You are on page 1of 2247

ZXG10 iBSC

Base Station Controller

Radio Parameter Reference


Version: V6.20.71

ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn

LEGAL INFORMATION
Copyright 2012 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited.

Additionally, the contents of this document are protected by

contractual confidentiality obligations.


All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided as is, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History
Revision No.

Revision Date

Revision Reason

R1.5

20120907

Add

parameters:

T23,

T24,

T3197,

RttiAccess,

MITPrepMRRecInt, MITMRRecInt, CellAlarmDelay.


Update parameters: Info_7, Inc8PskPwrThs, Inc8PskPwrHys,
PwrAdjustThreshold, PwrAdmitThrldPunish, PwrAdmitThreshold.
R1.4

20120731

Update to V6.20.713d
Add

parameters:

DualFreqNC2P,
ULRxLevThr,

DualFreqNC2Sup,
DualFreqNC2TAThr,

DLRxLevThr,

DualFreqNC2N,
DualCellPsChanThr,

ULRxQualThr,

DLRxQualThr,

TPingPang, NC2ResHys, NC2ResThr, NC2DistanceWindow,


PBGTHoBacktoSource,

OtherHoBacktoSource,

HoAccessReqLevOffset,

OtherHoAccessLevSel,

DualFreqOverLoadThs,

CSAllocSC,

PBGTHoBacktoSource,

IsDualFreqSup,

OtherHoBacktoSource,

HoAccessReqLevOffset, OtherHoAccessLevSel, SC1LoadThs1,


SC1LoadThs2, TsBlockAlarmSwitch, INFO1_0_8, RMST3109,
RMST3111.
Update parameters:

BCCHMaxPwrDec,

Subcell2MeasureBcch,
PathLossRatio,

HCS_Thr_0,

ENBID, HRDfragSupport,

SJ-20110531095035-017|2012-09-07 (R1.5)

CellShuttingDown,

FrToAmrHrHoLoadThSC2,
HCS_Thr_1,

CanBcchExch,

P0,

T3193,

HoControl_4,
INFO1_5_1,

ZTE Proprietary and Confidential

Revision No.

Revision Date

Revision Reason
INFO1_5_2, IPAInterHo, DownPowerBmp, PwDownLoadInd,
DivCombMode,

CSDHoIntraEnable,

CSDHoInterEnable,

HrToFrHoLoadThr,

AmrHrToFrHoLoadThr,

CSDHoOutEnable,

HrToFrHoLoadThrSC2, AmrHrToFrHoLoadThSC2, HoControl_1,


HoControl_2, Info_4_5, TdHoEnable.
R1.3

20120510

Update the chapter: About This Manual, Introduction to BSS


Radio Parameters, Method of Modifying Parameters in Batch,
Precautions on Parameter Adjustment.
Add new chapter Modify Parameters and new appendix Mutex
Right Management.

R1.2

20120319

Update to V6.20.712c
Add new MO: New Power Control Attribute and parameters which
are belong to this MO.
Add

parameters:

TSDRelPeriod,

HrToFrHoLoadThr,

TSDDeactDelay,

AmrHrToFrHoLoadThr,

HoUlQualThsForAmrFr,

HoUlQualAmrFrN,

HoUlQualAmrFrP,

HoUlQualThsForAmrHr,

HoUlQualAmrHrN, HoUlQualAmrHrP,

HoDlQualThsForAmrFr,

HoDlQualAmrFrN,

HoDlQualThsForAmrHr,

HoDlQualAmrHrN, HoDlQualAmrHrP,

HoDlQualAmrFrP,

HoUlLevThsForAmrFr,

HoUlLevAmrFrN,

HoUlLevAmrFrP,

HoUlLevThsForAmrHr,

HoUlLevAmrHrN,

HoUlLevAmrHrP,

HoDlLevThsForAmrFr,

HoDlLevAmrFrN,

HoDlLevAmrFrP,

HoDlLevThsForAmrHr,

HoDlLevAmrHrN,

HoDlLevAmrHrP,

HrToFrHoLoadThrSC2,
WindowEutran,

AmrHrToFrHoLoadThSC2,

FDDRptOffset6bit,

QSearchC,

FDDRptOffset3bit,

TDDRptOffset6bit,

TDDRptOffset3bit,

FDDRptOffset_PS,

TDDRptOffset_PS,

PwDownLoadInd,

DownPowerBmp,

HRTFRHOSupport2,

NccCfgPara,

DualFreqNetTchThs,

DivCombMode,

RQThreshold,
IsDualFreqRltCell,

PwDownHoPriInd, DualFreqHoSup, DualFreqHoN, DualFreqHoP,


DualFreqHoTAThs, DualFreqHoDLThs, SubCell2N, SubCell2P,
SubCellHoDLThs,

EUtranHighThreshQ,

EUtranLowThreshQ,

EUtranQQUALMIN,

RelEUtranStrategy,

RelEUtranPrio,

ChanSelForIPAHo,

SigTBFDlDelayTime,

SigTBFExtUlTime,

DataTBFDlDelayTime,
CSDHoIntraEnable,

DataTBFExtUlTime,
CSDHoInterEnable,

ISRSV,

CSDHoOutEnable,

DynSdCheckDelay.
Update

parameters:

NCellIndOfChlRel,

SubCell1N,
AmrThresholds,

SubCell1P,

TsRel,

AmrHysteresis,

AmrStartMode, RMSTT3109, RMSTT3111, TargetTrafficThsSC2,


Info_2_0, IsDualFreqRltCell, PSPwrChgStep0, PSPwrChgStep1,

Revision No.

Revision Date

Revision Reason
HoControl_1,

HoControl_2,

HoControl_4,

HoControl[1]_1,

HoControl[1]_2, HoControl[1]_4, HoControl[2]_1, HoControl[2]_2,


HoControl[2]_4, PcMinInterval, DLPcMinInterval, DLPwrRedStep.
R1.1

20110930

Update to V6.20.711c
Add

parameters:

EarlyDlTBFEstSupp,

IPAInterHo,

GetUtranClass,

SuppReducePd,

LmtThreshold_0,

LmtThreshold_1,

LmtThreshold_2,

LmtThreshold_3,

CsPagingPrefer,

IsDirectRetryCell,

CICAlarmSwitch,

BVCAlarmSwitch,

MOSmsIntercept,

TCobcchWaitMR,

MTSmsIntercept,
PbgtHoStartThsSC2,

FrToAmrHrHoLoadThSC2, FrToHrHoLoadThrSC2, UseSC1Load,


MrCountForRlt,

HoMarginPbgtSC2,

HoMarginRxQualSC2,

RxLevMinSC2,

HoMarginRxLevSC2,
TargetTrafficThsSC2,

Info_3, Info_6 Info_7, Info_3, Info_4, Info_5, Info_6, Info_7,


Info1_2, Info1_3.
Update

parameters:

HoMarginPbgt,

HoMarginRxQual,
HoMarginRxQual,
UtranCellPrio,

HoMarginPbgt,

HoMarginRxLev,
HoMarginRxLev,

ResourceAdjustThs,

ChlReqRejBmp,

PcMinInterval,

UtranCellPrio,
OldToNewctrl,

BtsId, AutoSToMEnable.
R1.0

20110730

First Edition (V6.20.71)

Serial Number: SJ-20110531095035-017


Publishing Date: 2012-09-07 (R1.5)

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Contents
About This Manual ......................................................................................... I
Chapter 1 Overview .................................................................................... 1-1
1.1 Introduction to BSS Radio Parameters................................................................. 1-1
1.2 Modify Parameters ............................................................................................. 1-2
1.3 Method of Modifying Parameters in Batch ............................................................ 1-4
1.4 The Format to Explain Parameters ...................................................................... 1-9
1.5 Precautions on Parameter Adjustment................................................................1-11

Chapter 2 BSC Function Parameters........................................................ 2-1


2.1 Radio Basic Property.......................................................................................... 2-1
2.1.1 DCS1800/PCS1900 support (FuncExt) ...................................................... 2-1
2.1.2 Load indication allowed (LoadInd) ............................................................. 2-2
2.1.3 Send confusion message allowed (ConfusionMsg) ..................................... 2-3
2.1.4 Inter-cell handover allowed (InHoEnable)................................................... 2-4
2.1.5 Send assignment failure allowed in outer direct retry procedure
(ExDRSendAssFail) ................................................................................ 2-6
2.1.6 Load indication Valid Time (LoadValidTime) ............................................... 2-7
2.1.7 Load Indication Period (LoadIndPrd).......................................................... 2-8
2.1.8 Congestion Threshold for Send Load Indication (LoadIndThs)..................... 2-9
2.1.9 Forbid Handover According to Resource Threshold of Load Indication
(LoadForbidHo) .................................................................................... 2-10
2.1.10 Resource Threshold of Load Indication for Forbid Handover
(LoadThsForbidHo) ................................................................................2-11
2.1.11 Support Precise Paging (PrecisePagSupport)......................................... 2-12
2.1.12 Use HPC for Precise Paging (PrecisepagUseHpc).................................. 2-13
2.1.13 Adopt Precise Paging for repaging of Circuit Switched Service
(CsRepagPrecise)................................................................................. 2-14
2.1.14 Adopt Precise Paging for repaging of Packet Switched Service
(PsRepagPrecise)................................................................................. 2-15
2.1.15 Allow Exceed area Precise Paging for Circuit Switched Service
(CsOutAreaPag) ................................................................................... 2-16
2.1.16 Allow Exceed area Precise Paging for Packet Switched Service
(PsOutAreaPag) ................................................................................... 2-17
2.1.17 Paging Repeat Time for Circuit Switched Service
(CsPagingRepeatTime) ......................................................................... 2-18

I
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

2.1.18 Paging Repeat Time for Packet Switched Service


(PsPagingRepeatTime) ......................................................................... 2-19
2.1.19 Automatic Resource Indication Threshold (ResourceIndThs)................... 2-20
2.1.20 BSC maximum reset number (BscMaxResetNum).................................. 2-22
2.1.21 MR report support (MrRptEnable).......................................................... 2-23
2.1.22 HBTS scan site number (HBTSScanSiteNum)........................................ 2-24
2.1.23 Range of Barang .................................................................................. 2-25
2.2 Functional Switch ............................................................................................. 2-26
2.2.1 RIM support (RIMSupport) ...................................................................... 2-26
2.2.2 RIM retry times (RIMRetryTimes) ............................................................ 2-27
2.2.3 Different reselection parameter in idle and transfer status support
(PSReselParam2) ................................................................................. 2-28
2.2.4 Handover synchronization indication support (Info_0_16).......................... 2-29
2.2.5 Switch of TRAU frame synchronized monitor (Info_4_5) ........................... 2-30
2.2.6 PS handover support (PSHoSupp) .......................................................... 2-31
2.2.7 Enable PS Handover Indications in Inter-BSS handover
(EnablePSHoIndi) ................................................................................. 2-32
2.2.8 Request SI/PSI (EnableRequestPSI) ....................................................... 2-33
2.2.9 Support EMLPP (SupportEMLPP) ........................................................... 2-34
2.2.10 DFCA support (DFCASupport) .............................................................. 2-35
2.2.11 Support resource optimizing by service (SuppResOpByService).............. 2-36
2.2.12 Identify of special service (SpecServiceIdentify) ..................................... 2-36
2.2.13 DTM Enhance Capability (DTMEnhanceCapa) ....................................... 2-37
2.2.14 E-UTRAN CCN support (EUtranCCN).................................................... 2-38
2.2.15 Duration of judging from concurrent to special service
(ConcurrentJudge0) .............................................................................. 2-39
2.2.16 Number of llc judging from concurrent to special service
(ConcurrentJudge1) .............................................................................. 2-40
2.2.17 Duration of judging from special to non-special service
(ConcurrentJudge2) .............................................................................. 2-41
2.2.18 Number of llc judging from special to non-special service
(ConcurrentJudge3) .............................................................................. 2-42
2.2.19 If get Utran classmrak information from UE (GetUtranClass) ................... 2-43
2.3 Other Parameters............................................................................................. 2-45
2.3.1 Supervision Timer of LCS (LcsSuperVision) ............................................. 2-45
2.3.2 Radio Timer of LCS (LcsRadio) ............................................................... 2-46
2.3.3 LCS wait intra BSS handover timer (LcsWaitInTraHO) .............................. 2-47
2.3.4 Monitor physical context request (RmsT9108) .......................................... 2-48
2.3.5 Timer for waiting message from A-interface (TWaitMsg) ........................... 2-48
II
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

2.3.6 Timer for RANCSEST waiting (TWaitRancsEst)........................................ 2-49


2.3.7 Timer for RANCSCLECOM waiting (TWaitRancsCleCom)......................... 2-51
2.3.8 Timer for CCM waiting (CcmWaitTimer) ................................................... 2-52
2.3.9 Get static parameter timer (GetStaticParamTimer).................................... 2-53
2.3.10 Starting time for oriented retry (RmsT10) ............................................... 2-54
2.3.11 TFO Enable (TFOControl_0) ................................................................. 2-55
2.3.12 External cell load notify (Info_0_0) ......................................................... 2-56
2.3.13 Neighbor cell load valid duration (Info_0_1)............................................ 2-57
2.3.14 LMU build request deal or not (Info_1_0) ............................................... 2-58
2.3.15 MBMS request deal or not (Info_1_1) .................................................... 2-59
2.3.16 Channel request reserved field deal or not (Info_1_2) ............................. 2-60
2.3.17 MS power hold in handover option (Info_0_9)......................................... 2-60
2.3.18 Signal level threshold of target cell (Info_0_10)....................................... 2-62
2.3.19 Iur-G interface support (IurgSupport) ..................................................... 2-63
2.3.20 Overload threshold of non real-time load (NRTThs_0)............................. 2-64
2.3.21 High threshold of non real-time load (NRTThs_1) ................................... 2-65
2.3.22 Low threshold of non real-time load (NRTThs_2) .................................... 2-66
2.3.23 On demand mode switch of information exchange
(IurgSwitchGroup_0) ............................................................................. 2-67
2.3.24 On modification mode switch of information exchange
(IurgSwitchGroup_1) ............................................................................. 2-68
2.3.25 On demand mode switch of common measurement
(IurgSwitchGroup_2) ............................................................................. 2-69
2.3.26 Periodic mode switch of common measurement (IurgSwitchGroup_3) ..... 2-70
2.3.27 Immediate assignment repeat (ImmAssRep) .......................................... 2-71
2.3.28 Immediate assignment priority (ImmAssPrio).......................................... 2-72
2.3.29 Paging repeat number (PagRep) ........................................................... 2-73
2.3.30 Timer of waiting for IPGB changing over (TIPGBChgWait) ...................... 2-74
2.3.31 restricted time after continuous IPGB changing over
(TIPGBConChglmt) ............................................................................... 2-75
2.3.32 Info_3 .................................................................................................. 2-76
2.3.33 Info_6 .................................................................................................. 2-77
2.3.34 Threshold of UPUDSP Dynamic Adjustment (Info_7) .............................. 2-77
2.4 Channel Allocation Control Parameters.............................................................. 2-78
2.4.1 Dynamic HR support indication (DynaHREnable) ..................................... 2-78
2.4.2 HR channel fragment repackaging support (HRDfragSupport)................... 2-79
2.4.3 User priority for EMLPP (PriThreshold) .................................................... 2-81
2.4.4 Preferred speech version (half) (PreferSpeechVer H) ............................... 2-82
III
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

2.4.5 Preferred speech version (full) (PreferSpeechVer F) ................................. 2-83


2.4.6 Reserved channel first (RsvChanFirst)..................................................... 2-84
2.4.7 EMLPP channel reserved rate (EMLPPThs)............................................. 2-85
2.4.8 TrxPSBusyThs (TrxPSBusyThs).............................................................. 2-86
2.4.9 Resource pool for PS rate (PsAbisThs).................................................... 2-88
2.4.10 Extended uplink dynamic allocation support (ExUpDynSupport) .............. 2-89
2.5 Timer 1 ............................................................................................................ 2-90
2.5.1 Blocking/Unblocking period (T1) .............................................................. 2-90
2.5.2 Global resetting period (T4)..................................................................... 2-92
2.5.3 Protective period for global resetting (T13) ............................................... 2-93
2.5.4 Circuit resetting period on BSS side (T19)................................................ 2-94
2.5.5 Circuit group blocking/unblocking period (T20) ......................................... 2-95
2.5.6 RLSD message receive protection timer (T9101)...................................... 2-96
2.5.7 Channel activation protection timer (RmsT9103) ...................................... 2-97
2.5.8 MSC clear command protection timer (T9104).......................................... 2-98
2.5.9 SCCP connection protection timer (T9105) .............................................. 2-99
2.5.10 Protective time waiting for access (RmsT1) ...........................................2-100
2.5.11 Protection time for applying to channel (RmsT2) ....................................2-102
2.5.12 Protection time for link establishment response (RmsT3) .......................2-103
2.5.13 Protective time that P0 confirms the message HO/ASS COM
(RmsT4) ..............................................................................................2-104
2.5.14 Encryption mode modification time (RmsT5) .........................................2-105
2.5.15 SAPI3 link establishment time (RmsT6) ................................................2-106
2.5.16 External handover protective time (RmsT8)...........................................2-107
2.5.17 Protective time for No.7 signal instantaneous disconnection (T3)............2-108
2.5.18 Protective time that PO responses external handover completion
message (RmsT7) ...............................................................................2-109
2.5.19 HBTS scan begin time (HBTSScanBT) ................................................. 2-110
2.5.20 HBTS scan cycle (HBTSScanCyc)........................................................ 2-111
2.5.21 IP ABIS Pool Band Width Push Down Protection (TBWPushDown) ........ 2-112
2.5.22 IP ABIS Pool Band Width Restore (TBWRestore) .................................. 2-113
2.5.23 Time of waiting an internal HO command (TWaitInternalHoCmd) ............ 2-114
2.5.24 Wait response of bts or btsgroup establish localswitch link
(TWaitLocalSwitch) .............................................................................. 2-116
2.5.25 Wait response of localswitch release link (TWaitLsReleaseAck).............. 2-117
2.5.26 Wait response of localswitch connect (TWaitLSBscConn) ...................... 2-118
2.5.27 Wait request of local switch release link (TWaitLSReleaseReq) .............. 2-119
2.6 Timer 2 ...........................................................................................................2-120
IV
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

2.6.1 Protective time for RF channel release (RmsT9)......................................2-120


2.6.2 Queue period of assignment (RmsT11)...................................................2-121
2.6.3 Acknowledgment interval for periodic status (RmsT12) ............................2-122
2.6.4 Mode modification process time (RmsT13)..............................................2-123
2.6.5 Protective time of UM assignment completion (RmsT14)..........................2-125
2.6.6 Waiting time for oriented retry (RmsT16).................................................2-126
2.6.7 Queue period for handover (RmsTqho)...................................................2-127
2.6.8 First overload period of flow traffic control (mT11)....................................2-128
2.6.9 Second overload period of flow traffic control (mT12)...............................2-129
2.6.10 Time of micro-micro handover delay (Tmicro) ........................................2-131
2.6.11 BSIC decoding period (Tbsic) ...............................................................2-132
2.6.12 Handover protecting timer to WCDMA/FDD (RmsT3121) .......................2-133
2.6.13 Immediate assignment period (RmsT3101) ...........................................2-134
2.6.14 Handover period of source cell (RmsT3103)..........................................2-135
2.6.15 Assignment period (RmsT3107) ...........................................................2-137
2.6.16 TCH Channel release period (RmsT3109).............................................2-138
2.6.17 TCH Channel deactivation delay (RmsT3111)........................................2-139
2.6.18 Continue timer for mode modify (TModeModifyConn) ............................2-140
2.6.19 Handover protecting time to UTRAN (mT7) ...........................................2-141
2.6.20 Time to wait A handover request (TWaitAHoReq) ..................................2-142
2.6.21 Time of destination instance waiting for available resources when forced
disconnection (RmsT15(TForceOccupy))...............................................2-143
2.6.22 Protecting time of FUC response to system message broadcast
(BcProtect) ..........................................................................................2-144
2.6.23 HO performed ack timer (TwaitHoPFMAck) ...........................................2-146
2.6.24 Timer of TRAU frame Synchronization (TuTrauSyn)...............................2-147
2.6.25 Round trip delay (RtdDefault) ...............................................................2-148
2.6.26 Timer to wait a relocation commit MSG from RNC
(TWaitRncRelocComm)........................................................................2-149
2.6.27 Subcell PingPong handover timer (TSCPingPang).................................2-150
2.6.28 Confirm BIPB fault time (TConfBIPBFault) ............................................2-152
2.6.29 Confirm BIPB DSP fault time (TConfBIPBDSPFault)..............................2-153
2.6.30 Confirm LAPD fault time (TConfLapdFault) ...........................................2-153
2.6.31 Confirm LAPD CPU fault time (TConfLapdCpuFault) .............................2-154
2.6.32 Confirm Sunit normal time (TConfSunitNor)...........................................2-155
2.6.33 Paging Interval (PagWaitTime) .............................................................2-156
2.6.34 Time of Cobcch Wait for MR Report (TCobcchWaitMR)..........................2-157
2.6.35 SDCCH Channel release period (TSDRelPeriod)...................................2-158
V
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

2.6.36 SDCCH Channel deactivation delay (TSDDeactDelay) ..........................2-159


2.7 GPRS Maximum Retrying Times ......................................................................2-160
2.7.1 Max times of BVC block retry (BVCBlkMax) ............................................2-160
2.7.2 Max times of BVC unblock retry (BVCUblkMax) ......................................2-162
2.7.3 MAX times of BVC reset retry (BVCRestMax) .........................................2-163
2.7.4 Max times of NS block retry (NSBlkMax).................................................2-164
2.7.5 Max times of NS unblock retry (NSUnblkMax) .........................................2-165
2.7.6 Max times of NS alive retry (NSAliveMax) ...............................................2-166
2.7.7 Max times of suspend retry (SuspendMax)..............................................2-167
2.7.8 Max times of resume retry (ResumeMax)................................................2-169
2.7.9 Max times of radio access capabilities update retry (UpdateMax) .............2-170
2.7.10 Max times of PFC create retry (DownLoadBssPFCMax) ........................2-171
2.7.11 Max times of PFC modify retry (ModifyBssPFCMax) ..............................2-173
2.7.12 Max of sending PS handover required (PSHoReqMaxNum) ...................2-174
2.8 GPRS Timer ...................................................................................................2-175
2.8.1 BVC block/unblock retry time (BssgpT1) .................................................2-175
2.8.2 BVC reset retry time (BssgpT2)..............................................................2-176
2.8.3 Suspend retry time (BssgpT3) ................................................................2-177
2.8.4 Resume retry time (BssgpT4).................................................................2-179
2.8.5 Access capability update retry time (BssgpT5) ........................................2-180
2.8.6 PFC creating retry time (BssgpT6)..........................................................2-182
2.8.7 PFC modifying retry time (BssgpT8) .......................................................2-183
2.8.8 RIR Timer (TRIR) ..................................................................................2-184
2.8.9 RI Timer (TRI) .......................................................................................2-185
2.8.10 RIAE Timer (TRIAE) ............................................................................2-186
2.8.11 BVC flow control period (CellFcPer) ......................................................2-187
2.8.12 MS flow control period (MsFcPer).........................................................2-189
2.8.13 Timer that monitors block/unblock procedure (NS_T1) ...........................2-190
2.8.14 Timer that monitors reset procedure (NS_T2) ........................................2-191
2.8.15 NC-cycle of NS-VC test process (NS_T3) .............................................2-192
2.8.16 Timer that monitors alive process of NSVC (NS_T4) ..............................2-193
2.8.17 Max attempt period of reset (NS_T5) ....................................................2-194
2.8.18 TFI and USF release timer (T3169) ......................................................2-195
2.8.19 TBF release timer (T3191) ...................................................................2-196
2.8.20 TBF release time of downlink transmission (T3193) ...............................2-198
2.8.21 TBF protect time when radio link failure (T3195) ....................................2-199
2.8.22 PS channel delay release timer (PSRelDelay) .......................................2-201

VI
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

2.8.23 Guards the PS handover required procedure (T12PsHo) .......................2-202


2.8.24 Guard resource release after sending PS HO command
(TwaitRelInPSHo) ................................................................................2-203
2.8.25 Downlink Delay time in signal TBF Mode (SigTBFDlDelayTime) .............2-204
2.8.26 Extendable uplink TBF time in signal TBF Mode (SigTBFExtUlTime) ......2-205
2.8.27 Synchronization timer that ensures source BSS receives both PS and
CS responses (T23) .............................................................................2-206
2.8.28 Synchronization timer that ensures target BSS receives both PS and
CS requests (T24)................................................................................2-206
2.8.29 T3197 (T3197) ....................................................................................2-206
2.9 AMR Half Method Parameters..........................................................................2-206
2.9.1 AMR Half Active Codec Set (AmrHalfAcs)...............................................2-206
2.9.2 Thresholds of AMR (AmrThresholds) ......................................................2-207
2.9.3 Hysteresis of AMR (AmrHysteresis)........................................................2-209
2.9.4 Initial codec mode (IsAmrlCM) ...............................................................2-210
2.9.5 Start mode (AmrStartMode) ................................................................... 2-211
2.9.6 Enable noise control (IsAmrNscb) ..........................................................2-213
2.10 AMR Full Method Parameters ........................................................................2-214
2.10.1 AMR full Active Codec Set (AmrFullAcs) ...............................................2-214
2.10.2 Thresholds of AMR (AmrThresholds) ....................................................2-215
2.10.3 Hysteresis of AMR (AmrHysteresis) ......................................................2-217
2.10.4 Initial codec mode (IsAmrICM) .............................................................2-218
2.10.5 Start mode (AmrStartMode) .................................................................2-219
2.10.6 Enable noise control (IsAmrNscb).........................................................2-221
2.11 GPRS Other Parameters 1 .............................................................................2-222
2.11.1 Cn (Cn) ...............................................................................................2-222
2.11.2 Nn (Nn) ...............................................................................................2-223
2.11.3 Xn (Xn) ...............................................................................................2-225
2.11.4 Max allowed number of continous losses of uplink data blocks
(N3101)...............................................................................................2-226
2.11.5 Times of packet uplink ACK/NACK retries (N3103) ................................2-228
2.11.6 Max allowed number of continous losses of uplink RLC/MAC control
message (N3105) ................................................................................2-229
2.12 GPRS Other Parameters 2.............................................................................2-231
2.12.1 NACC support (NACCSupport).............................................................2-231
2.12.2 Net operation mode (NMO) ..................................................................2-232
2.12.3 Page coordination support (PagCoordination) .......................................2-234
2.12.4 Satellite transmission at GB interface indication (IsStatelliteGB) .............2-235

VII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

2.12.5 Extended RLC send window allowed (IsWindowExpend) .......................2-236


2.12.6 TBF establish support (TBF_EST) ........................................................2-237
2.12.7 Signal extended uplink TBF support (SIGNAL_EUTBF) .........................2-238
2.12.8 Highest coding scheme of signal TBF (SigTBFMaxCode).......................2-239
2.12.9 Optimized POC service support (PocSupport) .......................................2-240
2.12.10 Highest coding scheme of POC service in GPRS (PocAttSelt_0) ..........2-241
2.12.11 Highest coding scheme of POC service in EGPRS (PocAttSelt_1) ........2-242
2.12.12 Max users of POC service on shared PS channel0
(PSCAPATHS_UL)...............................................................................2-243
2.12.13 Max users of POC service on shared PS channel1
(PSCAPATHS_DL)...............................................................................2-244
2.12.14 Service UTRAN CCO support (PSUTRANCCOSupp) ..........................2-245
2.12.15 LLC Transfer Support (LLCTranSupport_0~LLCTranSupport_15) .........2-246
2.12.16 LLC Pre-Transfer on NACC (Info_1_10)..............................................2-248
2.12.17 PDU buffer time (Info_1_16)...............................................................2-248
2.12.18 Choose PS route by NSVC (PSRouteByNSVC)...................................2-250
2.12.19 Enable PS Uplink Power Control In Establishment Phase
(PSUlPwrCtlInEsta)..............................................................................2-251
2.13 BVC Flow Control Parameters........................................................................2-252
2.13.1 BVC flow control support (BVCFlowCtrl) ...............................................2-252
2.13.2 MS flow control support (MSFlowCtrl) ...................................................2-253
2.13.3 Flow control mode (FlowCtrlMode) .......................................................2-254
2.13.4 Parameter of Flow control mode 1 (FlowCtrlMode1Para) .......................2-255
2.13.5 Parameter of Flow control mode 2 (FlowCtrlMode2Para) .......................2-256
2.13.6 BVC flow control R MIN value (BVCFlowCtrlRMin) ................................2-258
2.13.7 MS flow control R MIN value (MSFlowCtrlRMin) ....................................2-259
2.13.8 Support of PFC flow control procedures (PFCFlowCtrl) ..........................2-260
2.13.9 Coefficient of BVC bucket size (Info_2_0) .............................................2-261
2.13.10 Coefficient of MS bucket (Info_2_16) ..................................................2-262
2.13.11 CBL in BVC/MS flow control (Info_1_9) ...............................................2-263
2.14 FUC Flow Control Map Parameters ................................................................2-264
2.14.1 Flow control reason (ChlReqRejBmp) ...................................................2-264
2.14.2 Emergency Call...................................................................................2-265
2.14.3 Call Rebuilt .........................................................................................2-266
2.14.4 Call Response.....................................................................................2-267
2.14.5 Calling ................................................................................................2-268
2.14.6 Location Update ..................................................................................2-269
2.14.7 GPRS Access .....................................................................................2-270
VIII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

2.14.8 Restore...............................................................................................2-272
2.14.9 Flow Control Map Slim Adjust...............................................................2-273
2.15 EDGE Parameters.........................................................................................2-274
2.15.1 PFC support (PFCSupport) ..................................................................2-274
2.15.2 R99 Ind (R99Ind).................................................................................2-275
2.15.3 Support of enhanced radio status procedures (EnRadioStu)...................2-276
2.15.4 RS (RS) ..............................................................................................2-277
2.15.5 RR (RR) .............................................................................................2-279
2.15.6 RA (RA) ..............................................................................................2-280
2.15.7 RM (RM).............................................................................................2-281
2.15.8 RB (RB) ..............................................................................................2-282
2.15.9 RG (RG) .............................................................................................2-283
2.15.10 RE (RE) ............................................................................................2-285
2.15.11 ABIS resource dynamic manage (Info_1_8).........................................2-286
2.15.12 FANR in uplink TBF support (Info_4_0) ...............................................2-287
2.15.13 FANR in downlink TBF support (Info_4_1)...........................................2-288
2.15.14 DLDC support (Info_4_2) ...................................................................2-289
2.15.15 RTTI support (Info_4_3) .....................................................................2-290
2.15.16 EGPRS2-A support (Info_4_4) ...........................................................2-291
2.15.17 EGPRS prior to GPRS Support (Info_4_6) ..........................................2-292
2.15.18 Allocating weights of EGPRS (Info_4_7) .............................................2-293
2.16 eMLPP Set Parameters .................................................................................2-295
2.16.1 Strategy for preemption when assign (AssPreemptstrategy)...................2-295
2.16.2 Strategy for preemption when handover (HoPreemptstrategy) ................2-296
2.16.3 Max forced handover times when assign (AssForcedHoTry)...................2-297
2.16.4 Max forced handover times when handover (HoForcedHoTry)................2-298
2.16.5 Max forced release times when assign (AssForcedRelTry).....................2-299
2.16.6 Max forced release times when handover (HoForcedRelTry) ..................2-300
2.16.7 Preemption duration when assign (AssPreempTimer) ............................2-301
2.16.8 Preemption duration when handover (HoPreempTimer) .........................2-302
2.16.9 Timer for start forced release when assign (AssForceRelTimer)..............2-303
2.16.10 Timer for start forced release when handover (HoForceRelTimer).........2-305
2.16.11 Interval for search forced handover target when assign
(AssForceHoInterval) ...........................................................................2-306
2.16.12 Interval for search forced handover target when handover
(HoForceHoInterval).............................................................................2-307
2.16.13 Interval for search forced release target when assign
(AssForceRelInterval)...........................................................................2-308
IX
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

2.16.14 Interval for search forced release target when handover


(HoForceRelInterval) ............................................................................2-309
2.16.15 Queue timer for assign (RmsT11) .......................................................2-310
2.16.16 Queue timer for handover (RmsTqho) ................................................. 2-311
2.16.17 Queue indicate when assign (QueueIndAss) .......................................2-312
2.16.18 Queue allowed when handover (QueueIndHo) ....................................2-313
2.16.19 Forced release indicate when assign (PreemptionIndAss) ....................2-314
2.16.20 Forced release allowed when handover (PreemptionIndHo) .................2-315
2.16.21 Forced handover indication for assign (ForcedHolndAss) .....................2-316
2.16.22 Forced handover indication for handover (ForcedHolndHo) ..................2-317
2.16.23 Wait resource timer after forced release (ForceRelWait).......................2-318
2.16.24 Wait resource timer after forced handover (ForceHoWait, 100ms).........2-320
2.16.25 Enough low priority for preemption (LowestPriority)..............................2-321
2.16.26 Enough call duration for preemption (LongCallDuration).......................2-322
2.16.27 Forced handover target penalty time (ForceHoPenalty)........................2-323
2.16.28 Priority of emergency service (EmergServicelPrio)...............................2-324
2.17 User Access Flow Control Parameters............................................................2-325
2.17.1 Access class parameter config select (AccConfigSelect)........................2-325
2.17.2 First barred class 0 ~ First barred class 3
(FirstBarredClass_0~FirstBarredClass_3)..............................................2-326
2.17.3 Barred class windows 0 ~ Barred class windows 3
(BarredClassWindows_0~BarredClassWindows_3)................................2-327
2.17.4 Barred time step 0 ~ Barred time step 3
(BarredTimeStep_0~BarredTimeStep_3) ...............................................2-329
2.17.5 Access Control (AccessControl) ...........................................................2-330
2.18 UPPB Resource Alarm Parameters ................................................................2-331
2.18.1 Enable UPPB resource alarm (UppbResAlarmEnable)...........................2-331
2.18.2 Alarm threshold of failure ratio for allocating memory
(UppbResAlarmThs_0).........................................................................2-332
2.18.3 Alarm threshold of use ratio for mac instance (UppbResAlarmThs_1) ......2-333
2.18.4 Alarm threshold of use ratio for bssgp instance and tlli index
(UppbResAlarmThs_2).........................................................................2-334
2.18.5 Alarm threshold of use ratio for mac-tlli index (UppbResAlarmThs_3) ......2-335
2.18.6 Alarm threshold of use ratio for radio channel instance
(UppbResAlarmThs_4).........................................................................2-336
2.18.7 Alarm threshold of use ratio for TS instance (UppbResAlarmThs_5) .......2-337
2.18.8 Duration of exceeding alarm threshold (OverThsDuration) .....................2-339
2.19 AMR-WB Parameter ......................................................................................2-340
2.19.1 Thresholds of AMR-WB (AmrWBThresholds) ........................................2-340
X
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

2.19.2 Hysteresis of AMR-WB (AmrWBHysteresis) ..........................................2-341


2.20 Iur-g Parameter .............................................................................................2-342
2.20.1 Report characteristics (ReportType)......................................................2-342
2.20.2 Report periodicity unit (RepPeriodUnit) .................................................2-343
2.20.3 Report periodicity value (RepPeriodValue) ............................................2-344
2.20.4 Load/RT Load/NRT Load measurement threshold 1
(MeasThr1_0~MeasThr1_2) .................................................................2-345
2.20.5 Load/RT Load/NRT Load measurement threshold 2
(MeasThr2_0~MeasThr2_2) .................................................................2-346
2.20.6 Measurement hysteresis time (MeasHys,10ms).....................................2-347
2.20.7 Event report periodicity (EveRepPeriod,10ms) ......................................2-348
2.20.8 Measurement timer (MeasTimer,10ms) .................................................2-349
2.20.9 Measurement max retry number (MeasMaxRetryNum) ..........................2-350
2.20.10 Information report type (InfoReportType) .............................................2-351
2.20.11 Measurement type (MeasType)...........................................................2-352
2.20.12 Support of 2g request Iur-g (IurgOf2gReq) ..........................................2-352
2.21 Ater Timer Parameters...................................................................................2-353
2.21.1 Ater wait SCCP connection timer (TAterWaitConn) ................................2-353
2.21.2 Ater wait resource timer (TWaitAterRes) ...............................................2-355
2.21.3 Ater wait resource release timer (TAterWaitRel).....................................2-356
2.21.4 Ater handover monitor timer (TAterMoniterHO)......................................2-357
2.21.5 Ater wait resource acknowledge timer (TWaitAterResAck) .....................2-358
2.21.6 Ater block circuit timer (TAterCicBlk) .....................................................2-359
2.21.7 Ater block circuit group timer (TAterBlkCicGrp) ......................................2-360
2.21.8 Ater reset circuit timer (TAterRstCic) .....................................................2-361
2.21.9 Ater reset timer (TAterRst) ...................................................................2-362
2.21.10 Ater reset guard timer (TITCRst).........................................................2-363
2.21.11 Ater block a interface circuit timer (TBlkACic).......................................2-364
2.21.12 Ater block a interface circuit group timer (TBlkACicGrp) .......................2-366

Chapter 3 External Cell Parameters.......................................................... 3-1


3.1 GERAN External Cell Parameters ....................................................................... 3-1
3.1.1 User Label ............................................................................................... 3-1
3.1.2 External cell ID (Geran EcellID)................................................................. 3-2
3.1.3 Cell type (CellType) .................................................................................. 3-3
3.1.4 MCC (MCC)............................................................................................. 3-4
3.1.5 MNC (MNC)............................................................................................. 3-5
3.1.6 FreqBand (FreqBand)............................................................................... 3-6
3.1.7 BCCH arfcn (BcchArfcn) ........................................................................... 3-7
XI
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

3.1.8 LAC (LAC) ............................................................................................... 3-8


3.1.9 CI (CI) ..................................................................................................... 3-9
3.1.10 NCC (NCC).......................................................................................... 3-10
3.1.11 BCC (BCC) ...........................................................................................3-11
3.1.12 GPRS service support (PsSupport)........................................................ 3-12
3.1.13 Cell reselection offset (ReselOff_0)........................................................ 3-13
3.1.14 Cell reselection offset (ReselOff_1)........................................................ 3-14
3.1.15 Cell reselection temporary offset (TempOffset_0).................................... 3-15
3.1.16 Cell reselection temporary offset (TempOffset_1).................................... 3-17
3.1.17 Penalty time of cell reselection (PenalTime_0)........................................ 3-18
3.1.18 Penalty time of cell reselection (PenalTime_1)........................................ 3-20
3.1.19 HSC exist (HCS_EXIST_0) ................................................................... 3-21
3.1.20 HSC exist (HCS_EXIST_1) ................................................................... 3-22
3.1.21 Threshold of HSC signal level (HCS_THR_0)......................................... 3-23
3.1.22 Threshold of HSC signal level (HCS_THR_1)......................................... 3-24
3.1.23 HCS priority (PrioClass_0) .................................................................... 3-25
3.1.24 HCS priority (PrioClass_1) .................................................................... 3-26
3.1.25 Allow SOLSA MS to access (EXC_ACC) ............................................... 3-27
3.1.26 Cell reselection status (CellBarAc2) ....................................................... 3-28
3.1.27 LSA ID (LSA_Id)................................................................................... 3-31
3.1.28 RAC (RAC) .......................................................................................... 3-32
3.1.29 Access minimal signal level (RxLevAsMin_0) ......................................... 3-33
3.1.30 Access minimal signal level (RxLevAsMin_1) ......................................... 3-35
3.1.31 Maximum initial access signal level (MsTxMaxCCH_0) ........................... 3-36
3.1.32 Maximum initial access signal level (MsTxMaxCCH_1) ........................... 3-38
3.2 UTRAN External Cell Parameters...................................................................... 3-40
3.2.1 Basic property........................................................................................ 3-40
3.2.2 Others ................................................................................................... 3-54
3.3 LTE External Cell Parameters ........................................................................... 3-65
3.3.1 User label (UserLabel)............................................................................ 3-65
3.3.2 LTE CELL Identification (LTECELLID)...................................................... 3-66
3.3.3 MCC (MCC)........................................................................................... 3-67
3.3.4 MNC (MNC)........................................................................................... 3-68
3.3.5 LTE CELL Identification (ENBID) ............................................................. 3-69
3.3.6 LTE CELL TYPE (CellTypeLTE) .............................................................. 3-70
3.3.7 Tracking area code (TAC) ....................................................................... 3-71
3.3.8 Physical layer cell identity of LTE CELL (PCID) ........................................ 3-72

XII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

3.3.9 The attribute of LTE NodeB (ENBInd) ...................................................... 3-72


3.3.10 specified EARFCN of E-UTRAN cells (ArfcnLTE).................................... 3-73
3.3.11 the minimum value of the channel bandwidth (MeasureBandwidth) .......... 3-74

Chapter 4 Cell Parameters......................................................................... 4-1


4.1 Basic Parameters 1 ............................................................................................ 4-1
4.1.1 User Label ............................................................................................... 4-1
4.1.2 Site ID ..................................................................................................... 4-2
4.1.3 BSC (BSCID) .................................................................................... 4-3
4.1.4 BTS ID (BtsId).......................................................................................... 4-4
4.1.5 Cell Type (CellType) ................................................................................. 4-6
4.1.6 MCC (MCC)............................................................................................. 4-7
4.1.7 MNC (MNC)............................................................................................. 4-8
4.1.8 LAC (LAC) ............................................................................................... 4-9
4.1.9 CI (CI) ................................................................................................... 4-10
4.1.10 NCC (NCC)...........................................................................................4-11
4.1.11 BCC (BCC) .......................................................................................... 4-12
4.1.12 Frequency band (FreqBand) ................................................................. 4-13
4.1.13 Subcell used (SubCellUsed).................................................................. 4-14
4.1.14 Frequency Band of subcell (SubFreqBand) ............................................ 4-15
4.1.15 ARFCN list (CaArfcnList) ...................................................................... 4-16
4.1.16 GPRS service support (PsSupport)........................................................ 4-17
4.1.17 Dynamic HR support indication (DynaHREnable) ................................... 4-18
4.1.18 Dynamic HR channel allocation algorithm (DHRAlgrithm)........................ 4-19
4.1.19 CBC support (SmsCbUsed) .................................................................. 4-21
4.1.20 Threshold for TRX switched from FR to HR (HRThs) .............................. 4-22
4.1.21 PS busy threshold (Info_1_16) .............................................................. 4-23
4.1.22 Use cell AMR parameter (UseCellAMRParam) ....................................... 4-24
4.1.23 Support AMR-WB (SUPPORTAMRWB) ................................................. 4-25
4.1.24 Support CS paging prefer PS Assignment (CsPagingPrefer) ................... 4-26
4.1.25 Common control channel configuration (CcchConf) ................................ 4-27
4.1.26 Template file......................................................................................... 4-29
4.2 Basic Parameters 2 .......................................................................................... 4-30
4.2.1 TA Max (TaMax) ..................................................................................... 4-30
4.2.2 TA MIN (TaMin) ...................................................................................... 4-31
4.2.3 TA allowed (TaAllowed)........................................................................... 4-32
4.2.4 PCH load indication period (CcchLoadIndPrd).......................................... 4-33
4.2.5 Periodical location updating timer (T3212) ............................................... 4-34

XIII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.2.6 Protection period for access attempt (T3122) ........................................... 4-36


4.2.7 Multi-band report indication (MulbandReport) ........................................... 4-37
4.2.8 Coefficient of BVC bucket size (Info_2_0) ................................................ 4-39
4.2.9 CCCH load indication (RACH) (CcchLoadINDThs_0)................................ 4-40
4.2.10 CCCH load indication (PCH) (CcchLoadINDThs_1) ................................ 4-41
4.2.11 8PSK modulating power attenuation level (Tn7Lowerlevel)...................... 4-42
4.2.12 Repeated ACCH support (RepeatACCH) ............................................... 4-43
4.2.13 Start PA power off (StartPAPowerOff) .................................................... 4-44
4.2.14 Switch flag of cell TRX power off (StartTRXPowerOff)............................. 4-45
4.2.15 Support intelligent cell shuttingdown (CellShuttingDown) ........................ 4-46
4.2.16 Upper Site Id (UPSITEID) ..................................................................... 4-48
4.2.17 Upper Cell Id (UPBTSID) ...................................................................... 4-49
4.2.18 AMR codec adjust mode (AmrAdjMode)................................................. 4-50
4.2.19 AMR codec adjust interval (AmrAdjInterval)............................................ 4-51
4.2.20 HR channel fragment repacking support (HRDfragSupport)..................... 4-52
4.2.21 Idle FR threshold For HR defrag (Info_0_8)............................................ 4-53
4.2.22 Busy threshold for HR defrag (Info_1_24) .............................................. 4-55
4.2.23 HR channel percentage threshold (HRTsPercentage) ............................. 4-56
4.2.24 Threshold of AMR HR (AmrHRThs) ....................................................... 4-57
4.2.25 Handover from FR to HR due to high load support (FRThrHoSupport) ..... 4-58
4.2.26 Intra-handover from HR to FR due to bad quality (HRTFRHOSupport) ..... 4-59
4.2.27 Start PA output voltage tuning (Info_0_0) ............................................... 4-60
4.2.28 Enable RRU of cell power off (RRUPowerOff) ........................................ 4-61
4.2.29 The switch of CIR report (ReportCIR) .................................................... 4-62
4.2.30 The L2 frame of Lapdm fill random value (LapdmL2Cfg) ......................... 4-63
4.2.31 NCC permitted (NccPermitted) .............................................................. 4-64
4.2.32 Support allocating channel by TA (AllocChlByTA) ................................... 4-65
4.2.33 The TA threshold of allocating channel in BCCH (TaThsOfBCCH)............ 4-66
4.2.34 Cell PowerOff based on traffic load (PwDownLoadInd)............................ 4-67
4.2.35 Support handover from HR to FR due to low load (HRTFRHOSupport2) ..... 4-68
4.2.36 TRX PowerOff time bitmap (DownPowerBmp)........................................ 4-69
4.3 Basic Parameters 3 .......................................................................................... 4-70
4.3.1 Average bursts count surveyed by RACH (AvgSlots) ................................ 4-70
4.3.2 RACH receiving signal level threshold for busy burst (RachBusyThs) ........ 4-71
4.3.3 RACH load indication period (OverloadPrd) ............................................. 4-72
4.3.4 BA show (BcchBaInd)............................................................................. 4-73
4.3.5 MIN received signal level to access (RxLevAccessMin) ............................ 4-74

XIV
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.3.6 MAX number of re-transmitting events times (MRetrans)........................... 4-76


4.3.7 Number of slots to spread transmission (TxInteger) .................................. 4-78
4.3.8 Control channel MAX power level (MsTxPwrMaxCch)............................... 4-79
4.3.9 Number of multi-frames of the PCH (BsPaMframs) ................................... 4-81
4.3.10 Interval of SDCCH re-sending PHY info message (T3105d) .................... 4-82
4.3.11 Interval of TCH re-sending PHY info message (T3105f) .......................... 4-84
4.3.12 MAX resending times for physical information (NY1)............................... 4-85
4.3.13 Number of blocks reserved for AGCH (BsAgBlkRes) .............................. 4-86
4.3.14 BSS radio link timer's max value for AMR FR
(BsRadioLkTmOutForAMRFR) .............................................................. 4-87
4.3.15 BSS radio link timer's max value for AMR HR
(BsRadioLkTmOutForAMRHR) .............................................................. 4-89
4.3.16 BSS radio link timers max value for AMR WFS
(BsRadioLkOutAMRWFS) ..................................................................... 4-90
4.3.17 BSS radio link timer's max value for AMR OWFS
(BsRadioLkOutAMROWFS)................................................................... 4-91
4.3.18 BSS radio link timers max value for AMR OWHS
(BsRadioLkOutAMROWHr) ................................................................... 4-93
4.3.19 LAPDM timer used for controlling the SDCCH channel. (T200_0)............ 4-94
4.3.20 Lapdm Timer for controlling FACCH/full rate channel (T200_1)................ 4-96
4.3.21 Lapdm Timer for controlling FACCH/half rate channel (T200_2)............... 4-97
4.3.22 Lapdm Timer for controlling SACCH with tch sapi0 channel (T200_3) ...... 4-98
4.3.23 Lapdm Timer for controlling SACCH with sdcch channel (T200_4)........... 4-99
4.3.24 Lapdm Timer for controlling sdcch sapi3 channel (T200_5) ....................4-100
4.3.25 Lapdm Timer for controlling SACCH with TCH sapi3 channel
(T200_6) .............................................................................................4-102
4.4 Optional Parameters........................................................................................4-103
4.4.1 Early class-mark sending control (ECSC)................................................4-103
4.4.2 IMSI attach/detach allowed (ImsIadAllowed) ...........................................4-104
4.4.3 Cell bar access (CellBarAccess).............................................................4-105
4.4.4 Call re-establishment allowed (CallReestablish) ......................................4-106
4.4.5 Downlink discontinuous transmission allowed (DtxDwlink) .......................4-107
4.4.6 Uplink discontinuous transmission (DtxUplinkBcch) .................................4-109
4.4.7 Emergency call allowed (EmergencyCall) ............................................... 4-110
4.4.8 Support Emergency call preemption (EmergCallPreempt)........................ 4-111
4.4.9 Cell bar qualify (CellBarQualify).............................................................. 4-113
4.4.10 Access class parameter config select (AccConfigSelect)........................ 4-114
4.4.11 Cell access control support (UseCellAcc) .............................................. 4-115

XV
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.4.12 Adopt Precise Paging for Circuit Switched Service (CsPrecisePag) ........ 4-116
4.4.13 Adopt Precise Paging for Packet Switched Service (PsPrecisePag)........ 4-117
4.4.14 VPC Age Time (VpcAgeTime) .............................................................. 4-118
4.4.15 HBTS proofread support (HBTSScanSupport)....................................... 4-119
4.4.16 RSSI threshold (RSSIThrd) ..................................................................4-120
4.4.17 Proofread freqband type (GSM1900Support) ........................................4-121
4.4.18 Access Control (AccessControl) ...........................................................4-122
4.4.19 Range of HBTS BARANG (HBTSRange) ..............................................4-124
4.4.20 Paging Hole Timer (PagHoleTimer) ......................................................4-125
4.4.21 Mobile Orignated Short Message intercept (MOSmsIntercept)................4-126
4.4.22 Mobile Terminated Short Message intercept (MTSmsIntercept) ..............4-127
4.4.23 NCC Config Parameter (NccCfgPara) ...................................................4-128
4.4.24 RxQual Threshlod (RQThreshold) ........................................................4-129
4.4.25 TCH Allocation Threshold For Dual-Frequency Network
(DualFreqNetTchThs) ...........................................................................4-130
4.4.26 Diversity Combine Mode (DivCombMode).............................................4-131
4.4.27 SubCell Channel Allocation Parameter (CSAllocSC)..............................4-131
4.4.28 Is Enhanced Dual-Frequency Network Support (IsDualFreqSup) ............4-132
4.5 Cell Selection Parameters................................................................................4-133
4.5.1 the maximum thresholds of Utran reselection (UtranHighThresh) .............4-133
4.5.2 the minimum thresholds of Utran reselection (UtranLowThresh) ...............4-134
4.5.3 Minimum RX level for Utran cells (UtranQRXLEVMIN) .............................4-135
4.5.4 The maximum thresholds of EUtran reselection (EUtranHighThresh) ........4-136
4.5.5 The minimum thresholds of EUtran reselection (EUtranLowThresh)..........4-137
4.5.6 Minimum RX level for EUtran cells (EUtranQRXLEVMIN) ........................4-138
4.5.7 The maximum RSRQ thresholds for EUtran reselection
(EUtranHighThreshQ) ..........................................................................4-139
4.5.8 The minimum RSRQ thresholds of EUtran reselection
(EUtranLowThreshQ) ...........................................................................4-140
4.5.9 Minimum RSRQ for EUtran cells (EUtranQQUALMIN) .............................4-141
4.5.10 Additional reselection parameter indication (AdditionReselPI).................4-142
4.5.11 Cell reselection parameter indication (CellReselPI) ................................4-143
4.5.12 Cell reselection offset (ReselOffset) ......................................................4-144
4.5.13 Temporary offset (TemporaryOffset)......................................................4-147
4.5.14 Penalty time (PenaltyTime) ..................................................................4-148
4.5.15 Cell reselecting hysteresis level (ReselHysteresis).................................4-149
4.5.16 New setup cause indication (NECI).......................................................4-151
4.5.17 Power offset indication (PowerOffsetInd)...............................................4-153
XVI
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.5.18 Power offset (PowerOffset) ..................................................................4-154


4.5.19 Based on priority Cell re-selection Switch (PrioReselSupport) ................4-155
4.5.20 Priority of GSM cells (ServCellPrio) ......................................................4-156
4.5.21 Threshold of serving cell that used by priority Cell re-selection algorithm
(THRESHPRIORYSEARCH) ................................................................4-156
4.5.22 Threshold that Allow MS re-select to lower priority Cell
(THRESHGSMLOW)............................................................................4-157
4.5.23 Hysteresis of priority reselection algorithm (HysteresisofPRiority) ...........4-158
4.5.24 Time hysteresis of priority reselection algorithm
(TimeHysteresisofReS) ........................................................................4-159
4.5.25 The default priority of Utran Cells (UtranDefaultPrio)..............................4-160
4.5.26 The default priority of EUtran Cells (EUtranDefaultPrio) .........................4-161
4.6 Service Process Additional Parameters ............................................................4-162
4.6.1 Directed retry indication (DrInd_0) ..........................................................4-162
4.6.2 External directed retry indication (DrInd_1)..............................................4-163
4.6.3 Queue allowed when assign (QueueInd_0) .............................................4-164
4.6.4 Queue allowed when handover (QueueInd_1).........................................4-165
4.6.5 Preemption allowed when assign (PreemptionInd_0) ...............................4-166
4.6.6 Preemption allowed when handover (PreemptionInd_1)...........................4-168
4.6.7 When assigned forced handover (ForcedHoInd_0) ..................................4-169
4.6.8 Forced handover allowed when handover (ForcedHoInd_1) .....................4-170
4.6.9 Number of candidate cells for handover (CandidateNum).........................4-171
4.6.10 Fast average indication (FastAvg) ........................................................4-172
4.6.11 BCCH switch allowed (CanBcchExch)...................................................4-173
4.6.12 SDCCH dynamic configuration allowed (CanSdcchDyn) ........................4-174
4.6.13 Minimal resource threshold (ResourceThs) ...........................................4-175
4.6.14 Base-band hopping TRX exchange support (Info_0_3) ..........................4-176
4.6.15 Support NCell of channel release (NCELLINDOFCHLREL) ....................4-177
4.6.16 RelEUtranStrategy (RelEUtranStrategy)................................................4-178
4.6.17 RelEUtranPrio (RelEUtranPrio).............................................................4-179
4.6.18 Allowed FACCH call setup after emergency call (FacchCallInd_0) ..........4-180
4.6.19 Allowed FACCH call setup when page respond (FacchCallInd_1) ...........4-181
4.6.20 Allowed call setup on FACCH (FacchCallInd_2) ....................................4-182
4.6.21 Allowed call reestablished on FACCH (FacchCallInd_3).........................4-183
4.7 System Parameters .........................................................................................4-184
4.7.1 Interference average period (InterfAvgPrd)..............................................4-184
4.7.2 Interference Band Boundary (InterfBoundary_0)......................................4-185
4.7.3 Interference Band Boundary (InterfBoundary_1)......................................4-187
XVII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.7.4 Interference Band Boundary (InterfBoundary_2)......................................4-188


4.7.5 Interference Band Boundary (InterfBoundary_3)......................................4-190
4.7.6 Interference Band Boundary (InterfBoundary_4)......................................4-191
4.7.7 Interference Band Boundary (InterfBoundary_5)......................................4-193
4.7.8 MAX value of MS Radio link timeout (MsRadioLKTmOut) ........................4-194
4.7.9 Radio link failure criterion (ConFailCriterion) ...........................................4-195
4.7.10 MAX value of BSS Radio link timeout (BsRadioLKTmOut) .....................4-197
4.7.11 Receiving level threshold (RxLevThs) ...................................................4-198
4.7.12 Receiving quality threshold (RxQualThs)...............................................4-199
4.7.13 Radio link failure checking period (RxLevQualprd) .................................4-200
4.7.14 AMR FR (MsRadioLkTmOutAMRFR)....................................................4-201
4.7.15 AMR HR (MsRadioLkTmOutAMRHR) ...................................................4-203
4.7.16 AMR WFS (MsRadioLkOutAMRWFS)...................................................4-204
4.7.17 AMR-WB OWFS (MsRadioLkOutAMROWFS) .......................................4-205
4.7.18 AMR-WB OWHR (MsRadioLkOutAMROWHR)......................................4-206
4.8 AMR Half Method Parameters..........................................................................4-207
4.8.1 AMR Half Active Codec Set (AmrHalfAcs)...............................................4-207
4.8.2 Thresholds of AMR (AmrThresholds) ......................................................4-208
4.8.3 Hysteresis of AMR (AmrHysteresis)........................................................4-210
4.8.4 Initial codec mode (IsAmrlCM) ............................................................... 4-211
4.8.5 Start mode (AmrStartMode) ...................................................................4-212
4.8.6 Enable noise control (IsAmrNscb) ..........................................................4-214
4.9 AMR Full Method Parameters ..........................................................................4-215
4.9.1 AMR full Active Codec Set (AmrFullAcs) .................................................4-215
4.9.2 Thresholds of AMR (AmrThresholds) ......................................................4-216
4.9.3 Hysteresis of AMR (AmrHysteresis)........................................................4-218
4.9.4 Initial codec mode (IsAmrICM) ...............................................................4-219
4.9.5 Start mode (AmrStartMode) ...................................................................4-221
4.9.6 Enable noise control (IsAmrNscb) ..........................................................4-222
4.10 Other Parameters..........................................................................................4-223
4.10.1 Preprocessing indication (Preprocess) ..................................................4-223
4.10.2 Reserved rate of EMLPP (EMLPPThs) .................................................4-225
4.10.3 Use cell EMLPP Threshold (UseCellEmlppThs).....................................4-226
4.10.4 Frequency offset correct support (Info_0_1) ..........................................4-227
4.10.5 Maximum power on handover command support (Info_0_2)...................4-228
4.10.6 MR Report Time Bmp (MrRptTimeBmp)................................................4-229
4.10.7 Non Cipher Mode support (CipherMode_0_0) .......................................4-230

XVIII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.10.8 Cipher Mode support A5/1 (CipherMode_0_1).......................................4-231


4.10.9 Cipher Mode support A5/2 (CipherMode_0_2).......................................4-232
4.10.10 Cipher Mode support A5/3 (CipherMode_0_3).....................................4-233
4.10.11 Cipher Mode support A5/4 (CipherMode_0_4) .....................................4-234
4.10.12 Cipher Mode support A5/5 (CipherMode_0_5).....................................4-235
4.10.13 Cipher Mode support A5/6 (CipherMode_0_6).....................................4-236
4.10.14 Cipher Mode support A5/7 (CipherMode_0_7).....................................4-237
4.10.15 Cipher mode priority1 ~ Cipher mode priority7 (CipherMode_1~
CipherMode_7) ....................................................................................4-238
4.10.16 Channel Select Strategy (ChanSelectStrategy)....................................4-239
4.10.17 Info_3 ...............................................................................................4-241
4.10.18 Info_4 ...............................................................................................4-241
4.10.19 Info_5 ...............................................................................................4-242
4.10.20 Info_6 ...............................................................................................4-243
4.10.21 Info_7 ...............................................................................................4-244
4.11 GPRS Basic Parameters ................................................................................4-245
4.11.1 SGSN ID (SGSNID) .............................................................................4-245
4.11.2 NSEI (NSEI)........................................................................................4-246
4.11.3 BVCI (BVCI)........................................................................................4-247
4.11.4 RAC (RAC) .........................................................................................4-248
4.11.5 PS service busy level (PsBusyLevel) ....................................................4-250
4.11.6 Enable cell PS push down (PSPushDown) ............................................4-251
4.12 GPRS Other Parameters 1.............................................................................4-252
4.12.1 Additional reselection parameter indicator (AddResPI2) .........................4-252
4.12.2 SI13 sending position (Si13Locate).......................................................4-253
4.12.3 Route area color code (RaColor) ..........................................................4-254
4.12.4 Minimal number of idle CS channel (CsChansThs) ................................4-255
4.12.5 Packet access priority threshold (PriAcThr) ...........................................4-256
4.12.6 Packet System Information Send Speed (SendSpeed (PSI2, PSI3,
PSI3BIS, PSI4, PSI5, PSI13, PSI3ter, PSI8, PSI3quater)).......................4-258
4.12.7 Overload report period on PRACH (OvLoadPer)....................................4-259
4.12.8 Link error counter (RLTimeout) .............................................................4-260
4.12.9 PRACH receiving signal level threshold (PrachBusyT) ...........................4-261
4.12.10 Average measuring bursts number on PRACH (MeaAvgSlot) ...............4-262
4.12.11 Buffer threshold of paging message (PccchIndTh_0)............................4-263
4.12.12 Queue length threshold in 64 multi-frame paging period
(PccchIndTh_1) ...................................................................................4-264
4.12.13 PRACH overload threshold ratio (PccchIndTh_2).................................4-265
XIX
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.13 GPRS Other Parameters 2.............................................................................4-266


4.13.1 DTM support (DTMSupport) .................................................................4-266
4.13.2 DTM Enhance Capability (DTMEnhanceCapa) ......................................4-267
4.13.3 CCN mode support (CCNActive) ..........................................................4-268
4.13.4 Cell support system message status flow (SIStatusInd) .........................4-269
4.13.5 Allow SOLSA MS to access (Exc_Acc) .................................................4-271
4.13.6 CCCH SplitPGCycle support (SpgcSuport) ...........................................4-272
4.13.7 Extended paging support (EpageMode) ................................................4-273
4.13.8 PSI status support (PsiStatInd).............................................................4-274
4.13.9 Cell support extendable uplink TBF (Ext_UTBF) ....................................4-276
4.13.10 Uplink delay time (UlDelayTime) .........................................................4-277
4.13.11 Interval number of GPRS TBF downlinks RRBP
(GPRSDIRrbpInterVal) .........................................................................4-278
4.13.12 Interval number of downlink EGPRS TBFs RRBP
(EGPRSDIRrbpInterVal) .......................................................................4-279
4.13.13 Interval number of uplink GPRS TBFs ACK (GPRSUlAckInterVal)........4-280
4.13.14 Interval number of uplink EGPRS TBFs ACK
(EGPRSUlAckInterVal) .........................................................................4-281
4.13.15 Single block assign offset (Info1_0_0) .................................................4-282
4.13.16 Polling retry times (Info1_0_8) ............................................................4-283
4.13.17 Uplink measurement report period (Ulmeasureperiod)..........................4-284
4.13.18 Calculating period of load on PPCH (LoadPer) ....................................4-285
4.13.19 PSI1 sending period (Psi1RepPer) .....................................................4-286
4.13.20 USF granularity (USFGranularity) .......................................................4-287
4.13.21 Extended uplink dynamic allocation support (ExUpDynSupport) ...........4-288
4.13.22 ABIS time slots reserved for packet service (Info_1_0).........................4-289
4.13.23 The MAX of ABIS for GPRS user (Info_1_8)........................................4-291
4.13.24 GPRS initial downlink allocation by multislot class 1 (Info1_1_4)...........4-292
4.13.25 Service UTRAN CCO support (UTRANCCOSupp)...............................4-293
4.13.26 Strategy of servic UTRAN CCO (CCOStrategy) ...................................4-295
4.13.27 Enable no data during extended uplink TBF mode (INFO1_5_0)...........4-296
4.13.28 Downlink TBF pre-establish support (EarlyDlTBFEstSupp)...................4-297
4.13.29 Downlink Delay time in data TBF Mode (DataTBFDlDelayTime) ...........4-298
4.13.30 Extendable uplink TBF time in data TBF Mode (DataTBFExtUlTime) ......4-299
4.14 GPRS Other Parameters 3.............................................................................4-300
4.14.1 C/I (Sc) ...............................................................................................4-300
4.14.2 ARP (Sa) ............................................................................................4-301
4.14.3 THP (St) .............................................................................................4-303
XX
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.14.4 PS queuing support (PsQueueInd) .......................................................4-304


4.14.5 Max PS Queue Count (PsMaxQueueInstNum) ......................................4-305
4.14.6 PS preemption support (PsPreemptionInd) ...........................................4-306
4.14.7 3G NACC support (Support3GCCN) .....................................................4-307
4.14.8 PS preempt CS support (PSPrmpCSSupport) .......................................4-308
4.14.9 Maximal resource for POC service (POCSrcThs)...................................4-309
4.14.10 Enable uplink interference decision in NC2 (INFO1_5_1) ..................... 4-311
4.14.11 Enable downlink interference decision in NC2 (INFO1_5_2) ................. 4-311
4.14.12 P of uplink interference decision in NC2 (INFO1_5_3)..........................4-312
4.14.13 N of uplink interference decision in NC2 (INFO1_5_8) .........................4-313
4.14.14 P of downlink interference decision in NC2 (INFO1_5_13)....................4-314
4.14.15 N of downlink interference decision in NC2 (INFO1_5_18) ...................4-315
4.14.16 Quality offset of uplink interference in NC2 (INFO1_5_23)....................4-316
4.14.17 Signal offset of uplink interference in NC2 (INFO1_6_0).......................4-317
4.14.18 Quality offset of downlink interference in NC2 (INFO1_6_5) .................4-318
4.14.19 Signal offset of downlink interference in NC2 (INFO1_6_10).................4-319
4.14.20 Num of samples that calculates average of uplink signal level in NC2
(INFO1_6_15)......................................................................................4-320
4.14.21 Num of samples that calculates average of downlink signal level in
NC2 (INFO1_6_20) ..............................................................................4-321
4.14.22 Num of samples that calculates average of uplink quality level in NC2
(INFO1_6_25)......................................................................................4-322
4.14.23 Num of samples that calculates average of downlink quality level in
NC2 (INFO1_7_0)................................................................................4-323
4.14.24 NC2 Distance Windows (NC2DistanceWindow)...................................4-324
4.14.25 Transform from uplink delay to extend (Info1_1_16).............................4-325
4.14.26 Max Num of resend packet assignment (Info1_1_8).............................4-326
4.14.27 Resource adjust for CS preempt (Info1_1_17) .....................................4-327
4.14.28 Subcell selection of PS channel allocation (PSALLOCSC_0) ................4-328
4.14.29 RXLEV threshold in subcell 1 (PSALLOCSC_1) ..................................4-330
4.14.30 RXLEV threshold in subcell 2 (PSALLOCSC_2) ..................................4-332
4.14.31 Multislot allocation of extended range cell support (Info1_7_13)............4-333
4.14.32 Support resource optimizing by service (SuppResOpByService)...........4-334
4.14.33 RxLev P Value (RxLevP)....................................................................4-335
4.14.34 RxLev N Value (RxLevN) ...................................................................4-336
4.14.35 TA P Value (TaP) ...............................................................................4-337
4.14.36 TA N Value (TaN)...............................................................................4-338
4.14.37 SubCell1 PS Busy Threshold (SubCell1PsChanThs) ...........................4-339
XXI
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.14.38 SubCell2 PS Busy Threshold (SubCell2PsChanThs) ...........................4-340


4.14.39 TA threshold for PS channel allocate in subcell1 (TaLevelThs1) ............4-341
4.14.40 TA threshold for PS channel allocate in subcell2 (TaLevelThs2) ............4-342
4.14.41 Resource adjust threshold (ResourceAdjustThs) .................................4-343
4.14.42 Info1_2 .............................................................................................4-344
4.14.43 Info1_3 .............................................................................................4-345
4.14.44 Is Dual-Frequency NC2 Support (DualFreqNC2Sup)............................4-346
4.14.45 Dual-Frequency NC2 Parameter N (DualFreqNC2N) ...........................4-347
4.14.46 Dual-Frequency NC2 Parameter P (DualFreqNC2P)............................4-348
4.14.47 Dual-Frequency NC2 TA Threshold (DualFreqNC2TAThr) ....................4-349
4.14.48 Dual-Frequency NC2 load Threshold (DualCellPsChanThr)..................4-350
4.14.49 NC2 UL RxLevel Threshold (ULRxLevThr) ..........................................4-351
4.14.50 NC2 DL RxLevel Threshold (DLRxLevThr) ..........................................4-352
4.14.51 NC2 UL RxQual Threshold (ULRxQualThr) .........................................4-353
4.14.52 NC2 DL RxQual Threshold (DLRxQualThr) .........................................4-354
4.14.53 avoid Ping-Pang cell reselection Timer (TPingPang) ............................4-355
4.14.54 NC2 Reselection hysteresis Threshold (NC2ResHys) ..........................4-356
4.14.55 NC2 reselection DL RxLevel Threshold (NC2ResThr) ..........................4-357
4.15 GPRS Cell Options Parameters......................................................................4-358
4.15.1 T3168 (T3168) ....................................................................................4-358
4.15.2 T3192 (T3192) ....................................................................................4-359
4.15.3 T3142 (Info1_0_2) ...............................................................................4-361
4.15.4 T3172 (Info1_0_3) ...............................................................................4-362
4.15.5 DRX mode holding timer (DrxTimeMax) ................................................4-364
4.15.6 MAX blocks transmittion in each TS (BsCvMax) ....................................4-365
4.15.7 Packet control acknowledgement type (CtraCKType).............................4-367
4.15.8 Access burst type (AccessType) ...........................................................4-368
4.15.9 N3102 descrease step (PanDec) ..........................................................4-369
4.15.10 N3102 increase step (PanInc) ............................................................4-371
4.15.11 N3102 max (PanMax) ........................................................................4-372
4.15.12 GPRS Phone Init Coding (GPRSInitattselt_0~GPRSInitattselt_3) .........4-374
4.15.13 GPRS phones init code can be changed (InitAttachExch_0) .................4-375
4.16 GPRS NC Survey Parameters........................................................................4-376
4.16.1 Packet idle mode (NcRepPerI) .............................................................4-376
4.16.2 Packet transmission mode (NcRerPerT) ...............................................4-377
4.16.3 Extended measurement report order (MeaOrder) ..................................4-378
4.16.4 Network control order (CtrlOrder)..........................................................4-379

XXII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.16.5 NC2 mode between 2G and 3G (NC2For23G) ......................................4-380


4.16.6 Serving Cell Load Threshold (ServCellLoadThr) ....................................4-381
4.16.7 Serving Cell Capacity Threshold (ServCellCapaThr) ..............................4-382
4.16.8 Cell reselection control switch by serving cell traffic busy
(PsTrafResel) ......................................................................................4-383
4.16.9 NC hold time in non-drx mode (NcNoDrxPer) ........................................4-384
4.16.10 Extended measurement report order (ExMeaOrder).............................4-385
4.16.11 Type of extended measurement report (ExtRepType) ...........................4-386
4.16.12 Report period of extended measurement (ExtRepPer) .........................4-387
4.16.13 The size of test report's slip window (Wnd) ..........................................4-388
4.16.14 Minimum measurement reports in slip window to avoid penalty
(AllowedRepNum)................................................................................4-389
4.17 GPRS Power Control Parameters...................................................................4-391
4.17.1 Filter period in the packet idle mode (T_AVG_W)...................................4-391
4.17.2 Filter period in packet transmission mode (T_AVG_T)............................4-392
4.17.3 PSI4 sending mark (Psi4Send).............................................................4-393
4.17.4 Power control measurement channel (PcMeasChan).............................4-394
4.17.5 Power control parameter (Alpha) ..........................................................4-395
4.17.6 Filter constant of power control (N_AVG_I)............................................4-396
4.17.7 Power descending on PBCCH (Pb) ......................................................4-397
4.18 GPRS Cell Reselection Parameters................................................................4-398
4.18.1 Cell reselection offset (ReselOff_0).......................................................4-398
4.18.2 Cell reselection offset2 (ReselOff_1) .....................................................4-399
4.18.3 Temporary offset of cell reselection (TempOffset_0) ...............................4-400
4.18.4 Temporary offset of cell reselection2 (TempOffset_1) .............................4-401
4.18.5 Penalty time of cell reselection 0 (PenalTime_0)....................................4-402
4.18.6 Penalty time of cell reselection 1 (PenalTime_1)....................................4-404
4.18.7 Interval of reselecting the same cell (T_Resel_0)...................................4-405
4.18.8 Interval of reselecting the same cell 2 (T_Resel_1) ................................4-406
4.18.9 Threshold of HSC signal level (HCS_Thr_0)..........................................4-407
4.18.10 Threshold of HSC signal level 2 (HCS_Thr_1) .....................................4-408
4.18.11 HCS Priority (PrioClass_0) .................................................................4-409
4.18.12 HCS Priority 2 (PrioClass_1) ..............................................................4-410
4.18.13 C31 hysteresis (C31_Hyst_0) ............................................................. 4-411
4.18.14 C31 hysteresis 2 (C31_Hyst_1) ..........................................................4-412
4.18.15 GPRS cell reselection hysteresis (ReselHys_0) ...................................4-413
4.18.16 GPRS cell reselection hysteresis 2 (ReselHys_1) ................................4-415
4.18.17 Routing reselection hysteresis (RaReselHys_0)...................................4-416
XXIII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.18.18 Routing reselection hysteresis 2 (RaReselHys_1)................................4-417


4.18.19 Random access attempt permitted (RadAcRetry_0).............................4-419
4.18.20 Random access attempt permitted 2 (RadAcRetry_1) ..........................4-420
4.18.21 Usage of cell reselection offset (C32_Qual_0) .....................................4-421
4.18.22 Usage of cell reselection offset 2 (C32_Qual_1) ..................................4-422
4.18.23 GPRS access minimal signal level 1 (RxLevAsMin_0)..........................4-423
4.18.24 GPRS access minimal signal level 2 (RxLevAsMin_1)..........................4-424
4.18.25 Priority threshold (Prio_Thr) ...............................................................4-426
4.18.26 HCS exist (HCS_Exist_0)...................................................................4-426
4.18.27 HCS exist 2 (HCS_Exist_1) ................................................................4-428
4.18.28 GPRS MAX initial access signal level (MsTxMaxCch_0) ......................4-429
4.18.29 GPRS MAX initial access signal level 2 (MsTxMaxCch_1)....................4-430
4.18.30 LSA ID (LSA_Id)................................................................................4-432
4.18.31 LSA Offset (LSA_Offset) ....................................................................4-433
4.19 GPRS Channel Parameters ...........................................................................4-434
4.19.1 PAGCH reserved blocks (PagBlkRes)...................................................4-434
4.19.2 PBCCH reserved blocks (PbcchBlks)....................................................4-435
4.19.3 PRACH reserved blocks (PrachBlks) ....................................................4-436
4.19.4 Interval range of packet access attempt (TxInt)......................................4-437
4.19.5 Interval period of packet access attempt (S) ..........................................4-438
4.19.6 MAX Times of Attempt (MaxRetrans) ....................................................4-439
4.19.7 Access control level (AccCtrlClass).......................................................4-440
4.19.8 Access Persistent Level (PersistLev) ....................................................4-442
4.19.9 Subscriber occupying other preference channel support
(HybridOccuSupp) ...............................................................................4-443
4.19.10 PS subscriber moving out of other preference channel support
(AllowPsMove).....................................................................................4-444
4.19.11 CS subscriber moving support (AllowCsMove).....................................4-445
4.19.12 Threshold of GPRS/GPRS,EDGE/EDGE service moving
(SfPreferBusyThs) ...............................................................................4-446
4.19.13 Threshold of GPRS/EDGE service moving (OpPreferBusyThs) ............4-447
4.19.14 PS channel expand (Info1_1_18)........................................................4-449
4.19.15 Idle TCH threshold for PS channel expand (Info1_1_24) ......................4-450
4.19.16 Maximum PS uplink user per ts (MaxPsUserPerTs_0)..........................4-451
4.19.17 Max PS downlink user per TS (MaxPsUserPerTs_1) ............................4-452
4.19.18 Support dynamic channel move (DynChMove) ....................................4-453
4.19.19 Idle static TCH THS for dynamic channel move
(IdleTCHForDChMove,%).....................................................................4-454
XXIV
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.19.20 PS channel alloc reduction support (SuppReducePd) ..........................4-455


4.19.21 Initial limit threshold of PDTCH alloc (LmtThreshold_0) ........................4-456
4.19.22 Medium limit threshold of PDTCH alloc (LmtThreshold_1) ....................4-457
4.19.23 Maximum limit threshold of PDTCH alloc (LmtThreshold_2) .................4-458
4.19.24 Damping of PDTCH alloc from limit to non-limit (LmtThreshold_3) ........4-459
4.20 PS Handover Parameters ..............................................................................4-460
4.20.1 PS handover support (HandoverSupp)..................................................4-460
4.20.2 ACK of PS handover command (HOCommandAck) ...............................4-461
4.20.3 Blind transmission support (BlindTransSupp) ........................................4-462
4.20.4 Optimised handover support (OptimizeHOSupp) ...................................4-463
4.20.5 Send handover access in synchronised handover (SendAccessSync) ......4-464
4.20.6 Send handover access in pre-synchronised handover
(SendAccessPreSync) .........................................................................4-465
4.20.7 Reset RLC (RlcStateReset)..................................................................4-466
4.20.8 Trigger PS handover by PCCN (EnablePCCNTrigHO) ...........................4-467
4.20.9 Early get system information in intra-BSS handover
(EarlyGetSysIntra) ...............................................................................4-468
4.21 EDGE Parameters.........................................................................................4-469
4.21.1 Max number of GTTP lapdm frame (GttpLapdmNum) ............................4-469
4.21.2 EGPRS packet channel request access program support
(EgprsPacketChreq).............................................................................4-470
4.21.3 Uplink LA+IR quality control support (IrSupportUp) ................................4-471
4.21.4 Take Preemptive transmit bit function (PreemptivetRans) .......................4-472
4.21.5 Average filter period for uplink BEP (BEPperiodUp) ...............................4-474
4.21.6 Average filter period for downlink BEP (BEPperiodDown).......................4-475
4.21.7 EGPRS phone quality measure mode (LinkQuameaMode) ....................4-476
4.21.8 EDGE initial downlink allocation by multislot class1 (Info1_1_0) .............4-477
4.21.9 Use parameter of EGPRS Prior to GPRS' in Cell (Info1_7_5) ................4-478
4.21.10 Allocating weights of EGPRS (Info1_7_6) ...........................................4-479
4.21.11 EGPRS uplink init. Coding scheme/EGPRS downlink init. Coding
scheme/EGPRS uplink max. coding schme/EGPRS downlink max.
coding scheme (EGPRSInitAttSelt_0~EGPRSInitAttSelt_3) ....................4-481
4.21.12 EGPRS phones init. Code can be changed (InitAttachExch_1).............4-482
4.21.13 FANR in uplink TBF support (INFO1_4_0)...........................................4-483
4.21.14 FANR in downlink TBF support (INFO1_4_1) ......................................4-484
4.21.15 DLDC support (INFO1_4_2) ...............................................................4-485
4.21.16 RTTI support (INFO1_4_3).................................................................4-486
4.21.17 Enable event-based FANR in downlink TBF (INFO1_4_4) ....................4-487

XXV
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.21.18 Encoding mode of PAN in uplink TBF (INFO1_4_5) .............................4-488


4.21.19 Bep_Period2 of uplink (INFO1_4_6) ...................................................4-489
4.21.20 Bep_Period2 of downlink (INFO1_4_10) .............................................4-490
4.21.21 EGPRS2-A uplink initial coding scheme (EGPRS2AInitAttSelt_0) .........4-491
4.21.22 EGPRS2-A downlink initial coding scheme (EGPRS2AInitAttSelt_1) ......4-492
4.21.23 EGPRS2-A uplink maximum coding scheme
(EGPRS2AInitAttSelt_2) .......................................................................4-493
4.21.24 EGPRS2-A downlink maximum coding scheme
(EGPRS2AInitAttSelt_3) .......................................................................4-494
4.21.25 EGPRS2A MS initial code can be changed (InitAttachExch_2) .............4-495
4.21.26 Enable reduced latency access (RttiAccess) .......................................4-496
4.22 AMR-WB Parameter ......................................................................................4-497
4.22.1 Thresholds for AMR-WB
(AmrWBThresholds_0~AmrWBThresholds_7) .......................................4-497
4.22.2 Hysteresis for AMR-WB
(AmrWBHysteresis_0~AmrWBHysteresis_7) .........................................4-498
4.23 VAMOS Parameter ........................................................................................4-499
4.23.1 User label (UserLabel) .........................................................................4-499
4.23.2 BSC ID (OMCBSCID) ..........................................................................4-500
4.23.3 The identifier of the site (SITEID)..........................................................4-501
4.23.4 BTS ID (BTSID)...................................................................................4-502
4.23.5 Support VAMOS (SupportVAMOS) .......................................................4-503
4.23.6 Support MUTE SAIC detection (MuteSaicDetect) ..................................4-504
4.23.7 Support SAIC AFC detection (SaicAfcDetect)........................................4-505
4.23.8 The priority level of VAMOS pairing (PriorLevelOfPair) ...........................4-506
4.23.9 The load of start VAMOS FR pairing (FRPairLoadThr,%)........................4-507
4.23.10 The load of start VAMOS HR pairing (HRPairLoadThr,%) .....................4-508
4.23.11 The level threshold of Vamos paring (LevThrOfPair).............................4-509
4.23.12 The quality threshold of Vamos paring (QualThrOfPair) ........................4-510
4.23.13 The path loss ratio of candidates (PassLossRatio) ............................... 4-511
4.23.14 The expected received level (ExpectedLev) ........................................4-512
4.23.15 The uplink SCPIR threshold (SCPIR_Up) ............................................4-513
4.23.16 The downlink SCPIR threshold of NON-SAIC MS
(SCPIR_Dn_NoSaic)............................................................................4-514
4.23.17 The downlink SCPIR threshold of SAIC MS (SCPIR_Dn_Saic) .............4-515
4.23.18 The downlink SCPIR threshold of SAIC AFC MS
(SCPIR_Dn_SaicAfc) ...........................................................................4-517
4.23.19 The downlink SCPIR threshold of VAMOS I MS
(SCPIR_Dn_VAMOSI)..........................................................................4-518
XXVI
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.23.20 The downlink SCPIR threshold of VAMOS II MS


(SCPIR_Dn_VAMOSII).........................................................................4-519
4.23.21 P value of total power or SCPIR overflow (PowerOrScpirOverP)...........4-520
4.23.22 N value of total power or SCPIR overflow (PowerOrScpirOverN) ..........4-521
4.23.23 The detection quality threshold (SaicDetQual) .....................................4-522
4.23.24 P value of MUTE SAIC detection (MuteSaicDetectP) ...........................4-524
4.23.25 Thresholdof Frequecy Shift (FreqShiftThre,Hz) ....................................4-525
4.23.26 The time of SAIC AFC detection (SaicAfcDetectTime)..........................4-526
4.23.27 P value of SAIC AFC detection (SaicAfcDetectP).................................4-526
4.23.28 N value of SAIC AFC detection (SaicAfcDetectN) ................................4-528
4.24 Cell Power Parameter....................................................................................4-529
4.24.1 UpLink optimize method for immediate assignment (PwrOptCtrl_0) ........4-529
4.24.2 DownLink optimize method for immediate assignment
(PwrOptCtrl_4).....................................................................................4-530
4.24.3 UpLink optimize method for assignment or intracell handover
(PwrOptCtrl_8).....................................................................................4-531
4.24.4 DownLink optimize method for assignment or intracell handover
(PwrOptCtrl_12)...................................................................................4-532
4.24.5 UpLink optimize method for intercell handover (PwrOptCtrl_16) .............4-533
4.24.6 DownLink optimize method for intercell handover (PwrOptCtrl_20) .........4-534
4.24.7 Uplink target level (UlTargetLevel) ........................................................4-535
4.24.8 Downlink target level (DlTargetLevel) ....................................................4-536
4.24.9 Low RSSI threshold (LowRssiThs)........................................................4-537
4.24.10 High RSSI Threshold (HighRssiThs) ...................................................4-539
4.24.11 Ms power inherit threshold (MsPwrInheritThs) .....................................4-540
4.24.12 Power dynamic sharing (PwrDynShare) ..............................................4-541
4.24.13 Power reserved for present users (PwrPres) .......................................4-542
4.24.14 Power Adjusting Threshold (PwrAdjustThreshold)................................4-543
4.24.15 Power admitting threshold (PwrAdmitThreshold)..................................4-544
4.24.16 Power admitting threshold punishment (PwrAdmitThrldPunish).............4-546
4.24.17 Power admitting threshold punishment time (PwrAdmitPunishTime) ......4-547
4.24.18 Power adjustment methods priority 1 (PwrAdjPriority_0).......................4-548
4.24.19 Power adjustment methods priority2 (PwrAdjPriority_1) .......................4-549
4.24.20 Power adjustment methods priority3 (PwrAdjPriority_2) .......................4-550
4.24.21 Power adjustment methods priority4 (PwrAdjPriority_3) .......................4-551
4.24.22 Power adjustment methods priority5 (PwrAdjPriority_4) .......................4-552
4.24.23 Threshold for increase 8PSK power (Inc8PskPwrThs) .........................4-553
4.24.24 Hysteresis for increase 8PSK power (Inc8PskPwrHys).........................4-554
XXVII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.24.25 Delay for increase 8PSK power (Inc8PskPwrDelay).............................4-555


4.25 GPRS Resource Control By Service ...............................................................4-556
4.25.1 Threshold of PS resource congestion (PSResourceThr0).......................4-556
4.25.2 Threshold of relieving PS resource congestion (PSResourceThr1) .........4-558
4.25.3 Scheduled priority of gold user's own service (SchedulePriority0) ...........4-559
4.25.4 Scheduled priority of silver user's own service (SchedulePriority1)..........4-560
4.25.5 Scheduled priority of bronze user's own service (SchedulePriority2) .......4-561
4.25.6 Scheduled priority of gold user's browse service (SchedulePriority3).......4-562
4.25.7 Scheduled priority of silver user's browse service (SchedulePriority4) ......4-563
4.25.8 Scheduled priority of bronze user's browse service
(SchedulePriority5) ..............................................................................4-564
4.25.9 Scheduled priority of gold user's download service
(SchedulePriority6) ..............................................................................4-565
4.25.10 Scheduled priority of silver user's download service
(SchedulePriority7) ..............................................................................4-566
4.25.11 Scheduled priority of bronze user's download service
(SchedulePriority8) ..............................................................................4-567
4.25.12 Scheduled priority of gold user's IM service (SchedulePriority9)............4-568
4.25.13 Scheduled priority of silver user's IM service (SchedulePriority10) ........4-569
4.25.14 Scheduled priority of bronze user's IM service (SchedulePriority11) ......4-570
4.25.15 TBF occupancy of gold user's own service (TBFNum0)........................4-571
4.25.16 TBF occupancy of silver user's own service (TBFNum1) ......................4-572
4.25.17 TBF occupancy of bronze user's own service (TBFNum2) ....................4-573
4.25.18 TBF occupancy of gold user's browse service (TBFNum3) ...................4-574
4.25.19 TBF occupancy of silver user's browse service (TBFNum4)..................4-575
4.25.20 TBF occupancy of bronze user's browse service (TBFNum5) ...............4-576
4.25.21 TBF occupancy of gold user's download service (TBFNum6)................4-577
4.25.22 TBF occupancy of silver user's download service (TBFNum7) ..............4-578
4.25.23 TBF occupancy of bronze user's download service (TBFNum8)............4-579
4.25.24 TBF occupancy of gold user's IM service (TBFNum9) ..........................4-580
4.25.25 TBF occupancy of silver user's IM service (TBFNum10).......................4-581
4.25.26 TBF occupancy of bronze user's IM service (TBFNum11).....................4-582
4.25.27 Max PDTCH num of gold user's own service in congestion
(MaxPdtchNum0) .................................................................................4-583
4.25.28 Max PDTCH num of silver user's own service in congestion
(MaxPdtchNum1) .................................................................................4-584
4.25.29 Max PDTCH num of bronze user's own service in congestion
(MaxPdtchNum2) .................................................................................4-585

XXVIII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.25.30 Max PDTCH num of gold user's browse service in congestion


(MaxPdtchNum3) .................................................................................4-586
4.25.31 Max PDTCH num of silver user's browse service in congestion
(MaxPdtchNum4) .................................................................................4-587
4.25.32 Max PDTCH num of bronze user's browse service in congestion
(MaxPdtchNum5) .................................................................................4-588
4.25.33 Max PDTCH num of gold user's download service in congestion
(MaxPdtchNum6) .................................................................................4-589
4.25.34 Max PDTCH num of silver user's download service in congestion
(MaxPdtchNum7) .................................................................................4-590
4.25.35 Max PDTCH num of bronze user's download service in congestion
(MaxPdtchNum8) .................................................................................4-591
4.25.36 Max PDTCH num of gold user's IM service in congestion
(MaxPdtchNum9) .................................................................................4-592
4.25.37 Max PDTCH num of silver user's IM service in congestion
(MaxPdtchNum10) ...............................................................................4-593
4.25.38 Max PDTCH num of bronze user's IM service in congestion
(MaxPdtchNum11) ...............................................................................4-594
4.25.39 Downlink delay time of gold user's own service
(DlDelayTimeOfService0) .....................................................................4-595
4.25.40 Downlink delay time of silver user's own service
(DlDelayTimeOfService1) .....................................................................4-596
4.25.41 Downlink delay time of bronze user's own service
(DlDelayTimeOfService2) .....................................................................4-597
4.25.42 Downlink delay time of gold user's browse service
(DlDelayTimeOfService3) .....................................................................4-598
4.25.43 Downlink delay time of silver user's browse service
(DlDelayTimeOfService4) .....................................................................4-599
4.25.44 Downlink delay time of bronze user's browse service
(DlDelayTimeOfService5) .....................................................................4-600
4.25.45 Downlink delay time of gold user's download service
(DlDelayTimeOfService6) .....................................................................4-601
4.25.46 Downlink delay time of silver user's download service
(DlDelayTimeOfService7) .....................................................................4-602
4.25.47 Downlink delay time of bronze user's download service
(DlDelayTimeOfService8) .....................................................................4-603
4.25.48 Downlink delay time of gold user's IM service
(DlDelayTimeOfService9) .....................................................................4-604
4.25.49 Downlink delay time of silver user's IM service
(DlDelayTimeOfService10) ...................................................................4-605

XXIX
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

4.25.50 Downlink delay time of bronze user's IM service


(DlDelayTimeOfService11)....................................................................4-606
4.25.51 Preemption priority of gold user's own service (PreemptPriority0) .........4-607
4.25.52 Preemption priority of silver user's own service (PreemptPriority1)........4-608
4.25.53 Preemption priority of bronze user's own service (PreemptPriority2) ......4-609
4.25.54 Preemption priority of gold user's browse service (PreemptPriority3) ......4-610
4.25.55 Preemption priority of silver user's browse service
(PreemptPriority4)................................................................................ 4-611
4.25.56 Preemption priority of bronze user's browse service
(PreemptPriority5)................................................................................4-612
4.25.57 Preemption priority of gold user's download service
(PreemptPriority6)................................................................................4-613
4.25.58 Preemption priority of silver user's download service
(PreemptPriority7)................................................................................4-614
4.25.59 Preemption priority of bronze user's download service
(PreemptPriority8)................................................................................4-615
4.25.60 Preemption priority of gold user's IM service (PreemptPriority9)............4-616
4.25.61 Preemption priority of silver user's IM service (PreemptPriority10) ........4-617
4.25.62 Preemption priority of bronze user's IM service (PreemptPriority11) ......4-618

Chapter 5 Cell Object Parameters............................................................. 5-1


5.1 TRX Parameters ................................................................................................ 5-1
5.1.1 TRX Information Parameters..................................................................... 5-1
5.1.2 Channel Information Parameters ............................................................. 5-17
5.1.3 IP Parameters........................................................................................ 5-33
5.1.4 Panel Parameters .................................................................................. 5-36
5.2 Power Control Parameters ................................................................................ 5-41
5.2.1 Power Control Parameters ...................................................................... 5-41
5.2.2 Power Survey Parameters ...................................................................... 5-47
5.2.3 Power Adjustment Threshold Parameters ................................................ 5-57
5.2.4 Other Parameters................................................................................... 5-76
5.2.5 New Power Control Attribute .................................................................. 5-110
5.2.6 GPRS Power Control Parameters ..........................................................5-137
5.3 Handover Control Parameters ..........................................................................5-214
5.3.1 Handover Pretreatment Parameters .......................................................5-215
5.3.2 Handover Level Parameters...................................................................5-233
5.3.3 Handover Condition Parameters.............................................................5-289
5.3.4 Handover Control Parameters ................................................................5-317
5.3.5 Other Parameters..................................................................................5-392

XXX
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

5.3.6 Handover Arithmetic Parameters............................................................5-420


5.3.7 Subcell Parameters ...............................................................................5-440
5.3.8 Weight Average Parameters ..................................................................5-457
5.4 SDCCH Handover Control Parameters .............................................................5-459
5.4.1 Handover Pretreatment Parameters .......................................................5-460
5.4.2 Handover Threshold Parameters............................................................5-473
5.4.3 Handover Condition Parameters.............................................................5-491
5.4.4 Handover Control Parameters ................................................................5-498
5.5 UTRAN Handover Control Parameters .............................................................5-533
5.5.1 Basic Properties 1 .................................................................................5-533
5.5.2 Basic Properties 2 .................................................................................5-553
5.5.3 PS Handover Parameters ......................................................................5-565
5.6 UTRAN Cell Control Parameters ......................................................................5-582
5.6.1 Basic Parameters 1 ...............................................................................5-582
5.6.2 Basic Parameters 2 ...............................................................................5-602
5.6.3 GPRS Parameters 1..............................................................................5-621
5.6.4 GPRS Parameters 2..............................................................................5-641
5.7 Adjacent Cell Parameters ................................................................................5-663
5.7.1 Adjacent Interference Cell Parameters....................................................5-663
5.7.2 Adjacent Cell Handover and Reselection Parameters ..............................5-667
5.7.3 Adjacent Cell Handover Parameters .......................................................5-717
5.7.4 Adjacent Cell Reselection Parameters ....................................................5-759
5.7.5 UTRAN Adjacent Cell Handover and Reselection Parameters..................5-767
5.7.6 UTRAN Adjacent Cell Handover Parameters...........................................5-784
5.7.7 UTRAN Adjacent Cell Reselection Parameters........................................5-797
5.8 Frequency Hopping System Parameters ...........................................................5-805
5.8.1 Site ID ..................................................................................................5-805
5.8.2 BTS ID (BtsId).......................................................................................5-806
5.8.3 Frequency hopping ID (FhsId) ................................................................5-807
5.8.4 Hopping sequence No. (HSN)................................................................5-808
5.8.5 Frequency hopping mode (FreqHopMode) ..............................................5-809
5.8.6 Hopping group ID (BhGroupId)...............................................................5-810
5.8.7 MA Frequency List Number (MaFreqNum) .............................................. 5-811
5.9 PS Handover Control Parameters ....................................................................5-812
5.9.1 Handover Pretreatment Parameters .......................................................5-812
5.9.2 Handover Level Parameters...................................................................5-823
5.9.3 Handover Condition Parameters.............................................................5-855

XXXI
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

5.9.4 Handover Control Parameters ................................................................5-865


5.9.5 Other Parameters..................................................................................5-872
5.9.6 Handover Arithmetic Parameters............................................................5-878
5.10 LTE Cell Control Parameters ..........................................................................5-888
5.10.1 Site Id (SiteId) .....................................................................................5-888
5.10.2 BTS ID (BtsId).....................................................................................5-889
5.10.3 EUTRAN BTS ID (LTEBTSID) ..............................................................5-890
5.10.4 QSearchC (QSearchC) ........................................................................5-891
5.10.5 Initial parameter used before UE receiving qsearch_c (QSearchCInit) ......5-892
5.10.6 Class of reported quantities of E-UTRAN adjacent cells (RepQuant).......5-893
5.10.7 Max number of E-UTRAN adjacent cells in measurement report
(MulRatRrpt)........................................................................................5-894
5.10.8 FDD Measurement report threshold of RSRP or RSRQ in 6-bit
(FDDRptthresh) ...................................................................................5-895
5.10.9 FDD Measurement report threshold of RSRQ or RSRP in 6-bit reporting
(FDDRptthresh2) .................................................................................5-896
5.10.10 FDDRptOffset6bit (FDDRptOffset6bit).................................................5-897
5.10.11 FDDRptOffset3bit (FDDRptOffset3bit) .................................................5-898
5.10.12 TDD Measurement report threshold of RSRP or RSRQ in 6-bit
reporting (TDDRptthresh) .....................................................................5-899
5.10.13 TDD Measurement report threshold of RSRQ or RSRP in 6-bit
reporting (TDDRptthresh2) ...................................................................5-900
5.10.14 TDDRptOffset6bit (TDDRptOffset6bit).................................................5-901
5.10.15 TDDRptOffset3bit (TDDRptOffset3bit).................................................5-902
5.10.16 FDD Measurement report threshold of RSRP or RSRQ in 3-bit
reporting (FDDMeasRptOffset) .............................................................5-903
5.10.17 FDD Measurement report threshold of RSRQ or RSRP in 3-bit
reporting (FDDMeasRptthresh2) ...........................................................5-904
5.10.18 TDD Measurement report threshold of RSRP or RSRQ in 3-bit
reporting (TDDMeasRptOffset) .............................................................5-905
5.10.19 TDD Measurement report threshold of RSRQ or RSRP in 3-bit
reporting (TDDMeasRptthresh2) ...........................................................5-906
5.10.20 Measurement report threshold offset of RSRQ or RSRP in 3-bit
reporting (RptGranularity) .....................................................................5-907
5.10.21 Measurement threshold of UE performing GPRS E-UTRAN Cell
(QsearchP_PS) ...................................................................................5-908
5.10.22 GPRS max number of E-UTRAN adjacent cells in measurement report
(MulRatRpt_PS)...................................................................................5-909
5.10.23 GPRS class of reported quantities of E-UTRAN adjacent cells
(RepQuant_PS) ...................................................................................5-910
XXXII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

5.10.24 GPRS FDD Measurement report threshold of RSRP or RSRQ


(FDDRptThresh_PS) ............................................................................ 5-911
5.10.25 GPRS FDD Measurement report threshold of RSRQ or RSRP
(FDDRptThresh2_PS) ..........................................................................5-912
5.10.26 FDDRptOffset_PS (FDDRptOffset_PS) ...............................................5-912
5.10.27 GPRS TDD Measurement report threshold of RSRP or RSRQ
(TDDRptThresh_PS) ............................................................................5-913
5.10.28 GPRS TDD Measurement report threshold of RSRQ or RSRP
(TDDRptThresh2_PS) ..........................................................................5-914
5.10.29 TDDRptOffset_PS (TDDRptOffset_PS) ...............................................5-915
5.10.30 WindowEutran (WindowEutran) ..........................................................5-916
5.11 LTE Cell Reselection Parameters ...................................................................5-917
5.11.1 User label (UserLabel) .........................................................................5-917
5.11.2 SITE ID (SITEID) .................................................................................5-918
5.11.3 BTS ID (BTSID)...................................................................................5-919
5.11.4 LTE Cell reselect Identification (LTERSID).............................................5-920
5.11.5 The priority of E-UTRAN cells (ArfcnLTEPrio) ........................................5-921
5.11.6 CCN mode support (CCNSUPPORT)....................................................5-922
5.11.7 The re-selecting flag of LTE Ncell (NCelBlackListInd) .............................5-923
5.11.8 MCC (MCC) ........................................................................................5-924
5.11.9 MNC (MNC) ........................................................................................5-925
5.11.10 LTE CELL Identification (ENBID).........................................................5-926
5.11.11 LTE CELL TYPE (CellTypeLTE) ..........................................................5-927
5.11.12 Tracking area code (TAC)...................................................................5-927
5.11.13 Physical layer cell identity of LTE CELL (PCID)....................................5-928
5.11.14 The attribute of LTE NodeB (ENBInd)..................................................5-929
5.11.15 Specified EARFCN of E-UTRAN cells (ArfcnLTE) ................................5-930
5.11.16 the minimum value of the channel bandwidth (MeasureBandwidth) .......5-931
5.11.17 Related Cell DN (RelationDN).............................................................5-932
5.12 VPC Cell Parameters.....................................................................................5-933
5.12.1 User label (UserLabel) .........................................................................5-933
5.12.2 Site identifier (SiteId) ...........................................................................5-934
5.12.3 BTS ID (BtsId).....................................................................................5-935
5.12.4 Vpc Identity (VpcId) .............................................................................5-936
5.12.5 Vpc Site Identity (VpcSiteId).................................................................5-937
5.12.6 Vpc Bts Identity (VpcBtsId)...................................................................5-938
5.13 Site Parameters ............................................................................................5-939
5.13.1 Inter subcell handover permitted (SUBCELLHO) ...................................5-939
XXXIII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

5.13.2 Baseband resource share support (BaseBandShare).............................5-940


5.13.3 Traffic threshold for baseband allocation (BBURequestTRAThs).............5-941
5.13.4 Traffic threshold for baseband release (BBUReleaseTRAThs) ................5-942
5.13.5 Channel busy threshold for urgent allocate baseband
(BBUOVERThs)...................................................................................5-943
5.13.6 Channel busy threshold for urgent release baseband
(BBULOWERThs) ................................................................................5-944

Chapter 6 System Control Parameters..................................................... 6-1


6.1 Operation Control Parameters............................................................................. 6-1
6.1.1 User Label ............................................................................................... 6-1
6.1.2 BSC ID .................................................................................................... 6-2
6.1.3 Assign queue enable (AssQueEnable)....................................................... 6-3
6.1.4 Internal redirection enable (InDrEnable)..................................................... 6-4
6.1.5 Outer redirection enable (OutDrEnable) ..................................................... 6-5
6.1.6 Assign preemption enable (AssPreEmpt) ................................................... 6-6
6.1.7 BSC intracell handover enable (HoIntraEnable).......................................... 6-7
6.1.8 BSC cell handover enable (HoInterEnable) ................................................ 6-8
6.1.9 BSC outer handover enable (HoOutEnable)............................................... 6-9
6.1.10 SDCCH handover enable (ShoEnable) .................................................. 6-10
6.1.11 TCH/F handover enable (TfHoEnable) ....................................................6-11
6.1.12 TCH/H handover enable (ThHoEnable).................................................. 6-12
6.1.13 Handover queue enable (HoQueEnable)................................................ 6-13
6.1.14 Handover preemption enable (HoPreEmpt) ............................................ 6-14
6.1.15 Handover check arithmetic choose (HoA)............................................... 6-15
6.1.16 Handover request response (HoAck) ..................................................... 6-16
6.1.17 Force FACCH (FacchOnly) ................................................................... 6-17
6.1.18 Continuous handover trigger (HoTrigger) ............................................... 6-18
6.1.19 Handover reason tip (HoCauseInd)........................................................ 6-19
6.1.20 Local cell position number (LAC) ........................................................... 6-20
6.1.21 Local cell identity (CI) ........................................................................... 6-21
6.1.22 Outer cell target number (OutCellNum) .................................................. 6-22
6.1.23 Outer cell position number 1 (OutLAC1)................................................. 6-23
6.1.24 Outer cell position number 2 (OutLAC2)................................................. 6-24
6.1.25 Outer cell position number 3 (OutLAC3)................................................. 6-25
6.1.26 Outer cell number 1 (OutCI1) ................................................................ 6-25
6.1.27 Outer cell number 2 (OutCI2) ................................................................ 6-26
6.1.28 Outer cell number 3 (OutCI3) ................................................................ 6-27
6.1.29 Outer RNC 1 (OutRNC1) ...................................................................... 6-28
XXXIV
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

6.1.30 Outer RNC 2 (OutRNC2) ...................................................................... 6-29


6.1.31 Outer RNC 3 (OutRNC3) ...................................................................... 6-30
6.1.32 Old BSS to new BSS information (OldToNewctrl).................................... 6-31
6.1.33 BSC Internal Handover Parameter of IPA (IPAInterHo)............................ 6-32
6.1.34 Send suspend message when GPRS suspension (ResumeSetOpt)......... 6-34
6.1.35 Queuing indicator in handover required message (HandOutQueInd)........ 6-35
6.1.36 Send cell prefer indication (SendCellPreferInd)....................................... 6-36
6.1.37 IPA AMR start mode (IpaAMRStartMode)............................................... 6-37
6.1.38 TDD cell handover enable (TdHoEnable) ............................................... 6-38
6.1.39 ICM optimize when intra BSC handover (AmrHoOpt_0) .......................... 6-39
6.1.40 ICM optimize when inter BSC handover (AmrHoOpt_1) .......................... 6-40
6.1.41 The switch of connection and radio channel activating synchronization
(CallDelayCtrl) ...................................................................................... 6-41
6.1.42 Include trace ID in handover required (HoRqdCtrl_0) .............................. 6-42
6.1.43 Inter BSC handover out on SDCCH permitted (InterBSCSDHOout) ......... 6-43
6.1.44 Use BER to average quality (RQAvgUseBER)........................................ 6-44
6.1.45 Check IMSI when access (CheckIMSIWhenAccess) ............................... 6-45
6.1.46 Allow assign according first measurement report when use cobcch
(CoBcchAssByOneMr) .......................................................................... 6-46
6.1.47 Use N/P when select neighbour cell for Pbgt handover in Sdcch
(NcellSelCtrlPbgt1) ............................................................................... 6-48
6.1.48 Use N/P when select neighbour cell for Pbgt handover in Tch
(NcellSelCtrlPbgt2) ............................................................................... 6-49
6.1.49 Use N/P when select neighbour cell for uplink quality handover in Sdcch
(NcellSelCtrlUlQ1)................................................................................. 6-50
6.1.50 Use N/P when select neighbour cell for uplink quality handover in Tch
(NcellSelCtrlUlQ2)................................................................................. 6-51
6.1.51 Use N/P when select neighbour cell for downlink quality handover in
Sdcch (NcellSelCtrlDlQ1) ...................................................................... 6-52
6.1.52 Use N/P when select neighbour cell for downlink quality handover in
Tch (NcellSelCtrlDlQ2) .......................................................................... 6-53
6.1.53 Use N/P when select neighbour cell for uplink level handover in Sdcch
(NcellSelCtrlUlLev1).............................................................................. 6-54
6.1.54 Use N/P when select neighbour cell for uplink level handover in Tch
(NcellSelCtrlUlLev2).............................................................................. 6-55
6.1.55 Use N/P when select neighbour cell for downlink level handover in
Sdcch (NcellSelCtrlDlLev1).................................................................... 6-56
6.1.56 Use N/P when select neighbour cell for downlink level handover in Tch
(NcellSelCtrlDlLev2).............................................................................. 6-57

XXXV
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

6.1.57 Use Subcell 1 as Cell Load (UseSC1Load) ............................................ 6-58


6.1.58 MS Report Count for Rlt (MrCountForRlt)............................................... 6-58
6.1.59 BSC intracell handover enable for circuit switch data
(CSDHoIntraEnable) ............................................................................. 6-59
6.1.60 BSC cell handover enable for circuit switch data (CSDHoInterEnable) ..... 6-60
6.1.61 BSC outer handover enable for circuit switch data (CSDHoOutEnable) ..... 6-61
6.2 FUC Parameters .............................................................................................. 6-62
6.2.1 Use system message method when MSC over loaded or link blocked
(MSCSysInfoFlc)................................................................................... 6-62
6.2.2 Start system message method (CPUSysInfoFlc) ...................................... 6-63
6.2.3 Start limit of system message method (CPUSysInfoCTLCPU) ................... 6-64
6.2.4 Start FUC flow control (CPUFucFlc) ........................................................ 6-65
6.2.5 Start limit of FUC flow control (CPUFucCtlCPU) ....................................... 6-66
6.2.6 If paging flow control due to high CPU (CpuPagingFlc) ............................. 6-67
6.2.7 CPU threshold of paging flow control (CpuPagingCtlCpu) ......................... 6-68
6.2.8 The maximum control level for MSC overload or link block
(MSCFlcMaxLevel) ............................................................................... 6-69
6.2.9 The number of channel requests permitted per second (ChlReqNum)........ 6-70
6.2.10 The number of paging messages permitted per second (PagingNum)...... 6-71
6.3 Exchange Parameters of BCCH ........................................................................ 6-72
6.3.1 BCCH switch (CanBCCHEx) ................................................................... 6-72
6.3.2 Scan BCCH (ScanBCCH) ....................................................................... 6-73
6.3.3 BCCH starting delay (BCCHDelay).......................................................... 6-74
6.3.4 BCCH finishing delay (ReBcchEx) ........................................................... 6-75
6.3.5 Delay of TRX forcible release (TrxRel) ..................................................... 6-76
6.3.6 The maximum cells' amount of simultaneously handover
(MaxChangeProc)................................................................................. 6-78
6.3.7 Cell Break Alarm Delay (CellAlarmDelay)................................................. 6-79
6.4 Exchange Parameters of SD ............................................................................. 6-80
6.4.1 Dynamic configuration SDCCH (CanSDCCHDyn) .................................... 6-80
6.4.2 Scan SDCCH (ScanSDCCH) .................................................................. 6-81
6.4.3 Delay of TS forcible release (TsRel)......................................................... 6-82
6.4.4 Delay protection (MaxDelay) ................................................................... 6-83
6.4.5 TCH->SDCCH limit (MinSDCCH) ............................................................ 6-84
6.4.6 SDCCH->TCH delay (TimeToTch) ........................................................... 6-85
6.4.7 Dynamic SDCCH Channel Check Delay (DynSdCheckDelay) ................... 6-86
6.5 Other Parameters............................................................................................. 6-87
6.5.1 B2 support AMR (V2TruSupportAMR) ..................................................... 6-87
XXXVI
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

6.5.2 NC2 support (NC2support) ..................................................................... 6-88


6.5.3 MR server IP (MRSvrIP) ......................................................................... 6-89
6.5.4 MR server port (MRSvrPort).................................................................... 6-90
6.5.5 Include BTS power in MR (MrIncludeBtsPwr) ........................................... 6-90
6.5.6 Enhanced and Preprocessde MR report (EnhanAndPrepMrRpt)................ 6-91
6.5.7 Power congest delay (PwrCongDelay)..................................................... 6-92
6.5.8 Enable power dynamic sharing (PwrDynShareSupport_0) ........................ 6-93
6.5.9 Reduction of TCH initial downlink power according to SDCCH enable
(PwrDynShareSupport_1)...................................................................... 6-94
6.5.10 Channel power adjustment based on power dynamic sharing enable
(PwrDynShareSupport_2)...................................................................... 6-95
6.5.11 Time interval of channel power adjustment based on power dynamic
sharing (ChannelPwrAdjItvl)................................................................... 6-96
6.5.12 Ts Block Alarm Swtich (TsBlockAlarmSwitch) ......................................... 6-97
6.5.13 BER Weight (VoiceQualWeight_0)......................................................... 6-98
6.5.14 FER Weight (VoiceQualWeight_1) ......................................................... 6-99
6.5.15 Handover frequence weight (VoiceQualWeight_2) .................................6-100
6.5.16 DTX weight (VoiceQualWeight_3).........................................................6-101
6.5.17 Coding decode weight (VoiceQualWeight_4) .........................................6-102
6.5.18 Abis transmission error code weight (VoiceQualWeight_5) .....................6-103
6.5.19 Delay weight (VoiceQualWeight_6).......................................................6-104
6.5.20 A port resource block threshold (Reslimit_0) .........................................6-105
6.5.21 NSVC resource block threshold (Reslimit_1) .........................................6-106
6.5.22 Channel resource block threshold (Reslimit_2) ......................................6-106
6.5.23 Subcell busy threshold (Reslimit_3) ......................................................6-107
6.5.24 Abis alarm delay time (AbisAlmDelayTime) ...........................................6-108
6.5.25 DTX factor (Info_0_8) ..........................................................................6-109
6.5.26 CS traffic threshold of slave to master (SToMTrafficThrs_0).................... 6-110
6.5.27 PS traffic threshold of slave to master (SToMTrafficThrs_1).................... 6-111
6.5.28 Baseband resource share support (BaseBandShare)............................. 6-113
6.5.29 TRX Selection priority for baseband share (BBSharePri)........................ 6-113
6.5.30 Close back up (CloseBackUp).............................................................. 6-114
6.5.31 Auto slave to master enable (AutoSToMEnable) .................................... 6-115
6.5.32 CIC Manual Block Alarm (CICAlarmSwitch)........................................... 6-116
6.5.33 BVC Manual Block Alarm (BVCAlarmSwitch) ........................................ 6-117
6.5.34 Slave to master time bitmap (SToMTimeBitMap).................................... 6-118
6.5.35 Measurement Result Recording Interval in MSC Invoke Trace
(MITMRRecInt) .................................................................................... 6-119
XXXVII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

6.5.36 Preprocessed Measurement Result Recording Interval in MSC Invoke


Trace (MITPrepMRRecInt).................................................................... 6-119
6.6 IBS Parameters............................................................................................... 6-119
6.6.1 The method of intelligent TRX poweroff (Info_0_0) .................................. 6-119
6.7 Performance Management Parameters.............................................................6-120
6.7.1 Pingpong handover duration (PingPongDura) .........................................6-120
6.7.2 Number of measurement reports for dropped connections
(LatestMeasureRptNum) ......................................................................6-122
6.7.3 Uplink quality threshold (DropBadQualULThs).........................................6-123
6.7.4 Downlink quality threshold (DropBadQualDLThs) ....................................6-124
6.7.5 Uplink signal strength threshold (DropLowSigStrULThs) ..........................6-125
6.7.6 Downlink signal strength threshold (DropLowSigStrDLThs) ......................6-126
6.7.7 Excessive TA threshold (DropExcessiveTAThs).......................................6-127
6.8 Baseband Frequency Hopping TRX Exchange Parameters................................6-128
6.8.1 Baseband frequency hopping TRX exchange support (Info_0_1)..............6-128
6.8.2 Baseband frequency hopping TRX exchange scan timer (Info_1_0) .........6-129
6.8.3 Baseband frequency hopping TRX configuration timer (Info_1_16) ...........6-130
6.8.4 Baseband frequency hopping TRX exchange check delay timer
(Info_2_0)............................................................................................6-132
6.9 GPRS Operation Control Parameters ...............................................................6-133
6.9.1 Two-phase access (TwoPhaseAccess) ...................................................6-133
6.9.2 Send radio status to SGSN (GBMsgSndInd_0)........................................6-134
6.9.3 Send LLC discard to SGSN (GBMsgSndInd_1) .......................................6-135
6.9.4 Threshold of quality in radio status (RadStaQuaThs) ...............................6-136
6.9.5 Send packet TBF release to MS when BSS abnormal (PacketTBFRel) ......6-137
6.9.6 Initial retry interval in downlink buffer state (DwBufRetryInterval) ..............6-138
6.9.7 Retry number in downlink buffer state (DwBufRetryNum) .........................6-139

Appendix A Flow Control Policy Values.................................................. A-1


Appendix B Power Values ........................................................................ B-1
Appendix C Setting of Cell Layers........................................................... C-1
Appendix D Relationship between Parameter Interface and
Database Value...................................................................................... D-1
D.1 BSC Function Parameters Interface ....................................................................D-1
D.1.1 Basic Property Parameters.......................................................................D-1
D.1.2 Radio Basic Property Parameters .............................................................D-4
D.1.3 Other Parameters ....................................................................................D-4
D.1.4 AMR Half Method Parameters ..................................................................D-5

XXXVIII
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

D.1.5 AMR Full Method Parameters...................................................................D-6


D.1.6 GPRS Property 1 Parameters...................................................................D-7
D.1.7 GPRS Property 2 Parameters...................................................................D-7
D.1.8 EDGE Parameters ...................................................................................D-8
D.2 GERAN External Cell Parameters.......................................................................D-8
D.3 UTRAN External Cell Parameters .......................................................................D-9
D.4 Cell Parameters.................................................................................................D-9
D.4.1 Basic Parameters 1 .................................................................................D-9
D.4.2 Basic Parameters 2 ............................................................................... D-10
D.4.3 Other Parameters .................................................................................. D-10
D.4.4 System Parameters ............................................................................... D-11
D.4.5 GPRS Other Parameters 1 ..................................................................... D-11
D.4.6 GPRS Cell Options Parameters .............................................................. D-11
D.4.7 GPRS NC Survey Parameters ................................................................ D-14
D.4.8 GPRS Power Control Parameters ........................................................... D-15
D.4.9 GPRS Cell Reselection Parameters ........................................................ D-16
D.4.10 GPRS Channel Parameters.................................................................. D-17
D.4.11 EDGE Parameters ............................................................................... D-19
D.5 Cell Object Parameters Interface ...................................................................... D-19
D.5.1 TRX Info Parameters ............................................................................. D-19
D.5.2 Channel Info Parameters........................................................................ D-20
D.5.3 Power Control Parameters ..................................................................... D-21
D.5.4 Handover Control Parameters ................................................................ D-22
D.5.5 UTRAN Cell Control Parameters............................................................. D-23
D.5.6 UTRAN Handover Control Parameters .................................................... D-25
D.5.7 Adjacent Cell Handover and Reselection Parameters............................... D-25
D.5.8 Adjacent Cell Handover Parameters ....................................................... D-25
D.5.9 Frequency Hopping System Parameters ................................................. D-26

Appendix E Mutex Right Management .....................................................E-1


E.1 Applying for the Mutex Right ............................................................................... E-1
E.2 Releasing the Mutex Right.................................................................................. E-1

Figures............................................................................................................. I
Tables ............................................................................................................ III
Glossary .........................................................................................................V

XXXIX
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

XL
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

About This Manual


About this Manual
This manual introduces the ZXG10 iBSC radio parameters for radio configuration and
commissioning.

Audience
l
l
l

System Engineer
Commissioning Engineer
Maintenance Engineer

What Is in This Manual


This manual has the following chapters.
Chapter Name

Summary

Chapter 1 Overview

Introduces the scope, description methods, and adjustment cautions


for radio parameters.

Chapter 2 BSC Function

Introduces the BSC function parameters.

Parameters
Chapter 3, External Cell

Introduces the GERAN external cell parameters and UTRAN external

Parameters

cell parameters.

Chapter 4, Cell Parameters

Introduces the cell parameters in the BSS system.

Chapter 5, Cell Object

Introduces the cell object parameters in the BSS system.

Parameters
Chapter 6, System Control

Introduces the system control parameters in the BSS system.

Parameters
Appendix A, Flow Control

Introduces the data values of Flow Control Policy.

Policy Values
Appendix B, Power Values

Introduces the data values of Power

Appendix C, Setting of Cell

Introduces the setting of Cell Layers

Layers
Appendix D, Corresponding

Introduces the relationship between radio parameters on the interface

Relationship between

and database values in the BSS system.

Parameter Interface and


Database Values
Appendix E, Mutex Right

Introduces how to apply or release the mutex right.

Management

I
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

II
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 1

Overview
This chapter explains the definition and classification of radio parameters in GSM network,
modification methods of radio parameters, explanation format of radio parameters, and
precautions in radio parameters adjustment.

Table of Contents
Introduction to BSS Radio Parameters .......................................................................1-1
Modify Parameters .....................................................................................................1-2
Method of Modifying Parameters in Batch ..................................................................1-4
The Format to Explain Parameters .............................................................................1-9
Precautions on Parameter Adjustment .....................................................................1-11

1.1 Introduction to BSS Radio Parameters


Radio parameters in GSM network refer to parameters related to radio devices and radio
resources. These parameters have an important impact on coverage of cells, distribution of
signaling flow and service property of network, etc. Therefore, adjusting radio parameters
reasonably plays a very important part in GSM network optimization.
GSM radio parameters are classified into project parameters and resource (cell)
parameters.
1. Project parameters
Project parameters refer to parameters related to design, installation, and
commissioning of the project, like antenna height, antenna direction, antenna
gain, antenna download obliquity and cable loss, etc. These parameters must be
determined during network design and are seldom changed during the operation of
the network.
2. Resource (cell) parameters
Resource (cell) parameters refer to parameters related to configuration and utilization
of radio resources, which usually transmit on radio interface (Um) to keep the base
station and mobile station consistent. Radio parameters covered in this manual are
mainly resource parameters. Radio resource parameters in BSS contain:
l
l
l

GERAN subnetwork parameters, BSC management NE parameters,


configuration set parameters;
Global resource parameters for BSC, site parameters, GERAN external cell
parameters, UTRAN external cell parameters;
Cell Parameters;

1-1
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

TRX parameters, power control parameters, handover control parameters,


UTRAN handover control parameters, adjacent interference cell parameters,
adjacent handover cell parameters, adjacent reselection cell parameters,
adjacent handover and reselection cell parameters, UTRAN adjacent cell
handover and reselection parameters, UTRAN adjacent handover cell
parameters, UTRAN adjacent reselection cell parameters, frequency hopping
system parameters.

1.2 Modify Parameters


This section describes how to modify parameters in NetNumen.

Prerequisite
The mutex right have been applied.

Note:
The description of mutex right apply please refer to the Appendix E Mutex Right
Management in this manual.

Steps
1. In the left topology tree of NetNumen U31 main interface, right-click the shortcut menu
corresponding to the created GSM NE agent, select Start.
2. Right-click the started GSM NE and select Start, as shown in Figure 1-1.

1-2
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 1 Overview

Figure 1-1 Starting NE Agent

3. After the NE is started, in the left topology tree of NetNumen U31 main interface,
right-click shortcut menu corresponding to created GSM NE agent, select NE Agent
Management > Configuration Management, the Configuration Management tab
is displayed, as shown in Figure 1-2.

1-3
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Figure 1-2 Configuration Management tab

The tree in the left pane shows the objects to be created and maintained. User
can double-click the node whose parameters shall be modified, the corresponding
parameter interface occurs in right window.
End of Steps

1.3 Method of Modifying Parameters in Batch


This section describes how to modify parameters in batch in NetNumen, after successfully
import the data, the modified parameters will be synchronized to NE.
After successfully logging in to NetNumen U31, perform the following steps to modify
parameters in batch.
1. In the configure resource tree window, right-click OMC > GERAN subnet user ID
> BSC Management Element ID > Config Set ID > BSC Function ID > Export
Configuration Data > Export Network Plan Data, as shown in Figure 1-3.

1-4
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 1 Overview

Figure 1-3 Selecting Export Network Plan Data

2. Click Export Network Plan Data, and the Choose MOC to be Exported dialog box
appears. Select the parameter list to be exported, and click Next, as shown in Figure
1-4.
Figure 1-4 Selecting MOC to Be Exported

3. In the Choose Attributes of Each MOC to be Exported (RDN Excluded) dialog box,
select attribute of the parameter list to be exported, and click OK. Here, suppose the
MOC selected is IBSCFUNCTION_TABLE, as shown in Figure 1-5.

1-5
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Figure 1-5 Selecting Attributes to Be Exported for MOC

4. Select the file type to be exported, and click OK. Here, suppose the data is exported
to be an Excel file, as shown in Figure 1-6.
Figure 1-6 Selecting File Type to Be Exported

5. Set the saving path and file name for the exported data, and click Save.
The data export progress bar is displayed, and then the system prompts that the data
is exported successfully.
6. Open the exported data file, as shown in Figure 1-7.
Figure 1-7 Parameter Data

7. Modify the data file according to actual requirement, and save it.
1-6
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 1 Overview

The operation indications are described as follows.


a. D indicates deleting the managed object (MO). A indicates adding the MO. M
indicates modifying the MO (this command is issued only when the parameter
value is changed). Any value beyond D, A, and M (including the lower case form)
will be ignored by the system, and the corresponding data in that row will not be
processed.
b. For the same MO (such as cell, cell power control and cell handover control),
if the operation type (D, A or M) appears in multiple exported tables, then the
operation types of all columns must be the same; otherwise, the system will give
error prompt.
c.

No matter how many records in the Excel table should be deleted, created or
modified, the system performs deletion first, then performs creation, and finally
performs modification.

Note:
The order of operations has nothing to do with the order of records being displayed
in the Excel file.

d.
l

If multiple objects among which reference relationship exists should


deleted, the system first deletes the active reference object (such
sub-object), and then deletes the passive reference object (such
parent-object).
If multiple objects among which reference relationship exists should
created, the system first creates the passive reference object (such
parent-object), and then creates the active reference object (such
sub-object).
If multiple objects among which reference relationship exists should
modified, the system first modifies the passive reference object (such
parent-object), and then modifies the active reference object (such
sub-object).

be
as
as
be
as
as
be
as
as

1-7
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Note:
The following lists the restriction conditions of Excel template:
l
l
l

l
l

The exported Excel file is the import template.


In the Excel template, the work sheet name cannot be modified.
In the Excel template, the title row in the work sheet cannot be modified, the
frozen column cannot be modified, and the cell type cannot be modified. However,
common data columns and data rows can be deleted.
The parameter that cannot be modified on the interface cannot be modified in the
batch modification.
In the Excel template, the attributes USERLABEL, MCC, MNC, LAC and CI
appear in multiple work sheets, but only the modification in the network parameter
list is valid.
The parameter MAIO of channels supporting baseband frequency hopping cannot
be modified.

8. In the configuration resource tree window, right-click OMC > GERAN Subnetwork ID
> BSC Managed Element ID > Config Set ID > BSC Function ID > Batch Apply
Network Plan Data, as shown in Figure 1-8.
Figure 1-8 Selecting Batch Apply Network Plan Data

9. Select the file type to be imported, and click OK, as shown in Figure 1-9.
1-8
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 1 Overview

Figure 1-9 Selecting File Type to Be Imported

10. In the Open dialog box, select the data file to be imported, and click Open.
11. In the Batch Network Plan Data Apply dialog box, select the object to which the data
is applied, and click OK, as shown in Figure 1-10.
Figure 1-10 Applying Network Planning Data in Batch

The progress bar is displayed, and then the system prompts that the instruction is
executed successfully.

Note:
If the number of successfully executed instructions is 0, it indicates that no data needs
to be modified. If the number is not 0, it indicates that the data in the file is inconsistent
with that at the server.

1.4 The Format to Explain Parameters


Each radio parameter in this manual is individually clarified in a table. For details, refer to
Table 1-1.

1-9
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Note:
1. Radio parameters in this system is modified through offline modification mode, that is,
the modification on interface only can be effective after the synchronization action to
NE is conducted.
2. Some parameter values in the interface are not fully the same as those in database,
with certain corresponding relationship between them. For specific corresponding
relationship, refer to appendixes.

Table 1-1 Format to Explain Radio Parameters


Full Name

English Parameter Name on the Interface

Abbreviation

Abbreviation for English parameters

3GPP Name

Parameter name in 3GPP protocol

3GPP Reference

3GPP protocol version number for parameter reference

Description

Descriptive text for this parameter

Managed Object

Involved object by the parameter

Value Range and

Value range and step of this parameter. If the parameter is in mapping form,

Step

actual parameter value that corresponds to all indices will be enumerated

Unit

Parameter unit

Default Value

English Parameter Name on the Interface

Default Value
Configuration Reason

The reason for setting the default value of this parameter


The factors that are taken into consideration during this parameter
configuration.

Configuration Rule

The impact on the network performance and users feeling after this

and Adjustment

parameter is adjusted to a larger or smaller value.

Suggestion

The parameter related to scenarios specifies the adjustment suggestion.


Online = After a parameters value is modified, it is immediately synchronized
and takes effect.
Offline = After one or several parameters' values are modified, the

Change Mode

modification takes effect after data synchronization.


Relevant functions and features of the network that correspond to this

Related Features

parameter
Parameters which have data restriction relationship with the parameter.
For example, this parameter takes effect only after one or multiple relevant
parameters are enabled; this parameter's value has a restriction relationship
with one or multiple relevant parameters, such as larger than or smaller than

Related Parameters

the relevant parameter.

1-10
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 1 Overview

Relationship

Dependency among relevant parameters

Related Interfaces

Interfaces related to this parameter


The impact on the equipment. after the modification of this parameter is
valid. The impact levels are described as follows:
Level 0: Modifying this parameter will bring an impact on the running of this
equipment. That is, during this parameter setting, the equipment is not
influenced.
Level 1: Modifying this parameter will cause the carrier deleted and
established, and the cell out of service.
Level 2: Modifying this parameter will cause the base station out of service.

Impact on Equipment

Level 3 : Modifying this parameter will cause BSC out of service.


The impact on the services ( such as, services are interrupted) after the
modification of this parameter is valid. The impact levels are described as
follows:
Level 0: Modifying this parameter will not bring an impact on the idle state
and connection state of the services, but not on the usage and status of all
users. That is, the users cannot detect the change of network service.
Level 1: Modifying this parameter will bring an impact on the users in idle
state, but not on the users during communication or network connection.
Level 2: Modifying this parameter will cause the communication and service
interrupted, but restored in a short while. For example, you can initiate a
service immediately.
Level 3: Modifying this parameter will bring an impact on all users in idle
and connection modes, and will cause the network service interrupted, and

Impact on service

restored for a period of time.

Negotiation With CN

Whether this parameter should be negotiated with CN

OMC Access Path

This parameters location on the network management interface

Parameter Modifying
Version

Whether this parameter is modified in this version

Parameter Modifying
Detail

Modification details of this parameter in this version

1.5 Precautions on Parameter Adjustment


Radio parameters adjustment, according to the type of the problem to be solved, falls into
two kinds.
l

First is to solve static problem, that is, to correct traffic model in system design by
measuring actual average traffic and signaling flow in every district and to solve
common problems existing for long.
Second is to solve problems at a particular time like traffic overload in some district,
channel congestion due to sudden events or random events.
1-11

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

For the first type, service providers must perform measurement and summarization on
actual operation regularly, and then perform appropriate adjustment on global or partial
parameters and configurations. For the second type, network operators adjust some radio
parameters at real time according to instant data from measurement results.
Most radio parameters in GSM system are based on one cell or one location area. It is
necessary to consider whether parameter adjustment in this cell will influence other cells,
especially the adjacent one, for parameters between cells are related to each other greatly.
Otherwise, it may cause negative influence.
Determine whether the problem results from equipment fault (including connections) first
when it occurs in some part of the network. Adjust radio parameters only when determined
that the problem does result from service.

1-12
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2

BSC Function Parameters


Table of Contents
Radio Basic Property..................................................................................................2-1
Functional Switch .....................................................................................................2-26
Other Parameters.....................................................................................................2-45
Channel Allocation Control Parameters ....................................................................2-78
Timer 1.....................................................................................................................2-90
Timer 2...................................................................................................................2-120
GPRS Maximum Retrying Times ............................................................................2-160
GPRS Timer...........................................................................................................2-175
AMR Half Method Parameters................................................................................2-206
AMR Full Method Parameters ................................................................................2-214
GPRS Other Parameters 1 .....................................................................................2-222
GPRS Other Parameters 2 .....................................................................................2-231
BVC Flow Control Parameters................................................................................2-252
FUC Flow Control Map Parameters ........................................................................2-264
EDGE Parameters..................................................................................................2-274
eMLPP Set Parameters..........................................................................................2-295
User Access Flow Control Parameters ...................................................................2-325
UPPB Resource Alarm Parameters........................................................................2-331
AMR-WB Parameter...............................................................................................2-340
Iur-g Parameter ......................................................................................................2-342
Ater Timer Parameters ...........................................................................................2-353

2.1 Radio Basic Property


2.1.1 DCS1800/PCS1900 support (FuncExt)
Full Name

DCS1800/PCS1900 support

Abbreviation

FuncExt

3GPP Name

None

3GPP Reference

None
This parameter indicates the supported frequency band. If you select
DCS1800, the DCS1800 frequency band will be supported. If you select
PCS1900, the PCS1900 frequency band will be supported. This param-

Description

eter cannot be modified after you select a frequency band.

2-1
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

BSC
DCS1800

Value Range and Step

PCS1900

Unit

None

Default Value

DCS1800

Default Value
Configuration Reason

DCS1800 is a commonly-used frequency band.

Configuration Rule and

You can set this parameter according to the actual frequency band

Adjustment Suggestion

planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.1.2 Load indication allowed (LoadInd)


Full Name

Load indication allowed

Abbreviation

LoadInd

3GPP Name

None

3GPP Reference

None

2-2
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Load indication is a process in which adjacent BSCs can know the load
of the cells at the border so that more reference information can be
provided in normal handovers and intra-BSC handovers.
This parameter decides whether to enable load indication and whether
LoadValidTime and LoadIndPrd are valid. If the parameter is set to No
(load indication is disabled), LoadValidTime and LoadIndPrd are invalid.
Description

Otherwise, they are valid.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

This switch can be enabled upon request. Otherwise, it should be

Adjustment Suggestion

disabled.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.1.3 Send confusion message allowed (ConfusionMsg)


Full Name

Send confusion message allowed

Abbreviation

ConfusionMsg

3GPP Name

None

2-3
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

None
A confusion message refers to a message that is sent by the SCCP to the
peer end when the SCCP receives a message at the local end but cannot

Description

process it correctly and no suitable failure message can be fed back.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

Confusion messages are sent only in the connection stage. After the

Configuration Reason

BSC and the MSC are connected, such messages do not apply.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.1.4 Inter-cell handover allowed (InHoEnable)


Full Name

Inter-cell handover allowed

Abbreviation

InHoEnable

3GPP Name

None

3GPP Reference

None

2-4
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Two methods can be used to implement a handover between two cells in


the same BSC. In one method, the BSC controls the inter-cell handover,
and the MSC is not involved in the handover flow. In the other method,
the MSC is used to implement the inter-cell handover in the BSC, and the
handover flow is similar to an inter-BSC handover flow. This parameter
indicates which method is used for inter-cell handover in the BSC. Set
this parameter to 1 unless specially required. "The parameter value 1
indicates that the inter-cell handover flow is controlled by the BSC; while
the parameter value 0 indicates that inter-cell handover flow is controlled
Description

by the MSC.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The default parameter value is set to 1 because an inter-cell handover


controlled by the BSC costs fewer overheads and thus improves the
system efficiency when the inter-cell handover is within the same BSC.
Generally, you do not have to modify this paraemter. Note: The
inter-cell handover in the BSC can only be enabled or disabled when
HoInterEnable and InHoEnable are set to 1 or 0 at the same time.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[BSC]HoInterEnable

Relationship

The inter-cell handover in the BSC can only be enabled or disabled


when HoInterEnable and InHoEnable are set to 1 or 0 at the same time.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-5
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.1.5 Send assignment failure allowed in outer direct retry


procedure (ExDRSendAssFail)
Full Name

Send assignment failure allowed in outer direct retry procedure

Abbreviation

ExDRSendAssFail

3GPP Name

None

3GPP Reference

None
This parameter decides whether to send the assignment failure message
during external directed retries. If you select Yes, the assignment failure
message will be sent to the MSC when an external directed retry fails. If

Description

you select No, no assignment failure message will be sent.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No
Enabling this switch will increase the count of assignment failures

Default Value
Configuration Reason

because the MS will still attempt directed retries after the assignment
failure message is sent. Besides, some MSCs do not support the
sending of the assignment failure message during external directed
retries. The default value "No" can avoid affecting normal counting.
Enabling this switch will increase the count of assignment failures

Configuration Rule and


Adjustment Suggestion

because the MS will still attempt directed retries after the assignment
failure message is sent. Besides, some MSCs do not support the
sending of the assignment failure message during external directed
retries. The default value "No" can avoid affecting normal counting.

Change Mode

Offline

Related features

ZGB-03-01-002 Directed Retry

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

YES

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

2-6
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.1.6 Load indication Valid Time (LoadValidTime)


Full Name

Load indication Valid Time

Abbreviation

LoadValidTime

3GPP Name

Time indication IE
48.008 Mobile Switching Centre -Base Station System (MSC-BSC) inter-

3GPP Reference

face
In a load indication procedure, the BSC periodically sends a BSSAP
LOAD INDICATION message to the MSC, informing the MSC about the
load status. The BSSAP LOAD INDICATION message contains time
indication information, indicating the valid period of the service load. The
MSC forwards the load information to adjacent BSCs via BSSAP LOAD
INDICATION message.

This parameter indicates the valid period of

the load information. 255The parameter value 255 means that the load
Description

information is valid permanently.

Managed Object

BSC
0..255

Value Range and Step

Step: 1

Unit

10 s

Default Value

18

Default Value
Configuration Reason

Generally, the validity of load information is acceptable in 180s with the


consideration that the network load rarely fluctuates greatly in such a
period.
Generally, you do not have to modify this parameter and the default

Configuration Rule and


Adjustment Suggestion

value is recommended. If the parameter value is too large, the MSC


regards that the current load has a long valid period, which cannot reflect
the actual load variation of the BSC. If the parameter value is too small,
the reported load information becomes invalid in a short time.

Change Mode

Offline

Related features

ZGB-03-04-001 BSC Load Control

Related Parameters

None

Relationship

None

2-7
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.1.7 Load Indication Period (LoadIndPrd)


Full Name

Load Indication Period

Abbreviation

LoadIndPrd

3GPP Name

None

3GPP Reference

None
In a load indication procedure, the BSC periodically sends a BSSAP
LOAD INDICATION message to the MSC, informing the MSC about the
load status. The BSSAP LOAD INDICATION message contains time
indication information, indicating the valid period of the service load. The
MSC forwards the load information to adjacent BSCs via BSSAP LOAD
INDICATION message. This parameter specifies the period for the BSC

Description

to send a BSSAP LOAD INDICATION message to the MSC.

Managed Object

BSC
10..65530

Value Range and Step

Step: 1

Unit

100 ms

Default Value

1500

Default Value

Generally, the load information of a BSC needs an update every 150s. A

Configuration Reason

longer update period may reduce the accuracy of load information.


Generally, you do not have to modify this parameter and the default

Configuration Rule and


Adjustment Suggestion

value is recommended. If the parameter value is too large, the load


indication message cannot accurately reflect the load variation of the
BSC. If the parameter value is too small, the frequent reporting of the
load indication message will cause the waste of signalling link resources.

Change Mode

Offline

2-8
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related features

ZGB-03-04-001 BSC Load Control

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.1.8 Congestion Threshold for Send Load Indication (LoadIndThs)


Full Name

Congestion Threshold for Send Load Indication

Abbreviation

LoadIndThs

3GPP Name

None

3GPP Reference

None
If the cell load in this BSC is higher than the value of this parameter, the
system initiates a load indication process, which make adjacent BSCs
know the load of the cells at the border so that more reference information

Description

can be provided in normal handovers and intra-BSC handovers.

Managed Object

BSC

Value Range and Step

0..100

Unit

Default Value

100

Default Value

It is a functional parameter and is configured to 100 (no load indication is

Configuration Reason

initiated) by default.

Configuration Rule and


Adjustment Suggestion

Currently, this parameter is not used and need not be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

2-9
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

2.1.9 Forbid Handover According to Resource Threshold of Load


Indication (LoadForbidHo)
Full Name

Forbid Handover According to Resource Threshold of Load Indication

Abbreviation

LoadForbidHo

3GPP Name

None

3GPP Reference

None
This parameter determines whether to prohibit handover to an external

Description

adjacent cell with the resource usage higher than that of load indication.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

It is a functional parameter and is configured to "No" by default.

Configuration Rule and


Adjustment Suggestion

Currently, this parameter is not used and need not be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

2-10
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

2.1.10 Resource Threshold of Load Indication for Forbid Handover


(LoadThsForbidHo)
Full Name

Resource Threshold of Load Indication for Forbid Handover

Abbreviation

LoadThsForbidHo

3GPP Name

None

3GPP Reference

None
If the resource usage of an external adjacent cell is higher than the value

Description

of this parameter, the system does not trigger handover to the cell.

Managed Object

BSC

Value Range and Step

0..100

Unit

Default Value

100

Default Value
Configuration Reason

It is a functional parameter and is configured to 100 by default, which


indicates that handover to the external adjacent cell initiating the load
indication process is not prohibited.

Configuration Rule and


Adjustment Suggestion

Currently, this parameter is not used and need not be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

2-11
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN
OMC Access Path

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

2.1.11 Support Precise Paging (PrecisePagSupport)


Full Name

Support Precise Paging

Abbreviation

PrecisePagSupport

3GPP Name

None

3GPP Reference

None
This parameter determines the switch of BSC exact paging. This function
indicates that the system performs paging in the cells for exact paging. If
the system does not page any subscriber, it performs paging within the
paging range of the core network. The exact paging cells include the Visit
Paging Cell (VPC) and Home Paging Cell (HPC). The VPC indicates a
cell around the cell where the last service exists. It can be a handover
or reselection adjacent cell, or can be configured additionally. The HPC
indicates a group of cells calculated based on the cells where latest ser-

Description

vices are triggered.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This parameter is a functional switch, which disabled by default.


Generally, configure this parameter according to operator requirements.
In the case of large paging volume, enable the exact paging function
to save CCCH channels.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]CsPrecisePaging
[Cell]PsPrecisePaging

2-12
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Only when the BSC and cell exact paging switches are both enabled,
Relationship

the system can perform exact paging. This function is applicable to


the client.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.1.12 Use HPC for Precise Paging (PrecisepagUseHpc)


Full Name

Use HPC for Precise Paging

Abbreviation

PrecisepagUseHpc

3GPP Name

None

3GPP Reference

None
If this parameter is configured to "No", only the VPC is used for exact
paging. If this parameter is configured to "Yes", both the VPC and HPC

Description

are used for exact paging.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

By default, the selection function is disabled.

Configuration Rule and

For the fixed cells such as housing and residential areas, the HPC can

Adjustment Suggestion

be used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

2-13
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.1.13 Adopt Precise Paging for repaging of Circuit Switched


Service (CsRepagPrecise)
Full Name

Adopt Precise Paging for repaging of Circuit Switched Service

Abbreviation

CsRepagPrecise

3GPP Name

None

3GPP Reference

None
When the first paging is not responded for the CS service, the core network may initiate paging for another time. This parameter determines
whether the exact paging policy is applied for subsequent paging opera-

Description

tions of the CS service in the core network.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The paging time must not be excessively long.


It is required to configure this parameter according to operator
requirements. When subscribers can accept a relatively long connection
time, enable this switch.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

2-14
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.1.14 Adopt Precise Paging for repaging of Packet Switched


Service (PsRepagPrecise)
Full Name

Adopt Precise Paging for repaging of Packet Switched Service

Abbreviation

PsRepagPrecise

3GPP Name

None

3GPP Reference

None
When the first paging is not responded for the PS service, the core network may initiate paging for another time. This parameter determines
whether the exact paging policy is applied for subsequent paging opera-

Description

tions of the PS service in the core network.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

The paging time must not be excessively long.

Configuration Rule and

requirements. When PS paging is mainly for non real-time services or

Adjustment Suggestion

subscribers can accept a relatively long connection time, enable this

It is required to configure this parameter according to operator

switch.
Change Mode

Offline

Related features

None

Related Parameters

None

2-15
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.1.15 Allow Exceed area Precise Paging for Circuit Switched


Service (CsOutAreaPag)
Full Name

Allow Exceed area Precise Paging for Circuit Switched Service

Abbreviation

CsOutAreaPag

3GPP Name

None

3GPP Reference

None
This parameter determines whether the exact paging of CS service covers
the cells out of the paging range of core network. The paging of CS service
is usually applied for location cells. However, some VPCs and HPCs may

Description

not in these location cells.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Usually, subscribers are not out of the paging range of core network.
Usually, this function is disabled. When the location cell is updated and
the BSC fails to acquire IMSI to record the subscriber location, this
function can be enabled.

Change Mode

Offline

Related features

None

Related Parameters

None

2-16
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.1.16 Allow Exceed area Precise Paging for Packet Switched


Service (PsOutAreaPag)
Full Name

Allow Exceed area Precise Paging for Packet Switched Service

Abbreviation

PsOutAreaPag

3GPP Name

None

3GPP Reference

None
This parameter determines whether the exact paging of PS service covers
the cells out of the paging range of core network. The paging of PS service
is usually applied for routing cells. However, some VPCs and HPCs may

Description

not in these routing cells.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Usually, subscribers are not out of the paging range of core network.
Usually, this function is disabled. When the routing cell is updated and
the BSC fails to acquire IMSI to record the subscriber location, this
function can be enabled.

Change Mode

Offline

Related features

None

Related Parameters

None

2-17
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.1.17 Paging Repeat Time for Circuit Switched Service


(CsPagingRepeatTime)
Full Name

Paging Repeat Time for Circuit Switched Service

Abbreviation

CsPagingRepeatTime

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum retry times of CS service paging
(exact paging excluded). When the first paging is not responded, the
system can initiate multiple paging operations according to the value of

Description

this parameter.

Managed Object

BSC

Value Range and Step

0..2

Unit

times

Default Value

Default Value

Usually, multiple paging operations are applied on the BSC only when

Configuration Reason

this function is not applied in the core network.

Configuration Rule and

Multiple paging operations are applied on the BSC only when this

Adjustment Suggestion

function is not applied in the core network.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None
2-18

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Impact on Equipment

Impact on service

Negotiation With CN

YES

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.1.18 Paging Repeat Time for Packet Switched Service


(PsPagingRepeatTime)
Full Name

Paging Repeat Time for Packet Switched Service

Abbreviation

PsPagingRepeatTime

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum retry times of PS service paging
(exact paging excluded). When the first paging is not responded, the
system can initiate multiple paging operations according to the value of

Description

this parameter.

Managed Object

BSC

Value Range and Step

0..2

Unit

times

Default Value

Default Value

Usually, multiple paging operations are applied on the BSC only when

Configuration Reason

this function is not applied in the core network.

Configuration Rule and

Multiple paging operations are applied on the BSC only when this

Adjustment Suggestion

function is not applied in the core network.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

0
2-19

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN
OMC Access Path

YES
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.1.19 Automatic Resource Indication Threshold (ResourceIndThs)


Full Name

Automatic Resource Indication Threshold

Abbreviation

ResourceIndThs

3GPP Name

None

3GPP Reference

None
This parameter indicates the rate of available channels, which is used
as a threshold for determining whether the BSC automatically sends a
resource indication message to the MSC. When the rate of available
channels in a cell is lower than this threshold, the BSC is required to
inform the MSC about the resource status in the cell by sending a
resource indication message. O&M is used to configure this parameter.
The four modes of resource indication from BSC are as follows:
Automatic mode: Upon receiving a BSSAP RESOURCE REQUEST
message, the BSC immediately responds with a BSSAP RESOURCE
INDICATION message containing no resource information. After that,
the BSC automatically sends a BSSAP RESOURCE INDICATION
message to the MSC when the condition of automatic response is met,
which may be a threshold or message interval preset by the O&M of the
BSC. Periodicity IE in the BSSAP RESOURCE REQUEST message
is used to indicate the interval between messages when the value of
Periodicity IE is not 0. Periodicity IE with a value of 0 will be neglected
by the BSC. BSSAP RESUORCE INDICATION
One-time mode: Upon receiving a BSSAP RESOURCE REQUEST
message, the BSC immediately responds with a BSSAP RESOURCE
INDICATION message containing the resource information. If the
BSSAP RESOURCE REQUEST message does not contain Extended
Resource Indication IE, the BSC stops sending the resource information
and waits for the next BSSAP RESOURCE REQUEST message. If the
BSSAP RESOURCE REQUEST message contains Extended Resource
Indication IE, the BSC complies with the mode specified by Subsequent

Description

Mode in the message, that is, mode 4. If the previous mode is 1 or 3,

2-20
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

the BSC will use mode 1 or 3. If the previous mode is not 1 or 3, the
BSC will use mode 4. .
Periodic mode: Upon receiving a BSSAP RESOURCE REQUEST
message, the BSC immediately responds with a BSSAP RESOURCE
INDICATION message containing the resource information, and then
periodically sends a BSSAP RESOURCE INDICATION message. If the
value of Periodicity IE in the BSSAP RESOURCE REQUEST message
is not 0, the period of sending the indication message is the product of
100ms and Periodicity IE. If the value of Periodicity IE is 0, the BSSAP
RESOURCE REQUEST message is regarded as an error message.
Stop mode: Upon receiving a BSSAP RESOURCE REQUEST message,
the BSC immediately responds with a BSSAP RESOURCE INDICATION
message containing no resource information. And then the BSC will not
send the resource information of the cell to the MSC any longer.
Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

Default Value

30
The default value is an experimental value based on the need when

Default Value

the BSC should report a resource indication to the MSC. The report of

Configuration Reason

resource indication is recommended when the rate of available channels


is lower than 30%.
Generally, the default value is recommended. The larger the parameter

Configuration Rule and


Adjustment Suggestion

value is, the more easily the automatic resource indication is triggered.
The smaller the parameter value is, the more difficultly the automatic
resource indication is triggered.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

2-21
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.1.20 BSC maximum reset number (BscMaxResetNum)


Full Name

BSC maximum reset number

Abbreviation

BscMaxResetNum

3GPP Name

None

3GPP Reference

None
This parameter indicates the maximum number of BSC resets. After the
BSC sends the BSSAP RESET message to the MSC, if the BSC does
not receive the BSSAP RESET ACKNOWLEDGE message from the
MSC in the specified time T4, the reset process will be repeated.
The BSSAP RESET message will be sent repeatedly at most N times. If
the BSC does not receive a response after N times, it will stop the reset

Description

process and notify the OMS. N depends on this parameter.

Managed Object

BSC

Value Range and Step

1..255; step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Generally, It is enough to repeat the BSC reset process three times.


Generally, the default value is recommended. The higher the value is,
the more the BSC will repeat the reset if it does not receive the BSSAP
RESET ACKNOWLEDGE message from the MSC.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-22
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.1.21 MR report support (MrRptEnable)


Full Name

MR report support

Abbreviation

MrRptEnable

3GPP Name

None

3GPP Reference

None
This parameter decides whether to enable the data report function and
use it along with MrRptTimap. If this function is enabled, measurement
data will be reported to the NMS. The function is used to store the measurement reports from NEs into the NMS for the purpose of analyzing MS

Description

users' behaviors.

Managed Object

BSC
Yes, No
Yes: Enable

Value Range and Step

No: Disable

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

When you enable the MR data collection function, you should enable

Adjustment Suggestion

this parameter.

Change Mode

Offline

Related features

ZGO-06-01-005 Massive Measurement Report

Related Parameters

None

Relationship

None

Related Interfaces

ABIS

Impact on Equipment

Impact on service

Negotiation With CN

NO
2-23

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.1.22 HBTS scan site number (HBTSScanSiteNum)


Full Name

HBTS scan site number

Abbreviation

HBTSScanSiteNum

3GPP Name

None

3GPP Reference

None

Description

value 0 means disabling the fixed-time scan function.

Managed Object

BSC

This parameter indicates the number of S8001 sites in each scan. 0The

0..10
Value Range and Step

Step: 1

Unit

None

Default Value

10

Default Value

Each CMP supports 256 sites at most. It is reasonable that the CMP

Configuration Reason

should scan 10 sites each time due to its capacity limits.

Configuration Rule and

The higher the value is, the more heavily the CMP is loaded. The default

Adjustment Suggestion

value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]HBTSScanBT
[BSC]HBTSScanCyc

Relationship

If this parameter is set to 0, the parameters HBTSScanCyc and


HBTSScanBT are configurable but invalid.

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Radio Basic Proerty

2-24
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.1.23 Range of Barang


Full Name

Range of Barang

Abbreviation

None

3GPP Name

None

3GPP Reference

None
The value of this parameter can be a single frequency or a frequency
range, which is sent to the MS in the CHANNEL RELEASE message.
When selecting a cell, the MS can detect some frequencies first.
You can add a frequency range by setting the minimum value and the
maximum value in the BARANGE pane and clicking Add. A same value
range can be shared by different global resources.

Description

Frequency ranges must not have intersections.

Managed Object

BSC
PGSM (1..124)
EGSM (0..124, 975..1023)
DCS1800 (512..885)
GSM1900 (512..810)

Value Range and Step

GSM850 (128..251)

Unit

None

Default Value

0&&0

Default Value

Normal services can be ensured even if you set no frequency for the

Configuration Reason

prioritized detection made by the MS.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

ABIS

Impact on Equipment

Impact on service

0
2-25

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Radio Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.2 Functional Switch


2.2.1 RIM support (RIMSupport)
Full Name

RIM support

Abbreviation

RIMSupport

3GPP Name

RIM

3GPP Reference

3GPP TS 48.018
This parameter is a switch to support RIM function.
The RIM function is used for fast cell reselection between two BSCs
(including BSC-RNC cell reselection). During an external Network
Assisted Cell Change (NACC), the BSC sends the system information
of the target cell to the MS in the source cell before the MS starts the
cell reselection. In this way, the MS can quickly get access to the target
cell because the time needed for receiving the system information of the
target cell is saved after the MS reselects the target cell.
The external NACC of the BSC needs to acquire the system information
of the cell outside the BSC through a RAN Information Management
(RIM) process between the SGSN and the BSC.
If the BSC supports the RIM function, an RIM process is triggered by
service to acquire, store, and update the system information of the
external cell. Accordingly, the BSC, which supports the RIM function,
shall provide the system information of a cell inside the BSC when
required by another BSC/RNC, and informs this BSC/RNC about the

Description

change when the system information of the internal cell changes.

Managed Object

BSC
Yes/No

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

2-26
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


Enable this switch when the external NACC function is enabled. After

Configuration Rule and


Adjustment Suggestion

the switch is enabled, an RIM process can be initiated between the


SGSN and the BSC to get the system information of a cell outside the
BSC. In this way, the MS can get access to the target cell more quickly
during a cell reselection.

Change Mode

Offline

Related features

ZGO-02-02-011 Inter-BSC NACC

Related Parameters

[BSC]RIMRetryTimes

Relationship

The parameter RIMRetryTimes is valid only when this switch is enabled.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.2.2 RIM retry times (RIMRetryTimes)


Full Name

RIM retry times

Abbreviation

RIMRetryTimes

3GPP Name

None

3GPP Reference

None
This parameter indicates the number of RIM retries. The maximum num-

Description

ber of RIM retries is 3.

Managed Object

BSC
0..3

Value Range and Step

Step: 1

Unit

None

Default Value

2-27
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is 0 because the RIM function is disabled by default.


Set this parameter for external NACC when the RIM function is enabled.
It is recommended to disable the RIM function because it requires the
support of the CN.

Change Mode

Offline

Related features

ZGO-02-02-011 Inter-BSC NACC

Related Parameters

[BSC]RIMSupport

Relationship

This parameter can be set only when the RIM function is enabled.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.2.3 Different reselection parameter in idle and transfer status


support (PSReselParam2)
Full Name

Different reselection parameter in idle and transfer status support

Abbreviation

PSReselParam2

3GPP Name

None

3GPP Reference

None
This parameter indicates whether two sets of measurement and reselection parameters can be used at the same time in idle state and packet

Description

transmission state. This function is not in use currently.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

2-28
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Default Value
Configuration Reason

This function is disabled by default because this parameter is not in use.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline
ZGO-02-02-013 Different Cell Reselection Parameters for IDLE and AC-

Related features

TIVE Status

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.2.4 Handover synchronization indication support (Info_0_16)


Full Name

Handover synchronization indication support

Abbreviation

Info_0_16

3GPP Name

None

3GPP Reference

None
This parameter decides whether the handover synchronization
information contains the synchronization indication bit and whether the
handover completion message contains the Mobile Time Difference unit

Description

and normal cell indication.


It indicates whether handover synchronization indication is supported.
If the parameter's value is Yes, handover synchronization indication is
supported. For both synchronization handover and asynchronization
handover, ROT in the handover completion message is 1.

Managed Object

None

Value Range and Step

Yes/No

2-29
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

No

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.2.5 Switch of TRAU frame synchronized monitor (Info_4_5)


Full Name

Switch of TRAU frame synchronized monitor

Abbreviation

Info_4_5

3GPP Name

call release after loss of TRAU frame synchronization

3GPP Reference

3GPP TS 48.060, 3GPP TS 48.061


This parameter indicates whether you can release the call when TRAU

Description

frame synchronization has been lost for a period.

Managed Object

BSC

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value
Configuration Reason

None

2-30
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

[BSC]TuTrauSyn

Relationship

The timer of TRAU frame synchronization takes effect only if Info_4_5


is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.2.6 PS handover support (PSHoSupp)


Full Name

PS handover support

Abbreviation

PSHoSupp

3GPP Name

None

3GPP Reference

None

Description

This parameter determine whether PS handover is supported.

Managed Object

BSC

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

2-31
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.2.7 Enable PS Handover Indications in Inter-BSS handover


(EnablePSHoIndi)
Full Name

Enable PS Handover Indications in Inter-BSS handover

Abbreviation

EnablePSHoIndi

3GPP Name

None

3GPP Reference

None
It determines whether PS Handover Indications is enabled during

Description

inter-BSS handover.

Managed Object

BSC

Value Range and Step

Yes, No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

2-32
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.2.8 Request SI/PSI (EnableRequestPSI)


Full Name

Request SI/PSI

Abbreviation

EnableRequestPSI

3GPP Name

None

3GPP Reference

None

Description

It determine if request SI/PSI is enabled.

Managed Object

BSC

Value Range and Step

Yes, No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-33
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.2.9 Support EMLPP (SupportEMLPP)


Full Name

Support EMLPP

Abbreviation

SupportEMLPP

3GPP Name

None

3GPP Reference

None

Description
Managed Object
Value Range and Step

This parameter determine whether EMLPP is supported in this cell.


This parameter is supported from version 6.20.61.
BSC
Yes/No
0: No; 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

None
2-34

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Detail

None

2.2.10 DFCA support (DFCASupport)


Full Name

DFCA support

Abbreviation

DFCASupport

3GPP Name

None

3GPP Reference

None
This parameter determines whether to support the Dynamic Frequency

Description

and Channel Allocation (DFCA) function.


Unsupported

Managed Object

BSC

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-35
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.2.11 Support resource optimizing by service (SuppResOpBySe


rvice)
Full Name

Support resource optimizing by service

Abbreviation

SuppResOpByService

3GPP Name

None

3GPP Reference

None
This parameter determines whether to enable the function of resource

Description

control based on the classification of subscriber services.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Enable this switch as required.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.2.12 Identify of special service (SpecServiceIdentify)


Full Name

Identify of special service

2-36
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Abbreviation

SpecServiceIdentify

3GPP Name

None

3GPP Reference

None
This parameter determines which solution (DSCP or BSSGP) is used to

Description

identify the specific service.

Managed Object

BSC
0: DSCP

Value Range and Step

1: BSSGP extend

Unit

None

Default Value

Default Value
Configuration Reason

By default, the DSCP solution is used.

Configuration Rule and

This parameter requires negotiation with the core network and then

Adjustment Suggestion

determines the solution used for identification.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

YES

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.2.13 DTM Enhance Capability (DTMEnhanceCapa)


Full Name

DTM Enhance Capability

Abbreviation

DTMEnhanceCapa

3GPP Name

None

3GPP Reference

None

2-37
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines whether the BSC supports enhanced DTM


functions. If yes, the MS establishes the DTM service without releasing
Description

the current PS service.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

These functions are not provided in the current version.

Configuration Rule and

It is required to configure this parameter according to the DTM settings

Adjustment Suggestion

and the functions supported by the current version.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]DTMEnhanceCap

Relationship

This parameter is valid after the switch of enhanced DTM functions for
the cell is enabled.

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.2.14 E-UTRAN CCN support (EUtranCCN)


Full Name

E-UTRAN CCN support

Abbreviation

EUtranCCN

3GPP Name

E-UTRAN_CCN_ACTIVE

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines whether to enable the CCN function between

Description

a GSM cell and an adjacent LTE cell.

2-38
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and

This function is not implemented in the current version. Hence, it is

Adjustment Suggestion

recommended that this function be disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.2.15 Duration of judging from concurrent to special service


(ConcurrentJudge0)
Full Name

Duration of judging from concurrent to special service

Abbreviation

ConcurrentJudge0

3GPP Name

None

3GPP Reference

None
TBF bears both normal service and specific service. If the time for receiving a data packet of specific service exceeds the configured time, the

Description

system considers that the TBF bears only the specific service.

Managed Object

BSC

Value Range and Step

0..60000

2-39
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

ms

Default Value

10000

Default Value

The precision and timeliness of identification for the specific service are

Configuration Reason

taken into consideration.


This parameter cannot be configured too low, which may cause the

Configuration Rule and


Adjustment Suggestion

ping-pong oscillation of service identification between the concurrent


service and specific service. This parameter cannot be configured too
high, which may affect the identification timeliness from the concurrent
service to the specific service.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.2.16 Number of llc judging from concurrent to special service


(ConcurrentJudge1)
Full Name

Number of llc judging from concurrent to special service

Abbreviation

ConcurrentJudge1

3GPP Name

None

3GPP Reference

None
If the number of LLC frames for the normal service is larger than the value
of this parameter during judgment from the concurrent service to the spe-

Description

cific service, the system restarts this judgment process.

Managed Object

BSC

Value Range and Step

0..1000

2-40
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Unit

None

Default Value

20

Default Value

The short-time complex service that may occur during conversion from

Configuration Reason

the concurrent service to the specific service is taken into consideration.


The larger the value of this parameter, the higher the possibility of

Configuration Rule and


Adjustment Suggestion

being considered as the specific service but the lower the precision.
The smaller the value of this parameter, the higher the requirement on
conversion from the concurrent service to the specific service and the
higher the precision.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.2.17 Duration of judging from special to non-special service


(ConcurrentJudge2)
Full Name

Duration of judging from special to non-special service

Abbreviation

ConcurrentJudge2

3GPP Name

None

3GPP Reference

None
TBF bears both normal service and specific service. If the time for receiving a data packet of non-specific service exceeds the configured time,
the system considers that the TBF bears the concurrent service or nor-

Description

mal service.

Managed Object

BSC

2-41
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Value Range and Step

0..60000

Unit

ms

Default Value

5000

Default Value

The precision and timeliness of identification from the specific service to

Configuration Reason

the concurrent service or normal service are taken into consideration.


This parameter cannot be configured too low, which may cause the

Configuration Rule and


Adjustment Suggestion

ping-pong oscillation of service identification between the specific


service and non-specific service. This parameter cannot be configured
too high, which may affect the identification timeliness from the specific
service to the concurrent service or normal service.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.2.18 Number of llc judging from special to non-special service


(ConcurrentJudge3)
Full Name

Number of llc judging from special to non-special service

Abbreviation

ConcurrentJudge3

3GPP Name

None

3GPP Reference

None
If the number of LLC frames for the specific service is larger than the
value of this parameter during judgment from the specific service to the
concurrent service or normal service, the system restarts this judgment

Description

process.

2-42
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Managed Object

BSC

Value Range and Step

0..1000

Unit

None

Default Value

20

Default Value
Configuration Reason

The short-time specific service that may occur during conversion from
the specific service to the concurrent service or normal service is taken
into consideration.
The larger the value of this parameter, the higher the possibility of
being converted from the specific service to the concurrent service or

Configuration Rule and

normal service but the lower the precision. The smaller the value of this

Adjustment Suggestion

parameter, the higher the requirement on conversion from the specific


service to the concurrent service or normal service and the higher the
precision.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.2.19 If get Utran classmrak information from UE (GetUtranClass)


Full Name

If get Utran classmrak information from UE

Abbreviation

GetUtranClass

3GPP Name

Null

3GPP Reference

Null

2-43
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If the UE performs handover from 3G network to 2G network, the


Handover Request message may not contain the UtranClassmark of the
MS, or the message contain the wrong information of UtranClassmark. If
the UE later performs a 2G-to-3G handover, the operation is easy to fail
due to lack of the correct UtranClassmark information.
If the switch is on, after the UE perform handover from the external
network to the BSC, the BSC will initiate a classmark request, requiring
Description

the UE to report its UtranClassmark.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value

The classmark request procedure increases the system load, so the

Configuration Reason

switch is off generally.

Configuration Rule and


Adjustment Suggestion

If the connected RNC sends a handover request with incomplete or


outdated information, which reduces the success rate for 2G-to-3G
handover, enabling the feature is necessary.

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Functional Switch

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

2-44
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.3 Other Parameters


2.3.1 Supervision Timer of LCS (LcsSuperVision)
Full Name

Supervision Timer of LCS

Abbreviation

LcsSuperVision

3GPP Name

None

3GPP Reference

None
This parameter is a timer used for supervising a location process.
Start: When the BSC sends a location request to the SMLC.
Stop: When a location acknowledgement message is received.

Description

At expiry: Terminate the location process.

Managed Object

BSC
100..1000

Value Range and Step

Step: 1

Unit

100 ms

Default Value

250

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Generally, a location process can be completed in 25 seconds.


Generally, the default value is recommended. The larger the parameter
value is, the longer the waiting time is after a location request is sent.
Similarly, a smaller parameter value indicates a shorter waiting time.

Change Mode

Offline

Related features

ZGO-01-03-002 LCS with CGI+TA &ZGO-01-03-003 LCS with AGPS

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-45
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.3.2 Radio Timer of LCS (LcsRadio)


Full Name

Radio Timer of LCS

Abbreviation

LcsRadio

3GPP Name

None

3GPP Reference

None
This parameter is a timer used for supervising the sending of radio
information in the location process.
Start: When a location-related message is sent to the MS.
Stop: When an acknowledgement message is received from the MS.

Description

At expiry: Terminate the location process.

Managed Object

BSC
10..100

Value Range and Step

Step: 1

Unit

100 ms

Default Value

50

Default Value

Generally, the sending of radio information in the location process can

Configuration Reason

be completed in five seconds.

Configuration Rule and

value is, the longer the waiting time is after the MS sends a location

Adjustment Suggestion

message. Similarly, a smaller parameter value indicates a shorter

Generally, the default value is recommended. The larger the parameter

waiting time.
Change Mode

Offline

Related features

ZGO-01-03-002 LCS with CGI+TA &ZGO-01-03-003 LCS with AGPS

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-46
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.3.3 LCS wait intra BSS handover timer (LcsWaitInTraHO)


Full Name

LCS wait intra BSS handover timer

Abbreviation

LcsWaitInTraHO

3GPP Name

None

3GPP Reference

None
This parameter specifies the waiting time for the completion of an
intra-BSC handover.
Start: An intra-BSC handover is initiated during service location.
Stop: A handover complete message is received.

Description

At expiry: Terminate the location process.

Managed Object

BSC
20..100

Value Range and Step

Step: 1

Unit

100 ms

Default Value

60

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Generally, six seconds are enough for an intra-BSC handover.


Generally, the default value is recommended. The larger the parameter
value, the longer the waiting time is after a handover request is sent.
Similarly, a smaller parameter value means a shorter waiting time.

Change Mode

Offline

Related features

ZGO-01-03-002 LCS with CGI+TA &ZGO-01-03-003 LCS with AGPS

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-47
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.3.4 Monitor physical context request (RmsT9108)


Full Name

Monitor physical context request

Abbreviation

RmsT9108

3GPP Name

None

3GPP Reference

None

Description

reserved to monitor physical context requests in future.

Managed Object

BSC

Value Range and Step

20

Unit

100 ms

Default Value

20

This parameter indicates the timer T9108 that is not used currently and is

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.5 Timer for waiting message from A-interface (TWaitMsg)


Full Name

Timer for waiting message from A-interface

Abbreviation

TWaitMsg

2-48
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

3GPP Name

None

3GPP Reference

None
This parameter indicates the protection time to wait for messages in
WORK status in the RanAWorker process. The RanAWorker process
is the working process of the RANA module.
Start: A RANA instance is created.
Stop: A message is received from the MSC.
At expiry: The instance will be released.

Description

Related timer: None

Managed Object

BSC
5..20

Value Range and Step

Step: 1

Unit

100 ms

Default Value

20

Default Value

Two seconds are long enough for the A interface to transmit signalling

Configuration Reason

and for the MSC to process signalling.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.6 Timer for RANCSEST waiting (TWaitRancsEst)


Full Name

Timer for RANCSEST waiting

2-49
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

TWaitRancsEst

3GPP Name

None

3GPP Reference

None
This parameter indicates the protection time to wait for a resource
request in the RANCS process. The RANCS process is a process to
handle CS services.
Start: The RANA module receives an external handover request and
asks the RANCS module for a channel.
Stop: A response is received from the RANCS module.
At expiry: The handover failure message will be sent to the A interface.

Description

Related timer: None

Managed Object

BSC
10..100

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value

Generally, ten seconds are long enough for channel request, activation,

Configuration Reason

and connection in the BSC.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-50
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.3.7 Timer for RANCSCLECOM waiting (TWaitRancsCleCom)


Full Name

Timer for RANCSCLECOM waiting

Abbreviation

TWaitRancsCleCom

3GPP Name

None

3GPP Reference

None
This parameter indicates the time to wait for the RANCS process to
respond to ClearCom in the RanAWorker process. The RanAWorker
process is the working process of the RANA module.
Start: The clear command is sent to the RANCS module.
Stop: A response is received from the RANCS module.
At expiry: The release will continue.

Description

Related timer: None

Managed Object

BSC
10..30

Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value

Generally, three seconds are long enough for channel release,

Configuration Reason

activation, disconnection, and connection in the BSC.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-51
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.3.8 Timer for CCM waiting (CcmWaitTimer)


Full Name

Timer for CCM waiting

Abbreviation

CcmWaitTimer

3GPP Name

None

3GPP Reference

None
This parameter indicates a timer that is used when the BTS waits
for disconnection, connection, and deactivation in dynamic channel
switching.
Start: The CCM starts channel switching.
Stop: A response is received from the connecting module and the BTS.
At expiry: The message will be sent to the BTS again.

Description

Related timer: None

Managed Object

BSC
45..55

Value Range and Step

Step: 1

Unit

100 ms

Default Value

45

Default Value

The default value 4.5 seconds are long enough for the Abis interface to

Configuration Reason

transmit signalling and for the BTS to carry out the disconnection.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGB-03-02-006 Dynamic Channel Management

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-52
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.3.9 Get static parameter timer (GetStaticParamTimer)


Full Name

Get static parameter timer

Abbreviation

GetStaticParamTimer

3GPP Name

None

3GPP Reference

None
This is a statistical parameter that is used to regularly poll the UPU unit
under the CMP in the RancRrm process.
Start: The timer is set periodically after power on.
Stop: None.
At expiry: The RancRrm will query information about resource
occupation from the UPU unit.

Description

Related timer: None

Managed Object

BSC
60..600

Value Range and Step

Step: 1

Unit

100 ms

Default Value

120

Default Value

The default value 12 seconds can avoid both slow processing and

Configuration Reason

system load increase.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-53
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.3.10 Starting time for oriented retry (RmsT10)


Full Name

Starting time for oriented retry

Abbreviation

RmsT10

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to wait for the start of directed retry. The
timer is started to wait for queuing, forced handover, and forced release
actions when the cell fails to assign an available channel. When the
timer expires, a directed retry process is initiated.
Start: The cell fails to assign an available channel.
Stop: An available channel resource is obtained after queuing, forced
handover, and forced release.

Description

At expiry: Initiate a directed retry.

Managed Object

BSC
50..150

Value Range and Step

Step: 1

Unit

100 ms

Default Value

60

Default Value

Six seconds are enough for the cell to complete the queuing, forced

Configuration Reason

handover, and forced release process.

Configuration Rule and

Set the parameter value in consideration of the time needed for queuing

Adjustment Suggestion

preemption.

Change Mode

Offline

Related features

ZGB-03-01-002 Directed_Retry

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-54
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.3.11 TFO Enable (TFOControl_0)


Full Name

TFO Enable

Abbreviation

TFOControl_0

3GPP Name

None

3GPP Reference

None
This parameter, used for TFO control, indicates whether TFO is enabled.
0: Disable; 1: Enable
When this switch is disabled, the other switches for TFO control are also
disabled. That is, when the value of TFOControl_0 is 0, the values of
TFOControl_1, TFOControl_2 and TFOControl_3 are 0 too.
TFO is a in-band protocol that is used by the TCs of both parties for
encoding/decoding negotiation after the setup of a call. To improve the
speech quality, the voice frames in the air interface are directly sent
to the receiving party with the decoder of the sending party and the
encoder of the receiving party bypassed.
If two cells do not support AMR version, a TFO call can be successfully
set up between them once they support the same voice version. If two
cells support AMR version, a TFO call can be successfully set up only
when they use the same voice encoding/decoding type too. If different
voice encoding/decoding types are used, the setup of a TFO call will fail.
In the case of IPA, the CN is responsible for the negotiation of voice

Description

encoding.

Managed Object

BSC

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


Enable this switch when TFO support is required. It is recommended
to enable TFO in scenarios requiring high voice quality because TFO
can improve the voice MOS.

Change Mode

Offline

Related features

ZGO-04-02-006 TFO

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

2-55
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set
ID->BSC Function->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.12 External cell load notify (Info_0_0)


Full Name

External cell load notify

Abbreviation

Info_0_0

3GPP Name

None

3GPP Reference

None
This parameter decides whether to include the load information of a cell
into the information element "Old BSS to New BSS Information" when the
services of the cell under the current BSC are handed over to a cell under

Description

another BSC.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Generally, the default value is recommended. However, you can enable

Adjustment Suggestion

this function if necessary.

Change Mode

Offline

Related features

ZGB-03-03-003 LAPD Cluster

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-56
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.13 Neighbor cell load valid duration (Info_0_1)


Full Name

Neighbor cell load valid duration

Abbreviation

Info_0_1

3GPP Name

None

3GPP Reference

None
This parameter indicates the validity period of a neighbor cell's load infor-

Description

mation.

Managed Object

BSC
1..255

Value Range and Step

Step: 1

Unit

10 s

Default Value

Default Value
Configuration Reason

Generally, the validity of a neighbor cell's load information is acceptable


in 60s with the consideration that the load in a cell rarely fluctuates
greatly in such a period.
Generally, the default value is recommended. If the parameter value

Configuration Rule and


Adjustment Suggestion

is too large, the neighbor cell deems that the load information has a
long validity period, which cannot reflect the actual load information in
time. If the parameter value is too small, the load information will be
reported frequently.

Change Mode

Offline

Related features

ZGB-03-03-003 LAPD Cluster

Related Parameters

[BSC]Info_0_0

Relationship

This parameter is valid only when the switch Info_0_0 is enabled.

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO
2-57

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.14 LMU build request deal or not (Info_1_0)


Full Name

LMU build request deal or not

Abbreviation

Info_1_0

3GPP Name

None

3GPP Reference

None
This parameter decides whether to process the Location Measurement
Unit (LMU) establishment request.
No: Not to process

Description

Yes: To process

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Generally, the default value is recommended. However, you can enable

Adjustment Suggestion

this function if necessary.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

2-58
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.15 MBMS request deal or not (Info_1_1)


Full Name

MBMS request deal or not

Abbreviation

Info_1_1

3GPP Name

None

3GPP Reference

None
This parameter decides whether to process the Multimedia Broad-

Description

cast/Multicast Service (MBMS) request.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Generally, the default value is recommended. However, you can enable

Adjustment Suggestion

this function if necessary.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-59
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.3.16 Channel request reserved field deal or not (Info_1_2)


Full Name

Channel request reserved field deal or not

Abbreviation

Info_1_2

3GPP Name

None

3GPP Reference

None
This parameter decides whether to process the reserved field Channel
Request. When this switch is enabled, if Random Access Reference in
the Channel Request message is 0x61, 0x63, or 0x65, the system will

Description

not process the channel request.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Generally, the default value is recommended. However, you can enable

Adjustment Suggestion

this function if necessary.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.17 MS power hold in handover option (Info_0_9)


Full Name

MS power hold in handover option


2-60

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Abbreviation

Info_0_9

3GPP Name

None

3GPP Reference

None
This parameter decides whether to support MS power optimization for
non-rescue handovers. Generally, when the handover command is issued to an MS, the MS is required to use the maximum transmit power.
However, this will result in strong interferences. This switch is designed
to reduce the interferences when multiple MSs are handed over with the
maximum transmit power. When enabled, the switch serves as a threshold. When the BSC sends a handover command to the MS for a non-rescue handover, such as PBGT handover, if the current level is higher than
the threshold, it means that the target cell has better signal quality. In this
case, the current transmit power, instead of the maximum transmit power,

Description

should be used.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


Generally, the default value is recommended. However, you can enable
this function if necessary. Enabling it can reduce interferences in the
network.

Change Mode

Offline

Related features

ZGO-02-02-020 Power Optimization After Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-61
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.3.18 Signal level threshold of target cell (Info_0_10)


Full Name

Signal level threshold of target cell

Abbreviation

Info_0_10

3GPP Name

None

3GPP Reference

None
This parameter is valid when the MS power optimization for non-rescue
handovers is enabled. When the BSC sends a handover command to the
MS for a non-rescue handover, such as PBGT handover, if the current
level is higher than the threshold, it means that the target cell has better signal quality. In this case, the current transmit power, instead of the

Description

maximum transmit power, should be used.

Managed Object

BSC
0 ..63, step: 1
0: < -110 dBm
1: -110 dBm..-109 dBm
2: -109 dBm..-108 dBm
...
62: -49 dBm..-48 dBm

Value Range and Step

63: > -48 dBm

Unit

None

Default Value

27

Default Value
Configuration Reason

The level value -83 dB is enough for normal services.


Generally, the default value is recommended. The higher the value is,

Configuration Rule and

the less likely the signals in the target cell are to reach the threshold.

Adjustment Suggestion

Setting this parameter to a proper value can reduce uplink interferences


has good effect on network indicators.

Change Mode

Offline

Related features

ZGB-02-02-002 Basic Handover Decision

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others
2-62

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.19 Iur-G interface support (IurgSupport)


Full Name

Iur-G interface support

Abbreviation

IurgSupport

3GPP Name

None

3GPP Reference

None
This parameter indicates whether to support the Iur-g interface. 0: No;
1: Yes
0: Disable

Description

1: enable

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


This switch can be enabled upon request. Otherwise, it should be
disabled. Enabling Iur-g can increase the success rate of two thirds of
handovers.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Iur-g

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

2-63
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.20 Overload threshold of non real-time load (NRTThs_0)


Full Name

Overload threshold of non real-time load

Abbreviation

NRTThs_0

3GPP Name

None

3GPP Reference

None
This parameter indicates the overload threshold of non-real-time services.
When the load of non-real-time services is equal to or higher than the
threshold, it is regarded that the scell is overloaded with non-real-time
services. Non-real-time services refer to PS services. The load is calculated by dividing the number of occupied PDCHs (including dynamic

Description

PDCHs and static PDCHs) by the number of available PDCHs.

Managed Object

BSC
1..99

Value Range and Step

Step: 1

Unit

Default Value

90

Default Value

Generally, it is regarded that the cell is overloaded if more than 90%

Configuration Reason

of radio resources are occupied.

Configuration Rule and


Adjustment Suggestion

The higher the value is, the more likely the cell will be to be selected by
the RNC as the target cell for re-direction.
NRTThs_0>NRTThs_1>NRTThs_2

Change Mode

Offline

Related features

None

Related Parameters

[BSC]IurgSupport

Relationship

This parameter becomes valid when IurgSupport is set to Yes.

Related Interfaces

Iur-g

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork->BSC Managed Element->Config SetBSC


Function->Others
2-64

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.21 High threshold of non real-time load (NRTThs_1)


Full Name

High threshold of non real-time load

Abbreviation

NRTThs_1

3GPP Name

None

3GPP Reference

None
This parameter indicates the upper overload threshold of non-real-time
services. When the load of non-real-time services is equal to or higher
than the threshold but lower than NRTThs_0, it is regarded that the cell
is overloaded with non-real-time services. Non-real-time services refer to
PS services. The load is calculated by dividing the number of occupied
PDCHs (including dynamic PDCHs and static PDCHs) by the number of

Description

available PDCHs.

Managed Object

BSC
1..99

Value Range and Step

Step: 1

Unit

Default Value

60

Default Value

Generally, it is regarded that the cell is overloaded if more than 60%

Configuration Reason

of radio resources are occupied.

Configuration Rule and


Adjustment Suggestion

The higher the value is, the more likely the cell will be to be selected by
the RNC as the target cell for re-direction.
NRTThs_0>NRTThs_1>NRTThs_2

Change Mode

Offline

Related features

None

Related Parameters

[BSC]IurgSupport

Relationship

This parameter becomes valid when IurgSupport is set to Yes.

Related Interfaces

Iur-g

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-65
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork->BSC Managed Element->Config SetBSC


Function->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.22 Low threshold of non real-time load (NRTThs_2)


Full Name

Low threshold of non real-time load

Abbreviation

NRTThs_2

3GPP Name

None

3GPP Reference

None
This parameter indicates the lower overload threshold of non-real-time
services. When the load of non-real-time services is equal to or higher
than the threshold but lower than NRTThs_1, it is regarded that the cell
is moderately loaded with non-real-time services. Otherwise, the load of
non-real-time services is regarded low. Non-real-time services refer to
PS services. The load is calculated by dividing the number of occupied
PDCHs (including dynamic PDCHs and static PDCHs) by the number of

Description

available PDCHs.

Managed Object

BSC

Value Range and Step

1..99

Unit

Default Value

20

Default Value

Generally, it is regarded that the cell load is low if less than 20% of radio

Configuration Reason

resources are occupied.

Configuration Rule and


Adjustment Suggestion

The higher the value is, the more likely the cell will be to be selected by
the RNC as the target cell for re-direction.
NRTThs_0>NRTThs_1>NRTThs_2

Change Mode

Offline

Related features

None

Related Parameters

[BSC]IurgSupport

Relationship

This parameter becomes valid when IurgSupport is set to Yes.

Related Interfaces

Iur-g

Impact on Equipment

Impact on service

0
2-66

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork->BSC Managed Element->Config SetBSC
Function->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.23 On demand mode switch of information exchange


(IurgSwitchGroup_0)
Full Name

On demand mode switch of information exchange

Abbreviation

IurgSwitchGroup_0

3GPP Name

None

3GPP Reference

None
This parameter decides whether to enable On Demand mode of information exchange. Information exchange refers to the process in which
the RNC and the BSC exchange the capacity information of radio cell
resources. On Demand is a mode in which the information is reported

Description

immediately when being requested for.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

On Demand is one of the typical information exchange modes, so the

Configuration Reason

default value is Yes.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]IurgSupport

Relationship

This parameter becomes valid when IurgSupport is set to Yes.

Related Interfaces

Iur-g

Impact on Equipment

Impact on service

0
2-67

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config
Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.24 On modification mode switch of information exchange


(IurgSwitchGroup_1)
Full Name

On modification mode switch of information exchange

Abbreviation

IurgSwitchGroup_1

3GPP Name

None

3GPP Reference

None
This parameter decides whether to enable On Modification mode of information exchange. Information exchange refers to the process in which
the RNC and the BSC exchange the capacity information of radio cell resources. On Modification is a mode in which the information is reported

Description

immediately when it changes.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

On Modification is one of the typical information exchange modes, so

Configuration Reason

the default value is Yes.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]IurgSupport

Relationship

This parameter becomes valid when IurgSupport is set to Yes.

Related Interfaces

Iur-g

Impact on Equipment

Impact on service

0
2-68

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config
Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.25 On demand mode switch of common measurement


(IurgSwitchGroup_2)
Full Name

On demand mode switch of common measurement

Abbreviation

IurgSwitchGroup_2

3GPP Name

None

3GPP Reference

None
This parameter decides whether to enable On Demand mode of common
measurement. Common measurement refers to the process in which the
RNC and the BSC exchange the occupation information of radio cell resources. On Demand is a mode in which the information is reported im-

Description

mediately when being requested for.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

On Demand is one of the typical common measurement modes, so the

Configuration Reason

default value is Yes.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]IurgSupport

Relationship

This parameter becomes valid when IurgSupport is set to Yes.

Related Interfaces

Iur-g

Impact on Equipment

Impact on service

0
2-69

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config
Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.26 Periodic mode switch of common measurement


(IurgSwitchGroup_3)
Full Name

Periodic mode switch of common measurement

Abbreviation

IurgSwitchGroup_3

3GPP Name

None

3GPP Reference

None
This parameter decides whether to enable Periodic mode of common
measurement. Common measurement refers to the process in which the
RNC and the BSC exchange the occupation information of radio cell resources. Periodic is a mode in which the information is reported periodi-

Description

cally.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

Periodic is one of the typical common measurement modes, so the

Configuration Reason

default value is Yes.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]IurgSupport

Relationship

This parameter becomes valid when IurgSupport is set to Yes.

Related Interfaces

Iur-g

Impact on Equipment

Impact on service

0
2-70

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config
Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.27 Immediate assignment repeat (ImmAssRep)


Full Name

Immediate assignment repeat

Abbreviation

ImmAssRep

3GPP Name

None

3GPP Reference

None
This parameter indicates whether to re-send the immediate assignment
message. If it is set to 0, the message will not be re-sent. If it is set to 1,

Description

the message will be re-sent once.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The message is re-sent once.

Configuration Rule and

Enabling this parameter has positive effect on the success rate of

Adjustment Suggestion

immediate assignments.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-71
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.28 Immediate assignment priority (ImmAssPrio)


Full Name

Immediate assignment priority

Abbreviation

ImmAssPrio

3GPP Name

None

3GPP Reference

None
This parameter indicates the priority of the immediate assignment message. The value range is 0 and 1. The value 1 stands for high priority
at which any PCH block can be preempted. Currently, this parameter is

Description

invalid and the value is fixed to 1.

Managed Object

BSC
0: Low, indicating low priority

Value Range and Step

1: High, indicating high priority

Unit

None

Default Value

High

Default Value
Configuration Reason

The default value is fixed to 1 for the BTS.

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others
2-72

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.3.29 Paging repeat number (PagRep)


Full Name

Paging repeat number

Abbreviation

PagRep

3GPP Name

None

3GPP Reference

None
This parameter indicates how many times a paging message will be

Description

re-sent. 0: Indicates no resending; 1-4: Indicate the times of re-sending

Managed Object

BSC
0..4

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The message is re-sent once.


The higher the value is, the more likely the MS is to be paged. In this

Configuration Rule and

case, however, the load of the paging channel will increase, so you

Adjustment Suggestion

should consider both the load of the paging channel and the success
rate of the paging when setting this parameter.

Change Mode

Offline

Related features

ZGB-02-01-001 Paging

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

None
2-73

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

2.3.30 Timer of waiting for IPGB changing over (TIPGBChgWait)


Full Name

Timer of waiting for IPGB changing over

Abbreviation

TIPGBChgWait

3GPP Name

None

3GPP Reference

None
This parameter is a timer that records the time of the IPGB in waiting for
handover when the service initiates an IPGB board handover.
Enable condition: When all the NSVC states of the IPGB board are
not normal, the service can initiate active/standby handover based on
judgment.
Disable condition: Some NSVC states recover.

Description

Timeout: The service initiates active/standby handover.

Managed Object

BSC

Value Range and Step

6..600

Unit

Default Value

60

Default Value

Try to avoid the impact of instant NSVC break or connection, and

Configuration Reason

long-time wait.
This parameter cannot be configured too low, so as to avoid the

Configuration Rule and


Adjustment Suggestion

impact of instant NSVC break or connection. This parameter cannot


be configured too high, so as to avoid long-time wait when the service
initiates the IPGB handover.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


Set ID->BSC Function ID->Others

2-74
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.3.31 restricted time after continuous IPGB changing over


(TIPGBConChglmt)
Full Name

restricted time after continuous IPGB changing over

Abbreviation

TIPGBConChglmt

3GPP Name

None

3GPP Reference

None
This parameter is a timer that records the restricted time for continuous
IPGB handovers.
Enable condition: The service requires active/standby handover but the
number of continuous IPGB handovers reaches the upper threshold.
Disable condition: None
Timeout: The number of continuous IPGB active/standby handovers

Description

is cleared.

Managed Object

BSC

Value Range and Step

600..65535

Unit

Default Value

3600

Default Value

Try to avoid frequent handovers in case of unreachable NSVC links on

Configuration Reason

the active and standby IPGB boards.

Configuration Rule and


Adjustment Suggestion

In normal cases with IPGB links, use the recommended value. In the
case of unstable IPGB link, configure this parameter to a larger value, so
as to avoid frequent handovers in case of unreachable NSC links.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-75
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


Set ID->BSC Function ID->Others

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.3.32 Info_3
Full Name

Info_3

Abbreviation

Info_3

3GPP Name

None

3GPP Reference

None

Description

This parameter is currently not used.

Managed Object

BSC

Value Range and Step

0..4294967295

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is currently not used.

Configuration Rule and


Adjustment Suggestion

This parameter is currently not used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


set ID->BSC Function ID->Others

Parameter Modifying
Version

iBSCV6.20.711c

Parameter Modifying
Detail

New
2-76

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.3.33 Info_6
Full Name

Info_6

Abbreviation

Info_6

3GPP Name

None

3GPP Reference

None

Description

This parameter is currently not used.

Managed Object

BSC

Value Range and Step

0..4294967295

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is currently not used.

Configuration Rule and


Adjustment Suggestion

This parameter is currently not used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


set ID->BSC Function ID->Others

Parameter Modifying
Version

iBSCV6.20.711c

Parameter Modifying
Detail

New

2.3.34 Threshold of UPUDSP Dynamic Adjustment (Info_7)


Full Name

Threshold of UPUDSP Dynamic Adjustment

Abbreviation

Info_7

3GPP Name

None

3GPP Reference

None
2-77

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The threshold may affect the traffic balance after the UPUDSP dynamic
Description

adjustment.

Managed Object

BSC

Value Range and Step

1..100

Unit

None

Default Value

10

Default Value
Configuration Reason

Theoretically, if the threshold is set to 10, the traffic balance will be better.
The R_BSC.INFO[7] is used as the adjustment threshold for UPUDSP.

Configuration Rule and

The default value is 10. The value ranges from 1 to 100. Generally, the

Adjustment Suggestion

lower the threshold, the better balance of the DSP load. The default
value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


set ID->BSC Function ID->Others

Parameter Modifying
Version

iBSCV6.20.711c

Parameter Modifying
Detail

New

2.4 Channel Allocation Control Parameters


2.4.1 Dynamic HR support indication (DynaHREnable)
Full Name

Dynamic HR support indication

Abbreviation

DynaHREnable

3GPP Name

None

3GPP Reference

None

2-78
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

This parameter decides whether the BSC supports dynamic HR. The dynamic HR channel allocation function enables the network to allocate
full-rate or half-rate channels to MSs according to the traffic in the cell
when it allocate channels for the MSs. Allocating half-rate channels when
the channels in the cell are likely to be congested minimizes the duration
Description

of possible congestions in peak hours.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

The dynamic HR function of the BSC cannot be enabled unless this

Adjustment Suggestion

switch is enabled.

Change Mode

Offline

Related features

ZGO-03-02-005 Dynamic Half Rate Allocation

Related Parameters

[Cell]DynaHREnable

Relationship

Full-rate channels can be converted to half-rate channels only when the


BSC-level and cell-level DynaHREnable is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Channel Allocation Control parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.4.2 HR channel fragment repackaging support (HRDfragSupport)


Full Name

HR channel fragment repackaging support

Abbreviation

HRDfragSupport

3GPP Name

None

2-79
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

None
This parameter is a switch to support the HR channel defragmentation
function and can be configured on both BSCs and cells. The HR channel
defragmentation function is enabled only when both BSC- and cell-level
switches are enabled and the proportion of the idle TCH/Fs in these cells is
not more than the threshold proportion of the TCH/Fs to the total available

Description

service channels in the cell where the defragmentation is enabled.

Managed Object

BSC
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

0: No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


Enabling the HR channel defragmentation function in a cell where
dynamic half rate is used can increase full-rate channels and improve

Configuration Rule and

voice quality. Enabling the function on dynamic channels can increase

Adjustment Suggestion

available PS channels. The function can be enabled as needed. If it is


enabled, the corresponding switch in cell parameters must be enabled at
the same time. In this case, more handovers will occur in cells.

Change Mode

Offline

Related features

ZGO-03-02-004 HR Concentration

Related Parameters

[BSC]HoIntraEnable
[Cell]HRDfragSupport

Relationship

This function can be enabled only when HoIntraEnable and BSC- and
cell-level HRDfragSupport in the system control parameters are enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Channel Allocation Control parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-80
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.4.3 User priority for EMLPP (PriThreshold)


Full Name

User priority for EMLPP

Abbreviation

PriThreshold

3GPP Name

None

3GPP Reference

None
When you enable the eMLPP service function, which allows high-priority
users to access channels first, the system can reserve a certain number
of channels for high-priority users (currently, only full-rate TCHs can be
reserved channels)
When the CS instance invokes the database to request channels,
the user's PriorityLevel information will be sent to the database and
compared with the value of PriThreshold in the BSC table. If PriorityLevel
is not more than PriThreshold (That is to say, the priority of the user is
not lower than PriThreshold. The lower the priority value is, the higher

Description

the priority will be. ), reserved channels can be used.

Managed Object

BSC
1..15

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default value "2" is suitable for most applications.

Configuration Rule and


Adjustment Suggestion

You can adjust this parameter as needed.

Change Mode

Offline

Related features

ZGO-01-03-001 Emlpp

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Channel Allocation Control parameters

Parameter Modifying
Version

None

2-81
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

2.4.4 Preferred speech version (half) (PreferSpeechVer H)


Full Name

Preferred speech version (half)

Abbreviation

PreferSpeechVer H

3GPP Name

None

3GPP Reference

None
This parameter indicates the preferred half-rate speech version in the CS
channel allocation. Half rate version1 refers to HR and version3 refers to

Description

AMR.

Managed Object

BSC
0: No preferred version.
1: Half rate version1.

Value Range and Step

3: Half rate version3.

Unit

None

Default Value

0: No preferred version.

Default Value

No preferred version is specified at the BSC side. Instead, the MSC

Configuration Reason

coding strategy is used.


It is recommended to use the default value and allow the MSC to decide
the speech version unless otherwise necessary.
If you modify the default value, the new value will decide the speech

Configuration Rule and


Adjustment Suggestion

version.
Generally, AMR enables the adaptive switching of coding rates. In
poor channel conditions, increasing the channel coding rate (increasing
redundant bits) and reducing the source (speech) coding rate can
ensure the conversation quality. In good channel conditions, increasing
the source coding rate can improve the voice quality.

Change Mode

Offline

Related features

ZGO-01-01-001 Half Rate

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
2-82

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Channel Allocation Control parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.4.5 Preferred speech version (full) (PreferSpeechVer F)


Full Name

Preferred speech version (full)

Abbreviation

PreferSpeechVer F

3GPP Name

None

3GPP Reference

None
This parameter indicates the preferred full-rate speech version in the CS
channel allocation. Full rate version1 refers to FR. Full rate version2 refers

Description

to EFR and version3 refers to AMR.

Managed Object

BSC
0: No preferred version.
1: Full rate version1.
2: Full rate version2.

Value Range and Step

3: Full rate version3.

Unit

None

Default Value

0: No preferred version.

Default Value

No preferred version is specified at the BSC side. Instead, the MSC

Configuration Reason

coding strategy is used.


It is recommended to use the default value and allow the MSC to decide
the speech version unless otherwise necessary.
If you modify the default value, the new value will decide the speech
version.

Configuration Rule and

Generally, ERF can provide the best voice quality and user satisfaction.

Adjustment Suggestion

AMR enables the adaptive switching of coding rates. In poor channel


conditions, increasing the channel coding rate (increasing redundant
bits) and reducing the source (speech) coding rate can ensure the
conversation quality. In good channel conditions, increasing the source
coding rate can improve the voice quality.

Change Mode

Offline

Related features

ZGB-01-01-001 Full Rate (FR) Speech Codec

2-83
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Channel Allocation Control parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.4.6 Reserved channel first (RsvChanFirst)


Full Name

Reserved channel first

Abbreviation

RsvChanFirst

3GPP Name

None

3GPP Reference

None
This parameter indicates the order of preference of reserved and
non-reserved channels. If this functional switch is enabled, reserved
channels will be allocated to high-priority users first.
Yes: To allocate reserved channels first

Description

No: To allocate non-reserved channels first

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value

Generally, reserved channels are used first to avoid the waste of channel

Configuration Reason

resources.

Configuration Rule and


Adjustment Suggestion

The default value is recommended unless otherwise necessary.

Change Mode

Offline

Related features

ZGO-01-03-001 Emlpp

2-84
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Channel Allocation Control parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.4.7 EMLPP channel reserved rate (EMLPPThs)


Full Name

EMLPP channel reserved rate

Abbreviation

EMLPPThs

3GPP Name

None

3GPP Reference

None
This parameter decides the proportion of channels reserved for high-priority users when you enable the eMLPP service function, which allows

Description

high-priority users to access channels first.

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

Default Value

Default Value
Configuration Reason

This is a characteristic parameter and no channel is reserved by default.


The higher the value is set to, the more channels will be reserved. In

Configuration Rule and


Adjustment Suggestion

this case, high-priority users are more likely to access a channel, but
low-priority users have fewer available channels.
The lower the value is set to, the fewer channels will be reserved. In this
case, high-priority users are less likely to access a channel.

