Ring vn ni tn XT s hi li bn FLS v s thng bo li vi nh thu. Trc y FLS c hng dn
v ni thp ti xng nhng l dnh cho kt cu thp, chng ti gi li cho anh tham kho trc: Dear Sirs, Knh gi cc ngi,
Please find answer to question received 2015.12.10 at site regarding Dept.
421 - Fabrication - Extending of steel profiles (column) in workshop: Xin vui lng xem cu tr li cho cu hi nhn c ngy 10/12/2015 lin quan n hng mc 421 Ch to M rng cc hnh dng thp (ct) ti xng:
For steel structure fabricated in workshop in accordance with BS EN
1090-2:2008 the following shall be recommended: Vi kt cu thp c ch to ti xng theo tiu chun BS EN 1090-2:2008, kin ngh nh sau:
Welded splices joining profiles/materials shall be permitted under the
following conditions Mi ni hn ghp ni thp hnh/vt liu phi c theo cc iu kin sau:
1) One splice pr. element/member only.
Ch mt mi ni cho tng b phn/chi tit. 2) Full penetration butt welds. Hn kn su ton b cc mi hn ni u. 3) 100% visual and ultrasonic testing. 100% phi c kim tra bng mt thng v bng phng php siu m.
Splice joints must be clearly stated in fabricators QA documentation.
Cc mi ni chng phi c ch ra r rng trong ti liu QC ca nh ch to.
Please note that for steel fabrication according to BS EN 1090-2:2008 the
following shall be recommended: Vui lng lu rng vi vic gia cng thp theo tiu chun BS EN 1090-2:2008, kin ngh nh sau:
Classification according to BS EN 1090-2:2008 annex B:
Phn loi theo tiu chun BS EN 1090-2:2008 ph lc B:
Consequence Class : Cp quan trng
CC2 (CC1*)
Service category : Loi phc v
SC2
Production Category :
PC2
Loi sn xut
Execution Class :
EXC3 (EXC2*)
Cp thi cng
* For secondary structures, purlins and cladding only.