You are on page 1of 16

H azardous Area Lighting

IN TRODU CTION

Flam eproofBulkhead Lum inaire

Flam eproofAviation Obstruction Light

Flam eproofLum inaire For Fluorescent


Tubular Lam p

Flam eproofControlGear Box

Flam eproofN on-integralW ellglass


Lum inaire

Increased Safety N on IntegralW ellglass


Lum inaire

Flam eproofIntegralW ellglass Lum inaire

Increased Safety IntegralW ellglass Lum inaire

Flam e ProofN on-integralFlood Light

ControlGear Box for Increased Safety Lum inaire

HAZARDOUS A

H azardousArea Lighting
In the areas w here flam m able m aterials are m anufactured,produced,processed orstored,m ixing offlam m able gases w ith air
is likely to happen in the atm osphere.Ifdue to the electricalequipm entinstalled in such areas,ignition takes place due to a
spark orfire,itcan lead to a hazardous situation.Although the prim e requirem entis to avoid the occurrence ofsuch conditions
w here thisisnotpractical,specialm ethodsofsafeguarding electricalapparatusm ustbe em ployed.
Care should be taken to avoid flam m able orexplosive atm ospheres,inorderto have an ignition,both a flam m able atm osphere
and m eansofignition m ustexistsim ultaneously.

Types ofH azardous situations :


Depending on the presence offlam m able m aterialthe hazardous areas are classified in to H azardous Zones.

Typicalillustration ofZone 0,Zone 1,Zone 2 areas


w ith source ofignition

ZON E 2
ZON E 0
(SOU RCE)

ZON E 1

ZON E 0
TH E EXPLOSIVE ATM OSPH ERE IS CON TIN U OU SLY PRESEN T
A Zone in w hich an explosive m ixture is continuously present(in the gaseous phase)inside a receptacle ora
closed cham berconstitute Zone 'O

ZON E 1
TH E EXPLOSIVE ATM OSPH ERE IS OFTEN PRESEN T
A Zone in w hich an explosive m ixture ofGas,VapourorDustis likely to occurin norm aloperations.In these areas
flam eprooflum inairesand accessoriesare used.
Flam eproofEnclosure -is one w hich w illw ithstand w hen allthe covers and accessories are properly secured,an
internalexplosion ofthe flam m able gasorvapourthrough the jointgapsand flam e pathsprovided in the enclosure.
N ote:The term 'Flam eproof'issynonym ousw ith the term 'Explosion-proof'asused in U SA or'Explosion-Proof'type
'd'protection used in Germ any and otherContinentalcountries.

ZON E 2
TH E EXPLOSIVE ATM OSPH ERE IS ACCIDEN TALLY PRESEN T
A Zone in w hich an explosive m ixture is notlikely to occurin norm aloperations and ifitoccurs w illonly existfora
short tim e (Leaks or negligent use). In these areas, Increased Safety Lum inaires are used and are generally
provided w ith gaskets and speciallam p holders in case offittings.These equipm ents are m anufactured as perIS
8224/1976 and IS 6381/1972.

AREA LIGHTING

Itshould be noted thatfittings com plying w ith the requirem ents as specified in IS 8224/1976 are notsuitable for gases or
vapourhaving ignition tem perature below 200oC.The follow ing is the listofgases orvapours know n to have self/auto ignition
tem perature below 200oC.
1.
3.
5.
7.
9.
11.

Ethylnitrate
Carbon disulphide
Diethylether
Dibutylether
Dihexylether
EthylM ethylether

2.
4.
6.
8.
10.
12.

Isopropylnitrate
Acetaldehyde
Diproplylether
Diam ylether
Benxaldyhyde
Diethylperoxide

Tem perature Classes


zure atw hich a flam m able gas m ixture ignites.Flam m able vapours and gases can be
Ignition tem perature is the low esttem perat
classified into tem perature classes according to theirignition tem perature.Surface tem perature ofthe lum inaire is likely to be
higherthan am bienttem perature due to heatgenerated during fire orexplosion inside the enclosure.The m axim um surface
tem perature of the lum inaire m ust alw ays be low er than the ignition tem perature of the gas m ixture present in the air.
Lum inaire ofappropriate specified tem perature classshould be selected based on the ignition tem perature ofthe gas.

TemperatureClass

T1
T2
T3
T4
T5
T6

Maximum SurfaceTemperature
ofLuminaires(C)
450
300
200
135
100
85

Dustproof/Dust-tight
Lum inaires are m anufactured as per IS 4012 /IS 4013-1967 and are recom m ended to be installed in industries w here in
addition to the recognized explosives,m any otherdusts including practically allorganic and inorganic dust,(dustofm etals are
flam m able to som e extentdepending on the particle size),specific gravity ofdustetc.are present.
Dustshave been broadly classified into the follow ing groups.
Class1 Dustw hich ignite and propagate flam e readily,the source ofheatrequired forignition being sm all.
Class2 Dustw hich ignite readily w ith flam e butrequire a largersource ofignition.
Class3 Dustw hich do notignite.
Dust-tightlum inaires are recom m ended forlocations laden w ith Class 1 Dust.Forotherclass ofdust,dustprooflighting fittings
m ay be used.