Change Mode

Offline

Related features

ZGO-01-03-001 Emlpp
2-85

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

[Cell]EMLPPThs
If the parameter UseCelleMLPPThs is enabled, the cell-level parameter

Relationship

EMLPPThs should be enabled. If not, the BSC-level parameter


EMLPPThs should be enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Channel Allocation Control parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.4.8 TrxPSBusyThs (TrxPSBusyThs)


Full Name

TrxPSBusyThs

Abbreviation

TrxPSBusyThs

3GPP Name

None

3GPP Reference

None
The degree of idleness of the PS service channels on a carrier is
calculated as follows:
If there are available uplink and downlink PS service channels on the
carrier, and if the number of available uplink channels is byUpNum and
the number of available downlink channels is byDwNum,
Total degree of idleness of all available uplink PS service channels =
100*(Abis/AbisMax)*(Qos/16)*((Usermax-Usernum)/Usermax)
In this formula, the degrees of idleness of byUpNum uplink channels
are accumulated.
Total degree of idleness of all available downlink PS service channels =
100*(Abis/AbisMax)*(Qos/16)*((Usermax-Usernum)/Usermax)
In this formula, the degrees of idleness of byDwNum downlink
channels are accumulated.
Where,
Abis is the number of Abis resources (IP Abis bandwidth or E1 Abis
timeslot) allocated to the channels.
AbisMax is the maximum number of Abis resources (IP Abis bandwidth

Description

or E1 Abis timeslot) that can be allocated to the channels. For example,


2-86

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

at most four E1 Abis timeslots can be allocated to a PS service channel


on the EDGE carrier. 4
QoS is the number of available QoS quotas on the channels (the original
number is 16.)
Usermax is the maximum allowable number of users whose data is
multiplexed on the channels.
Usernum is the number of users on the current channel.
The degree of idleness of the carriers (TrxIdle, ranging from 0 to 100) is
calculated as follows:
If byUpNum == 0 and byDwNum != 0, TrxIdle = Total degree of idleness
of all available downlink PS service channels / byDwNum
If byUpNum != 0 and byDwNum == 0, TrxIdle = Total degree of idleness
of all available uplink PS service channels / byUpNum
If byUpNum != 0 and byDwNum != 0, TrxIdle = (Total degree of idleness
of all available downlink PS service channels * byDwNum + Total degree
of idleness of all available uplink PS service channels * byUpNum) / (2
* byDwNum * byUpNum)
If byUpNum == 0 and byDwNum == 0, TrxIdle = 0 (This is because there
are no available uplink or downlink PS service channels on the carriers. )
TRX controlled only by the degree of idleness of PS service channels is
selected according to the following principles:
If there are idle PS service channels on all TRXs, one TRX will be
selected and allocated at random. As long as the degree of idleness of
the PS service channels on the TRX is higher than the threshold, the
same TRX is always selected as a priority for the purpose of centralized
service allocation.
When the degree of idleness of the PS service channels on the TRX is
lower than the threshold, it is deemed that the TRX is overloaded with
PS services and an inter-TRX balance is required. In this case, another
idle TRX will be selected and new PS services will be allocated to the
TRX until it is overloaded.
3When all TRXs are overloaded with PS services, the TRX with higher
degree of idleness of PS service channels will be selected for the
purpose of inter-TRX balance of PS services.
Managed Object

BSC
1..100

Value Range and Step

Step: 1

Unit

Default Value

50
When the default value is set to 50, PFC users occupy half channel Qos.

Default Value

For non-PFC users, the number of current users on the channels is half

Configuration Reason

the maximum number of users. In this way, the channel expansion is


controlled within a reasonable speed.
2-87

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

When there are sufficient PS channel resources and high rates are
Configuration Rule and

required for PS services, you can set this parameter to a lower value to

Adjustment Suggestion

expand the PS service channels to new carriers as quickly as possible.


Otherwise, set it to a higher value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Channel Allocation Control parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.4.9 Resource pool for PS rate (PsAbisThs)


Full Name

Resource pool for PS rate

Abbreviation

PsAbisThs

3GPP Name

None

3GPP Reference

None
This parameter indicates the upper limit of the rate of the Abis resources
that can be allocated to PS services in the full-dynamic Abis resource
pool. If this threshold value is exceeded, no Abis resources will be
allocated to PS services even when there are available Abis resources.
Rate of occupied PSABIS resources = Abis resources allocated to PS

Description

services / Total available Abis resources in the resource pool

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

Default Value

80

2-88
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

Setting this parameter to "80" allows Abis resources to be allocated


evenly to PS and CS services. In this case, CS services are given a
certain degree of priority.
If the PS traffic in the cell is high, you can set a higher value not more
than 90. If the PS traffic is low and there is a shortage of Abis resources,
you can lower the value appropriately to ensure CS services first.

Change Mode

Offline

Related features

ZGO-03-03-001 Full Dynamic Abis Allocation

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Channel Allocation Control parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.4.10 Extended uplink dynamic allocation support


(ExUpDynSupport)
Full Name

Extended uplink dynamic allocation support

Abbreviation

ExUpDynSupport

3GPP Name

EXTENDED_DYNAMIC_ALLOCATION
TS44.060: "Radio Link Control/Medium Access Control (RLC/MAC) pro-

3GPP Reference

tocol"
This parameter indicates whether the cell supports extended uplink dynamic allocation. When this function is used, the MS can decide whether
to send uplink blocks in all of the allocated uplink timeslots by only mon-

Description

itoring the USF allocation in the lowest timeslot.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None
2-89

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

No

Default Value

The default value is set according to the traffic model and resource

Configuration Reason

occupation in the network.

Configuration Rule and


Adjustment Suggestion

When the MS supports this function and the uplink PS service


transmission is a priority or there are sufficient uplink radio resources,
enabling the function can increase the uplink transmission rate.

Change Mode

Offline

Related features

ZGO-03-02-007 Extended Dynamic Allocation

Related Parameters

[Cell]ExUpDynSupport

Relationship

This parameter is valid when the cell-level ExUpDynSupport parameter


is enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Channel Allocation Control parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5 Timer 1
2.5.1 Blocking/Unblocking period (T1)
Full Name

Blocking/Unblocking period

Abbreviation

T1

3GPP Name

T1

3GPP Reference

3GPP TS 48.008 V5.12.0

2-90
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

This parameter is timer T1, which specifies a time period during which
the BSS needs to initiate a block/unblock a ground circuit process due to
some reasons, such as O&M intervene, equipment failure or restoration,
or radio resource available or unavailable. In the process, the BSS
sends a BLOCK/UNBLOCK message to the MSC. Upon receiving this
message, the MSC returns a BLOCK/UNBLOCK ACK message to the
BSS.
Start: A single circuit block/unblock message is sent to the MSC.
Stop: A single circuit block/unblock acknowledgement message is
received from the MSC.
At expiry: If the number of times that no acknowledgement message is
received from the MSC does not exceed the maximum number, the BSC
sends a single circuit block/unblock message to the MSC again. If the
number of times that no acknowledgement is received from the MSC
Description

exceeds the maximum number, the instance is terminated.

Managed Object

BSC
30..150

Value Range and Step

Step: 1

Unit

100 ms

Default Value

80

Default Value
Configuration Reason

Generally, an acknowledgement message can be received in eight


seconds after the BSC sends a circuit block/unblock message to the
MSC.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

2-91
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

2.5.2 Global resetting period (T4)


Full Name

Global resetting period

Abbreviation

T4

3GPP Name

T4

3GPP Reference

3GPP TS 48.008 V5.12.0


This parameter is timer T4, which is used to supervise the BSSAP
RESET message sent from the BSC to the MSC.
Start: The BSC initiates a global reset process.
Stop: A BSSAP RESET ACK message is received from the MSC.

Description

At expiry: The BSC repeats the whole process.

Managed Object

BSC
60..150

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value

Generally, an acknowledgement message can be received in 10

Configuration Reason

seconds after the BSC sends a reset message to the MSC.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

2-92
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Detail

None

2.5.3 Protective period for global resetting (T13)


Full Name

Protective period for global resetting

Abbreviation

T13

3GPP Name

T13

3GPP Reference

3GPP TS 48.008 V5.12.0


This parameter is timer T13, which specifies the protection time for
a local call clear process.
Start: When the BSC receives a BSSAP RESET message from the MSC.
Stop: When an SSP/SPI (SubSystem Prohibited/Signalling Point
Inhibited) message is received from the SCCP.

Description

At expiry: The BSS sends a BSSAP RESET ACK message to the MSC.

Managed Object

BSC
30..60

Value Range and Step

Step: 1

Unit

100 ms

Default Value

40

Default Value

Generally, the BSC can receive a message from the SCCP in four

Configuration Reason

seconds.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None
2-93

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

2.5.4 Circuit resetting period on BSS side (T19)


Full Name

Circuit resetting period on BSS side

Abbreviation

T19

3GPP Name

T19

3GPP Reference

3GPP TS 48.008 V5.12.0


This parameter is timer T19, which indicates the time period of a circuit
reset process on the BSS side.
Start: The BSS sends a BSSAP CIRCUIT RESET message to the
MSC for forcibly releasing the circuit due to an exception of BSC SCCP
connection.
Stop: Upon receiving the BSSAP CIRCUIT RESET message, the MSC
releases the related services and the circuit becomes idle. Then the
MSC sends a BSSAP CIRCUIT RESET ACK message to the BSC. The
timer is stopped when the BSC receives the RESET CIRCUIT ACK
message.
At expiry: If the number of timer expiries is less than the maximum
number of times that the BSSAP CIRCUIT RESET message is sent,
the BSC sends this message to the MSC again. If the number of timer
expiries reaches the maximum number, the BSC reports the reset failure

Description

to the O&M, and then terminates the process and clears the instance.

Managed Object

BSC
30..150

Value Range and Step

Step: 1

Unit

100 ms

Default Value

80

Default Value
Configuration Reason

Generally, an acknowledgement message can be received in eight


seconds after the BSC sends a BSSAP CIRCUIT RESET message to
the MSC.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None
2-94

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.5 Circuit group blocking/unblocking period (T20)


Full Name

Circuit group blocking/unblocking period

Abbreviation

T20

3GPP Name

T20

3GPP Reference

3GPP TS 48.008 V5.12.0


This parameter specifies a time period during which the BSS initiates a
circuit group block/unblock process due to some reasons, such as O&M
intervene, equipment failure or restoration, or radio resource available or
unavailable. In this process, the BSS sends a BSSAP CIRCUIT GROUP
BLOCK/UNBLOCK message to the MSC. Upon receiving this message,
the MSC returns a BSSAP CIRCUIT GROUP BLOCK/UNBLOCK ACK
message to the BSS, informing the BSS that it has received the BSSAP
CIRCUIT GROUP BLOCK/UNBLOCK message.
Start: A BSSAP CIRCUIT GROUP BLOCK/UNBLOCK message is sent
to the MSC.
Stop: A BSSAP CIRCUIT GROUP BLOCK/UNBLOCK ACK message
is received from the MSC.
At expiry: If the number of times that no acknowledgement message is
received from the MSC does not exceed the maximum number, the
BSC sends the BSSAP CIRCUIT GROUP BLOCK/UNBLOCK message
again. If the number of times that no acknowledgement is received from

Description

the MSC exceeds the maximum number, the instance is terminated.

Managed Object

BSC
30..150

Value Range and Step

Step: 1

Unit

100 ms

2-95
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Default Value
Configuration Reason

80
Generally, an acknowledgement message can be received in
eight seconds after the BSC sends a BSSAP CIRCUIT GROUP
BLOCK/UNBLOCK message to the MSC.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.6 RLSD message receive protection timer (T9101)


Full Name

RLSD message receive protection timer

Abbreviation

T9101

3GPP Name

None

3GPP Reference

None
This parameter is timer T9101.
Start: When the BSC sends a BSSAP CLEAR COMPLETE message
to the MSC.
Stop: When an RLSD message is received from the MSC.
At expiry: The BSC sends an RLSD message to release the SCCP

Description

connection.

Managed Object

BSC
20..50

Value Range and Step

Step: 1

2-96
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Unit

100 ms

Default Value

20

Default Value

Generally, the BSC can receive a message from the MSC in two

Configuration Reason

seconds.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.7 Channel activation protection timer (RmsT9103)


Full Name

Channel activation protection timer

Abbreviation

RmsT9103

3GPP Name

None

3GPP Reference

None
This parameter is timer T9103, which is used to supervise the channel
activation process.
Start: When the BSC sends a CHANNEL ACTIVATION message to
the BTS.
Stop: When the BSC receives a CHANNEL ACTIVATION ACK or
CAHNNEL ACTIVATION NACK message from the BTS.
At expiry: The BSC sends an RF CHANNEL RELEASE message to

Description

the BTS.

Managed Object

BSC

2-97
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Value Range and Step

20

Unit

100 ms

Default Value

20

Default Value

Generally, the CHANNEL ACTIVATION ACK message can be received

Configuration Reason

from the BTS in two seconds.

Configuration Rule and


Adjustment Suggestion

Only the default value can be used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.8 MSC clear command protection timer (T9104)


Full Name

MSC clear command protection timer

Abbreviation

T9104

3GPP Name

None

3GPP Reference

None
This parameter is timer T9104, which is used to supervise the CLEAR
COMMAND sent from the MSC.
Start: When the BSC sends a CLEAR REQUEST message to the MSC.
Stop: When a CLEAR COMMAND message is received from the MSC.
At expiry: The BSC sends the CLEAR REQUEST again. The number of

Description

times that the CLEAR REQUEST message is sent cannot exceed four.

Managed Object

BSC

2-98
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

20..50
Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value

Generally, the CLEAR COMMAND message can be received from the

Configuration Reason

MSC in three seconds.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.9 SCCP connection protection timer (T9105)


Full Name

SCCP connection protection timer

Abbreviation

T9105

3GPP Name

None

3GPP Reference

None
This parameter is timer T9105, which is used to supervise the SCCP
connection process.
Start: When the BSC sends a SCCP CONNECTION REQ message
to the MSC.
Stop: When the BSC receives a SCCP CONNECTION CONFIRM or
SCCP CONNECTION REFUSED message from the BTS.

Description

At expiry: The BSC sends a CHANNEL RELEASE message to the MS.

2-99
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

BSC
20..60

Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value

Generally, the SCCP CONNECTION CONFIRM or SCCP CONNECTION

Configuration Reason

REFUSED message can be received from the MSC in three seconds.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.10 Protective time waiting for access (RmsT1)


Full Name

Protective time waiting for access

Abbreviation

RmsT1

3GPP Name

None

3GPP Reference

None

2-100
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

This parameter is timer RmsT1, which specifies the protection time used
to wait for the access of the MS after the channel activation in the case
of assignment or handover.
Start: When the target channel sends a RADIO AVAILABLE message to
the source channel after receiving the CHL ACITIVATION ACK message.
Stop: The target channel receives an ASSIGNMENT COM or
HANDOVER COM message after the MS is accessed.
Description

At expiry: Release the target channel instance.

Managed Object

BSC
0..1000

Value Range and Step

Step: 1

Unit

100 ms

Default Value

70

Default Value
Configuration Reason

Generally, the MS can be accessed in seven seconds.

Configuration Rule and

cause long-time occupation of radio resources, which results in the

Adjustment Suggestion

waste of resources. A too small parameter value may increase the

The default value is recommended. A too large parameter value will

access failure rate.


Change Mode

Offline

Related features

None

Related Parameters

[BSC]rmsT3107
[BSC]rmsT3103

Relationship

For intra-cell handovers, RmsT1 (7s) > RmsT3107 (6s)


For inter-cell handovers, RmsT1 (7s) > RmsT3103 (6s)

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-101
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.5.11 Protection time for applying to channel (RmsT2)


Full Name

Protection time for applying to channel

Abbreviation

RmsT2

3GPP Name

None

3GPP Reference

None
This parameter is timer T2, which indicates the protection time for TCH
application when an assignment request is received from the A interface
or an intra-cell handover is initiated.
Start: An assignment request is received from the A interface or an
intra-cell handover is initiated.
Stop: The TCH activation succeeds. The TCH activation fails. Or the
TCH request is placed on the queue after request failure.
At expiry:
An assignment failure message is sent to the MSC in the case of
assignment request.
The service is shifted back to the source channel in the case of handover

Description

request.

Managed Object

BSC
20..50

Value Range and Step

Step: 1

Unit

100 ms

Default Value

40

Default Value

Generally, a request success or failure message can be received in

Configuration Reason

four seconds.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

2-102
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.12 Protection time for link establishment response (RmsT3)


Full Name

Protection time for link establishment response

Abbreviation

RmsT3

3GPP Name

None

3GPP Reference

None
This parameter is timer T3, which indicates the protection time for an
A interface link establishment response in an immediate assignment
process.
Start: The BSC sends an ESTABLISH IND message for immediate
assignment.
Stop: The BSC receives an A interface link establishment
acknowledgement message.

Description

At expiry: Release the service.

Managed Object

BSC
30..100

Value Range and Step

Step: 1

Unit

100 ms

Default Value

60

Default Value
Configuration Reason

Generally, six seconds are enough for protection.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-103
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.13 Protective time that P0 confirms the message HO/ASS COM


(RmsT4)
Full Name

Protective time that P0 confirms the message HO/ASS COM

Abbreviation

RmsT4

3GPP Name

None

3GPP Reference

None
This parameter is timer T4, which indicates the protection time for the
OMP to acknowledge the HO COM or ASS COM message.
Start: The BSC receives an HO COM or ASS COM message from the
MS.
Stop: The BSC receives an acknowledgement on the HO COM or ASS
COM message.

Description

At expiry: Release the service.

Managed Object

BSC
10..80

Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value
Configuration Reason

Generally, three seconds are enough.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

2-104
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.14 Encryption mode modification time (RmsT5)


Full Name

Encryption mode modification time

Abbreviation

RmsT5

3GPP Name

None

3GPP Reference

None
This parameter is timer T5, which is used to supervise the cipher mode
modify process, that is, wait for a response from the MS after the radio
cipher mode is set.
Start: When the BSC receives a CIPHER MODE COMMAND message
from the MSC.
Stop: When the BSC receives a CIPHER MODE COMPLETE message
from the MS.
At expiry: A BSSAP CIPHER MODE REJECT message is sent to the

Description

MSC.

Managed Object

BSC
30..120

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value

Generally, the CIPHER MODE COMPLETE message can be received

Configuration Reason

from the MS in 10 seconds.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None
2-105

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.15 SAPI3 link establishment time (RmsT6)


Full Name

SAPI3 link establishment time

Abbreviation

RmsT6

3GPP Name

None

3GPP Reference

None
This parameter is timer T6, which is used to supervise the establishment
of SAPI3 link.
Start: When the BSC receives a DTAP (SAPI=3) message from the
MSC, and no SAPI3 link exists.
Stop: When the BSC receives a ESTABLISH CONFIRM message from
the BTS.

Description

At expiry: Send a BSSMAP SAPI"n"REJECT message to the MSC.

Managed Object

BSC
10..300

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value

Generally, the ESTABLISH CONFIRM message can be received from

Configuration Reason

the BTS in 10 seconds.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

2-106
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.16 External handover protective time (RmsT8)


Full Name

External handover protective time

Abbreviation

RmsT8

3GPP Name

None

3GPP Reference

None
This parameter is timer RmsT8, which is used to supervise the external
handover process.
Start: When the BSC sends an external handover command.
Stop: When the BSC receives an HO COMCLEAR CMD (handover
success) or UM HO FAIL (handover failure) message.

Description

At expiry: Release the service.

Managed Object

BSC
1..1000

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Generally, an external handover can be completed in 10 seconds.


The default value is recommended. If the external handover success
rate is low, increase the parameter value. However, a too large
parameter value will impact the user experience.

Change Mode

Offline

Related features

None

2-107
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.17 Protective time for No.7 signal instantaneous disconnection


(T3)
Full Name

Protective time for No.7 signal instantaneous disconnection

Abbreviation

T3

3GPP Name

None

3GPP Reference

None
This parameter is timer T3, which specifies a delay to avoid improper
actions caused by transient interruption of signallings.
A global reset is initiated when the interruption time of SS7 signallings
exceeds the protection time specified by timer T3. The SS7 signalling
link is deemed as broken if no signalling point reachable event is
received in the delay duration, and a global reset is initiated. If the
signalling point reachable event is received in the delay duration, it is
deemed that transient interruption of the SS7 link occurs.
Start: The periodic detection of MSC office status is interrupted. Or an
MSC/SLMC/iTC reset message is received.
Stop: An MSC reachable message is received from the MSC.
At expiry: If the opposite office is unreachable, clear the opposite office
block field and the opposite office un-equipped field, and send an MSC

Description

RESET message to the global reset process.

Managed Object

BSC
10..200

Value Range and Step

Step: 1

2-108
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Unit

100 ms

Default Value

100
Generally, it is deemed that a transient interruption of SS7 signalling

Default Value

link occurs when the failed SS7 signalling link restores in 10 seconds.

Configuration Reason

The global reset is not needed in the case of transient interruption of


SS7 signalling link.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.18 Protective time that PO responses external handover


completion message (RmsT7)
Protective time that PO responses external handover completion mesFull Name

sage

Abbreviation

RmsT7

3GPP Name

T7

3GPP Reference

3GPP TS 48.008 V5.12.0


This parameter is RmsT7, which specifies the protection time for the
OMP to acknowledge an assignment or handover complete message.
Start: The BSC sends a handover request.
Stop: The BSC receives the HO CMD message.

Description

At expiry: Impose penalty to the external cell and terminate the process.

2-109
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

BSC
50..200

Value Range and Step

Step: 1

Unit

100 ms

Default Value

150

Default Value
Configuration Reason

Generally, an external handover can be completed in 15 seconds.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.19 HBTS scan begin time (HBTSScanBT)


Full Name

HBTS scan begin time

Abbreviation

HBTSScanBT

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the starting time of the S8001 frequency scan.

Managed Object

BSC
0..23

Value Range and Step

Step: 1

Unit

None
2-110

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Default Value

3 (indicating three o'clock)

Default Value

Generally, the traffic is small at three o'clock in the morning, when the

Configuration Reason

scan has the minimum effect on the system.

Configuration Rule and


Adjustment Suggestion

The default value is recommended. According to the actual network


conditions, you can also set this parameter to the time when the traffic
is the smallest.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]HBTSScanSiteNum

Relationship

If HBTSScanSiteNum is set to 0, this parameter is configurable but


invalid.

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.20 HBTS scan cycle (HBTSScanCyc)


Full Name

HBTS scan cycle

Abbreviation

HBTSScanCyc

3GPP Name

None

3GPP Reference

None
This parameter indicates the period of the S8001 frequency scan.
Start: A new periodic frequency calibration message is received and a
calibration is started.

Description

Stop: The old periodic frequency calibration message is killed.

Managed Object

BSC
1..255

Value Range and Step

Step: 1

Unit

3600s

2-111
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

24

Default Value
Configuration Reason

By default, the scan is carried out once per 24 hours.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]HBTSScanSiteNum

Relationship

If HBTSScanSiteNum is set to 0, this parameter is configurable but


invalid.

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.21 IP ABIS Pool Band Width Push Down Protection


(TBWPushDown)
Full Name

IP ABIS Pool Band Width Push Down Protection

Abbreviation

TBWPushDown

3GPP Name

None

3GPP Reference

None
This parameter is a protection timer for decreasing bandwidth of some
channels when the bandwidth resources are not enough. If the time since
the previous bandwidth decreasing is shorter than the time specified by

Description

this timer, no bandwidth decreasing is allowed.

Managed Object

BSC
1..10

Value Range and Step

Step: 1

Unit

2-112
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Default Value
Default Value
Configuration Reason

5
The default value is set to avoid frequent decreasing of bandwidth. Five
seconds are appropriate because the bandwidth is reported for five
times in this period.
The default value is recommended.

Configuration Rule and


Adjustment Suggestion

1) Decreasing the parameter value results in bandwidth decreasing at a


high frequency.
2) Increasing the parameter value results in bandwidth decreasing at a
low frequency.

Change Mode

Offline

Related features

ZGO-03-01-002 Transmission Based CAC

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.22 IP ABIS Pool Band Width Restore (TBWRestore)


Full Name

IP ABIS Pool Band Width Restore

Abbreviation

TBWRestore

3GPP Name

None

3GPP Reference

None
This parameter is a timer for increasing the bandwidth of some channels
whose bandwidth used to be decreased when the bandwidth resource
is enough. This timer should be set when the measured bandwidth is

Description

smaller than the threshold for increasing the bandwidth.

Managed Object

BSC

2-113
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

1..10
Value Range and Step

Step: 1

Unit

Default Value

Default Value
Configuration Reason

Five seconds are appropriate during which the bandwidth is reported


for five times. Such a period will not cause too frequent bandwidth
increasing or bandwidth increasing failure in a long time.
The default value is recommended.

Configuration Rule and


Adjustment Suggestion

1) Decreasing the parameter value results in bandwidth increasing at a


high frequency.
2) Increasing the parameter value results in bandwidth increasing at a
low frequency.

Change Mode

Offline

Related features

ZGO-03-01-002 Transmission Based CAC

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.23 Time of waiting an internal HO command


(TWaitInternalHoCmd)
Full Name

Time of waiting an internal HO command

Abbreviation

TWaitInternalHoCmd

3GPP Name

None

3GPP Reference

None

2-114
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

This parameter specifies the waiting time for an intra-BSC handover


command message from the MSC after the BSC sends an internal
handover request.
Start: The BSC sends an internal handover request to the MSC when
the handover criterion is fulfilled.
Stop: An internal handover command is received from the MSC.
At expiry: Send a RadioUnavail message to the target instance, and
terminate the instance.
Description

Associated timer: None

Managed Object

BSC
1..100

Value Range and Step

Step: 1

Unit

100 ms

Default Value

20

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The default value is set to 20 because two seconds are enough for
signalling transfer at the A interface and signalling processing in the
MSC.
Generally, the default value is recommended. The waiting time can be
appropriately prolonged if the timer expires when waiting for the internal
handover command.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-115
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.5.24 Wait response of bts or btsgroup establish localswitch link


(TWaitLocalSwitch)
Full Name

Wait response of bts or btsgroup establish localswitch link

Abbreviation

TWaitLocalSwitch

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to wait for a local switch setup
acknowledgement from the base station.
Start: A local switch setup request is sent to the base station.
Stop: A local switch setup acknowledgement is received from the base
station.
At expiry: In the case of local switch setup phase, a local switch setup
failure message is responded to the local switch management module.
In the case of local switch stop suspend phase, a local switch suspend
failure message is responded to the local switch management module,

Description

and the instance is released.

Managed Object

BSC
0..80

Value Range and Step

Step: 1

Unit

100 ms

Default Value

20

Default Value

Two seconds are long enough for the Abis interface to transmit signalling

Configuration Reason

and for the BTS to process signalling.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

2-116
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.25 Wait response of localswitch release link


(TWaitLsReleaseAck)
Full Name

Wait response of localswitch release link

Abbreviation

TWaitLsReleaseAck

3GPP Name

None

3GPP Reference

None
This parameter is a protection timer used to wait for a local switch link
connection release acknowledgement message.
Start: A request for releasing the old link connection is sent to the
connection module.
Stop: An acknowledgement of link connection release request is
received from the connection module.
At expiry: In the case of local switch setup phase, a local switch setup
failure message is responded to the local switch management module.
In the case of local switch stop suspend phase, a local switch suspend
failure message is responded to the local switch management module,

Description

and the instance is released.

Managed Object

BSC
0..80

Value Range and Step

Step: 1

Unit

100 ms

Default Value

20

Default Value
Configuration Reason

Two seconds are enough to complete the internal connection release.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None
2-117

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.26 Wait response of localswitch connect (TWaitLSBscConn)


Full Name

Wait response of localswitch connect

Abbreviation

TWaitLSBscConn

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to wait for a local switch connection
acknowledgement message from the connection module.
Start: A local switch connection message is sent to the connection
module.
Stop: A local switch connection acknowledgement message is received
from the connection module. The instance is terminated.
At expiry: A local switch setup failure message is returned to the local

Description

switch management module. And timer TWaitLsReleaseAck is started.

Managed Object

BSC
0..80

Value Range and Step

Step: 1

Unit

100 ms

Default Value

20

Default Value
Configuration Reason

Two seconds are enough to complete the internal connection.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

2-118
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.5.27 Wait request of local switch release link (TWaitLSReleas


eReq)
Full Name

Wait request of local switch release link

Abbreviation

TWaitLSReleaseReq

3GPP Name

None

3GPP Reference

None
This parameter is a protection timer used to wait for a local switch link
release request message.
Start: A local switch set failure acknowledgement message is sent to the
local switch management module.
Stop: A local switch link release request message is received from the
local switch management module.

Description

At expiry: Resume the switch status before the local switch request.

Managed Object

BSC
0..80

Value Range and Step

Step: 1

Unit

100 ms

Default Value

20

Default Value
Configuration Reason

Two seconds are enough for internal interaction between CMP and OMP.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None
2-119

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6 Timer 2
2.6.1 Protective time for RF channel release (RmsT9)
Full Name

Protective time for RF channel release

Abbreviation

RmsT9

3GPP Name

None

3GPP Reference

None
This parameter is timer T9.
Start: An RF CHANNEL RELEASE message is sent to the BTS when
the RANCS instance is released.
Stop: The RANCS instance receives an RF CHANNEL RELEASE ACK
message from the BTS.

Description

At expiry: Release the service instance.

Managed Object

BSC
10..50

Value Range and Step

Step: 1

Unit

100 ms

Default Value

20

Default Value

Generally, the RF CHANNEL RELEASE ACK message can be received

Configuration Reason

from the BTS in two seconds.

2-120
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

The larger the parameter value is, the longer the waiting time is, and the
Configuration Rule and

longer the time needed for service release due to the occurrence of

Adjustment Suggestion

exception. This parameter is invalid now. The RMST11 is set by the


setting of Emlpp.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.2 Queue period of assignment (RmsT11)


Full Name

Queue period of assignment

Abbreviation

RmsT11

3GPP Name

T11

3GPP Reference

3GPP TS 48.008 V5.12.0


This parameter is timer T11, which indicates the longest allowable
queuing time of assignment attempt.
Start: The assignment queuing switch is enabled. No channel is
assigned for an assignment request and the queuing for resources starts.
Stop: An available channel resource is assigned.
At expiry: Release the service instance on the target channel.
This parameter is invalid now. The RMST11 is set by the setting of

Description

Emlpp.

Managed Object

BSC
10..1000

Value Range and Step

Step: 1

Unit

100 ms
2-121

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

60

Default Value

Generally, it is no need to queue if no channel is assigned within six

Configuration Reason

seconds.
The longer the queuing time for assignment is, the more likely the

Configuration Rule and


Adjustment Suggestion

assignment succeeds. However, too long queuing time increases the


access time and impacts user experience. This parameter, locked in the
network management system, cannot be modified. T11 is set by setting
RMST11 in eMLPP.

Change Mode

Offline

Related features

ZGB-03-01-003 Queuing

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.3 Acknowledgment interval for periodic status (RmsT12)


Full Name

Acknowledgment interval for periodic status

Abbreviation

RmsT12

3GPP Name

None

3GPP Reference

None

2-122
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

This parameter is timer T12, which indicates the interval of periodic


status confirmation.
Start: The timer is started for the first time when the RANCS decides to
detect the activity of the opposite end upon receiving a CONNECT CONF
message from the RANA. After that, the timer is periodically started.
Stop: The RANCS instance receives a release message.
At expiry: If the number of timer expiries does not exceed four, the timer
is started. If the number of timer expiries exceeds four, the service
Description

instance is released.

Managed Object

BSC
50..18000

Value Range and Step

Step: 1

Unit

100 ms

Default Value

50

Default Value

Generally, an acknowledgement message can be received from the

Configuration Reason

MSC in five seconds.

Configuration Rule and


Adjustment Suggestion

The larger the parameter value is, the longer the time waiting for an
acknowledgement message is. You can adjust the parameter value
according to the actual situation.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.4 Mode modification process time (RmsT13)


Full Name

Mode modification process time


2-123

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

RmsT13

3GPP Name

None

3GPP Reference

None
This parameter is timer T13, which is used to supervise the mode modify
process of the BTS and MS. Mode modification refers to channel mode
modification. After the assignment of FACCH in the case of no SDCCH,
the channel mode is changed because no new channel will be allocated.
Start: The BSC sends a MODE MODIFY message to the BTS, and
sends a CHANNEL MODE MODIFY message to the MS.
Stop: The BSC receives a MODE MODIFY ACK/NACK message from
the BTS, and receives a CHANNEL MODE MODIFY ACK message
from the MS.
At expiry: Send a BSSMPA ASSIGNMENT FAILURE message to the

Description

MSC.

Managed Object

BSC
35..100

Value Range and Step

Step: 1

Unit

100 ms

Default Value

60

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value, being an experimental value, is recommended.


Increase the parameter value appropriately if the mode modification
failure frequently occurs, that is, the number of times that the timer
expires is large.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

2-124
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Detail

None

2.6.5 Protective time of UM assignment completion (RmsT14)


Full Name

Protective time of UM assignment completion

Abbreviation

RmsT14

3GPP Name

None

3GPP Reference

None
This parameter is timer T14, which indicates the protection time for the
completion of UM assignment.
Start: The target child process sends ASS/HO COM to the source child
process.
Stop: The target child process receives ASS/HO COM ACK from the
source child process.

Description

At expiry: Release the service.

Managed Object

BSC
10..50

Value Range and Step

Step: 1

Unit

100 ms

Default Value

20

Default Value

This parameter is an internal parameter. The default value is

Configuration Reason

recommended.

Configuration Rule and

Increase the parameter value appropriately if the number of UM

Adjustment Suggestion

assignment failures increases.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

2-125
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.6 Waiting time for oriented retry (RmsT16)


Full Name

Waiting time for oriented retry

Abbreviation

RmsT16

3GPP Name

None

3GPP Reference

None
This parameter is timer RmsT16. In a directed retry process, the timer
is used to wait for receiving measurement reports when no target cell
is detected. Upon the expiry of the timer, the directed retry process is
initiated again to find whether some target cell is available. This process
can be repeated for several times.
Start: The source instance initiates a directed retry process after
receiving a radio resource request failure.
Stop: None
At expiry: When the number of timer expiries exceeds three, an
assignment failure message is sent to the MSC to wait for a clear
message. If the number of timer expiries does not exceed three, the

Description

directed retry process is initiated again.

Managed Object

BSC
20..60

Value Range and Step

Step: 1

Unit

100 ms

Default Value

20

Default Value

This parameter is an internal parameter. The default value is

Configuration Reason

recommended.

Configuration Rule and

The longer the waiting time is, the more likely the directed retry

Adjustment Suggestion

succeeds. However, a too long waiting time is meaningless.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

2-126
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.7 Queue period for handover (RmsTqho)


Full Name

Queue period for handover

Abbreviation

RmsTqho

3GPP Name

Tqho

3GPP Reference

TS48.008
This parameter indicates the longest allowable queuing time for a
handover attempt.
Start: When the handover queuing switch is enabled, and no channel is
allocated for the handover request.
Stop: An available channel resource is assigned.
At expiry: Release the service instance on the target channel.
This parameter is already invalid. It is replaced by the handover queuing

Description

timer (Emlpp), which specifies the handover queuing time.

Managed Object

BSC
10..1000

Value Range and Step

Step: 1

Unit

100 ms

Default Value

50

Default Value

Make sure that the handover queuing time is no longer than two

Configuration Reason

handover criteria periods.


This parameter specifies the handover queuing time. The larger the
parameter value is, the longer the handover queuing time is. A longer

Configuration Rule and


Adjustment Suggestion

queuing time can effectively reduce the congestion ratio. However, too
long queuing time may cause handover failure when the signal in the
neighbor cell changes. This parameter is already invalid. It is replaced
by the handover queuing timer (Emlpp), which specifies the handover
queuing time.

2-127
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.8 First overload period of flow traffic control (mT11)


Full Name

First overload period of flow traffic control

Abbreviation

mT11

3GPP Name

None

3GPP Reference

None
The parameter is timer mT11, which is used for flow control in the case
of cell overload. mT11 works together with mT12 to modify the ACCESS
CONTROL parameter configured for the cell and inform the MS about
this modification through system information to achieve the flow control.
The RACH LOAD INDICATION message from the BTS is not processed
when the timer is started. The value set for timer mT11 must be smaller
than that for timer mT12.
Start: An RACH LOAD INDICATION message is received from the BTS.
Stop: None
At expiry: Continue processing the RACH LOAD INDICATION message
of the BTS.

Description

Associated timer: mT12

Managed Object

BSC
30..150

Value Range and Step

Step: 1

Unit

100 ms
2-128

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Default Value
Default Value
Configuration Reason

80
The fluctuation of overload indication is unlikely to cause the flow
control fluctuation if new overload indication is not processed within
eight seconds.
The larger the parameter value is, the more stable the flow control is due

Configuration Rule and

to lower sensitivity to load indication. The smaller the parameter value

Adjustment Suggestion

is, the more likely the flow control fluctuates due to higher sensitivity to
load indication.

Change Mode

Offline

Related features

ZGB-03-04-001 BSC Load Control

Related Parameters

[BSC]mT12

Relationship

mT11<mT12

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.9 Second overload period of flow traffic control (mT12)


Full Name

Second overload period of flow traffic control

Abbreviation

mT12

3GPP Name

None

3GPP Reference

None

2-129
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The parameter is timer mT12, which is used for flow control in the case
of cell overload. mT12 works together with mT11 to modify the ACCESS
CONTROL parameter configured for the cell and inform the MS about
this modification through system information to achieve the flow control.
The value of this timer must be larger than that of mT11 timer. The
process how mT11 and mT12 control the cell traffic is as follows: When
an overload message is received at the network side, the system
lowers the traffic level by one, and then starts mT11 and mT12. The
OVERLOAD message received before the expiry of mT11 is neglected.
If an OVERLOAD message is received after the expiry of mT11 but
before the expiry of mT12, the system lowers the traffic level by one
again, and restarts mT11 and mT12. If no OVERLOAD message is
received after the expiry of mT12, the system increases the traffic level
by one and then restarts mT12. The change of traffic level means
different traffic rejection ratio.
Start: An RACH LOAD INDICATION message is received from the BTS.
Stop: A RACH LOAD INDICATION message from the BTS is received
after the expiry of mT11.
At expiry: Lower the traffic level by one.
Description

Associated timer: mT11

Managed Object

BSC
50..200

Value Range and Step

Step: 1

Unit

100 ms

Default Value

150
mT11 is used to prevent the fluctuation of load indication. mT12 is used

Default Value
Configuration Reason

to adjust traffic level after a new load indication is received. If no load


indication is received after the expiry of mT12, the system lowers the
flow control level. 150The default value is set to 150, which is almost
twice the value of

Configuration Rule and

The larger the parameter value is, the greater the flow control fluctuation

Adjustment Suggestion

is. Similarly, a smaller parameter value corresponds to less fluctuation.

Change Mode

Offline

Related features

ZGB-03-04-001 BSC Load Control

Related Parameters

[BSC]mT11

Relationship

mT11<mT12

Related Interfaces

None

Impact on Equipment

Impact on service

2-130
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config
Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.10 Time of micro-micro handover delay (Tmicro)


Full Name

Time of micro-micro handover delay

Abbreviation

Tmicro

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to prevent an MS travelling fast from
camping on the same layer. The timer is started when the MS is handed
over to a cell (or a call is set up). Before the expiry of the timer, the
MS cannot be handed over to a neighbour cell on the same layer. A
neighbour cell on the same layer can be a candidate only after the
expiry of the timer.
Start: A call is set up.
Stop: None
At expiry: Enable the handover on the same layer.

Description

Associated timer: None

Managed Object

BSC
1..200

Value Range and Step

Step: 1

Unit

100 ms

Default Value

80
The purpose of this timer is to reduce the handover times of the

Default Value
Configuration Reason

fast-travelling MS in a lower-layer network. Generally, it is sure that the


MS still camping on the cell after eight seconds is not travelling fast. To
prevent the handover of the MS on the same layer, the default value
is set to 80.

Configuration Rule and


Adjustment Suggestion
Change Mode

Set the parameter value according to the geographic location and


distribution of cells and the mobility of MSs in the area. The larger the
parameter value is, the longer the limitation on handover is.
Offline

2-131
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.11 BSIC decoding period (Tbsic)


Full Name

BSIC decoding period

Abbreviation

Tbsic

3GPP Name

None

3GPP Reference

None
This parameter specifies a time period starting from the setup of a call or
the completion of a handover (inter-cell or intra-cell) during which the
evaluation of C/I is deemed as unreliable and therefore the handover
to a specific TRX is not allowed. In this period, the MS can decode the
BSIC of the interfering (adjacent) cell before a handover decision.
This parameter is only valid in the case of concentric cell.
Start: Relevant parameters are initiated after the setup of a link to the
MS upon immediate assignment, assignment, or handover.
Stop: The timer expires.

Description

At expiry: Reset the timer.

Managed Object

BSC
20..640

Value Range and Step

Step: 1

Unit

100 ms

Default Value

50

Default Value

Generally, C/I value obtained within five seconds after the setup of a call

Configuration Reason

is regarded as unreliable.
2-132

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Configuration Rule and

The default value is recommended. The larger the parameter value is,

Adjustment Suggestion

the longer the time used for BSIC decoding is.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.12 Handover protecting timer to WCDMA/FDD (RmsT3121)


Full Name

Handover protecting timer to WCDMA/FDD

Abbreviation

RmsT3121

3GPP Name

T3121

3GPP Reference

3GPP TS 44.018
This parameter is timer T3121, which specifies the protection time after
the inter-system to utran handover command (UM) is sent to the MS.
Start: When the BSC sends an INTER-SYSTEM TO UTRAN
HANDOVER COMMAND message to the MS.
Stop: When the BSC receives a CLEAR COMMAND from the MSC
(which is generally sent after the completion of handover), or receives a
HANDOVER FAILURE message from the MS.
At expiry: The BSC sends a CLEAR REQUEST message to the MSC.
The cause value is CAUSE_RI_MSG_FAIL, indicating a message failure

Description

at the radio interface.

Managed Object

BSC
1..650

Value Range and Step

Step: 1

Unit

100 ms
2-133

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

100

Default Value

The default value is set in consideration of the time needed for the MS to

Configuration Reason

receive an inter-system handover command and complete the handover.

Configuration Rule and


Adjustment Suggestion

A too large parameter value may result in the waste of channel resources
and traffic congestion. A too small parameter value may decrease the
handover success rate.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.13 Immediate assignment period (RmsT3101)


Full Name

Immediate assignment period

Abbreviation

RmsT3101

3GPP Name

T3101

3GPP Reference

3GPP TS 44.018
This parameter is timer T3101, which is used to supervise the immediate
assignment process.
Start: When the BSC sends an IMMEDIATE ASSIGNMENT COMMAND
message.
Stop: When an ESTABLISH INDICATION message is received from
the BSC.
At expiry: The BSC sends an RF CHANNEL RELEASE message to

Description

the BTS.

Managed Object

BSC

2-134
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

10..100
Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The default value is set in consideration of the time needed for sending
an immediate assignment message to the MS and the time needed
for the MS to access the network.
A too large parameter value may result in the waste of channel resources
and traffic congestion. A too small parameter value may decrease the
immediate assignment success rate.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.14 Handover period of source cell (RmsT3103)


Full Name

Handover period of source cell

Abbreviation

RmsT3103

3GPP Name

T3103

3GPP Reference

3GPP TS 44.018

2-135
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is timer T3103, which is used to supervise an intra-BSC


handover process.
Start: When the BSC sends an HANDOVER COMMAND message to
the MS.
Stop: When the BSC receives a HANDOVER COMPLETE message on
the new channel from the MS, or a HANDOVER FAILURE message
on the old channel from the MS.
At expiry: The BSC sends a CLEAR REQUEST message to the MSC.
The cause value is CAUSE_RI_FAIL, indicating a radio interface failure.
Description

The new channel is released.

Managed Object

BSC
0..1000

Value Range and Step

Step: 1

Unit

100 ms

Default Value

60

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The default value is set in consideration of the time needed for sending
the handover command to the MS and the time needed for the MS to
complete the inter-cell handover.
A too large parameter value may result in the waste of channel resources
and traffic congestion. A too small parameter value may decrease the
handover success rate.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]rmst1

Relationship

RmsT3103 < RmsT1

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-136
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.6.15 Assignment period (RmsT3107)


Full Name

Assignment period

Abbreviation

RmsT3107

3GPP Name

T3107

3GPP Reference

3GPP TS 44.018
This parameter is timer T3107, which is used to supervise an assignment
process and an intra-cell handover process.
Start: When the BSC sends an RIL3_RR ASSIGNMENT COMMAND
message to the MS.
Stop: When the BSC receives an RIL3_RR ASSIGNMENT COMPLETE
or RIL3_RR ASSIGNMENT FAILURE message.
At expiry: In the case of an assignment process, both the new and old
channels are released, relevant connections to the MS are cleared, and
a BSSAP ASSIGNMENT FAILURE message is sent to the MSC. In the
case of an intra-cell handover process, a CLEAR REQUEST message
is sent to the MSC. The cause value is CAUSE_RI_FAIL, indicating a

Description

radio interface failure.

Managed Object

BSC
0..1000

Value Range and Step

Step: 1

Unit

100 ms

Default Value

60

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The default value is set in consideration of the time needed for sending
the assignment command to the MS and the time needed for the MS to
complete the assignment.
A too large parameter value may result in the waste of channel resources
and traffic congestion. A too small parameter value may decrease the
assignment success rate.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]rmst1

Relationship

RmsT3107 < RmsT1

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-137
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.16 TCH Channel release period (RmsT3109)


Full Name

TCH Channel release period

Abbreviation

RmsT3109

3GPP Name

T3109

3GPP Reference

3GPP TS 44.018
This parameter is timer T3109, which is used to supervise a channel
release process.
Start: When the BSC send an RIL3_RR CHANNEL RELEASE message
to the MS.
Stop: When the BSC receives a RELEASE INDICATION message
from the BTS, which is sent by the BTS when a DISC frame from the
MS is received.
At expiry: The BSC sends an RF CHANNEL RELEASE message to the

Description

BTS. The cause value is T3109OUT.

Managed Object

BSC
0..1000

Value Range and Step

Step: 1

Unit

100 ms

Default Value

50
The default value is set in consideration of the time needed for the

Default Value

MS to complete the channel release after receiving a channel release

Configuration Reason

command, and the time needed for the call drop of the MS caused by
the failure of receiving a channel release command.
To avoid crosstalk caused by network-side channel release before the

Configuration Rule and


Adjustment Suggestion

completion of channel release at the MS side, the value of T3109 must


be larger than that of the radio link expiration timer at the MS side.
However, a too large parameter value may result in the waste of channel
resources and traffic congestion.

Change Mode

Offline

Related features

None

2-138
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.17 TCH Channel deactivation delay (RmsT3111)


Full Name

TCH Channel deactivation delay

Abbreviation

RmsT3111

3GPP Name

T3111

3GPP Reference

3GPP TS 44.018
This parameter is timer RmsTT3111, which specifies a protection time to
ensure that the radio link layer is disconnected after the radio link layer
at the Um interface is released. The release and deactivation of the
radio channel is performed upon the expiry of this timer.
Start: When the BSC receives a RELEASE INDICATION message.
At expiry: The BSC sends an RF CHANNEL RELEASE message to the

Description

BTS. The cause value is T3111OUT.

Managed Object

BSC
1..300

Value Range and Step

Step: 1

Unit

100 ms

Default Value

Default Value

The default value is set in consideration of the time needed for the BTS

Configuration Reason

to send the UA message.


A too large parameter value may result in the waste of channel resources

Configuration Rule and

and traffic congestion. If the parameter value is too small, the BTS

Adjustment Suggestion

cannot send the UA message to the MS in time, and thus the MS may
fail to complete the channel release in a short time.
2-139

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.18 Continue timer for mode modify (TModeModifyConn)


Full Name

Continue timer for mode modify

Abbreviation

TModeModifyConn

3GPP Name

None

3GPP Reference

None
This parameter is a connection delay timer used in the mode change
process. This timer is used to wait for the complete of connection (Abis
connection and TC connection) after a connection request is sent.
Start: A connection request is sent.
Stop: All connections are completed.

Description

At expiry: Clear this service instance.

Managed Object

BSC
50..70

Value Range and Step

Step: 1

Unit

100 ms

Default Value

50

Default Value

The default value is set to 50 because five seconds are enough to

Configuration Reason

complete all connections.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.


2-140

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.19 Handover protecting time to UTRAN (mT7)


Full Name

Handover protecting time to UTRAN

Abbreviation

mT7

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to wait for a response from the MSC
after a HANDOVER REQUIRED message is sent to the MSC and the
target cell is a UTRAN cell.
Start: The BSC sends a HANDOVER REQUIRED message to the MSC,
and the target cell is a UTRAN cell.
Stop: The BSC receives a HANDOVER COMMAND message from
the MSC.
At expiry: Set a penalty time for the target UTRAN cell specified by the
HANDOVER REQUIRED message, during which the handover priority
of the target cell is decreased.

Description

This timer is not in practical use.

Managed Object

BSC
1..65535

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100
2-141

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The default value is set to 100 because 10 seconds are generally


enough for the transmission of signallings between the MSC and the
UTRAN and the preparation of handover resources in the UTRAN.
Increase the parameter value appropriately if the timer frequently expires
when waiting for the handover command. Or else, the default value is
recommended.

Change Mode

Offline

Related features

ZGO-02-03-009 GSM/WCDMA Interworking Phase II

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.20 Time to wait A handover request (TWaitAHoReq)


Full Name

Time to wait A handover request

Abbreviation

TWaitAHoReq

3GPP Name

None

3GPP Reference

None
This parameter specifies the waiting time for the handover through A
interface in a 2G/3G relocation process.
Start: A radio resource reservation success message is sent to the RNC.
Stop: A handover request is received from the MSC.
At expiry: Release the radio resource, and terminate the instance.

Description

Associated timer: None

Managed Object

BSC
4..50

Value Range and Step

Step: 1

2-142
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Unit

100 ms

Default Value

10

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The default value is set to 10 because one second is enough for the
RNC to send a handover request to the MSC and for the MSC to forward
the handover request to the BSC.
Generally, the default value is recommended. The waiting time can
be appropriately prolonged if the timer expires when waiting for the
handover through A interface.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.21 Time of destination instance waiting for available resources


when forced disconnection (RmsT15(TForceOccupy))
Time of destination instance waiting for available resources when forced
Full Name

disconnection

Abbreviation

RmsT15(TForceOccupy)

3GPP Name

None

3GPP Reference

None

2-143
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the waiting time for the release of resource
when an instance is forcibly released.
Start: A PREEMPT APPLY message is sent to the object to be released
when the target instance is going to be forcibly released.
Stop: The target instance receives a response of RESOURCE
AVAILABLE from the object to be released.
At expiry: Search for another instance that can be forcibly released. If
the instance to be released exists, a forced release process is retried,
Description

and RmsT15 (TForceOccupy) is started.

Managed Object

BSC
10..50

Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value

The default value is set to 30 because three seconds are enough for the

Configuration Reason

forcibly-released instance to release the resource.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.22 Protecting time of FUC response to system message


broadcast (BcProtect)
Full Name

Protecting time of FUC response to system message broadcast


2-144

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Abbreviation

BcProtect

3GPP Name

None

3GPP Reference

None
This parameter is a protection timer used to wait for a response from
the FUC after the system information is broadcasted. A response from
the FUC indicates that the BTS has correctly received the system
information.
Start: The BSC sends the system information to the BTS.
Stop: The BSC receives a response to the system information from
the BTS.
At expiry: If the number of timer expiries does not exceed four (the
maximum number of allowable times), the BSC sends the system
information to the BTS again and the timer is restarted. If the number
of timer expiries exceeds four, the BSC stops sending the system
information to the BTS and clears the cell instance information of the
BTS.

Description

This timer is not in practical use.

Managed Object

BSC
30..100

Value Range and Step

Step: 1

Unit

100 ms

Default Value

50

Default Value

Five seconds are enough for the FUC to receive and process the system

Configuration Reason

information.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

2-145
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.23 HO performed ack timer (TwaitHoPFMAck)


Full Name

HO performed ack timer

Abbreviation

TwaitHoPFMAck

3GPP Name

None

3GPP Reference

None
When IP bearer is adopted on the user plane at the A interface, the BSC
needs to notify the CN to change its vocoder in an intra-BSC handover
process because TC is located in the MGW. The vocoder change in
the CN is triggered by a HANDOVER PERFORMED message. A
HANDOVER PERFORMED ACK message is required to ensure that
the MSC has successfully received the HANDOVER PERFORMED
message and required the MGW to change the vocoder and thus
avoid voice problems. This parameter is a timer used to wait for the
HANDOVER PERFORMED ACK message from the MSC.
Start: When the BSC sends a HANDOVER PERFORMED message
to the MSC.
Stop: The BSC receives a HANDOVER PERFORMED ACK message
from the MSC.
At expiry: Send a CLEAR REQUEST message to the MSC to release
the call. The cause value is 0x60, indicating a protocol error between the

Description

BSC and the MSC.

Managed Object

BSC
50..70

Value Range and Step

Step: 1

Unit

100 ms

Default Value

60

Default Value

Six seconds are enough for signalling transfer and the processing in

Configuration Reason

the MSC.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-05-02-001 Remote Transcoder Support

2-146
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.24 Timer of TRAU frame Synchronization (TuTrauSyn)


Full Name

Timer of TRAU frame Synchronization

Abbreviation

TuTrauSyn

3GPP Name

timer of TRAU frame synchronization

3GPP Reference

3GPP TS 48.060, 3GPP TS 48.061


This parameter is a timer indicating the loss of TRAU frame
synchronization. If the function of call release upon the loss of TRAU
frame synchronization is supported, the call will be released upon the
expiry of the timer.
Start: The MS is allocated a TCH.
Stop: The DSP detects that TRAU frame (voice frame) has been
synchronized.
At expiry: Release the call.

Description

Associated timer: None

Managed Object

BSC
10..600

Value Range and Step

Step: 1

Unit

100 ms

Default Value

10

Default Value
Configuration Reason

Generally, one second (corresponding to the default value 10) is enough


for the MS to detect the media data of the TRAU frame after a TCH
is allocated to it.

2-147
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Generally, the default value is recommended. Increase the value of


Configuration Rule and
Adjustment Suggestion

this parameter appropriately and observe whether the rate of call drops
caused by the detection of TRAU frames is reduced. If yes, set a larger
value to the parameter until the call drop rate caused by TRAU frames
does not change greatly.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.25 Round trip delay (RtdDefault)


Full Name

Round trip delay

Abbreviation

RtdDefault

3GPP Name

Round Trip Delay

3GPP Reference

48.058
This parameter specifies the Round Trip Delay (RTD). In a handover
process when AMR voice encoding is adopted, the BSC sends a
PRE-HANDOVER NOTIFICATION message to the BTS. During the
RTD, the BTS negotiates with the TC to take some actions, such as
disable the voice rate adjustment and terminate TFO. After that, the BSC
sends a handover command to the MS. RTD is the transmission delay
caused by the round trip between the BTS and the TC. It is reported
by the BTS to the BSC through a ROUND TRIP DELAY REPORT
message. The BSC uses the default value of RTD (RtdDefault) before
receiving this message.
Start: The BSC sends a PRE-HANDOVER NOTIFICATION message

Description

to the BTS.
2-148

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Stop: The BSC receives a PRE-HANDOVER NOTIFICATION ACK


message (a user-defined message at the Abis interface) from the BTS.
At expiry: The BSC sends a handover command to the MS.
Managed Object

BSC
1..20

Value Range and Step

Step: 1

Unit

20 ms

Default Value

Default Value

100 ms is enough in consideration of the time needed for message

Configuration Reason

transfer on the user plane between the BTS and the TC.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended. If the delay caused by


message transfer on the user plane between the BTS and the TC is
long, increase the parameter value appropriately.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.26 Timer to wait a relocation commit MSG from RNC


(TWaitRncRelocComm)
Full Name

Timer to wait a relocation commit MSG from RNC

Abbreviation

TWaitRncRelocComm

3GPP Name

None

3GPP Reference

None

2-149
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter specifies the time for the BSC to wait for a RELOACTION
COMMIT message from the RNC when the Iur-g interface configured
between 2G and 3G is used for relocation.
Start: A HandoverRequestAck message is sent to the MSC.
Stop: A RELOCATION COMMIT message is received from the RNC
at the Iur-g interface.
At expiry: Release the corresponding relocation instance and allocated
Description

resources.

Managed Object

BSC
0..200

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value
Configuration Reason

The default value is set in consideration of the maximum delay of the


HandoverRequestAck message from the BSC to the MSC, and then
to the RNC.

Configuration Rule and

The default value, already taking the message delay on site into

Adjustment Suggestion

consideration, is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.27 Subcell PingPong handover timer (TSCPingPang)


Full Name

Subcell PingPong handover timer

Abbreviation

TSCPingPang
2-150

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

3GPP Name

None

3GPP Reference

None
This parameter indicates a time period after a subcell handover, in which
the MS is handed over between subcells frequently, for example, the MS is
handed over back and forth between two subcells within the same BSC, or
the MS is handed over back and forth between two subcells between two
BSCs. The fast inter-subcell handovers are counted in the performance

Description

report.

Managed Object

BSC
20..1000

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value
Configuration Reason

The default value is set based on a common radio environment.


Generally, it is deemed that a ping-pong handover occurs if handover
occurs frequently between two subcells in 10 seconds.
The smaller the parameter value is, the less restrictive the criterion for

Configuration Rule and


Adjustment Suggestion

ping-pong handover is. Similarly, the larger the parameter is, the more
restrictive the criterion for ping-pong handover is. This parameter can
be used to evaluate whether inter-subcell handover parameters are
properly set.

Change Mode

Offline

Related features

ZGO-04-02-005 Co-BCCH

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-151
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.6.28 Confirm BIPB fault time (TConfBIPBFault)


Full Name

Confirm BIPB fault time

Abbreviation

TConfBIPBFault

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to confirm that a BIPB failure occurs. The
timer is started when a BIPB failure occurs. Upon the expiry of the timer,

Description

all DSPs of the BIPB board are switched to the standby ones.

Managed Object

BSC
30..1200

Value Range and Step

Step: 1

Unit

100 ms

Default Value

950

Default Value

Generally, the restart of the BIPB board can be completed within 95

Configuration Reason

seconds, which avoids the active/standby switchover.


The smaller the parameter value is, the shorter the service interruption

Configuration Rule and

time is. If all sites in the system are IP-based sites, decrease the

Adjustment Suggestion

parameter value appropriately to reduce the service interruption time. If


all sites are E1-based sites, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]TConfBIPBDSPFault

Relationship

TConfBIPBDSPFault < TConfBIPBFault

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-152
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.6.29 Confirm BIPB DSP fault time (TConfBIPBDSPFault)


Full Name

Confirm BIPB DSP fault time

Abbreviation

TConfBIPBDSPFault

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to confirm that a BIPB DSP failure occurs.
The timer is started when a BIPB DSP failure occurs. Upon the expiry of

Description

the timer, the BIPB board switches the failed DSP to the standby one.

Managed Object

BSC
5..600

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value

Generally, the BIPB DSP can be reset in 10 seconds, which avoids the

Configuration Reason

active/standby switchover.

Configuration Rule and

You can adjust the parameter value according to the actual situation after

Adjustment Suggestion

measuring the time needed for DSP restoration after the DSP is reset.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]TConfBIPBFault

Relationship

TConfBIPBDSPFault < TConfBIPBFault

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.30 Confirm LAPD fault time (TConfLapdFault)


Full Name

Confirm LAPD fault time


2-153

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

TConfLapdFault

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to confirm that an LAPD failure occurs.
The timer is started when a LAPD failure occurs. Upon the expiry of the

Description

timer, all CPUs of the LAPD board are switched to the standby ones.

Managed Object

BSC
30..1200

Value Range and Step

Step: 1

Unit

100 ms

Default Value

950

Default Value

Generally, the restart of the LAPD board can be completed within 95

Configuration Reason

seconds, which avoids the active/standby switchover.

Configuration Rule and


Adjustment Suggestion

The minimum value can be used according to the actual situation


because 1+1 backup is adopted for the LAPD board to support the
immediate active/standby switchover.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]TConfLapdCpuFault

Relationship

TConfLapdCpuFault < TConfLapdFault

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.31 Confirm LAPD CPU fault time (TConfLapdCpuFault)


Full Name

Confirm LAPD CPU fault time

Abbreviation

TConfLapdCpuFault

2-154
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to confirm that an LAPD CPU failure occurs. The timer is started when a LAPD CPU failure occurs. Upon the expiry of the timer, the LAPD board switches the failed CPU to the standby
one. In the case of CPU1 failure, all CPUs of the LAPD board need to be
switched to the standby ones. In the case of non-CPU1 failure, only the

Description

failed CPU needs to be switched to the standby one.

Managed Object

BSC
5..600

Value Range and Step

Step: 1

Unit

100 ms

Default Value

50

Default Value

A delay of five seconds is used to make sure that the LAPD CPU failure

Configuration Reason

is not transient.

Configuration Rule and


Adjustment Suggestion

The minimum value can be used according to the actual situation


because 1+1 backup is adopted for the LAPD board to support the
immediate active/standby switchover.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]TConfLapdFault

Relationship

TConfLapdCpuFault < TConfLapdFault

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.32 Confirm Sunit normal time (TConfSunitNor)


Full Name

Confirm Sunit normal time

2-155
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

TConfSunitNor

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to determine whether IPRB DSP, BIPB
DSP, or LAPD CPU restores from a failure. The timer is started when
IPRB DSP, BIPB DSP, or LAPD CPU restores. Upon the expiry of the
timer, the system searches for failed board(s). If a failed board is found,

Description

the system switches the board to the standby one.

Managed Object

BSC
5..300

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value
Configuration Reason

10 seconds are enough to confirm that the unit restores from a failure.

Configuration Rule and

A value close to the default value can be used. A great modification is

Adjustment Suggestion

not recommended.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]TconfBIPBFault
[BSC]TconfLapdFault

Relationship

The parameter must be smaller than TconfBIPBFault and


TconfLapdFault.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.6.33 Paging Interval (PagWaitTime)


Full Name

Paging Interval
2-156

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Abbreviation

PagWaitTime

3GPP Name

None

3GPP Reference

None
This parameter determines the time of the BSC in waiting for a paging
response after sending a paging message. The paging mode includes
exact paging and common paging. If the BSC does not receive any response within this time range, the BSC will initiate the paging operation

Description

again according to the parameter configuration.

Managed Object

Cell

Value Range and Step

20..80

Unit

100ms

Default Value

25

Default Value
Configuration Reason

A paging response from the MS can be received within 2.5s.

Configuration Rule and

It is required to configure this parameter by considering the configuration

Adjustment Suggestion

of paging module and the transmission delay of Abit interface.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.6.34 Time of Cobcch Wait for MR Report (TCobcchWaitMR)


Full Name

Time of Cobcch Wait for MR Report

Abbreviation

TCobcchWaitMR

3GPP Name

Null
2-157

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

Null
The parameter indicates the duration of waiting for MR report when

Description

Cobcch assignment is performed.

Managed Object

BSC
[0..30]

Value Range and Step

step: 1

Unit

100ms

Default Value

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Timer2

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

2.6.35 SDCCH Channel release period (TSDRelPeriod)


Full Name

SDCCH Channel release period

Abbreviation

TSDRelPeriod

3GPP Name

None

3GPP Reference

None

Description

This parameter specifies the release period of the SDCCH.

Managed Object

BSC

2-158
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

0..1000
Value Range and Step

Step: 1

Unit

100ms

Default Value

50

Default Value

The SDCCH release period is consistent with the default value of the

Configuration Reason

TCH.

Configuration Rule and

The time for the abnormal release of the SDDCH can be reduced as

Adjustment Suggestion

required by test.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork->BSC Managed Element->Config SetBSC


Function->Timer2

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

2.6.36 SDCCH Channel deactivation delay (TSDDeactDelay)


Full Name

SDCCH Channel deactivation delay

Abbreviation

TSDDeactDelay

3GPP Name

None

3GPP Reference

None

Description

This parameter specifies the deactivation delay of SDCCH .

Managed Object

BSC
1..300

Value Range and Step

Step: 1

Unit

100ms

2-159
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value

The SDCCH release period is consistent with the default value of the

Configuration Reason

TCH.

Configuration Rule and

The parameter is a release protection delay, and a value less than

Adjustment Suggestion

1 second is enough.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork->BSC Managed Element->Config SetBSC


Function->Timer2

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

2.7 GPRS Maximum Retrying Times


2.7.1 Max times of BVC block retry (BVCBlkMax)
Full Name

Max times of BVC block retry

Abbreviation

BVCBlkMax

3GPP Name

BVC-BLOCK-RETRIES

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"

2-160
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

When blocking a PTP BVC is required due to OAM intervene or device


failure, the BSS sets the status of the BVC to "Blocked" and then
discards uplink service data. It is not allowed to block or unblock a
signalling BVC.
To notify SGSN to stop sending downlink data, BSS initiates BVC
blocking process. After sending a "BVC BLOCK" message to the SGSN,
the BSS restarts the "BVC BLOCK" process if it fails to receive a "BVC
BLOCK ACK" message from the SGSN within BSSGP T1.
If no response is received from the SGSN after the BSS sends the "BVC
BLOCK" message for N times, the BSC stops sending the "BVC BLOCK"
message and informs the OMS about the failure. This parameter value,
Description

N, indicates the maximum number of BVC BLOCK attempts.

Managed Object

BSC
3..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is recommended by the protocol.


Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS maximum Retrying Times

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-161
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.7.2 Max times of BVC unblock retry (BVCUblkMax)


Full Name

Max times of BVC unblock retry

Abbreviation

BVCUblkMax

3GPP Name

BVC-UNBLOCK-RETRIES

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


When unblocking a PTP BVC is required due to OAM intervene or the
removal of a device failure, the BSS sets the status of the BVC to
"Unblocked". It is not allowed to block or unblock a signalling BVC.
To notify the SGSN to stop sending downlink data, the BSS initiates
a BVC blocking process. After sending a "BVC UNBLOCK" message
to the SGSN, the BSS restarts the "BVC UNBLOCK" process if it fails
to receive a "BVC UNBLOCK ACK" message from the SGSN within
BSSGP T1.
If no response is received from the SGSN after the BSS sends the "BVC
UNBLOCK" message for N times, the BSC stops sending the "BVC
UNBLOCK" message and informs the OMS about the failure. This
parameter value, N, indicates the maximum number of BVC UNBLOCK

Description

attempts.

Managed Object

BSC
3..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is recommended by the protocol.


Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-162
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS maximum Retrying Times

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.7.3 MAX times of BVC reset retry (BVCRestMax)


Full Name

MAX times of BVC reset retry

Abbreviation

BVCRestMax

3GPP Name

BVC-RESET-RETRIES

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


To ensure the BVC status at both sides (BSS and SGSN) is the same, a
"BVC RESET" process must be initiated in one of the following cases:
1) a system failure affecting BVC function in the BSS or SGSN, for
example, a restart upon power-on; 2) a network service entity failure on
the lower layer, for example, a frame relay failure; 3) a capability update
of a network service entity on the lower layer, for example, a change of
frame relay capability from 0kbps to greater than 0kbps; 4) a change of
relation between BVC and a cell.
A "Signalling BVC RESET" process shall be initiated in the occurrence of
a failure impacting NSE. A "PTP BVC RESET" process shall be initiated
in the occurrence of a failure impacting only one BVC. After a "Signalling
BVC RESET" process is successfully completed, a "PTP BVC RESET"
process must be initiated for all BVCs of the NSE.
After sending a "BVC RESET" message to the SGSN, the BSS restarts
the "BVC RESET" process if it fails to receive a "BVC RESET ACK"
message from the SGSN within BSSGP T2.
If no response is received from the SGSN after the BSS sends the "BVC
RESET" message for N times, the BSC stops sending the "BVC RESET"
message and informs the OMS about the failure. This parameter value,
N, indicates the maximum number of BVC RESET attempts.

Description

This parameter is changed in V6.20.614a.

Managed Object

BSC
0..255

Value Range and Step

Step: 1

Unit

None

Default Value

2-163
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is recommended by the protocol.


Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS maximum Retrying Times

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.7.4 Max times of NS block retry (NSBlkMax)


Full Name

Max times of NS block retry

Abbreviation

NSBlkMax

3GPP Name

NS-BLOCK-RETRIES

3GPP Reference

TS48.016: "Network Service"


After the BSC sends an "NS BLOCK" message to the SGSN, the "NS
BLOCK" process is initiated again if the BSC does not receive an "NS
BLOCK ACKNOWLEDGE" message from the SGSN within the time
specified by NS_T1.
If no response is received from the SGSN after the BSC sends the "NS
BLOCK" message for N times, the BSC terminates the "NS BLOCK"
process and informs the OMS about the failure. This parameter value,

Description

N, indicates the maximum number of NS BLOCK attempts.

Managed Object

BSC
0..10

Value Range and Step

Step: 1
2-164

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is recommended by the protocol.


Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS maximum Retrying Times

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.7.5 Max times of NS unblock retry (NSUnblkMax)


Full Name

Max times of NS unblock retry

Abbreviation

NSUnblkMax

3GPP Name

NS-UNBLOCK-RETRIES

3GPP Reference

TS48.016: "Network Service"


After the BSC sends an "NS UNBLOCK" message to the SGSN, the "NS
UNBLOCK" process is initiated again if the BSC does not receive an
"NS UNBLOCK ACKNOWLEDGE" message from the SGSN within the
time specified by NS_T1.
If no response is received from the SGSN after the BSC sends the "NS
BLOCK" message for N times, the BSC terminates the "NS BLOCK"
process and informs the OMS about the failure. This parameter value,

Description

N, indicates the maximum number of NS BLOCK attempts.

2-165
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

BSC
0..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is recommended by the protocol.


Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS maximum Retrying Times

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.7.6 Max times of NS alive retry (NSAliveMax)


Full Name

Max times of NS alive retry

Abbreviation

NSAliveMax

3GPP Name

NS-ALIVE-RETRIES

3GPP Reference

TS48.016: "Network Service"

2-166
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

After the BSC sends an "NS Alive" message to the SGSN, the "NS
Alive" process is initiated again if the BSC does not receive an "NS
Alive ACKNOWLEDGE" message from the SGSN before the timeout
of NS_T4. The "NS Alive" process, being specified by the protocol, is
intended to test the connection between two ends of NSVC.
If no response is received from the SGSN after the BSC sends the
"NS Alive" message for N times, the BSC terminates the "NS Alive"
process and informs the OMS about the failure. This parameter value,
Description

N, indicates the maximum number of NS Alive attempts.

Managed Object

BSC
0..20

Value Range and Step

Step: 1

Unit

None

Default Value

10

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is recommended by the protocol.


Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS maximum Retrying Times

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.7.7 Max times of suspend retry (SuspendMax)


Full Name

Max times of suspend retry


2-167

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

SuspendMax

3GPP Name

SUSPEND-RETRIES

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


When originating a voice service, the MS supporting Class B GPRS
sends a "SUSPEND" message to the BSS over SDCCH. Upon receiving
the "SUSPEND" message, the BSS initiates a "SUSPEND" process to
notify the SGSN to stop sending "PS Paging" and "Downlink Packet
Data".
After sending a "SUSPEND" message to the SGSN, the BSS restarts the
"SUSPEND" process if it fails to receive a "SUSPEND ACK" message
from the SGSN within BSSGP T3.
If no response is received from the SGSN after the BSS sends the
"SUSPEND" message for N times, the BSC terminates the "SUSPEND"
process and informs the OMS about the failure. This parameter value,

Description

N, indicates the maximum number of SUSPEND attempts.

Managed Object

BSC
0..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is recommended by the protocol.


Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]ResumeSetOpt

Relationship

This parameter is only valid when the switch of SUSPEND/RESUME


process is enabled.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS maximum Retrying Times

2-168
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.7.8 Max times of resume retry (ResumeMax)


Full Name

Max times of resume retry

Abbreviation

ResumeMax

3GPP Name

RESUME-RETRIES

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


This parameter is a BSSGP-layer parameter. When a GPRS-attached
MS leaves the dedicated mode, the BSS can adopt one of the following
policies:
Notify the MS to update the routing area.
Notify the SGSN to resume the GPRS service support.
When the "Routing Area Update" policy is adopted, the MS negotiates
with the SGSN directly about "GMM Status". If the "RESUME" policy is
adopted, which is generally used for MS in packet transmission state,
the BSS initiates a "RESUME" process to notify the SGSN to start the
transport of downlink packets. After sending a "RESUME" message to
the SGSN, the "RESUME" process is initiated again if no "RESUME
ACK" or "RESUME NACK" message is received from the SGSN within
BSSGP T4.
If no response is received from the SGSN after the BSS sends the
"RESUME" message for N times, the BSC terminates the "RESUME"
process and informs the OMS about the failure. This parameter value,

Description

N, indicates the maximum number of RESUME attempts.

Managed Object

BSC
0..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion
Change Mode

The default value is recommended by the protocol.


Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.
Offline

2-169
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

None

Related Parameters

[BSC]ResumeSetOpt

Relationship

This parameter is only valid when the switch of SUSPEND/RESUME


process is enabled.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS maximum Retrying Times

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.7.9 Max times of radio access capabilities update retry


(UpdateMax)
Full Name

Max times of radio access capabilities update retry

Abbreviation

UpdateMax

3GPP Name

RA-CAPABILITY-UPDATE-RETRIES

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


This parameter is a BSSGP-layer parameter. When an MS sets up
uplink and downlink TBF, the BSS needs to know the "Radio Access
Capability" of the MS for allocating an appropriate packet channel to it.
If the BSS does not get this information (for example, in the case of
one-step access), a "Radio Access Capability Update" process can be
initiated to get the radio access capability of the MS from the SGSN.
After sending a "Radio Access Capability Update" message to the
SGSN, the "Radio Access Capability Update" process is initiated again if
no "Radio Access Capability Update ACK" or "Radio Access Capability
Update NACK" message is received from the SGSN within BSSGP
T5. "If no response is received from the SGSN after the BSS sends
the "Radio Access Capability Update" message for N times, the BSC
terminates the "Radio Access Capability Update" process and informs
the OMS about the failure. This parameter value, N, indicates the

Description

maximum number of Radio Access Capability Update attempts.

2-170
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Managed Object

BSC
0..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is recommended by the protocol.


Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS maximum Retrying Times

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.7.10 Max times of PFC create retry (DownLoadBssPFCMax)


Full Name

Max times of PFC create retry

Abbreviation

DownLoadBssPFCMax

3GPP Name

DOWNLOAD-BSS-PFC-RETRIES

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"

2-171
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the maximum number of Create PFC attempts.


If the Create BSS PFC message is not received before the timeout of
timer BSSGPT6, the BSS sends the Download BSS PFC message again.
If the BSS does not receive the Create BSS PFC message after sending
the Download BSS PFC message for DownloadBSSPRCMax+1 times, it
terminates the Create BSS PFC process and informs the O&M about this
Description

failure.

Managed Object

BSC
0..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion
Change Mode

The default value is recommended by the protocol.


Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.
Offline
ZGO-01-02-004 Streaming Service Policies
ZGO-01-02-003 Service based QoS

Related features

ZGB-01-02-001 Quality of Service (QoS)

Related Parameters

[BSC]PFCSupport

Relationship

This parameter is only valid when the switch of PFC process is enabled
in the BSC.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS maximum Retrying Times

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-172
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.7.11 Max times of PFC modify retry (ModifyBssPFCMax)


Full Name

Max times of PFC modify retry

Abbreviation

ModifyBssPFCMax

3GPP Name

MODIFY-BSS-PFC-RETRIES

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


This parameter indicates the maximum number of Modify BSS PFC attempts. If the Modify BSS PFC Ack message is not received before the
timeout of timer BSSGPT8, the BSS sends the Modify BSS PFC message
again. If the BSS does not receive the Modify BSS PFC Ack message
after sending the Modify BSS PFC message for ModifyBssPFCMax+1
times, it terminates the Modify BSS PFC process and informs the O&M

Description

about this failure.

Managed Object

BSC
0..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion
Change Mode

The default value is recommended by the protocol.


Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.
Offline
ZGO-01-02-004 Streaming Service Policies
ZGO-01-02-003 Service based QoS

Related features

ZGB-01-02-001 Quality of Service (QoS)

Related Parameters

[BSC]PFCSupport

Relationship

This parameter is only valid when the switch of PFC process is enabled
in the BSC.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS maximum Retrying Times

Parameter Modifying
Version

None
2-173

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

2.7.12 Max of sending PS handover required (PSHoReqMaxNum)


Full Name

Max of sending PS handover required

Abbreviation

PSHoReqMaxNum

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the maximum number of times that the PS
HANDOVER REQUIRED message is sent during PS handover. The PS
HANDOVER REQUIRED message is sent again upon the expiry of timer

Description

T12PsHo.

Managed Object

BSC
1..6

Value Range and Step

Step: 1

Unit

Time

Default Value

Default Value

The default value is an experimental value obtained during the

Configuration Reason

interaction of processes between network elements.

Configuration Rule and

The default value is recommended. The parameters relevant to PS

Adjustment Suggestion

handover, including this parameter, are not in commercial use currently.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS maximum Retrying Times

Parameter Modifying
Version

None

Parameter Modifying
Detail

None
2-174

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.8 GPRS Timer


2.8.1 BVC block/unblock retry time (BssgpT1)
Full Name

BVC block/unblock retry time

Abbreviation

BssgpT1

3GPP Name

T1

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


This parameter is a timer used to supervise the BSSGP block/unblock
process.
The BSS initiates a BVC BLOCK/UNBLOCK process when it is
required to block or unblock a point-to-point BVC due to OAM
intervene or equipment failure. If the SGSN does not return a BVC
BLOCK/UNBLOCK ACK message, the BVC BLOCK/UNBLOCK process
is repeated, and the number of times that the BVC BLOCK/UNBLOCK
message is sent increases by one. The interval between two BVC
BLOCK/UNBLOCK processes is defined as BVC BLOCK/UNBLOCK
RETRY TIME. The BSS tries to send the BVC BLOCK/UNBLOCK
message again when T1 expires but the number of retry times does
not exceed the maximum number of allowable retries. The BVC
block/unblock request is neglected if the number of retry times exceeds
the maximum one when T1 expires.
The following describes when the timer is started and stopped, as well
as the action at expiry of the timer.
Start: The BSC initiates a BVC BLOCK/UNBLOCK process.
Stop: A BVC BLOCK/UNBLOCK ACK/NACK message is received from
the SGSN.
At expiry: The BSC sends the SUSPEND SGSN message for N times.
N, the maximum number of times that the SUSPEND SGSN message

Description

can be sent, can be set.

Managed Object

BSC
10..300

Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value

The default value is set according to the range specified by the protocol

Configuration Reason

and the round trip delay at the Gb interface.

Configuration Rule and


Adjustment Suggestion

Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

2-175
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.2 BVC reset retry time (BssgpT2)


Full Name

BVC reset retry time

Abbreviation

BssgpT2

3GPP Name

T2

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


This parameter is a timer used to supervise the BSSGP reset process.
The BSS initiates a BVC RESET process when a BVC (PTP BVC or
signalling BVC) needs to be reset due to some reasons, for example,
the connection to the Gb interface resumes, the GPRS or EDGE support
of a cell is enabled, or a reset command sent by the OMCR. If the SGSN
does not return a BVC RESET ACK message, the BVC RESET process
is repeated, and the number of times that the BVC RESET message is
sent increases by one. The interval between two BVC RESET processes
is defined as BVC RESET RETRY TIME. The BSS tries to send the BVC
RESET message again when T2 expires but the number of retry times
does not exceed the maximum number of allowable retries. The BSS
set the status of the BVC BLOCK in the database when T2 expires and
the number of times that the BVC RESET message is sent exceeds the
maximum number.
The following describes when the timer is started and stopped, as well
as the action at expiry of the timer.

Description

Start: The BSC initiates a BVC RESET process.

2-176
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Stop: A BVC RESET ACK/NACK message is received from the SGSN.


At expiry: The BSC sends the BVC RESET message for N times. N,
the maximum number of times that the BVC RESET message can be
sent, can be set.
This parameter is changed in V6.20.614a.
Managed Object

BSC
10..1200

Value Range and Step

Step: 1

Unit

100 ms

Default Value

150

Default Value

The default value is set according to the range specified by the protocol

Configuration Reason

and the round trip delay at the Gb interface.

Configuration Rule and


Adjustment Suggestion

Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.3 Suspend retry time (BssgpT3)


Full Name

Suspend retry time

Abbreviation

BssgpT3

3GPP Name

T3

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


2-177

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The Class-B MS shall notify the network to suspend the packet service
when it is going to start a voice service. Upon receiving the SUSPEND
message from the MS, the BSS initiates a SUSPEND SGSN process.
If the SGSN does not return a SUSPEND ACK/NACK message, the
SUSPEND SGSN process is repeated, and the number of times that
the SUSPEND SGSN message is sent increases by one. The interval
between two SUSPEND SGSN processes is defined as SUSPEND
RETRY TIME. The BSS tries to send the SUSPEND SGSN message
again when T3 expires but the number of times that the message is
sent does not exceed the maximum number. The BSS terminates the
SUSPEND SGSN process when T3 expires and the number of times that
the SUSPEND SGSN message is sent exceeds the maximum number.
The following describes when the timer is started and stopped, as well
as the action at expiry of the timer.
Start: The BSC initiates a SUSPEND SGSN process.
Stop: A SUSPEND ACK/NACK message is received from the SGSN.
At expiry: The BSC sends the SUSPEND SGSN message for N times.
N, the maximum number of times that the SUSPEND SGSN message
Description

can be sent, can be set.

Managed Object

BSC
1..100

Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value

The default value is set according to the range specified by the protocol

Configuration Reason

and the round trip delay at the Gb interface.

Configuration Rule and


Adjustment Suggestion

Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]ResumeSetOpt

Relationship

This parameter is only valid when the switch of SUSPEND/RESUME


process is enabled.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-178
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.4 Resume retry time (BssgpT4)


Full Name

Resume retry time

Abbreviation

BssgpT4

3GPP Name

T4

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


This parameter is a timer used to supervise the BSSGP RESUME
process.
The BSS, which adopts the policy of "Notify SGSN to Resume
GPRS Service", initiates a RESUME process to the SGSN when the
GPRS-attached MS leaves the dedicated mode. If the SGSN does
not return a RESUME ACK/NACK message, the RESUME process
is repeated, and the number of times that the RESUME message is
sent increases by one. The interval between two RESUME processes
is defined as RESUME RETRY TIME. The BSS tries to send the
RESUME message again when T4 expires but the number of times
that the message is sent does not exceed the maximum number. The
BSS terminates the RESUME process and notifies the MS to initiate a
ROUTING AREA UPDATE process when T4 expires and the number of
times that the RESUME message is sent exceeds the maximum number.
The following describes when the timer is started and stopped, as well
as the action at expiry of the timer.
Start: The BSC initiates a RESUME process.
Stop: A RESUME ACK/NACK message is received from the SGSN.
At expiry: The BSC sends the MODIFY BSS PFC message for N times.
N, the maximum number of times that the MODIFY BSS PFC message

Description

can be sent, can be set.

Managed Object

BSC
1..100

Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

2-179
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

The default value is set according to the range specified by the protocol

Configuration Reason

and the round trip delay at the Gb interface.

Configuration Rule and


Adjustment Suggestion

Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]ResumeSetOpt

Relationship

This parameter is only valid when the switch of SUSPEND/RESUME


process is enabled.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.5 Access capability update retry time (BssgpT5)


Full Name

Access capability update retry time

Abbreviation

BssgpT5

3GPP Name

T5

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


This parameter is a timer used to supervise the BSSGP RADIO ACCESS
CAPABILITY UPDATE process.
If no RADIO ACCESS CAPABILITY UPDATE ACK/NACK message is
received from the SGSN after the BSS initiates a RADIO ACCESS
CAPABILITY UPDATE process, the RADIO ACCESS CAPABILITY
UPDATE process shall be repeated. The interval between two processes
is defined as RADIO ACCESS CAPABILITY UPDATE RETRY TIME. The
BSS tries to send the RADIO ACCESS CAPABILITY UPDATE message
again when T5 expires but the number of times that the message is

Description

sent does not exceed the maximum number. The BSS terminates the

2-180
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

RADIO ACCESS CAPABILITY UPDATE process when T5 expires and


the number of times that the RADIO ACCESS CAPABILITY UPDATE
message is sent exceeds the maximum number.
The following describes when the timer is started and stopped, as well
as the action at expiry of the timer.
Start: The BSC initiates a RADIO ACCESS CAPABILITY UPDATE
process.
Stop: A RADIO ACCESS CAPABILITY UPDATE ACK/NACK message
is received from the SGSN.
At expiry: The BSC sends the MODIFY BSS PFC message for N times.
N, the maximum number of times that the MODIFY BSS PFC message
can be sent, can be set.
Managed Object

BSC
10..300

Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value

The default value is set according to the range specified by the protocol

Configuration Reason

and the round trip delay at the Gb interface.

Configuration Rule and


Adjustment Suggestion

Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-181
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.8.6 PFC creating retry time (BssgpT6)


Full Name

PFC creating retry time

Abbreviation

BssgpT6

3GPP Name

T6

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


This parameter indicates the retry time for creating PFC.
If no CREATE PFC ACK/NACK message is received from the SGSN
after the BSS initiates a CREATE PFC process, the CREATE PFC
process shall be repeated. The interval between two MODIFY PFC
processes is defined as PFC MODIFY RETRY TIME.
The following describes when the timer is started and stopped, as well
as the action at expiry of the timer.
Start: The BSC initiates a Download PFC process.
Stop: A SGSN CREATE PFC message is received.
At expiry: The BSC sends the MODIFY BSS PFC message for N times.
N, the maximum number of times that the MODIFY BSS PFC message

Description

can be sent, can be set.

Managed Object

BSC
1..100

Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value

The default value is set according to the range specified by the protocol

Configuration Reason

and the round trip delay at the Gb interface.

Configuration Rule and


Adjustment Suggestion

Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]PFCSupport

Relationship

This parameter is only valid when the switch of PFC process is enabled
in the BSC.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-182
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.7 PFC modifying retry time (BssgpT8)


Full Name

PFC modifying retry time

Abbreviation

BssgpT8

3GPP Name

T8

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


If no MODIFY PFC ACK/NACK message is received from the SGSN
after the BSS initiates a MODIFY PFC process, the MODIFY PFC
process shall be repeated. The interval between two MODIFY PFC
processes is defined as PFC MODIFY RETRY TIME.
The following describes when the timer is started and stopped, as well
as the action at expiry of the timer.
Start: The BSC initiates a MODIFY BSS PFC process.
Stop: A SGSN MODIFY BSS PFC ACK message is received.
At expiry: The BSC sends the MODIFY BSS PFC message for N times.
N, the maximum number of times that the MODIFY BSS PFC message

Description

can be sent, can be set.

Managed Object

BSC
1..100

Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value

The default value is set according to the range specified by the protocol

Configuration Reason

and the round trip delay at the Gb interface.

Configuration Rule and


Adjustment Suggestion
Change Mode

Set the parameter in consideration of the default value, the link stability
at Gb interface, and the round trip delay at Gb interface. The default
value is recommended when Gb interface is normal.
Offline
ZGO-01-02-004 Streaming Service Policies
ZGO-01-02-003 Service based QoS

Related features

ZGB-01-02-001 Quality of Service (QoS)

2-183
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

Relationship

[BSC]PFCSupport
This parameter is only valid when the switch of PFC process is enabled
in the BSC.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.8 RIR Timer (TRIR)


Full Name

RIR Timer

Abbreviation

TRIR

3GPP Name

T(RIR)

3GPP Reference

3GPP TS48.018 V6.6.0


This parameter is an expiration timer waiting for the response from the
opposite end after a RAN INFORMATION REQUEST message is sent by
the control end. The timer is started when the control end sends a RAN INFORMATION REQUEST message. It is stopped when a response message is received from the opposite end. If no response is received before
the expiration of the timer, the control end sends a RAN INFORMATION
REQUEST message again, or informs the process failure after sending

Description

the message for RIMRetryTimes times.

Managed Object

BSC
50..300

Value Range and Step

Step: 1

Unit

100 ms

Default Value

50

Default Value
Configuration Reason

The default value is an experimental value.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.


2-184

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Change Mode

Offline

Related features

ZGO-02-02-011 Inter-BSC NACC_FG_20101030

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.9 RI Timer (TRI)


Full Name

RI Timer

Abbreviation

TRI

3GPP Name

T(RI)

3GPP Reference

3GPP TS48.018 V6.6.0


This parameter is an expiration timer waiting for the response from the opposite end after the serving BSS sends a RAN INFORMATION message.
This timer is started when the serving BSS sends a RAN INFORMATION
message, in which the indicator requiring response from the opposite is
set. It is stopped when a response is received from the opposite end. If no
response is received before the expiration of the timer, the serving BSS
sends a RAN INFORMATION message again, or informs the process fail-

Description

ure after sending the message for RIMRetryTimes times.

Managed Object

BSC
50..300

Value Range and Step

Step: 1

Unit

100 ms

Default Value

50

Default Value
Configuration Reason

The default value is an experimental value.

2-185
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

ZGO-02-02-011 Inter-BSC NACC_FG_20101030

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.10 RIAE Timer (TRIAE)


Full Name

RIAE Timer

Abbreviation

TRIAE

3GPP Name

T(RIAE)

3GPP Reference

3GPP TS48.018 V6.6.0


This parameter is an expiration timer waiting for the response from the
opposite end after a RAN INFORMATION APPLICATION ERROR message is sent by the control end. The timer is started when the control
end sends a RAN INFORMATION APPLICATION ERROR message. It is
stopped when a response message is received from the opposite end. If
no response is received before the expiration of the timer, the control end
sends the RAN INFORMATION APPLICATION ERROR message again,
or informs the process failure after sending the message for the specified

Description

times.

Managed Object

BSC
50..300

Value Range and Step

Step: 1

Unit

100 ms

2-186
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Default Value

50

Default Value
Configuration Reason

The default value is an experimental value.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

ZGO-02-02-011 Inter-BSC NACC_FG_20101030

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.11 BVC flow control period (CellFcPer)


Full Name

BVC flow control period

Abbreviation

CellFcPer

3GPP Name

None

3GPP Reference

None
This parameter indicates the period for the statistics of BVC leak rate in
the BVC Flow Control process, that is, the period of long BVC statistics.
To provide a reference for the BVC flow control at the SGSN side,
the BSSGP process at the BSS side performs a periodic statistics on
current BVC leak rate. When the timer used for long statistics times
out, a BVC Flow Control process is initiated without condition. If the
difference between two statistical leak rates exceeds CellFcThs, an
acknowledgement from the SGSN is required before the BVC Flow
Control process is initiated. When the timer used for short statistics

Description

times out, and the difference between two leak rates exceeds CellFcThs,

2-187
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

a BVC Flow Control process is initiated after an acknowledgement is


received from the SGSN.
The following describes when the timer is started and stopped, as well
as the action at expiry of the timer.
Start: When a cell is created.
Stop: When the cell is blocked or deleted.
At expiry: Initiate a BVC FLOW CONTROL process without condition.
Managed Object

BSC
2..65535

Value Range and Step

Step: 1

Unit

10 ms

Default Value

3000

Default Value
Configuration Reason

It is recommended to set the default value to 1000.


The default value 1000 is recommended. A shorter period may increase
the load at the Gb interface. A longer period may cause the failure of
the BVC flow control.

Configuration Rule and


Adjustment Suggestion

A too large parameter value may result in a delay of flow control.


An improperly-set parameter value will cause intermittent download and
influence indexes relevant to throughput efficiency.
Set an appropriate period according to the settings of the SGSN. Make
sure that the parameter value is matching with the SGSN.

Change Mode

Offline

Related features

ZGB-03-05-016 Downlink BVC Flow Control

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-188
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.8.12 MS flow control period (MsFcPer)


Full Name

MS flow control period

Abbreviation

MsFcPer

3GPP Name

None

3GPP Reference

None
This parameter indicates the period for the statistics of MS leak rate
in the MS Flow Control process.
To provide a reference for the flow control at the SGSN side, the BSSGP
process at the BSS side performs a periodic statistics on current leak
rate for each MS. When the timer times out, an MS Flow Control process
is initiated without condition.
The following describes when the timer is started and stopped, as well
as the action at expiry of the timer.
Start: When a downlink LLC frame is received in BSSGP idle state.
Stop: When the transmission of downlink LLC frames is completed.

Description

At expiry: Initiate an MS FLOW CONTROL process without condition.

Managed Object

BSC
2..65535

Value Range and Step

Step: 1

Unit

10 ms

Default Value

3000

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

It is recommended to set the default value to 600.


The default value 600 is recommended. A shorter period may increase
the load at the Gb interface. A longer period may cause the failure of
the MS flow control.

Change Mode

Offline

Related features

ZGB-03-05-017 Downlink MS Flow Control

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

2-189
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.13 Timer that monitors block/unblock procedure (NS_T1)


Full Name

Timer that monitors block/unblock procedure

Abbreviation

NS_T1

3GPP Name

Tns-block

3GPP Reference

3GPP TS48.016 V5.4.0


This parameter is a timer used to supervise the NSVC block/unblock
process on the NS layer. The following describes when the timer is
started and stopped, as well as the action at expiry of the timer.
Start: When the BSC initiates an NS block/unblock process.
Stop: When a block/unblock acknowledgement message is received
from the SGSN.
At expiry: Initiate the NSVC block/unblock process for N times, and
restart the timer. (N depends on NS-BLICK-RETRIES specified by the

Description

protocol).

Managed Object

BSC
10..1200

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value

The default value is set according to the range specified by the protocol

Configuration Reason

and the round trip delay at the Gb interface.

Configuration Rule and


Adjustment Suggestion

10 seconds are long enough as the time delay of a block/unblock


process when the Gb interface is normal. If the delay at the Gb interface
is long, it is recommended to increase the parameter value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

0
2-190

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Negotiation With CN
OMC Access Path

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.14 Timer that monitors reset procedure (NS_T2)


Full Name

Timer that monitors reset procedure

Abbreviation

NS_T2

3GPP Name

Tns-reset

3GPP Reference

3GPP TS48.016 V5.4.0


This parameter is a timer used to supervise the NSVC reset process on
the NS layer. The following describes when the timer is started and
stopped, as well as the action at expiry of the timer.
Start: When the BSC initiates an NSVC reset process.
Stop: When a reset acknowledgement message is received from the
SGSN.
At expiry: Repeat the NSVC reset process until the maximum reset retry

Description

period (NS_T5) is reached, and then restart the timer.

Managed Object

BSC
10..120

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value

The default value is set according to the range specified by the protocol

Configuration Reason

and the round trip delay at the Gb interface.

Configuration Rule and


Adjustment Suggestion

10 seconds are long enough as the time delay of a reset process when
the Gb interface is normal. If the delay at the Gb interface is long, it is
recommended to increase the parameter value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb
2-191

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.15 NC-cycle of NS-VC test process (NS_T3)


Full Name

NC-cycle of NS-VC test process

Abbreviation

NS_T3

3GPP Name

Tns-test

3GPP Reference

3GPP TS48.016 V5.4.0


This parameter is a timer used to supervise the NSVC link test process
on the NS layer. The following describes when the timer is started and
restarted, as well as the action at expiry of the timer.
Start: When the NSVC Reset process is completed (FR), or the
Configuration process is completed (IPGb).
Restart: When an ALIVE ACK message is received from the SGSN.

Description

At expiry: Send an NS ALIVE message.

Managed Object

BSC
10..600

Value Range and Step

Step: 1

Unit

100 ms

Default Value

300

Default Value

The default value is set according to the range specified by the protocol

Configuration Reason

and the round trip delay at the Gb interface.

Configuration Rule and


Adjustment Suggestion

A time period within 30 seconds indicates a normal NSVC link when the
Gb interface is normal. If the NSVC link is not stable, the parameter
value can be appropriately decreased.

Change Mode

Offline

Related features

None

Related Parameters

None

2-192
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.16 Timer that monitors alive process of NSVC (NS_T4)


Full Name

Timer that monitors alive process of NSVC

Abbreviation

NS_T4

3GPP Name

Tns-alive

3GPP Reference

3GPP TS48.016 V5.4.0


This parameter is a timer used to supervise the NSVC alive process on
the NS layer. The following describes when the timer is started and
stopped, as well as the action at expiry of the timer.
Start: When an NS ALIVE message is sent in the test process.
Stop: When an ALIVE ACK message is received from the SGSN.
At expiry: Repeat the alive process for N times (N depends on

Description

NS-ALIVE-RETRIES specified by the protocol).

Managed Object

BSC
30..30

Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value

The default value is set according to the range specified by the protocol

Configuration Reason

and the round trip delay at the Gb interface.

Configuration Rule and


Adjustment Suggestion

Three seconds are long enough as the time delay of an NS alive process
when the Gb interface is normal. If the delay at the Gb interface is long,
it is recommended to increase the parameter value.

Change Mode

Offline

Related features

None
2-193

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.17 Max attempt period of reset (NS_T5)


Full Name

Max attempt period of reset

Abbreviation

NS_T5

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to indicate the maximum retry period of
the NSVC reset process. The following describes when the timer is
started and stopped, as well as the action at expiry of the timer.
Start: When an NSVC reset process is started.
Stop: When a reset acknowledgement is received from the SGSN.

Description

At expiry: Terminate the NSVC reset process.

Managed Object

BSC
1800..1800

Value Range and Step

Step: 1

Unit

100 ms

Default Value

1800

Default Value

The default value is set according to the range specified by the protocol

Configuration Reason

and the round trip delay at the Gb interface.

Configuration Rule and


Adjustment Suggestion
Change Mode

18 seconds are long enough as the time delay of a reset process when
the Gb interface is normal. If the delay at the Gb interface is long, it is
recommended to increase the parameter value.
Offline

2-194
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.18 TFI and USF release timer (T3169)


Full Name

TFI and USF release timer

Abbreviation

T3169

3GPP Name

T3169

3GPP Reference

3GPP TS44.060 V5.19.0


This parameter is timer T3169. In an uplink packet transmission process,
if counter N3101 or N3103 overflows, the BSS starts timer T3169. When
timer T3169 expires, TFI and USF resources are released for reuse.
Start: When the value of counter N3101 equals N3101_MAX, or the
value of counter N3103 equals N3103_MAX.
Stop: None
At expiry: Release the USF and TFI resources.
The counter N3101 equal to N3101_MAX or the counter N3103 equal
to N3103_MAX indicates that the MS does not respond to the BSC any

Description

longer. TFI and USF resources shall be released for reuse in the BSC.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

10 ms

Default Value

500

Default Value
Configuration Reason

The default value is recommended by the protocol.


2-195

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

TFI and USF resources are released for reuse on the network side
when timer T3169 expires. The TBF is forcibly released when the
Configuration Rule and
Adjustment Suggestion

value of N3101 reaches N3101_MAX or the value of N3103 reaches


N3103_MAX. It is unnecessary to set a large parameter value, which
results in a long waiting time and even influences the utilization of
TFI and USF resources. Set the parameter value according to the
recommendation in the protocol.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.19 TBF release timer (T3191)


Full Name

TBF release timer

Abbreviation

T3191

3GPP Name

T3191

3GPP Reference

3GPP TS44.060 V5.19.0


This parameter is timer T3191. The following describes when the timer
is started, restarted, and stopped, as well as the action at the expiry
of the timer.
Start/restart: If the RLC data block to be sent is the last downlink data
block in a downlink packet transmission process, the BSC initiates a
downlink TBF release process by sending an RLC data block, in which
the value of the Final Block Indicator (FBI) equals 1 and the RRBP field
is valid. In this case, the network starts or restarts timer T3191.

Description

Stop:

2-196
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

If the RLC is in ACK mode and the MS finds all downlink blocks have
been received, the MS sends a "Packet Downlink Ack" message whose
FAI equals 1 through the uplink block specified by the RRBP field. The
BSC stops timer T3191 if it receives the "Packet Downlink Ack" message
before the expiry of timer T3191.
If the RCL is in NACK mode, the MS sends a "Packet Control Ack"
message through the uplink block specified by the RRBP field. The
BSC stops timer T3191 if it receives the "Packet Control Ack" message
before the expiry of timer T3191.
At expiry: The BSC releases the TBF.
Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

10 ms

Default Value

500

Default Value
Configuration Reason

The default value is recommended by the protocol.


When sending the last RLC data block of downlink TBF, the BSC sets
FBI (to 1) and RRBP, requires the MS to return a "Packet Downlink
Ack/Nack" message, and starts timer T3191 at the same time. Timer
T3191 is stopped if a response from the MS is received from the required
block. And the downlink transmission is normally completed. If timer

Configuration Rule and

T3191 expires, the downlink TBF is released due to radio failure.

Adjustment Suggestion

A large parameter value can reduce the downlink TBF failure rate.
Keeping TBF for a long time may result in the waste of channel
resources and TFI resources and impacts user experience. Therefore,
in-time release of TBF is recommended.
Use the recommended value specified in Table 13.2.1: Specification of
timers used in GPRS on the Network side of 3GPP TS 04.60.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

2-197
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.20 TBF release time of downlink transmission (T3193)


Full Name

TBF release time of downlink transmission

Abbreviation

T3193

3GPP Name

T3193

3GPP Reference

3GPP TS44.060 V5.19.0


This parameter is timer T3193, which is used for protection purpose
when TBF is released in a packet downlink transmission process. For
more information of T3193, refer to the description of T3191. The
following describes when the timer is started, restarted, and stopped,
as well as the action at the expiry of the timer.
Start/Restart: T3193 is started when the BSC receives a PACKET
DOWNLINK ACK/NACK message with FAI=1 (in RLC ACK mode), or
when T3191 is stopped after the BSC receives a PACKET CONTROL
ACKNOWLEDGE message (in RLC NACK mode).
Stop: The same TFI is used by the newly-established downlink TBF.
At expiry: Release the TFI resource. .
This parameter must be larger than T3192 to ensure that the MS

Description

releases the TFI prior to the BSC.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

10 ms

Default Value

51

Default Value
Configuration Reason

This timer is slightly larger than T3192.

2-198
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Although the delay policy used by T3192/T3193 causes the waste of


some downlink resources, the network can establish a new downlink
TBF in a short time by directly sending a Packet Downlink Assignment
message. If T3192/T3193 expires, the network can only establish a TBF
by initiating a paging process or immediate assignment process (when
Configuration Rule and
Adjustment Suggestion

the MS is in Ready state). In this case, more time is needed for the
establishment of a downlink TBF.
Take the service load in a cell into account when setting T3192/T3193. In
the case of sufficient network resources, set a large parameter value to
reduce the TBF establishment time, increase the data transmission rate,
and thus improve indexes relevant to downlink throughput efficiency.
T3193 must be slightly larger than T3192 because T3193 is a parameter
on the network side.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]T3192

Relationship

Timer T3193 of global resources must be longer than timer T3192 of


all cells.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.8.21 TBF protect time when radio link failure (T3195)


Full Name

TBF protect time when radio link failure

Abbreviation

T3195

3GPP Name

T3195

3GPP Reference

3GPP TS44.060 V5.19.0

2-199
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is timer T3195, which determines the time for protecting
downlink TBF when the MS stops responding due to radio link failure
or cell change.
Start: T3195 is started when the value of N3105 reaches N3105_MAX.
Stop: None
Description

At expiry: The BSC can reuse the TFI.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

10 ms

Default Value

500

Default Value
Configuration Reason

The default value is recommended by the protocol.


TFI is released for reuse on the network side when timer T3195
expires. The TBF is forcibly released when the value of N3105 reaches

Configuration Rule and


Adjustment Suggestion

N3105_MAX. It is unnecessary to set a large parameter value, which


results in a long waiting time and even influences the utilization of TFI
resource.
Use the recommended value specified in Table 13.2.1: Specification of
timers used in GPRS on the Network side of 3GPP TS 04.60.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-200
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.8.22 PS channel delay release timer (PSRelDelay)


Full Name

PS channel delay release timer

Abbreviation

PSRelDelay

3GPP Name

None

3GPP Reference

None
This parameter is a timer indicating the delay time for dynamic
PDCH-to-TCH conversion. The following describes when the timer is
started and stopped, as well as the action at expiry of the timer.
Start: All services (including uplink and downlink) on the PDCH are
released.
Stop: The PDCH is occupied by TBF again.

Description

At expiry: Release PDTCH, and convert it into TCH.

Managed Object

BSC
50..600

Value Range and Step

Step: 1

Unit

100 ms

Default Value

300

Default Value
Configuration Reason

The default value 300 can ensure that the dynamic PS channel can be
converted back into TCH when no service exists on the PS channel
for five seconds.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-201
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.8.23 Guards the PS handover required procedure (T12PsHo)


Full Name

Guards the PS handover required procedure

Abbreviation

T12PsHo

3GPP Name

T12

3GPP Reference

3GPP TS 48.018
This parameter is a timer used to control the time of a PS HANDOVER
REQUIRED process. The timer is started when a PS Handover Required
message is sent. It is stopped when a PS HANDOVER REQUIRED ACK
message or PS HANDOVER REQUIRED NACK message is received.
Upon the expiry of the timer, the PS HANDOVER REQUIRED message

Description

is sent again.

Managed Object

BSC
50..1200

Value Range and Step

Step: 1

Unit

10 ms

Default Value

300

Default Value

The default value is an experimental value obtained during the

Configuration Reason

interaction of processes between network elements.

Configuration Rule and


Adjustment Suggestion

The default value is recommended for this process monitoring timer.


The parameters relevant to PS handover, including this parameter, are
not in commercial use currently.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-202
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.8.24 Guard resource release after sending PS HO command


(TwaitRelInPSHo)
Full Name

Guard resource release after sending PS HO command

Abbreviation

TwaitRelInPSHo

3GPP Name

Internal

3GPP Reference

None
The parameter specifies the waiting time for the release of resources
after a PS Handover Command message is sent.
This timer is started after a PS HANDOVER COMMAND message
is sent to the MS. It is stopped after a DELETE BSS PFC message
is received from the SGSN, or a HANDOVER COMPLETE message
is received from the target cell. Upon the expiry of the timer, a PS

Description

HANDOVER CANCEL message is sent to the SGSN.

Managed Object

BSC
100..1000

Value Range and Step

Step: 1

Unit

10 ms

Default Value

300

Default Value

The default value is an experimental value obtained during the

Configuration Reason

interaction of processes between network elements.

Configuration Rule and


Adjustment Suggestion

The default value is recommended for this process monitoring timer.


The parameters relevant to PS handover, including this parameter, are
not in commercial use currently.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Timer

Parameter Modifying
Version

None

2-203
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

2.8.25 Downlink Delay time in signal TBF Mode (SigTBFDlDelay


Time)
Full Name

Downlink Delay time in signal TBF Mode

Abbreviation

SigTBFDlDelayTime

3GPP Name

None
TS 44.060: Radio Link Control/Medium Access Control (RLC/MAC) pro-

3GPP Reference

tocol"

Description

This parameter specifies the downlink delay of the signaling TBF.

Managed Object

BSC
500..4000

Value Range and Step

Step: 1

Unit

ms

Default Value

1000

Default Value
Configuration Reason

The DL delay in signaling TBF mode is set to half the DL delay in data
TBF mode, because the traffic transmitted by the signaling TBF is low
and longer delay can lead to a waste of resources.

Configuration Rule and

It is not recommended to modify the value. Modification can affect the

Adjustment Suggestion

service quality.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


SetBSC Function->GPRS Timer2

Parameter Modifying
Version

iBSCV6.20.712b

2-204
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Detail

New

2.8.26 Extendable uplink TBF time in signal TBF Mode


(SigTBFExtUlTime)
Full Name

Extendable uplink TBF time in signal TBF Mode

Abbreviation

SigTBFExtUlTime

3GPP Name

None
TS 44.060: Radio Link Control/Medium Access Control (RLC/MAC) pro-

3GPP Reference

tocol"
This parameter specifies the extendable uplink TBF time in signal TBF

Description

Mode.

Managed Object

BSC
0..3000

Value Range and Step

Step: 1

Unit

ms

Default Value

800

Default Value
Configuration Reason

The UL extension time in signaling TBF mode is set to half the same
time in data TBF mode, because the traffic transmitted by the signaling
TBF is low and longer extension time can lead to a waste of resources.

Configuration Rule and

It is not recommended to modify the value. Modification can affect the

Adjustment Suggestion

service quality.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


SetBSC Function->GPRS Timer2

Parameter Modifying
Version

iBSCV6.20.712b

2-205
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

2.8.27 Synchronization timer that ensures source BSS receives


both PS and CS responses (T23)
The parameter is not used in this version.

2.8.28 Synchronization timer that ensures target BSS receives both


PS and CS requests (T24)
The parameter is not used in this version.

2.8.29 T3197 (T3197)


The parameter is not used in this version.

2.9 AMR Half Method Parameters


2.9.1 AMR Half Active Codec Set (AmrHalfAcs)
Full Name

AMR Half Active Codec Set

Abbreviation

AmrHalfAcs

3GPP Name

AMR Active Codec Set

3GPP Reference

45.009
The code has eight bits. Bits 6 to 8 are reserved. 7.40 kbit/s is bit 5,
6.70 kbit/s bit 4, 5.9 kbit/s is bit 3, 5.15 kbit/s is bit 2, and 4.75 kbit/s
bit 1. Yes stands for 1, that is, including this speech coding mode. No
stands for 0, that is, excluding this speech coding mode. At most four
coding modes can be set.
When interface A is in IP mode, ACS is decided by the MSC and this

Description

parameter is invalid.

Managed Object

BSC
The value is Yes or No for 4.75 kbit/s, 5.15 kbit/s, 5.90 kbit/s, 6.70 kbit/s,

Value Range and Step

and 7.40 kbit/s.

Unit

None
The default value is "Yes, No, Yes, No, Yes", that is, 00010101. In this
case, you can export the decimal number "21" from the network planning

Default Value

and optimization table.

2-206
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

Under TrFO configuration, 5.15k is unavailable to the rate set supported


by CN. This default value is configured so as to not affect the success
rate of TFO establishment when AMR+TFO is configured.
Generally, high rates are used along with low rates. When a cell has
good radio signal quality, you can select high rates only. Otherwise, you
can select low rates only.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[BSC]AmrStartMode
When only one of the five bits of this parameter is set to No, the value
range is 1 to 4.
When two of the five bits of this parameter are set to No, the value
range is 1 to 3.

Relationship

When three of the five bits of this parameter are set to No, the value
range is 1 to 2.
When four of the five bits of this parameter are set to No, the value
range is 1.
When the five bits of this parameter are all set to No, the value range is
null.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->AMR Half Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.9.2 Thresholds of AMR (AmrThresholds)


Full Name

Thresholds of AMR

Abbreviation

AmrThresholds

3GPP Name

threshold

3GPP Reference

45.009

2-207
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The parameter AmrThresholds includes five elements: AmrThresholds1,


AmrThresholds2, AmrThresholds3, AmrThresholds4, and
AmrThresholds5, which meet the following requirements:
AmrThresholds1 AmrThresholds2 AmrThresholds3
AmrThresholds4 AmrThresholds5
AmrThresholds1 + AmrHysteresis1 AmrThresholds2 +
AmrHysteresis2AmrThresholds3 + AmrHysteresis3 AmrThresholds4
+ AmrHysteresis4 AmrThresholds5 + AmrHysteresis5
When CIR is more than AmrThresholdsN+AmrHysteresisN, the speech
coding rate will be changed to mode N+1. When CIR is less than
Description

AmrThresholdsN, the speech coding rate will be changed to mode N.

Managed Object

BSC
The value rage is 0 to 63 in modes 1, 2, 3, 4, and 5.
0: 0.0 dB
1: 0.5 dB
2: 1.0 dB
...

Value Range and Step

63: 31.5 dB

Unit

0.5 dB

Default Value

[18, 20, 23, 26, 30]

Default Value

The default value is set to improve the performance of AMR function.

Configuration Reason
Configuration Rule and

Generally, you do not have to adjust the setting of this parameter unless

Adjustment Suggestion

the FER measured by the BTS exceeds 1%.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[BSC]AmrHysteresis
AmrThresholds1 AmrThresholds2 AmrThresholds3
AmrThresholds4 AmrThresholds5

Relationship

AmrThresholds1 + AmrHysteresis1 AmrThresholds2 +


AmrHysteresis2AmrThresholds3 + AmrHysteresis3 AmrThresholds4
+ AmrHysteresis4 AmrThresholds5 + AmrHysteresis5

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->AMR Half Method Paras

2-208
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.9.3 Hysteresis of AMR (AmrHysteresis)


Full Name

Hysteresis of AMR

Abbreviation

AmrHysteresis

3GPP Name

hysteresis

3GPP Reference

45.009
The parameter AmrThresholds includes five elements: AmrThresholds1,
AmrThresholds2, AmrThresholds3, AmrThresholds4, and
AmrThresholds5, which meet the following requirements:
AmrThresholds1 AmrThresholds2 AmrThresholds3
AmrThresholds4 AmrThresholds5
AmrThresholds1 + AmrHysteresis1 AmrThresholds2 +
AmrHysteresis2AmrThresholds3 + AmrHysteresis3 AmrThresholds4
+ AmrHysteresis4 AmrThresholds5 + AmrHysteresis5
When CIR is more than AmrThresholdsN+AmrHysteresisN, the speech
coding rate will be changed to mode N+1. When CIR is less than

Description

AmrThresholdsN, the speech coding rate will be changed to mode N.

Managed Object

BSC
The value rage is 0 to 15 in modes 1, 2, 3, 4, and 5.
0: 0.0 dB
1: 0.5 dB
2: 1.0 dB
...

Value Range and Step

15: 7.5 dB

Unit

0.5 dB

Default Value

[3, 3, 3, 4, 4]

Default Value
Configuration Reason

The default value is set to improve the performance of AMR function.


By checking the frequency of rate adjustments (through tests, analyses,

Configuration Rule and

or AMR rate monitoring tools), you can decide whether this parameter

Adjustment Suggestion

is set properly. When the rate is adjusted too frequently, you can set
the parameter to a higher value.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)


2-209

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

[BSC]AmrThresholds
AmrThresholds1 + AmrHysteresis1 AmrThresholds2 + AmrHysteresis2

Relationship

AmrThresholds3 + AmrHysteresis3 AmrThresholds4 +


AmrHysteresis4 AmrThresholds5 + AmrHysteresis5

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->AMR Half Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.9.4 Initial codec mode (IsAmrlCM)


Full Name

Initial codec mode

Abbreviation

IsAmrlCM

3GPP Name

Initial Codec Mode Indicator

3GPP Reference

45.009
This parameter decides which one, the coding mode specified in
Startmode or the default initial coding mode specified in the protocol
45.009, is used as the initial AMR speech coding mode.
When one mode is used, the corresponding rate is used as the initial
coding mode.
When two or three modes are used, the lowest rate is used as the
initial coding mode.
When four modes are used, the second lowest rate is used as the initial
coding mode.
When interface A is in IP mode, this parameter is not used. The initial
coding mode depends on IpaAMRStartMode in the system control

Description

parameters.

Managed Object

BSC

Value Range and Step

Start-mode codec, Initial codec mode

Unit

None

Default Value

Start-mode codec

2-210
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Default Value
Configuration Reason

In the default mode, the initial coding mode can be set as needed.
In good radio network conditions, Start-mode codec and high-rate

Configuration Rule and


Adjustment Suggestion

coding modes are recommended.


In poor radio network conditions, you can set this parameter to "Initial
codec mode", that is, the default initial rate specified in the protocol.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[BSC]AmrStartMode

Relationship

AmrStartMode is valid only when IsAmrlCM is set to "Start-mode codec".

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->AMR Half Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.9.5 Start mode (AmrStartMode)


Full Name

Start mode

Abbreviation

AmrStartMode

3GPP Name

Start Mode

3GPP Reference

44.018

Description

Startmode codec mode

Managed Object

BSC

2-211
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The value range is described as follows:


1: The coding mode with the lowest code rate is selected as the initial
coding mode.
2: If there is more than one coding mode, the coding mode with the
second lowest code rate will be selected.
3: If there are more than two coding modes, the coding mode with the
third lowest code rate will be selected.
4: If there are more than three coding modes, the coding mode with the
Value Range and Step

fourth lowest code rate will be selected.

Unit

None
This parameter is set as the maximum rate in accordance with the number
of the current selected rates. For example, it is set to 4 if the full rate
is configured with 4 coding modes, and the maximum coding mode is

Default Value

selected as the initial rate.


Previously, the minimum coding mode is used in which the MOS value

Default Value
Configuration Reason

increased from the lower value to the stabilized value takes a long period
of time, which is due to the limitation of the current rate adjustment
mechanision of the version. In this case, the initial coding mode is
changed into the maximum coding mode.

Configuration Rule and

In good radio network conditions, high initial rates can be used to

Adjustment Suggestion

improve voice quality.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[BSC]AmrHarfAcs
[BSC]IsAmrlCM
When only one of the five bits of the parameter AmrHarfAcs is set to No,
the value range is 1 to 4.
When two of the five bits of the parameter AmrHarfAcs are set to No,
the value range is 1 to 3.
When three of the five bits of the parameter AmrHarfAcs are set to No,

Relationship

the value range is 1 to 3.


When four of the five bits of the parameter AmrHarfAcs are set to No,
the value range is 1.
When the five bits of the parameter AmrHarfAcs are all set to No, the
value range is null.
AmrStartMode is valid only when IsAmrlCM is set to "Start-mode codec".

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-212
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->AMR Half Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.9.6 Enable noise control (IsAmrNscb)


Full Name

Enable noise control

Abbreviation

IsAmrNscb

3GPP Name

Noise Suppression Control Bit

3GPP Reference

44.018
This parameter decides whether to disable the AMR noise control
function at the MS side, that is, whether to suppress the background
noise and keep the original voice quality. Noise suppression is a function
at the MS side.
No: Noise suppression enabled.

Description

Yes: Noise suppression disabled.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

Enabling noise suppression can minimize noise and improve voice

Configuration Reason

quality.

Configuration Rule and


Adjustment Suggestion

Generally, it is recommended to enable the noise suppression function.


When voice quality problems occur, you should check the setting of
this parameter.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

None

Relationship

None

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
2-213

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->AMR Half Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.10 AMR Full Method Parameters


2.10.1 AMR full Active Codec Set (AmrFullAcs)
Full Name

AMR full Active Codec Set

Abbreviation

AmrFullAcs

3GPP Name

AMR Active Codec Set

3GPP Reference

45.009
The code has eight bits. 12.2 kbit/s is bit 8, 10.2 kbit/s bit 7, 7.95 kbit/s
bit 6, 7.40 kbit/s bit 5, 6.70 kbit/s bit 4, 5.9 kbit/s bit 3, 5.15 kbit/s bit 2,
and 4.75 kbit/s bit 1. Yes stands for 1, that is, including this speech
coding mode. No stands for 0, that is, excluding this speech coding
mode. At most four coding modes can be set.
When interface A is in IP mode, ACS is decided by the MSC and this

Description

parameter is invalid.

Managed Object

BSC
The value is Yes or No for 4.75 kbit/s, 5.15 kbit/s, 5.90 kbit/s, 6.70 kbit/s,

Value Range and Step

7.40 kbit/s, 7.95 kbit/s, 10.2 kbit/s, and 12.2 kbit/s.

Unit

None
The default value is "Yes, No, Yes, No, Yes, No, No, Yes", that is,
10010101. In this case, you can export the decimal number "149" from

Default Value
Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

the network planning and optimization table.


Under TrFO configuration, 5.15k is unavailable to the rate set supported
by CN. This default value is configured so as to not affect the success
rate of TFO establishment when AMR+TFO is configured.
Generally, high rates are used along with low rates. When a cell has
good radio signal quality, you can select high rates only. Otherwise, you
can select low rates only.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

2-214
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related Parameters

[BSC]AmrStartMode
When four of the eight bits of this parameter are set to No, the value
range is 1 to 4.
When five of the eight bits of this parameter are set to No, the value
range is 1 to 3.

Relationship

When six of the eight bits of this parameter are set to No, the value
range is 1 to 2.
When seven of the eight bits of this parameter are set to No, the value
range is 1.
When the eight bits of this parameter are all set to No, the value range is
null.

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->AMR Full Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.10.2 Thresholds of AMR (AmrThresholds)


Full Name

Thresholds of AMR

Abbreviation

AmrThresholds

3GPP Name

threshold

3GPP Reference

45.009
This parameter includes seven elements: AmrThresholds1,
AmrThresholds2, AmrThresholds3, AmrThresholds4, AmrThresholds5,
AmrThresholds6, and AmrThresholds7, which meet the following
requirements:
AmrThresholds1 AmrThresholds2 AmrThresholds3
AmrThresholds4 AmrThresholds5 AmrThresholds6
AmrThresholds7, AmrThresholds1 + AmrHysteresis1 AmrThresholds2
+ AmrHysteresis2 AmrThresholds3 + AmrHysteresis3
AmrThresholds4 + AmrHysteresis4 AmrThresholds5 + AmrHysteresis5
AmrThresholds6 + AmrHysteresis6 AmrThresholds7 +

Description

AmrHysteresis7

2-215
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

BSC
The value rage is 0 to 63 in modes 1, 2, 3, 4, 5, 6 and 7.
0: 0.0 dB
1: 0.5 dB
2: 1.0 dB
...

Value Range and Step

63: 31.5 dB

Unit

0.5 dB

Default Value

[13, 14, 15, 17, 18, 20, 23]

Default Value
Configuration Reason

The default value is set to improve the performance of AMR function.

Configuration Rule and

Generally, you do not have to adjust the setting of this parameter unless

Adjustment Suggestion

the FER measured by the BTS exceeds 1%.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[BSC]AmrHysteresis
This parameter includes seven elements: AmrThresholds1,
AmrThresholds2, AmrThresholds3, AmrThresholds4, AmrThresholds5,
AmrThresholds6, and AmrThresholds7, which meet the following
requirements:
AmrThresholds1 AmrThresholds2 AmrThresholds3

Relationship

AmrThresholds4 AmrThresholds5 AmrThresholds6


AmrThresholds7, AmrThresholds1 + AmrHysteresis1 AmrThresholds2
+ AmrHysteresis2 AmrThresholds3 + AmrHysteresis3
AmrThresholds4 + AmrHysteresis4 AmrThresholds5 + AmrHysteresis5
AmrThresholds6 + AmrHysteresis6 AmrThresholds7 +
AmrHysteresis7

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->AMR Full Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-216
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.10.3 Hysteresis of AMR (AmrHysteresis)


Full Name

Hysteresis of AMR

Abbreviation

AmrHysteresis

3GPP Name

hysteresis

3GPP Reference

45.009
This parameter includes seven elements: AmrHysteresis1,
AmrHysteresis2, AmrHysteresis3, AmrHysteresis4, AmrHysteresis5,
AmrHysteresis6, and AmrHysteresis7, which meet the following
requirements:
AmrThresholds1 + AmrHysteresis1 AmrThresholds2 + AmrHysteresis2
AmrThresholds3 + AmrHysteresis3 AmrThresholds4 +
AmrHysteresis4 AmrThresholds5 + AmrHysteresis5 AmrThresholds6

Description

+ AmrHysteresis6 AmrThresholds7 + AmrHysteresis7

Managed Object

BSC
The value rage is 0 to 15 in modes 1, 2, 3, 4, 5, 6 and 7.
0: 0.0 dB
1: 0.5 dB
2: 1.0 dB
...

Value Range and Step

15: 7.5 dB

Unit

0.5 dB

Default Value

[3, 3, 3, 3, 3, 4, 4]

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is set to improve the performance of AMR function.


By checking the frequency of rate adjustments, you can decide whether
this parameter is set properly. When the rate is adjusted too frequently,
you can set the parameter to a higher value.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[BSC]AmrThresholds
This parameter includes seven elements: AmrHysteresis1,
AmrHysteresis2, AmrHysteresis3, AmrHysteresis4, AmrHysteresis5,
AmrHysteresis6, and AmrHysteresis7, which meet the following

Relationship

requirements:
AmrThresholds1 + AmrHysteresis1 AmrThresholds2 + AmrHysteresis2
AmrThresholds3 + AmrHysteresis3 AmrThresholds4 +
AmrHysteresis4 AmrThresholds5 + AmrHysteresis5 AmrThresholds6
+ AmrHysteresis6 AmrThresholds7 + AmrHysteresis7

2-217
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->AMR Full Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.10.4 Initial codec mode (IsAmrICM)


Full Name

Initial codec mode

Abbreviation

IsAmrICM

3GPP Name

Initial Codec Mode Indicator

3GPP Reference

45.009
This parameter decides which one, the coding mode specified in
Startmode or the default initial coding mode specified in the protocol
45.009, is used as the initial AMR speech coding mode.
When one mode is used, the corresponding rate is used as the initial
coding mode.
When two or three modes are used, the lowest rate is used as the
initial coding mode.
When four modes are used, the second lowest rate is used as the initial
coding mode.
When interface A is in IP mode, this parameter is not used. The initial
coding mode depends on IpaAMRStartMode in the system control

Description

parameters.

Managed Object

BSC

Value Range and Step

Start-mode codec, Initial codec mode

Unit

None

Default Value

Start-mode codec

Default Value
Configuration Reason

In the default mode, the initial coding mode can be set as needed.

Configuration Rule and

Generally, you can set this parameter to "Initial codec mode", that is, the

Adjustment Suggestion

default initial rate specified in the protocol.

Change Mode

Offline
2-218

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[BSC]AmrStartMode

Relationship

AmrStartMode is valid only when IsAmrlCM is set to "Start-mode codec".

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->AMR Full Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.10.5 Start mode (AmrStartMode)


Full Name

Start mode

Abbreviation

AmrStartMode

3GPP Name

Start Mode

3GPP Reference

44.018

Description

Startmode codec mode

Managed Object

BSC
When four of the eight bits of the parameter AmrFullAcs are set to No,
the value range is 1 to 4.
When five of the eight bits of the parameter AmrFullAcs are set to No,
the value range is 1 to 3.
When six of the eight bits of the parameter AmrFullAcs are set to No,
the value range is 1 to 2.
When seven of the eight bits of the parameter AmrFullAcs are set to
No, the value range is 1.
When the eight bits of the parameter AmrFullAcs are all set to No, the
value range is null.
The value range is described as follows:
1: The coding mode with the lowest code rate is selected as the initial
coding mode.
2: If there is more than one coding mode, the coding mode with the

Value Range and Step

second lowest code rate will be selected.

2-219
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3: If there are more than two coding modes, the coding mode with the
third lowest code rate will be selected.
4: If there are more than three coding modes, the coding mode with the
fourth lowest code rate will be selected.
Unit

None
This parameter is set as the maximum rate in accordance with the number
of the current selected rates. For example, it is set to 4 if the full rate
is configured with 4 coding modes, and the maximum coding mode is

Default Value

selected as the initial rate.


Previously, the minimum coding mode is used in which the MOS value

Default Value
Configuration Reason

increased from the lower value to the stabilized value takes a long period
of time, which is due to the limitation of the current rate adjustment
mechanision of the version. In this case, the initial coding mode is
changed into the maximum coding mode.

Configuration Rule and

High initial rates can be used in cells that have good radio network

Adjustment Suggestion

conditions.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[BSC]AmrHarfAcs
[BSC]IsAmrlCM
When four of the eight bits of this parameter are set to No, the value
range is 1 to 4.
When five of the eight bits of this parameter are set to No, the value
range is 1 to 3.
When six of the eight bits of this parameter are set to No, the value

Relationship

range is 1 to 2.
When seven of the eight bits of this parameter are set to No, the value
range is 1.
When the eight bits of this parameter are all set to No, the value range is
null.
AmrStartMode is valid only when IsAmrlCM is set to "Start-mode codec".

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->AMR Full Method Paras

Parameter Modifying
Version

None

2-220
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Detail

None

2.10.6 Enable noise control (IsAmrNscb)


Full Name

Enable noise control

Abbreviation

IsAmrNscb

3GPP Name

Noise Suppression Control Bit

3GPP Reference

44.018
This parameter decides whether to disable the AMR noise control
function at the MS side, that is, whether to suppress the background
noise and keep the original voice quality. Noise suppression is a function
at the MS side.
No: Noise suppression enabled.

Description

Yes: Noise suppression disabled.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

Enabling noise suppression can minimize noise and improve voice

Configuration Reason

quality.

Configuration Rule and


Adjustment Suggestion

Generally, it is recommended to enable the noise suppression function.


When voice quality problems occur, you should check the setting of
this parameter.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

None

Relationship

None

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->AMR Full Method Paras

Parameter Modifying
Version

None
2-221

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

2.11 GPRS Other Parameters 1


2.11.1 Cn (Cn)
Full Name

Cn

Abbreviation

Cn

3GPP Name

None

3GPP Reference

None
This parameter is a counter used as a criterion for increasing the channel
coding level.
Being different from CS channels, for which only one coding scheme
can be used, GPRS data blocks can use four channel-coding schemes
(CS-1 to CS-4). The data rates corresponding to these four coding
schemes (CS-1, CS-2, CS-3, and CS-4) are 9.05 kbps, 13.4 kbps, 15.6
kbps, and 21.4 kbps. The lower-level coding scheme provides higher
error correction capability and lower data throughput. Different coding
schemes can be used for different timeslots and even different TBFs.
The network selects the coding mode dynamically according to the data
rate requirement and radio transmission quality at the transmission of
the GPRS data, to reach maximum radio throughput. The probability
of retransmission of error radio blocks is small when the radio
transmission quality in the network is good. In this case, a coding
scheme accommodating more information (that is, a higher-level coding
scheme) is recommended.
Increase the coding scheme by one level when the count of continuous
correctly-transmitted data blocks of the TBF (uplink and downlink) , for
which the coding scheme CSn (1n3) is used, exceeds the preset value
of the parameter Cn[n-1].
The subscripts 1, 2, and 3 correspond to three parameters for coding
scheme switching between CS1 and CS2, CS2 and CS3, and CS3 and

Description

CS4.

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

85

2-222
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Default Value
Configuration Reason

Based on the result of system emulation, it is deemed that a BLER in the


range from 15% to 25% is acceptable. Increasing the coding scheme
level when a BLER is lower than 15% can improve the transmission rate.
A large parameter value, making it difficult to increase the coding scheme
level, can prevent rate decrease caused by improper increasing of
coding scheme level and facilitate the reduction of GPRS TBF drop rate.

Configuration Rule and


Adjustment Suggestion

A small parameter value makes it easy to fulfill the criterion for increasing
the coding scheme level.
A large parameter value is recommended to ensure that the increase of
coding scheme level is only allowed when the BLER is low. In this case,
the increasing of coding scheme level can improve the indexes relevant
to GPRS service throughput (not EDGE).

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.11.2 Nn (Nn)
Full Name

Nn

Abbreviation

Nn

3GPP Name

None

3GPP Reference

None

2-223
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is a counter used as a criterion for decreasing the


channel coding level. It is used on the RLC/MAC layer of BRP.
Being different from CS channels, for which only one coding scheme
can be used, GPRS data blocks can use four channel-coding schemes
(CS-1 to CS-4). The data rates corresponding to these four coding
schemes (CS-1, CS-2, CS-3, and CS-4) are 9.05 kbps, 13.4 kbps, 15.6
kbps, and 21.4 kbps. The lower-level coding scheme provides higher
error correction capability and lower data throughput.
User can choose different coding modes for each timeslot or even each
TBF. In the GPRS data transport process, the network should select
appropriate coding modes in a dynamic manner depending on the
requirement for data rate and the radio transmission quality to achieve
the maximum radio throughput.
The coding mode with stronger anti-interference capability (that is, low
level coding mode) must be used when the radio transmission quality
is poor. Decrease the coding scheme by one level when the count of
lost continuous data blocks reaches Xn[n-2]% of Nn[n-2] data blocks
on the TBF (uplink and downlink), for which the coding scheme CSn
(2n4) is used.
The subscripts 1, 2, and 3 correspond to three parameters for coding
scheme switching between CS1 and CS2, CS2 and CS3, and CS3 and
Description

CS4.

Managed Object

BSC
0..255

Value Range and Step

Step: 1

Unit

None

Default Value

20

Default Value

The parameter value 20 is recommended in consideration of the

Configuration Reason

sensitivity and precision of rate adjustment.


If the parameter value is large, more transmitted data blocks are involved
and the stability of coding scheme adjustment can be improved.

Configuration Rule and

If the parameter value is small, the coding scheme can be adjusted in

Adjustment Suggestion

time with the change of the radio environment.


An appropriate parameter value can improve the indexes relevant to
GPRS service throughput (not EDGE).

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

2-224
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.11.3 Xn (Xn)
Full Name

Xn

Abbreviation

Xn

3GPP Name

None

3GPP Reference

None
This parameter indicates the threshold used as a criterion for decreasing
the channel coding level. It is used on the RLC/MAC layer of BRP.
Being different from CS channels, for which only one coding scheme
can be used, GPRS data blocks can use four channel-coding schemes
(CS-1 to CS-4). The data rates corresponding to these four coding
schemes (CS-1, CS-2, CS-3, and CS-4) are 9.05 kbps, 13.4 kbps, 15.6
kbps, and 21.4 kbps. The lower-level coding scheme provides higher
error correction capability and lower data throughput.
User can choose different coding modes for each timeslot or even each
TBF. In the GPRS data transport process, the network should select
appropriate coding modes in a dynamic manner depending on the
requirement for data rate and the radio transmission quality to achieve
the maximum radio throughput.
The coding mode with stronger anti-interference capability (that is, low
level coding mode) must be used when the radio transmission quality
is poor. Decrease the coding scheme by one level when the count of
lost continuous data blocks reaches Xn[n-2]% of Nn[n-2] data blocks
on the TBF (uplink and downlink), for which the coding scheme CSn
(2n4) is used.
The subscripts 1, 2, and 3 correspond to three parameters for coding
scheme switching between CS1 and CS2, CS2 and CS3, and CS3 and

Description

CS4.

Managed Object

BSC

2-225
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0..100
Value Range and Step

Step: 1

Unit

Default Value

25

Default Value

In a common radio environment, a retransmission rate within the range

Configuration Reason

from 15% to 25% is acceptable.


A large parameter value makes it difficult to fulfill the criterion for
decreasing the coding scheme level.
A small parameter value makes it easy to fulfil the criteria for decreasing
the coding scheme level.

Configuration Rule and

A small parameter value is recommended to ensure that the coding

Adjustment Suggestion

scheme level can be decreased when the BLER is high, preventing too
low transmission rate caused by the delay of coding scheme adjustment.
The in-time adjustment of coding scheme can reduce the GPRS TBF
drop rate and improve the indexes relevant to GPRS service throughput
(not EDGE).

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.11.4 Max allowed number of continous losses of uplink data


blocks (N3101)
Full Name

Max allowed number of continous losses of uplink data blocks

Abbreviation

N3101

3GPP Name

N3101
2-226

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

3GPP Reference

3GPP TS44.060 V5.19.0


This parameter is counter N3101, which is used on the RLC/MAC layer
of PCU.
In a packet uplink transmission process, the BSS allocates a USF
to each uplink block (corresponding to a uplink TBF). If the network
correctly receives data from the specified uplink block for a USF, N3101
is cleared for the TBF. If the number of times that the lost of data in
the specified uplink block occurs exceeds N3101, timer T3169 will be
started. The network can use the TFI and USF resources again after

Description

T3169 expires.

Managed Object

BSC

Value Range and Step

9...255

Unit

None

Default Value

50

Default Value

The default value is set to reduce the number of exception TBF releases

Configuration Reason

caused by the overflow of N3101 and thus improve the network quality.
The smaller the parameter value is, the higher tolerance on uplink
exception the network has, and the higher the probability of exception
uplink TBF release is. If the parameter value is too large, the network
still allocates uplink resources to the MS because the uplink block
receiving failure is caused by the MS itself, which results in the waste

Configuration Rule and


Adjustment Suggestion

of system resources. In the basic measurement of PS, the number of


exception uplink TBF releases upon N3101 overflow records some
causes of these uplink TBF releases, which generally are poor link
quality at Abis interface, poor radio interface quality, improper network
coverage, and some actions of the MS (for example, cell reselection).
After the radio environment is improved, the overflow threshold of N3101
can be appropriately increased to reduce the number of exception uplink
TBF releases and thus improve the network quality at a certain extent.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-227
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.11.5 Times of packet uplink ACK/NACK retries (N3103)


Full Name

Times of packet uplink ACK/NACK retries

Abbreviation

N3103

3GPP Name

N3103

3GPP Reference

3GPP TS44.060 V5.19.0


This parameter is counter N3101, which is used on the RLC/MAC layer
of PCU.
In a packet uplink transmission process, after detecting the completion
of uplink TBF (CV=0, V(Q)=V(R)) and receiving all RLC data blocks,
the network sends a "Packet Uplink ACK/NACK" message with FAI=1,
inserts a valid RRBP field in the header of the RLC/MAC control block,
and then clears counter N3103.
Upon receiving a "Packet Uplink ACK/NACK" message with FAI=1 from
the network side, the MS sends a "Packet Control ACK" message in the
block specified by RRBP and release the TBF.
If the network fails to receive the "Packet Control ACK" message from
the radio block specified by RRBP, N3103 increases by 1 and the
"Packet Uplink ACK/NACK" is retransmitted.
The network starts T3169 timer if the value of N3103 exceeds the
limiting N3103max. The network can use the TFI and USF resources

Description

again after T3169 expires.

Managed Object

BSC

Value Range and Step

0...255

Unit

None

Default Value

10

Default Value
Configuration Reason

The default value 10 is recommended in consideration of improving


the network quality by reducing the number of exception uplink TBF
releases due to N3103 overflow, and reducing the delay of TBF release.

2-228
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

The smaller the parameter value is, the higher tolerance on uplink
exception the network has, and the higher the probability of exception
uplink TBF release is. If the parameter value is too small, the network
still allocates uplink resources to the MS because the network fails
Configuration Rule and
Adjustment Suggestion

to receive the correct PACKET CONTROL ACKKNOWLEDGEMENT


message due to poor radio interface quality or some actions of the
MS, which results in the waste of system resources. Adjust the value
of N3103 appropriately according to the actual situation of the network
(for example, radio interface quality, transmission link quality, and the
factor of the MS itself) to reduce the number of exception TBF releases
caused by N3103 overflow.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.11.6 Max allowed number of continous losses of uplink RLC/MAC


control message (N3105)
Max allowed number of continous losses of uplink RLC/MAC control mesFull Name

sage

Abbreviation

N3105

3GPP Name

N3105

3GPP Reference

3GPP TS44.060 V5.19.0

2-229
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is counter N3105, which is used on the RLC/MAC layer


of PCU.
When the network sends the downlink RLC block or RLC/MAC control
block of the allocated RRBP and receives a valid RLC/MAC control
message from the MS in a TBF, the counter N3105 is reset. If the
network does not receive the RLC/MAC control block from the allocated
block, the counter N3105 is increased by 1. When N3105 reaches
N3105_MAX, the TBF is released. N3105_MAX depends on the settings
Description

on the network side.

Managed Object

BSC

Value Range and Step

0...255

Unit

None

Default Value

15

Default Value
Configuration Reason

The default value is set to reduce the number of exception downlink


TBF releases caused by the overflow of N3105 and thus improve the
network quality.
The smaller the parameter value is, the higher tolerance on uplink
exception the network has, and the higher the probability of exception
downlink TBF release is. If the parameter value is too small, the network
still allocates radio resources to the MS because the network fails to

Configuration Rule and

receive the correct PACKET (EGPRS) DOWNLINK ACK message due to

Adjustment Suggestion

some actions of the MS, which results in the waste of system resources.
Adjust the value of N3105 appropriately according to the actual situation
of the network (for example, radio interface quality, transmission link
quality, and the factor of the MS itself) to reduce the number of exception
TBF releases caused by N3105 overflow.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 1

Parameter Modifying
Version

None

2-230
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Detail

None

2.12 GPRS Other Parameters 2


2.12.1 NACC support (NACCSupport)
Full Name

NACC support

Abbreviation

NACCSupport

3GPP Name

NACC

3GPP Reference

3GPP TS44.060 V5.19.0


On the MS side, the Network Assisted Cell Change (NACC) function is a
part of GERAN feature package 1. When this function is supported,
1, the MS can receive system information needed for accessing the
target cell in packet transmission state.
2, the MS informs the network side about the cell change decision in
CCN mode.
Generally, NACC and CCN mode are used together.
At the network side, NACC means that:
1, the network sends the neighbor cell system information, which is used
by the MS for accessing to the target cell, on PACCH.
2, the network responds with the system information of the recommended
neighbor cell or another neighbor cell after receiving a cell change
notification from the MS.
The cooperation of NACC, CCN, and Packet (P)SI Status can shorten

Description

the time needed for completing a cell reselection process.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


It is recommended to enable the NACC function to shorten the interval
between cell reselections, relieve the influenced on packet services
being processed, and thus increase the packet service rate.

Change Mode

Offline

Related features

ZGO-02-02-010 Network-assisted Cell Change

2-231
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

[Cell]CCNActive
[Cell]SIStatusInd
[Cell]CCNSupport

Relationship

CCNActive, SIStatusInd, and CCNSupport must be enabled at the same


time.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.12.2 Net operation mode (NMO)


Full Name

Net operation mode

Abbreviation

NMO

3GPP Name

NMO

3GPP Reference

tocol"

TS44.060: "Radio Link Control/Medium Access Control (RLC/MAC) pro-

This parameter indicates which of the following three network operation


modes is used.
Network Operation Mode 1: The network sends a CS paging message to
the GPRS-attached MS through the same channel as the GPRS paging
channel (that is, packet paging channel or CCCH paging channel), or
through the GPRS service channel when a packet data channel has
been allocated to the MS. When this network operation mode is used,
the MS only needs to supervise one paging channel.
Network operation mode 1 shall be used when PBCCH is configured,
and Gs interface shall be configured when network operation mode 1
is used.
Network operation mode 2: The network sends a CS paging message to
the GPRS-attached MS through CCCH paging channel, which is also
used for GPRS paging. That means the MS only needs to supervise the
CCCH paging channel, through which the CS paging message is sent
Description

even a packet data channel has already been allocated to the MS.

2-232
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Network operation mode 3: The network sends a CS paging message


to the GPRS-attached MS through the CCCH paging channel, and
sends a GPRS paging message through a packet paging channel (if a
packet paging channel exists in the cell), or through the CCCH paging
channel too. That means the MS must supervise two paging channels
(if a packet paging channel exists in the cell) for receiving a CS paging
message or GPRS paging message.
Managed Object

BSC
Network operation mode 1, Network operation mode 2, Network operation

Value Range and Step

mode 3

Unit

None

Default Value

Network operation mode 2

Default Value

Select a network operation mode according to the configuration of

Configuration Reason

PBCCH, Gb interface, and Gs interface.


If PBCCH is configured at Gs interface, select Network operation mode
1. If neither Gs interface nor PBCCH exists in the network, select

Configuration Rule and

Network operation mode 2. If no Gs interface exists in the network, but

Adjustment Suggestion

PBCCH is configured, Network operation mode 3 can be selected. In


this network operation mode, the MS needs to listen the packet paging
channel and the CCCH paging channel.

Change Mode

Offline

Related features

ZGB-03-05-009 Network Mode of Operation (NMO) 1~3

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

YES

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-233
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.12.3 Page coordination support (PagCoordination)


Full Name

Page coordination support

Abbreviation

PagCoordination

3GPP Name

BSS_PAGING_COORDINATION
TS44.060: "Radio Link Control/Medium Access Control (RLC/MAC) pro-

3GPP Reference

tocol"
This parameter indicates whether the cells in the BSC support CS paging
coordination. As specified in the protocol 04.60.12.24, this parameter is
broadcasted in GPRS CELL OPTIONS through SI13, PSI1, and PSI13
messages. It is invalid when NMO is 1.
Paging coordination allows the network to send a CS paging message
through the PACCH used by PS services to the MS in PS transmission

Description

state.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

The default value depends on whether GPRS settings is supported.


Enable this function if CS paging needs to be processed by the MS
in PS transmission state. Take the possibility of PS service drop into

Configuration Rule and

account when enabling the function. Disable this function if the drop of

Adjustment Suggestion

PS service may occur due to CS paging processing. When this function


is disabled, CS paging will not be processed when the MS is in PS
transmission state.

Change Mode

Offline

Related features

ZGO-02-01-001 Paging Coordination

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None
2-234

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Detail

None

2.12.4 Satellite transmission at GB interface indication


(IsStatelliteGB)
Full Name

Satellite transmission at GB interface indication

Abbreviation

IsStatelliteGB

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the BSC supports transmission over

Description

satellite at Gb interface. This parameter is used for delay modification.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Generally, the default value is recommended. However, you can enable

Adjustment Suggestion

this function if necessary.

Change Mode

Offline

Related features

ZGO-05-01-003 Gb Interface over Satellite

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-235
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.12.5 Extended RLC send window allowed (IsWindowExpend)


Full Name

Extended RLC send window allowed

Abbreviation

IsWindowExpend

3GPP Name

None

3GPP Reference

tocol"

TS44.060: "Radio Link Control/Medium Access Control (RLC/MAC) pro-

This parameter indicates whether the RLC sliding window mechanism is


used. If this mechanism is adopted, the EDGE TBF is allowed to enlarge
Description

the size of the current RLC window in the step of 32.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The default value indicates that the window size is not enlarged in the

Configuration Reason

case of stagnating window.


Enable this function to enlarge the RLC window size to keep the RLC

Configuration Rule and


Adjustment Suggestion

data transmission if the stagnating window tolerance is required,


regarding that some factors such as radio quality impact the processing
of stagnating window for RLC transmission of TBF.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-236
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.12.6 TBF establish support (TBF_EST)


Full Name

TBF establish support

Abbreviation

TBF_EST

3GPP Name

TBF_EST
TS44.060: "Radio Link Control/Medium Access Control (RLC/MAC) pro-

3GPP Reference

tocol"
This parameter indicates whether the BSC supports the TBF
establishment process. In a TBF establishment process, the CTRL_ACK
field in the last Packet Control Acknowledgement message is used to
indicate whether it is needed to immediately establish a new uplink
TBF after an uplink TBF is released. In theory, enabling the TBF
establishment process can avoid the necessity that a resource request
is initiated for uplink TBF establishment once an uplink TBF is released,
which can improve the uplink throughput.
Some MSs that cannot support this function well (especially Blackberry
mobile phones and emulational mobile phones) may fail to access the
network due to improper TBF establishment process when this function

Description

is enabled in them.)

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The default value is set in consideration that some mobile phones do

Configuration Reason

not support this function.


When this function is enabled, the MS can find whether data transmission

Configuration Rule and


Adjustment Suggestion

is still needed from the last uplink block in the released uplink TBF. If
data transmission is needed, the MS can immediately re-establish an
uplink TBF. Enable or disable this function according to the support
capability of individual MSs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-237
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.12.7 Signal extended uplink TBF support (SIGNAL_EUTBF)


Full Name

Signal extended uplink TBF support

Abbreviation

SIGNAL_EUTBF

3GPP Name

None

3GPP Reference

tocol"

TS44.060: "Radio Link Control/Medium Access Control (RLC/MAC) pro-

This parameter indicates whether the extended uplink TBF is supported


for a signalling TBF. This switch is valid when the switch of extended uplink TBF is enabled. The signalling TBF refers to a TBF established for
Description

transmitting GMM signalling.

Managed Object

BSC

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value
Configuration Reason

The value of this switch is set according to the actual network situation.
And the MS must support the extended uplink TBF mode for enabling
this function.
Set this parameter according to the need of using the extended uplink

Configuration Rule and


Adjustment Suggestion

TBF with the consideration of the actual transmission status of signalling


TBF data because the signalling TBF process is generally completed in
a short time. It is recommended to enable this switch in a network that is
sensitive for the test of download rate performance.

Change Mode

Offline

Related features

ZGB-03-05-014 Delayed TBF Release in UL

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

2-238
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.12.8 Highest coding scheme of signal TBF (SigTBFMaxCode)


Full Name

Highest coding scheme of signal TBF

Abbreviation

SigTBFMaxCode

3GPP Name

None
TS44.060: "Radio Link Control/Medium Access Control (RLC/MAC) pro-

3GPP Reference

tocol"
This parameter limits the highest encoding mode of signallings in the case
of upper-layer signalling transmission, for example, the transmission of

Description

PDP activation and routing area update signallings.

Managed Object

BSC

Value Range and Step

MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7, MCS8, and MCS9

Unit

None

Default Value

MCS6

Default Value

The default value is set in consideration of signalling transmission

Configuration Reason

guarantee.
Determine the highest encoding mode for the signalling TBF according

Configuration Rule and


Adjustment Suggestion

to the radio quality in the network to ensure the stable transmission of


signalling data over the air interface. It is recommended to select MCS7,
MCS8, or MCS9 depending on the actual situation of the network that is
sensitive to the rate of higher-order encoding modes.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

0
2-239

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.12.9 Optimized POC service support (PocSupport)


Full Name

Optimized POC service support

Abbreviation

PocSupport

3GPP Name

None

3GPP Reference

None
This parameter indicates whether a POC user applies for a POC dedicated channel. If a mobile phone supports the Push to talk Over Cellular
(POS) function, it can be used as a two way radio. A user can talk to
another user or a group when the corresponding key is pressed on the

Description

mobile phone.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The default value depends on the actual requirement for POC service

Configuration Reason

in the network.

Configuration Rule and


Adjustment Suggestion

Set this parameter based on the requirement for POC service in the
network. If special processing is needed for POS service, set the other
functions relevant to POS service.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

0
2-240

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.12.10 Highest coding scheme of POC service in GPRS


(PocAttSelt_0)
Full Name

Highest coding scheme of POC service in GPRS

Abbreviation

PocAttSelt_0

3GPP Name

None

3GPP Reference

None
This parameter indicates the highest-order encoding mode that can be

Description

used for POC service by a GPRS-attached MS.

Managed Object

BSC

Value Range and Step

CS1, CS2, CS3, CS4

Unit

None

Default Value

CS3

Default Value

Set the default value on the condition that the stability of POS

Configuration Reason

transmission is ensured.

Configuration Rule and


Adjustment Suggestion

Set the highest order encoding mode according to the radio quality in
the network on the condition that the stability of POS transmission is
ensured.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]PocSupport

Relationship

This parameter is valid when the switch of POS service support is


enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-241
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.12.11 Highest coding scheme of POC service in EGPRS


(PocAttSelt_1)
Full Name

Highest coding scheme of POC service in EGPRS

Abbreviation

PocAttSelt_1

3GPP Name

None

3GPP Reference

None

Description

used for POC service by an EGPRS-attached MS.

Managed Object

BSC

Value Range and Step

MCS1..MCS9

Unit

None

Default Value

MCS6

Default Value

Set the default value on the condition that the stability of POS

Configuration Reason

transmission is ensured.

This parameter indicates the highest-order encoding mode that can be

Configuration Rule and


Adjustment Suggestion

Set the highest order encoding mode according to the radio quality in
the network on the condition that the stability of POS transmission is
ensured.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]PocSupport

Relationship

This parameter is valid when the switch of POS service support is


enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-242
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.12.12 Max users of POC service on shared PS channel0


(PSCAPATHS_UL)
Full Name

Max users of POC service on shared PS channel0

Abbreviation

PSCAPATHS_UL

3GPP Name

None

3GPP Reference

None
This parameter indicates the upper limit of users sharing uplink POC
service.
When POC dedicated channels are configured, this parameter indicates
the maximum number of POC users that can be accessed to the uplink
channel of each POC dedicated channel. No more POS users can
access the uplink channel of a POC dedicated channel once the number
of POC users accessing the downlink channel reaches the parameter

Description

value.

Managed Object

BSC
2..6

Value Range and Step

Step: 1

Unit

Count

Default Value

Default Value

Set the default value on the condition that the transmission rate is

Configuration Reason

ensured for POC users.

Configuration Rule and


Adjustment Suggestion

Set the maximum number of users sharing the POC dedicated channel
on the condition that the rate of POC transmission is ensured according
to the POC service feature in the network.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]PocSupport

Relationship

This parameter is valid when the switch of POS service support is


enabled.
2-243

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.12.13 Max users of POC service on shared PS channel1


(PSCAPATHS_DL)
Full Name

Max users of POC service on shared PS channel1

Abbreviation

PSCAPATHS_DL

3GPP Name

None

3GPP Reference

None
This parameter indicates the upper limit of users sharing downlink POC
service.
When POC dedicated channels are configured, this parameter indicates
the maximum number of POC users that can be accessed to the
downlink channel of each POC dedicated channel. No more POS users
can access the downlink channel of a POC dedicated channel once
the number of POC users accessing the downlink channel reaches the

Description

parameter value.

Managed Object

BSC
2..6

Value Range and Step

Step: 1

Unit

Count

Default Value

Default Value

Set the default value on the condition that the transmission rate is

Configuration Reason

ensured for POC users.

Configuration Rule and


Adjustment Suggestion
Change Mode

Set the maximum number of users sharing the POC dedicated channel
on the condition that the rate of POC transmission is ensured according
to the POC service feature in the network.
Offline

2-244
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related features

None

Related Parameters

[BSC]PocSupport

Relationship

This parameter is valid when the switch of POS service support is


enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.12.14 Service UTRAN CCO support (PSUTRANCCOSupp)


Full Name

Service UTRAN CCO support

Abbreviation

PSUTRANCCOSupp

3GPP Name

Internal

3GPP Reference

None
During PS handover or reselection, the SGSN can use the information
unit Service UTRAN CCO in a PS Handover Request message, a Create
BSS PFC message, or a DL UnitData PDU message to notify the BSC to
enable the 2G/3G reselection priority control or not, for example, prefer

Description

3G, not prefer 3G, and prohibit 3G for PS handover or reselection.

Managed Object

BSC

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

This parameter is not in use currently. CCOStrategy can also be used

Adjustment Suggestion

for 2G/3G priority control.

Change Mode

Offline

Related features

None
2-245

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

Relationship

[Cell]CCOStrategy
CCOStrategy, equivalent to this parameter, can also be used for 2G/3G
priority control.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.12.15 LLC Transfer Support (LLCTranSupport_0~LLCTranSuppo


rt_15)
Full Name

LLC Transfer Support

Abbreviation

LLCTranSupport_0~LLCTranSupport_15

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the BSC supports the transfer of
LLC frame. When the MS reselects a cell, the LLC frames cached in
the source cell need to be transferred to the target cell to ensure the
continuity of downlink data after the cell reselection. Set this parameter
depending on the value of SAPI. SAPI=1 indicates GMM signalling.
SAPI=3, 5, 9, or 11 indicates user data. Generally, the transfer of LLC
frame is enabled for user data, that is, in the case of SAPI=3, 5, 9, or 11.
The following describes the meaning of SAPI value, that is, the indicator
of service SAP.
Reserved 1 GPRS mobility management LLGMM
2 TOM2 TOM2
3 User data 3 LL3
4 Reserved 5 User data 5 LL3
6 Reserved -

Description

7 SMS LLSMS

2-246
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

8 TOM8 TOM8
9 User data 9 LL9
10 Reserved 11 User data 11 LL11
12 Reserved 13 Reserved 14 Reserved 15 Reserved Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


It is recommended to enable the transfer of user data frames in the case
of SAPI=3, 5, 9, or 11, and disable the transfer of GMM signalling frames

Configuration Rule and


Adjustment Suggestion

in the case of SAPI=1 because some protection mechanisms are used


for signalling frames, such as signalling timer and retransmission, and
signalling frames are not long. For the services indicated by the other
SAPI values, which are rarely used currently, disabling the transfer of
LLC frame is recommended.

Change Mode

Offline

Related features

ZGO-02-02-015 Enhanced Cell Reselection Procedure

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-247
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.12.16 LLC Pre-Transfer on NACC (Info_1_10)


Full Name

LLC Pre-Transfer on NACC

Abbreviation

Info_1_10

3GPP Name

None

3GPP Reference

None
This parameter indicates whether LLC frames can be transferred to the

Description

target cell in advance when an NACC process is initiated.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

It is recommended to enable this switch when the NACC function is

Adjustment Suggestion

enabled in the network.

Change Mode

Offline

Related features

ZGO-02-02-015 Enhanced Cell Reselection Procedure

Related Parameters

[BSC]LLCTranSupport_0~LLCTranSupport_15

Relationship

This parameter is valid when the transfer of LLC frame is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.12.17 PDU buffer time (Info_1_16)


Full Name

PDU buffer time

Abbreviation

Info_1_16

2-248
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

3GPP Name

None

3GPP Reference

None
This parameter indicates the longest time period during which the
BSSGP instance can be kept alive after the instance at the radio interface
is released. During a cell reselection, the old BSSGP instance can be
kept alive for some time. If the MS does not get access to a new cell
after the allowable alive time, the old BSSGP instance will be released.
The parameter value 0 indicates that the BSSGP instance will not be
cached. The parameter value 60000 indicates that the life time of
SGSN (PduLifeTime) is used as the time limit for keeping the instance
alive. The other parameter value indicates the smaller one between the

Description

configured value and the life time of SGSN (PduLifeTime) is used.

Managed Object

BSC
0..60000

Value Range and Step

Step: 1

Unit

10 ms

Default Value

500

Default Value

Set the default value in consideration of the time needed for cell

Configuration Reason

reselection and the time for TBF establishment of the MS.


Set the parameter value in consideration of the time needed for cell

Configuration Rule and


Adjustment Suggestion

reselection and the time for TBF establishment of the MS. If the cell
reselection can be completed in a short time and the DSP memory is
insufficient, decrease the parameter value appropriately.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-249
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.12.18 Choose PS route by NSVC (PSRouteByNSVC)


Full Name

Choose PS route by NSVC

Abbreviation

PSRouteByNSVC

3GPP Name

Internal

3GPP Reference

None
This parameter indicates that whether route selection over NSVC is
supported. This parameter is meaningful when multiple IPGB boards
are used on site.
If the BSC supports route selection over NSVC, an IPGB board can
independently detect the route status of its NSVC because the NS-ALIVE
message can only be sent through itself. In this case, the user plane
can select an NSVC in normal route status for service transmission. If
the BSC does not support route selection over NSVC, the NS-ALIVE
message is sent through another board instead of the IPGB board, and

Description

therefore the IPGB board cannot detect the route status of its NSVC.

Managed Object

BSC

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


Enable this function when the following conditions are met: load sharing

Configuration Rule and

is adopted at Gb interface; the BSC is configured with multiple IPGB

Adjustment Suggestion

boards, each connecting to a router or switch; and the SGSN has only
one remote destination IP address.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None
2-250

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Detail

None

2.12.19 Enable PS Uplink Power Control In Establishment Phase


(PSUlPwrCtlInEsta)
Full Name

Enable PS Uplink Power Control In Establishment Phase

Abbreviation

PSUlPwrCtlInEsta

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether the BSS writes the uplink power control
information in the IMMEDIATE ASSIGNMENT message after receiving a

Description

CHANNEL ACCESS REQUEST message from the MS.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value

The default value is set to 0 in consideration of the impact on the uplink

Configuration Reason

TBF establishment success rate.

Configuration Rule and


Adjustment Suggestion

Set the parameter value to 1 if the power control is needed for all
uplink data blocks during the TBF process when uplink power control
is required on site.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]UlPwCtrl

Relationship

This parameter is valid when the value of UlPwCtrl is 1.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->GPRS Other Parameters 2

Parameter Modifying
Version

None

2-251
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

2.13 BVC Flow Control Parameters


2.13.1 BVC flow control support (BVCFlowCtrl)
Full Name

BVC flow control support

Abbreviation

BVCFlowCtrl

3GPP Name

None

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


The BVC flow control is performed on the downlink at the Gb interface
between the SGSN and the BSS. It is the SGSN performing the flow
control based on the control parameters provided by the BSS, which
prevents the BSS from discarding some LLC data in the previous BVC
due to the timeout of the too busy packet channel (that is, too many
LLC frames are cached), and prevents the discard of new downlink LLC
data due to limited memory resources (that is, the cached LLC frames
overflow).
The BSSGP instance at the BSS side performs a periodic statistics on
current BVC leak rate (including long statistics and short statistics). If
the timer used for long statistics times out, a BVC Flow Control process
is initiated without condition. If the difference between two leak rates
exceeds CellFcThs, an acknowledgement from the SGSN is required
before the BVC Flow Control process is initiated. If the timer used for
short statistics times out and the difference between two leak rates
exceeds CellFcThs, a BVC Flow Control process is initiated after an

Description

acknowledgement is received from the SGSN.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value

The default value depends on the cell flow control function at the Gb

Configuration Reason

interface.

Configuration Rule and


Adjustment Suggestion
Change Mode

The cell flow control is enabled at the Gb interface by default. Enable


or disable the BVC flow control in consideration of the flow control
algorithm used in the core network.
Offline

2-252
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related features

ZGB-03-05-016 BVC Flow Control (in DL)

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->BVC Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.13.2 MS flow control support (MSFlowCtrl)


Full Name

MS flow control support

Abbreviation

MSFlowCtrl

3GPP Name

None

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


The MS flow control is performed on the downlink at the Gb interface
between the SGSN and the BSS. It is the SGSN performing the flow
control based on the control parameters provided by the BSS, which
prevents an MS in the BSS from discarding some LLC data due to the
timeout of the too busy packet channel (that is, too many LLC frames
are cached), and prevents the discard of new downlink LLC data due to
limited memory resources (that is, the cached LLC frames overflow).
The BSSGP process at the BSS side performs a periodic statistics on
the current leak rate of the MS. If the timer used for statistics times out,

Description

an MS Flow Control process is initiated without condition.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

Set the default value in consideration of the cell flow control granularity.

2-253
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and

Enable or disable the MS flow control in consideration of the cell flow

Adjustment Suggestion

control granularity and the MS flow control support in the CN.

Change Mode

Offline

Related features

ZGB-03-05-017 MS Flow Control (in DL)

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->BVC Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.13.3 Flow control mode (FlowCtrlMode)


Full Name

Flow control mode

Abbreviation

FlowCtrlMode

3GPP Name

None

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


The BSC can use one of the following three modes to report flow control
parameters to the SGSN.
Mode 1: In this mode, the BSC reports flow control parameters according
to the statistical traffic at the radio interface.
Mode 2: In this mode, the BSC reports flow control parameters according
to the maximum traffic supported by the cell.
Mode 3: In this mode, the BSC reports flow control parameters
according to the actual leak rate when the current CBL is large. If the
current CBL is small, the BSC reports flow control parameters according
to the maximum traffic supported by the cell.
When the parameter value is 1, that is, Mode 1 is selected, the
parameter FlowCtrlMode1Para is valid. When the parameter value is 2,

Description

that is, Mode 2 is selected, the parameter FlowCtrlMode2Para is valid.

Managed Object

BSC

2-254
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

1..3
Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Set the flow control parameters in consideration of the actual processing

Configuration Reason

capability at the radio interface of the cell.

Configuration Rule and

value. Select Mode 1 for ERICSSON SGSN. Select Mode 2 for

Adjustment Suggestion

HUWWEI equipment. And select Mode 3 when both ERICSSON and

Take the equipment actually used in the CN when setting the parameter

HUAWEI equipment are used.


Change Mode

Offline

Related features

ZGB-03-05-016 BVC Flow Control (in DL)

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->BVC Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.13.4 Parameter of Flow control mode 1 (FlowCtrlMode1Para)


Full Name

Parameter of Flow control mode 1

Abbreviation

FlowCtrlMode1Para

3GPP Name

None

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"

2-255
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

When the flow control mode 1 is used, the BSC reports flow control parameters according to the statistical traffic at the radio interface, which is
lower than the actual traffic due to retransmissions and TBF failures at
the radio interface. Therefore, the BSC reports flow control parameters
based on a product of the statistical traffic and the multiple specified by
Description

this parameter.

Managed Object

BSC
1..100

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Set the flow control mode 1 according to the network situation.


The parameter value depends on the flow control of the CN. If the actual

Configuration Rule and


Adjustment Suggestion

rate impacts the transmission of downlink data when the default value
is used, increase the parameter value in the case of uncontinuous
transmission or decrease the parameter value in the case of too fast
transmission.

Change Mode

Offline

Related features

ZGB-03-05-016 BVC Flow Control (in DL)

Related Parameters

[BSC]BVCFlowCtrl
[BSC]MSFlowCtrl
[BSC]PFCFlowCtrl

Relationship

This parameter is valid when the flow control switch is enabled.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->BVC Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.13.5 Parameter of Flow control mode 2 (FlowCtrlMode2Para)


Full Name

Parameter of Flow control mode 2


2-256

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Abbreviation

FlowCtrlMode2Para

3GPP Name

None

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


When the flow control mode 2 is selected, the BSC reports flow control parameters according to the maximum traffic supported by the cell, which is
calculated from the number of configured channels. The maximum traffic
of a cell equals to the product of the number of channels and the maximum traffic supported by each channel. This parameter indicates the

Description

maximum traffic supported by each channel. The traffic unit is 100 bps.

Managed Object

BSC
10..1000

Value Range and Step

Step: 1

Unit

100 bps

Default Value

214

Default Value

The default value is set according to the maximum theoretical rate of

Configuration Reason

single GPRS channel.


The parameter value depends on the flow control of the CN. If the actual

Configuration Rule and


Adjustment Suggestion

rate impacts the transmission of downlink data when the default value
is used, increase the parameter value in the case of uncontinuous
transmission or decrease the parameter value in the case of too fast
transmission.

Change Mode

Offline

Related features

ZGB-03-05-016 BVC Flow Control (in DL)

Related Parameters

[BSC]BVCFlowCtrl
[BSC]MSFlowCtrl
[BSC]PFCFlowCtrl

Relationship

This parameter is valid when the flow control switch is enabled.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->BVC Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-257
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.13.6 BVC flow control R MIN value (BVCFlowCtrlRMin)


Full Name

BVC flow control R MIN value

Abbreviation

BVCFlowCtrlRMin

3GPP Name

None

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


This parameter indicates the minimum value of leak rate (R), one of the
BVC flow control parameters reported to the SGSN. That is, the value of
reported parameter R must be equal to or larger than the value of this
parameter to prevent too slow transmission of SGSN downlink data due

Description

to too small leak rate. The unit of this parameter is 100 bps.

Managed Object

BSC
10..300

Value Range and Step

Step: 1

Unit

100 bps

Default Value

80

Default Value

The default value is set according to the minimum theoretical rate of

Configuration Reason

single GPRS channel.


The parameter value depends on the flow control of the CN. If the actual

Configuration Rule and


Adjustment Suggestion

rate impacts the transmission of downlink data when the default value
is used, increase the parameter value in the case of uncontinuous
transmission or decrease the parameter value in the case of too fast
transmission.

Change Mode

Offline

Related features

ZGB-03-05-016 BVC Flow Control (in DL)

Related Parameters

[BSC]BVCFlowCtrl
[BSC]MSFlowCtrl
[BSC]PFCFlowCtrl

Relationship

This parameter is valid when the flow control switch is enabled.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->BVC Flow Control

Parameter Modifying
Version

None

2-258
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Detail

None

2.13.7 MS flow control R MIN value (MSFlowCtrlRMin)


Full Name

MS flow control R MIN value

Abbreviation

MSFlowCtrlRMin

3GPP Name

None

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


This parameter indicates the minimum value of leak rate (R), one of the
MS flow control parameters reported to the SGSN. That is, the value of
reported parameter R must be equal to or larger than the value of this
parameter to prevent too slow transmission of SGSN downlink data due

Description

to too small leak rate. The unit of this parameter is 100 bps.

Managed Object

BSC
10..300

Value Range and Step

Step: 1

Unit

100 bps

Default Value

80

Default Value

The default value is set according to the minimum theoretical rate of

Configuration Reason

single GPRS channel.


The parameter value depends on the flow control of the CN. If the actual

Configuration Rule and


Adjustment Suggestion

rate impacts the transmission of downlink data when the default value
is used, increase the parameter value in the case of uncontinuous
transmission or decrease the parameter value in the case of too fast
transmission.

Change Mode

Offline

Related features

ZGB-03-05-017 MS Flow Control (in DL)

Related Parameters

[BSC]BVCFlowCtrl
[BSC]MSFlowCtrl
[BSC]PFCFlowCtrl

Relationship

This parameter is valid when the flow control switch is enabled.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-259
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->BVC Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.13.8 Support of PFC flow control procedures (PFCFlowCtrl)


Full Name

Support of PFC flow control procedures

Abbreviation

PFCFlowCtrl

3GPP Name

PFC-FC

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


The PFC flow control is performed on the downlink at the Gb interface
between the SGSN and the BSS. It is the SGSN performing the flow
control based on the control parameters provided by the BSS, which
prevents a PFC in the BSS from discarding some LLC data due to the
timeout of the too busy packet channel (that is, too many LLC frames
are cached), and prevents the discard of new downlink LLC data due to
limited memory resources (that is, the cached LLC frames overflow).
The BSSGP process at the BSS side performs a periodic statistics on
the current leak rate of the MS. If the timer used for statistics times out, a

Description

PFC Flow Control process is initiated without condition.

Managed Object

BSC
Yes, No

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value

The default value is set according to the function support status in the

Configuration Reason

CN and the PFC function support status.

Configuration Rule and


Adjustment Suggestion

To enable or disable the PFC flow control function, adjust the status
of this switch in consideration of the adjustment at the CN side at the
same time.

Change Mode

Offline

Related features

ZGB-03-05-017 MS Flow Control (in DL)

Related Parameters

None

Relationship

None

2-260
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

YES

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->BVC Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.13.9 Coefficient of BVC bucket size (Info_2_0)


Full Name

Coefficient of BVC bucket size

Abbreviation

Info_2_0

3GPP Name

None

3GPP Reference

None
This parameter is a coefficient used to calculate the size of the BVC leak
bucket. By changing the parameter value, that is, changing the size of
BVC leak bucket, the flow control offset can be adjusted.

Description

This parameter is supported in V6.20.21 and later versions.

Managed Object

BSC

Value Range and Step

10..20000

Unit

None

Default Value

3000

Default Value
Configuration Reason

The default value is set according to the default flow control period.
Set this parameter according to the flow control in the CN. If the default

Configuration Rule and


Adjustment Suggestion

parameter value impacts the transmission of downlink data, adjust the


parameter value according to the actual situation in the CN. If the bucket
size is too large, decrease the parameter value. If the bucket size is too
small, increase the parameter value.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]BVCFlowCtrl
[BSC]MSFlowCtrl
[BSC]PFCFlowCtrl
2-261

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

This parameter is valid when the flow control switch is enabled.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->BVC Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.13.10 Coefficient of MS bucket (Info_2_16)


Full Name

Coefficient of MS bucket

Abbreviation

Info_2_16

3GPP Name

None

3GPP Reference

None
This parameter is a coefficient used to calculate the size of the MS leak
bucket. By changing the parameter value, that is, changing the size of
MS leak bucket, the flow control offset can be adjusted.

Description

This parameter is supported in V6.20.21 and later versions.

Managed Object

BSC

Value Range and Step

10..20000

Unit

None

Default Value

300

Default Value
Configuration Reason

The default value is set according to the default flow control period.
Set this parameter according to the flow control in the CN. If the default

Configuration Rule and


Adjustment Suggestion

parameter value impacts the transmission of downlink data, adjust the


parameter value according to the actual situation in the CN. If the bucket
size is too large, decrease the parameter value. If the bucket size is too
small, increase the parameter value.

Change Mode

Offline

Related features

None

2-262
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related Parameters

[BSC]BVCFlowCtrl
[BSC]MSFlowCtrl
[BSC]PFCFlowCtrl

Relationship

This parameter is valid when the flow control switch is enabled.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->BVC Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.13.11 CBL in BVC/MS flow control (Info_1_9)


Full Name

CBL in BVC/MS flow control

Abbreviation

Info_1_9

3GPP Name

CBL

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


This parameter indicates whether Current Bucket Level (CBL) is reported
through a BVC/MS flow control message.

Description

This parameter is supported in V6.20.21 and later versions.

Managed Object

BSC
Yes, No

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

The default value is set according to the support status of the CN. If the
CN supports the report of CBL, enable this function to report the CBL
to the SGSN through a flow control message.

Configuration Rule and

Set this parameter depending on whether the CN supports the report of

Adjustment Suggestion

CBL during the flow control.

Change Mode

Offline

Related features

None

2-263
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

[BSC]BVCFlowCtrl
[BSC]MSFlowCtrl
[BSC]PFCFlowCtrl

Relationship

This parameter is valid when the flow control switch is enabled.

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->BVC Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.14 FUC Flow Control Map Parameters


2.14.1 Flow control reason (ChlReqRejBmp)
Full Name

Flow control reason

Abbreviation

ChlReqRejBmp

3GPP Name

None

3GPP Reference

None
This parameter indicates the FUC flow control level.
When the FUC flow control level is 0, the relevant parameters cannot

Description

be modified.

Managed Object

BSC

Value Range and Step

Level: 0..10

Unit

None

Default Value

0, 0, 0, 0, 0, 25, 25, 50, 75, 75, 75

Default Value
Configuration Reason

Set the FUC flow control level in consideration of the flow control type.

Configuration Rule and

Adjust the flow control policy by setting the percentages of different flow

Adjustment Suggestion

control levels based on the importance of different flow control reasons.

Change Mode

Offline

Related features

ZGB-03-04-001 BSC Load Control


2-264

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->FUC Flow Control Map

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.14.2 Emergency Call


Full Name

Emergency Call

Abbreviation

None

3GPP Name

None

3GPP Reference

None
This parameter indicates the percentage of the emergency calls
corresponding to an FUC flow control level.

Description

The value corresponding to level 0 cannot be modified.

Managed Object

BSC

Value Range and Step

Level: 0..10; value range: 0..100; step: 1

Unit

Default Value

[0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0]

Default Value

For this service type, emergency calls have the highest priority. Flow

Configuration Reason

control is not recommended whenever possible.


Generally, you do not have to modify this parameter and the default
value is recommended. When you set the parameter, you should set the
values of the 11 levels (level 0 to level 10) in ascending order. By doing

Configuration Rule and


Adjustment Suggestion

so, you can decide how fast this service type is put under flow control.
In the same level of all service types, you can know the proportion of
flow control for this service type as compared with that for other service
types. In each level, the higher the value is, the higher the proportion of
the service will be under flow control.

2-265
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGB-03-05-017 MS Flow Control

Related Parameters

[BSC]CPUFucFlc

Relationship

This parameter is valid only when the switch CPUFucFlc is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->FUC Flow Control Map->Emergency Call

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.14.3 Call Rebuilt


Full Name

Call Rebuilt

Abbreviation

None

3GPP Name

None

3GPP Reference

None
This parameter indicates the percentage of the re-established calls
corresponding to an FUC flow control level.

Description

The value corresponding to level 0 cannot be modified.

Managed Object

BSC

Value Range and Step

Level: 0..10; value range: 0..100; step: 1

Unit

Default Value

[0, 50, 75, 100, 100, 100, 100, 100, 100, 100, 100]

Default Value

For this service type, re-established calls have a relatively lower priority.

Configuration Reason

You can start flow control as early as possible.

2-266
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Generally, you do not have to modify this parameter and the default
value is recommended. When you set the parameter, you should set the
values of the 11 levels (level 0 to level 10) in ascending order. By doing
Configuration Rule and

so, you can decide how fast this service type is put under flow control.

Adjustment Suggestion

In the same level of all service types, you can know the proportion of
flow control for this service type as compared with that for other service
types. In each level, the higher the value is, the higher the proportion of
the service will be under flow control.

Change Mode

Offline

Related features

ZGB-03-05-017 MS Flow Control

Related Parameters

[BSC]CPUFucFlc

Relationship

This parameter is valid only when the switch CPUFucFlc is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->FUC Flow Control Map->Call Rebuilt

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.14.4 Call Response


Full Name

Call Response

Abbreviation

None

3GPP Name

None

3GPP Reference

None
This parameter indicates the percentage of the call responses
corresponding to an FUC flow control level.

Description

The value corresponding to level 0 cannot be modified.

Managed Object

BSC

Value Range and Step

Level: 0..10; value range: 0..100; step: 1

Unit

Default Value

[0, 0, 0, 0, 0, 25, 50, 50, 75, 75, 75]

2-267
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

For this service type, call responses generally must be ensured to


Default Value

succeed. However, if this service type is set to a high flow control level,

Configuration Reason

it should be under flow control. The service type has a relatively higher
priority, so you should put it under flow control as late as possible.
Generally, you do not have to modify this parameter and the default
value is recommended. When you set the parameter, you should set the
values of the 11 levels (level 0 to level 10) in ascending order. By doing

Configuration Rule and

so, you can decide how fast this service type is put under flow control.

Adjustment Suggestion

In the same level of all service types, you can know the proportion of
flow control for this service type as compared with that for other service
types. In each level, the higher the value is, the higher the proportion of
the service will be under flow control.

Change Mode

Offline

Related features

ZGB-03-05-017 MS Flow Control

Related Parameters

[BSC]CPUFucFlc

Relationship

This parameter is valid only when the switch CPUFucFlc is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->FUC Flow Control Map->Call Response

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.14.5 Calling
Full Name

Calling

Abbreviation

None

3GPP Name

None

3GPP Reference

None
This parameter indicates the percentage of the calling services
corresponding to an FUC flow control level.

Description

The value corresponding to level 0 cannot be modified.

Managed Object

BSC
2-268

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Value Range and Step

Level: 0..10; value range: 0..100; step: 1

Unit

Default Value

[0, 0, 0, 0, 25, 25, 40, 78, 100, 100, 100]


Similar to call responses, calling services generally must be ensured to

Default Value

succeed. However, if this service type is set to a high flow control level,

Configuration Reason

it should be under flow control. The service type has a relatively higher
priority, so you should put it under flow control as late as possible.
Generally, you do not have to modify this parameter and the default
value is recommended. When you set the parameter, you should set the
values of the 11 levels (level 0 to level 10) in ascending order. By doing

Configuration Rule and

so, you can decide how fast this service type is put under flow control.

Adjustment Suggestion

In the same level of all service types, you can know the proportion of
flow control for this service type as compared with that for other service
types. In each level, the higher the value is, the higher the proportion of
the service will be under flow control.

Change Mode

Offline

Related features

ZGB-03-05-017 MS Flow Control

Related Parameters

[BSC]CPUFucFlc

Relationship

This parameter is valid only when the switch CPUFucFlc is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->FUC Flow Control Map->Calling

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.14.6 Location Update


Full Name

Location Update

Abbreviation

None

3GPP Name

None

3GPP Reference

None

2-269
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the percentage of the location updates


corresponding to an FUC flow control level.
Description

The value corresponding to level 0 cannot be modified.

Managed Object

BSC

Value Range and Step

Level: 0..10; value range: 0..100; step: 1

Unit

Default Value

[0, 0, 0, 0, 0, 0, 0, 25, 25, 50, 75]

Default Value
Configuration Reason

For this service type, location update failures have the biggest effect on
the network. Therefore, location updates should have higher priority
than calling or called services and should be put under flow control later.
Generally, you do not have to modify this parameter and the default
value is recommended. When you set the parameter, you should set the
values of the 11 levels (level 0 to level 10) in ascending order. By doing

Configuration Rule and

so, you can decide how fast this service type is put under flow control.

Adjustment Suggestion

In the same level of all service types, you can know the proportion of
flow control for this service type as compared with that for other service
types. In each level, the higher the value is, the higher the proportion of
the service will be under flow control.

Change Mode

Offline

Related features

ZGB-03-05-017 MS Flow Control

Related Parameters

[BSC]CPUFucFlc

Relationship

This parameter is valid only when the switch CPUFucFlc is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->FUC Flow Control Map->Location Update

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.14.7 GPRS Access


Full Name

GPRS Access

Abbreviation

None
2-270

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

3GPP Name

None

3GPP Reference

None
This parameter indicates the percentage of the GPRS accesses
corresponding to an FUC flow control level.

Description

The value corresponding to level 0 cannot be modified.

Managed Object

BSC

Value Range and Step

Level: 0..10; value range: 0..100; step: 1

Unit

Default Value

[0, 0, 0, 20, 46, 73, 100, 100, 100, 100, 100]

Default Value
Configuration Reason

For this service type, location update failures have relatively smaller
effect on the network. Therefore, you can put this type of services under
flow control earlier.
Generally, you do not have to modify this parameter and the default
value is recommended. When you set the parameter, you should set the
values of the 11 levels (level 0 to level 10) in ascending order. By doing

Configuration Rule and

so, you can decide how fast this service type is put under flow control.

Adjustment Suggestion

In the same level of all service types, you can know the proportion of
flow control for this service type as compared with that for other service
types. In each level, the higher the value is, the higher the proportion of
the service will be under flow control.

Change Mode

Offline

Related features

ZGB-03-05-017 MS Flow Control

Related Parameters

[BSC]CPUFucFlc

Relationship

This parameter is valid only when the switch CPUFucFlc is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->FUC Flow Control Map->GPRS Access

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-271
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.14.8 Restore
Full Name

Restore

Abbreviation

None

3GPP Name

None

3GPP Reference

None
This parameter indicates the percentage of the reserved services
corresponding to an FUC flow control level.

Description

The value corresponding to level 0 cannot be modified.

Managed Object

BSC

Value Range and Step

Level: 0..10; value range: 0..100; step: 1

Unit

Default Value

[0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0]

Default Value
Configuration Reason

There are only a small number of reserved services in the current


network, so the proportion of flow control for these services is not set by
default. You can modify the value as needed.
Generally, you do not have to modify this parameter and the default
value is recommended. When you set the parameter, you should set the
values of the 11 levels (level 0 to level 10) in ascending order. By doing

Configuration Rule and

so, you can decide how fast this service type is put under flow control.

Adjustment Suggestion

In the same level of all service types, you can know the proportion of
flow control for this service type as compared with that for other service
types. In each level, the higher the value is, the higher the proportion of
the service will be under flow control.

Change Mode

Offline

Related features

ZGB-03-05-017 MS Flow Control

Related Parameters

[BSC]CPUFucFlc

Relationship

This parameter is valid only when the switch CPUFucFlc is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->FUC Flow Control Map->Restore

Parameter Modifying
Version

None

2-272
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Detail

None

2.14.9 Flow Control Map Slim Adjust


Full Name

Flow Control Map Slim Adjust

Abbreviation

None

3GPP Name

None

3GPP Reference

None
This parameter indicates a channel request rejection bitmap established
by the FUC. The bitmap is used to determine whether to reject an
access after flow control is started.
Each bit in the bitmap indicates whether to admit the access to a channel
for this reason. The value "1" means rejection and the value "0" means

Description

permission.

Managed Object

BSC

Value Range and Step

None

Unit

Digit

Default Value

None

Default Value

No default value is required. The only requirement is that the value you

Configuration Reason

set is in correct proportion to the entire rejection bitmap.

Configuration Rule and

The bitmap is generated according to the proportions you set. No

Adjustment Suggestion

adjustment is required.

Change Mode

Offline

Related features

ZGB-03-05-017 MS Flow Control

Related Parameters

[BSC]CPUFucFlc

Relationship

This parameter is valid only when the switch CPUFucFlc is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->FUC Flow Control Map->Flow Control Map


Slim Adjust

Parameter Modifying
Version

None
2-273

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

2.15 EDGE Parameters


2.15.1 PFC support (PFCSupport)
Full Name

PFC support

Abbreviation

PFCSupport

3GPP Name

PFC

3GPP Reference

TS48.018: "BSS GPRS Protocol (BSSGP)"


This parameter is broadcasted in GPRS Cell Options through SI13, PSI1
and PSI13 messages.
QoS in UMTS is introduced in the EGPRS system with bandwidth
characteristic. The negotiated QoS configuration can be transferred to
the BSS via Gb interface. The BSS can use the Packet Flow Context
(PFC) function to maintain the QoS subscription information, including
three signalling processes: QoS acquisition, QoS modification, and QoS
deletion.
The network informs the MS whether it supports the PFC process
through PFC_FEATURE_MODE in system information. If the network
supports the PFC process, the MS sends PFI through the PACKET
RESOURCE REQUEST message during uplink TBF establishment.
Then the BSS can determine the QoS required by the MS based on

Description

the received PFI.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The default value is set in consideration of the network service type

Configuration Reason

and the CN.

Configuration Rule and

To enable or disable the PFC function, adjust the status of this switch in

Adjustment Suggestion

consideration of the adjustment at the CN side at the same time.

Change Mode

Offline
ZGO-01-02-004 Streaming Service Policies
ZGO-01-02-003 Service based QoS

Related features

ZGB-01-02-001 Quality of Service (QoS)

2-274
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

YES

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.2 R99 Ind (R99Ind)


Full Name

R99 Ind

Abbreviation

R99Ind

3GPP Name

None

3GPP Reference

TS23.060: "Service description"


This parameter indicates R99.

The BSS determines whether to en-

code/decode information fields added after R99 according to this


parameter. Refer to the description of SI13 IN ts 44.018 for the encoding
Description

details.

Managed Object

BSC

Value Range and Step

R99, Not R99

Unit

None

Default Value

R99

Default Value
Configuration Reason

The CN and the MS are required to be of releases later than R99.

Configuration Rule and


Adjustment Suggestion

The CN and the MS are required to be of releases later than R99.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None
2-275

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

YES

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.3 Support of enhanced radio status procedures (EnRadioStu)


Full Name

Support of enhanced radio status procedures

Abbreviation

EnRadioStu

3GPP Name

Enhanced Radio Status feature

3GPP Reference

3GPP TS48.018 V8.6.0


This parameter indicates whether to support the negotiation of enhanced
Radio Status between the BSS and the SGSN. When the negotiation is
supported, at the BSS side:
1, the BSS sends a Radio Status message with the cause value of 0x03
when it is going to command the MS to perform a cell reselection in the
case that the transfer of internal LLC frames is not supported.
2, the BSS sends a Radio Status message with the cause value of 0x04
when it detects the failure of cell reselection command.
At the SGSN side:
1, Upon receiving the Radio Status message with the cause value of
0x03, the SGSN will:
a) resume downlink data to the target cell after the MS is updated in
the target cell.
b) or perform a process corresponding to the indicated cause after
receiving the Radio Status message with another cause value.
2, the SGSN resumes the transfer of downlink LLC frames which used
to be suspended after receiving a Radio Status message with the cause

Description

value of 0x04.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

2-276
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


When the negotiation of enhanced Radio Status with the SGSN is

Configuration Rule and


Adjustment Suggestion

enabled, downlink data can be suspended and resumed in time before


and after a cell reselection, which improves the network quality. It is
recommended to enable the negotiation function at the BSC side after
this function is enabled at the SGSN side.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]GBMsgSndInd_0
[BSC]GBMsgSndInd_1

Relationship

This functional switch is valid only when the RadioStatus send switch in
GBMsgSndInd is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

YES

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.4 RS (RS)
Full Name

RS

Abbreviation

RS

3GPP Name

Internal

3GPP Reference

None

2-277
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is the weight of uplink throughput at Gb interface. It is used


for dynamic Abis adjustment. During dynamic Abis resource allocation,
the resources are allocated by the quota that is the weight sum of several
items, including uplink throughput at Gb interface, downlink throughput at
Gb interface, the number of EGPRS MS access attempts, the number of
high bandwidth requests, the maximum bandwidth usage, GPRS carrier
rate, and EDGE carrier rate. All items are granted with a weight depending
on their importance. All the weights, RS, RR, RA, RM, RB, RG, and RE,
Description

fulfills the relation of RS+RR+RA+RM+RB+RG+RE=100.

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

Default Value

12

Default Value

Set this parameter according to the common traffic model, such as uplink

Configuration Reason

and downlink traffic, and the number of requests.


Generally, a sum of traffic weights (RS+RR+RA+RM+RB) lower than
50% is recommended. When the number of TBF link setup failures

Configuration Rule and


Adjustment Suggestion

caused by Abis channel congestion is not great, use the default value.
When the number of TBF link setup failures caused by Abis channel
congestion is great, you can appropriately decrease the parameter value
after making sure that enough Abis resources are available.

Change Mode

Offline

Related features

ZGO-03-03-001 Full Abis Dynamic Allocation

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-278
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.15.5 RR (RR)
Full Name

RR

Abbreviation

RR

3GPP Name

Internal

3GPP Reference

None
This parameter is the weight of downlink throughput at Gb interface. It is
used for dynamic Abis adjustment. During dynamic Abis resource allocation, the resources are allocated by the quota that is the weight sum of several items, including uplink throughput at Gb interface, downlink throughput at Gb interface, the number of EGPRS MS access attempts, the number of high bandwidth requests, the maximum bandwidth usage, GPRS
carrier rate, and EDGE carrier rate. All items are granted with a weight
depending on their importance. All the weights, RS, RR, RA, RM, RB,

Description

RG, and RE, fulfills the relation of RS+RR+RA+RM+RB+RG+RE=100.

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

Default Value

12

Default Value

Set this parameter according to the common traffic model, such as uplink

Configuration Reason

and downlink traffic, and the number of requests.


Generally, a sum of traffic weights (RS+RR+RA+RM+RB) lower than
50% is recommended. When the number of TBF link setup failures

Configuration Rule and


Adjustment Suggestion

caused by Abis channel congestion is not great, use the default value.
When the number of TBF link setup failures caused by Abis channel
congestion is great, you can appropriately decrease the parameter value
after making sure that enough Abis resources are available.

Change Mode

Offline

Related features

ZGO-03-03-001 Full Abis Dynamic Allocation

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property
2-279

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.6 RA (RA)
Full Name

RA

Abbreviation

RA

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the weight of the number of EGPRS MS access
attempts.

It is used for dynamic Abis adjustment.

During dynamic

Abis resource allocation, the resources are allocated by the quota that
is the weight sum of several items, including uplink throughput at Gb
interface, downlink throughput at Gb interface, the number of EGPRS
MS access attempts, the number of high bandwidth requests, the
maximum bandwidth usage, GPRS carrier rate, and EDGE carrier rate.
All items are granted with a weight depending on their importance. All
the weights, RS, RR, RA, RM, RB, RG, and RE, fulfills the relation of
Description

RS+RR+RA+RM+RB+RG+RE=100.

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

Default Value

Default Value

Set this parameter according to the common traffic model, such as uplink

Configuration Reason

and downlink traffic, and the number of requests.


Generally, a sum of traffic weights (RS+RR+RA+RM+RB) lower than
50% is recommended. When the number of TBF link setup failures

Configuration Rule and

caused by Abis channel congestion is not great, use the default value.

Adjustment Suggestion

When the number of TBF link setup failures caused by Abis channel
congestion is great, you can appropriately decrease the parameter value
after making sure that enough Abis resources are available.

Change Mode

Offline

Related features

ZGO-03-03-001 Full Abis Dynamic Allocation

Related Parameters

None

2-280
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.7 RM (RM)
Full Name

RM

Abbreviation

RM

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the weight of the number of high bandwidth
requests.

It is used for dynamic Abis adjustment.

During dynamic

Abis resource allocation, the resources are allocated by the quota that
is the weight sum of several items, including uplink throughput at Gb
interface, downlink throughput at Gb interface, the number of EGPRS
MS access attempts, the number of high bandwidth requests, the
maximum bandwidth usage, GPRS carrier rate, and EDGE carrier rate.
All items are granted with a weight depending on their importance. All
the weights, RS, RR, RA, RM, RB, RG, and RE, fulfills the relation of
Description

RS+RR+RA+RM+RB+RG+RE=100.

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

Default Value

14

Default Value

Set this parameter according to the common traffic model, such as uplink

Configuration Reason

and downlink traffic, and the number of requests.

2-281
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Generally, a sum of traffic weights (RS+RR+RA+RM+RB) lower than


50% is recommended. When the number of TBF link setup failures
Configuration Rule and
Adjustment Suggestion

caused by Abis channel congestion is not great, use the default value.
When the number of TBF link setup failures caused by Abis channel
congestion is great, you can appropriately decrease the parameter value
after making sure that enough Abis resources are available.

Change Mode

Offline

Related features

ZGO-03-03-001 Full Abis Dynamic Allocation

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.8 RB (RB)
Full Name

RB

Abbreviation

RB

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the weight of the amount of highest bandwidth. It is used for dynamic Abis adjustment. During dynamic Abis
resource allocation, the resources are allocated by the quota that is
the weight sum of several items, including uplink throughput at Gb
interface, downlink throughput at Gb interface, the number of EGPRS
MS access attempts, the number of high bandwidth requests, the
maximum bandwidth usage, GPRS carrier rate, and EDGE carrier rate.
All items are granted with a weight depending on their importance. All
the weights, RS, RR, RA, RM, RB, RG, and RE, fulfills the relation of

Description

RS+RR+RA+RM+RB+RG+RE=100.

2-282
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

Default Value

Default Value

Set this parameter according to the common traffic model, such as uplink

Configuration Reason

and downlink traffic, and the number of requests.


Generally, a sum of traffic weights (RS+RR+RA+RM+RB) lower than
50% is recommended. When the number of TBF link setup failures

Configuration Rule and

caused by Abis channel congestion is not great, use the default value.

Adjustment Suggestion

When the number of TBF link setup failures caused by Abis channel
congestion is great, you can appropriately decrease the parameter value
after making sure that enough Abis resources are available.

Change Mode

Offline

Related features

ZGO-03-03-001 Full Abis Dynamic Allocation

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.9 RG (RG)
Full Name

RG

Abbreviation

RG

3GPP Name

Internal

3GPP Reference

None

2-283
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the weight of GPRS carrier rate. It is used for
dynamic Abis adjustment. During dynamic Abis resource allocation, the
resources are allocated by the quota that is the weight sum of several
items, including uplink throughput at Gb interface, downlink throughput at
Gb interface, the number of EGPRS MS access attempts, the number of
high bandwidth requests, the maximum bandwidth usage, GPRS carrier
rate, and EDGE carrier rate. All items are granted with a weight depending
on their importance. All the weights, RS, RR, RA, RM, RB, RG, and RE,
Description

fulfills the relation of RS+RR+RA+RM+RB+RG+RE=100.

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

Default Value

15

Default Value

Set this parameter according to the common traffic model, such as uplink

Configuration Reason

and downlink traffic, and the number of requests.


Generally, a sum of carrier weights (RG+GE) lower than 50% is
recommended. The default value is recommended when the number of

Configuration Rule and


Adjustment Suggestion

TBF link setup failures caused by Abis channel congestion is not great.
When the number of TBF link setup failures caused by Abis channel
congestion is great, you can appropriately increase the parameter value
according to the actual number of configured GPRS carriers after making
sure that enough Abis resources are available.

Change Mode

Offline

Related features

ZGO-03-03-001 Full Abis Dynamic Allocation

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-284
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.15.10 RE (RE)
Full Name

RE

Abbreviation

RE

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the weight of EDGE carrier rate. It is used for
dynamic Abis adjustment. During dynamic Abis resource allocation, the
resources are allocated by the quota that is the weight sum of several
items, including uplink throughput at Gb interface, downlink throughput at
Gb interface, the number of EGPRS MS access attempts, the number of
high bandwidth requests, the maximum bandwidth usage, GPRS carrier
rate, and EDGE carrier rate. All items are granted with a weight depending
on their importance. All the weights, RS, RR, RA, RM, RB, RG, and RE,

Description

fulfills the relation of RS+RR+RA+RM+RB+RG+RE=100.

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

Default Value

35

Default Value

Set this parameter according to the common traffic model, such as uplink

Configuration Reason

and downlink traffic, and the number of requests.


Generally, a sum of carrier weights (RG+GE) lower than 50% is
recommended. The default value is recommended when the number of

Configuration Rule and


Adjustment Suggestion

TBF link setup failures caused by Abis channel congestion is not great.
When the number of TBF link setup failures caused by Abis channel
congestion is great, you can appropriately increase the parameter value
according to the actual number of configured EDGE carriers after making
sure that enough Abis resources are available.

Change Mode

Offline

Related features

ZGO-03-03-001 Full Abis Dynamic Allocation

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

2-285
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.11 ABIS resource dynamic manage (Info_1_8)


Full Name

ABIS resource dynamic manage

Abbreviation

Info_1_8

3GPP Name

None

3GPP Reference

None
This parameter decides whether to allow dynamic Abis resource
management.
If yes, Abis resources will be allocated to PS services according to the set
quota when being requested. In this case, each cell sharing the resource
pool will be allocated with a quota and the quotas add up to 100. The
quota is calculated according to several statistics, each of which is given
an importance-based weight. Such weights include RS, RR, RA, RM,
RB, RG, and RE. Such statistics include number of cell carriers, number
of packet accesses, uplink and downlink traffic of packet transmission,
and number of EGPRS MS requests. If these statistics change, the
quota will be re-calculated every five seconds and the database will

Description

allocate Abis timeslots to all cells for PS services according to the quota.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes
This parameter is a special functional switch. Enabling this switch will
allow inter-cell dynamic adjustments of Abis resources in the resource

Default Value
Configuration Reason

pool according to the current PS services and allocated PD channels, so


that the Abis resources can be allocated among the cells in an optimal
way.
If the switch is disabled, the Abis resources will be allocated with the
principle of "first come, first served" until they are all occupied.

2-286
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

If the Abis resources in a cell are enough to support the peak PS traffic
Configuration Rule and

in the cell, it is recommended to disable this switch to ensure that the

Adjustment Suggestion

Abis resources can be requested as many as possible for PS services


every time.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.12 FANR in uplink TBF support (Info_4_0)


Full Name

FANR in uplink TBF support

Abbreviation

Info_4_0

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether the uplink Fast Ack/Nack Reporting
(FANR) function is supported. If the network and the MS support the
function at the same time, the MS can carry the receiving information
of downlink radio blocks in uplink radio blocks. In this way, the network
can get the receiving situation of downlink radio blocks more quickly and
then speed up the retransmission of downlink radio blocks that were not

Description

correctly received. FANR is a function provided in EDGE evolution.

Managed Object

BSC

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

2-287
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

This function is not in commercial use in this version. The default value

Adjustment Suggestion

is recommended.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]INFO1_4_0

Relationship

The parameter INFO1_4_0 is valid only when this switch is enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.13 FANR in downlink TBF support (Info_4_1)


Full Name

FANR in downlink TBF support

Abbreviation

Info_4_1

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether the downlink Fast Ack/Nack Reporting
(FANR) function is supported. If the network and the MS support the function at the same time, the MS can carry the receiving information of uplink
radio blocks in downlink radio blocks. In this way, the network can get the
receiving situation of uplink radio blocks more quickly and then speed up
the retransmission of uplink radio blocks that were not correctly received.

