You are on page 1of 3

Aproximate M-ulim and shear strength of beam

Width
Depth

300 mm
750 mm

Beam sizes
Width
Depth
fck
300 mm
Width
300 mm

750 mm
Depth
Tv
750 mm

fy
d-eff

415 N/mm2
675 mm

Mu-limit for the beam for fck in KN-m


15 N/mm2
283

20 N/mm2
378

25 N/mm2
472

30 N/mm2
566

35 N/mm2
661

Shear strength of the beam for Tv in KN


0.75 N/mm2
152

1 N/mm2
203

1.25 N/mm2 1.50 N/mm2 1.75 N/mm2


254
304
355

Beam Sizes in the toilet area of lower ground near lift core - see calculation files
Beam No
B1
B2
B3
B4
B5
B6
B7
B8

Beam size
400
750
200
600
200
600
500
700
400
750
300
750
300
750
400
750

loading
76.25KN/m+Pt. load
45 KN/m
89 KN/m
76.25KN/m+Pt. load
68KN/m +Pt.load
89 KN/m
76 KN/m+ 2Pt.loads
52KN/m+3 Pt.loads

Mu +ve
1128
36
57
1128
1262
464
468
1240

Shear
541
57
87
569
626
267
304
600

Tv
2.00
0.54
0.83
1.82
2.32
1.32
1.50
2.22

Mulim
754.52
228.22
228.22
808.59
754.52
565.89
565.89
754.52

Punching shear / two way shear in flat slab


Square column
Size of th panel
width
length
5.59 m
7.19 m

Size of col./ drop panel


width
Length
450 mm
450 mm

Shear area

39.86 m2

Total factored slab load

16.50 KN/m2

Total shear force

658 KN

Shear stress

1.81 N/mm2

Check

Change the thickness of slab or drop


or provide shear reinforcements

Depth of slab / drop


200 mm
Fck

Perimeter

25 N/mm2

2140 mm

You might also like