HAZARDOUS AR

IngressProtection System forEnclosures(IP)


This system outlined in IS 2147 is designed to indicate the standard degree ofprotection:(a)from ingress ofsolids and (b)from
ingressofliquidsw hich enclosuresm ay exhibitand m ustnotbe confused w ith explosion protection techniques.
Forlum inairesthe follow ing IP num berscom m only apply :
Drip proof
Rain proof
Splash proof
Dustproof/Splashproof
Dustproof/Jetproof
Dust-tight/Jetproof

IP 22
IP 23
IP 34
IP 54
IP 55
IP 65

H igherthe num ericalofthe firstand second characteristic,the greaterdegree ofprotection the enclosure offers.E.g.Jetproof
IP 55 m eetsallthe lessonerousdegreessuch asIP 22,IP 23,IP 34 and IP 54.

Testing Authorities
Allour Flam eproofand Increased safety lum inaires are tested and Certified by CentralInstiture ofM ining and FuelResearch
(CIM FR),Dhanbad.

Standards
(a)Flam eproof Construction : IS:2148-2004 (IEC 60079-1/2001)
(b)Generaldesign,rating,perform ance & T-class: IS:13346-2004 (IEC 60079-0/2000)
(c ) W eatherproofconstruction IP-65 : IS:12063-1987 (IEC 60529/1989)

Table 3 ofIS 2148/1981


G roup ofEnclosuresSuitable forParticularFlam m able G asorVapour(C lauses1.4 and 3.1.2)
Group of
Enclosures
I

Gas or Vapour
M ethane (fire dam p)

II A

Am m onia,Industrialm athane*,Blastfurnace gas,Carbon m onoxide,Propane,Butane,Pentane,H exane,H eptane,


Iso-Octane,Decane,Benzene,Xylene,Cyclohexane,Acetone,Ethylm ethylKetone,M ethylacetate,Ethylacetate,
N -propylacetate,N -butylacetate,Am ylacetate,Chlorothylene,M ethanol,Ethanol,ISO-butanol,N -Butanol,Am ylalcohol,
Ethylnitrate.

II B

1,3-Butadine,Ethylene,Diethylether,Ethylene oxide,Tow n gas,Coke-oven gas.

II C

H ydrogen

*IndustrialM ethane includes m ethane m ixed w ith notm ore than 10% by volum e ofhydrogen.Tow n gas m ay contain notm ore
than 57% by volum e ofhydrogen and notm ore than 16% by volum e ofcarbon m onoxide,the rem ainderbeing a m ixture of
paraffin hydrocarbonsand inertgas.
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Note :
Due to ourcontinuous efforts in developing products,im provem ent-BajajElectricals Lim ited reserves the rightto m ake changes in the
design and data withoutany priornotice.

AREA LIGHTING

Flam eproofBulkhead Lum inaire

Flam eproofLum inaire


For FluorescentTubular Lam p

BJFB 150/200 BC/ES (LM 6)

BJFFTL 136/236,140/240,128/228

Lum inaire Body

Lum inaire Body

Epoxy finish CastAlum inium LM 6 housing.

CastAlum inium LM 6 housing w ith Epoxy finish.H eatresistantborosilicate


tubular glass held in tw o alum inium cups. Tw o cable entries of 3/4 BS
conduitare provided.

Toughened Type A flatglass.


Tw o cable entriesof3/4BS conduitare provided.

Lam p

Lam p holdersuitable forlam p type w illbe provided (2 pin BC /3 pin BC /E 27)


Lam p
Suitable for 1 0 0 W /1 5 0 W /2 0 0 W G LS, 8 0 W /1 2 5 W
70W SV/M H /150W M H (E27)160W M LL,26W CFL -Retrofit.

H P M V,

Single orTw in 36W /40 W FluorescentTubularlam p/28W T5 lam p.Special


variantfor18W /20 W FTL also available.
Tem perature Range
T6

Tem perature Range

IngressProtection

80W M V/70W SV/70W M H /100W GLS -T4

IP 65

125M V/150W M H /150W GLS/200W GLS /160W M LL T3

Suitable forZone 1 & 2 areas w here explosive gasses specified undergas


groupsIIA & IIB are present.

26W CFL -Retrofit-T6


Suitable for Zone 1 & 2 areas w here explosive gasses specified under gas
groups IIA & IIB are present.This is a non integrallum inaire suitable forindoor
application.Separate controlgearto be used in case ofH ID lam ps.