Description

FANR is a function provided in EDGE evolution.

Managed Object

BSC

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

0
2-288

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

This function is not in commercial use in this version. The default value

Adjustment Suggestion

is recommended.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]INFO1_4_1

Relationship

The parameter INFO1_4_1 is valid only when this switch is enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.14 DLDC support (Info_4_2)


Full Name

DLDC support

Abbreviation

Info_4_2

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether the downlink dual-carrier function is
supported.
The downlink dual carrier function enables a terminal to receive the
carriers of two GERANs with different frequencies (or different MAIO
values in the case of frequency hopping). This function, allowing the
allocation of multiple timeslots to multiple carriers, can be regarded as
a natural extension of multi-slot technology. The downlink dual carrier

Description

function is a function provided in EDGE evolution.

Managed Object

BSC

Value Range and Step

0: No; 1: Yes

Unit

None

2-289
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

This function is not in commercial use in this version. The default value

Adjustment Suggestion

is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.15 RTTI support (Info_4_3)


Full Name

RTTI support

Abbreviation

Info_4_3

3GPP Name

Internal

3GPP Reference

None
This parameter indicates that the Reduced Transmission Time Interval
(RTTI) function is supported.
RTTI is relative to BTTI. Basic Transmission Time Interval (BTTI) allows
a radio block to be transmitted in four consecutive bursts on a channel,
that is, a radio block is transmitted in 20ms. RTTI allows a radio block
to be transmitted in two consecutive bursts on each of two channels
(PDCH-pair), that is, a radio block is transmitted in 10ms. RTTI is a

Description

function provided in EDGE evolution.

Managed Object

BSC

Value Range and Step

0: No; 1: Yes

2-290
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

This function is not in commercial use in this version. The default value

Adjustment Suggestion

is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.16 EGPRS2-A support (Info_4_4)


Full Name

EGPRS2-A support

Abbreviation

Info_4_4

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether EGPRS2-A is supported.
EGPRS2-A is the implementation of EGPRS2 in phase two. In this
phase, 16QAM, 32QAM, and Turbo code are used, QPSK and 1.2 times
the symbol rate are not used, and two new modulation coding modes,
DAS and UAS, are introduced. EGPRS2-A is a function provided in

Description

EDGE evolution.

Managed Object

BSC

Value Range and Step

0: No; 1: Yes

Unit

None
2-291

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

This function is not in commercial use in this version. The default value

Adjustment Suggestion

is recommended.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]EGPRS2AInitAttSelt_0
[Cell]EGPRS2AInitAttSelt_1
[Cell]EGPRS2AInitAttSelt_2
[Cell]EGPRS2AInitAttSelt_3
[Cell]InitAttachExch_2

Relationship

The parameter EGPRS2AInitAttSelt_0 is valid only when this switch


is enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.17 EGPRS prior to GPRS Support (Info_4_6)


Full Name

EGPRS prior to GPRS Support

Abbreviation

Info_4_6

3GPP Name

None

3GPP Reference

None
This parameter indicates whether EGPRS is prior to GPRS. If this
function is enabled, that is, EGPRS is prior to GPRS, the number
of blocks allocated to EGPRS and GPRS services will be adjusted
according to the weight of EGPRS when EGPRS and GPRS services
share the same channel.

Description

This parameter is supported in V6.20.614b and later versions.

2-292
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Managed Object

BSC
Yes, No

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


If this switch is enabled, the number of blocks allocated to EGPRS and

Configuration Rule and

GPRS services is adjusted according to the weight of EGPRS when

Adjustment Suggestion

EGPRS and GPRS services share the same channel. Enable or disable
this switch depending on the requirement on site.

Change Mode

Offline

Related features

None

Related Parameters

None
If this function is supported, the number of blocks allocated to EGPRS

Relationship

and GPRS services is adjusted according to the weight of EGPRS when


EGPRS and GPRS services share the same channel.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.15.18 Allocating weights of EGPRS (Info_4_7)


Full Name

Allocating weights of EGPRS

Abbreviation

Info_4_7

3GPP Name

Internal

3GPP Reference

None

2-293
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the weight for allocating blocks to EGPRS


services. When EGPRS is prior to GPRS, the BSC determines the
number of blocks allocated to EGPRS according to this weight.
When the parameter value is 0, no block will be allocated to EGPRS
services. When the parameter value is 100, no block will be allocated
Description

to GPRS services.

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

60

Default Value

The default value is set in consideration of the rate of EGPRS and

Configuration Reason

GPRS in the BSC.


If a channel is shared by EDGE and GPRS users, increasing the

Configuration Rule and


Adjustment Suggestion

parameter value results in more radio blocks allocated to EDGE users


and higher rate. Similarly, decreasing the parameter value results in less
radio blocks allocated to EDGE users and lower rate. This parameter is
effective on both dynamic and static data services.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]Info_4_6
[BSC]Info1_7_5
[BSC]Info1_7_6
This parameter is only valid when Info_4_6 is enabled. When Info_4_6

Relationship

and Info1_7_5 are enabled at the same time, Info1_7_6 takes effect
prior to this parameter.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EDGE Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-294
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.16 eMLPP Set Parameters


2.16.1 Strategy for preemption when assign (AssPreemptstrategy)
Full Name

Strategy for preemption when assign

Abbreviation

AssPreemptstrategy

3GPP Name

Internal

3GPP Reference

None
This parameter decides the preemption strategy in assignments when
there are no available channels. Its value corresponds to 15 levels of
priority (1 to 15), which are defined by the parameter Priority in the assign-

Description

ment command message or handover request message from the CN.

Managed Object

BSC
For the 15 levels of priority, the value range is Only forced handover, First

Value Range and Step

forced handover, if fail, forced release, and First forced release.

Unit

None

Default Value

Only forced handover

Default Value
Configuration Reason

Relatively, forced handovers have less effect on low-priority users.


Setting this parameter to "Only forced handover" has the least effect on
low-priority users. In this case, however, high-priority users are less
likely to access channels. If you set the parameter to "First forced

Configuration Rule and


Adjustment Suggestion

handover, if fail, forced release", high-priority users are more likely


to access channels, but will spend more time in accessing a channel
when a forced handover fails. If you set the parameter to "First forced
release", forced releases will be carried out if possible. In this case,
high-priority users are more likely to preempt channels, but low-priority
users will be affected more.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-295
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.2 Strategy for preemption when handover (HoPreemptstrategy)


Full Name

Strategy for preemption when handover

Abbreviation

HoPreemptstrategy

3GPP Name

Internal

3GPP Reference

None
This parameter decides the preemption strategy in handovers when there
are no available channels. Its value corresponds to 15 levels of priority
(1 to 15), which are defined by the parameter Priority in the assignment

Description

command message or handover request message from the CN.

Managed Object

BSC
For the 15 levels of priority, the value range is Only forced handover, First

Value Range and Step

forced handover, if fail, forced release, and First forced release.

Unit

None

Default Value

Only forced handover

Default Value
Configuration Reason

Relatively, forced handovers have less effect on low-priority users.


Setting this parameter to "Only forced handover" has the least effect on
low-priority users. In this case, however, high-priority users are less
likely to access channels. If you set the parameter to "First forced

Configuration Rule and


Adjustment Suggestion

handover, if fail, forced release", high-priority users are more likely


to access channels, but will spend more time in accessing a channel
when a forced handover fails. If you set the parameter to "First forced
release", forced releases will be carried out if possible. In this case,
high-priority users are more likely to preempt channels, but low-priority
users will be affected more.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

2-296
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.3 Max forced handover times when assign (AssForcedHoTry)


Full Name

Max forced handover times when assign

Abbreviation

AssForcedHoTry

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the maximum number of attempted forced
handovers when there are no available channels in the cell during an
assignment. After a forced handover is started, if one of the following
three events happens and the maximum number is not reached, more
forced handovers can be attempted:
(1) The user whose services are handed over forcedly fails to request
for channels in its adjacent cells.
(2) The forced handover fails.
(3) The user whose services are handed over forcedly fails to release

Description

the channel in ForceHoWait.

Managed Object

BSC
Priority: 1..15; Value range: 1.0.5

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Setting the default value to 1 increases the success rate of forced

Configuration Reason

handovers and affects fewer users.

Configuration Rule and

For high-priority users, more forced handovers can be attempted if you

Adjustment Suggestion

have not enabled the forced release function.

Change Mode

Offline

2-297
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.4 Max forced handover times when handover (HoForcedHoTry)


Full Name

Max forced handover times when handover

Abbreviation

HoForcedHoTry

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the maximum number of attempted forced
releases when there are no available channels in the cell during a
handover. After a forced handover is started, if one of the following three
events happens and the maximum number is not reached, more forced
handovers can be attempted:
(1) The user whose services are handed over forcedly fails to request
for channels in its adjacent cells.
(2) The forced handover fails.
(3) The user whose services are handed over forcedly fails to release

Description

the channel in ForceHoWait.

Managed Object

BSC
Priority: 1..15; Value range: 1.0.5

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Setting the default value to 1 increases the success rate of forced

Configuration Reason

handovers and affects fewer users.


2-298

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Configuration Rule and

For high-priority users, more forced handovers can be attempted if you

Adjustment Suggestion

have not enabled the forced release function.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.5 Max forced release times when assign (AssForcedRelTry)


Full Name

Max forced release times when assign

Abbreviation

AssForcedRelTry

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the maximum number of attempted forced releases when there are no available channels in the cell during an assignment. After a forced release is started, if the user fails to release the
channel in ForceRelWait and the maximum number is not reached, more

Description

forced releases can be attempted.

Managed Object

BSC
Priority: 1..15; Value range: 1.0.3

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Setting the default value to 1 increases the success rate of forced

Configuration Reason

handovers and affects fewer users.

2-299
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

For high-priority users, more attempted forced releases can be set.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.6 Max forced release times when handover (HoForcedRelTry)


Full Name

Max forced release times when handover

Abbreviation

HoForcedRelTry

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the maximum number of attempted forced releases when there are no available channels in the cell during a handover.
After a forced release is started, if the user fails to release the channel in
ForceRelWait and the maximum number is not reached, more forced re-

Description

leases can be attempted.

Managed Object

BSC
Priority: 1..15; Value range: 1.0.3

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Setting the default value to 1 increases the success rate of forced

Configuration Reason

handovers and affects fewer users.

2-300
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Configuration Rule and


Adjustment Suggestion

For high-priority users, more attempted forced releases can be set.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.7 Preemption duration when assign (AssPreempTimer)


Full Name

Preemption duration when assign

Abbreviation

AssPreempTimer

3GPP Name

Internal

3GPP Reference

None
This parameter decides the time period in which preemptions (forced
handovers or releases) can be initiated when there are no available
channels in the cell during an assignment. If the duration expires,
services must queue (The queuing period includes the preemption time)
and no more forced handovers or releases will be initiated.
Start: The assignment triggers a preemption, that is, attempted forced
handovers or releases begin.
Stop: A channel is accessed.

Description

At expiry: Forced handovers or releases will not be attempted any more.

Managed Object

BSC
Priority: 1..15; Value range: 25.0.130

Value Range and Step

Step: 1

Unit

100 ms

2-301
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

40

Default Value
Configuration Reason

Four seconds are enough for attempting multiple preemptions.

Configuration Rule and

For high-priority users, a higher value can be set to make it easier to

Adjustment Suggestion

access channels through preemption.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

[BSC]RmsT11
[BSC]AssPreempTimer
At the same priority, RmsT11 must be higher than AssPreempTimer.

Relationship

At the same priority, AssForceRelTimer must be lower than


AssPreempTimer.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.8 Preemption duration when handover (HoPreempTimer)


Full Name

Preemption duration when handover

Abbreviation

HoPreempTimer

3GPP Name

Internal

3GPP Reference

None
This parameter decides the time period in which preemptions (forced
handovers or releases) can be initiated when there are no available
channels in the cell during a handover. If the duration expires, services
must queue (The queuing period includes the preemption time) and no
more forced handovers or releases will be initiated.
Start: The handover triggers a preemption, that is, attempted forced
handovers or releases begin.
Stop: A channel is accessed.

Description

At expiry: Forced handovers or releases will not be attempted any more.


2-302

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Managed Object

BSC
Priority: 1..15; Value range: 25.0.130

Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value
Configuration Reason

Three seconds are enough for attempting multiple preemptions.

Configuration Rule and

For high-priority users, a higher value can be set to make it easier to

Adjustment Suggestion

access channels through preemption.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

[BSC]RmsTqho
[BSC]HoForceRelTimer
At the same priority, RmsTqho must be higher than HoPreempTimer.

Relationship

At the same priority, HoForceRelTimer must be lower than


HoPreempTimer.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.9 Timer for start forced release when assign


(AssForceRelTimer)
Full Name

Timer for start forced release when assign

Abbreviation

AssForceRelTimer

3GPP Name

Internal

3GPP Reference

None

2-303
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If there are no available channels in the cell during an assignment and


both forced handover and forced release are allowed, forced handovers
will be attempted first. If no channel is accessed, no more forced
handovers will be done after the timer expires. Instead, forced releases
will be attempted. This parameter decides when to attempt such forced
releases.
Start: A forced handover is initiated during the assignment.
Stop: A channel is accessed.
Description

At expiry: Forced releases will be attempted.

Managed Object

BSC
Priority: 1..15; Value range: 20..125

Value Range and Step

Step: 1

Unit

100 ms

Default Value

30

Default Value

The default value includes the time required to access a channel through

Configuration Reason

forced release.

Configuration Rule and

For high-priority users, you can set this parameter to a lower value for

Adjustment Suggestion

earlier forced releases if you have enabled the forced release function.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

[BSC]AssPreempTimer

Relationship

At the same priority, AssForceRelTimer must be lower than


AssPreempTimer.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-304
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.16.10 Timer for start forced release when handover


(HoForceRelTimer)
Full Name

Timer for start forced release when handover

Abbreviation

HoForceRelTimer

3GPP Name

Internal

3GPP Reference

None
If there are no available channels in the cell during a handover and both
forced handover and forced release are allowed, forced handovers
will be attempted first. If no channel is accessed, no more forced
handovers will be done after the timer expires. Instead, forced releases
will be attempted. This parameter decides when to attempt such forced
releases.
Start: A forced handover is initiated.
Stop: A channel is accessed.

Description

At expiry: Forced releases will be attempted.

Managed Object

BSC
Priority: 1..15; Value range: 20.0.125

Value Range and Step

Step: 1

Unit

100 ms

Default Value

25

Default Value

The default value includes the time required to access a channel through

Configuration Reason

forced release.

Configuration Rule and

For high-priority users, you can set this parameter to a lower value for

Adjustment Suggestion

earlier forced releases if you have enabled the forced release function.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

[BSC]HoPreempTimer

Relationship

At the same priority, HoForceRelTimer must be lower than


HoPreempTimer.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

2-305
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.11 Interval for search forced handover target when assign


(AssForceHoInterval)
Full Name

Interval for search forced handover target when assign

Abbreviation

AssForceHoInterval

3GPP Name

Internal

3GPP Reference

None
This parameter decides the waiting time before the next target search if
the forced handover target cannot be found and there are no available
channels in the cell during an assignment.
Start: No target is found after a forced handover is initiated during the
assignment.
Stop: Forced releases are attempted after the timer expires.

Description

At expiry: Another search for the forced handover target will be done.

Managed Object

BSC
Priority: 1..15; Value range: 5.0.20

Value Range and Step

Step: 1

Unit

100 ms

Default Value

Default Value

The default value makes it possible to access channels through multiple

Configuration Reason

attempted forced handovers with a reasonable frequency.

Configuration Rule and


Adjustment Suggestion

For high-priority users, a shorter interval can be set.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
2-306

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.12 Interval for search forced handover target when handover


(HoForceHoInterval)
Full Name

Interval for search forced handover target when handover

Abbreviation

HoForceHoInterval

3GPP Name

Internal

3GPP Reference

None
This parameter decides the waiting time before the next target search if
the forced handover target cannot be found and there are no available
channels in the cell during a handover.
Start: No target is found after a forced handover is initiated.
Stop: Forced releases are attempted after the timer expires.

Description

At expiry: Another search for the forced handover target will be done.

Managed Object

BSC
Priority: 1..15; Value range: 5.0.20

Value Range and Step

Step: 1

Unit

100 ms

Default Value

Default Value

The default value makes it possible to access channels through multiple

Configuration Reason

attempted forced handovers with a reasonable frequency.

Configuration Rule and


Adjustment Suggestion

For high-priority users, a shorter interval can be set.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

0
2-307

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.13 Interval for search forced release target when assign


(AssForceRelInterval)
Full Name

Interval for search forced release target when assign

Abbreviation

AssForceRelInterval

3GPP Name

Internal

3GPP Reference

None
This parameter decides the waiting time before the next target search
if the forced release target cannot be found and there are no available
channels in the cell during an assignment.
Start: No target is found after a forced release is initiated during the
assignment.
Stop: The timer for preemption expires.

Description

At expiry: Another search for the forced release target will be done.

Managed Object

BSC
Priority: 1..15; Value range: 5.0.20

Value Range and Step

Step: 1

Unit

100 ms

Default Value

Default Value

The default value makes it possible to access channels through multiple

Configuration Reason

attempted forced releases with a reasonable frequency.

Configuration Rule and


Adjustment Suggestion

For high-priority users, a shorter interval can be set.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

2-308
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.14 Interval for search forced release target when handover


(HoForceRelInterval)
Full Name

Interval for search forced release target when handover

Abbreviation

HoForceRelInterval

3GPP Name

Internal

3GPP Reference

None
This parameter decides the waiting time before the next target search
if the forced release target cannot be found and there are no available
channels in the cell during a handover.
Start: No target is found after a forced release is initiated during the
handover.
Stop: The timer for preemption expires.

Description

At expiry: Another search for the forced release target will be done.

Managed Object

BSC
Priority: 1..15; Value range: 5.0.20

Value Range and Step

Step: 1

Unit

100 ms

Default Value

Default Value

The default value makes it possible to access channels through multiple

Configuration Reason

attempted forced releases with a reasonable frequency.

Configuration Rule and


Adjustment Suggestion

For high-priority users, a shorter interval can be set.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

2-309
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.15 Queue timer for assign (RmsT11)


Full Name

Queue timer for assign

Abbreviation

RmsT11

3GPP Name

T11

3GPP Reference

48.008
This parameter decides the maximum time to wait in queue for resources
when there are no available channels in the cell during an assignment. If
no resource is obtained during the time period, the assignment fails.
Start: No channel is available for the assignment and the assignment
queues.
Stop: A channel is accessed.
At expiry: The channel allocation will fail and an assignment failure

Description

message will be sent to the MSC.

Managed Object

BSC
Priority: 1..15; Value range: 26..150

Value Range and Step

Step: 1

Unit

100 ms

Default Value

60

Default Value

The default value ensures that there is enough time for channel releases

Configuration Reason

and it will not be long before a channel allocation.

Configuration Rule and


Adjustment Suggestion

You can set this parameter to a reasonably higher value.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP
2-310

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related Parameters

[BSC]AssPreempTimer

Relationship

At the same priority, RmsT11 must be higher than AssPreempTimer.

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.16 Queue timer for handover (RmsTqho)


Full Name

Queue timer for handover

Abbreviation

RmsTqho

3GPP Name

Tqho

3GPP Reference

48.008
This parameter decides the maximum time to wait in queue for resources
when there are no available channels in the cell during a handover. If no
resource is obtained during the time period, the handover fails.
Start: No channel is available for the handover and the handover queues.
Stop: A channel is accessed.

Description

At expiry: The channel allocation and handover attempt will fail.

Managed Object

BSC
Priority: 1..15; Value range: 26..150

Value Range and Step

Step: 1

Unit

100 ms

Default Value

50

Default Value

The default value ensures that there is enough time for channel releases

Configuration Reason

and it will not be long before a channel allocation.

Configuration Rule and

The handover queuing time should not be too long because subsequent

Adjustment Suggestion

measurement reports can trigger new handover attempts.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP
2-311

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

[BSC]HoPreempTimer

Relationship

At the same priority, RmsTqho must be higher than HoPreempTimer.

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.17 Queue indicate when assign (QueueIndAss)


Full Name

Queue indicate when assign

Abbreviation

QueueIndAss

3GPP Name

Internal

3GPP Reference

None
This parameter decides whether to allow queuing during an assignment
or carry out the assignment according to the cell settings when there are

Description

no available channels in the cell.

Managed Object

BSC
Queue allowed when assign; Queue forbidden when assign; According

Value Range and Step

to the cell

Unit

None

Default Value

Queue forbidden when assign

Default Value

Generally, you do not have to enable the assignment queuing function

Configuration Reason

when there are enough network resources.

Configuration Rule and

When the traffic is high, enabling this function can relieve channel

Adjustment Suggestion

congestions but will increase the queuing time.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

[BSC]PreemptionIndAss
[BSC]ForcedHolndAss
[Cell]QueueInd_0
2-312

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

When either PreemptionIndAss or ForcedHolndAss is set to "allowed",


QueueIndAss must be set to "allowed".
Relationship

When either PreemptionIndAss or ForcedHolndAss is set to "According


to the cell", QueueIndAss must be set to "allowed" or "According to the
cell".

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.18 Queue allowed when handover (QueueIndHo)


Full Name

Queue allowed when handover

Abbreviation

QueueIndHo

3GPP Name

Internal

3GPP Reference

None
This parameter decides whether to allow queuing during a handover or
carry out the handover according to the cell settings when there are no

Description

available channels in the cell.

Managed Object

BSC

Value Range and Step

cording to the cell

Unit

None

Default Value

Queue forbidden when handover

Default Value

There are many target cells for handovers and the time interval between

Configuration Reason

handover attempts is short.

Queue allowed when handover, Queue forbidden when handover, Ac-

Configuration Rule and


Adjustment Suggestion

Enabling this function can relieve channel congestions in busy hours.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

2-313
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

[BSC]PreemptionIndHo
[BSC]ForcedHolndHo
[Cell]QueueInd_1
When either PreemptionIndHo or ForcedHolndHo is set to "allowed",

Relationship

QueueIndHo must be set to "allowed".


When either PreemptionIndHo or ForcedHolndHo is set to "allowed",
QueueIndHo must be set to "allowed" or "According to the cell".

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.19 Forced release indicate when assign (PreemptionIndAss)


Full Name

Forced release indicate when assign

Abbreviation

PreemptionIndAss

3GPP Name

Internal

3GPP Reference

None
This parameter decides whether to allow forced releases during an assignment or carry out the assignment according to the cell settings when

Description

there are no available channels in the cell.

Managed Object

BSC
Forced release allowed when assign, Forced release forbidden when as-

Value Range and Step

sign, According to the cell

Unit

None

Default Value

Forced release forbidden when assign

Default Value

Forced releases have more effect on low-priority users. By default, the

Configuration Reason

forced release function is disabled. You can enable it if necessary.

2-314
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

If you want high-priority users to access channels first during


Configuration Rule and

assignments, you should enable the forced release function. If the

Adjustment Suggestion

forced release function will be used by AssPreemptstrategy during the


assignment, you should enable this switch.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

[BSC]QueueIndAss
[Cell]PreemptionInd_0
When PreemptionIndAss is set to "allowed", QueueIndAss must be set

Relationship

to "allowed".
When PreemptionIndAss is set to "According to the cell", QueueIndAss
must be set to "allowed" or "According to the cell".

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.20 Forced release allowed when handover (PreemptionIndHo)


Full Name

Forced release allowed when handover

Abbreviation

PreemptionIndHo

3GPP Name

Internal

3GPP Reference

None
This parameter decides whether to allow forced releases during a handover or carry out the handover according to the cell settings when there

Description

are no available channels in the cell.

Managed Object

BSC
Forced release allowed when handover, Forced release forbidden when

Value Range and Step

handover, According to the cell

Unit

None

Default Value

Forced release forbidden when handover


2-315

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Forced releases have more effect on low-priority users. By default, the

Configuration Reason

forced release function is disabled. You can enable it if necessary.


If you want high-priority users to access channels first during handovers,

Configuration Rule and


Adjustment Suggestion

you should enable the forced release function. If the forced release
function will be used by HoPreemptstrategy during the handover, you
should enable this switch.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

[BSC]QueueIndHo
[Cell]PreemptionInd_1

Relationship

When PreemptionIndHo is set to "According to the cell", QueueIndHo


must be set to "allowed" or "According to the cell".

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.21 Forced handover indication for assign (ForcedHolndAss)


Full Name

Forced handover indication for assign

Abbreviation

ForcedHolndAss

3GPP Name

Internal

3GPP Reference

None
This parameter decides whether to allow forced handovers during an assignment or carry out the assignment according to the cell settings when

Description

there are no available channels in the cell.

Managed Object

BSC
Forced handover allowed when assign, Forced handover forbidden when

Value Range and Step

assign, According to the cell

Unit

None

Default Value

Forced handover forbidden when assign


2-316

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


If you want high-priority users to access channels through forced

Configuration Rule and

handover during assignments, you should enable this switch. If the

Adjustment Suggestion

forced handover function will be used by AssPreemptstrategy during the


assignment, you should enable this switch.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

[BSC]QueueIndAss
[Cell]ForcedHoInd_0

Relationship

When ForcedHolndAss is set to "According to the cell", QueueIndAss


must be set to "allowed" or "According to the cell".

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.22 Forced handover indication for handover (ForcedHolndHo)


Full Name

Forced handover indication for handover

Abbreviation

ForcedHolndHo

3GPP Name

Internal

3GPP Reference

None
This parameter decides whether to allow forced handovers during a handover or carry out the handover according to the cell settings when there

Description

are no available channels in the cell.

Managed Object

BSC
Forced handover allowed when handover, Forced handover forbidden

Value Range and Step

when handover, According to the cell

Unit

None

Default Value

Forced handover forbidden when handover


2-317

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


If you want high-priority users to access channels through forced

Configuration Rule and

handover during assignments, you should enable this switch. If the

Adjustment Suggestion

forced handover function will be used by HoPreemptstrategy during the


handover, you should enable this switch.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

[BSC]QueueIndHo
[Cell]ForcedHoInd_1

Relationship

When ForcedHolndHo is set to "According to the cell", QueueIndHo


must be set to "allowed" or "According to the cell".

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.23 Wait resource timer after forced release (ForceRelWait)


Full Name

Wait resource timer after forced release

Abbreviation

ForceRelWait

3GPP Name

Internal

3GPP Reference

None

2-318
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

This parameter decides the time to wait for resources after a forced
release. If a resource is obtained within this period, no more forced
releases will be initiated and the assignment will stop queuing. If not,
more forced releases will be initiated or the assignment will still queue
for resources, depending on parameter settings. The parameter should
be set according to the time required for a complete forced release.
Start: A forced release is initiated and the assignment waits for channel
releases.
Stop: The user that initiates the forced release accesses a channel.
At expiry: More forced releases will be initiated or the assignment will
Description

still queue for resources, depending on parameter settings.

Managed Object

BSC
10..40

Value Range and Step

Step: 1

Unit

100 ms

Default Value

25

Default Value

The default value is larger than the time required for a complete channel

Configuration Reason

release.

Configuration Rule and

This parameter should be set according to the time required for a

Adjustment Suggestion

complete channel release.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-319
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.16.24 Wait resource timer after forced handover (ForceHoWait,


100ms)
Full Name

Wait resource timer after forced handover (ForceHoWait, 100ms)

Abbreviation

ForceHoWait

3GPP Name

Internal

3GPP Reference

None
This parameter decides the time to wait for resources after a forced
handover. If a resource is obtained within this period, no more forced
handovers or releases will be initiated and the assignment will stop
queuing. If not, more forced handovers or releases will be initiated or
the assignment will still queue for resources, depending on parameter
settings. The parameter should be set according to the time required
for a complete handover.
Start: A forced handover is initiated and the assignment waits for
channel releases.
Stop: The user that initiates the forced release accesses a channel.
At expiry: More forced handovers or releases will be initiated or the
assignment will still queue for resources, depending on parameter

Description

settings.

Managed Object

BSC
10..40

Value Range and Step

Step: 1

Unit

100 ms

Default Value

25

Default Value

The default value is larger than the time required for a complete

Configuration Reason

handover.

Configuration Rule and

This parameter should be set according to the time required for a

Adjustment Suggestion

complete handover and channel release.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-320
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.25 Enough low priority for preemption (LowestPriority)


Full Name

Enough low priority for preemption

Abbreviation

LowestPriority

3GPP Name

Internal

3GPP Reference

None
During searches for the targets of forced handovers or releases, if the priorities of the targets are not higher than this priority, these targets will be
considered to have the lowest priorities and can be the targets of forced
handovers or releases. No more searches will be done. In this way, the
number of times of searches is reduced. The value "1" indicates the high-

Description

est priority.

Managed Object

BSC
1..15

Value Range and Step

Step: 1

Unit

None

Default Value

14

Default Value
Configuration Reason

By default, the user who has the lowest priority is found.

Configuration Rule and

This parameter should be set according to the actual lowest priority

Adjustment Suggestion

and the expected lowest priority.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
2-321

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.26 Enough call duration for preemption (LongCallDuration)


Full Name

Enough call duration for preemption

Abbreviation

LongCallDuration

3GPP Name

Internal

3GPP Reference

None
During searches for the targets of forced handovers or releases, if the call
duration of the targets is larger than this parameter, these targets will be
considered to have enough long calls and can be the targets of forced
handovers or releases. No more searches for the target with the longest
call duration will be done. In this way, the number of times of searches is

Description

reduced.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1
Measurement report period (converted to multiple common measurement

Unit

report periods in pre-processing)

Default Value

50

Default Value

This is a special function. The default value is set according to your

Configuration Reason

specific needs.

Configuration Rule and

You can set this parameter to a higher value to ensure that the users

Adjustment Suggestion

with short calls will not be the targets of forced releases.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

2-322
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.27 Forced handover target penalty time (ForceHoPenalty)


Full Name

Forced handover target penalty time

Abbreviation

ForceHoPenalty

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the time period in which the target of forced
handover cannot be a target any more after the forced handover fails.
Start: The target fails to carry out the handover and release the channel.
Stop: None.

Description

At expiry: The target can be a target of forced handover again.

Managed Object

BSC
0..255

Value Range and Step

Step: 1
Measurement report period (converted to multiple common measurement

Unit

report periods in pre-processing)

Default Value

60

Default Value

The default penalty time is set to avoid failures caused by repeated

Configuration Reason

forced handovers of the same user.

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio signal changes of


the user that is handed over forcedly. When the user moves quickly,
you can set a shorter penalty time.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

2-323
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.16.28 Priority of emergency service (EmergServicelPrio)


Full Name

Priority of emergency service

Abbreviation

EmergServicelPrio

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the priority of emergency calls. Those calls
whose priorities are higher than the parameter are emergency calls. The

Description

value "1" indicates the highest priority.

Managed Object

BSC
1..15

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Generally, the priority of emergency calls is 1.

Configuration Rule and

This parameter should be set according to the priority of your local

Adjustment Suggestion

emergency calls.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes

2-324
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->EMLPP Set

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.17 User Access Flow Control Parameters


2.17.1 Access class parameter config select (AccConfigSelect)
Full Name

Access class parameter config select

Abbreviation

AccConfigSelect

3GPP Name

None

3GPP Reference

None
This parameter is a user access control switch based on the priority of
SIM cards.
Through the NMS, you can totally configure four sets of access
parameters. This parameter decides whether to enable the user access
control based on the priority of SIM cards and which set of parameters
are used.
0: Disable the user access control function.
1: Enable the first ACC configuration data as user access control
parameters.
2: Enable the second ACC configuration data as user access control
parameters.
3: Enable the third ACC configuration data as user access control
parameters.
4: Enable the fourth ACC configuration data as user access control

Description

parameters.

Managed Object

BSC
0: Disable the user access control function.
1: Enable the first ACC configuration data as user access control
parameters.
2: Enable the second ACC configuration data as user access control
parameters.
3: Enable the third ACC configuration data as user access control
parameters.
4: Enable the fourth ACC configuration data as user access control

Value Range and Step

parameters.
2-325

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

This parameter can be enabled upon request.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->User Access Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.17.2 First barred class 0 ~ First barred class 3


(FirstBarredClass_0~FirstBarredClass_3)
Full Name

First barred class 0 ~ First barred class 3

Abbreviation

FirstBarredClass_0~FirstBarredClass_3

3GPP Name

None

3GPP Reference

None
This parameter indicates the starting priority of the SIM cards that are
rejected to access the system. Starting from this priority, the SIM cards
in the window size BarredClassWindows will be rejected to access the
system.

Description

For details, refer to the description of BarredClassWindows.

Managed Object

BSC
0..9

Value Range and Step

Step: 1
2-326

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Unit

None

Default Value

Default Value
Configuration Reason

The value "0" is the starting value.

Configuration Rule and

You can set this parameter according to the priority of SIM cards to be

Adjustment Suggestion

rejected.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->User Access Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.17.3 Barred class windows 0 ~ Barred class windows 3


(BarredClassWindows_0~BarredClassWindows_3)
Full Name

Barred class windows 0 ~ Barred class windows 3

Abbreviation

BarredClassWindows_0~BarredClassWindows_3

3GPP Name

None

3GPP Reference

None

2-327
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the priority window size of SIM cards under
flow control.
For the SIM cards of priority 0 to 10, selective flow control is carried
out. Starting from the SIM priority FirstBarredClass, the SIM cards
in the window size BarredClassWindows within the time period
BarredTimeStep will be rejected to access the system. This process will
repeat after the time period expires.
For example, if you set FirstBarredClass, BarredTimeStep, and
BarredClassWindows to 1, 30, and 3 respectively, the SIM cards of
priority 1, 2, and 3 will be rejected to access the system at first. After 30
seconds, the SIM cards of priority 2, 3, and 4 will be rejected but the SIM
cards of priority 1 will be allowed. After another 30 seconds, the SIM
Description

cards of priority 3, 4, and 5 will be rejected, and so on.

Managed Object

BSC
1..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default value ensures that the MSs of one priority is barred at a time.

Configuration Rule and

The higher the value is, the more MSs will be barred at the same time.

Adjustment Suggestion

You can set this parameter as needed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->User Access Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-328
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.17.4 Barred time step 0 ~ Barred time step 3 (BarredTimeStep_


0~BarredTimeStep_3)
Full Name

Barred time step 0 ~ Barred time step 3

Abbreviation

BarredTimeStep_0~BarredTimeStep_3

3GPP Name

None

3GPP Reference

None
This parameter indicates the sliding speed of the window in which
accesses are rejected. The users of different priorities in a window size
within each time period will be rejected to access the system. After the
time period expires, the window slides.

Description

For details, refer to the description of BarredClassWindows.

Managed Object

BSC
1..3600

Value Range and Step

Step: 1

Unit

Default Value

30

Default Value
Configuration Reason

The MSs are rejected in turn once every 30 seconds.

Configuration Rule and

The higher the value is, the longer the rejection will last. You should set

Adjustment Suggestion

this parameter according to user satisfaction.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->User Access Flow Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-329
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.17.5 Access Control (AccessControl)


Full Name

Access Control

Abbreviation

AccessControl

3GPP Name

Access Control Class


C CN, Access Control Class N (octet 3(except bit 3) and octet 4) For a
mobile station with AC C = N access is not barred if the AC CN bit is coded

3GPP Reference

with a "0"; N = 0, 1, .. 9, 11, .., 15.


This parameter decides which priority of MSs are allowed to access
the local BSC. MSs have 15 levels of priorities, which can be set
respectively. According to the protocol, Priority 10 is for special purpose
only and cannot be used for flow control.
Cn represents the MSs of priority n (n=0, 1, ..., 9, 11, ..., 15).
When Cn is 0, the MSs of priority n are allowed to access the cell.
When Cn is 1, the MSs of priority n are not allowed to access the cell.
This parameter is valid when the parameter UseCellAcc is 0. Otherwise,

Description

the cell-level parameter AccessControl will be used.

Managed Object

BSC
0..9, 11..15

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Generally, all MSs are allowed to access the cell.

Configuration Rule and

If you want the MSs of a priority to access the cell, you should set Cn to

Adjustment Suggestion

0. If not, you should set Cn to 1.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->User Access Flow Control

Parameter Modifying
Version

None
2-330

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Detail

None

2.18 UPPB Resource Alarm Parameters


2.18.1 Enable UPPB resource alarm (UppbResAlarmEnable)
Full Name

Enable UPPB resource alarm

Abbreviation

UppbResAlarmEnable

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether the resource alerting function of UPPB
is enabled. The resource availability of UPPB is measured by the
availability of each DSP resource on the UPPB board. The measurement
indexes include the memory application failure rate of DSP, the utilization
ratio of the MAC instance and the BSSGP instance, the utilization ratio of
the mac-tlli index table and the bssgp-tlli index table, and the utilization

Description

ratio of the channel instance and the TS instance.

Managed Object

BSC

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Default Value

This function is enabled by default for supervising the usage of UPPB

Configuration Reason

DSP resources.

Configuration Rule and


Adjustment Suggestion

Set the parameter value to 0 when the UPPB resource alerting function
is not needed. Set the parameter value to 1 when the UPPB resource
alerting function is needed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

2-331
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->UPPB Resource Alarm

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.18.2 Alarm threshold of failure ratio for allocating memory


(UppbResAlarmThs_0)
Full Name

Alarm threshold of failure ratio for allocating memory

Abbreviation

UppbResAlarmThs_0

3GPP Name

Internal

3GPP Reference

None
This parameter is an alarm threshold of memory application failure rate of
UPPB DSP. When the memory application failure rate is higher than this

Description

threshold, a threshold crossing alarm is reported.

Managed Object

BSC
1..100

Value Range and Step

Step: 1

Unit

Default Value

15

Default Value

The default value is set for effectively monitoring the memory application

Configuration Reason

failure rate of the UPPB DSP.


If the parameter value is small, you can effectively monitor the memory

Configuration Rule and


Adjustment Suggestion

application failure rate. However, frequent switching between alarm


reporting and alarm clearing may occur due to the high sensitivity. If the
parameter value is large, an alarm is reported only when the memory
application rate is very high.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]UppbResAlarmEnable
[BSC]OverThsDuration
This parameter is valid only when the UppbResAlarmEnable switch is

Relationship

enabled. This parameter, together with OverThsDuration, determines


the conditions for reporting and clearing a threshold crossing alarm.

Related Interfaces

None

2-332
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->UPPB Resource Alarm

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.18.3 Alarm threshold of use ratio for mac instance


(UppbResAlarmThs_1)
Full Name

Alarm threshold of use ratio for mac instance

Abbreviation

UppbResAlarmThs_1

3GPP Name

Internal

3GPP Reference

None
This parameter is an alarm threshold of MAC instance utilization. When
the MAC instance utilization is higher than this threshold, a threshold
crossing alarm is reported.

Description
Managed Object

BSC
30..100

Value Range and Step

Step: 1

Unit

Default Value

90

Default Value

The default value is set for effectively monitoring the MAC instance

Configuration Reason

utilization.
When the parameter value is small, a threshold crossing alarm will be

Configuration Rule and


Adjustment Suggestion

reported when the MAC instance utilization is not high. If the parameter
value is large, a threshold crossing alarm will be reported only when the
MAC instance utilization is very high. A value equal to or larger than 60
is recommended to prevent frequent alarm reporting.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]UppbResAlarmEnable
[BSC]OverThsDuration
2-333

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is valid only when the UppbResAlarmEnable switch is


Relationship

enabled. This parameter, together with OverThsDuration, determines


the conditions for reporting and clearing a threshold crossing alarm.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->UPPB Resource Alarm

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.18.4 Alarm threshold of use ratio for bssgp instance and tlli index
(UppbResAlarmThs_2)
Full Name

Alarm threshold of use ratio for bssgp instance and tlli index

Abbreviation

UppbResAlarmThs_2

3GPP Name

Internal

3GPP Reference

None
This parameter is an alarm threshold of BSSGP instance and index
table utilization. When the BSSGP instance and index table utilization is
higher than this threshold, a threshold crossing alarm is reported.

Description
Managed Object

BSC
30..100

Value Range and Step

Step: 1

Unit

Default Value

90

Default Value

The default value is set for effectively monitoring the BSSGP instance

Configuration Reason

utilization.
When the parameter value is small, a threshold crossing alarm will

Configuration Rule and


Adjustment Suggestion

be reported when the BSSGP instance utilization is not high. If the


parameter value is large, a threshold crossing alarm will be reported only
when the BSSGP instance utilization is very high. A value equal to or
larger than 60 is recommended to prevent frequent alarm reporting.

2-334
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Change Mode

Offline

Related features

None

Related Parameters

[BSC]UppbResAlarmEnable
[BSC]OverThsDuration
This parameter is valid only when the UppbResAlarmEnable switch is

Relationship

enabled. This parameter, together with OverThsDuration, determines


the conditions for reporting and clearing a threshold crossing alarm.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->UPPB Resource Alarm

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.18.5 Alarm threshold of use ratio for mac-tlli index


(UppbResAlarmThs_3)
Full Name

Alarm threshold of use ratio for mac-tlli index

Abbreviation

UppbResAlarmThs_3

3GPP Name

Internal

3GPP Reference

None
This parameter is an alarm threshold of MAC-tlli index table utilization.
When the mac-tlli index table utilization is higher than this threshold, a
threshold crossing alarm is reported.

Description
Managed Object

BSC
30..100

Value Range and Step

Step: 1

Unit

Default Value

90

Default Value

The default value is set for effectively monitoring the MAC-tlli index

Configuration Reason

table utilization.

2-335
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

When the parameter value is small, a threshold crossing alarm will


Configuration Rule and
Adjustment Suggestion

be reported when the MAC-tlli index table utilization is not high. If the
parameter value is large, a threshold crossing alarm will be reported only
when the MAC-tlli index table utilization is very high. A value equal to or
larger than 60 is recommended to prevent frequent alarm reporting.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]UppbResAlarmEnable
[BSC]OverThsDuration
This parameter is valid only when the UppbResAlarmEnable switch is

Relationship

enabled. This parameter, together with OverThsDuration, determines


the conditions for reporting and clearing a threshold crossing alarm.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->UPPB Resource Alarm

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.18.6 Alarm threshold of use ratio for radio channel instance


(UppbResAlarmThs_4)
Full Name

Alarm threshold of use ratio for radio channel instance

Abbreviation

UppbResAlarmThs_4

3GPP Name

Internal

3GPP Reference

None
This parameter is an alarm threshold of channel instance utilization.
When the channel instance utilization is higher than this threshold, a
threshold crossing alarm is reported.

Description
Managed Object

BSC
30..100

Value Range and Step

Step: 1

2-336
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Unit

Default Value

90

Default Value

The default value is set for effectively monitoring the channel instance

Configuration Reason

utilization.
When the parameter value is small, a threshold crossing alarm will

Configuration Rule and


Adjustment Suggestion

be reported when the channel instance utilization is not high. If the


parameter value is large, a threshold crossing alarm will be reported only
when the channel instance utilization is very high. A value equal to or
larger than 60 is recommended to prevent frequent alarm reporting.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]UppbResAlarmEnable
[BSC]OverThsDuration
This parameter is valid only when the UppbResAlarmEnable switch is

Relationship

enabled. This parameter, together with OverThsDuration, determines


the conditions for reporting and clearing a threshold crossing alarm.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->UPPB Resource Alarm

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.18.7 Alarm threshold of use ratio for TS instance


(UppbResAlarmThs_5)
Full Name

Alarm threshold of use ratio for TS instance

Abbreviation

UppbResAlarmThs_5

3GPP Name

Internal

3GPP Reference

None

2-337
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is an alarm threshold of TS instance utilization. When


the TS instance utilization is higher than this threshold, a threshold
crossing alarm is reported. In the case of E1 Abis networking, the
number of TS instances equals the number of 16 Kbps. In the case of IP
Abis networking, TS instance is equivalent to channel instance.
Description
Managed Object

BSC
30..100

Value Range and Step

Step: 1

Unit

Default Value

95

Default Value

The default value is set for effectively monitoring the TS instance

Configuration Reason

utilization.
When the parameter value is small, a threshold crossing alarm will be

Configuration Rule and


Adjustment Suggestion

reported when the TS instance utilization is not high. If the parameter


value is large, a threshold crossing alarm will be reported only when the
TS instance utilization is very high. A value equal to or larger than 60 is
recommended to prevent frequent alarm reporting.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]UppbResAlarmEnable
[BSC]OverThsDuration
This parameter is valid only when the UppbResAlarmEnable switch is

Relationship

enabled. This parameter, together with OverThsDuration, determines


the conditions for reporting and clearing a threshold crossing alarm.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->UPPB Resource Alarm

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-338
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.18.8 Duration of exceeding alarm threshold (OverThsDuration)


Full Name

Duration of exceeding alarm threshold

Abbreviation

OverThsDuration

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the duration of threshold crossing alarms of
indexes relevant to UPPB resources, including memory application
failure rate, MAC instance utilization, BSSGP instance and index table
utilization, mac-tlli index table utilization, channel instance utilization,
and TS instance utilization. It is used for jitter-prevention processing. On
one hand, a threshold crossing alarm is reported only when the duration
of an index value that exceeds the preset threshold range, reaches the
value of this parameter. On the other hand, the threshold crossing
alarm is cleared only when the duration that the index value is within the

Description

threshold range reaches the value of this parameter.

Managed Object

BSC
60..7200

Value Range and Step

Step: 1

Unit

Default Value

600

Default Value
Configuration Reason

This parameter is used to prevent the jitter of alarm reporting.


If the parameter value is small, threshold crossing alarms will be reported

Configuration Rule and


Adjustment Suggestion

in the case of a burst of resource utilization. If the parameter value is


large, threshold crossing alarms will be reported after a period of time
in the occurrence of high resource utilization.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->UPPB Resource Alarm

2-339
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.19 AMR-WB Parameter


2.19.1 Thresholds of AMR-WB (AmrWBThresholds)
Full Name

Thresholds of AMR-WB

Abbreviation

AmrWBThresholds

3GPP Name

threshold

3GPP Reference

45.009
This parameter determines the modified threshold in the mode.
It consists of eight bits, representing two thresholds of AMR WFS, four

Description

thresholds of AMR OWFS, and two thresholds of AMR OWHS.

Managed Object

BSC

Value Range and Step

0..63

Unit

0.5dB
TCH/WFS: 14, 20

Default Value

other: 6

Default Value
Configuration Reason

None

Configuration Rule and

Generally, it is not required to adjust the setting of this parameter unless

Adjustment Suggestion

the FER measured by the BTS exceeds 1%.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface, Abis Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->AMR-WB Parameter

2-340
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.19.2 Hysteresis of AMR-WB (AmrWBHysteresis)


Full Name

Hysteresis of AMR-WB

Abbreviation

AmrWBHysteresis

3GPP Name

hysteresis

3GPP Reference

45.009
This parameter determines the modified delay in the mode.
It consists of eight bits, representing two thresholds of AMR WFS, four

Description

thresholds of AMR OWFS, and two thresholds of AMR OWHS.

Managed Object

BSC

Value Range and Step

0..15

Unit

0.5dB

Default Value

6 for TCH/WFS, other: 3

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

None
By checking the frequency of rate adjustment, decide whether this
parameter is configured properly. When the rate is adjusted too
frequently, it is required to configure the parameter to a larger value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface, Abis Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->AMR-WB Parameter

Parameter Modifying
Version

None

2-341
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

2.20 Iur-g Parameter


2.20.1 Report characteristics (ReportType)
Full Name

Report characteristics

Abbreviation

ReportType

3GPP Name

Report characteristics

3GPP Reference

3GPP 25.423 8.5.2


This parameter determines the mode of reporting measurement reports.
The available options are as follows:
1 On Demand
2 Periodic

Description

7 Event E

Managed Object

BSC

Value Range and Step

1: On Demand 2: Period 7: EventE

Unit

None

Default Value

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.
To uninterruptedly reflect the load on the peer end by using the common

Configuration Rule and


Adjustment Suggestion

measurement reporting mode of the Iur-g interface, select "2" (Periodic).


To report measurement reports when certain conditions are met, select
"7" (Event E). To report measurement reports once, select "1" (On
Demand).

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-342
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Iur-g Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.20.2 Report periodicity unit (RepPeriodUnit)


Full Name

Report periodicity unit

Abbreviation

RepPeriodUnit

3GPP Name

None

3GPP Reference

None
When the common measurement mode is configured to "Periodic", this
parameter determines the unit of reporting interval.
1 10ms

Description

2 1Min

Managed Object

BSC

Value Range and Step

1: 10ms 2: 1Min

Unit

None

Default Value

Default Value
Configuration Reason

In the case of periodic reporting, the unit is second.


Generally, the period is short for periodic reporting, which helps reflect

Configuration Rule and


Adjustment Suggestion

the load on the peer end in real time. When the requirements on
the real-time load on the peer end are relatively low, the unit can be
changed to minute.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-343
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Iur-g Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.20.3 Report periodicity value (RepPeriodValue)


Full Name

Report periodicity value

Abbreviation

RepPeriodValue

3GPP Name

Report Periodicity Value

3GPP Reference

3GPP 25.423 9.1.48a


When the common measurement mode is configured to "Periodic", this
parameter determines the reporting interval.
When "RepPeriodUnit" is configured to "1", the step is 10ms and the
value ranges from 1 to 6000.
When "RepPeriodUnit" is configured to "2", the step is 1Min and the

Description

value ranges from 1 to 60.

Managed Object

BSC
When RepPeriodUnit is 1, the step is 10ms and the vale range is 1-6000.

Value Range and Step

When RepPeriodUnit is 2, the step is 1Min and the value range is 1-60.

Unit

None

Default Value

100

Default Value
Configuration Reason

Generally, measurement reports are reported every one second.


To use second or a unit lower than second as the reporting period,

Configuration Rule and


Adjustment Suggestion

configure "RepPeriodUnit" to "1". In this case, the value of this parameter


ranges from 1 to 6000 (10 ms to 60s). To use minute as the reporting
period, configure "RepPeriodUnit" to "2". In this case, the value of this
parameter ranges from 1 to 60 (1 minute to 60 minutes).

Change Mode

Offline

Related features

None

Related Parameters

RepPeriodUnit
When "RepPeriodUnit" is configured to "1", the step is 10ms and the

Relationship

value ranges from 1 to 6000. When "RepPeriodUnit" is configured to "2",


the step is 1 minute and the value ranges from 1 to 60.

Related Interfaces

None
2-344

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Iur-g Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.20.4 Load/RT Load/NRT Load measurement threshold 1


(MeasThr1_0~MeasThr1_2)
Full Name

Load/RT Load/NRT Load measurement threshold 1

Abbreviation

MeasThr1_0~MeasThr1_2

3GPP Name

Measurement Threshold 1

3GPP Reference

3GPP 25.423 9.1.39


This parameter determines reporting threshold 1 of event E. The
available thresholds for the Iur-g interface are Load, RT Load, and
NRT Load.
When the value is higher than this threshold, the system reports

Description

measurement reports.

Managed Object

BSC
Load Measurement Threshold 1: 0..100
RT Load Measurement Threshold 1: 0..100

Value Range and Step

NRT Load Measurement Threshold 1: 0..3

Unit

None
Load Measurement Threshold 1: 50
RT Load Measurement Threshold 1: 50

Default Value

NRT Load Measurement Threshold 1: 2

Default Value

It is required to configure this parameter according to the principle that

Configuration Reason

measurement reports are reported if the load exceeds 50%.

Configuration Rule and

To hope that event report is insensitive to load, increase event threshold

Adjustment Suggestion

1. Otherwise, decrease event threshold 1.

Change Mode

Offline

Related features

None

Related Parameters

None
2-345

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Iur-g Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.20.5 Load/RT Load/NRT Load measurement threshold 2


(MeasThr2_0~MeasThr2_2)
Full Name

Load/RT Load/NRT Load measurement threshold 2

Abbreviation

MeasThr2_0~MeasThr2_2

3GPP Name

Measurement Threshold 2

3GPP Reference

3GPP 25.423 9.1.39


This parameter determines reporting threshold 2 of event E. The
available thresholds for the Iur-g interface are Load, RT Load, and
NRT Load.
When the value is lower than this threshold, the system stops reporting

Description

measurement reports.

Managed Object

BSC
Load Measurement Threshold 1: 0..100
RT Load Measurement Threshold 1: 0..100

Value Range and Step

NRT Load Measurement Threshold 1: 0..3

Unit

None
Load Measurement Threshold 1: 40
RT Load Measurement Threshold 1: 40

Default Value

NRT Load Measurement Threshold 1: 1

Default Value
Configuration Reason

This threshold is lower than event threshold 1.

Configuration Rule and

To hope that event report is insensitive to load, decrease event threshold

Adjustment Suggestion

2. Otherwise, increase event threshold 2.

Change Mode

Offline
2-346

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related features

None

Related Parameters

MeasThr1

Relationship

The value is lower than that of MeasThr1.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Iur-g Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.20.6 Measurement hysteresis time (MeasHys,10ms)


Full Name

Measurement hysteresis time

Abbreviation

MeasHys

3GPP Name

Measurement Hysteresis Time

3GPP Reference

3GPP 25.423 9.1.36A


This parameter determines the delay time of reporting based on event
E. The system reports or stops reporting measurement reports after this

Description

delay time when the corresponding conditions are met.

Managed Object

BSC

Value Range and Step

1..6000

Unit

10ms

Default Value

100

Default Value
Configuration Reason

Generally, configure this parameter to 1s.

Configuration Rule and

To hope that the delay time of reporting based on event E is short,

Adjustment Suggestion

decrease this value. Otherwise, increase this value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

2-347
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Iur-g Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.20.7 Event report periodicity (EveRepPeriod,10ms)


Full Name

Event report periodicity

Abbreviation

EveRepPeriod

3GPP Name

Report Periodicity

3GPP Reference

3GPP 25.423 9.1.48A


This parameter determines the period of reporting based on event E when

Description

the event reporting conditions are met.

Managed Object

BSC

Value Range and Step

1..6000

Unit

10ms

Default Value

100

Default Value
Configuration Reason

Generally, measurement reports are reported every one second.

Configuration Rule and


Adjustment Suggestion

It is required to configure this parameter as required.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

2-348
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Iur-g Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.20.8 Measurement timer (MeasTimer,10ms)


Full Name

Measurement timer

Abbreviation

MeasTimer

3GPP Name

None

3GPP Reference

None
This parameter is a protection timer of measurement instances. This timer
is enabled when the system waits for responses of initialization or measurement report status. This timer restarts if no response or report is
received after the timeout time. In addition, this timer is disabled before

Description

instances are released.

Managed Object

BSC

Value Range and Step

1..65535

Unit

10ms

Default Value

500

Default Value
Configuration Reason

Generally, configure this parameter to 5s.

Configuration Rule and

This parameter is an internal parameter, and usually requires no

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Iur-g Parameter

2-349
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.20.9 Measurement max retry number (MeasMaxRetryNum)


Full Name

Measurement max retry number

Abbreviation

MeasMaxRetryNum

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum retry times when no response is
received after the timeout time configured for the protection timer of measurement instances. Alternatively, this parameter determines the maxi-

Description

mum restart times of the timer when no measurement report is received.

Managed Object

BSC

Value Range and Step

(1,2,3)

Unit

times

Default Value

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.

Configuration Rule and

This parameter is an internal parameter, and usually requires no

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Iur-g Parameter

Parameter Modifying
Version

iBSCV6.20.710

2-350
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Detail

New

2.20.10 Information report type (InfoReportType)


Full Name

Information report type

Abbreviation

InfoReportType

3GPP Name

None

3GPP Reference

None
This parameter determines the information reporting mode. 1: reported

Description

immediately; 3: reported after being modified

Managed Object

BSC

Value Range and Step

1: Ondemand 3: Periodic

Unit

None

Default Value

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.

Configuration Rule and

To hope that the information such as load on the peer end is reported

Adjustment Suggestion

after being modified, configure this parameter to 3.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Iur-g Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2-351
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.20.11 Measurement type (MeasType)


Full Name

Measurement type

Abbreviation

MeasType

3GPP Name

None

3GPP Reference

None

Description

RT Load; 7: NRT Load

Managed Object

BSC

Value Range and Step

2: Load 6: RT Load 7: NRT Load

Unit

None

Default Value

Default Value

This interface is designed for China Mobile only. Therefore, configure

Configuration Reason

this parameter according to the requirements of China Mobile.

This parameter determines the common measurement type. 2: Load; 6:

Configuration Rule and

According to the requirements of China Mobile, this parameter is not

Adjustment Suggestion

modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Iur-g Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.20.12 Support of 2g request Iur-g (IurgOf2gReq)


Full Name

Support of 2g request Iur-g

Abbreviation

IurgOf2gReq

3GPP Name

None
2-352

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

3GPP Reference

None
This parameter is a functional switch that determines whether the BSC
can acquire the information of Iur-g capacity and load from the RNC. The
original Iur-g functional switch still takes effect. It controls whether the
RNC acquires the capacity and load information from the BSC. The value
0 indicates that the BSC acquires data from the RNC. The value 1 indi-

Description

cates that the BSC acquires data from the RNC.

Managed Object

BSC

Value Range and Step

[0,1]

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and

To enable the Iur-g interface to acquire the information of 3G load,

Adjustment Suggestion

enable this switch.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Iur-g Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

2.21 Ater Timer Parameters


2.21.1 Ater wait SCCP connection timer (TAterWaitConn)
Full Name

Ater wait SCCP connection timer

Abbreviation

TAterWaitConn

2-353
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to wait for an SCCP CONNECT
CONFIRM message from the iTC in an SCCP connection establishment
process at the Ater interface.
Start: A SCCP CONNECT REQUEST message is sent to the iTC.
Stop:
The SCCP connection number corresponding to the service is invalid
when the iTC resource request of the service is processed.
An SCCP CONNECT CONFIRM message is received from the iTC.
At expiry: A DISCONNECT REQUEST message with the cause value of

Description

0x13 (normal) is sent to the SCCP to end the service at the Ater interface.

Managed Object

BSC
5..20

Value Range and Step

Step: 1

Unit

100 ms

Default Value

15

Default Value
Configuration Reason

1.5 seconds are enough to establish an SCCP connection to the iTC.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-05-02-002 Remote Transcoder Support

Related Parameters

None

Relationship

None

Related Interfaces

Ater

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Ater Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-354
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

2.21.2 Ater wait resource timer (TWaitAterRes)


Full Name

Ater wait resource timer

Abbreviation

TWaitAterRes

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to wait for a RESOURCE REQUEST
ACK message from the iTC in the resource request process at the Ater
interface.
Start: A RESOURCE REQUEST message is sent to the iTC of the Ater
interface.
Stop: The iTC of the Ater interface returns a RESOURCE AVAILABLE
message to the service.
At expiry: Release the service.

Description

Associated timer: None

Managed Object

BSC
10..30

Value Range and Step

Step: 1

Unit

100 ms

Default Value

20

Default Value

Two seconds are enough for the iTC to complete the resource

Configuration Reason

assignment and signalling transmission.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-05-02-003 Remote Transcoder Support

Related Parameters

None

Relationship

None

Related Interfaces

Ater

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Ater Timer

Parameter Modifying
Version

None

2-355
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

2.21.3 Ater wait resource release timer (TAterWaitRel)


Full Name

Ater wait resource release timer

Abbreviation

TAterWaitRel

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to wait for a RESOURCE RELEASE ACK
message from the iTC in a resource release process at the Ater interface.
Start: A RESOURCE RELEASE message is sent to the iTC of the Ater
interface.
Stop: A RESOURCE RELEASE ACK message is received from the iTC.
At expiry: Release the SCCP connection.

Description

Associated timer: None

Managed Object

BSC
20..50

Value Range and Step

Step: 1

Unit

100 ms

Default Value

20

Default Value
Configuration Reason

The default value is the same as TWaitAterRes.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-05-02-004 Remote Transcoder Support

Related Parameters

None

Relationship

None

Related Interfaces

Ater

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Ater Timer

2-356
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.21.4 Ater handover monitor timer (TAterMoniterHO)


Full Name

Ater handover monitor timer

Abbreviation

TAterMoniterHO

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to supervise a handover process at the
Ater interface when an external iTC is used.
Start: When the service requests for circuit resource again from the Ater
interface during the handover process.
Stop:
When an Ater interface handover execution message is received from
the old CS instance.
When an Ater interface resource release request message is received
from the new CS instance.
At expiry: The Ater interface sends a release command to the CS
service, and sends an iTC resource release message to the iTC.

Description

Associated timer: None

Managed Object

BSC
70..170

Value Range and Step

Step: 1

Unit

100 ms

Default Value

120

Default Value
Configuration Reason

12 seconds are enough for a handover process.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-05-02-005 Remote Transcoder Support

Related Parameters

None

Relationship

None

Related Interfaces

Ater

2-357
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Ater Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.21.5 Ater wait resource acknowledge timer (TWaitAterResAck)


Full Name

Ater wait resource acknowledge timer

Abbreviation

TWaitAterResAck

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to wait for the response from the iTC
when the iBSC requests resources from the iTC for handover.
Start: A CS service instance sends a RESOURCE REQUEST message
to the iTC.
Stop:
A RESOURCE REQUEST ACK message is received from the iTC.
A RESOURCE REQUEST FAILURE message is received from the iTC.
At expiry: Clear the number of the new RAN CS process corresponding
to the service process, or set the new RAN CS service instance
corresponding to the service process as non-existent.

Description

Associated timer: None

Managed Object

BSC
5..25

Value Range and Step

Step: 1

Unit

100 ms

Default Value

15

Default Value

1.5 seconds are enough for the iTC to complete the resource assignment

Configuration Reason

and signalling transmission.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-05-02-006 Remote Transcoder Support


2-358

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Ater

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Ater Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.21.6 Ater block circuit timer (TAterCicBlk)


Full Name

Ater block circuit timer

Abbreviation

TAterCicBlk

3GPP Name

None

3GPP Reference

None
This parameter is a timer for circuit blocking at the Ater interface, which
is used to wait for a BLOCKING ACK message or a UNBLOCKING
ACK message from the iTC.
Start: The BSC sends a single circuit blocking message to the iTC.
Stop: The BSC receives a single circuit blocking acknowledgement
message from the iTC.
At expiry: If the number of timer expiries does not exceed five, the BSC
sends the single circuit blocking message to the iTC again, and the
timer is restarted. When the number of timer expiries exceeds five, the
BSC terminates the instance.

Description

Associated timer: None

Managed Object

BSC
30..150

Value Range and Step

Step: 1

Unit

100 ms

Default Value

80

Default Value

Eight seconds are enough for signalling transmission and internal

Configuration Reason

processing of the iTC.


2-359

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-05-02-007 Remote Transcoder Support

Related Parameters

None

Relationship

None

Related Interfaces

Ater

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Ater Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.21.7 Ater block circuit group timer (TAterBlkCicGrp)


Full Name

Ater block circuit group timer

Abbreviation

TAterBlkCicGrp

3GPP Name

None

3GPP Reference

None
This parameter is a timer for circuit group blocking at the Ater interface,
which is used to wait for a BLOCKING CIRCUIT GROUP ACK message
or a UNBLOCKING CIRCUIT GROUP ACK message from the iTC.
Start: The BSC sends a circuit group blocking message to the iTC.
Stop: The BSC receives a circuit group blocking acknowledgement
message from the iTC.
At expiry: If the number of timer expiries does not exceed five, the BSC
sends the circuit group blocking message to the iTC again, and the timer
is restarted. When the number of timer expiries exceeds five, the BSC
terminates the instance.

Description

Associated timer: None

Managed Object

BSC
30..150

Value Range and Step

Step: 1
2-360

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Unit

100 ms

Default Value

80

Default Value

Eight seconds are enough for signalling transmission and internal

Configuration Reason

processing of the iTC.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-05-02-008 Remote Transcoder Support

Related Parameters

None

Relationship

None

Related Interfaces

Ater

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Ater Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.21.8 Ater reset circuit timer (TAterRstCic)


Full Name

Ater reset circuit timer

Abbreviation

TAterRstCic

3GPP Name

None

3GPP Reference

None
This parameter is a timer for circuit reset at the Ater interface, which is
used to wait for a RESET CIRCUIT ACK message from the iTC.
Start: The BSC sends a circuit reset message to the iTC.
Stop: The BSC receives a circuit reset acknowledgement message from
the iTC.
At expiry: If the number of timer expiries does not exceed five, the
BSC sends the circuit reset message to the iTC again, and the timer is
restarted. When the number of timer expiries exceeds five, the BSC
terminates the instance.

Description

Associated timer: None


2-361

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

BSC
30..150

Value Range and Step

Step: 1

Unit

100 ms

Default Value

80

Default Value

Eight seconds are enough for signalling transmission and internal

Configuration Reason

processing of the iTC.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-05-02-009 Remote Transcoder Support

Related Parameters

None

Relationship

None

Related Interfaces

Ater

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Ater Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.21.9 Ater reset timer (TAterRst)


Full Name

Ater reset timer

Abbreviation

TAterRst

3GPP Name

None

3GPP Reference

None

2-362
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

This parameter is a timer for the reset of the Ater interface, which is used
to wait for a RESET ACK message from the iTC.
Start: The BSC sends a RESET message to the iTC.
Stop: The BSC receives a RESET ACK message from the iTC.
At expiry: If the number of timer expiries does not exceed five, the BSC
sends the RESET message to the iTC again. When the number of timer
expiries reaches five, the BSC sets the number of no response times of
the opposite end to 0, and waits for the completion of the reset.
Description

Associated timer: None

Managed Object

BSC
60..150

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value

10 seconds are enough for signalling transmission and internal

Configuration Reason

processing of the iTC.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-05-02-010 Remote Transcoder Support

Related Parameters

None

Relationship

None

Related Interfaces

Ater

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Ater Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.21.10 Ater reset guard timer (TITCRst)


Full Name

Ater reset guard timer

Abbreviation

TITCRst
2-363

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

None

3GPP Reference

None
This parameter is a reset delay timer at the Ater interface, which is used
to delay the global reset for the release of resources.
Start: An Ater interface reset message is received.
Stop: None
At expiry: An Ater reset acknowledgement message is responded to

Description

the iTC.

Managed Object

BSC
30..60

Value Range and Step

Step: 1

Unit

100 ms

Default Value

40

Default Value

4 seconds are enough for signalling transmission and internal processing

Configuration Reason

of the iTC.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-05-02-011 Remote Transcoder Support

Related Parameters

None

Relationship

None

Related Interfaces

Ater

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Ater Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2.21.11 Ater block a interface circuit timer (TBlkACic)


Full Name

Ater block a interface circuit timer

Abbreviation

TBlkACic
2-364

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

3GPP Name

None

3GPP Reference

None
This parameter is a timer for blocking A interface circuit at the Ater
interface, which is used to wait for a BLOCKING A CIRCUIT ACK
message or a UNBLOCKING A CIRCUIT ACK message from the iTC.
Start: A circuit maintain request message is received.
Stop: A single circuit blocking acknowledgement message is received.
And a circuit un-equipped message is received.
At expiry: When the number of timer expiries reaches five, the circuit
instance at the Ater interface is terminated. A circuit maintain request

Description

message is sent to the iTC again, and the timer is restarted.

Managed Object

BSC
30..150

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value

10 seconds are enough for signalling transmission and internal

Configuration Reason

processing of the iTC.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-05-02-012 Remote Transcoder Support

Related Parameters

None

Relationship

None

Related Interfaces

Ater

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Ater Timer

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

2-365
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2.21.12 Ater block a interface circuit group timer (TBlkACicGrp)


Full Name

Ater block a interface circuit group timer

Abbreviation

TBlkACicGrp

3GPP Name

None

3GPP Reference

None
This parameter is a timer for blocking A interface circuit group at the Ater
interface, which is used to wait for a BLOCKING A CIRCUIT GROUP
ACK message or a UNBLOCKING A CIRCUIT GROUP ACK message
from the iTC.
Start: A circuit group maintain request message is received.
Stop: A circuit group blocking acknowledgement message is received.
And a circuit un-equipped message is received.
At expiry: When the number of timer expiries reaches five, the circuit
instance at the Ater interface is terminated. A circuit maintain request

Description

message is sent to the iTC again, and the timer is restarted.

Managed Object

BSC
30..150

Value Range and Step

Step: 1

Unit

100 ms

Default Value

100

Default Value

10 seconds are enough for signalling transmission and internal

Configuration Reason

processing of the iTC.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended.

Change Mode

Offline

Related features

ZGO-05-02-013 Remote Transcoder Support

Related Parameters

None

Relationship

None

Related Interfaces

Ater

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Ater Timer

Parameter Modifying
Version

None

2-366
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 2 BSC Function Parameters

Parameter Modifying
Detail

None

2-367
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This page intentionally left blank.

2-368
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3

External Cell Parameters


Table of Contents
GERAN External Cell Parameters ..............................................................................3-1
UTRAN External Cell Parameters.............................................................................3-40
LTE External Cell Parameters ..................................................................................3-65

3.1 GERAN External Cell Parameters


3.1.1 User Label
Full Name

User Label

Abbreviation

UserLabel

3GPP Name

None

3GPP Reference

None

Description

This parameter means the GERAN external cell name for users to identify.

Managed Object

Cell

Value Range and


Step

Character string with the maximum length of 40

Unit

None

Default Value

None

Default Value
Configuration
Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

3-1
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->External Cell Config->GERAN External Cell Con-

OMC Access Path

fig->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.2 External cell ID (Geran EcellID)


Full Name

External cell ID

Abbreviation

Geran EcellID

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the external cell number.

Managed Object

Cell

Value Range and Step

1.0.65535; step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

3-2
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.3 Cell type (CellType)


Full Name

Cell type

Abbreviation

CellType

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the GERAN External Cell type.

Managed Object

Cell

Value Range and Step

Umbrella cell, Macro Cell, Micro Cell, Micro-micro Cell, Extended Cell

Unit

None

Default Value

Macro Cell

Default Value
Configuration Reason

None

Configuration Rule and

This parameter just indicates the type of external adjacent cells. It does

Adjustment Suggestion

not impact the services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->Basic Property

3-3
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.4 MCC (MCC)


Full Name

MCC

Abbreviation

MCC

3GPP Name

None

3GPP Reference

None
A Mobile Country Code (MCC) consists of three decimal digits and is used

Description

to uniquely identify the country where a mobile user (or system) belongs.

Managed Object

Cell

Value Range and Step

0..999; Step: 1

Unit

None

Default Value

460

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Config->Basic Property
Parameter Modifying
Version

None

3-4
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Parameter Modifying
Detail

None

3.1.5 MNC (MNC)


Full Name

MNC

Abbreviation

MNC

3GPP Name

None

3GPP Reference

None
A Mobile Network Code (MNC) consists of three decimal digits and is
used to uniquely identify a specific GSM PLMN in a country (depending

Description

on MCC).

Managed Object

Cell
If MNC3Digits is set to "2 digits", the value range will be 0 to 99.

Value Range and Step

If MNC3Digits is set to "3 digits", the value range will be 0 to 999.

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

[BSC]MNC3Digits
If MNC3Digits is set to "2 digits", the MNC can only be two digits long. If

Relationship

MNC3Digits is set to "3 digits", the MCN can only be three digits long.
If MNC3Digits is set to "2 or 3 digits", the MNC can be two or three
digits long.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Config->Basic Property

3-5
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.6 FreqBand (FreqBand)


Full Name

FreqBand

Abbreviation

FreqBand

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the frequency band of the system.

Managed Object

Cell
When the value of DCS1800/PCS1900 supported (FuncExt) is
DCS1800, the value range is GSM900, EXT900, PCS1900, GSM850;
When the value of DCS1800/PCS1900 supported (FuncExt) is

Value Range and Step

PCS1900, it value range is GSM900, EXT900, PCS1900, GSM850;

Unit

None

Default Value

GSM900

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

[Cell]BcchArfcn

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->Basic Property

Parameter Modifying
Version

None
3-6

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Parameter Modifying
Detail

None

3.1.7 BCCH arfcn (BcchArfcn)


Full Name

BCCH arfcn

Abbreviation

BcchArfcn

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the ARFCN of the BCCH carrier in the cell.

Managed Object

Cell
When FreqBand is set to "GSM900", the value range will be 1 to 124.
When FreqBand is set to "EXT900", the value range will be 0 to 124
and 975 to 1023.
When FreqBand is set to "PCS1900", the value range will be 512 to 810.
When FreqBand is set to "DCS1800", the value range will be 512 to 885.

Value Range and Step

When FreqBand is set to GSM850, the value range will be 128 to 251.

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->Basic Property

Parameter Modifying
Version

None
3-7

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

3.1.8 LAC (LAC)


Full Name

LAC

Abbreviation

LAC

3GPP Name

None

3GPP Reference

None
Each GSM PLMN is divided into many location areas to locate mobile
stations. Location area codes (LACs) are used to identify different
location areas. LAC is part of LAI (LAI = MCC + MNC + LAC). One
location area contains multiple cells.

Description

This parameter must be consistent with that configured at the CN side.

Managed Object

Cell
1..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->Basic Property

Parameter Modifying
Version

None
3-8

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Parameter Modifying
Detail

None

3.1.9 CI (CI)
Full Name

CI

Abbreviation

CI

3GPP Name

None

3GPP Reference

None
Network operators must allocate a unique code to each cell in a location

Description

area to identify every cell.

Managed Object

Cell
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Config->Basic Property
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3-9
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3.1.10 NCC (NCC)


Full Name

NCC

Abbreviation

NCC

3GPP Name

None

3GPP Reference

None
Network Color Code (NCC) is part of Base Station Identity Code (BSIC)
(BSIC = NCC + BCC). It is used by mobile stations to differentiate adjacent cells that belong to different GSM PLMNs. Generally, neighboring
operators are required to use different NCCs. The parameter relating to
NCC is "NccPermitted". Prohibiting mobile stations to report NCCs in a
cell is a way to prevent the mobile stations from measuring the cell information of related operators. An NCC has three bits and is one of the

Description

network identification parameters.

Managed Object

Cell
0..7

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->Basic Property

Parameter Modifying
Version

None

3-10
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Parameter Modifying
Detail

None

3.1.11 BCC (BCC)


Full Name

BCC

Abbreviation

BCC

3GPP Name

None

3GPP Reference

None
Base Station Color Code (BCC) is part of Base Station Identity Code
(BSIC) (BSIC = NCC + BCC). Generally, BCC is used by mobile stations
to differentiate adjacent cells that have the same BCCH carrier frequency
and belong to the same GSM PLMN. In addition, according to GSM specifications, the Training Sequence Code (TSC) of the broadcast control
channel of a cell must be equal to the BCC of the cell. A BCC has three

Description

bits and is one of the network identification parameters.

Managed Object

Cell
0..7

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->Basic Property

3-11
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.12 GPRS service support (PsSupport)


Full Name

GPRS service support

Abbreviation

PsSupport

3GPP Name

None

3GPP Reference

None

Description

This parameter describes whether the cell supports GPRS.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The default value is dependent upon the actual configuration

Configuration Reason

requirement.

Configuration Rule and

This parameter is selected by the adjacent cell. This cell is selected

Adjustment Suggestion

during the reselection of the GPRS service cell.

Change Mode

Offline

Related features

None

Related Parameters

[Ts]TS Channel Combination


If "GPRS Supported (PsSupport)" is No, that is, GPRS is not supported,

Relationship

the system automatically changes all timeslot channels whose type is


PS in the cell to TCH.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->Basic Property

Parameter Modifying
Version

None

3-12
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Parameter Modifying
Detail

None

3.1.13 Cell reselection offset (ReselOff_0)


Full Name

Cell reselection offset

Abbreviation

ReselOff_0

3GPP Name

GPRS_RESELECT_OFFSET

3GPP Reference

3GPP TS 45.008 V5.22.0


GPRS offset during reselection is the parameter used at the MS side. It
is broadcast to MS via PBCCH system message from BTS. In the GPRS
system, C32 is used as the standard for cell reselection.
C32(s) = C1(s) (serving cell)
C32(n) = C1(n) + GPRS_RESELECT_OFFSET(n) - TO(n) * (1-L(n))
(adjacent cell)
TO(n) = GPRS_TEMPORARY_OFFSET(n) *
H(GPRS_PENALTY_TIME(n) - T(n)).
L(n) = 0 , if PRIORITY_CLASS(n) = PRIORITY_CLASS(s)
1 , if PRIORITY_CLASS(n) PRIORITY_CLASS(s)
H(x) = 0 , x < 0
1, x >= 0
GPRS_RESELECT_OFFSET provides the offset value and hysteresis
value for each cell;
GPRS_TEMPORARY_OFFSET indicates a temporary reselection
offset. which is a negative one in C32. The effective time depends on
the penalty time parameter of cell reselection.
GPRS_PENALTY_TIME indicates the effective period of time of the
temporary reselection offset.
PRIORITY_CLASS is an HCS priority for a cell.
This parameter is used during reselection in idle status. It is enabled

Description

only when PBCCH is configured.

Managed Object

Cell

Value Range and Step

0..31

Unit

None

Default Value

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.

Configuration Rule and


Adjustment Suggestion

The priority of access to a cell becomes higher if this parameter is set


higher, and it becomes easier for MS to handover to this cell during
reselection.
3-13

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Config->GPRS Property
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.14 Cell reselection offset (ReselOff_1)


Full Name

Cell reselection offset

Abbreviation

ReselOff_1

3GPP Name

GPRS_RESELECT_OFFSET

3GPP Reference

3GPP TS 45.008 V5.22.0


GPRS offset during reselection is the parameter used at the MS side. It
is broadcast to MS through PBCCH system message from BTS. In the
GPRS system, C32 is used as the standard for cell reselection.
C32(s) = C1(s) (serving cell)
C32(n) = C1(n) + GPRS_RESELECT_OFFSET(n) - TO(n) * (1-L(n))
(adjacent cell)
TO(n) = GPRS_TEMPORARY_OFFSET(n) *
H(GPRS_PENALTY_TIME(n) - T(n)).
L(n) = 0 , if PRIORITY_CLASS(n) = PRIORITY_CLASS(s)
1 , if PRIORITY_CLASS(n) PRIORITY_CLASS(s)
H(x) = 0 , x < 0
1, x >= 0
GPRS_RESELECT_OFFSET provides the offset value and hysteresis

Description

value for each cell;

3-14
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

GPRS_TEMPORARY_OFFSET indicates a temporary reselection


offset. which is a negative one in C32. The effective time depends on
the penalty time parameter of cell reselection.
GPRS_PENALTY_TIME indicates the effective period of time of the
temporary reselection offset.
PRIORITY_CLASS is an HCS priority for a cell.
This parameter indicates the parameter used during reselection in
transmission state.
Managed Object

Cell

Value Range and Step

0..31

Unit

None

Default Value

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.

Configuration Rule and


Adjustment Suggestion

The priority of access to a cell becomes higher if this parameter is set


higher, and it becomes easier for MS to handover to this cell during
reselection.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.15 Cell reselection temporary offset (TempOffset_0)


Full Name

Cell reselection temporary offset

Abbreviation

TempOffset_0
3-15

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

GPRS_TEMPORARY_OFFSET

3GPP Reference

3GPP TS 45.008 V5.22.0


GPRS offset during reselection is the parameter used at the MS side. It
is broadcast to MS via PBCCH system message from BTS. In the GPRS
system, C32 is used as the standard for cell reselection.
C32(s) = C1(s) (serving cell)
C32(n) = C1(n) + GPRS_RESELECT_OFFSET(n) - TO(n) * (1-L(n))
(adjacent cell)
TO(n) = GPRS_TEMPORARY_OFFSET(n) *
H(GPRS_PENALTY_TIME(n) - T(n)).
L(n) = 0 , if PRIORITY_CLASS(n) = PRIORITY_CLASS(s)
1 , if PRIORITY_CLASS(n) PRIORITY_CLASS(s)
H(x) = 0 , x < 0
1, x >= 0
GPRS_RESELECT_OFFSET provides the offset value and hysteresis
value for each cell;
GPRS_TEMPORARY_OFFSET indicates a temporary reselection
offset. which is a negative one in C32. The effective time depends on
the penalty time parameter of cell reselection.
GPRS_PENALTY_TIME indicates the effective period of time of the
temporary reselection offset.
PRIORITY_CLASS is an HCS priority for a cell.
This parameter is used during reselection in idle status. It is enabled

Description

only when PBCCH is configured.

Managed Object

Cell

Value Range and Step

(0, 10, 20, 30, 40, 50, 60, positive infinite)

Unit

dB

Default Value

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.


This parameter is used to prevent toggle reselections when an MS is

Configuration Rule and

moving fast. An MS will not choose this cell if the BCCH signal intensity

Adjustment Suggestion

last for less than the PenaltyTime parameter. The parameter can be set
as the maximum value 60 (GSM signal strength is 0 .. 63).

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

3-16
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.16 Cell reselection temporary offset (TempOffset_1)


Full Name

Cell reselection temporary offset

Abbreviation

TempOffset_1

3GPP Name

GPRS_TEMPORARY_OFFSET

3GPP Reference

3GPP TS 45.008 V5.22.0


GPRS offset during reselection is the parameter used at the MS side. It
is broadcast to MS through PACCH system message from BTS. In the
GPRS system, C32 is used as the standard for cell reselection.
C32(s) = C1(s) (serving cell)
C32(n) = C1(n) + GPRS_RESELECT_OFFSET(n) - TO(n) * (1-L(n))
(adjacent cell)
TO(n) = GPRS_TEMPORARY_OFFSET(n) *
H(GPRS_PENALTY_TIME(n) - T(n)).
L(n) = 0 , if PRIORITY_CLASS(n) = PRIORITY_CLASS(s)
1 , if PRIORITY_CLASS(n) PRIORITY_CLASS(s)
H(x) = 0 , x < 0
1, x >= 0
GPRS_RESELECT_OFFSET provides the offset value and hysteresis
value for each cell;
GPRS_TEMPORARY_OFFSET indicates a temporary reselection
offset. which is a negative one in C32. The effective time depends on
the penalty time parameter of cell reselection.
GPRS_PENALTY_TIME indicates the effective period of time of the
temporary reselection offset.
PRIORITY_CLASS is an HCS priority for a cell.
This parameter indicates the parameter used during reselection in

Description

transmission state.

Managed Object

Cell
3-17

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Value Range and Step

(0, 10, 20, 30, 40, 50, 60, positive infinite)

Unit

dB

Default Value

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.


This parameter is used to prevent toggle reselections when an MS is

Configuration Rule and

moving fast. An MS will not choose this cell if the BCCH signal intensity

Adjustment Suggestion

last for less than the PenaltyTime parameter. The parameter can be set
as the maximum value 60 (GSM signal strength is 0 .. 63).

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.17 Penalty time of cell reselection (PenalTime_0)


Full Name

Penalty time of cell reselection

Abbreviation

PenalTime_0

3GPP Name

GPRS_PENALTY_TIME

3GPP Reference

3GPP TS 45.008 V5.22.0

3-18
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

GPRS penalty time during reselection is the parameter used at the MS


side. It is broadcast to MS via PBCCH system message from BTS. In
the GPRS system, C32 is used as the standard for cell reselection.
C32(s) = C1(s) (serving cell)
C32(n) = C1(n) + GPRS_RESELECT_OFFSET(n) - TO(n) * (1-L(n))
(adjacent cell)
TO(n) = GPRS_TEMPORARY_OFFSET(n) *
H(GPRS_PENALTY_TIME(n) - T(n)).
L(n) = 0 , if PRIORITY_CLASS(n) = PRIORITY_CLASS(s)
1 , if PRIORITY_CLASS(n) PRIORITY_CLASS(s)
H(x) = 0 , x < 0
1, x >= 0
GPRS_RESELECT_OFFSET provides the offset value and hysteresis
value for each cell;
GPRS_TEMPORARY_OFFSET indicates a temporary reselection
offset. which is a negative one in C32. The effective time depends on
the penalty time parameter of cell reselection.
GPRS_PENALTY_TIME indicates the effective period of time of the
temporary reselection offset.
PRIORITY_CLASS is an HCS priority for a cell.
This parameter is used during reselection in idle status. It is enabled
Description

only when PBCCH is configured.

Managed Object

Cell

Value Range and Step

0..31

Unit

10 s

Default Value

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.


The coverage area and mobility statistical data should be taken into

Configuration Rule and


Adjustment Suggestion

consideration when setting this parameter. If a fast-moving MS is not


expected to access a micro-cell, the penalty time should be longer when
the micro-cell becomes bigger.For regular micro-cell, it is recommended
to set this parameter 20.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

3-19
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.18 Penalty time of cell reselection (PenalTime_1)


Full Name

Penalty time of cell reselection

Abbreviation

PenalTime_1

3GPP Name

GPRS_PENALTY_TIME

3GPP Reference

3GPP TS 45.008 V5.22.0


GPRS penalty time during reselection is the parameter used at the MS
side. It is broadcast to MS through PACCH system message from BTS.
In the GPRS system, C32 is used as the standard for cell reselection.
C32(s) = C1(s) (serving cell)
C32(n) = C1(n) + GPRS_RESELECT_OFFSET(n) - TO(n) * (1-L(n))
(adjacent cell)
TO(n) = GPRS_TEMPORARY_OFFSET(n) *
H(GPRS_PENALTY_TIME(n) - T(n)).
L(n) = 0 , if PRIORITY_CLASS(n) = PRIORITY_CLASS(s)
1 , if PRIORITY_CLASS(n) PRIORITY_CLASS(s)
H(x) = 0 , x < 0
1, x >= 0
GPRS_RESELECT_OFFSET provides the offset value and hysteresis
value for each cell;
GPRS_TEMPORARY_OFFSET indicates a temporary reselection
offset. which is a negative one in C32. The effective time depends on
the penalty time parameter of cell reselection.
GPRS_PENALTY_TIME indicates the effective period of time of the
temporary reselection offset.
PRIORITY_CLASS is an HCS priority for a cell.
This parameter indicates the parameter used during reselection in

Description

transmission state.

Managed Object

Cell

Value Range and Step

0..31
3-20

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Unit

10 s

Default Value

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.


The coverage area and mobility statistical data should be taken into

Configuration Rule and


Adjustment Suggestion

consideration when setting this parameter. If a fast-moving MS is not


expected to access a micro-cell, the penalty time should be longer when
the micro-cell becomes bigger.For regular micro-cell, it is recommended
to set this parameter 20.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.19 HSC exist (HCS_EXIST_0)


Full Name

HSC exist

Abbreviation

HCS_EXIST_0

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the HCS(Hierarchical Cell Structure)
parameter (HCS priority and HCS signal strength threshold) exists. If this
cell does not use HCS parameters, an MS will ignore HCS parameters
of other cells, then all cells use infinite threshold of HCS signal strength
threshold. This parameter indicates the parameter used during reselec-

Description

tion in transmission state.


3-21

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.


When the radio network have different cell reselection priority, set

Configuration Rule and


Adjustment Suggestion

this parameter "Yes" if the C31 judgment criteria for the priority cell
reselection and signal level threshold are applied. When more than
one cell has the highest priority, C32 judgment criteria should be used
for the cells with a same priority.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.20 HSC exist (HCS_EXIST_1)


Full Name

HSC exist

Abbreviation

HCS_EXIST_1

3GPP Name

None

3GPP Reference

None

3-22
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

This parameter indicates whether the HCS(Hierarchical Cell Structure)


parameter (HCS priority and HCS signal strength threshold) exists. If this
cell does not use HCS parameters, an MS will ignore HCS parameters
of other cells, then all cells use infinite threshold of HCS signal strength
threshold. This parameter indicates the parameter used during reselecDescription

tion in transmission state.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.


When the radio network have different cell reselection priority, set

Configuration Rule and


Adjustment Suggestion

this parameter "Yes" if the C31 judgment criteria for the priority cell
reselection and signal level threshold are applied. When more than
one cell has the highest priority, C32 judgment criteria should be used
for the cells with a same priority.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.21 Threshold of HSC signal level (HCS_THR_0)


Full Name

Threshold of HSC signal level

Abbreviation

HCS_THR_0
3-23

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

HCS_THR

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. This is a Hierarchical Cell Structure (HCS) parameter and the parameter information is broadcast to MS
through PBCCH system message from BTS. It indicates the HCS signal
strength threshold of the cell. This parameter indicates the parameters
used during reselection on idle status, which only functions while config-

Description

uring PBCCH.

Managed Object

Cell

Value Range and Step

0..31

Unit

None

Default Value

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.

Configuration Rule and


Adjustment Suggestion

The parameter indicates the minimum access electricity level threshold.


It is easier to access a cell when the threshold gets lower. Increase the
threshold to limit the MS access to a cell.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.22 Threshold of HSC signal level (HCS_THR_1)


Full Name

Threshold of HSC signal level

3-24
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Abbreviation

HCS_THR_1

3GPP Name

HCS_THR

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. This is a Hierarchical Cell Structure
(HCS) parameter and the parameter information is passed to MS through
PACCH. It indicates the HCS signal strength threshold of the cell. This
parameter indicates the parameter used during reselection in transmis-

Description

sion state.

Managed Object

Cell

Value Range and Step

0..31

Unit

None

Default Value

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.

Configuration Rule and


Adjustment Suggestion

The parameter indicates the minimum access electricity level threshold.


It is easier to access a cell when the threshold gets lower. Increase the
threshold to limit the MS access to a cell.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.23 HCS priority (PrioClass_0)


Full Name

HCS priority
3-25

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

PrioClass_0

3GPP Name

PRIORITY_CLASS

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. This is a Hierarchical Cell Structure (HCS) parameter and the parameter information is broadcast to MS
through PBCCH system message from BTS. This parameter indicates the
parameters used during reselection on idle status, which only functions

Description

while configuring PBCCH.

Managed Object

Cell

Value Range and Step

0..7

Unit

None

Default Value

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.

Configuration Rule and

The priority of an HCS cell gets higher with the increase of the parameter

Adjustment Suggestion

value.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.24 HCS priority (PrioClass_1)


Full Name

HCS priority

Abbreviation

PrioClass_1
3-26

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

3GPP Name

PRIORITY_CLASS

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. This is a Hierarchical Cell Structure
(HCS) parameter and the parameter information is passed to MS through
PACCH. It indicate the HCS priority. This parameter indicates the param-

Description

eter used during reselection in transmission state.

Managed Object

Cell

Value Range and Step

0..7

Unit

None

Default Value

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.

Configuration Rule and

The priority of an HCS cell gets higher with the increase of the parameter

Adjustment Suggestion

value.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Config->GPRS Property
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.25 Allow SOLSA MS to access (EXC_ACC)


Full Name

Allow SOLSA MS to access

Abbreviation

EXC_ACC

3GPP Name

EXC_ACC

3-27
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is sent to an MS through PSI3 and PSI3bis system messages on PBCCH; when PBCCH does not exist, the parameter is sent to
an MS through PACKET CELL CHANGE ORDER messages or PACKET
MEASUREMENT ORDER messages on PACCH. This parameter is used
to prevent MSs without SoLSA access authorization from staying in a cell.
0 indicates MSs with SoLSA access authorization will not access; 1 indicates MSs with SoLSA access authorization will access. SoLSA: Support
of Localised Service Area, which consists of one cell or a series of cells.

Description

These cells can be covered inconsecutively.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

Usually MSs with SoLSA access authorization are not prevented from

Configuration Reason

staying in a cell.

Configuration Rule and

If MSs with SoLSA access authorization are expected to access a cell,

Adjustment Suggestion

set this parameter "Yes".

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.26 Cell reselection status (CellBarAc2)


Full Name

Cell reselection status


3-28

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Abbreviation

CellBarAc2

3GPP Name

CELL_BAR ACCESS_2

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter indicates the MS access authorization to a cell. 0
indicates an MS can access the cell; 1 indicates an MS cannot access
the cell. This parameter is broadcast to MS on PBCCH. The parameter
together with CELL_BAR_ACCESS(CBA access forbidden) and
CELL_BAR_QULIFY (CBQ access forbidden) determines the reselection
state. The correlations between CBA2, cell reselection priority and cell
reselection state are shown in table 1: CELL_BAR ACCESS_2 (CBA2)
cell reselection priority cell reselection state
No Normal Normal
Yes Forbidden Forbidden
The parameter CBA2, together with CBQ and CBA, determine the cell
reselection priority and cell reselection state, as shown in Table 2:
CBQ3 CBQ CBA cell reselection priority cell reselection state
XX No No Normal Normal
XX No Yes Forbidden Forbidden
XX Yes No Low Normal
XX Yes No Low Normal
Note: If the following conditions are fulfilled, the cell reselection priority
and cell reselection state are normal.
? The cell belongs to the PLMN that MSs camps on.
The MS is in test operation mode.
? The cell access forbidden parameter is set "YES".
The cell access forbidden parameter is set "NO".

Description

The access control level "15" is forbidden.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

This parameter is relevant to PBCCH channel configuration, and is not

Configuration Reason

recommended to be used.

3-29
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The parameter that controls the cell access forbidden bit can be
configured by network administrator. Usually all cells allows MS access,
so the bit should be set 0. Under special circumstances, a cell is
expected to serve for handover services, then the bit can be set 1 (CBQ
should be 0), as shown in Figure 1.
Figure 1 Diagram of cell access forbidden
Suppose the areaA (the shadowed area) is the busy area (commercial
area in big city). To raise the accessibility of the area with limited
frequency resources, micro-cell coverage can be applied. To lower the
number of times of cross-cell handover when an MS is in high-mobility
state, two layer network concept is applied, that is, setting up a BTS A
Configuration Rule and
Adjustment Suggestion

(the volume can be smaller) which covers the whole area A. Usually MSs
all works in a micro-cell (the cell priority and the reselection parameter
can be configured for implementation). When an MS is in high-mobility
state in a call, it is forced to handover to BTS A. If an MS stays at BTS A
and at the edge of a micro-cell, the MS will not start the cell reselection
procedure because the signal quality of BTS A is much better than that
of the micro-cell BTS. In this case the congestion in the BTS A will
happen because the volume of the BTS A is small. The method to solve
this problem is to set the cell access forbidden parameter to 1, that is,
the MS is forbidden to access the BTS A and only the services can be
handed over into the coverage area of the the BTS A.
Precautions:
The cell access forbidden functional parameter is only used in some
special situations. Usually it is set to 0.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]CellBarAccess
[Cell]CellBarQualify
The parameterr together with CBQ and CBA, determine the cell
reselection priority and cell reselection state, as shown in the table: CBQ
CBA cell reselection priority cell reselection state
No No Normal Normal
No Yes Forbidden Forbidden
Yes No Low Normal

Relationship

Yes Yes Low Normal


Note: If the following conditions are fulfilled, the cell reselection priority
and cell reselection state are normal.
? The cell belongs to the PLMN that MSs camps on.
The MS is in test operation mode.
? The cell access forbidden parameter is set "YES".
The cell access forbidden parameter is set "NO".
The access control level "15" is forbidden.

3-30
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.27 LSA ID (LSA_Id)


Full Name

LSA ID

Abbreviation

LSA_Id

3GPP Name

LSA ID

3GPP Reference

3GPP TS 45.008 V5.22.0


LSA is broadcast to an MS through SI4 messages on BCCH. This parameter indicates the LSA marks of a cell. SoLSA: Support of Localised
Service Area, which consists of one cell or a series of cells. These cells

Description

can be covered inconsecutively.

Managed Object

Cell

Value Range and Step

0..16777215

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

This parameter should be configured according to network operation

Adjustment Suggestion

planning.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

3-31
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.28 RAC (RAC)


Full Name

RAC

Abbreviation

RAC

3GPP Name

None

3GPP Reference

None
Compared with the GSM system that uses location areas to manage a
group of cells, GPRS divides a location area to several routing areas
that are identified by RAI (MCC + MNC + LAC + RAC). When a mobile
station in attach status carries out a cell reselection, it will initiate a
"Routing Area Update" process if the RAI of the new cell is different from
that of the old cell.
The SGSN has the routing area information of the MSs that are in
standby status. Therefore, when packet data or circuit data is transmitted
in the network, the MSs will be paged in the routing area. Cross-SGSN
RAI cannot be used.

Description

This parameter must be consistent with that configured at the CN side.

Managed Object

Cell
0..255

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline
3-32

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Config->Basic Property
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.29 Access minimal signal level (RxLevAsMin_0)


Full Name

Access minimal signal level

Abbreviation

RxLevAsMin_0

3GPP Name

GPRS_RXLEV_ACCESS_MIN

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. It is broadcast to an MS through
system packet messages on PBCCH by BTS. This parameter indicates
the minimum receiving level for MS access to this system (GPRS).
To prevent the MS from accessing the system at a low receiving
signal level (usually, the communication quality cannot guarantee
normal communication), which will cause unreasonable waste of radio
resources. It is stipulated in the GSM system design that the receiving
level should be greater than a threshold level for MS to access the
network, that is, the minimum level for an MS to access a cell.
In addition, this parameter also serves as one of the standards for an
MS to make the cell selection and re-selection (a parameter used to
calculate C31 and C32). This parameter indicates the parameters used
during reselection on idle status, which only functions while PBCCH

Description

has been configured.

Managed Object

Cell

3-33
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0..63
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
2: -109 dBm .. -108 dBm;
...
62: -49 dBm .. -48 dBm;
63: > -48 dBm
Value Range and Step

Step: 1

Unit

None

Default Value

12

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.


It is advised to set this parameter to approximate MS receiving sensitivity.
For some cells with traffic overload, increase the minimum access level
to decrease C1 and C32 value of the cell, and the cell coverage range
decreases at the same time. Setting the minimum access level too large

Configuration Rule and


Adjustment Suggestion

will cause crossover area of cells to become "dead area".


The level should not exceed -90 dBm for cell traffic balancing conditions.
At the preliminary running stage of the network, this parameter can be
usually set as 10 (that is, -101 dBm .. -100 dBm) or lower, which is
higher than the MS receiving sensitivity -102 dBm. However, when the
network capacity is expanded or the radio coverage in a cell is not a
problem, this parameter of the cell can be increased by 2.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3-34
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

3.1.30 Access minimal signal level (RxLevAsMin_1)


Full Name

Access minimal signal level

Abbreviation

RxLevAsMin_1

3GPP Name

GPRS_RXLEV_ACCESS_MIN

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. It is broadcast to an MS through
system packet messages on PBCCH by BTS. This parameter indicates
the minimum receiving level for MS access to this system (GPRS).
To prevent the MS from accessing the system at a low receiving
signal level (usually, the communication quality cannot guarantee
normal communication), which will cause unreasonable waste of radio
resources. It is stipulated in the GSM system design that the receiving
level should be greater than a threshold level for MS to access the
network, that is, the minimum level for an MS to access a cell.
In addition, this parameter also serves as one of the standards for an
MS to make the cell selection and re-selection (a parameter used to
calculate C31 and C32).
This parameter indicates the parameter used during reselection in

Description

transmission state.

Managed Object

Cell
0..63
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
2: -109 dBm .. -108 dBm;
...
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

12

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.

3-35
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

It is advised to set this parameter to approximate MS receiving sensitivity.


For some cells with traffic overload, increase the minimum access level
to decrease C1 and C32 value of the cell, and the cell coverage range
decreases at the same time. Setting the minimum access level too large
Configuration Rule and
Adjustment Suggestion

will cause crossover area of cells to become "dead area".


The level should not exceed -90 dBm for cell traffic balancing conditions.
At the preliminary running stage of the network, this parameter can be
usually set as 10 (that is, -101 dBm .. -100 dBm) or lower, which is
higher than the MS receiving sensitivity -102 dBm. However, when the
network capacity is expanded or the radio coverage in a cell is not a
problem, this parameter of the cell can be increased by 2.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.31 Maximum initial access signal level (MsTxMaxCCH_0)


Full Name

Maximum initial access signal level

Abbreviation

MsTxMaxCCH_0

3GPP Name

GPRS_MS_TXPWR_MAX_CCH

3GPP Reference

3GPP TS 45.008 V5.22.0

3-36
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

This parameter is used at MS side. It is broadcast to an MS through


system packet messages on PBCCH by BTS. Network controls the
MS transmit power during communication between MS with BTS. MS
power control is implemented with power control commands. MS output
transmit power must meet the radio network standard. If an MS cannot
output this power because of low power level, it gives an power closest
to the standard.
This parameter is also used for MS cell selection and re-selection,
involved in the calculation of C1 and C2 values.
Refer to appendix C, for the maximum power before MS receives the
power control information.
The setting for this parameter should follow this principle: guarantee a
certain success rate of MS access at the cell edge while decreasing the
access level of MS as much as possible. Generally, it is recommended
to set this parameter to 5 (for GSM900MS) and 2 (for GSM1800MS).
After the parameter is set, make a dial test at the cell boundary. Test the
success rate of MS access and access time under different parameter
settings to determine whether to increase or decrease the value of the
parameter.
This parameter is used during reselection in idle status. It is enabled
Description

only when PBCCH is configured.

Managed Object

Cell

Value Range and Step

0..31

Unit

None

Default Value

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.


If this parameter value is too high, the MS close to BTS will disturb the
adjacent channel; if the value is too low, the success rate of MS access
at the edge of cell will be low.
The setting for this parameter should follow this principle: guarantee a
certain success rate of MS access at the cell edge while decreasing the

Configuration Rule and

access level of MS as much as possible. Obviously, the coverage area

Adjustment Suggestion

increases with the uplift of MS output power. It is recommended to set


this parameter 5 (for GSM900MS) and 0 (for GSM1800MS).
After the parameter is set, make a dial test at the cell boundary. Test the
success rate of MS access and access time under different parameter
settings to determine whether to increase or decrease the value of the
parameter.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

3-37
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Config->GPRS Property
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.1.32 Maximum initial access signal level (MsTxMaxCCH_1)


Full Name

Maximum initial access signal level

Abbreviation

MsTxMaxCCH_1

3GPP Name

GPRS_MS_TXPWR_MAX_CCH

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. It is broadcast to an MS through
system packet messages on PBCCH by BTS. Network controls the
MS transmit power during communication between MS with BTS. MS
power control is implemented with power control commands. MS output
transmit power must meet the radio network standard. If an MS cannot
output this power because of low power level, it gives an power closest
to the standard.
This parameter is also used for MS cell selection and re-selection,
involved in the calculation of C1 and C2 values.
Refer to appendix C, for the maximum power before MS receives the
power control information.
The setting for this parameter should follow this principle: guarantee a
certain success rate of MS access at the cell edge while decreasing the
access level of MS as much as possible. Generally, it is recommended
to set this parameter to 5 (for GSM900MS) and 2 (for GSM1800MS).
After the parameter is set, make a dial test at the cell boundary. Test the
success rate of MS access and access time under different parameter
settings to determine whether to increase or decrease the value of the

Description

parameter.
3-38

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

This parameter indicates the parameter used during reselection in


transmission state.
Managed Object

Cell

Value Range and Step

0..31

Unit

None

Default Value

Default Value

The parameter impacts the PBCCH channel configuration, and C31 and

Configuration Reason

C32 reselection standards. It is not recommended to be used.


If this parameter value is too high, the MS close to BTS will disturb the
adjacent channel; if the value is too low, the success rate of MS access
at the edge of cell will be low.
The setting for this parameter should follow this principle: guarantee a
certain success rate of MS access at the cell edge while decreasing the

Configuration Rule and

access level of MS as much as possible. Obviously, the coverage area

Adjustment Suggestion

increases with the uplift of MS output power. It is recommended to set


this parameter 5 (for GSM900MS) and 0 (for GSM1800MS).
After the parameter is set, make a dial test at the cell boundary. Test the
success rate of MS access and access time under different parameter
settings to determine whether to increase or decrease the value of the
parameter.

Change Mode

Offline

Related features

ZGB-02-02-006 GPRS MS Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->GERAN External Cell


Config->GPRS Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3-39
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3.2 UTRAN External Cell Parameters


3.2.1 Basic property
3.2.1.1 User Label
Full Name

User Label

Abbreviation

UserLabel

3GPP Name

None

3GPP Reference

None

Description

This parameter means the UTRAN external cell name for users to identify.

Managed Object
Value Range and
Step

Cell
Character string with the maximum length of 40.

Unit

None

Default Value

None

Default Value
Configuration
Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->External Cell Config->UTRAN External Cell Con-

OMC Access Path

fig->Basic property

Parameter Modifying
Version

None

3-40
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Parameter Modifying
Detail

None

3.2.1.2 External UTRAN ID (Ec3GID)


Full Name

External UTRAN ID

Abbreviation

Ec3GID

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the external cell number of the UTRAN.

Managed Object

Cell

Value Range and Step

1..65535; step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

None (Configured according to the cell type, TD cell or W cell, affecting

Adjustment Suggestion

the execution of algorithms in 2-3G handovers)

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config->Basic property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3-41
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3.2.1.3 UTRAN cell type (CellType3G)


Full Name

UTRAN cell type

Abbreviation

CellType3G

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the duplex mode of the local UTRAN cell

Managed Object

Cell

Value Range and Step

FDD, TDD

Unit

None

Default Value

FDD

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

[Cell]Arfcn3G
[Cell]ScCodeCellPara
[Cell]BandWidth3G
[Cell]SyncCaseTSTD
This parameter has effect on the value range of ScCodeCellPara, and

Relationship

on the value range and default value of Arfcn3G.


When you select "TDD", two configurable parameters, BandWidth3G
and SyncCaseTSTD, will appear on the interface.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Config->Basic property
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3-42
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

3.2.1.4 MCC (MCC)


Full Name

MCC

Abbreviation

MCC

3GPP Name

None

3GPP Reference

None
A Mobile Country Code (MCC) consists of three decimal digits and is used

Description

to uniquely identify the country where a mobile user (or system) belongs.

Managed Object

Cell

Value Range and Step

0..999; Step: 1

Unit

None

Default Value

460

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config->Basic property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.2.1.5 MNC (MNC)


Full Name

MNC

Abbreviation

MNC

3-43
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

None

3GPP Reference

None
A Mobile Network Code (MNC) consists of three decimal digits and is
used to uniquely identify a specific GSM PLMN in a country (depending

Description

on MCC).

Managed Object

Cell
If MNC3Digits is set to "2 digits", the value range will be 0 to 99.

Value Range and Step

If MNC3Digits is set to "3 digits", the value range will be 0 to 999.

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

[BSC]MNC3Digits
If MNC3Digits is set to "2 digits", the MNC can only be two digits long. If

Relationship

MNC3Digits is set to "3 digits", the MCN can only be three digits long.
If MNC3Digits is set to "2 or 3 digits", the MNC can be two or three
digits long.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config->Basic property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.2.1.6 UTRAN cell frequency (Arfcn3G)


Full Name

UTRAN cell frequency

3-44
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Abbreviation

Arfcn3G

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the frequency range of the adjacent UTRAN cell.

Managed Object

Cell
When CellType3G is set to"FDD", the value range will be 412 to 10838.
When CellType3G is set to "TDD" and BandWidth3G is set to "0(3.84
Mcps)", the value range will be 2112 to 13088.
When CellType3G is set to "TDD" and BandWidth3G is set to "1(1.28

Value Range and Step

Mcps)", the value range will be 9254 to 13096.

Unit

None
When CellType3G is set to"FDD", the default value will be 412.
When CellType3G is set to "TDD" and BandWidth3G is set to "0(3.84
Mcps)", the default value will be 2112.
When CellType3G is set to "TDD" and BandWidth3G is set to "1(1.28

Default Value

Mcps)", the value range will be 9254.

Default Value

This parameter should be configured according to radio parameter

Configuration Reason

planning.

Configuration Rule and

This parameter should be configured according to radio parameter

Adjustment Suggestion

planning.

Change Mode

Offline

Related features

ZGO-02-03-009 GSM/WCDMA Interworking Phase II

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config->Basic property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3-45
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3.2.1.7 LAC (LAC)


Full Name

LAC

Abbreviation

LAC

3GPP Name

None

3GPP Reference

None
Each PLMN is divided into many location areas to locate mobile stations.
Location area codes (LACs) are used to identify different location
areas. LAC is part of LAI (LAI = MCC + MNC + LAC). One location
area contains multiple cells.

Description

This parameter must be consistent with that configured at the CN side.

Managed Object

Cell
1..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config->Basic property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3-46
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

3.2.1.8 RNC ID (RNC_ID)


Full Name

RNC ID

Abbreviation

RNC_ID

3GPP Name

None

3GPP Reference

None
This parameter indicates the ID of the RNC to which the adjacent UTRAN

Description

cell belongs.

Managed Object

Cell
0..4095

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

This parameter should be configured according to radio parameter

Configuration Reason

planning.

Configuration Rule and

This parameter should be configured according to radio parameter

Adjustment Suggestion

planning.

Change Mode

Offline

Related features

ZGO-02-03-009 GSM/WCDMA Interworking Phase II

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config->Basic property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.2.1.9 C ID (C_ID)
Full Name

C ID

3-47
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

C_ID

3GPP Name

None

3GPP Reference

None

Description

This parameter is used to identify the adjacent UTRAN cell.

Managed Object

Cell
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

This parameter should be configured according to radio parameter

Configuration Reason

planning.

Configuration Rule and

This parameter should be configured according to radio parameter

Adjustment Suggestion

planning.

Change Mode

Offline

Related features

ZGO-02-03-009 GSM/WCDMA Interworking Phase II

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config->Basic property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.2.1.10 Scrambling code or cell parameter (ScCodeCellPara)


Full Name

Scrambling code or cell parameter

Abbreviation

ScCodeCellPara
Scrambling Code(25.213)

3GPP Name

Cell Parameter(25.213)

3-48
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

3GPP Reference

44.018
FDD: The details of FDD can be found in the protocol 3GPP TS25.213.
ScCodeCellPara is a scrambling code used to distinguish the carriers in
the UTRAN/FDD network. Mobile stations measure the main scrambling
code of the downlink CPICH in a cell for handovers or cell reselections.
The scrambling codes are divided into 512 groups, from group 0 to group
511. Each group has one primary scrambling code and 15 secondary
scrambling codes. 511The 512 primary scrambling codes can be divided
into 64 scrambling code sets, each of which has eight scrabbling codes.
TDD: It is a parameter that describes adjacent cells.
When ScCodeCellPara is set to 65535, all cells with the set frequency

Description

will be measured, regardless of scrambling codes or cell parameters.

Managed Object

External Neighbor Cell


When CellType3G is set to "FDD", this parameter is an FDD scrambling
code and its value range is 0 to 511, and 65535, with a step of 1.
When CellType3G is set to "TDD", this parameter is a TDD cell

Value Range and Step

parameter and its value range is 0 to 127, and 65535, with a step of 1.

Unit

None

Default Value

Default Value
Configuration Reason

This parameter should be set according to adjacent 3G cells.

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to adjacent 3G cells.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config->Basic property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None
3-49

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3.2.1.11 TX diversity indication (DiverSity)


Full Name

TX diversity indication

Abbreviation

DiverSity
Diversity 44.018\

3GPP Name

Diversity TDD(25.224)

3GPP Reference

44.018

Description

This parameter decides whether adjacent UTRAN cells use Tx diversity.

Managed Object

External Neighbor Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

Generally, Tx diversity is not used.

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to adjacent 3G cells.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config->Basic property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.2.1.12 RAC (RAC)


Full Name

RAC

Abbreviation

RAC

3-50
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

3GPP Name

None

3GPP Reference

None
Compared with the GSM system that uses location areas to manage a
group of cells, GPRS divides a location area to several routing areas
that are identified by RAI (MCC + MNC + LAC + RAC). When a mobile
station in attach status carries out a cell reselection, it will initiate a
"Routing Area Update" process if the RAI of the new cell is different from
that of the old cell.
The SGSN has the routing area information of the MSs that are in
standby status. Therefore, when packet data or circuit data is transmitted
in the network, the MSs will be paged in the routing area. .Cross-SGSN
RAI cannot be used.

Description

This parameter must be consistent with that configured at the CN side.

Managed Object

Cell
0..255

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config->Basic property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3-51
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3.2.1.13 UTRAN adjacent cell bandwidth (BandWidth3G)


Full Name

UTRAN adjacent cell bandwidth

Abbreviation

BandWidth3G

3GPP Name

Bandwidth_TDD(25.331)

3GPP Reference

44.018
When CellType3G is set to "TDD", this parameter appears and can be

Description

set, indicating the bandwidth of the selected adjacent UTRAN cell.

Managed Object

External Neighbor Cell

Value Range and Step

1 (1.28 Mcps); 0(3.84 Mcps)

Unit

None

Default Value

1 (1.28 Mcps)

Default Value
Configuration Reason

The value 3.84 Mcps is not used any more.

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to adjacent 3G cells.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config->Basic property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.2.1.14 Apply Sync Case / Apply TSTD (SyncCaseTSTD)


Full Name

Apply Sync Case / Apply TSTD

Abbreviation

SyncCaseTSTD

3-52
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Sync Case TSTD


3GPP Name

(25.304, 25.224)

3GPP Reference

44.018
This parameter decides whether to use SyncCase or TSTD. TSTD refers
to time switched transmit diversity. SyncCase refers to synchronization

Description

mode is not used currently.

Managed Object

External Neighbor Cell


When CellType3G is set to "TDD" and BandWidth3G is set to "1(1.28
Mcps)", this parameter decides whether to use TSTD and its name is
"Apply TSTD". In this case, the value range is Yes and No.
When CellType3G is set to "TDD" and BandWidth3G is set to "0(3.84
Mcps)", this parameter decides whether to use Sync Case and its name

Value Range and Step

is "Apply Sync Case". In this case, the value range is Yes and No.

Unit

None

Default Value

No

Default Value
Configuration Reason

The default value varies with applications.

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to adjacent 3G cells.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config->Basic property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3-53
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3.2.2 Others
3.2.2.1 Report characteristics (ReportType)
Full Name

Report characteristics

Abbreviation

ReportType

3GPP Name

Report characteristics

3GPP Reference

3GPP 25.423 8.5.2


This parameter determines the mode of reporting measurement reports.
The available options are as follows:
1 On Demand
2 Periodic

Description

7 Event E

Managed Object

BSC

Value Range and Step

1: On Demand 2: Period 7: EventE

Unit

None

Default Value

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.
To uninterruptedly reflect the load on the peer end by using the common

Configuration Rule and


Adjustment Suggestion

measurement reporting mode of the Iur-g interface, select "2" (Periodic).


To report measurement reports when certain conditions are met, select
"7" (Event E). To report measurement reports once, select "1" (On
Demand).

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config

Parameter Modifying
Version

iBSCV6.20.710

3-54
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Parameter Modifying
Detail

New

3.2.2.2 Report periodicity unit (RepPeriodUnit)


Full Name

Report periodicity unit

Abbreviation

RepPeriodUnit

3GPP Name

None

3GPP Reference

None
When the common measurement mode is configured to "Periodic", this
parameter determines the unit of reporting interval.
1 10ms

Description

2 1Min

Managed Object

BSC
1: 10ms

Value Range and Step

2: 1Min

Unit

None

Default Value

Default Value
Configuration Reason

In the case of periodic reporting, the unit is second.


Generally, the period is short for periodic reporting, which helps reflect

Configuration Rule and

the load on the peer end in real time. When the requirements on

Adjustment Suggestion

the real-time load on the peer end are relatively low, the unit can be
changed to minute.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config

Parameter Modifying
Version

iBSCV6.20.710
3-55

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

3.2.2.3 Report periodicity value (RepPeriodValue)


Full Name

Report periodicity value

Abbreviation

RepPeriodValue

3GPP Name

Report Periodicity Value

3GPP Reference

3GPP 25.423 9.1.48a


When the common measurement mode is configured to "Periodic", this
parameter determines the reporting interval.
When "RepPeriodUnit" is configured to "1", the step is 10ms and the
value ranges from 1 to 6000.
When "RepPeriodUnit" is configured to "2", the step is 1Min and the

Description

value ranges from 1 to 60.

Managed Object

BSC
When RepPeriodUnit is 1, the step is 10ms and the value range is
1-6000.

Value Range and Step

RepPeriodUnit2, 1Min, 1-60

Unit

None

Default Value

100

Default Value
Configuration Reason

Generally, measurement reports are reported every one second.


To use second or a unit lower than second as the reporting period,

Configuration Rule and


Adjustment Suggestion

configure "RepPeriodUnit" to "1". In this case, the value of this parameter


ranges from 1 to 6000 (10 ms to 60s). To use minute as the reporting
period, configure "RepPeriodUnit" to "2". In this case, the value of this
parameter ranges from 1 to 60 (1 minute to 60 minutes).

Change Mode

Offline

Related features

None

Related Parameters

RepPeriodUnit
When "RepPeriodUnit" is configured to "1", the step is 10ms and the

Relationship

value ranges from 1 to 6000. When "RepPeriodUnit" is configured to "2",


the step is 1 minute and the value ranges from 1 to 60.

Related Interfaces

None

Impact on Equipment

Impact on service

3-56
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

3.2.2.4 Load/RT Load/NRT Load measurement threshold 1 (MeasThr1_0~MeasThr1_2)


Full Name

mLoad/RT Load/NRT Load measurement threshold 1

Abbreviation

MeasThr1_0~MeasThr1_2

3GPP Name

Measurement Threshold 1

3GPP Reference

3GPP 25.423 9.1.39


This parameter determines reporting threshold 1 of event E. The available thresholds for the Iur-g interface are Load, RT Load, and NRT Load.
When the value is higher than this threshold, the system reports measure-

Description

ment reports.

Managed Object

BSC
Load Measurement Threshold 1: 0..100
RT Load Measurement Threshold 1: 0..100

Value Range and Step

NRT Load Measurement Threshold 1: 0..3

Unit

None
Load Measurement Threshold 1: 50
RT Load Measurement Threshold 1: 50

Default Value

NRT Load Measurement Threshold 1: 2

Default Value

It is required to configure this parameter according to the principle that

Configuration Reason

measurement reports are reported if the load exceeds 50%.

Configuration Rule and

To hope that event report is insensitive to load, increase event threshold

Adjustment Suggestion

1. Otherwise, decrease event threshold 1.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

3-57
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

3.2.2.5 Load/RT Load/NRT Load measurement threshold 2 (MeasThr2_0~MeasThr2_2)


Full Name

Load/RT Load/NRT Load measurement threshold 2

Abbreviation

MeasThr2_0~MeasThr2_2

3GPP Name

Measurement Threshold 2

3GPP Reference

3GPP 25.423 9.1.39


This parameter determines reporting threshold 2 of event E. The available thresholds for the Iur-g interface are Load, RT Load, and NRT Load.
When the value is lower than this threshold, the system stops reporting

Description

measurement reports.

Managed Object

BSC
Load Measurement Threshold 1: 0..100
RT Load Measurement Threshold 1: 0..100

Value Range and Step

NRT Load Measurement Threshold 1: 0..3

Unit

None
Load Measurement Threshold 1: 40
RT Load Measurement Threshold 1: 40

Default Value

NRT Load Measurement Threshold 1: 1

Default Value
Configuration Reason

This threshold is lower than event threshold 1.

Configuration Rule and

To hope that event report is insensitive to load, decrease event threshold

Adjustment Suggestion

2. Otherwise, increase event threshold 2.

Change Mode

Offline

Related features

None

Related Parameters

MeasThr1

Relationship

The value is lower than that of MeasThr1.

Related Interfaces

None

3-58
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

3.2.2.6 Measurement hysteresis time (MeasHys,10ms)


Full Name

Measurement hysteresis time

Abbreviation

MeasHys

3GPP Name

Measurement Hysteresis Time

3GPP Reference

3GPP 25.423 9.1.36A


This parameter determines the delay time of reporting based on event
E. The system reports or stops reporting measurement reports after this

Description

delay time when the corresponding conditions are met.

Managed Object

BSC

Value Range and Step

1..6000

Unit

10ms

Default Value

100

Default Value
Configuration Reason

Generally, configure this parameter to 1s.

Configuration Rule and

To hope that the delay time of reporting based on event E is short,

Adjustment Suggestion

decrease this value. Otherwise, increase this value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
3-59

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

3.2.2.7 Event report periodicity (EveRepPeriod,10ms)


Full Name

Event report periodicity

Abbreviation

EveRepPeriod

3GPP Name

Report Periodicity

3GPP Reference

3GPP 25.423 9.1.48A


This parameter determines the period of reporting based on event E when

Description

the event reporting conditions are met.

Managed Object

BSC

Value Range and Step

1..6000

Unit

10ms

Default Value

100

Default Value
Configuration Reason

Generally, measurement reports are reported every one second.

Configuration Rule and


Adjustment Suggestion

It is required to configure this parameter as required.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config

3-60
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

3.2.2.8 Measurement timer (MeasTimer,10ms)


Full Name

Measurement timer

Abbreviation

MeasTimer

3GPP Name

None

3GPP Reference

None
This parameter is a protection timer of measurement instances. This timer
is enabled when the system waits for responses of initialization or measurement report status. This timer restarts if no response or report is
received after the timeout time. In addition, this timer is disabled before

Description

instances are released.

Managed Object

BSC

Value Range and Step

1..65535

Unit

10ms

Default Value

500

Default Value
Configuration Reason

Generally, configure this parameter to 5s.

Configuration Rule and

This parameter is an internal parameter, and usually requires no

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config

Parameter Modifying
Version

iBSCV6.20.710
3-61

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

3.2.2.9 Measurement max retry number (MeasMaxRetryNum)


Full Name

Measurement max retry number

Abbreviation

MeasMaxRetryNum

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum retry times when no response is
received after the timeout time configured for the protection timer of measurement instances. Alternatively, this parameter determines the maxi-

Description

mum restart times of the timer when no measurement report is received.

Managed Object

BSC

Value Range and Step

[1,2,3]

Unit

times

Default Value

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.

Configuration Rule and

This parameter is an internal parameter, and usually requires no

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New
3-62

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

3.2.2.10 ExternalUtranCell (ParaCtrlSwitch)


Full Name

ExternalUtranCell

Abbreviation

ParaCtrlSwitch

3GPP Name

None

3GPP Reference

None
This parameter determines whether to use cell parameters or BSC global

Description

parameters. 1-BSC global parameters; 0-Cell parameters

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value

By default, the system uses BSC global parameters. Cell parameters

Configuration Reason

are currently not supported.

Configuration Rule and

Cell parameters are currently not supported and no adjustment is

Adjustment Suggestion

required.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Config
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

None

3.2.2.11 Information report type (InfoReportType)


Full Name

Information report type

Abbreviation

InfoReportType
3-63

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

None

3GPP Reference

None
This parameter determines the information reporting mode. 1: reported

Description

immediately; 3: reported after being modified

Managed Object

BSC
1: Ondemand

Value Range and Step

3: Periodic

Unit

None

Default Value

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.

Configuration Rule and

To hope that the information such as load on the peer end is reported

Adjustment Suggestion

after being modified, configure this parameter to 3.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell


Config

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

3.2.2.12 Measurement type (MeasType)


Full Name

Measurement type

Abbreviation

MeasType

3GPP Name

None

3GPP Reference

None

3-64
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

This parameter determines the common measurement type. 2: Load; 6:


Description

RT Load; 7: NRT Load

Managed Object

BSC

Value Range and Step

2: Load 6: RT Load 7: NRT Load

Unit

None

Default Value

Default Value

This interface is designed for China Mobile only. Therefore, configure

Configuration Reason

this parameter according to the requirements of China Mobile.

Configuration Rule and

According to the requirements of China Mobile, this parameter is not

Adjustment Suggestion

modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->External Cell Config->UTRAN External Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Config
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

3.3 LTE External Cell Parameters


3.3.1 User label (UserLabel)
Full Name

User label

Abbreviation

UserLabel

3GPP Name

None

3GPP Reference

None

Description

This parameter facilitates subscribers to identify a cell name.

3-65
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell

Value Range and Step

A string with 40 characters at most

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->External Cell Config->LTE External Cell Config

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.3.2 LTE CELL Identification (LTECELLID)


Full Name

LTE CELL Identification

Abbreviation

LTECELLID

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the ID of an external LTE cell.

Managed Object

Cell

Value Range and Step

1..65535

Unit

None

Default Value

None

3-66
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->External Cell Config->LTE External Cell Config

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.3.3 MCC (MCC)


Full Name

MCC

Abbreviation

MCC

3GPP Name

None

3GPP Reference

None
The Mobile Country Code (MCC) consists of three decimal digits. It
uniquely identifies the country to which a mobile subscriber (or system)

Description

belongs.

Managed Object

Cell

Value Range and Step

0..999

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.
3-67

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->External Cell Config->LTE External Cell Config

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.3.4 MNC (MNC)


Full Name

MNC

Abbreviation

MNC

3GPP Name

None

3GPP Reference

None
A Mobile Network Code (MNC) consists of three decimal digits and is
used to uniquely identify a specific GSM PLMN in a country (depending

Description

on MCC).

Managed Object

Cell

Value Range and Step

None

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

3-68
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->External Cell Config->LTE External Cell Config

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.3.5 LTE CELL Identification (ENBID)


Full Name

LTE CELL Identification

Abbreviation

ENBID

3GPP Name

None

3GPP Reference

None

Description

This parameter determines the ID of an LTE cell.

Managed Object

Cell

Value Range and Step

0..1048575

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
3-69

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->External Cell Config->LTE External Cell Config

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.3.6 LTE CELL TYPE (CellTypeLTE)


Full Name

LTE CELL TYPE

Abbreviation

CellTypeLTE

3GPP Name

None

3GPP Reference

None

Description

TDD.

Managed Object

Cell

This parameter determines the type of an LTE cell, including FDD and

0..1
0: FDD
Value Range and Step

1: TDD

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->External Cell Config->LTE External Cell Config

3-70
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.3.7 Tracking area code (TAC)


Full Name

Tracking area code

Abbreviation

TAC

3GPP Name

None

3GPP Reference

None

Description

This parameter determines the ID of a trace cell.

Managed Object

Cell

Value Range and Step

0..65535

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->External Cell Config->LTE External Cell Config

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3-71
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3.3.8 Physical layer cell identity of LTE CELL (PCID)


Full Name

Physical layer cell identity of LTE CELL

Abbreviation

PCID

3GPP Name

PCID

3GPP Reference

3GPP TS 44018 V8.9.0

Description

This parameter determines the physical ID of an LTE cell.

Managed Object

Cell

Value Range and Step

0..503

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->External Cell Config->LTE External Cell Config

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.3.9 The attribute of LTE NodeB (ENBInd)


Full Name

The attribute of LTE NodeB

Abbreviation

ENBInd

3GPP Name

None

3GPP Reference

None
3-72

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

Description

This parameter determines the attribute of an LTE NodeB.

Managed Object

Cell
0..1
0: Macro eNB

Value Range and Step

1: Home eNB

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->External Cell Config->LTE External Cell Config

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.3.10 specified EARFCN of E-UTRAN cells (ArfcnLTE)


Full Name

specified EARFCN of E-UTRAN cells

Abbreviation

ArfcnLTE

3GPP Name

EARFCN

3GPP Reference

3GPP TS 44018 V8.9.0

Description

This parameter determines the frequency of an adjacent LTE cell.

Managed Object

Cell

Value Range and Step

0..65535

3-73
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->External Cell Config->LTE External Cell Config

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3.3.11 the minimum value of the channel bandwidth


(MeasureBandwidth)
Full Name

the minimum value of the channel bandwidth

Abbreviation

MeasureBandwidth

3GPP Name

None

3GPP Reference

None
This parameter determines the minimum bandwidth for the channel of an

Description

adjacent LTE cell.

Managed Object

Cell

3-74
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 3 External Cell Parameters

0..7
0: NRB = 6
1: NRB = 15
2: NRB = 25
3: NRB = 50
4: NRB = 75
5: NRB = 100
Value Range and Step

6-7: reserved

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->External Cell Config->LTE External Cell Config

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

3-75
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This page intentionally left blank.

3-76
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4

Cell Parameters
Table of Contents
Basic Parameters 1 ....................................................................................................4-1
Basic Parameters 2 ..................................................................................................4-30
Basic Parameters 3 ..................................................................................................4-70
Optional Parameters ..............................................................................................4-103
Cell Selection Parameters ......................................................................................4-133
Service Process Additional Parameters..................................................................4-162
System Parameters................................................................................................4-184
AMR Half Method Parameters................................................................................4-207
AMR Full Method Parameters ................................................................................4-215
Other Parameters...................................................................................................4-223
GPRS Basic Parameters ........................................................................................4-245
GPRS Other Parameters 1 .....................................................................................4-252
GPRS Other Parameters 2 .....................................................................................4-266
GPRS Other Parameters 3 .....................................................................................4-300
GPRS Cell Options Parameters .............................................................................4-358
GPRS NC Survey Parameters................................................................................4-376
GPRS Power Control Parameters ..........................................................................4-391
GPRS Cell Reselection Parameters .......................................................................4-398
GPRS Channel Parameters....................................................................................4-434
PS Handover Parameters.......................................................................................4-460
EDGE Parameters..................................................................................................4-469
AMR-WB Parameter...............................................................................................4-497
VAMOS Parameter.................................................................................................4-499
Cell Power Parameter ............................................................................................4-529
GPRS Resource Control By Service.......................................................................4-556

4.1 Basic Parameters 1


4.1.1 User Label
Full Name

User Label

Abbreviation

UserLabel

3GPP Name

None

3GPP Reference

None
4-1

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Description

This parameter means the cell name that is easy to be recognized by users.

Managed Object

Cell

Value Range and


Step

Character string with the maximum length of 40.

Unit

None

Default Value

None

Default Value
Configuration
Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.2 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None

Description
Managed Object

This parameter means the site ID. It cannot be modified.


Consistent with managed element ID for SDR.
Site
4-2

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Value Range and Step

1 ~ 1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path


Parameter

Modifying

Version
Parameter

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters 1

None
Modifying

Detail

None

(BSCID)
4.1.3 BSC
Full Name

BSC ID

Abbreviation

BSCID

3GPP Name

None

3GPP Reference

None

Description
Managed Object
Value Range and
Step

BSC ID cannot be modified. By default, the value is the same with that
of subnetwork ID.
Cell
1 ~ 4095

Unit

None

Default Value

None

4-3
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration
Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.4 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the serial number of this cell.

Managed Object

Cell

4-4
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

1..108
The maximum value of BtsId for each site type is as follows:
OB06: 3
BS20: 3
BS21: 3
BS21V20: 3
BS30: 3
BS30V12: 3
B8112: 6
M8202: 6
M8206: 6
B8018: 6
S8001: 1
Value Range and Step

SDR: 108

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-5
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Note:
For the meaning of Site ID and BTS ID on other interfaces, please refer to the description
here.

4.1.5 Cell Type (CellType)


Full Name

Cell Type

Abbreviation

CellType

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the type of this cell.

Managed Object

Cell
0..4
0: umbrella cell
1: macro-cell
2: micro-cell
3: pico-cell

Value Range and Step

4: extended cell

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-6
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.6 MCC (MCC)


Full Name

MCC

Abbreviation

MCC

3GPP Name

None

3GPP Reference

None
A Mobile Country Code (MCC) is used to uniquely identify the country
where a mobile user (or system) belongs. MCCs are allocated interna-

Description

tionally. China's is 460.

Managed Object

Cell

Value Range and Step

It depends on the parameter MCC in BSC global resource parameters.

Unit

None

Default Value

It depends on the parameter MCC in BSC global resource parameters.

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1
4-7

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.7 MNC (MNC)


Full Name

MNC

Abbreviation

MNC

3GPP Name

None

3GPP Reference

None
A Mobile Network Code (MNC) is used to uniquely identify a specific
PLMN in a country (depending on MCC). For example, the code "07" rep-

Description

resents the PLMN of China Mobile.

Managed Object

Cell

Value Range and Step

It depends on the parameter MNC in BSC global resource parameters.

Unit

None

Default Value

It depends on the parameter MNC in BSC global resource parameters.

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None
If MNC3Digits is set to "2 digits", the MNC can only be two digits long. If

Relationship

MNC3Digits is set to "3 digits", the MCN can only be three digits long.
If MNC3Digits is set to "2 or 3 digits", the MNC can be two or three
digits long.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


1
4-8
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.8 LAC (LAC)


Full Name

LAC

Abbreviation

LAC

3GPP Name

None

3GPP Reference

None
Each GSM PLMN is divided into many location areas to locate mobile
stations. Location area codes (LACs) are used to identify different
location areas. LAC is part of LAI (LAI = MCC + MNC + LAC). One
location area contains multiple cells.

Description

This parameter must be consistent with that configured at the CN side.

Managed Object

Cell
1..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1
4-9

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.9 CI (CI)
Full Name

CI

Abbreviation

CI

3GPP Name

None

3GPP Reference

None
Network operators must allocate a unique code to each cell in a location

Description

area to identify every cell.

Managed Object

Cell
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

4-10
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

None

4.1.10 NCC (NCC)


Full Name

NCC

Abbreviation

NCC

3GPP Name

None

3GPP Reference

None
NCC is one of the composition parts of Base Station ID Code (BSIC)
(BSIC = NCC + BCC), which is used to enable the MS to distinguish adjacent and different GSM PLMN cells. Usually adjacent operators shall
have different NCCs. The parameter related to NCC is "NccPermitted" of
the cell. By prohibiting MS to report related NCC in the cell, MS is prohibited to measure the cell information of the related operators. Actually,
NCC occupies three bits. NCC is one of the network identification param-

Description

eters.

Managed Object

Cell
0..7

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-11
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.11 BCC (BCC)


Full Name

BCC

Abbreviation

BCC

3GPP Name

None

3GPP Reference

None
BCC is one of the composition parts of Base Station ID Code (BSIC) (BSIC
= NCC + BCC). Usually BCC is used to enable MS to distinguish adjacent
cells with the same BCCH carrier frequency and belonging to the same
GSM PLMN. In addition, the GSM specifications stipulate that the TSC
(Training Sequence Code) of the broadcast control channel of a cell shall
be equal to the cell BCC. BCC occupies three bits. BCC is one of the

Description

network identification parameters.

Managed Object

Cell
0..7

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

4-12
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.12 Frequency band (FreqBand)


Full Name

Frequency band

Abbreviation

FreqBand

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the supported frequency band

Managed Object

Cell
0: PGSM (1..124);
1: EGSM (0..124, 975..1023);
2: DCS1800 (512..885);
4: GSM1900 (512..810);

Value Range and Step

7: GSM850 (128..251)

Unit

None

Default Value

0: PGSM

Default Value
Configuration Reason

Depends on the actual configuration.

Configuration Rule and


Adjustment Suggestion

It is configured as required.

Change Mode

Offline

Related features

ZGO-05-02-002 EGSM Frequency Band Support

Related Parameters

[BSC]FuncExt
[CellTrx]Frequency
The value of DCS1800/PCS1900 supported (FuncExt) has influence on

Relationship

the value range of this parameter.


This parameter value has influence on the value range of CaArfcnList.

Related Interfaces

None
4-13

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.13 Subcell used (SubCellUsed)


Full Name

Subcell used

Abbreviation

SubCellUsed

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates whether this cell uses the subcell switch.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.

Configuration Rule and


Adjustment Suggestion

Enabled when a subcell needs to be configured.

Change Mode

Offline

Related features

ZGO-04-02-005 Co-BCCH

Related Parameters

[Cell]SubFreqBand
[Cell]SubCellId

Relationship

When this parameter is Yes, SubFreqBand parameter can be set.


This parameter value has influence on the value range of SubCellId.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
4-14

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.14 Frequency Band of subcell (SubFreqBand)


Full Name

Frequency Band of subcell

Abbreviation

SubFreqBand

3GPP Name

None

3GPP Reference

None

Description

This parameter sets the frequency band of subCell.

Managed Object

Cell
When the value of DCS1800/PCS1900 supported (FuncExt) is
DCS1800, the value range is GSM900, EXT900, DCS1800, GSM850;
When the value of DCS1800/PCS1900 supported (FuncExt) is

Value Range and Step

PCS1900, it value range is GSM900, EXT900, PCS1900, GSM850;

Unit

None

Default Value

GSM900

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

ZGO-04-02-005 Co-BCCH

Related Parameters

[Cell]SubCellUsed
[BSC]FuncExt
If "Subcell used" is set to "Yes", this parameter can be configurable.

Relationship

The value of DCS1800/PCS1900 supported (FuncExt) has influence on


the value range of this parameter.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
4-15

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.15 ARFCN list (CaArfcnList)


Full Name

ARFCN list

Abbreviation

CaArfcnList

3GPP Name

44.018, Cell Channel Description

3GPP Reference

None
This parameter provides a list of Absolute Radio Frequency Channel

Description

Numbers (ARFCNs).

Managed Object

Cell
The value range of each ARFCN is the same as BCCH. The ARFCN list

Value Range and Step

contains the channel numbers configured for all TRXs.

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and

The ARFCN list is automatically generated by the system according to

Adjustment Suggestion

the channel numbers used in the cell.

Change Mode

Offline

Related features

None

Related Parameters

None
The ARFCNs in subcell 1 and subcell 2 should comply with the following
constraints:
1) In the case of PGSM900 system,
the CA list contains 124 ARFCNs at most. (A cell has 64 ARFCNs at

Relationship

most.)
2) In the case of EGSM or DCS1800 system,
if the difference between the maximum ARFCN and the minimum one
is less than 112, the list can contain 112 ARFCNs at most. (A cell has
64 ARFCNs at most.)

4-16
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

if the difference between the maximum ARFCN and the minimum one is
less than 128, the list can contain 29 ARFCNs at most.
if the difference between the maximum ARFCN and the minimum one is
less than 256, the list can contain 22 ARFCNs at most.
if the difference between the maximum ARFCN and the minimum one is
less than 512, the list can contain 18 ARFCNs at most.
if the difference between the maximum ARFCN and the minimum one
is equal to or larger than 512, the list can contain 17 ARFCNs at most
when 0 is included, or 16 ARFCNs at most when 0 is not included.
Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.16 GPRS service support (PsSupport)


Full Name

GPRS service support

Abbreviation

PsSupport

3GPP Name

None

3GPP Reference

None
This parameter indicates whether this cell supports GPRS (EDGE) service.If "GPRS supported" or "EDGE supported" is selected, relevant sub-

Description

pages may appear on the interface.

Managed Object

Cell
GPRS is not supported, GPRS is supported, EDGE is supported, EG-

Value Range and Step

PRS2-A is not supported

Unit

None

Default Value

GPRS is not supported.

Default Value
Configuration Reason

The default value is dependent upon the network requirement.

4-17
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

For the cell which does not support PS service, it is set as: Don't support
GPRS;
For the cell which only supports the GPRS service, it is set as: Support
Configuration Rule and
Adjustment Suggestion

GPRS;
For the cell which supports the GPRS and EDGE services, it is set as:
Support EDGE;
For the cell which supports the GPRS , EDGE and EDGE2 services, it is
set as: Support EDGE2.
The V2 80W BTS only supports CS1/2.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.17 Dynamic HR support indication (DynaHREnable)


Full Name

Dynamic HR support indication

Abbreviation

DynaHREnable

3GPP Name

None

3GPP Reference

None
This parameter indicates whether this cell supports dynamic HR. This feature means the system can allocate full rate or half rate channel for the
MS based on cell traffic while the network is allocating channels for the
MS.If the cell channels are congested, the system can allocate half rate
channels, so the period of cell congestion at peak time decreases to the

Description

minimum extent.

4-18
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

This switch can be enabled to expand cell capacity when subscribers in

Adjustment Suggestion

the cell reach or exceed the channel capacity in it.

Change Mode

Offline

Related features

ZGO-03-02-005 Dynamic Half Rate Allocation

Related Parameters

[Cell]UseCellDynHRPara
[BSC]DynaHREnable
When this parameter (dynamic HR support indication) is "Yes", the

Relationship

parameter (use cell dynamic HR parameter) can be configured. Full rate


channels can be converted to half rate channel till BSC and cell enables
dynamic HR functions simultaneously.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.18 Dynamic HR channel allocation algorithm (DHRAlgrithm)


Full Name

Dynamic HR channel allocation algorithm

Abbreviation

DHRAlgrithm

3GPP Name

None

3GPP Reference

None

4-19
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the calculation method of dynamic HR cells in


busy time.
This parameter controls the calculation method of cell busyness in the
dynamic HR function. If the cell is configured with dynamic channels for
PS service, the channels are converted to dynamic PS channels. When
the CS service and the PS service are taken into consideration, the
system considers that the dynamic PS channels are occupied. If cell
busyness is high, the cell will allocate dynamic HR channels and then
preempt dynamic PS channels. When only the CS service is taken into
consideration, if cell busyness is high and FR channels are insufficient,
Description

the cell will preempt PS channels and then allocate HR channels.

Managed Object

Cell

Value Range and Step

1: Consider CS services only

Unit

None

Default Value

Default Value

Usually, the system considers that a dynamic channel is occupied when

Configuration Reason

being used for the PS service.

0: Consider CS and PS services

Operators hope that the CS service is prior to preempt PS channels and


then allocates dynamic HR channels. This can increase the proportion of
full rate subscribers. If the performance of PS service can be degraded,
Configuration Rule and

this parameter can be configured to 1, that is, only the CS service is

Adjustment Suggestion

taken into consideration.


If operators hope to meet the capacity of CS service and the performance
of PS service, this parameter can be configured to 0, that is, the CS
service and PS service are both taken into consideration.

Change Mode

Offline

Related features

ZGO-03-02-005 Dynamic Half Rate Allocation

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

iBSCV6.20.710

4-20
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

New

4.1.19 CBC support (SmsCbUsed)


Full Name

CBC support

Abbreviation

SmsCbUsed

3GPP Name

None

3GPP Reference

None
CBC service is an important service provided by mobile communication
system, mainly used to distribute information to the mobile subscribers
within certain geographical location area. The difference from P2P sms
service contains: receiver for P2P sms is a specific mobile subscriber,
but receiver for CBC is all mobile subscribers within certain area,
including external subscribers roaming in this area.
This parameter identifies whether this cell supports the function of cell

Description

broadcasting short message.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.

Configuration Rule and


Adjustment Suggestion

Whether to enable this function depends on the needs of operators.

Change Mode

Offline

Related features

None

Related Parameters

[CellTs]TS Channel Combination


If "CBC Supported (SmsCbUsed)" is No, that is, CBC is not supported,
the system automatically finds all time slot channel combinations in the
cell. If CBC channel exists, it is changed to SDCCH. SmsCbUsed

Relationship

If "CBC Supported (SmsCbUsed)" is 'Yes', that is, CBC is supported,


the system automatically finds all time slot channel combinations in
the cell. If a non-BCCH channel is found for a carrier, it is changed to
SDCCH+CBCH.

Related Interfaces

None

4-21
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.20 Threshold for TRX switched from FR to HR (HRThs)


Full Name

Threshold for TRX switched from FR to HR

Abbreviation

HRThs

3GPP Name

None

3GPP Reference

None
When BSC and cell enables dynamic HR functions, and percentage of
TCHF channel used in the cell (the numerator: "TCHF channels occupied + TCHH channel occupied" / "2 + non-blocked static PD channel +
busy dynamic PD channel", the denominator: "all available TCH/H/2" +
"available dynamic and static PDCH channels in current status") exceeds

Description

this threshold, convert TCH/F -> TCH/H.

Managed Object

Cell
1..100

Value Range and Step

Step: 1

Unit

Default Value

60

Default Value
Configuration Reason

When channel occupation rate reaches to 60%, the cell is regarded


as busy, dynamic HR allocation can be performed, so as to expand
cell capacity.

Configuration Rule and

This parameter is appropriately set according to the actual traffic. In the

Adjustment Suggestion

non-congestion status, HR service should not be used.

Change Mode

Offline

Related features

ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters

[Cell]AMRHRThs

4-22
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Relationship

HRThsis greater than or equal to AmrHRThs.

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.21 PS busy threshold (Info_1_16)


Full Name

PS busy threshold

Abbreviation

Info_1_16

3GPP Name

None

3GPP Reference

None
If the cell busyness is greater than this threshold, a maximum of one
dynamic TCHF channel of new PS services is allowed to be converted
into PD. Cell busyness is calculated in accordance with the formula: the
numerator: "TCHF channels occupied + TCHH channel occupied" / "2
+ non-blocked static PD channel + busy dynamic PD channel", the denominator: "all available TCH/H/2" + "available dynamic and static PDCH

Description

channels in current status" ).

Managed Object

Cell
1..100

Value Range and Step

Step: 1

Unit

Default Value

80

Default Value

If over 80% of the channels are occupied, the cell has large traffic. In

Configuration Reason

this case, it is recommended not to expand PS channels.

Configuration Rule and

The smaller the value is, the more the expansion of PS services in the

Adjustment Suggestion

cell is limited.

Change Mode

Offline

Related features

None
4-23

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


1
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.22 Use cell AMR parameter (UseCellAMRParam)


Full Name

Use cell AMR parameter

Abbreviation

UseCellAMRParam

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether the AMR parameters of the cell are
enabled.
If no, the AMR parameters set in the BSC are preferred.

Description

If yes, the AMR parameters of the cell are preferred.

Managed Object

Cell

Value Range and Step

No, Yes

Unit

None

Default Value

No

Default Value

In most cases, the AMR parameters can be set in a unified manner in

Configuration Reason

the BSC for convenient configuration.

Configuration Rule and

Enable this switch if you want to set the AMR parameter depending

Adjustment Suggestion

on the characteristics of the cell.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

None

4-24
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.23 Support AMR-WB (SUPPORTAMRWB)


Full Name

Support AMR-WB

Abbreviation

SUPPORTAMRWB

3GPP Name

None

3GPP Reference

None

Description

0: No; 1: Yes

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: not support

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be configured according to the actual carrier.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

4-25
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.24 Support CS paging prefer PS Assignment (CsPagingPrefer)


Full Name

Support CS paging prefer PS Assignment

Abbreviation

CsPagingPrefer

3GPP Name

Null

3GPP Reference

Null
The parameter determines whether to support the priority of CS paging

Description

higher than that of PS assignment.

Managed Object

CELL
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

Not a basic function, disabled by default.


The base station monitors the occupation of the paging group queue.
When the occupation reaches a percentage (80%), the base station

Configuration Rule and

reports a paging overload message, and checks whether the uplink

Adjustment Suggestion

CCCH request is used for packet services. If yes, the base station
discards the message. The iBSC operates with the base station in
implementing related configurations and counting functions.

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

4-26
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

4.1.25 Common control channel configuration (CcchConf)


Full Name

Common control channel configuration

Abbreviation

CcchConf

3GPP Name

CCCH-CONF

3GPP Reference

3GPP TS 44.018
The common control channel configuration parameter is one of the
system control parameters. In GSM system, CCCH includes Access
Grant Channel (AGCH) and Paging Channel (PCH). It is used to send
access granting (instant assignment) message and paging message.
In each cell, all service channels share CCCH. According to the
configuration of the service channel in the cell and the traffic mode of the
cell, CCCH can be one or more than one physical channel, and CCCH
can share the same physical channel with SDCCH.
The combination mode of the common control channel in a cell
depends on the CCCH configuration parameter and it should be
consistent with the actual configuration of cell CCH. It could be
observed from this parameter: BS_CC_CHANS (Number of CCCH);
BS_CCCH_SDCCH_COMB (combined with SDCCH or not).
This parameter is broadcast to all MSs in a cell through message

Description

RIL3_RR SYSTEM INFORMATION TYPE3.

Managed Object

Cell

4-27
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0: A basic physical channel used by CCCH . It is not used together


with SDCCH;
1: A basic physical channel used by CCCH. It is used together with
SDCCH;
2: Two basic physical channels used by CCCH. It is not used together
with SDCCH;
4: Three basic physical channels used by CCCH. It is not used together
with SDCCH;
6: Four basic physical channels used by CCCH. It is not used by
SDCCH.
Value Range and Step

Other values: Reserved

Unit

None
0: A basic physical channel used by CCCH . It is not used together with

Default Value

SDCCH;

Default Value

In most cases there are more than two carrier frequencies in a cell. A

Configuration Reason

single SDCCH channel is needed.


The setting of this parameter depends on the traffic load of the location
area that the cell resides. 0 can be the default value (must be consistent
with the configurations of the public control channels). It is recommended

Configuration Rule and

that this value should be identical for the cells in the same local area.

Adjustment Suggestion

, TRX12,
SDCCH; TRX
34,
SDCCH.TRX4, .

Change Mode

Offline

Related features

ZGB-03-02-001 Support of SDCCH/4 and SDCCH/8

Related Parameters

[CellTs]TS Channel Combination


If CcchConf is configured as "CCCH uses one physical channel,
combined with SDCCH", then in the channel parameters, channel
combination of timeslot 0 must be one of the following two combinations:
"BCCH+SDCCH/4" and "BCCH+SDCCH/4+CBCH".
When CcchConf is configured as "CCCH uses one physical channel,
not combined with SDCCH", then in the channel parameters, channel
combination of timeslot 0 must be one of the following two combinations:

Relationship

"FCCH+SCH+BCCH+CCCH" and "BCCH+CCCH".


When CcchConf is configured as "CCCH uses two physical channel,
not combined with SDCCH", then in the channel parameters, channel
combination of timeslot 0 and timeslot 2 is one of the following two
combinations: "FCCH+SCH+BCCH+CCCH" and "BCCH+CCCH".
When CcchConf is configured as "CCCH uses three physical channel,
not combined with SDCCH", then in the channel parameters, channel

4-28
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

combination of timeslot 0, 2, and 4 is one of the following two


combinations: 'FCCH+SCH+BCCH+CCCH' and 'BCCH+CCCH'.
When CcchConf is configured as "CCCH uses four physical channel,
not combined with SDCCH", then in the channel parameters, channel
combination of timeslot 0, 2, 4, and 6 is one of the following two
combinations: "FCCH+SCH+BCCH+CCCH" and "BCCH+CCCH".
Related Interfaces

Abis, Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.1.26 Template file


Full Name

Template file

Abbreviation

None

3GPP Name

None

3GPP Reference

None
Click the Select button, a window pops up. Select the template file in local
path.

Description

Click the Clear button to clear selected template files.

Managed Object

Cell

Value Range and Step

Local files

Unit

None

Default Value

None

Default Value

None

Default Value
Configuration Reason

None

Change Mode

Offline

Related Features

None

4-29
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2 Basic Parameters 2


4.2.1 TA Max (TaMax)
Full Name

TA Max

Abbreviation

TaMax

3GPP Name

None

3GPP Reference

None
This parameter represents the maximum TA supported by extended carrier frequency. It defines the cell coverage capability. The users with

Description

values that exceed TaMax cannot access or will be dropped.

Managed Object

Cell
When "Cell Type (CellType)" is non-extended, the value range is 0..63;
Step: 1
When "Cell Type (CellType)" is extended, the value range is 0..219;

Value Range and Step

Step: 1

Unit

None
When "Cell Type (CellType)" is non-extended, the default value is 63;

Default Value

When "Cell Type (CellType)" is extended, the value range is 219;

Default Value
Configuration Reason

Common cell by default

4-30
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Configuration Rule and


Adjustment Suggestion

The cell coverage capability is configured based on the cell type


(extended cell or not). The parameter is set to 63 fro common cells
and 219 for extended cells.

Change Mode

Offline

Related features

ZGO-04-01-001 Extended Cell Coverage

Related Parameters

[Cell]CellType
[Cell]DistanceThs
When "Cell Type (CellType)" is non-extended, the value range is 0 .. 63;

Relationship

When "Cell Type (CellType)" is extended, the value range is 0 .. 219;


In the process of handover control, DistanceThs cannot be higher than
the maximum value of TA.

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.2 TA MIN (TaMin)


Full Name

TA MIN

Abbreviation

TaMin

3GPP Name

None

3GPP Reference

None
It indicates the minimum TA accessing the cell. In homocentric circle coverage, this parameter is used with TaAllowed to limit the access of outer

Description

circle cells.

Managed Object

Cell
When "Cell Type (CellType)" is non-extended, the value range is 0..63;
Step: 1
When "Cell Type (CellType)" is extended, the value range is 0..219;

Value Range and Step

Step: 1

4-31
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

Default Value

The coverage area is not a homocentric circle by default and all users

Configuration Reason

within the coverage have access authorities.

Configuration Rule and

In homocentric circle coverage, TaMin can be increased to users near

Adjustment Suggestion

the certer point to use the outer circle resources.

Change Mode

Offline

Related features

ZGO-04-01-001 Extended Cell Coverage

Related Parameters

[Site]INFO1_1
The value of "Cell Type" has influence on the value range and default

Relationship

value of this parameter.


The parameter takes effect only when TLV is supported.

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.3 TA allowed (TaAllowed)


Full Name

TA allowed

Abbreviation

TaAllowed

3GPP Name

None

3GPP Reference

None
This parameter indicates the maximum TA that is allowed to access the
cell. If the delay time period requested by the channel exceeds the al-

Description

lowed range of TA, user access is not allowed.

Managed Object

Cell

4-32
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

When "Cell Type (CellType)" is non-extended, the value range is 0..63;


Step: 1
When "Cell Type (CellType)" is extended, the value range is 0..219;
Value Range and Step

Step: 1

Unit

None

Default Value

When "Cell Type (CellType)" is extended, the value range is 219;

When "Cell Type (CellType)" is non-extended, the default value is 63;

Default Value
Configuration Reason

Common cell by default

Configuration Rule and


Adjustment Suggestion

TaAllowed can be reduced to control the access coverage.

Change Mode

Offline

Related features

None

Related Parameters

[Site]INFO1_1
The value of "Cell Type" has influence on the value range and default

Relationship

value of this parameter.


The parameter takes effect only when TLV is supported.

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.4 PCH load indication period (CcchLoadIndPrd)


Full Name

PCH load indication period

Abbreviation

CcchLoadIndPrd

3GPP Name

CCCH Load Indication Period

3GPP Reference

3GPP TS 12.12 V8.0.0

4-33
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

In accordance with the GSM specifications, when the PCH channel (the
RACH channel) load level of BTS is over a threshold value (overload)
set by O&M, BTS will periodically send the "CCCH LOAD INDICATION"
message to BSC till the PCH (the RACH channel) channel is no longer
Description

over the threshold value.

Managed Object

Cell
1 .. 255

Value Range and Step

Step: 1

Unit

Default Value

Default Value
Configuration Reason

2S2S is enough for timely reporting overload and overload recovery.

Configuration Rule and


Adjustment Suggestion

It is recommended not to adjust the configuration of this parameter.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.5 Periodical location updating timer (T3212)


Full Name

Periodical location updating timer

Abbreviation

T3212

3GPP Name

T3212

3GPP Reference

3GPP TS 44.018 V5.13.0


4-34

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

In the GSM system, location updating results from three major causes.
One is normal updating that the MS finds change of the location area
(different LACs), the second is IMSI attach that location updating is performed after the MS is powered on, and the third is that the network specifies the MS to periodically update its location. Network controls the location time interval and depends upon T3212 timer. This parameter is
broadcast to all MSs in the cell by message RIL3_RR SYSTEM INFORDescription

MATION TYPE3.

Managed Object

Cell
0 .. 255
00: positive infinite, location update is not required;
1: 6 minutes;
2: 12 minutes;
255: 1530 minutes;

Value Range and Step

Step length: 1

Unit

360 s

Default Value

10

Default Value
Configuration Reason

This parameter should be negotiated with MSC. It is always set to 10.


This parameter affects the overall service performance of the network
and the utilization of the radio resource. For the area with higher traffic,
the period could be bigger (for example 16 or 20 hours, even 25 hours);
for the area with ordinary traffic, the value of T3212 could be smaller
(for example 3 or 6 hours); for the area with extreme overload traffic, it

Configuration Rule and


Adjustment Suggestion

is recommended to set T3212 as 0. The default value can be set to 10


(1 hour). Configuration of this parameter should be same within the
same location area, while the value that VLR periodically updates the
timer should be greater than this parameter. This parameter is set to 10
by default. It should be smaller than the implicit power-off duration of
CN. The value of T3212 under the same LAC should be consistent. In
case the coverage is poor, set this parameter to a small value, which has
assistance for increasing paging success rate.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

4-35
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

Yes
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.6 Protection period for access attempt (T3122)


Full Name

Protection period for access attempt

Abbreviation

T3122

3GPP Name

T3122

3GPP Reference

3GPP TS44.018 V5.22.0


The network sends IMMEDIATE ASSIGNMENT REJECT message to
MS when it receives a channel request message from MS and will not
allocate a suitable channel to MS.IMMEDIATE ASSIGNMENT REJECT
message contains T3122 timer parameter to prevent possible wireless
channel blocking caused by repeated channel requests sent by the MS,
which is waiting for indication information unit.
MS cannot restart a new call until the time indicated by T3122 is elapsed
if it receives the IMMEDIATE ASSIGNMENT REJECT message. This
parameter is also one of the system control parameters, and is sent to
MS in the IMMEDIATE ASSIGNMENT REJECT message.
Following are the suggested values: 10 s to 15 s for normal traffic area;

Description

15 s to 25 s for dense traffic area.

Managed Object

Cell
0 .. 255

Value Range and Step

Step: 1

Unit

Default Value

10

Default Value

Setting of the default value is in accordance with user's feel and network

Configuration Reason

resource utilization.

4-36
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Following are the suggested values: 10 s to 15 s for normal traffic area;


15 s to 25 s for dense traffic area. The cell traffic changes gradually
Configuration Rule and
Adjustment Suggestion

and cell abnormality occurs and recovers gradually. If the parameter is


set too small, the success rate of channel request is still low and the
system needs to process much load. If the parameter is set too large,
user's experience goes poor.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.7 Multi-band report indication (MulbandReport)


Full Name

Multi-band report indication

Abbreviation

MulbandReport

3GPP Name

MULTIBAND_REPORTING

3GPP Reference

3GPP TS45.008 V5.22.0


The MS in single-frequency GSM system only needs to report the
contents of six adjacent cells with the strongest signals in a frequency
band, when reporting the survey result of adjacent cells to the network.
In multi-band networking, MS can enter with priority into a specific
frequency band during handover. The MS reports the survey result
according to the signal intensity and the frequency band of the signals,
according to the actual situation.
Multiband report indication is used to notify MS to report contents of
adjacent cells in multiple frequency bands. It is one of the system control

Description

parameters.
4-37

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The setting of this parameter is subject to traffic in each frequency


band.General principles to set the parameters are as follows: 0: If the
traffic of each frequency band is almost equivalent, and the operator has
no choice over the frequency band. 3: If the traffic of each frequency
band is quite different, and the operator hopes that MS enters a specific
frequency band with priority.
The values are as follows:
0: The MS reports the survey results of six known and allowed adjacent
cells with the strongest NCC according to the signal intensity, regardless
of which frequency band adjacent cells are in.1: The MS reports the
measurement result of 1 adjacent cell with strongest signal in the
frequency bands in adjacent cell list (excluding the frequency band of
this cell).In the remaining space, the MS reports adjacent cell in this
cell frequency band. If still more space is available, the MS reports the
remaining adjacent cells, regardless of which frequency bands they
are in.
2: The MS reports the measurement result of 2 adjacent cells with
strongest signal in the frequency bands in adjacent cell list (excluding
the frequency band of this cell).In the remaining space, the MS reports
adjacent cell in this cell frequency band. If still more space is available,
the MS reports the remaining adjacent cells, regardless of which
frequency bands they are in.
3: The MS reports the measurement result of 3 adjacent cells with
strongest signal in the frequency bands in adjacent cell list (excluding
the frequency band of this cell).In the remaining space, the MS reports
adjacent cell in this cell frequency band. If still more space is available,
the MS reports the remaining adjacent cells, regardless of which
frequency bands they are in.
Managed Object

Cell
0 .. 3

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The cells in different frequency bands have more opportunities to report.

4-38
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

In the dual-band network scenario, the handover of MS in 1800M and


the traffic shared with 1800M are subject to the following settings: 3:
900M cells report 1800M adjacent cells as often as possible. 1: 1800M
Configuration Rule and
Adjustment Suggestion

cells report 900M adjacent cells as seldom as possible.


0: In the dual-band network scenario, the contents are reported
according to signal strength, to balance the traffic.
Reasonable setting is useful for traffic balance, congestion improvement.
Whereas, it may influence the handover success rate, calldrop rate,
and coverage rate.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.8 Coefficient of BVC bucket size (Info_2_0)


Full Name

Coefficient of BVC bucket size

Abbreviation

Info_2_0

3GPP Name

None

3GPP Reference

None
This parameter indicates the minimum access level of uplink RACH.
When BTS has received a channel request, it will measure the receive
level. If the receiving level is lower than the threshold, this access will be

Description

abandoned.

Managed Object

Cell

4-39
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

90..125
Value Range and Step

Step: 1

Unit

-dBm

Default Value

125

Default Value
Configuration Reason

Within the sensitivity range, it is not limited.

Configuration Rule and

coverage area will be reduced and the success rate of paging and

Adjustment Suggestion

handover will be lowered. However, the accessibility and the drop rate

The default value is recommended. If this index is increased, the

will be improved.
Change Mode

Offline

Related features

None

Related Parameters

[Site]INFO1_1

Relationship

The TLV parameter must be enabled to validate this functional


parameter.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.9 CCCH load indication (RACH) (CcchLoadINDThs_0)


Full Name

CCCH load indication (RACH)

Abbreviation

CcchLoadINDThs_0

3GPP Name

CCCH Load Threshold

3GPP Reference

3GPP TS 12.12 V8.0.0

4-40
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter specifies a threshold for the RACH load. When the RACH
load of the BTS exceeds this threshold, the BTS periodically sends a
CCCH LOAD INDICATION message to the iBSC until the RACH load deDescription

creases to a value lower than the threshold.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

80

Default Value
Configuration Reason

Generally, the RACH is considered very busy when its load reaches 80%.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.10 CCCH load indication (PCH) (CcchLoadINDThs_1)


Full Name

CCCH load indication (PCH)

Abbreviation

CcchLoadINDThs_1

3GPP Name

CCCH Load Threshold

3GPP Reference

3GPP TS 12.12 V8.0.0

4-41
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter specifies a threshold for the PCH load. When the PCH
load of the BTS exceeds this threshold, the BTS periodically sends a
CCCH LOAD INDICATION message to the iBSC until the PCH load deDescription

creases to a value lower than the threshold.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

80

Default Value
Configuration Reason

Generally, the PCH is considered very busy when its load reaches 80%.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.11 8PSK modulating power attenuation level (Tn7Lowerlevel)


Full Name

8PSK modulating power attenuation level

Abbreviation

Tn7Lowerlevel

3GPP Name

None

3GPP Reference

None

4-42
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter indicates the 8PSK modulating power attenuation level. If


BCCH carrier uses the channel with 8PSK modulation, the BCCH carrier
Description

is guaranteed to be sent at a constant power by setting this parameter.

Managed Object

Cell
0 .. 50

Value Range and Step

Step: 1

Unit

0.2 dB

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default is not adjusted.


Currently, the system does not support this function, and the modulation
power of BCCH Ts is reduced by 2 dB through the usage of 8PSK.
This parameter is valid until the TLV format is supported.

Change Mode

Offline

Related features

None

Related Parameters

[Site]INFO1_1

Relationship

This parameter is valid until the TLV parameter is enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.12 Repeated ACCH support (RepeatACCH)


Full Name

Repeated ACCH support

Abbreviation

RepeatACCH

3GPP Name

None

3GPP Reference

None

4-43
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines whether to use the FACCH/SACCH retransDescription

mission function.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

This is a new feature, keeping the same as before. It is disabled by

Configuration Reason

default.

Configuration Rule and


Adjustment Suggestion

It is recommended to enable this function after AMR is enabled, so as


to improve the set-up success rate, whilst currently few mobile phones
support the repeat SACCH.

Change Mode

Offline

Related features

ZGO-04-02-009 Repeated FACCH/SACCH

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.13 Start PA power off (StartPAPowerOff)


Full Name

Start PA power off

Abbreviation

StartPAPowerOff

3GPP Name

None

3GPP Reference

None

4-44
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter is to save energy and reduce consumption. BTS system


can turn off PA offset voltage while close power for idle timeslots. If the
configuration is conducted on BTS, FPGA can determine whether PA offDescription

set voltage shall be turned off.

Managed Object

Cell
Yes, No
Yes: enable

Value Range and Step

No: disable

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.

Configuration Rule and


Adjustment Suggestion

Turn on this switch when needed.

Change Mode

Offline

Related features

ZGO-04-04-003 Intelligent Timeslot Shutdown

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.14 Switch flag of cell TRX power off (StartTRXPowerOff)


Full Name

Switch flag of cell TRX power off

Abbreviation

StartTRXPowerOff

3GPP Name

None

3GPP Reference

None
4-45

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Description

It marks whether "Switch Flag of Cell TRX Power Off" is enabled.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a switch for a special function. The switch is disabled by default.


When the function is enabled, the BTS will reduce the traffic to a certain
extent and will shut down part of the transceiver functions for power
saving.

Change Mode

Offline

Related features

ZGO-04-04-002 Load Dependent Intelligent TRX Shutdown

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.15 Support intelligent cell shuttingdown (CellShuttingDown)


Full Name

Support intelligent cell shuttingdown

Abbreviation

CellShuttingDown

3GPP Name

None

3GPP Reference

None

4-46
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter determines whether to support the function of intelligent


cell power-off.
In a dual-band network, if the 900M cell contains the coverage of the
1800M cell and meanwhile the 1800M cell supports the function of
intelligent cell shutdown, the 1800M cell checks the traffic conditions
for carrier shutdown and starts to shut down the carrier in the period
allowed by the intelligent carrier shutdown function. The carrier should
be shut down when the cell processes no services and the BCCH carrier
Description

is the last carrier that is shut down.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This parameter is a functional switch, which is disabled by default.


In a dual-band network, if the 1800M cell is covered by another cell
such as a 900M cell, this function can be enabled according to operator
requirements.

Change Mode

Offline

Related features

ZGO-04-04-007 Intelligent Cell Shutdown

Related Parameters

[Cell]StartTRXPowerOff

Relationship

To enable the function of intelligent cell shutdown, the function of


intelligent carrier shutdown function must be enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4-47
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.2.16 Upper Site Id (UPSITEID)


Full Name

Upper Site Id

Abbreviation

UPSITEID

3GPP Name

None

3GPP Reference

None
This parameter indicates the station number of the upper layer cell. If this
cell is an 1800M cell and the station number of upper layer 900M cell is
configured when the function of intelligent cell shutdown is enabled, this
cell will shut down or start the BCCH carrier according to the traffic of the

Description

upper layer cell.

Managed Object

Cell

Value Range and Step

0..1536

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is configured according to the network coverage on site.

Configuration Rule and


Adjustment Suggestion

This parameter is configured according to the network coverage on site.

Change Mode

Offline

Related features

ZGO-04-04-007 Intelligent Cell Shutdown

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4-48
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.2.17 Upper Cell Id (UPBTSID)


Full Name

Upper Cell Id(

Abbreviation

UPBTSID

3GPP Name

None

3GPP Reference

None
This parameter indicates the station number of the upper layer cell. If this
cell is an 1800M cell and the station number of upper layer 900M cell is
configured when the function of intelligent cell shutdown is enabled, this
cell will shut down or start the BCCH carrier according to the traffic of the

Description

upper layer cell.

Managed Object

Cell

Value Range and Step

0..24

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is configured according to the network coverage on site.

Configuration Rule and


Adjustment Suggestion

This parameter is configured according to the network coverage on site.

Change Mode

Offline

Related features

ZGO-04-04-007 Intelligent Cell Shutdown

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4-49
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.2.18 AMR codec adjust mode (AmrAdjMode)


Full Name

AMR codec adjust mode

Abbreviation

AmrAdjMode

3GPP Name

None

3GPP Reference

None
This parameter indicates which AMR rate adjustment mode is used. Two
adjustment modes are optional: AMR rapid rate adjustment mode: In
this mode, the adjustment time is controlled by the BTS. Interval-based
rate adjustment: In this mode, the adjustment time is determined by the
configuration in the operation and maintenance center. This parameter
is valid in the case of IPA and E1A.
In the rapid rate adjustment mode, the BTS uses the default adjustment
time, that is, 960 ms. In the interval-based rate adjustment mode, the
BTS uses the adjustment time (unit: 480 ms) configured in the operation
and maintenance center. For example, if the interval parameter is set to
1, the BTS adjusts the rate every 480 ms. If the interval parameter is set
to 2, the BTS adjusts the data rate every 960 ms.
AMR rate adjustment refers to the process that the MS reports CMR
through uplink speech frames to request for the adjustment of downlink
rate according to the calculated downlink C/I (compared with the
threshold). The base station sends CMC through downlink speech
frames to request for the adjustment of uplink rate according to the
calculated uplink C/I (compared with the threshold). When the calculated
C/I reaches the threshold, and the time since the previous adjustment
reaches the adjustment time specified by this parameter, the BTS
accepts the rate adjustment request of CMC and CMR. If the calculated
C/I reaches the threshold, but the adjustment interval does not reach the
adjustment time specified by this parameter, rate adjustment will not be

Description

performed.

Managed Object

Cell

Value Range and Step

AMR rapid rate adjustment mode, interval-based rate adjustment mode

Unit

None

Default Value

AMR rapid rate adjustment mode

Default Value

The rate adjustment is determined by the BTS. The interval of 960 ms is

Configuration Reason

appropriate for rate adjustment.

Configuration Rule and


Adjustment Suggestion

Generally, the default value is recommended. The rate adjustment is


determined by the BTS. The interval of 960 ms is appropriate for rate
adjustment.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)


4-50

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.19 AMR codec adjust interval (AmrAdjInterval)


Full Name

AMR codec adjust interval

Abbreviation

AmrAdjInterval

3GPP Name

None

3GPP Reference

None
This parameter specifies the interval for AMR codec adjustment. This
parameter is valid when the AmrAdjMode parameter is set to "Intervalbased adjustment mode". Refer to the description of AmrAdjMode for

Description

more information.

Managed Object

Cell
1..50

Value Range and Step

Step: 1

Unit

480 ms

Default Value

Default Value
Configuration Reason

When the adjustment is determined by the operation and maintenance


center, the smaller the parameter value is, the faster the adjustment is
performed.

4-51
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The default value is recommended. Generally, the AMR rapid rate


adjustment mode is adopted in the network, and the BTS can properly
Configuration Rule and
Adjustment Suggestion

control the adjustment. If operator intervene is needed for rate


adjustment, select the interval-based rate adjustment mode and set the
value of this parameter. The larger the parameter value is, the longer
the adjustment interval is, that is, the slower a rate adjustment is.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[Cell]AmrAdjMode

Relationship

This parameter is valid only when the AmrAdjMode parameter is set to


"Interval-based rate adjustment".

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.20 HR channel fragment repacking support (HRDfragSupport)


Full Name

HR channel fragment repacking support

Abbreviation

HRDfragSupport

3GPP Name

None

3GPP Reference

None
This parameter is a switch for HR channel fragment cleaning-up functions.

Description

It can be configured both on BSC level and cell level.

Managed Object

Cell
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

0: No

4-52
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.


This parameter can increase the number of full-rate channels and

Configuration Rule and


Adjustment Suggestion

improve the voice quality when a cell that applies dynamic half-rate
enable the HR fragment cleaning. This parameter can be enabled when
needed. The BSC global parameter needs to be turned on, and the
number of handover within a cell will increase.

Change Mode

Offline

Related features

ZGO-03-02-004 HR Concentration

Related Parameters

[BSC]HRDfragSupport
[Cell]Info_0_8
[Cell]Info_1_24
The HR fragment cleaning function can be enabled only when the
following three parameters have been enabled: BSC HRDfragSupport,

Relationship

BSC HoIntraEnable and HRDfragSupport. The ratio of idle TCH/F


channel to all available service channels is the starting threshold of HR
fragment cleaning function.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.21 Idle FR threshold For HR defrag (Info_0_8)


Full Name

Idle FR threshold For HR defrag

Abbreviation

Info_0_8

3GPP Name

None

3GPP Reference

None

4-53
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If the proportion of the idle TCH/F channels in a cell to all the available
service channels is lower than or equal to this threshold, the fragment
cleaning up function will be enabled. The calculation starts when the HR
Description

channel needs to be repacked, which is caused by release of user.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

Default Value

20

Default Value
Configuration Reason

The default value is a low proportion threshold.


This parameter defines that the proportion of idle TCH/F channels
are the start threshold for HR fragment cleaning up. If the threshold
is increased, HR fragment cleaning up will be started when there are

Configuration Rule and

many idle TCH/F channels, and there will be more inner-cell handovers

Adjustment Suggestion

caused by HR fragment cleaning up. If the threshold is decreased, HR


fragment cleaning up will be started when there are less idle TCH/F
channels, and there will be less inner-cell handovers caused by HR
fragment cleaning up.

Change Mode

Offline

Related features

ZGO-03-02-004 HR Concentration

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-54
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.2.22 Busy threshold for HR defrag (Info_1_24)


Full Name

Busy threshold for HR defrag

Abbreviation

Info_1_24

3GPP Name

None

3GPP Reference

None
The fragment management is started when the traffic of a cell exceeds
the busy threshold. The calculation starts when the HR channel repack
is caused by release of users. The result is the proportion of the occupied channels (including TCH/H, TCH/F and PDTCH) to all the available

Description

channels in a cell.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

Default Value

80

Default Value
Configuration Reason

HR fragment cleaning up will make the channel busier. .


This parameter defines the proportion of busy channels in a cell. If the
threshold is increased, HR fragment cleaning up will start conducted

Configuration Rule and

when the cell is busy, and there will be more inner-cell handovers caused

Adjustment Suggestion

by HR fragment cleaning up. If the threshold is decreased, HR fragment


cleaning up will start when the cell is not busy, and there will be less
inner-cell handovers caused by HR fragment cleaning up.

Change Mode

Offline

Related features

ZGO-03-02-004 HR Concentration

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

4-55
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

4.2.23 HR channel percentage threshold (HRTsPercentage)


Full Name

HR channel percentage threshold

Abbreviation

HRTsPercentage

3GPP Name

None

3GPP Reference

None
When the ratio of number of HR occupied times slots to the number of
all the service time slots is lower than this threshold, a new HR channel
can be generated. The occupied HR time slots include static HR time
slots and dynamically generated HR time slots.
The parameter can be configured on BSC and BTS. when
UseCellDynHRPara is set to "Yes", HRTsPercentage is used. When

Description

UseCellDynHRPara is set to "No", BSC global HRTsPercentage is used.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

Default Value

50

Default Value

The default start threshold for dynamic HR exceeds 50%. Too many HR

Configuration Reason

utility should be avoided.

Configuration Rule and


Adjustment Suggestion

The HR time slot proportion is set to control the utility of HR channels.


The proportion of the HR channels that can be used becomes higher if
the parameter is set higher.

Change Mode

Offline

Related features

ZGO-01-01-001 Half Rate

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-56
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.24 Threshold of AMR HR (AmrHRThs)


Full Name

Threshold of AMR HR

Abbreviation

AmrHRThs

3GPP Name

None

3GPP Reference

None
When busy timeslot(including TCHF occupied, TCHH/2 occupied,
available PD, and PD channel congested)/general timeslot
(including available TCHF, available TCHH/2, and available PD) >=
AmrHRThs/100, and carrier and cell support AMR, subsequent service
prefers AMR voice rate.
This threshold value can be configured on BSC and BTS, when "User
cell dynamic HR parameter" (UseCellDynHRPara) is yes, AmrHRThs
value configured by cell will be used, otherwise AmrHRThs configured

Description

by BSC is used.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

Default Value

50

Default Value

The default value should be smaller than the threshold of AMR HR and it

Configuration Reason

is set to 50, due to AMR half rate conversion is performed in priority.

Configuration Rule and

The larger the threshold of this parameter is, the higher the threshold

Adjustment Suggestion

of AMR HR is.

Change Mode

Offline
ZGO-03-02-006 Independent Threshold for Dynamic AMR HR/FR Con-

Related features

version

Related Parameters

[Cell]HRThs

Relationship

HRThsis greater than or equal to AmrHRThs.

4-57
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.25 Handover from FR to HR due to high load support


(FRThrHoSupport)
Full Name

Handover from FR to HR due to high load support

Abbreviation

FRThrHoSupport

3GPP Name

None

3GPP Reference

None
It indicates if FR->HR handover based on load is supported, When the
load of a cell increases, handover can be applied to improve the utilization

Description

ratio of the radio channel.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.


Turn on this switch when the cell needs to enable FR -> HR switch. This

Configuration Rule and

function can improve the utility rate of a radio channel when the traffic

Adjustment Suggestion

load in a cell increases. Poor HR voice quality can be improved by the


handover to FR channel.

Change Mode

Offline

Related features

ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters

None

4-58
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

iBSCV6.20.614d

Parameter Modifying
Detail

None

4.2.26 Intra-handover from HR to FR due to bad quality


(HRTFRHOSupport)
Full Name

Intra-handover from HR to FR due to bad quality

Abbreviation

HRTFRHOSupport

3GPP Name

None

3GPP Reference

None
This parameter determines whether to support HR-FR handover based
on quality. In the case of poor HR voice quality, the HR-FR handover can

Description

be triggered to improve voice quality.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and

When HR-FR handover is required for a cell, enable this switch. Poor

Adjustment Suggestion

HR voice quality can be improved by the handover to FR channel.

Change Mode

Offline

Related features

ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters

None

Relationship

None
4-59

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

iBSCV6.20.614d

Parameter Modifying
Detail

None

4.2.27 Start PA output voltage tuning (Info_0_0)


Full Name

Start PA output voltage tuning

Abbreviation

Info_0_0

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the TRX starts the function of adjusting

Description

PA voltage based on BTS output power.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.

Configuration Rule and

If this function is enabled, BTS will adjust PA voltage based on the

Adjustment Suggestion

output power.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

4-60
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.28 Enable RRU of cell power off (RRUPowerOff)


Full Name

Enable RRU of cell power off

Abbreviation

RRUPowerOff

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates whether the RRU switch-off.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.


When the cell RRU switch-off function needs to be enabled, this

Configuration Rule and

parameter should be set to "Yes". After this function is enabled, idle

Adjustment Suggestion

state RRU will shut down part of its function for electricity saving. When
the traffic increases, power on RRU.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

4-61
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.29 The switch of CIR report (ReportCIR)


Full Name

The switch of CIR report

Abbreviation

ReportCIR

3GPP Name

None

3GPP Reference

None
This parameter indicates whether CIR (C/I value) is included in the measurement report. CIR information can be obtained in "C/I measurement"

Description

and "carrier frequency measurement".

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.

Configuration Rule and


Adjustment Suggestion

The functional switch is turned on when needed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-62
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.30 The L2 frame of Lapdm fill random value (LapdmL2Cfg)


Full Name

The L2 frame of Lapdm fill random value

Abbreviation

LapdmL2Cfg

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the Lapdm L2 filling frame fills random
values.
It will be difficult to hack into the system if the random values are applied

Description

as the filling values, thus the calling security of users is guaranteed.

Managed Object

Cell
Yes/No

Value Range and Step

0: No (filling in the fixed value 0x2B); 1: Yes (filling in random values)

Unit

None

Default Value

No

Default Value
Configuration Reason

In most cases the encryption is disabled, so no fill-in value is needed.

Configuration Rule and

When the encryption is enabled, L2 fill-in frames in Lapdm should be

Adjustment Suggestion

selected to avoid wiretapping.

Change Mode

Offline

Related features

ZGO-06-02-002 Random Fill Bits

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-63
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.31 NCC permitted (NccPermitted)


Full Name

NCC permitted

Abbreviation

NccPermitted

3GPP Name

NCC Permitted

3GPP Reference

3GPP TS 44.018 V5.13.0


In dedicated mode (in call process), the MS should report the measured
signal of the adjacent cell to BTS, whilst each report can only contain up
to six adjacent cells. Therefore, it should report the cell that is likely to
be the target cell for handover, rather than report only by the size of signal level(usually, the MS should not report the cell of other GSM PLMN).
The function can be enabled by limiting the MS only to measure NCC as
some fixed values. The parameter NccPermitted lists the NCC set of the
cell that the MS measures. The MS only needs to compare the adjacent
NCC measured with NccPermitted due to the SCH channel of each cell
constantly transmits BSIC, whilst the NCC is the high 3 bits of BSIC. If
the measured result is in the NCC set, the MS reports it to BTS. If not,
the MS will discard it. The parameter NccPermitted is notified to the MS
through RIL3_RR SYSTEM INFORMATION TYPE2 and 6, and is one of

Description

the system control parameters.

Managed Object

Cell

Value Range and Step

0~7

Unit

None

Default Value

0, 1, 2, 3, 4, 5, 6, 7

Default Value

The default value is set in accordance with the on-site configuration

Configuration Reason

requirement.

Configuration Rule and


Adjustment Suggestion

If no special requirement, this parameter should not be modified.

Change Mode

Offline

Related features

None

4-64
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.2.32 Support allocating channel by TA (AllocChlByTA)


Full Name

Support allocating channel by TA

Abbreviation

AllocChlByTA

3GPP Name

None

3GPP Reference

None
This parameter determines whether channels in a cell are allocated for

Description

BCCH and non-BCCH carriers according to the TA value.

Managed Object

Cell
0: not support;

Value Range and Step

1: support

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Enable this switch according to operator requirements.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

4-65
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.2.33 The TA threshold of allocating channel in BCCH


(TaThsOfBCCH)
Full Name

The TA threshold of allocating channel in BCCH

Abbreviation

TaThsOfBCCH

3GPP Name

None

3GPP Reference

None
This parameter determines the TA threshold when the channels on the
BCCH carrier are allocated. If the TA value is lower than or equal to this
threshold, the system is prior to allocate the channels on the BCCH carrier.
Otherwise, the system is prior to allocate the channels on the non-BCCH

Description

carrier.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

By default, the subscribers near the BTS will be allocated on the BCCH
carrier. During actual application, adjust this value according to the
range of cell coverage.
This parameter is relevant to cell coverage. For metropolitan areas, this
parameter is configured relatively small. For suburban areas with wide
cell coverage, this parameter is configured relatively large.

Change Mode

Offline

Related features

None

Related Parameters

None
4-66

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.2.34 Cell PowerOff based on traffic load (PwDownLoadInd)


Full Name

Cell PowerOff based on traffic load

Abbreviation

PwDownLoadInd

3GPP Name

None

3GPP Reference

None

Description

Cell PowerOff based on traffic load

Managed Object

CELL
[0,1]

Value Range and Step

step: 1

Unit

None

Default Value

Default Value

The CSL power off function is disabled by default. Set the parameter to

Configuration Reason

0 to enable the CSL power off function, when load is not considered.

Configuration Rule and


Adjustment Suggestion

To enable the power-off function based on load, set the parameter to 1.


To enable the CSL power-off function that does not consider load, set
the parameter to 0.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

4-67
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID->Basic Params2

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

4.2.35 Support handover from HR to FR due to low load


(HRTFRHOSupport2)
Full Name

Support handover from HR to FR due to low load

Abbreviation

HRTFRHOSupport2

3GPP Name

None

3GPP Reference

None
This parameter specifies whether the handover from HR to FR due to low
load is enabled, including handovers from HR (V1) to FR and from HR

Description

(V3) to FR.

Managed Object

CELL
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This function is not enabled normally.

Configuration Rule and

This function can be enabled to improve the call quality when the cell

Adjustment Suggestion

load reduces from high level to a low level.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

4-68
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID-> Basic Params2

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

4.2.36 TRX PowerOff time bitmap (DownPowerBmp)


Full Name

TRX PowerOff time bitmap

Abbreviation

DownPowerBmp

3GPP Name

None

3GPP Reference

None

Description

TRX PowerOff time bitmap

Managed Object

CELL
[0,23]

Value Range and Step

step: 1

Unit

Hour

Default Value

Default Value

By default, the power off function is disabled.

Configuration Reason

If time bitmap is not selected, power off is also disabled.

Configuration Rule and


Adjustment Suggestion

The parameter must be set when the power off function is enabled. It is
recommended to select the time bitmap according to desired time period
when the carrier is powered off.

Change Mode

Offline

Related features

ZGO-04-04-002 Load Dependent Intelligent TRX Shutdown

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-69
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID->Basic Params2

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

4.3 Basic Parameters 3


4.3.1 Average bursts count surveyed by RACH (AvgSlots)
Full Name

Average bursts count surveyed by RACH

Abbreviation

AvgSlots

3GPP Name

RACH Load Averaging Slots

3GPP Reference

3GPP TS 12.12 V8.0.0


This parameter indicates the number of bursts (AvgSlots) on RACH. If the
receiving signal level of this parameter burst is higher than RachBusyThs,
the RACH channel overloads. This parameter is one of the parameters

Description

used by BTS.

Managed Object

Cell
0 .. 100

Value Range and Step

Step: 1

Unit

None

Default Value

60

Default Value
Configuration Reason

The experience value is taken in accordance with the access busyness.

Configuration Rule and


Adjustment Suggestion

It is suggested to keep the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

4-70
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.2 RACH receiving signal level threshold for busy burst


(RachBusyThs)
Full Name

RACH receiving signal level threshold for busy burst

Abbreviation

RachBusyThs

3GPP Name

RACH Busy Threshold

3GPP Reference

3GPP TS 12.12 V8.0.0


This parameter indicates the receiving signal level threshold in the period
of RACH bursts. If the threhold is exceeded (that is less than RACH Receiving signal level threshold for busy burst dBm), the system considers

Description

that as a busy RACH.

Managed Object

Cell
0 .. 63
00: < -110 dBm;
1: -110 dBm .. -109 dBm;
2: -109 dBm .. -108 dBm;
...
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

63

Default Value
Configuration Reason

The largest value ( by default)

Configuration Rule and


Adjustment Suggestion

It is suggested to keep the default value.

Change Mode

Offline

Related features

None

4-71
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


3
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.3 RACH load indication period (OverloadPrd)


Full Name

RACH load indication period

Abbreviation

OverloadPrd

3GPP Name

Overload Period

3GPP Reference

3GPP TS 12.12 V8.0.0


In accordance with the GSM regulations, if the Access Burst level exceeds the predefined access level busy threshold(RACHBusyThs), the
Access Burst is judged to be busy burst. During the period of RACH overload measurement, if the ratio of the number of Busy Bursts to all Access
Bursts exceeds the RACH overload threshold, the MS reports the CCCH

Description

LOAD INDICATION message.

Managed Object

Cell
1 .. 255

Value Range and Step

Step: 1

Unit

Default Value

Default Value
Configuration Reason

2S is long enough for timely reporting overload and overload recovery.

Configuration Rule and


Adjustment Suggestion

It is suggested to keep the default value.

Change Mode

Offline

4-72
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.4 BA show (BcchBaInd)


Full Name

BA show

Abbreviation

BcchBaInd

3GPP Name

BA ind

3GPP Reference

3GPP TS 44.018 V5.13.0


This parameter indicates the BA show of BCCH. The adjacent cell list
can be broadcast on BCCH and transferred on SACCH. The adjacent
cell list transferred on BCCH can be different from that on SACCH. When
the MS reports the measurement data of adjacent cell, either BCCH
adjacent cell list or SACCH adjacent cell list will be referred. Therefore,
in order to know which adjacent cell list is referred by the MS, a BA show
is added when the adjacent cell list is transferred on BCCH and SACCH.
When reporting the measurement result, the MS notifies the network side
about the corresponding BA show of the referred adjacent cell list. As a
result, the network side recognizes which adjacent cell list the MS uses.
This parameter describes the BA show value when the adjacent cell list
is transferred on BCCH.In the case of transferring adjacent cell list on
SACCH, the BA show value used is the reverse of the parameter.
0: The value of BA_IND on BCCH (system message 2, 2bis, 2ter) is 0;
the value of BA_IND on SACCH (system message 5, 5bis, 5ter) is 1.
1: The value of BA_IND on BCCH (system message 2, 2bis, 2ter) is 1;

Description

the value of BA_IND on SACCH (system message 5, 5bis, 5ter) is 0.

4-73
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell

Value Range and Step

0, 1

Unit

None

Default Value

Default Value
Configuration Reason

No reason

Configuration Rule and


Adjustment Suggestion

It is suggested to keep the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


3
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.5 MIN received signal level to access (RxLevAccessMin)


Full Name

MIN received signal level to access

Abbreviation

RxLevAccessMin

3GPP Name

RXLEV_ACCESS_MIN

3GPP Reference

3GPP TS45.008 V5.22.0

4-74
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

To prevent the MS from accessing the system at a low receiving signal


level (usually, the poor communication quality cannot guarantee normal
communications after access), and from unreasonably wasting the
radio sources in the network, it is specified in the GSM system that the
receiving level must be higher than a threshold for MS to access the
network, that is, MS Min RxLev to Access (the minimum receiving level
for the MS to access the network).
In addition, it is one of the criteria for MS to select and reselect the
cell. This parameter will be broadcast to all MSs in the cell through
the "RIL3_RR SYSTEM INFORMATION TYPE3" and "TYPE4"
messages.MIN receiving signal level allowed to access is one of the
cell selection parameters.
Usually, the suggested value should be approximate to the MS
receiving sensitivity. For some cells with overloaded traffic, the cells
"RxLevAccessMin" may be appropriately increased to decrease the
C1 and C2 values of the cell and reduce the cells effective coverage.
However, the "RxLevAccessMin" value cannot be too large, otherwise, a
"blind area" will be created at the cell boundaries factitiously.
With this measure for traffic balance, it is suggested that the level value
should not exceed -90 dBm.At the preliminary running stage of the
network, this parameter can be usually set as 10 (that is, -101 dBm ~
-100 dBm) or lower, which is higher than the MS receiving sensitivity
102 dBm. However, when the network capacity is expanded or the
radio coverage in a cell is not a problem, this parameter of the cell can
Description

be increased.

Managed Object

Cell
0 .. 63
00: < -110 dBm;
1: -110 dBm .. -109 dBm;
2: -110 dBm .. -109 dBm;
...
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

10(-101 dBm~-100 dBm)

Default Value
Configuration Reason

The default value is set to be a little higher than the MS' sensitivity.

Configuration Rule and

should be no greater than 15.

Adjustment Suggestion

If the value is increased, the effective coverage range will be reduced,

The value can be slightly adjusted based on the actual condition. It

which helps improve the access success rate but reduces call drop rate.

4-75
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGB-02-02-007 Support of C1 Criteria

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


3
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.6 MAX number of re-transmitting events times (MRetrans)


Full Name

MAX number of re-transmitting events times

Abbreviation

MRetrans

3GPP Name

Max retrans

3GPP Reference

3GPP TS44.018 V5.22.0


When the MS starts the immediate assignment process (for example,
the MS needs to update the location, originate a call or respond to a
paging), it will send the channel request message in the RACH channel
to the network.
RACH is an ALOHA channel, the network enables the MS to send
multiple channel request messages before the MS receives the
IMMEDIATE ASSIGNMENT message to increase the access success
rate of MS. The maximum number of allowable resend times depends
on the maximum number of re-transmitting events times.
This parameter information is broadcast to the MS in the cell through the
RIL3_RR SYSTEM INFORMATION TYPE1, 2, 2bis, 3 and 4 messages.
MAX number of re-transmitting events times is one of the control
parameters of the GSM system.
For the cell radius over 3 km and the area with small traffic, it can be set
as 3 (that is, the maximum number of resending times is 7) to improve

Description

the access success rate of the MS.

4-76
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

For the cell radius less than 3 km and the area with common traffic, it
can be set as 2 (the maximum number of resending times is 4).
For the micro cellular, it is suggested to set it as 1 (that is, the maximum
number of resending times is 2).
For the micro cell with heavy traffic and the cell with obvious congestion,
it is suggested to set it as 0 (that is, the maximum number of resending
times is 1).
Managed Object

Cell
0 .. 3
0: 1 times;
1: 2 times;
2: 4 times;

Value Range and Step

3: 7 times

Unit

None

Default Value

2(4 times)

Default Value

The number of attempts is increased appropriately to improve the

Configuration Reason

access success rate.

Configuration Rule and


Adjustment Suggestion

It is suggested to reserve the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-77
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.3.7 Number of slots to spread transmission (TxInteger)


Full Name

Number of slots to spread transmission

Abbreviation

TxInteger

3GPP Name

Tx_integer

3GPP Reference

3GPP TS44.018 V5.22.0


This parameter is used at the MS side. It belongs to the PRACH
and RACH control parameters, and is broadcast to the MS in the
SI1, SI2, I2bis, SI3 and SI messages.Whenever establishing a new
connection, the MS usually sends the channel request message in the
PRACH/RACH channel to the network.PRACH is an ALOHA channel, so
the network allows the MS to send multiple channel request messages
before receiving the packet assignment message, to improve the
access success rate. When the previous channel request message
is not responded, the MS will re-send the channel request message
after waiting for a random period. This parameter is to determine the
random waiting time. The timeslot interval between two channel request
messages should be valued randomly from {S, S+1..., S+T-1}.
The relationship between S and T is as follows.
When T is 3, 8, 14, or 50, S is 55 (CCCH) or 41 (CCH/SDCCH).
When T is 4, 9, or 16, S is 76 (CCCH) or 52 (CCH/SDCCH).
When T is 5, 10, or 20, S is 109 (CCCH) or 58 (CCH/SDCCH).
When T is 6, 11, 14, or 25, S is 163 (CCCH) or 86 (CCH/SDCCH).

Description

When T is 7, 12, or 32, S is 217 (CCCH) or 115 (CCH/SDCCH).

Managed Object

Cell
0 .. 15
0: T is 3;
1: T is 4;
2: T is 5;
3: T is 6;
4: T is 7;
5: T is 8;
6: T is 9;
7: T is 10;
8: T is 11;
9: T is 12;
10: T is 14;
11: T is 16;
12: T is 20;
13: T is 25;
14: T is 32;

Value Range and Step

15: T is 50.

4-78
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Unit

None

Default Value

14

Default Value

Configuration of the default value is to expand the transmission interval

Configuration Reason

and leave sufficient time for the network side to process.

Configuration Rule and


Adjustment Suggestion

The value 14 corresponds to the maximum value of retransmission


interval. If no special requirement, it is recommended not to modify the
parameter value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.8 Control channel MAX power level (MsTxPwrMaxCch)


Full Name

Control channel MAX power level

Abbreviation

MsTxPwrMaxCch

3GPP Name

MS_TXPWR_MAX_CCH

3GPP Reference

3GPP TS45.008 V5.22.0

4-79
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

During the communication between the MS and the BTS, the


transmission power of the MS is controlled by the network. The network
sets the power for the MS through the power command which is
transmitted on SACCH (SACCH has 2 header bytes, one is the power
control byte and the other is the timing advance byte). The MS must
extract the power control header from the DL SACCH and take the
specified transmission power as output power. If the power level of the
MS cannot make it output the power value, it will output the closest
transmission power that can be output.Parameter setting varies from
different frequency band.
SACCH is Channel Associated Signaling and it has to be used together
with SCCCH and TCH, so the power control of MS starts after the MS
receives the SACCH.
The power of the MS before receiving SACCH (that is the power when
sending channel request on RACH) is determined by Control channel
MAX power level.
MsTxPwrMaxCch is also one of the cell selection and reselection
parameters of the MS, involved in calculation of C1 and C2 values.
It is broadcast to all MSs in the cell via RIL3_RR SYSTEM
INFORMATION TYPE3 and TYPE4 and is one of the cell selection
Description

parameters.

Managed Object

Cell
0 .. 31

Value Range and Step

Step: 1

Unit

None

Default Value

900 M: 5; 1800 M: 0

Default Value
Configuration Reason

The default value is the maximum power of most MS.


The default value is reserved. If the it is set too large, the MS near BTS
will interfere the adjacent channels. If it is too small, the MS at the cell
boundaries will have low access success rate.

Configuration Rule and


Adjustment Suggestion

The principle for setting the parameter value is: Under the precondition
that the MS at the cell boundary is guaranteed with a certain access
success rate, the MS access level should be reduced as much as
possible.Obviously, the larger the cell coverage is, the higher is the
output power level of the MS. Usually, it is recommended to set this
parameter value as 5 (for GSM900MS) and 0 (for GSM1800MS).

Change Mode

Offline

Related features

ZGB-02-02-007 Support of C1 Criteria

Related Parameters

None

4-80
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.9 Number of multi-frames of the PCH (BsPaMframs)


Full Name

Number of multi-frames of the PCH

Abbreviation

BsPaMframs

3GPP Name

BS_PA_MFRMS

3GPP Reference

3GPP TS45.002
Number of multiframes of the PCH specifies the repeat cycle of PCH
group subchannel using multiple 51-MultiFrame structures. It is one
of the system control parameters.
According to GSM Specifications, a unique IMSI identifies an MS and
paging group. IMSI determines the PCH sub-channel for MS in a paging
group.
In the actual network, MS tunes only to the paging sub-channel during
IDLE mode in the serving cell and ignores other paging sub-channels. In
other IDLE time, MS shuts off the hardware equipment power supply to
save power. Number of multiframes of the PCH determines the number
of paging sub-channels of the paging channel in a cell.
an MS uses this parameter to find out its home paging group, so as
to monitor corresponding paging sub-channel. Network broadcasts
the parameter information to all MSs in the cell through SYSTEM
INFORMATION messages. Number of multiframes is broadcast to MSs

Description

through RIL3_RR SYSTEM INFORMATION TYPE3 messages.

Managed Object

Cell
2..9

Value Range and Step

Step: 1

4-81
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

Default Value

This parameter should be set as low as possible and the paging channel

Configuration Reason

should not be overloaded.


There will be more paging sub-channels if this parameter is set higher,
and at the same time the number users in each sub-channel will be lower.
The traffic overload on paging channels should be checked regularly,
based on which the the parameter value shall be adjusted. Usually, for

Configuration Rule and


Adjustment Suggestion

the area with large traffic, this parameter should be 6 or 7. In the area
with moderate traffic, this parameter can be set as 4 or 5. For the area
with small traffic, this parameter can be set as 2 or 3.
Any one of the paging messages in a same location area must be sent
among all the cells in this area at the same time, so the channel volume
for each cell in a location area should be same or approximately the
same.

