optimizing substation layouts while reducing operating and
maintenance costs.

The ELK-04, 145 kV provides:


Complete three phase encapsulation
Economic and compact layouts for ratings with 145 kV,
3150 A, 40 kA
Three- and single-pole operation
Resistance against earthquakes with high performance level
of 1g
Low environmental impact due to optimized design with
reduced SF6 gas
Smart Grid Enabled control and protection
Low life cycle and maintenance costs
Ideal solutions for hydro power plants and offshore wind
farms
Container solutions with complete bays
Reliable, well-proven technology based on five decades of
experience

ELK-04, 145 kV

Product-ID

Rated voltage

kV

145

Rated short-duration power-frequency withstand voltage

kV

275

Rated short-duration power-frequency withstand voltage across isolating distance

kV

315

Rated lightning impulse withstand voltage

kV

650

Rated lightning impulse withstand voltage across isolating distance

kV

750

Rated frequency

Hz

50

Rated normal current

Rated short-time withstand current

kA

Rated duration of short-circuit

Rated peak withstand current

kA

3150
40
3
104
Indoor / Outdoor

Rated filling pressure / minimum functional pressure (abs. at 20 C): Circuit-breaker

MPa

0.7 / 0.6

Rated filling pressure / minimum functional pressure (abs. at 20 C): Other components

MPa

0.6 / 0.52

Rated operating sequence

O-CO / CO-CO / O-CO-CO

The above data are not limiting values. Additional data on request. We reserve the right to alter data and technical details without notice.

4
6

Legend

2
1

1 Disconnector and earthing switch (busbar)


2 Circuit-breaker

3 Current transformer
4 Disconnector and earthing switch (feeder)
5 Voltage transformer
1

6 Make-proof earthing switch


7 Cable exit
8 Local control cubicle (LCC)

ABB AG
High Voltage Products
Brown-Boveri-Strasse 30
63457 Hanau-Grossauheim / Germany
Phone: +49 6181 5090
www.abb.com/highvoltage