CIM FR Certificate N o
CIM FR/TC/SR/H 798 DTD 11.01.2008
N ote
ExternalStove Enam eled Reflectorcan be provided asan additionalfeature

CIM FR Certificate
CIM FR/TC/SR/H 909 DATED 08.02.2008

228

135

170

170
1590

235

235
380
235
267

BJFFTL-140/240

BJFFTL-140

125

BJFFTL-240

Flam eproofN on-integralW ellglass Lum inaire

Flam eproofN on-integralW ellglass Lum inaire

BJFW 80/125 M V N IBC/ES LM 6

BJFW 400 M V CA (N I)
BJFW 400 SV/M H CA (N I)/BJFW 250 SV (NI)

Lum inaire Body

Lum inaire Body

Cast Alum inium LM 6 housing w ith Epoxy finish. H eat resistant and
toughened glass enclosure type A w ith BC/E27 lam p holder Painted M S
w ire guard. Tw o cable entries of3/4 BS conduit are provided. Separate
flam eproofcontrolgearboxofsuitable rating to be used forH ID lam ps.

Cast Alum inium LM 6 housing w ith Epoxy finish. H eat resistant and
toughened glassenclosure type A.Painted M S w ire guard.Tw o cable entries
of3/4 BS conduitare provided.Available in castiron version for special
application areasalso.Thisisa non-integrallum inaire.Separate flam eproof
controlgearboxto be used asperthe lam p rating.

Lam p
Suitable for 80/125W M V, 70W SV/M H, 150W M H (E27), 200W GLS,
160W M LL,23W /26W RetrofitCFL lam p.

Lam p
250 W H PM V,400W H PM V,250W H PSV,400W H PSV,400W M H lam p.

Tem perature Range

Tem perature Range

150W M H (E27),200W GLS,160W M LL -T3


125W M V T4
80W M V/70W SV/70W M H T5
T6
23W /26W RetrofitCFL -

250W /400W H PM V -T3, 250W H PSV -T5,400W H PSV/M H -T4


Suitable foruse in Zone 1 & 2 areas w here explosive gasses specified under
gasgroupsIIA & IIB are present.
IngressProtection

Idealforuse in Zone 1 & 2 areasw here explosive gassesspecified undergas


groupsIIA & IIB are present.

IP 65
CM RICertificate N o

IngressProtection

CM RI/TC/P/H /382 DTD 18.08.2006

IP 65
CIM FR Certificate N o

100 100
A

530

CIM FR/TC/SR/H 1136 DATED 19.03.2008

402

335

247

A = 3 N os., 12.5 H O LE

Flam eproofIntegralW ellglass Lum inaire


For H PM V/H PSV and M etalH alide Lam p

Flam eproofIntegralW ellglass Lum inaire


ForHPM V/HPSV And M etalHalide Lam p

BJFW 80/125 M V ICA BC/ES


BJFW 70 SV/M H I

BJFW 250 M V ICA


BJFW 150 SV/M H I

Lum inaire Body

Lum inaire Body

Cast Alum inium LM 6 housing w ith Epoxy finish. H eat resistant and
toughened glassenclosure-type A.Painted M S w ire guard.Tw o cable entries
of3/4 BS conduitare provided.This is an integrallum inaire.H ID ballast
and accessoriesfitted inside the housing.

Cast Alum inium LM 6 housing w ith Epoxy finish. H eat resistant and
toughened glassenclosure type A.Painted M S w ire guard.Tw o cable entries
of3/4 BS conduitare provided.This is an integrallum inaire H ID Ballast&
accessoriesfitted inside the housing.

Lam p

Lam p

Suitable for80W /125 W H PM V,70W H PSV/M H lam p.

Suitable for150W H PSV/M H lam p,250 H PM V lam p.

Tem perature Range

Tem perature Range

T4

T4

Idealforuse in Zone 1& 2 areas w here explosive gasses specified undergas


groupsIIA & IIB are present.

Idealforuse in Zone 1& 2 areas w here explosive gasses specified undergas


groupsIIA & IIB are present.

IngressProtection

IngressProtection

IP 65

IP 65

CIM FR Certificate N o

CIM FR Certificate N o

CIM FR/TC/SR/H 840 DATED 24.01.2008

CM RI/TC/P/H 378 DATED 18.08.2006

N ote

530

Thislum inaire can also be used asnon integralfor250W M V/150SV/150 M H BJFW 250 W M V (N I),
BJFW 150 W SV (N I),BJFW 150 W M H (N I)

480

247
245

BJFW 250 M V I

Flam eproofN on-integralFlood Light

Flam eproofAviation Obstruction Light

BJFFL 250/400 N I

BJFAOL 01

Lum inaire Body

Lum inaire Body

Cast Alum inium LM 6 Epoxy finish lam p housing. H eat resistant and
toughened flatglass Type A.One Cable entry through 3/4BS conduit.This
is a non integrallum inaire and suitable flam eproofcontrolgearbox should
be separately used.

