You are on page 1of 4

AXIAL FLOW FAN - direct driven

TDA - L
LONG CASED
Construction
Double flanged casing is produced in mild steel or galvanised
Steel, the impeller having manually adjustable pitch blades is
made of PPG, PAG or Aluminium.

Finish
Painting or galvanised after manufacture is normal finish
on all parts.

Operating Temperature
-20C to +55C

Motors
Totally enclosed Class F motor, to a min. IP54 protection
are fitted as standard. Standard motor up to 2.2kW are usually
supplied on DOL starting, motor 3.0kW and above are star/
delta starting.

Airflow Direction
Air flow from impeller to motor is fitted as standard. Air
flow from motor to impeller can be supplied upon request.

Option
Spark resistance construction in accordance with AMCA standard
99-0401-86-type C construction can be supplied upon request.

MODEL

Weight Max.Motor*
( kg ) FrameSize

D71

900

900

945

1000

630

18

12

10

D80

1000

1000 1050 1100

630

24

12

73

D160M

11

D90S

1120

1120 1185 1250

900

24

12

135

D225M

14

D90L

1250

1250 1315 1380

1000

24

12

170

D250M

10

18

D90L

1400

1400 1465 1530

1120

32

14

220

D250M

12

10

22

D112M

1600

1600 1663 1730

1250

32

14

275

D250M

500

12

10

24

D112M

1800

1800 1856 1930

1400

32

14

335

D280M

500

18

12

40

D112M

2000

2000 2073 2130

1400

32

14

380

D315M

560

18

12

49

D132M

2250

2250 2330 2400

1535

36

18

430

D315M

N x

All Dimension in mm.

MODEL

315

315

355

395

355

10

355

355

395

435

355

10

400

400

440

480

355

12

10

450

450

490

530

400

12

10

500

500

540

580

500

12

560

560

605

660

500

630

630

675

730

710

710

755

810

800

800

845

900

Weight Max.Motor*
( kg ) FrameSize
8

66

D160M

* Please consult KRUGER if motor frame size is beyond the catalogue range.
Note: Weight without motor and impeller.
The company is always improving and developing its products, therefore the company reserves the right of making changes to the illustrated products.
Certified dimension can be provided upon request.

LEA001.E2-03/05

Edition 4
Printed in Feb 2012

KRUGER VENTILATION INDUSTRIES PTE LTD


- No. 17 Tuas Avenue 10 - Singapore 639141
- Tel +65 68611577 - Fax+65 68613577
- www.krugerfan.com

A member of

QUICK SELECTION GUIDE 50 Hz


2 POLES - 2800 RPM
Hst (Pa)
1400
1200
1000
630

800
560

600

500
450

400

400
355

200

315

8
Air Flow (M3/S)

4 POLES - 1420 RPM


Hst (Pa)
320
280
240
630

200

560

160

500

120

450

80

400
355

40
315

0.5

1.5

2.5

3.5

4.5
5
Air Flow (M3/S)

4 POLES - 1420 RPM


Hst (Pa)
1200

1000
800

1250
1120

600
1000

400

900
800

200

710

12

15

18

21

24

27
30
Air Flow (M3/S)

*** Shaded portion is the recommended operating range based on the duct velocity consideration (friction loss of 1 Pa/m)

QUICK SELECTION GUIDE 50 Hz


6 POLES - 900 RPM
Hst (Pa)
240
210
180
150

900

120

800

90
60
30

710
630

6 POLES - 900
560 RPM
500

450

9
10
Air Flow (M3/S)

6 POLES - 900 RPM


Hst (Pa)
900
800
700
600
2000

500
400
300

1250
1120

200
100

1800

1600

1400

1000

20

10

30

40

50

60

70

80

90
Air Flow (M3/S)

8 POLES - 720 RPM


Hst (Pa)
500

4 POLES - 1750 RPM

450
400
350

2000

300

1800

250

1600
1400

200
1250

150

1120

100
50
0

900

1000

800

10

20

30

40

50

60

70
Air Flow (M3/S)

*** Shaded portion is the recommended operating range based on the duct velocity consideration (friction loss of 1 Pa/m)

QUICK SELECTION GUIDE 60Hz


4 POLES - 1750 RPM
Hst (Pa)
1200
1000
800
600

1000
900
800

400
560
630

500

200

710

450
400

10

12

14

16
18
Air Flow (M3/S)

6 POLES - 1150 RPM


Hst (Pa)
350
300
250
800

200
710

150

630
560

100
500

450

50

8
Air Flow (M3/S)

6 POLES - 1150 RPM


Hst (Pa)
1000

800
1600

600

1400
1250
1120

400
1000

200

900

10

20

30

40

50

60

*** Shaded portion is the recommended operating range based on the duct velocity consideration (friction loss of 1 Pa/m)

You might also like