Change Mode

Offline

Related features

ZGB-02-01-001 paging

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.10 Interval of SDCCH re-sending PHY info message (T3105d)


Full Name

Interval of SDCCH re-sending PHY info message

Abbreviation

T3105d

3GPP Name

T3105

3GPP Reference

3GPP TS44.018
4-82

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter indicates the repeat interval of the RIL3_RR PHYSICAL


INFOMATION message in a asynchronous handover process on
SDCCH.
Start: When an RIL3_RR PHYSICAL INFORMATION message is sent
at the network side.
Stop: When the network receives a layer-2 frame that can be correctly
decoded, or a HANDOVER FAILURE message on the old channel.
At expiry: Send the RIL3_RR PHYSICAL INFORMATION message
Description

again.

Managed Object

Cell
1..67

Value Range and Step

Step: 1

Unit

10 ms

Default Value

10

Default Value

The default value is set in consideration of the minimum delay of

Configuration Reason

message interaction at the radio interface.


Physical information is sent over FACCH, which occurs every four TDMA
frames. That is, the physical information is sent every 18 ms. Therefore,
20 ms is recommended as an appropriate minimum value.

Configuration Rule and

When adjusting the parameter value, take the following into

Adjustment Suggestion

consideration: a too short interval may cause the transmission of too


much redundant information;
a too long interval may reduce the access speed of the MS when the
radio environment is bad.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

4-83
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

4.3.11 Interval of TCH re-sending PHY info message (T3105f)


Full Name

Interval of TCH re-sending PHY info message

Abbreviation

T3105f

3GPP Name

T3105

3GPP Reference

3GPP TS44.018
This parameter indicates the repeat interval of the RIL3_RR PHYSICAL
INFOMATION message in a asynchronous handover process on TCH.
Start: When an RIL3_RR PHYSICAL INFORMATION message is sent
at the network side.
Stop: When the network receives a layer-2 frame that can be correctly
decoded, or a HANDOVER FAILURE message on the old channel.
At expiry: Send the RIL3_RR PHYSICAL INFORMATION message

Description

again.

Managed Object

Cell
1..255

Value Range and Step

Step: 1

Unit

10 ms

Default Value

10

Default Value

The default value is set in consideration of the minimum delay of

Configuration Reason

message interaction at the radio interface.


Physical information is sent over FACCH, which occurs every four TDMA
frames. That is, the physical information is sent every 18 ms. Therefore,
20 ms is recommended as an appropriate minimum value.

Configuration Rule and

When adjusting the parameter value, take the following into

Adjustment Suggestion

consideration: a too short interval may cause the transmission of too


much redundant information;
a too long interval may reduce the access speed of the MS when the
radio environment is bad.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

4-84
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.12 MAX resending times for physical information (NY1)


Full Name

MAX resending times for physical information

Abbreviation

NY1

3GPP Name

Ny1

3GPP Reference

3GPP TS44.018
As specified by GSM standard, the BTS needs to inform the MS
about the time advance to be used through an RIL3_RR PHYSICAL
INFORMATION message. After the BTS sends the RIL3_RR PHYSICAL
INFORMATION message, timer T3105 is started. If layer-2 frames or
TCH frames fails cannot be correctly decoded before the expiry of the
timer, the BTS sends the RIL3_RR PHYSICAL INFORMATION message
again and restarted timer T3105.
This parameter (NY1) indicates the maximum number of repetitions that

Description

the RIL3_RR PHYSICAL INFORMATION message can be sent.

Managed Object

Cell
5..50

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value is set in consideration of the maximum delay of

Configuration Reason

message interaction at the radio interface.

4-85
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

A too small parameter value will reduce the retransmission times and
thus decrease the transmission success rate.
Configuration Rule and

A too large parameter value may cause the waste of radio resources.

Adjustment Suggestion

The parameter value can be appropriately increased in the case of


slow handover or low handover success rate caused by bad clock or
transmission.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.13 Number of blocks reserved for AGCH (BsAgBlkRes)


Full Name

Number of blocks reserved for AGCH

Abbreviation

BsAgBlkRes

3GPP Name

BS_AG_BLKS_RES

3GPP Reference

3GPP TS45.002
This is the number of blocks used for AGCH in the 51 multiframes
(BS-AG-BLK-RES).
Because CCCH channel has both Access Grant Channel (AGCH) and
Paging Channel (PCH), a number should be set to indicate how many
CCCH information blocks are reserved for AGCH.To let MSs know
this configuration, there is a configuration parameter in the system

Description

messages in each cell.

4-86
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter can be dynamically adjusted according to the load status


of different types of common channels. It is broadcast to all MSs in the
cell through the "RIL3_RR SYSTEM INFORMATION TYPE3" message.
Managed Object

Cell
0..7

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

"2" is a recommended value.

Configuration Rule and

It is recommended that the values of this parameter for all the cells in

Adjustment Suggestion

the same local area are identical.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.14 BSS radio link timer's max value for AMR FR


(BsRadioLkTmOutForAMRFR)
Full Name

BSS radio link timer's max value for AMR FR

Abbreviation

BsRadioLkTmOutForAMRFR

3GPP Name

RADIO_LINK_TIMEOUT

3GPP Reference

45.008

4-87
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the maximum value (initial value) of S that is


the counter for AMR-FRvoice service failure. GSM rule specifies that
BTS needs a counter S, which is rendered a value recorded in parameter BsRadioLkTmout when the call starts. Once BTS fails to decode a
correct SACCH message when it should, S will decrease by 1. Once BTS
decodes a correct SACCH message, S is increased by 2. The value of
S cannot exceed BsRadioLkTmout. When S reaches 0, BTS will report
Description

radio link fault. This counter is designed for AMR-FR voice service.

Managed Object

Cell

Value Range and Step

4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, 64

Unit

None

Default Value

64

Default Value

This parameter can have a big value, so there will be plenty of time

Configuration Reason

to restore the normal quality call.


When this parameter has a big value, there will be plenty of time to

Configuration Rule and

restore the normal quality call. When the parameter has a small value,

Adjustment Suggestion

it is difficult to restore the normal quality call and the radio resources
will be released.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-88
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.3.15 BSS radio link timer's max value for AMR HR


(BsRadioLkTmOutForAMRHR)
Full Name

BSS radio link timer's max value for AMR HR

Abbreviation

BsRadioLkTmOutForAMRHR

3GPP Name

RADIO_LINK_TIMEOUT

3GPP Reference

45.008
This parameter indicates the maximum value (initial value) of S that is
the counter for AMR-HRvoice service failure. GSM rule specifies that
BTS needs a counter S, which is rendered a value recorded in parameter
BsRadioLkTmout when the call starts. Once BTS fails to decode a correct SACCH message when it should, S will decrease by 1. Once BTS
decodes a correct SACCH message, S is increased by 2. The value of
S cannot exceed BsRadioLkTmout. When S reaches 0, BTS will report

Description

radio link fault. This counter is designed for AMR-HR voice service.

Managed Object

Cell

Value Range and Step

4, 8, 12, 16, 20, 24, 28, 32, 36, 40 44, 48, 52, 56, 60, 64

Unit

None

Default Value

64

Default Value

This parameter can have a big value, so there will be plenty of time

Configuration Reason

to restore the normal quality call.


When this parameter has a big value, there will be plenty of time to

Configuration Rule and

restore the normal quality call. When the parameter has a small value,

Adjustment Suggestion

it is difficult to restore the normal quality call and the radio resources
will be released.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


2

4-89
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.16 BSS radio link timers max value for AMR WFS
(BsRadioLkOutAMRWFS)
Full Name

BSS radio link timers max value for AMR WFS

Abbreviation

BsRadioLkOutAMRWFS

3GPP Name

RADIO_LINK_TIMEOUT

3GPP Reference

45.008
This parameter determines the maximum value (initial value) of counter
S for AMR-FR voice failure detection. The GSM specification stipulates
that the BTS requires a counter S, which is assigned with an initial value
when conversation starts, that is, the value of the BsRadioLkTmout parameter. Each time the BTS fails to decode a correct SACCH message
when receiving a message, S will be decreased by 1. Each time the BTS
receives a correct SACCH message, S will be increased by 2. However,
the value of S cannot exceed the value of BsRadioLkTmout. When S
reaches 0, the BTS will report a radio link fault. This counter is designed

Description

for the AMR-FR voice service.

Managed Object

Cell
0: 4
1: 8
2: 12
3: 16
4: 20
5: 24
6: 28
7: 32
8: 36
9: 40
10: 44
11: 48
12: 52
13: 56
14: 60

Value Range and Step

15: 64

Unit

None

4-90
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value

15

Default Value
Configuration Reason

None
When this parameter is configured to a large value, wait to restore the

Configuration Rule and


Adjustment Suggestion

poor channel quality. When the parameter is configured to a small value,


it is difficult to restore the normal channel quality. In this case, some
measures should be taken in advance to prevent call drops and release
radio resources.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface, Abis Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.17 BSS radio link timer's max value for AMR OWFS
(BsRadioLkOutAMROWFS)
Full Name

BSS radio link timer's max value for AMR OWFS

Abbreviation

BsRadioLkOutAMROWFS

3GPP Name

RADIO_LINK_TIMEOUT

3GPP Reference

45.008

4-91
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines the maximum value (initial value) of counter


S for AMR-HR voice failure detection. The GSM specification stipulates
that the BTS requires a counter S, which is assigned with an initial value
when conversation starts, that is, the value of the BsRadioLkTmout parameter. Each time the BTS fails to decode a correct SACCH message
when receiving a message, S will be decreased by 1. Each time the BTS
receives a correct SACCH message, S will be increased by 2. However,
the value of S cannot exceed the value of BsRadioLkTmout. When S
reaches 0, the BTS will report a radio link fault. This counter is designed
Description

for the AMR-HR voice service.

Managed Object

Cell
0: 4
1: 8
2: 12
3: 16
4: 20
5: 24
6: 28
7: 32
8: 36
9: 40
10: 44
11: 48
12: 52
13: 56
14: 60

Value Range and Step

15: 64

Unit

None

Default Value

15

Default Value
Configuration Reason

None
When this parameter is configured to a large value, wait to restore the

Configuration Rule and


Adjustment Suggestion

poor channel quality. When the parameter is configured to a small value,


it is difficult to restore the normal channel quality. In this case, some
measures should be taken in advance to prevent call drops and release
radio resources.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface, Abis Interface


4-92

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.18 BSS radio link timers max value for AMR OWHS
(BsRadioLkOutAMROWHr)
Full Name

BSS radio link timers max value for AMR OWHS

Abbreviation

BsRadioLkOutAMROWHr

3GPP Name

RADIO_LINK_TIMEOUT

3GPP Reference

3GPP TS45.008 V5.22.0


This parameter determines the maximum value of radio link counter S at

Description

the BSS side. It is used in the same way as MsRadioLKTmOut.

Managed Object

Cell
0: 4
1: 8
2: 12
3: 16
4: 20
5: 24
6: 28
7: 32
8: 36
9: 40
10: 44
11: 48
12: 52
13: 56
14: 60

Value Range and Step

15: 64

Unit

None

4-93
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

15

Default Value
Configuration Reason

None
The parameter is directly correlated with the call drop rate. The higher

Configuration Rule and


Adjustment Suggestion

the value, the lower the call drop rate. To improve the KPI of call drop
rate, this parameter can be configured to a large value. However, it has
negative impact on user perception.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis Interface

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


3
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.19 LAPDM timer used for controlling the SDCCH channel.


(T200_0)
Full Name

LAPDM timer used for controlling the SDCCH channel.

Abbreviation

T200_0

3GPP Name

T200

3GPP Reference

3GPP TS44.006

4-94
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

T200 is a timer used for different control channels specified by the


LAPDm protocol of the BTS. This timer, T200_0, is only used for SDCCH.
Start: When an I frame is sent on SDCCH.
Stop: When an RR frame is received from the MS.
At expiry: Check whether the number of times that the timer expires is
equal to N200. If no, the BTS keeps sending the frame before the timer
expiry. If yes, the BTS sends an error report to the BSC, initiates an
Description

exception release process, and changes the status of LAPDm to IDLE.

Managed Object

Cell
1..7

Value Range and Step

Step: 1

Unit

5 ms

Default Value

Default Value
Configuration Reason

The default value is the maximum value recommended by the protocol.

Configuration Rule and

will be sent.

Adjustment Suggestion

If the parameter value is too large, the access speed of the MS will be

If the parameter value is too small, too much redundant information

reduced when the radio environment is bad.


Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-95
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.3.20 Lapdm Timer for controlling FACCH/full rate channel


(T200_1)
Full Name

Lapdm Timer for controlling FACCH/full rate channel

Abbreviation

T200_1

3GPP Name

T200

3GPP Reference

3GPP TS44.006
T200 is a timer used for different control channels specified by the
LAPDm protocol of the BTS. This timer, T200_1, is only used for
FACCH/FULL RATE.
Start: When an I frame is sent on FACCH.
Stop: When an RR frame is received from the MS.
At expiry: Check whether the number of times that the timer expires is
equal to N200. If no, the BTS keeps sending the frame before the timer
expiry. If yes, the BTS sends an error report to the BSC, initiates an

Description

exception release process, and changes the status of LAPDm to IDLE.

Managed Object

Cell
1..7

Value Range and Step

Step: 1

Unit

5 ms

Default Value

Default Value
Configuration Reason

The default value is the maximum value recommended by the protocol.


If the parameter value is too small, too much redundant information

Configuration Rule and

will be sent.

Adjustment Suggestion

If the parameter value is too large, the access speed of the MS will be
reduced when the radio environment is bad.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3
4-96

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.21 Lapdm Timer for controlling FACCH/half rate channel


(T200_2)
Full Name

Lapdm Timer for controlling FACCH/half rate channel

Abbreviation

T200_2

3GPP Name

T200

3GPP Reference

3GPP TS44.006
T200 is a timer used for different control channels specified by the
LAPDm protocol of the BTS. This timer, T200_2, is only used for
FACCH/HALF RATE.
Start: When an I frame is sent on FACCH.
Stop: When an RR frame is received from the MS.
At expiry: Check whether the number of times that the timer expires is
equal to N200. If no, the BTS keeps sending the frame before the timer
expiry. If yes, the BTS sends an error report to the BSC, initiates an

Description

exception release process, and changes the status of LAPDm to IDLE.

Managed Object

Cell
1..7

Value Range and Step

Step: 1

Unit

5 ms

Default Value

Default Value
Configuration Reason

The default value is the maximum value recommended by the protocol.


If the parameter value is too small, too much redundant information

Configuration Rule and

will be sent.

Adjustment Suggestion

If the parameter value is too large, the access speed of the MS will be
reduced when the radio environment is bad.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None
4-97

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.22 Lapdm Timer for controlling SACCH with tch sapi0 channel
(T200_3)
Full Name

Lapdm Timer for controlling SACCH with tch sapi0 channel

Abbreviation

T200_3

3GPP Name

T200

3GPP Reference

3GPP TS44.006
T200 is a timer used for different control channels specified by the
LAPDm protocol of the BTS. This timer, T200_3, is only used for SACCH
(TCH SAPI0).
Start: When an I frame is sent on SACCH.
Stop: When an RR frame is received from the MS.
At expiry: Check whether the number of times that the timer expires is
equal to N200. If no, the BTS keeps sending the frame before the timer
expiry. If yes, the BTS sends an error report to the BSC, initiates an

Description

exception release process, and changes the status of LAPDm to IDLE.

Managed Object

Cell
1..7

Value Range and Step

Step: 1

Unit

10 ms

Default Value

Default Value
Configuration Reason

The default value is the maximum value recommended by the protocol.


If the parameter value is too small, too much redundant information

Configuration Rule and


Adjustment Suggestion

will be sent.
If the parameter value is too large, the access speed of the MS will be
reduced when the radio environment is bad.
4-98

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.23 Lapdm Timer for controlling SACCH with sdcch channel


(T200_4)
Full Name

Lapdm Timer for controlling SACCH with sdcch channel

Abbreviation

T200_4

3GPP Name

T200

3GPP Reference

3GPP TS44.006
T200 is a timer used for different control channels specified by the
LAPDm protocol of the BTS. This timer, T200_4, is only used for SACCH
(SDCCH).
Start: When an I frame is sent on SACCH.
Stop: When an RR frame is received from the MS.
At expiry: Check whether the number of times that the timer expires is
equal to N200. If no, the BTS keeps sending the frame before the timer
expiry. If yes, the BTS sends an error report to the BSC, initiates an

Description

exception release process, and changes the status of LAPDm to IDLE.

Managed Object

Cell
1..7

Value Range and Step

Step: 1

Unit

10 ms

4-99
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value
Configuration Reason

The default value is the maximum value recommended by the protocol.


If the parameter value is too small, too much redundant information

Configuration Rule and


Adjustment Suggestion

will be sent.
If the parameter value is too large, the access speed of the MS will be
reduced when the radio environment is bad.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.3.24 Lapdm Timer for controlling sdcch sapi3 channel (T200_5)


Full Name

Lapdm Timer for controlling sdcch sapi3 channel

Abbreviation

T200_5

3GPP Name

T200

3GPP Reference

3GPP TS44.006

4-100
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

T200 is a timer used for different control channels specified by the


LAPDm protocol of the BTS. This timer, T200_5, is only used for SACCH
(SAPI3).
Start: When an I frame or SABM frame is sent on SACCH.
Stop: When an RR or UA frame is received from the MS.
At expiry: Check whether the number of times that the timer expires is
equal to N200. If no, the BTS keeps sending the frame before the timer
expiry. If yes, the BTS sends an error report to the BSC, initiates an
Description

exception release process, and changes the status of LAPDm to IDLE.

Managed Object

Cell
1..7

Value Range and Step

Step: 1

Unit

5 ms

Default Value

Default Value
Configuration Reason

The default value is the maximum value recommended by the protocol.


If the parameter value is too small, too much redundant information

Configuration Rule and

will be sent.

Adjustment Suggestion

If the parameter value is too large, the access speed of the MS will be
reduced when the radio environment is bad.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-101
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.3.25 Lapdm Timer for controlling SACCH with TCH sapi3 channel
(T200_6)
Full Name

Lapdm Timer for controlling SACCH with TCH sapi3 channel

Abbreviation

T200_6

3GPP Name

T200

3GPP Reference

3GPP TS44.006
T200 is a timer used for different control channels specified by the
LAPDm protocol of the BTS. This timer, T200_6, is only used for SACCH
(TCH SAPI3).
Start: When an I frame or SABM frame is sent on SACCH.
Stop: When an RR or UA frame is received from the MS.
At expiry: Check whether the number of times that the timer expires is
equal to N200. If no, the BTS keeps sending the frame before the timer
expiry. If yes, the BTS sends an error report to the BSC, initiates an

Description

exception release process, and changes the status of LAPDm to IDLE.

Managed Object

Cell
1..7

Value Range and Step

Step: 1

Unit

10 ms

Default Value

Default Value
Configuration Reason

The default value is the maximum value recommended by the protocol.


If the parameter value is too small, too much redundant information

Configuration Rule and

will be sent.

Adjustment Suggestion

If the parameter value is too large, the access speed of the MS will be
reduced when the radio environment is bad.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic parameters


3
4-102

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4 Optional Parameters


4.4.1 Early class-mark sending control (ECSC)
Full Name

Early class-mark sending control

Abbreviation

ECSC

3GPP Name

Early Classmark Sending Control

3GPP Reference

3GPP TS44.018
According to the GSM specifications, when MS is provided with the
ECSC function that is also supported by the network, the MS will transmit
the appended class mark information (Classmark 3) to the network after
immediate assignment through the "CLASSMARK CHANGE" message
as soon as possible.
ECSC (Early Classmark Sending Control) determines whether the
network supports the sending of early category classmarks. This
parameter information is broadcast to MSs in the cell through RIL3_RR

Description

SYSTEM INFORMATION TYPE3 message.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

Yes

Default Value

Usually a network i dual-frequency, so this function is recommended

Configuration Reason

to be enabled.

Configuration Rule and

the cell is an extended GSM cell and the network supports the ECSC

Adjustment Suggestion

function, "ECSC" should be set as True. Otherwise, it should be set to

If there is another frequency band in the adjacent cell for handover or

"Yes". Otherwise it should be set to "No".


Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

4-103
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.2 IMSI attach/detach allowed (ImsIadAllowed)


Full Name

IMSI attach/detach allowed

Abbreviation

ImsIadAllowed

3GPP Name

ATT

3GPP Reference

3GPP TS44.018
This parameter indicates whether the IMSI (IMSI Attach/Detach Allowed,
ATT) attach/detach. IMSI detach occur when MS reports switch-off or
when the SIM card is taken out from the MS.
The network (normally VLR) marks "Detach" flag in subscriber
information table. Such procedure assists the network to prevent
unnecessary paging broadcast message to MS. Accordingly, the IMSI
Attach process means that the MS reports entering the working status
to the network or the MS checks after the SIM card is re-inserted into
the MS whether the LAI where the MS is located is consistent with
the original one saved. If yes, the IMSI Attach process will be started;
otherwise, the location updating process will be started instead.
The network (normally VLR) marks "Attach" flag in subscriber information
table after the notification about IMSI attach or location area update
has been received.
This parameter is included in "Control channel information" and is used

Description

for RIL3_RR SYSTEM INFORMATION TYPE3 message.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

Yes

4-104
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value

It is better that an MS reports its state at the moment of turning-on or

Configuration Reason

switching-off.

Configuration Rule and

The default value is recommended.

Adjustment Suggestion

This parameter of each cell in a same location area shall be identical.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.3 Cell bar access (CellBarAccess)


Full Name

Cell bar access

Abbreviation

CellBarAccess

3GPP Name

CELL_BAR_ACCESS

3GPP Reference

3GPP TS 23.022
PLMN carriers can determine whether to allow MS to access a specific
cell (for example the cell in test or the cell for absorbing traffic only).
This parameter informs the MSs in a cell through RIL3_RR SYSTEM
INFORMATION TYPE1, 2, 2bis, 3 and 4..
CellBarAccess and CellBarQulify (cell forbidden limit) can be used

Description

together to determine the priorities of cell selection and reselection.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No
4-105

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Normally the access should not be forbidden, otherwise there are

Configuration Reason

special needs.

Configuration Rule and


Adjustment Suggestion

A cell can be accessed by default.


If the access forbidden switch has been turned on, no MS can access
this cell.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.4 Call re-establishment allowed (CallReestablish)


Full Name

Call re-establishment allowed

Abbreviation

CallReestablish

3GPP Name

RE

3GPP Reference

3GPP TS 44.018
This parameter indicates whether to allow call reestablishment. When
a call drop occurs due to radio link failure caused by burst interference
or blind spot of high building, the MS can initiate a call reestablishment
process to resume the call. The network can determine whether the call
reestablishment is allowed by setting this parameter.
This parameter is broadcasted to all MSs in the cell through RIL3_RR

Description

SYSTEM INFORMATION TYPE1, 2, 2bis, 3, and 4 messages.

Managed Object

Cell

Value Range and Step

Yes/No

4-106
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Unit

None

Default Value

No

Default Value
Configuration Reason

Generally, the call reestablishment is not allowed by default because a


long time is needed for reestablishing a call and the subscriber prefers
hook-on instead of waiting for the resume of the call.
The call reestablishment function can improve user experience,

Configuration Rule and


Adjustment Suggestion

but may increase the call drop rate. In addition, subscribers prefer
hook-on instead of waiting for the resume of the call because the call
reestablishment needs a long time. Generally, it is recommended to
disable this function.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.5 Downlink discontinuous transmission allowed (DtxDwlink)


Full Name

Downlink discontinuous transmission allowed

Abbreviation

DtxDwlink

3GPP Name

DTX
3GPP TS 44.018
3GPP TS 48.008

3GPP Reference

3GPP TS 48.058

4-107
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The Discontinuous Transmission (DTX) mode means that the system


does not transmit signals during the speech intermission of the
subscriber conversation. This parameter participates in determining to
use DTX mode in downlink direction.
Actually, using DTX in downlink direction (in CHANNEL ACTIVATION
message and MODE MODIFY message sent to BTS) is determined
together by this parameter and the DTX indication in downlink direction
in ASSIGNMENT REQUEST message and HANDOVER REQUEST
Description

message of MSC.

Managed Object

Cell
Yes: enabled

Value Range and Step

No: disabled

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.


DTX function can lower the BTS power consumption and reduce the
inner system interference.

Configuration Rule and

When MSC forbids the downlink DTX, it is not used no matter how this

Adjustment Suggestion

parameter is set;
When MSC allows the downlink DTX, this parameter determines whether
the downlink DTX is used.

Change Mode

Offline

Related features

ZGO-04-02-003 Discontinuous Transmission Downlink

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-108
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.4.6 Uplink discontinuous transmission (DtxUplinkBcch)


Full Name

Uplink discontinuous transmission

Abbreviation

DtxUplinkBcch

3GPP Name

DTX

3GPP Reference

3GPP TS44.018
The Discontinuous Transmission (DTX) mode means that the system
does not transmit signals during the speech intermission of the
subscriber conversation.
This parameter controls how MS uses the DTX mode. System
broadcasts "RIL3_RR SYSTEM INFORMATION TYPE3" message
to all MSs in the cell. In addition, it may be necessary to notify MSs
of older versions (of the first stage) through the RIL3_RR SYSTEM
INFORMATION TYPE6 message on SACCH. For MSs of newer
versions, the RIL3_RR SYSTEM INFORMATION TYPE6 message
contains Uplink discontinuous transmission. This parameter is one of
the network function parameters.
If both the BTS equipment and TRAU support the DTX mode, set the

Description

parameter to 1 (employ DTX). Otherwise set it to 2 (DTX not allowed).

Managed Object

Cell
0: MS can use DTX;
1: MS should use DTX;

Value Range and Step

2: MS should not use DTC

Unit

None

Default Value

Default Value
Configuration Reason

Enabled by default.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

ZGO-04-02-004 Discontinuous Transmission Uplink

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-109
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.7 Emergency call allowed (EmergencyCall)


Full Name

Emergency call allowed

Abbreviation

EmergencyCall

3GPP Name

Emergency Call allowed

3GPP Reference

44.018
This parameter indicates whether emergency calls are allowed.
Generally, each MS in the GSM network must have a valid Subscriber
Identifier Module (SIM) to use various services in the network. If an MS
has no SIM or the access level of its SIM (one level in the range from
C0 to C9) is disabled by the serving cell (that is, the MS is not allowed
to initiate an access process according to the system information in
the cell), the operator can determine whether to allow the MS to make
Emergency Calls (ECs), such as a call for police.
As one of network function parameters, the EmergencyCall parameter
is broadcasted to all MSs in the cell through RIL3_RR SYSTEM
INFORMATION TYPE1, 2, 2bis, 3, and 4 messages.
No: MSs with an access level in the range from C0 to C9 are not allowed
to make an emergency call. MSs with an access level in the range
from C11 to C15 are not allowed to make an emergency call too if their
access control bit is "T".
Yes: Emergency calls are allowed for all MSs.
The GSM mobile phone specification designates 112 as a universal
emergency phone number. Because the phone numbers for various
emergency services are different in different countries, the 112
emergency call is generally transferred to civil emergency services,
which provides the exact phone numbers for different emergent special
services. It is recommended to set the parameter value to "Yes", that is,

Description

to allow emergency calls.

Managed Object

Cell

Value Range and Step

Yes: Emergency call allowed; No: Emergency call inhibited

Unit

None

4-110
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value

No
In some countries and regions, dialing the emergency phone number

Default Value

can only get the information of emergency services but not the actual

Configuration Reason

emergency services. Therefore, this parameter can be set to "No" to


avoid unnecessary occupation of channels.

Configuration Rule and

Enable or disable the emergency call function according to the

Adjustment Suggestion

requirement of the local operator.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.8 Support Emergency call preemption (EmergCallPreempt)


Full Name

Support Emergency call preemption

Abbreviation

EmergCallPreempt

3GPP Name

None

3GPP Reference

None

4-111
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines whether to forcibly release a subscriber when


no resource is available for an emergency call. If no resource is available
for an emergency call, there are three cases: 1) If a proper channel is
not available during initial access, it is required to add a handling flow for
forcible release, so as to access an emergency call. 2) If a proper channel
is not available during assignment, it is required to modify the handling
flow for forcible release of an emergency call. 3) If no radio resource is
available during handover, it is required to forcibly release a subscriber to
access the emergency call. The value 1 indicates that the system support
forcibly releasing a subscriber in case of an emergency call. The value 0
indicates that the system does not support forcibly releasing a subscriber
Description

in case of an emergency call.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

An emergency call is prior to be accessed.

Configuration Rule and

Enable or disable this function according to the requirements of the

Adjustment Suggestion

local operator.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

None

4-112
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.4.9 Cell bar qualify (CellBarQualify)


Full Name

Cell bar qualify

Abbreviation

CellBarQualify

3GPP Name

CELL_BAR_QUALIFY

3GPP Reference

44.018
For the area with overlapped cells, the operators expect that the an MS
preferably selects some cells (that is, set the parameter CellBarQualify)
according to the capacity, traffic and functional difference of each cell.
CellBarQualify is used to limit cell priority in special cases. Network
broadcasts the parameter information to all MSs in the cell through
RIL3_RR SYSTEM INFORMATION TYPE3 and TYPE4 messages. It is
one of the cell selection parameters.
Select "No" for Cell Bar Access and "No" for Cell bar qualify
(OCellBarQulify), that is, the cell priority is defined as "Normal". An
MS is likely to be expected to preferably enters some types of cells.
Set the priority of this cell type to "Normal", while the priorities of other
cells to "Low". In some cases, such as micro cellular application, and

Description

dual-frequency networking, this setting will not affect the cell reselection.

Managed Object

Cell

Value Range and Step

Yes: low priority; No: normal priority.

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Usually the cell has a normal priority.


Operators can set the priorities of some cells to "Normal", and set some
to "Low". And the "normal" priority cells should be made to take services
as many as possible.

Change Mode

Offline

Related features

ZGB-02-02-007 Cell Selection

Related Parameters

[Cell]CellBarAccess

4-113
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The descriptions of CellBarQualify and CellBarAccess are as follows:


CellBarQualify = 0, CellBarAccess = 0: The cell selection priority is
normal; the cell reselection state is normal;
CellBarQualify = 0, CellBarAccess = 1: The cell selection priority is
Relationship

forbidden; the cell reselection state is forbidden;


CellBarQualify = 1, CellBarAccess = 0: The cell selection priority is low;
the cell reselection state is normal;
CellBarQualify = 1, CellBarAccess = 1: The cell selection priority is low;
the cell reselection state is normal;

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.10 Access class parameter config select (AccConfigSelect)


Full Name

Access class parameter config select

Abbreviation

AccConfigSelect

3GPP Name

None

3GPP Reference

None
This parameter is a user access control switch based on the SIM card
priority.

Description

This switch controls one cell.

Managed Object

Cell
0: disable user access control;
1: start the first set of ACC data as the control parameter for user access;
2: start the second set of ACC data as the control parameter for user
access;
3: start the third set of ACC data as the control parameter for user
access;
4: start the fourth set of ACC data as the control parameter for user

Value Range and Step

access;
4-114

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Unit

None

Default Value

0: Disable

Default Value

In most cases no manual flow control is needed. The switch is turned off

Configuration Reason

by default.

Configuration Rule and

"Manual Flow Control" is applied, so the control parameter can be adjust

Adjustment Suggestion

according to the traffic load.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]UseCellAcc
[BSC]AccessControl
When the user access control is enabled manually, the automatic flow

Relationship

control will be stopped.


When the settings of BSC-level manual access control switch parameter
is different, the system will use the settings of this parameter.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.11 Cell access control support (UseCellAcc)


Full Name

Cell access control support

Abbreviation

UseCellAcc

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the cell-level or BSC-level.

Managed Object

Cell
0: No. The BSC-level AccessControl parameter is valid;

Value Range and Step

1: Yes. The cell-level AccessControl parameter is valid.

4-115
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

1: Yes

Default Value
Configuration Reason

The settings can vary in different cells.

Configuration Rule and


Adjustment Suggestion

If the same strategy is applied in BSC, this parameter can be set "No".

Change Mode

Offline

Related features

None

Related Parameters

[BSC]AccessControl,
[Cell]AccessControl
When this parameter is set to 0, the BSC level AccessControl parameter

Relationship

is valid;
When this parameter is set to 1, the cell level AccessControl parameter
is valid;

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.12 Adopt Precise Paging for Circuit Switched Service


(CsPrecisePag)
Full Name

Adopt Precise Paging for Circuit Switched Service

Abbreviation

CsPrecisePag

3GPP Name

None

3GPP Reference

None
This parameter determines whether exact paging is applied for the CS

Description

service when the last service of a subscriber belongs to this cell.

Managed Object

Cell

4-116
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

In most cases, the BSC switch can be used to control the function of
exact paging. Therefore, the function of exact paging for the cell CS
service is enabled by default.

Configuration Rule and

For the cells with subscribers moving quickly, the function of exact

Adjustment Suggestion

paging can be disabled.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]PrecisePagSupport
Only when the BSC and cell exact paging switches are both enabled,

Relationship

the system can perform exact paging. This function is applicable to


the client.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.4.13 Adopt Precise Paging for Packet Switched Service


(PsPrecisePag)
Full Name

Adopt Precise Paging for Packet Switched Service

Abbreviation

PsPrecisePag

3GPP Name

None

3GPP Reference

None
This parameter determines whether exact paging is applied for the PS

Description

service when the last service of a subscriber belongs to this cell.

4-117
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

In most cases, the BSC switch can be used to control the function of
exact paging. Therefore, the function of exact paging for the cell PS
service is enabled by default.

Configuration Rule and

For the cells with subscribers moving quickly, the function of exact

Adjustment Suggestion

paging can be disabled.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]PrecisePagSupport
Only when the BSC and cell exact paging switches are both enabled,

Relationship

the system can perform exact paging. This function is applicable to


the client.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.4.14 VPC Age Time (VpcAgeTime)


Full Name

VPC Age Time

Abbreviation

VpcAgeTime

3GPP Name

None

3GPP Reference

None

4-118
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

When the time since the last service of a subscriber occurs exceeds the
aging time configured in this parameter, the VPC cell will not be used as a
cell for exact paging. If this parameter is configured to 0, it indicates that
Description

the VPC is valid permanently.

Managed Object

Cell

Value Range and Step

0..65535. The value 0 means always being valid.

Unit

min

Default Value

Default Value

Usually, if no subscriber is found in the new cell, the subscriber must

Configuration Reason

be in the original cell.


Usually, this parameter can be configured to be valid permanently. If

Configuration Rule and

this parameter is configured to another value, the moving speed of

Adjustment Suggestion

subscribers must be taken into consideration. To be specific, the time for


the subscribers to move out of the VPC must be calculated.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.4.15 HBTS proofread support (HBTSScanSupport)


Full Name

HBTS proofread support

Abbreviation

HBTSScanSupport

3GPP Name

None

3GPP Reference

None

4-119
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the HBTS proofread support. The system performs frequency scan on the current network and reports the scanned
signal information according to the radio resource information operators
provided, to finish the selection and setting of adjacent cell parameters,
Description

and frequency of the basestation carrier.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

8001 supports this function. You can enable this function as needed.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]HBTSScanSiteNum

Relationship

If HBTS scan S8001 site number (HBTSScanSiteNum) is set to 0, this


parameter can be configured but invalid.

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.16 RSSI threshold (RSSIThrd)


Full Name

RSSI threshold

Abbreviation

RSSIThrd

3GPP Name

None

4-120
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

3GPP Reference

None
This parameter indicates the RSSI threshold. It should be reasonably set
in order to ensure GSM system capacity and avoid co-frequency interference. The searching of BCCH frequency to be measured and adjacent

Description

cells depends on the RSSI threshold.

Managed Object

Cell
10..120

Value Range and Step

Step: 1

Unit

None

Default Value

100

Default Value
Configuration Reason

Setting of the default value only takes co-frequency interference into


account. The default value is the experience value according to the
formula [(A+X)-C/I]dBm.
If the final sensitivity of S8001 is AdBm, the RSSI threshold is the value

Configuration Rule and

[(A+X)-C/I]dBm (X is the better adjustment parameter after proofreading

Adjustment Suggestion

according to the actual measurement) around the average RSSI


corresponding to the receiving signal power.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]HBTSScanSiteNum

Relationship

If HBTS scan S8001 site number (HBTSScanSiteNum) is set to 0, this


parameter can be configured but invalid.

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.17 Proofread freqband type (GSM1900Support)


Full Name

Proofread freqband type


4-121

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

GSM1900Support

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the GSM1900 frequency band is sup-

Description

ported.

Managed Object

Cell
GSM900/DCS1800/GSM850,

Value Range and Step

0: not support; 1: support

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter is configured according to network frequency planning.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]HBTSScanSiteNum

Relationship

If HBTS scan S8001 site number (HBTSScanSiteNum) is set to 0, this


parameter can be configured but invalid.

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.18 Access Control (AccessControl)


Full Name

Access Control

Abbreviation

AccessControl

4-122
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

3GPP Name

Access Control

3GPP Reference

44.018
All MSs in GSM system have an access class (15 classes in total).
The MSs that are in the class ranging between 0 and 9 are common
ones. The MSs that are in the class ranging between 11 and 15 are
special MSs (no access class 10). Therefore, the system can disable
the MSs with certain access classes to access the cell (for example
during the installation and commissioning or the congestion control).
This information can reach MS inside the cell in RIL3_RR SYSTEM
INFORMATION TYPE1, 2, 2bis, 3 and 4 messages through Access
control. It is also one of the system control parameters.
The degree of congestion for any CCCH or processor overload during
congestion control can be reduced by temporarily prohibiting one type or
multiple types of subscribers from accessing the system (for subscribers
of access levels 0 .. 9). Generally the system shows the following
overload conditions:
RACH overload appears in CCCH LOAD INDICATION message and
BSS processes the information as per GSM08.58 standard.
If AGCH is overloaded, BSS fails to send IMMEDIATE REJECT or
IMMEDIATE ASSIGNMENT messages. BTS reports to BSC through
DELETE INDICATION messages;
Overloaded PCH is reported in CCCH LOAD INDICATION messages.
BSS informs MSC not to conduct access control;
Other types of overload, which can be found in the "OVERLOAD"

Description

message, for example, MTP overload.

Managed Object

Cell

Value Range and Step

0..9, 11..15

Unit

None

Default Value

None

Default Value
Configuration Reason

Usually users are not limited.

Configuration Rule and

Usually the user limitation is configured during the installation

Adjustment Suggestion

commissioning or the congestion control.

Change Mode

Offline

Related features

ZGB-03-01-001 MS Access Control

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

4-123
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.19 Range of HBTS BARANG (HBTSRange)


Full Name

Range of HBTS BARANG

Abbreviation

HBTSRange

3GPP Name

None

3GPP Reference

None
HBTSRangeLow and HBTSRangeHigh are configured and added to
BARANG range. You can configure and add multiple ranges.
HBTSRangeLow: the lower ARFCN in each range; HBTSRangeHigh:
the upper ARFCN in each range.
You can perform such operations as adding or deleting after typing the

Description

BARANG range.

Managed Object

Cell
0..124, 128..251, 512..885, 975..1023

Value Range and Step

Step: 1

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter is configured according to network frequency planning.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]HBTSScanSiteNum

Relationship

If HBTS scan S8001 site number (HBTSScanSiteNum) is set to 0, this


parameter can be configured but invalid.

4-124
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.4.20 Paging Hole Timer (PagHoleTimer)


Full Name

Paging Hole Timer

Abbreviation

PagHoleTimer

3GPP Name

None

3GPP Reference

None
When the paging time since the service is triggered last time does not

Description

beyond the time specified in the timer, start the paging blackhole counter.

Managed Object

Cell

Value Range and Step

1..65535

Unit

Default Value

180

Default Value

In most cases, subscribers will not leave the cell within three minutes

Configuration Reason

after using services in the cell.

Configuration Rule and


Adjustment Suggestion

It is required to configure this parameter according to the moving speed


of subscribers in the cell. The faster the moving speed of subscribers,
the shorter the time and vice versa.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

0
4-125

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.4.21 Mobile Orignated Short Message intercept (MOSmsIntercept)


Full Name

Mobile Orignated Short Message intercept

Abbreviation

MOSmsIntercept

3GPP Name

Null

3GPP Reference

Null
When the parameter is set to 1, the MO short messages will be inter-

Description

cepted.

Managed Object

CELL
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

Generally, the MO short messages need not be intercepted.

Configuration Rule and

Set the parameter to 0 in generally. If the operator requires intercepting

Adjustment Suggestion

the MO short messages, set the parameter to 1.

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No

4-126
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

4.4.22 Mobile Terminated Short Message intercept


(MTSmsIntercept)
Full Name

Mobile Terminated Short Message intercept

Abbreviation

MTSmsIntercept

3GPP Name

Null

3GPP Reference

Null
When the parameter is set to 1, the MT short messages will be inter-

Description

cepted.

Managed Object

CELL
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

Generally, the MT short messages need not be intercepted.

Configuration Rule and

Set the parameter to 0 in generally. If the operator requires intercepting

Adjustment Suggestion

the MT short messages, set the parameter to 2.

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No

4-127
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Optional


Parameters

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

4.4.23 NCC Config Parameter (NccCfgPara)


Full Name

NCC Config Parameter

Abbreviation

NccCfgPara

3GPP Name

None

3GPP Reference

None

Description

NCC Config Parameter

Managed Object

CELL
0-Nonsupport NCC,

Value Range and Step

1-Support NCC

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The NCC function is supported for SDR (V4.11.13) only.


If the serving cell and a neighbor cell of an MS belong to the same
base station, the NCC can integrate the reception of sigals, improving
the call quality.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID-> Optional Params

4-128
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

4.4.24 RxQual Threshlod (RQThreshold)


Full Name

RxQual Threshlod

Abbreviation

RQThreshold

3GPP Name

None

3GPP Reference

None

Description

RxQual Threshlod

Managed Object

CELL
0-bit error rate under 0.2%,1-bit error rate between 0.2%~0.4%,2-bit error
rate between 0.4%~0.8%,3-bit error rate between 0.8%~1.6%,4-bit error
rate between 1.6%~3.2%,5-bit error rate between 3.2%~6.4%,6-bit error

Value Range and Step

rate between 6.4%~12.8%,7-bit error rate over 12.8%

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The NCC function is supported for SDR (V4.11.13) only.


The value should be no greater than the quality threshold specified for
a handover. If the RQ reported by an MS is larger than this parameter
value, the NCC function is enabled for optimization.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID-> Optional Params

Parameter Modifying
Version

iBSCV6.20.712a
4-129

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

4.4.25 TCH Allocation Threshold For Dual-Frequency Network


(DualFreqNetTchThs)
Full Name

TCH Allocation Threshold For Dual-Frequency Network

Abbreviation

DualFreqNetTchThs

3GPP Name

None

3GPP Reference

None

Description

TCH Allocation Threshold For Dual-Frequency Network

Managed Object

CELL

Value Range and Step

0..100

Unit

Default Value

50

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

Only when the traffic load of the local cell reaches a certain level can
a directed retry be performed to transfer traffic to the dual-frequency
network associated cell.
If the local cell encounters large interference, reduce this threshold, and
a directed retry is performed to transfer services to the dual-frequency
network associated cell.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID->Optional Params

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

4-130
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.4.26 Diversity Combine Mode (DivCombMode)


Full Name

Diversity Combine Mode

Abbreviation

DivCombMode

3GPP Name

None

3GPP Reference

None

Description

Diversity Combine Mode

Managed Object

CELL

Value Range and Step

0-MRC,1-IRC,2-EIRC

Unit

None

Default Value

Default Value
Configuration Reason

The anti-interference performance of the IRC is best.


If the co-frequency interference is restricted, use the Enhanced RIC

Configuration Rule and


Adjustment Suggestion

(EIRC).
In other cases, select the Interference Rejection Combining (IRC)
function.

Change Mode

Offline
ZGO-04-01-005 Interference Rejection Combining (IRC)

Related features

ZGO-04-01-009 Enhanced IRC

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID-> Optional Params

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

4.4.27 SubCell Channel Allocation Parameter (CSAllocSC)


Full Name

SubCell Channel Allocation Parameter


4-131

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

CSAllocSC

3GPP Name

None

3GPP Reference

None

Description

Sets the preferred cell for the channel allocation process.

Managed Object

CELL
0~1
0: SubCell2 as Preferred Channel Allocation SubCell

Value Range and Step

1: SubCell1 as Preferred Channel Allocation SubCell

Unit

None

Default Value

0 SubCell2 as Preferred Channel Allocation SubCell

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID-> Optional Params

Parameter Modifying
Version

iBSCV6.20.713a

Parameter Modifying
Detail

NEW

4.4.28 Is Enhanced Dual-Frequency Network Support


(IsDualFreqSup)
Full Name

Is Enhanced Dual-Frequency Network Support

Abbreviation

IsDualFreqSup

3GPP Name

None
4-132

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

3GPP Reference

None

Description

Sets whether to enable enhanced dual-frequency network.

Managed Object

CELL

Value Range and Step

0: No, 1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID-> Optional Params

Parameter Modifying
Version

iBSCV6.20.713a

Parameter Modifying
Detail

NEW

4.5 Cell Selection Parameters


4.5.1 the maximum thresholds of Utran reselection
(UtranHighThresh)
Full Name

the maximum thresholds of Utran reselection

Abbreviation

UtranHighThresh

3GPP Name

THRESH_UTRAN_high

3GPP Reference

3GPP TS 44018 V8.9.0

4-133
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines the maximum signal difference when an MS


Description

is reselected to the adjacent UTRAN cell.

Managed Object

Cell

Value Range and Step

0-31; 0 = 0 dB, 1 = 2 dB, 2 = 4 dB, 3 = 6 dB, .., 30 = 60 dB, 31 = 63 dB

Unit

dB

Default Value

26, 24, 22, 20, 18, 16, 14, 12

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to signal strength

Adjustment Suggestion

in the on-site environment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.2 the minimum thresholds of Utran reselection


(UtranLowThresh)
Full Name

the minimum thresholds of Utran reselection

Abbreviation

UtranLowThresh

3GPP Name

THRESH_UTRAN_low

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the minimum signal difference when an MS is

Description

reselected to the adjacent UTRAN cell.

Managed Object

Cell
4-134

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Value Range and Step

0-31; 0 = 0 dB, 1 = 2 dB, 2 = 4 dB, 3 = 6 dB, .., 30 = 60 dB, 31 = 63 dB

Unit

dB

Default Value

26, 24, 22, 20, 18, 16, 14, 12

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to signal strength

Adjustment Suggestion

in the on-site environment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.3 Minimum RX level for Utran cells (UtranQRXLEVMIN)


Full Name

Minimum RX level for Utran cells

Abbreviation

UtranQRXLEVMIN

3GPP Name

UTRAN_QRXLEVMIN

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the minimum signal when an MS is reselected

Description

to the adjacent UTRAN cell.

Managed Object

Cell
0-31; 0 = -140 dBm, 1 = -138 dBm, 2 = -136 dBm, .., 30 = -80 dBm, 31 =

Value Range and Step

-79 dBm

Unit

dBm

Default Value

0
4-135

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

It is required to configure this parameter according to the recommended

Configuration Reason

protocol value.

Configuration Rule and

It is required to configure this parameter according to signal strength

Adjustment Suggestion

in the on-site environment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.4 The maximum thresholds of EUtran reselection


(EUtranHighThresh)
Full Name

The maximum thresholds of EUtran reselection

Abbreviation

EUtranHighThresh

3GPP Name

THRESH_E-UTRAN_high

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the maximum signal difference when an MS

Description

is reselected to the adjacent EUTRAN cell.

Managed Object

Cell

Value Range and Step

0-31; 0 = 0 dB, 1 = 2 dB, 2 = 4 dB, 3 = 6 dB, .., 30 = 60 dB, 31 = 63 dB

Unit

dB

Default Value

26, 24, 22, 20, 18, 16, 14, 12

Default Value
Configuration Reason

None

4-136
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Configuration Rule and

It is required to configure this parameter according to signal strength

Adjustment Suggestion

in the on-site environment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.5 The minimum thresholds of EUtran reselection


(EUtranLowThresh)
Full Name

The minimum thresholds of EUtran reselection

Abbreviation

EUtranLowThresh

3GPP Name

THRESH_E-UTRAN_low

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the minimum signal difference when an MS is

Description

reselected to the adjacent EUTRAN cell.

Managed Object

Cell

Value Range and Step

0-31; 0 = 0 dB, 1 = 2 dB, 2 = 4 dB, 3 = 6 dB, .., 30 = 60 dB, 31 = 63 dB

Unit

dB

Default Value

26, 24, 22, 20, 18, 16, 14, 12

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to signal strength

Adjustment Suggestion

in the on-site environment.

Change Mode

Offline
4-137

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.6 Minimum RX level for EUtran cells (EUtranQRXLEVMIN)


Full Name

Minimum RX level for EUtran cells

Abbreviation

EUtranQRXLEVMIN

3GPP Name

E-UTRAN_QRXLEVMIN

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the minimum signal when an MS is reselected

Description

to the adjacent EUTRAN cell.

Managed Object

Cell
0-31; 0 = -140 dBm, 1 = -138 dBm, 2 = -136 dBm, .., 30 = -80 dBm, 31 =

Value Range and Step

-79 dBm

Unit

dBm

Default Value

Default Value

It is required to configure this parameter according to the recommended

Configuration Reason

protocol value.

Configuration Rule and

It is required to configure this parameter according to signal strength

Adjustment Suggestion

in the on-site environment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None
4-138

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.7 The maximum RSRQ thresholds for EUtran reselection


(EUtranHighThreshQ)
Full Name

The maximum RSRQ thresholds for EUtran reselection

Abbreviation

EUtranHighThreshQ

3GPP Name

None

3GPP Reference

None

Description

High RSRQ thresholds for EUtran reselection

Managed Object

CELL
0..31

Value Range and Step

0 = 0 dB, 1 = 1 dB, 2 = 2 dB, 3 = 3 dB, , 30 = 30 dB, 31 = 31 dB.

Unit

dB

Default Value

26,24,22,20,18,16,14,12

Default Value
Configuration Reason

Consistent with the parameter EUtranHighThresh.

Configuration Rule and


Adjustment Suggestion

Consistent with EUtranHighThresh.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

0
4-139

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set

OMC Access Path

ID->BSC Function ID->Site config->Site ID->Cell ID->Cell Selection


Parameters

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

4.5.8 The minimum RSRQ thresholds of EUtran reselection


(EUtranLowThreshQ)
Full Name

The minimum RSRQ thresholds of EUtran reselection

Abbreviation

EUtranLowThreshQ

3GPP Name

None

3GPP Reference

None

Description

Low RSRQ thresholds for EUtran reselection

Managed Object

CELL
0..31

Value Range and Step

0 = 0 dB, 1 = 1 dB, 2 = 2 dB, 3 = 3 dB, , 30 = 30 dB, 31 = 31 dB.

Unit

dB

Default Value

26,24,22,20,18,16,14,12

Default Value
Configuration Reason

Refer to the parameter EUtranHighThresh.

Configuration Rule and


Adjustment Suggestion

Refer to the parameter EUtranLowThresh.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
4-140

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


OMC Access Path

ID->BSC Function ID->Site config->Site ID->Cell ID->Cell Selection


Parameters

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

4.5.9 Minimum RSRQ for EUtran cells (EUtranQQUALMIN)


Full Name

Minimum RSRQ for EUtran cells

Abbreviation

EUtranQQUALMIN

3GPP Name

None

3GPP Reference

None

Description

Minimum RSRQ of EUtran cells

Managed Object

CELL
0-15
0= -34dB, 1= -32dB, 2= -30dB, , 14= -6dB, 15= -4dB.

Value Range and Step

-34+n*2

Unit

dB

Default Value

0,-34db

Default Value
Configuration Reason

Refer to the parameter EUtranQUALMIN.

Configuration Rule and


Adjustment Suggestion

Refer to the parameter EUtranQUALMIN.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set

OMC Access Path

ID->BSC Function ID->Site config->Site ID->Cell ID->Cell Selection


Parameters
4-141

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

4.5.10 Additional reselection parameter indication (AdditionReselPI)


Full Name

Additional reselection parameter indication

Abbreviation

AdditionReselPI

3GPP Name

None

3GPP Reference

None
The cell selection and reselection of MS depends on the C1 and C2
parameters, according to the definition in the GSM specifications.
Network carriers decide whether to use C2 as the cell reselection
parameter.Additional reselection parameter indication is to notify MS
whether C2 criterion is adoptable during the cell reselection.
Network broadcasts the parameter information to MS in the cell through
RIL3_RR SYSTEM INFORMATION TYPE3 and TYPE4 messages.
Additional reselection parameter indication is one of the cell selection
parameters.Value Instruction:
Yes: MS takes off cell reselection parameter PI and the parameters
related to computing C2 from the rest bytes (SI7/8 Rest Octets) of
SYSTEM INFORMATION TYPE 4.
No: MS shall obtain the PI parameter related to the cell reselection and
parameters related to the C2 calculation from the rest bytes (SI7/8 Rest
Octets) of the SYSTEM INFORMATION TYPE7 or 8 message.
Generally, the system messages 7 and 8 are seldom used. Normally this
parameter is No. It shall be Yes when the system adopts the system

Description

messages 7 and 8, and the cell reselection uses C2.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The default value is subject to the on-site reselection policies. Generally,

Configuration Reason

it does not adopt SI7 and SI8.

Configuration Rule and

Generally, the system messages 7 and 8 are seldom used. Normally the

Adjustment Suggestion

parameter AdditionReselPI is No.

Change Mode

Offline

Related features

None
4-142

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.11 Cell reselection parameter indication (CellReselPI)


Full Name

Cell reselection parameter indication

Abbreviation

CellReselPI

3GPP Name

None

3GPP Reference

None
This parameter notifies the MS whether to use C2 as the cell reselection
parameter and if there is the related parameter for calculating C2.
It indicates whether the related parameter for calculating cell reselection
standard C2 is contained in SYSTEM INFORMATION message and
whether C2 standard is adopted in the cell reselection. The successive
Cell reselection offset, Temporary offset and Penalty time are invalid,
and MS takes C1 as the cell reselection standard when this value is No.
This parameter is broadcasted to all MS in the cell in RIL3_RR
SYSTEM INFORMATION TYPE3 and TYPE4 messages.Cell reselection
parameter indication is one of the cell selection parameters.Value
Instruction:
Yes: MS gets parameters to compute C2 from cell broadcast system
messages and regard C2 as a cell reselection standard. Parameters
Cell bar qualify, Cell reselection offset, Temporary offset and Penalty
time are invalid.
No: MS considers C1 parameter as a cell reselection standard.
Parameters Cell bar qualify, Cell reselection offset, Temporary offset

Description

and Penalty time are invalid.

4-143
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Enable this parameter, if related cell adopts C2 as the cell reselection


standard. Otherwise, disable it.
Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The default value is subject to the on-site reselection policies. Generally,

Configuration Reason

C2 algorithm is not enabled.


In the scenario with dual-frequency network of dense urban area/urban

Configuration Rule and


Adjustment Suggestion

area, it is suggested to enable C2 algorithm of 1800 M to balance the


traffic.For 900 M cell, this parameter is subject to the traffic and actual
configurations.Cell reselection parameter indication should be enabled
when CBA or CBQ is enabled in the cell.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]CellBarQualify
[Cell]ReselOffset
[Cell]TemporaryOffset
[Cell]PenaltyTime

Relationship

Parameters Cell bar qualify, Cell reselection offset, Temporary offset and
Penalty time are valid till cell reselection parameter indication is enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.12 Cell reselection offset (ReselOffset)


Full Name

Cell reselection offset

Abbreviation

ReselOffset

4-144
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

3GPP Name

CELL_RESELECT_OFFSET

3GPP Reference

3GPP TS 45.008 V5.22.0


The cell reselection caused by the radio channel quality takes C2 as the
standard. C2 is based on parameter C1 plus some man-made offset
parameters. The human factor is to encourage MS to enter some cells in
priority, or to block MS from entering some cells. Usually, such measures
are all adopted to balance traffic in the network.
Besides C1, there are three factors affecting C2: Cell reselection offset,
Temporary offset, and Penalty time.
Cell reselection offset is a magnitude value, which indicates the human
modified value of C2. Calculate a modified value of C2 to encourage or
prevent MS accessing a certain cell, so as to balance the network.
Network broadcasts the parameter information to all MSs in the cell
through RIL3_RR SYSTEM INFORMATION TYPE3 and TYPE4
messages. It is one of the cell selection parameters. The validity of this
parameter depends upon Cell reselection parameter indication.
The settings of Cell reselection offset, Temporary offset and the Penalty
time are classified into three cases:
In case of large traffic or poor communication quality inside a cell due
to certain causes, normally MS is expected not to work in that cell (that
is, certain repulsion to that cell).
Penalty time can be set as 31in such cases. Temporary offset is invalid,
and the numerical value of C2 equals C1 minus this parameter Cell
reselection offset. Therefore, the C2 value corresponding to the cell is
decreased, and the possibility that MS reselects the cell is reduced.
Besides, the proper value of this parameter Cell reselection offset can be
set according to the repulsive nature of cell. The more is the repulsive
nature, the larger is the Cell reselection offset. Vice versa in case of
a smaller Cell reselection offset.
For the cell with small traffic and low equipment utilization, normally MS
is encouraged to work in that cell (that is, certain propensity to that cell).
Cell reselection offset must be set between 0 ~ 10 (corresponding to
0 ~ 20 dB) in this case, according to tendency of the cell. The more
is the tendency, the larger is the Cell reselection offset. Vice versa in
case of a smaller Cell reselection offset. It is usually better to set the
Temporary offset same as Cell reselection offset, or a little higher than
Cell reselection offset. The main function of Penalty time is to avoid
frequent cell reselection of MS. The common recommended setting is 1
(20 seconds) or 2 (40 seconds) (the 1800 cell of dual-frequency network
is such a case).
Cell reselection offset is set as 0 and Penalty time as 31 for cells with
ordinary traffic. C2 is equal to C1, that is, without human factors on

Description

the cell.

4-145
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell
0 .. 63

Value Range and Step

Step: 1

Unit

2 dB

Default Value

Default Value
Configuration Reason

Usually, the default value is 0, and C2 is not enabled.


In the scenario with dual-frequency network in dense urban area/urban
area, it is better to set CRO for 1800M cell to 4..8. In the scenario with
dual-frequency in the suburb, it is better to O set CRO for 1800M cell
to 0..5. The settings of CRO, TO, and PT are:
MS is expected not to be in the cell (that is, certain repulsion to that cell)
with large traffic or poor communication quality due to certain causes.
Penalty time can be set as 31in such cases. Temporary offset is
invalid, and the numerical value of C2 equals C1 minus this parameter
Cell reselection offset. Therefore, the C2 value corresponding to the
cell is decreased, and the possibility that MS reselects the cell is
reduced.Besides, the proper value of this parameter Cell reselection
offset can be set according to the repulsive nature of cell. The more is
the repulsive nature, the larger is the Cell reselection offset. Vice versa
in case of a smaller Cell reselection offset.

Configuration Rule and


Adjustment Suggestion

MS is usually encouraged to be in the cell (that is, certain propensity to


that cell) with small traffic and low equipment utilization.
Cell reselection offset must be set between 0 ~ 10 (corresponding to
0 ~ 20 dB) in this case, according to tendency of the cell. The more
is the tendency, the larger is the Cell reselection offset. Vice versa in
case of a smaller Cell reselection offset. It is usually better to set the
Temporary offset same as Cell reselection offset, or a little higher than
Cell reselection offset. The main function of Penalty time is to avoid
frequent cell reselection of MS. The common recommended setting is 1
(20 seconds) or 2 (40 seconds) (the 1800 cell of dual-frequency network
is such a case).
The terminal will select the cell with low DL level if CRO is too large.
Consequently, coverage test rate decreases.
After the CRO is set, the traffic can be reasonably absorbed or repulsed,
SD/TCH congestion rate can be effectively reduced, and paging setup
success rate can be improved.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None
4-146

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.13 Temporary offset (TemporaryOffset)


Full Name

Temporary offset

Abbreviation

TemporaryOffset

3GPP Name

TEMPORARY_OFFSET

3GPP Reference

3GPP TS 45.008 V5.22.0


The cell reselection caused by the radio channel quality takes C2 as the
standard. C2 is based on parameter C1 plus some man-made offset
parameters. The human factor is to encourage MS to enter some cells in
priority, or to block MS from entering some cells. Usually, such measures
are all adopted to balance traffic in the network.
Besides C1, there are three factors affecting C2: Cell reselection offset,
Temporary offset, and Penalty time.Temporary offset indicates the
temporary modification value for C2. Temporary means that it only acts
on C2 for a period and the period depends on parameter Penalty time.
Network broadcasts the parameter information to all MSs in the cell
through RIL3_RR SYSTEM INFORMATION TYPE3 and TYPE4
messages. It is one of the cell selection parameters. The validity of this

Description

parameter depends upon Cell reselection parameter indication.

Managed Object

Cell
0 .. 7

Value Range and Step

Step: 1

Unit

10 dB

Default Value

Default Value
Configuration Reason

The default value is appropriately offset within a certain penalty time.

4-147
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and

It is suggested to set the parameter to 1. The parameter is appropriately

Adjustment Suggestion

offset within a certain penalty time to avoid frequent reselection.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.14 Penalty time (PenaltyTime)


Full Name

Penalty time

Abbreviation

PenaltyTime

3GPP Name

PENALTY_TIME

3GPP Reference

3GPP TS 45.008 V5.22.0


The cell reselection caused by the radio channel quality takes C2 as the
standard. C2 is based on parameter C1 plus some man-made offset
parameters. The human factor is to encourage MS to enter some cells in
priority, or to block MS from entering some cells. Usually, such measures
are all adopted to balance traffic in the network.
Besides C1, there are three factors affecting C2: Cell reselection offset,
Temporary offset, and Penalty time.Temporary offset indicates the
temporary modification value for C2. Temporary means that it only acts
on C2 for a period and the period depends on parameter Penalty time.
Network broadcasts the parameter information to all MSs in the cell
through RIL3_RR SYSTEM INFORMATION TYPE3 and TYPE4
messages. It is one of the cell selection parameters. The validity of this

Description

parameter depends upon Cell reselection parameter indication.

4-148
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Managed Object

Cell
0 .. 31

Value Range and Step

Step: 1

Unit

20 s

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Usually, the default value is 0, and C2 is not enabled.


It is suggested to set this parameter as 0 indicating 20s. The value is
only used in traffic balance conditions when it is set to 31 and CRO
is a negative value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.15 Cell reselecting hysteresis level (ReselHysteresis)


Full Name

Cell reselecting hysteresis level

Abbreviation

ReselHysteresis

3GPP Name

CELL_RESELECT_HYSTERESIS

3GPP Reference

3GPP TS 45.008 V5.22.0

4-149
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

When MS reselects a cell, if the original cell and destination cell belong
to different location areas, MS should initialize a location updating
process after cell reselection.
C2 values obtained at the boundary for two adjacent cells are different
due to fading characteristic of radio channel. Consequently, MS selects
cell frequently. The interval between the two cell reselections of MS
is not less than 15 s. However, 15 s is extremely short time in terms
of location updating.
This increases the signaling flow on the network and causes radio
resources to be not fully utilized. In addition, it decreases call completion
rate of the system, as MS cannot respond to paging during location
update.
The GSM specifications set a specific parameter, Cell Reselecting
Hysteresis (CRH), to solve this problem. MS will activate the cell
reselection according to this parameter only when the signal level of
adjacent cell (whose location area is different from that of local cell) is
greater than that of local cell, and meanwhile the value difference must
be greater than that required by the parameter.
Network broadcasts the parameter information to MS in the cell through
RIL3_RR SYSTEM INFORMATION TYPE3 and TYPE4 messages. Cell
reselecting hysteresis level is one of the cell selection parameters.
Define Cell reselecting hysteresis level to 4 or 5 (that is, 8 dB or 10 dB
for CRH level) and make certain adjustments in following cases:
Increase cell reselection parameters of adjacent cells with different
LACs. Signaling traffic overload often occurs due to large demand
of services.
Increase cell reselection parameters if adjacent cells belonging to
different location areas with wide coverage range.
If the adjacent cells with different LACs are poor in overlapped coverage,
that is, there is coverage gap, or the adjacent place is an area with
few slow moving objects such as the expressway, the CRH parameter
Description

should be set to 1..3 (that is, 2dB..6dB for the CRH level).

Managed Object

Cell
0 .. 7

Value Range and Step

Step: 1

Unit

2 dB

Default Value

Default Value

The default value is set to a value with certain hysteresis, so as to avoid

Configuration Reason

frequent cross-LAC reselection.

4-150
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

It is recommended to set this value for cross-LAC cells to a relatively


large value, so as to reduce large amount of location updates due to
frequent reselection.If the parameter is set to a relatively large value,
Configuration Rule and

number of PS reselection times in the ready status can be reduced and

Adjustment Suggestion

the rate can be improved;


If CRH value is increased in the cross-LAC cell, location updates can be
reduced, SD channel congestion rate can be reduced, and call set-up
success rate can be improved.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.16 New setup cause indication (NECI)


Full Name

New setup cause indication

Abbreviation

NECI

3GPP Name

NECI

3GPP Reference

3GPP TS44.018 V5.22.0

4-151
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

According to with the GSM specification, the serving channels in the


GSM system can be classified into channels with full rate and channels
with half rate according to the GSM specifications. Common GSM
system supports the channels with full rate. The network operators
decide whether the network supports half-rate services.NECI (new setup
cause indication) is to notify the MS whether the area supports half-rate
services (half-rate services are not influenced, though NECI is not
enabled) and affects the meaning of channel request cause value and
the selection of initial channel types. This parameter notifies the MS
through the RIL3_RR SYSTEM INFORMATION TYPE3 and TYPE4
Description

messages. It is one of the network function parameters.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

The default is disabled due to there is no half rate on site by default.

Configuration Rule and

It is suggested to require for half rate application. This parameter can

Adjustment Suggestion

be set as "Yes".

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-152
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.5.17 Power offset indication (PowerOffsetInd)


Full Name

Power offset indication

Abbreviation

PowerOffsetInd

3GPP Name

None

3GPP Reference

None
For the Class 3 MS of GSM1800, the transmission power for sending an
access request message on the RACH channel is to add an offset value
on the basis of MsTxPwrMaxCCH value. The necessity of the offset
value depends on the parameter PwrOffsetInd.
This parameter information is broadcast to the MS in the cell through the

Description

RI_RR SYSTEM INFORMATION TYPE, 4, 7 and 8 messages.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

Class 3 MSs of GSM1800 are rare, so it is suggested to keep the default

Configuration Reason

value.

Configuration Rule and

Class 3 MSs of GSM1800 are rare, so it is suggested to keep the default

Adjustment Suggestion

value.

Change Mode

Offline

Related features

ZGB-02-02-007 Support of C1 Criteria

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-153
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.5.18 Power offset (PowerOffset)


Full Name

Power offset

Abbreviation

PowerOffset

3GPP Name

POWER OFFSET

3GPP Reference

3GPP TS 45.008 V5.22.0


GSMAccording to the GSM specifications, for Class 3 MS of GSM 1800,
the transmission power for sending access request message on RACH
is to add an offset alue on the basis of MsTxPwrMaxCCH value. This
parameter specifies the modified value. The necessity of the modified
value is specified by the parameter PwrOffsetInd, that is, the parameter
PwrOffsetInd decides whether this parameter is valid.
This parameter also affects the calculation of cell selection standard
C1 and cell reselection standard C2. This parameter information
is broadcast to the MS in the cell through the RIL3_RR SYSTEM

Description

INFORMATION TYPE3, 4, 7 and 8 messages.

Managed Object

Cell
0 .. 3

Value Range and Step

Step: 1

Unit

2 dB

Default Value

Default Value

Class 3 MSs of GSM1800 are rare, so it is suggested to keep the default

Configuration Reason

value.

Configuration Rule and

Class 3 MSs of GSM1800 are rare, so it is suggested to keep the default

Adjustment Suggestion

value.

Change Mode

Offline

Related features

ZGB-02-02-007 Support of C1 Criteria

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None
4-154

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

None

4.5.19 Based on priority Cell re-selection Switch (PrioReselSupport)


Full Name

Based on priority Cell re-selection Switch

Abbreviation

PrioReselSupport

3GPP Name

None

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines whether to enable cell reselection based on

Description

priority.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and

When reselecting an adjacent LTE cell, enable this switch. In other

Adjustment Suggestion

cases, disable this switch.

Change Mode

Offline

Related features

None

Related Parameters

EUtran Neighbour Cell,Utran Neighbour Cell


When an adjacent LTE cell exists, it is required to enable the

Relationship

PrioReselSupport switch. When the PrioReselSupport switch is enabled,


an adjacent LTE or 3G cell must exist.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-155
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.5.20 Priority of GSM cells (ServCellPrio)


Full Name

Priority of GSM cells

Abbreviation

ServCellPrio

3GPP Name

GERAN_PRIORITY

3GPP Reference

3GPP TS 44018 V8.9.0

Description

This parameter determines the priority of a GSM cell.

Managed Object

Cell

Value Range and Step

0-7; 0 = lowest priority, .., 7 = highest priority

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to the priority of the

Adjustment Suggestion

adjacent cell.

Change Mode

Offline

Related features

None

Related Parameters

UtranDefaultPrio,EUtranDefaultPrio

Relationship

The value of ServCellPrio cannot be the same as that of UtranDefaultPrio


or EUtranDefaultPrio.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.21 Threshold of serving cell that used by priority Cell


re-selection algorithm (THRESHPRIORYSEARCH)
Full Name

Threshold of serving cell that used by priority Cell re-selection algorithm

4-156
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Abbreviation

THRESHPRIORYSEARCH

3GPP Name

THRESH_Priority_Search

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the threshold of the priority-based cell rese-

Description

lection algorithm.

Managed Object

Cell
0-15; 0 = -98 dBm, 1 = -95 dBm, 2 = -92 dBm, .., 13 = -59 dBm, 14 = -56

Value Range and Step

dBm, 15 = (always).

Unit

dBm

Default Value

15

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to the on-site

Adjustment Suggestion

environment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.22 Threshold that Allow MS re-select to lower priority Cell


(THRESHGSMLOW)
Full Name

Threshold that Allow MS re-select to lower priority Cell

Abbreviation

THRESHGSMLOW

3GPP Name

THRESH_GSM_low
4-157

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the threshold used when the MS is reselected

Description

to a cell with low priority.

Managed Object

Cell
0-15; 0 = -98 dBm, 1 = -95 dBm, 2 = -92 dBm, .., 13 = -59 dBm, 14 = -56

Value Range and Step

dBm, 15 = (always).

Unit

dBm

Default Value

15

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to the on-site

Adjustment Suggestion

environment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.23 Hysteresis of priority reselection algorithm


(HysteresisofPRiority)
Full Name

Hysteresis of priority reselection algorithm

Abbreviation

HysteresisofPRiority

3GPP Name

H_PRIO

3GPP Reference

3GPP TS 44018 V8.9.0

Description

This parameter determines the delay of the reselection algorithm.


4-158

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Managed Object

Cell

Value Range and Step

0..3; 0 = (rule disabled), 1 = 5 dB, 2 = 4 dB, 3 = 3 dB

Unit

dB

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to the on-site

Adjustment Suggestion

environment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.24 Time hysteresis of priority reselection algorithm


(TimeHysteresisofReS)
Full Name

Time hysteresis of priority reselection algorithm

Abbreviation

TimeHysteresisofReS

3GPP Name

T_Reselection

3GPP Reference

3GPP TS 44018 V8.9.0

Description

This parameter determines the delay time of the reselection algorithm.

Managed Object

Cell

Value Range and Step

0..3; 0 = 5 sec, 1 = 10 sec, 2 = 15 sec, 3 = 20 sec

Unit

4-159
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to the on-site

Adjustment Suggestion

environment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.25 The default priority of Utran Cells (UtranDefaultPrio)


Full Name

The default priority of Utran Cells

Abbreviation

UtranDefaultPrio

3GPP Name

DEFAULT_UTRAN_PRIORITY

3GPP Reference

3GPP TS 44018 V8.9.0

Description

This parameter determines the default priority of a UTRAN cell.

Managed Object

Cell

Value Range and Step

0-7; 0 = lowest priority, .., 7 = highest priority

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

Currently, this parameter is being developed and thus requires no

Adjustment Suggestion

adjustment.
4-160

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Change Mode

Offline

Related features

None

Related Parameters

ServCellPrio

Relationship

The value of UtranDefaultPrio cannot be the same as that of


ServCellPrio.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.5.26 The default priority of EUtran Cells (EUtranDefaultPrio)


Full Name

The default priority of EUtran Cells

Abbreviation

EUtranDefaultPrio

3GPP Name

None

3GPP Reference

3GPP TS 44018 V8.9.0

Description

This parameter determines the default priority of a EUTRAN cell.

Managed Object

Cell

Value Range and Step

0-7; 0 = lowest priority, .., 7 = highest priority

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

Currently, this parameter is being developed and thus requires no

Adjustment Suggestion

adjustment.

Change Mode

Offline

Related features

None

Related Parameters

ServCellPrio

4-161
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

The value of EUtranDefaultPrio cannot be the same as that of


ServCellPrio.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Selection


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6 Service Process Additional Parameters


4.6.1 Directed retry indication (DrInd_0)
Full Name

Directed retry indication

Abbreviation

DrInd_0

3GPP Name

None

3GPP Reference

None
This parameter indicates whether to support the directed retry. During
an assignment process, if a serving cell has no service channel for
assignment, the system can initiate a directed retry to assign a service
channel in the neighbour cell to the MS according to the measurement
report received from the MS.
Directed retry is a special handover process, which can reduce the MS
access failure rate. Directed retry can be categorized into intra-BSC
directed retry and inter-BSC directed retry. Intra-BSC directed retry does

Description

not need the support of the MSC; while the inter-BSC one does.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

4-162
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

It is recommended to enable the directed retry in areas with heavy traffic.

Change Mode

Offline

Related features

ZGB-03-01-002 Direct Retry

Related Parameters

[Cell]DrInd_1
[BSC]InDrEnable
When this parameter is set to "Yes", the "DrInd_1" parameter can be set.

Relationship

The directed retry function is enabled only when the BSS-level directed
retry (InDrEnable) and the cell-level directed retry are both enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.2 External directed retry indication (DrInd_1)


Full Name

External directed retry indication

Abbreviation

DrInd_1

3GPP Name

None

3GPP Reference

None
This parameter indicates whether to enable the external directed retry,

Description

that is, inter-BSC directed retry.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

4-163
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

It is recommended to enable the external directed retry in areas with

Adjustment Suggestion

heavy traffic on the coverage border of the iBSC.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]DrInd_0
[BSC]OutDrEnable
The parameter can only be set when the "DrInd_0" parameter is set

Relationship

to "Yes".
The external directed retry can be enabled only when this parameter and
the OutDrEnable parameter are both enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.3 Queue allowed when assign (QueueInd_0)


Full Name

Queue allowed when assign

Abbreviation

QueueInd_0

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow queuing during assignments

Description

when no available channel exists in the cell.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

4-164
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


This switch is only enabled when the queuing function is required on site.

Configuration Rule and


Adjustment Suggestion

If this switch is enabled, an assignment process can obtain resources by


queuing to improve the call completion rate when no available resource
exists in the system. However, the time for completing a call may be
prolonged.

Change Mode

Offline

Related features

ZGB-03-01-003 Queuing

Related Parameters

[BSC]QueueIndAss
[BSC]AssQueEnable
Two BSC-level parameters are related to this parameter: QueueIndAss

Relationship

and AssQueEnable. The queuing is allowed only when these three


parameters are enabled at the same time.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.4 Queue allowed when handover (QueueInd_1)


Full Name

Queue allowed when handover

Abbreviation

QueueInd_1

3GPP Name

None

3GPP Reference

None

Description

when no available channel exists in the cell.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

This parameter determines whether to allow queuing during handovers

4-165
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


This switch is only enabled when the queuing function is required on site.
If this switch is enabled, an external handover process can obtain
resources by queuing when no available resource exists in the system.

Change Mode

Offline

Related features

ZGB-03-01-003 Queuing

Related Parameters

[BSC]QueueIndHo
[BSC]HoQueEnable
Two BSC-level parameters are related to this parameter: QueueIndHo

Relationship

and HoQueEnable. The queuing is allowed only when these three


parameters are enabled at the same time.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.5 Preemption allowed when assign (PreemptionInd_0)


Full Name

Preemption allowed when assign

Abbreviation

PreemptionInd_0

3GPP Name

Internal

3GPP Reference

None

4-166
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter indicates whether to allow forced release during assignments. The MSC sends the priority parameters (including priority level,
PCI, and PVI) to the BSC through an assignment command message.
If this message contains a high priority level and a valid PCI (indicating
this user can preempt the channel of another user), the BSC can forcibly
release the connection to a user whose PVI is reset (indicating the channel of this user can be preempted by another user) and then allocate the
released channel on this assignment request when no resource is immeDescription

diately assigned to the higher-priority user.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

The forced release function is disabled by default because it greatly


impacts users with low priority levels. This function can be enabled
when required.
If you want high-priority users to access channels first during

Configuration Rule and

assignments, you should enable the forced release function. If the

Adjustment Suggestion

forced release function will be used by AssPreemptstrategy during the


assignment, you should enable this switch.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

[BSC]PreemptionIndAss

Relationship

This parameter is valid only when the BSC-level parameter


PreemptionIndAss is set to "2: According to the cell".

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-167
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.6.6 Preemption allowed when handover (PreemptionInd_1)


Full Name

Preemption allowed when handover

Abbreviation

PreemptionInd_1

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether to allow forced release during handovers. The MSC sends the priority parameters (including priority level,
PCI, and PVI) to the BSC through an assignment command or handover
request message. If this message contains a high priority level and a
valid PCI (indicating this user can preempt the channel of another user),
the BSC can forcibly release the connection to a user whose PVI is
reset (indicating the channel of this user can be preempted by another
user) and then allocate the released resource to this handover request
when no resource is immediately assigned in this handover or the later

Description

handover.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

The forced release function is disabled by default because it greatly


impacts users with low priority levels. This function can be enabled
when required.
If you want high-priority users to access channels first during handovers,

Configuration Rule and


Adjustment Suggestion

you should enable the forced release function. If the forced release
function will be used by HoPreemptstrategy during the handover, you
should enable this switch.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

[BSC]PreemptionIndHo

Relationship

This parameter is valid only when the BSC-level parameter


PreemptionIndHo is set to "2: According to the cell".

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes

4-168
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.7 When assigned forced handover (ForcedHoInd_0)


Full Name

When assigned forced handover

Abbreviation

ForcedHoInd_0

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether to allow forced handover during assignments. The MSC sends the priority parameters (including priority level,
PCI, and PVI) to the BSC through an assignment command message. If
this message contains a high priority level and a valid PCI (indicating this
user can preempt the channel of another user), the BSC can hand over
a user whose PVI is reset (indicating the channel of this user can be preempted by another user) to another cell and then allocate the released
channel on this assignment request when no resource is immediately as-

Description

signed to the higher-priority user.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


If you want high-priority users to access channels through forced

Configuration Rule and

handover during assignments, you should enable this switch. If the

Adjustment Suggestion

forced handover function will be used by AssPreemptstrategy during the


assignment, you should enable this switch.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

[BSC]ForcedHolndAss

4-169
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

This parameter is valid only when the BSC-level parameter


ForcedHolndAss is set to "2: According to the cell".

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.8 Forced handover allowed when handover (ForcedHoInd_1)


Full Name

Forced handover allowed when handover

Abbreviation

ForcedHoInd_1

3GPP Name

Internal

3GPP Reference

None
This parameter determines whether to allow forced handover during handovers. The MSC sends the priority parameters (including priority level,
PCI, and PVI) to the BSC through an assignment command or handover
request message. If this message contains a high priority level and a
valid PCI (indicating this user can preempt the channel of another user),
the BSC can hand over a user whose PVI is reset (indicating the channel
of this user can be preempted by another user) to another cell and then
allocate the released resource to this handover request when no resource

Description

is immediately assigned in this handover or the later handover.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

4-170
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

If you want high-priority users to access channels through forced


Configuration Rule and

handover during assignments, you should enable this switch. If the

Adjustment Suggestion

forced handover function will be used by HoPreemptstrategy during the


handover, you should enable this switch.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

[BSC]ForcedHolndHo
This parameter is valid only when the BSC-level parameter

Relationship

ForcedHolndHo is set to "2: According to the cell".

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.9 Number of candidate cells for handover (CandidateNum)


Full Name

Number of candidate cells for handover

Abbreviation

CandidateNum

3GPP Name

None

3GPP Reference

None
This parameter decides maximum number of candidate cells for handover
that can be contained in "BSSAP HANDOVER REQUIRED" message from

Description

BSC to MSC.

Managed Object

Cell

Value Range and Step

1 ~ 16

Unit

None

Default Value

Default Value
Configuration Reason

None
4-171

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.10 Fast average indication (FastAvg)


Full Name

Fast average indication

Abbreviation

FastAvg

3GPP Name

Internal

3GPP Reference

None
During a call, the system may fail to perform the power control due to little
measurement data because the average calculation can only be started
when the amount of measurement data reaches a certain threshold.
For example, if the threshold for average calculation is 8, the system will
not calculate the average when the BSC only receives five measured
values. However, the BSC can calculate the average of the five
measured values by using the fast averaging function. Once some
measured values are already used for power control, they become
useless and cannot be used for power control any longer because using
old measured values may cause control errors. Therefore, the old

Description

measured values must be discarded.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

4-172
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Unit

None

Default Value

No

Default Value
Configuration Reason

This function can be disabled for V3 base stations.

Configuration Rule and

It is recommended to enable the fast averaging function for SDR base

Adjustment Suggestion

stations to speed up the start of power control.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.11 BCCH switch allowed (CanBcchExch)


Full Name

BCCH switch allowed

Abbreviation

CanBcchExch

3GPP Name

None

3GPP Reference

None

Description

This parameter decides whether the cell allows BCCH switch.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.


4-173

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Turn on this switch when the BCCH switchover function needs to be


Configuration Rule and

enabled. After the BCCH switchover function is enabled, BCCH carrier

Adjustment Suggestion

frequency switchover will be triggered if BCCH carrier frequency comes


across faults, to avoid the service quit of cell.

Change Mode

Offline

Related features

ZGO-03-04-001 Automatic BCCH Recovery

Related Parameters

[BSC]CanBCCHEx

Relationship

The cell switchover takes effect only when BSC switch and the cell level
switch should be turned on at a same time.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.12 SDCCH dynamic configuration allowed (CanSdcchDyn)


Full Name

SDCCH dynamic configuration allowed

Abbreviation

CanSdcchDyn

3GPP Name

None

3GPP Reference

None
This parameter decides whether the cell allows SDCCH dynamic config-

Description

uration.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.

4-174
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Turn on this switch when the SDCCH switchover function needs to be


Configuration Rule and

enabled. After the cell dynamic SDCCH switchover has been enabled,

Adjustment Suggestion

dynamic SDCCH channel handover will be triggered during cell location


update to lower SDCCH channel congestion rate.

Change Mode

Offline

Related features

ZGB-03-02-003 Dynamic Configuration of SDCCH

Related Parameters

[BSC]CanSDCCHDyn

Relationship

The cell switchover takes effect only when BSC switch and the cell level
switch should be turned on at a same time.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.13 Minimal resource threshold (ResourceThs)


Full Name

Minimal resource threshold

Abbreviation

ResourceThs

3GPP Name

None

3GPP Reference

None
This parameter indicates the minimal resource threshold allowed by the

Description

cell. It is used to calculate dynamic cell priority.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

Default Value

20

Default Value

Generally, if no special requirement, the default value should not be

Configuration Reason

modified after it is configured.


4-175

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The lower limit of resources should be larger than 10 due to the


Configuration Rule and

designation limitations of logarithm table. It is recommended not to

Adjustment Suggestion

modify this parameter value.If the threshold is adjusted, the dynamic


priority changes linearly, which is relatively complicated to compute.

Change Mode

Offline

Related features

ZGO-02-02-002 Dynamic Handover Priority Algorithm

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Additional parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.14 Base-band hopping TRX exchange support (Info_0_3)


Full Name

Base-band hopping TRX exchange support

Abbreviation

Info_0_3

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the base band hopping switch-over is
supported. This function is supported only when the BSC and Cell level
switches are all turned on. When a carrier frequency of the base band
hopping group is in fault, the system will automatically move and keep

Description

the faulty frequency out of the group until it resumes.

Managed Object

Cell
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

0: No

4-176
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value
Configuration Reason

This parameter is a switch for a function. It is turned off by default.

Configuration Rule and

The cell that is configured with base band hopping should enable this

Adjustment Suggestion

function to avoid the impact caused by the faulty carrier frequency.

Change Mode

Offline

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

[BSC]Info_0_1

Relationship

A cell supports the base band frequency hopping switch-over only when
the switches in BSC level and cell level parameters are set "Yes".

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.15 Support NCell of channel release (NCELLINDOFCHLREL)


Full Name

Support NCell of channel release

Abbreviation

NCELLINDOFCHLREL

3GPP Name

Cell selection indicator after release of all TCH and SDCCH

3GPP Reference

44.018
When a dual-mode 3G (TD/GSM or WCDMA/GSM) terminal ends a call
in a GSM network, the terminal should be reselected to the 3G network as
soon as possible. According to "Cell selection indicator after release of all
TCH and SDCCH" in the Channel Release message in the 3GPP protocol,
a message can carry the information of GSM adjacent cell, 3G adjacent
cell, and E-Utran adjacent cell. This parameter determines whether a
release message carries the information of 3G adjacent cell. The value 1
indicates that a release message carries the information of 3G adjacent

Description

cell.

Managed Object

Cell
4-177

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0Channel Relaese without Neighbour Cell


1Channel Relaese with UTRAN Neighbour Cell
Value Range and Step

2Channel Relaese with E-UTRAN Neighbour Cell

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and

Enable or disable this function according to the requirements of the

Adjustment Suggestion

local operator.

Change Mode

Offline

Related features

ZGO-02-03-007 Fast Return from GSM to TD-SCDMA

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Additional parameters
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

None

4.6.16 RelEUtranStrategy (RelEUtranStrategy)


Full Name

RelEUtranStrategy

Abbreviation

RelEUtranStrategy

3GPP Name

None

3GPP Reference

None

Description

Strategy for E-Utran Neighbour Select When Release

Managed Object

CELL
0: According to Measurement
1: According to Config

Value Range and Step

2: Prefer Measurement

4-178
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Unit

None

Default Value

Default Value
Configuration Reason

The cell configuration uses common MR.

Configuration Rule and


Adjustment Suggestion

Set this parameter by the MR type.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site config->Site ID->Cell ID->Service Process

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


Additional Params
Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

4.6.17 RelEUtranPrio (RelEUtranPrio)


Full Name

RelEUtranPrio

Abbreviation

RelEUtranPrio

3GPP Name

None

3GPP Reference

None

Description

E-Utran FDD and TDD Prio When Release

Managed Object

CELL
0: Prefer E-Utran TDD Neighbour Cell
1: Prefer E-Utran FDD Neighbour Cell
2: Only E-Utran TDD Neighbour Cell

Value Range and Step

23: Only E-Utran FDD Neighbour Cell

Unit

None

4-179
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value
Configuration Reason

The E-Utran TDD neighbor cell has the highest priority.

Configuration Rule and


Adjustment Suggestion

Set this parameter as needed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set

OMC Access Path

ID->BSC Function ID->Site config->Site ID->Cell ID->Service Process


Additional Params

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

4.6.18 Allowed FACCH call setup after emergency call


(FacchCallInd_0)
Full Name

Allowed FACCH call setup after emergency call

Abbreviation

FacchCallInd_0

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow FACCH call establishment
for call reestablishment. If the FACCH call establishment is allowed, the
BSC can assign TCH according to the actual situation no matter whether
SDCCH is available in the cell when an MS attempts to access the net-

Description

work.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None
4-180

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


Enabling this switch can shorten the delay of call completion. However,

Configuration Rule and


Adjustment Suggestion

using TCH as signalling channel will cause the waste of radio resources.
It is only recommended to enable this function in scenarios having
requirements on the preference and completion delay of emergency
calls.

Change Mode

Offline
ZGB-03-01-004 Immediate TCH Assignment

Related features

ZGB-01-03-001 Emergency Call Handling

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.19 Allowed FACCH call setup when page respond


(FacchCallInd_1)
Full Name

Allowed FACCH call setup when page respond

Abbreviation

FacchCallInd_1

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow call establishment on FACCH
for call origination. If FACCH call establishment is allowed, the BSC can
assign TCH according to the actual situation when an MS attempts to

Description

access the network but no SDCCH is available in the cell.

4-181
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


Enabling this switch can shorten the delay of call completion. However,
using TCH as signalling channel will cause the waste of radio resources.
It is recommended to disable this switch unless specially required.

Change Mode

Offline

Related features

ZGB-03-01-004 Immediate TCH Assignment

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.20 Allowed call setup on FACCH (FacchCallInd_2)


Full Name

Allowed call setup on FACCH

Abbreviation

FacchCallInd_2

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow call establishment on FACCH
for call origination. If FACCH call establishment is allowed, the BSC can
assign TCH according to the actual situation when an MS attempts to

Description

access the network but no SDCCH is available in the cell.

Managed Object

Cell
4-182

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


Enabling this switch can shorten the delay of call completion. However,
using TCH as signalling channel will cause the waste of radio resources.
It is recommended to disable this switch unless specially required.

Change Mode

Offline

Related features

ZGB-03-01-004 Immediate TCH Assignment

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.6.21 Allowed call reestablished on FACCH (FacchCallInd_3)


Full Name

Allowed call reestablished on FACCH

Abbreviation

FacchCallInd_3

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow FACCH call establishment
for call reestablishment. If the FACCH call establishment is allowed, the
BSC can assign TCH according to the actual situation no matter whether
SDCCH is available in the cell when an MS attempts to access the net-

Description

work.

Managed Object

Cell
4-183

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


Enabling this switch can shorten the delay of call completion. However,
using TCH as signalling channel will cause the waste of radio resources.
It is recommended to disable this switch unless specially required.

Change Mode

Offline

Related features

ZGB-03-01-004 Immediate TCH Assignment

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Service Process


Additional parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.7 System Parameters


4.7.1 Interference average period (InterfAvgPrd)
Full Name

Interference average period

Abbreviation

InterfAvgPrd

3GPP Name

INTAVE

3GPP Reference

3GPP TS45.008

4-184
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

The BTS measures the interference on unallocated traffic channels, averages the latest measured interference at a specified period, and converts
the average interference into an interference band. Then it sends the
interference band to the BSC through an RF RESOURCE INDICATION
message. The BSC will take the interference band into consideration beDescription

fore the channel allocation.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

480 ms

Default Value

31

Default Value

Generally, a long period can be set because the fluctuation of uplink

Configuration Reason

interference is not great.


If the parameter value is too small, radio resource information will be

Configuration Rule and


Adjustment Suggestion

frequently reported, which increases the load of the BSC.


If the parameter value is too large, the change of radio resources cannot
be reflected in time due to the long update period of radio resource
report.

Change Mode

Offline

Related features

ZGO-03-02-001 Idle Channel Measurement

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.7.2 Interference Band Boundary (InterfBoundary_0)


Full Name

Interference Band Boundary


4-185

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

InterfBoundary_0

3GPP Name

0
3GPP TS45.008

3GPP Reference

3GPP TS48.008
The BTS measures the interference on unallocated traffic channels,
averages the latest measured interference at a specified period, and
converts the average interference into an interference band. Then it
sends the interference band to the BSC through an RF RESOURCE
INDICATION message. The BSC will take the interference band into
consideration before the channel allocation.
The interface boundaries are used to help the conversion of the
interference level (average) value into corresponding interference band
information. Altogether six boundaries determine five interference
bands. In fact, it is unnecessary to set interference boundary 0 and
interference boundary 5. Interference boundary 0 indicates positive
infinity and interference boundary 5 indicates negative infinity. This
parameter specifies the other four boundaries.
Generally, interference boundary 1 to 4 are within the range from -85

Description

dBm to -115 dBm.

Managed Object

Cell
0..63
0: -110 dBm;
1: -109 dBm
......
63: -47 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The minimum value is set for boundary 0.


If two boundaries are too close, the conversion of interference band will

Configuration Rule and

be too sensitive on the change of interference level. If the difference

Adjustment Suggestion

between two boundaries is too great, the change of interference level


cannot be reflected in time.

Change Mode

Offline

Related features

ZGO-03-02-001 Idle Channel Measurement

Related Parameters

None

Relationship

None

Related Interfaces

None

4-186
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.7.3 Interference Band Boundary (InterfBoundary_1)


Full Name

Interference Band Boundary

Abbreviation

InterfBoundary_1

3GPP Name

X1
3GPP TS45.008

3GPP Reference

3GPP TS48.008
The BTS measures the interference on unallocated traffic channels,
averages the latest measured interference at a specified period, and
converts the average interference into an interference band. Then it
sends the interference band to the BSC through an RF RESOURCE
INDICATION message. The BSC will take the interference band into
consideration before the channel allocation.
The interface boundaries are used to help the conversion of the
interference level (average) value into corresponding interference band
information. Altogether six boundaries determine five interference
bands. In fact, it is unnecessary to set interference boundary 0 and
interference boundary 5. Interference boundary 0 indicates positive
infinity and interference boundary 5 indicates negative infinity. This
parameter specifies the other four boundaries.
Generally, interference boundary 1 to 4 are within the range from -85

Description

dBm to -115 dBm.

Managed Object

Cell

4-187
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0..63
0: -110 dBm
1: -109 dBm
......
63: -47 dBm
Value Range and Step

Step: 1

Unit

None

Default Value

10

Default Value

Set the boundaries of each interference band according to the

Configuration Reason

interference range generally measured in the actual network.


If two boundaries are too close, the conversion of interference band will

Configuration Rule and

be too sensitive on the change of interference level. If the difference

Adjustment Suggestion

between two boundaries is too great, the change of interference level


cannot be reflected in time.

Change Mode

Offline

Related features

ZGO-03-02-001 Idle Channel Measurement

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.7.4 Interference Band Boundary (InterfBoundary_2)


Full Name

Interference Band Boundary

Abbreviation

InterfBoundary_2

3GPP Name

X2
3GPP TS45.008

3GPP Reference

3GPP TS48.008
4-188

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

The BTS measures the interference on unallocated traffic channels,


averages the latest measured interference at a specified period, and
converts the average interference into an interference band. Then it
sends the interference band to the BSC through an RF RESOURCE
INDICATION message. The BSC will take the interference band into
consideration before the channel allocation.
The interface boundaries are used to help the conversion of the
interference level (average) value into corresponding interference band
information. Altogether six boundaries determine five interference
bands. In fact, it is unnecessary to set interference boundary 0 and
interference boundary 5. Interference boundary 0 indicates positive
infinity and interference boundary 5 indicates negative infinity. This
parameter specifies the other four boundaries.
Generally, interference boundary 1 to 4 are within the range from -85
Description

dBm to -115 dBm.

Managed Object

Cell
0..63
0: -110 dBm;
1: -109 dBm
......
63: -47 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

15

Default Value

Set the boundaries of each interference band according to the

Configuration Reason

interference range generally measured in the actual network.


If two boundaries are too close, the conversion of interference band will

Configuration Rule and

be too sensitive on the change of interference level. If the difference

Adjustment Suggestion

between two boundaries is too great, the change of interference level


cannot be reflected in time.

Change Mode

Offline

Related features

ZGO-03-02-001 Idle Channel Measurement

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-189
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.7.5 Interference Band Boundary (InterfBoundary_3)


Full Name

Interference Band Boundary

Abbreviation

InterfBoundary_3

3GPP Name

X3
3GPP TS45.008

3GPP Reference

3GPP TS48.008
The BTS measures the interference on unallocated traffic channels,
averages the latest measured interference at a specified period, and
converts the average interference into an interference band. Then it
sends the interference band to the BSC through an RF RESOURCE
INDICATION message. The BSC will take the interference band into
consideration before the channel allocation.
The interface boundaries are used to help the conversion of the
interference level (average) value into corresponding interference band
information. Altogether six boundaries determine five interference
bands. In fact, it is unnecessary to set interference boundary 0 and
interference boundary 5. Interference boundary 0 indicates positive
infinity and interference boundary 5 indicates negative infinity. This
parameter specifies the other four boundaries.
Generally, interference boundary 1 to 4 are within the range from -85

Description

dBm to -115 dBm.

Managed Object

Cell
0..63
0: -110 dBm;
1: -109 dBm
......
63: -47 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

20

4-190
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value

Set the boundaries of each interference band according to the

Configuration Reason

interference range generally measured in the actual network.


If two boundaries are too close, the conversion of interference band will

Configuration Rule and


Adjustment Suggestion

be too sensitive on the change of interference level. If the difference


between two boundaries is too great, the change of interference level
cannot be reflected in time.

Change Mode

Offline

Related features

ZGO-03-02-001 Idle Channel Measurement

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.7.6 Interference Band Boundary (InterfBoundary_4)


Full Name

Interference Band Boundary

Abbreviation

InterfBoundary_4

3GPP Name

X4
3GPP TS45.008

3GPP Reference

3GPP TS48.008

4-191
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The BTS measures the interference on unallocated traffic channels,


averages the latest measured interference at a specified period, and
converts the average interference into an interference band. Then it
sends the interference band to the BSC through an RF RESOURCE
INDICATION message. The BSC will take the interference band into
consideration before the channel allocation.
The interface boundaries are used to help the conversion of the
interference level (average) value into corresponding interference band
information. Altogether six boundaries determine five interference
bands. In fact, it is unnecessary to set interference boundary 0 and
interference boundary 5. Interference boundary 0 indicates positive
infinity and interference boundary 5 indicates negative infinity. This
parameter specifies the other four boundaries.
Generally, interference boundary 1 to 4 are within the range from -85
Description

dBm to -115 dBm.

Managed Object

Cell
0..63
0: -110 dBm;
1: -109 dBm
......
63: -47 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

25

Default Value

Set the boundaries of each interference band according to the

Configuration Reason

interference range generally measured in the actual network.


If two boundaries are too close, the conversion of interference band will

Configuration Rule and

be too sensitive on the change of interference level. If the difference

Adjustment Suggestion

between two boundaries is too great, the change of interference level


cannot be reflected in time.

Change Mode

Offline

Related features

ZGO-03-02-001 Idle Channel Measurement

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-192
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.7.7 Interference Band Boundary (InterfBoundary_5)


Full Name

Interference Band Boundary

Abbreviation

InterfBoundary_5

3GPP Name

X5
3GPP TS45.008

3GPP Reference

3GPP TS48.008
The BTS measures the interference on unallocated traffic channels,
averages the latest measured interference at a specified period, and
converts the average interference into an interference band. Then it
sends the interference band to the BSC through an RF RESOURCE
INDICATION message. The BSC will take the interference band into
consideration before the channel allocation.
The interface boundaries are used to help the conversion of the
interference level (average) value into corresponding interference band
information. Altogether six boundaries determine five interference
bands. In fact, it is unnecessary to set interference boundary 0 and
interference boundary 5. Interference boundary 0 indicates positive
infinity and interference boundary 5 indicates negative infinity. This
parameter specifies the other four boundaries.
Generally, interference boundary 1 to 4 are within the range from -85

Description

dBm to -115 dBm.

Managed Object

Cell
0..63
0: -110 dBm;
1: -109 dBm
......
63: -47 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

63

4-193
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

The maximum value is set for boundary 5.


If two boundaries are too close, the conversion of interference band will

Configuration Rule and

be too sensitive on the change of interference level. If the difference

Adjustment Suggestion

between two boundaries is too great, the change of interference level


cannot be reflected in time.

Change Mode

Offline

Related features

ZGO-03-02-001 Idle Channel Measurement

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.7.8 MAX value of MS Radio link timeout (MsRadioLKTmOut)


Full Name

MAX value of MS Radio link timeout

Abbreviation

MsRadioLKTmOut

3GPP Name

RADIO_LINK_TIMEOUT

3GPP Reference

3GPP TS45.008 V5.22.0


This parameter indicates the maximum value for the radio link counter S
at the MS side. It is transmitted by BSS on BCCH or SACCH.
The radio performance counter S is used to check the radio link fault.
When MS fails to decode SACCH message(BFI=1), S is decreased by
1. When MS decodes an SACCH message (BFI=0), S is increased by
2. If S is decreased to 0, the radio link has fault. The call needs to be

Description

reestablished or released.

Managed Object

Cell

Value Range and Step

4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, 64
4-194

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Unit

SACCH multi-frame

Default Value

64

Default Value
Configuration Reason

Increase the MS radio link endurance to error codes.


The parameter is correlated with the call drop rate. The call drop rate will

Configuration Rule and


Adjustment Suggestion

be lowered if the parameter is set higher. To improve the call drop rate
index, this parameter can be set higher, But is it not good for the user
perception and system resources utility rate.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.7.9 Radio link failure criterion (ConFailCriterion)


Full Name

Radio link failure criterion

Abbreviation

ConFailCriterion

3GPP Name

Connection Failure Criterion

3GPP Reference

3GPP TS 12.12 V8.0.0

4-195
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The network side (BTS) can judge whether the radio link fails according
to two criteria: one is based on the uplink SACCH error rate and the
other is based on measured value of RXLEV/RXQUAL. This parameter
determines the criteria that BTS adopts to judge whether the connection
is successful or not.
If SACCH error rate is used as the criteria to judge connection failure,
BTS uses the same value of RadioLkTimeout and the same process as
MS does. Thus, BTS avoids inconsistent judgment criteria in the uplink
and downlink directions. Meanwhile, the receiving level threshold and
receiving quality threshold parameters are invalid.
If the measured value of RXLEV/RXQUAL is used as the criteria to
judge connection failure, BTS will use the two parameters: RxLevThs
and RxQualThs.
The value range is as follows:
1: "Uplink SACCH Error Rate Based" (to ensure the same judgment
criteria in the uplink and downlink directions);
Description

2: "RXLEV/RXQUAL Measurement Based"

Managed Object

Cell
1..2

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The judging criteria for MS is adopted here.

Configuration Rule and


Adjustment Suggestion

It is recommended to use the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

4-196
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.7.10 MAX value of BSS Radio link timeout (BsRadioLKTmOut)


Full Name

MAX value of BSS Radio link timeout

Abbreviation

BsRadioLKTmOut

3GPP Name

RADIO_LINK_TIMEOUT

3GPP Reference

3GPP TS45.008 V5.22.0


This parameter is the maximum value for radio link counter S at the BSS

Description

side. It is used in the same way with MsRadioLKTmOut.

Managed Object

Cell

Value Range and Step

4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, 64

Unit

SACCH multi-frame

Default Value

64

Default Value
Configuration Reason

Increase the MS radio link endurance to error codes.


The parameter is correlated with the call drop rate. The call drop rate

Configuration Rule and


Adjustment Suggestion

will be lowered if the parameter is set higher. To improve the call drop
rate index, this parameter can be set higher, But it is not good for the
user perception.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

None
4-197

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

4.7.11 Receiving level threshold (RxLevThs)


Full Name

Receiving level threshold

Abbreviation

RxLevThs

3GPP Name

RXLEV

3GPP Reference

3GPP TS 12.12 V8.0.0


The network side (BTS) can judge whether the radio link fails according
to two criteria: one is "Uplink SACCH Error Rate Based" and the other is
"RXLEV/RXQUAL Measurement Based".
If "RXLEV/RXQUAL Measurement Based" method is adopted as the
criteria to determine the connection failure (The ConFailCriterion is
2), the radio link is considered to be failed when BTS detects that the
uplink receiving level is lower than a threshold, or the uplink receiving
quality is better than a threshold. Receiving level threshold specifies the
threshold value of receiving level.
This parameter is invalid if "Uplink SACCH Error Rate Based" is used
as the criteria to determine connection failure (ConFailCriterion is 1).

Description

Receiving level threshold is one of the configuration parameters of BTS.

Managed Object

Cell
0..63
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
...
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

10

Default Value
Configuration Reason

This parameter gets the experience value.

Configuration Rule and

This parameter indicates the level threshold to determine the radio link

Adjustment Suggestion

fault.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]ConFailCriterion

4-198
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Relationship

This parameter is invalid when ConFailCriterion is set as


"RXLEV/RXQUAL Measurement Based".

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.7.12 Receiving quality threshold (RxQualThs)


Full Name

Receiving quality threshold

Abbreviation

RxQualThs

3GPP Name

RXQUAL

3GPP Reference

3GPP TS 12.12 V8.0.0


The network side (BTS) can determine the radio link failure according to
two kinds of criteria: one is "Uplink SACCH Error Rate Based" and the
other is "RXLEV/RXQUAL Measurement Based".
If "RXLEV/RXQUAL Measurement Based" is adopted as the criterion
to determine the connection failure, the radio link is considered to be
failed when BTS detects that the uplink receiving level is lower than
a threshold, or the uplink receiving quality is better than a threshold.
Receiving quality threshold specifies the threshold value for the receiving
quality.
This parameter is invalid if "Uplink SACCH Error Rate Based" is used as
the criteria to determine a connection failure. This parameter is one of

Description

the configuration parameters of BTS.

Managed Object

Cell

4-199
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0..7
0: corresponding BER range <0.2%;
1: 0.2% .. 0.4%;
2: 0.4% .. 0.8%;
...
6: 6.4% .. 12.8%;
Value Range and Step

7: > 12.8%

Unit

None

Default Value

Default Value
Configuration Reason

This parameter gets the experience value.

Configuration Rule and

This parameter indicates the level threshold to determine the radio link

Adjustment Suggestion

fault.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]ConFailCriterion

Relationship

This parameter is invalid when ConFailCriterion is set as


"RXLEV/RXQUAL Measurement Based".

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.7.13 Radio link failure checking period (RxLevQualprd)


Full Name

Radio link failure checking period

Abbreviation

RxLevQualprd

3GPP Name

None

3GPP Reference

3GPP TS 12.12 V8.0.0

4-200
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter indicates the period to detect radio link failure at the network side (in the unit of SACCH multiframe), including the detection of
channel strength (dBm) and signal quality received by each channel. This
parameter is invalid if "Uplink SACCH Error Rate Based" is used as the
Description

criteria to judge a connection failure.

Managed Object

Cell
1..63

Value Range and Step

Step: 1

Unit

SACCH multi-frame

Default Value

63

Default Value
Configuration Reason

Increase the MS radio link endurance to error codes.


The parameter is correlated with the call drop rate. The call drop rate

Configuration Rule and

will be lowered if the parameter is set higher. To improve the call drop

Adjustment Suggestion

rate index, this parameter can be set higher, But it is not good for the
user perception.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]ConFailCriterion

Relationship

This parameter is invalid when ConFailCriterion is set as


"RXLEV/RXQUAL Measurement Based".

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.7.14 AMR FR (MsRadioLkTmOutAMRFR)


Full Name

AMR FR

Abbreviation

MsRadioLkTmOutAMRFR
4-201

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

RADIO_LINK_TIMEOUT

3GPP Reference

3GPP TS45.008 V5.22.0


This parameter determines the maximum value of the radio link counter
S at the MS side (used for AMR FR). It is transmitted by the BSS on the
BCCH or SACCH channel.
The radio link counter S is used to check radio link faults. When the
MS fails to decode an SACCH message (BFI=1), S is decreased by 1.
When the MS successfully receives an SACCH message (BFI=0), S is
increased by 2. If S is decreased to 0, it indicates that the radio link is

Description

faulty. In this case, the call needs to be reestablished or released.

Managed Object

Cell

Value Range and Step

4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, 64

Unit

SACCH Multi-frame

Default Value

64

Default Value

Increase the endurance of radio links during MS conversation to error

Configuration Reason

codes.
The parameter is directly correlated with the call drop rate. The higher

Configuration Rule and

the value, the lower the call drop rate. To improve the KPI of call drop

Adjustment Suggestion

rate, this parameter can be configured to a large value. However, it has


negative impact on user perception and usage of system resources.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4-202
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.7.15 AMR HR (MsRadioLkTmOutAMRHR)


Full Name

AMR HR

Abbreviation

MsRadioLkTmOutAMRHR

3GPP Name

RADIO_LINK_TIMEOUT

3GPP Reference

3GPP TS45.008 V5.22.0


This parameter determines the maximum value of the radio link counter
S at the MS side (used for AMR HR). It is transmitted by the BSS on the
BCCH or SACCH channel.
The radio link counter S is used to check radio link faults. When the
MS fails to decode an SACCH message (BFI=1), S is decreased by 1.
When the MS successfully receives an SACCH message (BFI=0), S is
increased by 2. If S is decreased to 0, it indicates that the radio link is

Description

faulty. In this case, the call needs to be reestablished or released.

Managed Object

Cell

Value Range and Step

4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, 64

Unit

SACCH Multi-frame

Default Value

64

Default Value

Increase the endurance of radio links during MS conversation to error

Configuration Reason

codes.
The parameter is directly correlated with the call drop rate. The higher

Configuration Rule and

the value, the lower the call drop rate. To improve the KPI of call drop

Adjustment Suggestion

rate, this parameter can be configured to a large value. However, it has


negative impact on user perception and usage of system resources.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


parameters
Parameter Modifying
Version

iBSCV6.20.710

4-203
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

4.7.16 AMR WFS (MsRadioLkOutAMRWFS)


Full Name

AMR WFS

Abbreviation

MsRadioLkOutAMRWFS

3GPP Name

RADIO_LINK_TIMEOUT

3GPP Reference

3GPP TS45.008 V5.22.0


This parameter determines the maximum value of the radio link counter
S at the MS side (used for AMR WFS). It is transmitted by the BSS
on the BCCH or SACCH channel.
The radio link counter S is used to check radio link faults. When the
MS fails to decode an SACCH message (BFI=1), S is decreased by 1.
When the MS successfully receives an SACCH message (BFI=0), S is
increased by 2. If S is decreased to 0, it indicates that the radio link is

Description

faulty. In this case, the call needs to be reestablished or released.

Managed Object

Cell

Value Range and Step

4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, 64

Unit

SACCH Multi-frame

Default Value

64

Default Value

Increase the endurance of radio links during MS conversation to error

Configuration Reason

codes.
The parameter is directly correlated with the call drop rate. The higher

Configuration Rule and

the value, the lower the call drop rate. To improve the KPI of call drop

Adjustment Suggestion

rate, this parameter can be configured to a large value. However, it has


negative impact on user perception and usage of system resources.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

No

4-204
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.7.17 AMR-WB OWFS (MsRadioLkOutAMROWFS)


Full Name

AMR-WB OWFS

Abbreviation

MsRadioLkOutAMROWFS

3GPP Name

RADIO_LINK_TIMEOUT

3GPP Reference

3GPP TS45.008 V5.22.0


This parameter determines the maximum value of the radio link counter
S at the MS side (used for AMR-WB OWFS). It is transmitted by the BSS
on the BCCH or SACCH channel.
The radio link counter S is used to check radio link faults. When the
MS fails to decode an SACCH message (BFI=1), S is decreased by 1.
When the MS successfully receives an SACCH message (BFI=0), S is
increased by 2. If S is decreased to 0, it indicates that the radio link is

Description

faulty. In this case, the call needs to be reestablished or released.

Managed Object

Cell

Value Range and Step

4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, 64

Unit

SACCH Multi-frame

Default Value

64

Default Value

Increase the endurance of radio links during MS conversation to error

Configuration Reason

codes.
The parameter is directly correlated with the call drop rate. The higher

Configuration Rule and

the value, the lower the call drop rate. To improve the KPI of call drop

Adjustment Suggestion

rate, this parameter can be configured to a large value. However, it has


negative impact on user perception and usage of system resources.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

4-205
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.7.18 AMR-WB OWHR (MsRadioLkOutAMROWHR)


Full Name

AMR-WB OWHR

Abbreviation

MsRadioLkOutAMROWHR

3GPP Name

RADIO_LINK_TIMEOUT

3GPP Reference

3GPP TS45.008 V5.22.0


This parameter determines the maximum value of the radio link counter
S at the MS side (used for AMR-WB OWHS). It is transmitted by the
BSS on the BCCH or SACCH channel.
The radio link counter S is used to check radio link faults. When the
MS fails to decode an SACCH message (BFI=1), S is decreased by 1.
When the MS successfully receives an SACCH message (BFI=0), S is
increased by 2. If S is decreased to 0, it indicates that the radio link is

Description

faulty. In this case, the call needs to be reestablished or released.

Managed Object

Cell

Value Range and Step

4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48, 52, 56, 60, 64

Unit

SACCH Multi-frame

Default Value

64

Default Value

Increase the endurance of radio links during MS conversation to error

Configuration Reason

codes.
The parameter is directly correlated with the call drop rate. The higher

Configuration Rule and

the value, the lower the call drop rate. To improve the KPI of call drop

Adjustment Suggestion

rate, this parameter can be configured to a large value. However, it has


negative impact on user perception and usage of system resources.

Change Mode

Offline

Related features

None

4-206
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->System


parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.8 AMR Half Method Parameters


4.8.1 AMR Half Active Codec Set (AmrHalfAcs)
Full Name

AMR Half Active Codec Set

Abbreviation

AmrHalfAcs

3GPP Name

AMR Active Codec Set

3GPP Reference

45.009
The code has eight bits. Bits 6 to 8 are reserved. 7.40 kbit/s is bit 5,
6.70 kbit/s bit 4, 5.9 kbit/s is bit 3, 5.15 kbit/s is bit 2, and 4.75 kbit/s
bit 1. Yes stands for 1, that is, including this speech coding mode. No
stands for 0, that is, excluding this speech coding mode. At most four
coding modes can be set.
When interface A is in IP mode, ACS is decided by the MSC and this

Description

parameter is invalid.

Managed Object

CEll
The value is Yes or No for 4.75 kbit/s, 5.15 kbit/s, 5.90 kbit/s, 6.70 kbit/s,

Value Range and Step

and 7.40 kbit/s.

Unit

None
The default value is "Yes, No, Yes, No, Yes", that is, 00010101. In this
case, you can export the decimal number "21" from the network planning

Default Value

and optimization table.

4-207
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

Under TrFO configuration, 5.15k is unavailable to the rate set supported


by CN. This default value is configured so as to not affect the success
rate of TFO establishment when AMR+TFO is configured.
Generally, high rates are used along with low rates. When a cell has
good radio signal quality, you can select high rates only. Otherwise, you
can select low rates only.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[Cell]AmrStartMode
When only one of the five bits of this parameter is set to No, the value
range is 1 to 4.
When two of the five bits of this parameter are set to No, the value
range is 1 to 3.

Relationship

When three of the five bits of this parameter are set to No, the value
range is 1 to 2.
When four of the five bits of this parameter are set to No, the value
range is 1.
When the five bits of this parameter are all set to No, the value range is
null.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR Half


Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.8.2 Thresholds of AMR (AmrThresholds)


Full Name

Thresholds of AMR

Abbreviation

AmrThresholds

3GPP Name

threshold

3GPP Reference

45.009

4-208
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

The parameter AmrThresholds includes five elements: AmrThresholds1,


AmrThresholds2, AmrThresholds3, AmrThresholds4, and
AmrThresholds5, which meet the following requirements:
AmrThresholds1 AmrThresholds2 AmrThresholds3
AmrThresholds4 AmrThresholds5
AmrThresholds1 + AmrHysteresis1 AmrThresholds2 +
AmrHysteresis2AmrThresholds3 + AmrHysteresis3 AmrThresholds4
+ AmrHysteresis4 AmrThresholds5 + AmrHysteresis5
When CIR is more than AmrThresholdsN+AmrHysteresisN, the speech
coding rate will be changed to mode N+1. When CIR is less than
Description

AmrThresholdsN, the speech coding rate will be changed to mode N.

Managed Object

Cell
The value rage is 0 to 63 in modes 1, 2, 3, 4, and 5.
0: 0.0 dB
1: 0.5 dB
2: 1.0 dB
...

Value Range and Step

63: 31.5 dB

Unit

0.5 dB

Default Value

[18, 20, 23, 26, 30]

Default Value
Configuration Reason

The default value is set to improve the performance of AMR function.

Configuration Rule and

Generally, you do not have to adjust the setting of this parameter unless

Adjustment Suggestion

the FER measured by the BTS exceeds 1%.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[Cell]AmrHysteresis
AmrThresholds1 AmrThresholds2 AmrThresholds3
AmrThresholds4 AmrThresholds5

Relationship

AmrThresholds1 + AmrHysteresis1 AmrThresholds2 +


AmrHysteresis2AmrThresholds3 + AmrHysteresis3 AmrThresholds4
+ AmrHysteresis4 AmrThresholds5 + AmrHysteresis5

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR Half


Method Paras
4-209

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.8.3 Hysteresis of AMR (AmrHysteresis)


Full Name

Hysteresis of AMR

Abbreviation

AmrHysteresis

3GPP Name

hysteresis

3GPP Reference

45.009
The parameter AmrThresholds includes five elements: AmrThresholds1,
AmrThresholds2, AmrThresholds3, AmrThresholds4, and
AmrThresholds5, which meet the following requirements:
AmrThresholds1 AmrThresholds2 AmrThresholds3
AmrThresholds4 AmrThresholds5
AmrThresholds1 + AmrHysteresis1 AmrThresholds2 +
AmrHysteresis2AmrThresholds3 + AmrHysteresis3 AmrThresholds4
+ AmrHysteresis4 AmrThresholds5 + AmrHysteresis5
When CIR is more than AmrThresholdsN+AmrHysteresisN, the speech
coding rate will be changed to mode N+1. When CIR is less than

Description

AmrThresholdsN, the speech coding rate will be changed to mode N.

Managed Object

Cell
The value rage is 0 to 15 in modes 1, 2, 3, 4, and 5.
0: 0.0 dB
1: 0.5 dB
2: 1.0 dB
...

Value Range and Step

15: 7.5 dB

Unit

0.5 dB

Default Value

[3, 3, 3, 4, 4]

Default Value
Configuration Reason

The default value is set to improve the performance of AMR function.


By checking the frequency of rate adjustments (through tests, analyses,

Configuration Rule and

or AMR rate monitoring tools), you can decide whether this parameter

Adjustment Suggestion

is set properly. When the rate is adjusted too frequently, you can set
the parameter to a higher value.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)


4-210

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

[Cell]AmrThresholds
AmrThresholds1 + AmrHysteresis1 AmrThresholds2 + AmrHysteresis2

Relationship

AmrThresholds3 + AmrHysteresis3 AmrThresholds4 +


AmrHysteresis4 AmrThresholds5 + AmrHysteresis5

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR Half


Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.8.4 Initial codec mode (IsAmrlCM)


Full Name

Initial codec mode

Abbreviation

IsAmrlCM

3GPP Name

Initial Codec Mode Indicator

3GPP Reference

45.009
This parameter decides which one, the coding mode specified in
Startmode or the default initial coding mode specified in the protocol
45.009, is used as the initial AMR speech coding mode.
When one mode is used, the corresponding rate is used as the initial
coding mode.
When two or three modes are used, the lowest rate is used as the
initial coding mode.
When four modes are used, the second lowest rate is used as the initial
coding mode.
When interface A is in IP mode, this parameter is not used. The initial
coding mode depends on IpaAMRStartMode in the system control

Description

parameters.

Managed Object

Cell

Value Range and Step

Start-mode codec, Initial codec mode

Unit

None

4-211
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Start-mode codec

Default Value
Configuration Reason

In the default mode, the initial coding mode can be set as needed.
In good radio network conditions, Start-mode codec and high-rate

Configuration Rule and

coding modes are recommended.

Adjustment Suggestion

In poor radio network conditions, you can set this parameter to "Initial
codec mode", that is, the default initial rate specified in the protocol.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[Cell]AmrStartMode

Relationship

AmrStartMode is valid only when IsAmrlCM is set to "Start-mode codec".

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR Half


Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.8.5 Start mode (AmrStartMode)


Full Name

Start mode

Abbreviation

AmrStartMode

3GPP Name

Start Mode

3GPP Reference

44.018

Description

Startmode code mode

Managed Object

Cell

4-212
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

The value range is described as follows:


1: The coding mode with the lowest code rate is selected as the initial
coding mode.
2: If there is more than one coding mode, the coding mode with the
second lowest code rate will be selected.
3: If there are more than two coding modes, the coding mode with the
third lowest code rate will be selected.
4: If there are more than three coding modes, the coding mode with the
Value Range and Step

fourth lowest code rate will be selected.

Unit

None
This parameter is set as the maximum rate in accordance with the number
of the current selected rates. For example, it is set to 4 if the full rate
is configured with 4 coding modes, and the maximum coding mode is

Default Value

selected as the initial rate.


Previously, the minimum coding mode is used in which the MOS value

Default Value
Configuration Reason

increased from the lower value to the stabilized value takes a long period
of time, which is due to the limitation of the current rate adjustment
mechanision of the version. In this case, the initial coding mode is
changed into the maximum coding mode.

Configuration Rule and

In good radio network conditions, high initial rates can be used to

Adjustment Suggestion

improve voice quality.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[Cell]AmrHarfAcs
[Cell]IsAmrlCM
When only one of the five bits of the parameter AmrHarfAcs is set to No,
the value range is 1 to 4.
When two of the five bits of the parameter AmrHarfAcs are set to No,
the value range is 1 to 3.
When three of the five bits of the parameter AmrHarfAcs are set to No,

Relationship

the value range is 1 to 3.


When four of the five bits of the parameter AmrHarfAcs are set to No,
the value range is 1.
When the five bits of the parameter AmrHarfAcs are all set to No, the
value range is null.
AmrStartMode is valid only when IsAmrlCM is set to "Start-mode codec".

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-213
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR Half


Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.8.6 Enable noise control (IsAmrNscb)


Full Name

Enable noise control

Abbreviation

IsAmrNscb

3GPP Name

Noise Suppression Control Bit

3GPP Reference

44.018
This parameter decides whether to disable the AMR noise control
function at the MS side, that is, whether to suppress the background
noise and keep the original voice quality. Noise suppression is a function
at the MS side.
No: Noise suppression enabled.

Description

Yes: Noise suppression disabled.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

Enabling noise suppression can minimize noise and improve voice

Configuration Reason

quality.

Configuration Rule and


Adjustment Suggestion

Generally, it is recommended to enable the noise suppression function.


When voice quality problems occur, you should check the setting of
this parameter.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

None

Relationship

None

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

4-214
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR Half


Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.9 AMR Full Method Parameters


4.9.1 AMR full Active Codec Set (AmrFullAcs)
Full Name

AMR full Active Codec Set

Abbreviation

AmrFullAcs

3GPP Name

AMR Active Codec Set

3GPP Reference

45.009
The code has eight bits. 12.2 kbit/s is bit 8, 10.2 kbit/s bit 7, 7.95 kbit/s
bit 6, 7.40 kbit/s bit 5, 6.70 kbit/s bit 4, 5.9 kbit/s bit 3, 5.15 kbit/s bit 2,
and 4.75 kbit/s bit 1. Yes stands for 1, that is, including this speech
coding mode. No stands for 0, that is, excluding this speech coding
mode. At most four coding modes can be set.
When interface A is in IP mode, ACS is decided by the MSC and this

Description

parameter is invalid.

Managed Object

Cell
The value is Yes or No for 4.75 kbit/s, 5.15 kbit/s, 5.90 kbit/s, 6.70 kbit/s,

Value Range and Step

7.40 kbit/s, 7.95 kbit/s, 10.2 kbit/s, and 12.2 kbit/s.

Unit

None
The default value is "Yes, No, Yes, No, Yes, No, No, Yes", that is,
10010101. In this case, you can export the decimal number "149" from

Default Value
Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion
Change Mode

the network planning and optimization table.


Under TrFO configuration, 5.15k is unavailable to the rate set supported
by CN. This default value is configured so as to not affect the success
rate of TFO establishment when AMR+TFO is configured.
Generally, high rates are used along with low rates. When a cell has
good radio signal quality, you can select high rates only. Otherwise, you
can select low rates only.
Offline
4-215

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[Cell]AmrStartMode
When four of the eight bits of this parameter are set to No, the value
range is 1 to 4.
When five of the eight bits of this parameter are set to No, the value
range is 1 to 3.

Relationship

When six of the eight bits of this parameter are set to No, the value
range is 1 to 2.
When seven of the eight bits of this parameter are set to No, the value
range is 1.
When the eight bits of this parameter are all set to No, the value range is
null.

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR Full

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Method Paras
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.9.2 Thresholds of AMR (AmrThresholds)


Full Name

Thresholds of AMR

Abbreviation

AmrThresholds

3GPP Name

threshold

3GPP Reference

45.009

4-216
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter includes seven elements: AmrThresholds1,


AmrThresholds2, AmrThresholds3, AmrThresholds4, AmrThresholds5,
AmrThresholds6, and AmrThresholds7, which meet the following
requirements:
AmrThresholds1 AmrThresholds2 AmrThresholds3
AmrThresholds4 AmrThresholds5 AmrThresholds6
AmrThresholds7, AmrThresholds1 + AmrHysteresis1 AmrThresholds2
+ AmrHysteresis2 AmrThresholds3 + AmrHysteresis3
AmrThresholds4 + AmrHysteresis4 AmrThresholds5 + AmrHysteresis5
AmrThresholds6 + AmrHysteresis6 AmrThresholds7 +
Description

AmrHysteresis7

Managed Object

Cell
The value rage is 0 to 63 in modes 1, 2, 3, 4, 5, 6 and 7.
0: 0.0 dB
1: 0.5 dB
2: 1.0 dB
...

Value Range and Step

63: 31.5 dB

Unit

0.5 dB

Default Value

[13, 14, 15, 17, 18, 20, 23]

Default Value
Configuration Reason

The default value is set to improve the performance of AMR function.

Configuration Rule and

Generally, you do not have to adjust the setting of this parameter unless

Adjustment Suggestion

the FER measured by the BTS exceeds 1%.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[Cell]AmrHysteresis
This parameter includes seven elements: AmrThresholds1,
AmrThresholds2, AmrThresholds3, AmrThresholds4, AmrThresholds5,
AmrThresholds6, and AmrThresholds7, which meet the following
requirements:
AmrThresholds1 AmrThresholds2 AmrThresholds3

Relationship

AmrThresholds4 AmrThresholds5 AmrThresholds6


AmrThresholds7, AmrThresholds1 + AmrHysteresis1 AmrThresholds2
+ AmrHysteresis2 AmrThresholds3 + AmrHysteresis3
AmrThresholds4 + AmrHysteresis4 AmrThresholds5 + AmrHysteresis5
AmrThresholds6 + AmrHysteresis6 AmrThresholds7 +
AmrHysteresis7

Related Interfaces

Um, Abis

Impact on Equipment

0
4-217

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR Full


Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.9.3 Hysteresis of AMR (AmrHysteresis)


Full Name

Hysteresis of AMR

Abbreviation

AmrHysteresis

3GPP Name

hysteresis

3GPP Reference

45.009
This parameter includes seven elements: AmrHysteresis1,
AmrHysteresis2, AmrHysteresis3, AmrHysteresis4, AmrHysteresis5,
AmrHysteresis6, and AmrHysteresis7, which meet the following
requirements:
AmrThresholds1 + AmrHysteresis1 AmrThresholds2 + AmrHysteresis2
AmrThresholds3 + AmrHysteresis3 AmrThresholds4 +
AmrHysteresis4 AmrThresholds5 + AmrHysteresis5 AmrThresholds6

Description

+ AmrHysteresis6 AmrThresholds7 + AmrHysteresis7

Managed Object

Cell
The value rage is 0 to 15 in modes 1, 2, 3, 4, 5, 6 and 7.
0: 0.0 dB
1: 0.5 dB
2: 1.0 dB
...

Value Range and Step

15: 7.5 dB

Unit

0.5 dB

Default Value

[3, 3, 3, 3, 3, 4, 4]

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is set to improve the performance of AMR function.


By checking the frequency of rate adjustments, you can decide whether
this parameter is set properly. When the rate is adjusted too frequently,
you can set the parameter to a higher value.

4-218
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[Cell]AmrThresholds
This parameter includes seven elements: AmrHysteresis1,
AmrHysteresis2, AmrHysteresis3, AmrHysteresis4, AmrHysteresis5,
AmrHysteresis6, and AmrHysteresis7, which meet the following

Relationship

requirements:
AmrThresholds1 + AmrHysteresis1 AmrThresholds2 + AmrHysteresis2
AmrThresholds3 + AmrHysteresis3 AmrThresholds4 +
AmrHysteresis4 AmrThresholds5 + AmrHysteresis5 AmrThresholds6
+ AmrHysteresis6 AmrThresholds7 + AmrHysteresis7

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR Full

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Method Paras
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.9.4 Initial codec mode (IsAmrICM)


Full Name

Initial codec mode

Abbreviation

IsAmrICM

3GPP Name

Initial Codec Mode Indicator

3GPP Reference

45.009

4-219
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter decides which one, the coding mode specified in


Startmode or the default initial coding mode specified in the protocol
45.009, is used as the initial AMR speech coding mode.
When one mode is used, the corresponding rate is used as the initial
coding mode.
When two or three modes are used, the lowest rate is used as the
initial coding mode.
When four modes are used, the second lowest rate is used as the initial
coding mode.
When interface A is in IP mode, this parameter is not used. The initial
coding mode depends on IpaAMRStartMode in the system control
Description

parameters.

Managed Object

Cell

Value Range and Step

Start-mode codec, Initial codec mode

Unit

None

Default Value

Start-mode codec

Default Value
Configuration Reason

In the default mode, the initial coding mode can be set as needed.

Configuration Rule and

Generally, you can set this parameter to "Initial codec mode", that is, the

Adjustment Suggestion

default initial rate specified in the protocol.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

[Cell]AmrStartMode

Relationship

AmrStartMode is valid only when IsAmrlCM is set to "Start-mode codec".

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR Full


Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-220
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.9.5 Start mode (AmrStartMode)


Full Name

Start mode

Abbreviation

AmrStartMode

3GPP Name

Start Mode

3GPP Reference

44.018

Description

Startmode codec mode

Managed Object

Cell
When four of the eight bits of the parameter AmrFullAcs are set to No,
the value range is 1 to 4.
When five of the eight bits of the parameter AmrFullAcs are set to No,
the value range is 1 to 3.
When six of the eight bits of the parameter AmrFullAcs are set to No,
the value range is 1 to 2.
When seven of the eight bits of the parameter AmrFullAcs are set to
No, the value range is 1.
When the eight bits of the parameter AmrFullAcs are all set to No, the
value range is null.
The value range is described as follows:
1: The coding mode with the lowest code rate is selected as the initial
coding mode.
2: If there is more than one coding mode, the coding mode with the
second lowest code rate will be selected.
3: If there are more than two coding modes, the coding mode with the
third lowest code rate will be selected.
4: If there are more than three coding modes, the coding mode with the

Value Range and Step

fourth lowest code rate will be selected.

Unit

None
This parameter is set as the maximum rate in accordance with the number
of the current selected rates. For example, it is set to 4 if the full rate
is configured with 4 coding modes, and the maximum coding mode is

Default Value

selected as the initial rate.


Previously, the minimum coding mode is used in which the MOS value

Default Value
Configuration Reason

increased from the lower value to the stabilized value takes a long period
of time, which is due to the limitation of the current rate adjustment
mechanision of the version. In this case, the initial coding mode is
changed into the maximum coding mode.

Configuration Rule and

High initial rates can be used in cells that have good radio network

Adjustment Suggestion

conditions.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)


4-221

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

[Cell]AmrHarfAcs
[Cell]IsAmrlCM
When four of the eight bits of this parameter are set to No, the value
range is 1 to 4.
When five of the eight bits of this parameter are set to No, the value
range is 1 to 3.
When six of the eight bits of this parameter are set to No, the value

Relationship

range is 1 to 2.
When seven of the eight bits of this parameter are set to No, the value
range is 1.
When the eight bits of this parameter are all set to No, the value range is
null.
AmrStartMode is valid only when IsAmrlCM is set to "Start-mode codec".

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR Full


Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.9.6 Enable noise control (IsAmrNscb)


Full Name

Enable noise control

Abbreviation

IsAmrNscb

3GPP Name

Noise Suppression Control Bit

3GPP Reference

44.018
This parameter decides whether to disable the AMR noise control
function at the MS side, that is, whether to suppress the background
noise and keep the original voice quality. Noise suppression is a function
at the MS side.
No: Noise suppression enabled.

Description

Yes: Noise suppression disabled.

Managed Object

Cell

4-222
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

Enabling noise suppression can minimize noise and improve voice

Configuration Reason

quality.

Configuration Rule and


Adjustment Suggestion

Generally, it is recommended to enable the noise suppression function.


When voice quality problems occur, you should check the setting of
this parameter.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

None

Relationship

None

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR Full


Method Paras

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10 Other Parameters


4.10.1 Preprocessing indication (Preprocess)
Full Name

Preprocessing indication

Abbreviation

Preprocess

3GPP Name

None

3GPP Reference

None

4-223
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The survey report contains large amount (message amount) of Abis


interface information. Preprocess of the survey report can be transferred
to BTS to reduce the burden of Abis interface link. After the preprocess,
the BTS averages the survey data of MS by its own, and reports to BSC
in a lower frequency.
The average reporting period can be two, three or four SACCH
multi-frames (480 ms). That is, the frequency decreases from the
original twice/s to once/2 s, so the message amount of the Abis interface
decreases. However, the decrease of message amount still depends on
whether the message length before the preprocess is the same as that
after preprocess. One disadvantage of preprocess is that the handover
control and power control are not in time, which increases the possibility
of disconnection rate. This parameter determines whether to use the
preprocess and its period.
The values are as follows:
0: Do not use preprocess
2: preprocess, 2 SACCH block period
3: preprocess, 3 SACCH block period
4: preprocess, 4 SACCH block period
5: preprocess on TCH, 2 SACCH block period
6: preprocess on TCH, 3 SACCH block period
7: preprocess on TCH, 4 SACCH block period
Other values: Reserved
2, 3, and 4 indicate that the BTS preprocesses measurement reports,
and reports the measurement reports about the SDCCH and TCH
channels to the BSC in accordance with the period of 2 to 4 SACCH
multiframes.
5, 6, and 7 indicate that the BTS preprocesses measurement reports,
and reports the measurement reports about the TCH channel to the BSC
Description

in accordance with the period of 2 to 4 SACCH multiframes.

Managed Object

Cell
0 .. 7

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value is set to meet a compromise between the decrease of

Configuration Reason

the Abis message amount and the timeliness of process.

4-224
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

It is suggested to disable all preprocesses.


If the default value is set as small, the handover frequency increases,
Configuration Rule and

which helps improve handover success rate but affects calldrop rate

Adjustment Suggestion

and coverage rate.


If the parameter is set as large, handover lagging increases, which
affects the calldrop rate and coverage rate.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.2 Reserved rate of EMLPP (EMLPPThs)


Full Name

Reserved rate of EMLPP

Abbreviation

EMLPPThs

3GPP Name

None

3GPP Reference

None
When using high priority user to access service, that is, EMLPP service,
the system may configure certain reserved channels for the users with
high priority to access CS service. The reserved channels equal to the
reserved rate of EMLPP multiplying the minimum value of available chan-

Description

nels (including TCH and PD) and idle TCHP channels.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

4-225
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

20

Default Value

This parameter is a cell-level parameter, of which 20% is reserved

Configuration Reason

according to experience.
The higher the parameter value is, the higher the reserved rate is, the

Configuration Rule and


Adjustment Suggestion

users with high priority are ensured, and comparatively fewer channel
resources are distributed to users with low priority.
The lower the parameter value is, the lower the reserved rate is, and the
less guarantee the users with high priority get.

Change Mode

Offline

Related features

ZGO-01-03-001 Emlpp

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.3 Use cell EMLPP Threshold (UseCellEmlppThs)


Full Name

Use cell EMLPP Threshold

Abbreviation

UseCellEmlppThs

3GPP Name

None

3GPP Reference

None
This parameter defines whether to use eMLPPThs. If yes, you shall select

Description

cell property, otherwise to select BSC property.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

4-226
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value
Configuration Reason

The global parameter is used by default.

Configuration Rule and

This switch can be enabled when one cell needs to be configured with

Adjustment Suggestion

the EMLPP parameter independently.

Change Mode

Offline

Related features

ZGO-01-03-001 Emlpp

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.4 Frequency offset correct support (Info_0_1)


Full Name

Frequency offset correct support

Abbreviation

Info_0_1

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the frequency offset correction is supported. This function is applied on the high-speed railway and GSM-R

Description

situations, which can raise the uplink receiving performance.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value

In most cases, frequency offset correction is not needed because most

Configuration Reason

MSs does not move fast.

4-227
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and

In the coverage area of high-speed railway and expressway, this

Adjustment Suggestion

parameter can be set to "Yes".

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.5 Maximum power on handover command support (Info_0_2)


Full Name

Maximum power on handover command support

Abbreviation

Info_0_2

3GPP Name

None

3GPP Reference

None
It indicates whether handover commands are issued in the highest trans-

Description

mission power.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value

There will be some interference if handover commands are issued in

Configuration Reason

the highest transmission power.


Some power interference will be brought up if handover commands are

Configuration Rule and

issued in the highest transmission power. This function can be enabled

Adjustment Suggestion

in the coverage area with weak signals. It can improve the success rate
of handover commands received by MS.

4-228
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Change Mode

Offline

Related features

ZGO-02-02-019 Handover Command Power Boost

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.6 MR Report Time Bmp (MrRptTimeBmp)


Full Name

MR Report Time Bmp

Abbreviation

MrRptTimeBmp

3GPP Name

None

3GPP Reference

None
This parameter provides a check function about 0 .. 23 time points.
Measurement data report can be enabled at different points. Each time
point indicates an hour, within 0 .. 23 hours.
MR data can be reported only when corresponding time points are

Description

selected and the measurement report function is enabled.

Managed Object

Cell
checked, unchecked
Checked: Measurement report function is enabled within this time period;

Value Range and Step

Unchecked: Measurement report is disabled within this time period;

Unit

None

Default Value

Unchecked

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.

Configuration Rule and


Adjustment Suggestion

Set this parameter according to the time needed by MR collection.


4-229

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.7 Non Cipher Mode support (CipherMode_0_0)


Full Name

Non Cipher Mode support

Abbreviation

CipherMode_0_0

3GPP Name

None

3GPP Reference

None
This parameter indicates the cipher mode supported by the cell. When the
MSC receives a BSSAP CIPHER MODE COMMAND, BSSAP ASSIGNMENT REQUEST, or BSSAP HANDOVER COMMAND message, which
specifying the required encryption algorithm, the BSC checks whether the
cell supports the encryption algorithm and gives a response according to

Description

the check result.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The BSS must support the unencrypted mode.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline
4-230

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.8 Cipher Mode support A5/1 (CipherMode_0_1)


Full Name

Cipher Mode support A5/1

Abbreviation

CipherMode_0_1

3GPP Name

None

3GPP Reference

None
This parameter indicates the cipher mode supported by the cell. When the
MSC receives a BSSAP CIPHER MODE COMMAND, BSSAP ASSIGNMENT REQUEST, or BSSAP HANDOVER COMMAND message, which
specifying the required encryption algorithm, the BSC checks whether the
cell supports the encryption algorithm and gives a response according to

Description

the check result.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value

Generally, this functional switch is disabled by default, that is, it is

Configuration Reason

unnecessary to enable the support of this encryption algorithm.

Configuration Rule and

The BSS and the MSC must support the same encryption algorithm.

Adjustment Suggestion

Enable this switch according to the actual situation on site.

Change Mode

Offline

Related features

ZGB-06-02-001 Support of A5/1 and A5/2 Ciphering Algorithm

4-231
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.9 Cipher Mode support A5/2 (CipherMode_0_2)


Full Name

Cipher Mode support A5/2

Abbreviation

CipherMode_0_2

3GPP Name

None

3GPP Reference

None
This parameter indicates the cipher mode supported by the cell. When the
MSC receives a BSSAP CIPHER MODE COMMAND, BSSAP ASSIGNMENT REQUEST, or BSSAP HANDOVER COMMAND message, which
specifying the required encryption algorithm, the BSC checks whether the
cell supports the encryption algorithm and gives a response according to

Description

the check result.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value

Generally, this functional switch is disabled by default, that is, it is

Configuration Reason

unnecessary to enable the support of this encryption algorithm.

Configuration Rule and

The BSS and the MSC must support the same encryption algorithm.

Adjustment Suggestion

Enable this switch according to the actual situation on site.

Change Mode

Offline

Related features

ZGB-06-02-001 Support of A5/1 and A5/2 Ciphering Algorithm

4-232
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.10 Cipher Mode support A5/3 (CipherMode_0_3)


Full Name

Cipher Mode support A5/3

Abbreviation

CipherMode_0_3

3GPP Name

None

3GPP Reference

None
This parameter indicates the cipher mode supported by the cell. When the
MSC receives a BSSAP CIPHER MODE COMMAND, BSSAP ASSIGNMENT REQUEST, or BSSAP HANDOVER COMMAND message, which
specifying the required encryption algorithm, the BSC checks whether the
cell supports the encryption algorithm and gives a response according to

Description

the check result.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value

Generally, this functional switch is disabled by default, that is, it is

Configuration Reason

unnecessary to enable the support of this encryption algorithm.


The BSS and the MSC must support the same encryption algorithm.

Configuration Rule and

Enable this switch according to the actual situation on site.

Adjustment Suggestion

The BSC can distinguish the version of the BTS and find whether the
BTS supports the cipher mode A5/3.

Change Mode

Offline

4-233
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGO-06-02-001 A5/3 Ciphering Algorithm

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.11 Cipher Mode support A5/4 (CipherMode_0_4)


Full Name

Cipher Mode support A5/4

Abbreviation

CipherMode_0_4

3GPP Name

None

3GPP Reference

None
This parameter indicates the cipher mode supported by the cell. When the
MSC receives a BSSAP CIPHER MODE COMMAND, BSSAP ASSIGNMENT REQUEST, or BSSAP HANDOVER COMMAND message, which
specifying the required encryption algorithm, the BSC checks whether the
cell supports the encryption algorithm and gives a response according to

Description

the check result.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value

Generally, this functional switch is disabled by default, that is, it is

Configuration Reason

unnecessary to enable the support of this encryption algorithm.

Configuration Rule and

The BSS and the MSC must support the same encryption algorithm.

Adjustment Suggestion

This encryption algorithm is not supported currently.

Change Mode

Offline

Related features

None
4-234

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.12 Cipher Mode support A5/5 (CipherMode_0_5)


Full Name

Cipher Mode support A5/5

Abbreviation

CipherMode_0_5

3GPP Name

None

3GPP Reference

None
This parameter indicates the cipher mode supported by the cell. When the
MSC receives a BSSAP CIPHER MODE COMMAND, BSSAP ASSIGNMENT REQUEST, or BSSAP HANDOVER COMMAND message, which
specifying the required encryption algorithm, the BSC checks whether the
cell supports the encryption algorithm and gives a response according to

Description

the check result.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value

Generally, this functional switch is disabled by default, that is, it is

Configuration Reason

unnecessary to enable the support of this encryption algorithm.

Configuration Rule and

The BSS and the MSC must support the same encryption algorithm.

Adjustment Suggestion

This encryption algorithm is not supported currently.

Change Mode

Offline

Related features

None

4-235
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.13 Cipher Mode support A5/6 (CipherMode_0_6)


Full Name

Cipher Mode support A5/6

Abbreviation

CipherMode_0_6

3GPP Name

None

3GPP Reference

None
This parameter indicates the cipher mode supported by the cell. When the
MSC receives a BSSAP CIPHER MODE COMMAND, BSSAP ASSIGNMENT REQUEST, or BSSAP HANDOVER COMMAND message, which
specifying the required encryption algorithm, the BSC checks whether the
cell supports the encryption algorithm and gives a response according to

Description

the check result.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value

Generally, this functional switch is disabled by default, that is, it is

Configuration Reason

unnecessary to enable the support of this encryption algorithm.

Configuration Rule and

The BSS and the MSC must support the same encryption algorithm.

Adjustment Suggestion

This encryption algorithm is not supported currently.

Change Mode

Offline

Related features

None

4-236
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.14 Cipher Mode support A5/7 (CipherMode_0_7)


Full Name

Cipher Mode support A5/7

Abbreviation

CipherMode_0_7

3GPP Name

None

3GPP Reference

None
This parameter indicates the cipher mode supported by the cell. When the
MSC receives a BSSAP CIPHER MODE COMMAND, BSSAP ASSIGNMENT REQUEST, or BSSAP HANDOVER COMMAND message, which
specifying the required encryption algorithm, the BSC checks whether the
cell supports the encryption algorithm and gives a response according to

Description

the check result.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value

Generally, this functional switch is disabled by default, that is, it is

Configuration Reason

unnecessary to enable the support of this encryption algorithm.

Configuration Rule and

The BSS and the MSC must support the same encryption algorithm.

Adjustment Suggestion

This encryption algorithm is not supported currently.

Change Mode

Offline

Related features

None

4-237
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.15 Cipher mode priority1 ~ Cipher mode priority7


(CipherMode_1~ CipherMode_7)
Full Name

Cipher mode priority1 ~ Cipher mode priority7

Abbreviation

CipherMode_1~ CipherMode_7

3GPP Name

None

3GPP Reference

None
This parameter records the priority level of the current cipher mode supported by the cell. The smaller the parameter value is, the higher priority
the corresponding cipher mode has. For example, a cell is configured to
support three cipher modes: "Not support", "A5/1", and "A5/2". The value
of CipherMode_1 is set to 0, the value of CipherMode_2 is set to 1, and
the value of CipherMode_3 is set to 2. Then the priority levels of these

Description

three cipher modes fulfill this relation: "Not support" > "A5/1" > "A5/2".

Managed Object

Cell
0: Not support
1: A5/1
2: A5/2
3: A5/3
4: A5/4
5: A5/5
6: A5/6

Value Range and Step

7: A5/7

Unit

None

4-238
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value
Default Value
Configuration Reason

The default value of each cipher mode is 0 (Not support).


Each cipher mode is disabled by default. Negotiate with the CN to
set the cipher modes according to the actual situation. The cipher
algorithms from A5/4 to A5/7 are not supported now.

Configuration Rule and

Modify the parameter after negotiating with the CN. The cipher

Adjustment Suggestion

algorithms from A5/4 to A5/7 are not supported now.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

Yes

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.10.16 Channel Select Strategy (ChanSelectStrategy)


Full Name

Channel Select Strategy

Abbreviation

ChanSelectStrategy

3GPP Name

Internal

3GPP Reference

None
This parameter decides the channel allocation mode of each kind of high-

Description

priority users.

Managed Object

Cell

4-239
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Level (1..15). The value range is:


0: According to channel select order of MSC, when prefer TCHF and cell
congest (allocation threshold of HR is exceeded) change to prefer TCHH
1: Prefer TCHF, when cell congest (allocation threshold of HR is
exceeded), change to prefer TCHH
2: Prefer TCHH
3: TCHF only, not allocate TCHH
4: TCHH only, not allocate TCHF
5: According to channel select order of MSC, not consider whether cell
congest
6: According to channel select order of MSC, when prefer TCHF and cell
congest (allocation threshold of HR is exceeded) change to prefer TCHH
7: Prefer TCHF, not consider whether cell congest
8: Prefer TCHF, when cell congest (allocation threshold of HR is
exceeded), change to prefer TCHH if AMR-HR supported
9: Cell congest indicates whether the occupation of cell channels
Value Range and Step

reaches the threshold of TCHH.

Unit

None
level 1...15, the default value is: according to channel select order of MSC,

Default Value
Default Value
Configuration Reason

when prefer TCHF and cell congest change to prefer TCHH.


Generally, in accordance with the channel allocation strategy provided
by MSC, TCHH is preferentially allocated only in the case of channel
congestion.

Configuration Rule and

Generally, the parameter is configured for higher-priority users. It is set

Adjustment Suggestion

to be easily allocated with TCHH instead of only TCHF or only TCHH.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None
4-240

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.10.17 Info_3
Full Name

Info_3

Abbreviation

Info_3

3GPP Name

None

3GPP Reference

None

Description

This parameter is currently not used.

Managed Object

Cell

Value Range and Step

0..4294967295

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is currently not used.

Configuration Rule and


Adjustment Suggestion

This parameter is currently not used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell-> Other Params

Parameter Modifying
Version

iBSCV6.20.711c

Parameter Modifying
Detail

New

4.10.18 Info_4
Full Name

Info_4

Abbreviation

Info_4

3GPP Name

None

3GPP Reference

None
4-241

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Description

This parameter is currently not used.

Managed Object

Cell

Value Range and Step

0..4294967295

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is currently not used.

Configuration Rule and


Adjustment Suggestion

This parameter is currently not used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell-> Other Params

Parameter Modifying
Version

iBSCV6.20.711c

Parameter Modifying
Detail

New

4.10.19 Info_5
Full Name

Info_5

Abbreviation

Info_5

3GPP Name

None

3GPP Reference

None

Description

This parameter is currently not used.

Managed Object

Cell

Value Range and Step

0..4294967295

Unit

None

Default Value

0
4-242

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value
Configuration Reason

This parameter is currently not used.

Configuration Rule and


Adjustment Suggestion

This parameter is currently not used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell-> Other Params

Parameter Modifying
Version

iBSCV6.20.711c

Parameter Modifying
Detail

New

4.10.20 Info_6
Full Name

Info_6

Abbreviation

Info_6

3GPP Name

None

3GPP Reference

None

Description

This parameter is currently not used.

Managed Object

Cell

Value Range and Step

0..4294967295

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is currently not used.

Configuration Rule and


Adjustment Suggestion

This parameter is currently not used.

Change Mode

Offline

4-243
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell-> Other Params

Parameter Modifying
Version

iBSCV6.20.711c

Parameter Modifying
Detail

New

4.10.21 Info_7
Full Name

Info_7

Abbreviation

Info_7

3GPP Name

None

3GPP Reference

None

Description

This parameter is currently not used.

Managed Object

Cell

Value Range and Step

0..4294967295

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is currently not used.

Configuration Rule and


Adjustment Suggestion

This parameter is currently not used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

0
4-244

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell-> Other Params

Parameter Modifying
Version

iBSCV6.20.711c

Parameter Modifying
Detail

New

4.11 GPRS Basic Parameters


4.11.1 SGSN ID (SGSNID)
Full Name

SGSN ID

Abbreviation

SGSNID

3GPP Name

None

3GPP Reference

None
This parameter indicates the SGSN ID assigned in the BSC. It is assigned
when users create SGSN. It cannot be modified but can be deleted after

Description

creation.

Managed Object

Cell
1 .. 16

Value Range and Step

Step: 1

Unit

None

Default Value

The default value is dependent upon the actual configuration.

Default Value

Setting of the default value is in accordance with the ground parameter

Configuration Reason

planning value.

Configuration Rule and


Adjustment Suggestion

When users create the SGSN, the SGSN ID is assigned in the


BSC.Configuration of the value is in accordance with the ground
parameter planning value.

Change Mode

Offline

Related features

ZGO-05-02-007 Flex Gb Interface

Related Parameters

None

Relationship

None

Related Interfaces

Gb

4-245
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Basic


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.11.2 NSEI (NSEI)


Full Name

NSEI

Abbreviation

NSEI

3GPP Name

NSEI

3GPP Reference

3GPP TS 48.018
At the BSSGP layer of the GPRS protocol stack, every GPRS cell
is intentionally assigned a BSSGP virtual connection (BVC), that is,
NSEI+BVCI. One BVC must belong to a network service entity (NSE).
NSEI identifies the NSE with a unified code in the entire network.
Generally, one BSC is regarded as one service entity. In the light of
expandability, the ZXG10 system also allows BSC to be attached with
several NSEs.
This parameter can be configured only when users firstly configure the
NSE in "Relevant configuration at GB interface".

Description

This parameter value is consistent with the data at the CN side.

Managed Object

Cell
0 .. 65535

Value Range and Step

Step: 1

Unit

None
The default value is Dependent upon the NSE configuration at GB inter-

Default Value

face.

Default Value

Setting of the default value is in accordance with the ground parameter

Configuration Reason

planning value.

4-246
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

The code of NSE is a unified code in the entire network. The NSE is
Configuration Rule and

consistent with the data at the CN side and is dependent on the actual

Adjustment Suggestion

cell configuration. Configuration of the value is in accordance with the


ground parameter planning value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Basic

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.11.3 BVCI (BVCI)


Full Name

BVCI

Abbreviation

BVCI

3GPP Name

BVCI

3GPP Reference

3GPP TS 48.019
BSSGP Virtual Connection (BVC) provides an approach for
communication between different BSSGP entities. The point-to-point
(PTP) or point-to-multipoint (PTM) or inter-signaling entity transmission
of BSSGP PDUs is based on BVC.
Each virtual connection has one identifier, that is, BVCI. It enables the
network service layer at the bottom layer to route BSSGP PDUs to the
peer entity very effectively.Under one NSE, each GPRS cell can be
uniquely identified by the BVCI. One NSE carries only one signaling

Description

BVC (BVCI=0).

Managed Object

Cell

4-247
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

2 .. 65535
Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Setting of the default value is in accordance with the ground parameter

Configuration Reason

planning value.
Under one NSE, each GPRS cell can be uniquely identified by the BVCI.

Configuration Rule and


Adjustment Suggestion

One NSE carries only one signaling BVC (BVCI=0). The value should
not be adjusted and is dependent upon the actual cell configuration. This
parameter must be unique under one SGSN.If the configuration of this
parameter is incorrect, the PS services of the cell may be unavailable.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Basic

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.11.4 RAC (RAC)


Full Name

RAC

Abbreviation

RAC

3GPP Name

None

3GPP Reference

None

4-248
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

GPRS, similar to the GSM system which uses a location area to manage
a group of cells, performs its management by dividing a location area into
several routing areas identified by RAI (MCC+MNC+LAC+RAC). When
the MS in the attach status performs cell reselection, if the RAIs of the old
and new cells are changed, it initiates a "Routing Area Update" process.
SGSN knows the routing area information of the MS in the standby
status. In this case, when the network has packet data or circuit data
to transmit, it will page the MS in that routing area.One RAI cannot be
configured in several SGSNs.
Description

This parameter value is consistent with the data at the CN side.

Managed Object

Cell
0.. 255

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Configuration of the default value is in accordance with the starting value

Configuration Reason

of the value range.

Configuration Rule and

One RAI cannot be configured in several SGSNs. The value is

Adjustment Suggestion

consistent with the data at the CN side.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Basic


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-249
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.11.5 PS service busy level (PsBusyLevel)


Full Name

PS service busy level

Abbreviation

PsBusyLevel

3GPP Name

None

3GPP Reference

None
When UPU performs dynamic adjustment, it calculates the DSP load allocated to the cell according to the PS service level, and preferentially

Description

selects the DSP with small load to bind.

Managed Object

Cell
1..5

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

For the initial configuration cell, the load is the same by default.
This parameter configuration can be adjusted after the PS service traffic

Configuration Rule and


Adjustment Suggestion

of each cell is calculated in accordance with the performance statistics


data. The larger the value is, the busier the cell is, the higher is the
load of UPUDSP where the cell resides, the less is the cell configured
on the DSP.

Change Mode

Offline

Related features

ZGO-03-07-005 PCU Resource Flexible Sharing for Multiple Operators

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Basic


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-250
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.11.6 Enable cell PS push down (PSPushDown)


Full Name

Enable cell PS push down

Abbreviation

PSPushDown

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether the cell allows the PS services to be
pushed down. That is, when the bandwidth measured at the Abis interface
exceeds the bandwidth upper limit of the stable area in the Abis resource

Description

pool, the coding scheme of the PS services should be reduced or not.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Default Value

The default value is disabled in BSC and enabled in the cell by default. It

Configuration Reason

is convenient for enabling the function.

Configuration Rule and

If the PS service push-down function should be enabled for a cell on site,

Adjustment Suggestion

set the parameter value to 1; if not, set the parameter value to 0.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Basic

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-251
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.12 GPRS Other Parameters 1


4.12.1 Additional reselection parameter indicator (AddResPI2)
Full Name

Additional reselection parameter indicator

Abbreviation

AddResPI2

3GPP Name

None

3GPP Reference

None
The cell selection and reselection of MS depends on the C1 and C2
parameters, according to the definition in the GSM specifications.
Network operators decide whether to use C2 as the cell reselection
parameter.
Additional reselection parameter indication is to notify MS whether C2
criterion is adoptable during the cell reselection.
Through the RIL3_RR SYSTEM INFORMATION TYPE3 and TYPE4
messages, this parameter information is broadcast to the MS in the cell.
It is one of the cell selection parameters.
The values are as follows:
No: If the rest bytes (SI4 Rest Octets) of SYSTEM INFORMATION
TYPE4 is available, MS should obtain the cell reselection parameter PI
and the parameters related to the computation of C2 from the rest bytes.
Yes: MS should obtain the PI parameter related to the cell reselection
and parameters related to the computation of C2 from the rest bytes
(SI7/8 Rest Octets) of the SYSTEM INFORMATION TYPE7 or 8
message.
Generally, the system messages TYPE 7 and TYPE 8 are rarely used.
This parameter must be set as No, otherwise some MSs (for example

Description

NEC) are unable to access the network.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

Generally, system messages TYPE 7 and TYPE 8 are rarely used. This
parameter must be set as No, otherwise some MSs (for example NEC)
are unable to access the network.
Generally, system messages TYPE 7 and TYPE 8 are rarely used. This
parameter must be set as No, otherwise some MSs (for example NEC)
are unable to access the network.

Change Mode

Offline

Related features

None

4-252
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


parameters 1
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.12.2 SI13 sending position (Si13Locate)


Full Name

SI13 sending position

Abbreviation

Si13Locate

3GPP Name

None

3GPP Reference

None
This parameter is used at the MS side. This parameter information is
broadcast to the MS in SI3, SI4, SI7, SI8, SI13, and PSI3 of the adjacent
cell, indicating the scheduling position of SI13 on BCCH.
The system message 13 is only related to the GPRS service, and it can
be sent on the BCCH Norm position (in this case, the BCCH block with
TC = 4 is occupied; TC = (FN DIV 51) mod (8))), or on the BCCH Ext
position (in this case, a fixed AGCH block with TC = 0 is occupied).
SI13 is seldom sent successfully on the BCCH Ext position because
it has to compete with other messages (for example, immediate
assignment message) for the sending opportunity. In this case,
the parameter value of "Number of blocks reserved for AGCH"
("BsAgBlkRes" in the R_BTS table) must be greater than 0. Otherwise,

Description

SI13 has no opportunity to be sent.

Managed Object

Cell

Value Range and Step

BCCH Norm, BCCH Ext

Unit

None

Default Value

BCCH Norm

4-253
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

The default value is dependent upon the protocol recommended value.

Configuration Rule and

The value BCCH Norm is dependent upon the protocol recommended

Adjustment Suggestion

value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.12.3 Route area color code (RaColor)


Full Name

Route area color code

Abbreviation

RaColor

3GPP Name

RA COLOUR

3GPP Reference

3GPP TS 44.018
This parameter is used at the MS side. It is broadcast to the MS in SI3,
SI4, SI7 and SI8. The function of RaColor is similar to that of the BCC
in the GSM system. In some cases, such as inter-BSC cell reselection,
the GPRS network assigns different RaColor values to the adjacent cell
with the same route area code to ensure that the MS can initiate the
Routing Area Updating process.
In this way, when receiving different RaColor values in the cells with the
same routing area code, the MS will originate the "Routing Area Update"

Description

process like spanning two different routing areas.

Managed Object

Cell

4-254
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

0 .. 7
Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Generally, RAC and LA are consistent with each other. The value is

Configuration Reason

set to 0 by default.

Configuration Rule and

Generally, RAC and LA are consistent with each other. It is

Adjustment Suggestion

recommended to set the value as 0.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.12.4 Minimal number of idle CS channel (CsChansThs)


Full Name

Minimal number of idle CS channel

Abbreviation

CsChansThs

3GPP Name

None

3GPP Reference

None

4-255
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Idle CS channels (including the idle and dynamic TCH channel, and the
static TCH channel) are reserved in the cell for reducing CS call failure
rate.After the CS channel has been applied for successfully, if the number
of idle CS channels in the current cell is smaller than the threshold, try to
perform such operations as starting intelligent powerup or releasing the
PS channel forcibly, so as to ensure the number of idle CS channels is
Description

greater than the threshold.

Managed Object

Cell
0..255

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default value is used to reduce CS call failure rate, and ensure
that each time idle channels are available for CS request to access
successfully.

Configuration Rule and


Adjustment Suggestion

It is recommended not to adjust the configuration of this parameter value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.12.5 Packet access priority threshold (PriAcThr)


Full Name

Packet access priority threshold

Abbreviation

PriAcThr
4-256

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

3GPP Name

PRIORITY_ACCESS_THR

3GPP Reference

3GPP TS44.018 V5.22.0


This parameter is used at the MS side. It is broadcast to the MS in the
PSI13 and SI13 messages, indicating the priority level of MS packet access allowed by the cell. Its function is similar to the function of ACCESS

Description

CLASS.

Managed Object

Cell
Packet access is not allowed, packet access is allowed for priority 1,
packet access is allowed for priority 1-2, packet access is allowed for
priority 1-3, packet access is allowed for priority 1-4 , packet access is

Value Range and Step

allowed.

Unit

None

Default Value

Packet access is allowed for priority level 1-4.

Default Value
Configuration Reason

Generally, packet access is allowed.

Configuration Rule and

If the packet access of users should be limited by the service priority, the

Adjustment Suggestion

value should be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-257
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.12.6 Packet System Information Send Speed (SendSpeed (PSI2,


PSI3, PSI3BIS, PSI4, PSI5, PSI13, PSI3ter, PSI8, PSI3quater))
Full Name

Packet System Information Send Speed

Abbreviation

PSI3quater)

3GPP Name

None

3GPP Reference

None

SendSpeed (PSI2, PSI3, PSI3BIS, PSI4, PSI5, PSI13, PSI3ter, PSI8,

This parameter is used for the global process on BRP to indicate whether
the various types of PSI messages are sent at a high rate. The number
of packet system messages (16) sent at a high rate is limited, and the
number of sent messages of each type varies from the length of the
message, so the user can only figure out the approximate requirement
for the sending speed of of each type of system message.
Before the message is sent, the global process dynamically specifies
the sending rate for each type of packet system message according
to the users' requirement (accordingly analyze the array subscript of
Description

SendSpeed )and system limitation.

Managed Object

Cell

Value Range and Step

The value range is of 9 types and the value is: Yes, No

Unit

None

Default Value

[Yes, Yes, Yes, Yes, Yes, Yes, Yes, Yes, Yes]

Default Value
Configuration Reason

This parameter is related to PBCCH. The default value is reserved.

Configuration Rule and

This parameter is related to PBCCH. It is recommended not to adjust

Adjustment Suggestion

the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


parameters 1

4-258
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.12.7 Overload report period on PRACH (OvLoadPer)


Full Name

Overload report period on PRACH

Abbreviation

OvLoadPer

3GPP Name

None

3GPP Reference

None
This parameter is used at the BTS side. BSC notifies BTS to report the

Description

interval of PRACH overload period.

Managed Object

Cell
0 .. 255

Value Range and Step

Step: 1

Unit

Default Value

10

Default Value
Configuration Reason

This parameter is related to PBCCH. The default value is reserved.

Configuration Rule and

This parameter is related to PBCCH. It is recommended not to adjust

Adjustment Suggestion

the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


parameters 1

Parameter Modifying
Version

None

4-259
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

4.12.8 Link error counter (RLTimeout)


Full Name

Link error counter

Abbreviation

RLTimeout

3GPP Name

None

3GPP Reference

None
BTS uses this parameter. BSC inform the parameter through O&M message to update the counter when BTS cannot decode RLC Block in GPRS

Description

data.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

20

Default Value
Configuration Reason

This parameter is relevant to PBCCH. Keep the default setting.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


parameters 1
Parameter Modifying
Version

None

Parameter Modifying
Detail

None
4-260

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.12.9 PRACH receiving signal level threshold (PrachBusyT)


Full Name

PRACH receiving signal level threshold

Abbreviation

PrachBusyT

3GPP Name

None

3GPP Reference

None
This parameter is used by BTS.PRACH channel overload is one of the
causes for overload control. The busy ratio of random access burst
decides the PRACH overload.
If a bursts level exceeds the level value specified by this parameter, the

Description

burst is considered as a busy burst.

Managed Object

Cell
0 .. 63
00: < -110 dBm;
1: -110 dBm .. -109 dBm;
2: -109 dBm .. -108 dBm;
......
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

63

Default Value
Configuration Reason

This parameter is related to PBCCH. The default value is reserved.

Configuration Rule and

This parameter is related to PBCCH. It is recommended not to adjust

Adjustment Suggestion

the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


parameters 1

4-261
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.12.10 Average measuring bursts number on PRACH (MeaAvgSlot)


Full Name

Average measuring bursts number on PRACH

Abbreviation

MeaAvgSlot

3GPP Name

None

3GPP Reference

None
This parameter is used by BTS. It indicates the number of bursts measured on PRACH. The PRACH channel overloads if the receiving signal
levels of AvgSlots BPs are lower than PrachBusyT. It is one of the parameters used by BTS. If this parameter is modified, the BTS needs to be

Description

synchronized.

Managed Object

Cell
0 .. 100

Value Range and Step

Step: 1

Unit

None

Default Value

60

Default Value
Configuration Reason

This parameter is related to PBCCH. The default value is reserved.

Configuration Rule and

This parameter is related to PBCCH. It is recommended not to adjust

Adjustment Suggestion

the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


parameters 1
4-262
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.12.11 Buffer threshold of paging message (PccchIndTh_0)


Full Name

Buffer threshold of paging message

Abbreviation

PccchIndTh_0

3GPP Name

None

3GPP Reference

None
This parameter indicates the overload threshold of paging message buffer
for PPCH. The judgment scheme is as follows: i.Calculate the paging
message buffer corresponding to a paging channel. ii.Divide the number of messages stored in the buffer by the maximum storage amount.
iii.Multiply the obtained percentage by 100. Compare the result with the
threshold. If the result exceeds the threshold, the PPCH is considered as

Description

overload.

Managed Object

Cell
0 .. 100

Value Range and Step

Step: 1

Unit

Default Value

50

Default Value
Configuration Reason

This parameter is related to PBCCH. The default value is reserved.

Configuration Rule and

This parameter is related to PBCCH. It is recommended not to adjust

Adjustment Suggestion

the value.

Change Mode

Offline

Related features

ZGB-02-01-001 paging

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

4-263
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.12.12 Queue length threshold in 64 multi-frame paging period


(PccchIndTh_1)
Full Name

Queue length threshold in 64 multi-frame paging period

Abbreviation

PccchIndTh_1

3GPP Name

None

3GPP Reference

None
This parameter is used by BTS. It indicates the overload threshold on
PCCCH (PRACH, PPCH). This parameter is an array with 3 elements,
in the unit of %.
PccchIndTh[1]: The paging group overload threshold of PPCH. The
judgment scheme is as follows: i.Accumulate the paging message which
is to be sent in the buffer queue corresponding to each paging group.
ii.Divide the number of messages stored in the buffer by the maximum
storage amount. iii.Multiply the obtained percentage by 100. Compare
the result with the threshold. If the result exceeds the threshold, the

Description

PPCH is considered as overload.

Managed Object

Cell
0 .. 100

Value Range and Step

Step: 1

Unit

Default Value

50

Default Value
Configuration Reason

This parameter is related to PBCCH. The default value is reserved.

Configuration Rule and

This parameter is related to PBCCH. It is recommended not to adjust

Adjustment Suggestion

the value.

Change Mode

Offline

Related features

ZGB-02-01-001 paging

Related Parameters

None

4-264
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.12.13 PRACH overload threshold ratio (PccchIndTh_2)


Full Name

PRACH overload threshold ratio

Abbreviation

PccchIndTh_2

3GPP Name

None

3GPP Reference

None
The number of busy blocks on one PRACH divides the total number of
blocks on this PRACH, and then multiplies 100. If the result exceeds this

Description

threshold, the PRACH is consided as overload.

Managed Object

Cell
0 .. 100

Value Range and Step

Step: 1

Unit

Default Value

50

Default Value
Configuration Reason

This parameter is related to PBCCH. The default value is reserved.

Configuration Rule and

This parameter is related to PBCCH. It is recommended not to adjust

Adjustment Suggestion

the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

4-265
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13 GPRS Other Parameters 2


4.13.1 DTM support (DTMSupport)
Full Name

DTM support

Abbreviation

DTMSupport

3GPP Name

None

3GPP Reference

None
This parameter information is broadcast to the MS in the GPRS Cell options of SI13, PSI1 and PSI13. It indicates whether the cell supports Dual
Transfer Mode (DTM) which allows the class-A MS to initialize packet re-

Description

quest flow in dedicated mode.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


If CN supports Common ID, whether to enable the DTM function is
dependent upon users' requirement of the current network. The function
supports concurrent services and users' felling can be improved.

Change Mode

Offline

Related features

ZGO-01-03-005 Dual Transfer Mode

4-266
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

[Cell]GttpLapdmNum

Relationship

GttpLapdmNum is valid after the DTMSupport function is enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.2 DTM Enhance Capability (DTMEnhanceCapa)


Full Name

DTM Enhance Capability

Abbreviation

DTMEnhanceCapa

3GPP Name

None

3GPP Reference

None
This parameter determines whether the cell supports enhanced DTM
functions. If yes, the MS establishes the DTM service without releasing

Description

the current PS service.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

These functions are not provided in the current version.

Configuration Rule and

It is required to configure this parameter according to the DTM settings

Adjustment Suggestion

and the functions supported by the current version.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]DTMEnhanceCap

4-267
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

This parameter is valid after the switch of enhanced DTM functions for
the BSC is enabled.

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.3 CCN mode support (CCNActive)


Full Name

CCN mode support

Abbreviation

CCNActive

3GPP Name

CCN_ACTIVE

3GPP Reference

3GPP TS44.060 V5.19.0


The network uses the parameter CCN_ACTIVE in the GPRS Cell
Options IE of SI13 on the BCCH to indicate the cell whether CCN
is enabled for cell reselection towards its adjacent cells.CCN mode
indicates that the MS notifies the network of cell reselection through the
PACKET CELL CHANGE NOTIFICATION message when it determines
to perform cell reselection.When the GPRS Cell Options IE does not
contain the CCN_ACTIVE parameter, or the CCN_ACTIVE parameter is
not enabled, the MS will not enter CCN mode.When the CCN_ACTIVE
parameter is enabled in the cell and the MS decides to reselect to the
adjacent cell, check whether the parameter CCN_SUPPORTED of the
adjacent cell is available:
If the parameter CCN_SUPPORTED does not exist, the MS is supposed
to use CCN mode for all adjacent cells;
If the parameter CCN_SUPPORTED exists and CCN mode is not
enabled, the MS cannot enter CCN mode;
If the parameter CCN_SUPPORTED exists and CCN mode is enabled,
the MS enters CCN mode.
Through the Packet Measurement Order message, the Packet Cell
Change Order message, or the PS Handover Command message, the

Description

network side can specify the special MS whether to enable the parameter
4-268

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

CCN_ACTIVE of the serving cell. The parameter CCN_ACTIVE sent on


PACCH takes priority over that broadcast by the system message. The
MS uses CCN mode only under NC0 and NC1 modes.
Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


If the function is enabled, it helps reduce the interval of cell reselection
and brings less impact on the current packet services. Therefore, it is
recommended to enable the function.

Change Mode

Offline

Related features

ZGO-02-02-010 Network-assisted Cell Change

Related Parameters

[BSC]NACCSupport
[Cell]CCNActive
[Cell]SIStatusInd

Relationship

NACC should be enabled simultaneously with CCNActive/SIStatusInd/CCNSupport.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.4 Cell support system message status flow (SIStatusInd)


Full Name

Cell support system message status flow

Abbreviation

SIStatusInd

3GPP Name

SI_STATUS_IND

3GPP Reference

3GPP TS44.060 V5.19.0


4-269

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates whether the cell supports the system message
status flow, and is broadcast to the MS in SI13 and PSI13. It describes
whether the network supports the Packet SI Status process. The MS notifies network about the current receiving status of the saved SI message
through sending the Packet SI Status message on PACCH. The network
sends the SI message to the MS in accordance with the receiving status
of SI after it receives the Packet SI Status message.During cell reselection assisted by the network, once all the required system information
messages have been received and the new cell supports the PACKET SI
STATUS procedures, the MS may perform access to the new cell and use
Description

the previous procedures to obtain the system message of a new cell.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


If the function is enabled, it helps restore services as soon as possible
after the MS reselects to a new cell. Therefore, it is recommended to
enable the function.

Change Mode

Offline

Related features

ZGO-02-02-010 Network-assisted Cell Change

Related Parameters

[BSC]NACCSupport
[Cell]CCNSupport
[Cell]CCNActive

Relationship

NACC should be enabled simultaneously with CCNActive/SIStatusInd/CCNSupport.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-270
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.13.5 Allow SOLSA MS to access (Exc_Acc)


Full Name

Allow SOLSA MS to access

Abbreviation

Exc_Acc

3GPP Name

EXC_ACC

3GPP Reference

3GPP TS 44.060 V5.19.0


When PBCCH is configured, this parameter information is broadcast
to the MS through the PSI3 and PSI3bis system messages. When
PBCCH does not exist, it is broadcast to a certain MS through the
PACKET CELL CHANGE ORDER message on PACCH or the PACKET
MEASUREMENT ORDER message. This parameter is used by the
network to prevent the MS without SoLSA exclusive access rights from
camping on the cell.
0: The MS with SoLSA exclusive access rights is prohibited from
accessing.
1: The MS with SoLSA exclusive access rights is allowed to access.
SoLSA: SoLSA (Support of Localised Service Area) is the local serving
area consisting of a cell or a series of cells. The coverage of these cells

Description

can be discontinuous.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

Generally, the MS without SoLSA exclusive access rights is allowed

Configuration Reason

to camp on the cell.

Configuration Rule and


Adjustment Suggestion

The value is dependent upon the operator's requirement and network


planning. If the cell which wishes the MS with SoLSA exclusive access
rights to access, the value is Yes. Otherwise, the value is No.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-271
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.6 CCCH SplitPGCycle support (SpgcSuport)


Full Name

CCCH SplitPGCycle support

Abbreviation

SpgcSuport

3GPP Name

SPLIT_PG_CYCLE

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at the MS side and BTS side. It is broadcast
to the MS in the PSI13 and SI13 messages, and sent to BTS in the
Setting BTS Attribute message. It indicates whether the cell supports
PLIT_PG_CYCLE on CCCH. The MS carries the Whether to Support
Split on CCCH field in the DRX parameter of the GPRS ATTACH
message, and asks for negotiating the value of SPLIT_PG_CYCLE with
CN.When the MS and the cell support split, the "PACKET IMMEDIATE
ASSIGNMENT", "PACKET PAGING" and "PACKET IMMEDIATE
ASSIGNMENT REJECT" messages can be sent on multiple BLOCKs.
The position of the blocks is determined by the calculation formula of
paging groups:
PAGING_GROUP (0...M-1) = ( ( (IMSI mod 1000) div(KC*N) * N +
(IMSI mod 1000) mod N + Max( (m*M)div SPLIT_PG_CYCLE, m) )mod
M
Where,
KC = BS_CC_CHANS ( number of CCCHs in the cell)
M = number of available paging blocks on CCCH
= (9-BS_AG_BLKS_RES)*64 (CCCH and SDCCH not combined)
= (3-BS_AG_BLKS_RES)*64 (CCCH and SDCCH combined)
N = (9-BS_AG_BLKS_RES)*BS_PA_MFRMS (CCCH and SDCCH not
combined)
=(3-BS_AG_BLKS_RES)*BS_PA_MFRMS (CCCH and SDCCH
combined)
SPLIT_PG_CYCLE is the value negotiated between the MS and CN

Description

during GPRS attach.

Managed Object

Cell

4-272
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


This function should be supported by the MS, the value should be
negotiated with CN and influences the calculation of MS paging groups,
so it is recommended not to enable the function.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.7 Extended paging support (EpageMode)


Full Name

Extended paging support

Abbreviation

EpageMode

3GPP Name

extended paging

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter information is one of the page modes, indicating whether
to support extended paging.Extended paging means that MS still can receive and analyze the message within the 3rd interval after the block is

Description

indicated by its paging group.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No
4-273

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


The extended paging mode is configured to relieve the temporary
overload of a subchannel. The mode enables a paging message, which

Configuration Rule and

is usually transmitted over a paging subchannel (PCH BLOCK) of the

Adjustment Suggestion

CCCH, to be transmitted over the next paging block.If the temporary


overload exists, you can set the value. Generally, it is unnecessary to
set the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.8 PSI status support (PsiStatInd)


Full Name

PSI status support

Abbreviation

PsiStatInd

3GPP Name

PSI_STATUS_IND

3GPP Reference

3GPP TS 44.060 V5.19.0

4-274
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter indicates whether the cell supports the system message
status flow, and is broadcast to the MS in PSI1 on PBCCH. It describes
whether the network supports the Packet SI Status process. The MS notifies network about the current receiving status of the saved SI message
through sending the Packet SI Status message on PACCH. The network
sends the SI message to the MS through the Packet Serving Cell Data
message in accordance with the receiving status of SI after it receives
the Packet SI Status message.During cell reselection assisted by the network, once all the required system information messages have been received and the new cell supports the PACKET SI STATUS procedures,
the MS may perform access to the new cell and use the previous proceDescription

dures to obtain the system message of a new cell.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

This parameter is related to the configuration of PBCCH channel, so it is

Configuration Reason

recommended not to use the value.

Configuration Rule and


Adjustment Suggestion

It is recommended to configure the value as No.

Change Mode

Offline

Related features

ZGO-02-02-010 Network-assisted Cell Change

Related Parameters

[BSC]NACCSupport
[Cell]CCNSupport
[Cell]CCNActive

Relationship

NACC should be enabled simultaneously with CCNActive/SIStatusInd/CCNSupport.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-275
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.13.9 Cell support extendable uplink TBF (Ext_UTBF)


Full Name

Cell support extendable uplink TBF

Abbreviation

Ext_UTBF

3GPP Name

NW_EXT_UTBF

3GPP Reference

tocol"

TS44.060: "Radio Link Control/Medium Access Control (RLC/MAC) pro-

This parameter indicates whether the cell supports the extended uplink
TBF. After BSS receives the uplink block (CV=0), if the cell supports
the extended uplink TBF, it enters into the extended uplink TBF status.
At this time, it continues to assign uplink block resources to the MS.
If new uplink data is required to send during the extended uplink,
re-establishment of uplink TBF is not required.
This function requires the extended uplink function should be supported
Description

at the MS side as well.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value

According to MS' capability and the network traffic model, it is

Configuration Reason

recommended to enable the default value.


According to the TBF data transmission condition, set whether TBF

Configuration Rule and


Adjustment Suggestion

continues to wait for data transmission after the last data block of the
TBF is successfully transmitted, to avoid the re-setup of the TBF, reduce
the back-and-forth delay, and accelerate the transmission of the uplink
data. ()

Change Mode

Offline

Related features

ZGB-03-05-014 Delayed TBF Release in UL

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters 2

4-276
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.10 Uplink delay time (UlDelayTime)


Full Name

Uplink delay time

Abbreviation

UlDelayTime

3GPP Name

None
TS44.060: "Radio Link Control/Medium Access Control (RLC/MAC) pro-

3GPP Reference

tocol"
This parameter describes the uplink TBF delay time. When the uplink
TBF is released, if the extended uplink TBF function is not supported,
start this timer to access to the uplink delay state and wait for the arrival

Description

of the downlink LLC. The uplink TBF is released if the timer expires.

Managed Object

Cell
0 ..4000

Value Range and Step

Step: 1

Unit

ms

Default Value

1000

Default Value

The default value is dependent upon the downlink delay time at the

Configuration Reason

Gb interface.

Configuration Rule and


Adjustment Suggestion

The value is dependent upon the downlink delay time at the Gb interface.
If the delay time is long and the interval between the uplink and downlink
data transmission is long, increase the delay time as needed.

Change Mode

Offline

Related features

ZGB-03-05-014 Delayed TBF Release in UL

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-277
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.11 Interval number of GPRS TBF downlinks RRBP


(GPRSDIRrbpInterVal)
Full Name

Interval number of GPRS TBF downlinks RRBP

Abbreviation

GPRSDIRrbpInterVal

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the interval that the downlink Gprs TBF requires

Description

the MS to send Packet Downlink Ack/Nack.

Managed Object

Cell
3..20

Value Range and Step

Step: 1

Unit

RLC Block

Default Value

10

Default Value

In the radio network where the downlink voice RQ0..5 occupies about

Configuration Reason

97%, it is recommended to set the default value as 10.


The smaller the value is, the fewer the GPRS services are, the faster
the downlink received bitmap information of the MS can be notified to
BSC, and the more the uplink signalling blocks are occupied. The larger

Configuration Rule and

the value is, the more the GPRS services are, the slower the downlink

Adjustment Suggestion

received bitmap information of the MS can be notified to BSC, and the


fewer the uplink signalling blocks are occupied, which helps reduce
the retransmission rate of the signalling blocks at the RLC layer. If no
special requirement, the value should not be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um
4-278

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.12 Interval number of downlink EGPRS TBFs RRBP


(EGPRSDIRrbpInterVal)
Full Name

Interval number of downlink EGPRS TBFs RRBP

Abbreviation

EGPRSDIRrbpInterVal

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the interval that the downlink EGPRS TBF re-

Description

quires the MS to send EGPRS Packet Donwlink Ack/Nack.

Managed Object

Cell
6..60

Value Range and Step

Step: 1

Unit

RLC Block

Default Value

10

Default Value

In the radio network where the downlink voice RQ0..5 occupies about

Configuration Reason

97%, it is recommended to set the default value as 10.


The smaller the value is, the fewer the EDGE services are, the faster
the downlink received bitmap information of the MS can be notified to
BSC, and the more the uplink signalling blocks are occupied. The larger

Configuration Rule and

the value is, the more the EDGE services are, the slower the downlink

Adjustment Suggestion

received bitmap information of the MS can be notified to BSC, and the


fewer the uplink signalling blocks are occupied, which helps reduce
the retransmission rate of the signalling blocks at the RLC layer. If no
special requirement, the value should not be adjusted.

Change Mode

Offline

Related features

None

4-279
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.13 Interval number of uplink GPRS TBFs ACK


(GPRSUlAckInterVal)
Full Name

Interval number of uplink GPRS TBFs ACK

Abbreviation

GPRSUlAckInterVal

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the interval that the uplink GPRS TBF network

Description

sends packet uplink ACK/Nack to the MS.

Managed Object

Cell
3..20

Value Range and Step

Step: 1

Unit

RLC Block

Default Value

10

Default Value

In the radio network where the downlink voice RQ0..5 occupies about

Configuration Reason

97%, it is recommended to set the default value as 10.

4-280
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

The smaller the value is, the fewer the GPRS services are, the faster
the uplink received bitmap information of the MS can be notified to BSC,
Configuration Rule and
Adjustment Suggestion

and the more the downlink signalling blocks are occupied. The larger the
value is, the more the GPRS services are, the slower the uplink received
bitmap information of the MS can be notified to BSC, and the fewer
the downlink signalling blocks are occupied. If no special requirement,
the value should not be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.14 Interval number of uplink EGPRS TBFs ACK


(EGPRSUlAckInterVal)
Full Name

Interval number of uplink EGPRS TBFs ACK

Abbreviation

EGPRSUlAckInterVal

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the interval that the uplink EGPS TBF network

Description

sends packet uplink Ack/Nack to the MS.

Managed Object

Cell
3..20

Value Range and Step

Step: 1

Unit

RLC Block

4-281
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value

In the radio network where the downlink voice RQ0..5 occupies about

Configuration Reason

97%, it is recommended to set the default value as 8.


The smaller the value is, the fewer the EDGE services are, the faster
the uplink received bitmap information of the MS can be notified to BSC,

Configuration Rule and


Adjustment Suggestion

and the more the downlink signalling blocks are occupied. The larger the
value is, the more the EDGE services are, the slower the uplink received
bitmap information of the MS can be notified to BSC, and the fewer
the downlink signalling blocks are occupied. If no special requirement,
the value should not be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.15 Single block assign offset (Info1_0_0)


Full Name

Single block assign offset

Abbreviation

Info1_0_0

3GPP Name

None

3GPP Reference

None
During the uplink two-phase access, the MS initiates channel request,
and the network side allocates single resource block to the MS. This pa-

Description

rameter indicates the searching range of this resource block.

Managed Object

Cell

4-282
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

6..12
Value Range and Step

Step: 1

Unit

None

Default Value

10

Default Value

The default value 10 fulfills normal delay requirements and is dependent

Configuration Reason

upon the delay between the MS and BSC.

Configuration Rule and


Adjustment Suggestion

The value is dependent upon the delay between the MS and BSC. If
the delay time is long, set the value as large. Otherwise, set the value
as small.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.16 Polling retry times (Info1_0_8)


Full Name

Polling retry times

Abbreviation

Info1_0_8

3GPP Name

None

3GPP Reference

None

Description

The network side can send the maximum number of pollings to the MS
when it does not receive any response from the MS. After the maximum
number is reached, the MS instance is released to confirm the interval
of pollings and which polling making no sense.

Managed Object

Cell
4-283

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Value Range and Step

3..12
Step: 1

Unit

None

Default Value

12

Default Value

The default value is dependent upon the valid LLC frame and cell

Configuration Reason

reselection.

Configuration Rule and

The value is dependent upon the valid LLC frame, cell reselection and

Adjustment Suggestion

radio signal quality. If the radio signal quality is poor and cell reselection
takes a long time, increase the value as needed. Otherwise, reduce
the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other
Parameters 2

Parameter Modifying

None

Version
Parameter Modifying

None

Detail

4.13.17 Uplink measurement report period (Ulmeasureperiod)


Full Name

Uplink measurement report period

Abbreviation

Ulmeasureperiod

3GPP Name

None

3GPP Reference

None
This parameter is used by UPPB, describing the uplink measurement report period reported by BTS and handled by BSC. The BTS obtains the

Description

measurement report according to the uplink level and quality of the MS.

Managed Object

Cell

4-284
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

400 ..2000
Value Range and Step

Step: 1

Unit

ms

Default Value

800

Default Value

The default value is dependent upon the number of the received

Configuration Reason

measurement reports, and the window size.

Configuration Rule and

The value is dependent upon the number of the received measurement

Adjustment Suggestion

reports, and the window size.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.18 Calculating period of load on PPCH (LoadPer)


Full Name

Calculating period of load on PPCH

Abbreviation

LoadPer

3GPP Name

None

3GPP Reference

None
This parameter is used by FUC at the BTSside, describing the period of

Description

calculating the load on the PPCH channel.

Managed Object

Cell
0..16

Value Range and Step

Step: 1

4-285
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

Default Value

10

Default Value
Configuration Reason

This parameter is related to PBCCH.

Configuration Rule and


Adjustment Suggestion

This parameter is related to PBCCH and the value is not adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.19 PSI1 sending period (Psi1RepPer)


Full Name

PSI1 sending period

Abbreviation

Psi1RepPer

3GPP Name

PSI1_REPEAT_PERIOD

3GPP Reference

TS44.018: "Radio Resource Control (RRC) protocol"


This parameter is used at the MS side and FUC side. This parameter
information is broadcast to the MS through PST1, PST3 and ST13 messages of local and adjacent cells, indicating the sending period and destination of the PST1 message in a cell. The PSI1 message contains the information of cell reselection, PRACH control, control channel description,
and possible global power control parameters. As long as the PBCCH

Description

exists, the message is always sent at high repetition rate.

Managed Object

Cell

4-286
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

0..15
00: The PSI1 repeat period is equal to 1 multiframe;
1: The PSI1 repeat period is equal to 2 multiframes;
......
Value Range and Step

15: The PSI1 repeat period is equal to 16 multiframes;

Unit

Default Value

Default Value

The MS updates the system message instantly without repeating

Configuration Reason

frequently.

Configuration Rule and

The MS updates the system message instantly without repeating

Adjustment Suggestion

frequently.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.20 USF granularity (USFGranularity)


Full Name

USF granularity

Abbreviation

USFGranularity

3GPP Name

USF_GRANULARITY
TS44.060: "Radio Link Control/Medium Access Control (RLC/MAC) pro-

3GPP Reference

tocol"

4-287
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter information is assigned to the MS in the PACKET UPLINK ASSIGNMENT message, indicating that the network allocates uplink block granularity for the GPRS MS when the cell uses the medium
Description

control mode of dynamic allocation.

Managed Object

Cell
0..1
00: allocation granularity for the uplink block is 1;

Value Range and Step

1: allocation granularity for uplink block is 4

Unit

None

Default Value

Default Value

The default value is dependent upon the block utilization and GPRS

Configuration Reason

traffic model.

Configuration Rule and

The value is dependent upon the block utilization, uplink and downlink

Adjustment Suggestion

data transmission, and radio resources.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.21 Extended uplink dynamic allocation support


(ExUpDynSupport)
Full Name

Extended uplink dynamic allocation support

Abbreviation

ExUpDynSupport

3GPP Name

EXTENDED_DYNAMIC_ALLOCATION
4-288

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

TS44.060: "Radio Link Control/Medium Access Control (RLC/MAC) pro3GPP Reference

tocol"
This parameter indicates whether the cell supports the extended uplink
dynamic allocation. With this function, the MS only needs to monitor the
USF allocation with the smallest-number timeslot, to decide whether to

Description

send uplink block on all allocated uplink timeslots.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The default value is dependent upon the user traffic model and resources

Configuration Reason

utilization in the network.


The value is dependent upon the function supported by the MS, PS

Configuration Rule and


Adjustment Suggestion

service data transmission on the uplink, and uplink radio resources.


If the transmission on the uplink takes priority or uplink resources are
adequate, the uplink transmission rate can be improved with this function
enabled.

Change Mode

Offline

Related features

ZGO-03-02-007 Extended Dynamic Allocation

Related Parameters

[BSC]ExUpDynSupport

Relationship

This parameter is valid if the BSC-level parameter is enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.22 ABIS time slots reserved for packet service (Info_1_0)


Full Name

ABIS time slots reserved for packet service

4-289
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

Info_1_0

3GPP Name

None

3GPP Reference

None
The PS services in the cell are allocated with a minimum number of Abis
timeslots to ensure that the PS services can obtain a single block and can
be accessed, and some of the ABIS resources in the cell can be used as
PS. Generally, it is recommended not to modify this parameter value. This

Description

parameter is invalid if the interface of Abis is an IP interface.

Managed Object

BSC
0..255

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default value is to ensure the basic access of PS services in the cell,
and to prevent the cell from the failure of implementing any PS service
due to the ABIS resouces are occupied by other cells.

Configuration Rule and


Adjustment Suggestion

It is recommended not to adjust the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-290
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.13.23 The MAX of ABIS for GPRS user (Info_1_8)


Full Name

The MAX of ABIS for GPRS user

Abbreviation

Info_1_8

3GPP Name

None

3GPP Reference

None
This parameter indicates the maximum number of Abis resources bound
for PS channels newly allocated for the GPRS user when the Abis
resources in the cell are adequate.
This parameter value is valid if the carrier supports EDGE and the
service type applied for is GPRS.
If the carrier supports EDGE and the service type applied for is EDGE,
allocate Abis in accordance with the bandwidth of a maximum four 16K
ABIS timeslots.
If the EDGE is not supported and the carrier is old, allocate Abis in
accordance with the maximum number of 16K ABIS timeslots supported
by the carrier.
This parameter is also valid when the access mode is IP. The following
is the correspondence relationship:
One 16K ABIS timeslot the maximum bandwidth with the FDR_CS2
coding scheme supported.
Two 16K ABIS timeslots the maximum bandwidth with the FDR_CS4
coding scheme supported.
Four 16K ABIS timeslots the maximum bandwidth with the FDR_MCS9

Description

coding scheme supported.

Managed Object

BSC
1..3
1.One 16K ABIS timeslot is bound at most.
2. Two 16K ABIS timeslots are bound at most.
3. Four 16K ABIS timeslots are bound at most.

Value Range and Step

Step: 1

Unit

None

Default Value

Four 16K ABIS timeslots are bound at most.

Default Value

Four 16K ABIS timeslots are bound, to ensure the adequate access

Configuration Reason

bandwidth.
If the cell does not support EDGE, this value can be set as two 16K ABIS
timeslots bound at most.

Configuration Rule and

The GPRS and EDGE users can be separated completely in the cell.If

Adjustment Suggestion

the cell is configured with the dedicated EDGE only, or channels


preferred, and GPRS together with EDGE not supported, this value can
be set as two 16K ABIS timeslots bound at most.

4-291
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.24 GPRS initial downlink allocation by multislot class 1


(Info1_1_4)
Full Name

GPRS initial downlink allocation by multislot class 1

Abbreviation

Info1_1_4

3GPP Name

None

3GPP Reference

None
This parameter is to indicate whether the initial channel allocation in downlink is based on multislot capability 1 (i.e. uplink 1 downlink 1) or based
on the MS' actual multislot capability specified in downlink assignment.
It is recommended to allocate in accordance with the multislot capability
1 when the channels or ABIS transmission resources are inadequate, to

Description

prevent rapid expansion of channels.

Managed Object

Cell
0: No; 1: Yes
Yes: Allocate in accordance with the multislot capability 1

Value Range and Step

No: Allocate in accordance with the actual multislot capability

Unit

None

Default Value

Yes

4-292
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value
Configuration Reason

The value is 1 by default, to prevent rapid expansion of channels.

Configuration Rule and

If radio resources and ABIS resources are adequate, this value can be

Adjustment Suggestion

set as "No" to reduce the times of resource adjustment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.25 Service UTRAN CCO support (UTRANCCOSupp)


Full Name

Service UTRAN CCO support

Abbreviation

UTRANCCOSupp

3GPP Name

None

3GPP Reference

None
This parameter describes whether the 2G/3G PS cell
reselection/handover priority is supported."Yes" indicates the PS
reselection/handover uses the 2/3G priority control strategy; "No"
indicates the PS reselection/handover does not use the 2/3G priority
control strategy. The priority control strategy, which is dependent upon
BSC and SGSN together, is set through parameter CCOStrategy, as
shown below:
Reselect or handover to 3G preferred Reselect or handover to 2G

Description

preferred reselect or handover to 3G not allowed

4-293
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Reselect or handover to 3G preferred Reselect or handover to 3G


preferred Reselect or handover to 3G preferred reselect or handover to
3G not allowed
Reselect or handover to 2G preferred Reselect or handover to 3G
preferred Reselect or handover to 3G preferred Reselect or handover to
3G not allowed
Reselect or handover to 3G not allowed Reselect or handover to 3G not
allowed Reselect or handover to 3G not allowed Reselect or handover to
3G not allowed
If SGSN has no requirements, reselect or handover to 3G by default
Take the value of SGSN, SGSN without Service UTRAN CCO, Take
the default value of BSC.
If SGSN has no requirements, reselect or handover to 2G by default
If SGSN has no requirements, it is not allowed to reselect or handover
to 3G by default
Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


This parameter is enabled if the 2/3G interworking for GPRS is needed.
Otherwise, it is disabled. This function is related to the function of NCCR
and PS. Currently, it is recommended not to enable this function.

Change Mode

Offline

Related features

ZGO-02-03-004 Inter-system NCCR

Related Parameters

[BSC]PSUTRANCCOSupp

Relationship

After BSCPSUTRANCCOSupp is enabled, this parameter is valid.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

4-294
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

None

4.13.26 Strategy of servic UTRAN CCO (CCOStrategy)


Full Name

Strategy of servic UTRAN CCO

Abbreviation

CCOStrategy

3GPP Name

None

3GPP Reference

None
This parameter indicates the preferential control policy of 2/3G for PS

Description

reselection/handover at the iBSC side.

Managed Object

Cell
0: Handover to 3G prefered
1: Handover to 3G not prefered
2: Handover to 3G not allowed
3: If SGSN has no requirements, reselect or handover to 3G prefered by
default
4: If SGSN has no requirements, reselect or handover to 3G not
prefered by default
5: If SGSN has no requirements, reselect or handover to 3G not allowed

Value Range and Step

by default

Unit

None
If SGSN has no requirements, reselect or handover to 3G not prefered by

Default Value

default.

Default Value
Configuration Reason

The default value is dependant on the general network condition.


When the preferential control strategy of 2/3G for PS selection

Configuration Rule and


Adjustment Suggestion

is enabled, the valiue is dependent upon CN and the operator's


requirement.If you wish PS to reselect the 3G network, select 3G
prefered. If you wish CN to determine the priority on the basis of the
network load, select SGSN prefered.

Change Mode

Offline

Related features

ZGO-02-03-004 Inter-system NCCR

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

4-295
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.27 Enable no data during extended uplink TBF mode


(INFO1_5_0)
Full Name

Enable no data during extended uplink TBF mode

Abbreviation

INFO1_5_0

3GPP Name

EXT_UTBF_NO_DATA

3GPP Reference

3GPP TS 44.060 V7.19.0


This parameter indicates whether it is allowed not to send the Dummy
control block when the uplink TBF is extended. This parameter information is broadcast to the MS in the system message SI13 on BCCH, and in
the GPRS Cell options of the packet system message PSI13 on PACCH.If
this parameter is set as "No", it means to send PACKET UPLINK DUMMY
CONTTROL BLOCK when there is no RLC data block to send on the uplink block allocated by the network. If this parameter is set as "Yes", it
means not to send PACKET UPLINK DUMMY CONTTROL BLOCK when
there is no RLC data block to send on the uplink block allocated by the

Description

network.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

Currently, few MSs are supported. You can set the default value

Configuration Reason

according to the actual network configuration.