Cast alum inum LM 6 yellow epoxy pow der coated housing. H eat resistant
and toughened type A glass enclosure.Tw o cable entries of3/4BS conduit
are provided.
Idealforuse in zone 1 & 2 areas w here explosive gasses specified undergas
groupsIIA & IIB are present.

Idealforuse in zone 1 & 2 areas w here explosive gasses specified undergas


groupsIIA & IIB are present.

Lam p

Lam p

Suitable forN eon spirallam p 75VA

Suitable for250 H PM V/250W H PSV/400W H PSV/400W M H.

Tem perature Class

Tem perature Range

T6

250W M V -T5 ,400W SV/M H -T4,250W SV T6.

IngressProtection

IngressProtection

IP 65

IP 65

CM RICERT.N O

CM RICERTIFICATE N O

CM RI/TC/P/H 354 dt.10th Aug 2006.

CM RI/TC/P/H 387 DTD.21.08.2006

245

700

495

375

500

38

100 100

BJFFL 250/400 M V N I

BJFAO L-01

Flam eproofControlGearBox

Increased Safety N on-Integral


W ellglass Lum inaire

BJFC 80W /125W /250W M V CA


BJFC 70W /150W SV/M H
BJFC 400 M V/SV/M H

BJDP/DT/TE/ISW -200 LM 6 N I

H ousing

Lum inaire Body

Die-cast alum inium LM 6 housing. Com pletely w ired w ith control gear
accessories.Three cable entries of3/4 BS conduitare provided.Idealfor
use in ZON E 1 & 2 areas w here explosive gasses specified undergas groups
IIA & IIB are present.

CastAlum inium LM 6 housing w ith Epoxy finish.H eatresistantw ellglass


cover. Painted M S w ire guard. Tw o cable entries of 3/4 BS conduit are
provided. This is a dustproof,dusttight,totally enclosed,increased safety
non-integral lum inaire. Separate increased safety control gear box to be
used asperZone 2 the lam p rating.

Lam p

Lam p

Versions available for 80W /125W /250W H PM V lam p, 70W /150W


H PSV/M etal H alide lam p and 3 X 26W CFL. Also available for 400W
H PM V/400W H PSV/M H lam p.

Suitable for150/200W GLS,160W M LL ,80W /125W H PM V,70W H PSV


-Elliptical, 23 W RetrofitCFL.

Tem perature Range

IngressProtection

T6

IP 65

IngressProtection

Tem perature Class

IP65

Volts250 Max.

CIM FR Certificate N o
TemperatureClassification

CIM FR/TC/SR/H 800 DTD. 15/01/2008 for 80W /125W /250 H PM V,


70/150SV/M H
CIM FR/TC/SR/H 837 DTD.23/01/2008 for400W H PM V/H PSV/M H lam ps.
235

MLL

SV

CFL

150W

GLS
200W

80W

HPMV
125W

160W

70W

23W

T5

T5

T6

T5

T5

T6

T6

CM RICertification
CM RI/TC/P/H 1335 DTD 10.11.1998
Applicable standardsand certification

335
205

lS : 2147-1962 Specification forDegree ofprotection


lS : 8224-1976 Specification forElectric Lighting FittingsforDivn.2 areas
lS : 6381/1972 Specification of Electrical Apparatus w ith type of
protection 'e'
lS : 6381/1972 Specification ofconstruction ofElectrical Apparatus w ith
type ofprotection 'e'
210
lS : 13947 (part1)1993 forlP 65

111

238
320

Increased Safety N on-Integral


W ellglass Lum inaire

Increased Safety IntegralW ellglass Lum inaire

BJISW 80/125 M V N I/70 SV N I

BJISW 80/125 M V (I)


BJISW 70SV (I)

Lum inaire Body

Lum inaire Body

CastAlum inium LM 6 housing w ith Epoxy finish.H eatresistantw ellglass


cover,Idealforuse in Zone 2.Painted M S w ire guard.Tw o cable entries of
3/4 BS conduit are provided. This is a dustproof, dust tight, totally
enclosed, increased safety non-integral lum inaire. Separate increased
safetycontrolgearboxtobeused asperthelam p rating.

Cast Alum inium LM 6 housing w ith Epoxy finish. H eat resistant and
toughened glass cover-type A.Painted M S w ire guard.Tw o cable entries of
3/4BS conduitare provided.

Lam p

Ingressprotection:IP 65

Suitable for150/200W GLS,160W M LL ,80W /125W H PM V,70W H PSV


-Elliptical, 23 W Retrofitlam p.

Lam p
Suitable for 80/125W M V lam p, 70W H PSV lam p. H ID ballasts and
accessoriesw ired inside the housing.Itcan also be used for250W H PM V as
non integral lum inaire. Separate control gear box to be used for 250W
H PM V version -BJISW 250 M V N I.

IngressProtection
IP 65
CM RICertification

CM RICertification

CM RI/TC/P/H 1455 Dated 26.11.98 forBJISW


Applicable standardsand certification
lS : 2147-1962 Specification forDegree ofprotection
lS : 8224-1976 Specification forElectric Lighting FittingsforZone 2 areas
lS : 6381/1972 Specification of Electrical Apparatus w ith type of
protection 'e'
lS : 6381/1972 Specification ofconstruction ofElectrical Apparatus w ith
type ofprotection 'e'
lS : 13947 (part1)1993 forlP 65
Volts250 Max.

TemperatureClassification

Idealforuse in areasw here explosive orignitable gasesare present(Division


2 areas).

BLL

SV

CFL

150W

GLS
200W

80W

HPMV
125W

160W

70W

23W

T5

T5

T6

T5

T5

T6

T6

This lum inaire has been tested and certified by CM RI,Dhanbad vide their
letterRef.N o.
CM RI/TC/P/H 1260 DATED 14-10-1999
CM RI/TC/ADDEN /H 193 DATED 16-02-2000
CCE N o.R1(1)136/ALPIN E/418 dated 15-02-2000
Applicable standardsand certification
IS :2147-1962 Specification forDegree ofprotection
lS :8224/1976 Specification forElectric Lighting FittingsforDivn.2 areas
lS :6381/1972 Specification ofconstruction ofElectricalApparatus w ith
type ofprotection 'e'
lS :13947 (part1)1993 forIP 65.
225

210

390
320

ControlGear Box
for Increased Safety Lum inaire
BJISCG 80/125/250 M V
BJISCG 70/150 SV

H OU SIN G
Die-cast alum inium LM 6 housing. Com pletely w ired w ith control gear
accessories.Three cable entriesof3/4BS conduitare provided.
Idealforuse in Zone 1 & 2 areas w here explosive orignitable gas m ixtures
are presentfora shortperiod.
Lam p
Suitable for 80/125W H PM V, 70W H PSV, 150W H PSV, 250M V lam p.
Prew ired w ith open construction ballastand accessories suitable forlam p
rating.
IngressProtection
IP 65
CM RICertificate N o
CM RI /TC/P/SL/H 1454 DTD 26/11/1998 for 80W /125W H PM V, 70W
H PSV
CM RI/TC/P/H 1361 DTD 12.01.1999 for250W H PM V,150W H PSV

210

102 C/C

210

103

200 C/C
215

FLAM EPROOF LUM INAIRES PRODUCT RANGE DETAILS


SR.NO. CIM FR REVALIDATION
CERTIFICATE
NO.& DATE

CIM FR/TC/SR/H840
DTD.24.01.2008

CIM FR SUPPLIM ENTARY


CERTIFICATE TO
REVALIDATION
CERTIFICATE NO.& DATE
CIM FR/TC/S/693
DTD.19.11.2008

ITEM

BJFW -250
FLAM EPROOF/W P
W ELLGLASS
LUM INAIRES

CAT NOS.

LAM P RATING

TEM P.
RANGE

IP

ZONE

GAS
GROUP

T3

IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65

1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2

IIA & IIB


IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB

T5
T4
T5
T5
T3
T6
T6
T3
T3

IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65

1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2

IIA & IIB


IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB

1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2

IIA & IIB


IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB

BJFW
BJFW
BJFW
BJFW
BJFW
BJFW
BJFW
BJFW
BJFW
BJFW

-250 M V (NI)
-80 M V (I)
-125 M V (I)
-70 SV (I)
-70 M H (I)
-150 SV (NI)
-150 M H (NI)
-150 M H (E27)(I)
-3X26 CFL (I)
-300 GLS

250 W HPM V
80 W HPM V
125 W HPM V
70 W HPSV
70 W M H
150 W HPSV
150 W M H
150 W M H (E27)
3X26 W CFL
300 W GLS

-80 M V (NI)
-125 M V (NI)
- 70 SV (NI)
- 70 M H (NI)
-150 SV (E27)(NI)
-1X23 CFL (NI)
-3X26 CFL (NI)
-200 GLS (NI)
-160 M LL (NI)