Configuration Rule and

If the extended TBF function is enabled, it is recommended to enable

Adjustment Suggestion

the function to save the MS' power.

Change Mode

Offline

Related features

ZGO-04-02-014 Extended uplink TBF mode

4-296
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

[Cell]EXT_UTBF

Relationship

This function should be enabled with EXT_UTBF.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.13.28 Downlink TBF pre-establish support (EarlyDlTBFEstSupp)


Full Name

Downlink TBF pre-establish support

Abbreviation

EarlyDlTBFEstSupp

3GPP Name

None

3GPP Reference

None
The parameter determines whether the cell supports the pre-establish-

Description

ment of downlink TBF.

Managed Object

CELL
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

Not a basic function, disabled by default.

Configuration Rule and

The feature is disabled generally, and enabled in special cases such as

Adjustment Suggestion

to reduce the delay of the first packet.

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

4-297
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 2

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

4.13.29 Downlink Delay time in data TBF Mode (DataTBFDlDelay


Time)
Full Name

Downlink Delay time in data TBF Mode

Abbreviation

DataTBFDlDelayTime

3GPP Name

None
TS 44.060: Radio Link Control/Medium Access Control (RLC/MAC) pro-

3GPP Reference

tocol"

Description

This parameter specifies the downlink delay of the data TBF.

Managed Object

Cell
500..4000

Value Range and Step

Step: 1

Unit

ms

Default Value

2000

Default Value

Downlink delay time in data TBF mode is consistent with the original

Configuration Reason

parameter "Downlink delay time".

Configuration Rule and

It is not recommended to modify the value. Modification can affect the

Adjustment Suggestion

service quality.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

4-298
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID->GPRS Other


Params2

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

4.13.30 Extendable uplink TBF time in data TBF Mode


(DataTBFExtUlTime)
Full Name

Extendable uplink TBF time in data TBF Mode

Abbreviation

DataTBFExtUlTime

3GPP Name

None
TS 44.060: Radio Link Control/Medium Access Control (RLC/MAC) pro-

3GPP Reference

tocol"
This parameter specifies the extendable uplink TBF time in data TBF

Description

Mode.

Managed Object

Cell
0..3000

Value Range and Step

Step: 1

Unit

ms

Default Value

1500

Default Value

The extendable uplink TBF time in data TBF Mode is consistent with the

Configuration Reason

original parameter "Extendable uplink timer".

Configuration Rule and

It is not recommended to modify the value. Modification can affect the

Adjustment Suggestion

service quality.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

4-299
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID->GPRS Other


Params2

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

4.14 GPRS Other Parameters 3


4.14.1 C/I (Sc)
Full Name

C/I

Abbreviation

Sc

3GPP Name

None

3GPP Reference

None
BSC uses MEAN_BEP which is equivalent to C/I to indicate radio
transmission quality, and adjusts block allocation according to the radio
transmission quality. The MEAN_BEP is classified into 7 grades, and
each grade corresponds to a weight. The weight is dynamically added to
the weight calculated from UMTS QoS parameters, as the evidence of
allocating the shared block.
Allocation weight that corresponds to the MEAN_BEP grade is as
follows:
MEAN_BEP grade MEAN_BEP value Allocation weight
0 0..4 -3*Sc
1 5..9 -2*Sc
2 10..13 -Sc
3 14..17 0
4 18..21 Sc
5 22..26 2*Sc

Description

6 27..31 3*Sc

Managed Object

Cell
0 .. 8

Value Range and Step

Step: 1

4-300
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Unit

None

Default Value

Default Value
Configuration Reason

The default value, together with Sa, St, acts on the QoS weight
algorithm. The scheduling algorithm brings a minimal impact on the
weight when the default value is 2.
The resource allocation of the user with great interference should not
be limited any more. Otherwise, the user's speed is too low because of

Configuration Rule and

the available radio resources are inadequate.

Adjustment Suggestion

The BSC does not use the MEAN_BEP to allocate different PDTCH
resources for different non-GBR users, which helps increase users'
throughput under the severe radio environment.

Change Mode

Offline

Related features

ZGO-01-02-002 C/I based Packet Scheduling

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.2 ARP (Sa)


Full Name

ARP

Abbreviation

Sa

3GPP Name

None

3GPP Reference

None

4-301
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The allocation weight for the shared radio block is slightly adjusted
according to the ARP parameter (priority level).
The allocation weight that corresponds to ARP is as follows:
ARP Allocation Weight
1 2*Sa
2 Sa
Description

30

Managed Object

Cell
0 .. 8

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default value, together with Sa, St, acts on the QoS weight
algorithm. The scheduling algorithm brings a minimal impact on the
weight when the default value is 3.
This parameter influences the adjustment of the QoS weight allocated by

Configuration Rule and


Adjustment Suggestion

the radio block. The larger the value is, the more obvious the adjustment
is.For the users with high priority, a certain weight needs to be set for
them, to ensure that more resources are and a better service is available
for them.

Change Mode

Offline

Related features

ZGO-01-02-001 Support ARP in Packet Scheduling

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters 3
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-302
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.14.3 THP (St)


Full Name

THP

Abbreviation

St

3GPP Name

None

3GPP Reference

None
This parameter is an amplification factor that is specially designed for
THP at the BSC side to increase the weight of THP in QoS.
Corresponding to different THP values, the weights that the parameter
THP(St) maps are as follows:
THP Allocation weight
00
1 6+3*THP(St)
2 4+2*THP(St)

Description

3 2+THP(St)

Managed Object

Cell
0 .. 8

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default value, together with Sa, St, acts on the QoS weight
algorithm. The scheduling algorithm brings a minimal impact on the
weight when the default value is 4.
This parameter influences the adjustment of the QoS weight allocated by

Configuration Rule and

the radio block. The larger the value is, the more obvious the adjustment

Adjustment Suggestion

is. This parameter is influenced by the QoS parameter set at the core
network side, so it is recommended to use the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3
4-303

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.4 PS queuing support (PsQueueInd)


Full Name

PS queuing support

Abbreviation

PsQueueInd

3GPP Name

None

3GPP Reference

None
If PFC is suppoted, iBSC allocates radio resources according to users'
subscribed QoS parameter. When the users' subsribed QoS parameter
is unsatisfied (including through preemption), and the QoS parameter
allows queuing, if this parameter is enabled, the iBSC allocates radio
resources to the user according to Best Effort, and make the user
jump into the queue, to wait for the allocation of radio resources. The
queuing time can be obtained through the PFC process; otherwise if this
parameter is disabled, accessing to this service is directly refused.
When this parameter is Yes, you can configure the PsMaxQueueInstNum

Description

parameter.

Managed Object

Cell
1: Yes, No

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


When this switch is enabled, the IBSC allocates radio resources to the

Configuration Rule and

user according to Best Effort, and make the user jump into the queue,

Adjustment Suggestion

to wait for the allocation of radio resources. This function needs to be


supported by the FFC function and is better to be disabled.

Change Mode

Offline
ZGO-01-02-004 Streaming Service Policies
ZGO-01-02-003 Service based QoS

Related features

ZGB-01-02-001 Quality of Service (QoS)

Related Parameters

[BSC]PFCSupport
[Cell]PsMaxQueueInstNum

4-304
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Relationship

This parameter is valid until the FFC function is supported by the system.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.5 Max PS Queue Count (PsMaxQueueInstNum)


Full Name

Max PS Queue Count

Abbreviation

PsMaxQueueInstNum

3GPP Name

None

3GPP Reference

None
This parameter indicates the number of services allowed to queue up in
the cell. When the number of users in a queue reaches this value, there-

Description

after the service that needs to join the queue will be refused to access.

Managed Object

Cell
1 .. 16

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Setting of the default value is in accordance with this parameter's

Configuration Reason

function and usage, and the user rate.

Configuration Rule and

rate cannot be ensured with too many users in a queue because the

Adjustment Suggestion

radio resource allocation of the user is in accordance with Best Effort.

This function cannot be fulfilled with few users in a queue, while the user

Therefore, it is recommended to take the intermediate value.


Change Mode

Offline
ZGO-01-02-004 Streaming Service Policies
ZGO-01-02-003 Service based QoS

Related features

ZGB-01-02-001 Quality of Service (QoS)


4-305

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

Relationship

[Cell]PsQueueInd
When the PsQueueInd parameter is Yes, you can configure this
parameter.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.6 PS preemption support (PsPreemptionInd)


Full Name

PS preemption support

Abbreviation

PsPreemptionInd

3GPP Name

None

3GPP Reference

None
When PFC is supported, iBSC allocates radio resources according to
user's subscribed QoS parameter. When the user's subscribed QoS parameter can't be satisfied and the user's QoS parameter allows preemption, if this switch is enabled, the user can preempt the radio resource with

Description

low priority.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


When this switch is enabled, the user can preempt the radio resource

Configuration Rule and

with low priority services. This function is valid until the PFC function is

Adjustment Suggestion

supported. You can decide whether to enable this function according


to the on-site requirement.

4-306
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Change Mode

Offline
ZGO-01-02-004 Streaming Service Policies
ZGO-01-02-003 Service based QoS

Related features

ZGB-01-02-001 Quality of Service (QoS)

Related Parameters

[BSC]PFCSupport

Relationship

This parameter is valid until the FFC function is supported by the system.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.7 3G NACC support (Support3GCCN)


Full Name

3G NACC support

Abbreviation

Support3GCCN

3GPP Name

3G_CCN_ACTIVE

3GPP Reference

3GPP TS 44.060 V8.3.0


The network uses the parameter 3G_CCN_ACTIVE broadcast in the
SI2quater message on the BCCH to indicate the cell whether CCN is
enabled for cell reselection towards 3G cells.
If the 3G_CCN_ACTIVE parameter does not exist or CCN is indicated
to be disabled, the MS does not follow the CCN procedures when
it performs reselection towards 3G cells.If the network uses the
G_CCN_ACTIVE parameter to indicate the cell to enable CCN, the
MS follows the CCN procedures when it performs reselection towards
3G cells. The 3G_CCN_ACTIVE parameter information can also be
sent to a certain MS through the PACKET MEASUREMENT ORDER
or PACKET CELL CHANGE ORDER message. The PACKET CELL

Description

CHANGE ORDER message is applicable to the target cell.

Managed Object

Cell

4-307
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


This function can be enabled according to the inter-operation of 2/3G.
If you prefer the MS to perform reselection towards 3G cells when it
enters CCN mode, use this function.

Change Mode

Offline

Related features

ZGO-02-02-011 Inter-BSC NACC

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.8 PS preempt CS support (PSPrmpCSSupport)


Full Name

PS preempt CS support

Abbreviation

PSPrmpCSSupport

3GPP Name

None

3GPP Reference

None
This parameter indicates when dynamic channel with preferred PDCH is
occupied by CS, to determine whether the channel can be preempted
by PS service.
If this parameter is "Yes", the PS service can preempt the dynamic
channel with preferred PDCH when the PS service fails to apply for

Description

channels because the radio resources are inadequate.

4-308
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value

This is a functional switch which supports PS in preempting CS and is

Configuration Reason

disabled by default.

Configuration Rule and

If radio resources are limited, this switch can be enabled to ensure the

Adjustment Suggestion

number of necessary PS channels.

Change Mode

Offline

Related features

None

Related Parameters

[Ts]PDCHPrecedence
PSservice can only the channel configured with the PDCHPrecedence

Relationship

attribute, so this parameter is valid only when the channel is configured


with this attribute.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.9 Maximal resource for POC service (POCSrcThs)


Full Name

Maximal resource for POC service

Abbreviation

POCSrcThs

3GPP Name

None

3GPP Reference

None

4-309
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

PoC - Push to Talk over Cellular PoC is a Push to talk service that uses
VoIP technology and is based on the mobile network.
PoC service defines a half-duplex VoIP system applicable to mobile
devices, and makes use of the packet switching capability of radio data
network.
This new function influences the conventional PS channel allocation
policy as the following:
1. Once there are POC users on the PS channel, it is not allowed to
allocate new ordinary PS services to the PS channel until all POC users
on the channel are released.
2. It is better to allocate all the POC users on the channel of the existing
POC users till channel congestion occurs.
This parameter indicates the percentage of current available PS
Description

channels occupied by the POC service.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

50

Default Value

This is a PoCspecial functional switch, which is not enabled at the

Configuration Reason

suggestion.

Configuration Rule and

This is a PoCspecial functional switch, which is not enabled at the

Adjustment Suggestion

suggestion.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-310
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.14.10 Enable uplink interference decision in NC2 (INFO1_5_1)


Full Name

Enable uplink interference decision in NC2

Abbreviation

INFO1_5_1

3GPP Name

None

3GPP Reference

None

Description

This parameter determines whether to enable uplink interference decision


in NC2.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.11 Enable downlink interference decision in NC2 (INFO1_5_2)


Full Name

Enable downlink interference decision in NC2

4-311
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

INFO1_5_2

3GPP Name

None

3GPP Reference

None

Description

This parameter determines whether to enable downlink interference decision


in NC2.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.12 P of uplink interference decision in NC2 (INFO1_5_3)


Full Name

P of uplink interference decision in NC2 (INFO1_5_3)

Abbreviation

INFO1_5_3

3GPP Name

None

3GPP Reference

None
4-312

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters


This parameter defines the P value of uplink interference decision in NC2.
The P value of uplink interference decision in NC2 should be not more than
Description

the N value of uplink interference decision in NC2.

Managed Object

Cell

Value Range and Step

1 ~ 31

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.13 N of uplink interference decision in NC2 (INFO1_5_8)


Full Name

N of uplink interference decision in NC2

Abbreviation

INFO1_5_8

3GPP Name

None

3GPP Reference

None
This parameter defines the N value of uplink interference decision in NC2.

Description

The P value of uplink interference decision in NC2 should be not more than
the N value of uplink interference decision in NC2.

4-313
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell

Value Range and Step

1 ~ 31

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters 3
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.14 P of downlink interference decision in NC2 (INFO1_5_13)


Full Name

P of downlink interference decision in NC2

Abbreviation

INFO1_5_13

3GPP Name

None

3GPP Reference

None
This parameter defines the P value of downlink interference decision in

Description

NC2. The value should be not more than the N value of uplink interference
decision in NC2.

Managed Object

Cell

Value Range and Step

1 ~ 31
4-314

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.15 N of downlink interference decision in NC2 (INFO1_5_18)


Full Name

N of downlink interference decision in NC2

Abbreviation

INFO1_5_18

3GPP Name

None

3GPP Reference

None

Description

The P value of downlink interference decision in NC2 should be not more

This parameter defines the N value of downlink interference decision in NC2.


than the N value of uplink interference decision in NC2.
Managed Object

Cell

Value Range and Step

1 ~ 31

Unit

None

Default Value

3
4-315

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.16 Quality offset of uplink interference in NC2 (INFO1_5_23)


Full Name

Quality offset of uplink interference in NC2

Abbreviation

INFO1_5_23

3GPP Name

None

3GPP Reference

None

Description

This parameter defines the quality offset of uplink interference in NC2.

Managed Object

Cell

Value Range and Step

0 ~ 16

Unit

None

Default Value

Default Value
Configuration Reason

None

4-316
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.17 Signal offset of uplink interference in NC2 (INFO1_6_0)


Full Name

Signal offset of uplink interference in NC2

Abbreviation

INFO1_6_0

3GPP Name

None

3GPP Reference

None

Description

This parameter defines the signal level offset of uplink interference in NC2.

Managed Object

Cell

Value Range and Step

0 ~ 20

Unit

None

Default Value

10

Default Value
Configuration Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline
4-317

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.18 Quality offset of downlink interference in NC2 (INFO1_6_5)


Full Name

Quality offset of downlink interference in NC2

Abbreviation

INFO1_6_5

3GPP Name

None

3GPP Reference

None

Description

This parameter defines the quality offset of downlink interference in NC2.

Managed Object

Cell

Value Range and Step

0 ~ 16

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

4-318
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.19 Signal offset of downlink interference in NC2 (INFO1_6_10)


Full Name

Signal offset of downlink interference in NC2

Abbreviation

INFO1_6_10

3GPP Name

None

3GPP Reference

None

Description

This parameter defines the signal level offset of downlink interference in


NC2.

Managed Object

Cell

Value Range and Step

0 ~ 20

Unit

None

Default Value

10

Default Value
Configuration Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

0
4-319

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.20 Num of samples that calculates average of uplink signal


level in NC2 (INFO1_6_15)
Full Name

Num of samples that calculates average of uplink signal level in NC2

Abbreviation

INFO1_6_15

3GPP Name

None

3GPP Reference

None

Description

This parameter defines the number of samples that calculate average of


uplink signal level in NC2.

Managed Object

Cell

Value Range and Step

1 ~ 31

Unit

None

Default Value

12

Default Value
Configuration Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

4-320
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.21 Num of samples that calculates average of downlink signal


level in NC2 (INFO1_6_20)
Full Name

Num of samples that calculates average of downlink signal level in NC2

Abbreviation

INFO1_6_20

3GPP Name

None

3GPP Reference

None

Description

Managed Object

This parameter defines the number of samples that calculate average of


downlink signal level in NC2.
Cell

Value Range and Step

1 ~ 31

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

4-321
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.22 Num of samples that calculates average of uplink quality


level in NC2 (INFO1_6_25)
Full Name

Num of samples that calculates average of uplink quality level in NC2

Abbreviation

INFO1_6_25

3GPP Name

None

3GPP Reference

None

Description

This parameter defines the number of samples that calculate the average of
uplink quality level in NC2.

Managed Object

Cell

Value Range and Step

1 ~ 31

Unit

None

Default Value

12

Default Value
Configuration Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

4-322
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.23 Num of samples that calculates average of downlink quality


level in NC2 (INFO1_7_0)
Full Name

Num of samples that calculates average of downlink quality level in NC2

Abbreviation

INFO1_7_0

3GPP Name

None

3GPP Reference

None

Description

This parameter defines the number of samples that calculate the average of
downlink quality level in NC2.

Managed Object

Cell

Value Range and Step

1 ~ 31

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

4-323
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.24 NC2 Distance Windows (NC2DistanceWindow)


Full Name

NC2 Distance Windows

Abbreviation

NC2DistanceWindow

3GPP Name

None

3GPP Reference

None

Description

NC2 Distance Windows

Managed Object

CELL

Value Range and Step

1..20

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> GPRS Other


Params3

4-324
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Version

iBSCV6.20.713c

Parameter Modifying
Detail

NEW

4.14.25 Transform from uplink delay to extend (Info1_1_16)


Full Name

Transform from uplink delay to extend

Abbreviation

Info1_1_16

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the instance can be transformed from
the delay status to the extended uplink status.
The transformation details are: If the MS is judged as supporting
extended uplink status, stop the delay timer and start uplink block
allocation to enter the extended uplink status.

Description

Since the version V6.20.200, this parameter is supported.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


When this switch is enabled, The MS, which uses one-phase access,

Configuration Rule and


Adjustment Suggestion

judges whether the extended uplink status is supported according to


the MS' multi-timeslot capability upon receiving downlink data. If it is
supported, transform the delay status to the extended uplink status, to
keep the uplink TBF from reestablishment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

4-325
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.26 Max Num of resend packet assignment (Info1_1_8)


Full Name

Max Num of resend packet assignment

Abbreviation

Info1_1_8

3GPP Name

None

3GPP Reference

None
When the number of times of resending assignment messages exceeds
the maximum number of times of resending packet assignment
messages specified at the background, if the response message sent
by the MS is not received, send the TBF Release message to notify
the MS of releasing TBF.
During the service processing process, if CTRL_ACK is lost, judge
the assignment type that MAC is waiting for. If the assignment type
is consistent with that MAC is waiting for, the number of resending
assignment messages increments and the uplink/downlink assignment
message is resent. If the assignment type exceeds the maximum
number of resending assignment messages but the assignment
acknowledgement message from MS is still not received, the TBF
Release message is issued from network and TBF is released. If
the assignment type is inconsistent with that MAC is waiting for, the
assignment timer is cleared and the assignment message will not be
resent.

Description

Since the version V6.20.21, this parameter is supported.

Managed Object

Cell
0 .. 10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

4-326
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Configuration Rule and


Adjustment Suggestion

When this function is enabled, if the assignment message is lost, it will


be re-sent to keep its service from abnormal due to poor radio quality
or other abnormal cases.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.27 Resource adjust for CS preempt (Info1_1_17)


Full Name

Resource adjust for CS preempt

Abbreviation

Info1_1_17

3GPP Name

None

3GPP Reference

None
When events, such as CS preemption, that the PS channel should
be released occur, if the control plane judges that the timeslot to
be released is not important or unique after receiving the dynamic
channel conversion message, then the control plane initiates resource
adjustment and sends the resource assignment message to the user
plane. The user plane then sends packet uplink/downlink assignment
messages or timeslot reallocation messages to the MS.

Description

Since the version V6.20.21, this parameter is supported.

Managed Object

Cell
Yes/No

Value Range and Step

0: No; 1: Yes

Unit

None
4-327

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


When this function is enabled, if the PDCH channel is preempted

Configuration Rule and

by CS during the service processing process, the control plane will

Adjustment Suggestion

initiate a resource adjustment process, and the TBF will not be released
abnormally because the resources are preempted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.28 Subcell selection of PS channel allocation (PSALLOCSC_0)


Full Name

Subcell selection of PS channel allocation

Abbreviation

PSALLOCSC_0

3GPP Name

None

3GPP Reference

None

4-328
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

After the subcell is configured, this parameter is used to control the


subcell selection strategy. The strategy includes the first subcell
preferred, the second subcell preferred, and the first subcell only.
This parameter influences the strategy for the control plane to apply
for channels with the database. The control plane, together with this
parameter configuration, decides the strategy.
Configuration instructions:
The first subcell only: The parameter strategy transmitted from the
control plane to the database can only be the first subcell, and this
parameter is configured for the current network only when the first
subcell supports PS service.
The first subcell preferred: If the user can stay at the first subcell or the
second subcell (determined by the level and TA value), the allocation
strategy transmitted to the database is the first subcell preferred.
The second subcell preferred: If the user can stay at the first subcell or
the second subcell (determined by the level and TA value), the allocation
strategy transmitted to the database is the second subcell preferred.
The principle for the database to allocate these three parameters is
as follows:
The first subcell only: The PS service is allocated on the channel of
the first subcell only.
The first subcell preferred: The quota of PFC users cannot be satisfied
or the available channels in the first subcell are inadequate. Otherwise,
the PS service is allocated to the first subcell.
.
The second subcell preferred: The quota of PFC users cannot be
satisfied or the available channels in the first subcell are inadequate.
Otherwise, the PS service is allocated to the second subcell.
Description

Managed Object

Cell
0..2
0: The first subcell preferred;
: The second subcell preferred;
2: The second subcell only;

Value Range and Step

Step: 1

Unit

None

Default Value

The first subcell is preferred.

Default Value

The first subcell aborbs PS traffic by default, so PS channels are

Configuration Reason

preferentially allocated in the first subcell.

4-329
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If the PS channels that can be used are configured only for the first
Configuration Rule and
Adjustment Suggestion

subcell, this parameter can be adjusted as "the first subcell only".


If congestion occurs to the PS service in the first subcell on site, and
the PS channels in the second subcell are idle, this parameter can be
adjusted as " the second subcell preferred".

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.29 RXLEV threshold in subcell 1 (PSALLOCSC_1)


Full Name

RXLEV threshold in subcell 1

Abbreviation

PSALLOCSC_1

3GPP Name

None

3GPP Reference

None
After the subcell is configured, this parameter is used to control the level
threshold for selecting the first subcell.
If the level of the second subcell is lower PSALLOCSC_1, it is necessary
to reselect the first subcell.
If the channel allocation strategy configured by the background is the
second subcell preferred, apply for reselecting the channels with the first
subcell preferred, with the database.

Description

4-330
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

If the channel allocation strategy configured by the background is the


first subcell preferred, apply for reselecting the channels with the first
subcell preferred, with the database.
Managed Object

Cell
0 .. 63
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
2: -110 dBm .. -109 dBm;
......
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

20

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is dependent upon the actual request on site.


The value can be adjusted in accordance with the actual on-site
condition. If the PS traffic in the first subcell is considered as too much,
increase the value appropriately.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]PSALLOCSC_0

Relationship

This parameter is valid only when the parameter PSALLOCSC_0 is


configured as the second subcell preferred or the first subcell preferred.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-331
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.14.30 RXLEV threshold in subcell 2 (PSALLOCSC_2)


Full Name

RXLEV threshold in subcell 2

Abbreviation

PSALLOCSC_2

3GPP Name

None

3GPP Reference

None
After the subcell is configured, this parameter is used to control the level
threshold for selecting the second subcell.
If the level of the first subcell is lower than PSALLOCSC_1, it is
necessary to reselect the subcell.
If the channel allocation strategy configured by the background is the
second subcell preferred, apply for reselecting the channels with the
second subcell preferred, with the database.

If the channel allocation strategy configured by the background is the


first subcell preferred, apply for reselecting the channels with the first

Description

subcell preferred, with the database.

Managed Object

Cell
0 .. 63
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
2: -109 dBm ~ -108 dBm;
......
62: -49 dBm ~ -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

40

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is dependent upon the actual request on site.


The value can be adjusted in accordance with the actual on-site
condition. If the PS traffic in the second subcell is considered as too
much, increase the value appropriately.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]PSALLOCSC_0

Relationship
Related Interfaces

This parameter is valid only when the parameter PSALLOCSC_0 is


configured as the second subcell preferred or the first subcell preferred.
Um

4-332
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.31 Multislot allocation of extended range cell support


(Info1_7_13)
Full Name

Multislot allocation of extended range cell support

Abbreviation

Info1_7_13

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the extended cell supports multiple
timeslots allocation. The extended cell can allocate 1..3 channels in

Description

accordance with the nultiple-timeslot capability of the MS.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is not enabled at the suggestion.

Configuration Rule and


Adjustment Suggestion

This is a special functional switch, which is not enabled at the suggestion.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

4-333
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.32 Support resource optimizing by service (SuppResOpBySe


rvice)
Full Name

Support resource optimizing by service

Abbreviation

SuppResOpByService

3GPP Name

None

3GPP Reference

None
This parameter determines whether to support the cell switch for resource

Description

control based on the classification of subscriber services.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Enable this switch as required.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
4-334

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.14.33 RxLev P Value (RxLevP)


Full Name

RxLev P Value

Abbreviation

RxLevP

3GPP Name

None

3GPP Reference

None
This parameter determines the P value of the level after subcell handover
judgment. If P out of N signal strengths meet this threshold, handover is

Description

required.

Managed Object

Cell

Value Range and Step

0..31

Unit

None

Default Value

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.

Configuration Rule and


Adjustment Suggestion

This value of this parameter affects the sensitivity of subcell judgment.


The larger the value of this parameter, the lower the sensitivity. Usually,
it is recommended that the value of this parameter be not modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-335
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying

Its previous name is byPbcchblockNum. It is BIT12-BIT16 of INFO 2 in

Detail

the previous PSBTS table.

4.14.34 RxLev N Value (RxLevN)


Full Name

RxLev N Value

Abbreviation

RxLevN

3GPP Name

None

3GPP Reference

None
This parameter determines the N value of the level after subcell handover
judgment. If P out of N signal strengths meet this threshold, handover is

Description

required.

Managed Object

Cell

Value Range and Step

0..31

Unit

None

Default Value

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.

Configuration Rule and


Adjustment Suggestion

This value of this parameter affects the sensitivity of subcell judgment.


The larger the value of this parameter, the lower the sensitivity. Usually,
it is recommended that the value of this parameter be not modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-336
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

It is BIT17-BIT21 of INFO 2 in the previous PSBTS table.

4.14.35 TA P Value (TaP)


Full Name

TA P Value

Abbreviation

TaP

3GPP Name

None

3GPP Reference

None
This parameter determines the P value of the TA after subcell handover
judgment. If P out of N TA values meet this threshold, handover is re-

Description

quired.

Managed Object

Cell

Value Range and Step

0..31

Unit

None

Default Value

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.

Configuration Rule and


Adjustment Suggestion

This value of this parameter affects the sensitivity of subcell judgment.


The larger the value of this parameter, the lower the sensitivity. Usually,
it is recommended that the value of this parameter be not modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-337
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

It is BIT22-BIT26 of INFO 2 in the previous PSBTS table.

4.14.36 TA N Value (TaN)


Full Name

TA N Value

Abbreviation

TaN

3GPP Name

None

3GPP Reference

None
This parameter determines the N value of the TA after subcell handover
judgment. If P out of N TA values meet this threshold, handover is re-

Description

quired.

Managed Object

Cell

Value Range and Step

0..31

Unit

None

Default Value

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.

Configuration Rule and


Adjustment Suggestion

This value of this parameter affects the sensitivity of subcell judgment.


The larger the value of this parameter, the lower the sensitivity. Usually,
it is recommended that the value of this parameter be not modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-338
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

It is BIT27-BIT31 of INFO 2 in the previous PSBTS table.

4.14.37 SubCell1 PS Busy Threshold (SubCell1PsChanThs)


Full Name

SubCell1 PS Busy Threshold

Abbreviation

SubCell1PsChanThs

3GPP Name

None

3GPP Reference

None
This parameter determines the busyness threshold of the first subcell.
When the channel busyness of the first subcell exceeds this threshold,

Description

the system trigger reselection to the second subcell.

Managed Object

Cell

Value Range and Step

0..100

Unit

Default Value

80

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.

Configuration Rule and


Adjustment Suggestion

It is required to configure this parameter according to the actual network


operation. To hope that the load in the first subcell is not excessively
high, it is required to properly lower the busyness threshold.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-339
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

It is BIT0-BIT7 of INFO 3 in the previous PSBTS table.

4.14.38 SubCell2 PS Busy Threshold (SubCell2PsChanThs)


Full Name

SubCell2 PS Busy Threshold

Abbreviation

SubCell2PsChanThs

3GPP Name

None

3GPP Reference

None
This parameter determines the busyness threshold of the second subcell.
When the channel busyness of the second subcell exceeds this threshold,

Description

the system trigger reselection to the first subcell.

Managed Object

Cell

Value Range and Step

0..100

Unit

Default Value

80

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.

Configuration Rule and


Adjustment Suggestion

It is required to configure this parameter according to the actual network


operation. To hope that the load in the second subcell is not excessively
high, it is required to properly lower the busyness threshold.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-340
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

It is BIT8-BIT15 of INFO 3 in the previous PSBTS table.

4.14.39 TA threshold for PS channel allocate in subcell1


(TaLevelThs1)
Full Name

TA threshold for PS channel allocate in subcell1

Abbreviation

TaLevelThs1

3GPP Name

None

3GPP Reference

None
This parameter determines the minimum TA threshold when the channel
is allocated on the first subcell. When the TA value is larger than this

Description

threshold, the channel will be allocated to the first subcell.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

Default Value

It is required to configure this parameter according to the general subcell

Configuration Reason

coverage.
The larger the value of this parameter, the harder the operation of

Configuration Rule and

allocating the channel to the first subcell. When the coverage of the

Adjustment Suggestion

second subcell is good, it is required to properly increase this value.


Otherwise, decrease this value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-341
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying

Its previous name is byPagchBlockNum. It is BIT0-BIT5 of INFO 2 in

Detail

the previous PSBTS table.

4.14.40 TA threshold for PS channel allocate in subcell2


(TaLevelThs2)
Full Name

TA threshold for PS channel allocate in subcell2

Abbreviation

TaLevelThs2

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum TA threshold when the channel
is allocated on the second subcell. When the TA value is smaller than this

Description

threshold, the channel will be allocated to the second subcell.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

Default Value

It is required to configure this parameter according to the general subcell

Configuration Reason

coverage.
The smaller the value of this parameter, the harder the operation of

Configuration Rule and

allocating the channel to the second subcell. When the coverage of the

Adjustment Suggestion

second subcell is good, it is required to properly increase this value.


Otherwise, decrease this value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-342
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other


Parameters 3

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying

Its previous name is byPrachBlockNum. It is BIT6-BIT11 of INFO 2 in

Detail

the previous PSBTS table.

4.14.41 Resource adjust threshold (ResourceAdjustThs)


Full Name

Resource adjust threshold

Abbreviation

ResourceAdjustThs

3GPP Name

None

3GPP Reference

None
During the processing of PS service, the Ranps instance performs
a handshaking with the Mac instance at a period of 5s. The user
plane judges whether resource adjustment is needed upon receiving a
handshaking request from the Ranps instance. This parameter indicates
the resource adjustment threshold, which is used in a decision algorithm
for determining whether to move group resources from single timeslot
to multiple timeslots.
The following describes the adjustment criteria:
When the sum of uplink and downlink traffic is less than this threshold,
no resource adjustment is needed.
When the uplink traffic is higher than the downlink traffic, perform
resource adjustment based on uplink priority.
When uplink traffic is lower than downlink traffic, and the difference
between downlink and uplink traffic is less than a quarter of the
threshold, perform the resource adjustment based on uplink priority.
In the other cases, perform the resource adjustment based on downlink

Description

priority.

Managed Object

BSC
200..50000

Value Range and Step

Step: 1

Unit

Byte

Default Value

2000

Default Value

The default value is an experimental value for a common radio

Configuration Reason

environment.

4-343
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The larger the parameter value is, the more difficult the sum of uplink
and downlink traffic can reach this threshold, and therefore the less
likely the resource adjustment will be performed. Even the sum of uplink
Configuration Rule and

and downlink traffic reaches the threshold, the difference between uplink

Adjustment Suggestion

and downlink traffic is more difficult to reach a quarter of the threshold,


which more likely results in resource adjustment based on uplink priority.
This parameter can be appropriately reset on field to adjust the initiation
speed and direction priority of resource adjustment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

GB

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Other

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters 3
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.14.42 Info1_2
Full Name

Info1_2

Abbreviation

Info1_2

3GPP Name

None

3GPP Reference

None

Description

This parameter is currently not used.

Managed Object

Cell

Value Range and Step

0..4294967295

Unit

None

Default Value

4-344
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value
Configuration Reason

This parameter is currently not used.

Configuration Rule and


Adjustment Suggestion

This parameter is currently not used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID->GPRS Other


Params3

Parameter Modifying
Version

iBSCV6.20.711c

Parameter Modifying
Detail

New

4.14.43 Info1_3
Full Name

Info1_3

Abbreviation

Info1_3

3GPP Name

None

3GPP Reference

None

Description

This parameter is currently not used.

Managed Object

Cell

Value Range and Step

0..4294967295

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is currently not used.

Configuration Rule and


Adjustment Suggestion

This parameter is currently not used.

Change Mode

Offline
4-345

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID->GPRS Other


Params3

Parameter Modifying
Version

iBSCV6.20.711c

Parameter Modifying
Detail

New

4.14.44 Is Dual-Frequency NC2 Support (DualFreqNC2Sup)


Full Name

Is Dual-Frequency NC2 Support

Abbreviation

DualFreqNC2Sup

3GPP Name

None

3GPP Reference

None

Description

Is Dual-Frequency NC2 Support

Managed Object

CELL

Value Range and Step

0: No 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None
4-346

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> GPRS Other


Params3

Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

4.14.45 Dual-Frequency NC2 Parameter N (DualFreqNC2N)


Full Name

Dual-Frequency NC2 Parameter N

Abbreviation

DualFreqNC2N

3GPP Name

None

3GPP Reference

None
Dual-frequency network NC2 parameter N. This parameter is used in the
re-selection algorithm based on interference, quality, level, better neigh-

Description

bor cell, and TA.

Managed Object

CELL

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

4-347
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> GPRS Other


Params3

Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

4.14.46 Dual-Frequency NC2 Parameter P (DualFreqNC2P)


Full Name

Dual-Frequency NC2 Parameter P

Abbreviation

DualFreqNC2P

3GPP Name

None

3GPP Reference

None
Dual-frequency network NC2 parameter P. This parameter is used in the
re-selection algorithm based on interference, quality, level, better neigh-

Description

bor cell, and TA.

Managed Object

CELL

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

4-348
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> GPRS Other


Params3

Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

4.14.47 Dual-Frequency NC2 TA Threshold (DualFreqNC2TAThr)


Full Name

Dual-Frequency NC2 TA Threshold

Abbreviation

DualFreqNC2TAThr

3GPP Name

None

3GPP Reference

None
This parameter specifies the TA decision threshold for the dual-frequency
network NC2. The parameter is used in the re-selection algorithm based
on the TA value. Of the DualFreqNC2N count of TA values, if the DualFreqNC2P count of TA values are greater than or equal to the value of

Description

this parameter, the TA-based re-selection is performed.

Managed Object

CELL

Value Range and Step

0..63

Unit

None

Default Value

63

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

4-349
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> GPRS Other


Params3

Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

4.14.48 Dual-Frequency NC2 load Threshold (DualCellPsChanThr)


Full Name

Dual-Frequency NC2 load Threshold

Abbreviation

DualCellPsChanThr

3GPP Name

None

3GPP Reference

None
This parameter specifies the load threshold for a dual-frequency NC2 cell.
The parameter is used in a dual-frequency NC2 based on load. When
the serving cell load exceeds this threshold, and the load of the dual-frequency neighbor cell is less than this threshold, a load-based re-selection

Description

is initiated.

Managed Object

CELL

Value Range and Step

0..100

Unit

Default Value

80

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

4-350
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> GPRS Other


Params3

Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

4.14.49 NC2 UL RxLevel Threshold (ULRxLevThr)


Full Name

NC2 UL RxLevel Threshold

Abbreviation

ULRxLevThr

3GPP Name

None

3GPP Reference

None
This parameter specifies the level decision threshold in the NC2 uplink.
The parameter is used for the re-selection algorithm based on the uplink
level. Of the DualFreqNC2N count of average uplink level values, if the
DualFreqNC2P count of level values are less than or equal to the value

Description

of this parameter, a re-selection based on uplink level is performed.

Managed Object

CELL

Value Range and Step

0..63

Unit

None

Default Value

20

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

4-351
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> GPRS Other


Params3

Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

4.14.50 NC2 DL RxLevel Threshold (DLRxLevThr)


Full Name

NC2 DL RxLevel Threshold

Abbreviation

DLRxLevThr

3GPP Name

None

3GPP Reference

None
This parameter specifies the level decision threshold in the NC2 downlink. The parameter is used for the re-selection algorithm based on the
downlink level. Of the DualFreqNC2N count of average downlink level
values, if the DualFreqNC2P count of level values are less than or equal
to the value of this parameter, a re-selection based on downlink level is

Description

performed.

Managed Object

CELL

Value Range and Step

0..63

Unit

None

Default Value

20

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
4-352

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> GPRS Other


Params3

Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

4.14.51 NC2 UL RxQual Threshold (ULRxQualThr)


Full Name

NC2 UL RxQual Threshold

Abbreviation

ULRxQualThr

3GPP Name

None

3GPP Reference

None
This parameter specifies the quality decision threshold in the NC2 uplink.
The parameter is used for the re-selection algorithm based on the uplink quality. Of the DualFreqNC2N count of average uplink BERs, if the
DualFreqNC2P count of BERs are less than or equal to the value of this

Description

parameter, a re-selection based on uplink quality is performed.

Managed Object

CELL

Value Range and Step

0..7

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

4-353
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> GPRS Other


Params3

Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

4.14.52 NC2 DL RxQual Threshold (DLRxQualThr)


Full Name

NC2 DL RxQual Threshold

Abbreviation

DLRxQualThr

3GPP Name

None

3GPP Reference

None
This parameter specifies the quality decision threshold in the NC2 downlink. The parameter is used for the re-selection algorithm based on the
downlink quality. Of the DualFreqNC2N count of average downlink BERs,
if the DualFreqNC2P count of BERs are less than or equal to the value of

Description

this parameter, a re-selection based on downlink quality is performed.

Managed Object

CELL

Value Range and Step

0..7

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

4-354
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> GPRS Other


Params3

Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

4.14.53 avoid Ping-Pang cell reselection Timer (TPingPang)


Full Name

avoid Ping-Pang cell reselection Timer

Abbreviation

TPingPang

3GPP Name

None

3GPP Reference

None
This parameter is the timer for avoiding Ping-Pong re-selection in the
NC2. After an MS re-selects a particular cell, the MS is forbidden to re-se-

Description

lects the source cell before the timer times out.

Managed Object

CELL

Value Range and Step

0..65535

Unit

Second

Default Value

100

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> GPRS Other


Params3
4-355

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

4.14.54 NC2 Reselection hysteresis Threshold (NC2ResHys)


Full Name

NC2 Reselection hysteresis Threshold

Abbreviation

NC2ResHys

3GPP Name

None

3GPP Reference

None
This parameter specifies the NC2 re-selection hysteresis level. The parameter is used for the re-selection based on the better neighbor cell. If
the serving cell downlink level is less than "NC2 reselection DL RxLevel
Threshold" (NC2ResThr) and a better neighbor cell is detected (the C2
value difference between the neighbor cell and serving cell is greater than
the value of this parameter), a re-selection based on the better neighbor

Description

cell is initiated.

Managed Object

CELL

Value Range and Step

0..7

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

4-356
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> GPRS Other


Params3

Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

4.14.55 NC2 reselection DL RxLevel Threshold (NC2ResThr)


Full Name

NC2 reselection DL RxLevel Threshold

Abbreviation

NC2ResThr

3GPP Name

None

3GPP Reference

None
This parameter specifies the downlink level threshold for initiating an NC2
re-selection. The parameter is used for the re-selection based on the better neighbor cell. If the serving cell downlink level is less than "NC2 reselection DL RxLevel Threshold" (NC2ResThr) and a better neighbor cell is
detected (the C2 value difference between the neighbor cell and serving
cell is greater than the value of NC2 reselection hysteresis threshold), a

Description

re-selection based on the better neighbor cell is initiated.

Managed Object

CELL

Value Range and Step

0..63

Unit

None

Default Value

35

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

4-357
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> GPRS Other


Params3

Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

4.15 GPRS Cell Options Parameters


4.15.1 T3168 (T3168)
Full Name

T3168

Abbreviation

T3168

3GPP Name

T3168

3GPP Reference

3GPP TS 44.060 V8.3.0


This parameter is used at the MS side. It belongs to the GPRS Cell
Options IE parameter, and is broadcast to the MS in the SI13 message
on BCCH or in the PSI13 message on PACCH. It indicates the maximum
time length of waiting for the PACKET UPLINK ASSIGNMENT message
after the MS sends the PACKET RESOURCE REQUEST message
(or PACKET DOWNLINK ACK/NACK message with Channel Request
Description IE).
The timer starts after the MS sends the PACKET RESOURCE
REQUEST message, the PACKET DOWNLINK ACK/NACK message
with Channel Request Description IE, or the PACKET CONTROL
ACKNOWLEDGEMENT message requesting for setting up TBF.
The timer stops when the MS receives the PACKET UPLINK
ASSIGNMENT message or the PACKET TIMESLOT RECONFIGURE
message that assigns uplink TBF, or receives the PACKET ACCESS
REJECT message that refuses the uplink TBF.
The times expires when the MS re-initialize the packet access process,
or resend the PACKET RESOURCE REQUEST or PACKET DOWNLINK

Description

ACK/NACK message.

Managed Object

Cell

Value Range and Step

0.5 .. 4.0( the step length is 0.5)

Unit

Default Value

4
4-358

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value

The default value is dependent upon the general radio environment.

Configuration Reason

Usually, it is 1.5 ..2s.


The value influences the uplink TBF establishment time and uplink TBF
establishment successful rate. The smaller the value is, the shorter
the time of waiting for packet uplink assignment. The lower the uplink
TBF establishment successful rate is, the shorter is the average delay
of packet access. The poorer the radio environment is, the lower the
TBF establishment successful rate is. If the value is set as too small,

Configuration Rule and

the request for packet access is more likely to occur, and the probability

Adjustment Suggestion

of the network performing reassignment increases, which lead to a


waste of system resources. The larger the value is, the longer the is
time of waiting for packet uplink assignment. The lower the uplink TBF
establishment successful rate is, the longer is the average delay of
packet access. The poorer the radio environment is, the higher the TBF
establishment successful rate is. You can set the value in accordance
with the network delay requirement and radio quality.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Options
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.15.2 T3192 (T3192)


Full Name

T3192

Abbreviation

T3192

3GPP Name

T3192

4-359
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

3GPP TS 44.060 V8.3.0


This parameter is used at the MS side. It belongs to the GPRS Cell
Options IE parameter, and is broadcast to the MS in the SI13 message
on BCCH or in the PSI13 message on PACCH.During packet downlink
transmission, the MS starts the timer T3192 when it receives all RLC
data blocks. Once the timer T3192 expires, the MS shall release the
resources associated with the TBF (e.g. TFI) and begin to monitor its
paging channel.
The timer starts after the MS sends the PACKET DOWNLINK
ACK/NACK message with Final Ack Indicator=1, or sends the PACKET
CONTROL ACK message as a response to the final data block when
the MS is in RLC unacknowledged mode.
The timer restarts after the MS sends the PACKET DOWNLINK
ACK/NACK message with Final Ack Indicator=1, or sends the PACKET
CONTROL ACK message as a response to the final data block when
the MS is in RLC unacknowledged mode.
If the timer expires when the MS is in packet transmission mode and no
other TBF is in progress, the MS will release resources, stop monitoring
the PDCH channel but begin to monitor the paging channel.
If the MS receives the PACKET DOWNLINK ASSIGNMENT or PACKET

Description

TIMESLOT RECONFIGURE message, the timer T3192 stops.

Managed Object

Cell

Value Range and Step

(500, 1000, 1500, 0, 80, 120, 160, 200)

Unit

ms

Default Value

500

Default Value

The default value is dependent upon the general radio environment.

Configuration Reason

Usually, it is 500 ms.


The higher the value is, the longer is the time of reserving resources
related to TBF (including TFI and timeslots). The invalid resources are
occupied for a long time and congestion is likely to occur when there is
no data transmission.
If the value is set as too small, the MS will quickly release TNF resources.
The time of establishing downlink TBF is longer when new downlink
data is available and the network must initiate a paging procedure or an

Configuration Rule and


Adjustment Suggestion

immediate assignment procedure (if the MS is waiting for assignment).If


the timer T3192 does not expires and new downlink data is available,
the network can send the Packet Downlink Assignment message to
establish a new downlink TNF, to reduce TBF establishment time.
Therefore, this parameter value is dependent upon the value of T3192
which should be set appropriate and large enough by evaluating the
average interval of two downlink data transmissions and considering
the cell situation, such as service load, service mode and sufficient

4-360
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

network resources, so as to reduce the establishment time of new TBF


and improve data transmission rate.
The network has a corresponding timer T3193 of which the value should
be larger than that of T3192.
Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Options

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.15.3 T3142 (Info1_0_2)


Full Name

T3142

Abbreviation

Info1_0_2

3GPP Name

T3142

3GPP Reference

3GPP TS 44.018 V7.2.0


This parameter is used at the MS side. It is notified to the MS in the
wait indication of the IMMEDIATE ASSIGNMENT REJECT or DTM
REJECT message.
This timer starts if the MS receives immediate assignment refusal or
DTM refusal during packet access. The MS in the cell is not allowed to
initiate access request when it receives a wait indication until the timer
expires. The timer does not function if the MS performs cell reselection
due to radio reasons. After the completion of cell reselection, the MS
can attempt to perform packet access in the new cell.
The MS can initiate RR connection in the cell before the timer T3142

Description

expires.

4-361
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell

Value Range and Step

0...255

Unit

Default Value

Default Value
Configuration Reason

The default value is dependent upon the general network busyness.

Configuration Rule and


Adjustment Suggestion

when the RACH resource is inadequate, the value should be lager.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Options
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.15.4 T3172 (Info1_0_3)


Full Name

T3172

Abbreviation

Info1_0_3

3GPP Name

T3172

3GPP Reference

3GPP TS 44.060 V7.2.0

4-362
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter is used at the MS side. It is notified to the MS in


WAIT_INDICATION of the PACKET ACCESS REJECT message.
This timer starts if the MS receives immediate assignment refusal or
DTM refusal during packet access. The MS in the cell is not allowed to
initiate access request when it receives a wait indication until the timer
expires. The timer does not function if the MS performs cell reselection
due to radio reasons. After the completion of cell reselection, the MS
can attempt to perform packet access in the new cell.
The MS can initiate RR connection in the cell before the timer T3142
expires.When the time T3172 is running, the MS shall ignore all received
PACKET PAGING REQUEST messages except it is requested to
establish RR connection.
The MS changes to the idle status if the timer expires before the MS
receives the assignment message.
After this timer expires, the MS does not disable packet access in this
cell, but shall not take channel request as paging response except the
MS receives paging request message.
After the MS receives the PACKET ACCESS REJECT message, the
timer starts.
If the MS receives the PACKET UPLINK ASSIGNMENT message, the
timer stops.
Description

The packet access will not be prohibited after the timer expires.

Managed Object

Cell

Value Range and Step

0...255

Unit

Default Value

Default Value

This parameter is related to the configuration of PBCCH channel, so it is

Configuration Reason

recommended not to use the value.

Configuration Rule and


Adjustment Suggestion

when the RACH resource is inadequate, the value should be lager.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-363
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Options

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.15.5 DRX mode holding timer (DrxTimeMax)


Full Name

DRX mode holding timer

Abbreviation

DrxTimeMax

3GPP Name

DRX_TIMER_MAX

3GPP Reference

3GPP TS 44.060 V8.3.0


This parameter is used at the MS side. It belongs to the GPRS Cell
Options IE parameter, and is broadcast to the MS in the SI13 message
on BCCH or in the PSI13 message on PACCH, indicating the value of
the DRX_TIMER_MAX parameter.In the following two cases, the MS
enters non-DRX mode whose duration is controlled by the parameter
DRX_TIMER_MAX:
1, At the transition from the packet transfer mode to the packet idle
mode, the MS shall enter the non-DRX mode.
2, At the transition from the dual transfer mode to the dedicated mode or
packet idle mode, the MS shall enter the non-DRX mode.
In both cases, the duration of the non-DRX mode is determined by
the minimum value of the DRX_TIMER_MAX and NON_DRX_TIMER
parameters used by the MS. The parameter DRX_TIMER_MAX
is broadcast in the cell system message, while the parameter
NON_DRX_TIMER is negotiated between the MS and CN during GPRS

Description

ATTACH.

Managed Object

Cell

Value Range and Step

(0, 1, 2, 4, 8, 16, 32, 64)

Unit

Default Value

Default Value
Configuration Reason

The default value of BS_PA_MFRMS is 5, and the paging period is


1.18 s which is smaller than the default value 2 s, so TBF can be fast
established within 2 s.

4-364
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

In non-DRX mode, TBF is established faster than it established in DRX


mode, because the Immediate Assignment message is sent much
faster (40 ms) on all PCH and AGCH channels than the message
sent in DRX mode.In DRX mode, the MS can only monitor the paging
message on the paging group to which the MS belongs, and then
receives the Immediate Assignment message on all paging blocks and
Configuration Rule and
Adjustment Suggestion

AGCH reserved blocks. The duration of receiving paging messages is


long. The average duration is half the period of paging multiframe.When
BS_PA_MFRMS is 2, the duration is about 235 ms.
In non-DRX mode, MS consumes more power. Therefore, when
DRX_Timer_Max is large, TBF establishment time can be reduced, but
the power consumption of MS increases. When the value is small, the
power of MS is saved, but the signalling load of the system increases
and data transmission delay increases because paging process is added
in DRX mode.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Options
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.15.6 MAX blocks transmittion in each TS (BsCvMax)


Full Name

MAX blocks transmittion in each TS

Abbreviation

BsCvMax

3GPP Name

BS_CV_MAX

3GPP Reference

3GPP TS 44.060 V8.3.0

4-365
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is used at the MS side and belongs to the GPRS Cell
Options IE. It is broadcast to the MS if the PBCCH channel does not
exist. This parameter indicates the maximum value of countdown (the
initial value of countdown), and is used by the MS to calculate the
countdown value (CV).
The MS shall send the countdown value (CV) in each uplink RLC data
block to notify the network about the absolute serial number of RLC data
blocks which will be sent in the uplink TBF. The CV shall be calculated
as follows:
Where,
TBC =total number of RLC data blocks to be transmitted in the TBF.
BSN' = absolute sequence number of the RLC data block, with the
range 0 ..(TBC - 1).
NTS = number of timeslots assigned to the uplink TBF, with the range 1
to 8.
K = 2 when commanded MCS is MCS-7, MCS-8 or MCS-9, otherwise
K=1.
The value of the function round() is the smallest integer in the bracket.
The division operation result is a non-integer and is zero only for (TBC
- BSN' - 1) = 0.
This parameter also determines the duration of the timer T3200 used by
the MS in non-DRX mode:
T3200=4 *BS_CV_MAX represents the duration;
This parameter determines the value of the parameter N3104max used
by the MS:
Description

N3104_MAX = 3 * (BS_CV_MAX + 3) * NTS

Managed Object

Cell

Value Range and Step

0...15

Unit

None

Default Value

15

Default Value
Configuration Reason

This parameter determines T3200 and N3104MAX at the MS side. It is


better to set the default value as large in consideration of the abnormal
tolerability at the MS side.

4-366
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

If the network does not enable the extended uplink function or the
MS does not support GERA package 1, the MS does not support the
extended uplink function. When the MS enters the countdown process,
all the new uplink LLC data should be sent in one TBF, and the initial
Configuration Rule and
Adjustment Suggestion

value of the countdown number should not be too large in accordance


with the network performance. In addition, in the current network,
some MSs do not support the maximum value 15. Therefore, this
parameter value can be reduced appropriately.If the network enables
the extended uplink function and the MS supports GERA package 1, it
is recommended to set the value as maximum if no negative influence
occurs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Options

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.15.7 Packet control acknowledgement type (CtraCKType)


Full Name

Packet control acknowledgement type

Abbreviation

CtraCKType

3GPP Name

CONTROL_ACK_TYPE

3GPP Reference

3GPP TS 44.060 V5.19.0

4-367
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is used at the MS side. This parameter is used at the MS


side and belongs to the GPRS Cell Options IE. It is broadcast to the MS
in the SI13 message if the PBCCH channel does not exist. This parameter defines the method which is used by the MS to send the PACKET
Description

CONTROL ACKNOWLEDGEMENT message.

Managed Object

Cell

Value Range and Step

4 access bursts, RLC/MAC control block

Unit

None

Default Value

RLC/MAC control block

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

It is recommended to use the RLC/MAC control block to send messages.


These two methods do not influence the successful rate of sending the
PACKET CONTROL ACKNOWLEDGEMENT message, so the default
value is used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Options

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.15.8 Access burst type (AccessType)


Full Name

Access burst type

Abbreviation

AccessType

3GPP Name

ACCESS_BURST_TYPE

3GPP Reference

3GPP TS 44.060 V5.19.0


4-368

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter is used at the MS side. It belongs to GPRS Cell Options IE and is broadcast to the MS in the SI13 message on BCCH and
in the PSI13 message on PSI13, indicating whether to use the 8-bit or
11-bit access burst in PRACH, PTCCH/U, and the PACKET CONTROL
Description

ACKNOWLEDGEMENT messages.

Managed Object

Cell

Value Range and Step

8 bits, 11 bits

Unit

None

Default Value

8 bits

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


11bits can minimize the C/I requirements for uplink signalling transfer.
This function should be enabled with caution if you do not have much
on-site operation experience.

Change Mode

Offline

Related features

ZGB-03-05-005 8/11 bit Access Burst

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Options

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.15.9 N3102 descrease step (PanDec)


Full Name

N3102 descrease step

Abbreviation

PanDec

3GPP Name

PAN_DEC

3GPP Reference

3GPP TS 44.060 V5.19.0


4-369

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is used at the MS side. It belongs to the GPRS cell


option parameters, and is broadcast to the MS in the SI13 message on
BCCH and in the PSI13 message on PACCH, , indicating the values of
the "PAN_DEC", "PAN_INC" and "PAN_MAX" parameters.After each cell
reselection, the MS will set the initial value of N3102 as the "PanMax"
value.
When the MS receives the "PACKET UPLINK ACK/NACK" message to
move V(S) forward, it adds PanInc to N3102 (but the maximum value
shall not exceed PanMax).
When the MS detects the stall condition (V(S) = V(A) + W(S)), T3182
will start.When it receives the "PACKET UPLINK ACK/NACK" message
that enables V(S) < V(A) + W(S), T3182 stops.If T3182 expires, the MS
will subtract PanDec from N3102.When the condition satisfies N3102
< 0, the MS will take cell reselection as abnormal release and perform
cell reselection.When one of PanDec, PanInc, and PanMax is zero,
Description

N3102 is invalid.

Managed Object

Cell

Value Range and Step

(4, 8, 12, 16, 20, 24, 28, 32)

Unit

None

Default Value

Default Value
Configuration Reason

To avoid the abnormal release of TB, and cell reselection, PanMax


applies the maximum value and PanDec applies the minimum value,
PanInc applies 2 times of PanDec in reference to CS RLT.
If the value of PAN_MAX and PAN_INC is increased, or the value of
PAN_DEC is reduced, the possibility of cell reselection is reduced
because TBF is abnormally released when the MS cannot receive the
Packet Uplink Ack message, and the utilization of radio resources is not

Configuration Rule and

high due to radio resources are occupied for a long time when the MS

Adjustment Suggestion

stops sending windows and cannot send data. If the value of PAN_MAX
and PAN_INC is reduced and the value of PAN_DEC is increased, it is
liable to cause TBF abnormal release of the MS and cell reselection,
thereby the normal release ratio of TBF in the cell is reduced and data
transmission rate is influenced.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

4-370
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Options

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.15.10 N3102 increase step (PanInc)


Full Name

N3102 increase step

Abbreviation

PanInc

3GPP Name

PAN_INC

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at the MS side. It belongs to the GPRS cell
option parameters, and is broadcast to the MS in the SI13 message on
BCCH and in the PSI13 message on PACCH, indicating the values of
the "PAN_DEC", "PAN_INC" and "PAN_MAX" parameters.After each cell
reselection, the MS will set the initial value of N3102 as the "PanMax"
value.
When the MS receives the "PACKET UPLINK ACK/NACK" message to
move V(S) forward, it adds PanInc to N3102 (but the maximum value
shall not exceed PanMax).
When the MS detects the stall condition (V(S) = V(A) + W(S)), T3182
will start.When it receives the "PACKET UPLINK ACK/NACK" message
that enables V(S) < V(A) + W(S), T3182 stops.If T3182 expires, the MS
will subtract PanDec from N3102.When the condition satisfies N3102
< 0, the MS will take cell reselection as abnormal release and perform
cell reselection.When one of PanDec, PanInc, and PanMax is zero,

Description

N3102 is invalid.

Managed Object

Cell

Value Range and Step

(4, 8, 12, 16, 20, 24, 28, 32)

Unit

None

Default Value

Default Value
Configuration Reason

To avoid the abnormal release of TB, and cell reselection, PanMax


applies the maximum value and PanDec applies the minimum value,
PanInc applies 2 times of PanDec in reference to CS RLT.
4-371

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If the value of PAN_MAX and PAN_INC is increased, or the value of


PAN_DEC is reduced, the possibility of cell reselection is reduced
because TBF is abnormally released when the MS cannot receive the
Packet Uplink Ack message, and the utilization of radio resources is not
Configuration Rule and

high due to radio resources are occupied for a long time when the MS

Adjustment Suggestion

stops sending windows and cannot send data. If the value of PAN_MAX
and PAN_INC is reduced and the value of PAN_DEC is increased, it is
liable to cause TBF abnormal release of the MS and cell reselection,
thereby the normal release ratio of TBF in the cell is reduced and data
transmission rate is influenced.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Options

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.15.11 N3102 max (PanMax)


Full Name

N3102 max

Abbreviation

PanMax

3GPP Name

PAN_MAX

3GPP Reference

3GPP TS 44.060 V5.19.0

4-372
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter is used at the MS side. It belongs to the GPRS cell


option parameters, and is broadcast to the MS in the SI13 message on
BCCH and in the PSI13 message on PACCH, , indicating the values of
the "PAN_DEC", "PAN_INC" and "PAN_MAX" parameters.After each cell
reselection, the MS will set the initial value of N3102 as the "PanMax"
value.
When the MS receives the "PACKET UPLINK ACK/NACK" message to
move V(S) forward, it adds PanInc to N3102 (but the maximum value
shall not exceed PanMax).
When the MS detects the stall condition (V(S) = V(A) + W(S)), T3182
will start.When it receives the "PACKET UPLINK ACK/NACK" message
that enables V(S) < V(A) + W(S), T3182 stops.If T3182 expires, the MS
will subtract PanDec from N3102.When the condition satisfies N3102
< 0, the MS will take cell reselection as abnormal release and perform
cell reselection.When one of PanDec, PanInc, and PanMax is zero,
Description

N3102 is invalid.

Managed Object

Cell

Value Range and Step

(4, 8, 12, 16, 20, 24, 28, 32)

Unit

None

Default Value

32

Default Value
Configuration Reason

To avoid the abnormal release of TB, and cell reselection, PanMax


applies the maximum value and PanDec applies the minimum value,
PanInc applies 2 times of PanDec in reference to CS RLT.
If the value of PAN_MAX and PAN_INC is increased, or the value of
PAN_DEC is reduced, the possibility of cell reselection is reduced
because TBF is abnormally released when the MS cannot receive the
Packet Uplink Ack message, and the utilization of radio resources is not

Configuration Rule and

high due to radio resources are occupied for a long time when the MS

Adjustment Suggestion

stops sending windows and cannot send data. If the value of PAN_MAX
and PAN_INC is reduced and the value of PAN_DEC is increased, it is
liable to cause TBF abnormal release of the MS and cell reselection,
thereby the normal release ratio of TBF in the cell is reduced and data
transmission rate is influenced.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

4-373
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Options

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.15.12 GPRS Phone Init Coding (GPRSInitattselt_0~GPRSInitatt


selt_3)
Full Name

GPRS Phone Init Coding

Abbreviation

GPRSInitattselt_0~GPRSInitattselt_3

3GPP Name

None
TS44.060: "Radio Link Control/Medium Access Control (RLC/MAC) pro-

3GPP Reference

tocol"
This parameter represents the default coding scheme corresponding to
the GPRS MS in such modes as the uplink init coding scheme, downlink
init coding scheme, uplink max coding scheme, and downlink max coding

Description

scheme.

Managed Object

Cell
Uplink init coding scheme: CS1, CS2, CS3, CS4;
Downlink init coding scheme: CS1, CS2, CS3, CS4;
Uplink max coding scheme: CS1, CS2, CS3, CS4;

Value Range and Step

Downlink max coding scheme: CS1, CS2, CS3, CS4.

Unit

None

Default Value

[CS2, CS2, CS4, CS4]

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The intermediate value is taken according to the network condition.


The value is dependent upon the radio signal quality in the network. If
the radio signal quality is poor, reduce the value. Otherwise, increase
the value.

Change Mode

Offline

Related features

None

Related Parameters

None

4-374
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Options

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.15.13 GPRS phones init code can be changed (InitAttachExch_0)


Full Name

GPRS phones init code can be changed

Abbreviation

InitAttachExch_0

3GPP Name

None
TS44.060: "Radio Link Control/Medium Access Control (RLC/MAC) pro-

3GPP Reference

tocol"
This parameter indicates whether the GPRS MS default code can be

Description

changed dynamically.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The default value is dependent upon the radio coverage.

Configuration Rule and

The value is dependent upon the radio signal quality in the network. If

Adjustment Suggestion

the radio signal quality fluctuates greatly, set the value as "Yes".

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

4-375
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Options

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.16 GPRS NC Survey Parameters


4.16.1 Packet idle mode (NcRepPerI)
Full Name

Packet idle mode

Abbreviation

NcRepPerI

3GPP Name

NC_REPORTING_PERIOD_I

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at the MS side. When the network is in NC or
NC3 mode, system broadcasts the parameter information to MS over the
BCCH channel through SI2Quater message. This parameter indicates
the period of MS reporting cell reselection survey in packet IDLE mode.
This parameter can also be sent to a certain MS over PACCH through
the PACKET MEASUREMENT ORDER or PACKET CELL CHANGE
ORDER message. The parameter carried in the PACKET CELL

Description

CHANGE ORDER message acts on the destination cell.

Managed Object

Cell

Value Range and Step

(0.48, 0.96, 1.92, 3.84, 7.68, 15.36, 30.72, 61.44)

Unit

Default Value

61.44

Default Value
Configuration Reason

The default value is dependent upon the protocol recommended value.

Configuration Rule and

NC2 function is not enabled currently, so it is better not to adjust the

Adjustment Suggestion

value.

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection


4-376

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

[Cell]CtrlOrder

Relationship

If NC1 or NC2 is enabled, this parameter is valid.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.16.2 Packet transmission mode (NcRerPerT)


Full Name

Packet transmission mode

Abbreviation

NcRerPerT

3GPP Name

NC_REPORTING_PERIOD_T

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at the MS side. When the network is in NC1 or
NC2 mode, system broadcasts the parameter information to MS over the
BCCH channel through SI2Quater message. This parameter indicates
the period of MS reporting cell reselection survey in packet transmission
mode. When Network control order is NC0, the parameter information is
not necessary to broadcast through PSI5 message.
This parameter can also be sent to a certain MS over PACCH through
the PACKET MEASUREMENT ORDER or PACKET CELL CHANGE
ORDER message. The parameter carried in the PACKET CELL

Description

CHANGE ORDER message acts on the destination cell.

Managed Object

Cell

Value Range and Step

(0.48, 0.96, 1.92, 3.84, 7.68, 15.36, 30.72, 61.44)

Unit

Default Value

3.84

Default Value
Configuration Reason

The default value is dependent upon the protocol recommended value.

4-377
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

the lower the value is, the more frequently the measurement reported,
Configuration Rule and

and the more accuracy of measurement calculation and cell reselection,

Adjustment Suggestion

but the more the signalling load is.Set the value in accordance with the
actual network load.

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection

Related Parameters

[Cell]CtrlOrder

Relationship

If NC1 or NC2 is enabled, this parameter is valid.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.16.3 Extended measurement report order (MeaOrder)


Full Name

Extended measurement report order

Abbreviation

MeaOrder

3GPP Name

MEASUREMENT_ORDER

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at the MS side. System broadcasts the
parameter information to MS through PSI1 message over PBCCH.
Extended measurement report order is to indicate the survey report
command of MS in a cell.

Description

This parameter indicates whether PSI5 is sent.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

This parameter is related to the configuration of PBCCH channel, so it

Configuration Reason

is recommended not to use the default value.


4-378

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Configuration Rule and

This parameter is related to the configuration of PBCCH channel, so it is

Adjustment Suggestion

recommended not to use the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.16.4 Network control order (CtrlOrder)


Full Name

Network control order

Abbreviation

CtrlOrder

3GPP Name

NETWORK_CONTROL_ORDER

3GPP Reference

3GPP TS 45.008 V6.19.0


The measurement report transmission mode of MS in the MM Ready status is set through the network control order. This parameter occupies
2 bits, and the NC0, NC1 and NC2 values can be set.In NC0 mode, MS
does not send the measurement report and automatically reselects a cell;
in NC1 mode, MS sends the measurement report to network and automatically reselects a cell; in NC2 mode, MS sends the measurement report
to network but cannot reselect a cell automatically. The network controls
cell reselection. This parameter information is broadcast to MS through

Description

the SI13 and SI2Quater messages over BCCH.

Managed Object

Cell

Value Range and Step

(NC0, NC1, NC2)

Unit

None

Default Value

NC0

4-379
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

The default value is dependant on the general network condition.

Configuration Rule and

Setting of the value is in accordance with the network load, network plan

Adjustment Suggestion

and service requirements.

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.16.5 NC2 mode between 2G and 3G (NC2For23G)


Full Name

NC2 mode between 2G and 3G

Abbreviation

NC2For23G

3GPP Name

None

3GPP Reference

None
This parameter determines whether enable the NC2 function between 2G
and 3G. The value 0 indicates that the NC2 function is not enabled for
interoperation between 2G and 3G. The value 1 indicates that the NC2
function is enabled between 2G and 3G. For the reselection mode applied
between 2G and 3G, perform an OR operation according to this functional
switch and the NC2 functional switch of CtrlOrder. That is, when CtrlOrder
is configured to NC2, the NC2 mode is applied for 2G-2G and 2G-3G.
When CtrlOrder is configured to NC0 and NC2For23G is configured to 1,
the NC0 mode is applied for 2G-2G and the NC2 mode is applied for 2G

Description

and 3G. This functional switch is the subset of CtrlOrder.

Managed Object

Cell

Value Range and Step

[0,1]
4-380

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

To apply the NC2 mode for only 2G or 3G, enable this switch.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.16.6 Serving Cell Load Threshold (ServCellLoadThr)


Full Name

Serving Cell Load Threshold

Abbreviation

ServCellLoadThr

3GPP Name

None

3GPP Reference

None
This parameter indicates that the system triggers reselection for network
control when the load of a 2G cell exceeds this threshold. The load is

Description

calculated based on channel usage.

Managed Object

Cell

Value Range and Step

0..100

Unit

Default Value

70

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.
4-381

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and

This parameter should be configured according to network operation

Adjustment Suggestion

planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.16.7 Serving Cell Capacity Threshold (ServCellCapaThr)


Full Name

Serving Cell Capacity Threshold

Abbreviation

ServCellCapaThr

3GPP Name

None

3GPP Reference

None
This parameter indicates that the system triggers reselection for network
control when the remaining access capacity of a 2G cell is lower than a
certain threshold. The remaining access capacity is the subtraction of the

Description

total capacity from the used capacity.

Managed Object

Cell

Value Range and Step

1..100

Unit

None

Default Value

30

Default Value

It is required to configure this parameter according to experienced

Configuration Reason

values.

Configuration Rule and

This parameter should be configured according to network operation

Adjustment Suggestion

planning.

Change Mode

Offline
4-382

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.16.8 Cell reselection control switch by serving cell traffic busy


(PsTrafResel)
Full Name

Cell reselection control switch by serving cell traffic busy

Abbreviation

PsTrafResel

3GPP Name

None

3GPP Reference

None
This parameter determines whether to enable reselection for the PS service of a cell. When this function is enabled, the system triggers reselection for network control if the load of this cell exceeds the 2G threshold.
If this function is not enabled, the system does not reference the load of

Description

this cell. 0: This function is not enabled; 1: This function is enabled.

Managed Object

Cell

Value Range and Step

[0,1]

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and

To trigger reselection for network control according to the congestion of

Adjustment Suggestion

a 2G cell, enable this switch.

Change Mode

Offline

Related features

None
4-383

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.16.9 NC hold time in non-drx mode (NcNoDrxPer)


Full Name

NC hold time in non-drx mode

Abbreviation

NcNoDrxPer

3GPP Name

NC_ NON_DRX_PERIOD

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at the MS side.When the network is in NC1 or
NC2 mode, system broadcasts the parameter information to MS over
BCCH through the SI2Quater message. MS stays in No-DRX mode
after the NC measurement report is sent.
This parameter information can also be sent to a certain MS over
PACCH through the PACKET MEASUREMENT ORDER or PACKET
CELL CHANGE ORDER message. The parameter value carried in the

Description

PACKET CELL CHANGE ORDER message acts on the destination cell.

Managed Object

Cell

Value Range and Step

(No non-DRX mode, 0.24, 0.48, 0.72, 0.96, 1.20, 1.44, 1.92)

Unit

Default Value

.48

Default Value

Setting of the default value (0.48 s) is to save power for MS and reduce

Configuration Reason

TBF establishment time.

4-384
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

In non-DRX mode, MS consumes more power. Therefore, when


DRX_Timer_Max is large, TBF establishment time can be reduced, but
Configuration Rule and

the power consumption of MS increases. When the value is small, the

Adjustment Suggestion

power of MS is saved, but the signalling load of the system increases


and data transmission delay increases because paging process is added
in DRX mode.

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection

Related Parameters

[Cell]CtrlOrder

Relationship

If NC1 or NC2 is enabled, this parameter is valid.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.16.10 Extended measurement report order (ExMeaOrder)


Full Name

Extended measurement report order

Abbreviation

ExMeaOrder

3GPP Name

EXT_MEASUREMENT_ORDER

3GPP Reference

3GPP TS 44.060 V5.19.0(R6)


This parameter is used at the MS side. System broadcasts to MS through
PSI5 message. This parameter indicates whether the MS performs extended survey. In addition, it indicates how to interpret the other extended
survey parameters (Type of extended measurement report and Report
period of extended measurement). The values are as follows: EM0: MS
should not perform extended survey; EM1: MS should perform extended

Description

survey and report to network.

Managed Object

Cell

Value Range and Step

(EM0, EM1)

Unit

None
4-385

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

EM0

Default Value

This parameter is related to the configuration of PBCCH channel, so it

Configuration Reason

is recommended not to use the default value.

Configuration Rule and

This parameter is related to the configuration of PBCCH channel, so it is

Adjustment Suggestion

recommended not to use the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.16.11 Type of extended measurement report (ExtRepType)


Full Name

Type of extended measurement report

Abbreviation

ExtRepType

3GPP Name

EXT_REPORTING_TYPE

3GPP Reference

3GPP TS 44.060 V5.19.0(R6)


This parameter is used at the MS side. It belongs to the extended
measurement parameters, and it is broadcast to the MS in the PSI5
message, indicating the type of the extended measurement report of
MS.System sends the parameter information through the PSI5 message
when Extended measurement report order is EM1.
The values are as follows: Type I: This type of report must be extended
if the frequency points for the extended survey are among the six
strongest carrier frequencies, even if the BSIC decoding is successful.
The report should cover the receiving signal level and the successfully

Description

decoded BSIC (if any);

4-386
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Type II: This type of report must be extended if all the frequency
points for the extended survey are located in the six strongest carrier
frequencies, the BSIC decoding is successful and the NCC part is
allowed for survey. The report should cover the receiving signal level
and the successfully decoded BSIC;
Type III: Use this type of report to report all the frequency points for the
extended survey. No BSIC decoding is necessary. The report should
contain the receiving signal level. Besides, the interference of each
carrier frequency shall be reported.
Managed Object

Cell

Value Range and Step

Type1, Type2, Type3

Unit

None

Default Value

Type 1

Default Value

This parameter is related to the configuration of PBCCH channel, so it

Configuration Reason

is recommended not to use the default value.

Configuration Rule and

This parameter is related to the configuration of PBCCH channel, so it is

Adjustment Suggestion

recommended not to use the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.16.12 Report period of extended measurement (ExtRepPer)


Full Name

Report period of extended measurement

Abbreviation

ExtRepPer

4-387
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

EXT_REPORTING_PERIOD

3GPP Reference

3GPP TS 44.060 V5.19.0(R6)


This parameter is used at the MS side. It belongs to the extended measurement parameters, and it is broadcast to the MS in the PSI5 message, indicating the time interval between the extended measurement reports.System sends the parameter information through the PSI5 message

Description

when Extended measurement report order is EM1.

Managed Object

Cell

Value Range and Step

(60, 120, 240, 480, 960, 1920, 3840, 7680)

Unit

Default Value

1920

Default Value

This parameter is related to the configuration of PBCCH channel, so it

Configuration Reason

is recommended not to use the default value.

Configuration Rule and

This parameter is related to the configuration of PBCCH channel, so it is

Adjustment Suggestion

recommended not to use the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.16.13 The size of test report's slip window (Wnd)


Full Name

The size of test report's slip window

Abbreviation

Wnd

3GPP Name

None

4-388
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

3GPP Reference

None
When the network in NC2 mode controls the cell reselection, this parameter is used.When the number of measurement reports reaches the setting
value of this parameter, average processing is done for the measurement

Description

reports.

Managed Object

Cell
1.. 8

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value as this, so as to ensure the

Configuration Reason

accuracy and rapidness of reselection.

Configuration Rule and


Adjustment Suggestion

The smaller the window size is, the greater the random interference
is. If the window size is too large, the real-time-change of radio signal
cannot be reflected.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.16.14 Minimum measurement reports in slip window to avoid


penalty (AllowedRepNum)
Full Name

Minimum measurement reports in slip window to avoid penalty

Abbreviation

AllowedRepNum

3GPP Name

None
4-389

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

None
When the network in NC2 mode controls the cell reselection, this parameter is used.When the adjacent cell receives the average level, and the
number of valid measurement reports received in slip window is lower

Description

than the setting value, this calculation shall be punished.

Managed Object

Cell
1 .. 6

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value as this, so as to ensure the

Configuration Reason

accuracy and rapidness of reselection.


The larger this parameter value is, the more is the number of penalties

Configuration Rule and


Adjustment Suggestion

performed by the adjacent cell, the higher the reselection threshold is. In
that case, the network is unable to notify the MS of reselection, which
may lead to TBF failure occurs. The smaller the parameter value is, the
lower the reselection threshold is, which may cause frequent reselection.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS NC Survey

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-390
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.17 GPRS Power Control Parameters


4.17.1 Filter period in the packet idle mode (T_AVG_W)
Full Name

Filter period in the packet idle mode

Abbreviation

T_AVG_W

3GPP Name

T_AVG_W

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is one of the global power control and
GPRS power control parameters, and is broadcast to an MS in the PSI1,
PSI13 and SI13 messages. This parameter indicates the filter period of a

Description

signal intensity for power control in packet idle mode.

Managed Object

Cell
0..31
0: The filter period is 2(0/2)/6multi-frames;
1: The filter period is 2(1/2)/6multi-frames;
...
25: The filter period is 2(25/2)/6multi-frames;

Value Range and Step

26..31: The filter period is 2(25/2)/6multi-frames

Unit

Default Value

Default Value
Configuration Reason

This parameter should be set on demand of radio environment.


This parameter is used when an MS surveys the downlink signal intensity

Configuration Rule and


Adjustment Suggestion

in packet idle mode, and calculates the C value. The formula is: Cn =
(1-a) Cn-1 + a Cblock, n, , a = 1/MIN(n, MAX(5, TAVG_W*NDRX))..
For the details, see 45008 10.2.3.1.1. Currently this parameter is not
supported and it is 0 by default.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

4-391
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Power


Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.17.2 Filter period in packet transmission mode (T_AVG_T)


Full Name

Filter period in packet transmission mode

Abbreviation

T_AVG_T

3GPP Name

T_AVG_T

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is one of the global power control and
GPRS power control parameters, and is broadcast to an MS in the PSI1,
PSI13 and SI13 messages. This parameter indicates the filter period of

Description

the signal intensity for power control in the packet transmission mode.

Managed Object

Cell
0..31
0: The filter period is 2(0/2)/6multi-frames;
1: The filter period is 2(1/2)/6multi-frames;
...
25: The filter period is 2(25/2)/6multi-frames;

Value Range and Step

26..31: Reserved

Unit

Default Value

Default Value
Configuration Reason

This parameter should be set on demand of radio environment.


This parameter is used when an MS surveys the downlink signal

Configuration Rule and


Adjustment Suggestion

intensity in packet transmission mode, and calculates the C value. The


formula is: Cn = (1-b) Cn-1 + b SS n, , b = 1/(6*TAVG_T).. For the
details, see 45008 10.2.3.1.2. Currently this parameter is not supported
and it is 0 by default.

Change Mode

Offline

Related features

None

Related Parameters

None

4-392
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Power


Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.17.3 PSI4 sending mark (Psi4Send)


Full Name

PSI4 sending mark

Abbreviation

Psi4Send

3GPP Name

INT_MEAS_CHANNEL_LIST_AVAIL

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is named as INT_MEAS_CHANNEL_LIST_AVAIL. The parameter is one of the global power control parameters, and is broadcast to the MS in the PSI1 message. This parameter indicates whether to broadcast the optional PSI4 message. If PSI4
is to be broadcast, it will contain a list of channels that interfere with the

Description

survey.

Managed Object

Cell
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is relevant to PBCCH. Keep the default setting.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

None

4-393
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.17.4 Power control measurement channel (PcMeasChan)


Full Name

Power control measurement channel

Abbreviation

PcMeasChan

3GPP Name

PC_MEAS_CHAN

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is one of the global power control
and GPRS power control parameters, and is broadcast to an MS in the
PSI1, PSI13 and SI13 messages. This parameter indicates the position

Description

where the downlink power strength is surveyed for uplink power control.

Managed Object

Cell

Value Range and Step

BCCH, PDCH

Unit

None

Default Value

BCCH

Default Value
Configuration Reason

This parameter should be set on demand of user needs.

Configuration Rule and


Adjustment Suggestion

Set it with the default value. MS surveys the BCCH uplink power.

Change Mode

Offline

Related features

None

Related Parameters

None

4-394
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Power


Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.17.5 Power control parameter (Alpha)


Full Name

Power control parameter

Abbreviation

Alpha

3GPP Name

ALPHA

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is one of the global power control
and GPRS power control parameters, and is broadcast to an MS in the
PSI1, PSI13 and SI13 messages. This parameter determines the MS

Description

transmission power control parameter Alpha ().

Managed Object

Cell
0..10
If the parameter for MS transmitting power control is Alpha (),
0: = 0.0;
1: = 0.1;
...
10: = 1.0;

Value Range and Step

11..15: = 1.0

Unit

None

Default Value

Default Value
Configuration Reason

This parameter should be set on demand of radio environment.

Configuration Rule and

Lower the value of this power control parameter to decrease the MS

Adjustment Suggestion

transmission power reliance on the downlink level.

4-395
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.17.6 Filter constant of power control (N_AVG_I)


Full Name

Filter constant of power control

Abbreviation

N_AVG_I

3GPP Name

N_AVG_I

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is one of the global power control
and GPRS power control parameters, and is broadcast to an MS in the
PSI1, PSI13 and SI13 messages. This parameter is a filter constant used

Description

to optimize the interference signal intensity in power control.

Managed Object

Cell
0..15

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter should be set on demand of radio environment.

Configuration Rule and

This parameter is used at MS side. It is a factor used to calculate the

Adjustment Suggestion

downlink signal intensity. The default value is recommended.

Change Mode

Offline
4-396

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Power


Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.17.7 Power descending on PBCCH (Pb)


Full Name

Power descending on PBCCH

Abbreviation

Pb

3GPP Name

None

3GPP Reference

None
Power descending on PBCCH

Description

Unsupported

Managed Object

Cell

Value Range and Step

Unit

2 dB

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None
4-397

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Power Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18 GPRS Cell Reselection Parameters


4.18.1 Cell reselection offset (ReselOff_0)
Full Name

Cell reselection offset

Abbreviation

ReselOff_0

3GPP Name

GPRS_RESELECT_OFFSET

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. It is broadcast to MS via system
message from BTS. In the GPRS system, C32 is used as the standard
for cell re-selection. Similar to the C2 standard in GSM, a cell
re-selection offset parameter (ReselOff) is included for C32 standard
calculation. This parameter can be excluded in packet system message
when the offset value is 0 dB.
This parameter is used during re-selection in idle status. It only functions

Description

when PBCCH is configured.

Managed Object

Cell
0..31
0: -52 dB;
1: -48 dB;
...
22: +12 dB;
...
31: +48 dB
-52 dB .. -12 dB. The step between 12 dB .. 48 dB is 4 dB. The step

Value Range and Step

between -12 dB .. 12 dB is 2 dB.

Unit

2 dB
4-398

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

ZGO-02-02-009 Support of C31 and C32 Criteria

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.2 Cell reselection offset2 (ReselOff_1)


Full Name

Cell reselection offset2

Abbreviation

ReselOff_1

3GPP Name

GPRS_RESELECT_OFFSET

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. The parameter information is
passed to MS through PACCH. In the GPRS system, C32 is used as the
standard for cell re-selection. Similar to the C2 standard in GSM, a cell
re-selection offset parameter (ReselOff) is included for C32 standard
calculation. This parameter can be excluded in packet system message
when the offset value is 0 dB.
This parameter indicates the parameter used during re-selection in

Description

transmission state.

Managed Object

Cell

4-399
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0..31
0: -52 dB;
1: -48 dB;
...
22: +12 dB;
...
Value Range and Step

31: +48 dB

Unit

2 dB

Default Value

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

ZGO-02-02-009 Support of C31 and C32 Criteria

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.3 Temporary offset of cell reselection (TempOffset_0)


Full Name

Temporary offset of cell reselection

Abbreviation

TempOffset_0

3GPP Name

GPRS_TEMPORARY_OFFSET

3GPP Reference

3GPP TS 45.008 V5.22.0

4-400
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter is used at MS side. It is broadcast to MS via system


message from BTS. In the GPRS system, C32 is used as the standard
for cell re-selection. Similar to C2 standard in the GSM system, a
TempOffset parameter is included to provide a negative offset for C32
standard calculation.
This parameter is used during re-selection in idle status. It only functions
Description

when PBCCH is configured.

Managed Object

Cell

Value Range and Step

0, 10, 20, 30, 40, 50, 60, infinite

Unit

dB

Default Value

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

ZGO-02-02-009 Support of C31 and C32 Criteria

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.4 Temporary offset of cell reselection2 (TempOffset_1)


Full Name

Temporary offset of cell reselection2

Abbreviation

TempOffset_1

3GPP Name

GPRS_TEMPORARY_OFFSET

4-401
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. The parameter information is
passed to MS through PACCH. In the GPRS system, C32 is used as the
standard for cell re-selection. Similar to C2 standard in the GSM system,
a TempOffset parameter is included to provide a negative offset for C32
standard calculation.
This parameter indicates the parameter used during re-selection in

Description

transmission state.

Managed Object

Cell

Value Range and Step

0, 10, 20, 30, 40, 50, 60, infinite

Unit

dB

Default Value

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

ZGO-02-02-009 Support of C31 and C32 Criteria

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.5 Penalty time of cell reselection 0 (PenalTime_0)


Full Name

Penalty time of cell reselection 0

Abbreviation

PenalTime_0

4-402
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

3GPP Name

GPRS_PENALTY_TIME

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. It is broadcast to MS via system
message from BTS. In the GPRS system, C32 is used as the standard
for cell re-selection. Similar to C2 standard in the GSM system, a
TempOffset parameter is included to provide a negative offset for C32
standard calculation. The period of time during which the offset takes
effect is determined by the PenalTime parameter.
This parameter is used during re-selection in idle status. It only functions

Description

when PBCCH is configured.

Managed Object

Cell
0..31
0: 10 s;
1: 20 s;
...

Value Range and Step

31: 320 s

Unit

10 s

Default Value

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-403
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.18.6 Penalty time of cell reselection 1 (PenalTime_1)


Full Name

Penalty time of cell reselection 1

Abbreviation

PenalTime_1

3GPP Name

GPRS_PENALTY_TIME

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. The parameter information is
passed to MS through PACCH. In the GPRS system, C32 is used as the
standard for cell re-selection. Similar to C2 standard in the GSM system,
a TempOffset parameter is included to provide a negative offset for C32
standard calculation. The period of time during which the offset takes
effect is determined by the PenalTime parameter.
This parameter indicates the parameter used during re-selection in

Description

transmission state.

Managed Object

Cell
0..31
0: 10 s;
1: 20 s;
...

Value Range and Step

31: 320 s

Unit

10 s

Default Value

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Reselection

4-404
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.7 Interval of reselecting the same cell (T_Resel_0)


Full Name

Interval of reselecting the same cell

Abbreviation

T_Resel_0

3GPP Name

T_RESEL

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is broadcast to MS via system
message from BTS. When an MS performs a cell re-selection that
causes abnormal release in this cell, the MS is not allowed to re-select
this cell within the T_RESEL period, unless there is no other cells
for selection. When the time period indicated by this parameter is 5 s
(default value), it is not necessary to broadcast this parameter to MS
through PSI3 message.
This parameter is used during re-selection in idle status. It only functions

Description

when PBCCH is configured.

Managed Object

Cell

Value Range and Step

5, 10, 15, 20, 30, 60, 120, 300

Unit

Default Value

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

4-405
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.8 Interval of reselecting the same cell 2 (T_Resel_1)


Full Name

Interval of reselecting the same cell 2

Abbreviation

T_Resel_1

3GPP Name

T_RESEL

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. The parameter information is passed
to MS through PACCH. When an MS performs a cell re-selection that
causes abnormal release in this cell, the MS is not allowed to re-select
this cell within the T_RESEL period, unless there is no other cells
for selection. When the time period indicated by this parameter is 5 s
(default value), it is not necessary to broadcast this parameter to MS
through PSI3 message.
This parameter indicates the parameter used during re-selection in

Description

transmission state.

Managed Object

Cell

Value Range and Step

5, 10, 15, 20, 30, 60, 120, 300

Unit

Default Value

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

The period of time indicated by this parameter determines the period

Adjustment Suggestion

during which the MS is not allowed to re-select this cell.

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

0
4-406

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.9 Threshold of HSC signal level (HCS_Thr_0)


Full Name

Threshold of HSC signal level

Abbreviation

HCS_Thr_0

3GPP Name

HCS_THR

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is an HCS parameter, which is
broadcast to an MS via system message from BTS. It indicates the HCS
signal strength threshold of the cell.
This parameter is used during re-selection in idle status. It only functions

Description

when PBCCH is configured.

Managed Object

Cell
0..31
0: -110 dBm
1: -108 dBm
...

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None
4-407

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.10 Threshold of HSC signal level 2 (HCS_Thr_1)


Full Name

Threshold of HSC signal level 2

Abbreviation

HCS_Thr_1

3GPP Name

HCS_THR

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is an HCS parameter, which is
broadcast to MS through PACCH. It indicates the HCS signal strength
threshold of the cell.
This parameter indicates the parameter used during re-selection in

Description

transmission state.

Managed Object

Cell
0..31
0: -110 dBm
1: -108 dBm
...

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and


Adjustment Suggestion
Change Mode

The parameter indicates the minimum access electricity level threshold.


It is easier to access a cell when the threshold gets lower. Increase the
threshold to limit the MS access to a cell.
Offline

4-408
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related features

ZGO-02-02-012 Network Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Reselection
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.11 HCS Priority (PrioClass_0)


Full Name

HCS Priority

Abbreviation

PrioClass_0

3GPP Name

PRIORITY_CLASS

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is an HCS parameter, which is
broadcast to an MS via system message from BTS. It specifies the HCS
priority of a cell.
This parameter is used during re-selection in idle status. It only functions

Description

when PBCCH is configured.

Managed Object

Cell
0..7

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline
4-409

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Reselection
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.12 HCS Priority 2 (PrioClass_1)


Full Name

HCS Priority 2

Abbreviation

PrioClass_1

3GPP Name

PRIORITY_CLASS

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is an HCS parameter, which is
broadcast to MS through PACCH. It specifies the HCS priority of a cell.
This parameter indicates the parameter used during re-selection in

Description

transmission state.

Managed Object

Cell
0..7

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

The priority of an HCS cell gets higher with the increase of the parameter

Adjustment Suggestion

value.

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection


4-410

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Reselection
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.13 C31 hysteresis (C31_Hyst_0)


Full Name

C31 hysteresis

Abbreviation

C31_Hyst_0

3GPP Name

C31_HYST

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is broadcast to MS through system
message from BTS. It indicates whether CellReselHys parameter
functions with C31 standard.
This parameter is used during re-selection in idle status. It only functions

Description

when PBCCH is configured.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

ZGO-02-02-009 Support of C31 and C32 Criteria

4-411
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Reselection
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.14 C31 hysteresis 2 (C31_Hyst_1)


Full Name

C31 hysteresis 2

Abbreviation

C31_Hyst_1

3GPP Name

C31_HYST

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is broadcast to MS through
PACCH. It indicates whether CellReselHys parameter functions with
C31 standard.
This parameter indicates the parameter used during re-selection in

Description

transmission state.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This is a NC2 reset parameter. Set the parameter "Yes" to function the

Adjustment Suggestion

reset hysteresis with the C31 standard.

Change Mode

Offline

Related features

ZGO-02-02-009 Support of C31 and C32 Criteria

4-412
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Reselection
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.15 GPRS cell reselection hysteresis (ReselHys_0)


Full Name

GPRS cell reselection hysteresis

Abbreviation

ReselHys_0

3GPP Name

GPRS_CELL_RESELECT_HYSTERESIS

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. It is broadcast to MS through system
message from BTS.
When an MS is conducting GPRS cell selection, it must go through
location updating process after cell re-selection if the original cell and
destination cell are in different locations. C32 values obtained at the
boundary of two adjacent cells fluctuate because of fading characteristic
of radio channels, which causes MS to select cell frequently.
The interval between the two cell re-selection actions by an MS is not
shorter than 15 s. However, 15 s is a very short period of time in terms
of location update. The frequent cell re-selections increase the signaling
traffic on the network, thus the radio resources cannot be fully utilized.
As an MS cannot respond to paging during a location update, the call
completion rate is deceased.
A parameter, named Cell Re-selecting Hysteresis (CRH), is created to
solve this problem. MS will activate the cell re-selection only when the
signal level of adjacent cell (whose location zone is different from that
of the local cell) is greater than that of the local cell, and meanwhile the

Description

value difference must be greater than that required by the parameter.

4-413
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

When signaling traffic overload often occurs due to great demand of


services, increase the value of the cell re-selection parameters for
adjacent cells with different LAC.
When adjacent cells in different location zone have a large overlapped
coverage area, increase the value of the cell re-selection parameters.
When two adjacent cells with different LACs have poor coverage at the
border, that is, when there is a coverage gap, or the border area is at a
place with few slow moving objects, such as the expressway, the CRH
parameter shall be set with the value between 1 .. 3 (that is, the CRH
level should fall into the value range of 2 dB .. 6 dB).
This parameter is used during re-selection in idle status. It only functions
when PBCCH is configured.
Managed Object

Cell

Value Range and Step

0, 2, 4, 6, 8, 10, 12, 14

Unit

dB

Default Value

Default Value

This parameter is relevant to PBCCH, and is not recommended to be

Configuration Reason

used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

ZGO-02-02-009 Support of C31 and C32 Criteria

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-414
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.18.16 GPRS cell reselection hysteresis 2 (ReselHys_1)


Full Name

GPRS cell reselection hysteresis 2

Abbreviation

ReselHys_1

3GPP Name

GPRS_CELL_RESELECT_HYSTERESIS

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. The parameter information is passed
to MS through PACCH.
When an MS is conducting GPRS cell selection, it must go through
location updating process after cell re-selection if the original cell and
destination cell are in different locations. C32 values obtained at the
boundary of two adjacent cells fluctuate because of fading characteristic
of radio channels, which causes MS to select cell frequently.
The interval between the two cell re-selection actions by an MS is not
shorter than 15 s. However, 15 s is a very short period of time in terms
of location update. The frequent cell re-selections increase the signaling
traffic on the network, thus the radio resources cannot be fully utilized.
As an MS cannot respond to paging during a location update, the call
completion rate is deceased.
A parameter, named Cell Re-selecting Hysteresis (CRH), is created to
solve this problem. MS will activate the cell re-selection only when the
signal level of adjacent cell (whose location zone is different from that
of the local cell) is greater than that of the local cell, and meanwhile the
value difference must be greater than that required by the parameter.
When signaling traffic overload often occurs due to great demand of
services, increase the value of the cell re-selection parameters for
adjacent cells with different LAC.
When adjacent cells in different location zone have a large overlapped
coverage area, increase the value of the cell re-selection parameters.
When two adjacent cells with different LACs have poor coverage at the
border, that is, when there is a coverage gap, or the border area is at a
place with few slow moving objects, such as the expressway, the CRH
parameter shall be set with the value between 1 .. 3 (that is, the CRH
level should fall into the value range of 2 dB .. 6 dB).
This parameter indicates the parameter used during re-selection in

Description

transmission state.

Managed Object

Cell

Value Range and Step

0, 2, 4, 6, 8, 10, 12, 14

Unit

dB

Default Value

Default Value
Configuration Reason

This parameter should be set on demand of radio environment.


4-415

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

When signaling traffic overload often occurs due to great demand of


services, increase the value of the cell re-selection parameters of
adjacent cells with different LAC.
When adjacent cells in different location zone have a large overlapped
Configuration Rule and

coverage area, increase the value of the cell re-selection parameters.

Adjustment Suggestion

When two adjacent cells with different LACs have poor coverage at the
border, that is, when there is a coverage gap, or the border area is at a
place with few slow moving objects, such as the expressway, the CRH
parameter shall be set with the value between 1 .. 3 (that is, the CRH
level should fall into the value range of 2 dB .. 6 dB).

Change Mode

Offline

Related features

ZGO-02-02-009 Support of C31 and C32 Criteria

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.17 Routing reselection hysteresis (RaReselHys_0)


Full Name

Routing reselection hysteresis

Abbreviation

RaReselHys_0

3GPP Name

RA_RESELECT_HYSTERESIS

3GPP Reference

3GPP TS 44.060 V5.19.0

4-416
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter is used at MS side. It is broadcast to MS through system


message by BTS. This parameter specifies an extra hysteresis value
used when an MS in STANDBY and READY status selects a cell in
another routing area. When this parameter has the same value as the
CellReselHys parameter, it is not necessary to broadcast it through the
PSI3 message.
This parameter is used during re-selection in idle status. It only functions
Description

when PBCCH is configured.

Managed Object

Cell

Value Range and Step

0, 2, 4, 6, 8, 10, 12, 14

Unit

dB

Default Value

Default Value
Configuration Reason

This parameter should be set on demand of radio environment.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Reselection
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.18 Routing reselection hysteresis 2 (RaReselHys_1)


Full Name

Routing reselection hysteresis 2

Abbreviation

RaReselHys_1

4-417
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

RA_RESELECT_HYSTERESIS

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter is used at MS side. The parameter information is passed
to MS through PACCH. This parameter specifies an extra hysteresis
value used when an MS in STANDBY and READY status selects a cell
in another routing area. When this parameter has the same value as
the CellReselHys parameter, it is not necessary to broadcast it through
the PSI3 message.
This parameter indicates the parameter used during re-selection in

Description

transmission state.

Managed Object

Cell

Value Range and Step

0, 2, 4, 6, 8, 10 12, 14

Unit

dB

Default Value

Default Value
Configuration Reason

This parameter should be set on demand of radio environment.

Configuration Rule and

When adjacent cells in different routing zone have a large overlapped

Adjustment Suggestion

coverage area, increase the value of the cell re-selection parameters.

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Reselection
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-418
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.18.19 Random access attempt permitted (RadAcRetry_0)


Full Name

Random access attempt permitted

Abbreviation

RadAcRetry_0

3GPP Name

None

3GPP Reference

None
This parameter is used at MS side. The parameter information is
broadcast to MS through system message from BTS, indicating whether
an MS is allowed to access another cell (if it exists).
When an abnormal release occurs during the packet transmission, the
MS discards all the running TBFs. If the MS is allowed to access other
cells, it should perform abnormal cell re-selection, and establish TBF
after entering new cell. If other suitable cells exist, an MS cannot select
the original cell within T_RESEL seconds.
This parameter is used during re-selection in idle status. It only functions

Description

when PBCCH is configured.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

This parameter is relevant to PBCCH, and is not recommended to be

Configuration Reason

used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

4-419
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

4.18.20 Random access attempt permitted 2 (RadAcRetry_1)


Full Name

Random access attempt permitted 2

Abbreviation

RadAcRetry_1

3GPP Name

None

3GPP Reference

None
This parameter is used at MS side. The parameter information is passed
to MS through PACCH, indicating whether an MS is allowed to access
another cell (if it exists).
When an abnormal release occurs during the packet transmission, the
MS discards all the running TBFs. If the MS is allowed to access other
cells, it should perform abnormal cell re-selection, and establish TBF
after entering new cell. If other suitable cells exist, an MS cannot select
the original cell within T_RESEL seconds.
This parameter indicates the parameter used during re-selection in

Description

transmission state.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

4-420
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.21 Usage of cell reselection offset (C32_Qual_0)


Full Name

Usage of cell reselection offset

Abbreviation

C32_Qual_0

3GPP Name

C32_QUAL

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. The parameter information is
broadcast to MS through system message from BTS, indicating whether
to use the exception rule when adopting ReselOff.
This parameter is used during re-selection in idle status. It is enabled

Description

only when PBCCH is configured.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

4-421
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.22 Usage of cell reselection offset 2 (C32_Qual_1)


Full Name

Usage of cell reselection offset 2

Abbreviation

C32_Qual_1

3GPP Name

C32_QUAL

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. The parameter information is passed
to the MS through PACCH, indicating whether to use the exception rule
for ReselOff.
This parameter indicates the parameter used during re-selection in

Description

transmission state.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

This parameter impacts the C31 and C32 re-selection rule, and is not

Configuration Reason

recommended to be used.

Configuration Rule and


Adjustment Suggestion

This parameter should be set on demand of user needs. If it is set "Yes",


ReselOff will be set with a suggested default value according to the rules
described in protocol 45008 10.1.3 Cell Re-selection Algorithm.

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
4-422

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.23 GPRS access minimal signal level 1 (RxLevAsMin_0)


Full Name

GPRS access minimal signal level 1

Abbreviation

RxLevAsMin_0

3GPP Name

GPRS_RXLEV_ACCESS_MIN

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. The parameter information is
broadcast to MS through system message from BTS.
This parameter indicates the minimum receiving level for MS access to
this system (GPRS). To prevent the MS from accessing the system at
a low receiving signal level (usually, the communication quality cannot
guarantee normal communication), which will cause unreasonable waste
of radio resources. It is stipulated in the GSM system design that the
receiving level should be greater than a threshold level for MS to access
the network, that is, the minimum level for an MS to access a cell.
In addition, this parameter also serves as one of the standards for an
MS to make the cell selection and re-selection (a parameter used to
calculate C31 and C32).
This parameter is used during re-selection in idle status. It is enabled

Description

only when PBCCH is configured.

Managed Object

Cell
0..63
0: -110 dBm;
1: -110 dBm .. -109 dBm;
2: -109 dBm .. -108 dBm;
...
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

12

4-423
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

This parameter should be set on demand of radio environment.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.24 GPRS access minimal signal level 2 (RxLevAsMin_1)


Full Name

GPRS access minimal signal level 2

Abbreviation

RxLevAsMin_1

3GPP Name

GPRS_RXLEV_ACCESS_MIN

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. The parameter information is passed
to MS through PACCH.
This parameter indicates the minimum receiving level for MS access to
this system (GPRS). To prevent the MS from accessing the system at
a low receiving signal level (usually, the communication quality cannot
guarantee normal communication), which will cause unreasonable waste
of radio resources. It is stipulated in the GSM system design that the
receiving level should be greater than a threshold level for MS to access

Description

the network, that is, the minimum level for an MS to access a cell.

4-424
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

In addition, this parameter also serves as one of the standards for an


MS to make the cell selection and re-selection (a parameter used to
calculate C31 and C32).
This parameter indicates the parameter used during re-selection in
transmission state.
Managed Object

Cell
0..63
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
2: -109 dBm .. -108 dBm;
...
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

12

Default Value
Configuration Reason

This parameter should be set on demand of radio environment.

Configuration Rule and


Adjustment Suggestion

This parameter is used for cell re-selection.

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-425
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.18.25 Priority threshold (Prio_Thr)


Full Name

Priority threshold

Abbreviation

Prio_Thr

3GPP Name

PRIO_THR

3GPP Reference

3GPP TS44.018 V5.22.0


The parameter information is broadcast to MS through SI4, SI6 and SI7
messages. This parameter is correlated with RXLEV_ACCESS_MIN, and

Description

is used for calculation of C4 standard.

Managed Object

Cell

Value Range and Step

0, 6, 12, 18, 24, 30, 36, infinite

Unit

dB

Default Value

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

The parameter impacts in PBCCH channel configuration, and C31 and

Adjustment Suggestion

C32 re-selection standards. It is not recommended to be used.

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.26 HCS exist (HCS_Exist_0)


Full Name

HCS exist
4-426

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Abbreviation

HCS_Exist_0

3GPP Name

None

3GPP Reference

None
This parameter is used at MS side. This is a Hierarchical Cell Structure
(HCS) parameter and the parameter information is broadcast to MS
through system message from BTS. This parameter indicates whether
the HCS parameters (PriorityClass and HCSThr) exist in the cell. If this
cell does not use HCS parameters, an MS will ignore HCS parameters
of other cells, then all cells use infinite threshold of HCS signal level.
This parameter is used during re-selection in idle status. It is enabled

Description

only when PBCCH is configured.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The parameter impacts in PBCCH channel configuration, and C31 and

Configuration Reason

C32 re-selection standards. It is not recommended to be used.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-427
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.18.27 HCS exist 2 (HCS_Exist_1)


Full Name

HCS exist 2

Abbreviation

HCS_Exist_1

3GPP Name

None

3GPP Reference

None
This parameter is used at MS side. This is a Hierarchical Cell Structure
(HCS) parameter and the parameter information is passed to MS
through PACCH. This parameter indicates whether the HCS parameters
(PriorityClass and HCSThr) exist in the cell. If this cell does not use HCS
parameters, an MS will ignore HCS parameters of other cells, then all
cells use infinite threshold of HCS signal level.
This parameter indicates the parameter used during re-selection in

Description

transmission state.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

This parameter is relevant to PBCCH, and is not recommended to be

Configuration Reason

used.
When the radio network have different cell re-selection priority, set

Configuration Rule and


Adjustment Suggestion

this parameter "Yes" if the C31 judgment criteria for the priority cell
re-selection and signal level threshold is applied. When more than one
cell has the highest priority, C32 judgment criteria should be used for the
cells with a same priority.

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None
4-428

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

None

4.18.28 GPRS MAX initial access signal level (MsTxMaxCch_0)


Full Name

GPRS MAX initial access signal level

Abbreviation

MsTxMaxCch_0

3GPP Name

GPRS_MS_TXPWR_MAX_CCH

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. The parameter information is
broadcast to MS through system message from BTS.
Network controls the MS transmit power during communication between
MS with BTS. MS power control is implemented with power control
commands. MS output transmit power must meet the radio network
standard. If an MS cannot output this power because of low power level,
it gives an power closest to the standard.
This parameter is also used for MS cell selection and re-selection,
involved in the calculation of C1 and C2 values. If this parameter value
is too high, the MS close to BTS will interfere with the adjacent channel;
if the value is too low, the success rate of MS access at the edge of
cell will be low.
The setting for this parameter should follow this principle: guarantee a
certain success rate of MS access at the cell edge while decreasing the
access level of MS as much as possible. Obviously, the coverage area
increases with the uplift of MS output power. It is recommended to set
this parameter 5 (for GSM900MS) and 2 (for GSM1800MS).
After the parameter is set, make a dial test at the cell boundary. Test the
success rate of MS access and access time under different parameter
settings to determine whether to increase or decrease the value of the
parameter.
For the parameter value, see the appendix.
This parameter is used during re-selection in idle status. It is enabled

Description

only when PBCCH is configured.

Managed Object

Cell
0..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

This parameter is relevant to PBCCH, and is not recommended to be

Configuration Reason

used.

4-429
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.18.29 GPRS MAX initial access signal level 2 (MsTxMaxCch_1)


Full Name

GPRS MAX initial access signal level 2

Abbreviation

MsTxMaxCch_1

3GPP Name

GPRS_MS_TXPWR_MAX_CCH

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used at MS side. The parameter information is passed
to MS through PACCH.
Network controls the MS transmit power during communication between
MS with BTS. MS power control is implemented with power control
commands. MS output transmit power must meet the radio network
standard. If an MS cannot output this power because of low power level,
it gives an power closest to the standard.
This parameter is also used for MS cell selection and re-selection,
involved in the calculation of C1 and C2 values. If this parameter value
is too high, the MS close to BTS will interfere with the adjacent channel;
if the value is too low, the success rate of MS access at the edge of
cell will be low.
The setting for this parameter should follow this principle: guarantee a

Description

certain success rate of MS access at the cell edge while decreasing the
4-430

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

access level of MS as much as possible. Obviously, the coverage area


increases with the uplift of MS output power. It is recommended to set
this parameter 5 (for GSM900MS) and 2 (for GSM1800MS).
After the parameter is set, make a dial test at the cell boundary. Test the
success rate of MS access and access time under different parameter
settings to determine whether to increase or decrease the value of the
parameter.
For the parameter value, see the appendix.
This parameter indicates the parameter used during re-selection in
transmission state.
Managed Object

Cell
0..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter should be set on demand of radio environment.


The setting for this parameter should follow this principle: guarantee a

Configuration Rule and


Adjustment Suggestion

certain success rate of MS access at the cell edge while decreasing the
access level of MS as much as possible. Obviously, the coverage area
increases with the uplift of MS output power. It is recommended to set
this parameter 5 (for GSM900MS) and 2 (for GSM1800MS).

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Reselection
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-431
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.18.30 LSA ID (LSA_Id)


Full Name

LSA ID

Abbreviation

LSA_Id

3GPP Name

LSA ID

3GPP Reference

3GPP TS 45.008 V5.22.0


The LSA ID is broadcast to the MS in the SI4 message on the BCCH
channel. This parameter indicates the LSA ID of the cell.SoLSA (Support
of Localised Service Area) is the local serving area consisting of a cell or

Description

a series of cells. The coverage of these cells can be discontinuous.

Managed Object

Cell
0.. 16777215

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is related to PBCCH. The default value is kept.

Configuration Rule and


Adjustment Suggestion

This parameter is related to PBCCH, and the default value is not used.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-432
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.18.31 LSA Offset (LSA_Offset)


Full Name

LSA Offset

Abbreviation

LSA_Offset

3GPP Name

LSA_OFFSET

3GPP Reference

TS45.008: "Radio subsystem link control"


This parameter is broadcast to the MS through the SI4, SI6 and SI7 messages. It is an offset value that will be used when the MS is informed of
LSA reselection between two cells with the same LSA priority. For the
description about the parameter LSA_OFFSET, refer to the protocol TS

Description

45.008.

Managed Object

Cell

Value Range and Step

0, 4, 8, 16, 24, 32, 48, 64

Unit

None

Default Value

Default Value
Configuration Reason

The LSA services are not supported.

Configuration Rule and


Adjustment Suggestion

The LSA services are not supported.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-433
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.19 GPRS Channel Parameters


4.19.1 PAGCH reserved blocks (PagBlkRes)
Full Name

PAGCH reserved blocks

Abbreviation

PagBlkRes

3GPP Name

BS_PAG_BLKS_RES

3GPP Reference

TS45.002: "Multiplexing and multiple access on the radio path"


This parameter is used at the MS side. It belongs to the PCCCH
organization parameters, and is broadcast to the MS in the PSI1
message.
This parameter indicates the number of blocks where neither packet
paging nor PBCCH can appear in a 52-frame multiframe.On these
blocks, only PAGCH, PDTCH and PACCH can appear. The "UPLINK
ASSIGNMENT" message will be sent preferentially on these fixed blocks
to speed up the establishment of the uplink TBF.
After sending the channel request on the PRACH channel, the MS waits
for the uplink assignment message on all PCCCH channels of the same

Description

timeslot as the PRACH channel.

Managed Object

Cell
0..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value is dependent upon the value stipulated in the protocol,

Configuration Reason

and the traffic model in the network.

Configuration Rule and

This value is dependent upon the value stipulated in the protocol, and

Adjustment Suggestion

the traffic model in the network.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-434
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.2 PBCCH reserved blocks (PbcchBlks)


Full Name

PBCCH reserved blocks

Abbreviation

PbcchBlks

3GPP Name

BS_PBCCH_BLKS

3GPP Reference

TS45.003: "Multiplexing and multiple access on the radio path"


This parameter is used at the MS side. It belongs to the PCCCH
structure parameters, and is broadcast to the MS in the PSI1 message.
This parameter indicates the number of blocks assigned as PBCCH in
a 52-frame multiframe (altogether 12 blocks).
PBCCH blocks are used simultaneously by the packet system messages
sent at a high rate and a low rate. The message that is sent at a high
rate has higher priority. This parameter must be configured together with
the PSI1_REPEAT_PERIOD parameter in the PSI1 message to ensure
that the block resources are available for the packet system messages,

Description

sent both at high and low rates.

Managed Object

Cell
PBCCH occupies 1 block in the multiframe
PBCCH occupies 2 blocks in the multiframe
PBCCH occupies 3 blocks in the multiframe

Value Range and Step

PBCCH occupies 4 blocks in the multiframe

Unit

None

Default Value

PBCCH occupies 4 blocks in the multiframe.

Default Value

The default value is dependent upon the value stipulated in the protocol,

Configuration Reason

and the traffic model in the network.

Configuration Rule and

This value value is dependent upon the value stipulated in the protocol,

Adjustment Suggestion

and the traffic model in the network.

Change Mode

Offline

Related features

None

Related Parameters

None

4-435
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.3 PRACH reserved blocks (PrachBlks)


Full Name

PRACH reserved blocks

Abbreviation

PrachBlks

3GPP Name

BS_PRACH_BLKS

3GPP Reference

TS45.004: "Multiplexing and multiple access on the radio path"


This parameter is used at the MS side. It belongs to the PCCCH
organization parameters, and is broadcast to the MS in the PSI1
message. This parameter indicates the number of fixed blocks reserved
for the PRACH channel in the PDCH channel that bears PCCCH.
These blocks should be identified by "USF = FREE". The MS can use

Description

this parameter or USF = FREE to carry out the PRACH assignment.

Managed Object

Cell
0..15

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The defalut value is dependent upon the value stipulated in the protocol,

Configuration Reason

and the traffic model in the network.

Configuration Rule and

This value is dependent upon the value stipulated in the protocol, and

Adjustment Suggestion

the traffic model in the network.

Change Mode

Offline

Related features

None

Related Parameters

None

4-436
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.4 Interval range of packet access attempt (TxInt)


Full Name

Interval range of packet access attempt

Abbreviation

TxInt

3GPP Name

TX_INT

3GPP Reference

3GPP TS44.060 V5.19.0


This parameter is used at the MS side. It belongs to the PRACH control
parameters, and is broadcast to the MS in the PSI1 message. When
establishing a connection, the MS sends the channel request message
in the PRACH channel to the network.
PRACH is an ALOHA channel, so the network allows the MS to send
multiple channel request messages before it receives the packet
assignment message, to improve the success rate of MS access. If
the MS does not get any response for the previous channel request
message, it can resend a channel request message after waiting for a
random period. The parameter TxInt (interval range of packet access
attempt) is used to determine the time length of random waiting and is
the number of delay timeslot randomly connected.
The random access time is determined by the interval range of packet
access attempt (TxInt) and the interval period of packet access attempt

Description

(S).

Managed Object

Cell

Value Range and Step

2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 20, 25, 32, 50

Unit

None

Default Value

32

4-437
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

This parameter is related to PBCCH. The default value is reserved.

Configuration Rule and

This parameter is related to PBCCH. It is recommended not to adjust

Adjustment Suggestion

the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.5 Interval period of packet access attempt (S)


Full Name

Interval period of packet access attempt

Abbreviation

3GPP Name

3GPP Reference

3GPP TS44.060 V5.19.0


This parameter is used at the MS side.
It belongs to the PRACH control parameters, and is broadcast to the MS
in the PSI1 message.When establishing a connection, the MS sends the
channel request message in the PRACH channel to the network.
PRACH is an ALOHA channel, so the network allows the MS to send
multiple channel request messages before it receives the packet
assignment message, to improve the success rate of MS access. If
the MS does not get any response for the previous channel request
message, it can resend a channel request message after waiting for a
random period. The parameter S is used to decide the time length of
random waiting and to calculate the minimum timeslot number between

Description

two channel requests.

4-438
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

The random access time is determined by the interval range of packet


access attempt (TxInt) and the interval period of packet access attempt
(S).
Managed Object

Cell

Value Range and Step

12, 15, 20, 30, 41, 55, 76, 109, 163, 217

Unit

Default Value

109

Default Value
Configuration Reason

This parameter is related to PBCCH. The default value is reserved.

Configuration Rule and

This parameter is related to PBCCH. It is recommended not to adjust

Adjustment Suggestion

the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.6 MAX Times of Attempt (MaxRetrans)


Full Name

MAX Times of Attempt

Abbreviation

MaxRetrans

3GPP Name

MAX_RETRANS

3GPP Reference

3GPP TS44.060 V5.19.0

4-439
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is used at the MS side. It belongs to the PRACH control


parameters, and is broadcast to the MS in the PSI1 message, indicating
the maximum attempts of random access allowed on PRACH for the
MSs with radio priority 1..4.
This parameter is an array with 4 elements. The first array element
corresponds to the maximum number of attempts allowed for radio
Description

priority 1, and so on.

Managed Object

Cell

Value Range and Step

1, 2, 4, 7

Unit

None

Default Value

[4, 4, 4, 4]

Default Value
Configuration Reason

This parameter is related to PBCCH. The default value is reserved.

Configuration Rule and

This parameter is related to PBCCH. It is recommended not to adjust

Adjustment Suggestion

the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.7 Access control level (AccCtrlClass)


Full Name

Access control level

Abbreviation

AccCtrlClass

3GPP Name

ACC_CONTR_CLASS

3GPP Reference

3GPP TS44.060 V5.19.0


4-440

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter indicates the access control level of the MS allowed to


visit the cell. In the GSM system, each MS has an access level (15
levels in total), 0..9 for common MS, 11..15 for special MS has the level,
and the level 10 does not exist. The system can prohibit the MS with
some access level to access the cell. For convenient programming,
C10 is always 0.
If the Nth bit of THE access control level is 0 (0 represents access
allowed, 1 represents access not allowed), the MS with access control
level =N (N=0, 1, ... 9, 11, ... 15) is allowed to access.Bit 11= EC
indicates that emergency call is allowed.
This parameter consists of two bytes (16 bits).
The first bit: C15, C14, C13, C12, C11, C10, C9, C8;
The second bit: C7, C6, C5, C4, C3, C2, C1, C0
When Cn is 0, the MS with the access level N (N= 0..9, 11..15) is
allowed to access.
When Cn is 1, the MS with the access level N (N= 0..9, 11..15) is not
allowed to access the cell.
Description

C10 is always 0.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

[No, No, No, No, No, No, No, No, No, No, No, No, No, No, No, No]

Default Value
Configuration Reason

This parameter is related to PBCCH. The default value is reserved.

Configuration Rule and

This parameter is related to PBCCH. It is recommended not to adjust

Adjustment Suggestion

the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

4-441
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

4.19.8 Access Persistent Level (PersistLev)


Full Name

Access Persistent Level

Abbreviation

PersistLev

3GPP Name

PERSISTENCE_LEVEL

3GPP Reference

3GPP TS44.060 V5.19.0


This parameter is used at the MS side. It belongs to the PRACH control
parameters, and is broadcast to the MS in the PSI1 message, The
network sets a level threshold P i (i = 1, 2, 3, 4) for the MS of various
radio priorities.
For each attempt of packet access, the MS abstracts a random value
R with even distribution probability from the set {0, 1... 15}. The MS is
allowed to initiate an attempt of packet access only when P i is
lower than or equal to R.
This parameter is an array with 4 elements. The first element

Description

corresponds to the access persist level of radio priority 1, and so on.

Managed Object

Cell

Value Range and Step

0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16

Unit

None

Default Value

[0, 0, 0, 0]

Default Value
Configuration Reason

Generally, all MSs are allowed to access.

Configuration Rule and


Adjustment Suggestion

Currently, the usage of PBCCH is not needed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

4-442
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.9 Subscriber occupying other preference channel support


(HybridOccuSupp)
Full Name

Subscriber occupying other preference channel support

Abbreviation

HybridOccuSupp

3GPP Name

None

3GPP Reference

None
The attribute PreferPsService of the static PD channels and dynamic
channels falls into such two types as GPRS and EGPRS.
This parameter indicates whether to support GPRS users occupying
EGPRS preference channel and whether EDGE users can occupy

Description

GPRS preference channel.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Yes

Default Value

GPRS users can occupy EDGE preference channel by default.

Configuration Reason

EDGE users can occupy GPRS preference channel by default.


The value is set as "No", to ensure the access rate of EDGE users and

Configuration Rule and


Adjustment Suggestion

to prevent the GPRS users from interfering the rate of EDGE users. If
the radio resources are limited, to a certain extent, the rate is allowed
to be decreased, and set the value as "Yes" to allow the EGPRS users,
together with the EDGE users, occupy the preference channel.

Change Mode

Offline

Related features

ZGO-03-02-009 Flexible Priority Handling of Packet Data Channel

Related Parameters

[Ts]PreferPsService

Relationship
Related Interfaces

This parameter is valid only when the attribute PreferPsService of the


channel is configured as GPRS preferred or EDGE preferred.
Um

4-443
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.10 PS subscriber moving out of other preference channel


support (AllowPsMove)
Full Name

PS subscriber moving out of other preference channel support

Abbreviation

AllowPsMove

3GPP Name

None

3GPP Reference

None
This parameter describes whether to support subscriber moving out of
other preference channel.
If the EDGE users on other channels are released, the EDGE users on
the GPRS preference channel wll be attempted to be migrated.
If the EDGE users on other channels are released, the EDGE users on

Description

the GPRS preference channel wll be attempted to be migrated.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is not enabled at the suggestion.

Configuration Rule and


Adjustment Suggestion

This is a special functional switch, which is not enabled at the suggestion.

Change Mode

Offline

Related features

ZGO-03-02-009 Flexible Priority Handling of Packet Data Channel

Related Parameters

None

Relationship

None

Related Interfaces

Um
4-444

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.11 CS subscriber moving support (AllowCsMove)


Full Name

CS subscriber moving support

Abbreviation

AllowCsMove

3GPP Name

None

3GPP Reference

None
This parameter describes whether to support CS service (on the dynamic
channel) moving in the cell when the CS channel is released and the
resources are relatively idle, so as to enhance the continuity of PS timeslot
combination to the maximum extent. The resources are idle, which is
based on: all idle CS service channels (including the static and dynamic
TCHs)/total number of available service channels = alarm threshold of

Description

channel resources in the cell (ResLimit[3]).

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


This function can be enabled when radio resources are comparatively
sufficient, so as to ensure the maximum continuity of the PS channel
and the rate of PS service.

Change Mode

Offline

Related features

ZGO-03-02-009 Flexible Priority Handling of Packet Data Channel

Related Parameters

None

Relationship

None

4-445
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.12 Threshold of GPRS/GPRS,EDGE/EDGE service moving


(SfPreferBusyThs)
Full Name

Threshold of GPRS/GPRS,EDGE/EDGE service moving

Abbreviation

SfPreferBusyThs

3GPP Name

None

3GPP Reference

None
During this PS application, the allocation result is optimal if the existing
QoS quota / total available QoS quota on the preferential channel (GPRS
or EDGE) at this side is lower than this percentage. The allocation
result, together with the congeneric occupied threshold, is used to the
target evaluation function.
If the AllowPsMove switch is enabled, the GPRS users on the GPRS
preference channel are attempted to be migrated after they are released.
If the number of GPRS users on the EDGE preference channel
exceeds the non-congeneric occupied threshold (OpPreferBusyThs), PS
migration is initiated when the congeneric threshold (SfPreferBusyThs)
on the GPRS channel is lower than the threshold after the migration of
GPRS users. The same as EDGE.
If the EDGE users on other channels are released, the EDGE users on

Description

the GPRS preference channel wll be attempted to be migrated.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

100

4-446
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value

It is recommended not to adjust the default value but set it as 100 (that

Configuration Reason

is, this parameter is invalid).


It is recommended not to adjust the value but set it as 100 (that is, this
parameter is invalid).
This parameter is valid until the GPRS preference channel and EDGE
preference channel are set.
When the idle channels are unavailable, the GPRS users can be
allocated to the non-congeneric preference channel, to prevent the
GPRS users and EDGE users from multiplexing channels, which

Configuration Rule and

influences the user rate.

Adjustment Suggestion

If the value is 100%, it prevents the GPRS users and EDGE users from
multiplexing channels, thereby relative index of EDGE user throughput
can be improved.
It is recommended to adjust the value as 80 if the proportion of the
GPRS users to the EDGE users in the cell fluctuates greatly.
: GPRSEDGE
.You can adjust the value if the GPRS and EDGE preference
channels are inadequate.

Change Mode

Offline

Related features

ZGO-03-02-009 Flexible Priority Handling of Packet Data Channel

Related Parameters

[Cell]AllowPsMove
[Cell]OpPreferBusyThs

Relationship

This parameter, which should be used with the parameter


SfPreferBusyThs, is valid until the AllowPsMove switch is enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.13 Threshold of GPRS/EDGE service moving


(OpPreferBusyThs)
Full Name

Threshold of GPRS/EDGE service moving


4-447

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

OpPreferBusyThs

3GPP Name

None

3GPP Reference

None
During this application, the allocation result is optimal if the existing
QoS quota / total available QoS quota on the preferential channel at
the oppsite side is lower than this percentage. The allocation result,
together with the congeneric occupied threshold, is used to the target
evaluation function.
If the AllowPsMove switch is enabled, the GPRS users on the GPRS
preference channel are attempted to be migrated after they are released.
If the number of GPRS users on the EDGE preference channel
exceeds the non-congeneric occupied threshold (OpPreferBusyThs), PS
migration is initiated when the congeneric threshold (SfPreferBusyThs)
on the GPRS channel is lower than the threshold after the migration of
GPRS users. The same as EDGE.
If the EDGE users on other channels are released, the EDGE users on

Description

the GPRS preference channel wll be attempted to be migrated.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended not to adjust the default value but set it as 0 (that is,

Configuration Reason

this parameter is invalid).

Configuration Rule and

It is recommended not to adjust the value but set it as 0 (that is, this

Adjustment Suggestion

parameter is invalid).

Change Mode

Offline

Related features

ZGO-03-02-009 Flexible Priority Handling of Packet Data Channel

Related Parameters

[Cell]AllowPsMove
[Ts]PDCHPrecedence
[Cell]SfPreferBusyThs

Relationship

This parameter, which should be used with the parameter


SfPreferBusyThs, is valid until the AllowPsMove switch is enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

4-448
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.14 PS channel expand (Info1_1_18)


Full Name

PS channel expand

Abbreviation

Info1_1_18

3GPP Name

None

3GPP Reference

None
This parameter indicates whether PS channel extension is supported.
For example, if the current number of channels that are used by MS
is 2+1 while the MS is allowed to use more time slots, the number of
channels can be increase to 3+1 or 4+1 after the adjacent CS channels

Description

are released.

Managed Object

Cell
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

0: No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a switch for a special function. The switch is disabled by default.


If there are many cases that the CS services grab the PS service
channels, this function can be enabled. .
This function can resume more radio channels for PS services.

Change Mode

Offline

Related features

ZGO-03-02-012 PS Channel Extension

Related Parameters

[Cell]Info1_1_24

Relationship

Set the switch of channel extension to "Yes", and the TCH channel
threshold will be effective during PS channel extension.

Related Interfaces

None

Impact on Equipment

Impact on service

4-449
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.15 Idle TCH threshold for PS channel expand (Info1_1_24)


Full Name

Idle TCH threshold for PS channel expand

Abbreviation

Info1_1_24

3GPP Name

None

3GPP Reference

None
When the proportion of TCH channel in a cell is higher than this threshold, PS channel extension will be conducted. The proportion of idle TCH
channels in a cell is the ratio of the sum of idle TCH/F channels and TCH/H
channels (two TCH/H channels are regarded as one TCH/F) to the num-

Description

ber of all the available service channels in a cell.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

Default Value

20

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Low threshold is good for PS channel extension.


Low threshold is good for the start of PS channel extension that starts
when there are more CS services. High threshold will delay the start PS
channel extension that starts when there are less CS services.

Change Mode

Offline

Related features

ZGO-03-02-012 PS Channel Extension

Related Parameters

[Cell]Info1_1_18

Relationship

Set the switch of channel extension to "Yes", and the TCH channel
threshold will be effective during PS channel extension.

Related Interfaces

None

Impact on Equipment

4-450
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.16 Maximum PS uplink user per ts (MaxPsUserPerTs_0)


Full Name

Maximum PS uplink user per ts

Abbreviation

MaxPsUserPerTs_0

3GPP Name

None

3GPP Reference

None
This parameter describes the maximum number of PS uplink users
allowed by a single timeslot.
If the packet traffic is large on site, hardware load is high, and capacity
expansion is impossible temporally, the user can modify this parameter
to reduce the number of uplink packet users supported by the channel.
In this way, the packet traffic volume is reduced indirectly, which helps
reduce the hardware load.
If this value is reduced, the KPI index of the packet service, such as

Description

downlink TBF link success rate, is reduced indirectly.

Managed Object

Cell
1..7

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value 4 ensures to balance the channel congestion rate

Configuration Reason

and resource utilization rate.


If the value is small, it causes radio resources congestion when the data
traffic is busy, thereby the uplink TBF establishment success rate is

Configuration Rule and

influenced.

Adjustment Suggestion

If the value is large, PDTCH supported by users is not limited manually,


but users' feeling may be influenced because the PDTCH is multiplexed
too much.

Change Mode

Offline

4-451
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.17 Max PS downlink user per TS (MaxPsUserPerTs_1)


Full Name

Max PS downlink user per TS

Abbreviation

MaxPsUserPerTs_1

3GPP Name

None

3GPP Reference

None
This parameter describes the maximum number of PS downlink users
allowed by a single timeslot.
The PS with a single TS supports a maximum of 16 users at downlink.
The traffic is proper, and the default value is 6. The traffic can be
adjusted in accordance with the traffic. If this value is reduced, the KPI
index of the packet service, such as downlink TBF link success rate, is
reduced indirectly. If the downlink TBF link setup success rate of packet
services is low and the packet channel resources can satisfy users'

Description

requirement, a high value is recommended.

Managed Object

Cell
1..16

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value 6 ensures to balance the channel congestion rate

Configuration Reason

and resource utilization rate.

4-452
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

If the value is small, it causes radio resources congestion when the data
traffic is busy, thereby the uplink TBF establishment success rate is
Configuration Rule and

influenced.

Adjustment Suggestion

If the value is large, PDTCH supported by users is not limited manually,


but users' feeling may be influenced because the PDTCH is multiplexed
too much.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.19.18 Support dynamic channel move (DynChMove)


Full Name

Support dynamic channel move

Abbreviation

DynChMove

3GPP Name

None

3GPP Reference

None
A dynamic channel can be used for both the voice service and the PS
data service. For the cells configured with static TCH channels and dynamic channels, the CS voice service is already prior to use static TCH
channels but occupies dynamic channels as the voice service increases.
This parameter determines whether to support the function of channel
adjustment. This function releases the CS service that occupies dynamic

Description

PDCH channels and switches the service to the static TCH channel.

Managed Object

Cell
0: No

Value Range and Step

1: Yes
4-453

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.


For the cells configured with both dynamic channels and static channels,

Configuration Rule and

it is recommended that this function be enabled. After that, the number

Adjustment Suggestion

of channels available for the PS service increases and the handover


times in the cell increase.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.19.19 Idle static TCH THS for dynamic channel move


(IdleTCHForDChMove,%)
Full Name

Idle static TCH THS for dynamic channel move

Abbreviation

(IdleTCHForDChMove,%)

3GPP Name

None

3GPP Reference

None
If the proportion of idle static TCH channels in a cell to all the available service channels is higher than this threshold, the CS service that occupies

Description

the dynamic PDCH channel can be switched to the static TCH channel.

Managed Object

Cell

Value Range and Step

0..100

Unit

%
4-454

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value

20

Default Value

If this threshold is configured too low, it is easier to migrate the CS

Configuration Reason

service on the dynamic channel to the static channel.

Configuration Rule and


Adjustment Suggestion

This parameter determines the start threshold of dynamic channel


migration. Adjusting this threshold will increase or decrease the
frequency of dynamic channel migration accordingly.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.19.20 PS channel alloc reduction support (SuppReducePd)


Full Name

PS channel alloc reduction support

Abbreviation

SuppReducePd

3GPP Name

None

3GPP Reference

None
The parameter determines whether the cell supports reducing the number

Description

of PDTCH in use based on the PDTCH load.

Managed Object

CELL
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

Not a basic function, disabled by default.


4-455

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

To increase the number of accessed mobile phones and reduce the


error ratio of TBF establishment in case of high traffic load in a cell,
enable the feature.

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

4.19.21 Initial limit threshold of PDTCH alloc (LmtThreshold_0)


Full Name

Initial limit threshold of PDTCH alloc

Abbreviation

LmtThreshold_0

3GPP Name

None

3GPP Reference

None
The parameter is the initial limit on the number of PDTCH. When the channel load meets the condition: initial limit<= channel load < medium limit,

Description

one channel can be reduced.

Managed Object

CELL
65..74

Value Range and Step

step: 1

Unit

None

Default Value

70

Default Value

Enable the initial limit on channel distribution when the traffic reaches a

Configuration Reason

certain volume.

Configuration Rule and


Adjustment Suggestion

The larger the value, the higher the initial limit is.

4-456
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

4.19.22 Medium limit threshold of PDTCH alloc (LmtThreshold_1)


Full Name

Medium limit threshold of PDTCH alloc

Abbreviation

LmtThreshold_1

3GPP Name

None

3GPP Reference

None
The parameter is the medium limit on the number of PDTCH. When the
channel load meets the condition: medium limit<= channel load < Maxi-

Description

mum limit, two channels can be reduced.

Managed Object

CELL
75..84

Value Range and Step

step: 1

Unit

None

Default Value

80

Default Value

Enable the medium limit on channel distribution when the traffic reaches

Configuration Reason

a higher volume.

Configuration Rule and


Adjustment Suggestion

The larger the value, the higher the medium limit is.

Change Mode

Offline

Related features

Null

Related Parameters

Null
4-457

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

4.19.23 Maximum limit threshold of PDTCH alloc (LmtThreshold_2)


Full Name

Maximum limit threshold of PDTCH alloc

Abbreviation

LmtThreshold_2

3GPP Name

Null

3GPP Reference

Null
The parameter is the maximum limit on the number of PDTCH. When the

Description

channel load is greater this limit, four channels can be reduced.

Managed Object

CELL
85..94

Value Range and Step

step: 1

Unit

None

Default Value

90

Default Value

Enable the maximum limit on channel distribution when the traffic is

Configuration Reason

very high.

Configuration Rule and


Adjustment Suggestion

The larger the value, the higher the maximum limit is.

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

4-458
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

4.19.24 Damping of PDTCH alloc from limit to non-limit


(LmtThreshold_3)
Full Name

Damping of PDTCH alloc from limit to non-limit

Abbreviation

LmtThreshold_3

3GPP Name

Null

3GPP Reference

Null
This parameter is used to avoid frequent changes between limited chan-

Description

nel allocation and unlimited channel allocation.

Managed Object

CELL
0..15

Value Range and Step

step: 1

Unit

None

Default Value

Default Value

Reduce frequent changes between limited channel allocation and

Configuration Reason

unlimited channel allocation.


The smaller the parameter value, the more probable the traffic is subject

Configuration Rule and


Adjustment Suggestion

to changes between limited channel allocation and unlimited allocation.


The larger the value, the less probable the traffic is subject to such
changes, but the sensibility to channel load changes is reduced.

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

0
4-459

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN
OMC Access Path

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Channel

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

4.20 PS Handover Parameters


4.20.1 PS handover support (HandoverSupp)
Full Name

PS handover support

Abbreviation

HandoverSupp

3GPP Name

Internal

3GPP Reference

None
This parameter describes whether the cell supports MS to perform PS

Description

handover.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]RlcStateReset
[Cell]EnablePCCNTrigHO

Relationship

The service function parameters used by the PS handover are valid until
this parameter is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

4-460
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.20.2 ACK of PS handover command (HOCommandAck)


Full Name

ACK of PS handover command

Abbreviation

HOCommandAck

3GPP Name

None

3GPP Reference

None
This parameter describes whether PS HANDOVER COMMAND requires

Description

acknowledgement.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

4-461
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.20.3 Blind transmission support (BlindTransSupp)


Full Name

Blind transmission support

Abbreviation

BlindTransSupp

3GPP Name

Blind Transmission

3GPP Reference

3GPP TS 43.129
This parameter describes whether the cell supports blind transmission.
The blind transmission means the target cell begins to transmit downlink

Description

data before the MS accesses to the cell.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

4-462
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.20.4 Optimised handover support (OptimizeHOSupp)


Full Name

Optimised handover support

Abbreviation

OptimizeHOSupp

3GPP Name

None

3GPP Reference

None
This parameter describes whether the optimized handover is supported
in the cell that supports PS handover.
If the optimized handover is allowed, it is necessary to decide whether
the serving cell and the target cell have the same NSE and RA. If they
have the same NSE and RA, and relevant QoS information (including
PFI, PFT, ABQP, and AR) is obtained, perform optimized handover.

Description

Otherwise, perform normal handover.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

This is a special functional switch, which is enabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

4-463
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.20.5 Send handover access in synchronised handover


(SendAccessSync)
Full Name

Send handover access in synchronised handover

Abbreviation

SendAccessSync

3GPP Name

PS Handover Access

3GPP Reference

3GPP TS 43.129
This parameter indicates whether the handover message should be sent
during synchronization handover.After the MS receives the PS handover
message, it performs handover to the channel allocated in the new cell.
For example, if the PS HANDOVER COMMAND message carries Handover Reference, the MS will send the PS HANDOVER ACCESS mes-

Description

sage to BSS.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

4-464
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.20.6 Send handover access in pre-synchronised handover


(SendAccessPreSync)
Full Name

Send handover access in pre-synchronised handover

Abbreviation

SendAccessPreSync

3GPP Name

PS Handover Access

3GPP Reference

3GPP TS 43.129
This parameter describes whether the PS HANDOVERACCESS message should be sent during the pre-synchronization handover.After the
MS receives the PS handover message, it performs handover to the channel allocated in the new cell. For example, if the PS HANDOVER COMMAND message carries Handover Reference, the MS will send the PS

Description

HANDOVER ACCESS message to BSS.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

4-465
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.20.7 Reset RLC (RlcStateReset)


Full Name

Reset RLC

Abbreviation

RlcStateReset

3GPP Name

RLC_RESET

3GPP Reference

3GPP TS 44.060
This parameter indicates whether the state of RLC should be reset. That
is, the related variables of the RLC layer entity keep the same when the

Description

MS performs handover from the source cell to the target cell.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

If the PS handover is not supported, hold the RLC state.

Configuration Rule and

Currently, this parameter is displayed only and does not need to be

Adjustment Suggestion

adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None
4-466

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.20.8 Trigger PS handover by PCCN (EnablePCCNTrigHO)


Full Name

Trigger PS handover by PCCN

Abbreviation

EnablePCCNTrigHO

3GPP Name

Internal

3GPP Reference

None
This parameter describes whether to use PCCN to trigger PS handover.
That is, BSC makes PS handover decison when it receives PCCN (Packet

Description

Cell Change Notification) transmitted by MS.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value

BSCcan make handover decision when it receives measurement report

Configuration Reason

or PCCN message, so as to perform handover as soon as possible.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

4-467
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.20.9 Early get system information in intra-BSS handover


(EarlyGetSysIntra)
Full Name

Early get system information in intra-BSS handover

Abbreviation

EarlyGetSysIntra

3GPP Name

None

3GPP Reference

None
This parameter describes whether to obtain the system information of ad-

Description

jacent cell in advance during intra-BSS handover.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

4-468
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.21 EDGE Parameters


4.21.1 Max number of GTTP lapdm frame (GttpLapdmNum)
Full Name

Max number of GTTP lapdm frame

Abbreviation

GttpLapdmNum

3GPP Name

MAX_LAPDm

3GPP Reference

3GPP TS 44.018 V5.22.0


This parameter indicates the maximum number of GTTP Lapdm frames.
It specifies the maximum number of Lapdm frames of GPRS signalling
message transmitted on the main DCCH.If MS and the network side support DYM, MS is in the dedicated mode, and MS or the network side needs
to transparently transmit the upper layer information at the Um interface,
use GPRS transparent procedure on the main DCCH when: 1, the information to transmit is GPRS signalling; 2, length of the GTTP message is

Description

smaller than the setting value of this parameter.

Managed Object

Cell

Value Range and Step

0...7

Unit

None

Default Value

Default Value

The default value 3 is enough for transmitting such GMM signalling

Configuration Reason

services as RAU and ATTACH.

4-469
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The larger the value is, the longer the GPRS signalling is carried, and
the more the LAPDm channel is influenced.Usually, GPRS signalling is
Configuration Rule and
Adjustment Suggestion

not long, so it is suggested to set the value to an appropriate value. If


the value is too large, user experience of voice services will be slightly
influenced.If signalling transmission cannot reach the maximum number
of GTTP Lapdm frames, use the transmission mode of setting up TBF in
the dedicated mode.

Change Mode

Offline

Related features

ZGO-01-03-005 Dual Transfer Mode

Related Parameters

[Cell]DTMSupport

Relationship

GttpLapdmNum is valid after the DTMSupport function is enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.21.2 EGPRS packet channel request access program support


(EgprsPacketChreq)
Full Name

EGPRS packet channel request access program support

Abbreviation

EgprsPacketChreq

3GPP Name

EGPRS_PACKET_CHANNEL_REQUEST

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter information is broadcast to the MS in GRPS CELL OPTIONS of SI13, PSI1 and PSI13. It indicates if the cell supports EGPRS_PACKET_CHANNEL_REQUEST access flow. If the cell supports
EGPRS and this flow, the EGPRS terminal is able to originate EGPRS

Description

packet access flow on RACH or PRACH (if PBCCH exists).

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

4-470
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Unit

None

Default Value

No

Default Value

The system default uses forcible two phase access, so this function

Configuration Reason

is not enabled.

Configuration Rule and


Adjustment Suggestion

The network side hopes MS adopts one phase access to enable


this function. For the cell without forcible two phase access, the MS
supporting EGPRS will trigger one-phase access procedure.

Change Mode

Offline

Related features

ZGO-03-05-003 EGPRS Packet Channel Request on CCCH

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.21.3 Uplink LA+IR quality control support (IrSupportUp)


Full Name

Uplink LA+IR quality control support

Abbreviation

IrSupportUp

3GPP Name

RESEGMENT

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter indicates whether the cell supports "uplink IR quality control".If it supports, the network could set the RESEGMENT in
PACKET UPLINK ACK/NACK, PACKET UPLINK ASSIGNMENT and
PACK TIMESLOT RECONFIGURE message as FALSE to inform MS
system of using IR quality control mode, and MS uplink retransmission

Description

could not be segmented.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No
4-471

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

If this switch is enabled, the uplink throughput can be improved, and MS

Adjustment Suggestion

uplink retransmission is not segmented but occupies BTS memory.

Change Mode

Offline

Related features

ZGO-03-05-006 Incremental Redundancy in UL

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

ZGO-03-05-002 EGPRS Link Adaptation

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.21.4 Take Preemptive transmit bit function (PreemptivetRans)


Full Name

Take Preemptive transmit bit function

Abbreviation

PreemptivetRans

3GPP Name

PRE_EMPTIVE_TRANSMISSION

3GPP Reference

3GPP TS 44.060 V5.19.0

4-472
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter indicates whether the cell employs the "PreemptivetRans


bit" function. If the cell supports that function, network indicates MS
whether to send the RLC data of PENDING-ACK when there is no
data in NACK status and no new RLC data block to be transmitted or
the transmission window is full by PRE_EMPTIVE_TRANSMISSION in
PACKET UPLINK ACK/NACK message.
The values are as follows:
Yes: Use preemptive transmission. MS should not send the data block
in PENDING-ACK status. But for the last piece of current TBF, even if its
status is PENDING ACK, it should be transmitted.
No: Do not use preemptive transmission. MS should send the oldest
data in PENDING-ACK status, then the second oldest data.If all data in
Description

PENDING-ACK status have been sent, repeat from the oldest one.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


If the cell supports that function, network indicates MS whether to send
the RLC data of PENDING-ACK when there is no data in NACK status

Configuration Rule and

and no new RLC data block to be transmitted or the transmission

Adjustment Suggestion

window is full by PRE_EMPTIVE_TRANSMISSION in PACKET UPLINK


ACK/NACK message.Enabling the preemptive transmit function can
improve throughput to a certain extent.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

4-473
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

4.21.5 Average filter period for uplink BEP (BEPperiodUp)


Full Name

Average filter period for uplink BEP

Abbreviation

BEPperiodUp

3GPP Name

BEP_PERIOD

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is the internal parameter of PCU. The meaning of this
parameter is the same as BEPPeriodDown, but it is to calculate the uplink

Description

measurement data inside of PCU.

Managed Object

Cell

Value Range and Step

0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15

Unit

None

Default Value

Default Value

The protocol recommends to set the forgetting factor to 0.4

Configuration Reason

corresponding to 4 of this parameter.


The relatively large value helps increase the weight of the previous
measurement report. Consequently, it brings a positive impact on the

Configuration Rule and

related index of throughput and the actual calculated BEP is more

Adjustment Suggestion

reliable.
The relatively small value helps adjust the coding mode when the radio
environment changes accidentally.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None
4-474

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

None

4.21.6 Average filter period for downlink BEP (BEPperiodDown)


Full Name

Average filter period for downlink BEP

Abbreviation

BEPperiodDown

3GPP Name

BEP_PERIOD

3GPP Reference

TS45.008: "Radio subsystem link control"


This parameter information is broadcast to the MS in the GPRS Cell
options of SI13, PSI1 and PSI13.In the EGPRS system, EGPRS MS
decides to report the MEAN_REP_AV (average error bit rate of the
radio block) and CV_BEP_AV (variance coefficient of radio block error
bit rate) under the whole TBF, or the measurement data per time slot
MEAN_BEP_TNx (0-7).
The protocol defines the calculation formula of these measurement data
(refer to 05.08 10.2.3.2.1). An oblivion factor is used in the formula and

Description

the value of the factor is defined by the average period of BEP filter.

Managed Object

Cell

Value Range and Step

0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10

Unit

None

Default Value

Default Value

The default value is dependent upon the value range defined in the

Configuration Reason

protocol, and the measurement interval.


The relatively large value helps increase the weight of the previous
measurement report. Consequently, it brings a positive impact on the

Configuration Rule and

related index of throughput and the actual calculated BEP is more

Adjustment Suggestion

reliable.
The relatively small value helps adjust the coding mode when the radio
environment changes accidentally.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

0
4-475

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.21.7 EGPRS phone quality measure mode (LinkQuameaMode)


Full Name

EGPRS phone quality measure mode

Abbreviation

LinkQuameaMode

3GPP Name

LINK_QUALITY_MEASUREMENT_MODE

3GPP Reference

3GPP TS 44.060 V5.19.0


This parameter defines EGPRS phone quality measure mode. It is
sent to MS in the PACKET DOWNLINK ASSIGNMENT or PACKET
TIMESLOT RECONFIGURE message.EGPRS measurement could
be performed based on each impulse, which is to measure by the
granularity of BURST. The feature of rapid EGPRS measurement
makes the network side be able to quickly respond the change of radio
environment, so as to choose the most proper coding mode and perform
power control.
This parameter is set in the measurement of EGPRS Timeslot Link
Quality Measurements IE. The following is the description of the
parameter values:
0: According to TB, MS reports MEAN-BEPinstead of I_LEVEL;
1: According to TB, , MS reports MEAN-BEP, and the obtained I_LEVEL
of 0-7 timeslot;
2: MS reports each MEAN-BEP with timeslot allocated, instead of
I_LEVEL;
3: MS reports each MEAN-BEP with timeslot allocated, and I_LEVEL

Description

with no more than 4 timeslots.

Managed Object

Cell

Value Range and Step

(0, 1, 2, 3)

Unit

None

Default Value

Default Value

Theoretically, setting of the default value is the best that MS reports

Configuration Reason

measurement performance according to timeslots.

4-476
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

If the value is 1, 2, or 3 and MS reports the performance according to


timeslot, wrong or missed reports may occur to some terminals, which
Configuration Rule and

influences the dynamic adjustment of coding scheme.

Adjustment Suggestion

It is more reasonable for MS to report in MEAN_BEP and CV_BEP


mode, so the proposed value is 0 and MS reports the performance
based on BTF because.

Change Mode

Offline

Related features

ZGO-03-05-002 EGPRS Link Adaptation

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.21.8 EDGE initial downlink allocation by multislot class1


(Info1_1_0)
Full Name

EDGE initial downlink allocation by multislot class1

Abbreviation

Info1_1_0

3GPP Name

None

3GPP Reference

None
This parameter indicates whether EDGE initial downlink allocation is
in accordance with multi-slot class 1.If it is, the initial allocation only
allocates one timeslot in accordance with multi-slot class 1; if it isn't, the
initial allocation allocates one or more timeslots in accordance with the
actual multi-slot capability.

Description

This parameter is employed after the version V6.20.21.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

4-477
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

No

Default Value
Configuration Reason

The default value is to ensure the service rate of small bust packages.

Configuration Rule and

If the PDCHs and Abis resources are enough, set the value as No; if the

Adjustment Suggestion

PDCHs and Abis resources are not enough, set the value as Yes.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.21.9 Use parameter of EGPRS Prior to GPRS' in Cell (Info1_7_5)


Full Name

Use parameter of EGPRS Prior to GPRS' in Cell

Abbreviation

Info1_7_5

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether to use the parameter of 'EGPRS Prior
to GPRS' in the cell. When the EGPRS prior to GPRS function is enabled
and this parameter is set to Yes, the cell-level allocating weights of EGPRS parameter is used. The number of blocks allocated to EGPRS and

Description

GPRS are adjusted according to a certain ratio.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

4-478
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value can be enabled as needed.


If it is necessary to set customized parameters for the cell, set this
parameter to 1; if the BSC-level parameters are used rather than the
customized parameters, set this parameter to 0.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]Info_4_6
[BSC]Info1_7_6
This parameter is valid until the Info_4_6 parameter is enabled; The

Relationship

Info1_7_6 parameter is valid until the Info_4_6 parameter and this


parameter are enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.21.10 Allocating weights of EGPRS (Info1_7_6)


Full Name

Allocating weights of EGPRS

Abbreviation

Info1_7_6

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the allocating weights of EGPRS for a
cell.When the EGPRS prior to GPRS function is enabled and this
parameter is set to Yes, the cell-level allocating weights of EGPRS
parameter is used. The number of blocks allocated to EGPRS and
GPRS are adjusted according to a certain ratio.
If the value is 0, the cell EGPRS service fails to get blocks. If the value is

Description

100, the cell GPRS service fails to get blocks.

4-479
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

70

Default Value

Setting of the default value is in consideration of the rate of EGPRS

Configuration Reason

and GPRS in the cell.


If it is necessary to set the customized parameters for the cell, enable
the setting of cell-level customized parameters.When EDGE and GPRS

Configuration Rule and


Adjustment Suggestion

share the same channel, this parameter value is larger, the EDGE user
gets more radio blocks and the EDGE service rate is higher. The smaller
this parameter value is, the less radio blocks the EDGE user gets, and
the lower the EDGE service rate is. This parameter acts on the dynamic
and static data service channels.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]Info_4_6
[BSC]Info_4_7
[BSC]Info1_7_5

Relationship

This parameter takes effect until the parameters Info_4_6 and Info1_7_5
are enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-480
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.21.11 EGPRS uplink init. Coding scheme/EGPRS


downlink init. Coding scheme/EGPRS uplink max.
coding schme/EGPRS downlink max. coding scheme
(EGPRSInitAttSelt_0~EGPRSInitAttSelt_3)
EGPRS uplink init.

Coding scheme/EGPRS downlink init.

scheme/EGPRS uplink max.

Coding

coding schme/EGPRS downlink max.

Full Name

coding scheme

Abbreviation

EGPRSInitAttSelt_0~EGPRSInitAttSelt_3

3GPP Name

None

3GPP Reference

None
This parameter indicates the initial coding scheme EGPRS subscribers
used. It is represented by a BYTE array, including EGPRS uplink initial
coding scheme, EGPRS downlink initial coding scheme, EGPRS uplink

Description

max coding scheme, and EGPRS downlink max coding scheme.

Managed Object

Cell

Value Range and Step

(MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7, MCS8, MCS9)

Unit

None

Default Value

(MCS6, MCS6, MCS9, MCS9)

Default Value

According to the general radio quality, MCS6 satisfies the data

Configuration Reason

transmission requirements.

Configuration Rule and


Adjustment Suggestion

If the cell radio quality is good, the initial coding scheme can be higher.

Change Mode

Offline

Related features

ZGO-03-05-002 Initial Coding Scheme per Cell Settable

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

4-481
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

4.21.12 EGPRS phones init. Code can be changed


(InitAttachExch_1)
Full Name

EGPRS phones init. Code can be changed

Abbreviation

InitAttachExch_1

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the coding method of EGPRS phones in
cell could be changed dynamically. The parameter bit1 indicates whether
the coding scheme of EGPRS phones is changed dynamically.0

Description

, 1.

Managed Object

Cell

Value Range and Step

1: 1: : Yes; 0: No

Unit

None

Default Value

Yes

Default Value

The default value is set in accordance with the adaptive coding scheme

Configuration Reason

of radio environment, so as to improve the packet transmission rate.

Configuration Rule and


Adjustment Suggestion

The value is better set to Yes in accordance with the adaptive coding
scheme of radio environment, so as to improve the packet transmission
rate.

Change Mode

Offline

Related features

ZGO-03-05-002 Initial Coding Scheme per Cell Settable

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

4-482
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

None

4.21.13 FANR in uplink TBF support (INFO1_4_0)


Full Name

FANR in uplink TBF support

Abbreviation

INFO1_4_0

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether FANR is supported by uplink TBF in
the cell.If the network and MS support FANR, the receiving information of
downlink radio blocks can be carried in uplink radio blocks and the network
can be timely informed of the receiving condition of downlink radio blocks,

Description

to accelerate retransmission of missed downlink radio blocks.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]INFO1_4_5
[BSC]Info_4_0
This parameter is valid until the Info_4_0 parameter is enabled; The

Relationship

INFO1_4_5 parameter is valid until the Info_4_0 parameter and this


parameter are enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None
4-483

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

4.21.14 FANR in downlink TBF support (INFO1_4_1)


Full Name

FANR in downlink TBF support

Abbreviation

INFO1_4_1

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether the downlink TBF in the cell supports
FANR.If the network and MS support FANR, the receiving information of
uplink radio blocks can be carried in downlink radio blocks and the network
can be timely informed of the receiving condition of uplink radio blocks, to

Description

accelerate retransmission of missed uplink radio blocks.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]INFO1_4_4
[BSC]Info_4_1
This parameter is valid until the Info_4_0 parameter is enabled; The

Relationship

INFO1_4_4 parameter is valid until the Info_4_0 parameter and this


parameter are enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None
4-484

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

None

4.21.15 DLDC support (INFO1_4_2)


Full Name

DLDC support

Abbreviation

INFO1_4_2

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether the cell supports downlink dual carrier.If
the network and MS support support downlink dual carrier, two carriers

Description

can be allocated to the downlink.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

[Trx]PairTrxId

Relationship

The PairTrxId parameter should be configured until this parameter is


enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-485
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.21.16 RTTI support (INFO1_4_3)


Full Name

RTTI support

Abbreviation

INFO1_4_3

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether to support RTTI function.
RTTI is relative to BTTI. BTTI is the basic transmission interval,
indicating to transmit one radio block with four consecutive bursts on
a channel in 20 ms.RTTI means to transmit one radio block with four
bursts on two channels in 10 ms, in which each channel provides two

Description

consecutive bursts respectively.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]RTTIPrefer

Relationship

The RTTIPrefer parameter should be configured until this parameter


is enabled.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-486
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.21.17 Enable event-based FANR in downlink TBF (INFO1_4_4)


Full Name

Enable event-based FANR in downlink TBF

Abbreviation

INFO1_4_4

3GPP Name

event-based FANR

3GPP Reference

3GPP TS 44.060
This parameter information is issued to MS in the packet downlink assignment, to indicate MS whether to use the event-based FANR. That is. MS
actively carries the received bitmap information of the downlink blocks in
the uplink radio block data after it finds that some of the downlink blocks

Description

are lost or out of sequence.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-487
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.21.18 Encoding mode of PAN in uplink TBF (INFO1_4_5)


Full Name

Encoding mode of PAN in uplink TBF

Abbreviation

INFO1_4_5

3GPP Name

Internal

3GPP Reference

None
This parameter information is issued to MS in the packet uplink assignment, to indicate the uplink TBF using the SSN-based encoding. That is,
the received bitmap encoding uses the received block bitmap format in

Description

the downlink response message.

Managed Object

Cell
0: SSN-based encoding

Value Range and Step

1: TIME-based encoding

Unit

None

Default Value

Default Value
Configuration Reason

This version only accomplishes the encoding based on SSN.

Configuration Rule and


Adjustment Suggestion

Currently, this parameter is always 0 and does not need to be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-488
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.21.19 Bep_Period2 of uplink (INFO1_4_6)


Full Name

Bep_Period2 of uplink

Abbreviation

INFO1_4_6

3GPP Name

Internal

3GPP Reference

None
The protocol (45.008) stipulates the calculation formula of the measurement data. An oblivion factor whose value is defined by the average period of the BEP filter is used in the formula. This parameter is used to
calculate the uplink measurement data of a certain MS inside of PCU and
takes priority over the general parameter BEPperiodUp. If this parameter

Description

is unavailable, use the parameter BEPperiodUp.

Managed Object

Cell
0..15

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default value is dependent upon the protocol recommended value.

Configuration Rule and


Adjustment Suggestion

Currently, this parameter is not used and does not need to be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-489
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.21.20 Bep_Period2 of downlink (INFO1_4_10)


Full Name

Bep_Period2 of downlink

Abbreviation

INFO1_4_10

3GPP Name

BEP_PERIOD2

3GPP Reference

3GPP TS V45.008
This parameter information is issued to the MS in PACCH/DL. The
protocol (45.008) stipulates the calculation formula of the measurement
data. An oblivion factor whose value is defined by the average period
of the BEP filter is used in the formula. This parameter information
is applied to a certain MS and takes priority over the parameter
BEPperiodDown broadcast in the system message 13 and packet
system message 13.If this parameter is unavailable, the MS uses the

Description

parameter BEPperiodDown.

Managed Object

Cell
0..15

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default value is dependent upon the protocol recommended value.

Configuration Rule and


Adjustment Suggestion

Currently, this parameter is not used and does not need to be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4-490
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.21.21 EGPRS2-A uplink initial coding scheme (EGPRS2AInitAtt


Selt_0)
Full Name

EGPRS2-A uplink initial coding scheme

Abbreviation

EGPRS2AInitAttSelt_0

3GPP Name

Internal

3GPP Reference

None
This parameter represents the coding scheme initially used by EGPRS2A

Description

MS in the uplink.

Managed Object

Cell
4: MCS1
5: MCS2
6: MCS3
7: MCS4
8: MCS5
9: MCS6
13: UAS7
14: UAS8
15: UAS9
16: UAS10

Value Range and Step

17: UAS11

Unit

None

Default Value

15: UAS9

Default Value

The intermediate value is taken according to the general wireless

Configuration Reason

environment.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]EGPRS2AInitAttSelt_2

Relationship

The value of EGPRS2AInitAttSelt_0 is not greater than that of


EGPRS2AInitAttSelt_2.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters
4-491

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.21.22 EGPRS2-A downlink initial coding scheme


(EGPRS2AInitAttSelt_1)
Full Name

EGPRS2-A downlink initial coding scheme

Abbreviation

EGPRS2AInitAttSelt_1

3GPP Name

Internal

3GPP Reference

None
This parameter represents the coding scheme initially used by EGPRS2A

Description

MS in the downlink.

Managed Object

Cell
4: MCS1
5: MCS2
6: MCS3
7: MCS4
13: DAS5
14: DAS6
15: DAS7
16: DAS8
17: DAS9
18: DAS10
19: DAS11

Value Range and Step

20: DAS12

Unit

None

Default Value

17: DAS9

Default Value

The intermediate value is taken according to the general wireless

Configuration Reason

environment.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

4-492
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.21.23 EGPRS2-A uplink maximum coding scheme


(EGPRS2AInitAttSelt_2)
Full Name

EGPRS2-A uplink maximum coding scheme

Abbreviation

EGPRS2AInitAttSelt_2

3GPP Name

Internal

3GPP Reference

None
This parameter represents the maximum coding scheme that can be used

Description

by EGPRS2A MS in the uplink.

Managed Object

Cell
4: MCS1
5: MCS2
6: MCS3
7: MCS4
8: MCS5
9: MCS6
13: UAS7
14: UAS8
15: UAS9
16: UAS10

Value Range and Step

17: UAS11

Unit

None

Default Value

17: UAS11

Default Value
Configuration Reason

The maximum coding scheme, which is currently supported, is used.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.


4-493

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

[Cell]EGPRS2AInitAttSelt_3

Relationship

The value of EGPRS2AInitAttSelt_1 is not greater than that of


EGPRS2AInitAttSelt_3.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.21.24 EGPRS2-A downlink maximum coding scheme


(EGPRS2AInitAttSelt_3)
Full Name

EGPRS2-A downlink maximum coding scheme

Abbreviation

EGPRS2AInitAttSelt_3

3GPP Name

Internal

3GPP Reference

None
This parameter represents the maximum coding scheme that can be used

Description

by EGPRS2A MS in the downlink.

Managed Object

Cell
4: MCS1
5: MCS2
6: MCS3
7: MCS4
13: DAS5
14: DAS6
15: DAS7
16: DAS8
17: DAS9
18: DAS10

Value Range and Step

19: DAS11

4-494
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

20: DAS12
Unit

None

Default Value

20: DAS12

Default Value
Configuration Reason

The maximum coding scheme, which is currently supported, is used.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.21.25 EGPRS2A MS initial code can be changed


(InitAttachExch_2)
Full Name

EGPRS2A MS initial code can be changed

Abbreviation

InitAttachExch_2

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether the coding method of GPRS/EGPRS

Description

MS in the cell could be changed dynamically.

Managed Object

Cell

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

1
4-495

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

The default value is enabled by default. The coding scheme can be

Configuration Reason

flexibly selected according to the radio environment.

Configuration Rule and

The function is achieved in the subsequent versions and does not need

Adjustment Suggestion

to be configured for the current version.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.21.26 Enable reduced latency access (RttiAccess)


Full Name

Enable reduced latency access

Abbreviation

RttiAccess

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the cell allows the reduced latency ac-

Description

cess on RTTI mobiles.

Managed Object

CELL
0: Not allowed

Value Range and Step

1: Allowed

Unit

None

Default Value

Default Value
Configuration Reason

None

4-496
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Configuration Rule and


Adjustment Suggestion

Open when this function is used.

Change Mode

Offline

Related features

Enhanced EDGE

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->EDGE parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.22 AMR-WB Parameter


4.22.1 Thresholds for AMR-WB (AmrWBThresholds_0~AmrWBT
hresholds_7)
Full Name

Thresholds for AMR-WB

Abbreviation

AmrWBThresholds_0~AmrWBThresholds_7

3GPP Name

AmrWBThresholds_0~AmrWBThresholds_7

3GPP Reference

45.009
This parameter determines the modified delay in the mode.
It consists of eight bits, representing two thresholds of AMR WFS, four

Description

thresholds of AMR OWFS, and two thresholds of AMR OWHS.

Managed Object

Cell

Value Range and Step

0..15

Unit

0.5dB
TCH/WFS: 14, 20

Default Value

other: 6

4-497
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

None

Configuration Rule and

Generally, it is not required to adjust the setting of this parameter unless

Adjustment Suggestion

the FER measured by the BTS exceeds 1%.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface, Abis Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR-WB


Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.22.2 Hysteresis for AMR-WB (AmrWBHysteresis_0~AmrWBHyst


eresis_7)
Full Name

Hysteresis for AMR-WB

Abbreviation

AmrWBHysteresis_0~AmrWBHysteresis_7

3GPP Name

hysteresis

3GPP Reference

45.009
This parameter determines the modified delay in the mode.
It consists of eight bits, representing two thresholds of AMR WFS, four

Description

thresholds of AMR OWFS, and two thresholds of AMR OWHS.

Managed Object

Cell

Value Range and Step

0..63

Unit

0.5dB

Default Value

6 for TCH/WFS, other: 3

Default Value
Configuration Reason

None
4-498

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Configuration Rule and


Adjustment Suggestion

By checking the frequency of rate adjustment, decide whether this


parameter is configured properly. When the rate is adjusted too
frequently, it is required to configure the parameter to a larger value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface, Abis Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->AMR-WB


Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.23 VAMOS Parameter


4.23.1 User label (UserLabel)
Full Name

User label

Abbreviation

UserLabel

3GPP Name

None

3GPP Reference

None

Description

This parameter facilitates subscribers to identify a cell name.

Managed Object

Cell

Value Range and Step

A string with 40 characters at most

Unit

None

Default Value

None

Default Value
Configuration Reason

None

4-499
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.23.2 BSC ID (OMCBSCID)


Full Name

BSC ID

Abbreviation

OMCBSCID

3GPP Name

None

3GPP Reference

None
The BSC ID cannot be modified. By default, it is the same as the subnet

Description

ID.

Managed Object

BSC

Value Range and Step

1..4095

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None
4-500

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.23.3 The identifier of the site (SITEID)


Full Name

The identifier of the site

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None
This parameter indicates the ID of this BTS, which cannot be modified.

Description

It is the same as the ID of an SDR management NE.

Managed Object

Site

Value Range and Step

1..1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

4-501
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.23.4 BTS ID (BTSID)


Full Name

BTS ID

Abbreviation

BTSID

3GPP Name

None

3GPP Reference

None
This parameter indicates the ID of this cell, which cannot be modified.

Description

It is the same as the ID of an SDR sector.

Managed Object

Cell
1..24
OB06: 3
BS20: 3
BS21: 3
BS21V20: 3
BS30: 3
BS30V12: 3
B8112: 6
M8202: 6
M8206: 6
B8018: 6
S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

according to the real number

Default Value
Configuration Reason

None

4-502
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

4.23.5 Support VAMOS (SupportVAMOS)


Full Name

Support VAMOS

Abbreviation

SupportVAMOS

3GPP Name

None

3GPP Reference

None
This parameter determines whether this cell supports the VAMOS func-

Description

tion.

Managed Object

Cell
0: not support VAMOS;

Value Range and Step

1: support VAMOS

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Enable the VAMOS function according to operator requirements.

Change Mode

Offline
4-503

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.6 Support MUTE SAIC detection (MuteSaicDetect)


Full Name

Support MUTE SAIC detection

Abbreviation

MuteSaicDetect

3GPP Name

None

3GPP Reference

None
This parameter determines whether this cell supports the function of

Description

MUTE SAIC detection.

Managed Object

Cell
0: not support MUTE SAIC detection;

Value Range and Step

1: support MUTE SAIC detection

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and

Enable the function of MUTE SAIC detection according to operator

Adjustment Suggestion

requirements.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

None

Relationship

None
4-504

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.7 Support SAIC AFC detection (SaicAfcDetect)


Full Name

Support SAIC AFC detection

Abbreviation

SaicAfcDetect

3GPP Name

None

3GPP Reference

None
This parameter determines whether this cell supports the function of SAIC

Description

AFC detection.

Managed Object

Cell
0: not support SAIC AFC detection;

Value Range and Step

1: support SAIC AFC detection

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and

Enable the function of SAIC AFC detection according to operator

Adjustment Suggestion

requirements.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

0
4-505

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.8 The priority level of VAMOS pairing (PriorLevelOfPair)


Full Name

The priority level of VAMOS pairing

Abbreviation

PriorLevelOfPair

3GPP Name

None

3GPP Reference

None
This parameter determines the priority threshold of the subscribers for
which pairing is allowed. Ensure certain voice quality for the subscribers
with high priority and do not perform pairing according to operator
requirements.
When enabling the VAMOS function, the system performs pairing only
for the subscribers with the priority lower than this threshold rather than

Description

the subscribers with high priority.

Managed Object

Cell

Value Range and Step

1..14

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

By default, pairing is allowed for all the subscribers.


Unless otherwise specified, pairing is allowed for all the subscribers.
If operators have special requirements, adjust the priority of the
subscribers for pairing as required.

Change Mode

Offline

Related features

ZGO-04-05-006 VAMOS Pairing Based on User Priority

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

0
4-506

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.9 The load of start VAMOS FR pairing (FRPairLoadThr,%)


Full Name

The load of start VAMOS FR pairing

Abbreviation

FRPairLoadThr

3GPP Name

None

3GPP Reference

None
This parameter determines the load threshold for the channel with the
VAMOS FR pairing enabled. When the cell load exceeds this threshold,

Description

the system triggers FR pairing.

Managed Object

Cell

Value Range and Step

20..100

Unit

Default Value

40

Default Value

When the cell load reaches 40%, it is required to enable the VAMOS FR

Configuration Reason

pairing to avoid congestion and enhance system capacity.


The larger the value of this parameter, the lower the possibility of

Configuration Rule and


Adjustment Suggestion

triggering FR pairing and the higher the possibility of cell congestion.


The smaller the value of this parameter, the higher the possibility of
triggering FR pairing. In this case, new VAMOS pairs will increase
interference to the system.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

[Cell]HRPairLoadThr

Relationship

FRPairLoadThr <= HRPairLoadThr

Related Interfaces

None

Impact on Equipment

4-507
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.10 The load of start VAMOS HR pairing (HRPairLoadThr,%)


Full Name

The load of start VAMOS HR pairing

Abbreviation

HRPairLoadThr

3GPP Name

None

3GPP Reference

None
This parameter determines the load threshold for the channel with the
VAMOS HR pairing enabled. When the cell load exceeds this threshold,

Description

the system triggers FR or HR pairing.

Managed Object

Cell

Value Range and Step

20..100

Unit

Default Value

80

Default Value

When the cell load reaches 80%, that cell is regarded as busy. It is

Configuration Reason

required to enable the VAMOS HR pairing to enhance system capacity.


The larger the value of this parameter, the lower the possibility of

Configuration Rule and


Adjustment Suggestion

triggering HR pairing and the higher the possibility of cell congestion.


The smaller the value of this parameter, the higher the possibility of
triggering HR pairing. In this case, new VAMOS pairs will increase
interference to the system.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

[Cell]FRPairLoadThr

Relationship

FRPairLoadThr <= HRPairLoadThr

Related Interfaces

None

Impact on Equipment

4-508
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.11 The level threshold of Vamos paring (LevThrOfPair)


Full Name

The level threshold of Vamos paring

Abbreviation

LevThrOfPair

3GPP Name

None

3GPP Reference

None
This parameter determines the receiving level threshold for pairing.
For two subscribers that multiplex a same timeslot, there are certain
requirements on the receiving quality and level of the subscribers before
the pairing. This ensures that they can work properly after pairing and

Description

does not affect other subscribers in the system.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

30

Default Value

Usually, the subscribers with the level larger than -80 dB have good

Configuration Reason

pairing effect and are not easy to cause pair release or call drop.
The larger the value of this parameter, the higher the requirements on
the receiving level of the subscribers before pairing and the harder the

Configuration Rule and

pairing to be performed.

Adjustment Suggestion

The smaller the value of this parameter, the lower the requirements on
the receiving level of the subscribers before pairing and the higher the
possibility that pair release or call drop occurs.

Change Mode

Offline

Related features

ZGO-04-05-004 VAMOS Pairing Based on Signal Level and Quality

Related Parameters

None

Relationship

None

4-509
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.12 The quality threshold of Vamos paring (QualThrOfPair)


Full Name

The quality threshold of Vamos paring

Abbreviation

QualThrOfPair

3GPP Name

None

3GPP Reference

None
This parameter determines the receiving quality threshold for pairing.
For two subscribers that multiplex a same timeslot, there are certain
requirements on the receiving quality and level of the subscribers before
the pairing. This ensures that they can work properly after pairing and

Description

does not affect other subscribers in the system.

Managed Object

Cell

Value Range and Step

0..70

Unit

None

Default Value

10

Default Value

Usually, the subscribers with the quality smaller than 1 have good pairing

Configuration Reason

effect and are not easy to cause pair release or call drop.
The smaller the value of this parameter, the higher the requirements on
the receiving quality of the subscribers before pairing and the harder

Configuration Rule and

the pairing to be performed.

Adjustment Suggestion

The larger the value of this parameter, the lower the requirements on
the receiving quality of the subscribers before pairing and the higher the
possibility that pair release or call drop occurs.

Change Mode

Offline

Related features

ZGO-04-05-004 VAMOS Pairing Based on Signal Level and Quality

4-510
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.13 The path loss ratio of candidates (PassLossRatio)


Full Name

The path loss ratio of candidates

Abbreviation

PassLossRatio

3GPP Name

None

3GPP Reference

None
This parameter determines the path loss threshold for pairing.

Description

The subscribers with closer path loss have good pairing effect.

Managed Object

Cell

Value Range and Step

0..100

Unit

None

Default Value

10

Default Value

Usually, the subscribers with the path loss ratio lower than 10% have

Configuration Reason

similar radio environments and the pairing is easy to be successful.


The smaller the value of this parameter, the higher the requirements
on the path loss ratio of the subscribers before pairing and the harder

Configuration Rule and

the pairing to be performed.

Adjustment Suggestion

The larger the value of this parameter, the lower the requirements on
the path loss ratio of the subscribers before pairing and the higher the
possibility that pair release or call drop occurs.

Change Mode

Offline

Related features

ZGO-04-05-005 VAMOS Pairing Based on Path Loss

4-511
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.14 The expected received level (ExpectedLev)


Full Name

The expected received level

Abbreviation

ExpectedLev

3GPP Name

None

3GPP Reference

None
This parameter determines the target level value after pairing, that is, the

Description

minimum downlink level of the subscribers after pairing.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

20

Default Value

Usually, the downlink receiving level after pairing can reach over -100

Configuration Reason

dB. In this case, subscriber calls can be normally made.


The larger the value of this parameter, the higher the requirements on
the downlink receiving level of the subscribers after pairing. In this case,

Configuration Rule and


Adjustment Suggestion

the required power is higher and the pairing to be performed is harder.


The smaller the value of this parameter, the lower the requirements on
the downlink receiving level of the subscribers after pairing. Although
the pairing is easy to be performed, the possibility that pair release or
call drop occurs is higher.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing


4-512

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.15 The uplink SCPIR threshold (SCPIR_Up)


Full Name

The uplink SCPIR threshold

Abbreviation

SCPIR_Up

3GPP Name

None

3GPP Reference

None
This parameter determines the SCPIR value of weak subscribers to strong

Description

subscribers.

Managed Object

Cell
15..30
value meaning
0 -15
1 -14
2 -13
...

Value Range and Step

30 15

Unit

None

Default Value

25

Default Value
Configuration Reason

When the uplink SCPIR is more than 10, the pairing effect is the best.

4-513
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The larger the value of this parameter, the higher the requirements on
the SCPIR of the subscribers for pairing and the harder the pairing to be
Configuration Rule and
Adjustment Suggestion

performed.
The smaller the value of this parameter, the lower the requirements on
the SCPIR of the subscribers for pairing. Although the pairing is easy
to be performed, the possibility that pair release or call drop occurs is
higher.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.16 The downlink SCPIR threshold of NON-SAIC MS


(SCPIR_Dn_NoSaic)
Full Name

The downlink SCPIR threshold of NON-SAIC MS

Abbreviation

SCPIR_Dn_NoSaic

3GPP Name

None

3GPP Reference

None
This parameter determines the downlink SCPIR threshold for traditional

Description

MSs.

Managed Object

Cell

4-514
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

21..30
value meaning
0 -15
1 -14
2 -13
...
Value Range and Step

30 15

Unit

None

Default Value

21

Default Value
Configuration Reason

When the downlink SCPIR is more than 6, the pairing effect is the best.
The larger the value of this parameter, the higher the requirements on
the SCPIR of the subscribers for pairing and the harder the pairing to be

Configuration Rule and


Adjustment Suggestion

performed.
The smaller the value of this parameter, the lower the requirements on
the SCPIR of the subscribers for pairing. Although the pairing is easy
to be performed, the possibility that pair release or call drop occurs is
higher.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.17 The downlink SCPIR threshold of SAIC MS (SCPIR_Dn_Saic)


Full Name

The downlink SCPIR threshold of SAIC MS

Abbreviation

SCPIR_Dn_Saic
4-515

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

None

3GPP Reference

None

Description

This parameter determines the downlink SCPIR threshold for SAIC MSs.

Managed Object

Cell
11..30
value meaning
0 -15
1 -14
2 -13
...

Value Range and Step

30 15

Unit

None

Default Value

11

Default Value
Configuration Reason

When the downlink SCPIR is more than -4, the pairing effect is the best.
The larger the value of this parameter, the higher the requirements on
the SCPIR of the subscribers for pairing and the harder the pairing to be

Configuration Rule and


Adjustment Suggestion

performed.
The smaller the value of this parameter, the lower the requirements on
the SCPIR of the subscribers for pairing. Although the pairing is easy
to be performed, the possibility that pair release or call drop occurs is
higher.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4-516
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.23.18 The downlink SCPIR threshold of SAIC AFC MS


(SCPIR_Dn_SaicAfc)
Full Name

The downlink SCPIR threshold of SAIC AFC MS

Abbreviation

SCPIR_Dn_SaicAfc

3GPP Name

None

3GPP Reference

None
This parameter determines the downlink SCPIR threshold for SAIC AFC

Description

MSs.

Managed Object

Cell
15..30
value meaning
0 -15
1 -14
2 -13
...

Value Range and Step

30 15

Unit

None

Default Value

15

Default Value
Configuration Reason

When the downlink SCPIR is more than 0, the pairing effect is the best.
The larger the value of this parameter, the higher the requirements on
the SCPIR of the subscribers for pairing and the harder the pairing to be

Configuration Rule and


Adjustment Suggestion

performed.
The smaller the value of this parameter, the lower the requirements on
the SCPIR of the subscribers for pairing. Although the pairing is easy
to be performed, the possibility that pair release or call drop occurs is
higher.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-517
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.19 The downlink SCPIR threshold of VAMOS I MS


(SCPIR_Dn_VAMOSI)
Full Name

The downlink SCPIR threshold of VAMOS I MS

Abbreviation

SCPIR_Dn_VAMOSI

3GPP Name

None

3GPP Reference

None
This parameter determines the downlink SCPIR threshold for VAMOSv1

Description

MSs.

Managed Object

Cell
11..30
value meaning
0 -15
1 -14
2 -13
...

Value Range and Step

30 15

Unit

None

Default Value

11

Default Value
Configuration Reason

When the downlink SCPIR is more than -4, the pairing effect is the best.
The larger the value of this parameter, the higher the requirements on
the SCPIR of the subscribers for pairing and the harder the pairing to be

Configuration Rule and


Adjustment Suggestion

performed.
The smaller the value of this parameter, the lower the requirements on
the SCPIR of the subscribers for pairing. Although the pairing is easy
to be performed, the possibility that pair release or call drop occurs is
higher.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

4-518
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.20 The downlink SCPIR threshold of VAMOS II MS


(SCPIR_Dn_VAMOSII)
Full Name

The downlink SCPIR threshold of VAMOS II MS

Abbreviation

SCPIR_Dn_VAMOSII

3GPP Name

None

3GPP Reference

None
This parameter determines the downlink SCPIR threshold for VAMOSv2

Description

MSs.

Managed Object

Cell
5..30
value meaning
0 -15
1 -14
2 -13
...

Value Range and Step

30 15

Unit

None

Default Value

Default Value
Configuration Reason

When the downlink SCPIR is more than -10, the pairing effect is the best.

4-519
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The larger the value of this parameter, the higher the requirements on
the SCPIR of the subscribers for pairing and the harder the pairing to be
Configuration Rule and
Adjustment Suggestion

performed.
The smaller the value of this parameter, the lower the requirements on
the SCPIR of the subscribers for pairing. Although the pairing is easy
to be performed, the possibility that pair release or call drop occurs is
higher.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.21 P value of total power or SCPIR overflow


(PowerOrScpirOverP)
Full Name

P value of total power or SCPIR overflow

Abbreviation

PowerOrScpirOverP

3GPP Name

None

3GPP Reference

None
This parameter determines the P value used when the system detects
whether the total power or SCPIR exceeds the threshold.
The BTS determines whether to release pairs during power control. The
judge process is as follows: If the total power or uplink/downlink SCPIR
of two subscribers exceeds the threshold during P out of recent N times
of power control, the system considers that these two subscribers are

Description

not suitable for pairing and thus initiates the process of pair release.

Managed Object

Cell
4-520

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Value Range and Step

1..20

Unit

None

Default Value

Default Value

It is recommended that this parameter be configured to 3, so as to

Configuration Reason

ensure that the judge process of pair release is precise and quick.
If this parameter is configured too small, there are few samples used for

Configuration Rule and


Adjustment Suggestion

pair release judgment and thus the pair release judgment is not precise.
If this parameter is configured too large, the time for pair release
judgment is excessively long and thus call drops may occurs because
the pair release is late.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

[Cell]PowerOrScpirOverN

Relationship

PowerOrScpirOverP <= PowerOrScpirOverN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.22 N value of total power or SCPIR overflow


(PowerOrScpirOverN)
Full Name

N value of total power or SCPIR overflow

Abbreviation

PowerOrScpirOverN

3GPP Name

None

3GPP Reference

None

4-521
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines the N value used when the system detects
whether the total power or SCPIR exceeds the threshold.
The BTS determines whether to release pairs during power control. The
judge process is as follows: If the total power or uplink/downlink SCPIR
of two subscribers exceeds the threshold during P out of recent N times
of power control, the system considers that these two subscribers are
Description

not suitable for pairing and thus initiates the process of pair release.

Managed Object

Cell

Value Range and Step

1..20

Unit

None

Default Value

Default Value

It is recommended that this parameter be configured to 4, so as to

Configuration Reason

ensure that the judge process of pair release is precise and quick.
If this parameter is configured too small, there are few samples used for

Configuration Rule and


Adjustment Suggestion

pair release judgment and thus the pair release judgment is not precise.
If this parameter is configured too large, the time for pair release
judgment is excessively long and thus call drops may occurs because
the pair release is late.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

[Cell]PowerOrScpirOverP

Relationship

PowerOrScpirOverP <= PowerOrScpirOverN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.23 The detection quality threshold (SaicDetQual)


Full Name

The detection quality threshold

4-522
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Abbreviation

SaicDetQual

3GPP Name

None

3GPP Reference

None
This parameter determines the quality threshold of SAIC and AFC
detection. The quality before MUTE SAIC and AFC scrambling must
meet this threshold.
This parameter will be delivered to BTSs and thus this parameter still

Description

ranges from 0 to 7.

Managed Object

Cell

Value Range and Step

0..7

Unit

None

Default Value

2
When the subscriber quality is lower than 2, the system can perform

Default Value

SAIC and AFC detection. Otherwise, if scrambling exists in the case of

Configuration Reason

poor quality, the voice quality will be deteriorated seriously. In addition,


call drops occur.

Configuration Rule and


Adjustment Suggestion

This parameter must be configured too large because the current quality
is poor. In this case, if scrambling exists, the quality will be deteriorated
seriously and thus call drops occur.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4-523
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.23.24 P value of MUTE SAIC detection (MuteSaicDetectP)


Full Name

P value of MUTE SAIC detection

Abbreviation

MuteSaicDetectP

3GPP Name

None

3GPP Reference

None
This parameter determines the P value used during MUTE SAIC
detection. The N value is fixed to 10.
The judge process of MUTE SAIC detection is as follows: The BTS
periodically sends -QPSK test signals to a terminal. If certain
scrambling exists in the downlink direction when the downlink RQ is
good, the system determines whether an MS supports the SAIC function
according to the RQ value reported by the MS. If the downlink receiving
quality is higher than the threshold for P out of continuous N scrambling

Description

periods, the system considers the MS as a MUTE SAIC MS.

Managed Object

Cell

Value Range and Step

1..10

Unit

None

Default Value

Default Value

It is recommended that this parameter be configured to 6, so as to

Configuration Reason

ensure that the judge process of MUTE SAIC detection is precise.


If this parameter is configured too small, there are few samples used for

Configuration Rule and

judgment and thus the judgment is not precise.

Adjustment Suggestion

If this parameter is configured too large, the time for judgment is


excessively long and thus the interference in the system is increasing.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

4-524
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

New

4.23.25 Thresholdof Frequecy Shift (FreqShiftThre,Hz)


Full Name

Thresholdof Frequecy Shift

Abbreviation

FreqShiftThre

3GPP Name

None

3GPP Reference

None
This parameter determines the frequency deviation of SAIC AFC detection. If the detection result is higher than this threshold, the system con-

Description

siders that the MS is a faulty AFC MS.

Managed Object

Cell

Value Range and Step

0..1000

Unit

Hz

Default Value

400

Default Value
Configuration Reason

Generally, frequency deviation within 400 Hz is acceptable.

Configuration Rule and


Adjustment Suggestion

It is recommended that this parameter be not adjusted.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4-525
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.23.26 The time of SAIC AFC detection (SaicAfcDetectTime)


Full Name

The time of SAIC AFC detection

Abbreviation

SaicAfcDetectTime

3GPP Name

None

3GPP Reference

None
This parameter determines the duration of SAIC AFC detection.

Description

This parameter determines the number of valid uplink bursts.

Managed Object

Cell

Value Range and Step

1..40

Unit

None

Default Value

15

Default Value

It is recommended that this parameter be configured to 15, so as to

Configuration Reason

ensure that the judge process of MUTE SAIC detection is precise.


If this parameter is configured too small, there are few samples used for

Configuration Rule and

judgment and thus the judgment is not precise.

Adjustment Suggestion

If this parameter is configured too large, the interference in the system is


increasing.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.23.27 P value of SAIC AFC detection (SaicAfcDetectP)


Full Name

P value of SAIC AFC detection


4-526

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Abbreviation

SaicAfcDetectP

3GPP Name

None

3GPP Reference

None
This parameter determines the P value used for SAIC AFC detection.
The process of SAIC AFC detection is as follows: The BTS sends
-QPSK test signals to a terminal and adds certain interference signals
in the downlink direction, and meanwhile detects the frequency deviation
of each valid uplink burst. If P out of continuous N uplink bursts meet this
threshold, the system considers that the MS is a faulty AFC MS. If the
above condition is not met within the test period, the system considers

Description

that the MS is not a faulty AFC MS.

Managed Object

Cell

Value Range and Step

1..20

Unit

None

Default Value

Default Value

It is recommended that this parameter be configured to 5, so as to

Configuration Reason

ensure that the judge process of MUTE SAIC detection is precise.


If this parameter is configured too small, there are few samples used for

Configuration Rule and

judgment and thus the judgment is not precise.

Adjustment Suggestion

If this parameter is configured too large, the time for judgment is


excessively long and thus the interference in the system is increasing.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

[Cell]SaicAfcDetectN

Relationship

SaicAfcDetectP <= SaicAfcDetectN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4-527
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.23.28 N value of SAIC AFC detection (SaicAfcDetectN)


Full Name

N value of SAIC AFC detection

Abbreviation

SaicAfcDetectN

3GPP Name

None

3GPP Reference

None
This parameter determines the N value used for SAIC AFC detection.
The process of SAIC AFC detection is as follows: The BTS sends
-QPSK test signals to a terminal and adds certain interference signals
in the downlink direction, and meanwhile detects the frequency deviation
of each valid uplink burst. If P out of continuous N uplink bursts meet this
threshold, the system considers that the MS is a faulty AFC MS. If the
above condition is not met within the test period, the system considers

Description

that the MS is not a faulty AFC MS.

Managed Object

Cell

Value Range and Step

1..20

Unit

None

Default Value

10

Default Value

It is recommended that this parameter be configured to 10, so as to

Configuration Reason

ensure that the judge process of MUTE SAIC detection is precise.


If this parameter is configured too small, there are few samples used for

Configuration Rule and

judgment and thus the judgment is not precise.

Adjustment Suggestion

If this parameter is configured too large, the time for judgment is


excessively long and thus the interference in the system is increasing.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

[Cell]SaicAfcDetectP

Relationship

SaicAfcDetectP <= SaicAfcDetectN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->VAMOS


Parameter

Parameter Modifying
Version

iBSCV6.20.710

4-528
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

New

4.24 Cell Power Parameter


4.24.1 UpLink optimize method for immediate assignment
(PwrOptCtrl_0)
Full Name

UpLink optimize method for immediate assignment

Abbreviation

PwrOptCtrl_0

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the uplink power optimization mode in the

Description

case of immediate assignment.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

Usually, the maximum power can be used during immediate optimization.

Configuration Rule and

Usually, this parameter is configured to "No". To reduce interference by

Adjustment Suggestion

optimizing the initial power, this parameter can be configured to "Yes".

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

4-529
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.24.2 DownLink optimize method for immediate assignment


(PwrOptCtrl_4)
Full Name

DownLink optimize method for immediate assignment

Abbreviation

PwrOptCtrl_4

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the downlink power optimization mode in the

Description

case of immediate assignment.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

Usually, the maximum power can be used during immediate optimization.

Configuration Rule and

by optimizing the initial power or to improve the success rate of

Adjustment Suggestion

power admission by using the function of dynamic power sharing, this

Usually, this parameter is configured to "No". To reduce interference

parameter can be configured to "Yes".


Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

4-530
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.24.3 UpLink optimize method for assignment or intracell


handover (PwrOptCtrl_8)
Full Name

UpLink optimize method for assignment or intracell handover

Abbreviation

PwrOptCtrl_8

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the uplink power optimization mode in the

Description

case of assignment and inner-cell handover.

Managed Object

Cell
Not Optimize, Inherit power of previous channel, Optimize according to

Value Range and Step

target level

Unit

None

Default Value

Not Optimize

Default Value
Configuration Reason

Using the maximum power has certain benefits.


To reduce interference by optimizing the initial power, it is required to
inherit the power of the original channel or optimize the power by using

Configuration Rule and


Adjustment Suggestion

the target level.


The power of the original channel is used because the power control has
been implemented on the original channel. If the original channel does
not implement power control in time, it is required to optimize the power
by using the target level.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-531
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.24.4 DownLink optimize method for assignment or intracell


handover (PwrOptCtrl_12)
Full Name

DownLink optimize method for assignment or intracell handover

Abbreviation

PwrOptCtrl_12

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the downlink power optimization mode in the

Description

case of assignment and inner-cell handover.

Managed Object

Cell
Not Optimize, Inherit power of previous channel, Optimize according to

Value Range and Step

target level

Unit

None

Default Value

Not Optimize

Default Value
Configuration Reason

Using the maximum power has certain benefits.


To reduce interference by optimizing the initial power or improve the
success rate of power admission by using the function of dynamic power
sharing, it is required to inherit the power of the original channel or

Configuration Rule and

optimize the power by using the target level.

Adjustment Suggestion

The power of the original channel is used because the power control has
been implemented on the original channel. If the original channel does
not implement power control in time, it is required to optimize the power
by using the target level.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

4-532
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.24.5 UpLink optimize method for intercell handover


(PwrOptCtrl_16)
Full Name

UpLink optimize method for intercell handover

Abbreviation

PwrOptCtrl_16

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the uplink power optimization mode in the

Description

case of inter-cell handover.

Managed Object

Cell
Not Optimize, Inherit power of previous channel, Optimize according to

Value Range and Step

target level

Unit

None

Default Value

Not Optimize

Default Value
Configuration Reason

Using the maximum power has certain benefits.


To reduce interference by optimizing the initial power, it is required to

Configuration Rule and


Adjustment Suggestion

inherit the power of the original channel or optimize the power by using
the target level.
These two modes are commonly used. Which mode will be used
depends on the operator preference.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

4-533
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.24.6 DownLink optimize method for intercell handover


(PwrOptCtrl_20)
Full Name

DownLink optimize method for intercell handover

Abbreviation

PwrOptCtrl_20

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the downlink power optimization mode in the

Description

case of inter-cell handover.

Managed Object

Cell

Value Range and Step

Not Optimize, Optimize according to target level

Unit

None

Default Value

Not Optimize

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Using the maximum power has certain benefits.


To reduce interference by optimizing the initial power or improve the
success rate of power admission by using the function of dynamic power
sharing, it is required to optimize the power by using the target level.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

0
4-534

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.24.7 Uplink target level (UlTargetLevel)


Full Name

Uplink target level

Abbreviation

UlTargetLevel

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the uplink target level for power optimization.
When the system uses the uplink target level for power optimization, it is
required to adjust the initial transmission power of the MS, so as to make

Description

the receiving level of the BTS reach this value.

Managed Object

Cell
0..63, Step: 1
(0: <-110dBm; 1: -110dBm..-109dBm; ... ; 62: -49dBm..-48dBm; 63:

Value Range and Step

>-48dBm)

Unit

dB

Default Value

30

Default Value
Configuration Reason

Usually, -80 dBm is considered as a strong uplink receiving level.


It is required to configure this parameter according to the network level
or quality distribution, so as to ensure good quality when this level is

Configuration Rule and

applied.

Adjustment Suggestion

If this parameter is configured too high, the effect of power optimization


is not obvious. If this parameter is configured too low, access to the
new channel may fail.

Change Mode

Offline

Related features

None

Related Parameters

None

4-535
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.24.8 Downlink target level (DlTargetLevel)


Full Name

Downlink target level

Abbreviation

DlTargetLevel

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the downlink target level for power optimization. When the system uses the downlink target level for power optimization, it is required to adjust the initial transmission power of the BTS, so

Description

as to make the receiving level of the MS reach this value.

Managed Object

Cell
0..63, Step: 1
(0: <-110dBm; 1: -110dBm..-109dBm; ... ; 62: -49dBm..-48dBm; 63:

Value Range and Step

>-48dBm)

Unit

dB

Default Value

35

Default Value
Configuration Reason

Usually, -75 dBm is considered as a strong downlink receiving level.


It is required to configure this parameter according to the network level
or quality distribution, so as to ensure good quality when this level is

Configuration Rule and

applied.

Adjustment Suggestion

If this parameter is configured too high, the effect of power optimization


is not obvious. If this parameter is configured too low, access to the
new channel may fail.

4-536
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.24.9 Low RSSI threshold (LowRssiThs)


Full Name

Low RSSI threshold(LowRssiThs)

Abbreviation

LowRssiThs

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the lower RSSI threshold for power
optimization.
When an MS accesses the network for the first time, the BTS detects
the level RSSI of access pulse in the request on the RACH channel and
reports the RSSI to the BSC. Then, the BSC classifies the receiving level
into high, medium, and low levels according to the configured thresholds
of LOWRSSITHS and HIGHRSSITHS.
Decrease the MS power during immediate assignment.
When RSSI is smaller than LOWRSSITHS, MSPower_Opt is equal to
MSTXPowerMax.
When LOWRSSITHS is equal to or smaller than RSSI<HIGHRSSITHS,
MSPower_Opt is equal to MSTXPowerMax-2dB.
When RSSI is larger than or equal to HIGHRSSITHS, MSPower_Opt
is equal to MSTXPowerMax-4dB.
For symmetry of upstream and downstream links, the same judgment

Description

mode is applied for the downstream link, so as to decrease the power.

4-537
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Note: There is no MSPOWER parameter in an immediate assignment


message and therefore the uplink power cannot be specified.
The MS power is sent to the BTS through an activation channel message
and then to the MS after being encapsulated on the SACCH frame
header. Therefore, there will be a small delay.
Managed Object

Cell
0..63, Step: 1
(0: <-110dBm; 1: -110dBm..-109dBm; ....62: -49dBm..-48dBm;63:

Value Range and Step

>-48dBm)

Unit

dB

Default Value

32

Default Value
Configuration Reason

Usually, -78 dBm on the RACH channel is considered as a strong


receiving level. In the case of immediate assignment, the power can be
decreased by 2 dB.
It is required to configure this parameter according to the network level
or quality distribution, so as to ensure that the RACH channel reaches
this level.

Configuration Rule and

Even when the uplink power and downlink power are deceased by 2 dB,

Adjustment Suggestion

the voice quality is still good. It is recommended that this parameter be


configured to a conservative value because the RACH signal has only
one pulse and thus the measurement precision of the signal strength is
relatively poor when compared with that of dedicated channels.

Change Mode

Offline

Related features

None

Related Parameters

HighRssiThs

Relationship

R_BTS2.HighRssiThs > R_BTS2.LowRssiThs

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4-538
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.24.10 High RSSI Threshold (HighRssiThs)


Full Name

High RSSI Threshold

Abbreviation

HighRssiThs

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the upper RSSI threshold for power
optimization.
When an MS accesses the network for the first time, the BTS detects the
level RSSI of access pulse requested on the RACH channel and reports
the RSSI to the BSC. Then, the BSC classifies the receiving level into
high, medium, and low levels according to the configured thresholds of
LOWRSSITHS and HIGHRSSITHS.
Decrease the MS power during immediate assignment.
When RSSI is smaller than LOWRSSITHS, MSPower_Opt is equal to
MSTXPowerMax.
When LOWRSSITHS is equal to or smaller than RSSI<HIGHRSSITHS,
MSPower_Opt is equal to MSTXPowerMax-2dB.
When RSSI is larger than or equal to HIGHRSSITHS, MSPower_Opt
is equal to MSTXPowerMax-4dB.
For symmetry of upstream and downstream links, the same judgment
mode is applied for the downstream link, so as to decrease the power.
Note: There is no MSPOWER parameter in an immediate assignment
message and therefore the uplink power cannot be specified.
The MS power is sent to the BTS through an activation channel message
and then to the MS after being encapsulated on the SACCH frame

Description

header. Therefore, there will be a small delay.

Managed Object

Cell
0..63, Step: 1
(0: <-110dBm; 1: -110dBm..-109dBm; ....62: -49dBm..-48dBm;63:

Value Range and Step

>-48dBm)

Unit

dB

Default Value

38

Default Value
Configuration Reason

Usually, -72 dBm on the RACH channel is considered as a strong


receiving level. In the case of immediate assignment, the power can be
decreased by 4 dB.

4-539
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

It is required to configure this parameter according to the network level


or quality distribution, so as to ensure that the RACH channel reaches
this level.
Configuration Rule and

Even when the uplink power and downlink power are deceased by 4 dB,

Adjustment Suggestion

the voice quality is still good. It is recommended that this parameter is


configured to a conservative value because the RACH signal has only
one pulse and thus the measurement precision of the signal strength is
relatively poor when compared with that of dedicated channels.