80 W HPM V
125 W HPM V
70 W HPSV
70 W M H
150 W M H (E27)
23 W CFL
3X26 W CFL
200 W GLS
160 W M LL

T4

T4
T4
T3
T6

CIM FR/TC/SR/H1136
DTD.19.03.2008

CIM FR/TC/S/694
DTD.19.11.2008

BJFW -80/125
FLAM EPROOF/W P
NON-INTEGRAL
W ELLGLASS
LUM INAIRES

BJFW
BJFW
BJFW
BJFW
BJFW
BJFW
BJFW
BJFW
BJFW

CIM FR/TC/SR/H800
DTD.15.01.2008

CIM FR/TC/S/696
DTD.19.11.2008

BJFC -80/125/250
FLAM EPROOF/W P
CONTROL
GEAR BOX

BJFC -80 M V
BJFC -125 M V
BJFC -250 M V
BJFC -70 SV
BJFC -70 M H
BJFC -150 SV
BJFC -150 M H
BJFC -3X26 CFL

80 W HPM V
125 W HPM V
250 W HPM V
70 W HPSV
70 W M H
150 W HPSV
150 W M H
3X26 W CFL

T6
T6
T6
T6
T6
T6

IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65

CIM FR/TC/SR/H837
DTD.23.01.2008

CIM FR/TC/S/697
DTD.19.11.2008

BJFC -400 M V
FLAM EPRROF/W P
CONTROL
GEAR BOX

BJFC -400 M V
BJFC -400 SV
BJFC -400 M H

400 W HPM V
400 W HPSV
400 W M H

T6
T6
T6

IP 65
IP 65
IP 65

1& 2
1& 2
1& 2

IIA & IIB


IIA & IIB
IIA & IIB

CIM FR/TC/SR/H909
DTD.08.02.2008

CIM FR/TC/S/695
DTD.19.11.2008

BJFB -150/200
FLAM EPROOF
BULK HEAD
LUM INAIRE

BJFB -80 M V
BJFB -125 M V
BJFB -70 SV
BJFB -70 M H
BJFB -150 SV
BJFB -150 M H
BJFB -160 M LL
BJFB -1X26 CFL
BJFB -100 GLS
BJFB -150 GLS
BJFB -200 GLS

80 W HPM V
125 W HPM V
70 W HPSV
70 W M H
150 W HPSV
150 W M H
160 W M LL
26 W CFL
100 W GLS
150 W GLS
200 W GLS

T4
T3
T4
T4
T3
T3
T3
T6
T4
T3
T3

1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2

IIA & IIB


IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB

CIM FR/TC/SR/H798
DTD.11.01.2008

CIM FR/TC/S/H438
DTD.03.09.2008

BJFFTL -140
BJFFTL -240
BJFFTL -136
BJFFTL -236
BJFFTL -120
BJFFTL -220
BJFFTL -118
BJFFTL -218
BJFFTL -128
BJFFTL -228
BJFFTL -114
BJFFTL -214
BJFFTL -1X20 CFL

1X40 W
2X40 W
1X36 W
2X36 W
1X20 W
2X20 W
1X18 W
2X18 W
1X28 W
2X28 W
1X14 W
2X14 W
1X20 W

T6

T6

IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65

1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2
1& 2

IIA & IIB


IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB
IIA & IIB

BJFJB -100

IP 65

1& 2

IIA & IIB

CIM FR/TC/SR/H808
DTD.16.01.2008

BJFFTL -140
FLAM EPROOF/W P
FLUORESCENT
CIM FR/Am end/FLP/Oct./588 TUBE LIGHT
DTD.17.10.2008
LUM INAIRE

BJFJB -100
FLAM EPROOF/W P
JUNCTION BOX

FTL
FTL
FTL
FTL
FTL
FTL
FTL
FTL
(T5)
(T5)
(T5)
(T5)
CFL

T6
T6
T6

FLAM EPROOF LUM INAIRES PRODUCT RANGE DETAILS


SR.NO. CIM FR REVALIDATION
CERTIFICATE
NO.& DATE

CIM FR SUPPLIM ENTARY


CERTIFICATE TO
REVALIDATION
CERTIFICATE NO.& DATE

CM RI/TC/P/H382
DTD.18.08.2006
REVALIDATION NOT
REQUIRED AS TESTED
BYCM RIAS PER REVISED
BIS STANDARDS

CM RI/TC/P/H387
DTD.21.08.2006
REVALIDATION NOT
REQUIRED AS TESTED
BYCM RIAS PER REVISED
BIS STANDARDS

10

CM RI/TC/P/H378
DTD.18.08.2006
REVALIDATION NOT
REQUIRED AS TESTED
BYCM RIAS PER REVISED
BIS STANDARDS

11

CM RI/TC/P/H354
DTD.10.08.2006
REVALIDATION NOT
REQUIRED AS TESTED
BYCM RIAS PER REVISED
BIS STANDARDS

ITEM

CAT NOS.

LAM P RATING

TEM P.
RANGE

IP

ZONE

GAS
GROUP

BJFW -400 M V (NI)


FLP/W P
W ELLGLASS
LUM INAIRE

BJFW
BJFW
BJFW
BJFW

-400 M V (NI)
-400 SV (NI)
-400 M H (NI)
-250 SV (NI)

400 W
400 W
400 W
250 W

HPM V
HPSV
MH
HPSV

T3
T4
T4
T5

IP 65
IP 65
IP 65
IP 65

1& 2
1& 2
1& 2
1& 2

IIA & IIB


IIA & IIB
IIA & IIB
IIA & IIB

BJFFL-250/400 M V
NON-INTEGRAL
FLAM EPROOF/W P
FLOOD LIGHT
LUM INIARE

BJFFL -250 M V (NI)


BJFFL -250 SV (NI)
BJFFL -400 SV (NI)
BJFFL -400 M H (NI)

250 W
250 W
400 W
400 W

HPM V
HPSV
HPSV
MH

T5
T6
T4
T4

IP 65
IP 65
IP 65
IP 65

1& 2
1& 2
1& 2
1& 2

IIA & IIB


IIA & IIB
IIA & IIB
IIA & IIB

BJFW -250 M V (I)


FLAM EPROOF/W P
W ELLGLASS
LUM INIARE

BJFW -250 M V (I)


BJFW -150 SV (I)
BJFW -150 M H (I)

250 W HPM V
150 W HPSV
150 W M H

T4
T4
T4

IP 65
IP 65
IP 65

1& 2
1& 2
1& 2

IIA & IIB


IIA & IIB
IIA & IIB

BJFAOL -01
FLP/W P
AVIATION
OBSTRUCTION
LIGHT

BJFAOL -01

NEON SPIRAL
LAM P 75 VA

T6

IP 65

1& 2

IIA & IIB

INCREASED SAFETY LUM INAIRES


SR.

ITEM

NO.

CAT
NO.& DATE

CM RICERTIFICATE

CM RIADDENDUM S & SUPPLIM ENTARY

NOS.DATE

CERTIFICATES
NOS.DATE

ADDITIONS

BJDP/DT/TE/ISW -200 INCREASED SAFETY

BJDP/DT/TE/ISW -200

CM RI/TC/P/H1335

CM RI/TC/P/H1259

23 W CFL LAM P 70 W HPSV LAM P W ITH

W ELLGLASS FITTING SUITABLE FOR

INCREASED SAFETY

DTD.10.11.1998

DTD.14.10.1999

BUILT IN IGNITOR LAM P HOLDER 2 PIN /3 PIN /E 27

150 /200 W GLS LAM P 80 /125 W HPM V LAM P

NON INTEGRAL

160 W M LL LAM P IP 65

W ELLGLASS FITTING

BAKELITE /GFP /PORCELAIN CONNECTOR

BJISW -80/125 INCREASED SAFETY

BJISW -80/125

CM RI/TC/P/H1455

CM RI/TC/S/H1365

23 W CFL LAM P 70 W HPSV LAM P

W ELLGLASS FITTING SUITABLE FOR

INCREASED SAFETY

DTD.26.11.1998

DTD.15.11.1999

W ITH OR W ITHOUT BUILT IN ADOPTOR

150 /200 W GLS LAM P 80 /125 W HPM V LAM P

NON INTEGRAL

160 W M LL LAM P IP 65

W ELLGLASS FITTING

LAM P HOLDER 2 PIN/3 PIN /E 27

BJISW -80/125 (I)& BJISW -250 M V (NI)

BJISW -80/125 (I)

CM RI/TC/P/H1260

CM RI/TC/ADDEN/H193

INCREASED SAFETY W ELLGLASS FITTING

INCREASED SAFETY

DTD.14.10.1999

DTD.16.02.2000

SUITABLE FOR 80/125 W /250 W HPM V LAM P

INTEGRAL

70 W HPSV LAM P W ITH BUILT IN IGNITOR

W ELLGLASS FITTING

BJISW -80/125 (I)INTEGRAL & BJISW -250 M V (NI)


NON INTEGRAL INCREASED SAFETY
W ELLGLASS FITTING

70 W /150 W HPSV LAM P W ITHOUT IGNITOR IP 65


4

BJISCG -80/125 M V INCREASED SAFETY/W P

BJISCG -80/125

CM RI/TC/P/SL/H1454

CM RI/TC/S/H1310

CONTROL GEAR BOX IP 65

INCREASED SAFETY

DTD.26.11.1998

DTD.29.10.1999

CONTROL GEAR BOX


5

BJISCG -250 HPM V INCREASED SAFETY

BJISCG -250

CM RI/TC/P/H1361

CONTROL GEAR BOX SUITABLE FOR

INCREASED SAFETY

DTD.12.11.1999

250 W HPM V /150 W HPSV LAM P IP 65

CONTROL GEAR BOX

(A)70 W (B)CONNECTOR AS PORCELAIN /GFP /ELM EX

BRANCH

PHONE

FAX

E-m ail

AHM EDABAD
106,SakarIII,OffAshram Road
Navrangpura,Ahm edabad 380 014.