Change Mode

Offline

Related features

None

Related Parameters

LowRssiThs

Relationship

R_BTS2.HighRssiThs > R_BTS2.LowRssiThs

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.24.11 Ms power inherit threshold (MsPwrInheritThs)


Full Name

Ms power inherit threshold

Abbreviation

MsPwrInheritThs

3GPP Name

Internal Defination

3GPP Reference

None
This parameter is valid when the MS power optimization for non-rescue
handover is enabled. When the BSC sends a handover command to the
MS for a non-rescue handover such as PBGT handover, if the current level
is higher than this threshold and meanwhile PBGT occurs, it indicates that
the target cell has better signal quality. In this case, the original transmit

Description

power instead of the maximum transmit power can be used for handover.

Managed Object

Cell

4-540
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

0..63, Step: 1
(0: <-110dBm; 1: -110dBm..-109dBm; ....62: -49dBm..-48dBm;63:
Value Range and Step

>-48dBm)

Unit

dB

Default Value

27

Default Value

The level with the radio strength of -83 dB can ensure normal operation

Configuration Reason

of services.

Configuration Rule and

It is required to configure this parameter according to the actual

Adjustment Suggestion

application on site, network condition, and network optimization plan.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.24.12 Power dynamic sharing (PwrDynShare)


Full Name

Power dynamic sharing

Abbreviation

PwrDynShare

3GPP Name

None

3GPP Reference

None
This parameter determines whether to enable the function of dynamic

Description

power sharing in this cell.

Managed Object

Cell

4-541
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.


To enable the function of dynamic power sharing in this cell, enable

Configuration Rule and


Adjustment Suggestion

this switch. This helps increase the usage of cell power resources by
sharing unused power of the carriers that have small transmit power with
the carriers that require large transmit power. In this way, the maximum
transmit power of each carrier is increased.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

PwrControlDl

Relationship

If this switch is not enabled for the first subcell in this cell or the BTS is
not an SDR BTS, this parameter cannot be configured to "Yes".

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

It is changed to a cell parameter from a power control parameter.

4.24.13 Power reserved for present users (PwrPres)


Full Name

Power reserved for present users

Abbreviation

PwrPres

3GPP Name

None

3GPP Reference

None

4-542
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

This parameter determines the reserved power volume, that is, the gain
level with the current used power as the reference. The available values
are 0, 1, 2, 3, and 4, representing gains 0 dB, 0.5 dB, 1 dB, 1.5 dB, and
Description

2 dB.

Managed Object

Cell

Value Range and Step

0[0], 0.5[1], 1[2], 1.5[3], 2[4]

Unit

None

Default Value

0[0]

Default Value
Configuration Reason

By default, the power gain is 0 dB.

Configuration Rule and


Adjustment Suggestion

It is recommended that the default value be used.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

It is changed to a cell parameter from a power control parameter.

4.24.14 Power Adjusting Threshold (PwrAdjustThreshold)


Full Name

Power Adjusting Threshold

Abbreviation

PwrAdjustThreshold

3GPP Name

None

3GPP Reference

None

4-543
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines the power congestion control threshold. When


detecting that a current service on the RRU occupies a certain percentage
to the total power of RRU, the BSC performs congestion control to hand
Description

out the CS service.

Managed Object

Cell

Value Range and Step

50..100

Unit

Default Value

100

Default Value

By default, 100% is a value considered as congestion. If this parameter

Configuration Reason

is not configured properly, services may be affected.


It is recommended that PwrAdjPriority_0 be configured to handout CS
service, PwrAdjPriority_1 be configured to decrease of PDTCH channel

Configuration Rule and

power, and PwrAdjPriority_2, PwrAdjPriority_3, and PwrAdjPriority_4 be

Adjustment Suggestion

configured to invalid algorithms.


Handout of the CS service has little impact on the voice quality. Decrease
of the PDTCH channel power has certain impact on the PS performance.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

Inc8PskPwrThs, Inc8PskPwrHys

Relationship

Inc8PskPwrThs +Inc8PskPwrHys < PwrAdjustThreshold

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

It is changed to a cell parameter from a power control parameter.

4.24.15 Power admitting threshold (PwrAdmitThreshold)


Full Name

Power admitting threshold

Abbreviation

PwrAdmitThreshold

3GPP Name

None
4-544

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

3GPP Reference

None
This parameter determines the power access control threshold. When the
BSC receives a new service application, if the sum of the power occupied
by the current service of a timeslot on the RRU and the downlink transmit
power required by the access of a new subscriber reaches the total power
of RRU, the BSC does not access this service in the timeslot but selects

Description

another timeslot for access judgment.

Managed Object

Cell

Value Range and Step

10..100

Unit

Default Value

90

Default Value

When the value reaches 90%, the system considers that the RRU power

Configuration Reason

reaches the upper threshold and does not assign power.


It is recommended that PwrAdjPriority_0 be configured to handout CS
service, PwrAdjPriority_1 be configured to decrease of PDTCH channel

Configuration Rule and

power, and PwrAdjPriority_2, PwrAdjPriority_3, and PwrAdjPriority_4 be

Adjustment Suggestion

configured to invalid algorithms.


Handout of the CS service has little impact on the voice quality. Decrease
of the PDTCH channel power has certain impact on the PS performance.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

PwrAdmitThrldPunish, PwrAdjustThreshold

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

It is changed to a cell parameter from a power control parameter.

4-545
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.24.16 Power admitting threshold punishment (PwrAdmitThrldP


unish)
Full Name

Power admitting threshold punishment

Abbreviation

PwrAdmitThrldPunish

3GPP Name

None

3GPP Reference

None
This parameter determines the penalty degree of power access control
threshold. When a service is kicked out for a timeslot of an RRU due to
power congestion, a new service will be accessed immediately to prevent
the current power from being decreased directly below the access threshold. As a result, oscillation from the congestion state to the non-congestion state occurs. At this time, the system decreases the access threshold
for a period of time as penalty. This parameter determines the penalty de-

Description

gree.

Managed Object

Cell

Value Range and Step

0..50

Unit

Default Value

10

Default Value

Generally, the penalty degree of 10% is enough to avoid the ping-pong

Configuration Reason

effect caused by power congestion.

Configuration Rule and


Adjustment Suggestion

It is recommended that the default value be used.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

PwrAdmitThreshold, PwrAdjustThreshold

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

It is changed to a cell parameter from a power control parameter.


4-546

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

4.24.17 Power admitting threshold punishment time


(PwrAdmitPunishTime)
Full Name

Power admitting threshold punishment time

Abbreviation

PwrAdmitPunishTime

3GPP Name

None

3GPP Reference

None
This parameter determines the penalty period of power access control
threshold. When a service is kicked out for a timeslot of an RRU due to
power congestion, a new service will be accessed immediately to prevent
the current power from being decreased directly below the access threshold. As a result, oscillation from the congestion state to the non-congestion state occurs. At this time, the system decreases the access threshold for a period of time as penalty. This parameter determines the penalty

Description

time.

Managed Object

Cell

Value Range and Step

0..255

Unit

Default Value

30

Default Value

Generally, the penalty time of 30s is enough to avoid the ping-pong

Configuration Reason

effect caused by power congestion.

Configuration Rule and


Adjustment Suggestion

It is recommended that the default value be used.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

It is changed to a cell parameter from a power control parameter.


4-547

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.24.18 Power adjustment methods priority 1 (PwrAdjPriority_0)


Full Name

Power adjustment methods priority 1

Abbreviation

PwrAdjPriority_0

3GPP Name

None

3GPP Reference

None
This parameter indicates the congestion control algorithm of priority 1
(highest priority) when congestion control based on power sharing oc-

Description

curs.

Managed Object

Cell
0: Invalid algorithm, no congestion control;
1: Outgoing handover of CS services

Value Range and Step

2: Reduce PDTCH power

Unit

None

Default Value

Default Value

The congestion control algorithm and preference are configured by

Configuration Reason

subscribers.
It is recommended that PwrAdjPriority_0 be configured to handout CS
service, PwrAdjPriority_1 be configured to decrease of PDTCH channel

Configuration Rule and

power, and PwrAdjPriority_2, PwrAdjPriority_3, and PwrAdjPriority_4 be

Adjustment Suggestion

configured to invalid algorithms.


Handout of the CS service has little impact on the voice quality. Decrease
of the PDTCH channel power has certain impact on the PS performance.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

PwrDynShare

Relationship

The parameter takes effect only when the function of dynamic power
sharing is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

4-548
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

It is changed to a cell parameter from a power control parameter.

4.24.19 Power adjustment methods priority2 (PwrAdjPriority_1)


Full Name

Power adjustment methods priority2

Abbreviation

PwrAdjPriority_1

3GPP Name

None

3GPP Reference

None
This parameter indicates the congestion control algorithm of priority 1
(highest priority) when congestion control based on power sharing oc-

Description

curs.

Managed Object

Cell
0: Invalid algorithm, no congestion control;
1: Outgoing handover of CS services

Value Range and Step

2: Reduce PDTCH power

Unit

None

Default Value

Default Value

The congestion control algorithm and preference are configured by

Configuration Reason

subscribers.
It is recommended that PwrAdjPriority_0 be configured to handout CS
service, PwrAdjPriority_1 be configured to decrease of PDTCH channel

Configuration Rule and

power, and PwrAdjPriority_2, PwrAdjPriority_3, and PwrAdjPriority_4 be

Adjustment Suggestion

configured to invalid algorithms.


Handout of the CS service has little impact on the voice quality. Decrease
of the PDTCH channel power has certain impact on the PS performance.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

PwrDynShare

Relationship

The parameter takes effect only when the function of dynamic power
sharing is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-549
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying

It is changed to a cell parameter from a power control parameter, with

Detail

more values.

4.24.20 Power adjustment methods priority3 (PwrAdjPriority_2)


Full Name

Power adjustment methods priority3

Abbreviation

PwrAdjPriority_2

3GPP Name

None

3GPP Reference

None
This parameter indicates the congestion control algorithm of priority 1
(highest priority) when congestion control based on power sharing oc-

Description

curs.

Managed Object

Cell
0: Invalid algorithm, no congestion control;
1: Outgoing handover of CS services

Value Range and Step

2: Reduce PDTCH power

Unit

None

Default Value

Default Value

The congestion control algorithm and preference are configured by

Configuration Reason

subscribers.
It is recommended that PwrAdjPriority_0 be configured to handout CS
service, PwrAdjPriority_1 be configured to decrease of PDTCH channel

Configuration Rule and

power, and PwrAdjPriority_2, PwrAdjPriority_3, and PwrAdjPriority_4 be

Adjustment Suggestion

configured to invalid algorithms.


Handout of the CS service has little impact on the voice quality. Decrease
of the PDTCH channel power has certain impact on the PS performance.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

PwrDynShare

Relationship
Related Interfaces

The parameter takes effect only when the function of dynamic power
sharing is enabled.
None

4-550
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying

It is changed to a cell parameter from a power control parameter, with

Detail

more values.

4.24.21 Power adjustment methods priority4 (PwrAdjPriority_3)


Full Name

Power adjustment methods priority4

Abbreviation

PwrAdjPriority_3

3GPP Name

None

3GPP Reference

None
This parameter indicates the congestion control algorithm of priority 1
(highest priority) when congestion control based on power sharing oc-

Description

curs.

Managed Object

Cell
0: Invalid algorithm, no congestion control;
1: Outgoing handover of CS services

Value Range and Step

2: Reduce PDTCH power

Unit

None

Default Value

Default Value

The congestion control algorithm and preference are configured by

Configuration Reason

subscribers.
It is recommended that PwrAdjPriority_0 be configured to handout CS
service, PwrAdjPriority_1 be configured to decrease of PDTCH channel

Configuration Rule and

power, and PwrAdjPriority_2, PwrAdjPriority_3, and PwrAdjPriority_4 be

Adjustment Suggestion

configured to invalid algorithms.


Handout of the CS service has little impact on the voice quality. Decrease
of the PDTCH channel power has certain impact on the PS performance.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

PwrDynShare

4-551
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

The parameter takes effect only when the function of dynamic power
sharing is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying

It is changed to a cell parameter from a power control parameter, with

Detail

more values.

4.24.22 Power adjustment methods priority5 (PwrAdjPriority_4)


Full Name

Power adjustment methods priority5

Abbreviation

PwrAdjPriority_4

3GPP Name

None

3GPP Reference

None
This parameter indicates the congestion control algorithm of priority 1
(highest priority) when congestion control based on power sharing oc-

Description

curs.

Managed Object

Cell
0: Invalid algorithm, no congestion control;
1: Outgoing handover of CS services

Value Range and Step

2: Reduce PDTCH power

Unit

None

Default Value

Default Value

The congestion control algorithm and preference are configured by

Configuration Reason

subscribers.
It is recommended that PwrAdjPriority_0 be configured to handout CS
service, PwrAdjPriority_1 be configured to decrease of PDTCH channel

Configuration Rule and

power, and PwrAdjPriority_2, PwrAdjPriority_3, and PwrAdjPriority_4 be

Adjustment Suggestion

configured to invalid algorithms.


Handout of the CS service has little impact on the voice quality. Decrease
of the PDTCH channel power has certain impact on the PS performance.

4-552
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

PwrDynShare

Relationship

The parameter takes effect only when the function of dynamic power
sharing is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying

It is changed to a cell parameter from a power control parameter, with

Detail

more values.

4.24.23 Threshold for increase 8PSK power (Inc8PskPwrThs)


Full Name

Threshold for increase 8PSK power

Abbreviation

Inc8PskPwrThs

3GPP Name

None

3GPP Reference

None
This parameter determines whether to increase the power usage threshold of 8PSK. The value 0 indicates that the threshold is not allowed to
be increased. If the iBSC detects that the value of R_BTS2.Inc8PskPwrThs is not 0, it indicates that the interval of increasing or decreasing
the 8PSK power on this RRU or this cell in the RRU exceeds the value of
R_BTS2.Inc8PskPwrDelay. If there are still PDTCH channels for power
increase and the increased power on the RRU does not exceed the value
of R_BTS2.Inc8PskPwrThs, the system increases the 8PSK power for
the PDTCH channel. If the power on the RRU exceeds the value of
R_BTS2.Inc8PskPwrThs+R_BTS2.Inc8PskPwrHys, the system cancels

Description

the power increase this time.

Managed Object

Cell

Value Range and Step

0..100

Unit

4-553
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value
Configuration Reason

By default, this function is disabled. Enable it as required.

Configuration Rule and

This parameter cannot be configured too high, so as to avoid power

Adjustment Suggestion

congestion.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

Inc8PskPwrHys/ PwrAdjustThreshold

Relationship

The value of Inc8PskPwrThs +Inc8PskPwrHys should be smaller than


the value of PwrAdjustThreshold.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.24.24 Hysteresis for increase 8PSK power (Inc8PskPwrHys)


Full Name

Hysteresis for increase 8PSK power

Abbreviation

Inc8PskPwrHys

3GPP Name

None

3GPP Reference

None
This parameter determines whether to increase the delay of 8PSK
power. If the iBSC detects that the value of R_BTS2.Inc8PskPwrThs
is not 0, it indicates that the interval of increasing or decreasing the
8PSK power on this RRU or this cell in the RRU exceeds the value of
R_BTS2.Inc8PskPwrDelay. If there are still PDTCH channels for power
increase and the increased power on the RRU does not exceed the
value of R_BTS2.Inc8PskPwrThs, the system increases the 8PSK power
for the PDTCH channel. If the power on the RRU exceeds the value of
R_BTS2.Inc8PskPwrThs+R_BTS2.Inc8PskPwrHys, the system cancels

Description

the power increase this time.


4-554

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Managed Object

Cell

Value Range and Step

0..100

Unit

Default Value

20

Default Value

The value 20% can generally avoid frequent power increase or

Configuration Reason

restoration.

Configuration Rule and


Adjustment Suggestion

This parameter cannot be configured too low, so as to avoid frequent


power increase or restoration. This parameter cannot be configured too
high, so as to avoid power congestion.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

Inc8PskPwrThs /PwrAdjustThreshold

Relationship

The value of Inc8PskPwrThs +Inc8PskPwrHys should be smaller than


the value of PwrAdjustThreshold

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.24.25 Delay for increase 8PSK power (Inc8PskPwrDelay)


Full Name

Delay for increase 8PSK power

Abbreviation

Inc8PskPwrDelay

3GPP Name

None

3GPP Reference

None

4-555
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines whether to increase the delay time of 8PSK


power. If the iBSC detects that the value of R_BTS2.Inc8PskPwrThs
is not 0, it indicates that the interval of increasing or decreasing the
8PSK power on this RRU or this cell in the RRU exceeds the value of
R_BTS2.Inc8PskPwrDelay. If there are still PDTCH channels for power
increase and the increased power on the RRU does not exceed the value
of R_BTS2.Inc8PskPwrThs, the system increases the 8PSK power for
Description

the PDTCH channel.

Managed Object

Cell

Value Range and Step

5..255

Unit

Default Value

60

Default Value

The value 60s can generally avoid frequent power increase or

Configuration Reason

restoration.

Configuration Rule and

This parameter cannot be configured too low, so as to avoid frequent

Adjustment Suggestion

power increase or restoration.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Cell Power


Parameter

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25 GPRS Resource Control By Service


4.25.1 Threshold of PS resource congestion (PSResourceThr0)
Full Name

Threshold of PS resource congestion


4-556

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Abbreviation

PSResourceThr0

3GPP Name

None

3GPP Reference

None
After the resource control function is enabled based on the classification of
subscriber services, the system controls the maximum number of downlink channels allocated for various types of services when the PS resource

Description

usage in the current cell is higher than this threshold.

Managed Object

Cell

Value Range and Step

2..95

Unit

Default Value

35

Default Value

The maximum number of channels allocated is controlled based on

Configuration Reason

service type when the PS resource usage reaches a certain percentage.


When this parameter is configured to a large value, the system restricts
the maximum number of channels allocated based on service type

Configuration Rule and

when the PS resource usage is relatively high. When this parameter is

Adjustment Suggestion

configured to a small value, the system restricts the maximum number of


channels allocated based on service type when the PS resource usage
is relatively low.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4-557
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

4.25.2 Threshold of relieving PS resource congestion


(PSResourceThr1)
Full Name

Threshold of relieving PS resource congestion

Abbreviation

PSResourceThr1

3GPP Name

None

3GPP Reference

None
After the resource control function is enabled based on the classification of
subscriber services, the system controls the maximum number of downlink channels allocated for various types of services when the PS resource

Description

usage in the current cell is lower than this threshold.

Managed Object

Cell

Value Range and Step

1..90

Unit

Default Value

25

Default Value

The maximum number of channels allocated is not controlled based on

Configuration Reason

service type when the PS resource usage reaches a certain percentage.


When this parameter is configured to a large value, the system does
not restrict the maximum number of channels allocated based on

Configuration Rule and

service type when the PS resource usage is relatively high. When this

Adjustment Suggestion

parameter is configured to a small value, the system does not restrict


the maximum number of channels allocated based on service type when
the PS resource usage is relatively low.

Change Mode

Offline

Related features

None

Related Parameters

PSResourceThr0

Relationship

The value of PSResourceThr1 should be smaller than the value of


PSResourceThr0.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-558
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

New

4.25.3 Scheduled priority of gold user's own service


(SchedulePriority0)
Full Name

Scheduled priority of gold user's own service

Abbreviation

SchedulePriority0

3GPP Name

None

3GPP Reference

None
This parameter determines the scheduled priority of the own service for
gold user. The smaller the value of this parameter, the longer the sched-

Description

uled time for this type of services.

Managed Object

Cell

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For gold subscribers, the own service has a high priority.


The smaller the value of this parameter, the longer the scheduling time
for this type of services. The larger the value of this parameter, the
shorter the scheduling time for this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-559
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

4.25.4 Scheduled priority of silver user's own service


(SchedulePriority1)
Full Name

Scheduled priority of silver user's own service

Abbreviation

SchedulePriority1

3GPP Name

None

3GPP Reference

None
This parameter determines the scheduled priority of the own service for
silver user. The smaller the value of this parameter, the longer the sched-

Description

uled time for this type of services.

Managed Object

Cell

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For silver subscribers, the own service has a high priority.


The smaller the value of this parameter, the longer the scheduling time
for this type of services. The larger the value of this parameter, the
shorter the scheduling time for this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-560
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

New

4.25.5 Scheduled priority of bronze user's own service


(SchedulePriority2)
Full Name

Scheduled priority of bronze user's own service

Abbreviation

SchedulePriority2

3GPP Name

None

3GPP Reference

None
This parameter determines the scheduled priority of the own service for
bronze user. The smaller the value of this parameter, the longer the

Description

scheduled time for this type of services.

Managed Object

Cell

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For copper subscribers, the own service has a high priority.


The smaller the value of this parameter, the longer the scheduling time
for this type of services. The larger the value of this parameter, the
shorter the scheduling time for this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-561
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

4.25.6 Scheduled priority of gold user's browse service


(SchedulePriority3)
Full Name

Scheduled priority of gold user's browse service

Abbreviation

SchedulePriority3

3GPP Name

None

3GPP Reference

None
This parameter determines the scheduled priority of the browse service
for gold user. The smaller the value of this parameter, the longer the

Description

scheduled time for this type of services.

Managed Object

Cell

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For gold subscribers, the browse service has a high priority.


The smaller the value of this parameter, the longer the scheduling time
for this type of services. The larger the value of this parameter, the
shorter the scheduling time for this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-562
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

New

4.25.7 Scheduled priority of silver user's browse service


(SchedulePriority4)
Full Name

Scheduled priority of silver user's browse service

Abbreviation

SchedulePriority4

3GPP Name

None

3GPP Reference

None
This parameter determines the scheduled priority of the browse service
for silver user. The smaller the value of this parameter, the longer the

Description

scheduled time for this type of services.

Managed Object

Cell

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For silver subscribers, the browse service has a high priority.


The smaller the value of this parameter, the longer the scheduling time
for this type of services. The larger the value of this parameter, the
shorter the scheduling time for this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-563
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

4.25.8 Scheduled priority of bronze user's browse service


(SchedulePriority5)
Full Name

Scheduled priority of bronze user's browse service

Abbreviation

SchedulePriority5

3GPP Name

None

3GPP Reference

None
This parameter determines the scheduled priority of the browse service
for bronze user. The smaller the value of this parameter, the longer the

Description

scheduled time for this type of services.

Managed Object

Cell

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For copper subscribers, the browse service has a high priority.


The smaller the value of this parameter, the longer the scheduling time
for this type of services. The larger the value of this parameter, the
shorter the scheduling time for this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-564
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

New

4.25.9 Scheduled priority of gold user's download service


(SchedulePriority6)
Full Name

Scheduled priority of gold user's download service

Abbreviation

SchedulePriority6

3GPP Name

None

3GPP Reference

None
This parameter determines the scheduled priority of the download service
for gold user. The smaller the value of this parameter, the longer the

Description

scheduled time for this type of services.

Managed Object

Cell

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For gold subscribers, the download service has a medium priority.


The smaller the value of this parameter, the longer the scheduling time
for this type of services. The larger the value of this parameter, the
shorter the scheduling time for this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-565
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

4.25.10 Scheduled priority of silver user's download service


(SchedulePriority7)
Full Name

Scheduled priority of silver user's download service

Abbreviation

SchedulePriority7

3GPP Name

None

3GPP Reference

None
This parameter determines the scheduled priority of the download service
for silver user. The smaller the value of this parameter, the longer the

Description

scheduled time for this type of services.

Managed Object

Cell

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For silver subscribers, the download service has a medium priority.


The smaller the value of this parameter, the longer the scheduling time
for this type of services. The larger the value of this parameter, the
shorter the scheduling time for this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-566
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

New

4.25.11 Scheduled priority of bronze user's download service


(SchedulePriority8)
Full Name

Scheduled priority of bronze user's download service

Abbreviation

SchedulePriority8

3GPP Name

None

3GPP Reference

None
This parameter determines the scheduled priority of the download service
for bronze user. The smaller the value of this parameter, the longer the

Description

scheduled time for this type of services.

Managed Object

Cell

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For copper subscribers, the download service has a low priority.


The smaller the value of this parameter, the longer the scheduling time
for this type of services. The larger the value of this parameter, the
shorter the scheduling time for this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-567
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

4.25.12 Scheduled priority of gold user's IM service


(SchedulePriority9)
Full Name

Scheduled priority of gold user's IM service

Abbreviation

SchedulePriority9

3GPP Name

None

3GPP Reference

None
This parameter determines the scheduled priority of the instant messaging (IM) service for gold user. The smaller the value of this parameter, the

Description

longer the scheduled time for this type of services.

Managed Object

Cell

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For gold subscribers, the IM service has the lowest priority.


The smaller the value of this parameter, the longer the scheduling time
for this type of services. The larger the value of this parameter, the
shorter the scheduling time for this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-568
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

New

4.25.13 Scheduled priority of silver user's IM service


(SchedulePriority10)
Full Name

Scheduled priority of silver user's IM service

Abbreviation

SchedulePriority10

3GPP Name

None

3GPP Reference

None
This parameter determines the scheduled priority of the IM service for
silver user. The smaller the value of this parameter, the longer the sched-

Description

uled time for this type of services.

Managed Object

Cell

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For silver subscribers, the IM service has the lowest priority.


The smaller the value of this parameter, the longer the scheduling time
for this type of services. The larger the value of this parameter, the
shorter the scheduling time for this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-569
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

4.25.14 Scheduled priority of bronze user's IM service


(SchedulePriority11)
Full Name

Scheduled priority of bronze user's IM service

Abbreviation

SchedulePriority11

3GPP Name

None

3GPP Reference

None
This parameter determines the scheduled priority of the IM service for
bronze user. The smaller the value of this parameter, the longer the

Description

scheduled time for this type of services.

Managed Object

Cell

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For copper subscribers, the IM service has the lowest priority.


The smaller the value of this parameter, the longer the scheduling time
for this type of services. The larger the value of this parameter, the
shorter the scheduling time for this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-570
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

New

4.25.15 TBF occupancy of gold user's own service (TBFNum0)


Full Name

TBF occupancy of gold user's own service

Abbreviation

TBFNum0

3GPP Name

None

3GPP Reference

None
This parameter determines the TBF usage of the own service for gold
user. The smaller the value of this parameter, the more this type of ser-

Description

vices accessed by the channel.

Managed Object

Cell
1: 0.5 TBF occupancy
2: 1 TBF occupancy

Value Range and Step

3: 2 TBF occupancy

Unit

None

Default Value

Default Value

For gold subscribers, the TBF usage of the own service is not adjusted

Configuration Reason

by default.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the more this type of services
accessed by the channel. The larger the value of this parameter, the
less this type of services accessed by the channel.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-571
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

4.25.16 TBF occupancy of silver user's own service (TBFNum1)


Full Name

TBF occupancy of silver user's own service

Abbreviation

TBFNum1

3GPP Name

None

3GPP Reference

None
This parameter determines the TBF usage of the own service for silver
user. The smaller the value of this parameter, the more this type of ser-

Description

vices accessed by the channel.

Managed Object

Cell
1: 0.5 TBF occupancy
2: 1 TBF occupancy

Value Range and Step

3: 2 TBF occupancy

Unit

None

Default Value

Default Value

For silver subscribers, the TBF usage of the own service is not adjusted

Configuration Reason

by default.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the more this type of services
accessed by the channel. The larger the value of this parameter, the
less this type of services accessed by the channel.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-572
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

New

4.25.17 TBF occupancy of bronze user's own service (TBFNum2)


Full Name

TBF occupancy of bronze user's own service

Abbreviation

TBFNum2

3GPP Name

None

3GPP Reference

None
This parameter determines the TBF usage of the own service for bronze
user. The smaller the value of this parameter, the more this type of ser-

Description

vices accessed by the channel.

Managed Object

Cell
1: 0.5 TBF occupancy
2: 1 TBF occupancy

Value Range and Step

3: 2 TBF occupancy

Unit

None

Default Value

Default Value

For copper subscribers, the TBF usage of the own service is not

Configuration Reason

adjusted by default.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the more this type of services
accessed by the channel. The larger the value of this parameter, the
less this type of services accessed by the channel.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-573
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

4.25.18 TBF occupancy of gold user's browse service (TBFNum3)


Full Name

TBF occupancy of gold user's browse service

Abbreviation

TBFNum3

3GPP Name

None

3GPP Reference

None
This parameter determines the TBF usage of the browse service for gold
user. The smaller the value of this parameter, the more this type of ser-

Description

vices accessed by the channel.

Managed Object

Cell
1: 0.5 TBF occupancy
2: 1 TBF occupancy

Value Range and Step

3: 2 TBF occupancy

Unit

None

Default Value

Default Value

For gold subscribers, the TBF usage of the browse service is not

Configuration Reason

adjusted by default.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the more this type of services
accessed by the channel. The larger the value of this parameter, the
less this type of services accessed by the channel.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-574
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

New

4.25.19 TBF occupancy of silver user's browse service (TBFNum4)


Full Name

TBF occupancy of silver user's browse service

Abbreviation

TBFNum4

3GPP Name

None

3GPP Reference

None
This parameter determines the TBF usage of the browse service for silver user. The smaller the value of this parameter, the more this type of

Description

services accessed by the channel.

Managed Object

Cell
1: 0.5 TBF occupancy
2: 1 TBF occupancy

Value Range and Step

3: 2 TBF occupancy

Unit

None

Default Value

Default Value

For silver subscribers, the TBF usage of the browse service is not

Configuration Reason

adjusted by default.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the more this type of services
accessed by the channel. The larger the value of this parameter, the
less this type of services accessed by the channel.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-575
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

4.25.20 TBF occupancy of bronze user's browse service (TBFNum5)


Full Name

TBF occupancy of bronze user's browse service

Abbreviation

TBFNum5

3GPP Name

None

3GPP Reference

None
This parameter determines the TBF usage of the browse service for
bronze user. The smaller the value of this parameter, the more this type

Description

of services accessed by the channel.

Managed Object

Cell
1: 0.5 TBF occupancy
2: 1 TBF occupancy

Value Range and Step

3: 2 TBF occupancy

Unit

None

Default Value

Default Value

For copper subscribers, the TBF usage of the browse service is not

Configuration Reason

adjusted by default.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the more this type of services
accessed by the channel. The larger the value of this parameter, the
less this type of services accessed by the channel.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-576
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Detail

New

4.25.21 TBF occupancy of gold user's download service (TBFNum6)


Full Name

TBF occupancy of gold user's download service

Abbreviation

TBFNum6

3GPP Name

None

3GPP Reference

None
This parameter determines the TBF usage of the download service for
gold user. The smaller the value of this parameter, the more this type of

Description

services accessed by the channel.

Managed Object

Cell
1: 0.5 TBF occupancy
2: 1 TBF occupancy

Value Range and Step

3: 2 TBF occupancy

Unit

None

Default Value

Default Value

For gold subscribers, the TBF usage of the download service is not

Configuration Reason

adjusted by default.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the more this type of services
accessed by the channel. The larger the value of this parameter, the
less this type of services accessed by the channel.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

4-577
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

4.25.22 TBF occupancy of silver user's download service


(TBFNum7)
Full Name

TBF occupancy of silver user's download service

Abbreviation

TBFNum7

3GPP Name

None

3GPP Reference

None
This parameter determines the TBF usage of the download service for
silver user. The smaller the value of this parameter, the more this type of

Description

services accessed by the channel.

Managed Object

Cell
1: 0.5 TBF occupancy
2: 1 TBF occupancy

Value Range and Step

3: 2 TBF occupancy

Unit

None

Default Value

Default Value

For silver subscribers, the TBF usage of the download service is not

Configuration Reason

adjusted by default.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the more this type of services
accessed by the channel. The larger the value of this parameter, the
less this type of services accessed by the channel.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

4-578
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.23 TBF occupancy of bronze user's download service


(TBFNum8)
Full Name

TBF occupancy of bronze user's download service

Abbreviation

TBFNum8

3GPP Name

None

3GPP Reference

None
This parameter determines the TBF usage of the download service for
bronze user. The smaller the value of this parameter, the more this type

Description

of services accessed by the channel.

Managed Object

Cell
1: 0.5 TBF occupancy
2: 1 TBF occupancy

Value Range and Step

3: 2 TBF occupancy

Unit

None

Default Value

Default Value

For copper subscribers, the TBF usage of the download service is not

Configuration Reason

adjusted by default.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the more this type of services
accessed by the channel. The larger the value of this parameter, the
less this type of services accessed by the channel.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-579
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.24 TBF occupancy of gold user's IM service (TBFNum9)


Full Name

TBF occupancy of gold user's IM service

Abbreviation

TBFNum9

3GPP Name

None

3GPP Reference

None
This parameter determines the TBF usage of the IM service for gold user.
The smaller the value of this parameter, the more this type of services

Description

accessed by the channel.

Managed Object

Cell
1: 0.5 TBF occupancy
2: 1 TBF occupancy

Value Range and Step

3: 2 TBF occupancy

Unit

None

Default Value

Default Value

For gold subscribers, the TBF usage of the IM service is configured

Configuration Reason

relatively low, so as to access more subscribers of this type.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the more this type of services
accessed by the channel. The larger the value of this parameter, the
less this type of services accessed by the channel.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-580
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.25 TBF occupancy of silver user's IM service (TBFNum10)


Full Name

TBF occupancy of silver user's IM service

Abbreviation

TBFNum10

3GPP Name

None

3GPP Reference

None
This parameter determines the TBF usage of the IM service for silver user.
The smaller the value of this parameter, the more this type of services

Description

accessed by the channel.

Managed Object

Cell
1: 0.5 TBF occupancy
2: 1 TBF occupancy

Value Range and Step

3: 2 TBF occupancy

Unit

None

Default Value

Default Value

For silver subscribers, the TBF usage of the IM service is configured

Configuration Reason

relatively low, so as to access more subscribers of this type.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the more this type of services
accessed by the channel. The larger the value of this parameter, the
less this type of services accessed by the channel.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-581
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.26 TBF occupancy of bronze user's IM service (TBFNum11)


Full Name

TBF occupancy of bronze user's IM service

Abbreviation

TBFNum11

3GPP Name

None

3GPP Reference

None
This parameter determines the TBF usage of the IM service for bronze
user. The smaller the value of this parameter, the more this type of ser-

Description

vices accessed by the channel.

Managed Object

Cell
1: 0.5 TBF occupancy
2: 1 TBF occupancy

Value Range and Step

3: 2 TBF occupancy

Unit

None

Default Value

Default Value

For copper subscribers, the TBF usage of the IM service is configured

Configuration Reason

relatively low, so as to access more subscribers of this type.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the more this type of services
accessed by the channel. The larger the value of this parameter, the
less this type of services accessed by the channel.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-582
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.27 Max PDTCH num of gold user's own service in congestion


(MaxPdtchNum0)
Full Name

Max PDTCH num of gold user's own service in congestion

Abbreviation

MaxPdtchNum0

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum number of cells that can be allocated by the own service of gold user when congestion occurs on the

Description

PS service of the cell.

Managed Object

Cell

Value Range and Step

1..5

Unit

None

Default Value

Default Value

The maximum number of allocated channels is not restricted when

Configuration Reason

congestion occurs on the own service of gold subscribers.


The smaller the value of this parameter, the less the number of channels

Configuration Rule and

allocated for this type of services when congestion occurs. The larger

Adjustment Suggestion

the value of this parameter, the more the number of channels allocated
for this type of services when congestion occurs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-583
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.28 Max PDTCH num of silver user's own service in congestion


(MaxPdtchNum1)
Full Name

Max PDTCH num of silver user's own service in congestion

Abbreviation

MaxPdtchNum1

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum number of cells that can be allocated by the own service of silver user when congestion occurs on the

Description

PS service of the cell.

Managed Object

Cell

Value Range and Step

1..5

Unit

None

Default Value

Default Value

The maximum number of allocated channels is not restricted when

Configuration Reason

congestion occurs on the own service of silver subscribers.


The smaller the value of this parameter, the less the number of channels

Configuration Rule and

allocated for this type of services when congestion occurs. The larger

Adjustment Suggestion

the value of this parameter, the more the number of channels allocated
for this type of services when congestion occurs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-584
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.29 Max PDTCH num of bronze user's own service in


congestion (MaxPdtchNum2)
Full Name

Max PDTCH num of bronze user's own service in congestion

Abbreviation

MaxPdtchNum2

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum number of cells that can be allocated by the own service of bronze user when congestion occurs on the

Description

PS service of the cell.

Managed Object

Cell

Value Range and Step

1..5

Unit

None

Default Value

Default Value

The maximum number of allocated channels is not restricted when

Configuration Reason

congestion occurs on the own service of copper subscribers.


The smaller the value of this parameter, the less the number of channels

Configuration Rule and

allocated for this type of services when congestion occurs. The larger

Adjustment Suggestion

the value of this parameter, the more the number of channels allocated
for this type of services when congestion occurs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-585
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.30 Max PDTCH num of gold user's browse service in


congestion (MaxPdtchNum3)
Full Name

Max PDTCH num of gold user's browse service in congestion

Abbreviation

MaxPdtchNum3

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum number of cells that can be allocated by the browse service of gold user when congestion occurs on

Description

the PS service of the cell.

Managed Object

Cell

Value Range and Step

1..5

Unit

None

Default Value

Default Value

The maximum number of allocated channels is not restricted when

Configuration Reason

congestion occurs on the browse service of gold subscribers.


The smaller the value of this parameter, the less the number of channels

Configuration Rule and

allocated for this type of services when congestion occurs. The larger

Adjustment Suggestion

the value of this parameter, the more the number of channels allocated
for this type of services when congestion occurs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-586
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.31 Max PDTCH num of silver user's browse service in


congestion (MaxPdtchNum4)
Full Name

Max PDTCH num of silver user's browse service in congestion

Abbreviation

MaxPdtchNum4

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum number of cells that can be allocated by the browse service of silver user when congestion occurs on

Description

the PS service of the cell.

Managed Object

Cell

Value Range and Step

1..5

Unit

None

Default Value

Default Value

The maximum number of allocated channels is not restricted when

Configuration Reason

congestion occurs on the browse service of silver subscribers.


The smaller the value of this parameter, the less the number of channels

Configuration Rule and

allocated for this type of services when congestion occurs. The larger

Adjustment Suggestion

the value of this parameter, the more the number of channels allocated
for this type of services when congestion occurs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-587
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.32 Max PDTCH num of bronze user's browse service in


congestion (MaxPdtchNum5)
Full Name

Max PDTCH num of bronze user's browse service in congestion

Abbreviation

MaxPdtchNum5

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum number of cells that can be allocated by the browse service of bronze user when congestion occurs on

Description

the PS service of the cell.

Managed Object

Cell

Value Range and Step

1..5

Unit

None

Default Value

Default Value

The maximum number of allocated channels is slightly restricted when

Configuration Reason

congestion occurs on the browse service of copper subscribers.


The smaller the value of this parameter, the less the number of channels

Configuration Rule and

allocated for this type of services when congestion occurs. The larger

Adjustment Suggestion

the value of this parameter, the more the number of channels allocated
for this type of services when congestion occurs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-588
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.33 Max PDTCH num of gold user's download service in


congestion (MaxPdtchNum6)
Full Name

Max PDTCH num of gold user's download service in congestion

Abbreviation

MaxPdtchNum6

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum number of cells that can be allocated by the download service of gold user when congestion occurs on

Description

the PS service of the cell.

Managed Object

Cell

Value Range and Step

1..5

Unit

None

Default Value

Default Value

The maximum number of allocated channels is slightly restricted when

Configuration Reason

congestion occurs on the download service of gold subscribers.


The smaller the value of this parameter, the less the number of channels

Configuration Rule and

allocated for this type of services when congestion occurs. The larger

Adjustment Suggestion

the value of this parameter, the more the number of channels allocated
for this type of services when congestion occurs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-589
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.34 Max PDTCH num of silver user's download service in


congestion (MaxPdtchNum7)
Full Name

Max PDTCH num of silver user's download service in congestion

Abbreviation

MaxPdtchNum7

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum number of cells that can be allocated by the download service of silver user when congestion occurs on

Description

the PS service of the cell.

Managed Object

Cell

Value Range and Step

1..5

Unit

None

Default Value

Default Value

The maximum number of allocated channels is slightly restricted when

Configuration Reason

congestion occurs on the download service of silver subscribers.


The smaller the value of this parameter, the less the number of channels

Configuration Rule and

allocated for this type of services when congestion occurs. The larger

Adjustment Suggestion

the value of this parameter, the more the number of channels allocated
for this type of services when congestion occurs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-590
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.35 Max PDTCH num of bronze user's download service in


congestion (MaxPdtchNum8)
Full Name

Max PDTCH num of bronze user's download service in congestion

Abbreviation

MaxPdtchNum8

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum number of cells that can be allocated by the download service of bronze user when congestion occurs

Description

on the PS service of the cell.

Managed Object

Cell

Value Range and Step

1..5

Unit

None

Default Value

Default Value

The maximum number of allocated channels is slightly restricted when

Configuration Reason

congestion occurs on the download service of copper subscribers.


The smaller the value of this parameter, the less the number of channels

Configuration Rule and

allocated for this type of services when congestion occurs. The larger

Adjustment Suggestion

the value of this parameter, the more the number of channels allocated
for this type of services when congestion occurs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-591
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.36 Max PDTCH num of gold user's IM service in congestion


(MaxPdtchNum9)
Full Name

Max PDTCH num of gold user's IM service in congestion

Abbreviation

MaxPdtchNum9

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum number of cells that can be allocated by the IM service of gold user when congestion occurs on the PS

Description

service of the cell.

Managed Object

Cell

Value Range and Step

1..5

Unit

None

Default Value

Default Value

The maximum number of allocated channels is severely restricted when

Configuration Reason

congestion occurs on the IM service of gold subscribers.


The smaller the value of this parameter, the less the number of channels

Configuration Rule and

allocated for this type of services when congestion occurs. The larger

Adjustment Suggestion

the value of this parameter, the more the number of channels allocated
for this type of services when congestion occurs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-592
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.37 Max PDTCH num of silver user's IM service in congestion


(MaxPdtchNum10)
Full Name

Max PDTCH num of silver user's IM service in congestion

Abbreviation

MaxPdtchNum10

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum number of cells that can be allocated by the IM service of silver user when congestion occurs on the

Description

PS service of the cell.

Managed Object

Cell

Value Range and Step

1..5

Unit

None

Default Value

Default Value

The maximum number of allocated channels is severely restricted when

Configuration Reason

congestion occurs on the IM service of silver subscribers.


The smaller the value of this parameter, the less the number of channels

Configuration Rule and

allocated for this type of services when congestion occurs. The larger

Adjustment Suggestion

the value of this parameter, the more the number of channels allocated
for this type of services when congestion occurs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-593
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.38 Max PDTCH num of bronze user's IM service in congestion


(MaxPdtchNum11)
Full Name

Max PDTCH num of bronze user's IM service in congestion

Abbreviation

MaxPdtchNum11

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum number of cells that can be allocated by the IM service of bronze user when congestion occurs on the

Description

PS service of the cell.

Managed Object

Cell

Value Range and Step

1..5

Unit

None

Default Value

Default Value

The maximum number of allocated channels is severely restricted when

Configuration Reason

congestion occurs on the IM service of copper subscribers.


The smaller the value of this parameter, the less the number of channels

Configuration Rule and

allocated for this type of services when congestion occurs. The larger

Adjustment Suggestion

the value of this parameter, the more the number of channels allocated
for this type of services when congestion occurs.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-594
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.39 Downlink delay time of gold user's own service


(DlDelayTimeOfService0)
Full Name

Downlink delay time of gold user's own service

Abbreviation

DlDelayTimeOfService0

3GPP Name

None

3GPP Reference

None
This parameter determines the delay time of the own service for gold user

Description

after the downlink TBF data is completely transmitted.

Managed Object

Cell

Value Range and Step

50..4000

Unit

ms

Default Value

2000

Default Value

According to the service characteristics, the delay time of the own

Configuration Reason

service for gold subscribers is relatively long.


The smaller the value of this parameter, the shorter the delay time for

Configuration Rule and

this type of services after the TBF data is completely transmitted. The

Adjustment Suggestion

larger the value of this parameter, the longer the delay time for this type
of services after the TBF data is completely transmitted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-595
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.40 Downlink delay time of silver user's own service


(DlDelayTimeOfService1)
Full Name

Downlink delay time of silver user's own service

Abbreviation

DlDelayTimeOfService1

3GPP Name

None

3GPP Reference

None
This parameter determines the delay time of the own service for silver

Description

user after the downlink TBF data is completely transmitted.

Managed Object

Cell

Value Range and Step

50..4000

Unit

ms

Default Value

2000

Default Value

According to the service characteristics, the delay time of the own

Configuration Reason

service for silver subscribers is relatively long.


The smaller the value of this parameter, the shorter the delay time for

Configuration Rule and

this type of services after the TBF data is completely transmitted. The

Adjustment Suggestion

larger the value of this parameter, the longer the delay time for this type
of services after the TBF data is completely transmitted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-596
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.41 Downlink delay time of bronze user's own service


(DlDelayTimeOfService2)
Full Name

Downlink delay time of bronze user's own service

Abbreviation

DlDelayTimeOfService2

3GPP Name

None

3GPP Reference

None
This parameter determines the delay time of the own service for bronze

Description

user after the downlink TBF data is completely transmitted.

Managed Object

Cell

Value Range and Step

50..4000

Unit

ms

Default Value

2000

Default Value

According to the service characteristics, the delay time of the own

Configuration Reason

service for copper subscribers is relatively long.


The smaller the value of this parameter, the shorter the delay time for

Configuration Rule and

this type of services after the TBF data is completely transmitted. The

Adjustment Suggestion

larger the value of this parameter, the longer the delay time for this type
of services after the TBF data is completely transmitted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-597
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.42 Downlink delay time of gold user's browse service


(DlDelayTimeOfService3)
Full Name

Downlink delay time of gold user's browse service

Abbreviation

DlDelayTimeOfService3

3GPP Name

None

3GPP Reference

None
This parameter determines the delay time of the browse service for gold

Description

user after the downlink TBF data is completely transmitted.

Managed Object

Cell

Value Range and Step

50..4000

Unit

ms

Default Value

2000

Default Value

According to the service characteristics, the delay time of the browse

Configuration Reason

service for gold subscribers is relatively long.


The smaller the value of this parameter, the shorter the delay time for

Configuration Rule and

this type of services after the TBF data is completely transmitted. The

Adjustment Suggestion

larger the value of this parameter, the longer the delay time for this type
of services after the TBF data is completely transmitted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-598
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.43 Downlink delay time of silver user's browse service


(DlDelayTimeOfService4)
Full Name

Downlink delay time of silver user's browse service

Abbreviation

DlDelayTimeOfService4

3GPP Name

None

3GPP Reference

None
This parameter determines the delay time of the browse service for silver

Description

user after the downlink TBF data is completely transmitted.

Managed Object

Cell

Value Range and Step

50..4000

Unit

ms

Default Value

2000

Default Value

According to the service characteristics, the delay time of the browse

Configuration Reason

service for silver subscribers is relatively long.


The smaller the value of this parameter, the shorter the delay time for

Configuration Rule and

this type of services after the TBF data is completely transmitted. The

Adjustment Suggestion

larger the value of this parameter, the longer the delay time for this type
of services after the TBF data is completely transmitted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-599
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.44 Downlink delay time of bronze user's browse service


(DlDelayTimeOfService5)
Full Name

Downlink delay time of bronze user's browse service

Abbreviation

DlDelayTimeOfService5

3GPP Name

None

3GPP Reference

None
This parameter determines the delay time of the browse service for bronze

Description

user after the downlink TBF data is completely transmitted.

Managed Object

Cell

Value Range and Step

50..4000

Unit

ms

Default Value

2000

Default Value

According to the service characteristics, the delay time of the browse

Configuration Reason

service for copper subscribers is relatively long.


The smaller the value of this parameter, the shorter the delay time for

Configuration Rule and

this type of services after the TBF data is completely transmitted. The

Adjustment Suggestion

larger the value of this parameter, the longer the delay time for this type
of services after the TBF data is completely transmitted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-600
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.45 Downlink delay time of gold user's download service


(DlDelayTimeOfService6)
Full Name

Downlink delay time of gold user's download service

Abbreviation

DlDelayTimeOfService6

3GPP Name

None

3GPP Reference

None
This parameter determines the delay time of the download service for gold

Description

user after the downlink TBF data is completely transmitted.

Managed Object

Cell

Value Range and Step

50..4000

Unit

ms

Default Value

2000

Default Value

According to the service characteristics, the delay time of the download

Configuration Reason

service for gold subscribers is relatively long.


The smaller the value of this parameter, the shorter the delay time for

Configuration Rule and

this type of services after the TBF data is completely transmitted. The

Adjustment Suggestion

larger the value of this parameter, the longer the delay time for this type
of services after the TBF data is completely transmitted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-601
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.46 Downlink delay time of silver user's download service


(DlDelayTimeOfService7)
Full Name

Downlink delay time of silver user's download service

Abbreviation

DlDelayTimeOfService7

3GPP Name

None

3GPP Reference

None
This parameter determines the delay time of the download service for

Description

silver user after the downlink TBF data is completely transmitted.

Managed Object

Cell

Value Range and Step

50..4000

Unit

ms

Default Value

2000

Default Value

According to the service characteristics, the delay time of the download

Configuration Reason

service for silver subscribers is relatively long.


The smaller the value of this parameter, the shorter the delay time for

Configuration Rule and

this type of services after the TBF data is completely transmitted. The

Adjustment Suggestion

larger the value of this parameter, the longer the delay time for this type
of services after the TBF data is completely transmitted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-602
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.47 Downlink delay time of bronze user's download service


(DlDelayTimeOfService8)
Full Name

Downlink delay time of bronze user's download service

Abbreviation

DlDelayTimeOfService8

3GPP Name

None

3GPP Reference

None
This parameter determines the delay time of the download service for

Description

bronze user after the downlink TBF data is completely transmitted.

Managed Object

Cell

Value Range and Step

50..4000

Unit

ms

Default Value

2000

Default Value

According to the service characteristics, the delay time of the download

Configuration Reason

service for copper subscribers is relatively long.


The smaller the value of this parameter, the shorter the delay time for

Configuration Rule and

this type of services after the TBF data is completely transmitted. The

Adjustment Suggestion

larger the value of this parameter, the longer the delay time for this type
of services after the TBF data is completely transmitted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-603
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.48 Downlink delay time of gold user's IM service


(DlDelayTimeOfService9)
Full Name

Downlink delay time of gold user's IM service

Abbreviation

DlDelayTimeOfService9

3GPP Name

None

3GPP Reference

None
This parameter determines the delay time of the IM service for gold user

Description

after the downlink TBF data is completely transmitted.

Managed Object

Cell

Value Range and Step

50..4000

Unit

ms

Default Value

500

Default Value

According to the service characteristics, the delay time of the IM service

Configuration Reason

for gold subscribers is relatively short.


The smaller the value of this parameter, the shorter the delay time for

Configuration Rule and

this type of services after the TBF data is completely transmitted. The

Adjustment Suggestion

larger the value of this parameter, the longer the delay time for this type
of services after the TBF data is completely transmitted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-604
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.49 Downlink delay time of silver user's IM service


(DlDelayTimeOfService10)
Full Name

Downlink delay time of silver user's IM service

Abbreviation

DlDelayTimeOfService10

3GPP Name

None

3GPP Reference

None
This parameter determines the delay time of the IM service for silver user

Description

after the downlink TBF data is completely transmitted.

Managed Object

Cell

Value Range and Step

50..4000

Unit

ms

Default Value

500

Default Value

According to the service characteristics, the delay time of the IM service

Configuration Reason

for silver subscribers is relatively short.


The smaller the value of this parameter, the shorter the delay time for

Configuration Rule and

this type of services after the TBF data is completely transmitted. The

Adjustment Suggestion

larger the value of this parameter, the longer the delay time for this type
of services after the TBF data is completely transmitted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-605
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.50 Downlink delay time of bronze user's IM service


(DlDelayTimeOfService11)
Full Name

Downlink delay time of bronze user's IM service

Abbreviation

DlDelayTimeOfService11

3GPP Name

None

3GPP Reference

None
This parameter determines the delay time of the IM service for bronze

Description

user after the downlink TBF data is completely transmitted.

Managed Object

Cell

Value Range and Step

50..4000

Unit

ms

Default Value

500

Default Value

According to the service characteristics, the delay time of the IM service

Configuration Reason

for copper subscribers is relatively short.


The smaller the value of this parameter, the shorter the delay time for

Configuration Rule and

this type of services after the TBF data is completely transmitted. The

Adjustment Suggestion

larger the value of this parameter, the longer the delay time for this type
of services after the TBF data is completely transmitted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-606
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.51 Preemption priority of gold user's own service


(PreemptPriority0)
Full Name

Preemption priority of gold user's own service

Abbreviation

PreemptPriority0

3GPP Name

None

3GPP Reference

None
This parameter determines the preempt priority of the own service for
gold user. The larger the value of this parameter, the higher the preempt
priority and thus the higher the possibility of preempting resources in case

Description

of insufficient resources.

Managed Object

Cell

Value Range and Step

0..11

Unit

None

Default Value

11

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For gold subscribers, the own service has a high preempt priority.
The smaller the value of this parameter, the lower the preempt priority of
this type of services. The larger the value of this parameter, the higher
the preempt priority of this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-607
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.52 Preemption priority of silver user's own service


(PreemptPriority1)
Full Name

Preemption priority of silver user's own service

Abbreviation

PreemptPriority1

3GPP Name

None

3GPP Reference

None
This parameter determines the preempt priority of the own service for
silver user. The larger the value of this parameter, the higher the preempt
priority and thus the higher the possibility of preempting resources in case

Description

of insufficient resources.

Managed Object

Cell

Value Range and Step

0..11

Unit

None

Default Value

50

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For silver subscribers, the own service has a high preempt priority.
The smaller the value of this parameter, the lower the preempt priority of
this type of services. The larger the value of this parameter, the higher
the preempt priority of this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-608
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.53 Preemption priority of bronze user's own service


(PreemptPriority2)
Full Name

Preemption priority of bronze user's own service

Abbreviation

PreemptPriority2

3GPP Name

None

3GPP Reference

None
This parameter determines the preempt priority of the own service for
bronze user. The larger the value of this parameter, the higher the preempt priority and thus the higher the possibility of preempting resources

Description

in case of insufficient resources.

Managed Object

Cell

Value Range and Step

0..11

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For copper subscribers, the own service has a medium preempt priority.
The smaller the value of this parameter, the lower the preempt priority of
this type of services. The larger the value of this parameter, the higher
the preempt priority of this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-609
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.54 Preemption priority of gold user's browse service


(PreemptPriority3)
Full Name

Preemption priority of gold user's browse service

Abbreviation

PreemptPriority3

3GPP Name

None

3GPP Reference

None
This parameter determines the preempt priority of the browse service for
gold user. The larger the value of this parameter, the higher the preempt
priority and thus the higher the possibility of preempting resources in case

Description

of insufficient resources.

Managed Object

Cell

Value Range and Step

0..11

Unit

None

Default Value

10

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For gold subscribers, the browse service has a high preempt priority.
The smaller the value of this parameter, the lower the preempt priority of
this type of services. The larger the value of this parameter, the higher
the preempt priority of this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-610
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.55 Preemption priority of silver user's browse service


(PreemptPriority4)
Full Name

Preemption priority of silver user's browse service

Abbreviation

PreemptPriority4

3GPP Name

None

3GPP Reference

None
This parameter determines the preempt priority of the browse service for
silver user. The larger the value of this parameter, the higher the preempt
priority and thus the higher the possibility of preempting resources in case

Description

of insufficient resources.

Managed Object

Cell

Value Range and Step

0..11

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For silver subscribers, the browse service has a high preempt priority.
The smaller the value of this parameter, the lower the preempt priority of
this type of services. The larger the value of this parameter, the higher
the preempt priority of this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-611
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.56 Preemption priority of bronze user's browse service


(PreemptPriority5)
Full Name

Preemption priority of bronze user's browse service

Abbreviation

PreemptPriority5

3GPP Name

None

3GPP Reference

None
This parameter determines the preempt priority of the browse service for
bronze user. The larger the value of this parameter, the higher the preempt priority and thus the higher the possibility of preempting resources

Description

in case of insufficient resources.

Managed Object

Cell

Value Range and Step

0..11

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For copper subscribers, the browse service has a high preempt priority.
The smaller the value of this parameter, the lower the preempt priority of
this type of services. The larger the value of this parameter, the higher
the preempt priority of this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-612
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.57 Preemption priority of gold user's download service


(PreemptPriority6)
Full Name

Preemption priority of gold user's download service

Abbreviation

PreemptPriority6

3GPP Name

None

3GPP Reference

None
This parameter determines the preempt priority of the download service
for gold user. The larger the value of this parameter, the higher the preempt priority and thus the higher the possibility of preempting resources

Description

in case of insufficient resources.

Managed Object

Cell

Value Range and Step

0..11

Unit

None

Default Value

Default Value

For gold subscribers, the download service has a medium preempt

Configuration Reason

priority.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the lower the preempt priority of
this type of services. The larger the value of this parameter, the higher
the preempt priority of this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-613
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.58 Preemption priority of silver user's download service


(PreemptPriority7)
Full Name

Preemption priority of silver user's download service

Abbreviation

PreemptPriority7

3GPP Name

None

3GPP Reference

None
This parameter determines the preempt priority of the download service
for silver user. The larger the value of this parameter, the higher the preempt priority and thus the higher the possibility of preempting resources

Description

in case of insufficient resources.

Managed Object

Cell

Value Range and Step

0..11

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For silver subscribers, the download service has a high preempt priority.
The smaller the value of this parameter, the lower the preempt priority of
this type of services. The larger the value of this parameter, the higher
the preempt priority of this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-614
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.59 Preemption priority of bronze user's download service


(PreemptPriority8)
Full Name

Preemption priority of bronze user's download service

Abbreviation

PreemptPriority8

3GPP Name

None

3GPP Reference

None
This parameter determines the preempt priority of the download service
for bronze user. The larger the value of this parameter, the higher the preempt priority and thus the higher the possibility of preempting resources

Description

in case of insufficient resources.

Managed Object

Cell

Value Range and Step

0..11

Unit

None

Default Value

Default Value

For copper subscribers, the download service has a high preempt

Configuration Reason

priority.

Configuration Rule and


Adjustment Suggestion

The smaller the value of this parameter, the lower the preempt priority of
this type of services. The larger the value of this parameter, the higher
the preempt priority of this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-615
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.60 Preemption priority of gold user's IM service


(PreemptPriority9)
Full Name

Preemption priority of gold user's IM service

Abbreviation

PreemptPriority9

3GPP Name

None

3GPP Reference

None
This parameter determines the preempt priority of the IM service for gold
user. The larger the value of this parameter, the higher the preempt priority and thus the higher the possibility of preempting resources in case

Description

of insufficient resources.

Managed Object

Cell

Value Range and Step

0..11

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For gold subscribers, the IM service has a low priority.


The smaller the value of this parameter, the lower the preempt priority of
this type of services. The larger the value of this parameter, the higher
the preempt priority of this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-616
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.61 Preemption priority of silver user's IM service


(PreemptPriority10)
Full Name

Preemption priority of silver user's IM service

Abbreviation

PreemptPriority10

3GPP Name

None

3GPP Reference

None
This parameter determines the preempt priority of the IM service for silver
user. The larger the value of this parameter, the higher the preempt priority and thus the higher the possibility of preempting resources in case

Description

of insufficient resources.

Managed Object

Cell

Value Range and Step

0..11

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For silver subscribers, the IM service has a low priority.


The smaller the value of this parameter, the lower the preempt priority of
this type of services. The larger the value of this parameter, the higher
the preempt priority of this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-617
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4.25.62 Preemption priority of bronze user's IM service


(PreemptPriority11)
Full Name

Preemption priority of bronze user's IM service

Abbreviation

PreemptPriority11

3GPP Name

None

3GPP Reference

None
This parameter determines the preempt priority of the IM service for
bronze user. The larger the value of this parameter, the higher the preempt priority and thus the higher the possibility of preempting resources

Description

in case of insufficient resources.

Managed Object

Cell

Value Range and Step

0..11

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

For copper subscribers, the IM service has a low priority.


The smaller the value of this parameter, the lower the preempt priority of
this type of services. The larger the value of this parameter, the higher
the preempt priority of this type of services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

4-618
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 4 Cell Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->GPRS Resource


Control By Service

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

4-619
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This page intentionally left blank.

4-620
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5

Cell Object Parameters


Table of Contents
TRX Parameters ........................................................................................................5-1
Power Control Parameters .......................................................................................5-41
Handover Control Parameters ................................................................................5-214
SDCCH Handover Control Parameters...................................................................5-459
UTRAN Handover Control Parameters ...................................................................5-533
UTRAN Cell Control Parameters ............................................................................5-582
Adjacent Cell Parameters.......................................................................................5-663
Frequency Hopping System Parameters ................................................................5-805
PS Handover Control Parameters ..........................................................................5-812
LTE Cell Control Parameters ..................................................................................5-888
LTE Cell Reselection Parameters ...........................................................................5-917
VPC Cell Parameters .............................................................................................5-933
Site Parameters .....................................................................................................5-939

5.1 TRX Parameters


TRX parameters are divided into two sub-interfaces. If the site is IP access point, the TRX
information interface will add IP Parameters sub-interface.

5.1.1 TRX Information Parameters


5.1.1.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None

Description

This parameter means the site ID. It cannot be modified.


Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None

Default Value

5-1
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path


Parameter

Modifying

Version
Parameter

ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX

None
Modifying

Detail

None

5.1.1.2 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell
1 ~ 24
The following lists the maximum number of BtsIds of each site type.

Value Range and Step

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6
5-2

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

M8206: 6

B8018: 6

S8001: 1

SDR: 24

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path


Parameter

Modifying

Version
Parameter

ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX

None
Modifying

Detail

None

5.1.1.3 TRX ID (TrxId)


Full Name

TRX ID

Abbreviation

TrxId

3GPP Name

None

3GPP Reference

None
This parameter indicates the TRX number in the cell. According to
GSMspecifications, one cell can have 64 carriers at most.

Description

The number should be consistent with the carrier number of SDR.

Managed Object

TRX

5-3
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

1..60
The maximum value of TrxId for each site type is as follows:
OB06: 48
BS20: 48
BS21: 48
BS21V20: 48
BS30: 48
BS30V12: 48
B8112: 54
M8202: 54
M8206: 54
B8018: 54
S8001: 1
Value Range and Step

SDR: 60

Unit

None

Default Value

Sort the numbers.

Default Value

The OMC can generate these numbers sequentially and they do not

Configuration Reason

need sorting.

Configuration Rule and

The OMC can generate these numbers sequentially and they do not

Adjustment Suggestion

need sorting.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.1.4 Subcell ID (SubCellId)


Full Name

Subcell ID
5-4

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Abbreviation

SubCellId

3GPP Name

None

3GPP Reference

None
This parameter indicates the subcell ID that the carrier frequency belongs

Description

to. It cannot be modified after created.

Managed Object

TRX
When the option "Use sub-cell (SubCellUsed)" is "No", the value range
is First Subcell;
When the option "Use sub-cell (SubCellUsed)" is "Yes", the value range

Value Range and Step

is First Subcell, Second Subcell;

Unit

None

Default Value

First Subcell

Default Value
Configuration Reason

Usually the carrier frequency configured belongs to the first subcell.

Configuration Rule and

The carrier frequency that belongs to the second subcell needs to be

Adjustment Suggestion

modified.

Change Mode

Offline

Related features

ZGO-04-02-005 Co-BCCH

Related Parameters

[Cell]SubCellUsed

Relationship

The value of the "SubCellUsed" parameter impacts the value range of


this parameter.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.1.5 RTTI preference (RTTIPrefer)


Full Name

RTTI preference

Abbreviation

RTTIPrefer
5-5

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether the carrier is preferentially selected by
the RTTI MS. If the carrier is, the MS supporting RTTI allocates the carrier
to perform services when it establishes RTTI TBF. If the MS that does not
support RTTI performs the PS service, the carrier is selected to allocate

Description

only if no other carriers can be allocated.

Managed Object

TRX

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional parameter, which is not configured by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]Info_4_3
[TRX]INFO1_4_3

Relationship

This parameter is valid after the BSC-level switch and cell-level switch
with RTTIfunction are enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.1.6 Combiner Loss CombinerLoss,dB)


Full Name

Combiner Loss

Abbreviation

CombinerLoss

3GPP Name

None
5-6

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Reference

None

Description

This parameter determines the combiner loss of the carrier.

Managed Object

TRX

Value Range and Step

0..48, Step: 1

Unit

dB

Default Value

Default Value
Configuration Reason

This parameter is configured according to the actual condition.

Configuration Rule and

It is required to configure this parameter according to the actual

Adjustment Suggestion

combiner loss of the carrier.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->IP


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.1.1.7 TRX type (TrxType)


Full Name

TRX type

Abbreviation

TrxType

3GPP Name

None

3GPP Reference

None

5-7
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Common TRX is applied for common cell. extended TRX is applied


for extended cell.
In common cell, TRX Type shall be configured as Normal TRX;
In an extended cell without subcell support, the transceiver type should
be extended TRX; in an extended cell with subcell support, the subcell1
Description

should be set as extended TRX and subcell2 set is free.

Managed Object

TRX
1..2
1. Common TRX
2. Extended TRX

Value Range and Step

Step: 1

Unit

None

Default Value

Common TRX

Default Value
Configuration Reason

This parameter has a fixed configuration.

Configuration Rule and


Adjustment Suggestion

This parameter has a fixed configuration.

Change Mode

Offline

Related features

ZGO-04-01-001 Extended Cell Coverage

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.1.8 Assign Priority of the Trx (TrxPriority)


Full Name

Assign Priority of the Trx

Abbreviation

TrxPriority

5-8
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

None

3GPP Reference

None
This parameter describes priorities for allocating carriers of the same type.
1 represents the highest priority. Select channels on carriers with high

Description

priority when allocating CSchannels.

Managed Object

TRX
1..5

Value Range and Step

Step: 1

Unit

None
When BCCH carrier (BcchMark) parameter value is "No", the default
will be 3;
When BCCH carrier (BcchMark) parameter value is "Yes", the default

Default Value

will be 1.

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The common carriers takes lower priority than BCCH carrier.


The CS channel allocation refers to carrier priority. The common carriers
takes lower priority than BCCH carrier. If some carriers need to accept
the CS traffic, level up their priorities.

Change Mode

Offline

Related features

ZGO-03-02-002 Enhancement on Channel Allocation

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.1.9 BCCH carrier frequency (BcchMark)


Full Name

BCCH carrier frequency

5-9
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

BcchMark

3GPP Name

None

3GPP Reference

None
One BCCH carrier frequency must be configured in a cell and it should

Description

be the only one.

Managed Object

TRX
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

The fixed attributes generated when the BCCH carrier has been

Configuration Reason

configured.

Configuration Rule and


Adjustment Suggestion

No need to modify.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.1.10 Static power level (PwRreduction)


Full Name

Static power level

Abbreviation

PwRreduction

3GPP Name

None

3GPP Reference

None

5-10
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter represents the static power level of a transceiver. Usually


a static power control is added to the basis of TRX transmission power
level specified by PowerClass parameter. Namely, a restriction is added
to the maximum transmission power to get an actual maximum transmission power Pn used by the TRX. The dynamic power control is implemented based on the maximum transmission power Pn. This parameter
Description

is invalid for SDR site.

Managed Object

TRX
Max output power,Max output power -2 dB,Max output power -4 dB,Max
output power -6 dB,Max output power -8 dB,Max output power -10 dB,Max
output power -12 dB,Max output power +3 dB, Max output power +2.5 dB,
Max output power +2 dB, Max output power +1.5 dB,Max output power

Value Range and Step

+1 dB,Max output power +0.5 dB

Unit

None

Default Value

Maximum output power

Default Value
Configuration Reason

The maximum output power takes the highest priority.


The static power in a weak coverage cell can be set high to reduce call
drops and improve voice quality.
The static power in a over-coverage cell can be reduced by 2-4 dB to
decrease inner-radio-network interference and improve voice quality.

Configuration Rule and


Adjustment Suggestion

The transmission power for a severe over-coverage cell can be reduced


by 2-6 dB, and the configurations for all the carrier frequencies in a cell
should be consistent.
In a wide coverage area or a village, the static power level can be
set high to raise the success ratio of SD/TCH assignments, then
the coverage ratio and the success ratio of core network paging are
improved. For SDR site, this parameter needs to be adjusted on OMCB.

Change Mode

Offline

Related features

ZGB-04-02-002 Static BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX

5-11
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.1.11 Power level (PowerClass)


Full Name

Power level

Abbreviation

PowerClass

3GPP Name

power class(45.005)

3GPP Reference

45.005
This parameter indicates the power level of carrier. The value can be
converted to an actual power value used to calculate path loss and CI

Description

value in measurement report.

Managed Object

TRX
1..8 The power level corresponds with the transmission power in the
following relations:
1: 49 dBm
2: 49 dBm
3: 49 dBm
4: 49 dBm
5: 49 dBm

Value Range and Step

6, 7, 8: 46 dBm

Unit

None

Default Value

Default Value
Configuration Reason

The level 3 carrier is frequently used.

Configuration Rule and

Set this parameter according to the BTS configuration. The combiner

Adjustment Suggestion

loss should also be considered.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um, Abis

Impact on Equipment

Impact on service

5-12
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.1.12 Support FHS (SupportFHS)


Full Name

Support FHS

Abbreviation

SupportFHS

3GPP Name

hopping

3GPP Reference

3GPP TS 44.018
This parameter indicates whether frequency-hopping is supported.
When this parameter is set as 'Base band freqhop', 'BhGroupId' is
added to the interface. When this parameter is set as 'RFID freqhop',
'Frequency' disappears from the interface and 'FhsId' is added to the
interface.
Note: S8001 just has one frequency, and does not support frequency

Description

hopping.

Managed Object

TRX
When "BcchMark" is "No", the value range is "No", "Base band freqhop",
and "RFID freqhop".
When "BcchMark" is "Yes", the value range is "No" and "Base band

Value Range and Step

freqhop".

Unit

None

Default Value

No

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline
ZGO-04-03-001 Synthesized Frequency Hopping

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

None

Relationship

None

5-13
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.1.13 TRX baseband- hopping group number (TRXBHGROUP)


Full Name

TRX baseband- hopping group number

Abbreviation

TRXBHGROUP

3GPP Name

None

3GPP Reference

None
When the base band frequency hopping is configured, choose the ID of
frequency hopping group with base band frequency hopping. If there are
multiple transceivers configured with then same frequency hopping group
ID, the frequency points of these transceivers will be added to the systems
marked in the groups. The frequency hopping will use the same MA fre-

Description

quency point list.

Managed Object

TRX

Value Range and Step

1..255

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

None

Relationship

None

Related Interfaces

None
5-14

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.1.14 Frequency hopping ID (FhsId)


Full Name

Frequency hopping ID

Abbreviation

FhsId

3GPP Name

None

3GPP Reference

None

Description

This parameter identifies the frequency hopping system.

Managed Object

Cell

Value Range and Step

1..255

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and

This parameter should be configured according to the radio network

Adjustment Suggestion

planning.

Change Mode

Offline

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

ZGO-04-03-001 Synthesized Frequency Hopping

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX
5-15

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.1.15 Frequency (Frequency)


Full Name

Frequency

Abbreviation

Frequency

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the frequency point of this transceiver.

Managed Object

TRX
TCH frequency point can reside on a different frequency band with
BCCH frequency point. The following describes the value range of the
frequency point:
Frequency band (FreqBand) is GSM900: 1 .. 124;
Frequency band (FreqBand) is EXT900: 0 .. 124, 975 .. 1023;
Frequency band (FreqBand) is DCS1800: 512 .. 885;
Frequency band (FreqBand) is PCS1900: 512 .. 810;
Frequency band (FreqBand) is GSM850: 128 .. 251
The TCH transceiver frequency point is not correlated with the FreqBand
parameter. The following describes the value range of frequency band:
TCH transceiver locates in GSM900 frequency band: 1 .. 124;
TCH transceiver locates in EXT900 frequency band: 0 .. 124, 975 ..
1023;
TCH transceiver locates in DCS1800 frequency band: 512 .. 885;
TCH transceiver locates in PCS1900 frequency band: 512 .. 810;

Value Range and Step

TCH transceiver locates in GSM850 frequency band: 128 .. 251;

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline
ZGO-04-03-001 Synthesized Frequency Hopping

Related features

ZGO-04-03-004 Baseband Frequency Hopping

5-16
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.2 Channel Information Parameters


5.1.2.1 Channel ID (Channel ID)
Full Name

Channel ID

Abbreviation

Channel ID

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the number to identify timeslot.

Managed Object

TS
When "TRX type (TrxType)" is "Common TRX", eight timeslot numbers
are displayed on the interface, that is, 0, 1, 2, 3, 4, 5, 6, 7.
When "TRX type (TrxType)" is "Extended TRX", four timeslot numbers

Value Range and Step

are displayed on the interface, that is, 0, 2, 4, 6.

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline

Related features

None

5-17
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->Channel

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Info
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.2.2 TS Channel Combination (TS Channel Combination)


Full Name

TS Channel Combination

Abbreviation

TS Channel Combination

3GPP Name

None

3GPP Reference

None
This parameter defines the combined types of timeslot channel.
Correlation with some parameters is as follows:
Cell broadcast short message (SmsCbUsed) supported:
If "CBC Supported (SmsCbUsed)" is "No", that is, CBC is not supported,
the system automatically finds all timeslot channel combinations in the
cell. If CBC channel exists, it is changed to SDCCH.
If "CBC Supported (SmsCbUsed)" is "Yes", that is, CBC is supported,
the system automatically finds all timeslot channel combinations in
the cell. If a non-BCCH channel is found for a carrier, it is changed to
SDCCH+CBCH.
GPRS service supported (PsSupport):
If "GPRS Supported (PsSupport)" is "No", that is, GPRS is not supported,
the system automatically changes all timeslot channels whose type is
PS in the cell to TCH.
Common control channel configuration (CcchConf):
If CcchConf is configured as "CCCH uses one physical channel,
combined with SDCCH", then in the channel parameters, channel
combination of timeslot 0 must be one of the following two combinations:

Description

"BCCH+SDCCH/4" and "BCCH+SDCCH/4+CBCH".


5-18

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

When CcchConf is configured as "CCCH uses one physical channel,


not combined with SDCCH", then in the channel parameters, channel
combination of timeslot 0 must be one of the following two combinations:
"FCCH+SCH+BCCH+CCCH" and "BCCH+CCCH".
When CcchConf is configured as "CCCH uses two physical channel,
not combined with SDCCH", then in the channel parameters, channel
combination of timeslot 0 and timeslot 2 is one of the following two
combinations: "FCCH+SCH+BCCH+CCCH" and "BCCH+CCCH".
When CcchConf is configured as "CCCH uses three physical channel,
not combined with SDCCH", then in the channel parameters, channel
combination of timeslot 0, 2, and 4 is one of the following two
combinations: "FCCH+SCH+BCCH+CCCH" and "BCCH+CCCH".
When CcchConf is configured as "CCCH uses four physical channel,
not combined with SDCCH", then in the channel parameters, channel
combination of timeslot 0, 2, 4, and 6 is one of the following two
combinations: "FCCH+SCH+BCCH+CCCH" and "BCCH+CCCH".
Managed Object

TS
0: TCH/F;
1: TCH/H(0, 1) + FACCH/H(0, 1) + SACCH/TH(0, 1);
3: SDCCH/8+SACCH/C8;
4: FCCH+SCH+BCCH+CCCH;
5: BCCH+SDCCH/4;
6: BCCH+CCCH;
7: BCCH+SDCCH/4+CBCH;
8: SDCCH+CBCH;
12: PBCCH+ PCCCH+PDTCH+PACCH+PTCCH;
13: PCCCH+PDTCH+PACCH+PTCCH;

Value Range and Step

14: PDTCH+PACCH+PTCCH

Unit

None

Default Value

0: TCH/F

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline
ZGB-03-02-005 Static Channel Management
ZGB-03-02-006 Dynamic Channel Management

Related features

ZGO-03-02-008 EGPRS on BCCH-TRX Configurable

Related Parameters

None

Relationship

None

5-19
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->Channel


Info

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.2.3 TSC (TSC)


Full Name

TSC

Abbreviation

TSC

3GPP Name

Training Sequence Code

3GPP Reference

3GPP TS 45.002
This parameter represents Training Serial Code (TSC) of the timeslot.
There are eight types of TSC, with low mutual dependency. It is used
for reference of delay compensation for adaptive balance circuit at the
receiving side. For the timeslot which BCCH occupies, this parameter

Description

must be equal to BCC of a cell.

Managed Object

TS
0..7

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]BCC

Relationship

TSC value on BCCH channel shall be same as BCC value.

5-20
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->Channel


Info

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.2.4 MAIO (MAIO)


Full Name

MAIO

Abbreviation

MAIO

3GPP Name

Mobile Allocation Index Offset

3GPP Reference

3GPP TS 44.018
During the radio communication, the carrier number used on the air
interface is an element of the MA set. Mobile Allocation Index (MAI) (0
MAI n-1) is a variable used for determining a definite element in
the MA set.
According to the frequency hopping algorithm in GSM 05.02
specification, MAI is function of the following aspects: TDMA Frame
Number (FN) or Reduced TDMA Frame Number (RFN), frequency
Hopping Serial Number (HSN), and Mobile Allocation Index Offset
(MAIO). MAIO is an initial offset of MAI and is used for preventing
several channels to contend for the same carrier at the same moment.
Generally, several basic FH units (timeslot or TDMA frame) constitute an
FH group. They have the same MA and HSN and the only difference
among them is MAIO. Thus the same MA and HSN are put in FHS/MA
table. When the FH group corresponding to the timeslot has no

Description

frequency hopping, MAIO of the timeslot is invalid.

Managed Object

TS
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

5-21
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline
ZGO-04-03-001 Synthesized Frequency Hopping

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->Channel

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Info
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.2.5 Dynamic TS
Full Name

Dynamic TS

Abbreviation

None

3GPP Name

None

3GPP Reference

None
"Yes" means that this time slot is dynamic. A dynamic time slot can
transform PDCH channel for PS services. It can also be applied to CS
services.
"No" means that this time slot is fixed.
This parameter appears at two places on OMC. One is used for batch
configurations on all the time slots in a carrier. And the other is used

Description

for configuration on a slot.

Managed Object

TS
0: No

Value Range and Step

1: Yes
5-22

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

None

Default Value

Yes

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The time slot attribute is dynamic by default. The attribute can be


changed to static TCH channel or PDCH channel based on the needs of
CS or PS services, or on the needs of customer.
The attribute can be changed to static TCH channel or PDCH channel
based on the needs of CS or PS services, or on the needs of customer.
Dynamic half rate can be enabled with this parameter being set "Yes".

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->Channel


Info

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.2.6 Ps Service Preference Property


Full Name

Ps Service Preference Property

Abbreviation

None

3GPP Name

None

3GPP Reference

None

5-23
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the preference property among GPRS, EDGE


and EDGE2 services when a user is in PS service.
255: No preference All PS service types can be used.
0: GPRS Preferred When HybridOccuSupp switch is turned off, EDGE
services cannot use this channel. When HybridOccuSupp switch is
turned on, EDGE services can use the channel, but the priority is low.
1: EDGE Preferred When HybridOccuSupp switch is turned off, GPRS
services cannot use this channel. When HybridOccuSupp switch is
turned on, GPRS services can use the channel, but the priority is low.
2: EDGEDedicated GPRS services cannot use the channel.
3: EGPRRS2-A Preferred Common GPRS and EDGE services have low
priorities on this channel.
4: EGPRRS2-A Dedicated Common GPRS and EDGE services cannot
use the channel.
This parameter appears at two places on OMC. One is used for
configurations on all the time slots in a carrier. And the other is used
Description

for configuration on a slot.

Managed Object

TS
255, 0..4
255: No preference
0: GPRS Preferred
1: EDGE Preferred
2: EDGE Dedicated
3: EGPRRS2-A Preferred

Value Range and Step

4: EGPRRS2-A Dedicated

Unit

None

Default Value

No preference

Default Value
Configuration Reason

GPRS amd EDGE services can share one dynamic timeslot.


If an EDGE service needs a high transmission rate, it is recommended

Configuration Rule and

to configure a certain number of static EDGE-dedicated channel. Also

Adjustment Suggestion

EDGE-preferred and GPRS-preferred can be configured to separate


the two types of services.

Change Mode

Offline

Related features

ZGO-03-02-009 Flexible Priority Handling of Packet Data Channel

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

5-24
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->Channel


Info

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.2.7 PDCH Precedence (PDCHPrecedence)


Full Name

PDCH Precedence

Abbreviation

PDCHPrecedence

3GPP Name

None

3GPP Reference

None
If this attribute of a dynamic timeslot is set as TRUE and is occupied by
PS services, the corresponding channel cannot used by CS services.
This configuration can improve the access performance index.
If the attribute of a dynamic timeslot is set as True and PSPrmpCSSupport
switch is turned on, PS services will grab the resources from CS services
when the radio resources are not enough.
This parameter appears at two places on OMC. One is used for batch
configurations on all the time slots in a carrier. And the other is used

Description

for configuration on a slot.

Managed Object

TS
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

Usually this type of dynamic channel does not need to be configured.


If this attribute of a dynamic timeslot is set as TRUE and is occupied by
PS services, the corresponding channel cannot used by CS services.

Configuration Rule and

This configuration can improve the access performance index.

Adjustment Suggestion

To ensure a certain amount of PS services running on the channel when


there are not enough channel resources, the PSPrmpCSSupport switch
can be turned on to make PS services grab resources from CS services.

5-25
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->Channel

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Info
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.2.8 TSC
Full Name

TSC

Abbreviation

TSC

3GPP Name

training sequence Code

3GPP Reference

3GPP TS 45.002 V5.13.0


It is training serial code (TSC). TSC value in BCCH channel shall be same

Description

as BCC value.

Managed Object

TRX

Value Range and Step

0~7

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None
5-26

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->Channel Info

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.2.9 TSC2
Full Name

TSC2

Abbreviation

TSC2

3GPP Name

Training Sequence Code

3GPP Reference

3GPP TS 45.002
This parameter is used for pairing of two non-VAMOS MSs. One MS uses

Description

TSC and the other MS uses TSC2.

Managed Object

TS

Value Range and Step

0..7

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

None
When the VAMOS function is disabled, this parameter is invalid. When
the VAMOS function is enabled, the value configured must be different
from that of TSC.

Change Mode

Offline

Related features

ZGO-04-05-003 VAMOS Pairing and De-Pairing

Related Parameters

[Cell]SupportVAMOS
[TS]TSC

Relationship
Related Interfaces

When SupportVAMOS is enabled, TSC2 is valid. The value of TSC2


must be different from that of TSC.
None

5-27
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->IP


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.1.2.10 PDCH (PDCHPrecedence)


Full Name

PDCH

Abbreviation

PDCHPrecedence

3GPP Name

None

3GPP Reference

None
If this attribute of a dynamic timeslot is set as TRUE and is occupied by
PS services, the corresponding channel cannot used by CS services.
This configuration can improve the access performance index.
If the attribute of a dynamic timeslot is set as True and PSPrmpCSSupport
switch is turned on, PS services will grab the resources from CS services
when the radio resources are not enough.
This parameter appears at two places on OMC. One is used for batch
configurations on all the time slots in a carrier. And the other is used

Description

for configuration on a slot.

Managed Object

TS
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

Usually this type of dynamic channel does not need to be configured.

5-28
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

If this attribute of a dynamic timeslot is set as TRUE and is occupied by


PS services, the corresponding channel cannot used by CS services.
Configuration Rule and

This configuration can improve the access performance index.

Adjustment Suggestion

To ensure a certain amount of PS services running on the channel when


there are not enough channel resources, the PSPrmpCSSupport switch
can be turned on to make PS services grab resources from CS services.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->Channel


Info

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.2.11 PS service preference


Full Name

PS service preference

Abbreviation

None

3GPP Name

None

3GPP Reference

None
This parameter indicates the preference property among GPRS, EDGE
and EDGE2 services when a user is using PS services.
255: No preference All PS service types can be used.
0: GPRS Preferred When HybridOccuSupp switch is turned off, EDGE
services cannot use this channel. When HybridOccuSupp switch is
turned on, EDGE services can use the channel, but the priority is low.
1: EDGE Preferred When HybridOccuSupp switch is turned off, GPRS
services cannot use this channel. When HybridOccuSupp switch is
turned on, GPRS services can use the channel, but the priority is low.

Description

2: EDGEDedicated GPRS services cannot use the channel.

5-29
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3: EGPRRS2-A Preferred Common GPRS and EDGE services have low


priorities on this channel.
4: EGPRRS2-A Dedicated Common GPRS and EDGE services cannot
use the channel.
This parameter appears at two places on OMC. One is used for batch
configurations on all the time slots in a carrier. And the other is used
for configuration on a slot.
Managed Object

TS
255, 0..4
255: No preference
0: GPRS Preferred
1: EDGE Preferred
2: EDGE Dedicated
3: EGPRRS2-A Preferred

Value Range and Step

4: EGPRRS2-A Dedicated

Unit

None

Default Value

No preference

Default Value
Configuration Reason

GPRS and EDGE services can share one dynamic timeslot.

Configuration Rule and

to configure a certain number of static EDGE-dedicated channel. Also

Adjustment Suggestion

EDGE-preferred and GPRS-preferred can be configured to separate

If an EDGE service needs a high transmission rate, it is recommended

the two types of services.


Change Mode

Offline

Related features

ZGO-03-02-009 Flexible Priority Handling of Packet Data Channel

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->Channel


Info

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-30
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.1.2.12 Dynamic TS (Changeable)


Full Name

Dynamic TS

Abbreviation

Changeable

3GPP Name

None

3GPP Reference

None
"Yes" means that this time slot is dynamic. A dynamic time slot can
transform PDCH channel for PS services. It can also be applied to CS
services.
"No" means that this time slot is fixed.
This parameter appears at two places on OMC. One is used for batch
configurations on all the time slots in a carrier. And the other is used

Description

for configuration on a slot.

Managed Object

TS
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The timeslot attribute is dynamic by default. The attribute can be


changed to static TCH channel or static PDCH channel based on the
needs of CS or PS services, or on the needs of customer.

Configuration Rule and

The attribute can be changed to static TCH channel or PDCH channel

Adjustment Suggestion

based on the needs of CS or PS services, or on the needs of customer.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->Channel


Info

Parameter Modifying
Version

None

5-31
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.1.2.13 TS PDCH-Pair Config (ChannelPairChoice)


Full Name

TS PDCH-Pair Config

Abbreviation

ChannelPairChoice

3GPP Name

Internal

3GPP Reference

None
When the carrier is configured as supporting RTTI, this parameter indicates the channel pair choice. That is, which of the four pairs ( PAIR1,

Description

PAIR2, PAIR3, PAIR4) is configured.

Managed Object

TRX
1: PAIR1=TS0 +TS1 configure
2: PAIR2 = TS2 +TS3 configure
3: PAIR3 = TS4 +TS5 configure

Value Range and Step

4: PAIR4 = TS6 +TS7 configure

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional parameter, which is not configured by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]Info_4_3
[TRX]INFO1_4_3

Relationship

This parameter is valid after the BSC switch and cell switch with
RTTIfunction are enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->Channel


Info

5-32
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.3 IP Parameters
5.1.3.1 Port No.
Full Name

Port No.

Abbreviation

None

3GPP Name

None

3GPP Reference

None
This parameter indicates the port number, which shall be allocated for
each carrier, and the number will be determined by the port actually con-

Description

figured.

Managed Object

TRX
1..3072

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The OMC will generate the port numbers sequentially. It is not

Configuration Reason

recommend to modify the numbers.

Configuration Rule and

The OMC will generate the port numbers sequentially. It is not

Adjustment Suggestion

recommend to modify the numbers.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->IP


Parameters
5-33

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.3.2 TRX group No. (TrxGroupNo)


Full Name

TRX group No.

Abbreviation

TrxGroupNo

3GPP Name

None

3GPP Reference

None
This parameter indicates the carrier frequency group ID. For IP site,
the parameter needs to be configured. For 100M platform, the number
of the carrier frequencies in a group should not be more than 16; for
1000M platform, the number of the carrier frequencies in a group should

Description

not be more than 28.

Managed Object

TRX
1..330

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

Configure the carrier frequency group according to the number of carrier

Adjustment Suggestion

frequencies and the number of IPRBDSP. The data needs to be planned.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->IP

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters

5-34
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.3.3 Local switch port (LocalSwitchPort)


Full Name

Local switch port

Abbreviation

LocalSwitchPort

3GPP Name

None

3GPP Reference

None
This parameter specifies the carrier port number for local switching. The
default value of this parameter is 0. When the global switch and the site
group switch are enabled, or the local switching in the site is enabled, the

Description

carrier port No. must be configured.

Managed Object

TRX
0..65535
0: invalid value
Other values: The parameter value is valid in the case of SDR access.

Value Range and Step

In an iBSC, each carrier port No. is unique.

Unit

None

Default Value

Default Value
Configuration Reason

Set this parameter according to the actual configuration of the network.

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

[BSC]LocalSwitchSup

Relationship

This parameter is valid only when the local switching is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-35
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->TRX->IP


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.4 Panel Parameters


5.1.4.1 TRX mode (TRX Mode)
Full Name

TRX mode

Abbreviation

TRX Mode

3GPP Name

None

3GPP Reference

None
This parameter indicates the working mode of carrier, single-carrier or
dual-carrier mode, and decides whether to use four-way diversity on
uplinks and whether to use DPCT or DDT on downlinks. The SDR base
station does not support DDT.
Four-way diversity refers to Rx diversity that combines four ways of
diversity reception to achieve optimum gain and maximize the receiving
performance of base station uplinks. The base station can provide
ultra-broad coverage when four-way diversity reception is used along
with downlink Tx diversity.
DPCT refers to a formal carrier that is formed to get a transmit gain of
2.5dB after two transmitters produce the same bursts at the same time
and the pulses pass through a combiner. By using DPCT, the coverage
of cells can be expanded and downlinks can be intensified in rural areas.
Generally, DPCT can be used together with four-way diversity reception
or MRC to provide ultra-broad coverage.
DDT refers to downlink delay diversity transmission in which the two
transmitters in the dual-density carrier module of the BTS send the same
signals within short delays. The two transmitters are used as one virtual
transmitter to enhance downlink signals and achieve a downlink gain
of 3dB to 6dB. In this way, the coverage is expanded and intensified
by 20% or more.
Four-way diversity, DPCT, and DDT must be supported by suitable

Description

hardware.

Managed Object

Rack

5-36
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Dual carrier
Single carrier with 4-ways diversity reception
Single carrier with 4-ways diversity reception and DPCT
Single carrier with 4-ways diversity reception and DDT
Value Range and Step

Single carrier

Unit

None

Default Value

Dual carrier

Default Value

Generally, the current networks are configured with dual-carrier,

Configuration Reason

depending on carrier characteristics.


By default, dual-carrier mode is used, without DPCT or DDT function.

Configuration Rule and


Adjustment Suggestion

For a broader coverage, single-carrier mode can be used, with four-way


diversity plus DPCT or DDT to increase the coverage and call completion
rate. For downlinks, 2-3dB can be increased to improve voice quality.
DPCT and DDT cannot be used at the same time.

Change Mode

Offline
ZGO-04-01-002 Delay Diversity Transmission & ZGO-04-01-003 Dual
Power Combining Transmission (DPCT) & ZGO-04-01-004 Four Way

Related features

Diversity Receiving(FWDR)

Related Parameters

[Rack]Support antenna hop


[Rack]Delay count
The "Support antenna hop" parameter is valid only when this parameter

Relationship

is set to be "Dual carrier".


The "Delay count" parameter is valid only when this parameter is set to
be "Single carrier with 4-ways diversity reception and DDT".

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site ID->Rack->Panel->Panel Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.4.2 Delay count (Delay count)


Full Name

Delay count

5-37
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

Delay count

3GPP Name

None

3GPP Reference

None
This parameter is used for the DDT function. It defines the number of symbols used for delayed transmission. This parameter is valid only when the
"TRX mode" parameter is "Single carrier with 4-ways diversity reception

Description

and DDT". The SDR base station does not support DDT.

Managed Object

Rack
0..15

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

This parameter is valid only when the "TRX mode" parameter is "Single

Configuration Reason

carrier with 4-ways diversity reception and DDT". By default, it is invalid.

Configuration Rule and

The higher the value is, the bigger the valid Delay Count range will be

Adjustment Suggestion

and the more delayed transmissions there will be.

Change Mode

Offline

Related features

ZGO-04-01-002 Delay Diversity Transmission

Related Parameters

[Rack]TRX Mode

Relationship

This parameter is valid when the "TRX mode" parameter is "Single


carrier with 4-ways diversity reception and DDT".

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site ID->Rack->Panel->Panel Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.1.4.3 IRC (IRC)


Full Name

IRC

Abbreviation

IRC
5-38

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

None

3GPP Reference

None
This parameter decides whether to use the IRC function.
Cleared: IRC unused
Selected: IRC used
Interference Rejection Combining (IRC) is an advanced interference
suppression algorithm and improved diversity reception mode that
suppress intra-frequency interferences based on their relevance to
improve signal reception, reduce bit errors, and upgrade the quality
of uplink services in GSM systems. Compared with Maximum Ratio
Combining (MRC), an uplink Rx algorithm which is widely used in current
networks, IRC can improve uplink signal reception, traffic access, traffic
holding, and traffic handover. In terms of frequency planning, using
IRC can effectively reduce uplink interferences, improve voice quality,
increase uplink data throughput, and decrease call drops in current
networks that are being expanded with more frequency multiplexing.
By default, the V3 software supports IRC, which cannot be enabled or

Description

disabled through the network management system.

Managed Object

Rack

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

The IRC function can significantly improve the uplink quality. It is

Adjustment Suggestion

recommended to enable the function if possible.

Change Mode

Offline

Related features

ZGO-04-01-005 Interference Rejection Combining (IRC)

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site ID->Rack->Panel->Panel Property

Parameter Modifying
Version

None
5-39

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.1.4.4 Support antenna hop (Support antenna hop)


Full Name

Support antenna hop

Abbreviation

Support antenna hop

3GPP Name

None

3GPP Reference

None
This parameter indicates whether antenna hop is supported.
Support antenna hop: Different bursts of the same frequency are sent
by the base station Tx antennas (two or more) alternately to achieve

Description

Tx diversity.

Managed Object

Rack

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


This function can provide higher anti-interference performance for the
downlink signals at the air interface. However, the V3 base station does
not support the function currently.

Change Mode

Offline

Related features

ZGO-04-03-005 Antenna Hopping

Related Parameters

[Rack]TRX Mode

Relationship

This parameter is valid only when the "TRX mode" parameter is 'Dual
carrier'.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site ID->Rack->Panel->Panel Property

Parameter Modifying
Version

None

5-40
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.2 Power Control Parameters


There are four sub-interfaces for basic power control. If the cell supports GPRS, the GPRS
Power Control tab is added

5.2.1 Power Control Parameters


5.2.1.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None

Description

This parameter means the site ID. It cannot be modified.


Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config
Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power Con-

OMC Access Path

trol->Power Control
5-41

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter

Modifying

Version
Parameter

None
Modifying

Detail

None

5.2.1.2 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell
1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

5-42
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config
Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power Con-

OMC Access Path


Parameter

Modifying

Version
Parameter

trol->Power Control

None
Modifying

Detail

None

5.2.1.3 Sub cell ID (SubCellId)


Full Name

Sub cell ID

Abbreviation

SubCellId

3GPP Name

None

3GPP Reference

None

Description

This parameter means the subcell ID. It cannot be modified.

Managed Object

Cell

Value Range and Step

1~2

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO

5-43
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power ConOMC Access Path
Parameter

Modifying

Version
Parameter

trol->Power Control

None
Modifying

Detail

None

5.2.1.4 Uplink rapid power control indication (UIRapidPcInd)


Full Name

Uplink rapid power control indication

Abbreviation

UIRapidPcInd

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter determines the availability of the rapid power control
process. Rapid power control is an optional function of BTS. It reduces
the interference of the radio system and satisfies the dynamic power
control requirement for rapid moving MS.
The amplitude of power control used by rapid power control process
each time is no longer a fixed value, but an integer multiple of cell
parameter power control step (increase and decrease). The RapidPc

Description

parameter determines whether rapid power control process is allowed.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

MS power can be adjusted quickly to reduce interference. Then BTS

Configuration Reason

can get a steady level.


Configuration principle: The configuration can be adjusted based on the
real-time receiving signal level and the value difference between quality

Configuration Rule and

and the expected threshold. This power control mode can meet the

Adjustment Suggestion

needs of dynamic power control for rapid moving MS. However, it will
cause the transmission power for BTS or MS to adjust too quickly, which
will result in unsteady receiving signals.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

5-44
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.1.5 Downlink rapid power control indication (DIRapidPcInd)


Full Name

Downlink rapid power control indication

Abbreviation

DIRapidPcInd

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter determines the availability of the rapid power control
process. Rapid power control is an optional function of BTS. It reduces
the interference of the radio system and satisfies the dynamic power
control requirement for rapid moving MS.
The amplitude of power control used by rapid power control process
each time is no longer a fixed value, but an integer multiple of cell
parameter power control step (increase and decrease). The RapidPc

Description

parameterr determines whether rapid power control process is allowed.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

Enabling downlink rapid power control is likely to cause the deterioration

Configuration Reason

of RQ.

Configuration Rule and


Adjustment Suggestion
Change Mode

This power control mode can meet the needs of dynamic power control
for rapid moving MS. However, it will cause the BTS transmission power
to adjust too quickly, which will result in unsteady receiving signals.
Offline

5-45
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Power Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.1.6 Power control PwrDecrLimit (PwrDecrLimit)


Full Name

Power control PwrDecrLimit

Abbreviation

PwrDecrLimit

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is set to prevent MS from call drop due to fast power
control. It corresponds to different quality level.
For example, PwrDecrLimit [0] determines the maximum power
decrease limit for calls with receiving quality level 0 (Bit Error rate (BER)

Description

<0.2%). This parameter is valid for both uplink and downlink.

Managed Object

Cell
The value range is 0..38.

Value Range and Step

Step: 2

Unit

dB

Default Value

10, 8, 6, 4, 2, 2, 2, 2

Default Value

When the rapid power control is conducted, get the middle value to

Configuration Reason

ensure the speed and to prevent the power from decreasing too quickly.

5-46
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

If the value adjusted higher, the power changing amplitude becomes


Configuration Rule and

bigger and there will risks of call drops; if the value is adjusted lower,

Adjustment Suggestion

the power changing sensitivity will be smaller and the impact of power
control will be reduced.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Power Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.2 Power Survey Parameters


5.2.2.1 Report period of measurement for power control (PwrCtrlReportPrd)
Full Name

Report period of measurement for power control

Abbreviation

PwrCtrlReportPrd

3GPP Name

None

3GPP Reference

3GPP TS 45.008
Power control is performed at BTS side and BSC implements relevant
performance statistics. BTS uses this parameter to decide the periodicity
to send the preprocessed power measurement to BSC as an input for
power control analysis. This parameter is in the unit of SACCH double

Description

frame.

Managed Object

Cell
The value range is 1..254.
The unit is SACCH double frame.

Value Range and Step

Step: 1
5-47

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

Measurement report multi-frame

Default Value

240

Default Value

BTS will report the control performance measurement result each 240

Configuration Reason

51-double frames or 26 double frames.

Configuration Rule and

The default value should be applied. This parameter controls the

Adjustment Suggestion

frequency of power performance measurement report from BTS to iBSC.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Power Survey
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.2.2 Uplink power level (PcUlLevWindow)


Full Name

Uplink power level

Abbreviation

PcUlLevWindow

3GPP Name

None

3GPP Reference

3GPP TS 45.008
The parameter PcUlLevWindow represents the window size (that is, the
number of sample values) used to calculate the average value of uplink

Description

signal strength.

Managed Object

Cell

Value Range and Step

The value range is 1..31. Step: 1

Unit

None

Default Value

5-48
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value
Configuration Reason

Enough number of samples are needed to ensure the correctness of


power control decisions. Meanwhile, a handover should be conducted
as early as possible when the uplink level is weak.
BTS uses the average value of measurement data to avoid adverse
influences caused by abrupt changes in measurement data due to

Configuration Rule and

complex radio transmission.

Adjustment Suggestion

The filtering wave for uplink measurement report becomes more smooth
if the window size is enlarged; the filtering wave for measurement report
becomes more sensitive if the window size becomes smaller.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Power Survey
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.2.3 Uplink power level (PcUlLevWeight)


Full Name

Uplink power level

Abbreviation

PcUlLevWeight

3GPP Name

None

3GPP Reference

3GPP TS 45.008

5-49
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

According to GSM Specifications, discontinuous transmission (DTX)


refers to the process in which the system does not transmit signals in the
voice intermittent period during the subscriber communication process.
With DTX mode, the measurement data reported to BSC fall into two
types. One is the average of the measurement results of all timeslots
in a measurement period in the non-DTX mode, and the other is the
average of the measurement results of some special timeslots in a
measurement period in the DTX mode. The first type of measurement
data is the average of the measurement results of all timeslots, and
it is accurate. The second type of measurement data is the average
of the measurement results of some timeslots, and it is less accurate.
Thus BSC should use different weights for the two types of data when
averaging the measurement results.
This parameter determines the weight for the first type of measurement
data when averaging uplink signal strength for power control. Weight for
Description

the second type of measurement data is set to 1 by default.

Managed Object

Cell
The value range is 1..3.

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

More precise
In the same period, FULL value is calculated from more sampling points
and it is more precise. SUB value is calculated from few sampling points,
so it is less precise. This parameter is not recommended to be modified.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Survey

5-50
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.2.4 Downlink power level (PcDlLevWindow)


Full Name

Downlink power level

Abbreviation

PcDlLevWindow

3GPP Name

None

3GPP Reference

3GPP TS 45.008
PcUlLevWindow calculates the uplink signal strength.

Description

The window size for the average calculation is the number of samples.

Managed Object

Cell
The value range is 1..31.

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Enough number of samples are needed to ensure the correctness of


handover. Meanwhile, a handover should be conducted as early as
possible when the signal is weak.
BTS uses the average value of measurement data to avoid adverse
influences caused by abrupt changes in measurement data due to

Configuration Rule and

complex radio transmission.

Adjustment Suggestion

The filtering wave for uplink measurement report becomes more smooth
if the window size is enlarged; the filtering wave for measurement report
becomes more sensitive if the window size becomes smaller.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-51
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Survey

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.2.5 Downlink power level (PcdlLevWeight)


Full Name

Downlink power level

Abbreviation

PcdlLevWeight

3GPP Name

None

3GPP Reference

3GPP TS 45.008
According to GSM Specifications, discontinuous transmission (DTX)
refers to the process in which the system does not transmit signals in the
voice intermittent period during the subscriber communication process.
With DTX mode, the measurement data reported to BSC fall into two
types. One is the average of the measurement results of all timeslots
in a measurement period in the non-DTX mode, and the other is the
average of the measurement results of some special timeslots in a
measurement period in the DTX mode. When downlink DTX is used,
BTS selects the sebset for average calculation; when downlink DTX is
not used, BTS selects the collective set for average calculation. This
parameter determines the weight for the first type of measurement data
when averaging downlink signal strength for power control. Weight for

Description

the second type of measurement data is set to 1 by default.

Managed Object

Cell
The value range is 1..3.

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

More precise
In the same period, FULL value is calculated from more sampling points
and it is more precise. SUB value is calculated from few sampling points,
so it is less precise. This parameter is not recommended to be modified.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control


5-52

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Power Survey
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.2.6 Uplink quality level (PcUlQualWindow)


Full Name

Uplink quality level

Abbreviation

PcUlQualWindow

3GPP Name

None

3GPP Reference

3GPP TS 45.008
The parameter PcUlLevWindow represents the window size (that is, the
number of sample values) used to calculate the average value of uplink

Description

signal strength.

Managed Object

Cell
The value range is 1..31.

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Enough number of samples are needed to ensure the correctness of


power control decisions. Meanwhile, a handover should be conducted
as early as possible when the uplink level is weak.
BTS uses the average value of measurement data to avoid adverse
influences caused by abrupt changes in measurement data due to

Configuration Rule and

complex radio transmission.

Adjustment Suggestion

The filtering wave for uplink measurement report becomes more smooth
if the window size is enlarged; the filtering wave for measurement report
becomes more sensitive if the window size becomes smaller.
5-53

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Power Survey
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.2.7 Uplink quality Weight (PcUlQualWeight)


Full Name

Uplink quality Weight

Abbreviation

PcUlQualWeight

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter determines the weight for the first type of measurement
data when averaging uplink signal quality for power control. Weight for

Description

the second type of measurement data is set to 1 by default.

Managed Object

Cell
The value range is 1..3.

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion
Change Mode

More precise
In the same period, FULL value is calculated from more sampling points
and it is more precise. SUB value is calculated from few sampling points,
so it is less precise. This parameter is not recommended to be modified.
Offline
5-54

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Power Survey
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.2.8 Downlink quality level (PcDlQualWindow)


Full Name

Downlink quality level

Abbreviation

PcDlQualWindow

3GPP Name

None

3GPP Reference

3GPP TS 45.008
The parameter PcUlLevWindow represents the window size (that is, the
number of sample values) used to calculate the average value of downlink

Description

signal quality.

Managed Object

Cell
The value range is 1..31.

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Enough number of samples are needed to ensure the correctness of


power control decisions. Meanwhile, a handover should be conducted
as early as possible when the signal is weak.

5-55
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

BTS uses the average value of measurement data to avoid adverse


influences caused by abrupt changes in measurement data due to
Configuration Rule and

complex radio transmission.

Adjustment Suggestion

The filtering wave for uplink measurement report becomes more smooth
if the window size is enlarged; the filtering wave for measurement report
becomes more sensitive if the window size becomes smaller.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Survey

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.2.9 Downlink quality Weight (PcDlQualWeight)


Full Name

Downlink quality Weight

Abbreviation

PcDlQualWeight

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter determines the weight for the first type of measurement
data when averaging downlink signal quality for power control. Weight

Description

for the second type of measurement data is set to 1 by default.

Managed Object

Cell
The value range is 1..3.

Value Range and Step

Step: 1

Unit

None

Default Value

5-56
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

More precise
In the same period, FULL value is calculated from more sampling points
and it is more precise. SUB value is calculated from few sampling points,
so it is less precise. This parameter is not recommended to be modified.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Power Survey
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.3 Power Adjustment Threshold Parameters


5.2.3.1 Increase downlink level Value N,P (PcDLInclLevThsN/PcDLInclLevThsP)
Full Name

Increase downlink level Value N,P

Abbreviation

PcDLInclLevThsN/PcDLInclLevThsP

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Downlink receiving strength is one of the
factors that may lead to BTS power increase in the downlink direction. If
P out of N recent downlink signal strength averages are lower than the
related thresholds, the downlink transmission power of the BTS should

Description

be increased, because the downlink signals are too weak.

Managed Object

Cell
5-57

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Value Range and Step

1..31

Unit

None

Default Value

3, 2

Default Value
Configuration Reason

The accuracy and sensitivity of the power control should be guaranteed.


If the N and P values are relatively large, the BTS can average more
numbers of level samples. In this case, the accuracy is higher (the burr

Configuration Rule and

is filtered out) but the sensitivity is decreased.

Adjustment Suggestion

Usually, the N and P values for power increase are configured smaller
than those for power decrease. In the case of weak level, the power
can be increased quickly.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Adjust Threshold

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.3.2 Increase downlink level Threshold (PcDLInclLevThsThs)


Full Name

Increase downlink level Threshold

Abbreviation

PcDLInclLevThsThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008

5-58
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Downlink receiving strength is one of the
factors that may lead to BTS power increase in the downlink direction. If
P out of N recent downlink signal strength averages are lower than the
related thresholds, the downlink transmission power of the BTS should
Description

be increased, because the downlink signals are too weak.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

26, 26, 26, 26

Default Value

Generally, the signals with the strength range of [-84 dBm, -76 dBm] can

Configuration Reason

ensure the normal operation of CS services.


If this threshold is configured too low, the receiving strength of the MS is
weak but the power is not controlled. If the threshold is configured too
high, the downlink interference will increase. For the sites that have

Configuration Rule and

requirements on the downlink coverage level, increase the threshold of

Adjustment Suggestion

downlink power control according to the coverage requirements. For


example, for the sites that have requirements on the downlink -75dBm
coverage, it is recommended that the threshold for downlink power
increase or decrease be changed to 36 or 42 respectively.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Adjust Threshold

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-59
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.3.3 Increase uplink quality Value N,P (PcDLInclQualThsN/PcDLInclQualThsP)


Full Name

Increase uplink quality Value N,P

Abbreviation

PcDLInclQualThsN/PcDLInclQualThsP

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Downlink receiving quality is one of the
factors that may lead to BTS power increase in the downlink direction.
The judge process is as follows: If P out of N recent downlink signal
quality averages are higher than the related thresholds, the downlink
transmission power of the BTS should be increased, because the

Description

downlink signals are too poor.

Managed Object

Cell

Value Range and Step

1..31

Unit

None

Default Value

3, 2

Default Value
Configuration Reason

The accuracy and sensitivity of the power control should be guaranteed.


If the N and P values are relatively large, the BTS can average more
numbers of level samples. In this case, the accuracy is higher (the burr

Configuration Rule and

is filtered out) but the sensitivity is decreased.

Adjustment Suggestion

Usually, the N and P values for power increase are configured smaller
than those for power decrease. In the case of poor signal quality, the
power can be increased quickly.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Adjust Threshold

5-60
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.3.4 Increase uplink quality Threshold (PcDLInclQualThsThs)


Full Name

Increase uplink quality Threshold

Abbreviation

PcDLInclQualThsThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Downlink receiving quality is one of the
factors that may lead to BTS power increase in the downlink direction.
The judge process is as follows: If P out of N recent downlink signal
quality averages are higher than the related thresholds, the downlink
transmission power of the BTS should be increased, because the

Description

downlink signals are too poor.

Managed Object

Cell

Value Range and Step

0..7

Unit

None

Default Value

2, 2, 2, 2

Default Value

Generally, the signals with the quality range of [0, 2] can ensure the

Configuration Reason

voice quality of CS services.


If this threshold is configured too high, call drops occur because of
poor MS receiving quality and the proportion of downlink RQs will be
affected. If this threshold is configured too low, the BTS power will
increase in the case of slight interference and the downlink RQ will be
further deteriorated.
The range of quality threshold can be changed according to the uplink

Configuration Rule and


Adjustment Suggestion

and downlink radio environment. If the radio environment is poor, the


range of quality threshold can be changed to [0, 1]. However, with
the increase of the quality threshold, the transmission power of uplink
and downlink signals will increase accordingly. Meanwhile, the mutual
interference will also increase, especially for the downlink interference.
However, under power control, the proportion of the RQ (range: 0-3;
unit: %) increases. During optimization of parameter settings, the
increase of the RQ (range: 0-3; unit: %), power, and interference should
be balanced.
5-61

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Adjust Threshold

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.3.5 Decrease downlink level Value N,P (PcDLRedLevThsN/PcDLRedLevThsP)


Full Name

Decrease downlink level Value N,P

Abbreviation

PcDLRedLevThsN/PcDLRedLevThsP

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Downlink receiving strength is one of the
factors that may lead to BTS power decrease in the downlink direction.
The judge process is as follows: If P out of N recent downlink signal
strength averages are higher than the related thresholds, the downlink
transmission power of the BTS should be decreased, because the

Description

downlink signals are too strong.

Managed Object

Cell

Value Range and Step

1..31

Unit

None

Default Value

3, 2

Default Value
Configuration Reason

The accuracy and sensitivity of the power control should be guaranteed.

5-62
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and


Adjustment Suggestion

If the N and P values are relatively large, the BTS can average more
numbers of level samples. In this case, the accuracy is higher (the burr
is filtered out) but the sensitivity is decreased.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Adjust Threshold

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.3.6 Decrease downlink level Threshold (PcDLRedLevThsThs)


Full Name

Decrease downlink level Threshold

Abbreviation

PcDLRedLevThsThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Downlink receiving strength is one of the
factors that may lead to BTS power decrease in the downlink direction.
The judge process is as follows: If P out of N recent downlink signal
strength averages are higher than the related thresholds, the downlink
transmission power of the BTS should be decreased, because the

Description

downlink signals are too strong.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

34, 34, 34, 34

5-63
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Generally, the signals with the strength range of [-84 dBm, -76 dBm] can

Configuration Reason

ensure the normal operation of CS services.


If this threshold is configured too low, the receiving strength of the MS is
weak but the power is not controlled. If the threshold is configured too
high, the downlink interference will increase. For the sites that have

Configuration Rule and

requirements on the downlink coverage level, increase the threshold of

Adjustment Suggestion

downlink power control according to the coverage requirements. For


example, for the sites that have requirements on the downlink -75dBm
coverage, it is recommended that the threshold for downlink power
increase or decrease be changed to 36 or 42 respectively.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Power Adjust Threshold
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.3.7 Decrease uplink quality Value N,P (PcDLRedQualThsN/PcDLRedQualThsP)


Full Name

Decrease uplink quality Value N,P

Abbreviation

PcDLRedQualThsN/PcDLRedQualThsP

3GPP Name

None

3GPP Reference

3GPP TS 45.008

5-64
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Downlink receiving quality is one of the
factors that may lead to BTS power decrease in the downlink direction.
The judge process is as follows: If P out of N recent downlink signal
quality averages are lower than the related thresholds, the downlink
transmission power of the BTS should be decreased, because the
Description

downlink signals are too good.

Managed Object

Cell

Value Range and Step

1..31

Unit

None

Default Value

3, 2

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The accuracy and sensitivity of the power control should be guaranteed.


If the N and P values are relatively large, the BTS can average more
numbers of level samples. In this case, the accuracy is higher (the burr
is filtered out) but the sensitivity is decreased.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Adjust Threshold

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.3.8 Decrease uplink quality Threshold (PcDLRedQualThsThs)


Full Name

Decrease uplink quality Threshold

Abbreviation

PcDLRedQualThsThs

5-65
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Downlink receiving quality is one of the
factors that may lead to BTS power decrease in the downlink direction.
The judge process is as follows: If P out of N recent downlink signal
quality averages are lower than the related thresholds, the downlink
transmission power of the BTS should be decreased, because the

Description

downlink signals are too good.

Managed Object

Cell

Value Range and Step

0..7

Unit

None

Default Value

0, 0, 0, 0

Default Value

Generally, the signals with the quality range of [0, 2] can ensure the

Configuration Reason

voice quality of CS services.

Configuration Rule and


Adjustment Suggestion

If this value is adjusted excessively, the power will not increase if the
interference exists and call drops occur due to poor quality. Therefore, it
is recommended that this value be not modified.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Power Adjust Threshold
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-66
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.3.9 Increase uplink level Value N, P (PcULInclLevThsN/PcULInclLevThsP)


Full Name

Increase uplink level Value N, P

Abbreviation

PcULInclLevThsN/PcULInclLevThsP

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Uplink receiving strength is one of the
factors that may lead to MS power decrease in the uplink direction. If P
out of N recent uplink signal strength averages are lower than the related
thresholds, the uplink transmission power of MS should be increased,

Description

because the strength of uplink signals is too weak.

Managed Object

Cell

Value Range and Step

1..31

Unit

None

Default Value

3, 2

Default Value
Configuration Reason

The accuracy and sensitivity of the power control should be guaranteed.


If the N and P values are relatively large, the BTS can average more

Configuration Rule and


Adjustment Suggestion

numbers of level samples. In this case, the accuracy is higher (the burr
is filtered out) but the sensitivity is decreased. Usually, the N and P
values for power increase are configured smaller than those for power
decrease. In the case of weak level, the power can be increased quickly.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Adjust Threshold

Parameter Modifying
Version

None

5-67
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.2.3.10 Increase uplink level Threshold (PcULInclLevThsThs)


Full Name

Increase uplink level Threshold

Abbreviation

PcULInclLevThsThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Uplink receiving strength is one of the
factors that may lead to MS power decrease in the uplink direction. If P
out of N recent uplink signal strength averages are lower than the related
thresholds, the uplink transmission power of MS should be increased,

Description

because the strength of uplink signals is too weak.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

22, 22, 22, 22

Default Value
Configuration Reason

Generally, the signals with the strength range of [-88 dBm, -80 dBm]
can ensure the normal operation of CS services and does not cause
uplink interference.
If this threshold is configured too low, the uplink receiving strength is
weak but the power is not controlled. In this case, it is easy to cause

Configuration Rule and

poor voice quality or call drop. If the threshold is configured too high, the

Adjustment Suggestion

uplink interference will increase. In the case of weak indoor coverage, it


is recommended that this threshold be properly increased to avoid poor
voice quality caused by rapid signal attenuation.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-68
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Adjust Threshold

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.3.11 Increase downlink quality Value N,P (PcULInclQualThsN/PcULInclQualThsP)


Full Name

Increase downlink quality Value N,P

Abbreviation

PcULInclQualThsN/PcULInclQualThsP

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Uplink receiving quality is one of the
factors that may lead to MS power increase in the uplink direction. The
judge process is as follows: If P out of N recent uplink signal quality
averages are higher than the related thresholds, the uplink transmission
power of MS should be increased, because the quality of uplink signals

Description

is too poor.

Managed Object

Cell

Value Range and Step

1..31

Unit

None

Default Value

3, 2

Default Value
Configuration Reason

The accuracy and sensitivity of the power control should be guaranteed.


If the N and P values are relatively large, the BTS can average more
numbers of level samples. In this case, the accuracy is higher (the burr

Configuration Rule and

is filtered out) but the sensitivity is decreased.

Adjustment Suggestion

Usually, the N and P values for power increase are configured smaller
than those for power decrease. In the case of poor signal quality, the
power can be increased quickly.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

5-69
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Adjust Threshold

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.3.12 Increase downlink quality Threshold (PcULInclQualThsThs)


Full Name

Increase downlink quality Threshold

Abbreviation

PcULInclQualThsThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Uplink receiving quality is one of the
factors that may lead to MS power increase in the uplink direction. The
judge process is as follows: If P out of N recent uplink signal quality
averages are higher than the related thresholds, the uplink transmission
power of MS should be increased, because the quality of uplink signals

Description

is too poor.

Managed Object

Cell

Value Range and Step

0..7

Unit

None

Default Value

2, 2, 2, 2

Default Value

Generally, the signals with the quality range of [0, 2] can ensure the

Configuration Reason

voice quality of CS services.

5-70
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

If this threshold is configured too high, call drops occur because of poor
MS receiving quality and the proportion of downlink RQs will be affected.
If this threshold is configured too low, the MS power will increase in the
case of slight interference. As a result, the interference will increase
accordingly.
The range of quality threshold can be changed according to the uplink
Configuration Rule and

and downlink radio environment. If the radio environment is poor, the

Adjustment Suggestion

range of quality threshold can be changed to [0, 1]. However, with


the increase of the quality threshold, the transmission power of uplink
signals will increase accordingly. Meanwhile, the mutual interference
will also increase. However, under power control, the proportion of the
RQ (range: 0-3; unit: %) increases. During optimization of parameter
settings, the increase of the RQ (range: 0-3; unit: %), power, and
interference should be balanced.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Adjust Threshold

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.3.13 Decrease uplink level Value N,P (PcULRedLevThsN/PcULRedLevThsP)


Full Name

Decrease uplink level Value N,P

Abbreviation

PcULRedLevThsN/PcULRedLevThsP

3GPP Name

None

3GPP Reference

3GPP TS 45.008

5-71
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Uplink receiving strength is one of the
factors that may lead to MS power decrease in the uplink direction. The
judge process is as follows: If P out of N recent uplink signal strength
averages are higher than the related thresholds, the uplink transmission
power of MS should be decreased, because the strength of uplink signals
Description

is too strong.

Managed Object

Cell

Value Range and Step

1..31

Unit

None

Default Value

3, 2

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The accuracy and sensitivity of the power control should be guaranteed.


If the N and P values are relatively large, the BTS can average more
numbers of level samples. In this case, the accuracy is higher (the burr
is filtered out) but the sensitivity is decreased.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Adjust Threshold

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.3.14 Decrease uplink level Threshold (PcULRedLevThsThs)


Full Name

Decrease uplink level Threshold

Abbreviation

PcULRedLevThsThs

5-72
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Uplink receiving strength is one of the
factors that may lead to MS power decrease in the uplink direction. The
judge process is as follows: If P out of N recent uplink signal strength
averages are higher than the related thresholds, the uplink transmission
power of MS should be decreased, because the strength of uplink signals

Description

is too strong.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

30, 30, 30, 30

Default Value
Configuration Reason

Generally, the signals with the strength range of [-88 dBm, -80 dBm]
can ensure the normal operation of CS services and does not cause
uplink interference.
If this threshold is configured too low, the MS power will be decreased
when the uplink receiving strength is weak. If this threshold is configured

Configuration Rule and


Adjustment Suggestion

too high, the uplink receiving strength is too strong but the power
lowering will not be decreased. In this case, interference exists. In the
case of weak indoor coverage, it is recommended that this threshold be
properly increased to avoid poor voice quality caused by rapid signal
attenuation.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Adjust Threshold

Parameter Modifying
Version

None

5-73
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.2.3.15 Decrease downlink quality Value N (PcULRedQualThsN/PcULRedQualThsP)


Full Name

Decrease downlink quality Value N

Abbreviation

PcULRedQualThsN/PcULRedQualThsP

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Uplink receiving quality is one of the
factors that may lead to MS power decrease in the uplink direction. The
judge process is as follows: If P out of N recent uplink signal quality
averages are lower than the related thresholds, the uplink transmission
power of MS should be decreased, because the quality of uplink signals

Description

is too good.

Managed Object

Cell

Value Range and Step

1..31

Unit

None

Default Value

3, 2

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The accuracy and sensitivity of the power control should be guaranteed.


If the N and P values are relatively large, the BTS can average more
numbers of level samples. In this case, the accuracy is higher (the burr
is filtered out) but the sensitivity is decreased.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Power Adjust Threshold

5-74
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.3.16 Decrease downlink quality Threshold (PcULRedQualThsThs)


Full Name

Decrease downlink quality Threshold

Abbreviation

PcULRedQualThsThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter is classified into seven types: FR, HR, AFS, AHS,
FR-AMR-WB, OFR-AMR-WB, and OHR-AMR-WB. It can independently
control various voice versions. Uplink receiving quality is one of the
factors that may lead to MS power decrease in the uplink direction. The
judge process is as follows: If P out of N recent uplink signal quality
averages are lower than the related thresholds, the uplink transmission
power of MS should be decreased, because the quality of uplink signals

Description

is too good.

Managed Object

Cell

Value Range and Step

0..7

Unit

None

Default Value

0, 0, 0, 0

Default Value

Generally, the signals with the quality range of [0, 2] can ensure the

Configuration Reason

voice quality of CS services.

Configuration Rule and


Adjustment Suggestion

If this value is adjusted excessively, the power will not increase if the
interference exists and call drops occur due to poor quality. Therefore, it
is recommended that this value be not modified.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-75
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Power Adjust Threshold

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4 Other Parameters


5.2.4.1 FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR uplink power
increase step (PwrIncStep_0~PwrIncStep_6)
FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR uplink
Full Name

power increase step

Abbreviation

PwrIncStep_0~PwrIncStep_6

3GPP Name

None

3GPP Reference

3GPP TS 45.008
It refers to a power increase step, that is, the value of power control variation each time. This parameter is used in uplink directions, and is classified into seven types: FR, HR, AMR FR, AMR HR, AMR WFS, AMR

Description

OWFR, AMR OWHR.

Managed Object

Cell

Value Range and Step

2, 4, and 6.

Unit

db

Default Value

Default Value
Configuration Reason

The principle of quick increase and slow decrease is followed.


If this parameter is configured too small, the uplink power increases

Configuration Rule and

slowly. As a result, the voice quality is deteriorated or even call drops

Adjustment Suggestion

occur. Therefore, it is recommended that the value be not configured


too small.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

5-76
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.2 FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR downlink power


increase step (DLPwrIncStep_0~DLPwrIncStep_6)
FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR downlink
Full Name

power increase step

Abbreviation

DLPwrIncStep_0~DLPwrIncStep_6

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter determines the step of downlink power increase. The
values for increase during downlink power control are FR, HR, AMR FR,

Description

AMR HR, AMR WFS, AMR OWFR, AMR OWHR.

Managed Object

Cell
1/2/4/8/12

Value Range and Step

Step: 0.5

Unit

dB

Default Value

4
To implement smaller sharing granularity after the power sharing function

Default Value

is enabled, it is recommended that this parameter be configured to 1

Configuration Reason

(0.5 dB). If the power sharing function is not enabled, it is recommended


that this parameter be configured to 4 (2 dB).
If this parameter is configured too small, the downlink power increases

Configuration Rule and

slowly. As a result, the voice quality is deteriorated or even call drops

Adjustment Suggestion

occur. Therefore, it is recommended that the value be not configured


too small.

Change Mode

Offline

Related features

None

5-77
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.3 FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR uplink power


descreasing step (PwrRedStep_0~PwrRedStep_6)
FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR uplink
Full Name

power descreasing step

Abbreviation

PwrRedStep_0~PwrRedStep_6

3GPP Name

None

3GPP Reference

3GPP TS 45.008
It refers to a power decrease step, that is, the value of power control
variation each time. This parameter is used in downlink directions, and is
classified into seven types: FR, HR, AMR FR, AMR HR, AMR WFS, AMR

Description

OWFR, AMR OWHR.

Managed Object

Cell

Value Range and Step

2, 4, and 6.

Unit

db

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The principle of quick increase and slow decrease is followed.


If this parameter is configured too large, the uplink power may be
decreased sharply in some special cases. As a result, the KPIs such as
call drop will be affected.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control


5-78

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.4 FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR Downlink power


decreasing step (DLPwrRedStep_0~DLPwrRedStep_6)
FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR downlink
Full Name

power reduction step


FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR Downlink

Abbreviation

power decreasing stepDLPwrRedStep_0~DLPwrRedStep_6

3GPP Name

None

3GPP Reference

3GPP TS 45.008
This parameter determines the step of downlink power decrease. The
values for decrease during downlink power control are FR, HR, AMR FR,

Description

AMR HR, AMR WFS, AMR OWFR, AMR OWHR.

Managed Object

Cell
1/2/4/8/12

Value Range and Step

Step: 0.5

Unit

dB

Default Value

4
To implement smaller sharing granularity after the power sharing function

Default Value

is enabled, it is recommended that this parameter be configured to 1

Configuration Reason

(0.5 dB). If the power sharing function is not enabled, it is recommended


that this parameter be configured to 4 (2 dB).

5-79
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the downlink power may be


decreased sharply in some special cases. As a result, the KPIs such as
call drop will be affected.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.5 Uplink power control allowed (PwrControlUl)


Full Name

Uplink power control allowed

Abbreviation

PwrControlUl

3GPP Name

None

3GPP Reference

3GPP TS 45.008
According to different demands from the network, object for the power
control can be chosen. If the MS transmission power needs to be adjusted

Description

dynamically, enable"uplink power control".

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

Adjust the output power of MS to make BTS obtain the steady receiving
signal strength. Therefore, the interference from the same frequency
can be decreased and the power will be saved.

5-80
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Applicable scenario: decrease uplink interference and MS power


consuming. In environments except for high-speed railway, this function
is recommended to be enabled.
Functions: After the uplink power control is enabled, BTS will obtain the
steady receiving signal strength. Therefore, the uplink interference from
Configuration Rule and

the same frequency can be decreased and the MS power consuming

Adjustment Suggestion

will be reduced.
Risks: If the uplink power control is not conducted in time, or the
parameter is not configured properly, voice quality problem will be
brought up and call drops will happen.
The initial power control rate for SDR base station is slow. It is
recommended to start fast average (fastavg) function.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

[Cell]FastAvg

Relationship

If fastavg function is enabled, the initial power control will speed up.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Others
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.6 Downlink power control allowed (PwrControlDl)


Full Name

Downlink power control allowed

Abbreviation

PwrControlDl

3GPP Name

None

3GPP Reference

3GPP TS 45.008
According to different demands from the network, object for the power
control can be chosen. If the BTS transmission power needs to be ad-

Description

justed dynamically, enable"downlink power control".

5-81
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

BTS transmit with the highest power to ensure proper coverage and

Configuration Reason

downlink receiving level.


Applicable scenario: decrease downlink interference and BTS power
consuming. This function is recommended to be enabled in the
dense-populated area and places with strong inner network signal
interference.
Functions: After the downlink power control is enabled, an MS will

Configuration Rule and


Adjustment Suggestion

obtain the steady receiving signal strength. Therefore, the downlink


interference from the same frequency can be decreased and the BTS
power consuming will be reduced.
Risks: If the downlink power control is not conducted in time, or the
parameter is not configured properly, voice quality problem will be
brought up and call drops will happen.
The initial power control rate for SDR base station is slow. It is
recommended to start fast average (FastAvg) function.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

[Cell]FastAvg
[Cell]PwrDynShare
1. Open the fastavg function to speed up the power control;

Relationship

2.If the BTS type is SDR and the "downlink power control"needs to be
enabled, choose "Yes" to make this parameter configurable.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-82
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.4.7 FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR MS Max power


level of MS (MsTxPwrMax_0~MsTxPwrMax_6)
FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR MS Max
Full Name

power level of MS

Abbreviation

MsTxPwrMax_0~MsTxPwrMax_6

3GPP Name

MS_TXPWR_MAX_CCH

3GPP Reference

3GPP TS 45.008
During communication between the MS and the BTS, the transmission
power of the MS is controlled by the network. The network configures
the power of the MS by using the power command. This command is
transmitted on the SACCH channel, which has two header bytes, namely
power control byte and timing advance byte.
The MS acquires the power control header from the downlink SACCH
and take the specified transmission power as the output power. If the
power level of the MS cannot make it output the power value, it will
output the closest transmission power that can be output. When the
BSC implements power control, this parameter refers to the maximum
transmission power available for the MS in the cell. Meanwhile, this
parameter is used by the BSC to calculate the PBGT value. The max
power level for the MS falls into seven categories: FR, HR, AMR FR,

Description

AMR HR, AMR WFS, AMR OWFR, AMR OWHR.

Managed Object

Cell

Value Range and Step

0..31

Unit

db
0(1800M)

Default Value

5(901M)

Default Value
Configuration Reason

This is to maximize the initial transmission power of the MS.


If the initial power of the MS is configured too low, the uplink receiving
power level is weak. As a result, the TCH and the success ratio of SD

Configuration Rule and


Adjustment Suggestion

designation will be affected. Therefore, it is recommended that the


default value of this parameter be not adjusted.
Only when the radio environment is good, a relatively low value can
ensure the normal operation of MS services and reduce the uplink
interference.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

5-83
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.8 FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR MS MIN power


level of MS (MsTxPwrMin_0~MsTxPwrMin_6)
FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR MS MIN
Full Name

power level of MS

Abbreviation

MsTxPwrMin_0~MsTxPwrMin_6

3GPP Name

None

3GPP Reference

3GPP TS 45.008
During communication between the MS and the BTS, the transmission
power of the MS is controlled by the network. The network configures
the power of the MS by using the power command. This command is
transmitted on the SACCH channel, which has two header bytes, namely
power control byte and timing advance byte.
The MS acquires the power control header from the downlink SACCH
and take the specified transmission power as the output power. If the
power level of the MS cannot make it output the power value, it will
output the closest transmission power that can be output. When the
BSC implements power control, this parameter refers to the minimum
transmission power available for the MS in the cell, that is, the lower
threshold of power control. The minimal power level for the MS falls
into seven categories: FR, HR, AMR FR, AMR HR, AMR WFS, AMR

Description

OWFR, AMR OWHR.

Managed Object

Cell

Value Range and Step

0..31

Unit

db
11(1800M)

Default Value

16(901M)
5-84

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

The uplink level and the MS power consumption are ensured

Configuration Reason

simultaneously.
If this parameter is configured too low, the uplink receiving power is
weak. If this parameter is configured too high, the MS transmission

Configuration Rule and


Adjustment Suggestion

power will be high. As a result, the MS power consumption is affected


and the uplink interference exists.
In the case of poor radio environment, this parameter should be
configured to a higher value to ensure the strength of uplink signal
reception.

Change Mode

Offline

Related features

ZGO-04-02-002 Dynamic MS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.9 FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR MS MIN power


level of BS (BsTxPwrMin_0~BsTxPwrMin_6)
FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR MS MIN
Full Name

power level of BS

Abbreviation

BsTxPwrMin_0~BsTxPwrMin_6

3GPP Name

None

3GPP Reference

3GPP TS 45.008

5-85
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

During communication between the BTS and the MS, the transmission
power of the BTS is controlled by the network. The network configures
the power of the BTS by using the power command. The BTS takes
the transmission power specified in the power control command as the
output power. When the BSC implements power control, this parameter
refers to the minimum transmission power available for the BTS in the
cell. The minimal power level for the BS falls into seven categories: FR,
HR, AMR FR, AMR HR, AMR WFS, AMR OWFR, AMR OWHR.
If the maximum power level of the BTS is Pn, then:
l 0: Pn;
l 1: Pn-2 dB;
......
Description

l 15: Pn-30 dB

Managed Object

Cell

Value Range and Step

0..15

Unit

dB

Default Value

10

Default Value
Configuration Reason

The BTS power is adjusted within a high power range.

Configuration Rule and

This parameter indicates the range of power adjustment for the BTS. A

Adjustment Suggestion

high value does not help reduce the downlink network interference.

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-86
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.4.10 FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR MIN interval of


uplink power control (PcMinInterval_0~PcMinInterval_6, SACCH multiframe)
FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR MIN inFull Name

terval of uplink power control

Abbreviation

PcMinInterval_0~PcMinInterval_6, SACCH multiframe

3GPP Name

None

3GPP Reference

3GPP TS 45.008
For SDR BTSs, this parameter indicates the interval between the initial
state to the steady state for BTS power control. Two conditions must be
met when a BTS changes from the initial state to the steady state: This
parameter specifies the minimum interval of power control. Usually, two
survey reports with the original transmission power will be received after
power control. The signal level information in the reports is not accurate
and thus should be ignored (other information such as adjacent cell
information is still valid), therefore there should be a minimum interval of
power control, and signal level information is ignored in this period.
For V3 BTSs, this parameter indicates the interval between the initial
state to the steady state for BTS power control. Two conditions must
be met when a BTS changes from the initial state to the steady state:
1) If the transmission power has not been lowered for N1 times, the
next measurement report will enter the steady state. 2) If the BTS still
remains in the initial state after N2-1 measurement reports have been
received, the N2 measurement report will enter the steady state.
If the parameter is configured between 4 and 17, the N2 value equals to
the value of this parameter.
If this parameter is configured lower than 4, the corresponding N2 value
is 11 measurement reports.
If this parameter is configured lower than 17, the corresponding N2

Description

value is 17 measurement reports.

Managed Object

Cell

Value Range and Step

1..32

Unit

None

Default Value

2
The SDR BTS will abandon the wrong measurement reports to ensure

Default Value

the correctness of power control.

Configuration Reason

The V3 BTS will ensure both the correctness of power control and the
speed of initial power control.
For SDR BTSs, the incorrect 2 measurement reports will be abandoned

Configuration Rule and

between two times of power control. It is recommended that this

Adjustment Suggestion

parameter be not modified.


For V3 BTSs, it is recommended that this parameter be not modified.
5-87

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGO-04-02-001 Dynamic BTS Power Control

Related Parameters

None

Relationship

None

Related Interfaces

Um Interface

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.11 Cell enable power dynamic sharing or not (PwrDynShare)


Full Name

Cell enable power dynamic sharing or not

Abbreviation

PwrDynShare

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the dynamic power sharing function is

Description

enabled.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for special function. The switch is disabled by default.


The dynamic power sharing function is enabled/disabled through this

Configuration Rule and

switch. The switch can improve the utilization of cell power resources. A

Adjustment Suggestion

carrier wave with low transmission power shares its margin power with
the carriers waves that need high transmission power.

Change Mode

Offline

5-88
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

[Cell]PwrControlDl

Relationship

If the BTS type is SDR and the downlink power control is enabled,
choose "Yes" to make to parameter configurable.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.12 Power reserved for present users (PwrPres)


Full Name

Power reserved for present users

Abbreviation

PwrPres

3GPP Name

None

3GPP Reference

None
This parameter indicates the reserved power volume, which is the gain
level added to currently applied power. The 0, 1, 2, 3, 4 respectively

Description

represent 0 dB, 0.5 dB, 1 dB, 1.5 dB, 2 dB.

Managed Object

Cell

Value Range and Step

0[0], 0.5[1], 1[2], 1.5[3], 2[4]

Unit

None

Default Value

0[0]

Default Value
Configuration Reason

The default power gain is 0.

Configuration Rule and


Adjustment Suggestion

It is recommended to adopt the default value.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

5-89
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Others
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.13 Power for initial access users, level of dB based on TRX power (InitAccessPwr)
Full Name

Power for initial access users, level of dB based on TRX power

Abbreviation

InitAccessPwr

3GPP Name

None

3GPP Reference

None
This parameter indicates the initial downlink power. The highest carrier

Description

wave power attenuates 2 dB per grade.

Managed Object

Cell
0..15

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default initial access power does not attenuate.

Configuration Rule and

Set this parameter as required. The initial power decreases if the

Adjustment Suggestion

parameter increases.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

None

Relationship

None
5-90

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.14 Initial downlink power reduction step according to SDCCH measurement


(InitDLPwrRedStep)
Full Name

Initial downlink power reduction step according to SDCCH measurement

Abbreviation

InitDLPwrRedStep

3GPP Name

None

3GPP Reference

None
This parameter adjusts the initial downlink power attenuation level for the
TCH channel based on the measurement report for the SDCCH channel.

Description

This parameter take effect after the dynamic power sharing is enabled.

Managed Object

Cell

Value Range and Step

0, 1, 2

Unit

2 dB

Default Value

Default Value
Configuration Reason

2 db is a reasonable extent.

Configuration Rule and


Adjustment Suggestion

It is recommended to adopt the default value.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]PwrDynShare

Relationship
Related Interfaces

The parameter takes effect when the dynamic power sharing function
is enabled.
None
5-91

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.15 SDCCH RXLEV for increasing TCH downlink power (InitDLPwrInclLevThs)


Full Name

SDCCH RXLEV for increasing TCH downlink power

Abbreviation

InitDLPwrInclLevThs

3GPP Name

None

3GPP Reference

None
This parameter indicates the lower limit value for SD channel level that is
a reference to TCH initializing downlink power. If the MS receiving level
in SD channel survey report is lower than this value, the MS receiving
signal intensity is weak, thus the initializing transmission power of TCH

Description

channel cannot be reduced.

Managed Object

Cell
0 .. 63
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
2: -109 dBm .. -108 dBm;
...
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

22

Default Value

If the access power is lower than -88dBm, the signal is weak and cannot

Configuration Reason

be reduced any more.

Configuration Rule and


Adjustment Suggestion

The default value should be applied.


Set this parameter for the site according to the particular requirements
for the downlink coverage.

5-92
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related features

None

Related Parameters

[BSC]PwrDynShareSupport_1

Relationship

This parameter takes effect when PwrDynShareSupport_1 is initialized.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Others
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.16 SDCCH RXLEV for reducing TCH downlink power (InitDLPwrlRedLevThs)


Full Name

SDCCH RXLEV for reducing TCH downlink power

Abbreviation

InitDLPwrlRedLevThs

3GPP Name

None

3GPP Reference

None
This parameter indicates the SD channel level threshold that is a reference to TCH initializing downlink power. If the MS receiving level in SD
channel survey report is higher than this value, the MS receiving signal
intensity is strong, thus the initializing transmission power of TCH channel

Description

can be reduced.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

55

Default Value
Configuration Reason

The receiving power of -55dBm can ensure good access performance.

5-93
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

The level will be lowered due to decrease of downlink power, so the level
threshold should not be set too low. The transmission power of MS can
be adjusted through power control after the MS access to TCH.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

[Cell]PwrDynShare

Relationship

The parameter takes effect when the dynamic power sharing function
is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Others
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.17 SDCCH RXQUAL for increasing TCH downlink power (InitDLPwrInclQualThs)


Full Name

SDCCH RXQUAL for increasing TCH downlink power

Abbreviation

InitDLPwrInclQualThs

3GPP Name

None

3GPP Reference

None
This parameter indicates the upper limit quality value for SD channel
that is a reference to TCH initializing downlink power. If the MS quality
in SD channel survey report is higher than this value, the MS receiving
quality is poor, thus the initializing transmission power of TCH channel

Description

cannot be reduced.

Managed Object

Cell
0..7

Value Range and Step

Step: 1

Unit

None

Default Value

5-94
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

If the quality level is higher than 2, the power cannot be reduced any

Configuration Reason

more.

Configuration Rule and


Adjustment Suggestion

The default value should be applied.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]PwrDynShareSupport_1

Relationship

This parameter takes effect when PwrDynShareSupport_1 is initialized.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.18 SDCCH RXQUAL for reducing TCH downlink power (InitDLPwrlRedQualThs)


Full Name

SDCCH RXQUAL for reducing TCH downlink power

Abbreviation

InitDLPwrlRedQualThs

3GPP Name

None

3GPP Reference

None
This parameter indicates the SD channel quality threshold that is a reference to TCH initializing downlink power. If the quality level in SD channel
survey report is lower than this value, the MS receiving quality is good
(with low Bit Error Rate), thus the initializing transmission power of TCH

Description

channel can be reduced.

Managed Object

Cell
0..7

Value Range and Step

Step: 1

Unit

None

Default Value

5-95
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

The TCH initializing downlink power can be reduced under the best

Configuration Reason

access quality.
The quality level will be lowered due to decrease of downlink power, so

Configuration Rule and

the quality level threshold should not be set too low. The transmission

Adjustment Suggestion

power of MS can be adjusted through power control after the MS access


to TCH.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

[Cell]PwrDynShare

Relationship

The parameter takes effect when the dynamic power sharing function
is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.19 Power Adjusting Threshold (PwrAdjustThreshold)


Full Name

Power Adjusting Threshold

Abbreviation

PwrAdjustThreshold

3GPP Name

None

3GPP Reference

None
This parameter indicates the congestion control threshold. When BSC
detects that a current service on RRU occupies a certain percentage of
the RRU total power, the congestion control is enabled (handout CS ser-

Description

vices).

Managed Object

Cell
50..100

Value Range and Step

Step: 1

5-96
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

Default Value

100

Default Value
Configuration Reason

100% is the default value.

Configuration Rule and


Adjustment Suggestion

It is recommended to adopt the default value.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

[Cell]PwrAdmitThrldPunish
[Cell]PwrAdmitThreshold

Relationship

Punishment extent against the power access control threshold<Power


access control threshold<Power congestion control threshold

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Others
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.20 Power admitting threshold (PwrAdmitThreshold)


Full Name

Power admitting threshold

Abbreviation

PwrAdmitThreshold

3GPP Name

None

3GPP Reference

None
This parameter indicates the congestion control threshold. When BSC
receives a new service application, the service cannot be accepted if the
power needed by the current service and the new service reaches a
certain percentage of the total RRU power. The acceptance judgment

Description

will be conducted in other time slots.

Managed Object

Cell

5-97
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

10..100
Value Range and Step

Step: 1

Unit

Default Value

90

Default Value

When the power percentage is 90%, RRU power is reaches the limit and

Configuration Reason

the power distribution cannot be conducted.

Configuration Rule and


Adjustment Suggestion

It is recommended to adopt the default value.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

[Cell]PwrAdjustThreshold
[Cell]PwrAdmitThrldPunish

Relationship

Punishment extent against the power access control threshold<Power


access control threshold<Power congestion control threshold

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.21 Power admitting threshold punishment (PwrAdmitThrldPunish)


Full Name

Power admitting threshold punishment

Abbreviation

PwrAdmitThrldPunish

3GPP Name

None

3GPP Reference

None

5-98
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter indicates the punishment extent against the power


access control threshold. When a service is kicked out due to RRU
congestion in a time slot, a new service will be introduced immediately,
which cause the RRU to switch between congestion and smooth state.
At this time, the access threshold has a punishment decrease for a
Description

period of time and the decrease extent equals with the parameter value.

Managed Object

Cell
0..50

Value Range and Step

Step: 1

Unit

Default Value

10

Default Value

Generally, 10% punishment is enough to avoid the ping-pong effect

Configuration Reason

caused by power congestion.

Configuration Rule and


Adjustment Suggestion

It is recommended to adopt the default value.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

[Cell]PwrAdjustThreshold
[Cell]PwrAdmitThreshold

Relationship

Punishment extent against the power access control threshold<Power


access control threshold<Power congestion control threshold

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.22 Power admitting threshold punishment time (PwrAdmitPunishTime)


Full Name

Power admitting threshold punishment time

Abbreviation

PwrAdmitPunishTime

5-99
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

None

3GPP Reference

None
This parameter indicates the punishment period of time against the power
access control threshold. When a service is kicked out due to RRU congestion in a time slot, a new service will be introduced immediately, which
cause the RRU to switch between congestion and smooth state. At this
time, the access threshold has a punishment decrease and the period of

Description

time equals with the parameter value.

Managed Object

Cell
0..255

Value Range and Step

Step: 1

Unit

Default Value

30

Default Value

Generally, 30 s punishment is enough to avoid the ping-pong effect

Configuration Reason

caused by power congestion.

Configuration Rule and


Adjustment Suggestion

It is recommended to adopt the default value.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.23 Power adjustment methods priority 1 (PwrAdjPriority_0)


Full Name

Power adjustment methods priority 1

5-100
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Abbreviation

PwrAdjPriority_0

3GPP Name

None

3GPP Reference

None
When the congestion control with the power sharing happens, this parameter is applied in the congestion control algorithm with priority 1 (highest

Description

priority).

Managed Object

Cell
0: invalid algorithm. No congestion control

Value Range and Step

1: Switch out CS services

Unit

None

Default Value

1: Switch out CS services

Default Value

Without the congestion control the PA module will be burned damage

Configuration Reason

under high power. Proper CS services will be chosen for handover.

Configuration Rule and


Adjustment Suggestion

It is recommended to adopt the default value.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

[Cell]PwrDynShare

Relationship

The parameter takes effect when the dynamic power sharing function
is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-101
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.4.24 FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR MIN interval of


downlink power control (DLPcMinInterval_0~DLPcMinInterval_6)
FR/HR/AMR FR/AMR HR/AMR WFS/AMR OWFR/AMR OWHR MIN inFull Name

terval of downlink power control

Abbreviation

DLPcMinInterval_0~DLPcMinInterval_6

3GPP Name

None

3GPP Reference

3GPP TS 45.008
For SDR BTSs, this parameter indicates the interval between the initial
state to the steady state for BTS power control. Two conditions must be
met when a BTS changes from the initial state to the steady state: This
parameter specifies the minimum interval of power control. Usually, two
survey reports with the original transmission power will be received after
power control. The signal level information in the reports is not accurate
and thus should be ignored (other information such as adjacent cell
information is still valid), therefore there should be a minimum interval of
power control, and signal level information is ignored in this period.
For V3 BTSs, this parameter indicates the interval between the initial
state to the steady state for BTS power control. Two conditions must
be met when a BTS changes from the initial state to the steady state:
1) If the transmission power has not been lowered for N1 times, the
next measurement report will enter the steady state. 2) If the BTS still
remains in the initial state after N2-1 measurement reports have been
received, the N2 measurement report will enter the steady state.
If the parameter is configured between 4 and 17, the N2 value equals to
the value of this parameter.
If this parameter is configured lower than 4, the corresponding N2 value
is 11 measurement reports.
If this parameter is configured lower than 17, the corresponding N2

Description

value is 17 measurement reports.

Managed Object

Cell
1..32

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Incorrect measurement reports will be abandoned to ensure correct

Configuration Reason

power control.

Configuration Rule and

Two incorrect measurement reports are abandoned during two times of

Adjustment Suggestion

uplink power control.

Change Mode

Offline

Related features

None

5-102
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.25 BCCH power control downlink (BCCHPwrControlDL)


Full Name

BCCH power control downlink

Abbreviation

BCCHPwrControlDL

3GPP Name

None

3GPP Reference

None
This parameter determines whether to implement power control for the
dedicated channel on the BCCH carrier according to various network re-

Description

quirements.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

Downlink power control is not implemented for the BCCH carrier, so as to

Configuration Reason

ensure that the MS can correctly measure the downlink level of this cell.
Configuration principle: Customers determine whether to enable this
function.

Configuration Rule and


Adjustment Suggestion

Parameter function: This function can be enabled to reduce BTS power


consumption.
Risk after this function is enabled: The downlink level of this cell
measured by using the MS is relatively small, which affects MS
reselection and handover judgment on the network side.

5-103
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.26 BCCH Maximum Power Decrease (BCCHMaxPwrDec)


Full Name

BCCH Maximum Power Decrease

Abbreviation

BCCHMaxPwrDec

3GPP Name

None

3GPP Reference

None
When the BCCH carrier participates in the downlink power control, this
parameter determines the maximum deteriorated value of the dedicated

Description

channel on the BCCH carrier.

Managed Object

Cell
1..60

Value Range and Step

Step: 0.5

Unit

dB

Default Value

Default Value

The value of this parameter defines the range of downlink BCCH power

Configuration Reason

control. As a caution, this parameter is configured to 3 dB.


This parameter is valid only when the downlink power control of BCCH

Configuration Rule and


Adjustment Suggestion

carrier is enabled.
If this parameter is configured too large, the level value of this cell
measured by using the MSs in this cell and the adjacent cell will be
too small.
5-104

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related features

None

Related Parameters

BCCHPwrControlDL

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.27 BCCH idle burst power (BCCHIdleBurstPwr)


Full Name

BCCH idle burst power

Abbreviation

BCCHIdleBurstPwr

3GPP Name

None

3GPP Reference

None

Description

timeslots on the BCCH carrier according to various network requirements.

Managed Object

Cell

This parameter determines whether to decrease the output power of idle

0..61
Value Range and Step

Step: 0.5

Unit

dB

Default Value

Default Value

Do not decrease the output power of idle timeslots on the BCCH carrier,

Configuration Reason

so as to ensure correct measurement on the level of this cell.

5-105
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration principle: Customers determine whether to decrease the


output power of idle timeslots on the BCCH carrier.
Configuration Rule and
Adjustment Suggestion

Decreasing the output power of idle timeslots on the BCCH carrier


can reduce BTS power consumption. If this parameter is configured
too large, the downlink level of this cell measured by using the MS is
relatively small, which affects MS reselection and handover judgment
on the network side.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.28 Uplink exponential filter (ULExpFilter)


Full Name

Uplink exponential filter

Abbreviation

ULExpFilter

3GPP Name

None

3GPP Reference

None
This parameter determines whether to process the uplink level and quality through exponential filtering during uplink power control and use the

Description

processed data for uplink power control judgment.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

5-106
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

Exponential filtering has good effect on eliminating burr. The


disadvantage is that is cannot adapt to sharp fluctuation of radio
environments. By default, this function is disabled.
After the exponential filtering function is enabled, the impact of the latest
measurement samples will be weakened, which helps prevent power
control jitter. However, the sensitivity of power control is also decreased.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.29 Downlink exponential filter (DLExpFilter)


Full Name

Downlink exponential filter

Abbreviation

DLExpFilter

3GPP Name

None

3GPP Reference

None
This parameter determines whether to process the downlink level and
quality through exponential filtering during downlink power control and

Description

use the processed data for downlink power control judgment.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

5-107
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

Exponential filtering has good effect on eliminating burr. The


disadvantage is that is cannot adapt to sharp fluctuation of radio
environments. By default, this function is disabled.
After the exponential filtering function is enabled, the impact of the latest
measurement samples will be weakened, which helps prevent power
control jitter. However, the sensitivity of power control is also decreased.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.30 Uplink level optimize (ULLevOptim)


Full Name

Uplink level optimize

Abbreviation

ULLevOptim

3GPP Name

None

3GPP Reference

None
This parameter determines whether to use the optimized uplink level as
the expected level for uplink power control. The optimized uplink level is
a value between the threshold of uplink power increase and the threshold

Description

of uplink power decrease.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes
5-108

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

After the optimized uplink level is used as the expected uplink strength
Default Value

value, the system can prevent extra power control caused by a close

Configuration Reason

value between the target level and the threshold of power increase or
the threshold of power decrease.

Configuration Rule and

If this function is enabled, the system can prevent ping-pong power

Adjustment Suggestion

control caused by level.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->Others

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.4.31 Downlink level optimize (DLLevOptim)


Full Name

Downlink level optimize

Abbreviation

DLLevOptim

3GPP Name

None

3GPP Reference

None
This parameter determines whether to use the optimized downlink level
as the expected level for downlink power control. The optimized downlink
level is a value between the threshold of downlink power increase and the

Description

threshold of downlink power decrease.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

5-109
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Yes
After the optimized downlink level is used as the expected uplink

Default Value

strength value, the system can prevent extra power control caused by a

Configuration Reason

close value between the target level and the threshold of power increase
or the threshold of power decrease.

Configuration Rule and

If this function is enabled, the system can prevent ping-pong power

Adjustment Suggestion

control caused by level.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Others
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.5 New Power Control Attribute


5.2.5.1 INIT decline Limit (INITDeLimit)
Full Name

INIT decline Limit

Abbreviation

INITDeLimit

3GPP Name

None

3GPP Reference

None

Description

INIT decline Limit

Managed Object

Cell

Value Range and Step

0, 2, 4, 6, 8, 10, 12, 14, 16(0-8 on omcr)

Unit

2db

5-110
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.2 Number of INIT Measure report (INITMRNum)


Full Name

Number of INIT Measure report

Abbreviation

INITMRNum

3GPP Name

None

3GPP Reference

None

Description

Number of INIT Measure report

Managed Object

Cell

Value Range and Step

1..15

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

5-111
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.3 Uplink Rescue Status, Value N (ULRescueN)


Full Name

Uplink Rescue Status, Value N

Abbreviation

ULRescueN

3GPP Name

None

3GPP Reference

None

Description

Uplink Rescue Status, Value N

Managed Object

Cell

Value Range and Step

1..15

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

ULRescueN >= ULRescueP

Change Mode

Offline

Related features

None

5-112
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.4 Uplink Rescue Status, Value P (ULRescueP)


Full Name

Uplink Rescue Status, Value P

Abbreviation

ULRescueP

3GPP Name

None

3GPP Reference

None

Description

Uplink Rescue Status, Value P

Managed Object

Cell

Value Range and Step

1..15

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

ULRescueN >= ULRescueP

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

0
5-113

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.5 Uplink Rescue level threshold (ULRescueLevThs)


Full Name

Uplink Rescue level threshold

Abbreviation

ULRescueLevThs

3GPP Name

None

3GPP Reference

None

Description

Uplink Rescue level threshold

Managed Object

Cell

Value Range and Step

0..63

Unit

N/A

Default Value

20

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

ULRescueLevThs < PcULInclLevThsThs

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-114
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.6 Uplink Rescue quality threshold (ULRescueQualThs)


Full Name

Uplink Rescue quality threshold

Abbreviation

ULRescueQualThs

3GPP Name

None

3GPP Reference

None

Description

Uplink Rescue quality threshold

Managed Object

Cell

Value Range and Step

0..7

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

ULRescueQualThs < PcULInclQualThsThs

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b
5-115

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

5.2.5.7 Downlink Rescue Status, Value N (DLRescueN)


Full Name

Downlink Rescue Status, Value N

Abbreviation

DLRescueN

3GPP Name

None

3GPP Reference

None

Description

Downlink Rescue Status, Value N

Managed Object

Cell

Value Range and Step

1..15

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

DLRescueN >= DLRescueP

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5-116
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.5.8 Downlink Rescue Status, Value P (DLRescueP)


Full Name

Downlink Rescue Status, Value P

Abbreviation

DLRescueP

3GPP Name

None

3GPP Reference

None

Description

Downlink Rescue Status, Value P

Managed Object

Cell

Value Range and Step

1..15

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

DLRescueN >= DLRescueP

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.9 Downlink Rescue level threshold (DLRescueLevThs)


Full Name

Downlink Rescue level threshold

Abbreviation

DLRescueLevThs

3GPP Name

None
5-117

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

None

Description

Downlink Rescue level threshold

Managed Object

Cell

Value Range and Step

0..63

Unit

N/A

Default Value

25

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

DLRescueLevThs < PcDLInclLevThsThs

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.10 Downlink Rescue quality threshold (DLRescueQualThs)


Full Name

Downlink Rescue quality threshold

Abbreviation

DLRescueQualThs

3GPP Name

None

3GPP Reference

None

Description

Downlink Rescue quality threshold

Managed Object

Cell

Value Range and Step

0..7
5-118

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

DLRescueQualThs < PcDLInclQualThsThs

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.11 Uplink exponent filter power control indication (ULExpFiltPCInd)


Full Name

Uplink exponent filter power control indication

Abbreviation

ULExpFiltPCInd

3GPP Name

None

3GPP Reference

None

Description

Uplink exponent filter power control indication

Managed Object

Cell

Value Range and Step

0, 1

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value
5-119

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.12 Downlink exponent filter power control indication (DLExpFiltPCInd)


Full Name

Downlink exponent filter power control indication

Abbreviation

DLExpFiltPCInd

3GPP Name

None

3GPP Reference

None

Description

Downlink exponent filter power control indication

Managed Object

Cell

Value Range and Step

0, 1

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

5-120
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.13 Uplink filtration exponent para K (ULFiltExpParaK)


Full Name

Uplink filtration exponent para K

Abbreviation

ULFiltExpParaK

3GPP Name

None

3GPP Reference

None

Description

Uplink filtration exponent para K

Managed Object

Cell

Value Range and Step

0..15

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

0
5-121

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.14 Filter window len of Uplink level (ULLevFiltWinLen)


Full Name

Filter window len of Uplink level

Abbreviation

ULLevFiltWinLen

3GPP Name

None

3GPP Reference

None

Description

filter window len of Uplink level

Managed Object

Cell

Value Range and Step

1..15

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-122
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.15 Filter window len of Uplink quality (ULQualFiltWinLen)


Full Name

Filter window len of Uplink quality

Abbreviation

ULQualFiltWinLen

3GPP Name

None

3GPP Reference

None

Description

filter window len of Uplink quality

Managed Object

Cell

Value Range and Step

1..15

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b
5-123

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

5.2.5.16 Step of Uplink power decline by quality (ULDebyQuaStep)


Full Name

Step of Uplink power decline by quality

Abbreviation

ULDebyQuaStep

3GPP Name

None

3GPP Reference

None

Description

Step of Uplink power decline by quality

Managed Object

Cell

Value Range and Step

0, 2, 4, 6(0-3 on OMCR)

Unit

2db

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5-124
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.5.17 Step of Uplink power increase by quality (ULInbyQuaStep)


Full Name

Step of Uplink power increase by quality

Abbreviation

ULInbyQuaStep

3GPP Name

None

3GPP Reference

None

Description

Step of Uplink power increase by quality

Managed Object

Cell

Value Range and Step

0, 2, 4, 6(0-3 on OMCR)

Unit

2db

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.18 MAX Step of Uplink power decline by level when quality 0


(ULDebyLevStep_Qua0)
Full Name

MAX Step of Uplink power decline by level when quality 0

Abbreviation

ULDebyLevStep_Qua0

5-125
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

None

3GPP Reference

None

Description

MAX Step of Uplink power decline by level when quality 0

Managed Object

Cell

Value Range and Step

0, 2, 4, 6(0-3 on OMCR)

Unit

2db

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

2
5.2.5.19 MAX Step of Uplink power decline by level when quality 1
(ULDebyLevStep_Qua1)
Full Name

MAX Step of Uplink power decline by level when quality 12

Abbreviation

ULDebyLevStep_Qua1

3GPP Name

None

3GPP Reference

None

Description

MAX Step of Uplink power decline by level when quality 12

5-126
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Cell

Value Range and Step

0, 2, 4, 6(0-3 on OMCR)

Unit

2db

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.20 MAX Step of Uplink power decline by level when other qualitys
(ULDebyLevStep_Qua2)
Full Name

MAX Step of Uplink power decline by level when other qualitys

Abbreviation

ULDebyLevStep_Qua2

3GPP Name

None

3GPP Reference

None

Description

MAX Step of Uplink power decline by level when other qualitys

Managed Object

Cell

Value Range and Step

0, 2, 4, 6(0-3 on OMCR)

Unit

2db

5-127
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.21 Weight sequence of Uplink window Filter (ULWinFiltWeightSequ)


Full Name

Weight sequence of Uplink window Filter

Abbreviation

ULWinFiltWeightSequ

3GPP Name

None

3GPP Reference

None

Description

weight sequence of Uplink window Filter

Managed Object

Cell
1..7
1: all the value is 1
2: the value is 1, 3, 5, 7, ...
3: the value is 2, 4, 6, 8, ...
4: the value is 1, 2, 3, 4, ...
5: the value is 2, 5, 8, 11...
6: the value is 3, 6, 9, 12...

Value Range and Step

7: the value is 1, 4, 7, 10...


5-128

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.22 Downlink filtration exponent para K (DLFiltExpParaK)


Full Name

Downlink filtration exponent para K

Abbreviation

DLFiltExpParaK

3GPP Name

None

3GPP Reference

None

Description

Downlink filtration exponent para K

Managed Object

Cell

Value Range and Step

0..15

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value
5-129

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.23 Filter window len of Downlink level (DLLevFiltWinLen)


Full Name

Filter window len of Downlink level

Abbreviation

DLLevFiltWinLen

3GPP Name

None

3GPP Reference

None

Description

filter window len of Downlink level

Managed Object

Cell

Value Range and Step

1..15

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

5-130
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.24 Filter window len of Downlink quality (DLQualFiltWinLen)


Full Name

Filter window len of Downlink quality

Abbreviation

DLQualFiltWinLen

3GPP Name

None

3GPP Reference

None

Description

filter window len of Downlink quality

Managed Object

Cell

Value Range and Step

1..15

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

0
5-131

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.25 Step of Downlink power decline by quality (DLDebyQuaStep)


Full Name

Step of Downlink power decline by quality

Abbreviation

DLDebyQuaStep

3GPP Name

None

3GPP Reference

None

Description

Step of Downlink power decline by quality

Managed Object

Cell

Value Range and Step

0, 2, 4, 6(0-3 on OMCR)

Unit

2db

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-132
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.26 Step of Downlink power increase by quality (DLInbyQuaStep)


Full Name

Step of Downlink power increase by quality

Abbreviation

DLInbyQuaStep

3GPP Name

None

3GPP Reference

None

Description

Step of Downlink power increase by quality

Managed Object

Cell

Value Range and Step

0, 2, 4, 6(0-3 on OMCR)

Unit

2db

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b
5-133

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

5.2.5.27 MAX Step of Downlink power decline by level when quality 0


(DLDebyLevStep_Qua0)
Full Name

MAX Step of Downlink power decline by level when quality 0

Abbreviation

DLDebyLevStep_Qua0

3GPP Name

None

3GPP Reference

None

Description

MAX Step of Downlink power decline by level when quality 0

Managed Object

Cell

Value Range and Step

0, 2, 4, 6(0-3 on OMCR)

Unit

2db

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5-134
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

2
5.2.5.28 MAX Step of Downlink power decline by level when quality 1
(DLDebyLevStep_Qua1)
Full Name

MAX Step of Downlink power decline by level when quality 12

Abbreviation

DLDebyLevStep_Qua1

3GPP Name

None

3GPP Reference

None

Description

MAX Step of Downlink power decline by level when quality 12

Managed Object

Cell

Value Range and Step

0, 2, 4, 6(0-3 on OMCR)

Unit

2db

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.29 MAX Step of Downlink power decline by level when other qualitys
(DLDebyLevStep_Qua2)
Full Name

MAX Step of Downlink power decline by level when other qualitys

5-135
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

DLDebyLevStep_Qua2

3GPP Name

None

3GPP Reference

None

Description

MAX Step of Downlink power decline by level when other qualitys

Managed Object

Cell

Value Range and Step

0, 2, 4, 6(0-3 on OMCR)

Unit

2db

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.5.30 Weight sequence of Downlink window Filter (DLWinFiltWeightSequ)


Full Name

Weight sequence of Downlink window Filter

Abbreviation

DLWinFiltWeightSequ

3GPP Name

None

3GPP Reference

None

Description

weight sequence of Downlink window Filter


5-136

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Cell
1..7
1: all the value is 1
2: the value is 1, 3, 5, 7, ...
3: the value is 2, 4, 6, 8, ...
4: the value is 1, 2, 3, 4, ...
5: the value is 2, 5, 8, 11...
6: the value is 3, 6, 9, 12...

Value Range and Step

7: the value is 1, 4, 7, 10...

Unit

N/A

Default Value

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Site Config->Site->Cell->Power Control->new


power control attribute

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.2.6 GPRS Power Control Parameters


5.2.6.1 Expected signal intensity of MS (SS_BTS)
Full Name

Expected signal intensity of MS

Abbreviation

SS_BTS
5-137

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

SSb

3GPP Reference

3GPP TS 45.008
This parameter is used for the uplink open-loop power control of GPRS.
SSb = P - L = T0 - CH - PBTS - 48
Where,
PBTS = BTS max output power
P = MS output power
L = Path loss
TCH is a special power control parameter of the MS and channel and
is sent to the MS in an RLC control message.
T0 = 39 dBm for GSM 400, GSM 700, GSM 850 and GSM900

Description

= 36 dBm for DCS1 800 and PCS 1900

Managed Object

Cell
0..63
The specific meanings are:
0: -110 dBm;
1: -109 dBm
......
63: -47 dBm;

Value Range and Step

Step: 1

Unit

None

Default Value

40

Default Value

If the signal strength received by the MS is close to -70dBm, it ensures

Configuration Reason

PS services are performed in a normal case.

Configuration Rule and

If the transmitting power of the MS should be reduced, and interference

Adjustment Suggestion

which is caused by PS services should be alleviated, reduce the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

5-138
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.6.2 Uplink power control strategy (UlPwCtrl)


Full Name

Uplink power control strategy

Abbreviation

UlPwCtrl

3GPP Name

Internal

3GPP Reference

None
This parameter determines the uplink power control policy of GPRS., including the following four modes: No control, Open-loop control, Close-

Description

loop control, Control based on quality.

Managed Object

Cell
0: No control
1: Open-loop control
2: Close-loop control

Value Range and Step

3: Control based on quality

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional parameter, which is not configured by default.


Currently, only the open-loop control is supported. This parameter

Configuration Rule and

value can be set to 1 when the uplink open-loop power control should

Adjustment Suggestion

be enabled on site.If this function is enabled, uplink intra-network


interference can be reduced.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

5-139
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.6.3 Downlink power control strategy (DlPwCtrl)


Full Name

Downlink power control strategy

Abbreviation

DlPwCtrl

3GPP Name

Internal

3GPP Reference

None
This parameter determines the downlink power control strategy of GPRS ,
including the following four modes: No control, Open-loop control, Close-

Description

loop control, Control based on quality.

Managed Object

Cell
0: No control
1: Open-loop control
2: Close-loop control

Value Range and Step

3: Control based on quality

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional parameter, which is not configured by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

5-140
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.6.4 Downlink Power Control Mode (PwCtrlMode)


Full Name

Downlink Power Control Mode

Abbreviation

PwCtrlMode

3GPP Name

BTS_PWR_CTRL_MODE

3GPP Reference

3GPP TS 45.008
This parameter indicates the BTS downlink power control modes, A and
B.In power control mode A, the power of each radio block on the channel
is calculated in accordance with that of the MS to which the radio block
belongs. In power control mode B. the radio blocks belonging to different

Description

MSs on the same channel use the same transmitting power.

Managed Object

Cell
0: Mode A

Value Range and Step

1: Mode B

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional parameter, which is not configured by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

5-141
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.6.5 Power Control Level (PwCtrlLev)


Full Name

Power Control Level

Abbreviation

PwCtrlLev

3GPP Name

Internal

3GPP Reference

None
This parameter determines the power control precision of GPRS, describing the nominal output power and power control precision (dB) sent by the
MS under each power control level.Currently, this parameter is not used

Description

and does not need to be adjusted.

Managed Object

Cell
0..31

Value Range and Step

Step: 1

Unit

db

Default Value

Default Value

Currently, this parameter is not used in this version and does not need

Configuration Reason

to be adjusted.

Configuration Rule and


Adjustment Suggestion

Currently, this parameter is not used and does not need to be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

5-142
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.6.6 Power descending of PDCH to BCCH in mode A (P0)


Full Name

Power descending of PDCH to BCCH in mode A

Abbreviation

P0

3GPP Name

P0

3GPP Reference

3GPP TS 44.060 V5.19.0


P0 is an optional parameter for downlink power control. It is included
in PACKET UPLINK ASSIGNMENT and PACKET DOWNLINK ASSIGNMENT messages. If P0 is included in the assignment, power control is
used. Otherwise, it is not used. The value of P0 can not be modified in
packet transmission mode unless a re-assignment or a new assignment
is established and such an assignment does not contain PDCH(s) of any

Description

previous assignment.

Managed Object

Cell
0..15
0: P0 = 0 dB;
1: P0 = 2 dB;
...
15: P0 = 30 dB

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional parameter, which is disabled by default.

Configuration Rule and

higher the P0 value, the lower the BTS transmission power; the lower

Adjustment Suggestion

the P0 value, the higher the BTS transmission power. Set it based on

The parameter is used when downlink power control is enabled. The

the actual condition.


Change Mode

Offline

Related features

ZGO-03-02-008 EGPRS on BCCH-TRX Configurable

5-143
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.2.6.7 Max power reduction of CS1 (CodePwrDecLmt0)


Full Name

Max power reduction of CS1

Abbreviation

CodePwrDecLmt0

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum decreased power during power

Description

control when the service encoding mode is CS1.

Managed Object

Cell

Value Range and Step

0..40

Unit

db

Default Value

26

Default Value

The maximum signal strength supported by the encoding mode must be

Configuration Reason

taken into consideration.

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the QoS will be affected. If


this parameter is configured too smaller, the range for power control
adjustment will be restricted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

5-144
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.8 Max power reduction of CS2 (CodePwrDecLmt1)


Full Name

Max power reduction of CS2

Abbreviation

CodePwrDecLmt1

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum decreased power during power

Description

control when the service encoding mode is CS2.

Managed Object

Cell

Value Range and Step

0..40

Unit

db

Default Value

20

Default Value

The maximum signal strength supported by the encoding mode must be

Configuration Reason

taken into consideration.

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the QoS will be affected. If


this parameter is configured too smaller, the range for power control
adjustment will be restricted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

0
5-145

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.9 Max power reduction of CS3 (CodePwrDecLmt2)


Full Name

Max power reduction of CS3

Abbreviation

CodePwrDecLmt2

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum decreased power during power

Description

control when the service encoding mode is CS3.

Managed Object

Cell

Value Range and Step

0..40

Unit

db

Default Value

16

Default Value

The maximum signal strength supported by the encoding mode must be

Configuration Reason

taken into consideration.

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the QoS will be affected. If


this parameter is configured too smaller, the range for power control
adjustment will be restricted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-146
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.10 Max power reduction of CS4 (CodePwrDecLmt3)


Full Name

Max power reduction of CS4

Abbreviation

CodePwrDecLmt3

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum decreased power during power

Description

control when the service encoding mode is CS4.

Managed Object

Cell

Value Range and Step

0..40

Unit

db

Default Value

12

Default Value

The maximum signal strength supported by the encoding mode must be

Configuration Reason

taken into consideration.

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the QoS will be affected. If


this parameter is configured too smaller, the range for power control
adjustment will be restricted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

5-147
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.11 Max power reduction of MCS1 (CodePwrDecLmt4)


Full Name

Max power reduction of MCS1

Abbreviation

CodePwrDecLmt4

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum decreased power during power

Description

control when the service encoding mode is MCS1.

Managed Object

Cell

Value Range and Step

0..40

Unit

db

Default Value

26

Default Value

The maximum signal strength supported by the encoding mode must be

Configuration Reason

taken into consideration.

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the QoS will be affected. If


this parameter is configured too smaller, the range for power control
adjustment will be restricted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

5-148
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

New

5.2.6.12 Max power reduction of MCS2 (CodePwrDecLmt5)


Full Name

Max power reduction of MCS2

Abbreviation

CodePwrDecLmt5

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum decreased power during power

Description

control when the service encoding mode is MCS2.

Managed Object

Cell

Value Range and Step

0..40

Unit

db

Default Value

24

Default Value

The maximum signal strength supported by the encoding mode must be

Configuration Reason

taken into consideration.

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the QoS will be affected. If


this parameter is configured too smaller, the range for power control
adjustment will be restricted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-149
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.13 Max power reduction of MCS3 (CodePwrDecLmt6)


Full Name

Max power reduction of MCS3

Abbreviation

CodePwrDecLmt6

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum decreased power during power

Description

control when the service encoding mode is MCS3.

Managed Object

Cell

Value Range and Step

0..40

Unit

db

Default Value

22

Default Value

The maximum signal strength supported by the encoding mode must be

Configuration Reason

taken into consideration.

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the QoS will be affected. If


this parameter is configured too smaller, the range for power control
adjustment will be restricted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.14 Max power reduction of MCS4 (CodePwrDecLmt7)


Full Name

Max power reduction of MCS4

Abbreviation

CodePwrDecLmt7
5-150

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum decreased power during power

Description

control when the service encoding mode is MCS4.

Managed Object

Cell

Value Range and Step

0..40

Unit

db

Default Value

20

Default Value

The maximum signal strength supported by the encoding mode must be

Configuration Reason

taken into consideration.

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the QoS will be affected. If


this parameter is configured too smaller, the range for power control
adjustment will be restricted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.15 Max power reduction of MCS5 (CodePwrDecLmt8)


Full Name

Max power reduction of MCS5

Abbreviation

CodePwrDecLmt8

3GPP Name

None

3GPP Reference

None

5-151
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines the maximum decreased power during power


Description

control when the service encoding mode is MCS5.

Managed Object

Cell

Value Range and Step

0..40

Unit

db

Default Value

18

Default Value

The maximum signal strength supported by the encoding mode must be

Configuration Reason

taken into consideration.

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the QoS will be affected. If


this parameter is configured too smaller, the range for power control
adjustment will be restricted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.16 Max power reduction of MCS6 (CodePwrDecLmt9)


Full Name

Max power reduction of MCS6

Abbreviation

CodePwrDecLmt9

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum decreased power during power

Description

control when the service encoding mode is MCS6.

Managed Object

Cell

5-152
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Value Range and Step

0..40

Unit

db

Default Value

16

Default Value

The maximum signal strength supported by the encoding mode must be

Configuration Reason

taken into consideration.

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the QoS will be affected. If


this parameter is configured too smaller, the range for power control
adjustment will be restricted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.17 Max power reduction of MCS7 (CodePwrDecLmt10)


Full Name

Max power reduction of MCS7

Abbreviation

CodePwrDecLmt10

3GPP Name

None

3GPP Reference

None

Description

control when the service encoding mode is MCS7.

Managed Object

Cell

Value Range and Step

0..40

Unit

db

Default Value

14

This parameter determines the maximum decreased power during power

5-153
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

The maximum signal strength supported by the encoding mode must be

Configuration Reason

taken into consideration.

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the QoS will be affected. If


this parameter is configured too smaller, the range for power control
adjustment will be restricted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.18 Max power reduction of MCS8 (CodePwrDecLmt11)


Full Name

Max power reduction of MCS8

Abbreviation

CodePwrDecLmt11

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum decreased power during power

Description

control when the service encoding mode is MCS8.

Managed Object

Cell

Value Range and Step

0..40

Unit

db

Default Value

12

Default Value

The maximum signal strength supported by the encoding mode must be

Configuration Reason

taken into consideration.

5-154
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the QoS will be affected. If


this parameter is configured too smaller, the range for power control
adjustment will be restricted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.19 Max power reduction of MCS9 (CodePwrDecLmt12)


Full Name

Max power reduction of MCS9

Abbreviation

CodePwrDecLmt12

3GPP Name

None

3GPP Reference

None
This parameter determines the maximum decreased power during power

Description

control when the service encoding mode is MCS9.

Managed Object

Cell

Value Range and Step

0..40

Unit

db

Default Value

10

Default Value

The maximum signal strength supported by the encoding mode must be

Configuration Reason

taken into consideration.

Configuration Rule and


Adjustment Suggestion

If this parameter is configured too large, the QoS will be affected. If


this parameter is configured too smaller, the range for power control
adjustment will be restricted.

5-155
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.20 Uplink power level Sample count (PSPwrMeaWindow0)


Full Name

Uplink power level Sample count

Abbreviation

PSPwrMeaWindow0

3GPP Name

None

3GPP Reference

None
This parameter determines the number of samples used for average calculation on the uplink signal strength measured during uplink power con-

Description

trol judgment.

Managed Object

Cell

Value Range and Step

1..31

Unit

None

Default Value

10

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The larger the value of this parameter, the more the number of samples
required for average calculation and thus the smaller the fluctuation of

Configuration Rule and


Adjustment Suggestion

the average value. However, the sensitivity decreases. The smaller the
value of this parameter, the less the number of samples required for
average calculation and thus the higher the sensitivity. However, the
fluctuation of the average value is large.
5-156

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.21 Downlink power level Sample count (PSPwrMeaWindow1)


Full Name

Downlink power level Sample count

Abbreviation

PSPwrMeaWindow1

3GPP Name

None

3GPP Reference

None
This parameter determines the number of samples used for average calculation on the downlink signal strength measured during downlink power

Description

control judgment.

Managed Object

Cell

Value Range and Step

1..31

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The larger the value of this parameter, the more the number of samples
required for average calculation and thus the smaller the fluctuation of

Configuration Rule and


Adjustment Suggestion

the average value. However, the sensitivity decreases. The smaller the
value of this parameter, the less the number of samples required for
average calculation and thus the higher the sensitivity. However, the
fluctuation of the average value is large.
5-157

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.22 Uplink quality Sample count (PSPwrMeaWindow2)


Full Name

Uplink quality Sample count

Abbreviation

PSPwrMeaWindow2

3GPP Name

None

3GPP Reference

None
This parameter determines the number of samples used for average calculation on the uplink signal quality measured during uplink power control

Description

judgment.

Managed Object

Cell

Value Range and Step

1..31

Unit

None

Default Value

10

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The larger the value of this parameter, the more the number of samples
required for average calculation and thus the smaller the fluctuation of

Configuration Rule and


Adjustment Suggestion

the average value. However, the sensitivity decreases. The smaller the
value of this parameter, the less the number of samples required for
average calculation and thus the higher the sensitivity. However, the
fluctuation of the average value is large.
5-158

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.23 Downlink quality Sample count (PSPwrMeaWindow3)


Full Name

Downlink quality Sample count

Abbreviation

PSPwrMeaWindow3

3GPP Name

None

3GPP Reference

None
This parameter determines the number of samples used for average calculation on the downlink signal quality measured during downlink power

Description

control judgment.

Managed Object

Cell

Value Range and Step

1..31

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The larger the value of this parameter, the more the number of samples
required for average calculation and thus the smaller the fluctuation of

Configuration Rule and


Adjustment Suggestion

the average value. However, the sensitivity decreases. The smaller the
value of this parameter, the less the number of samples required for
average calculation and thus the higher the sensitivity. However, the
fluctuation of the average value is large.
5-159

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.24 Step of uplink power increase (PSPwrChgStep0)


Full Name

Step of uplink power increase

Abbreviation

PSPwrChgStep0

3GPP Name

None

3GPP Reference

None
This parameter determines the step of power increase during uplink power

Description

control.

Managed Object

Cell

Value Range and Step

2,4

Unit

db

Default Value

Default Value

The power adjusted each time must not be too large, so as to avoid

Configuration Reason

fluctuation.
The smaller the value of this parameter, the smaller the power increased

Configuration Rule and

and thus the smoother the adjustment. The larger the value of this

Adjustment Suggestion

parameter, the larger the power increased and thus the faster the
adjustment. However, this is easy to cause fluctuation.

Change Mode

Offline

Related features

None

5-160
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.25 Step of uplink power decrease (PSPwrChgStep1)


Full Name

Step of uplink power decrease

Abbreviation

PSPwrChgStep1

3GPP Name

None

3GPP Reference

None
This parameter determines the step of power decrease during uplink

Description

power control.

Managed Object

Cell

Value Range and Step

2,4

Unit

db

Default Value

Default Value

The power adjusted each time must not be too large, so as to avoid

Configuration Reason

fluctuation.
The smaller the value of this parameter, the smaller the power decreased

Configuration Rule and

and thus the smoother the adjustment. The larger the value of this

Adjustment Suggestion

parameter, the larger the power decreased and thus the faster the
adjustment. However, this is easy to cause fluctuation.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

5-161
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.26 Step of downlink power increase (PSPwrChgStep2)


Full Name

Step of downlink power increase

Abbreviation

PSPwrChgStep2

3GPP Name

None

3GPP Reference

None
This parameter determines the step of power increase during downlink

Description

power control.

Managed Object

Cell
1: 0.5db
2: 1db
3: 1.5db
4: 2db
5: 2.5db
6: 3db
7: 3.5db

Value Range and Step

8: 4db

Unit

db

Default Value

Default Value

The power adjusted each time must not be too large, so as to avoid

Configuration Reason

fluctuation.
The smaller the value of this parameter, the smaller the power increased

Configuration Rule and

and thus the smoother the adjustment. The larger the value of this

Adjustment Suggestion

parameter, the larger the power increased and thus the faster the
adjustment. However, this is easy to cause fluctuation.

Change Mode

Offline
5-162

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.27 Step of downlink power decrease (PSPwrChgStep3)


Full Name

Step of downlink power decrease

Abbreviation

PSPwrChgStep3

3GPP Name

None

3GPP Reference

None
This parameter determines the step of power decrease during downlink

Description

power control.

Managed Object

Cell
1: 0.5db
2: 1db
3: 1.5db
4: 2db
5: 2.5db
6: 3db
7: 3.5db

Value Range and Step

8: 4db

Unit

db

Default Value

Default Value

The power adjusted each time must not be too large, so as to avoid

Configuration Reason

fluctuation.

5-163
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The smaller the value of this parameter, the smaller the power decreased
Configuration Rule and

and thus the smoother the adjustment. The larger the value of this

Adjustment Suggestion

parameter, the larger the power decreased and thus the faster the
adjustment. However, this is easy to cause fluctuation.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.28 Threshold of uplink signal for increasing power (PSPwrChgThr0)


Full Name

Threshold of uplink signal for increasing power

Abbreviation

PSPwrChgThr0

3GPP Name

None

3GPP Reference

None
When P out of N uplink signal strength averages are lower than this
threshold during uplink power control judgment, the system considers

Description

this case as low level.

Managed Object

Cell
20: -90dBm
21: -89dBm
22: -88dBm
....

Value Range and Step

30: -80dBm

Unit

dBm

Default Value

22

5-164
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

The signal strength for normal operation of the PS service must be

Configuration Reason

taken into consideration.


The larger the value of this parameter, the higher the possibility of

Configuration Rule and


Adjustment Suggestion

being considered as low level and thus the higher the possibility of
power increase during power judgment. The smaller the value of this
parameter, the lower the possibility of being considered as low level and
thus the lower the possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.29 Threshold of downlink signal for increasing power (PSPwrChgThr1)


Full Name

Threshold of downlink signal for increasing power

Abbreviation

PSPwrChgThr1

3GPP Name

None

3GPP Reference

None
When P out of N downlink signal strength averages are lower than this
threshold during downlink power control judgment, the system considers

Description

this case as low level.

Managed Object

Cell

5-165
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

20: -90dBm
21: -89dBm
22: -88dBm
....
Value Range and Step

30: -80dBm

Unit

dBm

Default Value

22

Default Value

The signal strength for normal operation of the PS service must be

Configuration Reason

taken into consideration.


The larger the value of this parameter, the higher the possibility of

Configuration Rule and


Adjustment Suggestion

being considered as low level and thus the higher the possibility of
power increase during power judgment. The smaller the value of this
parameter, the lower the possibility of being considered as low level and
thus the lower the possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.30 Threshold of uplink signal for decreasing power (PSPwrChgThr2)


Full Name

Threshold of uplink signal for decreasing power

Abbreviation

PSPwrChgThr2

3GPP Name

None

3GPP Reference

None

5-166
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

When P out of N uplink signal strength averages are higher than this
threshold during uplink power control judgment, the system considers this
Description

case as high level.

Managed Object

Cell
32: -78dBm
33: -77dBm
34: -76dBm
....

Value Range and Step

45: -65dBm

Unit

dBm

Default Value

36

Default Value

The signal strength for normal operation of the PS service must be

Configuration Reason

taken into consideration.


The smaller the value of this parameter, the higher the possibility of

Configuration Rule and


Adjustment Suggestion

being considered as high level and thus the higher the possibility of
power decrease during power judgment. The larger the value of this
parameter, the lower the possibility of being considered as high level and
thus the lower the possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.31 Threshold of downlink signal for decreasing power (PSPwrChgThr3)


Full Name

Threshold of downlink signal for decreasing power

5-167
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

PSPwrChgThr3

3GPP Name

None

3GPP Reference

None
When P out of N downlink signal strength averages are higher than this
threshold during downlink power control judgment, the system considers

Description

this case as high level.

Managed Object

Cell
32: -78dBm
33: -77dBm
34: -76dBm
....

Value Range and Step

45: -65dBm

Unit

dBm

Default Value

40

Default Value

The signal strength for normal operation of the PS service must be

Configuration Reason

taken into consideration.


The smaller the value of this parameter, the higher the possibility of

Configuration Rule and


Adjustment Suggestion

being considered as high level and thus the higher the possibility of
power decrease during power judgment. The larger the value of this
parameter, the lower the possibility of being considered as high level and
thus the lower the possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-168
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.32 Threshold of uplink MEAN_BEP for increasing power in GPRS


(PSPwrChgThr4)
Full Name

Threshold of uplink MEAN_BEP for increasing power in GPRS

Abbreviation

PSPwrChgThr4

3GPP Name

None

3GPP Reference

None
When P out of N uplink MEAN_BEP averages are lower than this threshold during uplink power control judgment, the system considers this case

Description

as low quality.

Managed Object

Cell

Value Range and Step

12..24

Unit

None

Default Value

18

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The larger the value of this parameter, the higher the possibility of being

Configuration Rule and


Adjustment Suggestion

considered as low quality and thus the higher the possibility of power
increase during power judgment. The smaller the value of this parameter,
the lower the possibility of being considered as low quality and thus the
lower the possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-169
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.33 Threshold of uplink CV_BEP for increasing power in GPRS (PSPwrChgThr5)


Full Name

Threshold of uplink CV_BEP for increasing power in GPRS

Abbreviation

PSPwrChgThr5

3GPP Name

None

3GPP Reference

None
When P out of N uplink CV_BEP averages are lower than this threshold
during uplink power control judgment, the system considers this case as

Description

low quality. This parameter is currently not available.

Managed Object

Cell

Value Range and Step

2..5

Unit

None

Default Value

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The larger the value of this parameter, the higher the possibility of being

Configuration Rule and


Adjustment Suggestion

considered as low quality and thus the higher the possibility of power
increase during power judgment. The smaller the value of this parameter,
the lower the possibility of being considered as low quality and thus the
lower the possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-170
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.34 Threshold of downlink quality for increasing power in GPRS (PSPwrChgThr6)


Full Name

Threshold of downlink quality for increasing power in GPRS

Abbreviation

PSPwrChgThr6

3GPP Name

None

3GPP Reference

None
When P out of N downlink quality averages are higher than this threshold
during downlink power control judgment of the GPRS service, the system

Description

considers this case as low quality.

Managed Object

Cell

Value Range and Step

2..5

Unit

None

Default Value

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The smaller the value of this parameter, the higher the possibility of being

Configuration Rule and


Adjustment Suggestion

considered as low quality and thus the higher the possibility of power
increase during power judgment. The larger the value of this parameter,
the lower the possibility of being considered as low quality and thus the
lower the possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-171
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.35 Threshold of uplink MEAN_BEP for decreasing power in GPRS


(PSPwrChgThr7)
Full Name

Threshold of uplink MEAN_BEP for decreasing power in GPRS

Abbreviation

PSPwrChgThr7

3GPP Name

None

3GPP Reference

None
When P out of N uplink MEAN_BEP averages are higher than this threshold during uplink power control judgment of the GPRS service, the system

Description

considers this case as high quality.

Managed Object

Cell

Value Range and Step

27..30

Unit

None

Default Value

29

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The smaller the value of this parameter, the higher the possibility of being

Configuration Rule and


Adjustment Suggestion

considered as high quality and thus the higher the possibility of power
decrease during power judgment. The larger the value of this parameter,
the lower the possibility of being considered as high quality and thus the
lower the possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-172
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.36 Threshold of uplink CV_BEP for decreasing power in GPRS (PSPwrChgThr8)


Full Name

Threshold of uplink CV_BEP for decreasing power in GPRS

Abbreviation

PSPwrChgThr8

3GPP Name

None

3GPP Reference

None
When P out of N uplink CV_BEP averages are higher than this threshold
and P out of N uplink MEAN_BEP averages are higher than the corresponding MEAN_BEP threshold during uplink power control judgment of
the GPRS service, the system considers this case as high quality. This

Description

parameter is currently not available.

Managed Object

Cell

Value Range and Step

5..6

Unit

None

Default Value

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The smaller the value of this parameter, the higher the possibility of being

Configuration Rule and


Adjustment Suggestion

considered as high quality and thus the higher the possibility of power
decrease during power judgment. The larger the value of this parameter,
the lower the possibility of being considered as high quality and thus the
lower the possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-173
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.37 Threshold of downlink quality for decreasing power in GPRS (PSPwrChgTh9)


Full Name

Threshold of downlink quality for decreasing power in GPRS

Abbreviation

PSPwrChgTh9

3GPP Name

None

3GPP Reference

None
When P out of N downlink quality averages are lower than this threshold
during downlink power control judgment of the GPRS service, the system

Description

considers this case as high quality.

Managed Object

Cell

Value Range and Step

1..2

Unit

None

Default Value

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The larger the value of this parameter, the higher the possibility of
being considered as high quality and thus the higher the possibility of

Configuration Rule and

power decrease during power judgment. The smaller the value of this

Adjustment Suggestion

parameter, the lower the possibility of being considered as high quality


and thus the lower the possibility of power decrease during power
judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-174
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.38 Threshold of uplink MEAN_BEP for increasing power in EDGE


(PSPwrChgThr10)
Full Name

Threshold of uplink MEAN_BEP for increasing power in EDGE

Abbreviation

PSPwrChgThr10

3GPP Name

None

3GPP Reference

None
When P out of N uplink MEAN_BEP averages are lower than this threshold during uplink power control judgment of the EDGE service, the system

Description

considers this case as low quality.

Managed Object

Cell

Value Range and Step

12..24

Unit

None

Default Value

18

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The larger the value of this parameter, the higher the possibility of being

Configuration Rule and


Adjustment Suggestion

considered as low quality and thus the higher the possibility of power
increase during power judgment. The smaller the value of this parameter,
the lower the possibility of being considered as low quality and thus the
lower the possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-175
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.39 Threshold of uplink CV_BEP for increasing power in EDGE (PSPwrChgThr11)


Full Name

Threshold of uplink CV_BEP for increasing power in EDGE

Abbreviation

PSPwrChgThr11

3GPP Name

None

3GPP Reference

None
When P out of N uplink CV_BEP averages are lower than this threshold
during uplink power control judgment of the EDGE service, the system
considers this case as low quality. This parameter is currently not avail-

Description

able.

Managed Object

Cell

Value Range and Step

2..5

Unit

None

Default Value

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The larger the value of this parameter, the higher the possibility of being

Configuration Rule and


Adjustment Suggestion

considered as low quality and thus the higher the possibility of power
increase during power judgment. The smaller the value of this parameter,
the lower the possibility of being considered as low quality and thus the
lower the possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-176
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.40 Threshold of downlink MEAN_BEP for increasing power in EDGE


(PSPwrChgThr12)
Full Name

Threshold of downlink MEAN_BEP for increasing power in EDGE

Abbreviation

PSPwrChgThr12

3GPP Name

None

3GPP Reference

None
When P out of N downlink quality averages are lower than this threshold
during downlink power control judgment of the EDGE service, the system

Description

considers this case as low quality.

Managed Object

Cell

Value Range and Step

12..24

Unit

None

Default Value

18

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The larger the value of this parameter, the higher the possibility of being

Configuration Rule and


Adjustment Suggestion

considered as low quality and thus the higher the possibility of power
increase during power judgment. The smaller the value of this parameter,
the lower the possibility of being considered as low quality and thus the
lower the possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-177
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.41 Threshold of downlink CV_BEP for increasing power in EDGE


(PSPwrChgThr13)
Full Name

Threshold of downlink CV_BEP for increasing power in EDGE

Abbreviation

PSPwrChgThr13

3GPP Name

None

3GPP Reference

None
When P out of N downlink CV_BEP averages are lower than this threshold
during downlink power control judgment of the EDGE service, the system
considers this case as high quality. This parameter is currently not avail-

Description

able.

Managed Object

Cell

Value Range and Step

2..5

Unit

None

Default Value

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The larger the value of this parameter, the higher the possibility of being

Configuration Rule and


Adjustment Suggestion

considered as low quality and thus the higher the possibility of power
increase during power judgment. The smaller the value of this parameter,
the lower the possibility of being considered as low quality and thus the
lower the possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-178
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.42 Threshold of uplink MEAN_BEP for decreasing power in EDGE


(PSPwrChgThr14)
Full Name

Threshold of uplink MEAN_BEP for decreasing power in EDGE

Abbreviation

PSPwrChgThr14

3GPP Name

None

3GPP Reference

None
When P out of N uplink MEAN_BEP averages are higher than this threshold during uplink power control judgment of the EDGE service, the system

Description

considers this case as high quality.

Managed Object

Cell

Value Range and Step

27..30

Unit

None

Default Value

29

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The smaller the value of this parameter, the higher the possibility of being

Configuration Rule and


Adjustment Suggestion

considered as high quality and thus the higher the possibility of power
decrease during power judgment. The larger the value of this parameter,
the lower the possibility of being considered as high quality and thus the
lower the possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-179
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.43 Threshold of uplink CV_BEP for decreasing power in EDGE (PSPwrChgThr15)


Full Name

Threshold of uplink CV_BEP for decreasing power in EDGE

Abbreviation

PSPwrChgThr15

3GPP Name

None

3GPP Reference

None
When P out of N uplink CV_BEP averages are higher than this threshold
and P out of N uplink MEAN_BEP averages are higher than the corresponding MEAN_BEP threshold during uplink power control judgment of
the EDGE service, the system considers this case as high quality. This

Description

parameter is currently not available.

Managed Object

Cell

Value Range and Step

5..6

Unit

None

Default Value

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The smaller the value of this parameter, the higher the possibility of being

Configuration Rule and


Adjustment Suggestion

considered as high quality and thus the higher the possibility of power
decrease during power judgment. The larger the value of this parameter,
the lower the possibility of being considered as high quality and thus the
lower the possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-180
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.44 Threshold of downlink MEAN_BEP for decreasing power in EDGE


(PSPwrChgThr16)
Full Name

Threshold of downlink MEAN_BEP for decreasing power in EDGE

Abbreviation

PSPwrChgThr16

3GPP Name

None

3GPP Reference

None
When P out of N downlink MEAN_BEP averages are higher than this
threshold during downlink power control judgment of the EDGE service,

Description

the system considers this case as high quality.

Managed Object

Cell

Value Range and Step

27..30

Unit

None

Default Value

29

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The smaller the value of this parameter, the higher the possibility of being

Configuration Rule and


Adjustment Suggestion

considered as high quality and thus the higher the possibility of power
decrease during power judgment. The larger the value of this parameter,
the lower the possibility of being considered as high quality and thus the
lower the possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-181
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.45 Threshold of downlink CV_BEP for decreasing power in EDGE


(PSPwrChgThr17)
Full Name

Threshold of downlink CV_BEP for decreasing power in EDGE

Abbreviation

PSPwrChgThr17

3GPP Name

None

3GPP Reference

None
When P out of N downlink CV_BEP averages are higher than this threshold and P out of N downlink MEAN_BEP averages are higher than the
corresponding MEAN_BEP threshold during downlink power control judgment of the EDGE service, the system considers this case as high quality.

Description

This parameter is currently not available.

Managed Object

Cell

Value Range and Step

5..6

Unit

None

Default Value

Default Value

The quality for normal operation of the PS service must be taken into

Configuration Reason

consideration.
The smaller the value of this parameter, the higher the possibility of being

Configuration Rule and


Adjustment Suggestion

considered as high quality and thus the higher the possibility of power
decrease during power judgment. The larger the value of this parameter,
the lower the possibility of being considered as high quality and thus the
lower the possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-182
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.46 N of uplink signal for increasing power (PSPwrChgN0)


Full Name

N of uplink signal for increasing power

Abbreviation

PSPwrChgN0

3GPP Name

None

3GPP Reference

None
When P out of N uplink signal strength averages are lower than this
threshold during uplink power control judgment, the system considers

Description

this case as low level.