079-27543964,27543967,27540397

079-27543950

lum _am _ahm @ bajajelectricals.com

BANGALORE
BajajBhavan,No.16,Residency Road,
Bangalore 560 025.

080-22235486,22238984,22275505

080-22214878,22275505

lum _am _ban@ bajajelectricals.com

BHUBANESW AR
Kharavela Nagar,Janpath,Bhubaneswar751 001.

0674-2390697,2396980,2394052

0674-2390294

lum _am _bhu@ bajajelectricals.com

CHANDIGARH
SCO 52,Sector-26,M adhya M arg,
Chandigarh 160 026.

0172-4303211

0172-2792932

lum _am _chd@ bajajelectricals.com

CHENNAI
Navin's Presidium ,8th Floor,
A-Block,Old No.103-A,Nelson M anickam Road,
Am injikarai,Chennai600 029

044-42162200

044-42163300

lum _am _che@ bajajelectricals.com

COCHIN
CRL House,42/1107,Tata OilM ills Road,
Cochin 682 018.

0484-2391119,2396128,2392039

0484-2391744

lum _am _ccn@ bajajelectricals.com

DELHI
1/10,AsafAliRoad,New Delhi110 002

011-23236055,23233056,23235057

011-23230214

lum _am _del@ bajajelectricals.com

GUW AHATI
AgarwalHouse,Christian Basti,
G.S.Road,Guwahati787 005.

0361-2346497,2346498,2346499

0361-2346496

lum _am _guw@ bajajelectricals.com

HARYANA
1/10,AsafAliRoad,New Delhi110 002

011-43725500

011-23230214

lum _am _hyr@ bajajelectricals.com

HYDERABAD
H.No.6-3-1090/2,3rd Floor,VithalDas Cham bers,
Rajbhavan Road,Som ajiGuda,Hyderabad 500 082.

040-23442932,23442933,2344293

040-23302745

lum _am _hyd@ bajajelectricals.com

INDORE
Com m erce House,3 rd Floor,7 Race Course Road,
Indore 452 003,M P.

0731-2548909/10/18

0731-2548911

lum _am _ind@ bajajelectricals.com

JAIPUR
Raghukam alNiwas,M .I.Road,Jaipur302 001.

0141-2377364,2369541,2369542

0141-2374261

lum _am _jai@ bajajelectricals.com

KOLKATA
10,Ganesh Chandra Avenue,Kolkata 700 013.

033-22379270,22377657,22216638

033-22259111

lum _am _cal@ bajajelectricals.com

LUCKNOW
BajajBhavan,21/32 A,Tilak M arg,
Lucknow 226 001.

0522-2620595,2613549

0522-2626513

lum _am _luc@ bajajelectricals.com

M UM BAI
HarchandraiHouse,3rd Floor,81,Queens Road,
M arine Lines,M um bai400 002.

022-22089091

022-22089193

lum _am _m um @ bajajelectricals.com

NAGPUR
2nd Floor,SarafCourt,Opp.YashwantStadium ,
Dhantoli,Nagpur.

0712-2440318,2440319

0712-2420102

lum _am _war@ bajajelectricals.com

NOIDA
FlatNo.505-507,5th Floor,VikrantTower,
4,Rajendra Place,Pusa Road,New Delhi110 008.

011-25711961,25861963,25861964

011-25861962

lum _am _del2@ bajajelectricals.com

PATNA
KashiPlace,Dak Bunglow Road,Patna 800 001.

0612-2231427,2220155,2225911

0612-2231978,2231427

lum _am _pat@ bajajelectricals.com

PUNE
M aneck Hall,2,GeneralThim m ayya Road,
Pune 411 001.

020-26360801,26361321,26360703

020-26360698

lum _am _pun@ bajajelectricals.com

RAIPUR
BajajBhavan,G.E.Road,
NearM ahaveerGarden,Raipur492 001.

0771-2263986,2263976,2660166

0771-2263310

lum _am _rai@ bajajelectricals.com

LUM INAIRES HEAD OFFICE and R&D OFFICE


15/17,SantSavta m arg,Reay Road,
M um bai400 010.

022-2376 5000

Fax:022-2373 0504

HEAD OFFICE
51,M ahatm a GandhiRoad,M um bai400 001.

022-22043780,22851462,22875135

Fax:022-22828250

REGISTERED OFFICE

15/17,SantSavta M arg,Reay Road,M um bai-400 010.Phone :022-2376 5000,Fax :022-23730504,


E-m ail:lum inaires@ bajajelectricals.com ,W ebsite :w w w.bajajelectricals.com