Managed Object

Cell

Value Range and Step

5..50

Unit

None

Default Value

30

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The larger the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power increase
during power judgment. The smaller the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-183
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.47 N of downlink signal for increasing power (PSPwrChgN1)


Full Name

N of downlink signal for increasing power

Abbreviation

PSPwrChgN1

3GPP Name

None

3GPP Reference

None
When P out of N downlink signal strength averages are lower than this
threshold during downlink power control judgment, the system considers

Description

this case as low level.

Managed Object

Cell

Value Range and Step

2..15

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The larger the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power increase
during power judgment. The smaller the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-184
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.48 N of uplink signal for decreasing power (PSPwrChgN2)


Full Name

N of uplink signal for decreasing power

Abbreviation

PSPwrChgN2

3GPP Name

None

3GPP Reference

None
When P out of N uplink signal strength averages are higher than this
threshold during uplink power control judgment, the system considers this

Description

case as high level.

Managed Object

Cell

Value Range and Step

5..50

Unit

None

Default Value

30

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The larger the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power decrease
during power judgment. The smaller the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-185
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.49 N of downlink signal for decreasing power (PSPwrChgN3)


Full Name

N of downlink signal for decreasing power

Abbreviation

PSPwrChgN3

3GPP Name

None

3GPP Reference

None
When P out of N downlink signal strength averages are higher than this
threshold during downlink power control judgment, the system considers

Description

this case as high level.

Managed Object

Cell

Value Range and Step

2..15

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The larger the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power decrease
during power judgment. The smaller the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-186
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.50 N of uplink quality for increasing power in GPRS (PSPwrChgN4)


Full Name

N of uplink quality for increasing power in GPRS

Abbreviation

PSPwrChgN4

3GPP Name

None

3GPP Reference

None
When P out of N uplink quality averages are lower than this threshold
during uplink power control judgment of the GPRS service, the system

Description

considers this case as low quality.

Managed Object

Cell

Value Range and Step

5..50

Unit

None

Default Value

30

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The larger the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power increase
during power judgment. The smaller the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-187
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.51 N of downlink quality for increasing power in GPRS (PSPwrChgN5)


Full Name

N of downlink quality for increasing power in GPRS

Abbreviation

PSPwrChgN5

3GPP Name

None

3GPP Reference

None
When P out of N downlink quality averages are higher than this threshold
during downlink power control judgment of the GPRS service, the system

Description

considers this case as low quality.

Managed Object

Cell

Value Range and Step

2..15

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The larger the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power increase
during power judgment. The smaller the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-188
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.52 N of uplink quality for decreasing power in GPRS (PSPwrChgN6)


Full Name

N of uplink quality for decreasing power in GPRS

Abbreviation

PSPwrChgN6

3GPP Name

None

3GPP Reference

None
When P out of N uplink quality averages are higher than this threshold
during uplink power control judgment of the GPRS service, the system

Description

considers this case as high quality.

Managed Object

Cell

Value Range and Step

5..50

Unit

None

Default Value

30

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The larger the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power decrease
during power judgment. The smaller the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-189
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.53 N of downlink quality for decreasing power in GPRS (PSPwrChgN7)


Full Name

N of downlink quality for decreasing power in GPRS

Abbreviation

PSPwrChgN7

3GPP Name

None

3GPP Reference

None
When P out of N downlink quality averages are lower than this threshold
during downlink power control judgment of the GPRS service, the system

Description

considers this case as high quality.

Managed Object

Cell

Value Range and Step

2..15

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The larger the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power decrease
during power judgment. The smaller the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-190
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.54 N of uplink quality for increasing power in EDGE (PSPwrChgN8)


Full Name

N of uplink quality for increasing power in EDGE

Abbreviation

PSPwrChgN8

3GPP Name

None

3GPP Reference

None
When P out of N uplink quality averages are lower than this threshold
during uplink power control judgment of the EDGE service, the system

Description

considers this case as low quality.

Managed Object

Cell

Value Range and Step

5..50

Unit

None

Default Value

30

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The larger the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power increase
during power judgment. The smaller the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-191
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.55 N of downlink quality for increasing power in EDGE (PSPwrChgN9)


Full Name

N of downlink quality for increasing power in EDGE

Abbreviation

PSPwrChgN9

3GPP Name

None

3GPP Reference

None
When P out of N downlink quality averages are lower than this threshold
during downlink power control judgment of the EDGE service, the system

Description

considers this case as low quality.

Managed Object

Cell

Value Range and Step

2..15

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The larger the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power increase
during power judgment. The smaller the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-192
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.56 N of uplink quality for decreasing power in EDGE (PSPwrChgN10)


Full Name

N of uplink quality for decreasing power in EDGE

Abbreviation

PSPwrChgN10

3GPP Name

None

3GPP Reference

None
When P out of N uplink quality averages are higher than this threshold
during uplink power control judgment of the EDGE service, the system

Description

considers this case as high quality.

Managed Object

Cell

Value Range and Step

5..50

Unit

None

Default Value

30

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The larger the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power decrease
during power judgment. The smaller the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-193
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.57 N of downlink quality for decreasing power in EDGE (PSPwrChgN11)


Full Name

N of downlink quality for decreasing power in EDGE

Abbreviation

PSPwrChgN11

3GPP Name

None

3GPP Reference

None
When P out of N downlink quality averages are higher than this threshold
during downlink power control judgment of the EDGE service, the system

Description

considers this case as high quality.

Managed Object

Cell

Value Range and Step

2..15

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The larger the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power decrease
during power judgment. The smaller the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-194
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.58 P of uplink signal for increasing power (PSPwrChgP0)


Full Name

P of uplink signal for increasing power

Abbreviation

PSPwrChgP0

3GPP Name

None

3GPP Reference

None
When P out of N uplink signal strength averages are lower than this
threshold during uplink power control judgment, the system considers

Description

this case as low level.

Managed Object

Cell

Value Range and Step

5..50

Unit

None

Default Value

25

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The smaller the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power increase
during power judgment. The larger the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-195
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.59 P of downlink signal for increasing power (PSPwrChgP1)


Full Name

P of downlink signal for increasing power

Abbreviation

PSPwrChgP1

3GPP Name

None

3GPP Reference

None
When P out of N downlink signal strength averages are lower than this
threshold during downlink power control judgment, the system considers

Description

this case as low level.

Managed Object

Cell

Value Range and Step

2..15

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The smaller the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power increase
during power judgment. The larger the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-196
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.60 P of uplink signal for decreasing power (PSPwrChgP2)


Full Name

P of uplink signal for decreasing power

Abbreviation

PSPwrChgP2

3GPP Name

None

3GPP Reference

None
When P out of N uplink signal strength averages are higher than this
threshold during uplink power control judgment, the system considers this

Description

case as high level.

Managed Object

Cell

Value Range and Step

5..50

Unit

None

Default Value

25

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The smaller the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power decrease
during power judgment. The larger the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-197
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.61 P of downlink signal for decreasing power (PSPwrChgP3)


Full Name

P of downlink signal for decreasing power

Abbreviation

PSPwrChgP3

3GPP Name

None

3GPP Reference

None
When P out of N downlink signal strength averages are higher than this
threshold during downlink power control judgment, the system considers

Description

this case as high level.

Managed Object

Cell

Value Range and Step

2..15

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The smaller the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power decrease
during power judgment. The larger the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-198
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.62 P of uplink quality for increasing power in GPRS (PSPwrChgP4)


Full Name

P of uplink quality for increasing power in GPRS

Abbreviation

PSPwrChgP4

3GPP Name

None

3GPP Reference

None
When P out of N uplink quality averages are lower than this threshold
during uplink power control judgment of the GPRS service, the system

Description

considers this case as low quality.

Managed Object

Cell

Value Range and Step

5..50

Unit

None

Default Value

30

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The smaller the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power increase
during power judgment. The larger the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-199
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.63 P of downlink quality for increasing power in GPRS (PSPwrChgP5)


Full Name

P of downlink quality for increasing power in GPRS

Abbreviation

PSPwrChgP5

3GPP Name

None

3GPP Reference

None
When P out of N downlink quality averages are higher than this threshold
during downlink power control judgment of the GPRS service, the system

Description

considers this case as low quality.

Managed Object

Cell

Value Range and Step

2..15

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The smaller the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power increase
during power judgment. The larger the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-200
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.64 P of uplink quality for decreasing power in GPRS (PSPwrChgP6)


Full Name

P of uplink quality for decreasing power in GPRS

Abbreviation

PSPwrChgP6

3GPP Name

None

3GPP Reference

None
When P out of N uplink quality averages are higher than this threshold
during uplink power control judgment of the GPRS service, the system

Description

considers this case as high quality.

Managed Object

Cell

Value Range and Step

5..50

Unit

None

Default Value

25

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The smaller the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power decrease
during power judgment. The larger the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-201
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.65 P of downlink quality for decreasing power in GPRS (PSPwrChgP7)


Full Name

P of downlink quality for decreasing power in GPRS

Abbreviation

PSPwrChgP7

3GPP Name

None

3GPP Reference

None
When P out of N downlink quality averages are lower than this threshold
during downlink power control judgment of the GPRS service, the system

Description

considers this case as high quality.

Managed Object

Cell

Value Range and Step

2..15

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The smaller the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power decrease
during power judgment. The larger the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-202
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.66 P of uplink quality for increasing power in EDGE (PSPwrChgP8)


Full Name

P of uplink quality for increasing power in EDGE

Abbreviation

PSPwrChgP8

3GPP Name

None

3GPP Reference

None
When P out of N uplink quality averages are lower than this threshold
during uplink power control judgment of the EDGE service, the system

Description

considers this case as low quality.

Managed Object

Cell

Value Range and Step

5..50

Unit

None

Default Value

25

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The smaller the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power increase
during power judgment. The larger the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-203
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.67 P of downlink quality for increasing power in EDGE (PSPwrChgP9)


Full Name

P of downlink quality for increasing power in EDGE

Abbreviation

PSPwrChgP9

3GPP Name

None

3GPP Reference

None
When P out of N downlink quality averages are lower than this threshold
during downlink power control judgment of the EDGE service, the system

Description

considers this case as low quality.

Managed Object

Cell

Value Range and Step

2..15

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The smaller the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power increase
during power judgment. The larger the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power increase during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-204
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.68 P of uplink quality for decreasing power in EDGE (PSPwrChgP10)


Full Name

P of uplink quality for decreasing power in EDGE

Abbreviation

PSPwrChgP10

3GPP Name

None

3GPP Reference

None
When P out of N uplink quality averages are higher than this threshold
during uplink power control judgment of the EDGE service, the system

Description

considers this case as high quality.

Managed Object

Cell

Value Range and Step

5..50

Unit

None

Default Value

25

Default Value

In the uplink direction, the measurement report is reported quickly.

Configuration Reason

Therefore, each radio module can report it once.


The smaller the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power decrease
during power judgment. The larger the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-205
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.69 P of downlink quality for decreasing power in EDGE (PSPwrChgP11)


Full Name

P of downlink quality for decreasing power in EDGE

Abbreviation

PSPwrChgP11

3GPP Name

None

3GPP Reference

None
When P out of N downlink quality averages are higher than this threshold
during downlink power control judgment of the EDGE service, the system

Description

considers this case as high quality.

Managed Object

Cell

Value Range and Step

2..15

Unit

None

Default Value

Default Value

In the downlink direction, the measurement report is reported slowly.

Configuration Reason

Therefore, multiple radio modules can report it once.


The smaller the value of this parameter, the lower the requirements of

Configuration Rule and


Adjustment Suggestion

power judgment and thus the higher the possibility of power decrease
during power judgment. The larger the value of this parameter, the
higher the requirements of power judgment and thus the lower the
possibility of power decrease during power judgment.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-206
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.2.6.70 Mode of downlink closed loop power control (DlClosePwrCtrlMode)


Full Name

Mode of downlink closed loop power control

Abbreviation

DlClosePwrCtrlMode

3GPP Name

None

3GPP Reference

None
This parameter determines the mode of downlink closed power control.

Description

The modes include rate first and power decrease.

Managed Object

Cell
0: velocity prior mode

Value Range and Step

1: power fall mode

Unit

None

Default Value

Default Value
Configuration Reason

Try to lower the impact on speed when decreasing power.


In the rate first mode, try to lower the impact on the speed of subscribers
when decreasing power. The higher the condition for power control

Configuration Rule and


Adjustment Suggestion

judgment, the smaller the decreased power. In the power decrease


mode, try to decrease the transmit power of the BTS. The looser the
condition for power control judgment, the larger the decreased power.
In this mode, the speed of subscribers may be decreased. Select the
required mode according to requirements.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Set VPC Cell

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-207
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.2.6.71 lowest CS of enabling downlink power control in GPRS (PSPwrCtrlLowCS0)


Full Name

lowest CS of enabling downlink power control in GPRS

Abbreviation

PSPwrCtrlLowCS0

3GPP Name

None

3GPP Reference

None
In the case of power decrease during downlink PS power control, this parameter determines the lowest encoding format allowed for power control

Description

in GPRS mode.

Managed Object

Cell
1: CS1
2: CS2
3: CS3

Value Range and Step

4: CS4

Unit

None

Default Value

Default Value
Configuration Reason

Power must be decreased in good radio environments.


If this parameter is configured to a small value, it indicates that downlink
power control can be implemented with the low encoding format in

Configuration Rule and


Adjustment Suggestion

GPRS mode. In this case, the possibility and scale of power decrease
are high, and the speed loss is high. If this parameter is configured to a
large value, it indicates that downlink power control can be implemented
with the high encoding format in GPRS mode. In this case, the possibility
and scale of power decrease are low, and the speed loss is low.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

iBSCV6.20.710

5-208
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

New

5.2.6.72 lowest MCS of enabling downlink power control in EDGE (PSPwrCtrlLowCS1)


Full Name

lowest MCS of enabling downlink power control in EDGE

Abbreviation

PSPwrCtrlLowCS1

3GPP Name

None

3GPP Reference

None
In the case of power decrease during downlink PS power control, this parameter determines the lowest encoding format allowed for power control

Description

in the EDGE mode.

Managed Object

Cell
1: MCS1
2: MCS2
3: MCS3
4: MCS4
5: MCS5
6: MCS6
7: MCS7
8: MCS8

Value Range and Step

9: MCS9

Unit

None

Default Value

50

Default Value
Configuration Reason

Power must be decreased in good radio environments.


If this parameter is configured to a small value, it indicates that downlink
power control can be implemented with the low encoding format in

Configuration Rule and


Adjustment Suggestion

EDGE mode. In this case, the possibility and scale of power decrease
are high, and the speed loss is high. If this parameter is configured to a
large value, it indicates that downlink power control can be implemented
with the high encoding format in EDGE mode. In this case, the possibility
and scale of power decrease are low, and the speed loss is low.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

5-209
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.73 try to decrease downlink power (TryDecDlPSPwr)


Full Name

try to decrease downlink power

Abbreviation

TryDecDlPSPwr

3GPP Name

None

3GPP Reference

None
In the case of power decrease during downlink PS power control, this
parameter determines whether to apply the power control result directly

Description

to decease power without considering the auto-adaptive judgment result.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Decrease much power in the case of downlink power decease.


It is required to configure this parameter according to the requirements
on site. To decrease much power, select "Yes". To consider both speed
and power decrease, select "No".

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

5-210
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.74 reduced power of dummy usf in good uplink radio condition (DummyUsfPwr0)
Full Name

reduced power of dummy usf in good uplink radio condition

Abbreviation

DummyUsfPwr0

3GPP Name

None

3GPP Reference

None
This parameter determines the deteriorated power of the downlink dummy
block with USF when the downlink power control is enabled and the radio

Description

quality of the uplink TBF is good.

Managed Object

Cell
0: 0db
1: 0.5db
2: 1db
3: 1.5db
4: 2db
5: 2.5db
6: 3db
......
18: 9db
19: 9.5db

Value Range and Step

20: 10db

Unit

db

Default Value

50

Default Value

Power decrease in normal cases is implemented when the uplink signal

Configuration Reason

quality is good.
It is required to configure this parameter according to the requirements

Configuration Rule and

on site. To decrease much power, configure this parameter to a large

Adjustment Suggestion

value. To consider both speed and power decrease, configure this


parameter to a small value.
5-211

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.75 reduced power of dummy usf in general uplink radio condition


(DummyUsfPwr1)
Full Name

reduced power of dummy usf in general uplink radio condition

Abbreviation

DummyUsfPwr1

3GPP Name

None

3GPP Reference

None
This parameter determines the deteriorated power of the downlink dummy
block with USF when the downlink power control is enabled and the radio

Description

quality of the uplink TBF is normal.

Managed Object

Cell
0: 0db
1: 0.5db
2: 1db
3: 1.5db
4: 2db
5: 2.5db
6: 3db
......
18: 9db
19: 9.5db

Value Range and Step

20: 10db

5-212
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

db

Default Value

Default Value

Power decrease in normal cases is implemented when the uplink signal

Configuration Reason

quality is normal.
It is required to configure this parameter according to the requirements

Configuration Rule and


Adjustment Suggestion

on site. To decrease much power, configure this parameter to a large


value. To consider both speed and power decrease, configure this
parameter to a small value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS Power Control
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.2.6.76 reduced power of dummy usf in bad uplink radio condition (DummyUsfPwr2)
Full Name

reduced power of dummy usf in bad uplink radio condition

Abbreviation

DummyUsfPwr2

3GPP Name

None

3GPP Reference

None
This parameter determines the deteriorated power of the downlink dummy
block with USF when the downlink power control is enabled and the radio

Description

quality of the uplink TBF is poor.

Managed Object

Cell

5-213
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0: 0db
1: 0.5db
2: 1db
3: 1.5db
4: 2db
5: 2.5db
6: 3db
......
18: 9db
19: 9.5db
Value Range and Step

20: 10db

Unit

db

Default Value

Default Value

Power decrease in normal cases is implemented when the uplink signal

Configuration Reason

quality is poor.
It is required to configure this parameter according to the requirements

Configuration Rule and

on site. To decrease much power, configure this parameter to a large

Adjustment Suggestion

value. To consider both speed and power decrease, configure this


parameter to a small value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Power


Control->GPRS Power Control

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.3 Handover Control Parameters


There are eight sub-interfaces for handover control parameters.
5-214
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.1 Handover Pretreatment Parameters


5.3.1.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None
This parameter means the site ID. It cannot be modified.

Description

Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover Con-

OMC Access Path


Parameter

Modifying

Version
Parameter
Detail

trol->Handover Pretreatment

None
Modifying
None

5.3.1.2 BTS ID (BtsId)


Full Name

BTS ID
5-215

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell
1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover Con-

OMC Access Path

trol->Handover Pretreatment

5-216
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter

Modifying

Version
Parameter

None
Modifying

Detail

None

5.3.1.3 Handover control ID (HocId)


Full Name

Handover control ID

Abbreviation

HocId

3GPP Name

None

3GPP Reference

None

Description

This parameter means the ID of handover control. It cannot be modified.

Managed Object

Cell

Value Range and Step

1~2

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover Con-

OMC Access Path


Parameter

Modifying

Version
Parameter
Detail

trol->Handover Pretreatment

None
Modifying
None

5-217
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.1.4 Number of zero allowed in AV (ZeroAllowed)


Full Name

Number of zero allowed in AV

Abbreviation

ZeroAllowed

3GPP Name

None

3GPP Reference

None
According to the GSM Specifications, MS can only report the
measurement data of six adjacent cells with the strongest signal
strength. Therefore, the measurement results of adjacent cells recorded
by BSC may be discontinuous, and the measurement data of the missing
cells shall thus be recorded as 0 (that is, less than -110dBm).
To avoid the negative impact of 0 on averaging, suppose occasional 0 is
allowed and is not used in averaging, but excessive occurrences of 0
indicate that the signals of this adjacent cell are too poor.
If the number of zeroes in used for average calculation exceeds Number
of zero allowed in AV, then measurement average equals to sum of
reported values divided by Neighboring cell.
To be specific, during averaging, if the count of 0s in the sampling count
exceeds "ZeroAllowed", these sampling values are hardly reliable, and
the measurement average will be the sum of the reported values divided
by NCellWindow. If the count of 0s in the reported values does not
exceed "ZeroAllowed", these sampling values are much reliable and the
measurement average will be the sum of the reported values divided by
(NCellWindow the count of 0s).

Description

This parameter is used for TCH handover.

Managed Object

Cell
0..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Occasional 0 is acceptable.Excessive occurrences of 0 indicate that the

Configuration Reason

signals of this adjacent cell are too poor.


If the number of 0s allowed is adjusted as too small, the adjacent cell
with good signal maybe missed.

Configuration Rule and

If the number of 0s allowed is adjusted as too large, handover to the

Adjustment Suggestion

adjacent cell with poor signal maybe initiated.


It is recommended to set the value as small as possible, in order to
select the adjacent cell with good signal.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

5-218
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Pretreatment
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.1.5 Uplink power level Sample count (HoUlLevWindow)


Full Name

Uplink power level Sample count

Abbreviation

HoUlLevWindow

3GPP Name

Hreqave

3GPP Reference

3GPP TS 45.008
In the GSM system, BSC makes handover decision according to the
measurement data. To avoid the negative impact of burst measurement
values resulting from complicated radio transmission, BSC, when
making handover decision, no longer uses the original measurement
data but uses a series of average values of the measurement data.
This parameter is the window size (number of sample values) used to
calculate the average value of uplink signal intensity.

Description

This parameter is used for TCH handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Number of samples should be enough for ensuring the preciseness of


handover decision, and for initiating handover as early as possible when
the signal is poor during communication.

5-219
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If the value is set too small and samples of handover decision are few,
Configuration Rule and

the handover decision is incorrect.

Adjustment Suggestion

If the value is set too large, it takes a long time to make handover
decisions and call drop occurs easily caused by handover delays.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Pretreatment
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.1.6 Uplink level Weight (HoUlLevWeight)


Full Name

Uplink level Weight

Abbreviation

HoUlLevWeight

3GPP Name

None

3GPP Reference

None
According to the GSM Specifications, discontinuous transmission (DTX)
refers to the process in which the system does not transmit signals in the
voice intermittent period during the subscriber communication process.
In the DTX mode, the measurement data reported to BSC fall into two
types. One is the average of the measurement results of all timeslots in a
measurement period in the non-DTX mode, and the other is the average
of the measurement results of some special timeslots in a measurement
period in the DTX mode. BSC needs to optionally select one type of
measurement data and use the data to calculate the average value.
The first type of measurement data is the average of the measurement
results of all timeslots, and it is accurate. But the second type of

Description

measurement data is the average of the measurement results of some

5-220
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

timeslots, and it is less accurate. Therefore, BSC, when averaging


the measurement values, uses different weights for the two types of
measurement data.
This parameter HoDlLevWeight determines the weight for the first
type of measurement data when averaging downlink signal strength
for handover. Weight for the second type of measurement data is set
to 1 by default.
This parameter is used for TCH handover.
Managed Object

Cell
1..3

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

In the non-DTX mode, the measurement data is accurate, so the weight

Configuration Reason

is relatively high.

Configuration Rule and


Adjustment Suggestion

Generally, it is recommended not to modify the weight.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.1.7 Downlink power level Sample count (HoDlLevWindow)


Full Name

Downlink power level Sample count

Abbreviation

HoDlLevWindow
5-221

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

Hreqave

3GPP Reference

3GPP TS 45.008
In the GSM system, BSC makes handover decision according to the
measurement data. To avoid the negative impact of burst measurement
values resulting from complicated radio transmission, BSC, when
making handover decision, no longer uses the original measurement
data but uses a series of average values of the measurement data.
The parameter of handover downlink intensity average window
"HoDlLevWindow" is the size of the window used to calculate the
average value of downlink signal strength. This size is the number of
samples used in averaging.

Description

This parameter is used for TCH handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Number of samples should be enough for ensuring the preciseness of


handover decision, and for initiating handover as early as possible when
the signal is poor during communication.
If the value is set too small and samples of handover decision are few,

Configuration Rule and


Adjustment Suggestion

the handover decision is incorrect.


If the value is set too large, it takes a long time to make handover
decisions, which is likely to result in call drops caused by handover
delays.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Pretreatment
Parameter Modifying
Version

None
5-222

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.3.1.8 Downlink level Weight (HoDlLevWeight)


Full Name

Downlink level Weight

Abbreviation

HoDlLevWeight

3GPP Name

None

3GPP Reference

None
According to the GSM Specifications, discontinuous transmission (DTX)
refers to the process in which the system does not transmit signals in the
voice intermittent period during the subscriber communication process.
In the DTX mode, the measurement data reported to BSC fall into two
types. One is the average of the measurement results of all timeslots in a
measurement period in the non-DTX mode, and the other is the average
of the measurement results of some special timeslots in a measurement
period in the DTX mode. BSC needs to optionally select one type of
measurement data and use the data to calculate the average value.
The first type of measurement data is the average of the measurement
results of all timeslots, and it is accurate. But the second type of
measurement data is the average of the measurement results of some
timeslots, and it is less accurate. Therefore, BSC, when averaging
the measurement values, uses different weights for the two types of
measurement data.
This parameter HoDlLevWeight determines the weight for the first
type of measurement data when averaging downlink signal strength
for handover. Weight for the second type of measurement data is set
to 1 by default.

Description

This parameter is used for TCH handover.

Managed Object

Cell
1..3

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

In the non-DTX mdoe, the measurement data is accurate, so the weight

Configuration Reason

is relatively high.

Configuration Rule and


Adjustment Suggestion

Generally, it is recommended not to modify the weight.

Change Mode

Offline

5-223
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Pretreatment
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.1.9 Uplink quality Sample count (HoUlQualWindow)


Full Name

Uplink quality Sample count

Abbreviation

HoUlQualWindow

3GPP Name

Hreqave

3GPP Reference

3GPP TS 45.008
In the GSM system, BSC makes handover decision according to the
measurement data. To avoid the negative impact of burst measurement
values resulting from complicated radio transmission, BSC, when
making handover decision, no longer uses the original measurement
data but uses a series of average values of the measurement data.
This parameter represents the window size (number of sample values)
used to calculate average value of uplink signal quality.

Description

This parameter is used for TCH handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Number of samples should be enough for ensuring the preciseness of


handover decision, and for initiating handover as early as possible when
the signal is poor during communication.
5-224

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

If the value is set too small and samples of handover decision are few,
Configuration Rule and

the handover decision is incorrect.

Adjustment Suggestion

If the value is set too large, it takes a long time to make handover
decisions and call drop occurs easily caused by handover delays.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Pretreatment
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.1.10 Uplink quality Weight (HoUlQualWeight)


Full Name

Uplink quality Weight

Abbreviation

HoUlQualWeight

3GPP Name

None

3GPP Reference

None
According to the GSM Specifications, discontinuous transmission (DTX)
refers to the process in which the system does not transmit signals in the
voice intermittent period during the subscriber communication process.
In the DTX mode, the measurement data reported to BSC fall into two
types. One is the average of the measurement results of all timeslots in a
measurement period in the non-DTX mode, and the other is the average
of the measurement results of some special timeslots in a measurement
period in the DTX mode. BSC needs to optionally select one type of
measurement data and use the data to calculate the average value.
The first type of measurement data is the average of the measurement
results of all timeslots, and it is accurate. But the second type of

Description

measurement data is the average of the measurement results of some

5-225
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

timeslots, and it is less accurate. Therefore, BSC, when averaging


the measurement values, uses different weights for the two types of
measurement data.
Parameter "HoUlQualWeight" determines the weight for the first type of
measurement data when averaging uplink signal quality for handover.
Weight for the second type of measurement data is set to 1 by default.
This parameter is used for TCH handover.
Managed Object

Cell
1..3

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

In the non-DTX mode, the measurement data is accurate, so the weight

Configuration Reason

is relatively high.

Configuration Rule and


Adjustment Suggestion

Generally, it is recommended not to modify the weight.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.1.11 Downlink quality Sample count (HoDlQualWindow)


Full Name

Downlink quality Sample count

Abbreviation

HoDlQualWindow

3GPP Name

Hreqave
5-226

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Reference

3GPP TS 45.008
In the GSM system, BSC makes handover decision according to the
measurement data. To avoid the negative impact of burst measurement
values resulting from complicated radio transmission, BSC, when
making handover decision, no longer uses the original measurement
data but uses a series of average values of the measurement data.
The parameter of handover downlink quality average window
"HoDlQualWindow" is the size of the window used to calculate the
average value of downlink signal quality. This size is the number of
samples used in averaging.

Description

This parameter is used for TCH handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Number of samples should be enough for ensuring the preciseness of


handover decision, and for initiating handover as early as possible when
the signal is poor during communication.
If the value is set too small and samples of handover decision are few,

Configuration Rule and


Adjustment Suggestion

the handover decision is incorrect.


If the value is set too large, it takes a long time to make handover
decisions, which is likely to result in call drops caused by handover
delays.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Pretreatment
Parameter Modifying
Version

None

5-227
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.3.1.12 Downlink quality Weight (HoDlQualWeight)


Full Name

Downlink quality Weight

Abbreviation

HoDlQualWeight

3GPP Name

None

3GPP Reference

None
According to the GSM Specifications, discontinuous transmission (DTX)
refers to the process in which the system does not transmit signals in the
voice intermittent period during the subscriber communication process.
In the DTX mode, the measurement data reported to BSC fall into two
types. One is the average of the measurement results of all timeslots in a
measurement period in the non-DTX mode, and the other is the average
of the measurement results of some special timeslots in a measurement
period in the DTX mode. BSC needs to optionally select one type of
measurement data and use the data to calculate the average value.
The first type of measurement data is the average of the measurement
results of all timeslots, and it is accurate. But the second type of
measurement data is the average of the measurement results of some
timeslots, and it is less accurate. Therefore, BSC, when averaging
the measurement values, uses different weights for the two types of
measurement data.
Parameter HoDlQualWeight determines the weight for the first type of
measurement data when averaging downlink signal quality for handover.
Weight for the second type of measurement data is set to 1 by default.

Description

This parameter is used for TCH handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

In the non-DTX mode, the measurement data is accurate, so the weight

Configuration Reason

is relatively high.

Configuration Rule and


Adjustment Suggestion

Generally, it is recommended not to modify the weight.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

5-228
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Pretreatment
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.1.13 Distance (DistanceWindow)


Full Name

Distance

Abbreviation

DistanceWindow

3GPP Name

Hreqave

3GPP Reference

3GPP TS 45.008
In the GSM system, BSC makes handover decision according to the
measurement data. To avoid the negative impact of burst measurement
values resulting from complicated radio transmission, BSC, when
making handover decision, no longer uses the original measurement
data but uses a series of average values of the measurement data.
The parameter of sampling count of distance "DistanceWindow" is the
size of the window used to calculate the average value of the distance
from MS to BTS (actually the Time Advance, TA). This size is the number
of samples used in averaging.

Description

This parameter is used for TCH handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

5-229
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

Number of samples should be enough for ensuring the preciseness of


handover decision, and initiating hangover as early as possible when the
signal is poor during communication.
If the value is set too small and samples of handover decision are too

Configuration Rule and


Adjustment Suggestion

few, the handover decision is incorrect.


If the value is set too large, it takes a long time to make handover
decisions, which is likely to result in call drops caused by handover
delays.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.1.14 Neighboring cell (NCellWindow)


Full Name

Neighboring cell

Abbreviation

NCellWindow

3GPP Name

Hreqave

3GPP Reference

3GPP TS 45.008

5-230
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

In the GSM system, BSC makes handover decision according to the


measurement data. To avoid the negative impact of burst measurement
values resulting from complicated radio transmission, BSC, when
making handover decision, no longer uses the original measurement
data but uses a series of average values of the measurement data.
The parameter of adjacent cell average window "NcellWindow" is the
size of the window used to calculate the average value of adjacent cell
signal strength. This size is the number of samples used in averaging.
This parameter is used for TCH handover and only for non-emergency
Description

handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Number of samples should be enough for ensuring the preciseness of


handover decision, and for initiating handover as early as possible when
the signal is poor during communication.
If the value is set too small and samples of handover decision are few,

Configuration Rule and


Adjustment Suggestion

the handover decision is incorrect.


If the value is set too large, it takes a long time to make handover
decisions, which is likely to result in call drops caused by handover
delays.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-231
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.1.15 Neighbour cell for emergency handover (NCELLWINDOWEMERG)


Full Name

Neighbour cell for emergency handover

Abbreviation

NCELLWINDOWEMERG

3GPP Name

Hreqave

3GPP Reference

3GPP TS 45.008
In the GSM system, BSC makes handover decision according to the
measurement data. To avoid the negative impact of burst measurement
values resulting from complicated radio transmission, BSC, when
making handover decision, no longer uses the original measurement
data but uses a series of average values of the measurement data.
This parameter indicates the size of the window used to calculate
the average value of adjacent cell signal strength during emergency
handover. This size is the number of samples used in averaging.
The emergency handover includes quality handover, level handover,
intra-cell interference handover, uplink signal rapid attenuation handover,
downlink quality rapid drop handover, and handover from the second

Description

sub cell to the first sub cell.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Number of samples should be enough for ensuring the preciseness of


handover decision, and for initiating handover as early as possible to
avoid call drop when the signal is poor during communication.
If the value is set too small and samples of handover decision are few,

Configuration Rule and

the handover decision is incorrect.

Adjustment Suggestion

If the value is set too large, it takes a long time to make handover
decisions and call drop occurs easily caused by handover delays.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-232
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2 Handover Level Parameters


5.3.2.1 Uplink receive level Value N (HoUlLevN)
Full Name

Uplink receive level Value N

Abbreviation

HoUlLevN

3GPP Name

None

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter indicates the value N of TCHuplink level handover.
According to the GSM specifications, handover decisions depend upon
the received average value.
Uplink receiving intensity is one of the causes for handover. The decision
process is as follows: For the latest N average values of uplink signal
strength, if P of the N values fall below relevant threshold value, perform
handover to improve the uplink signal strength.
Parameter "HoUlLevThs" defines the related threshold, parameter
"HoUlLevN" defines the related N value, and parameter "HoUlLevP"
defines the related P value.
Usually, the value of "HoUlLevThs" shall be less than the threshold for
uplink power control (increase). That is, perform power control first. If

Description

power control does not work, perform handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value as this, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.

Configuration Rule and


Adjustment Suggestion

The larger the value is, the higher is the accuracy of handover decision,
the lower is the realtime; The smaller the value is, the lower is the
accuracy of handover decision, the higher is the realtime.
5-233

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoUlLevP

Relationship

HoUlLevP<=HoUlLevN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Level
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.2 Uplink receive level Value P (HoUlLevP)


Full Name

Uplink receive level Value P

Abbreviation

HoUlLevP

3GPP Name

None

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter indicates the value P of TCHuplink level handover.
According to the GSM specifications, handover decisions depend upon
the received average value.
Uplink receiving intensity is one of the causes for handover. The decision
process is as follows: For the latest N average values of uplink signal
strength, if P of the N values fall below relevant threshold value, perform
handover to improve the uplink signal strength.
Parameter "HoUlLevThs" defines the related threshold, parameter
"HoUlLevN" defines the related N value, and parameter "HoUlLevP"
defines the related P value.
Usually, the value of "HoUlLevThs" shall be less than the threshold for
uplink power control (increase). That is, perform power control first. If

Description

power control does not work, perform handover.

Managed Object

Cell

5-234
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

1..20
Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value as this, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.

Configuration Rule and

smaller the value is, the easier the handover is.If the value is too large,

Adjustment Suggestion

quantity of call drops rises easily. If the value is too small, number of

The larger the value is, it is more difficult to perform handover. The

unnecessary handovers may increase.


Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoUlLevN

Relationship

HoUlLevP<=HoUlLevN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.3 Uplink receive level Threshold (HoUlLevThs)


Full Name

Uplink receive level Threshold

Abbreviation

HoUlLevThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008 V5.22.0

5-235
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the threshold of TCHuplink level handover.


According to the GSM specifications, handover decisions depend upon
the received average value.
Uplink receiving intensity is one of the causes for handover. The decision
process is as follows: For the latest N average values of uplink signal
strength, if P of the N values fall below relevant threshold value, perform
handover to improve the uplink signal strength.
Parameter "HoUlLevThs" defines the related threshold, parameter
"HoUlLevN" defines the related N value, and parameter "HoUlLevP"
defines the related P value.
Usually, the value of "HoUlLevThs" shall be less than the threshold for
uplink power control (increase). That is, perform power control first. If
Description

power control does not work, perform handover.

Managed Object

Cell
0..63;
0: < -110 dBm;
1: (-110..-109)dBm;
......
62: (-49..-48)dBm;
63: < -48 dBm;

Value Range and Step

Step: 1

Unit

None

Default Value

15

Default Value

Usually, -95 dbm is considered as the demarcation point between the

Configuration Reason

good uplink level and poor uplink level.


The value the larger is, the handover is more unlikely to occur, and vice

Configuration Rule and

versa the handover is easier to occur.If the value is too large, quantity

Adjustment Suggestion

of call drops may rise. If the value is too small, excessive handovers
may occur.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]PcUlInclLevThs
Usually the value of "HoUlLevThs" should be less than the threshold for

Relationship

uplink power control (increase). That is, perform power control first. If
power control does not work, perform handover.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-236
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.4 Downlink receive level Value N (HoDlLevN)


Full Name

Downlink receive level Value N

Abbreviation

HoDlLevN

3GPP Name

None

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter indicates the value N of TCHdownlink level handover.
According to the GSM specifications, handover decisions depend upon
the received average value.Downlink receiving intensity is one of the
causes for handover. The decision process is as follows: For the latest
N average values of downlink signal strength, if P of the N values
fall below relevant threshold value, perform handover to improve the
downlink signal strength.
Parameter "HoDlLevThs" defines the related threshold, parameter
"HoDlLevN" defines the related N value, and parameter "HoDlLevP"
defines the related P value.
Usually the value of "HoDlLevThs" shall be less than the threshold for
downlink power control (increase). That is, perform power control first. If
power control does not work, perform handover. This parameter can be
set to 15 by default (i.e. -96 dBm..-95 dBm), which is 3 dB larger than

Description

the minimum access level value (RxLevAccessMin) of the cell.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value as this, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.

Configuration Rule and


Adjustment Suggestion

The larger the value is, the more is the accuracy of handover decision,
the lower is the realtime; The smaller the value is, the less is the
accuracy of handover decision, the higher is the realtime.

5-237
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoDlLevP

Relationship

HoDlLevP<=HoDlLevN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Level
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.5 Downlink receive level Value P (HoDlLevP)


Full Name

Downlink receive level Value P

Abbreviation

HoDlLevP

3GPP Name

None

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter indicates the value P of TCHdownlink level handover.
According to the GSM specifications, handover decisions depend upon
the received average value.Downlink receiving intensity is one of the
causes for handover. The decision process is as follows: For the latest
N average values of downlink signal strength, if P of the N values
fall below relevant threshold value, perform handover to improve the
downlink signal strength.
Parameter "HoDlLevThs" defines the related threshold, parameter
"HoDlLevN" defines the related N value, and parameter "HoDlLevP"
defines the related P value.
Usually the value of "HoDlLevThs" shall be less than the threshold for
downlink power control (increase). That is, perform power control first. If
power control does not work, perform handover. This parameter can be
set to 15 by default (i.e. -96 dBm..-95 dBm), which is 3 dB larger than

Description

the minimum access level value (RxLevAccessMin) of the cell.

Managed Object

Cell
5-238

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

1..20
Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value as this, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.

Configuration Rule and

smaller the value is, the easier the handover is.If the value is too large,

Adjustment Suggestion

quantity of call drops rise easily. If the value is too small, number of

The larger the value is, it is more difficult to perform handover. The

unnecessary handovers may increase.


Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoDlLevN

Relationship

HoDlLevP<=HoDlLevN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.6 Downlink receive level Threshold (HoDlLevThs)


Full Name

Downlink receive level Threshold

Abbreviation

HoDlLevThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008 V5.22.0

5-239
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the threshold of TCHdownlink level handover.


According to the GSM specifications, handover decisions depend upon
the received average value.Downlink receiving intensity is one of the
causes for handover. The decision process is as follows: For the latest
N average values of downlink signal strength, if P of the N values
fall below relevant threshold value, perform handover to improve the
downlink signal strength.
Parameter "HoDlLevThs" defines the related threshold, parameter
"HoDlLevN" defines the related N value, and parameter "HoDlLevP"
defines the related P value.
Usually the value of "HoDlLevThs" shall be less than the threshold for
downlink power control (increase). That is, perform power control first. If
power control does not work, perform handover. This parameter can be
set to 15 by default (i.e. -96 dBm..-95 dBm), which is 3 dB larger than
Description

the minimum access level value (RxLevAccessMin) of the cell.

Managed Object

Cell
0..63;
0: < -110 dBm;
1: (-110..-109)dBm;
......
62: (-49..-48)dBm;
63: < -48 dBm;

Value Range and Step

Step: 1

Unit

None

Default Value

15

Default Value

Usually, -95 dbm is considered as the demarcation point between the

Configuration Reason

good uplink level and poor uplink level.


The value the larger is, the handover is more unlikely to occur, and vice

Configuration Rule and

versa the handover is easier to occur.If the value is too large, quantity

Adjustment Suggestion

of call drops may rise. If the value is too small, excessive handovers
may occur.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]PcDlInclLevThs
Usually the value of "HoDlLevThs" shall be less than the threshold for

Relationship

downlink power control (increase). That is, perform power control first. If
power control does not work, perform handover.

Related Interfaces

None

Impact on Equipment

5-240
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.7 Uplink receive quality Value N (HoUlQualN)


Full Name

Uplink receive quality Value N

Abbreviation

HoUlQualN

3GPP Name

None

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter indicates the value N of TCHuplink quality.
According to the GSM specifications, handover decisions depend upon
the received average value.Uplink receive quality is one of the causes for
handover. The decision process is as follows: For the latest N average
values of uplink signal quality, if P of the N values rise above relevant
threshold value, perform handover to improve the uplink signal quality.
Parameter "HoUlQualThs" defines the related threshold, parameter
"HoUlQualN" defines the related N value, and parameter "HoUlQualP"
defines the related P value.
Usually the value of "HoUlQualThs" shall be greater than the threshold
for uplink power control (increase). That is, perform power control first. If

Description

power control does not work, perform handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value as this, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.

Configuration Rule and


Adjustment Suggestion

The larger the value is, the higher is the accuracy of handover decision,
the lower is the realtime; The smaller the value is, the lower is the
accuracy of handover decision, the higher is the realtime.

5-241
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoUlQualP

Relationship

HoUlQualP<=HoUlQualN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Level
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.8 Uplink receive quality Value P (HoUlQualP)


Full Name

Uplink receive quality Value P

Abbreviation

HoUlQualP

3GPP Name

None

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter indicates the value P of TCHuplink quality.
According to the GSM specifications, handover decisions depend upon
the received average value.Uplink receive quality is one of the causes for
handover. The decision process is as follows: For the latest N average
values of uplink signal quality, if P of the N values rise above relevant
threshold value, perform handover to improve the uplink signal quality.
Parameter "HoUlQualThs" defines the related threshold, parameter
"HoUlQualN" defines the related N value, and parameter "HoUlQualP"
defines the related P value.
Usually the value of "HoUlQualThs" shall be greater than the threshold
for uplink power control (increase). That is, perform power control first. If

Description

power control does not work, perform handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

5-242
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

None

Default Value

Default Value

It is recommended to set the default value as this, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.


The larger the value is, it is more difficult to perform handover. The

Configuration Rule and

smaller the value is, the easier the handover is.If the value is too large,

Adjustment Suggestion

quantity of call drops rises easily. If the value is too small, number of
unnecessary handovers may increase.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoUlQualN

Relationship

HoUlQualP<=HoUlQualN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.9 Uplink receive quality Threshold (HoUlQualThs)


Full Name

Uplink receive quality Threshold

Abbreviation

HoUlQualThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008 V5.22.0

5-243
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the threshold of TCHhandover uplink quality.


According to the GSM specifications, handover decisions depend upon
the received average value.Uplink receive quality is one of the causes for
handover. The decision process is as follows: For the latest N average
values of uplink signal quality, if P of the N values rise above relevant
threshold value, perform handover to improve the uplink signal quality.
Parameter "HoUlQualThs" defines the related threshold, parameter
"HoUlQualN" defines the related N value, and parameter "HoUlQualP"
defines the related P value.
Usually the value of "HoUlQualThs" shall be greater than the threshold
for uplink power control (increase). That is, perform power control first. If
Description

power control does not work, perform handover.

Managed Object

Cell
0..70

Value Range and Step

Step: 1

Unit

None

Default Value

49

Default Value
Configuration Reason

Generally, the quality is considered as poor when its level is above 49.
The value the larger is, the handover is more unlikely to occur, and vice

Configuration Rule and

versa the handover is easier to occur.If the value is too large, quantity

Adjustment Suggestion

of call drops may rise. If the value is too small, excessive handovers
may occur.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-244
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.2.10 Downlink receive quality Value N (HoDlQualN)


Full Name

Downlink receive quality Value N

Abbreviation

HoDlQualN

3GPP Name

None

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter indicates the value N of TCHdownlink quality handover.
According to the GSM specifications, handover decisions depend
upon the received average value.Downlink receive quality is one of
the causes for handover. The decision process is as follows: For the
latest N average values of downlink signal quality, if P of the N values
rise above relevant threshold value, perform handover to improve the
downlink signal quality.
Parameter "HoDlQualThs" defines the related threshold, parameter
"HoDlQualN" defines the related N value, and parameter "HoDlQualP"
defines the related P value.
In general, the Downlink receive quality threshold shall be larger than
downlink power control (increase) threshold, i.e. perform power control

Description

first, and then perform handover if power control fails.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value as this, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.

Configuration Rule and


Adjustment Suggestion

The larger the value is, the higher is the accuracy of handover decision,
the lower is the realtime; The smaller the value is, the lower is the
accuracy of handover decision, the higher is the realtime.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoDlQualP

Relationship

HoDlQualP<=HoDlQualN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-245
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.11 Downlink receive quality Value P (HoDlQualP)


Full Name

Downlink receive quality Value P

Abbreviation

HoDlQualP

3GPP Name

None

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter indicates the value P of TCHdownlink quality handover.
According to the GSM specifications, handover decisions depend
upon the received average value.Downlink receive quality is one of
the causes for handover. The decision process is as follows: For the
latest N average values of downlink signal quality, if P of the N values
rise above relevant threshold value, perform handover to improve the
downlink signal quality.
Parameter "HoDlQualThs" defines the related threshold, parameter
"HoDlQualN" defines the related N value, and parameter "HoDlQualP"
defines the related P value.
In general, the downlink receive quality threshold shall be larger than
downlink power control (increase) threshold, i.e. perform power control

Description

first, and then perform handover if power control fails.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value as this, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.


The larger the value is, it is more difficult to perform handover. The

Configuration Rule and

smaller the value is, the easier the handover is.If the value is too large,

Adjustment Suggestion

quantity of call drops rises easily. If the value is too small, number of
unnecessary handovers may increase.

Change Mode

Offline

5-246
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoDlQualN

Relationship

HoDlQualP<=HoDlQualN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Level
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.12 Downlink receive quality Threshold (HoDlQualThs)


Full Name

Downlink receive quality Threshold

Abbreviation

HoDlQualThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter indicates the threshold of TCHdownlink quality handover.
According to the GSM specifications, handover decisions depend
upon the received average value.Downlink receive quality is one of
the causes for handover. The decision process is as follows: For the
latest N average values of downlink signal quality, if P of the N values
rise above relevant threshold value, perform handover to improve the
downlink signal quality.
Parameter "HoDlQualThs" defines the related threshold, parameter
"HoDlQualN" defines the related N value, and parameter "HoDlQualP"
defines the related P value.
In general, the downlink receive quality threshold shall be larger than
downlink power control (increase) threshold, i.e. perform power control

Description

first, and then perform handover if power control fails.

Managed Object

Cell
0..70

Value Range and Step

Step: 1

5-247
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

49

Default Value

Generally, downlink quality is considered as poor when its level is above

Configuration Reason

19.
The value the larger is, the handover is more unlikely to occur, and vice

Configuration Rule and

versa the handover is easier to occur.If the value is too large, quantity

Adjustment Suggestion

of call drops may rise. If the value is too small, excessive handovers
may occur.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.13 Uplink receive level of intra-ho Value N (IntraHoUlLevN)


Full Name

Uplink receive level of intra-ho Value N

Abbreviation

IntraHoUlLevN

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008

5-248
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

According to the GSM specifications, handover decisions depend upon


the received average value. The uplink co-frequency interference is one
of the causes for handover. The decision process is as follows: If the
handover condition of uplink quality is met and P out of the N values (the
latest N average values of uplink signal strength) rise above relevant
threshold value, perform handover. The handover is due to strong uplink
co-frequency interference.
Parameter "IntraHoUlLevThs" defines the related threshold, parameter
"IntraHoUlLevN" defines the related N value, and parameter
"IntraHoUlLevP" defines the related P value.If this handover condition is
met, an internal handover is usually performed in the cell.
Usually the value of "IntraHoUlLevThs" shall be more than the threshold
for uplink power control (decrease).
Description

This parameter is used for TCH handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value to 3, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.


If the value is set too small and samples of handover decision are few,

Configuration Rule and

the handover decision is incorrect.

Adjustment Suggestion

If the value is set too large, it takes a long time to make handover
decisions and call drop occurs easily caused by handover delays.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

5-249
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.3.2.14 Uplink receive level of intra-ho Value P (IntraHoUlLevP)


Full Name

Uplink receive level of intra-ho Value P

Abbreviation

IntraHoUlLevP

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008
According to the GSM specifications, handover decisions depend upon
the received average value. The uplink co-frequency interference is one
of the causes for handover. The decision process is as follows: If the
handover condition of uplink quality is met and P out of the N values (the
latest N average values of uplink signal strength) rise above relevant
threshold value, perform handover. The handover is due to strong uplink
co-frequency interference.
Parameter "IntraHoUlLevThs" defines the related threshold, parameter
"IntraHoUlLevN" defines the related N value, and parameter
"IntraHoUlLevP" defines the related P value.If this handover condition is
met, an internal handover is usually performed in the cell.
Usually the value of "IntraHoUlLevThs" shall be more than the threshold
for uplink power control (decrease).

Description

This parameter is used for TCH handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value to 2, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.


If the value is too small, it is very easy to satisfy the condition of

Configuration Rule and

handover decision, handover is too frequent.

Adjustment Suggestion

If the value is too large, it is very difficult to satisfy the condition of


handover decision.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

5-250
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.15 Downlink receive level of intra-ho Value N (IntraHoDlLevN)


Full Name

Downlink receive level of intra-ho Value N

Abbreviation

IntraHoDlLevN

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008
According to the GSM specifications, handover decisions depend upon
the received average value.
The downlink co-frequency interference is one of the causes for
handover. The decision process is as follows: If the downlink quality
condition for handover is met and P out of N recent downlink signal
strength averages are more than the related threshold, handover shall
be performed, because the downlink co-frequency interference is very
strong.
Parameter "IntraHoDlLevThs" defines the related threshold, parameter
"IntraHoDlLevN" defines the related N value, and parameter
"IntraHoDlLevP" defines the related P value.If this handover condition is
met, an internal handover is usually performed in the cell.
Usually the value of "IntraHoDlLevThs" shall be less than (or equal to)
the threshold for downlink power control (decrease).

Description

This parameter is used for TCH handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

5-251
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

It is recommended to set the default value to 3, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.


If the value is set too small and samples of handover decision are few,

Configuration Rule and

the handover decision is incorrect.

Adjustment Suggestion

If the value is set too large, it takes a long time to make handover
decisions and call drop occurs easily caused by handover delays.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.16 Downlink receive level of intra-ho Value P (IntraHoDlLevP)


Full Name

Downlink receive level of intra-ho Value P

Abbreviation

IntraHoDlLevP

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008
According to the GSM specifications, handover decisions depend upon
the received average value.
The downlink co-frequency interference is one of the causes for
handover. The decision process is as follows: If the downlink quality
condition for handover is met and P out of N recent downlink signal
strength averages are more than the related threshold, handover shall
be performed, because the downlink co-frequency interference is very
strong.
Parameter "IntraHoDlLevThs" defines the related threshold, parameter

Description

"IntraHoDlLevN" defines the related N value, and parameter


5-252

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

"IntraHoDlLevP" defines the related P value.If this handover condition is


met, an internal handover is usually performed in the cell.
Usually the value of "IntraHoDlLevThs" shall be less than (or equal to)
the threshold for downlink power control (decrease).
This parameter is used for TCH handover.
Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value to 2, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.


If the value is too small, it is very easy to satisfy the condition of

Configuration Rule and


Adjustment Suggestion

handover decision, handover is too frequent.


If the value is too large, it is very difficult to satisfy the condition of
handover decision.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.17 Good CI/Value N/Value p (GoodCiThs / GoodCiN / GoodCiP)


Full Name

Good CI/Value N/Value p

Abbreviation

GoodCiThs / GoodCiN / GoodCiP

3GPP Name

None
5-253

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

None
If the system has adopted concentric technology, handover decisions
are dependent upon a series of average values obtained.
Good C/I of the current special layer frequency is one of the causes for
concentric handover. The decision process is as follows: If the paging is
on common layer TRX frequency and P of the latest N C/I values raise
above the good C/I threshold, perform handover from common layer
TRX frequency to special layer TRX frequency.
Parameter "GoodCiThs" defines the related threshold, parameter
"GoodCiN" defines the related N value, and parameter "GoodCiP"

Description

defines the related P value.

Managed Object

Cell
Threshold: 0..25 Step: 1;
0: -127 dB
1: -126 dB
...
255: 128 dB
N value: 1..20 Step: 1

Value Range and Step

P value: 1..20 Step: 1

Unit

None

Default Value

[133, 3, 2]

Default Value
Configuration Reason

The default value is the experience value of common radio network.


This parameter is valid till the system is configured as concentric

Configuration Rule and

structure and employs the handover algorithm based on C/I. The smaller

Adjustment Suggestion

the value is, the easier it is to satisfy handover requirements. Otherwise,


it is more difficult to satisfy the handover requirements.

Change Mode

Offline

Related features

ZGO-05-02-009 Concentric Circle Technology

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

5-254
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.18 Bad CI/Value N/Value p (BadCiThs / BadCiN / BadCiP)


Full Name

Bad CI/Value N/Value p

Abbreviation

BadCiThs / BadCiN / BadCiP

3GPP Name

None

3GPP Reference

None
If the system has adopted concentric technology, handover decisions
are dependent upon a series of average values obtained.
Bad C/I of the current special layer frequency is one of the causes for
concentric handover. The decision process is as follows: If the paging
is on special layer TRX frequency and P of the latest N C/I values fall
below the bad C/I threshold, then perform handover from special layer
TRX frequency to common layer TRX frequency.
Parameter "BadCiThs" defines the related threshold, parameter
"BadCiN" defines the related N value, and parameter "BadCiP" defines

Description

the related P value.

Managed Object

Cell
Threshold: 0..25 Step: 1;
0: -127 dB
1: -126 dB
...
255: 128 dB
N value: 1..20 Step: 1

Value Range and Step

P value: 1..20 Step: 1

Unit

None

Default Value

[130, 3, 2]

Default Value
Configuration Reason

The default value is the experience value of general radio network.


This parameter is valid till the system is configured as concentric

Configuration Rule and

structure and employs the handover algorithm based on C/I. The smaller

Adjustment Suggestion

the value is, the easier it is to satisfy handover requirements. Otherwise,


it is more difficult to satisfy the handover requirements.

Change Mode

Offline

Related features

ZGO-05-02-009 Concentric Circle Technology

5-255
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Level
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.19 Rapid handover Threshold (RapidHoThs)


Full Name

Rapid handover Threshold

Abbreviation

RapidHoThs

3GPP Name

None

3GPP Reference

None
During fast fading handover, some parameters shall be used. If the
measured signal intensity of a call is less than rapid handover threshold,
then it triggers handover of existing cell to most probable candidate cell.
"RapidHoThs" may be set as 15 (that is, -96 dBm .. -95 dBm) by default,

Description

the same as the level threshold of ordinary handover.

Managed Object

Cell
0..63;
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
......
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

10

Default Value

According to the on-site configuration experience, if the default value is

Configuration Reason

[10.2], the speed and timeliness of handover is reasonable.

5-256
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Rapid handover is characterized by fast speed, so the handover


Configuration Rule and

threshold should not be too large. MS will move to the area with high

Adjustment Suggestion

cell level soon. N value cannot be too large, otherwise the timeliness of
handover judgement will be influenced.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Level
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.20 Rapid handover Value N (RapidHoN)


Full Name

Rapid handover Value N

Abbreviation

RapidHoN

3GPP Name

None

3GPP Reference

None
During fast fading handover, some parameters shall be used.
RapidHoN counter defines the minimum times for which the measured

Description

signal intensity of a call is less than the threshold.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

According to the on-site configuration experience, if the default value is

Configuration Reason

[10.2], the speed and timeliness of handover is reasonable.

5-257
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Rapid handover is characterized by fast speed, so the handover


Configuration Rule and

threshold should not be too large. MS will move to the area with high

Adjustment Suggestion

cell level soon. N value cannot be too large, otherwise the timeliness of
handover judgement will be influenced.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Level
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.21 Distance handover Value N (DistanceN)


Full Name

Distance handover Value N

Abbreviation

DistanceN

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008
According to the GSM specifications, TCH handover decisions depend
upon the received average value.
The distance from MS to BTS is also one of the causes for handover.
The decision process is as follows: For the latest N average values of
TA (distance), if P of the N values rises above relevant threshold value,
perform handover. The handover is due to MS being out of the cell

Description

service range.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None
5-258

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

Default Value

It is recommended to set the default value to 3, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.


If the value is set too small and samples of handover decision are few,

Configuration Rule and


Adjustment Suggestion

the handover decision is incorrect.


If the value is set too large, it takes a long time to make handover
decisions, which is likely to result in call drops caused by handover
delays.

Change Mode

Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

[Cell]DistanceP

Relationship

This parameter value should be larger than or equal to DistanceP.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Level
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.22 Distance handover Value P (DistanceP)


Full Name

Distance handover Value P

Abbreviation

DistanceP

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008

5-259
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

According to the GSM specifications, TCH handover decisions depend


upon the received average value.
The distance from MS to BTS is also one of the causes for handover.
The decision process is as follows: For the latest N average values of
TA (distance), if P of the N values rises above relevant threshold value,
perform handover. The handover is due to MS being out of the cell
Description

service range.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value to 2, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.


If the value is too small, it is very easy to satisfy the condition of

Configuration Rule and

handover decision, handover is too frequent.

Adjustment Suggestion

If the value is too large, it is very difficult to satisfy the condition of


handover decision.

Change Mode

Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

[Cell]DistanceN

Relationship

This parameter value should be smaller than or equal to DistanceN.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-260
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.2.23 PBGT handover Value N (PBGTHoN)


Full Name

PBGT handover Value N

Abbreviation

PBGTHoN

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008 810


This parameter indicated the value N in PBGT handover. In PBGT handover, if there are P values of PBGT in N PBGT satisfying the handover

Description

determination condition, the PBGT handover conditions are satisfied.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion
Change Mode

According to the on-site configuration experience, if the default value is


[3, 2], handover decision is made and number of handovers finished is
reasonable.
Usually, if the value is too small, times of handover attempts and
execution will be influenced. The larger the value is, it is more difficult to
perform handover, and the higher the call drop risk is.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-261
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.2.24 PBGT handover Value P (PBGTHoP)


Full Name

PBGT handover Value P

Abbreviation

PBGTHoP

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008 810


This parameter indicates the value P in PBGT handover. In PBGT handover, if there are P values of PBGT in N PBGT satisfying the handover

Description

determination condition, the PBGT handover conditions are satisfied.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion
Change Mode

According to the on-site configuration experience, if the default value is


[3, 2], handover decision is made and number of handovers finished is
reasonable.
Usually, if the value is too small, times of handover attempts and
execution will be influenced. The larger the value is, it is more difficult to
perform handover, and the higher the call drop risk is.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-262
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.2.25 Downlink rapid quality drop THS (DlQualRapidHoThs)


Full Name

Downlink rapid quality drop THS

Abbreviation

DlQualRapidHoThs

3GPP Name

None

3GPP Reference

None
This parameter indicates the threshold of downlink rapid quality drop.
Setting of the threshold is magnified 10 times, so as to reduce quality
drop span, and make the calculation of handover decision more
accurate.
If the threshold is smaller than 10, the quality is smaller than 1 and
equals to level 0; if the threshold is smaller than 20, the quality equals to

Description

level 1. Therefore, If the threshold is 70, the quality equals to level 7.

Managed Object

Cell
Threshold: 8..70

Value Range and Step

Step: 1

Unit

None

Default Value

60

Default Value
Configuration Reason

This handover belongs to emergency and rescue handover. The cell


quality and average window size should not be too large. Otherwise,
handover success rate will be influenced.

Configuration Rule and

The smaller is the threshold and value N, the easier is the quality

Adjustment Suggestion

handover, the easier is the handover of MS out of poor quality cell.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Level
Parameter Modifying
Version

None

5-263
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.3.2.26 Downlink rapid quality drop Value N (DlQualRapidHoN)


Full Name

Downlink rapid quality drop Value N

Abbreviation

DlQualRapidHoN

3GPP Name

None

3GPP Reference

None
This parameter indicates the value N of downlink rapid quality drop.
Setting of the threshold is magnified 10 times, so as to reduce quality
drop span, and make the calculation of handover decision more
accurate.
If the threshold is smaller than 10, the quality is smaller than 1 and
equals to level 0; if the threshold is smaller than 20, the quality equals to

Description

level 1. Therefore, If the threshold is 70, the quality equals to level 7.

Managed Object

Cell
Value N: 1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This handover belongs to emergency and rescue handover. The cell


quality and average window size should not be too large. Otherwise,
handover success rate will be influenced.

Configuration Rule and

The smaller is the threshold and value N, the easier is the quality

Adjustment Suggestion

handover, the easier is the handover of MS out of poor quality cell.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-264
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.2.27 Uplink receive quality for AMR-FR Threshold (HoUlQualThsForAmrFr)


Full Name

Uplink receive quality for AMR-FR Threshold

Abbreviation

HoUlQualThsForAmrFr

3GPP Name

None

3GPP Reference

None
This parameter specifies the threshold of AMR-FR UL Rx quality. Of the
UL quality average values, when the ratio of the count of values larger
than this parameter value to the total reaches P/N, a handover should be

Description

performed.

Managed Object

CELL
[8..70]

Value Range and Step

Step: 1

Unit

None

Default Value

49

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The quality with a level higher than 49 is considered bad.


The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-265
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.28 Uplink receive quality for AMR-FR Value N (HoUlQualAmrFrN)


Full Name

Uplink receive quality for AMR-FR Value N

Abbreviation

HoUlQualAmrFrN

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of N related to AMR-FR UL Rx quality.
Of the UL quality average values, when the ratio of the count of values
larger than HoUlQualThsForAmrFr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.
The greater the parameter value, the more accurate the decision and

Configuration Rule and

the poorer real-time is achieved.

Adjustment Suggestion

The smaller the parameter value, the less accurate the decision and
the better real-time is achieved.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

5-266
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.29 Uplink receive quality for AMR-FR Value P (HoUlQualAmrFrP)


Full Name

Uplink receive quality for AMR-FR Value P

Abbreviation

HoUlQualAmrFrP

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of P related to AMR-FR UL Rx quality.
Of the UL quality average values, when the ratio of the count of values
larger than HoUlQualThsForAmrFr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

Change Mode

Offline

Related features

None

Related Parameters

HoUlQualAmrFrN

Relationship

HoUlQualAmrFrP <= HoUlQualAmrFrN

Related Interfaces

None

Impact on Equipment

Impact on service

5-267
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.30 Uplink receive quality for AMR-HR Threshold (HoUlQualThsForAmrHr)


Full Name

Uplink receive quality for AMR-HR Threshold

Abbreviation

HoUlQualThsForAmrHr

3GPP Name

None

3GPP Reference

None
This parameter specifies the threshold of AMR-HR UL Rx quality. Of the
UL quality average values, when the ratio of the count of values larger
than this parameter value to the total reaches P/N, a handover should be

Description

performed.

Managed Object

CELL
[8..70]

Value Range and Step

Step: 1

Unit

None

Default Value

49

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The quality with a level higher than 49 is considered bad.


The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

5-268
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.31 Uplink receive quality for AMR-HR Value N (HoUlQualAmrHrN)


Full Name

Uplink receive quality for AMR-HR Value N

Abbreviation

HoUlQualAmrHrN

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of N related to AMR-HR UL Rx quality.
Of the UL quality average values, when the ratio of the count of values
larger than HoUlQualThsForAmrHr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.
The greater the parameter value, the more accurate the decision and

Configuration Rule and

the poorer real-time is achieved.

Adjustment Suggestion

The smaller the parameter value, the less accurate the decision and
the better real-time is achieved.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

5-269
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.32 Uplink receive quality for AMR-HR Value P (HoUlQualAmrHrP)


Full Name

Uplink receive quality for AMR-HR Value P

Abbreviation

HoUlQualAmrHrP

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of P related to AMR-HR UL Rx quality.
Of the UL quality average values, when the ratio of the count of values
larger than HoUlQualThsForAmrHr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

Change Mode

Offline

Related features

None

Related Parameters

HoUlQualAmrHrN

Relationship

HoUlQualAmrHrP <= HoUlQualAmrHrN

Related Interfaces

None

Impact on Equipment

5-270
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.33 Downlink receive quality for AMR-FR Threshold (HoDlQualThsForAmrFr)


Full Name

Downlink receive quality for AMR-FR Threshold

Abbreviation

HoDlQualThsForAmrFr

3GPP Name

None

3GPP Reference

None
This parameter specifies the threshold of AMR-FR DL Rx quality. Of the
DL quality average values, when the ratio of the count of values larger
than this parameter value to the total reaches P/N, a handover should be

Description

performed.

Managed Object

CELL
[8..70]

Value Range and Step

Step: 1

Unit

None

Default Value

49

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The quality with a level higher than 49 is considered bad.


The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

5-271
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.34 Downlink receive quality for AMR-FR Value N (HoDlQualAmrFrN)


Full Name

Downlink receive quality for AMR-FR Value N

Abbreviation

HoDlQualAmrFrN

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of N related to AMR-FR DL Rx quality.
Of the DL quality average values, when the ratio of the count of values
larger than HoDlQualThsForAmrFr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.
The greater the parameter value, the more accurate the decision and

Configuration Rule and

the poorer real-time is achieved.

Adjustment Suggestion

The smaller the parameter value, the less accurate the decision and
the better real-time is achieved.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

5-272
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.35 Downlink receive quality for AMR-FR Value P (HoDlQualAmrFrP)


Full Name

Downlink receive quality for AMR-FR Value P

Abbreviation

HoDlQualAmrFrP

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of P related to AMR-FR DL Rx quality.
Of the DL quality average values, when the ratio of the count of values
larger than HoDlQualThsForAmrFr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

Change Mode

Offline

Related features

None

Related Parameters

HoDlQualAmrFrN

Relationship

HoDlQualAmrFrP <= HoDlQualAmrFrN

Related Interfaces

None

5-273
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.36 Downlink receive quality for AMR-HR Threshold (HoDlQualThsForAmrHr)


Full Name

Downlink receive quality for AMR-HR Threshold

Abbreviation

HoDlQualThsForAmrHr

3GPP Name

None

3GPP Reference

None
This parameter specifies the threshold of AMR-HR DL Rx quality. Of the
DL quality average values, when the ratio of the count of values larger
than this parameter value to the total reaches P/N, a handover should be

Description

performed.

Managed Object

CELL
[8..70]

Value Range and Step

Step: 1

Unit

None

Default Value

49

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The quality with a level higher than 49 is considered bad.


The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

5-274
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.37 Downlink receive quality for AMR-HR Value N (HoDlQualAmrHrN)


Full Name

Downlink receive quality for AMR-HR Value N

Abbreviation

HoDlQualAmrHrN

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of N related to AMR-hR DL Rx quality.
Of the DL quality average values, when the ratio of the count of values
larger than HoDlQualThsForAmrHr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.
The greater the parameter value, the more accurate the decision and

Configuration Rule and

the poorer real-time is achieved.

Adjustment Suggestion

The smaller the parameter value, the less accurate the decision and
the better real-time is achieved.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

5-275
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.38 Downlink receive quality for AMR-HR Value P (HoDlQualAmrHrP)


Full Name

Downlink receive quality for AMR-HR Value P

Abbreviation

HoDlQualAmrHrP

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of P related to AMR-hR DL Rx quality.
Of the DL quality average values, when the ratio of the count of values
larger than HoDlQualThsForAmrHr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

Change Mode

Offline

Related features

None

Related Parameters

HoDlQualAmrHrN

Relationship

HoDlQualAmrHrP <= HoDlQualAmrHrN

5-276
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.39 Uplink receive level for AMR-FR Threshold (HoUlLevThsForAmrFr)


Full Name

Uplink receive level for AMR-FR Threshold

Abbreviation

HoUlLevThsForAmrFr

3GPP Name

None

3GPP Reference

None
This parameter specifies the threshold of AMR-FR UL Rx level. Of the
UL level average values, when the ratio of the count of values less than
this parameter value to the total reaches P/N, a handover should be per-

Description

formed.

Managed Object

CELL
[0..63]

Value Range and Step

Step: 1

Unit

None

Default Value

15

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The value -95dbm is considered a division between good and bad level.
The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

5-277
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.40 Uplink receive level for AMR-FR Value N (HoUlLevAmrFrN)


Full Name

Uplink receive level for AMR-FR Value N

Abbreviation

HoUlLevAmrFrN

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of N related to AMR-FR UL Rx level.
Of the UL level average values, when the ratio of the count of values
larger than HoUlLevThsForAmrFr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.
The greater the parameter value, the more accurate the decision and

Configuration Rule and

the poorer real-time is achieved.

Adjustment Suggestion

The smaller the parameter value, the less accurate the decision and
the better real-time is achieved.

Change Mode

Offline

Related features

None

Related Parameters

None

5-278
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.41 Uplink receive level for AMR-FR Value P (HoUlLevAmrFrP)


Full Name

Uplink receive level for AMR-FR Value P

Abbreviation

HoUlLevAmrFrP

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of P related to AMR-FR UL Rx level.
Of the UL level average values, when the ratio of the count of values
larger than HoUlLevThsForAmrFr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

Change Mode

Offline

Related features

None

Related Parameters

HoUlLevAmrFrN

5-279
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

HoUlLevAmrFrP <= HoUlLevAmrFrN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.42 Uplink receive level for AMR-HR Threshold (HoUlLevThsForAmrHr)


Full Name

Uplink receive level for AMR-HR Threshold

Abbreviation

HoUlLevThsForAmrHr

3GPP Name

None

3GPP Reference

None
This parameter specifies the threshold of AMR-HR UL Rx level. Of the
UL level average values, when the ratio of the count of values less than
this parameter value to the total reaches P/N, a handover should be per-

Description

formed.

Managed Object

CELL
[0..63]

Value Range and Step

Step: 1

Unit

None

Default Value

15

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The value -95dbm is considered a division between good and bad level.
The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

Change Mode

Offline

Related features

None

Related Parameters

None

5-280
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.43 Uplink receive level for AMR-HR Value N (HoUlLevAmrHrN)


Full Name

Uplink receive level for AMR-HR Value N

Abbreviation

HoUlLevAmrHrN

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of N related to AMR-HR UL Rx level.
Of the UL level average values, when the ratio of the count of values
larger than HoUlLevThsForAmrHr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.
The greater the parameter value, the more accurate the decision and

Configuration Rule and

the poorer real-time is achieved.

Adjustment Suggestion

The smaller the parameter value, the less accurate the decision and
the better real-time is achieved.

Change Mode

Offline

Related features

None

5-281
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.44 Uplink receive level for AMR-HR Value P (HoUlLevAmrHrP)


Full Name

Uplink receive level for AMR-HR Value P

Abbreviation

HoUlLevAmrHrP

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of P related to AMR-HR UL Rx level.
Of the UL level average values, when the ratio of the count of values
larger than HoUlLevThsForAmrHr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

Change Mode

Offline

Related features

None

5-282
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

HoUlLevAmrHrN

Relationship

HoUlLevAmrHrP <= HoUlLevAmrHrN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.45 Downlink receive level for AMR-FR Threshold (HoDlLevThsForAmrFr)


Full Name

Downlink receive level for AMR-FR Threshold

Abbreviation

HoDlLevThsForAmrFr

3GPP Name

None

3GPP Reference

None
This parameter specifies the threshold of AMR-FR DL Rx level. Of the
DL level average values, when the ratio of the count of values less than
this parameter value to the total reaches P/N, a handover should be per-

Description

formed.

Managed Object

CELL
[0..63]

Value Range and Step

Step: 1

Unit

None

Default Value

15

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The value -95dbm is considered a division between good and bad level.
The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

Change Mode

Offline

Related features

None

5-283
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.46 Downlink receive level for AMR-FR Value N (HoDlLevAmrFrN)


Full Name

Downlink receive level for AMR-FR Value N

Abbreviation

HoDlLevAmrFrN

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of N related to AMR-FR DL Rx level.
Of the DL level average values, when the ratio of the count of values
larger than HoDlLevThsForAmrFr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.
The greater the parameter value, the more accurate the decision and

Configuration Rule and

the poorer real-time is achieved.

Adjustment Suggestion

The smaller the parameter value, the less accurate the decision and
the better real-time is achieved.

Change Mode

Offline

5-284
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.47 Downlink receive level for AMR-FR Value P (HoDlLevAmrFrP)


Full Name

Downlink receive level for AMR-FR Value P

Abbreviation

HoDlLevAmrFrP

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of P related to AMR-FR DL Rx level.
Of the DL level average values, when the ratio of the count of values
larger than HoDlLevThsForAmrFr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion
Change Mode

The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.
Offline

5-285
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

None

Related Parameters

HoDlLevThsForAmrFrN

Relationship

HoDlLevAmrFrP <= HoDlLevAmrFrN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.48 Downlink receive level for AMR-HR Threshold (HoDlLevThsForAmrHr)


Full Name

Downlink receive level for AMR-HR Threshold

Abbreviation

HoDlLevThsForAmrHr

3GPP Name

None

3GPP Reference

None
This parameter specifies the threshold of AMR-HR DL Rx level. Of the
DL level average values, when the ratio of the count of values less than
this parameter value to the total reaches P/N, a handover should be per-

Description

formed.

Managed Object

CELL
[0..63]

Value Range and Step

Step: 1

Unit

None

Default Value

15

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion
Change Mode

The value -95dbm is considered a division between good and bad level.
The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.
Offline

5-286
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.49 Downlink receive level for AMR-HR Value N (HoDlLevAmrHrN)


Full Name

Downlink receive level for AMR-HR Value N

Abbreviation

HoDlLevAmrHrN

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of N related to AMR-HR DL Rx level.
Of the DL level average values, when the ratio of the count of values
larger than HoDlLevThsForAmrHr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.
The greater the parameter value, the more accurate the decision and

Configuration Rule and

the poorer real-time is achieved.

Adjustment Suggestion

The smaller the parameter value, the less accurate the decision and
the better real-time is achieved.

5-287
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.2.50 Downlink receive level for AMR-HR Value P (HoDlLevAmrHrP)


Full Name

Downlink receive level for AMR-HR Value P

Abbreviation

HoDlLevAmrHrP

3GPP Name

None

3GPP Reference

None
This parameter specifies the value of P related to AMR-HR DL Rx level.
Of the DL level average values, when the ratio of the count of values
larger than HoDlLevThsForAmrHr to the total reaches P/N, a handover

Description

should be performed.

Managed Object

CELL
[1..20]

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value can ensure the accuracy and efficiency of the

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

The greater the parameter value, the stricter the handover condition and
the handover is not easily allowed. Too large values can increase the call
drop rate, while too small values can increase unnecessary handovers.

5-288
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related features

None

Related Parameters

HoDlLevAmrHrN

Relationship

HoDlLevAmrHrP <= HoDlLevAmrHrN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover level

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.3 Handover Condition Parameters


5.3.3.1 Max time advance threshold between MS and BTS (DistanceThs)
Full Name

Max time advance threshold between MS and BTS

Abbreviation

DistanceThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008 V5.22.0


According to the GSM specifications, handover decisions depend upon
the received average value.
The distance from MS to BTS is also one of the causes for handover.
The decision process is as follows: For the latest N average values of
TA (distance), if P of the N values rises above relevant threshold value,
perform handover. The handover is due to MS being out of the cell

Description

service range.

Managed Object

Cell
Extended cell: 0..219
Normal cell: 0..63

Value Range and Step

Step: 1

Unit

None

Default Value

63
5-289

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

The default value is an experience value.

Configuration Rule and

Generally, the value is set as the time of receiving 60 measurement

Adjustment Suggestion

reports.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.2 MIN interval between inter-cell handover (HoMinInterval)


Full Name

MIN interval between inter-cell handover

Abbreviation

HoMinInterval

3GPP Name

None

3GPP Reference

None
This parameter specifies the interval value for which MS waits before
the actual inter-cell handover occurs. Such a timer is more predominant
for MS at the boundary regions between two cells, where inter-cell
handovers occur frequently. This parameter helps restrict frequent
inter-cell handover and guarantees call quality.
Inter-cell handover takes place when the timer exceeds the defined
interval value from the last inter-cell handover of MS. This parameter
affects only the inter-cell handover, but not common intra-cell or inter-cell
concentric handover.

Description

The default value value can be set to 5.

Managed Object

Cell

5-290
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

0..31
Value Range and Step

Step: 1

Unit

Default Value

Default Value
Configuration Reason

According to the on-site experience, within 5 seconds, ususally MS can


move to a better cell and does not perform handover in the serving cell
so as to avoid another handover failure.
Large value indicates a longer interval between two handovers, avoiding

Configuration Rule and

frequent handover but causing delay.

Adjustment Suggestion

Small value indicates a shorter interval between two handovers and


handover is initiated faster, causing frequent handover.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Condition
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.3 MIN interval between inter-cell emergency handover (HOMININTERVALEMERG)


Full Name

MIN interval between inter-cell emergency handover

Abbreviation

HOMININTERVALEMERG

3GPP Name

None

3GPP Reference

None

5-291
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter specifies the interval value for which MS waits before
the actual inter-cell handover occurs. Such a timer is more predominant
for MS at the boundary regions between two cells, where inter-cell
handovers occur frequently. This parameter helps restrict frequent
inter-cell handover and guarantees call quality.
Inter-cell handover takes place when the timer exceeds the defined
interval value from the last inter-cell handover of MS. This parameter
affects only the emergency inter-cell handover, but not common intra-cell
or inter-cell concentric handover.
The emergency handover includes quality handover, level handover,
intra-cell interference handover, uplink signal rapid attenuation handover,
downlink quality rapid drop handover, and handover from the second
Description

sub cell to the first sub cell.

Managed Object

Cell
0..31

Value Range and Step

Step: 1

Unit

Default Value

Default Value

If ther emergency handover is not performed, call drop occurs easily,

Configuration Reason

thereby handover is initiated only if the requirement is satisfied by default.

Configuration Rule and

Frequent handover can be avoided by adjusting this parameter.If the

Adjustment Suggestion

value is adjusted as too large, call drop occurs due to handover failure.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-292
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.3.4 Handover back penalty (HoBackPenalty)


Full Name

Handover back penalty

Abbreviation

HoBackPenalty

3GPP Name

None

3GPP Reference

None
This parameter describes the time limit for backward handover to the original cell. In other words, after handover is performed from cell A to cell
B, it is not allowed to perform backward handover from cell B to cell A.
This parameter is applicable to non-emergency handover. For emergency

Description

handover, parameter HOBACKPENALTYEMERG is used to limit the time.

Managed Object

Cell
0..60

Value Range and Step

Step: 1

Unit

Default Value

Default Value
Configuration Reason

Setting of the default value needs to avoid the increase of handover


frequency resulting from toggle handover, and to avoid call drops as
much as possible.
If the value is too small, it is easy to perform backward handover to the

Configuration Rule and

original cell, toggle handover occurs.

Adjustment Suggestion

If the value is too large, it is not easy to perform backward handover to


the original cell.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Condition
Parameter Modifying
Version

None

5-293
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.3.3.5 Handover back penalty after emergency handover (HOBACKPENALTYEMERG)


Full Name

Handover back penalty after emergency handover

Abbreviation

HOBACKPENALTYEMERG

3GPP Name

None

3GPP Reference

None
This parameter describes the time limit for backward handover to the
original cell. In other words, after emergency handover is performed
from cell A to cell B, it is not allowed to perform backward handover
from cell B to cell A.
The emergency handover includes quality handover, level handover,
intra-cell interference handover, uplink signal rapid attenuation handover,
downlink quality rapid drop handover, and handover from the second

Description

sub cell to the first sub cell.

Managed Object

Cell
0..60

Value Range and Step

Step: 1

Unit

Default Value

15

Default Value
Configuration Reason

Setting of the default value needs to avoid the increase of handover


frequency resulting from toggle handover, meanwhile, hold calls to
prevent call drop.
If the value is too small, it is easy to perform backward handover to the

Configuration Rule and


Adjustment Suggestion

original cell, toggle handover occurs.


If the value is too large, it is not easy to perform backward handover to
the original cell.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
5-294

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.6 Prior layer selecting parameter on signal level/quality (LayerPriority)


Full Name

Prior layer selecting parameter on signal level/quality

Abbreviation

LayerPriority

3GPP Name

Internal

3GPP Reference

None
This parameter decides the priority to select and sequence the candidate
cells for handover. Received signal level and signal quality decides the
candidate cells for handover. Three options are available:
First hand over to adjacent cells at the upper layer of the local cell, then
to those at the same layer, and finally to other adjacent cells;
Adjacent cells in the same layer of serving cell have the highest priority
for handover, then adjacent cells in the upper layer, and finally the other
adjacent cells.
All adjacent cells are treated in the same way.
This parameter determines to select one of above three methods.During
handover control process, this parameter has higher priority than normal
adjacent cells.
Value range:
1 (UPPER_LAYER): adjacent cell at above layer first, same layer next,
other adjacent cells finally;
2 (SAME_LAYER): adjacent cell at same layer first, above layer next,
other adjacent cells finally;
3 (ALL_LAYER): all adjacent cells are the same.
For micro-cell, option 1 is selected. When call in micro-cell is handed
over due to signal quality or signal strength, first handover to macro-cell

Description

layer.In general, macro cell adopts option 2.

Managed Object

Cell
1..3

Value Range and Step

Step: 1

Unit

None

Default Value

5-295
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

ThIS Parameter is no longer used. The default value is kept.

Configuration Rule and


Adjustment Suggestion

ThIS Parameter is no longer used. The default value is kept.

Change Mode

Offline

Related features

ZGO-02-02-002 Dynamic Handover Priority Algorithm

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.7 Handover to same layer other band neighbour cell for PBGT permitted
(PbgtHoLayer_0)
Full Name

Handover to same layer other band neighbour cell for PBGT permitted

Abbreviation

PbgtHoLayer_0

3GPP Name

Internal

3GPP Reference

None
This parameter describes whether it is allowed to perform PBGT handover

Description

to the same layer adjacent cell with different frequency band.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

Usually, PBGT handover is used at the same layer.

5-296
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and

Usually, PBGT handover is used at the same layer, so that MS can

Adjustment Suggestion

select a better cell.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.8 Handover to neighbour cell with no Layer Relation for PBGT permitted
(PbgtHoLayer_1)
Full Name

Handover to neighbour cell with no Layer Relation for PBGT permitted

Abbreviation

PbgtHoLayer_1

3GPP Name

Internal

3GPP Reference

None
This parameter describes whether it is allowed to perform PBGT handover

Description

to adjacent cell with no layer relationship.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value

The layer relationship is unclear. PBGT handover is allowed when MS

Configuration Reason

does not use the layered structure.

Configuration Rule and

Usually, after layers are set for the cell which needs PBGT handover, set

Adjustment Suggestion

not to perform PBGT handover on the undefined layer.

Change Mode

Offline
5-297

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Condition
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.9 Handover to upper layer neighbour cell for PBGT permitted (PbgtHoLayer_2)
Full Name

Handover to upper layer neighbour cell for PBGT permitted

Abbreviation

PbgtHoLayer_2

3GPP Name

Internal

3GPP Reference

None
This parameter describes whether the PBGT handover to the upper layer

Description

adjacent cell is allowed.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is used to make the lower layer absorb traffic easily.
Usually, handover to the upper layer adjacent cell is not allowed.After

Configuration Rule and

this function is disabled, the traffic under special scenario can be shared

Adjustment Suggestion

and congestion can be alleviated, but the call drop rate and coverage
rate may be influenced..

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

5-298
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Condition
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.10 Handover to under layer neighbor cell for PBGT permitted (PbgtHoLayer_3)
Full Name

Handover to under layer neighbor cell for PBGT permitted

Abbreviation

PbgtHoLayer_3

3GPP Name

Internal

3GPP Reference

None
This parameter describes whether the PBGT handover to the lower layer

Description

adjacent cell is allowed.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

Layered structure is not set for the common network. The value is "No"

Configuration Reason

by default.

Configuration Rule and


Adjustment Suggestion

Usually, in the layered network, handover to the lower layer adjacent


cell is allowed.If it is not allowed, a negative impact is brought on the
congestion rate under the special scenario.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None
5-299

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.11 Synchronism (HoPatternInd_0)


Full Name

Synchronism

Abbreviation

HoPatternInd_0

3GPP Name

None

3GPP Reference

None
This parameter indicates the configuration that whether the
synchronization handover is allowed in this cell.
If the time advance of the destination cell BSC obtained is equal to that of

Description

the original cell, synchronization handover to this cell can be performed.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

Usually, synchronization handover occurs in the common network.

Configuration Rule and

The default value is used. Usually, synchronization handover occurs in

Adjustment Suggestion

the common network, so the default value should be enabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

0
5-300

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.12 Asynchronism (HoPatternInd_1)


Full Name

Asynchronism

Abbreviation

HoPatternInd_1

3GPP Name

None

3GPP Reference

None
This parameter indicates the configuration that whether the
asynchronous handover is allowed in this cell.
If BSC is unable to obtain the time advance of the destination cell,

Description

asynchronous handover can be only performed to this cell.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

Usually, asynchronous handover occurs in the common network.

Configuration Rule and

The default value is used. Usually, synchronization handover occurs in

Adjustment Suggestion

the common network, so the default value should be enabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
5-301

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.13 Pseudo-synchronism (HoPatternInd_2)


Full Name

Pseudo-synchronism

Abbreviation

HoPatternInd_2

3GPP Name

None

3GPP Reference

None
This parameter indicates the configuration that whether the
pseudo-synchronization handover is supported in the cell.
If the MS is able to calculate the time advance of the target cell and it
supports pseudo-synchronization handover, the pseudo-synchronization

Description

handover can be performed in the cell.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

The default value is dependent upon the actual request on site.

Configuration Rule and


Adjustment Suggestion

Currently, this function is not supported and is disabled.

Change Mode

Offline

Related features

ZGB-02-02-003 Handover Mode

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-302
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.14 Pseudo-synchronism (HoPatternInd_3)


Full Name

Pseudo-synchronism

Abbreviation

HoPatternInd_3

3GPP Name

None

3GPP Reference

None
This parameter indicates the configuration that whether the
pre-synchronization handover is allowed in this cell.
If BSC knows the time advance of the destination cell, and considers the
time difference when it issues handover command, pre-synchronization

Description

handover can be performed

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

The default value is used, and usually it is disabled. At present, this

Adjustment Suggestion

function cannot be supported.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-303
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.15 Downlink rapid handover threshold (DLRapidHoThs)


Full Name

Downlink rapid handover threshold

Abbreviation

DLRapidHoThs

3GPP Name

None

3GPP Reference

None
Downlink rapid handover decisions depend upon a series measurement
reports received.
Downlink rapid is one of the causes for handover. The decision process
is as follows: If the latest successive N downlink level values (without
average processing) are larger than the sum of relating threshold and
the offset, perform handover with the cause of downlink rapid handover.
This parameter DLRapidHoThs defines the threshold.

Description

Since the version V6.20.614b, this parameter is supported.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

10

Default Value

Usually, -100dbm is considered as the demarcation point between the

Configuration Reason

good uplink level and poor uplink level.


The value the larger is, the handover is more unlikely to occur, and vice

Configuration Rule and

versa the handover is easier to occur.If the value is too large, quantity

Adjustment Suggestion

of call drops may rise. If the value is too small, excessive handovers
may occur.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

5-304
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.16 Downlink rapid handover N (DLRapidHoN)


Full Name

Downlink rapid handover N

Abbreviation

DLRapidHoN

3GPP Name

None

3GPP Reference

None
SDCCH downlink rapid handover decisions depend upon a series
measurement reports received.
Downlink rapid is one of the causes for handover. The decision process
is as follows: If the latest successive N downlink level values (without
average processing) are larger than the sum of relating threshold and
the offset, perform handover with the cause of downlink rapid handover.
This parameter DLRapidHoN defines the value N.

Description

Since the version V6.20.614b, this parameter is supported.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value as this, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.

Configuration Rule and


Adjustment Suggestion
Change Mode

The larger the value is, the more is the accuracy of handover decision,
the lower is the realtime; The smaller the value is, the less is the
accuracy of handover decision, the higher is the realtime.
Offline

5-305
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoControl_23

Relationship

This parameter is valid till the downlink rapid handover is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Condition
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.17 Downlink rapid handover offset of high speed (DLRapidHoOffset_0)


Full Name

Downlink rapid handover offset of high speed

Abbreviation

DLRapidHoOffset_0

3GPP Name

None

3GPP Reference

None
Downlink rapid handover decisions depend upon a series measurement
reports received.
Downlink rapid is one of the causes for handover. The decision process
is as follows: If the latest successive N downlink level values (without
average processing) are larger than the sum of relating threshold and
the offset, perform handover with the cause of downlink rapid handover.
This parameter DLRapidHoOffset_0 defines the offset threshold value

Description

for downlink rapid handover if the train speed is higher than 250km/hr.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Usually, if MS moves at a high speed, handover should be triggered


rapidly, thereby it is better to set the offset value to a relatively small
value to assist in making handover decisions.
5-306

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and


Adjustment Suggestion

For the threshold under high speed scenario, rapid handover should be
performed, thereby it is better to set the offset value to a relatively small
value to assist in making handover decisions.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.18 Downlink rapid handover offset of middle speed (DLRapidHoOffset_1)


Full Name

Downlink rapid handover offset of middle speed

Abbreviation

DLRapidHoOffset_1

3GPP Name

Internal

3GPP Reference

None
Downlink rapid handover decisions depend upon a series measurement
reports received.
Downlink rapid is one of the causes for handover. The decision process
is as follows: If the latest successive N downlink level values (without
average processing) are larger than the sum of relating threshold and
the offset, perform handover with the cause of downlink rapid handover.
This parameter DLRapidHoOffset_1 defines the offset threshold value
for downlink rapid handover if the train speed is between 150km/hr
and 250km/hr.

Description

Since the version V6.20.614b, this parameter is supported.

Managed Object

Cell

5-307
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0..63
Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Setting of the default value is in accordance with the radio environment

Configuration Reason

that mostly the speed is 150..250km/h under the high-speed scenario.


The value is applicable to the coverage area under such high-speed

Configuration Rule and

scenarios as expressways, and high-speed railways on which the train

Adjustment Suggestion

speed is 150..250 km/h.


Higher speed requires a smaller offset value to realize a faster handover.

Change Mode

Offline

Related features

ZGO-02-02-018 Handover Based on Downlink Level Fast Fading

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.3.19 Downlink rapid handover offset of low speed (DLRapidHoOffset_2)


Full Name

Downlink rapid handover offset of low speed

Abbreviation

DLRapidHoOffset_2

3GPP Name

None

3GPP Reference

None

5-308
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Downlink rapid handover decisions depend upon a series measurement


reports received.
Downlink rapid is one of the causes for handover. The decision process
is as follows: If the latest successive N downlink level values (without
average processing) are larger than the sum of relating threshold and
the offset, perform handover with the cause of downlink rapid handover.
This parameter DLRapidHoOffset_2 defines the offset threshold value
Description

for downlink rapid handover if the train speed is lower than 150km/hr.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Setting of the default value is in accordance with the radio environment


that mostly the speed is lower than 150 km/h under the high-speed
scenario.
The value is applicable to the coverage area under such high-speed

Configuration Rule and

scenarios as expressways, and high-speed railways on which the train

Adjustment Suggestion

speed is lower than 150 km/h.


Higher speed requires a smaller offset value to realize a faster handover.

Change Mode

Offline

Related features

ZGO-02-02-018 Handover Based on Downlink Level Fast Fading

Related Parameters

[Cell]HoControl_23

Relationship

This parameter is valid till the downlink rapid handover is supported.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Condition
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-309
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.3.20 Downlink rapid handover enable (HoControl_23)


Full Name

Downlink rapid handover enable

Abbreviation

HoControl_23

3GPP Name

None

3GPP Reference

None
This parameter determines whether downlink rapid handover is allowed
to enable.

Description

It is the 23rd bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

The downlink rapid handover switch is only enabled under the

Configuration Reason

high-speed scenario.
This handover is mainly applied to the high-speed scenario. This
handover algorithm requires the areas along the railway are covered

Configuration Rule and

by sites in link shape, and the adjacent cell has enough overlapped

Adjustment Suggestion

coverage areas.Handover decisions can be made faster through


configuring the adjacent cell with the direction attribute, so as to enhance
handover success rate.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-310
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.3.21 The threshold for starting Downlink Rapid handover (DLRapidHoStartThs)


Full Name

The threshold for starting Downlink Rapid handover

Abbreviation

DLRapidHoStartThs

3GPP Name

None

3GPP Reference

None
This parameter determines the threshold of TCH downlink level in the
case of rapid handover. Downlink level rapid handover is a new handover algorithm for the high-speed railway scenario. In this scenario, it is
required to configure different offsets for high, medium, and low speeds to
adapt to rapid attenuation of the downlink level. In addition, handover is

Description

only triggered between cells in the dedicated high-speed railway network.

Managed Object

Cell
0..63
0: < -110 dBm;
1: -110 dBm..-109 dBm;
2: -109 dBm..-108 dBm;
......
62: -49 dBm..-48 dBm;

Value Range and Step

63: > -48 dBm

Unit

None

Default Value

63

Default Value
Configuration Reason

It is a functional parameter and is configured to 63 by default. Only when


downlink rapid handover is enabled, the system will implement handover
judgment for adjacent cells.

Configuration Rule and

It is required to configure this parameter according to the network

Adjustment Suggestion

planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

5-311
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.3.22 High speed threshold (HighSpeedThs)


Full Name

High speed threshold

Abbreviation

HighSpeedThs

3GPP Name

None

3GPP Reference

None
This parameter determines whether a subscriber moves at high speed. If
the moving speed of a subscriber is larger than this threshold, the system

Description

considers this scenario as a high-speed scenario.

Managed Object

Cell

Value Range and Step

1..255

Unit

10km/h

Default Value

25

Default Value
Configuration Reason

According to experienced values, the system considers a scenario as


a high-speed scenario if the moving speed of a subscriber is faster
than 250 km/h.

Configuration Rule and


Adjustment Suggestion

Currently, this parameter is not used and need not be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Condition
Parameter Modifying
Version

iBSCV6.20.615

5-312
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

New

5.3.3.23 Middle speed threshold (MidSpeedThs)


Full Name

Middle speed threshold

Abbreviation

MidSpeedThs

3GPP Name

None

3GPP Reference

None
This parameter determines whether a subscriber moves at medium
speed. If the moving speed of a subscriber is larger than this threshold,

Description

the system considers this scenario as a medium-speed scenario.

Managed Object

Cell

Value Range and Step

0..255

Unit

10km/h

Default Value

15

Default Value
Configuration Reason

According to experienced values, the system considers a scenario as


a medium-speed scenario if the moving speed of a subscriber is faster
than 150 km/h.

Configuration Rule and


Adjustment Suggestion

Currently, this parameter is not used and need not be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5-313
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.3.24 The minimum interval of direction handover (DirHoMinInterval)


Full Name

The minimum interval of direction handover

Abbreviation

DirHoMinInterval

3GPP Name

None

3GPP Reference

None
When the last handover has a direction, the system uses this parameter
to restrict frequent inter-cell handover, and guarantee the communication
quality and system performance, so as to prevent the MS from
performing handover to other cells soon after it handovers to this cell.
Usually, such a case occurs at the edge of two cells.
This parameter defines a period. Only when the time since last inter-cell
handover of an MS exceeds this value, another inter-cell handover is
allowed. This parameter only affects the inter-cell handover, but not
common intra-cell or inter-cell concentric handover.

Description

The default value can be configured to 5.

Managed Object

Cell

Value Range and Step

0..31

Unit

Default Value

Default Value
Configuration Reason

According to the on-site experience, within 5 seconds, an MS can move


to a cell with better signal quality and does not perform handover to this
cell, so as to avoid another handover failure.

Configuration Rule and


Adjustment Suggestion

Currently, this parameter is not used and need not be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Condition
Parameter Modifying
Version

iBSCV6.20.615

5-314
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

New

5.3.3.25 The ncell offset for downlink rapid handover (DLRapidHoNcellOffset)


Full Name

The ncell offset for downlink rapid handover

Abbreviation

DLRapidHoNcellOffset

3GPP Name

None

3GPP Reference

None
The current scenario is a high-speed scenario or the last handover is a
handover with specific direction. When the system performs sorting in the
target cell, with this offset, handover to the adjacent cell configured as a

Description

high-speed dedicated network cell is easier.

Managed Object

Cell

Value Range and Step

0..60

Unit

None

Default Value

24

Default Value
Configuration Reason

The meaning of 24 is the same as that of 0. This parameter is currently


not used and will be configured in the future according to network
planning.

Configuration Rule and


Adjustment Suggestion

Currently, this parameter is not used and need not be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Condition
Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New
5-315

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.3.26 The offset of ncell in the same direction (SameDirNcellOffset)


Full Name

The offset of ncell in the same direction

Abbreviation

SameDirNcellOffset

3GPP Name

None

3GPP Reference

None
The last handover is a handover with specific direction. When the system
performs sorting in the target cell, with this offset, handover to the target

Description

cell with the same direction as that of the handover is easier.

Managed Object

Cell

Value Range and Step

0..60

Unit

None

Default Value

24

Default Value
Configuration Reason

The meaning of 24 is the same as that of 0. This parameter is currently


not used and will be configured in the future according to network
planning.

Configuration Rule and


Adjustment Suggestion

Currently, this parameter is not used and need not be adjusted.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Condition

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5-316
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.4 Handover Control Parameters


5.3.4.1 Allow intra-Cell handover attempt due to uplink interference (HoControl_1)
Full Name

Allow intra-Cell handover attempt due to uplink interference

Abbreviation

HoControl_1

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the intra-cell TCH handover due to up-

Description

link interference can be performed.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

The value is recommended to set to No.

Configuration Rule and


Adjustment Suggestion

This function is suggested to close without special need.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.2 Allow intra-Cell handover attempt due to downlink interference (HoControl_2)


Full Name

Allow intra-Cell handover attempt due to downlink interference


5-317

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

HoControl_2

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow intra-cell handover attempt

Description

due to downlink interference.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

The value is recommended to set to No.

Configuration Rule and


Adjustment Suggestion

This function is suggested to close without special need.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.3 Allow handover due to distance (HoControl_3)


Full Name

Allow handover due to distance

Abbreviation

HoControl_3

3GPP Name

None

3GPP Reference

None

5-318
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter determines whether to allow handover due to distance.


Description

It is the 3rd bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Unless otherwise required, this switch should not be enabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.4 Allow standard PBGT handover (HoControl_4)


Full Name

Allow standard PBGT handover

Abbreviation

HoControl_4

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow standard PBGT handover.

Description

It is the 4th bit of the HoControl field in DWORD type.

Managed Object

Cell
5-319

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

1: Yes

Default Value

It is the most common handover, so the default value is enabled by

Configuration Reason

default.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.5 Allow automatic handover due to traffic (HoControl_5)


Full Name

Allow automatic handover due to traffic

Abbreviation

HoControl_5

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow automatic handover based

Description

on traffic.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No
5-320

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

The cell traffic is not too high in the common network, so this handover

Configuration Reason

is not enabled.

Configuration Rule and


Adjustment Suggestion

It is recommended to enable traffic handover, together with dynamic


priority, under the scenario with balance traffic needed of dense urban
areas.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.6 Allow intra-cell handover in super TRX channel due to downlink interference
(HoControl_8)
Allow intra-cell handover in super TRX channel due to downlink interferFull Name

ence

Abbreviation

HoControl_8

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow intra-cell handover in super
TRX channel due to downlink interference.

Description

It is the 8th bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

5-321
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.7 Allow intra-cell handover in super TRX channel due to uplink interference
(HoControl_9)
Full Name

Allow intra-cell handover in super TRX channel due to uplink interference

Abbreviation

HoControl_9

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow intra-cell handover in super
TRX channel due to uplink interference.

Description

It is the 9th bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No
5-322

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.8 Allow adjacent cells handover in super TRX channel due to PBGT
(HoControl_10)
Full Name

Allow adjacent cells handover in super TRX channel due to PBGT

Abbreviation

HoControl_10

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow adjacent cells handover in
super TRX channel due to PBGT.

Description

It is the 10th bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

5-323
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.9 Allow dynamic adjustment of handover priority (HoControl_11)


Full Name

Allow dynamic adjustment of handover priority

Abbreviation

HoControl_11

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow dynamic adjustment of
handover priority.

Description

It is the 11th bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


5-324

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and

For the network with relatively high handover congestion, it is

Adjustment Suggestion

recommended to enable this switch.

Change Mode

Offline

Related features

ZGO-02-02-002 Dynamic Handover Priority Algorithm

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.10 Allow rapid handover (HoControl_12)


Full Name

Allow rapid handover

Abbreviation

HoControl_12

3GPP Name

None

3GPP Reference

None
This parameter indicates whether to allow uplink level rapid handover.

Description

It is the 12th bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Uplink rapid attenuation handover is mainly applied to the rapid

Adjustment Suggestion

attenuation due to fast moving, strong directionality, and blocking.

Change Mode

Offline
5-325

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGO-02-02-006 Rapid Level Drop Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.11 Allow Macro-Micro delay handover (HoControl_13)


Full Name

Allow Macro-Micro delay handover

Abbreviation

HoControl_13

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow Macro-Micro delay
handover.

Description

It is the 13th bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


The macro-micro handover is to share traffic of the dual-layer or

Configuration Rule and


Adjustment Suggestion

multilayer network. Its main application scenario is the dual-frequency


network in urban areas.
If the macro-micro handover delay switch is enabled, congestion can be
eased but the coverage rate will be influenced.

5-326
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related features

ZGO-02-02-001 Handover Between Macro- and Micro-cells

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.12 Allow Micro-Micro delay handover (HoControl_14)


Full Name

Allow Micro-Micro delay handover

Abbreviation

HoControl_14

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow Micro-Micro delay handover.

Description

It is the 14th bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is disabled.

Change Mode

Offline

Related features

None

5-327
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.13 Allow force transfer handover (HoControl_16)


Full Name

Allow force transfer handover

Abbreviation

HoControl_16

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow forced transfer handover.

Description

It is the 16th bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


Generally, this switch is disabled.

Configuration Rule and

In the case of 1800 M and 900 M network sharing site, it is better to

Adjustment Suggestion

handover subscribers of 900 M network to 1800 M network.At this time,


you can transfer traffic by force.

Change Mode

Offline

Related features

ZGO-02-02-003 Directed-Shift Handover

5-328
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.14 Allow quality handover in uplink (HoControl_19)


Full Name

Allow quality handover in uplink

Abbreviation

HoControl_19

3GPP Name

None

3GPP Reference

None
This parameter describes whether quality handover in uplink is allowed.

Description

It is the 19th bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

The uplink quality handover is the most common handover, so the

Configuration Reason

default value is enabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, quality handover in uplink is set to be allowed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None
5-329

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.15 Allow level handover in uplink (HoControl_20)


Full Name

Allow level handover in uplink

Abbreviation

HoControl_20

3GPP Name

None

3GPP Reference

None
This parameter describes whether level handover in uplink is allowed.

Description

It is the 20th bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

The Uplink level handover is the most common handover, so the default

Configuration Reason

value is enabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, level handover in uplink is set to be allowed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

5-330
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.16 Allow quality handover in downlink (HoControl_21)


Full Name

Allow quality handover in downlink

Abbreviation

HoControl_21

3GPP Name

None

3GPP Reference

None
This parameter describes whether quality handover in downlink is
allowed.

Description

It is the 21st bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

The downlink quality handover is the most common handover, so the

Configuration Reason

default value is enabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, quality handover in downlink is set to be allowed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
5-331

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.17 Allow level handover in downlink (HoControl_22)


Full Name

Allow level handover in downlink

Abbreviation

HoControl_22

3GPP Name

None

3GPP Reference

None
This parameter describes whether level handover in downlink is allowed.

Description

It is the 22nd bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

The downlink level handover is the most common handover, so the

Configuration Reason

default value is enabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, level handover in downlink is set to be allowed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Control
5-332
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.18 C/I Limited Handover Support (HoControl_24)


Full Name

C/I Limited Handover Support

Abbreviation

HoControl_24

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the handover function of C/I limited
adjacent cell is supported.Suppose A is the serving cell, B and C are the
adjacent cells of this serving cell. If B and C both meet the handover
prerequisite, and the C/I limited adjacent cell threshold is satisfied,
the cell C should be filtered when the neighbor cell is chosen for the
handover.
It is the 24th bit of the HoControl field in DWORD type.

Description

Since the version V6.20.21, this parameter is supported.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


Under the turnoff scenario, this function can be enabled for individual
cells in order to prevent the tangential cross-coverage cell.Generally, this
function should not be set.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

5-333
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.19 Allow downlink quality rapid handover (HoControl_25)


Full Name

Allow downlink quality rapid handover

Abbreviation

HoControl_25

3GPP Name

None

3GPP Reference

None
Call drop occurs due to downlink quality becomes poor after call is
connected a short while or MS is handed over to cells with strong
interference areas.In this case, downlink quality rapid handover
algorithm is newly added to perform rescue handover. The quality rapid
handover depends on the original measurement value of quality, the
adjacent cell does not use windows, and N value and the N value of
handover decison are shared. Currently, other handover decisons take
priority over the downlink quality rapid handover.
This parameter indicates whether to perform downlink quality rapid
handover.

Description

This parameter is used for TCH handover.

Managed Object

Cell

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value

The default value is only enabled for the cell of poor downlink quality,

Configuration Reason

rather than common cells.

Configuration Rule and

Generally, This switch is enabled only when downlink quality is poor and

Adjustment Suggestion

strong interference occurs to the cell.

Change Mode

Offline

Related features

None

Related Parameters

None

5-334
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.20 Allow intra-Cell handover attempt due to uplink interference (HoControl[1]_1)


Full Name

Allow intra-Cell handover attempt due to uplink interference

Abbreviation

HoControl[1]_1

3GPP Name

None

3GPP Reference

None
This parameter determines whether to trigger the intra-cell TCH handover

Description

because of uplink interference in the case of medium speed.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This function is enabled, so as to reduce uplink interference of the cell.


For networks configured with frequency hopping and single-carrier cells,
it is recommended that the intra-cell handover be enabled. In other
cases, enable this function, so as to improve communication quality.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

5-335
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.21 Allow intra-Cell handover attempt due to downlink interference


(HoControl[1]_2)
Full Name

Allow intra-Cell handover attempt due to downlink interference

Abbreviation

HoControl[1]_2

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow the intra-cell TCH handover

Description

due to uplink interference in the case of medium speed.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

It is the most common handover type. By default, this function is enabled.


For networks configured with frequency hopping and single-carrier cells,
it is recommended that the intra-cell handover be disabled. In other
cases, enable this function, so as to improve communication quality.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

5-336
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.22 Allow handover due to distance (HoControl[1]_3)


Full Name

Allow handover due to distance

Abbreviation

HoControl[1]_3

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow handover due to distance in
the case of medium speed.

Description

It is the 3rd bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Unless otherwise specified, this switch should not be enabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-337
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.23 Allow standard PBGT handover (HoControl[1]_4)


Full Name

Allow standard PBGT handover

Abbreviation

HoControl[1]_4

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow standard PBGT handover in
the case of medium speed.

Description

It is the 4th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

It is the most common handover type. By default, this function is enabled.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is enabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control
5-338

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.24 Allow automatic handover due to traffic (HoControl[1]_5)


Full Name

Allow automatic handover due to traffic

Abbreviation

HoControl[1]_5

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow automatic TCH handover

Description

based on traffic in the case of medium speed.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

The cell load is not too high in a common network, and thus the

Configuration Reason

handover is not required.

Configuration Rule and

It is recommended that traffic handover be enabled, together with

Adjustment Suggestion

dynamic priority, for traffic balance in dense urban areas.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

5-339
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

5.3.4.25 Allow intra-cell handover in super TRX channel due to downlink interference
(HoControl[1]_8)
Allow intra-cell handover in super TRX channel due to downlink interferFull Name

ence

Abbreviation

HoControl[1]_8

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow intra-cell handover in super
TRX channel due to downlink interference in the case of medium speed.

Description

It is the 8th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

5-340
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

New

5.3.4.26 Allow intra-cell handover in super TRX channel due to uplink interference
(HoControl[1]_9)
Full Name

Allow intra-cell handover in super TRX channel due to uplink interference

Abbreviation

HoControl[1]_9

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow intra-cell handover in super
TRX channel due to uplink interference in the case of medium speed.

Description

It is the 9th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Control
Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New
5-341

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.4.27 Allow adjacent cells handover in super TRX channel due to PBGT
(HoControl[1]_10)
Full Name

Allow adjacent cells handover in super TRX channel due to PBGT

Abbreviation

HoControl[1]_10

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow adjacent cell handover in
super TRX channel due to PBGT in the case of medium speed.

Description

It is the 10th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5-342
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.4.28 Allow rapid handover (HoControl[1]_12)


Full Name

Allow rapid handover

Abbreviation

HoControl[1]_12

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow rapid handover between
uplink and downlink levels in the case of medium speed.

Description

It is the 12th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This parameter is a functional switch, which is disabled by default.


The uplink rapid-attenuation handover is mainly applied in the scenarios
that are characterized by quick moving speed, strong directionality, and
rapid attenuation caused by blocking.

Change Mode

Offline

Related features

ZGO-02-02-006 Rapid Level Drop Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5-343
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.4.29 Allow Macro-Micro delay handover (HoControl[1]_13)


Full Name

Allow Macro-Micro delay handover

Abbreviation

HoControl[1]_13

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow macro-micro delay
handover in the case of medium speed.

Description

It is the 13th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.


The macro-micro handover is to share traffic in the dual-layer or

Configuration Rule and


Adjustment Suggestion

multi-layer network. Its main application scenario is the dual-frequency


network in urban areas.
If the macro-micro handover delay switch is enabled, congestion can be
eased but the coverage rate will be affected.

Change Mode

Offline

Related features

ZGO-02-02-001 Handover Between Macro- and Micro-cells

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Control
Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5-344
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.4.30 Allow Micro-Micro delay handover (HoControl[1]_14)


Full Name

Allow Micro-Micro delay handover

Abbreviation

HoControl[1]_14

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow micro-micro delay handover
in the case of medium speed.

Description

It is the 14th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.31 Allow force transfer handover (HoControl[1]_16)


Full Name

Allow force transfer handover

5-345
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

HoControl[1]_16

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow forced transfer handover in
the case of medium speed.

Description

It is the 16th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.


Generally, this switch is disabled.
In the case of site sharing for 1800M and 900M networks, it is better to

Configuration Rule and

transfer the subscribers around the BTS directly to the 1800M network

Adjustment Suggestion

because the signal quality in this network is relatively good when


compared with that (better) in the 1800M network. At this time, it is
required to forcibly transfer traffic.

Change Mode

Offline

Related features

ZGO-02-02-003 Directed-Shift Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5-346
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.4.32 Subcell handover aigorithm (HoControl[1]_17)


Full Name

Subcell handover aigorithm

Abbreviation

HoControl[1]_17

3GPP Name

None

3GPP Reference

None
This parameter defines two handover modes of inter-subcell handover
algorithm in the case of medium speed: One is based on C/I, and the

Description

other is based on path loss and TA.

Managed Object

Cell

Value Range and Step

Concentric handover, Handover based on path loss and TA

Unit

None

Default Value

Concentric handover

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The default value is handover based on C/I. It is recommended that the


handover mode be changed to handover based on path loss and TA
because this algorithm is relatively mature.
It is recommended that the handover mode be changed to handover
based on path loss and TA. Currently, this handover algorithm is widely
used for COBCCH handovers on site.

Change Mode

Offline

Related features

ogy

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

ZGO-04-02-005 Co-BCCH & ZGO-05-02-009 Concentric Circle Technol-

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Subcell parameters

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5-347
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.4.33 Allow quality handover in uplink (HoControl[1]_19)


Full Name

Allow quality handover in uplink

Abbreviation

HoControl[1]_19

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow uplink quality handover in
the case of medium speed.

Description

It is the 19th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

It is the most common handover type. By default, this function is enabled.

Configuration Rule and


Adjustment Suggestion

Generally, the uplink quality handover is allowed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.34 Allow level handover in uplink (HoControl[1]_20)


Full Name

Allow level handover in uplink

5-348
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Abbreviation

HoControl[1]_20

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow uplink level handover in
the case of medium speed.

Description

It is the 20th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

It is the most common handover type. By default, this function is enabled.

Configuration Rule and


Adjustment Suggestion

Generally, the uplink level handover is allowed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.35 Allow quality handover in downlink (HoControl[1]_21)


Full Name

Allow quality handover in downlink

Abbreviation

HoControl[1]_21

3GPP Name

None

5-349
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

None
This parameter determines whether to allow downlink quality handover
in the case of medium speed.

Description

It is the 21st bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

It is the most common handover type. By default, this function is enabled.

Configuration Rule and


Adjustment Suggestion

Generally, the downlink quality handover is allowed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.36 Allow level handover in downlink (HoControl[1]_22)


Full Name

Allow level handover in downlink

Abbreviation

HoControl[1]_22

3GPP Name

None

3GPP Reference

None

5-350
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter determines whether to allow downlink level handover in


the case of medium speed.
Description

It is the 22nd bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

It is the most common handover type. By default, this function is enabled.

Configuration Rule and


Adjustment Suggestion

Generally, the downlink level handover is allowed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.37 Downlink rapid handover enable (HoControl[1]_23)


Full Name

Downlink rapid handover enable

Abbreviation

HoControl[1]_23

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow downlink rapid handover in
the case of medium speed.

Description

It is the 23rd bit in the HoControl field of DWORD type.


5-351

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

In the high-speed railway scenario, enable this switch. In other

Configuration Reason

scenarios, disable this switch.


This handover is mainly applied in the high-speed railway scenario.
This handover algorithm requires that the areas along the railway are

Configuration Rule and

covered by sites in link shape, and the adjacent cells have enough

Adjustment Suggestion

overlapped coverage areas. By configuring adjacent cells with the


direction attribute, you can improve the speed of handover judgment
and handover success rate.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Condition
Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.38 C/I Limited Handover Support (HoControl[1]_24)


Full Name

C/I Limited Handover Support

Abbreviation

HoControl[1]_24

3GPP Name

None

3GPP Reference

None

5-352
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter determines whether to support the handover function


of C/I limited adjacent cells in the case of medium speed. Suppose
that A is the serving cell, B and C are the adjacent cells of this serving
cell, and B is the C/I limited adjacent cell of C. If B and C both meet the
handover requirement, and the threshold of C/I limited adjacent cell is
also met, adjacent cell C should be filtered when the adjacent cell is
chosen for handover.
It is the 24th bit in the HoControl field of DWORD type.
Description

Since the version V6.20.21, this parameter is supported.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This parameter is a functional switch, which is disabled by default.


In the turnoff scenario, this function can be enabled for individual cells,
so as to prevent handover to a cross-coverage cell. Generally, this
function should not be configured.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.39 Allow downlink quality rapid handover (HoControl[1]_25)


Full Name

Allow downlink quality rapid handover


5-353

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

HoControl[1]_25

3GPP Name

None

3GPP Reference

None
Some cells have strong interference areas. Therefore, call drop occurs
due to poor downlink quality after handover to these cells is implemented
or a call is connected for a while. To solve this problem, add an algorithm
of downlink rapid quality handover for rescue handover in the case of
medium speed. The rapid quality handover depends on the original
measurement value of quality, the adjacent cell does not use windows,
and N value and the N value of handover judgment are shared. Currently,
other handovers are prior to the downlink rapid quality handover.
This parameter determines whether to perform downlink rapid quality
handover.

Description

This parameter is used for TCH handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

This function is enabled only in the cells with poor downlink quality. For

Configuration Reason

common cells, it is not required to enable this function.

Configuration Rule and

Generally, this switch is enabled only when the downlink quality of this

Adjustment Suggestion

cell is poor and meanwhile strong interference exists.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New
5-354

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.4.40 Allow intra-Cell handover attempt due to uplink interference (HoControl[2]_1)


Full Name

Allow intra-Cell handover attempt due to uplink interference

Abbreviation

HoControl[2]_1

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow intra-cell TCH handover due

Description

to uplink interference in the case of high speed.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This function is enabled, so as to reduce uplink interference of the cell.


For networks configured with frequency hopping and single-carrier cells,
it is recommended that the intra-cell handover be disabled. In other
cases, enable this function, so as to improve communication quality.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5-355
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.4.41 Allow intra-Cell handover attempt due to downlink interference


(HoControl[2]_2)
Full Name

Allow intra-Cell handover attempt due to downlink interference

Abbreviation

HoControl[2]_2

3GPP Name

None

3GPP Reference

None

Description

to downlink interference in the case of high speed.

Managed Object

Cell

This parameter determines whether to allow intra-cell TCH handover due

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

It is the most common handover type. By default, this function is enabled.


For networks configured with frequency hopping and single-carrier cells,
it is recommended that the intra-cell handover be disabled. In other
cases, enable this function, so as to improve communication quality.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5-356
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.4.42 Allow handover due to distance (HoControl[2]_3)


Full Name

Allow handover due to distance

Abbreviation

HoControl[2]_3

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow handover due to distance
in the case of high speed.

Description

It is the 3rd bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Unless otherwise specified, this switch should not be enabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.43 Allow standard PBGT handover (HoControl[2]_4)


Full Name

Allow standard PBGT handover

5-357
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

HoControl[2]_4

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow standard PBGT handover
in the case of high speed.

Description

It is the 4th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

It is the most common handover type. By default, this function is enabled.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is enabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.44 Allow automatic handover due to traffic (HoControl[2]_5)


Full Name

Allow automatic handover due to traffic

Abbreviation

HoControl[2]_5

3GPP Name

None

5-358
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Reference

None
This parameter determines whether to allow automatic TCH handover

Description

based on traffic in the case of high speed.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

The cell load is not too high in a common network, and thus the

Configuration Reason

handover is not required.

Configuration Rule and

It is recommended that traffic handover be enabled, together with

Adjustment Suggestion

dynamic priority, for traffic balance in dense urban areas.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.45 Allow intra-cell handover in super TRX channel due to downlink interference
(HoControl[2]_8)
Allow intra-cell handover in super TRX channel due to downlink interferFull Name

ence

Abbreviation

HoControl[2]_8

3GPP Name

None

3GPP Reference

None

5-359
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines whether to allow intra-cell handover in super


TRX channel due to downlink interference in the case of high speed.
Description

It is the 8th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.46 Allow intra-cell handover in super TRX channel due to uplink interference
(HoControl[2]_9)
Full Name

Allow intra-cell handover in super TRX channel due to uplink interference

Abbreviation

HoControl[2]_9

3GPP Name

None

3GPP Reference

None

5-360
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter determines whether to allow intra-cell handover in super


TRX channel due to uplink interference in the case of high speed.
Description

It is the 9th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.47 Allow adjacent cells handover in super TRX channel due to PBGT
(HoControl[2]_10)
Full Name

Allow adjacent cells handover in super TRX channel due to PBGT

Abbreviation

HoControl[2]_10

3GPP Name

None

3GPP Reference

None

5-361
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines whether to allow adjacent cell handover in


super TRX channel due to PBGT in the case of high speed.
Description

It is the 10th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.48 Allow rapid handover (HoControl[2]_12)


Full Name

Allow rapid handover

Abbreviation

HoControl[2]_12

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow rapid handover between
uplink and downlink levels in the case of high speed.

Description

It is the 12th bit in the HoControl field of DWORD type.


5-362

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This parameter is a functional switch, which is disabled by default.


The uplink rapid-attenuation handover is mainly applied in the scenarios
that are characterized by quick moving speed, strong directionality, and
rapid attenuation caused by blocking.

Change Mode

Offline

Related features

ZGO-02-02-006 Rapid Level Drop Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.49 Allow Macro-Micro delay handover (HoControl[2]_13)


Full Name

Allow Macro-Micro delay handover

Abbreviation

HoControl[2]_13

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow macro-micro delay
handover in the case of high speed.

Description

It is the 13th bit in the HoControl field of DWORD type.

Managed Object

Cell

5-363
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.


The macro-micro handover is to share traffic in the dual-layer or

Configuration Rule and


Adjustment Suggestion

multi-layer network. Its main application scenario is the dual-frequency


network in urban areas.
If the macro-micro handover delay switch is enabled, congestion can be
eased but the coverage rate will be affected.

Change Mode

Offline

Related features

ZGO-02-02-001 Handover Between Macro- and Micro-cells

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.50 Allow Micro-Micro delay handover (HoControl[2]_14)


Full Name

Allow Micro-Micro delay handover

Abbreviation

HoControl[2]_14

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow micro-micro delay handover
in the case of high speed.

Description

It is the 14th bit in the HoControl field of DWORD type.

Managed Object

Cell
5-364

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this switch is disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.51 Allow force transfer handover (HoControl[2]_16)


Full Name

Allow force transfer handover

Abbreviation

HoControl[2]_16

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow forced transfer handover
in the case of high speed.

Description

It is the 16th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

5-365
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.


Generally, this switch is disabled.
In the case of site sharing for 1800M and 900M networks, it is better to

Configuration Rule and

transfer the subscribers around the BTS directly to the 1800M network

Adjustment Suggestion

because the signal quality in this network is relatively good when


compared with that (better) in the 1800M network. At this time, it is
required to forcibly transfer traffic.

Change Mode

Offline

Related features

ZGO-02-02-003 Directed-Shift Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.52 Subcell handover aigorithm (HoControl[2]_17)


Full Name

Subcell handover aigorithm

Abbreviation

HoControl[2]_17

3GPP Name

None

3GPP Reference

None
This parameter defines two handover modes of inter-subcell handover
algorithm in the case of high speed: One is based on C/I, and the other

Description

is based on path loss and TA.

Managed Object

Cell

Value Range and Step

Concentric handover,Handover based on path loss and TA


5-366

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

None

Default Value

Concentric handover

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion
Change Mode

The default value is handover based on C/I. It is recommended that the


handover mode be changed to handover based on path loss and TA
because this algorithm is relatively mature.
It is recommended that the handover mode be changed to handover
based on path loss and TA. Currently, this handover algorithm is widely
used for COBCCH handovers on site.
Offline
ZGO-04-02-005 Co-BCCH & ZGO-05-02-009 Concentric Circle Technol-

Related features

ogy

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Subcell parameters

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.53 Allow quality handover in uplink (HoControl[2]_19)


Full Name

Allow quality handover in uplink

Abbreviation

HoControl[2]_19

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow uplink quality handover
in the case of high speed.

Description

It is the 19th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes
5-367

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

Yes

Default Value
Configuration Reason

It is the most common handover type. By default, this function is enabled.

Configuration Rule and


Adjustment Suggestion

Generally, the uplink quality handover is allowed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.54 Allow level handover in uplink (HoControl[2]_20)


Full Name

Allow level handover in uplink

Abbreviation

HoControl[2]_20

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow uplink level handover in the
case of high speed.

Description

It is the 20th bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

5-368
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value
Configuration Reason

It is the most common handover type. By default, this function is enabled.

Configuration Rule and


Adjustment Suggestion

Generally, the uplink level handover is allowed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.55 Allow quality handover in downlink (HoControl[2]_21)


Full Name

Allow quality handover in downlink

Abbreviation

HoControl[2]_21

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow downlink quality handover
in the case of high speed.

Description

It is the 21st bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

It is the most common handover type. By default, this function is enabled.

5-369
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

Generally, the downlink quality handover is allowed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Control
Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.56 Allow level handover in downlink (HoControl[2]_22)


Full Name

Allow level handover in downlink

Abbreviation

HoControl[2]_22

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow downlink level handover
in the case of high speed.

Description

It is the 22nd bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

It is the most common handover type. By default, this function is enabled.

Configuration Rule and


Adjustment Suggestion

Generally, the downlink level handover is allowed.

5-370
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.57 Downlink rapid handover enable (HoControl[2]_23)


Full Name

Downlink rapid handover enable

Abbreviation

HoControl[2]_23

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow downlink rapid handover
in the case of high speed.

Description

It is the 23rd bit in the HoControl field of DWORD type.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

In the high-speed railway scenario, enable this switch. In other

Configuration Reason

scenarios, disable this switch.

5-371
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This handover is mainly applied in the high-speed railway scenario. This


handover algorithm requires that the areas along the railway are covered
Configuration Rule and

by sites in link shape, and the adjacent cells have enough overlapped

Adjustment Suggestion

coverage areas. By configuring adjacent cells with the direction attribute,


it is required to improve the speed of handover judgment and handover
success rate.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Condition
Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.58 C/I Limited Handover Support (HoControl[2]_24)


Full Name

C/I Limited Handover Support

Abbreviation

HoControl[2]_24

3GPP Name

None

3GPP Reference

None
This parameter determines whether to support the handover function of
C/I limited adjacent cells in the case of high speed. Suppose that A is
the serving cell, B and C are the adjacent cells of this serving cell, and B
is the C/I limited adjacent cell of C. If B and C both meet the handover
requirement, and the threshold of C/I limited adjacent cell is also met,
adjacent cell C should be filtered when the adjacent cell is chosen for
handover.
It is the 24th bit in the HoControl field of DWORD type.

Description

Since the version V6.20.21, this parameter is supported.

Managed Object

Cell

5-372
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This parameter is a functional switch, which is disabled by default.


In the turnoff scenario, this function can be enabled for individual cells,
so as to prevent handover to a cross-coverage cell. Generally, this
function should not be configured.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Control
Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.3.4.59 Allow downlink quality rapid handover (HoControl[2]_25)


Full Name

Allow downlink quality rapid handover

Abbreviation

HoControl[2]_25

3GPP Name

None

3GPP Reference

None

5-373
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Some cells have strong interference areas. Therefore, call drop occurs
due to poor downlink quality after handover to these cells is implemented
or a call is connected for a while. To solve this problem, add an algorithm
of downlink rapid quality handover for rescue handover in the case
of high speed. The rapid quality handover depends on the original
measurement value of quality, the adjacent cell does not use windows,
and N value and the N value of handover judgment are shared. Currently,
other handovers are prior to the downlink rapid quality handover.
This parameter determines whether to perform downlink rapid quality
handover.
Description

This parameter is used for TCH handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

This function is enabled only in the cells with poor downlink quality. For

Configuration Reason

common cells, it is not required to enable this function.

Configuration Rule and

Generally, this switch is enabled only when the downlink quality of this

Adjustment Suggestion

cell is poor and meanwhile strong interference exists.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5-374
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.4.60 The load of HO from FR to HR (V3) (FrToAmrHrHoLoadThr)


Full Name

The load of HO from FR to HR (V3)

Abbreviation

FrToAmrHrHoLoadThr

3GPP Name

None

3GPP Reference

None
When the cell load reaches a certain level, handover from FR to HR (V3)
should be initiated, so as to get more channel resources and enhance
system capacity. This parameter determines the load threshold for
initiating handover from FR to HR (V3).
The value of this parameter should be smaller than or equal to the value
of FrHoLoadThr.
The load calculation formula is as follows: Load = Number of busy
channels in the cell x 100 / (Number of busy channels in the cell +

Description

Number of idle channels in the cell).

Managed Object

Cell

Value Range and Step

20..100

Unit

Default Value

80

Default Value
Configuration Reason

When the cell load reaches 80%, the cell is regarded as a busy cell. In
this case, handover from FR to HR (V3) can be performed to enhance
system capacity.
This parameter is valid when the FRTHRHOSupport switch is enabled
in the cell.
The larger the value of this parameter, the higher the cell load for
initiating handover from FR to HR (V3), and therefore the lower the

Configuration Rule and

opportunity.

Adjustment Suggestion

The smaller the value of this parameter, the lower the cell load for
initiating handover from FR to HR (V3), and therefore the higher the
opportunity.
If this parameter is configured too small, number of intra-cell handovers
will increase.

Change Mode

Offline

Related features

ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters

[Cell]FRTHRHOSupport
[Cell]FrToHrHoLoadThr
This parameter is valid only when the FRTHRHOSupport switch is

Relationship

enabled.
FrToHrHoLoadThr >= FrToAmrHrHoLoadThr

Related Interfaces

None

5-375
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.614d

Parameter Modifying
Detail

None

5.3.4.61 The load of HO from FR to HR(V1) (FrToHrHoLoadThr)


Full Name

The load of HO from FR to HR(V1)

Abbreviation

FrToHrHoLoadThr

3GPP Name

None

3GPP Reference

None
When the cell load reaches a certain level, handover from FR to HR (V1)
should be initiated, so as to get more channel resources and enhance
system capacity. This parameter determines the load threshold for
initiating handover from FR to HR (V1).
This parameter value should be larger than or equal to
FrToAmrHrHoLoadThr.
The load calculation formula is as follows: Load = Number of busy
channels in the cell x 100 / (Number of busy channels in the cell +

Description

Number of idle channels in the cell).

Managed Object

Cell

Value Range and Step

20..100

Unit

Default Value

90

Default Value
Configuration Reason

When the cell load reaches 80%, the cell is regarded as a busy cell. In
this case, handover from FR to HR (V1) can be performed to enhance
system capacity.

5-376
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter is valid when the FRTHRHOSupport switch is enabled


in the cell.
The larger the value of this parameter, the higher the cell load for
Configuration Rule and

initiating handover from FR to HR (V1), and therefore the lower the

Adjustment Suggestion

opportunity.
The smaller the value of this parameter, the lower the cell load for
initiating handover from FR to HR (V1), and therefore the higher the
opportunity.

Change Mode

Offline

Related features

ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters

[Cell]FRTHRHOSupport
[Cell]FrToAmrHrHoLoadThr
This parameter is valid only when the FRTHRHOSupport switch is

Relationship

enabled.
FrToHrHoLoadThr >= FrToAmrHrHoLoadThr

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.614d

Parameter Modifying
Detail

None

V1
to FR (HrToFrHoLoadThr)
5.3.4.62 The load of HO from HR
Full Name

The load of HO from HRV1 to FR

Abbreviation

HrToFrHoLoadThr

3GPP Name

None

3GPP Reference

None
This parameter specifies the load threshold for initiating the handover from
HR to FR. When the cell load is less than this parameter value, the handover from HR (V1) from FR is preferred. The handover from HR (V3) to

Description

FR is the second choice.

Managed Object

CELL

5-377
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Value Range and Step

0..100

Unit

Default Value

30

Default Value
Configuration Reason

This parameter balances the subscriber's experience and the channel


load. When the channel load is less than 30, a handover to full-rate
mode can be performed to improve subscriber's experience.
A handover to full-rate mode increases the channel load, which might

Configuration Rule and

exceed the dynamic HR threshold. Therefore, a good balance must be

Adjustment Suggestion

kept between the two thresholds to ensure good subscriber experience


without causing frequent handovers.

Change Mode

Offline

Related features

None

Related Parameters

AmrHrToFrHoLoadThr
For the same cell:

Relationship

AmrHRThs >HrToFrHoLoadThr>= AmrHrToFrHoLoadThr


FrToHrHoLoadThr> HrToFrHoLoadThr

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

V3
to FR (AmrHrToFrHoLoadThr)
5.3.4.63 The load of HO from HR
Full Name

The load of HO from HRV3 to FR

Abbreviation

AmrHrToFrHoLoadThr

3GPP Name

None

3GPP Reference

None
This parameter specifies the load threshold for initiating the handover from
HR (V3) to FR. When the cell load is lower than this parameter value, the

Description

handover from HR (V3) to FR is initiated.


5-378

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

CELL

Value Range and Step

0..100

Unit

Default Value

20

Default Value
Configuration Reason

This parameter balances the subscriber's experience and the channel


load. When the channel load is less than 20, a handover to AMR full rate
can be performed to improve subscriber's experience.
A handover to AMR full-rate mode increases the channel load, which

Configuration Rule and


Adjustment Suggestion

might exceed the dynamic HR threshold. Therefore, a good balance


must be kept between the two thresholds to ensure good subscriber
experience without causing frequent handovers.

Change Mode

Offline

Related features

None

Related Parameters

HrToFrHoLoadThr
For the same cell:

Relationship

AmrHRThs >HrToFrHoLoadThr>= AmrHrToFrHoLoadThr


FrToAmrHrHoLoadThr> AmrHrToFrHoLoadThr

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.4.64 The quality of HO from FR to HR (FrHoQuaThr)


Full Name

The quality of HO from FR to HR

Abbreviation

FrHoQuaThr

3GPP Name

None

3GPP Reference

None

5-379
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

When the cell load reaches a certain level, handover from FR to HR


should be initiated, so as to get more channel resources and enhance
system capacity. However, the quality of the chosen FR call must meet a
certain requirement. This parameter determines the quality threshold for
initiating handover from FR to HR.
The value of this parameter should be smaller than that of HrHoQuaThr
Description

or AmrHrHoQuaThr.

Managed Object

Cell

Value Range and Step

0..69

Unit

None

Default Value

10

Default Value
Configuration Reason

The voice quality must meet a certain requirement after handover from
FR to HR. Therefore, this parameter can be configured to a relatively
small value.

Configuration Rule and


Adjustment Suggestion

The lower the threshold, the higher the requirement on quality.

Change Mode

Offline

Related features

ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters

[Cell]FRTHRHOSupport
[Cell]AmrHrHoQuaThr
[Cell]HrHoQuaThr
This parameter is valid only when the FRTHRHOSupport switch is

Relationship

enabled.
HrHoQuaThr > FrHoQuaThr
AmrHrHoQuaThr > FrHoQuaThr

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.614d

Parameter Modifying
Detail

None

5-380
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.4.65 The quality of HO from HR(V1) to FR (HrHoQuaThr)


Full Name

The quality of HO from HR(V1) to FR

Abbreviation

HrHoQuaThr

3GPP Name

None

3GPP Reference

None
When a HR call can not satisfy the handover demands, and its voice
quality is too bad, HR(V1) to FR handover within one cell will be initiated
to improve the call quality. This parameter is the quality threshold to
initiate HR(V1) to FR handover within one cell.

Description

The value should be greater than FrHoQuaThr.

Managed Object

Cell
8..70

Value Range and Step

Step: 1

Unit

None

Default Value

39

Default Value
Configuration Reason

The voice quality is acceptable if it is higher than this threshold. If it is


less than this threshold, handover should be initiated to improve user
experience.
The larger the parameter value AmrHrHoQuaThr is, the higher is the
tolerability of HR service quality, and the less is the possibility of initiating

Configuration Rule and

HR(V1)-> FR quality handover.

Adjustment Suggestion

The smaller the parameter value AmrHrHoQuaThr is, the lower is the
tolerability of HR service quality, and the less is the possibility of initiating
HR(V1)->FR quality handover.

Change Mode

Offline

Related features

ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters

[Cell]FRTHRHOSupport
[Cell]FrHoQuaThr
Functions of this parameter are valid till the switch FRTHRHOSupport

Relationship

is enabled.
HrHoQuaThr >= FrHoQuaThr

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control
5-381

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

iBSCV6.20.614d

Parameter Modifying
Detail

None

5.3.4.66 The quality of HO from HR(V3) to FR (AmrHrHoQuaThr)


Full Name

The quality of HO from HR(V3) to FR

Abbreviation

AmrHrHoQuaThr

3GPP Name

None

3GPP Reference

None
Although an AMR HR call does not meet handover conditions, the
intra-cell handover from HR (V3) to FR can be initiated to improve voice
quality if the voice quality is too bad. This parameter determines the
quality threshold for initiating the intra-cell handover from HR (V3) to FR.

Description

The value of this parameter should be larger than that of FrHoQuaThr.

Managed Object

Cell

Value Range and Step

20..100

Unit

None

Default Value

39

Default Value
Configuration Reason

The voice quality is acceptable if it is higher than this threshold. If it


is lower than this threshold, handover should be initiated to improve
subscriber experience.
The larger the value of AmrHrHoQuaThr, the higher the tolerance on the
BER of the AMR HR service, and therefore the lower the possibility of

Configuration Rule and

initiating quality handover from HR (V3) to FR.

Adjustment Suggestion

The smaller the value of AmrHrHoQuaThr, the lower the tolerance on


the BER of the AMR HR service, and therefore the higher the possibility
of initiating quality handover from HR (V3) to FR.

Change Mode

Offline

Related features

ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters

[Cell]HRTFRHOSupport
[Cell]FrHoQuaThr
This parameter is valid only when the HRTFRHOSupport switch is

Relationship

enabled.
AmrHrHoQuaThr > FrHoQuaThr

Related Interfaces

None

Impact on Equipment

0
5-382

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.614d

Parameter Modifying
Detail

None

5.3.4.67 P value of load and quality handover (LoadAndQualHoP)


Full Name

P value of load and quality handover

Abbreviation

LoadAndQualHoP

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008
For the handovers between FR and HR caused by load and quality
changes, if P out of the N values (the latest average N values of signal
quality) satisfy the threshold requirements, handover can be initiated.
This parameter value should be smaller than or equal to

Description

LoadAndQualHoN.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value to 3, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.


If the value is too small, it is very easy to satisfy the condition of

Configuration Rule and


Adjustment Suggestion

handover decision, handover is too frequent.


If the value is too large, it is very difficult to satisfy the condition of
handover decision.

Change Mode

Offline

Related features

ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters

[Cell]FRThrHoSupport,
[Cell]LoadAndQualHoN

5-383
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter takes effect until the FR->HR switch based on load is
Relationship

enabled.
This parameter value should be smaller than or equal to
LoadAndQualHoN.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.68 N value of load and quality handover (LoadAndQualHoN)


Full Name

N value of load and quality handover

Abbreviation

LoadAndQualHoN

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008
For the handovers between FR and HR caused by load and quality
changes, if P out of the N values (the latest average N values of signal
quality) satisfy the threshold requirements, handover can be initiated.

Description

This parameter value should be larger than or equal to LoadAndQualHoP.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value to 4, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.


If the value is set too small and samples of handover decision are few,

Configuration Rule and

the handover decision is incorrect.

Adjustment Suggestion

If the value is set too large, it takes a long time to make handover
decisions and call drop occurs easily caused by handover delays.

5-384
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related features

ZGO-03-02-013 Dynamic FR/HR Adjustment

Related Parameters

[Cell]FRThrHoSupport,
[Cell]LoadAndQualHoP
This parameter takes effect until the FR->HR switch based on load is

Relationship

enabled.
This parameter value should be larger than or equal to LoadAndQualHoP.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.69 The priority of the handover from Macro cell to Micro cell (MacroMicroPrio)
Full Name

The priority of the handover from Macro cell to Micro cell

Abbreviation

MacroMicroPrio

3GPP Name

None

3GPP Reference

None
This parameter describes whether the macro-micro handover decision
takes priority over the PBGT handover decision.
If the switch is enabled, the macro-micro handover takes priority;

Description

if the switch is disabled, the PBGT handover takes priority.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

Generally, the macro-micro handover takes priority if it is enabled.

Configuration Reason

Otherwise, it is disabled.

5-385
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

Generally, the macro-micro handover takes priority if it is enabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.4.70 Is Dual-Frequency Traffic Handover Support (DualFreqHoSup)


Full Name

Is Dual-Frequency Traffic Handover Support

Abbreviation

DualFreqHoSup

3GPP Name

None

3GPP Reference

None

Description

Is Dual-Frequency Traffic Handover Support

Managed Object

CELL
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

Traffic handover is normally not enabled for a dual-frequency network.

Configuration Rule and

If a dual-frequency network associated cell is set to carry traffic, enable

Adjustment Suggestion

this function.

Change Mode

Offline
5-386

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.3.4.71 Dual-Frequency Handover Parameter N (DualFreqHoN)


Full Name

Dual-Frequency Handover Parameter N

Abbreviation

DualFreqHoN

3GPP Name

None

3GPP Reference

None

Description

Dual-Frequency Handover Parameter N

Managed Object

CELL

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason

Ensure the stability and reliability of the handover decision.

Configuration Rule and


Adjustment Suggestion

To speed up the handover decision, reduce the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None
5-387

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.3.4.72 Dual-Frequency Handover Parameter P (DualFreqHoP)


Full Name

Dual-Frequency Handover Parameter P

Abbreviation

DualFreqHoP

3GPP Name

None

3GPP Reference

None

Description

Dual-Frequency Handover Parameter P

Managed Object

CELL

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason

Ensure the stability and reliability of the handover decision.

Configuration Rule and


Adjustment Suggestion

To speed up the handover decision, reduce the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-388
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.3.4.73 Dual-Frequency Handover TA Threshold (DualFreqHoTAThs)


Full Name

Dual-Frequency Handover TA Threshold

Abbreviation

DualFreqHoTAThs

3GPP Name

None

3GPP Reference

None

Description

Dual-Frequency Handover TA Threshold

Managed Object

CELL
[0..63]

Value Range and Step

Step: 1

Unit

None

Default Value

63

Default Value

The associated cells of two dual-frequency networks have similar

Configuration Reason

coverage.

Configuration Rule and

If the dual-frequency network associated cell has a coverage smaller

Adjustment Suggestion

than the local cell, reduce this threshold.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID->Handover


Control->Handover Control

5-389
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.3.4.74 Dual-Frequency Handover RxLevel Threshold (DualFreqHoDLThs)


Full Name

Dual-Frequency Handover RxLevel Threshold

Abbreviation

DualFreqHoDLThs

3GPP Name

None

3GPP Reference

None

Description

Dual-Frequency Handover RxLevel Threshold

Managed Object

CELL
[0..63]

Value Range and Step

Step: 1

Unit

None

Default Value

30

Default Value
Configuration Reason

The default level can ensure the normal services of a cell.

Configuration Rule and

If the service quality is still poor after the service is handed over to

Adjustment Suggestion

subcell 1, this threshold can be increased.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New
5-390

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.4.75 Dual-Frequency Traffic Handover Threshold (DualFreqOverLoadThs)


Full Name

Dual-Frequency Traffic Handover Threshold

Abbreviation

DualFreqOverLoadThs

3GPP Name

None

3GPP Reference

None
If an associated cell is set, the dual-frequency network handover decision
is performed when the cell load is greater than the dual-frequency-network
traffic handover threshold and the associated cell load is less than the

Description

same handover threshold.

Managed Object

CELL

Value Range and Step

0~100

Unit

Default Value

70

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

DualFreqNetTchThs

Relationship

DualFreqNetTchThs< DualFreqOverLoadThs

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site config->Site ID->Cell ID->Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.713a

Parameter Modifying
Detail

NEW

5-391
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.5 Other Parameters


5.3.5.1 Penalty time for handover failure (HoFailPenalTime)
Full Name

Penalty time for handover failure

Abbreviation

HoFailPenalTime

3GPP Name

Internal

3GPP Reference

None
This parameter defines the penalty time for destination cell if MS fails
to handover to the destination cell or channel allocation fails during handover. During the penalty time, this parameter is used to perform an offset

Description

on the level of this cell. This parameter determines penality duration.

Managed Object

Cell
1..255

Value Range and Step

Step: 1

Unit

Measurement report period

Default Value

Default Value
Configuration Reason

The default value is in accordance with the preprocessed value. If the


preprocessed value 2, the penalty time is about 7 seconds which is
enough for the change of radio environment.

Configuration Rule and

The default value is on the basis of the preprocessed value. It should be

Adjustment Suggestion

adjusted to a larger value if the preprocessed value is unavailable.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-392
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.5.2 Difference of dynamic priority (DynPrioOffset)


Full Name

Difference of dynamic priority

Abbreviation

DynPrioOffset

3GPP Name

None

3GPP Reference

None
This parameter indicates the tolerable difference of dynamic handover
priority.
During handover, if the first cells dynamic handover priority is higher than
that of the second cell but the second cell is in MS moving direction, then
the direction-based handover algorithm works if the difference between
the two cells handover priorities is within the tolerable difference. MS is

Description

handover to the second cell.

Managed Object

Cell
1..7

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

This parameter is to handover the adjacent cell priority. The smaller the
value is, it is easier for the cell with good quality signal to take priority. It
is proper to set the default value as 1.
This parameter affects the priority of the candidate cell. The larger this
parameter is, the greater the priority difference between to dynamic cells
should be, so as to change the priority of two cells.

Change Mode

Offline

Related features

ZGO-02-02-002 Dynamic Handover Priority Algorithm

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

None

5-393
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.3.5.3 PBGT difference (PbgtOffset)


Full Name

PBGT difference

Abbreviation

PbgtOffset

3GPP Name

None

3GPP Reference

None
This parameter defines a tolerable PBGT difference.During handover, if
the first cells PBGT is higher than that of the second cell but the second
cell is in MS moving direction, then the direction-based handover algorithm works if the difference between the two cells PBGTs is within the
tolerable difference. MS is handover to the second cell. This parameter

Description

indicates this allowable difference.

Managed Object

Cell
0..20

Value Range and Step

Step: 1

Unit

dB

Default Value

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

This parameter is to handover the adjacent cell priority. The smaller the
value is, it is easier for the cell with good quality signal to take priority. It
is proper to set the default value as 3.
This parameter affects the priority of the candidate cell. The larger this
parameter is, the greater the power budget difference between two cells
should be, so as to change the priority of two cells.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-394
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.5.4 Same layer permitted on traffic HO (TrafficHoLayerCtl_0)


Full Name

Same layer permitted on traffic HO

Abbreviation

TrafficHoLayerCtl_0

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether a neighbor cell of the same layer can

Description

be considered as a target cell during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

Usually, traffic handover occurs at the same layer or the lower layer, so

Configuration Reason

as to save the resources at the upper layer.

Configuration Rule and

According to the layered network configuration on site, select the

Adjustment Suggestion

destination layer of traffic handover to alleviate congestion.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

5-395
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.3.5.5 Upper layer permitted on traffic HO (TrafficHoLayerCtl_1)


Full Name

Upper layer permitted on traffic HO

Abbreviation

TrafficHoLayerCtl_1

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether a neighbor cell of the upper layer can

Description

be considered as a target cell during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

Usually, traffic handover occurs at the same layer or the lower layer, so

Configuration Reason

as to save the resources at the upper layer.

Configuration Rule and

According to the layered network configuration on site, select the

Adjustment Suggestion

destination layer of traffic handover to alleviate congestion.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.710

5-396
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

New

5.3.5.6 Lower layer permitted on traffic HO (TrafficHoLayerCtl_2)


Full Name

Lower layer permitted on traffic HO

Abbreviation

TrafficHoLayerCtl_2

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether a neighbor cell of the lower layer can

Description

be considered as a target cell during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

Usually, traffic handover occurs at the same layer or the lower layer, so

Configuration Reason

as to save the resources at the upper layer.

Configuration Rule and

According to the layered network configuration on site, select the

Adjustment Suggestion

destination layer of traffic handover to alleviate congestion.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-397
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.5.7 Undefinde layer permitted on traffic HO (TrafficHoLayerCtl_3)


Full Name

Undefinde layer permitted on traffic HO

Abbreviation

TrafficHoLayerCtl_3

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether a neighbor cell of the unknown layer

Description

can be considered as a target cell during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No
Usually, traffic handover occurs at the same layer or the lower layer,

Default Value

so as to save the resources at the upper layer. The undefined layer is

Configuration Reason

applied in a non-layered network. If necessary, configure it to function as


the target layer for traffic handover.

Configuration Rule and

According to the layered network configuration on site, select the

Adjustment Suggestion

destination layer of traffic handover to alleviate congestion.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-398
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.5.8 GSM900 frequency band P-GSM permitted on traffic HO (TrafficHoFreqCtl_0)


Full Name

GSM900 frequency band P-GSM permitted on traffic HO

Abbreviation

TrafficHoFreqCtl_0

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether a neighbor cell with the basic
GSM900 baseband P-GSM (ARFCN = 1-124) can be considered as a

Description

target cell during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

In most cases, the GSM900 is applied in target cells during traffic

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

According to the frequency band used in the on-site network, configure


the destination frequency band used during traffic handover, so as to
alleviate congestion.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-399
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.5.9 EXT900 frequency band E-GSM permitted on traffic HO (TrafficHoFreqCtl_1)


Full Name

EXT900 frequency band E-GSM permitted on traffic HO

Abbreviation

TrafficHoFreqCtl_1

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether a neighbor cell with the basic
GSM900 baseband E-GSM (ARFCN = 0-124, 975-1023) can be consid-

Description

ered as a target cell during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

In few cases, the E-GSM is applied in target cells during traffic handover.
According to the frequency band used in the on-site network, configure
the destination frequency band used during traffic handover, so as to
alleviate congestion.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-400
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.5.10 DCS1800 frequency band permitted on traffic HO (TrafficHoFreqCtl_2)


Full Name

DCS1800 frequency band permitted on traffic HO

Abbreviation

TrafficHoFreqCtl_2

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether a neighbor cell with the basic
DCS1800 baseband DCS1800 (ARFCN = 512-885) can be considered

Description

as a target cell during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

In few cases, the DCS1800 is applied in target cells during traffic

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

According to the frequency band used in the on-site network, configure


the destination frequency band used during traffic handover, so as to
alleviate congestion.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-401
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.5.11 PCS1900 frequency band permitted on traffic HO (TrafficHoFreqCtl_4)


Full Name

PCS1900 frequency band permitted on traffic HO

Abbreviation

TrafficHoFreqCtl_4

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether a neighbor cell with the basic
PCS1900 baseband PCS1900 (ARFCN = 512-810) can be considered

Description

as a target cell during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

In few cases, the GSM1900 is applied in target cells during traffic

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

According to the frequency band used in the on-site network, configure


the destination frequency band used during traffic handover, so as to
alleviate congestion.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-402
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.5.12 GSM850 frequency band permitted on traffic HO (TrafficHoFreqCtl_5)


Full Name

GSM850 frequency band permitted on traffic HO

Abbreviation

TrafficHoFreqCtl_5

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether a neighbor cell with the basic
GSM850 baseband GSM850 (ARFCN = 128-251) can be considered as

Description

a target cell during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

In few cases, the GSM850 is applied in target cells during traffic

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

According to the frequency band used in the on-site network, configure


the destination frequency band used during traffic handover, so as to
alleviate congestion.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-403
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.5.13 Prefer layer for traffic handover (TrafficHoPreferLayer)


Full Name

Prefer layer for traffic handover

Abbreviation

TrafficHoPreferLayer

3GPP Name

Internal Defination

3GPP Reference

None

Description

This parameter determines the preferred layer during traffic handover.

Managed Object

Cell
0: Preferred when the adjacent cell and the local cell are on the same
layer.
1: Preferred when the adjacent cell is on the upper layer of the lcoal cell.
2: Preferred when the adjacent cell is on the lower layer of the local cell.
3: Preferred when the adjacent cell is on an undefined layer.

Value Range and Step

0XFF: No preferred layer

Unit

None

Default Value

0XFF

Default Value

The preferred layer and value are configured according to the network

Configuration Reason

condition. By default, this function is disabled.


It is required to configure a preferred layer during traffic handover

Configuration Rule and

according to the network condition. Usually, the system is prior to switch

Adjustment Suggestion

the traffic to the layer with low traffic. In most cases, the layer is a lower
layer or same layer for absorbing traffic.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-404
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.5.14 PBGT offset of prefer layer for traffic handover (TrafficHoLayerOffset)


Full Name

PBGT offset of prefer layer for traffic handover

Abbreviation

TrafficHoLayerOffset

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the specific value for the preferred layer during

Description

traffic handover.

Managed Object

Cell

Value Range and Step

0..48,means -24dB..24dB

Unit

dB

Default Value

24

Default Value

The preferred layer and value are configured according to the network

Configuration Reason

condition. By default, this function is disabled.


The PBGT offset reflects the priority of the preferred layer. When the

Configuration Rule and


Adjustment Suggestion

system sorts the cells that meet the threshold of traffic handover, the
cells with larger offset will be ranked top. However, the offset must not
be configured excessively high. Otherwise, the traffic may be switched
to the cells with poor signal quality.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-405
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.5.15 Prefer band for traffic handover (TrafficHoPreferBand)


Full Name

Prefer band for traffic handover

Abbreviation

TrafficHoPreferBand

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the preferred frequency band during traffic

Description

handover.

Managed Object

Cell
0: Preferred when the adjacent cell and the local cell are on the same
layer.
1: Preferred when the adjacent cell is on the upper layer of the lcoal cell.
2: Preferred when the adjacent cell is on the lower layer of the local cell.
3: Preferred when the adjacent cell is on an undefined layer.

Value Range and Step

0XFF: No preferred layer

Unit

None

Default Value

0XFF

Default Value

The preferred frequency band and value are configured according to the

Configuration Reason

network condition. By default, this function is disabled.


It is required to configure a preferred layer during traffic handover

Configuration Rule and

according to the network condition. Usually, the system is prior to switch

Adjustment Suggestion

the traffic to the layer with low traffic. In most cases, the layer is a lower
layer or same layer for absorbing traffic.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-406
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.5.16 PBGT offset of prefer band for traffic handover (TrafficHoBandOffset)


Full Name

PBGT offset of prefer band for traffic handover

Abbreviation

TrafficHoBandOffset

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the specific value for the preferred frequency

Description

band during traffic handover.

Managed Object

Cell

Value Range and Step

0..48,means -24dB..24dB

Unit

dB

Default Value

24

Default Value

The preferred frequency band and value are configured according to the

Configuration Reason

network condition. By default, this function is disabled.


The PBGT offset reflects the priority of the preferred frequency band.

Configuration Rule and


Adjustment Suggestion

When the system sorts the cells that meet the threshold of traffic
handover, the cells with larger offset will be ranked top. However, the
offset must not be configured excessively high. Otherwise, the traffic
may be switched to the cells with poor signal quality.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-407
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.3.5.17 Threshold of traffic for handover (TrafficThs)


Full Name

Threshold of traffic for handover

Abbreviation

TrafficThs

3GPP Name

Internal

3GPP Reference

None
If TCH occupation rate of a cell is greater than this parameter value (number of occupied TCH channels / number of total TCH channels, not including blocked idle channels), then it indicates the cell is too busy, and traffic

Description

handover is triggered for the cell.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

Default Value

80

Default Value

It is proper to initiate congestion control when the cell load reaches 80%

Configuration Reason

and a few channels are available and.

Configuration Rule and


Adjustment Suggestion

For the cell with fewer channels, channel congestion occurs easily
caused by the burst services, so this parameter can be set as relatively
small.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-408
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.5.18 Lag time for PBGT between different layers (PbgtHoParam_0)


Full Name

Lag time for PBGT between different layers

Abbreviation

PbgtHoParam_0

3GPP Name

None

3GPP Reference

None
To more effectively control traffic distribution in the cell at different layers,
while doing PBGT decision, add PBGT decision offset level (the PBGT
decision offset level of the uplink and downlink is 24 by default) in the
cell at different layers within certain duration, which is lag time for PBGT
between different layers.
Start condition: If MS performs one handover between different layers,
start this timer.
Timeout handling: When it is notified to make handover decision, if the

Description

hadover is PBGT handover, layer offset should not be added.

Managed Object

Cell
0..300

Value Range and Step

Step: 1

Unit

Default Value

50

Default Value

Usually, the default value is 50 s. It is better to add offset to PBGT

Configuration Reason

handover between different layers.

Configuration Rule and


Adjustment Suggestion

The value will be modified to the default value (50 s) if it is 0.If the
lag time is not timed out, it is necessary to add offset to the PBGT
cross-layer handover.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

None
5-409

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.3.5.19 Level offset for PBGT to up layer (PbgtHoParam_1)


Full Name

Level offset for PBGT to up layer

Abbreviation

PbgtHoParam_1

3GPP Name

None

3GPP Reference

None
To more effectively control traffic distribution in the cell at different layers,
while doing PBGT decision, add PBGT decision offset level in the cell at
upper layer within certain duration which is dependent upon the lag time

Description

for handover between different layers.

Managed Object

Cell
0 .. 48corresponds to -24 dbm..24 dbm

Value Range and Step

Step: 1

Unit

None

Default Value

24

Default Value
Configuration Reason

The default is not offset.


The value 0..48 represents -24 db + 24 db. Its effect is the same as
that of PBGT Margin. That is, a lag value between different layers is
added on the basis of PBGT Margin, so as to make PBGT handover
faster/more frequent or slower/less frequent.

Configuration Rule and

It is better to handover to the lower layer as soon as possible and

Adjustment Suggestion

maintain intra-layer handover at the lower layer. PBGT handover is not


initiated to the upper layer unless upper layer signal is always strong.
The large value is useful for traffic balance and congestion alleviation.
Whereas, it makes PBGT handover to the upper layer difficult and
influences the converage rate.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

5-410
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.5.20 Level offset for PBGT to low layer (PbgtHoParam_2)


Full Name

Level offset for PBGT to low layer

Abbreviation

PbgtHoParam_2

3GPP Name

None

3GPP Reference

None
To more effectively control traffic distribution in the cell at different layers,
while doing PBGT decision, add PBGT decision offset level in the cell at
lower layer within certain duration which is dependent upon the lag time

Description

for handover between different layers.

Managed Object

Cell
0 .. 48corresponds to -24 dbm..24 dbm

Value Range and Step

Step: 1

Unit

None

Default Value

24

Default Value
Configuration Reason

The default is not offset.


The value 0..48 represents -24 db + 24 db. Its effect is the same as
that of PBGT Margin. That is, a lag value between different layers is
added on the basis of PBGT Margin, so as to make PBGT handover

Configuration Rule and


Adjustment Suggestion

faster/more frequent or slower/less frequent.


It is better to handover to the lower layer as soon as possible and
maintain intra-layer handover at the lower layer. PBGT handover is not
initiated to the upper layer unless upper layer signal is always strong.
The small value is useful for traffic balance, congestion alleviation, and
PBGT handover to the lower layer, but influences the coverage rate.

Change Mode

Offline

Related features

None

5-411
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Other parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.5.21 The threshold for starting PBGT handover (PbgtHoStartThs)


Full Name

The threshold for starting PBGT handover

Abbreviation

PbgtHoStartThs

3GPP Name

None

3GPP Reference

None
When the current cell's downlink level is less than the start level threshold

Description

for PBGT handover, the PBGT handover decision is performed.

Managed Object

Cell
0 .. 63corresponds to -110 dbm..-47 dbm

Value Range and Step

Step: 1

Unit

dbm

Default Value

45

Default Value

Generally, it is unnecessary to initiate PBGT handover due to the signal

Configuration Reason

is considered as good when the default value is -65 dBm.

5-412
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

If the value is large, it is easy to initiate PBGT handover. If the value is


small, it is difficult to initiate PBGT handover.
The value should be large when it is necessary to share traffic.
Otherwise, it is difficult to share traffic and the congestion rate is
Configuration Rule and

influenced.

Adjustment Suggestion

When it is unnecessary to share traffic, the value can be set to a


relatively small value, which reduces the number of unnecessary
handovers but affects the coverage rate.
It is recommended to set the value of the 900 M cell to the largest in the
900 M and 1800 M dual-frequency network.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.5.22 Handover from macro to micro (MacroMicroStartThs)


Full Name

Handover from macro to micro

Abbreviation

MacroMicroStartThs

3GPP Name

None

3GPP Reference

None
When the current cell's downlink level is less than or equal to the start level
threshold for macro-micro handover, the macro-micro handover decision

Description

is performed.

Managed Object

Cell

5-413
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0 .. 63corresponds to -110 dbm..-47 dbm


Value Range and Step

Step: 1

Unit

dbm

Default Value

40

Default Value

Generally, it is unnecessary to initiate macro-micro handover due to the

Configuration Reason

signal is considered as good when the default value is -70 dBm.


Initially, it is recommended to set this parameter as the largest, so that
the 1800 M cell can absorb more traffic. The larger this parameter

Configuration Rule and

is, it is more likely for the macro-micro handover to occur, and it is

Adjustment Suggestion

easier for traffic to be transferred to the 1800 cell. Adjustment of this


parameter depends on the current condition and subsequent plan of
traffic distribution of the 900 cell and 1800 cell.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

This parameter is valid unless the macro-micro switch hocontrol_13is


enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.5.23 Hysteresis timer when traffic handover (TrafficHysteresisTm)


Full Name

Hysteresis timer when traffic handover

Abbreviation

TrafficHysteresisTm

3GPP Name

None

3GPP Reference

None

5-414
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

When there are many traffic handovers initiated in the current cell, the
interval between two traffic handovers must be larger than the hysteresis
Description

time specified by this parameter.

Managed Object

Cell
0 .. 255

Value Range and Step

Step: 1

Unit

Default Value

Default Value
Configuration Reason

This parameter is invalid in this version and the default is reserved.

Configuration Rule and


Adjustment Suggestion

This parameter is invalid in this version and the default is reserved.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Other parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.5.24 Measure BCCH when in subcell2 (Subcell2MeasureBcch)


Full Name

Measure BCCH when in subcell2

Abbreviation

Subcell2MeasureBcch

3GPP Name

Internal Defination

3GPP Reference

None

5-415
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If this parameter is configured to "Yes", the system adds a BCCH frequency point for broadcasting this cell in the SACCH system message
of the second subcell. After the MS reports measurement reports, the
system collects statistics on the sampling distribution of level difference
between the first subcell and the second subcell. If the MR function is
Description

enabled, the system reports the level difference in the MR.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

1: Yes

Default Value

Enable this function according to operator requirements or network

Configuration Reason

optimization requirements.

Configuration Rule and

Enable this function according to operator requirements or network

Adjustment Suggestion

optimization requirements.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.3.5.25 Back to Source Cell when PBGT Handover (PBGTHoBacktoSource)


Full Name

Back to Source Cell when PBGT Handover

Abbreviation

PBGTHoBacktoSource

3GPP Name

None

3GPP Reference

None
5-416

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter decides whether to set a requirement on the handover


access level for a PBGT handover. If the requirement is set and the MS
does not meet the required level, the PHY Info is not sent, and the MS
Description

handover fails and returns to the source channel.

Managed Object

CELL

Value Range and Step

0~1

Unit

None

Default Value

Default Value
Configuration Reason

Not enabled

Configuration Rule and

To enable the PBGT handover back function on the TCH, enable the

Adjustment Suggestion

function.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Other parameters
Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

5.3.5.26 Back to Source Cell when Other Handover (OtherHoBacktoSource)


Full Name

Back to Source Cell when Other Handover

Abbreviation

OtherHoBacktoSource

3GPP Name

None

3GPP Reference

None

5-417
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter decides whether to set a requirement on the handover


access level for a non-PBGT handover. If the requirement is set and the
MS does not meet the required level, the PHY Info is not sent, and the
Description

MS handover fails and returns to the source channel.

Managed Object

CELL

Value Range and Step

0~1

Unit

None

Default Value

Default Value
Configuration Reason

Not enabled

Configuration Rule and

To enable the Non-PBGT handover back function on the TCH, enable

Adjustment Suggestion

the function.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Other parameters
Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

5.3.5.27 HoAccess Require Rxlevel offset (HoAccessReqLevOffset)


Full Name

HoAccess Require Rxlevel offset

Abbreviation

HoAccessReqLevOffset

3GPP Name

None

3GPP Reference

None

5-418
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter calculates the level offset relative to the level required by
the handover detection. The value is calculated using the formula: 110Description

TargetAverageRxLevel + LinkBalance + (HoAccessReqLevOffset -35)

Managed Object

CELL
0..70

Value Range and Step

If the parameter is set to 35, the corresponding level offset is 1 dBm.

Unit

None

Default Value

45

Default Value
Configuration Reason

The default offset is 11db.

Configuration Rule and

Set a higher value when it is hoped to lower the requirement for

Adjustment Suggestion

handover detect level.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Other parameters
Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

5.3.5.28 HoAccess Require Rxlevel Select Strategy when Other Handover


(OtherHoAccessLevSel)
Full Name

HoAccess Require Rxlevel Select Strategy when Other Handover

Abbreviation

OtherHoAccessLevSel

3GPP Name

None

3GPP Reference

None

5-419
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter decides the level request selection strategy during handover detection for a non-PBGT request. The options include the minimum access level or the value calculated by the formula (110- TargetAverDescription

ageRxLevel + LinkBalance + (HoAccessReqLevOffset -35)).

Managed Object

CELL
1~2
1: Expected uplink level

Value Range and Step

2: Minimum allowed access level

Unit

None

Default Value

Default Value
Configuration Reason

Strategy 1

Configuration Rule and

If SD related indexes degrade when the handover back is performed

Adjustment Suggestion

according to strategy 1, change to strategy 2.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Other parameters

Parameter Modifying
Version

iBSCV6.20.713b

Parameter Modifying
Detail

NEW

5.3.6 Handover Arithmetic Parameters


5.3.6.1 Traffic handover threshold (TrafficLevThs)
Full Name

Traffic handover threshold

Abbreviation

TrafficLevThs

5-420
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

None

3GPP Reference

None
This parameter is used for traffic handover. For the original handover
condition that adjacent cells level must be higher than that of this cell,
modify it so that adjacent cells level must be higher than this threshold.In
this way, traffic handover can be improved greatly. This threshold must
be less than the PBGT threshold in reverse direction. Otherwise, it may

Description

result in toggle handover.

Managed Object

Cell
0 .. 48

Value Range and Step

Step: 1

Unit

None

Default Value

24

Default Value

Traffic handover is to balance the traffic, which depends upon the level

Configuration Reason

of the destination cell not less than that of the serving cell.
This parameter is valid after automatic handover based on traffic
(HoControl6) is allowed.Note that the threshold of PBGT handover
in the reverse direction of the destination cell needs to be raised for

Configuration Rule and


Adjustment Suggestion

compensation.
Under the dense traffic scenario, the smaller this parameter is, the
stronger the capability of absorbing traffic of the destination Nclayer
cell or frequency band cell is, the easier the traffic can be handed out
(the traffic threshold shall be reached), which helps alleviate the TCH
channel congestion of the cell.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Arithmetic

Parameter Modifying
Version

None

5-421
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.3.6.2 Level offset during penalty (PenaltyLevOffset)


Full Name

Level offset during penalty

Abbreviation

PenaltyLevOffset

3GPP Name

None

3GPP Reference

None
This parameter is used to perform an offset on the downlink level of this

Description

cell in the penalty period.

Managed Object

Cell
0 .. 63

Value Range and Step

Step: 1

Unit

dB

Default Value

15

Default Value
Configuration Reason

15dBUsually, 15 dB penalty can ensure no more handover to the cell.


The system allows three times handover failure to a certain destination
cell. When the second or third handover decision is made, an offset is

Configuration Rule and


Adjustment Suggestion

manually performed on the level of the destination cell to which handover


fails for the first time. If the destination cell still takes the first priority
compared with other adjacent cells after its level is reduced manually,
go on initiating handover to it. After the attempt fails for three times,
shield it in the penalty period.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Arithmetic

5-422
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.6.3 Uplink interference quality offset (QOffSetUl)


Full Name

Uplink interference quality offset

Abbreviation

QOffSetUl

3GPP Name

None

3GPP Reference

None
When handover occurs in the cell, BSC judges whether interference
occurs to the channel through checking the relation between level and
quality.
Handover requirements are satisfied, when P times in N
times measurement of IntraHoUlLevN satisfies the formula
rxqual-ulFQSS(RXLEV_UL+SOffSetUl). Where, rxqual-ul is uplink
quality, QOffSetUL is uplink quality offset, AvRxlevUL(n) is uplink level,
SOffSetUL is uplink level offset, and FQSS is the current quality offset
confirmed by the level and corresponding level offset"SOffSetUl". The
specific algorithm is:
InterFQSS=
255 AvRxlevUL(n) < SOffSetUL + 20
| QOffSetUl + 4 SOffSetUL + 20 AvRxlevUL(n) < SOffSetUL + 30
| QOffSetUl + 3 SOffSetUL + 30 AvRxlevUL(n) < SOffSetUL + 40
QOffSetUl + 2 SOffSetUL + 40 AvRxlevUL(n)
After interference is confirmed, when channels are requested, with
status of the original channel occupied, from the database to process
services, the database selects proper channels based on the original

Description

channel status.

Managed Object

Cell
0..20

Value Range and Step

Step: 1

Unit

None

Default Value

10

Default Value

Setting of the default value is in accordance with the common uplink

Configuration Reason

interference environment.

Configuration Rule and


Adjustment Suggestion

The larger the value is, the higher the quality tolerability under the
corresponding level is, and it is more difficult to initiate quality handover
which should be adjusted in accordance with the actual network situation.
5-423

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Arithmetic
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.6.4 Uplink interference level offset (SOffSetUl)


Full Name

Uplink interference level offset

Abbreviation

SOffSetUl

3GPP Name

None

3GPP Reference

None
When handover occurs in the cell, BSC judges whether interference
occurs to the channel through checking the relation between level and
quality.
Handover requirements are satisfied, when P times in N
times measurement of IntraHoUlLevN satisfies the formula
rxqual-ulFQSS(RXLEV_UL+SOffSetUl). Where, rxqual-ul is uplink
quality, QOffSetUL is uplink quality offset, AvRxlevUL(n) is uplink level,
SOffSetUL is uplink level offset, and FQSS is the current quality offset
confirmed by the level and corresponding level offset"SOffSetUl". The
specific algorithm is:
InterFQSS=
255 AvRxlevUL(n) < SOffSetUL + 20
| QOffSetUl + 4 SOffSetUL + 20 AvRxlevUL(n) < SOffSetUL + 30
| QOffSetUl + 3 SOffSetUL + 30 AvRxlevUL(n) < SOffSetUL + 40

Description

QOffSetUl + 2 SOffSetUL + 40 AvRxlevUL(n)

5-424
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

After interference is confirmed, when channels are requested, with


status of the original channel occupied, from the database to process
services, the database selects proper channels based on the original
channel status.
Managed Object

Cell
0..20

Value Range and Step

Step: 1

Unit

None

Default Value

15

Default Value

Setting of the default value is in accordance with the common uplink

Configuration Reason

interference environment.

Configuration Rule and


Adjustment Suggestion

The larger the value is, the higher the requirement on quality handover
is, and it is more difficult to initiate quality handover which should be
adjusted in accordance with the actual network situation.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Arithmetic
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.6.5 Downlink interference quality offset (QOffSetDl)


Full Name

Downlink interference quality offset

Abbreviation

QOffSetDl

3GPP Name

None

3GPP Reference

None

5-425
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

When handover occurs in the cell, BSC judges whether interference


occurs to the channel through checking the relation between level and
quality.
Handover requirements are satisfied, when P times in N
times measurement of IntraHoUlLevN satisfies the formula
rxqual-ulFQSS(RXLEV_UL+SOffSetUl). Where, rxqual-dl is downlink
quality, QOffSetDL is uplink quality offset, RXLEV_DL is downlink level,
SOffSetDL is downlink level offset, and FQSS is the current quality offset
confirmed by the level and corresponding level offset"SOffSetDl". The
specific algorithm is:
InterFQSS=
255 AvRxlevUL(n) < SOffSetUL + 20
| QOffSetUl + 4 SOffSetUL + 20 AvRxlevUL(n) < SOffSetUL + 30
| QOffSetUl + 3 SOffSetUL + 30 AvRxlevUL(n) < SOffSetUL + 40
QOffSetUl + 2 SOffSetUL + 40 AvRxlevUL(n)
After interference is confirmed, when channels are requested, with
status of the original channel occupied, from the database to process
services, the database selects proper channels based on the original
Description

channel status.

Managed Object

Cell
0..20

Value Range and Step

Step: 1

Unit

None

Default Value

10

Default Value

Setting of the default value is in accordance with the common downlink

Configuration Reason

interference environment.

Configuration Rule and


Adjustment Suggestion

The larger the value is, the higher the quality tolerability under the
corresponding level is, and it is more difficult to initiate quality handover
which should be adjusted in accordance with the actual network situation.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-426
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Arithmetic

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.6.6 Downlink interference level offset (SOffSetDl)


Full Name

Downlink interference level offset

Abbreviation

SOffSetDl

3GPP Name

None

3GPP Reference

None
When handover occurs in the cell, BSC judges whether interference
occurs to the channel through checking the relation between level and
quality.
Handover requirements are satisfied, when P times in N
times measurement of IntraHoUlLevN satisfies the formula
rxqual-ulFQSS(RXLEV_UL+SOffSetUl). Where, rxqual-dl is downlink
quality, QOffSetDL is uplink quality offset, XLEV_DL is downlink level,
SOffSetDL is downlink level offset, and FQSS is the current quality offset
confirmed by the level and corresponding level offset"SOffSetDl". The
specific algorithm is:
InterFQSS=
255 AvRxlevUL(n) < SOffSetUL + 20
| QOffSetUl + 4 SOffSetUL + 20 AvRxlevUL(n) < SOffSetUL + 30
| QOffSetUl + 3 SOffSetUL + 30 AvRxlevUL(n) < SOffSetUL + 40
QOffSetUl + 2 SOffSetUL + 40 AvRxlevUL(n)
After interference is confirmed, when channels are requested, with
status of the original channel occupied, from the database to process
services, the database selects proper channels based on the original

Description

channel status.

Managed Object

Cell
0..20

Value Range and Step

Step: 1

Unit

None

Default Value

10

Default Value

Setting of the default value is in accordance with the common downlink

Configuration Reason

interference environment.
5-427

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

The larger the value is, the higher the requirement on quality handover
is, and it is more difficult to initiate quality handover which should be
adjusted in accordance with the actual network situation.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Arithmetic

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.6.7 Penalty time for handover caused by interference (InterfHoPenalTime)


Full Name

Penalty time for handover caused by interference

Abbreviation

InterfHoPenalTime

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the penalty time of the interference handover
in a cell, including the penalty for handover failure and continuous intra-

Description

cell handovers.

Managed Object

Cell

Value Range and Step

1..255

Unit

measurement report period

Default Value

7
If the pre-processed measurement reports are used for pre-processing,

Default Value

this parameter is configured to 7. In this case, the penalty time is long

Configuration Reason

enough. If common measurement reports are used, the value of this


parameter should be configured to a larger value.

5-428
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

It is required to configure this parameter by considering the period of


Configuration Rule and
Adjustment Suggestion

pre-processing measurement reports. If this parameter is configured to


a small value, failed or invalid handovers may continuously occur. If this
parameter is configured to a larger value, the intra-cell handover may
not be implemented in time.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Arithmetic

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.3.6.8 Interference band requirement for intracell handover caused by interference


(InterfBandforHo)
Interference band requirement for intracell handover caused by interferFull Name

ence

Abbreviation

InterfBandforHo

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines the maximum interference band required by
the intra-cell interference handover. If a channel does not meet this interference band (the value of interference band is not larger than the value

Description

of this parameter), the intra-cell handover cannot be implemented.

Managed Object

Cell

Value Range and Step

1..5

Unit

None

Default Value

5-429
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

If the value of interference band is not larger than 2, it indicates that the
interference in this channel is small enough. In this case, the channel
can be used for intra-cell interference handover.
Usually, the value of this parameter is not modified. If this parameter is

Configuration Rule and

configured to a large value, the handover success rate will be affected.

Adjustment Suggestion

If this parameter is configured to a small value, no channel is allocated


during intra-cell handover.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Arithmetic
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.3.6.9 Invalid intra-handover time (TMaxiHo)


Full Name

Invalid intra-handover time

Abbreviation

TMaxiHo

3GPP Name

None

3GPP Reference

None
If MS performs handover continuously in the cell, it indicates great
interference in this position and no appropriate channel is available.
In such a case, MS shall be forbidden to perform handover within a
certain time. The judgment method is as follows: If handover occurs
within the invalid intra-handover time, then the previous handover is
considered to have no influence on interference, the counter HoCount
increases by 1 and restart TMaxIHo. If handover occurs after the invalid
intra-handover time, the previous handover is considered valid and clear

Description

the counter to 0.

5-430
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

If the counter value reaches the value of MAX count of invalid


intra-handover parameter, then it indicates not to attempt handover
within a certain period. Perform penalty in intra-cell penalty mode.
Managed Object

Cell
0..255

Value Range and Step

Step: 1

Unit

Measurement report period or pre-processing measurement report period

Default Value

16

Default Value

Usually, if the handover occurs continuously within 16 measurement

Configuration Reason

reports (or preprocessing reports), it is considered as too frequent.


If the time is adjusted as too short, the invalid handover is easily to be

Configuration Rule and

judged as valid handover.

Adjustment Suggestion

If the time is adjusted as too long, the valid handover is easily to be


judged as invalid handover.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Arithmetic

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.6.10 MAX count of invalid intra-handover (MaxiHo)


Full Name

MAX count of invalid intra-handover

Abbreviation

MaxiHo

3GPP Name

None

3GPP Reference

None

5-431
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If MS performs handover continuously in the cell, it indicates great


interference in this position and no appropriate channel is available.
In such a case, MS shall be forbidden to perform handover within a
certain time. The judgment method is as follows: If handover occurs
within the invalid intra-handover time, then the previous handover is
considered to have no influence on interference, the counter HoCount
increases by 1 and restart TMaxIHo. If handover occurs after the invalid
intra-handover time, the previous handover is considered valid and clear
the counter to 0.
If the counter value reaches the value of MAX count of invalid
intra-handover parameter, then it indicates not to attempt handover
Description

within a certain period. Perform penalty in intra-cell penalty mode.

Managed Object

Cell
0..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default value is used to make a correct decision on invalid handover.


If the value is too small, the handover is easily to be judged as invalid

Configuration Rule and

and MS is performed on penalty, which is likely to cause call drop.

Adjustment Suggestion

If the value is too large, the handover is easily to be judged as invalid


interference handover and the number of invalid handover increases.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Arithmetic

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-432
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.6.11 MAX path loss threshold on force handover (MaxLossThs)


Full Name

MAX path loss threshold on force handover

Abbreviation

MaxLossThs

3GPP Name

None

3GPP Reference

None
Directed handover is performed only for one designated cell and it is
restricted by a tolerable level difference MaxLevDiff. This level difference
is lower than PBGT handover threshold in reverse direction, thus to
avoid toggle handover.
Directed handover should not cause congestion in the destination cell.
Therefore, transfer reserved resource threshold is set. Perform forced
transfer when the destination cell resource is less than the threshold.
Select users with small path loss and small TA as transferred users.
Users are transferred when their path loss is less than this parameter
and TA is less than the MAX time advance threshold on force handover
parameter. This algorithm applies to cases such as dual-frequency
networking, 900 M cell and 1800 M cell share the same site address.
When MAX time advance threshold on force handover (MaxTAThs) is
63, the forced handover decision is made only according to the path
loss. When MAX path loss threshold on force handover (MaxLossThs) is
150, the forced handover decision is made only according to TA.
The N value of force handover parameter and P value of force handover
parameter are used for decision in actual situations. In other words,
handover conditions are met if HoForceP of HoForceN measurement
reports satisfy requirement.
Path loss L = BS_TXPWR - AV_RXLEV_DL
BS_TXPWR is transmission power of the carrier where occupied
timeslot locates. It depends on the carriers maximum transmission
power, static attenuation power, and power control.AV_RXLEV_DL is
the downlink-receiving level.
Therefore, forced handover shall meet the following requirements:
Level of destination cell must be higher than local cell by maximum level
difference;
Available resource of destination cell must be higher than transfer
reserved resource threshold;
Path loss L must be less than MAX path loss threshold on force
handover and TA must be less than MAX time advance threshold on
force handover;

Description

Destination cell is forced transfer cell.

Managed Object

Cell
0..150

Value Range and Step

Step: 1
5-433

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

110
The forced transfer judgement is made on many conditions, so the

Default Value

allowed maximum path loss should not be too small, but it also should

Configuration Reason

not be too large. If the value is set as the maximum value, this parameter
is invalid. It is proper to set the value as 110.
Forced handover shall meet the following requirements: Level of the
destination cell must be higher than that of the local cell by MaxLevDiff;
available resource of the destination cell must be higher than the

Configuration Rule and

handover reserved resource threshold HoForceResThs; the path

Adjustment Suggestion

loss L must be less than MaxLossThs and the TA must be less than
MaxTAThs. The higher the path loss is, the poorer the signal intensity
of the destination cell is, thereby the max path loss threshold cannot
be too large.

Change Mode

Offline

Related features

ZGO-02-02-003 Directed-Shift Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Handover Arithmetic
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.6.12 MAX time advance threshold on force handover (MaxTAThs)


Full Name

MAX time advance threshold on force handover

Abbreviation

MaxTAThs

3GPP Name

None

3GPP Reference

None

5-434
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Directed handover is performed only for one designated cell and it is


restricted by a tolerable level difference MaxLevDiff. This level difference
is lower than PBGT handover threshold in reverse direction, thus to
avoid toggle handover.
Directed handover should not cause congestion in the destination cell.
Therefore, transfer reserved resource threshold is set. Perform forced
transfer when the destination cell resource is less than the threshold.
Select users with small path loss and small TA as transferred users.
Users are transferred when their path loss is less than this parameter
and TA is less than the MAX time advance threshold on force handover
parameter. This algorithm applies to cases such as dual-frequency
networking, 900 M cell and 1800 M cell share the same site address.
When MAX time advance threshold on force handover (MaxTAThs) is
63, the forced handover decision is made only according to the path
loss. When MAX path loss threshold on force handover (MaxLossThs) is
150, the forced handover decision is made only according to TA.
The N value of force handover parameter and P value of force handover
parameter are used for decision in actual situations. In other words,
handover conditions are met if HoForceP of HoForceN measurement
reports satisfy requirement.
Path loss L = BS_TXPWR - AV_RXLEV_DL
BS_TXPWR is transmission power of the carrier where occupied
timeslot locates. It depends on the carriers maximum transmission
power, static attenuation power, and power control.AV_RXLEV_DL is
the downlink-receiving level.
Therefore, forced handover shall meet the following requirements:
Level of destination cell must be higher than local cell by maximum level
difference;
Available resource of destination cell must be higher than transfer
reserved resource threshold;
Path loss L must be less than MAX path loss threshold on force
handover and TA must be less than MAX time advance threshold on
force handover;
Description

Destination cell is forced transfer cell.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The forced transfer judgement is made on many conditions, so the


maximum time advance should not be too large. Otherwise, the adjacent
cell's signal is poor. It is proper to set the value as 5.

5-435
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Forced handover shall meet the following requirements: Level of the


destination cell must be higher than that of the local cell by MaxLevDiff;
Configuration Rule and
Adjustment Suggestion

available resource of the destination cell must be higher than the


handover reserved resource threshold HoForceResThs; the path loss L
must be less than MaxLossThs and the TA must be less than MaxTAThs.
TA value cnnot be too large. The larger the TA value is, the poorer the
cell signal intensity is.

Change Mode

Offline

Related features

ZGO-02-02-003 Directed-Shift Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Arithmetic

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.6.13 N value of force handover (HoForceN)


Full Name

N value of force handover

Abbreviation

HoForceN

3GPP Name

None

3GPP Reference

None

5-436
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Directed handover is performed only for one designated cell and it is


restricted by a tolerable level difference MaxLevDiff. This level difference
is lower than PBGT handover threshold in reverse direction, thus to
avoid toggle handover.
Directed handover should not cause congestion in the destination cell.
Therefore, transfer reserved resource threshold is set. Perform forced
transfer when the destination cell resource is less than the threshold.
Select users with small path loss and small TA as transferred users.
Users are transferred when their path loss is less than this parameter
and TA is less than the MAX time advance threshold on force handover
parameter. This algorithm applies to cases such as dual-frequency
networking, 900 M cell and 1800 M cell share the same site address.
When MAX time advance threshold on force handover (MaxTAThs) is
63, the forced handover decision is made only according to the path
loss. When MAX path loss threshold on force handover (MaxLossThs) is
150, the forced handover decision is made only according to TA.
The N value of force handover parameter and P value of force handover
parameter are used for decision in actual situations. In other words,
handover conditions are met if HoForceP of HoForceN measurement
reports satisfy requirement.
Path loss L = BS_TXPWR - AV_RXLEV_DL
BS_TXPWR is transmission power of the carrier where occupied
timeslot locates. It depends on the carriers maximum transmission
power, static attenuation power, and power control.AV_RXLEV_DL is
the downlink-receiving level.
Therefore, forced handover shall meet the following requirements:
Level of destination cell must be higher than local cell by maximum level
difference;
Available resource of destination cell must be higher than transfer
reserved resource threshold;
Path loss L must be less than MAX path loss threshold on force
handover and TA must be less than MAX time advance threshold on
force handover;
Description

Destination cell is forced transfer cell.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is most proper for forced handover decisions when N value is set to 4

Configuration Reason

and P value is set to 3 based on the site configuration experience.

5-437
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

NWhen P times in the N times decision succeed, it is allowed to initiate


handover. The smaller the N value and P value are, it is easier to initiate
handover.

Change Mode

Offline

Related features

ZGO-02-02-003 Directed-Shift Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Arithmetic

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.6.14 P value of force handover (HoForceP)


Full Name

P value of force handover

Abbreviation

HoForceP

3GPP Name

None

3GPP Reference

None
Directed handover is performed only for one designated cell and it is
restricted by a tolerable level difference MaxLevDiff. This level difference
is lower than PBGT handover threshold in reverse direction, thus to
avoid toggle handover.
Directed handover should not cause congestion in the destination cell.
Therefore, transfer reserved resource threshold is set. Perform forced
transfer when the destination cell resource is less than the threshold.
Select users with small path loss and small TA as transferred users.
Users are transferred when their path loss is less than this parameter
and TA is less than the MAX time advance threshold on force handover
parameter. This algorithm applies to cases such as dual-frequency

Description

networking, 900 M cell and 1800 M cell share the same site address.

5-438
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

When MAX time advance threshold on force handover (MaxTAThs) is


63, the forced handover decision is made only according to the path
loss. When MAX path loss threshold on force handover (MaxLossThs) is
150, the forced handover decision is made only according to TA.
The N value of force handover parameter and P value of force handover
parameter are used for decision in actual situations. In other words,
handover conditions are met if HoForceP of HoForceN measurement
reports satisfy requirement.
Path loss L = BS_TXPWR - AV_RXLEV_DL
BS_TXPWR is transmission power of the carrier where occupied
timeslot locates. It depends on the carriers maximum transmission
power, static attenuation power, and power control.AV_RXLEV_DL is
the downlink-receiving level.
Therefore, forced handover shall meet the following requirements:
Level of destination cell must be higher than local cell by maximum level
difference;
Available resource of destination cell must be higher than transfer
reserved resource threshold;
Path loss L must be less than MAX path loss threshold on force
handover and TA must be less than MAX time advance threshold on
force handover;
Destination cell is forced transfer cell.
Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is most proper for forced handover decisions when N value is set to 4

Configuration Reason

and P value is set to 3 based on the site configuration experience.

Configuration Rule and


Adjustment Suggestion

When P times in the N times decison succeed, it is allowed to initiate


handover. The smaller the N value and P value are, it is easier to initiate
handover.

Change Mode

Offline

Related features

ZGO-02-02-003 Directed-Shift Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

5-439
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Handover Arithmetic

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.7 Subcell Parameters


5.3.7.1 The MAX of path loss (PathLossMax)
Full Name

The MAX of path loss

Abbreviation

PathLossMax

3GPP Name

None

3GPP Reference

None
This parameter is one of the subcell handover parameters. It is the maximum path loss.During assignment, if byPathLossPathLossMin and TA
SubCellTAMin, the second subcell channel will be selected first. If byPathLossPathLossMin or TASubCellTAMin, only the first subcell channel is available.During handover, when the current call is in subcell 1, if
value TA is smaller than the SubCellTAMin threshold set by the cell parameter and the path loss calculated by downlink level is smaller than the
PathLossMin threshold set by the cell parameter(That is, more than SubCellP in SubCellN satisfy byPathLossPathLossMin and TASubCellTAMin), and MS supports the frequency band of subcell 2, the handover
condition of subcell is met and handover is performed from subcell 1 to
subcell 2. When the current call is in the subcell 2, if the pass loss of subcellN and more than subcellP in value TA satisfy PathLossPathLossMax
or TASubCellTAMax, the conditions of pass loss and TA handover are

Description

met and handover is performed from subcell 2 to subcell 1.

Managed Object

Cell

Value Range and Step

0..150 step: 1

Unit

dB

Default Value

126

Default Value
Configuration Reason

The default value is the experience value of common radio network.

5-440
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and

The larger the value is, it is more difficult to initiate handover from subcell

Adjustment Suggestion

2 to subcell 1 due to pass loss, and vice versa it is easier.

Change Mode

Offline

Related features

ZGO-04-02-005 Co-BCCH

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Subcell parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.7.2 The MIN of path loss (PathLossMin)


Full Name

The MIN of path loss

Abbreviation

PathLossMin

3GPP Name

None

3GPP Reference

None
This parameter is one of the subcell handover parameters. It is the mini-

Description

mum path loss.For its description, refer to PathLossMax.

Managed Object

Cell

Value Range and Step

0..150 step: 1

Unit

dB

Default Value

120

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion
Change Mode

The default value is the experience value of common radio network.


The larger the value is, it is easier to initiate handover in subcell 2
and handover is easier to be performed from subcell 1 to subcell 2.
Otherwise, it is more difficult.
Offline
5-441

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGO-04-02-005 Co-BCCH

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Subcell parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.7.3 The MAX of time advance (SubCellTAMax)


Full Name

The MAX of time advance

Abbreviation

SubCellTAMax

3GPP Name

None

3GPP Reference

None
This parameter is one of the subcell handover parameters. It is the max-

Description

imum threshold of TA.For its description, refer to PathLossMax.

Managed Object

Cell

Value Range and Step

0..63 step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default value is the experience value of common radio network.

Configuration Rule and

The larger the value is, it is more difficult for TA to initiate handover from

Adjustment Suggestion

subcell 2 to subcell 1, and vice versa it is easier.

Change Mode

Offline

Related features

ZGO-04-02-005 Co-BCCH

Related Parameters

None

Relationship

None
5-442

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Subcell parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.7.4 The MIN of time advance (SubCellTAMin)


Full Name

The MIN of time advance

Abbreviation

SubCellTAMin

3GPP Name

None

3GPP Reference

None
This parameter is one of the subcell handover parameters. It is the mini-

Description

mum threshold of TA.For its description, refer to PathLossMax.

Managed Object

Cell

Value Range and Step

0..63 step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is the experience value of common radio network.


The larger the value is, it is easier to initiate handover in subcell 2 and
handover is easier from subcell 1 to subcell 2.Otherwise, it is more
difficult.

Change Mode

Offline

Related features

ZGO-04-02-005 Co-BCCH

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

5-443
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Subcell parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.7.5 Handover Parameter N of SubCell1 (SubCell1N)


Full Name

Handover Parameter N of SubCell1

Abbreviation

SubCell1N

3GPP Name

None

3GPP Reference

None
This parameter is one of the conditions used to decide inter-subcell han-

Description

dover. For its description, refer to PathLossMax.

Managed Object

Cell

Value Range and Step

1..10 step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is the experience value of common radio network.


The value is used in combination of P value of subcell handover. The
larger the P/N is, it is more difficult to meet handover conditions, and
vice versa it is easier.

Change Mode

Offline

Related features

ZGO-04-02-005 Co-BCCH

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-444
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Subcell parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.7.6 Handover Parameter P of SubCell1 (SubCell1P)


Full Name

Handover Parameter P of SubCell1

Abbreviation

SubCell1P

3GPP Name

None

3GPP Reference

None
This parameter is one of the conditions used to decide inter-subcell han-

Description

dover. For its description, refer to PathLossMax.

Managed Object

Cell

Value Range and Step

1..10 step: 1

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is the experience value of common radio network.


The value is used in combination of P value of subcell handover. The
larger the P/N is, it is more difficult to meet handover conditions, and
vice versa it is easier.

Change Mode

Offline

Related features

ZGO-04-02-005 Co-BCCH

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Subcell parameters
5-445
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.7.7 Handover Parameter N of SubCell2 (SubCell2N)


Full Name

Handover Parameter N of SubCell2

Abbreviation

SubCell2N

3GPP Name

None

3GPP Reference

None

Description

Handover Parameter N of SubCell2

Managed Object

CELL

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason

Ensure the stability and reliability of the handover decision.

Configuration Rule and


Adjustment Suggestion

To speed up the handover decision, reduce the value.

Change Mode

Offline

Related features

None

Related Parameters

SubCell2P

Relationship

SubCell2N>=SubCell2P

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> Handover


Control->Subcell params

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5-446
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.3.7.8 Handover Parameter P of SubCell2 (SubCell2P)


Full Name

Handover Parameter P of SubCell2

Abbreviation

SubCell2P

3GPP Name

None

3GPP Reference

None

Description

Handover Parameter P of SubCell2

Managed Object

CELL

Value Range and Step

1..10

Unit

None

Default Value

Default Value
Configuration Reason

Ensure the stability and reliability of the handover decision.

Configuration Rule and


Adjustment Suggestion

To speed up the handover decision, reduce the value.

Change Mode

Offline

Related features

None

Related Parameters

SubCell2N

Relationship

SubCell2N>=SubCell2P

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> Handover


Control->Subcell params

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.3.7.9 SubCell2 To SubCell1 Handover Threshold (SubCellHoDLThs)


Full Name

SubCell2 To SubCell1 Handover Threshold

Abbreviation

SubCellHoDLThs

3GPP Name

None
5-447

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

None

Description

SubCell2 To SubCell1 Handover Threshold

Managed Object

CELL
0~63
0: < -110dBm
1: -110 ~ -109 dBm
2: -109 ~ -108dBm

61: -50 ~ -49dBm


62: 49 ~ -48dBm

Value Range and Step

63: > -48dBm

Unit

dBm

Default Value

25

Default Value
Configuration Reason

The default level can ensure the normal services of a cell.

Configuration Rule and

If the service quality is still poor after the service is handed over to

Adjustment Suggestion

subcell 1, this threshold can be increased.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID-> Handover


Control->Subcell params

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.3.7.10 Subcell handover aigorithm (HoControl_17)


Full Name

Subcell handover aigorithm

Abbreviation

HoControl_17
5-448

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

None

3GPP Reference

None
This parameter defines two handover modes of subcell handover algo-

Description

rithm: One is based on C/I, and the other is based on path loss and TA.

Managed Object

Cell
The value range and step is based on C/I handover, path loss and TA

Value Range and Step

handover.

Unit

None

Default Value

The default value is based on C/I handover.

Default Value
Configuration Reason

It is recommended to change the current default value based on C/I


handover into the default value of the handover algorithm based on
path loss and TA.
It is recommended to change the default value into the handover

Configuration Rule and

algorithm based on path loss and TA. Currently, the on-site enabled

Adjustment Suggestion

COBCCH handover employs the handover algorithm based on path


loss and TA.

Change Mode

Offline
ZGO-04-02-005 Co-BCCH & ZGO-05-02-009 Concentric Circle Technol-

Related features

ogy

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Subcell parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.7.11 Inter Site handover to Subcell2 permitted (HoToInnerSC)


Full Name

Inter Site handover to Subcell2 permitted

5-449
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

HoToInnerSC

3GPP Name

None

3GPP Reference

None
This parameter indicates whether it is allowed to perform handover from
other sites (including the sites of external BSC) to the subcell 2 of this

Description

cell.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


If the subcell is available and it is better for the subcell 2 to share more

Configuration Rule and

traffic, this function should be enabled.After this function is enabled,

Adjustment Suggestion

capability of absorbing traffic of the subcell 2 can be enhanced, but


handover success rate will be influenced.

Change Mode

Offline

Related features

ZGO-04-02-005 Co-BCCH

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Subcell parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.7.12 PBGT Handover Start Threshold of Subcell 2 (PbgtHoStartThsSC2)


Full Name

PBGT Handover Start Threshold of Subcell 2

5-450
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Abbreviation

PbgtHoStartThsSC2

3GPP Name

Null

3GPP Reference

Null
This parameter indicates the PBGT handover initiation threshold in the

Description

second subcell.

Managed Object

CELL
0 .. 63 corresponds to -110dbm..-47dbm

Value Range and Step

step: 1

Unit

Null

Default Value

35

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork->BSC Managed Element->Config SetBSC


Function->Site Config->Site->Cell->Handover control->Subcell Params

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

5.3.7.13 FR to AMRHR Handover Load Threshold of Subcell 2 (FrToAmrHrHoLoad


ThSC2)
Full Name

FR to AMRHR Handover Load Threshold of Subcell 2

Abbreviation

FrToAmrHrHoLoadThSC2

3GPP Name

Null

3GPP Reference

Null
5-451

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the load threshold for performing the FR-to-HR
Description

handover in the second subcell.

Managed Object

CELL
[20..100]

Value Range and Step

step: 1

Unit

Default Value

80

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

Related features

Null

Related Parameters

FrToHrHoLoadThrSC2

Relationship

FrToAmrHrHoLoadThSC2 <= FrToHrHoLoadThrSC2

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork->BSC Managed Element->Config SetBSC


Function->Site Config->Site->Cell->Handover control->Subcell Params

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

5.3.7.14 FR to HR Handover Load Threshold of Subcell 2 (FrToHrHoLoadThrSC2)


Full Name

FR to HR Handover Load Threshold of Subcell 2

Abbreviation

FrToHrHoLoadThrSC2

3GPP Name

Null

3GPP Reference

Null
This parameter indicates the load threshold for performing the FR-to-

Description

HR(V1) handover in the second subcell.

Managed Object

CELL

5-452
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

[20..100]
Value Range and Step

step: 1

Unit

Default Value

90

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork->BSC Managed Element->Config SetBSC


Function->Site Config->Site->Cell->Handover control->Subcell Params

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

V1
to FR for Subcell2 (HrToFrHoLoadThrSC2)
5.3.7.15 The load of HO from HR
Full Name

The load of HO from HRV1 to FR for Subcell2

Abbreviation

HrToFrHoLoadThrSC2

3GPP Name

None

3GPP Reference

None
This parameter specifies the load threshold for initiating the handover from
HR (V1) to FR. When the load of subcell 2 is lower than this parameter
value, the handover from HR (V1) to FR is initiated to improve speech

Description

quality.

Managed Object

CELL

Value Range and Step

0..100

Unit

5-453
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Default Value
Configuration Reason

30
This parameter balances the subscriber's experience and the channel
load. When the channel load is less than 30, a handover to full-rate
mode can be performed to improve subscriber's experience.
A handover to full-rate mode increases the channel load, which might

Configuration Rule and

exceed the dynamic HR threshold. Therefore, a good balance must be

Adjustment Suggestion

kept between the two thresholds to ensure good subscriber experience


without causing frequent handovers.

Change Mode

Offline

Related features

None

Related Parameters

AmrHrToFrHoLoadThSC2

Relationship

AmrHRThs >HrToFrHoLoadThrSC2> =AmrHrToFrHoLoadThSC2


FrToHrHoLoadThrSC2> HrToFrHoLoadThrSC2

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover

OMC->GERAN subnetwork ID->BSC Managed Element ID->Config


Control->Subcell Params
Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

V3
to FR for Subcell2 (AmrHrToFrHoLoadThSC2)
5.3.7.16 The load of HO from HR
Full Name

The load of HO from HRV3 to FR for Subcell2

Abbreviation

AmrHrToFrHoLoadThSC2

3GPP Name

None

3GPP Reference

None
This parameter specifies the load threshold for initiating the handover from
HR (V3) to FR. When the load of subcell 2 is lower than this parameter
value, the handover from HR (V1) to FR is preferred, the handover from

Description

HR (V3) to FR is the second preferred choice.

Managed Object

CELL

Value Range and Step

0..100
5-454

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

Default Value

20

Default Value
Configuration Reason

This parameter balances the subscriber's experience and the channel


load. When the channel load is less than 20, a handover to AMR full rate
can be performed to improve subscriber's experience.
A handover to AMR full-rate mode increases the channel load, which

Configuration Rule and


Adjustment Suggestion

might exceed the dynamic HR threshold. Therefore, a good balance


must be kept between the two thresholds to ensure good subscriber
experience without causing frequent handovers.

Change Mode

Offline

Related features

None

Related Parameters

HrToFrHoLoadThrSC2

Relationship

AmrHRThs >HrToFrHoLoadThrSC2>= AmrHrToFrHoLoadThSC2


FrToAmrHrHoLoadThSC2> AmrHrToFrHoLoadThSC2

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->Site config->Site ID->Cell ID->Handover


Control->Subcell Params

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.3.7.17 Traffic Threshold of Handover in SubCell1 (SC1LoadThs1)


Full Name

Traffic Threshold of Handover in SubCell1

Abbreviation

SC1LoadThs1

3GPP Name

None

3GPP Reference

None
Sets the cell load threshold for handing the UE over from subcell 2 to
subcell 1.
If the UE is in subcell 2, and subcell 1 is set as the preferred cell, the UE
is handed over to subcell 1 when subcell handover condition is met and

Description

the load of subcell 1 is less than this parameter value.


5-455

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

CELL

Value Range and Step

0~100

Unit

Default Value

50

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site config->Site ID->Cell ID->Handover


Control->Subcell Params

Parameter Modifying
Version

iBSCV6.20.713a

Parameter Modifying
Detail

NEW

5.3.7.18 Traffic Threshold of Handover out SubCell1 (SC1LoadThs2)


Full Name

Traffic Threshold of Handover out SubCell1

Abbreviation

SC1LoadThs2

3GPP Name

None

3GPP Reference

None
Sets the cell load threshold for handing the UE over from subcell 1 to
subcell 2.
If the UE is in subcell 1, and subcell 1 is set as the preferred cell, the UE
is handed over to subcell 2 when subcell handover condition is met and

Description

the load of subcell 1 is greater than this parameter value.

Managed Object

CELL
5-456

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Value Range and Step

0~100

Unit

Default Value

70

Default Value
Configuration Reason

Empirical value

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site config->Site ID->Cell ID->Handover


Control->Subcell Params

Parameter Modifying
Version

iBSCV6.20.713a

Parameter Modifying
Detail

NEW

5.3.8 Weight Average Parameters


5.3.8.1 Quality weight of recent measure value (QUALITYAVERAGEWEIGHT)
Full Name

Quality weight of recent measure value

Abbreviation

QUALITYAVERAGEWEIGHT

3GPP Name

Internal

3GPP Reference

None

5-457
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The quality weight of measurement report is represented by 20


parameters. The average uplink quality and average downlink
quality use this group of parameters. The first parameter indicates
the weight of the latest measurement report.For example, if quality
weight is 100, 80, 60, or 40, and the quality average window size is 4,
QAVG=(Q1*100+Q2*80+Q3*60+Q4*40)/(100+80+60+40) (Q1 is the
Description

latest measurement value of quality) when quality is averaged.

Managed Object

Cell
1..100

Value Range and Step

Step: 1

Unit

None

Default Value

100

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value uses the same weight.


The latest measurement report is set as the larger weight. The handover
success rate, call drops due to handover, and RQ reflect the effect of
parameter setting.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover


Control->Weight Average

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.3.8.2 Level weight of recent measurement value level (LEVELAVERAGEWEIGHT)


Full Name

Level weight of recent measurement value level

Abbreviation

LEVELAVERAGEWEIGHT
5-458

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

None

3GPP Reference

None
This parameter describes the level weight of the latest Nth measurement

Description

value.

Managed Object

Cell
1..100

Value Range and Step

Step: 1

Unit

None

Default Value

100

Default Value
Configuration Reason

This parameter is newly added in the 61 version. All levels keep the
same weight by default so that the handover index does not fluctuate
before and after upgrade.

Configuration Rule and

If necessary, it is recommended to adjust the weight of the latest level

Adjustment Suggestion

to the highest.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Weight Average
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4 SDCCH Handover Control Parameters


There are four sub-interfaces for SDCCH handover control parameters.

5-459
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.4.1 Handover Pretreatment Parameters


5.4.1.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None
This parameter means the site ID. It cannot be modified.

Description

Consistent with managed element ID for SDR.

Managed Object

Site

Value Range and Step

1 ~ 1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover

OMC Access Path


Parameter

Modifying

Version
Parameter
Detail

Control->Handover Pretreatment

None
Modifying
None

5.4.1.2 BTS ID (BtsId)


Full Name

BTS ID
5-460

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell
1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover

OMC Access Path

Control->Handover Pretreatment

5-461
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter

Modifying

Version
Parameter

None
Modifying

Detail

None

5.4.1.3 SDCCH handover control ID (SDCCHHocId)


Full Name

SDCCH handover control ID

Abbreviation

SDCCHHocId

3GPP Name

None

3GPP Reference

None
This parameter means the ID of SDCCH handover control. It cannot be mod-

Description

ified.

Managed Object

Cell

Value Range and Step

1~2

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover

OMC Access Path


Parameter

Modifying

Version
Parameter
Detail

Control->Handover Pretreatment

None
Modifying
None

5-462
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.4.1.4 Number of zero allowed in AV (ZeroAllowed)


Full Name

Number of zero allowed in AV

Abbreviation

ZeroAllowed

3GPP Name

None

3GPP Reference

None
SDCCHallows zero number of measurement reports.
According to GSM specifications, MS can report to BSS the
measurement data of at most six adjacent cells with strongest signal
strength. Thus the measurement results recorded by BSC might not be
consecutive. For cells whose signal strength is less than -110 dBm, the
measurement data are not reported. BSC marks measurement data of
such adjacent cells as 0.
This parameter gives flexibility for 0 occurrences in measurement data
averaging. However, excessive occurrences of 0 indicate that the
adjacent cells are of poor signal strength.
The ZeroAllowed value in average value calculation indicates the
allowed number of 0 in a average value calculation.
To be specific, during averaging, if the count of 0s in the sampling count
exceeds ZeroAllowed, these sampling values are hardly reliable, and
the measurement average will be the sum of the reported values divided
by NCellWindow. If the count of 0s in the reported values does not
exceed ZeroAllowed, these sampling values are much reliable and the
measurement average will be the sum of the reported values divided by
(NCellWindow the count of 0s).

Description

V6.20.614b and later versions will support this parameter.

Managed Object

Cell
0..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Usually with general window value and N value, one null value can be

Configuration Reason

accepted.
The counterpart has more endurance of unsteadiness during

Configuration Rule and

measurement if the parameter gets a bigger value. The parameter value

Adjustment Suggestion

can be adjusted bigger when there are more neighbor cells or more
interference with the radio environment.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

5-463
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.1.5 Uplink power level (HoUlLevWindow)


Full Name

Uplink power level

Abbreviation

HoUlLevWindow

3GPP Name

None

3GPP Reference

None
In the GSM system, BSC makes SDCCH handover decision according
to the measurement data. To avoid the negative impact of burst
measurement values resulting from complicated radio transmission,
BSC, when making handover decision, no longer uses the original
measurement data but uses a series of average values of the
measurement data.
The parameter of sampling count of handover uplink intensity
HoUlLevWindow is the size of the window used to calculate the average
value of uplink signal strength. This size is the number of samples used

Description

in average calculation.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

SDCCH transmission time is short. The window value needs to be set

Configuration Reason

small.

5-464
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Average window value:


Big window value requires more measurement reports for the first
average calculation. The impact of signal fluctuation can be avoided, but
Configuration Rule and
Adjustment Suggestion

the handover will be delayed. Therefore the handover success ratio, call
drop ratio and the coverage ratio will be affected.
Big window value requires few measurement reports for the first average
calculation. The hadover decision will be made quickly, which will cause
wrong or frequent handover. Therefore, the handover success ratio, call
drop ratio and the coverage ratio will be affected.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.1.6 Downlink power level Sample count (HoDlLevWindow)


Full Name

Downlink power level Sample count

Abbreviation

HoDlLevWindow

3GPP Name

None

3GPP Reference

None

5-465
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

In the GSM system, BSC makes SDCCH handover decision according


to the measurement data. To avoid the negative impact of burst
measurement values resulting from complicated radio transmission,
BSC, when making handover decision, no longer uses the original
measurement data but uses a series of average values of the
measurement data.
The parameter HoDlLevWindow represents the window size (i.e. the
number of sample values) used to calculate the average value of
downlink signal intensity.
Description

V6.20.614b and later versions will support this parameter.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter should be set on demand of radio environment.


The parameter value can be set high to get rid of the impact caused by

Configuration Rule and

the incorrect measured value. But if the value is too high, the decision

Adjustment Suggestion

will not be made in time. Possibly there will not be enough time for
measurement because data transmission on SDCCH will not last long.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-466
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.4.1.7 Uplink quality (HoUlQualWindow)


Full Name

Uplink quality

Abbreviation

HoUlQualWindow

3GPP Name

None

3GPP Reference

None
In the GSM system, BSC makes SDCCH handover decision according
to the measurement data. To avoid the negative impact of burst
measurement values resulting from complicated radio transmission,
BSC, when making handover decision, no longer uses the original
measurement data but uses a series of average values of the
measurement data.
The parameter of handover uplink quality average window
HoDlQualWindow is the size of the window used to calculate the average
value of uplink signal quality. This size is the number of samples used in

Description

averaging.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

SDCCH transmission time is short. The window value needs to be set

Configuration Reason

small.
Average window value:
Big window value requires more measurement reports for the first
average calculation. The impact of signal fluctuation can be avoided, but

Configuration Rule and


Adjustment Suggestion

the handover will be delayed. Therefore the handover success ratio, call
drop ratio and the coverage ratio will be affected.
Big window value requires few measurement reports for the first average
calculation. The hadover decision will be made quickly, which will cause
wrong or frequent handover. Therefore, the handover success ratio, call
drop ratio and the coverage ratio will be affected.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

0
5-467

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.1.8 Downlink quality Sample count (HoDlQualWindow)


Full Name

Downlink quality Sample count

Abbreviation

HoDlQualWindow

3GPP Name

None

3GPP Reference

None
In the GSM system, BSC makes SDCCH handover decision according
to the measurement data. To avoid the negative impact of burst
measurement values resulting from complicated radio transmission,
BSC, when making handover decision, no longer uses the original
measurement data but uses a series of average values of the
measurement data.
The parameter of handover downlink quality average window
HoDlQualWindow is the size of the window used to calculate the average
value of downlink signal quality. This size is the number of samples
used in averaging.

Description

V6.20.614b and later versions will support this parameter.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter should be set on demand of radio environment.

Configuration Rule and

the incorrect measured value. But if the value is too high, the decision

Adjustment Suggestion

will not be made in time. Possibly there will not be enough time for

The parameter value can be set high to get rid of the impact caused by

measurement because data transmission on SDCCH will not last long.


Change Mode

Offline

5-468
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.1.9 Distance (DistanceWindow)


Full Name

Distance

Abbreviation

DistanceWindow

3GPP Name

Hreqave

3GPP Reference

3GPP TS 45.008
In the GSM system, BSC makes SDCCH handover decision according
to the measurement data. To avoid the negative impact of burst
measurement values resulting from complicated radio transmission,
BSC, when making handover decision, no longer uses the original
measurement data but uses a series of average values of the
measurement data.
The parameter of sampling count of distance DistanceWindow is the size
of the window used to calculate the average value of the distance from
MS to BTS (actually the Time Advance, TA). This size is the number of

Description

samples used in average value calculation.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

5-469
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

MS data transmission time on SDCCH is short, so the window value


should be small compared with TCH, otherwise the handover decision
will not be made in time.

Configuration Rule and

If there are few sampling for handover decision, wrong decision might

Adjustment Suggestion

be made.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[BSC]ShoEnable

Relationship

This parameter takes effect when the system support SDCCH handover.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Pretreatment
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.1.10 Neighboring cell (NCellWindow)


Full Name

Neighboring cell

Abbreviation

NCellWindow

3GPP Name

None

3GPP Reference

None
In the GSM system, BSC makes SDCCH handover decision according
to the measurement data. To avoid the negative impact of the suddenly
changed measurement values resulting from complicated radio
transmission, BSC, when making handover decision, no longer uses the
original measurement data but uses a series of average values of the
measurement data.
The parameter of adjacent cell average window NCellWindow is the
size of the window used to calculate the average value of adjacent cell
signal strength. This size is the number of samples used in the average

Description

calculation.

5-470
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

SDCCH transmission time is short. The window value needs to be set

Configuration Reason

small.
Average window size:
Big window size requires more measurement reports for the first average
calculation. The impact of signal fluctuation can be avoided, but the

Configuration Rule and


Adjustment Suggestion

handover will be delayed. Therefore the handover success ratio, call


drop ratio and the coverage ratio will be affected.
Small window value requires few measurement reports for the first
average calculation. The handover decision will be made quickly, which
will cause wrong or frequent handovers. Therefore, the handover
success ratio, call drop ratio and the coverage ratio will be affected.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.1.11 Neighbour cell for emergency handover (NcellWindowEmerg)


Full Name

Neighbour cell for emergency handover

Abbreviation

NcellWindowEmerg

3GPP Name

None
5-471

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

None
In the GSM system, BSC makes SDCCH handover decision according
to the measurement data. To avoid the negative impact of burst
measurement values resulting from complicated radio transmission,
BSC, when making handover decision, no longer uses the original
measurement data but uses a series of average values of the
measurement data.
The average value window of neighbor cells for emergency handover is
the number of samples used in the calculation.
The emergency handover include uplink and downlink quality handover,
uplink and downlink level handover, uplink quick fading handover,
sub-cell homocentric circularity handover (handover caused by path loss

Description

and too big TA), downlink quick quality handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

Usually this parameter is set 1. The average value for a neighbor cell
should not be too large because an emergency handover needs to
reflect the measured data in a very short time recently.
Changing the parameter value can impact the sensitivity of the target
cell selection by handover decision. The neighbor cell is not likely to be
chosen as the target cell if the parameter value is big.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

5-472
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.4.2 Handover Threshold Parameters


5.4.2.1 Uplink receive level Threshold, Value N, Value P (HoUlLevThs / HoUlLevN
/ HoUlLevP)
Full Name

Uplink receive level Threshold, Value N, Value P

Abbreviation

HoUlLevThs / HoUlLevN / HoUlLevP

3GPP Name

None

3GPP Reference

None
According to GSM specifications, a decision of handover on SDCCH
depends on the received average value of uplink and downlink signal
strength.
The uplink receiving strength is one of the reasons that cause a
handover. The arbitration process is described in the following: For the
latest N average values of downlink signal strength, if P of the N values
fall below relevant threshold value, perform handover to improve the
downlink signal strength.
The parameter HoDlLevThs defines the related threshold value. The
parameter HoDlLevN defines the related N value. The parameter
HoDlLevP defines the related P value. If this handover condition is met,
an internal handover is usually performed in the cell.
Usually the value of HoDlLevThs should be less than the threshold for
uplink power control (increase). That is, perform power control first. If

Description

power control does not work, perform handover.

Managed Object

Cell
Threshold: 0..63;
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
...
62: -49 dBm .. -48 dBm;
63: > -48 dBm
N value: 1..20;
P value: 1..20

Value Range and Step

Step: 1

Unit

None

Default Value

[15, 3, 2]

5-473
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

Consistent with CS services


The uplink receiving sensitivity is about -112. 5-10 db from this value
can be accepted.
The principle for the parameter setting is the following: as long as the
uplink signal quality meets the requirements, the rescue handover
caused by uplink level will not be triggered. Therefore the number of
handovers can be reduced.
If the RQ0-3 proportion is to be increased, this threshold value should be
raised.

Configuration Rule and

If the parameter is set too high, handovers will happen frequently and

Adjustment Suggestion

the handover success ratio will be lowered.


If the N/P is set high, more average calculation will be conducted in
the measurement process. The arbitration for the handover caused by
uplink level will be conducted slowly, thus the call quality and signal
coverage will be impacted, which will result in call drops.
If the N/P is set low, less average calculation will be conducted in the
measurement process. The arbitration for the handover caused by
uplink level will be conducted quickly, thus the call quality and signal
coverage will be impacted, which will result in call drops.

Change Mode

Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic handover decision criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-474
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.4.2.2 Downlink receive level Value N (HoDlLevN)


Full Name

Downlink receive level Value N

Abbreviation

HoDlLevN

3GPP Name

None

3GPP Reference

None
According to GSM specifications, SDCCH handover decisions depend
on the received average value of uplink and downlink signal strength.
The decision process is as follows: For the latest N average values of
downlink signal strength, if P of the N values fall below relevant threshold
value, perform handover to improve the downlink signal strength.
The parameter HoDlLevThs defines the related threshold. The
parameter HoDlLevN defines the related N value. The parameter
HoDlLevP defines the related P value.
Usually the value of HoDlLevThs should be less than the threshold for
downlink power control (increase). That is, perform power control first. If
power control does not work, perform handover. This parameter can be
set 15 (-96 dBm .. -95 dBm) as the default value.

Description

V6.20.614b and later versions will support this parameter.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter should be set on demand of radio environment.

Configuration Rule and

The handover is has more preciseness and lower real-time performance

Adjustment Suggestion

if the value becomes higher, and vice versa.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoDlLevP

Relationship

HoDlLevP <= HoDlLevN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-475
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.2.3 Downlink receive level Value P (HoDlLevP)


Full Name

Downlink receive level Value P

Abbreviation

HoDlLevP

3GPP Name

None

3GPP Reference

None
According to GSM specifications, SDCCH handover decisions depend
on the received average value of uplink and downlink signal strength.
The decision process is as follows: For the latest N average values of
downlink signal strength, if P of the N values fall below relevant threshold
value, perform handover to improve the downlink signal strength.
The parameter HoDlLevThs defines the related threshold. The
parameter HoDlLevN defines the related N value. The parameter
HoDlLevP defines the related P value.
Usually the value of HoDlLevThs should be less than the threshold for
downlink power control (increase). That is, perform power control first. If
power control does not work, perform handover. This parameter can be
set 15 (-96 dBm .. -95 dBm) as the default value.

Description

V6.20.614b and later versions will support this parameter.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to apply this configuration to ensure the precise and

Configuration Reason

quick handover.

Configuration Rule and


Adjustment Suggestion

Handover is easier to happen if the value becomes higher. If the


parameter value is set too high, call drop will happen easily. If the value
is too low, there will be more handovers.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover


5-476

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

[Cell]HoDlLevN

Relationship

HoDlLevP <= HoDlLevN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.2.4 Downlink receive level Threshold (HoDlLevThs)


Full Name

Downlink receive level Threshold

Abbreviation

HoDlLevThs

3GPP Name

None

3GPP Reference

None
According to GSM specifications, SDCCH handover decisions depend
on the received average value of uplink and downlink signal strength.
The decision process is as follows: For the latest N average values of
downlink signal strength, if P of the N values fall below relevant threshold
value, perform handover to improve the downlink signal strength.
The parameter HoDlLevThs defines the related threshold. The
parameter HoDlLevN defines the related N value. The parameter
HoDlLevP defines the related P value.
Usually the value of HoDlLevThs should be less than the threshold for
downlink power control (increase). That is, perform power control first. If
power control does not work, perform handover. This parameter can be
set 15 (-96 dBm .. -95 dBm) as the default value.

Description

V6.20.614b and later versions will support this parameter.

Managed Object

Cell

5-477
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0..63
0: < -110 dBm;
1: (-110 .. -109)dBm;
...
62: (-49 .. -48) dBm;
63: > -48 dBm
Value Range and Step

Step: 1

Unit

None

Default Value

15

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

-95dbm is the critical value to distinguish good or bad level.


The possibility to start the handover becomes smaller if the quality value
becomes higher. If the parameter value is set too high, call drop will
happen easily. If the value is too low, there will be more handovers.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]PcDlInclLevThs

Relationship

HoDlLevThs < PcDlInclLevThs

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.2.5 Uplink receive quality Threshold, Value N, Value P (HoUlQualThs / HoUlQualN /


HoUlQualP)
Full Name

Uplink receive quality Threshold, Value N, Value P

Abbreviation

HoUlQualThs / HoUlQualN / HoUlQualP

3GPP Name

None

3GPP Reference

None
5-478

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

According to GSM specifications, arbitration for SDCCH can be


conducted after a series of average values of uplink and downlink signal
strength are obtained. The arbitration process is as follows: for the
latest N average values of uplink signal strength, if P of the N values
are higher than the threshold value, perform handover to improve the
uplink signal quality.
The parameter HoDlQualThs defines the related threshold. The
parameter HoDlQualN defines the related N value. The parameter
HoDlQualP defines the related P value.
Usually the value of HoUlQualThs should be higher than the threshold
that causes the uplink power control (increase). That is, perform power
Description

control first. If power control does not work, perform handover.

Managed Object

Cell
Threshold: 0..70;
N value: 1..20;
P value: 1..20

Value Range and Step

Step: 1

Unit

None

Default Value

[49, 3, 2]

Default Value
Configuration Reason

Consistent with CS services


Set this parameter 4 for non-frequency-hop network. ;
Set this parameter 5 for frequency-hop network. ;
If the RQ0-3 proportion is to be increased, this threshold value should
be lowered.
If the parameter value is set too high, the call quality and coverage will
be affected, which will cause call drops;

Configuration Rule and

If the parameter value is set too low, the call quality and coverage will be

Adjustment Suggestion

affected, which will cause call drops;


To keep the sensitivity for the quality judgment, N and P values should
not be set too high. A proper setting can help to improve the handover
speed when the quality is deteriorating. However the success ratio of
handovers can be probably lowered.
It is recommended that the N and P be set 3 and 2, or 2 and 2 in the
circumstance of fast moving.

Change Mode

Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic handover decision criteria

Related Parameters

None

Relationship

None

5-479
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.2.6 Downlink receive quality Value N (HoDlQualN)


Full Name

Downlink receive quality Value N

Abbreviation

HoDlQualN

3GPP Name

None

3GPP Reference

None
According to GSM specifications, SDCCH handover decisions depend
on the received average value of uplink and downlink signal strength.
The decision process is as follows: For the latest N average values of
downlink signal strength, if P of the N values fall below relevant threshold
value, perform handover to improve the downlink signal quality.
The parameter HoDlQualThs defines the related threshold. The
parameter HoDlQualNdefines the related N value. The parameter
HoDlQualP defines the related P value.
Usually the value of HoDlQualThs should be higher than the threshold
(PcDlInclQualThs)for downlink power control (increase). That is, perform
power control first. If power control does not work, perform handover.

Description

V6.20.614b and later versions will support this parameter.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to apply this configuration to ensure the precise and

Configuration Reason

quick handover.

5-480
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and

The handover is has more preciseness and lower real-time performance

Adjustment Suggestion

if the value becomes higher, and vice versa.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoDlQualP

Relationship

HoDlQualP <= HoDlQualN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.2.7 Downlink receive quality Value P (HoDlQualP)


Full Name

Downlink receive quality Value P

Abbreviation

HoDlQualP

3GPP Name

None

3GPP Reference

None
According to GSM specifications, SDCCH handover decisions depend
on the received average value of uplink and downlink signal strength.
The decision process is as follows: For the latest N average values of
downlink signal strength, if P of the N values fall below relevant threshold
value, perform handover to improve the downlink signal quality.
The parameter HoDlQualThs defines the related threshold. The
parameter HoDlQualN defines the related N value. The parameter
HoDlQualP defines the related P value.
Usually the value of HoDlQualThs should be higher than the threshold
(PcDlInclQualThs)for downlink power control (increase). That is, perform
power control first. If power control does not work, perform handover.

Description

V6.20.614b and later versions will support this parameter.

Managed Object

Cell

5-481
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

1..20
Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to apply this configuration to ensure the precise and

Configuration Reason

quick handover.

Configuration Rule and


Adjustment Suggestion

Handover is easier to happen if the value becomes higher. If the


parameter value is set too high, call drop will happen easily. If the value
is too low, there will be more handovers.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoDlQualN

Relationship

HoDlQualP <= HoDlQualN

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.2.8 Downlink receive quality Threshold (HoDlQualThs)


Full Name

Downlink receive quality Threshold

Abbreviation

HoDlQualThs

3GPP Name

None

3GPP Reference

None

5-482
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

According to GSM specifications, SDCCH handover decisions depend


on the received average value of uplink and downlink signal strength.
The decision process is as follows: For the latest N average values of
downlink signal strength, if P of the N values fall below relevant threshold
value, perform handover to improve the downlink signal quality.
The parameter HoDlQualThs defines the related threshold. The
parameter HoDlQualN defines the related N value. The parameter
HoDlQualP defines the related P value.
Usually the value of HoDlQualThs should be higher than the threshold
(PcDlInclQualThs)for downlink power control (increase). That is, perform
power control first. If power control does not work, perform handover.
Description

V6.20.614b and later versions will support this parameter.

Managed Object

Cell
0..70

Value Range and Step

Step: 1

Unit

None

Default Value

49

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The quality levels higher than 49 are poor.


The possibility to start the handover becomes smaller if the quality value
becomes higher. If the parameter value is set too high, call drop will
happen easily. If the value is too low, there will be more handovers.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]PcDlInclQualThs

Relationship

HoDlQualThs > PcDlInclQualThs

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-483
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.4.2.9 Rapid handover Threshold / Value N (RapidHoThs / RapidHoN)


Full Name

Rapid handover Threshold / Value N

Abbreviation

RapidHoThs / RapidHoN

3GPP Name

None

3GPP Reference

None
During fast fading handover, some parameters should be used. During
an SDCCH handover, if the measured uplink signal intensity of a call is
less than rapid handover threshold continuously, it triggers handover of
existing cell to most probable candidate cell.
RapidHoN counter defines the minimum times for which the measured
signal intensity of a call is less than the threshold.
RapidHoThs may be set as 15 (that is, -96 dBm .. -95 dBm) by default,
the same as the level threshold of ordinary handover. The parameter
RapidHoN should be set to ensure that rapid handover is faster than

Description

the ordinary signal level handover.

Managed Object

Cell
Threshold: 0..62;
N value: 1..20

Value Range and Step

Step: 1

Unit

None

Default Value

[10, 2]

Default Value

The level threshold for the uplink quick fading handover is set low. N

Configuration Reason

value is set small to ensure quick triggering.


This parameter takes effect after the parameter HoControl13 is set to
allow the quick level lowering handover. RapidHoThs should be set not

Configuration Rule and


Adjustment Suggestion

larger than downlink level handover threshold, and the decision N value
is smaller the N value for level decision.
It is recommended to use the default values.
Under the situations of fast moving and weak coverage, call drop ratio
can be lowerd.

Change Mode

Offline

Related features

ZGO-02-02-001 Handover between Macro- and Micro-cells

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

5-484
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.2.10 Distance handover Value N (DistanceN)


Full Name

Distance handover Value N

Abbreviation

DistanceN

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008
According to GSM specifications, arbitration for SDCCH can be
conducted after a series of average values of uplink and downlink signal
strength are obtained.
The distance between MS and BTS can impact the handover. The
arbitration process is as follows: For the latest N average values of TA
(distance), if P of the N values are higher than the relevant threshold
value, perform a handover. The handover happens due to MS being out
of the cell serving range.
The parameter DistanceN defines the relevant N value, and parameter

Description

DistanceP defines the relevant P value.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

To ensure the correct and quick handover, it is recommended to set

Configuration Reason

this parameter 3.
If the value is set low, there will few samplings and wrong arbitration

Configuration Rule and

might be made.

Adjustment Suggestion

If the value is set high, arbitration for handover needs more time and
call drop will happen.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

5-485
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

[BSC]ShoEnable
[Cell]DistanceP

Relationship

This parameter takes effect when handovers on SDCCH are supported.


The parameter value should not be lower than DistanceP.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Level
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.2.11 Distance handover Value P (DistanceP)


Full Name

Distance handover Value P

Abbreviation

DistanceP

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008
According to GSM specifications, arbitration for SDCCH can be
conducted after a series of average values of uplink and downlink signal
strength are obtained.
The distance between MS and BTS can impact the handover. The
arbitration process is as follows: For the latest N average values of TA
(distance), if P of the N values are higher than the relevant threshold
value, perform a handover. The handover happens due to MS being out
of the cell serving range.
The parameter DistanceN defines the relevant N value, and parameter

Description

DistanceP defines the relevant P value.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

5-486
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

To ensure the correct and quick handover, it is recommended to set

Configuration Reason

this parameter 2.
If the value is set low, it will be easy to meet the arbitration conditions

Configuration Rule and

and handover will happen frequently.

Adjustment Suggestion

If the value is set high, it will be difficult to meet the arbitration conditions
and handover will not happen frequently.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[BSC]ShoEnable
[Cell]DistanceN

Relationship

This parameter takes effect when handovers on SDCCH are supported.


The parameter value should not be higher than DistanceN.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.2.12 PBGT handover Value N / Value P (PBGTHoN / PBGTHoP)


Full Name

PBGT handover Value N / Value P

Abbreviation

PBGTHoN / PBGTHoP

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008 V5.22.0


During an SDCCH handover, if there are P of N PBGT values meets the

Description

arbitration conditions for handover, the PBGT handover will be conducted.

Managed Object

Cell
N value: 1..20;
P value: 1..20

Value Range and Step

Step: 1

Unit

None

5-487
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

[3, 2]

Default Value

According to the site configuration experience, [3, 2] is the a reasonable

Configuration Reason

default value for the handover.

Configuration Rule and


Adjustment Suggestion
Change Mode

The value adjustment will impact the number of handover attempts. It is


harder for the system to conduct handover if the value becomes higher.
And meantime the risk of call drop increases.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.2.13 Downlink rapid quality drop Value N (DLQUALRAPIDHON)


Full Name

Downlink rapid quality drop Value N

Abbreviation

DLQUALRAPIDHON

3GPP Name

None

3GPP Reference

None

5-488
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter indicates the N value for quick handover due to downlink
quality (on SDCCH). This parameter indicates the N value for quick
handover due to downlink quality (on SDCCH). The quick handover due
to downlink quality is to optimize the call drop rate.
For example, there exists strong interference zone in a cell. After an
MS is handed-over into the cell, the call is drop due to poor downlink
transmission quality. The current algorithm is not suitable, so a new
handover algorithm due to downlink quality is created. The quick
handover adopts the original quality value. The neighbor cell does not
Description

use the window mode. The P value is the same as N value.

Managed Object

Cell
1..21

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to apply this configuration to ensure the precise and

Configuration Reason

quick handover.

Configuration Rule and

The handover is has more preciseness and lower real-time performance

Adjustment Suggestion

if the value becomes higher, and vice versa.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-489
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.4.2.14 Downlink rapid quality drop THS (DLQUALRAPIDHOTHS)


Full Name

Downlink rapid quality drop THS

Abbreviation

DLQUALRAPIDHOTHS

3GPP Name

None

3GPP Reference

None
This parameter indicates the threshold value for quick handover due to
downlink quality on SDCCH. The quick handover due to downlink quality
is to optimize the call drop rate. For example, there exists strong interference zone in a cell. After an MS is handed-over into the cell, the call is
drop due to poor downlink transmission quality. The current algorithm is
not suitable, so a new handover algorithm due to downlink quality is created. The quick handover adopts the original quality value. The neighbor

Description

cell does not use the window mode. The P value is the same as N value.

Managed Object

Cell
0..70

Value Range and Step

Step: 1

Unit

None

Default Value

60

Default Value

If the quality value is higher than 60, quick handover needs to be

Configuration Reason

conducted.
The possibility to start the handover becomes smaller if the quality value

Configuration Rule and

becomes higher. If the parameter value is set too high, call drop will

Adjustment Suggestion

happen easily. If the value is too low, there will be more handovers. This
function increase the risk of handover failure ratio.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Level

Parameter Modifying
Version

None
5-490

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.4.3 Handover Condition Parameters


5.4.3.1 Max time advance threshold between MS and BTS (DistanceThs)
Full Name

Max time advance threshold between MS and BTS

Abbreviation

DistanceThs

3GPP Name

None

3GPP Reference

None
The distance between MS and BTS can impact the handover. The
decision process is as follows: For the latest N average values of TA
(distance), if P of the N values rises above relevant threshold value,
then perform handover. The handover is due to MS being out of the cell

Description

service range.

Managed Object

Cell
The value range for extended cell is 0 .. 219; the value range for
ordinary cell is 0..63

Value Range and Step

. Step: 1

Unit

None

Default Value

63

Default Value

If the distance handover is disabled, set this parameter with the

Configuration Reason

maximum value.

Configuration Rule and


Adjustment Suggestion

TA handover is seldom applied. Set this parameter as needed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-491
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.3.2 Downlink rapid handover enable (HoControl_23)


Full Name

Downlink rapid handover enable

Abbreviation

HoControl_23

3GPP Name

None

3GPP Reference

None
This parameter describes whether to allow the SDCCH handover

Description

triggered by fast moving speed.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for special function. The switch is disabled by default.

Configuration Rule and

SDCCH handover//The handover to a neighbor cell triggered by high

Adjustment Suggestion

moving speed is usually conducted on a high-speed railway.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Condition
5-492
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.3.3 Downlink rapid handover threshold (DLRapidHoThs)


Full Name

Downlink rapid handover threshold

Abbreviation

DLRapidHoThs

3GPP Name

None

3GPP Reference

None
During SDCCH handover, after measurement reports are obtained, it
can be decided whether to conduct downlink fast moving handover.
If the recent N consecutive downlink levels (not the average values) are
higher than the sum of threshold and offset values, handover should be
conducted. The reason for handover is fast moving. The parameter

Description

DLRapidHoN defines the threshold value.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

10

Default Value

According to the site configuration experience, 10 is the a reasonable

Configuration Reason

default value for the handover.

Configuration Rule and

In the circumstance of fast moving, a handover will be triggered when

Adjustment Suggestion

the level of a neighbor cell reaches the threshold.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-493
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.3.4 Downlink rapid handover N (DLRapidHoN)


Full Name

Downlink rapid handover N

Abbreviation

DLRapidHoN

3GPP Name

None

3GPP Reference

None
During SDCCH handover, after measurement reports are obtained, it
can be decided whether to conduct downlink quick handover.
If the recent N consecutive downlink levels (not the average values) are
higher than the sum of threshold and offset values, handover should be
conducted. The reason for handover is rapid moving. The parameter

Description

DLRapidHoN defines the N value.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The N value for the downlink fast moving handover should nit be too

Configuration Reason

high. 2 is a reasonable value.

Configuration Rule and

This handover is caused by fast moving. The decision time can be

Adjustment Suggestion

shorter if N is set smaller.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

5-494
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.3.5 Downlink rapid handover offset of high speed (DLRapidHoOffset_0)


Full Name

Downlink rapid handover offset of high speed

Abbreviation

DLRapidHoOffset_0

3GPP Name

None

3GPP Reference

None
After measurement reports are obtained, it can be decided whether to
conduct SDCCH downlink quick handover.
If the recent N consecutive downlink levels (not the average values) are
higher than the sum of threshold and offset values, handover should be
conducted. The reason for handover is fast moving. The parameter
DLRapidHoOffset_2 defines the offset threshold value for the downlink
fast moving handover when the train speed is lower than 250km/h.

Description

V6.20.614b and later versions will support this parameter.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Different offset value is set for different speed level. Fast moving speed

Configuration Reason

corresponds with small offset value. 0 is the default value.

Configuration Rule and


Adjustment Suggestion

The threshold under fast moving speed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None
5-495

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.3.6 Downlink rapid handover offset of middle speed (SDCCH) (DLRapidHoOffset_1)


Full Name

Downlink rapid handover offset of middle speed (SDCCH)

Abbreviation

DLRapidHoOffset_1

3GPP Name

Internal

3GPP Reference

None
After measurement reports are obtained, the arbitration can be made
for downlink handover caused by fast moving.
The fast moving is one of the triggering cause for downlink handover.
The arbitration process is the following: if the recent N consecutive
downlink levels (not the average values) are higher than the sum of
threshold and offset values, handover should be conducted. The reason
for handover is fast moving. The parameter DLRapidHoOffset_1 defines
the offset threshold for the handover on SDCCH caused by fast moving
speed of 150km//h to 250km/.

Description

V6.20.614b and later versions will support this parameter.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Set this parameter corresponding to the train speed of 150-250km/h.


This configuration fits for the radio covering area of high-speed railway

Configuration Rule and

and expressway with a speed of 150-250km/h.

Adjustment Suggestion

The offset should be set lower if the speed becomes faster. Thus the
handover will be quicker.

5-496
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related features

ZGO-02-02-018 Handover Based on Downlink Level Fast Fading

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.3.7 Downlink rapid handover offset of low speed (DLRapidHoOffset_2)


Full Name

Downlink rapid handover offset of low speed

Abbreviation

DLRapidHoOffset_2

3GPP Name

None

3GPP Reference

None
After measurement reports are obtained, it can be decided whether to
conduct SDCCH downlink quick handover.
If the recent N consecutive downlink levels (not the average values) are
higher than the sum of threshold and offset values, handover should be
conducted. The reason for handover is rapid moving. The parameter
DLRapidHoOffset_2 defines the offset threshold value for the downlink

Description

quick handover when the train speed is lower than 150km/h.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The train speed is usually under 150km/h.

5-497
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This configuration fits for the radio covering area of high-speed railway
Configuration Rule and

and expressway with a speed lower than 150km/h.

Adjustment Suggestion

The offset should be set lower if the speed becomes faster. Thus the
handover becomes more frequent.

Change Mode

Offline

Related features

ZGO-02-02-018 Handover Based on Downlink Level Fast Fading

Related Parameters

[Cell]HoControl_23

Relationship

This parameter takes effect when the system support SDCCH downlink
quick handover.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.4 Handover Control Parameters


5.4.4.1 Allow SDCCH handover (HoControl_0)
Full Name

Allow SDCCH handover

Abbreviation

HoControl_0

3GPP Name

Internal

3GPP Reference

None

Description

This parameter determines if SDCCH handover is allowed.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

There is few handover applications on SDCCH. This function can be

Configuration Reason

enabled if needed.
5-498

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and


Adjustment Suggestion

This function is usually applied in the area with high MS moving speed
or with small coverage. The SDCCH handover can be enabled to avoid
call setup failure.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.4.2 Enable PBGT handover (HoControl_3)


Full Name

Enable PBGT handover

Abbreviation

HoControl_3

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow SDCCH handover triggered

Description

by distance change.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

This parameter is used in a special handover algorithm. It is disabled

Configuration Reason

by default.

Configuration Rule and


Adjustment Suggestion

This parameter is used when extended cell exists in wide coverage


situation. Handover can be applied between an ordinary cell and an
extended cell.
5-499

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.4.3 Allow PBGT handover (HoControl_4)


Full Name

Allow PBGT handover

Abbreviation

HoControl_4

3GPP Name

None

3GPP Reference

None
This parameter indicates whether an SDCCH handover can be

Description

conducted due to standard PBGT.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by PBGT uses the basic handover algorithm.

5-500
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Generally speaking, handover triggered by PBGT is enabled. Under


some special circumstances the function is disabled.
The PBGTHOLAYER parameter and hierarchical parameters can be
Configuration Rule and
Adjustment Suggestion

used together for PBGT handover.


PBGT level parameter and hierarchical parameters can be used together
to delay the PBGT handover. The PBGT handover is conducted in a
same level as much as possible.
PBGT handover helps to improve the success ratio of handover, call
drop ratio and coverage ratio.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.4.4 Perform PBGT handover by DIRECTED retry (HoControl_30)


Full Name

Perform PBGT handover by DIRECTED retry

Abbreviation

HoControl_30

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow directed retry during PBGT
handover on SDCCH. MS can be handed-over to TCH channel of a
better cell after the core network gives an assignment without SDCCH

Description

handover.

Managed Object

Cell

5-501
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

This parameter is a switch for a special function.

Configuration Rule and

"Yes" means when SDCCH handover is conducted, MS is redirected to

Adjustment Suggestion

the TCH channel of a better cell to reduce the call drop ratio.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.4.5 Allow dynamic adjustment of handover priority (HoControl_11)


Full Name

Allow dynamic adjustment of handover priority

Abbreviation

HoControl_11

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow dynamic adjustment of

Description

SDCCH handover priority.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None
5-502

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

No

Default Value
Configuration Reason

This is a switch for special function. The switch is disabled by default.

Configuration Rule and

This function can optimize the traffic distribution. The function is

Adjustment Suggestion

recommended to be enabled in the area with busy traffic.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.4.6 Allow rapid handover (HoControl_12)


Full Name

Allow rapid handover

Abbreviation

HoControl_12

3GPP Name

None

3GPP Reference

None

Description

handover.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

This parameter is used in a special handover algorithm. It is disabled

Configuration Reason

by default.

This parameter determines whether to allow uplink rapid fading

5-503
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The uplink rapid fading handover is applied on MS with fast moving


speed, definite direction and fast fading caused by blocks. If this function
Configuration Rule and

is enabled, some neighbor cells need to be configured for fast fading

Adjustment Suggestion

handover.
Then the call drop ratio and coverage ratio can be improved under
special circumstances.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.4.7 Allow quality handover in uplink (HoControl_19)


Full Name

Allow quality handover in uplink

Abbreviation

HoControl_19

3GPP Name

None

3GPP Reference

None
This parameter describes whether to allow the SDCCH handover

Description

triggered by uplink quality.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by quality uses the basic handover algorithm.

5-504
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

It is recommended to enable the handover triggered by uplink


Configuration Rule and

transmission quality to avoid voice problem or call drops.

Adjustment Suggestion

This function will result in frequent handover, but will help to lower the
call drop ratio.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.4.8 Allow level handover in uplink (HoControl_20)


Full Name

Allow level handover in uplink

Abbreviation

HoControl_20

3GPP Name

None

3GPP Reference

None
This parameter describes whether to allow the SDCCH handover

Description

triggered by uplink level.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by level uses the basic handover algorithm.

5-505
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

It is recommended to disable the rescue handover triggered by uplink


level. For the fast-moving and wide coverage situation, it is better to
Configuration Rule and

enable this function, and the corresponding threshold value needs to

Adjustment Suggestion

be modified.
This function will result in frequent handover, but will help to lower the
call drop ratio.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.4.9 Allow quality handover in downlink (HoControl_21)


Full Name

Allow quality handover in downlink

Abbreviation

HoControl_21

3GPP Name

None

3GPP Reference

None
This parameter describes whether to allow the SDCCH handover

Description

triggered by downlink quality.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by quality uses the basic handover algorithm.

5-506
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

It is recommended to enable the handover triggered by downlink


Configuration Rule and

transmission quality to avoid voice problem or call drops.

Adjustment Suggestion

This function will result in frequent handover, but will help to lower the
call drop ratio.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.4.10 Allow level handover in downlink (HoControl_22)


Full Name

Allow level handover in downlink

Abbreviation

HoControl_22

3GPP Name

None

3GPP Reference

None
This parameter describes whether to allow the SDCCH handover

Description

triggered by downlink level.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by level uses the basic handover algorithm.

5-507
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

It is recommended to enable the handover triggered by downlink


Configuration Rule and

transmission quality to avoid voice problem or call drops.

Adjustment Suggestion

This function will result in frequent handover, but will help to lower the
call drop ratio.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.4.11 Allow downlink quality rapid handover (HoControl_25)


Full Name

Allow downlink quality rapid handover

Abbreviation

HoControl_25

3GPP Name

None

3GPP Reference

None
Some cells have strong interference zone. When an MS is handed-over
into these cells, call drop occurs due to poor downlink transmission
quality. A downlink handover caused by poor quality is added for rescue.
The handover caused by poor quality adopts the original quality value.
The neighbor cell does not use the window mode. The N value is the
same as N value used in arbitration. The priority of downlink handover
caused by poor quality is lower than other types of handovers.
This parameter decides whether a handover for quality is conducted.

Description

This parameter is used with handover on SDCCH.

Managed Object

Cell

Value Range and Step

Yes/No

5-508
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

None

Default Value

No

Default Value

This parameter is enabled when the serving cell has poor downlink

Configuration Reason

transmission quality and supports handover on SDCCH.

Configuration Rule and

This parameter is enabled when the serving cell has poor downlink

Adjustment Suggestion

transmission quality and supports handover on SDCCH.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]ShoEnable

Relationship

This parameter takes effect when the system supports handover on


SDCCH.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.4.4.12 Allow SDCCH handover (HoControl[1]_0)


Full Name

Allow SDCCH handover

Abbreviation

HoControl[1]_0

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow handover on the SDCCH in

Description

the case of medium speed.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No
5-509

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

There are few handover applications on the SDCCH. This function can

Configuration Reason

be enabled if necessary.

Configuration Rule and


Adjustment Suggestion

This function is usually applied in the area with high MS moving speed
or with small coverage. The SDCCH handover can be enabled to avoid
call setup failure when an MS is easy to move out of the cell.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.13 Allow handover due to distance (HoControl[1]_3)


Full Name

Allow handover due to distance

Abbreviation

HoControl[1]_3

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow SDCCH handover due to

Description

distance in the case of medium speed.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

This parameter is used in a special handover algorithm. It is disabled

Configuration Reason

by default.

5-510
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter is used when extended cell exists in a wide-coverage


Configuration Rule and

scenario. The handover due to distance can be applied between an

Adjustment Suggestion

ordinary cell and an extended cell. This handover is not recommended


for other scenarios.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.14 Allow standard PBGT handover (HoControl[1]_4)


Full Name

Allow standard PBGT handover

Abbreviation

HoControl[1]_4

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow SDCCH handover caused

Description

by standard PBGT in the case of medium speed.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by PBGT uses the basic handover algorithm.

5-511
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Generally speaking, PBGT handover is enabled. In some special


scenarios, this function is disabled. For example, PBGT handover from
1800M to 900M is disabled in a dual-band network for traffic sharing,
inter-cell PBGT handover is disabled reversely after the macro-micro
handover is enabled, or PBGT handover is disabled at the boundary of
Configuration Rule and
Adjustment Suggestion

indoor and outdoor.


The PBGTHOLAYER parameter and hierarchical parameters can be
used together for PBGT handover of some adjacent cells.
PBGT inter-layer handover parameter and hierarchical parameters can
be used together to delay the inter-layer PBGT handover. The PBGT
handover is implemented at a same layer as much as possible.
Enabling PBGT handover helps to improve the success ratio of
handover, call drop ratio, and coverage ratio.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Control
Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.15 Allow rapid handover (HoControl[1]_12)


Full Name

Allow rapid handover

Abbreviation

HoControl[1]_12

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow uplink rapid-attenuation han-

Description

dover in the case of medium speed.

Managed Object

Cell

5-512
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

This parameter is used in a special handover algorithm. It is disabled

Configuration Reason

by default.
The uplink rapid-attenuation handover is mainly applied in the scenarios
that are characterized by quick moving speed, strong directionality,
and rapid attenuation caused by blocking. It is recommended that this

Configuration Rule and


Adjustment Suggestion

function be enabled for individual cells and meanwhile configure the


related cells to implement rapid-attenuation handover for some adjacent
cells.
After this function is enabled, the success ratio of handover will be
affected, but the call drop and coverage ratio in special scenarios will
be improved.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.16 Allow quality handover in uplink (HoControl[1]_19)


Full Name

Allow quality handover in uplink

Abbreviation

HoControl[1]_19

3GPP Name

None

3GPP Reference

None

5-513
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines whether to allow SDCCH handover triggered


Description

by uplink quality in the case of medium speed.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by quality uses the basic handover algorithm.


It is recommended that you enable rescue handover triggered by uplink

Configuration Rule and

quality to avoid voice problems or call drops.

Adjustment Suggestion

After being enabled, this function will result in frequent handovers but
will help to lower the call drop ratio.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.17 Allow level handover in uplink (HoControl[1]_20)


Full Name

Allow level handover in uplink

Abbreviation

HoControl[1]_20

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow SDCCH handover triggered

Description

by uplink level in the case of medium speed.


5-514

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by level uses the basic handover algorithm.


It is recommended that you disable the rescue handover triggered by
uplink level. For the fast-moving and wide-coverage scenarios, it is

Configuration Rule and

better to enable this function and meanwhile modify the corresponding

Adjustment Suggestion

thresholds.
After being enabled, this function will result in frequent handovers but
will help to lower the call drop ratio.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.18 Allow quality handover in downlink (HoControl[1]_21)


Full Name

Allow quality handover in downlink

Abbreviation

HoControl[1]_21

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow SDCCH handover triggered

Description

by downlink quality in the case of medium speed.


5-515

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by quality uses the basic handover algorithm.

Configuration Rule and

downlink quality to avoid voice problems or call drops.

Adjustment Suggestion

After being enabled, this function will result in frequent handovers but

It is recommended that you enable rescue handover triggered by

will help to lower the call drop ratio.


Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.19 Allow level handover in downlink (HoControl[1]_22)


Full Name

Allow level handover in downlink

Abbreviation

HoControl[1]_22

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow SDCCH handover triggered

Description

by downlink level in the case of medium speed.

Managed Object

Cell

5-516
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by level uses the basic handover algorithm.


It is recommended that you enable rescue handover triggered by

Configuration Rule and


Adjustment Suggestion

downlink level to avoid voice problems or call drops caused by weak


level.
After being enabled, this function will result in frequent handovers but
will help to lower the call drop ratio.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.20 Downlink rapid handover enable (HoControl[1]_23)


Full Name

Downlink rapid handover enable

Abbreviation

HoControl[1]_23

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow downlink SDCCH rapid han-

Description

dover in the case of medium speed.

Managed Object

Cell

5-517
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter a functional switch, which is disabled by default.

Configuration Rule and

The rapid level handover for adjacent cells is usually applied in special

Adjustment Suggestion

scenarios, for example, high-speed railway scenario.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Condition

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.21 Perform PBGT handover by DIRECTED retry (HoControl[1]_30)


Full Name

Perform PBGT handover by DIRECTED retry

Abbreviation

HoControl[1]_30

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow directed retry during PBGT
handover on SDCCH in the case of medium speed. The MS can be
handed over to the TCH channel of a better cell after the core network

Description

gives an assignment without SDCCH handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes
5-518

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

None

Default Value

Yes

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This parameter is a functional switch.


If this parameter is configured to "Yes", it indicates that the MS is
redirected to the TCH channel of a better cell during SDCCH handover,
so as to reduce the call drop ratio.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.22 Allow SDCCH handover (HoControl[2]_0)


Full Name

Allow SDCCH handover

Abbreviation

HoControl[2]_0

3GPP Name

None

3GPP Reference

None

Description

the case of high speed.

Managed Object

Cell

This parameter determines whether to allow handover on the SDCCH in

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

No

5-519
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

There are few handover applications on the SDCCH. This function can

Configuration Reason

be enabled if necessary.

Configuration Rule and


Adjustment Suggestion

This function is usually applied in the area with high MS moving speed
or with small coverage. The SDCCH handover can be enabled to avoid
call setup failure when an MS is easy to move out of the cell.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.23 Allow handover due to distance (HoControl[2]_3)


Full Name

Allow handover due to distance

Abbreviation

HoControl[2]_3

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow SDCCH handover due to

Description

distance in the case of high speed.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

This parameter is used in a special handover algorithm. It is disabled

Configuration Reason

by default.

5-520
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter is used when extended cell exists in a wide-coverage


Configuration Rule and

scenario. The handover due to distance can be applied between an

Adjustment Suggestion

ordinary cell and an extended cell. This handover is not recommended


for other scenarios.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.24 Allow standard PBGT handover (HoControl[2]_4)


Full Name

Allow standard PBGT handover

Abbreviation

HoControl[2]_4

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow SDCCH handover caused

Description

by standard PBGT in the case of high speed.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by PBGT uses the basic handover algorithm.

5-521
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Generally speaking, PBGT handover is enabled. In some special


scenarios, this function is disabled. For example, PBGT handover from
1800M to 900M is disabled in a dual-band network for traffic sharing,
inter-cell PBGT handover is disabled reversely after the macro-micro
handover is enabled, or PBGT handover is disabled at the boundary of
Configuration Rule and
Adjustment Suggestion

indoor and outdoor.


The PBGTHOLAYER parameter and hierarchical parameters can be
used together for PBGT handover of some adjacent cells.
PBGT inter-layer handover parameter and hierarchical parameters can
be used together to delay the inter-layer PBGT handover. The PBGT
handover is implemented at a same layer as much as possible.
Enabling PBGT handover helps to improve the success ratio of
handover, call drop ratio, and coverage ratio.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Control
Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.25 Allow rapid handover (HoControl[2]_12)


Full Name

Allow rapid handover

Abbreviation

HoControl[2]_12

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow uplink rapid-attenuation han-

Description

dover in the case of high speed.

Managed Object

Cell

5-522
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

This parameter is used in a special handover algorithm. It is disabled

Configuration Reason

by default.
The uplink rapid-attenuation handover is mainly applied in the scenarios
that are characterized by quick moving speed, strong directionality,
and rapid attenuation caused by blocking. It is recommended that this

Configuration Rule and


Adjustment Suggestion

function be enabled for individual cells and meanwhile configure the


related cells to implement rapid-attenuation handover for some adjacent
cells.
After this function is enabled, the success ratio of handover will be
affected, but the call drop and coverage ratio in special scenarios will
be improved.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.26 Allow quality handover in uplink (HoControl[2]_19)


Full Name

Allow quality handover in uplink

Abbreviation

HoControl[2]_19

3GPP Name

None

3GPP Reference

None

5-523
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines whether to allow SDCCH handover triggered


Description

by uplink quality in the case of high speed.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by quality uses the basic handover algorithm.


It is recommended that you enable rescue handover triggered by uplink

Configuration Rule and

quality to avoid voice problems or call drops.

Adjustment Suggestion

After being enabled, this function will result in frequent handovers but
will help to lower the call drop ratio.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.27 Allow level handover in uplink (HoControl[2]_20)


Full Name

Allow level handover in uplink

Abbreviation

HoControl[2]_20

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow SDCCH handover triggered

Description

by uplink level in the case of high speed.


5-524

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by level uses the basic handover algorithm.


It is recommended that you disable the rescue handover triggered by
uplink level. For the fast-moving and wide-coverage scenarios, it is

Configuration Rule and

better to enable this function and meanwhile modify the corresponding

Adjustment Suggestion

thresholds.
After being enabled, this function will result in frequent handovers but
will help to lower the call drop ratio.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.28 Allow quality handover in downlink (HoControl[2]_21)


Full Name

Allow quality handover in downlink

Abbreviation

HoControl[2]_21

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow SDCCH handover triggered

Description

by downlink quality in the case of high speed.


5-525

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by quality uses the basic handover algorithm.

Configuration Rule and

downlink quality to avoid voice problems or call drops.

Adjustment Suggestion

After being enabled, this function will result in frequent handovers but

It is recommended that you enable rescue handover triggered by

will help to lower the call drop ratio.


Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.29 Allow level handover in downlink (HoControl[2]_22)


Full Name

Allow level handover in downlink

Abbreviation

HoControl[2]_22

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow SDCCH handover triggered

Description

by downlink level in the case of high speed.

Managed Object

Cell

5-526
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The handover triggered by level uses the basic handover algorithm.


It is recommended that you enable rescue handover triggered by

Configuration Rule and


Adjustment Suggestion

downlink level to avoid voice problems or call drops caused by weak


level.
After being enabled, this function will result in frequent handovers but
will help to lower the call drop ratio.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.30 Downlink rapid handover enable (HoControl[2]_23)


Full Name

Downlink rapid handover enable

Abbreviation

HoControl[2]_23

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow downlink SDCCH rapid han-

Description

dover in the case of high speed.

Managed Object

Cell

5-527
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This parameter a functional switch, which is disabled by default.

Configuration Rule and

The rapid level handover for adjacent cells is usually applied in special

Adjustment Suggestion

scenarios, for example, high-speed railway scenario.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Condition

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.31 Perform PBGT handover by DIRECTED retry (HoControl[2]_30)


Full Name

Perform PBGT handover by DIRECTED retry

Abbreviation

HoControl[2]_30

3GPP Name

None

3GPP Reference

None
This parameter determines whether to allow directed retry during PBGT
handover on SDCCH in the case of high speed. The MS can be handed
over to the TCH channel of a better cell after the core network gives an

Description

assignment without SDCCH handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes
5-528

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

None

Default Value

Yes

Default Value
Configuration Reason

This parameter is a functional switch.


This parameter is used when extended cell exists in a wide-coverage

Configuration Rule and


Adjustment Suggestion

scenario. The handover due to distance can be applied between an


ordinary cell and an extended cell. This handover is not recommended
for other scenarios.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->SDCCH Handover


Control->Handover Control

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.4.4.32 Back to Source Cell when PBGT Handover (PBGTHoBacktoSource)


Full Name

Back to Source Cell when PBGT Handover

Abbreviation

PBGTHoBacktoSource

3GPP Name

None

3GPP Reference

None
This parameter decides whether to set a requirement on the handover
access level for a PBGT handover. If the requirement is set and the MS
does not meet the required level, the PHY Info is not sent, and the MS

Description

handover fails and returns to the source channel.

Managed Object

CELL

Value Range and Step

0~1

Unit

None
5-529

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value
Configuration Reason

Not enabled

Configuration Rule and

To enable the PBGT handover back function on the SD channel, enable

Adjustment Suggestion

the function.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set

OMC Access Path

ID->BSC Function ID->Site config->Site ID->Cell ID-> SDCCH Handover


Control-> Handover Control

Parameter Modifying
Version

iBSCV6.20.713c

Parameter Modifying
Detail

NEW

5.4.4.33 Back to Source Cell when Other Handover (OtherHoBacktoSource)


Full Name

Back to Source Cell when Other Handover

Abbreviation

OtherHoBacktoSource

3GPP Name

None

3GPP Reference

None
This parameter decides whether to set a requirement on the handover
access level for a non-PBGT handover. If the requirement is set and the
MS does not meet the required level, the PHY Info is not sent, and the

Description

MS handover fails and returns to the source channel.

Managed Object

CELL

Value Range and Step

0~1

Unit

None

Default Value

5-530
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value
Configuration Reason

Not enabled

Configuration Rule and

To enable the Non-PBGT handover back function on the SD channel,

Adjustment Suggestion

enable the function.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set

OMC Access Path

ID->BSC Function ID->Site config->Site ID->Cell ID-> SDCCH Handover


Control-> Handover Control

Parameter Modifying
Version

iBSCV6.20.713c

Parameter Modifying
Detail

NEW

5.4.4.34 HO Access Require Rxlevel offset (HoAccessReqLevOffset)


Full Name

HO Access Require Rxlevel offset

Abbreviation

HoAccessReqLevOffset

3GPP Name

None

3GPP Reference

None
This parameter calculates the level offset relative to the level required by
the handover detection. The value is calculated using the formula: 110-

Description

TargetAverageRxLevel + LinkBalance + (HoAccessReqLevOffset -35)

Managed Object

CELL
0..70

Value Range and Step

If the parameter is set to 35, the corresponding level offset is 0 dBm.

Unit

None

Default Value

45

Default Value
Configuration Reason

The default offset is 10db.


5-531

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and

Set a higher value when it is hoped to lower the requirement for

Adjustment Suggestion

handover detect level.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set

OMC Access Path

ID->BSC Function ID->Site config->Site ID->Cell ID-> SDCCH Handover


Control-> Handover Control

Parameter Modifying
Version

iBSCV6.20.713c

Parameter Modifying
Detail

NEW

5.4.4.35 HO Access Require Rxlevel Select Strategy when Other Handover


(OtherHoAccessLevSel)
Full Name

HO Access Require Rxlevel Select Strategy when Other Handover

Abbreviation

OtherHoAccessLevSel

3GPP Name

None

3GPP Reference

None
This parameter decides the level request selection strategy during handover detection for a non-PBGT request. The options include the minimum access level or the value calculated by the formula (110- TargetAver-

Description

ageRxLevel + LinkBalance + (HoAccessReqLevOffset -35)).

Managed Object

CELL
1~2
1: Expected uplink level

Value Range and Step

2: Minimum allowed access level

Unit

None

Default Value

5-532
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value
Configuration Reason

Strategy 1

Configuration Rule and

If SD related indexes degrade when the handover back is performed

Adjustment Suggestion

according to strategy 1, change to strategy 2.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set

OMC Access Path

ID->BSC Function ID->Site config->Site ID->Cell ID-> SDCCH Handover


Control-> Handover Control

Parameter Modifying
Version

iBSCV6.20.713c

Parameter Modifying
Detail

NEW

5.5 UTRAN Handover Control Parameters


UTRAN handover control parameters are displayed in three tabs.

5.5.1 Basic Properties 1


5.5.1.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None

Description

This parameter means the site ID. It cannot be modified.


Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None
5-533

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover

OMC Access Path


Parameter

Modifying

Version
Parameter

Control->Basic Properties 1

None
Modifying

Detail

None

5.5.1.2 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell

5-534
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover

OMC Access Path


Parameter

Modifying

Version
Parameter
Detail

Control->Basic Properties 1

None
Modifying
None

5-535
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.5.1.3 UTRAN handover control ID (S3GHocId)


Full Name

UTRAN handover control ID

Abbreviation

S3GHocId

3GPP Name

None

3GPP Reference

None
This parameter means the ID of cell UTRAN handover control. It cannot be

Description

modified.

Managed Object

Cell

Value Range and Step

1~2

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover

OMC Access Path


Parameter

Modifying

Version
Parameter
Detail

Control->Basic Properties 1

None
Modifying
None

5.5.1.4 Punishment period of UTRAN cell when handover failure (HoFailPenalTm3G)


Full Name

Punishment period of UTRAN cell when handover failure

Abbreviation

HoFailPenalTm3G

5-536
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

None

3GPP Reference

None
This parameter defines a protection period to prevent an immediate han-

Description

dover after a handover failure.

Managed Object

Cell
1..255

Value Range and Step

Step: 1

Unit

Measurement report period or pre-processing measurement report period

Default Value

Default Value
Configuration Reason

This parameter defines a protection period to prevent an immediate


handover after a handover failure. The steadiness of MS call should
also be considered.
There will be a period of penalty time to prevent handover action on
a user.

Configuration Rule and

If this parameter is set too low, there will not be enough penalty time and

Adjustment Suggestion

handover failures are easy to happen again.


If this parameter is set too high, the penalty time will be too long and call
drops are easy to happen again.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-537
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.5.1.5 Slippery window size for calculating Ec/No or RSCP average value to be zero
(HoWindow3G)
Slippery window size for calculating Ec/No or RSCP average value to be
Full Name

zero

Abbreviation

HoWindow3G

3GPP Name

Hreqave

3GPP Reference

3GPP TS 45.008
In the GSM system, BSC makes handover arbitration according to
the measurement data. To avoid the negative impact of the suddenly
changed measurement values resulting from complicated radio
transmission, BSC, when making handover arbitration, no longer uses
the original measurement data but uses a series of average values of
the measurement data. The measurement data from a UTRAN adjacent
cell should also be averaged.
HoWindowUTRAN of Ec/No or RSCP average value is the window size
to calculate Ec/No or RSCP average value in adjacent UTRAN cell, that

Description

is, number of samples used through average calculation.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Enough number of samples are needed to ensure the correctness of


handover. Meanwhile, a handover should be conducted as early as
possible when the signal is weak to ensure a call drop does not happen
If the value is set low, there will few samplings and wrong arbitration

Configuration Rule and

might be made.

Adjustment Suggestion

If the value is set high, arbitration for handover needs more time and
call drop will happen.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-538
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.1.6 Number that measurement value allowed to be zero (ZeroAllowed3G)


Full Name

Number that measurement value allowed to be zero

Abbreviation

ZeroAllowed3G

3GPP Name

None

3GPP Reference

None
According to GSM specifications, an MS can report the measurement
data of at most six adjacent cells with strongest signal strength. Thus
the measurement results recorded by BSC might not be consecutive.
For cells whose signal strength is less than -110 dBm, the measurement
data are not reported. BSC marks measurement data of such adjacent
cells as 0.
This parameter gives flexibility for occurrences of 0 in measurement
data averaging. However, excessive occurrences of 0 indicate that
the adjacent cells are of poor signal strength. The ZeroAllowed value
in average value calculation indicates the allowed number of 0 in a
average value calculation.
To be specific, during averaging, if the count of 0s in the sampling
count exceeds ZeroAllowed, these sampling values are hardly reliable,
and the measurement average will be the sum of the reported values
divided by NCellWindow. If the count of 0s in the reported values does
not exceed ZeroAllowed, these sampling values are reliable and the
measurement average will be the sum of the reported values divided by

Description

(NCellWindow the count of 0s).

Managed Object

Cell
0..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Occasional occurrence of 0 are acceptable. 0Too many occurrences of

Configuration Reason

0 means that the radio communication quality in adjacent cell is poor.

5-539
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If the allowed number of 0 is too small, some good cells might be missed;
Configuration Rule and
Adjustment Suggestion

If the allowed number of 0 is too big, there might be handover to adjacent


cells with poor signals.
To choose an adjacent cell with good signals, this parameter should be
set as small as possible.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.1.7 UTRAN handover (ServiceHo)


Full Name

UTRAN handover

Abbreviation

ServiceHo

3GPP Name

Service Handover

3GPP Reference

3GPP TS 48.008
This parameter indicates UTRAN handover priority control. MSC sends
Service Handover parameter to BSC through ASSIGNMENT REQUEST
and HANDOVER REQUEST messages. Service Handover parameter
has three values, including "prefer UTRAN handover", "not prefer to
UTRAN handover", "not allow to UTRAN handover", taking actions on
subsequent BSC handover arbitration. ServiceHo can be configured as
the default value used while MSC does not deliver Service Handover
parameter, or be configured as BSC forcedly using the mode set by
ServiceHo instead of using Service Handover parameter delivered by

Description

MSC.

5-540
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Cell
0: Prefer to handover to UTRAN cell;
1: Not prefer to handover to UTRAN cell;
2: Not allow handover to UTRAN cell;
3: Based on the information from MSC, prefer to handover to UTRAN
cell by default;
4: Based on the information from MSC, not prefer to handover to UTRAN
cell by default;
5: Based on the information from MSC, not allow handover to UTRAN

Value Range and Step

cell by default;

Unit

None
3: Based on the information from MSC, prefer to handover to UTRAN cell

Default Value

by default;

Default Value
Configuration Reason

The parameter is configured based on MSC strategy.

Configuration Rule and

The parameter is configured based on MSC strategy, and can be

Adjustment Suggestion

adjusted as needed.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.1.8 FDD/TDD handover (FDDTDDPrio)


Full Name

FDD/TDD handover

Abbreviation

FDDTDDPrio

5-541
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

None

3GPP Reference

None
This parameter indicates the priority control of FDD/TDD handover.
When FDD adjacent cells and TDD adjacent cells exist together, to
control the selection sequence of a target cell, FDDTDDPrio parameter

Description

to show whether to prefer to FDD cell handover or to TDD cell handover.

Managed Object

Cell
0: Prefer to handover to FDD cell;

Value Range and Step

1: Prefer to handover to TDD cell

Unit

None

Default Value

0: Prefer to handover to FDD cell;

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Depends on the actual configuration.


Adjust the parameter according to the actual situations on site. If the
adjacent cell is FDD, handover FDD is preferred; if the adjacent cell is
TDD, handover to TDD is preferred.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.1.9 Threshold for load sharing (LoadHoRSCPThsFDD)


Full Name

Threshold for load sharing

Abbreviation

LoadHoRSCPThsFDD

5-542
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

None

3GPP Reference

None
This parameter is used for traffic handover. First you should configure
a traffic handover threshold and inter-system handover switch. This
parameter is used for arbitration to 3G cell due to traffic overload. If
there are at least HoRSCP_N_FDD RSCP average values are reserved
for an adjacent UTRAN cell in BSC and at least HoRSCP_P_FDD of
HoRSCP_N_FDD latest RSCP average values are not lower than the
sum of LoadHoRSCPThsFDD and HoRSCPOffsetUTRAN, the traffic
handover from GSM to UTRAN can be triggered.

Description

This parameter should not be set higher than HoRSCPThsFDD.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

35

Default Value
Configuration Reason

Usually -75 dBm can ensure the good accessibility and voice quality.
This parameter should not be set higher than HoRSCPThsFDD. To
implement the load-based handover, BSC needs to inform its traffic
load to adjacent BSS or RNS through LOAD INDICATION information
(BSSAP) sent timely.

Configuration Rule and

To implement load measurement and report, the parameter involved

Adjustment Suggestion

include "LoadInd", "LoadValidTime", and "LoadIndPrd". The three


parameters mean whether to turn on the load indicator switch and the
timing strategy for load report.
It is recommended to use the default value if the parameter has not
been used.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]HoRSCPThsFDD

Relationship

This parameter should not be set higher than HoRSCPThsFDD.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-543
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.1.10 Ec/No threshold when handover from GSM to 3G for load sharing
(LoadHoEcNoThsFDD)
Full Name

Ec/No threshold when handover from GSM to 3G for load sharing

Abbreviation

LoadHoEcNoThsFDD

3GPP Name

None

3GPP Reference

None
This parameter is used for traffic handover. First you shall configure a
traffic handover threshold and inter-system handover switch.
This parameter is used for PS arbitration to 3G cell due to traffic overload.
If there are at least HoEcNo_N_FDD RSCP average values are reserved
for an adjacent UTRAN cell in BSC and at least HoEcNo_P_FDD of
HoEcNo_N_FDD latest RSCP average values are not lower than the
sum of LoadHoEcNoThsFDD and HoEcNoOffsetUTRAN, the traffic
handover from GSM to UTRAN can be triggered.

Description

This parameter value should be lower than HoEcNoThsFDD.

Managed Object

Cell
0..49

Value Range and Step

Step: 1

Unit

dB

Default Value

25

Default Value

Usually if EcNo is 25 dBm, good accessibility and voice quality can be

Configuration Reason

ensured.

5-544
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter should not be higher than HoRSCPThsFDD. To


implement the load-based handover, BSC needs to inform its traffic
load to adjacent BSS or RNS through LOAD INDICATION information
(BSSAP) sent timely.
Configuration Rule and

To implement load measurement and report, the parameter involved

Adjustment Suggestion

include "LoadInd", "LoadValidTime", and "LoadIndPrd". The three


parameters mean whether to turn on the load indicator switch and the
timing strategy for load report.
It is recommended to use the default value if the parameter has not
been used.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]HoEcNoThsFDD

Relationship

This parameter should not be higher than HoEcNoThsFDD.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.1.11 RSCP threshold when handover from GSM to TDD for load sharing
(LoadHoRSCPThsTDD)
Full Name

RSCP threshold when handover from GSM to TDD for load sharing

Abbreviation

LoadHoRSCPThsTDD

3GPP Name

None

3GPP Reference

None

5-545
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is used for traffic handover. First you should configure a
traffic handover threshold and inter-system handover switch.
This parameter is used for arbitration to 3G cell due to traffic overload. If
there are at least HoRSCP_N_TDD RSCP average values are reserved
for an adjacent UTRAN cell in BSC and at least HoRSCP_P_TDD of
HoRSCP_N_TDD latest RSCP average values are not lower than the
sum of LoadHoRSCPThsTDD and HoRSCPOffsetUTRAN, the traffic
handover from GSM to UTRAN can be triggered.
Description

This parameter value should be set lower than HoRSCPThsFDD.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

35

Default Value
Configuration Reason

Usually -75 dBm can ensure the good accessibility and voice quality.
This parameter should not be set higher than HoRSCPThsTDD. To
implement the load-based handover, BSC needs to inform its traffic
load to adjacent BSS or RNS through LOAD INDICATION information
(BSSAP) sent timely.

Configuration Rule and

To implement load measurement and report, the parameter involved

Adjustment Suggestion

include "LoadInd", "LoadValidTime", and "LoadIndPrd". The three


parameters mean whether to turn on the load indicator switch and the
timing strategy for load report.
It is recommended to use the default value if the parameter has not
been used.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]HoRSCPThsTDD

Relationship

This parameter should not be set higher than HoRSCPThsTDD.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 1

5-546
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.1.12 2110~2170M frequency band permitted (FDDTrafficHoFreqCtl_0)


Full Name

2110~2170M frequency band permitted

Abbreviation

FDDTrafficHoFreqCtl_0

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether the system is prior to switch the traffic

Description

to the UTRAN FDD 2110-2170M frequency band during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

It is required to configure the FDD frequency bands allowed during

Configuration Reason

traffic handover.

Configuration Rule and

Select the FDD frequency band for absorbing traffic as the target cell

Adjustment Suggestion

during traffic handover according to the network condition.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 1

Parameter Modifying
Version

iBSCV6.20.710

5-547
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

5.5.1.13 925~960M frequency band permitted (FDDTrafficHoFreqCtl_1)


Full Name

925~960M frequency band permitted

Abbreviation

FDDTrafficHoFreqCtl_1

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether the system is prior to switch the traffic

Description

to the UTRAN FDD 925-960M frequency band during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

It is required to configure the FDD frequency bands allowed during

Configuration Reason

traffic handover.

Configuration Rule and

Select the FDD frequency band for absorbing traffic as the target cell

Adjustment Suggestion

during traffic handover according to the network condition.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 1

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5-548
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.5.1.14 869~894M frequency band permitted (FDDTrafficHoFreqCtl_2)


Full Name

869~894M frequency band permitted

Abbreviation

FDDTrafficHoFreqCtl_2

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether the system is prior to switch the traffic

Description

to the UTRAN FDD 869-894M frequency band during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

It is required to configure the FDD frequency bands allowed during

Configuration Reason

traffic handover.

Configuration Rule and

Select the FDD frequency band for absorbing traffic as the target cell

Adjustment Suggestion

during traffic handover according to the network condition.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 1

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.5.1.15 Other frequency band permitted (FDDTrafficHoFreqCtl_7)


Full Name

Other frequency band permitted

Abbreviation

FDDTrafficHoFreqCtl_7
5-549

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether the system is prior to switch the traffic

Description

to another UTRAN FDD frequency band during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

It is required to configure the FDD frequency bands allowed during

Configuration Reason

traffic handover.
Select the FDD frequency band for absorbing traffic as the target cell

Configuration Rule and


Adjustment Suggestion

during traffic handover according to the network condition.


If the frequency band is not the specified FDDTrafficHoFreqCtl_0,
FDDTrafficHoFreqCtl_1, or FDDTrafficHoFreqCtl_2, select
FDDTrafficHoFreqCtl_7, that is, other frequency band.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Basic Properties 1
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.5.1.16 2010~2025M frequency band permitted (TDDTrafficHoFreqCtl_0)


Full Name

2010~2025M frequency band permitted

Abbreviation

TDDTrafficHoFreqCtl_0

3GPP Name

Internal Defination
5-550

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Reference

None
This parameter determines whether the system is prior to switch the traffic

Description

to the 2010-2025M frequency band during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

It is required to configure the TDD frequency bands allowed during

Configuration Reason

traffic handover.

Configuration Rule and

Select the TDD frequency band for absorbing traffic as the target cell

Adjustment Suggestion

during traffic handover according to the network condition.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 1

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.5.1.17 1880~1900M frequency band permitted (TDDTrafficHoFreqCtl_1)


Full Name

1880~1900M frequency band permitted

Abbreviation

TDDTrafficHoFreqCtl_1

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether the system is prior to switch the traffic

Description

to the 1880-1900M frequency band during traffic handover.

5-551
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

It is required to configure the TDD frequency bands allowed during

Configuration Reason

traffic handover.

Configuration Rule and

Select the TDD frequency band for absorbing traffic as the target cell

Adjustment Suggestion

during traffic handover according to the network condition.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Basic Properties 1
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.5.1.18 Other frequency band permitted (TDDTrafficHoFreqCtl_7)


Full Name

Other frequency band permitted

Abbreviation

TDDTrafficHoFreqCtl_7

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether the system is prior to switch the traffic

Description

to another frequency band during traffic handover.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

5-552
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

None

Default Value

No

Default Value

It is required to configure the TDD frequency bands allowed during

Configuration Reason

traffic handover.
Select the TDD frequency band for absorbing traffic as the target cell

Configuration Rule and


Adjustment Suggestion

during traffic handover according to the network condition.


If the frequency band is not the specified FDDTrafficHoFreqCtl_0 or
FDDTrafficHoFreqCtl_1, select FDDTrafficHoFreqCtl_7, that is, other
frequency band.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 1

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.5.2 Basic Properties 2


5.5.2.1 Inter system handover supported (InterSysHoCtrl)
Full Name

Inter system handover supported

Abbreviation

InterSysHoCtrl

3GPP Name

None

3GPP Reference

None
This parameter indicates whether intersystem handover within BSC is allowed. The parameters determines whether BSC can issue handover to

Description

3G system.

Managed Object

Cell
5-553

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The parameter is enabled as needed.


For a BSC, open the InterSysHoCtrl (intersystem) switch in BSC to
support the 2/3G intersystem handover in CS domain. Usually this
parameter adopts the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.2.2 Directed retry to UTRAN cell allowed (InterSysRdCtrl)


Full Name

Directed retry to UTRAN cell allowed

Abbreviation

InterSysRdCtrl

3GPP Name

None

3GPP Reference

None
This parameter determines if allow directed retry to UTRAN cell. When
no service channel is allocated in this cell, a user can try to redirect to
adjacent cell under allowed case by corresponding function switch. If this

Description

parameter is configured as Yes, it can be redirected to 3G adjacent cell.

Managed Object

Cell

5-554
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

The switch should be turned off in the cell without adjacent 3G cells; the

Configuration Reason

switch should be turned on in the cell with adjacent 3Gcells.

Configuration Rule and

If this cell has adjacent 3Gcells, this switch can try to redirect to an

Adjustment Suggestion

adjacent 3G cell when no service channel is allocated in this cell.

Change Mode

Offline

Related features

ZGB-03-01-002 Direct Retry

Related Parameters

[BSC]OutDrEnable

Relationship

If the OutDrEnable parameter is set Yes, the inter-system redirection can


be conducted only when this parameter is set Yes.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.2.3 Handover from GSM to UTRAN FDD RSCP Threshold (HoRSCPThsFDD)


Full Name

Handover from GSM to UTRAN FDD RSCP Threshold

Abbreviation

HoRSCPThsFDD

3GPP Name

None

3GPP Reference

None

5-555
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If there are at least HoRSCP_N_FDD RSCP average values are reserved


for an adjacent UTRAN cell in BSC and at least HoRSCP_P_FDD of
HoRSCP_N_FDD latest RSCP average values is not lower than the sum
of HoRSCPThsFDD and HoRSCPOffsetUTRAN, the PS handover from
GSM to UTRAN can be triggered. This adjacent cell is the candidate tarDescription

get cell for the PS handover.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

35

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Usually -75 dBm can ensure the good accessibility and voice quality.
This parameter indicates the minimum threshold for the handover to
FDD network. Set the parameter according to 2/3G interworking. If
3G network takes priority, this parameter should be set low as needed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Basic Properties 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.2.4 Handover from GSM to UTRAN FDD RSCP Value N (HoRSCP_N_FDD)


Full Name

Handover from GSM to UTRAN FDD RSCP Value N

Abbreviation

HoRSCP_N_FDD

5-556
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

None

3GPP Reference

None
HoRSCP_P_FDD of HoRSCP_N_FDD RSCP average values are not
lower than the sum of HoRSCP_THS_FDD and HoRSCPOffsetUTRAN,

Description

the PS handover from GSM to UTRAN can be triggered.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter ensures correct and quick triggering of a handover.

Configuration Rule and


Adjustment Suggestion

It is recommended to apply the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.2.5 Handover from GSM to UTRAN FDD RSCP Value P (HoRSCP_P_FDD)


Full Name

Handover from GSM to UTRAN FDD RSCP Value P

Abbreviation

HoRSCP_P_FDD

3GPP Name

None

3GPP Reference

None
5-557

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

HoRSCP_P_FDD of HoRSCP_N_FDD RSCP average values are not


lower than the sum of HoRSCP_THS_FDD and HoRSCPOffsetUTRAN,
Description

the PS handover from GSM to UTRAN can be triggered.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter ensures correct and quick triggering of a handover.

Configuration Rule and


Adjustment Suggestion

It is recommended to apply the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Basic Properties 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.2.6 Handover from GSM to UTRAN FDD Ec/No Threshold (HoEcNoThsFDD)


Full Name

Handover from GSM to UTRAN FDD Ec/No Threshold

Abbreviation

HoEcNoThsFDD

3GPP Name

None

3GPP Reference

None

5-558
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

There are at least HoEcNo_N_FDD Ec/No average values are reserved for an adjacent UTRAN cell in BSC. At least HoEcNo_P_FDD
of HoEcNo_N_FDD latest Ec/No average values is not lower than the
sum of HO and HoEcNoOffsetUTRAN, the PS handover from GSM to
UTRAN can be triggered. This adjacent cell is the candidate target cell
Description

for the PS handover.

Managed Object

Cell
0..49

Value Range and Step

Step: 1

Unit

dB

Default Value

25

Default Value
Configuration Reason

Usually 25 dBm can ensure the good accessibility and voice quality.

Configuration Rule and


Adjustment Suggestion

It is recommended to apply the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.2.7 Handover from GSM to UTRAN FDD Ec/No Value N (HoEcNo_N_FDD)


Full Name

Handover from GSM to UTRAN FDD Ec/No Value N

Abbreviation

HoEcNo_N_FDD

3GPP Name

None

5-559
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

None
HoEcNo_P_FDD of HoEcNo_N_FDD Ec/No average values is not lower
than the sum of HO and HoEcNoOffsetUTRAN, the PS handover from

Description

GSM to UTRAN can be triggered.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter ensures correct and quick triggering of a handover.

Configuration Rule and


Adjustment Suggestion

It is recommended to apply the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Basic Properties 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.2.8 Handover from GSM to UTRAN FDD Ec/No Value P (HoEcNo_P_FDD)


Full Name

Handover from GSM to UTRAN FDD Ec/No Value P

Abbreviation

HoEcNo_P_FDD

3GPP Name

None

3GPP Reference

None

5-560
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

HoEcNo_P_FDD of HoEcNo_N_FDD Ec/No average values is not lower


than the sum of HO and HoEcNoOffsetUTRAN, the PS handover from
Description

GSM to UTRAN can be triggered.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter ensures correct and quick triggering of a handover.

Configuration Rule and


Adjustment Suggestion

It is recommended to apply the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.2.9 Handover from GSM to UTRAN TDD RSCP Threshold (HoRSCPThsTDD)


Full Name

Handover from GSM to UTRAN TDD RSCP Threshold

Abbreviation

HoRSCPThsTDD

3GPP Name

None

3GPP Reference

None

5-561
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The parameter defines a threshold. If there are at least HoRSCP_N_TDD


RSCP average values are reserved for an adjacent UTRAN cell in BSC
and at least HoRSCP_P_TDD of HoRSCP_N_TDD latest RSCP average
values are not lower than the sum of HoRSCPThsTDD and HoRSCPOffsetUTRAN, the PS handover from GSM to UTRAN can be triggered. This
Description

adjacent cell is the candidate target cell for the PS handover.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

35

Default Value
Configuration Reason

Usually -75 dBm can ensure the good accessibility and voice quality.
This parameter indicates the minimum threshold for the handover

Configuration Rule and

to FDD network. The parameter should be set according to 2/3G

Adjustment Suggestion

interworking strategy. If 3G network takes priority, this parameter should


be set low as needed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.2.10 Handover from GSM to UTRAN TDD RSCP Value N (HoRSCP_N_TDD)


Full Name

Handover from GSM to UTRAN TDD RSCP Value N

Abbreviation

HoRSCP_N_TDD
5-562

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

None

3GPP Reference

None
The parameter defines a threshold.. If there are at least HoRSCP_N_TDD
RSCP average values are reserved for an adjacent UTRAN cell in BSC
and at least HoRSCP_P_TDD of HoRSCP_N_TDD latest RSCP average
values are not lower than the sum of HoRSCPThsTDD and HoRSCPOffsetUTRAN, the PS handover from GSM to UTRAN can be triggered. This

Description

adjacent cell is the candidate target cell for the PS handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter ensures correct and quick triggering of a handover.

Configuration Rule and


Adjustment Suggestion

It is recommended to apply the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->Basic Properties 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.2.11 Handover from GSM to UTRAN TDD RSCP Value P (HoRSCP_P_TDD)


Full Name

Handover from GSM to UTRAN TDD RSCP Value P

5-563
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

HoRSCP_P_TDD

3GPP Name

None

3GPP Reference

None
The parameter defines a threshold. If there are at least HoRSCP_N_TDD
RSCP average values are reserved for an adjacent UTRAN cell in BSC
and at least HoRSCP_P_TDD of HoRSCP_N_TDD latest RSCP average
values are not lower than the sum of HoRSCPThsTDD and HoRSCPOffsetUTRAN, the PS handover from GSM to UTRAN can be triggered. This

Description

adjacent cell is the candidate target cell for the PS handover.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter ensures correct and quick triggering of a handover.

Configuration Rule and


Adjustment Suggestion

It is recommended to apply the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Basic Properties 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-564
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.5.3 PS Handover Parameters


5.5.3.1 Penalty time of handover failure (HoFailPenalTm3G_PS)
Full Name

Penalty time of handover failure

Abbreviation

HoFailPenalTm3G_PS

3GPP Name

Internal

3GPP Reference

None
If the PS handover to a 3G target cell fails, the cell will be punished in a
period of time, during which no handover will be conducted to this cell.

Description

This parameter determines the penalty duration.

Managed Object

External Neighbor Cell


1..100

Value Range and Step

Step: 1

Unit

Default Value

Default Value
Configuration Reason

Usually 5 S time is long enough for an MS to make changes.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-565
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.5.3.2 Window of calculating 3G cell (HoWindow3G_PS)


Full Name

Window of calculating 3G cell

Abbreviation

HoWindow3G_PS

3GPP Name

Internal

3GPP Reference

None
In the GSM system, BSC makes PS handover arbitration according to
the measurement data. To avoid the negative impact of the suddenly
changed measurement values resulting from complicated radio
transmission, BSC, when making handover arbitration, no longer uses
the original measurement data but uses a series of average values of
the measurement data. The measurement data from UTRAN adjacent
data should also be averaged.
HoWindowUTRAN of Ec/No or RSCP average is the window size to
calculate Ec/No or RSCP average in adjacent UTRAN cell, that is,

Description

number of samples used through average calculation.

Managed Object

External Neighbor Cell


1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter ensures a proper window size.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->PSHOC Parameter

Parameter Modifying
Version

None
5-566

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.5.3.3 Support PS handover of Inter-System (InterSysHoCtrl_PS)


Full Name

Support PS handover of Inter-System

Abbreviation

InterSysHoCtrl_PS

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether intersystem handover within BSC is allowed. This parameters determines whether BSC can issue handover to

Description

3G system.

Managed Object

External Neighbor Cell


0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional parameter, which is not configured by default.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None
5-567

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.5.3.4 Number of zero in measure result (ZeroAllowed3G_PS)


Full Name

Number of zero in measure result

Abbreviation

ZeroAllowed3G_PS

3GPP Name

Internal

3GPP Reference

None
According to GSM specifications, an MS can report to BSS the measurement data of at most six adjacent cells with strongest signal strength.
Thus the measurement results recorded by BSC might not be consecutive. For cells whose signal strength is less than -110 dBm, the measurement data are not reported. BSC marks measurement data of such
adjacent cells as 0. This parameter gives flexibility for 0 occurrences in
measurement data averaging. However, excessive occurrences of 0 indicate that the adjacent cells are of poor signal strength. The ZeroAllowed
value in average value calculation indicates the allowed number of 0 in a
average value calculation. To be specific, during averaging, if the count
of 0s in the sampling count exceeds ZeroAllowed, these sampling values
are hardly reliable, and the measurement average will be the sum of the
reported values divided by NCellWindow. If the count of 0s in the reported
values does not exceed ZeroAllowed, these sampling values are reliable
and the measurement average will be the sum of the reported values di-

Description

vided by (NCellWindow the count of 0s).

Managed Object

External Neighbor Cell


0..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Occasional measurement report missing is acceptable.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

5-568
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.3.5 Priority to FDD or TDD (FDDTDDPrio_PS)


Full Name

Priority to FDD or TDD

Abbreviation

FDDTDDPrio_PS

3GPP Name

Internal

3GPP Reference

None
This parameter can make preferred handover to FDD cells or to TDD
cells. The parameter indicates the priority control of FDD/TDD handover.
When FDD adjacent cell and TDD adjacent cell coexist, to control the
selection sequence of target cell, the FDDTDDPrio parameter is used to

Description

indicate whether to prefer to FDD cell handover or TDD cell handover.

Managed Object

External Neighbor Cell


0: Prefer to handover to FDD cell

Value Range and Step

1: Prefer to handover to TDD cell

Unit

None

Default Value

Default Value
Configuration Reason

Usually handovers to FDD cell happen frequently.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

5-569
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.3.6 RSCP threshold to FDD in load handover (LoadHoRSCPThsFDD_PS)


Full Name

RSCP threshold to FDD in load handover

Abbreviation

LoadHoRSCPThsFDD_PS

3GPP Name

Internal

3GPP Reference

None
This parameter is used for PS handover. First you should configure a
traffic handover threshold and inter-system handover switch. This parameter is used PS arbitration to 3G cell due to traffic overload. If there
are at least HoRSCP_N_FDD_PS RSCP average values are reserved
for an adjacent UTRAN cell in BSC and at least HoRSCP_P_FDD_PS
of HoRSCP_N_FDD_PS latest RSCP average values is not lower than
the sum of LoadHoRSCPThsFDD_PS and HoRSCPOffset3G_PS, the PS
handover from GSM to UTRAN can be triggered. This parameter value

Description

shall be lower than HoRSCPThsFDD_PS.

Managed Object

External Neighbor Cell


0..63

Value Range and Step

Step: 1

Unit

None

Default Value

35

Default Value
Configuration Reason

Usually -75 dBm can ensure the success of handover.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

5-570
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.3.7 Ec/No threshold to FDD in load handover (LoadHoECNoThsFDD_PS)


Full Name

Ec/No threshold to FDD in load handover

Abbreviation

LoadHoECNoThsFDD_PS

3GPP Name

Internal

3GPP Reference

None
This parameter is used for PS handover. First you should set a traffic
threshold and an inter-system handover switch.

This parameter is

used PS arbitration to 3G cell due to traffic overload. If there are at


least HoEcNo_N_FDD_PS RSCP average values are reserved for
an adjacent UTRAN cell in BSC and at least HoEcNo_P_FDD_PS of
HoEcNo_N_FDD_PS latest RSCP average values is not lower than the
sum of LoadHoEcNoThsFDD_PS and HoRSCPOffset3G_PS, the PS
handover from GSM to UTRAN can be triggered. This parameter value
Description

shall be lower than HO_PS.

Managed Object

External Neighbor Cell


0..49

Value Range and Step

Step: 1

Unit

dB

Default Value

25

Default Value

Usually if Ec/No is higher than 25 dB, the handover is more likely to

Configuration Reason

be successful.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

5-571
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->PSHOC Parameter
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.3.8 RSCP threshold to TDD in load handover (LoadHoRSCPThsTDD_PS)


Full Name

RSCP threshold to TDD in load handover

Abbreviation

LoadHoRSCPThsTDD_PS

3GPP Name

Internal

3GPP Reference

None
This parameter is used for PS handover. First you should configure a
traffic handover threshold and inter-system handover switch. This parameter is used PS arbitration to 3G cell due to traffic overload. If there
are at least HoRSCP_N_TDD_PS RSCP average values are reserved
for an adjacent UTRAN cell in BSC and at least HoRSCP_P_TDD_PS
of HoRSCP_N_TDD_PS latest RSCP average values is not lower than
the sum of LoadHoRSCPThsTDD_PS and HoRSCPOffset3G_PS, the PS
handover from GSM to UTRAN can be triggered. This parameter value

Description

shall be lower than HoRSCPThsFDD_PS.

Managed Object

External Neighbor Cell


0..63

Value Range and Step

Step: 1

Unit

None

Default Value

35

Default Value
Configuration Reason

Usually -75 dBm can ensure the success of handover.


5-572

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.3.9 RSCP threshold to FDD (HoRSCPThsFDD_PS)


Full Name

RSCP threshold to FDD

Abbreviation

HoRSCPThsFDD_PS

3GPP Name

Internal

3GPP Reference

None
There are at least HoRSCP_N_FDD_PS RSCP average values are reserved for an adjacent UTRAN cell in BSC. At least HoRSCP_P_FDD_PS
of HoRSCP_N_FDD latest RSCP average values is not lower than the
sum of HoRSCPThsFDD_PS and HoRSCPOffset3G_PS, the PS handover from GSM to UTRAN can be triggered. This adjacent cell is the

Description

candidate target cell for the PS handover.

Managed Object

External Neighbor Cell


0..63

Value Range and Step

Step: 1

Unit

None

Default Value

35

5-573
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

Usually -75 dBm can ensure success of the handover.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.3.10 P of handovering to FDD by RSCP (HoRSCP_P_FDD_PS)


Full Name

P of handovering to FDD by RSCP

Abbreviation

HoRSCP_P_FDD_PS

3GPP Name

Internal

3GPP Reference

None
HoRSCP_P_FDD_PS of HoRSCP_N_FDD_PS RSCP average values
is not lower than the sum of HoRSCP_THS_FDD_PS and HoRSCPOff-

Description

set3G_P, the PS handover from GSM to UTRAN can be triggered.

Managed Object

External Neighbor Cell


0..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

To ensure the correct and quick handover, it is recommended to set

Configuration Reason

this parameter 3.
5-574

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

[External Neighbor Cell]HoEcNo_N_FDD_PS

Relationship

The HoRSCP_P_FDD_PS cannot be higher than HoRSCP_N_FDD_PS.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.3.11 N of handovering to FDD by RSCP (HoRSCP_N_FDD_PS)


Full Name

N of handovering to FDD by RSCP

Abbreviation

HoRSCP_N_FDD_PS

3GPP Name

Internal

3GPP Reference

None
HoRSCP_N_FDD_PS of HoEcNo_N_FDD_PS Ec/No average values
is not lower than the sum of HoRSCP_THS_FDD_PS and HoRSCPOff-

Description

set3G_PS, the PS handover from GSM to UTRAN can be triggered.

Managed Object

External Neighbor Cell


0..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

To ensure the correct and quick handover, it is recommended to set

Configuration Reason

this parameter 4.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.


5-575

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->PSHOC Parameter
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.3.12 EcNo threshold to FDD (HoEcNoThsFDD_PS)


Full Name

EcNo threshold to FDD

Abbreviation

HoEcNoThsFDD_PS

3GPP Name

Internal

3GPP Reference

None
There are at least HoEcNo_N_FDD_PS Ec/No average values are reserved for an adjacent UTRAN cell in BSC. At least HoEcNo_P_FDD_PS
of HoEcNo_N_FDD_PS latest Ec/No average values is not lower than the
sum of HoEcNoThsFDD_PS and HoEcNoOffset3G_PS, the PS handover
from GSM to UTRAN can be triggered. This adjacent cell is the candidate

Description

target cell for the PS handover.

Managed Object

External Neighbor Cell


0..49

Value Range and Step

Step: 1

Unit

None

Default Value

25

Default Value

Usually if Ec/No is higher than 25 dB, the handover is more likely to

Configuration Reason

be successful.

5-576
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.3.13 P of handovering to FDD by EcNo (HoEcNo_P_FDD_PS)


Full Name

P of handovering to FDD by EcNo

Abbreviation

HoEcNo_P_FDD_PS

3GPP Name

Internal

3GPP Reference

None
HoEcNo_P_FDD_PS of HoEcNo_N_FDD_PS Ec/No average values
is not lower than the sum of HoEcNoThsFDD_PS and HoEcNoOff-

Description

set3G_PS, the PS handover from GSM to UTRAN can be triggered.

Managed Object

External Neighbor Cell


0..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

To ensure the correct and quick handover, it is recommended to set

Configuration Reason

this parameter 3.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.


5-577

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

[External Neighbor Cell]HoEcNo_N_FDD_PS

Relationship

The HoEcNo_P_FDD_PS cannot be higher than HoEcNo_N_FDD_PS.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->PSHOC Parameter
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.3.14 N of handovering to FDD by EcNo (HoEcNo_N_FDD_PS)


Full Name

N of handovering to FDD by EcNo

Abbreviation

HoEcNo_N_FDD_PS

3GPP Name

Internal

3GPP Reference

None
HoEcNo_P_FDD_PS of HoEcNo_N_FDD_PS Ec/No average values
is not lower than the sum of HoEcNoThsFDD_PS and HoEcNoOff-

Description

set3G_PS, the PS handover from GSM to UTRAN can be triggered.

Managed Object

External Neighbor Cell


0..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

To ensure the correct and quick handover, it is recommended to set

Configuration Reason

this parameter 4.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover
5-578

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.3.15 RSCP threshold to TDD (HoRSCPThsTDD_PS)


Full Name

RSCP threshold to TDD

Abbreviation

HoRSCPThsTDD_PS

3GPP Name

Internal

3GPP Reference

None
There are at least HoRSCP_N_TDD_PS RSCP average values are reserved for an adjacent UTRAN cell in BSC. At least HoRSCP_P_TDD_PS
of HoRSCP_N_TDD_PS latest RSCP average values is not lower than
the sum of HoRSCPThsTDD_PS and HoRSCPOffset3G_PS, the PS handover from GSM to UTRAN can be triggered. This adjacent cell is the

Description

candidate target cell for the PS handover.

Managed Object

External Neighbor Cell


0..63

Value Range and Step

Step: 1

Unit

None

Default Value

35

Default Value
Configuration Reason

Usually -75 dBm can ensure the success of handover.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

5-579
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->PSHOC Parameter
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.3.16 N of handovering to TDD by RSCP (HoRSCP_N_TDD_PS)


Full Name

N of handovering to TDD by RSCP

Abbreviation

HoRSCP_N_TDD_PS

3GPP Name

Internal

3GPP Reference

None
There are at least HoRSCP_N_TDD_PS RSCP average values are reserved for an adjacent UTRAN cell in BSC. At least HoRSCP_P_TDD_PS
of HoRSCP_N_TDD_PS latest RSCP average values is not lower than
the sum of HoRSCPThsTDD_PS and HoRSCPOffset3G_PS, the PS handover from GSM to UTRAN can be triggered. This adjacent cell is the

Description

candidate target cell for the PS handover.

Managed Object

External Neighbor Cell


0..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

To ensure the correct and quick handover, it is recommended to set

Configuration Reason

this parameter 4.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

5-580
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.5.3.17 P of handovering to TDD by RSCP (HoRSCP_P_TDD_PS)


Full Name

P of handovering to TDD by RSCP

Abbreviation

HoRSCP_P_TDD_PS

3GPP Name

Internal

3GPP Reference

None
There are at least HoRSCP_N_TDD_PS RSCP average values are reserved for an adjacent UTRAN cell in BSC. At least HoRSCP_P_TDD_PS
of HoRSCP_N_TDD_PS latest RSCP average values is not lower than
the sum of HoRSCPThsTDD_PS and HoRSCPOffset3G_PS, the PS handover from GSM to UTRAN can be triggered. This adjacent cell is the

Description

candidate target cell for the PS handover.

Managed Object

External Neighbor Cell


0..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

To ensure the correct and quick handover, it is recommended to set

Configuration Reason

this parameter 3.

5-581
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

[External Neighbor Cell]HoRSCP_N_TDD_PS


The value of HoRSCP_P_TDD_PS cannot be higher than the value

Relationship

of HoRSCP_N_TDD_PS.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Handover


Control->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6 UTRAN Cell Control Parameters


UTRAN Cell Control Parameters have four tabs.

5.6.1 Basic Parameters 1


5.6.1.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None

Description

This parameter means the site ID. It cannot be modified.


Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None

5-582
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell Con-

OMC Access Path


Parameter

Modifying

Version
Parameter

trol->Basic parameters 1

None
Modifying

Detail

None

5.6.1.2 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell

5-583
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell Con-

OMC Access Path


Parameter

Modifying

Version
Parameter
Detail

trol->Basic parameters 1

None
Modifying
None

5-584
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.6.1.3 UTRAN BTS ID (S3GBtsId)


Full Name

UTRAN BTS ID

Abbreviation

S3GBtsId

3GPP Name

None

3GPP Reference

None

Description

This parameter means the ID of cell UTRAN control. It cannot be modified.

Managed Object

Cell

Value Range and Step

1~2

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell Con-

OMC Access Path


Parameter

Modifying

Version
Parameter
Detail

trol->Basic parameters 1

None
Modifying
None

5.6.1.4 Channel location of si2quater broadcast (SI2QuaterPos)


Full Name

Channel location of si2quater broadcast

Abbreviation

SI2QuaterPos

3GPP Name

SI2quater_POSITION

5-585
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

3GPP TS44.018 V5.22.0

Description

This parameter indicates channel location of SI2quater broadcast.

Managed Object

Cell
0, 1
0: Broadcast on normal BCCH block;
1: Broadcast on extended BCCH block (AGCH_BLOCK reservation

Value Range and Step

value will be 1)

Unit

None

Default Value

Default Value
Configuration Reason

This is a new feature.

Configuration Rule and

The default value is adopted. If the system is configured with extended

Adjustment Suggestion

BCCH, this parameter is valid.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]BsAgBlkRes

Relationship

When SI2QuaterPos is set as BCCH extended, the radio blocks will be


occupied. The reserved value for BsAgBlkRes should be at least 1.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.1.5 CS measurement type reported by UE (ReportTypeCS)


Full Name

CS measurement type reported by UE

Abbreviation

ReportTypeCS

3GPP Name

REPORT_TYPE

3GPP Reference

3GPP TS 45.008 V5.22.0


5-586

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

It indicates whether a UE uses enhanced measurement report or meaDescription

surement report message.

Managed Object

Cell
0, 1
0: If at least one BSIC is configured for each frequency in BA list, the
UE uses "enhanced measurement report" message; otherwise the UE
uses "normal measurement report".

Value Range and Step

1: UE uses "normal measurement report" message

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Consistent with the those reported by a UE


It is recommended to use the default value. The MS that supports 2/3G
can give the enhanced measurement report. More data from adjacent
cells can be included in the measurement report.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.1.6 Measurement threshold of UE performing UTRAN cell reselection (Qsearch_I)


Full Name

Measurement threshold of UE performing UTRAN cell reselection

Abbreviation

Qsearch_I

3GPP Name

Qsearch_I

5-587
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

3GPP TS 45.008 V5.22.0


When average receiving level RLA_C of the cell falls below (parameter
value: 0 - 6) or higher than (parameter value: 8 - 14) this threshold, UE
starts to measure the UTRAN re-selection cell. "7" means "always and

Description

"15" means "never".

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
0..6: Indicates field strength L = -98 + n*4 dBm;
7: Indicates "always";
8..14: Indicates field strength L = -78 + 4 * (n-8) dbm;

Value Range and Step

15: Indicates never

Unit

None

Default Value

15

Default Value
Configuration Reason

Search is not conducted by default.


Usually in a cell that is expected to interwork with other cells, an MS is
always conducting measurement on other systems. As long as the 3G
system signals meet the residing requirements, handover to this system

Configuration Rule and

can be conducted.

Adjustment Suggestion

If the system is expected to support GSM -> 3G re-selection, this


parameter should be set 7 in the cell configuration for another radio
system, which will improve the re-selection success rate from 2G to 3G.
The value "15" means the measurement function is disabled.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None
5-588

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.6.1.7 Threshold when UE performs search under specialized mode (Qsearch_C)


Full Name

Threshold when UE performs search under specialized mode

Abbreviation

Qsearch_C

3GPP Name

Qsearch_C

3GPP Reference

3GPP TS 45.008 V5.22.0


When average receiving level RLA_C of the cell falls below (parameter
value: 0 - 6) or higher than (parameter value: 8 - 14) this threshold,
UE searches the 3G adjacent cell. "7" means "always and "15" means

Description

"never".

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15
0..6: Indicates field strength L = -98 + n*4 dBm;
7: Indicates "always";
8 ... 14: Indicates field strength L = -78 + 4 * (n-8) dbm;

Value Range and Step

15: Indicates never

Unit

None

Default Value

15

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Search is not conducted by default.


If the system is expected to support GSM -> 3G handover, it is not
recommended to set this parameter 15. If the system is not expected to
support GSM->3G handover, the parameter should be set 15.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Basic parameters 1
Parameter Modifying
Version

None

5-589
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.6.1.8 Initial parameter instead of qsearch_c before UE receiving qsearch_C


(QsearchCInit)
Full Name

Initial parameter instead of qsearch_c before UE receiving qsearch_C

Abbreviation

QsearchCInit

3GPP Name

Qsearch_C_Initial

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter is used to search and measure the cell while MS does not

Description

receive Qsearch_C on SACCH.

Managed Object

Cell
0, 1
0: Qsearch_I parameter;

Value Range and Step

1: always measures.

Unit

None

Default Value

Default Value
Configuration Reason

Use Qsearch_I.

Configuration Rule and


Adjustment Suggestion

It is recommended to use the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 1

Parameter Modifying
Version

None

5-590
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.6.1.9 CS number of same frequency adjacent cells in report (SvrBandRprtCS)


Full Name

CS number of same frequency adjacent cells in report

Abbreviation

SvrBandRprtCS

3GPP Name

SERVING_BAND_REPORTING

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter defines the number of adjacent cells with the same frequency band as the serving cell, which are included in the measurement

Description

report or the strongest cell list (measurement data in a terminal).

Managed Object

Cell

Value Range and Step

0, 1, 2, 3

Unit

None

Default Value

Default Value
Configuration Reason

Recommended value in protocol.

Configuration Rule and


Adjustment Suggestion

It is recommended to use the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Basic parameters 1
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-591
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.6.1.10 Max Number In Adjacent GSM cell (IndexStartEMR)


Full Name

Max Number In Adjacent GSM cell

Abbreviation

IndexStartEMR

3GPP Name

Absolute_Index_Start_EMR

3GPP Reference

3GPP TS 44.018

Description

This parameter indicates the maximum number of GSM adjacent cells.

Managed Object

Cell

Value Range and Step

32, 64

Unit

None

Default Value

32

Default Value
Configuration Reason

Usually 32 adjacent cells are enough.

Configuration Rule and

This parameter should be set according to the radio network planning. It

Adjustment Suggestion

is set 32 or more just when more than 32 adjacent cells are needed.

Change Mode

Offline

Related features

ZGB-02-02-004 Support 64 Neighboring Cells

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Basic parameters 1
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.1.11 CS class of reported quantities of UTRAN adjacent cells (FDDrepQntCS)


Full Name

CS class of reported quantities of UTRAN adjacent cells

Abbreviation

FDDrepQntCS

3GPP Name

FDD_REP_QUANT
5-592

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Reference

3GPP TS 45.008 V5.22.0

Description

It indicates whether an MS uses RSCP or Ec/No to report measurement.

Managed Object

Cell
0, 1
0: RSCP, UE receiving power of CPICH scramble of UTRAN cell, the
unit is dBm;
1: Ec/No, ratio of the receiving power to thermal noise for CPICH

Value Range and Step

scramble of UTRAN cell, the unit is dB.

Unit

None

Default Value

Default Value
Configuration Reason

Ec/No can better reflect the quality of an adjacent cell.

Configuration Rule and


Adjustment Suggestion

The default value is adopted. The value can be adjust to "0" as needed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.1.12 Min Ec/No of UTRAN reselecting cell (FDD_Qmin)


Full Name

Min Ec/No of UTRAN reselecting cell

Abbreviation

FDD_Qmin

3GPP Name

FDD_Qmin

3GPP Reference

3GPP TS 45.008 V5.22.0


5-593

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

When a UTRAN cell is selected in the re-selection process, the value


of Ec/No (code-noise ratio) of this adjacent cell is not lower than the
Description

value of this parameter.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7
0 = -20 dB
1 = -6 dB
2 = -18 dB
3 = -8 dB
4 = -16 dB
5 = -10 dB
6 = -14 dB

Value Range and Step

7 = -12 dB

Unit

None

Default Value

Default Value
Configuration Reason

Middle value
Key parameter in 2G -> 3G cell re-selection. The recommended value
for the parameter is 7(-12dB). The cell re-selection arbitration threshold

Configuration Rule and


Adjustment Suggestion

between WCDMA and GSM/GPRS systems, for example, there should


be the 4 dB distance between the WCDMA parameter SsearchRAT and
the GSM/GPRS parameter FDD_Qmin.
The parameter can be set 7 to raise the success rate of 2G -> 3G
re-selection.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Basic parameters 1
Parameter Modifying
Version

None

5-594
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.6.1.13 CS max number of UTRAN/FDD adjacent cells in measurement report


(FDDMulRatrrptCS)
Full Name

CS max number of UTRAN/FDD adjacent cells in measurement report

Abbreviation

FDDMulRatrrptCS

3GPP Name

XXX_MULTIRAT_REPORTING

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter indicates the maximum number of UTRAN/FDD adjacent
cells included in packet measurement report or strongest cell list. If
UTRAN/FDD adjacent cells are not full, the vacancies are used for
GSM adjacent cells. (If TDD technology is available, the vacancies are

Description

reserved for TDD cells)

Managed Object

Cell

Value Range and Step

0, 1, 2, 3

Unit

None

Default Value

Default Value
Configuration Reason

The successful handover to 3G can be ensured.

Configuration Rule and

If 3G is preferred in 2/3G handover strategy, this parameter can increase

Adjustment Suggestion

the number of 3G adjacent cells.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 1

Parameter Modifying
Version

None

5-595
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.6.1.14 FDD reselection offset (FDD_Qoffset)


Full Name

FDD reselection offset

Abbreviation

FDD_Qoffset

3GPP Name

FDD_Qoffset

3GPP Reference

3GPP TS 45.008 V5.22.0


If a UT adjacent cell has been switched on (The level of a GA adjacent
cell satisfies the requirement of ADDED_Mind), and it satisfies the
requirements of the initiation measurement (Seat_I), a U can be
handed-over to a UT adjacent cell during the re-selection process if the
following three requirements are satisfied:
Received signal code power (RSCP) of this adjacent cell is higher than
average receiving level RLA_C of this cell;
RSCP of the adjacent cell is higher than RLA_C of all adjacent GSM
cells by at least FDD_Qoffset (FDD reselection offset) for more than
5 seconds. FDD_Qoffset of the cell needs 5 dB increment if the cell
is re-selected 15 seconds earlier.
Ec/No (code-noise ratio) of this adjacent cell is not lower than the
designated FDD_Qmin (minimum value of code-noise ratio of UTRAN
re-selected cell).
If more than one UTRAN cell meets the above conditions, select the
cell which has the largest RSCP.
"0" indicates that adjacent cells of this 3G FDD are always selected;
1 = -28 dB;
2 = -24 dB;
...

Description

15 = 28 dB

Managed Object

Cell

Value Range and Step

0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15;

Unit

None

Default Value

Default Value

This parameter adopts the recommended value in the protocol. Offset

Configuration Reason

is not set by default.

5-596
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

"8" means that the offset between GSM signals and 3G signals is "0".
Configuration Rule and
Adjustment Suggestion

However, 3G system frequently occupies 2G frequencies, and the


transmission power loss is big. It is good to set this parameter "0", that
is, 3G signal quality is not considered in the handover, thus the 2G -> 3G
re-selection success rate is raised.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.1.15 RReporting threshold for the Ec/No or RSCP that is not reported
(FDDRprtTho2CS)
Full Name

RReporting threshold for the Ec/No or RSCP that is not reported

Abbreviation

FDDRprtTho2CS

3GPP Name

FDD_REPORTING_THRESHOLD_2
3GPP TS 44.018,

3GPP Reference

3GPP TS 45.008
This is a newly added parameter for GSM/WCDMA inter-operation
during the second phase. It indicates the measurement report threshold
for Ec/No or RSCP parameters.
During the first phase of GSM/WCDMA inter-operation, only the MS is
required to report the signal-noise ratio (Ec/N0) or the measurement
result of the signal strength (RSCP). The MS is required to consider the

Description

two measurement results during the second phase.

Managed Object

Cell

5-597
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0..63
Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default type that is required to report by MS is Ec/No, so the default


value is the RSCP measurement report threshold that is not required
to be reported.

Configuration Rule and

This parameter should be set according to the measurement type

Adjustment Suggestion

reported by the MS.

Change Mode

Offline

Related features

ZGO-02-03-009 GSM/WCDMA Interworking Phase II

Related Parameters

[Cell]FDDRepQntCS
If FDDRepQntCS is 0, this parameter indicates the Ec/No threshold

Relationship

value that does not need to be reported;


If FDDRepQntCS is 1, this parameter indicates the Ec/No threshold
value that does not need to be reported;

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.1.16 Require UE to send UTRAN class-mark change message early (ECSC_3G)


Full Name

Require UE to send UTRAN class-mark change message early

Abbreviation

ECSC_3G

3GPP Name

3G Early Classmark Sending Restriction(44.018)

3GPP Reference

44.018
This parameter indicates whether a UE is required to send UTRAN class-

Description

mark change message early.

5-598
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Cell
Yes, No
NO: Not allow to send "UTRAN class mark change" message
Yes: Both ECSC and UE control whether the UE sends "UTRAN

Value Range and Step

classmark change" message.

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Users decide whether to enable UTRAN CLASSMARK early sending.


This parameter should be enabled when the 2/3G handover is
needed and the core network does not open the process obtained by
CLASSMARK.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Basic parameters 1
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.1.17 A minimum threshold of RSCP for UTRAN FDD cell re-selection


(FDD_RSCPmin)
Full Name

A minimum threshold of RSCP for UTRAN FDD cell re-selection

Abbreviation

FDD_RSCPmin

3GPP Name

FDD_RSCPmin

3GPP Reference

45.008

5-599
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

When this parameter is being broadcast in the system messages, RSCP


threshold in FDD cell re-selection is FDD_RSCPmin min((P_MAX
21 dBm), 3 dB). P_MAX is the maximum transmission power of an MS
under FDD mode.
This parameter is broadcast to MS through SI2quater on BCCH, and is
Description

broadcast to MS through PSI3quater on PBCCH and PACCH.

Managed Object

Cell
0..15
0 = -114 dBm, 1 = -112 dBm, 2 = -110 dBm, 3 = -108 dBm, 4 = -106
dBm, 5 = -104 dBm, 6 = -102 dBm, 7 = -100 dBm, 8 = -98 dBm, 9 = -96
dBm, 10 = -94 dBm, 11 = -92 dBm, 12 = -90 dBm, 13 = -88 dBm, 14
= -86 dBm, 15 = -84 dBm.

Value Range and Step

Default value = -102 dBm.

Unit

None

Default Value

Default Value
Configuration Reason

Under FDD mode, -102 dB RSCP is enough.

Configuration Rule and

If this parameter is set lower, it is easier for MS to handover to FDD

Adjustment Suggestion

cell during cell re-selection.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-600
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.6.1.18 Applies an offset to FDD_Qmin value (FDD_Qmin_Offset)


Full Name

Applies an offset to FDD_Qmin value

Abbreviation

FDD_Qmin_Offset

3GPP Name

FDD_Qmin_Offset

3GPP Reference

45.008
This parameter indicates the FDD_Qmin parameter offset. When FDD
adjacent cell re-selection is being conducted, the Ec/No (code-noise ratio)

Description

is high than or equal to FDD_Qmin - FDD_Qmin_Offset.

Managed Object

Cell
0..7
(2n)dB,
0: 0 dB;
...

Value Range and Step

7: 14 dB

Unit

None

Default Value

Default Value

FDD_Qmincan be indicates the Ec/No requirement for FDD adjacent

Configuration Reason

cell re-selection.

Configuration Rule and

If a 3G adjacent cell is expected to be selected, this parameter should

Adjustment Suggestion

be set high.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-601
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.6.2 Basic Parameters 2


5.6.2.1 CS measurement reporting rate of adjacent cell (ReportRateCS)
Full Name

CS measurement reporting rate of adjacent cell

Abbreviation

ReportRateCS

3GPP Name

REPORTING_RATE

3GPP Reference

45.008
This parameter indicates the frequency for measurement report hand-in
by adjacent cells. Refer to REP_PRIORITY. The cells with low priorities
has a low hand-in frequency. However, there must be one hand-in

Description

in 4 times.

Managed Object

Cell
0, 1
0: normal;

Value Range and Step

1: low

Unit

None

Default Value

Default Value
Configuration Reason

Usually an adjacent cell can have a same frequency.

Configuration Rule and


Adjustment Suggestion

Not recommended to modify the parameter value.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-602
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.6.2.2 MulBndRprtCS (MulBndRprtCS)


Full Name

MulBndRprtCS

Abbreviation

MulBndRprtCS

3GPP Name

MULTIBAND_REPORTING

3GPP Reference

45.008
This parameter is to control the number of reports of different adjacent

Description

cells except the serving cell.

Managed Object

Cell
0, 1, 2, 3
0: MS reports the survey results of six known and allowed adjacent cells
with the strongest NCC according to the signal intensity, regardless of
which frequency band adjacent cells are in;
1: MS reports the survey result of one adjacent cell with the strongest
signals in the frequency bands (excluding that of local cell) in adjacent
cell table. In the remained locations, MS reports the adjacent cells
in the frequency band of local cell. If there are still more remained
locations, MS reports the second strongest adjacent cell, regardless
of their frequency bands;
2: MS reports the measurement result of two adjacent cells with
strongest signal in the frequency bands in adjacent cell list (excluding
frequency band of serving cell). In the remained locations, MS reports
the adjacent cells in the frequency band of local cell. If there are still
more remained locations, MS reports the second strongest adjacent cell,
regardless of their frequency bands;
3: MS reports the measurement result of three adjacent cells with
strongest signal in the frequency bands in adjacent cell list (excluding
frequency band of serving cell). In the remaining locations, MS reports
the adjacent cells in the frequency band of local cell. If there are still
more locations remaining, MS reports the second strongest adjacent

Value Range and Step

cell, regardless of their frequency bands.

Unit

None

Default Value

0
In a dual-frequency environment, the parameter can be set 0 to limit the

Default Value

traffic bearing, that is, the hand-in should base on the signal strength,

Configuration Reason

and adjacent cells in different frequency bands should be treat with a


same priority.
In a dual-frequency environment, the 900M cells can be set to report

Configuration Rule and


Adjustment Suggestion

as many 1800M cells as possible to make the handover conducted in


1800M frequency. This configuration is good to balance the traffic and
lower and reduce congestion. However, the success ratio of handover,
call drop ratio and coverage ratio might be affected.
5-603

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Basic parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.3 CS offset which is added when UE reports rxlev value (ScaleOrdCS)


Full Name

CS offset which is added when UE reports rxlev value

Abbreviation

ScaleOrdCS

3GPP Name

SCALE_ORD

3GPP Reference

45.008
This parameter defines the added offset when UE reports signal field
intensity. If the field intensity of a certain GSM adjacent cell is n dBm, UE
will map n+ ScaleOrdCS to the original value corresponding to n when
mapping to RXLEV (0 .. 63). It applies only in the case that "enhanced
measurement report" message is used.
If the field intensity of adjacent cell exceeds -48 dBm, the real value
can be reported by setting this parameter. UE includes the SCALE
value when it reports "enhance measurement report" message. If
SCALE_ORD = 2, UE uses the value of cell that reports the best signal

Description

level.

Managed Object

Cell
0, 1, 2
0: 0 dB;
1: 10 dB;

Value Range and Step

2: Automatic, determined by UE

5-604
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

None

Default Value

Default Value
Configuration Reason

Values other than 0 can be used.

Configuration Rule and


Adjustment Suggestion

This parameter can be set 1 or 2 to view the real level.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Basic parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.4 TDD reselection offset (TDD_Qoffset)


Full Name

TDD reselection offset

Abbreviation

TDD_Qoffset

3GPP Name

TDD_Qoffset

3GPP Reference

45.008(V8.3.0)
This parameter indicates the RSCP threshold when the an MS is handed-

Description

over to a 3G TDD cell.

Managed Object

Cell
0 = -105 dBm, 1 = -102 dBm, 2=-99 dBm, 3 = -96 dBm, 4 = -93 dBm, 5
= -90 dBm, 6 = -87 dBm, 7 = -84 dBm, 8 = -81 dBm, 9 = -78 dBm, 10 =
-75 dBm, 11 = -72 dBm, 12 = -69 dBm, 13 = -66 dBm, 14 = -63 dBm, 15

Value Range and Step

= -60 dBm.

Unit

None
5-605

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value
Configuration Reason

When the RSCP of a TDD cell is -81 dBm, the signals are strong.

Configuration Rule and

This parameter can be set lower if the cell re-selection to a TDD cell

Adjustment Suggestion

is expected to be easier.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.5 CS MAX number of UTRAN/TDD adjacent cells in measurement report


(TDDMulRatRrptCS)
Full Name

CS MAX number of UTRAN/TDD adjacent cells in measurement report

Abbreviation

TDDMulRatRrptCS

3GPP Name

XXX_MULTIRAT_REPORTING

3GPP Reference

45.008
This parameter indicates the maximum number of UTRAN/TDD adjacent
cells included in measurement report or strongest cell list. If UTRAN/TDD
adjacent cells are not full, the vacancies are used for GSM adjacent cells

Description

(If FDD technology is supported, remained part is given to FDD cell).

Managed Object

Cell

Value Range and Step

0, 1, 2, 3

Unit

None

Default Value

2
5-606

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value
Configuration Reason

Hand in 2 TDD adjacent cells for selection.

Configuration Rule and

If a user is expected to stay in TDD network, the parameter can be set

Adjustment Suggestion

higher.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.6 CS UE report invalid cell level allowed (InvldBSICRprtCS)


Full Name

CS UE report invalid cell level allowed

Abbreviation

InvldBSICRprtCS

3GPP Name

INVALID_BSIC_REPORTING

3GPP Reference

45.008
NCC in BSIC of some GSM cells are allowed, but BCC is invalid (that is,
the radio system does not have adjacent cells corresponding to BCC).
This parameter indicates whether the system allows UE to report field

Description

intensity of such cells (NCC is allowed but BCC us invalid).

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

BCC does not know the adjacent cell, which is not configured in BSC.

Configuration Reason

The cell cannot be the target during handover process.


5-607

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

This parameter is not set as "Yes".

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.7 CS UE search UTRAN adjacent cell in BSIC decoding frame indication


(SearchPrioCS3G)
Full Name

CS UE search UTRAN adjacent cell in BSIC decoding frame indication

Abbreviation

SearchPrioCS3G

3GPP Name

3G_SEARCH_PRIO

3GPP Reference

45.008
This parameter indicates whether to allow UE to search UTRAN adjacent
cells in the frame where BSIC decoding is needed. If allowed, UE can

Description

use at most 25 frames for search in 13 seconds.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

Searching for GSM adjacent cells.

Configuration Rule and

If a user is expected to stay in 3G network, this parameter should be

Adjustment Suggestion

set as "Yes".
5-608

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Basic parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.8 GSM850M Adjacent cell reporting signal level Offset (RprtOffsetCS850)


Full Name

GSM850M Adjacent cell reporting signal level Offset

Abbreviation

RprtOffsetCS850

3GPP Name

XXX_REPORTING_OFFSET

3GPP Reference

45.008

Description

An offset can be added to a 850 M GSM adjacent cell.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7

Value Range and Step

0..7: corresponding to 0..42 dB, each level 6 dB

Unit

None

Default Value

Default Value
Configuration Reason

No configuration on the frequency bands and access technologies.

Configuration Rule and

This parameter should be set higher if more handovers to GSM850M

Adjustment Suggestion

adjacent cells are expected to be conducted.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

5-609
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.9 GSM850M Adjacent cell reporting signal level Threshold (RprtThoCS850)


Full Name

GSM850M Adjacent cell reporting signal level Threshold

Abbreviation

RprtThoCS850

3GPP Name

XXX_REPORTING_THRESHOLD

3GPP Reference

45.008
The GSM 850 M adjacent cells can be reported only when signal level
in the cell is higher than or equal to RprtThoCS850 (dimensionless,
corresponding to RXLEV portion in measurement report, different
mapping relationship for different RXLEV).
Whether it can be reported in certain period depends on signal level,

Description

RepPrioCS, MulBndRprtCS and RprtOffsetCS850.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7
0: always;
1..6: corresponding to 6..36, each level 6;

Value Range and Step

7: never

Unit

None

Default Value

Default Value

The measurement value is not limited during the report of GSM 850 M

Configuration Reason

adjacent cells.

Configuration Rule and

If more GSM 850 M adjacent cells need to be reported, the threshold

Adjustment Suggestion

should be set low; otherwise it should be set high.

Change Mode

Offline

5-610
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Basic parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.10 GSM900M Adjacent cell reporting signal level Offset (RprtOffsetCS900)


Full Name

GSM900M Adjacent cell reporting signal level Offset

Abbreviation

RprtOffsetCS900

3GPP Name

XXX_REPORTING_OFFSET

3GPP Reference

45.008

Description

An offset can be added to a 900 M GSM adjacent cell.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7

Value Range and Step

0..7: corresponding to 0..42 dB, each level 6 dB

Unit

None

Default Value

Default Value
Configuration Reason

No configuration on the frequency bands and access technologies.

Configuration Rule and

This parameter should be set higher if more handovers to GSM900M

Adjustment Suggestion

adjacent cells are expected to be conducted.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None
5-611

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.11 GSM900M Adjacent cell reporting signal level Threshold (RprtThoCS900)


Full Name

GSM900M Adjacent cell reporting signal level Threshold

Abbreviation

RprtThoCS900

3GPP Name

XXX_REPORTING_THRESHOLD

3GPP Reference

45.008
The GSM 900 M adjacent cells can be reported only when signal level
in the cell is higher than or equal to RprtThoCS900 (dimensionless,
corresponding to RXLEV portion in measurement report, different
mapping relationship for different RXLEV).
Whether it can be reported in certain period depends on signal level,

Description

RepPrioCS, MulBndRprtCS and RprtOffsetCS900.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7
0: always;
1..6: corresponding to 6..36, each level 6;

Value Range and Step

7: never

Unit

None

Default Value

Default Value

The measurement value is not limited during the report of GSM 900 M

Configuration Reason

adjacent cells.

Configuration Rule and

If more GSM 900 M adjacent cells need to be reported, the threshold

Adjustment Suggestion

should be set low; otherwise it should be set high.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

5-612
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->Basic parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.12 GSM1800M Adjacent cell reporting signal level Offset (RprtOffsetCS1800)


Full Name

GSM1800M Adjacent cell reporting signal level Offset

Abbreviation

RprtOffsetCS1800

3GPP Name

XXX_REPORTING_OFFSET

3GPP Reference

45.008

Description

An offset can be added to a 180000 M GSM adjacent cell.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7

Value Range and Step

0..7: corresponding to 0..42 dB, each level 6 dB

Unit

None

Default Value

Default Value
Configuration Reason

No configuration on the frequency bands and access technologies.

Configuration Rule and

This parameter should be set higher if more handovers to GSM900M

Adjustment Suggestion

adjacent cells are expected to be conducted.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um
5-613

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.13 GSM1800M Adjacent cell reporting signal level Threshold (RprtThoCS1800)


Full Name

GSM1800M Adjacent cell reporting signal level Threshold

Abbreviation

RprtThoCS1800

3GPP Name

XXX_REPORTING_THRESHOLD

3GPP Reference

45.008
The GSM 1800 M adjacent cells can be reported only when signal level
in the cell is higher than or equal to RprtThoCS1800 (dimensionless, corresponding to RXLEV portion in measurement report, different mapping
relationship for different RXLEV). As to whether it can be reported in certain period, it also depends on signal level, RepPrioPS, MulBndRprtPS

Description

and RprtOffsetPS900.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7
0: always;
1..6: corresponding to 6..36, each level 6;

Value Range and Step

7: never

Unit

None

Default Value

Default Value

The measurement value is not limited during the report of GSM 1800 M

Configuration Reason

adjacent cells.

Configuration Rule and

If more GSM 1800 M adjacent cells need to be reported, the threshold

Adjustment Suggestion

should be set low; otherwise it should be set high.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

5-614
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.14 GSM1900M Adjacent cell reporting signal level Offset (RprtOffsetCS1900)


Full Name

GSM1900M Adjacent cell reporting signal level Offset

Abbreviation

RprtOffsetCS1900

3GPP Name

XXX_REPORTING_OFFSET

3GPP Reference

45.008

Description

An offset can be added to a 1900 M GSM adjacent cell.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7

Value Range and Step

0..7: corresponding to 0 .. 42 dB, each level 6 dB

Unit

None

Default Value

Default Value
Configuration Reason

No configuration on the frequency bands and access technologies.

Configuration Rule and

This parameter should be set higher if more handovers to GSM900M

Adjustment Suggestion

adjacent cells are expected to be conducted.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

5-615
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.15 GSM1900M Adjacent cell reporting signal level Threshold (RprtThoCS1900)


Full Name

GSM1900M Adjacent cell reporting signal level Threshold

Abbreviation

RprtThoCS1900

3GPP Name

XXX_REPORTING_THRESHOLD

3GPP Reference

45.008
The GSM 1900 M adjacent cells can be reported only when signal level
in the cell is higher than or equal to RprtThoCS1900 (dimensionless,
corresponding to RXLEV portion in measurement report, different
mapping relationship for different RXLEV).
As to whether it can be reported in certain period, it also depends on

Description

signal level, RepPrioCS, MulBndRprtCS and RprtOffsetCS1900.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7
0: always;
1..6: corresponding to 6..36, each level 6;

Value Range and Step

7: never

Unit

None

Default Value

Default Value

The measurement value is not limited during the report of GSM 1900 M

Configuration Reason

adjacent cells.

Configuration Rule and

If more GSM 1900 M adjacent cells need to be reported, the threshold

Adjustment Suggestion

should be set low; otherwise it should be set high.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None
5-616

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.16 UTRAN/FDD Adjacent cell reporting signal level Offset (FDDRprtOffsetCS)


Full Name

UTRAN/FDD Adjacent cell reporting signal level Offset

Abbreviation

FDDRprtOffsetCS

3GPP Name

XXX_REPORTING_OFFSET

3GPP Reference

45.008
An offset can be added to an FDD adjacent cell when the priority sequence

Description

of the hand-in adjacent cells are determined.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7

Value Range and Step

0..7: corresponding to 0..42 dB, each level 6 dB

Unit

None

Default Value

Default Value
Configuration Reason

No configuration on the frequency bands and access technologies.

Configuration Rule and

This parameter should be set higher if more handovers to FDD adjacent

Adjustment Suggestion

cells are expected to be conducted.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

5-617
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.17 UTRAN/FDD Adjacent cell reporting signal level Threshold (FDDRprtThoCS)


Full Name

UTRAN/FDD Adjacent cell reporting signal level Threshold

Abbreviation

FDDRprtThoCS

3GPP Name

XXX_REPORTING_THRESHOLD

3GPP Reference

45.008
When reporting to UTRAN/FDD adjacent cells, only when signal level in
the cell is higher than or equal to FDDRprtThoCS (dimensionless, corresponding to RXLEV portion in measurement report, different mapping
relationship for different RXLEV), it can be reported. As to whether it can
be reported in certain period, it also depends on signal level, RepPrioCS,

Description

FDDMulRatRrptCS and FDDRprtOffsetCS.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7
0: always;
1..6: corresponding to 6 .. 36, each level 6;

Value Range and Step

7: never

Unit

None

Default Value

Default Value
Configuration Reason

FDD

Configuration Rule and

If more FDD adjacent cells are needed, the threshold should be set

Adjustment Suggestion

low; otherwise it should be set high.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None
5-618

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.18 UTRAN/TDD Adjacent cell reporting signal level Offset (TDDRprtOffsetCS)


Full Name

UTRAN/TDD Adjacent cell reporting signal level Offset

Abbreviation

TDDRprtOffsetCS

3GPP Name

XXX_REPORTING_OFFSET

3GPP Reference

45.008
An offset can be added to an TDD adjacent cell when the priority sequence

Description

of the hand-in adjacent cells are determined.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7

Value Range and Step

0..7: corresponding to 0..42 dB, each level 6 dB

Unit

None

Default Value

Default Value
Configuration Reason

No configuration on the frequency bands and access technologies.

Configuration Rule and

This parameter should be set higher if more handovers to TDD adjacent

Adjustment Suggestion

cells are expected to be conducted.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

5-619
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.2.19 UTRAN/TDD Adjacent cell reporting signal level Threshold (TDDRprtThoCS)


Full Name

UTRAN/TDD Adjacent cell reporting signal level Threshold

Abbreviation

TDDRprtThoCS

3GPP Name

XXX_REPORTING_THRESHOLD

3GPP Reference

45.008
When reporting to UTRAN/TDD adjacent cells, only when signal level in
the cell is higher than or equal to TDDRprtThoCS (dimensionless, corresponding to RXLEV portion in measurement report, different mapping
relationship for different RXLEV), it can be reported. Whether it can be
reported in certain period depends on signal level, RepPrioCS, TDDMul-

Description

RatRrptCS and TDDRprtOffsetCS.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7
0: always;
1..6: corresponding to 6..36, each level 6;

Value Range and Step

7: never

Unit

None

Default Value

Default Value

The measurement value is not limited during the report of TDD adjacent

Configuration Reason

cells.

Configuration Rule and

If more TDD adjacent cells need to be reported, the threshold should be

Adjustment Suggestion

set low; otherwise it should be set high.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None
5-620

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->Basic parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.3 GPRS Parameters 1


5.6.3.1 PS offset which is added when UE reports RXLEV value (ScaleOrdPS)
Full Name

PS offset which is added when UE reports RXLEV value

Abbreviation

ScaleOrdPS

3GPP Name

SCALE_ORD

3GPP Reference

3GPP TS 45.008 V6.19.0


The parameter SCALE_ORD indicates the RXLEV offset is reported
through PACKET ENHANCED MEASUREMENT REPORT message.
The signal level is mapped to RXLEVaccording to the following
correlations (0 .. 63):
RXLEV 0 = less than 110 dBm + SCALE.
RXLEV 1 = 110 dBm + SCALE to 109 dBm + SCALE.
RXLEV 2 = 109 dBm + SCALE to 108 dBm + SCALE.
:
:
RXLEV 62 = 49 dBm + SCALE to 48 dBm + SCALE.
RXLEV 63 = greater than 48 dBm + SCALE.
SCALE value is set by the SCALE_ORD parameter in PACKET CELL
CHANGE ORDER and PACKET MEASUREMENT ORDER.
MS indicates the SCALE value in PACKET ENHANCED
MEASUREMENT REPORT message.
This parameter defines the added offset when UE reports signal field
intensity. If the actual field intensity of a GSM adjacent cell is n dBm, the
"n + SCALE_ORD" should be mapped to the original "n" value when UE
is mapped to RXLEV (0 .. 63). It applies only in the case that "PACKET

Description

ENHANCED MEASUREMENT REPORT" message is used.


5-621

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If the field intensity of adjacent cell exceeds -48 dBm, the real value can
be reported by setting this parameter. UE includes the SCALE value
when it reports "PACKET ENHANCED MEASUREMENT REPORT"
message. If SCALE_ORD=2, UE will use a minimum offset value for
report a cell with the strongest signal level.
Managed Object

Cell
(0, 1, 2)
0: 0 dB;
1: 10 dB;

Value Range and Step

2: Automatic, determined by UE

Unit

None

Default Value

Default Value

Only used for enhanced measurement report. Not applied yet. The

Configuration Reason

default offset value is 0.


At least one BSIC is allocated for each frequency point, and MS has
received the BSIC from all adjacent cells. If the measurement type
parameter ReportTypePS is 0, MS will use the enhanced measurement
report to measure the adjacent cell. When ScaleOrdPS parameter is
0, there is no offset; when the parameter is 1, the offset is 10 dB, the

Configuration Rule and


Adjustment Suggestion

reported level range is -100 dB .. -38 dB, that is, the level mapped
during 0 .. 63 will raise by10dB; when the parameter is 2, SCALE value
will be the minimum offset value that can be reported by the strongest
adjacent cell. For example, if the strongest signal intensity in an adjacent
cell is -30 dB, the SCALE value is 18. Then all the adjacent cells can
be reported. Usually no offset is needed. The parameter should be 0.
For the adjacent cells with special signal strength, this parameter can
be adjusted to 1 or 2.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

5-622
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.3.2 PS measurement type reported by UE (ReportTypePS)


Full Name

PS measurement type reported by UE

Abbreviation

ReportTypePS

3GPP Name

REPORT_TYPE

3GPP Reference

3GPP TS 44.060 V5.19.0


The parameter REPORT_TYPE determines whether MS will use
PACKET MEASUREMENT REPORT or PACKET ENHANCED
MEASUREMENT REPORT message to report (NC) measurement
report. The parameter information is passed to MS through PACKET
CELL CHANGE ORDER or PACKET MEASUREMENT ORDER
message. 0: If each frequency in BA (GPRS) list is configured with at
least one BSIC, PACKET ENHANCED MEASUREMENT REPORT is
used; otherwise PACKET MEASUREMENT REPORT is used.

Description

1: Uses PACKET MEASUREMENT REPORT

Managed Object

Cell

Value Range and Step

(0, 1)

Unit

None

Default Value

Default Value

Usually PACKET MEASUREMENT REPORT is used. The default value

Configuration Reason

recommended by protocol is 1.
At least one BSIC is allocated for each frequency point, and MS has
received the BSIC from all adjacent cells. If the measurement type

Configuration Rule and

parameter ReportTypePS is 0, MS will use the enhanced measurement

Adjustment Suggestion

report to measure the adjacent cell. If the above conditions are not
met, it is recommended to set the parameter as 1, using the common
measurement report.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

5-623
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.3.3 PS number of same frequency adjacent cells in report (SvrBandRprtPS)


Full Name

PS number of same frequency adjacent cells in report

Abbreviation

SvrBandRprtPS

3GPP Name

SERVING_BAND_REPORTING

3GPP Reference

3GPP TS 45.008 V6.19.0


The number reported by the adjacent cells in a same frequency band
indicates the maximum number of adjacent cells in the same frequency
band with GSM serving cell. The parameter information is passed to MS
through PACKET CELL CHANGE ORDER or PACKET MEASUREMENT

Description

ORDER message.

Managed Object

Cell

Value Range and Step

(0, 1, 2, 3)

Unit

None

Default Value

Default Value

Refer to the CS configuration of reported number of adjacent cells in

Configuration Reason

a same frequency.

Configuration Rule and

Refer to the CS configuration principle of reported number of adjacent

Adjustment Suggestion

cells in a same frequency.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

0
5-624

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.3.4 PS measurement reporting rate of adjacent cell (ReportRatePS)


Full Name

PS measurement reporting rate of adjacent cell

Abbreviation

ReportRatePS

3GPP Name

REPORTING_RATE

3GPP Reference

3GPP TS 45.008 V6.19.0


The parameter information is passed to MS through PACKET CELL
CHANGE ORDER or PACKET MEASUREMENT ORDER message. The
cells with lower priorities has a lower hand-in frequency. However, there
must be one hand-in in 4 consecutive measurement reports. The cells

Description

with high priority hand in the measurement reports in time.

Managed Object

Cell
(0, 1)
0: normal

Value Range and Step

1: lowRefer to RepPrioPS

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The recommended in protocol ensures the proper hand-in.


Usually every adjacent cell is treated with the same priority. When
the adjacent cells with low priority need hand-in in low frequency, the
parameter ReportRatePS should be set 1.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

[Cell]RepPrioPS

5-625
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The parameter RepPrioPS configures every adjacent cell; the parameter


Relationship

RepRatePS configures the current cell. The two parameters determines


the measurement report hand-in frequency in the adjacent cell.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS parameters 1
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.3.5 Measurement threshold of UE performing GPRS UTRAN cell_0/Measurement


threshold of UE performing_1 GPRS UTRAN cell (Qsearch_P_0/Qsearch_P_1)
Measurement threshold of UE performing GPRS UTRAN cell_0/MeasureFull Name

ment threshold of UE performing_1 GPRS UTRAN cell

Abbreviation

Qsearch_P_0/Qsearch_P_1

3GPP Name

Qsearch_P

3GPP Reference

3GPP TS 45.008 V6.19.0


Qsearch_P starts the measurement of 3G adjacent cell threshold for UE.
The parameter informs UE through PACKET MEASUREMENT ORDER
or PACKET CELL CHANGE ORDER message. 3G cells will be searched
when signal level is lower than threshold 0 ~ 7 (corresponding to -98,
-94, ..., , -74dBm), threshold 7 indicates "always search"; or search while
above threshold 8~15 (-78, -74, ..., -54 dBm), threshold 15 indicates never

Description

search.

Managed Object

Cell
0 ..15
0..7 (corresponding to -98, -94, ... , -74 dBm, always)

Value Range and Step

8..15 (-78, -74, ... , -54 dBm, never)

Unit

None

Default Value

15

Default Value

The initiated value is set as W/TD not enabled. Not start the

Configuration Reason

measurement.

5-626
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter is not sent in SI2quater. Even it is broadcast in


SI2quater, the Qsearch_P in SI2quater takes effect only after the PMO
or PCCO message including adjacent cell information is sent on PACCH.
Qsearch_P is also included in a PMP or PCCO message. Therefore,
this parameter is sent to MS in transmission state. In idle status, an MS
still uses the Qsearch_I parameter. If an MS is always being expected to
Configuration Rule and

conduct 3G adjacent cell measurement, the parameter should be set 7; if

Adjustment Suggestion

an MS is not expected to 3G adjacent cell measurement, the parameter


should be set 15. If the measurement is expected to be conducted
when the level is lower than the threshold, the parameter should be set
1 .. 6; when the measurement is expected to be conducted when the
level is higher than the threshold, the parameter should be set 8 .. 14.
Usually the packet services are expected to choose 3G network. The
parameter should be set 7.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.3.6 FDD GPRS reselection offset_0/FDD GPRS reselection offset_1


(FDD_GPRS_Qoffset_0/FDD_GPRS_Qoffset_1)
Full Name

FDD GPRS reselection offset_0/FDD GPRS reselection offset_1

Abbreviation

FDD_GPRS_Qoffset_0/FDD_GPRS_Qoffset_1

3GPP Name

FDD_GPRS_Qoffset

3GPP Reference

3GPP TS 45.008 V6.19.0

5-627
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

(PBCCH parameter) FDD GPRS re-selection offset indicates when cell


is re-selected to 3G FDD adjacent cell, its RSCP shall be higher than the
least offset of RLA_P in the serving GSM adjacent cells that are suitable
to reside. A one-dimensional array is used to indicate packet idle state
and packet transmission state parameters. When a UE is handed over
to a 3G adjacent cell, the following re-selection standards should be met
for longer than 5 seconds.
CPICH Ec/No > = FDD_ Qmin FDD_Qmin_Offset
CPICH RSCP > RLA_P(s+n) + _FDD_GPRS_Qoffset
CPICH RSCP > = FDD_RSCP_Threshold
The parameter FDD_GPRS_Qoffset, FDD_Qmin and FDD_Qmin_Offset
are broadcast to an MS through packet system messages PSI3quater.
RLA_P(s+n) is the average signal intensity of a serving cell and n GSM
adjacent cells with the strongest signal intensity.
FDD_RSCP_Threshold = FDD_RSCPmin min((P_MAX 21 dBm), 3
dB) If FDD_RSCPmin is broadcast in the system messages in a serving
cell; otherwise
FDD_RSCP_Threshold = Qrxlevmin + Pcompensation + 10 dB
0indicates always selecting adjacent cells of this 3G FDD;
1 = -28 dB;
2 = -24 dB;
...
Description

15 = 28 dB

Managed Object

Cell
0 ..15
0: indicates always selecting adjacent cells of this 3G FDD;
1 = -28 dB;
2 = -24 dB;
...

Value Range and Step

15 = 28 dB

Unit

None

Default Value

Default Value
Configuration Reason

The offset is 0 dBm, which is the recommended value in the protocol.

Configuration Rule and

the parameter should be set 0. It is easier to access the cells if the

Adjustment Suggestion

parameter is set smaller. If the strategy is "prefer 3G network", the

If a user always expects to access the adjacent cells of this 3G FDD,

parameter should be set 0.


Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

5-628
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.3.7 TDD GPRS reselection offset_0/TDD GPRS reselection offset_1


(TDD_GPRS_Qoffset_0/TDD_GPRS_Qoffset_1)
Full Name

TDD GPRS reselection offset_0/TDD GPRS reselection offset_1

Abbreviation

TDD_GPRS_Qoffset_0/TDD_GPRS_Qoffset_1

3GPP Name

TDD_GPRS_Qoffset

3GPP Reference

3GPP TS 45.008 V6.19.0


(PBCCH parameter) TDD GPRS re-selection offset indicates when cell
is re-selected to 3G TDD adjacent cell, its RSCP shall be higher than the
least offset of RLA_P in the serving GSM adjacent cells that are suitable
to reside. A one-dimensional array is used to indicate packet idle state
and packet transmission state parameters. When a UE is handed over
to a 3G adjacent cell, the following re-selection standards should be met
for longer than 5 seconds.
CPICH RSCP > RLA_P(s+n) + _FDD_GPRS_Qoffset
The parameter TDD_GPRS_Qoffset is broadcast to an MS through
packet system messages PSI3quater.
RLA_P(s+n) is the average signal intensity of a serving cell and n GSM
adjacent cells with the strongest signal intensity.
0indicates always selecting adjacent cells of this 3G TDD;
1 = -28 dB;
2 = -24 dB;
...
15 = 28 dB, and the above GPRS_TDD_Qoffset arbitration criteria was
modified to be absolute value arbitration in 3GPP 2009, as follow: RSCP
> = TDD_GPRS_Qoffset, that is , the signal field intensity is higher than

Description

or equal to TDD_GPRS_Qoffset and this state is longer than 5 seconds.


5-629

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Then the re-selection is triggered. In the absolute value arbitration


criteria, TDD_GPRS_Qoffset value corresponds with the signal intensity
as the following: 0 = -105 dBm, 1 = -102 dBm, 2=-99 dBm, 3 = -96 dBm,
4 = -93 dBm, 5 = -90 dBm, 6 = -87 dBm, 7 = -84 dBm, 8 = -81 dBm, 9 =
-78 dBm, 10 = -75 dBm, 11 = -72 dBm, 12 = -69 dBm, 13 = -66 dBm, 14
= -63 dBm, 15 = -60 dBm
Managed Object

Cell
Old mode: 0 .. 15
0: indicates "always select adjacent cells of this 3G TDD";
1 = -28 dB;
2 = -24 dB;
...
15 = 28 dB;
The value range under the new work mode: 0 .. 15
0 = -105 dBm, 1 = -102 dBm, 2 = -99 dBm, 3 = -96 dBm, 4 = -93 dBm,
5 = -90 dBm, 6 = -87 dBm, 7 = -84 dBm, 8 = -81 dBm, 9 = -78 dBm,
10 = -75 dBm, 11 = -72 dBm, 12 = -69 dBm, 13 = -66 dBm, 14 = -63

Value Range and Step

dBm, 15 = -60 dBm

Unit

None

Default Value

Default Value
Configuration Reason

The offset is 0dBm (The recommended value in protocol is 5, -90dBm).


For MS under old work mode, the parameter is regarded as a relative
offset. If a user always expects to access the adjacent cells of this 3G

Configuration Rule and


Adjustment Suggestion

TDD, the parameter should be set 0. It is easier to access the cells


if the parameter is set smaller. If the strategy is "prefer 3G network",
the parameter should be set 0. For MS under new work mode, the
parameter is regarded as an absolute threshold. It is easier to access
the cells if the parameter is set smaller.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-630
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.3.8 PS MIN Ec/No of UTRAN reselecting cell_0/PS MIN Ec/No of UTRAN reselecting
cell_1 (FDD_QminPS_0/FDD_QminPS_1)
PS MIN Ec/No of UTRAN reselecting cell_0/PS MIN Ec/No of UTRAN
Full Name

reselecting cell_1

Abbreviation

FDD_QminPS_0/FDD_QminPS_1

3GPP Name

FDD_Qmin

3GPP Reference

3GPP TS 45.008 V6.19.0


The minimum code-noise ratio in (PBCCH parameter) UTRAN cell
re-selection indicates that when a 3G cell is selected in the re-selection
process, the value of Ec/No (code-noise ratio) of this adjacent cell is not
lower than the value of this parameter. A one-dimensional array is used
to indicate packet idle state and packet transmission state parameters.
When a UE is handed over to a 3G adjacent cell, the following
re-selection standards should be met for longer than 5 seconds.
CPICH Ec/No > = FDD_ Qmin FDD_Qmin_Offset
CPICH RSCP > RLA_P(s+n) + _FDD_GPRS_Qoffset
CPICH RSCP > = FDD_RSCP_Threshold
The parameter FDD_GPRS_Qoffset, FDD_Qmin and FDD_Qmin_Offset
are broadcast to an MS through packet system messages PSI3quater.
RLA_P(s+n) is the average signal intensity of a serving cell and n GSM
adjacent cells with the strongest signal intensity.
FDD_RSCP_Threshold = FDD_RSCPmin min((P_MAX 21 dBm), 3
dB) If FDD_RSCPmin is broadcast in the system messages in a serving
cell; otherwise
FDD_RSCP_Threshold = Qrxlevmin + Pcompensation + 10 dB
0 = -20 dB, 1 = -6 dB, 2 = -18 dB, 3 = -8 dB, 4 = -16 dB, 5 = -10 dB, 6 =

Description

-14 dB, 7= -12 dB.

Managed Object

Cell

5-631
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The value range is 0..7


0 = -20 dB;
1 = -6 dB
2 = -18 dB
3 = -8 dB
4 = -16 dB
5 = -10 dB
6 = -14 dB
Value Range and Step

7 = -12 dB

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

Middle value
If the correlated Ec/Io is higher, it is harder to handover to the 3G
FDD cell during re-selection. The correlation between the value and
re-selection is not a linear relationship.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.3.9 Offset of FDD_QminPS_0/Offset of FDD_QminPS_1 (FDD_Qmin_OffsetPS_0/FD


D_Qmin_OffsetPS_1)
Full Name

Offset of FDD_QminPS_0/Offset of FDD_QminPS_1

Abbreviation

FDD_Qmin_OffsetPS_0/FDD_Qmin_OffsetPS_1

5-632
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

FDD_Qmin_Offset

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the offset of the PBCCH parameter FDD_Qmin.
A one-dimensional array is used to indicate packet idle state and packet
transmission state parameters. When a UE is handed over to a 3G
adjacent cell, the following re-selection standards should be met for
longer than 5 seconds.
CPICH Ec/No > = FDD_ Qmin FDD_Qmin_Offset
CPICH RSCP > RLA_P(s+n) + _FDD_GPRS_Qoffset
CPICH RSCP > = FDD_RSCP_Threshold
The parameter FDD_GPRS_Qoffset, FDD_Qmin and FDD_Qmin_Offset
are broadcast to an MS through packet system messages PSI3quater.
RLA_P(s+n) is the average signal intensity of a serving cell and n GSM
adjacent cells with the strongest signal intensity.
FDD_RSCP_Threshold = FDD_RSCPmin min((P_MAX 21 dBm), 3
dB) If FDD_RSCPmin is broadcast in the system messages in a serving
cell; otherwise
FDD_RSCP_Threshold = Qrxlevmin + Pcompensation + 10 dB
0 = 0 dB, 1 = 2 dB, 2 = 4 dB, 3 = 6 dB, 4 = 8 dB, 5 = 10 dB, 6 = 12

Description

dB, 7= 14 dB.

Managed Object

Cell
The value range is 0..7
0 = 0 dB
1 = 2 dB
2 = 4 dB
3 = 6 dB
4 = 8 dB
5 = 10 dB
6 = 12 dB

Value Range and Step

7 = 14 dB

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The offset is 0dB


If the offset value is higher, it is easier to handover to a 3G FDD cell
during re-selection. If the offset value is lower, it is harder to handover to
a 3G FDD cell during re-selection.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

5-633
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.3.10 PS MIN RSCP of UTRAN reselecting cell_0/PS MIN RSCP of UTRAN reselecting
cell_1 (FDD_RSCPminPS_0/FDD_RSCPminPS_1)
PS MIN RSCP of UTRAN reselecting cell_0/PS MIN RSCP of UTRAN
Full Name

reselecting cell_1

Abbreviation

FDD_RSCPminPS_0/FDD_RSCPminPS_1

3GPP Name

FDD_RSCPmin

3GPP Reference

3GPP TS 45.008 V6.19.0


(PBCCH parameter) RSCP minimum value of UTRAN re-selection cell
indicates the minimum threshold for the re-selection to UTRAN FDD.
The parameterr is broadcast to an MS through packet system messages
PSI3quater. A one-dimensional array is used to indicate packet idle
state and packet transmission state parameters. When a UE is handed
over to a 3G adjacent cell, the following re-selection standards should
be met for longer than 5 seconds.
CPICH Ec/No > = FDD_ Qmin FDD_Qmin_Offset
CPICH RSCP > RLA_P(s+n) + _FDD_GPRS_Qoffset
CPICH RSCP > = FDD_RSCP_Threshold
The parameter FDD_GPRS_Qoffset, FDD_Qmin and FDD_Qmin_Offset
are broadcast to an MS through packet system messages PSI3quater.
RLA_P(s+n) is the average signal intensity of a serving cell and n GSM
adjacent cells with the strongest signal intensity.
FDD_RSCP_Threshold = FDD_RSCPmin min((P_MAX 21 dBm), 3
dB) If FDD_RSCPmin is broadcast in the system messages in a serving
cell; otherwise

Description

FDD_RSCP_Threshold = Qrxlevmin + Pcompensation + 10 dB

5-634
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

0 = -114 dBm, 1 = -112 dBm, 2 = -110 dBm, 3 = -108 dBm, 4 = -106


dBm, 5 = -104 dBm, 6 = -102 dBm, 7 = -100 dBm, 8 = -98 dBm, 9 = -96
dBm, 10 = -94 dBm, 11 = -92 dBm, 12 = -90 dBm, 13 = -88 dBm, 14 =
-86 dBm, 15 = -84 dBm. Note: The parameter in the formula are all
GPRS parameters.
Managed Object

Cell
The value range is 0..15
0 = -114 dBm
1 = -112 dBm
2 = -110 dBm
3 = -108 dBm
...
14 = -86 dBm

Value Range and Step

15 = -84 dBm

Unit

None

Default Value

Default Value

Refer to the parameter CS. The signal strength with -102 dBm RSCP is

Configuration Reason

strong enough to retain good radio communication under FDD.

Configuration Rule and

This parameter determines the minimum level for 3G FDD cell. It is

Adjustment Suggestion

harder to access the cells if the parameter is set higher. .

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-635
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.6.3.11 Measurement report threshold of Ec/No or RSCP_0/Measurement report


threshold of Ec/No or RSCP_1 (FDDRprtTho2PS_0/FDDRprtTho2PS_1)
Measurement report threshold of Ec/No or RSCP_0/Measurement report
Full Name

threshold of Ec/No or RSCP_1

Abbreviation

FDDRprtTho2PS_0/FDDRprtTho2PS_1

3GPP Name

FDD_REPORTING_THRESHOLD_2

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the report threshold of the CPICH parameter that
does not report measurement results according to FDD_REP_QUANT
(Ec/No or RSCP). The threshold is broadcast to MS through SI2quater
on BCCH, or through PACKET MEASUREMENT ORDER or PACKET
CELL CHANGE ORDER messages on PACCH. A one-dimensional array
is used to indicate packet idle state and packet transmission state parameters. If RXLEV mapped from CPICH Ec/No or RSCP is RXLEV exceeds
the threshold, a measurement report is generated. The measurement

Description

values are not included in the report. Default value = 0 (disabled)

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

Default Value
Configuration Reason

Recommended value in protocol.

Configuration Rule and


Adjustment Suggestion

The parameter should be set with a recommended value in protocol.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

Parameter Modifying
Version

None
5-636

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.6.3.12 PS class of reported quantities of UTRAN adjacent cells (FDDRepQntPS)


Full Name

PS class of reported quantities of UTRAN adjacent cells

Abbreviation

FDDRepQntPS

3GPP Name

FDD_REP_QUANT

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the type of measurement report. The parameter
information is passed to MS through PACKET MEASUREMENT ORDER
or PACKET CELL CHANGE ORDER messages. 0: RSCP, UE receiving
power of CPICH scramble of UTRAN cell, the unit is dBm;
1: Ec/No, ratio of the receiving power to thermal noise for CPICH

Description

scramble of UTRAN cell, the unit is dB.

Managed Object

Cell

Value Range and Step

(0, 1)

Unit

None

Default Value

Default Value

Refer to the configuration of CS parameter FDDRepQntCS. The default

Configuration Reason

value of FDDRepQntCS is 1.

Configuration Rule and

If a UE is expected to report with RSCP, the parameter should be set 0;

Adjustment Suggestion

if a UE is expected to report with Ec/Io, the parameter should be set 1.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

Parameter Modifying
Version

None

5-637
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.6.3.13 PS max number of UTRAN/FDD adjacent cells in measurement report


(FDDMulRatRrptPS)
Full Name

PS max number of UTRAN/FDD adjacent cells in measurement report

Abbreviation

FDDMulRatRrptPS

3GPP Name

FDD_MULTIRAT_REPORTING

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the maximum number of UTRAN/TDD adjacent
cells included in measurement report or strongest cell list. The parameter
information is broadcast to MS through PSI3quater, or broadcast to MS
through PACKET MEASUREMENT ORDER or PACKET CELL CHANGE
ORDER messages on PACCH. If UTRAN/FDD adjacent cells are not full,
the vacancies are for GSM adjacent cells. (If TDD technology is available,

Description

the vacancies are reserved for TDD cells)

Managed Object

Cell

Value Range and Step

(0, 1, 2, 3)

Unit

None

Default Value

Default Value
Configuration Reason

Refer to the CS parameter FDDMulRatrrptCS.

Configuration Rule and

The parameter should be set higher if a UE is expected to stay in FDD

Adjustment Suggestion

network.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

5-638
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.3.14 PS multi-band report indication (MulBndRprtPS)


Full Name

PS multi-band report indication

Abbreviation

MulBndRprtPS

3GPP Name

MULTIBAND_REPORTING

3GPP Reference

3GPP TS 45.008 V6.19.0


The multiband indication parameter means the number of cells reported
by each band in the quality report or in the list that includes the six
cells with the strongest signal intensity. The parameter information is
broadcast to MS through PSI3 or PSI5, or broadcast to MS through
PACKET MEASUREMENT ORDER or PACKET CELL CHANGE
ORDER messages on PACCH. This parameter is to control the number
of reports of different adjacent cells except the serving cell with other
frequency band. 0: MS reports the survey results of six known and
allowed adjacent cells with the strongest NCC according to the signal
intensity, regardless of which frequency band adjacent cells are in;
1: MS reports the survey result of one adjacent cell with the strongest
signals in the frequency bands (excluding that of local cell) in adjacent
cell table. In the remained locations, MS reports the adjacent cells
in the frequency band of local cell. If there are still more remained
locations, MS reports the second strongest adjacent cell, regardless
of their frequency bands;
2: MS reports the measurement result of two adjacent cells with
strongest signal in the frequency bands in adjacent cell list (excluding
frequency band of serving cell). 2In the remained locations, MS reports
the adjacent cells in the frequency band of local cell. If there are still
more remained locations, MS reports the second strongest adjacent cell,
regardless of their frequency bands;
3: MS reports the measurement result of three adjacent cells with
strongest signal in the frequency bands in adjacent cell list (excluding
frequency band of serving cell). In the remaining locations, MS reports
the adjacent cells in the frequency band of local cell. If there are still
more locations remaining, MS reports the second strongest adjacent

Description

cell, regardless of their frequency bands.

Managed Object

Cell

Value Range and Step

(0, 1, 2, 3)

5-639
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

Default Value
Configuration Reason

The report is based on signal intensity. All the bands are treated same.
When a certain number of adjacent cells are expected to be reported, the
parameter should be set with a value other than 0. In a dual-frequency
environment, the 900 M cells can be set to report as many 1800 M
cells as possible to make the handover conducted in 1800 M frequency

Configuration Rule and


Adjustment Suggestion

(set 3), and the 1800 M cells can be set to report as few 900 M cells
as possible (set 1).
In a dual-frequency environment, the parameter can be set 0 to limit the
traffic bearing, that is, the cell report should base on the signal strength.
This configuration is good to balance the traffic and lower and reduce
congestion. However, the success ratio of handover, call drop ratio and
coverage ratio might be affected.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.3.15 TDD multi report PS (TDDMulRatRrptPS)


Full Name

TDD multi report PS

Abbreviation

TDDMulRatRrptPS

3GPP Name

TDD_MULTIRAT_REPORTING

3GPP Reference

3GPP TS 45.008 V6.19.0

5-640
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter indicates the maximum number of UTRAN/TDD adjacent


cells included in measurement report or strongest cell list. The parameter information is passed to an MS through PACKET MEASUREMENT
ORDER messages or PACKET CELL CHANGE ORDER messages on
PACCH. If UTRAN/FDD adjacent cells are not full, the vacancies are reserved for GSM adjacent cells. (If TDD technology is available, the vaDescription

cancies are reserved for TDD cells)

Managed Object

Cell

Value Range and Step

(0, 1, 2, 3)

Unit

None

Default Value

Default Value
Configuration Reason

Refer to the CS parameter TDDMulRatrrptCS.

Configuration Rule and

The parameter should be set higher if a UE is expected to stay in TDD

Adjustment Suggestion

network.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 1

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.4 GPRS Parameters 2


5.6.4.1 PS UE report invalid cell level allowed (InvldBSICRprtPS)
Full Name

PS UE report invalid cell level allowed

5-641
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

InvldBSICRprtPS

3GPP Name

INVALID_BSIC_REPORTING

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates whether the GSM cells with invalid BSIC and
allowed by NCC are reported. NCC in BSIC of some GSM cells are
allowed, but BCC is invalid (that is, the radio system does not have
adjacent cells corresponding to BCC). This parameter indicates whether
the system allows UE to report field intensity of such cells (NCC is
allowed but BCC is invalid). The parameter information is passed to an
MS through PACKET MEASUREMENT ORDER messages or PACKET
CELL CHANGE ORDER messages on PACCH. YES: Allow UE to report
the field intensity of "NCC permitted but BCC invalid" cells; "
NO: Do not Allow UE to report the field intensity of "NCC permitted but

Description

BCC invalid" cells;

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

BCC does not know the adjacent cell, which is not configured in BSC.

Configuration Reason

The cell cannot be the target during handover process.

Configuration Rule and


Adjustment Suggestion

It is recommended to set as "No".

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-642
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.6.4.2 PS UE search UTRAN adjacent cell in basic decoding frame indication


(SearchPrioPS3G)
Full Name

PS UE search UTRAN adjacent cell in basic decoding frame indication

Abbreviation

SearchPrioPS3G

3GPP Name

3G_SEARCH_PRIO

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates whether UE searches UTRAN adjacent cells
when BSIC decoding is required. If allowed, UE can use at most 25
frames for search in 13 seconds. The parameter information is passed
to an MS through PACKET MEASUREMENT ORDER messages or

Description

PACKET CELL CHANGE ORDER messages on PACCH. 0 = no, 1 = yes

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

Refer to the CS parameter.

Configuration Rule and

If a user is expected to stay in 3G network, this parameter should be

Adjustment Suggestion

set as "Yes".

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-643
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.6.4.3 Reselect priority control of 2G/3G (ServiceCC)


Full Name

Reselect priority control of 2G/3G

Abbreviation

ServiceCC

3GPP Name

None

3GPP Reference

None
Choose 2G/3G re-select priority control.
0 .. 5, 0: 3G re-selection preferred; 1: 3G re-selection not preferred; 2:
3G re-selection not allowed; 3: Based on the information from SGSN,
3G re-selection preferred by default; 4: Based on the information from
SGSN, 3G re-selection not preferred by default; 5: Based on the
information from SGSN, 3G re-selection not allowed.
This parameter takes effect when NCCC has been started. That is,

Description

NC2Support should be 1, and the NMO should be 1 (NC2).

Managed Object

Cell
3G re-selection preferred;
3G re-selection not preferred;
3G re-selection not allowed;
Based on the information from SGSN, 3G re-selection preferred by
default;
Based on the information from SGSN, 3G re-selection not preferred
by default;
Based on the information from SGSN, 3G re-selection not allowed by

Value Range and Step

default;

Unit

None

Default Value

3G re-selection preferred;

Default Value
Configuration Reason

Usually PS services for 3G are better than those for 2G.

Configuration Rule and

Adjust according to 2/3G inter-working strategy (3G preferred, or 2G

Adjustment Suggestion

preferred).

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-644
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.4.4 GSM 850 Offset (RprtOffsetPS850)


Full Name

GSM 850 Offset

Abbreviation

RprtOffsetPS850

3GPP Name

850_REPORTING_OFFSET

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the offset on the reported value in GSM 850
M frequency when the cell sorting takes priority. The parameter information is passed to an MS through PACKET MEASUREMENT ORDER
messages or PACKET CELL CHANGE ORDER messages on PACCH.
During the report of GSM 850 M adjacent cells, if signal level in two cells
are higher than or equal to RprtThoCS850, and RepPrioCS values are the
same, the cell with bigger sum of signal level value and RprtOffsetCS850

Description

value is first reported.

Managed Object

Cell

Value Range and Step

(0, 1, 2, 3, 4, 5, 6, 7) 0..7, corresponding to 0..42 dB, 6 dB for each level

Unit

None

Default Value

Default Value
Configuration Reason

The recommended value in protocol. No offset.

Configuration Rule and

It is easier to be chosen for measurement report hand-in if the value is

Adjustment Suggestion

bigger.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

5-645
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.4.5 GSM 850 Threshold (RprtThoPS850)


Full Name

GSM 850 Threshold

Abbreviation

RprtThoPS850

3GPP Name

850_REPORTING_THRESHOLD

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter means the measurement report threshold of GSM 850 M
band. The parameter information is passed to an MS through PACKET
MEASUREMENT ORDER messages or PACKET CELL CHANGE ORDER messages on PACCH. The GSM 850 M adjacent cells can be reported only when signal level in the cell is higher than or equal to RprtThoPS850 (dimensionless, corresponding to RXLEV portion in measurement report, different mapping relationship for different RXLEV). Whether
it can be reported in certain period depends on signal level, RepPrioPS,

Description

MulBndRprtPS and RprtOffsetPS850.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7
0: always;
1..6: corresponding to 6..36, each level 6;

Value Range and Step

7: never

Unit

None

Default Value

Default Value

If the parameter uses the recommended value in protocol, there is no

Configuration Reason

threshold.

Configuration Rule and

A cell is easier to be chosen for measurement report if the value is

Adjustment Suggestion

smaller and vice versa.

Change Mode

Offline

Related features

None

5-646
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.4.6 GSM 900 Offset (RprtOffsetPS900)


Full Name

GSM 900 Offset

Abbreviation

RprtOffsetPS900

3GPP Name

900_REPORTING_OFFSET

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the offset on the reported value in GSM 900
M frequency when the cell sorting takes priority. The parameter information is passed to an MS through PACKET MEASUREMENT ORDER
messages or PACKET CELL CHANGE ORDER messages on PACCH.
During the report of GSM 900 M adjacent cells, if signal level in two cells
are higher than or equal to RprtThoPS900, and RepPrioPS values are the
same, the cell with bigger sum of signal level value and RprtOffsetPS900

Description

value is first reported.

Managed Object

Cell

Value Range and Step

(0, 1, 2, 3, 4, 5, 6, 7) 0..7, corresponding to 0..42 dB, 6 dB for each level

Unit

None

Default Value

Default Value
Configuration Reason

The recommended value in protocol. No offset.

Configuration Rule and

It is easier to be chosen for measurement report hand-in if the value is

Adjustment Suggestion

bigger.

5-647
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.4.7 GSM 900 Threshold (RprtThoPS900)


Full Name

GSM 900 Threshold

Abbreviation

RprtThoPS900

3GPP Name

900_REPORTING_THRESHOLD

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter means the measurement report threshold of GSM 900 M
band. The parameter information is passed to an MS through PACKET
MEASUREMENT ORDER messages or PACKET CELL CHANGE ORDER messages on PACCH. The GSM 900 M adjacent cells can be reported only when signal level in the cell is higher than or equal to RprtThoPS900 (dimensionless, corresponding to RXLEV portion in measurement report, different mapping relationship for different RXLEV). Whether
it can be reported in certain period depends on signal level, RepPrioPS,

Description

MulBndRprtPS and RprtOffsetPS900.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7
0: always;
1..6: corresponding to 6..36, each level 6;

Value Range and Step

7: never

Unit

None

5-648
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

Default Value

If the parameter uses the recommended value in protocol, there is no

Configuration Reason

threshold.

Configuration Rule and

A cell is easier to be chosen for measurement report if the value is

Adjustment Suggestion

smaller and vice versa.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.4.8 GSM 1800 Offset (RprtOffsetPS1800)


Full Name

GSM 1800 Offset

Abbreviation

RprtOffsetPS1800

3GPP Name

1800_REPORTING_OFFSET

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the offset on the reported value in GSM 1800
M frequency when the cell sorting takes priority. The parameter information is passed to an MS through PACKET MEASUREMENT ORDER
messages or PACKET CELL CHANGE ORDER messages on PACCH.
During the report of GSM 1800 M adjacent cells, if signal level in two
cells are higher than or equal to RprtThoPS1800, and RepPrioPS values
are the same, the cell with bigger sum of signal level value and RprtOff-

Description

setPS1800 value is first reported.

Managed Object

Cell

5-649
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Value Range and Step

(0, 1, 2, 3, 4, 5, 6, 7) 0..7, corresponding to 0..42 dB, 6 dB for each level

Unit

None

Default Value

Default Value
Configuration Reason

The recommended value in protocol. No offset.

Configuration Rule and

It is easier to be chosen for measurement report hand-in if the value is

Adjustment Suggestion

bigger.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.4.9 GSM 1800 Threshold (RprtThoPS1800)


Full Name

GSM 1800 Threshold

Abbreviation

RprtThoPS1800

3GPP Name

1800_REPORTING_THRESHOLD

3GPP Reference

3GPP TS 45.008 V6.19.0

5-650
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter means the measurement report threshold of GSM 1800


M band. The parameter information is passed to an MS through PACKET
MEASUREMENT ORDER messages or PACKET CELL CHANGE
ORDER messages on PACCH. The GSM 1800 M adjacent cells can
be reported only when signal level in the cell is higher than or equal
to RprtThoPS1800 (dimensionless, corresponding to RXLEV portion in
measurement report, different mapping relationship for different RXLEV).
Whether it can be reported in certain period depends on signal level,
Description

RepPrioPS, MulBndRprtPS and RprtOffsetPS1800.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7
0: always;
1..6: corresponding to 6..36, each level 6;

Value Range and Step

7: never

Unit

None

Default Value

Default Value

If the parameter adopts the recommended value in protocol, there is

Configuration Reason

no threshold.

Configuration Rule and

It is easier to be chosen for measurement report hand-in if the value

Adjustment Suggestion

is smaller, and vice versa.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-651
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.6.4.10 GSM 1900 Offset (RprtOffsetPS1900)


Full Name

GSM 1900 Offset

Abbreviation

RprtOffsetPS1900

3GPP Name

1900_REPORTING_OFFSET

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the offset on the reported value in GSM 1900
M frequency when the cell sorting takes priority. The parameter information is passed to an MS through PACKET MEASUREMENT ORDER
messages or PACKET CELL CHANGE ORDER messages on PACCH.
During the report of GSM 1900 M adjacent cells, if signal level in two
cells are higher than or equal to RprtThoPS1900, and RepPrioPS values
are the same, the cell with bigger sum of signal level value and RprtOff-

Description

setPS1900 value is first reported.

Managed Object

Cell

Value Range and Step

(0, 1, 2, 3, 4, 5, 6, 7) 0..7, corresponding to 0..42 dB, 6 dB for each level

Unit

None

Default Value

Default Value
Configuration Reason

The recommended value in protocol. No offset.

Configuration Rule and

It is easier to be chosen for measurement report hand-in if the value is

Adjustment Suggestion

bigger.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-652
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.6.4.11 GSM 1900 Threshold (RprtThoPS1900)


Full Name

GSM 1900 Threshold

Abbreviation

RprtThoPS1900

3GPP Name

1900_REPORTING_THRESHOLD

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter means the measurement report threshold of GSM 1900
M band. The parameter information is passed to an MS through PACKET
MEASUREMENT ORDER messages or PACKET CELL CHANGE ORDER messages on PACCH. The GSM 1900 M adjacent cells can be reported only when signal level in the cell is higher than or equal to RprtThoPS1900 (dimensionless, corresponding to RXLEV portion in measurement report, different mapping relationship for different RXLEV). As
to whether it can be reported in certain period, it also depends on signal

Description

level, RepPrioPS, MulBndRprtPS and RprtOffsetPS1900.

Managed Object

Cell
0, 1, 2, 3, 4, 5, 6, 7
0: always;
1..6: corresponding to 6..36, each level 6;

Value Range and Step

7: never

Unit

None

Default Value

Default Value

If the parameter uses the recommended value in protocol, there is no

Configuration Reason

threshold.

Configuration Rule and

A cell is easier to be chosen for measurement report if the value is

Adjustment Suggestion

smaller and vice versa.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 2

5-653
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.4.12 UTRAN/FDD Offset (FDDRprtOffsetPS)


Full Name

UTRAN/FDD Offset

Abbreviation

FDDRprtOffsetPS

3GPP Name

FDD_REPORTING_OFFSET

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the offset on the reported value in UTRAN FDD
frequency when the cell sorting takes priority. The parameter information
is passed to an MS through PACKET MEASUREMENT ORDER messages or PACKET CELL CHANGE ORDER messages on PACCH. The
parameter information is passed to an MS through PACKET MEASUREMENT ORDER messages or PACKET CELL CHANGE ORDER messages on PACCH. During the report of UTRAN/FDD adjacent cells, if signal level in two cells are higher than or equal to FDDRprtThoPS, and
RepPrioPS values are the same, the cell with bigger sum of signal level

Description

value and FDDRprtOffsetPS value is first reported.

Managed Object

Cell

Value Range and Step

(0, 1, 2, 3, 4, 5, 6, 7) 0..7, corresponding to 0..42 dB, 6 dB for each level

Unit

None

Default Value

Default Value
Configuration Reason

The recommended value in protocol. No offset.

Configuration Rule and

It is easier to be chosen for measurement report hand-in if the value is

Adjustment Suggestion

bigger.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

5-654
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.4.13 UTRAN/FDD Threshold (FDDRprtThoPS)


Full Name

UTRAN/FDD Threshold

Abbreviation

FDDRprtThoPS

3GPP Name

FDD_REPORTING_THRESHOLD

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter means the measurement report threshold of UTRAN FDD.
The parameter information is passed to an MS through PACKET MEASUREMENT ORDER messages or PACKET CELL CHANGE ORDER
messages on PACCH. The parameter information is passed to an MS
through PACKET MEASUREMENT ORDER messages or PACKET CELL
CHANGE ORDER messages on PACCH. When reporting to UTRAN/FDD
adjacent cells, only when signal level in the cell is higher than or equal
to FDDRprtThoCS (dimensionless, corresponding to RXLEV portion in
measurement report, different mapping relationship for different RXLEV),
it can be reported. As to whether it can be reported in certain period, it
also depends on signal level, RepPrioCS, FDDMulRatRrptCS and FDDR-

Description

prtOffsetCS.

Managed Object

Cell
(0, 1, 2, 3, 4, 5, 6, 7) 0: always;
1..6: corresponding to 6..36, each level 6;

Value Range and Step

7: never

Unit

None

Default Value

Default Value

If the parameter adopts the recommended value in protocol, there is

Configuration Reason

no threshold.

Configuration Rule and

It is easier to be chosen for measurement report hand-in if the value

Adjustment Suggestion

is smaller, and vice versa.

Change Mode

Offline

5-655
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS parameters 2
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.4.14 UTRAN/TDD Offset (TDDRprtOffsetPS)


Full Name

UTRAN/TDD Offset

Abbreviation

TDDRprtOffsetPS

3GPP Name

TDD_REPORTING_OFFSET

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the offset on the reported value in UTRAN
FDD frequency when the cell sorting takes priority.

The parameter

information is passed to an MS through PACKET MEASUREMENT


ORDER messages or PACKET CELL CHANGE ORDER messages on
PACCH. The parameter information is passed to an MS through PACKET
MEASUREMENT ORDER messages or PACKET CELL CHANGE ORDER messages on PACCH. The parameter information is passed to an
MS through PACKET MEASUREMENT ORDER messages or PACKET
CELL CHANGE ORDER messages on PACCH. During the report of
UTRAN/FDD adjacent cells, if signal level in two cells are higher than or
equal to TDDRprtThoPS, and RepPrioPS values are the same, the cell
with bigger sum of signal level value and TDDRprtOffsetPS value is first
Description

reported.

Managed Object

Cell

Value Range and Step

(0, 1, 2, 3, 4, 5, 6, 7) 0..7, corresponding to 0..42 dB, 6 dB for each level

Unit

None

5-656
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

Default Value
Configuration Reason

The recommended value in protocol. No offset.

Configuration Rule and

It is easier to be chosen for measurement report hand-in if the value is

Adjustment Suggestion

bigger.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.4.15 UTRAN/TDD Threshold (TDDRprtThoPS)


Full Name

UTRAN/TDD Threshold

Abbreviation

TDDRprtThoPS

3GPP Name

TDD_REPORTING_THRESHOLD

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter means the measurement report threshold of UTRAN TDD.
The parameter information is passed to an MS through PACKET MEASUREMENT ORDER messages or PACKET CELL CHANGE ORDER
messages on PACCH. When reporting to UTRAN/TDD adjacent cells,
only when signal level in the cell is higher than or equal to TDDRprtThoPS
(dimensionless, corresponding to RXLEV portion in measurement report,
different mapping relationship for different RXLEV), it can be reported.
Whether it can be reported in certain period depends on signal level, Rep-

Description

PrioPS, TDDMulRatRrptPS and TDDRprtOffsetPS.

Managed Object

Cell
5-657

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0, 1, 2, 3, 4, 5, 6, 7
0: always;
1..6: corresponding to 6..36, each level 6;
Value Range and Step

7: never

Unit

None

Default Value

Default Value

If the parameter uses the recommended value in protocol, there is no

Configuration Reason

threshold.

Configuration Rule and

A cell is easier to be chosen for measurement report if the value is

Adjustment Suggestion

smaller and vice versa.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 2

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.6.4.16 Signal strength and load and capacity priority (StrenLoadCapaPri)


Full Name

Signal strength and load and capacity priority

Abbreviation

StrenLoadCapaPri

3GPP Name

None

3GPP Reference

None

5-658
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter determines the reselection judgment principle. 0: In the


process of reselection judgment, the signal strength is preferred.
1: In the process of reselection judgment, the load is preferred.
2: In the process of reselection judgment, the remaining capacity is
Description

preferred.

Managed Object

Cell

Value Range and Step

0..2

Unit

None

Default Value

Default Value

Unless otherwise specified, the signal strength is used as the reselection

Configuration Reason

judgment condition.

Configuration Rule and


Adjustment Suggestion

It is required to configure this parameter according operator


requirements. For balance based on load, select 1. For balance based
on capacity, select 2..

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Control->GPRS parameters 2
Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.6.4.17 Signal strength threshold (StrenThr)


Full Name

Signal strength threshold

Abbreviation

StrenThr

3GPP Name

None

3GPP Reference

None

5-659
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines the threshold of minimum access strength


for the 3G cell that is reselected to the 3G adjacent cell. If the strength
is higher than this threshold, the value is acceptable. The relationship
between the field and the strength is as follows:
0 -105dBm
1 -102dBm
2 -99dBm
3 -96dBm
4 -93dBm
5 -90dBm
6 -87dBm
7 -84dBm
8 -81dBm
9 -78dBm
10 -75dBm
11 -72dBm
12 -69dBm
13 -66dBm
14 -63dBm
Description

15 -60dBm

Managed Object

Cell

Value Range and Step

0..15

Unit

dBm

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

In the case of normal UE access, use the lowest signal strength.


When there are high requirements on the signal strength in the
reselected target 3G cell of the UE, it is recommended that this
parameter be configured relatively large. Otherwise, lower this value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-660
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 2

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.6.4.18 Load threshold (LoadThr)


Full Name

Load threshold

Abbreviation

LoadThr

3GPP Name

None

3GPP Reference

None
This parameter determines the threshold of maximum access load for the
3G cell that is reselected to the 3G adjacent cell. If the load is lower than

Description

this threshold, the value is acceptable.

Managed Object

Cell

Value Range and Step

0..100

Unit

Default Value

60

Default Value

According to the load balancing principle, the cell load cannot be

Configuration Reason

excessively high after the UE is reselected to a 3G cell.


It is required to configure the expected load that can be acceptable by

Configuration Rule and


Adjustment Suggestion

the target 3G cell. If the 2G PS service is busy, this parameter can be


configured relatively high when the 3G service is not congested. This
facilitates the UE to be reselected to the 3G cell. On the contrary, lower
the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-661
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 2

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.6.4.19 Available capacity threshold (CapaThr)


Full Name

Available capacity threshold

Abbreviation

CapaThr

3GPP Name

None

3GPP Reference

None
This parameter determines the threshold of remaining access capacity
for the 3G cell that is reselected to the 3G adjacent cell. If the remaining

Description

access capacity is higher than this threshold, the value is acceptable.

Managed Object

Cell

Value Range and Step

1..100

Unit

None

Default Value

40

Default Value
Configuration Reason

According to the load balancing principle, number of subscribers


accessed by a cell cannot be excessively low after the UE is reselected
to the 3G cell.
It is required to configure the expected remaining access capacity that

Configuration Rule and


Adjustment Suggestion

can be acceptable by the target 3G cell. If the 2G PS service is busy,


this parameter can be configured relatively low when the 3G service is
not congested. This facilitates the UE to be reselected to the 3G cell. On
the contrary, increase the value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
5-662

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Cell


Control->GPRS parameters 2

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

5.7 Adjacent Cell Parameters


5.7.1 Adjacent Interference Cell Parameters
5.7.1.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None

Description

This parameter means the site ID. It cannot be modified.


Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
5-663

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Interference
OMC Access Path
Parameter

Modifying

Version
Parameter

Cell

None
Modifying

Detail

None

5.7.1.2 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell
1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None
5-664

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Interference

OMC Access Path


Parameter

Modifying

Version
Parameter

Cell

None
Modifying

Detail

None

5.7.1.3 Interference cell ID (IntfObjectId)


Full Name

Interference cell ID

Abbreviation

IntfObjectId

3GPP Name

None

3GPP Reference

None
This parameter indicates the identification numbers for adjacent interfer-

Description

ence cells.

Managed Object

Cell

Value Range and Step

1..6

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

5-665
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent


Interference Cell

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.1.4 Related Cell DN (RelationDN)


Full Name

Related Cell DN

Abbreviation

RelationDN

3GPP Name

None

3GPP Reference

None
This parameter indicates the DN of the external cell in the current BSS
system: EcId, or the DN for the related equipment in the current BSS

Description

system: BscId-SiteId-BtsId

Managed Object

Cell

Value Range and Step

None

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

5-666
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent


Interference Cell

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2 Adjacent Cell Handover and Reselection Parameters


5.7.2.1 Basic Property
5.7.2.1.1 User Label
Full Name

User Label

Abbreviation

UserLabel

3GPP Name

None

3GPP Reference

None

Description

This parameter is the cell handover reselection name for users to identify.

Managed Object

Cell

Value Range and


Step

Character string with the maximum length of 40

Unit

None

Default Value

None

Default Value
Configuration
Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None
5-667

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell Handover

OMC Access Path

and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.2 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None

Description

This parameter means the site ID. It cannot be modified.


Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell Han-

OMC Access Path

dover and Reselection->Basic Property

5-668
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter

Modifying

Version
Parameter

None
Modifying

Detail

None

5.7.2.1.3 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell
1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

5-669
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell Han-

OMC Access Path


Parameter

Modifying

Version
Parameter

dover and Reselection->Basic Property

None
Modifying

Detail

None

5.7.2.1.4 Adjacent cell handover and reselection ID (HoResObjectId)


Full Name

Adjacent cell handover and reselection ID

Abbreviation

HoResObjectId

3GPP Name

None

3GPP Reference

None
This parameter is a unique identification of a reselection object during

Description

adjacent cell handover.

Managed Object

Cell

Value Range and Step

1..64

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline

Related features

ZGO-02-03-011 Service Indicator in Handover and Reselection

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-670
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.5 Priority of handover (Hopriority)


Full Name

Priority of handover

Abbreviation

Hopriority

3GPP Name

None

3GPP Reference

None
According to GSM specifications, cell priority should be considered in sequencing candidate cells. Therefore, there are three decisive factors to
sequence candidate cells: priority, traffic, and radio communication environment. Priority and traffic have the most impact on cell sequencing.
If they lead to the same result, sequence cells by radio conditions. The

Description

priority of a cell is higher if this value is set higher.

Managed Object

Cell
0..7

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

In most cases, this parameter is set to 3, and the cell priority are the

Configuration Reason

same.

Configuration Rule and

In most cases, this parameter is set to 3, and the cell priority are the

Adjustment Suggestion

same.

Change Mode

Offline

Related features

ZGO-02-02-002 Dynamic Handover Priority Algorithm

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-671
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.6 MAX power level of MS (MsTxPwrMax)


Full Name

MAX power level of MS

Abbreviation

MsTxPwrMax

3GPP Name

MS_TXPWR_MAX

3GPP Reference

3GPP TS 45.008 V5.22.0


During the communication between MS and BTS, the transmission
power of MS is controlled by the network. The network sets the power
for MS through the power command and the command is transmitted on
SACCH (SACCH has 2 header bytes, one is the power control byte and
the other is the TA byte).
An MS sets the specified output transmission power according to the
power control header extracted from the SACCH. An MS uses the closest
possible output power if it cannot output the specified power. MS max

Description

power level is also a parameter used by BSC to calculate PBGT value.

Managed Object

Cell
0..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The maximum power for most MSs

Configuration Rule and


Adjustment Suggestion

For 900 M, set the parameter to 5; for 1800 M, set it to 0.

Change Mode

Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

5-672
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.7 MIN power level for handover access (RxLevMin)


Full Name

MIN power level for handover access

Abbreviation

RxLevMin

3GPP Name

RXLEV_ACCESS_MIN

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter defines the minimum receiving strength level (on BCCH)
required for MS to handover to this cell. It is one of the parameters to
decide preferred cells during handover control. MS in the serving cell
constantly monitors the signal intensity on BCCH of adjacent cells.
Adjacent cells with the receiving intensity level higher than the minimum
value defined by this parameter are candidates for handover.
It is advised to set this parameter to approximate MS receiving sensitivity.
For some cells with traffic overload, increase the minimum access level
to decrease C1 and C2 value of the cell, and the cell coverage range
decreases at the same time. Setting the minimum access level too large
will cause crossover area of cells to become "dead area. The level
should not exceed -90 dBm for cell traffic balancing conditions. At the
preliminary running stage of the network, this parameter can be usually
set as 10 (that is, -101 dBm .. -100 dBm) or lower, which is higher than
the MS receiving sensitivity -102 dBm. However, when the network
capacity is expanded or the radio coverage in a cell is not a problem,

Description

this parameter of the cell can be increased by 2.

Managed Object

Cell

5-673
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0 .. 63
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
2: -109 dBm .. -108 dBm;
...
62: -49 dBm .. -48 dBm;
63: > -48 dBm
Value Range and Step

Step: 1

Unit

None

Default Value

15

Default Value
Configuration Reason

This parameter is set based on experience.


The value of this parameter must be higher than the minimum access

Configuration Rule and


Adjustment Suggestion

level of the corresponding adjacent cell, and the value should also be
higher or equal to the dowmlink level handover threshold, otherwise
frequent handover or reselection will happen.

Change Mode

Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.8 MIN threshold of signal level for handover on PBGT (HoMarginPbgt)


Full Name

MIN threshold of signal level for handover on PBGT

Abbreviation

HoMarginPbgt

3GPP Name

None

5-674
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Reference

3GPP TS 45.008 V5.22.0


According to GSM specifications, handover decisions will be made after
a series of average values have been obtained. The PBGT value of
an adjacent cell is also one of the causes for handover. The decision
process is as follows: If the PBGT value of an adjacent cell is higher
than the relevant threshold of this cell, handover shall be performed to
find a more suitable cell.
This parameter defines the threshold used to determine PBGT handover

Description

from an adjacent cell to local cell.

Managed Object

Cell
0..100
0: -24 dB;
1: -23 dB;
...
100: 76 dB

Value Range and Step

Step: 1

Unit

None

Default Value

30

Default Value

In most cases, if the minimum PGBT handover threshold is set to 30, an

Configuration Reason

MS can be handed over to an adjacent cell with better level.

Configuration Rule and

It becomes easier to trigger a PBGT handover if the threshold value

Adjustment Suggestion

is set lower.

Change Mode

Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None
5-675

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.7.2.1.9 MIN threshold of signal level for handover on power level (HoMarginRxLev)
Full Name

MIN threshold of signal level for handover on power level

Abbreviation

HoMarginRxLev

3GPP Name

None

3GPP Reference

None
According to GSM specifications, handover decisions will be made after a
series of average values have been obtained. In handover caused by the
level, adjacent cells shall be screened and sequenced. The value should
be higher or equal to the threshold. This parameter defines the signal

Description

strength threshold to determine handover from adjacent cell to local cell.

Managed Object

Cell
0 .. 100
0: -24 dB;
1: -23 dB;
...
100: 76 dB

Value Range and Step

Step: 1

Unit

None

Default Value

30

Default Value

The value of a target cell should be set higher to ensure that a handover

Configuration Reason

is conducted correctly.

Configuration Rule and


Adjustment Suggestion

A handover based on signal strength is a kind of rescue handover. The


threshold should be set lower (lower than PBGT threshold) to ensure a
handover can be conducted in time.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None
5-676

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.7.2.1.10 MIN threshold of signal level for handover on quality (HoMarginRxQual)


Full Name

MIN threshold of signal level for handover on quality

Abbreviation

HoMarginRxQual

3GPP Name

None

3GPP Reference

None
According to GSM specifications, handover decisions will be made after a
series of average values have been obtained. In handover based on quality, adjacent cells shall be screened and sequenced. The value should be
higher or equal to the threshold. This parameter defines the signal quality

Description

threshold to determine handover from an adjacent cell to the local cell.

Managed Object

Cell
0 .. 100
0: -24 dB;
1: -23 dB;
...
100: 76 dB

Value Range and Step

Step: 1

Unit

None

Default Value

30

Default Value

The value of a target cell should be set higher to ensure that a handover

Configuration Reason

is conducted correctly.

Configuration Rule and


Adjustment Suggestion

A handover based on signal quality is a kind of rescue handover. The


threshold should be set lower (lower than the strength threshold) to
ensure a handover can be conducted in time.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-677
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.11 MAX level difference of force handover (MaxForceHoDiff)


Full Name

MAX level difference of force handover

Abbreviation

MaxForceHoDiff

3GPP Name

None

3GPP Reference

None
Force traffic transfer handover is performed only for one designated cell
and it is restricted by a tolerable level difference MaxLevDiff. This level
difference is lower than PBGT handover threshold in reverse direction,

Description

thus to avoid oscillating handover.

Managed Object

Cell
0..48
(-24 dB..24 dBm)

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The level difference between two cells should not be too big or too small.

Configuration Reason

9 is a recommended value.

Configuration Rule and


Adjustment Suggestion

The lower the level difference. the more likely the handover will happen.
The parameter cannot be set too low, otherwise frequent ping-pong
handovers will be caused.

Change Mode

Offline

Related features

ZGO-02-02-003 Directed-Shift Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-678
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.12 Handover force resource threshold (HoForceResThs)


Full Name

Handover force resource threshold

Abbreviation

HoForceResThs

3GPP Name

None

3GPP Reference

None
The force migration will not cause congestion in a cell, so a transfer
reserved resource threshold is set. When resource of object cell is lower
than the congestion threshold, forced handover can be implemented.
The formula to calculate the resource threshold is: 100 - currentTCH
load in a cell >= transfer reserved resource threshold
Current TCH load in a cell = total number of busy TCH *100 / (total
number of busy TCH + total number of idle TCH), the total number

Description

includes the dynamic ones and static ones.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

40

Default Value

The threshold should not be too high or too low. 40 is the recommended

Configuration Reason

value.

Configuration Rule and

The threshold cannot be set too high to avoid force transfer of

Adjustment Suggestion

overloaded traffic in a cell.

Change Mode

Offline

Related features

ZGO-02-02-003 Directed-Shift Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

0
5-679

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.13 Neighboring cell layer (NCellLayer)


Full Name

Neighboring cell layer

Abbreviation

NCellLayer

3GPP Name

None

3GPP Reference

None
This parameter provides the handover policies in multilayer network
technology and dual-frequency network technology. Multilayer radio
coverage can be formed in the same physical area.
The PBGT handover defined in the specifications at one layer is limited
to reduce the number of handovers during the call, thus improving the
system reliability and communication quality. The policy of handover
between a macro cell layer and a micro cell layer mainly depends on the
moving speed of MS. An MS at higher moving speed will try to stay at
the macro cell layer (upper layer of the micro cell layer), and an MS at
lower moving speed will try to enter the micro cell layer (lower layer
of the macro cell layer). Only in the case of non-PBGT handover and
emergency, will the undefined cell of the service area be considered
as a candidate cell.
Same layer of this cell: Adjacent cell and this cell are in the same layer
(PBGT handover possible); Upper layer of this cell: Adjacent cell is the
upper layer of this cell; Lower layer of this cell: Adjacent cell is the lower

Description

layer of this cell;

Managed Object

Cell
undefined
Same layer of this cell
upper layer of this cell

Value Range and Step

lower layer of the this cell

Unit

None

Default Value

The neighboring cell is at the same layer as this cell.

Default Value
Configuration Reason

Generally, the network is a single layer network.


5-680

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This layer, which belongs to the logic layer, has nothing to do with
the actual coverage and network frequency band. For example,
900M->900M can be set to the same layer, upper layer, or lower layer,
and 1800M->900M can also be set to the same layer, upper layer, or
lower layer.
Layer relationship brings an impact on the priority of target cell
Configuration Rule and
Adjustment Suggestion

selection and sequence (referring to Handover Algorithm Application


Guide). Usually, handover with layer relationship includes PBGT
handover, macro-micro handover, and traffic handover. Among which,
the macro-micro handover can be triggered only when adjacent cell
relationship (handover from upper layer to lower layer) is set.
As each Layer is able to share some traffic, it is suggested to flexibly
set layers for different adjacent cells to share traffic, so as to improve
congestion rate.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.14 CS adjacent cell report priority (RepPrioCS)


Full Name

CS adjacent cell report priority

Abbreviation

RepPrioCS

3GPP Name

REP_PRIORITY

3GPP Reference

3GPP TS 45.008 V5.22.0

5-681
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The adjacent cell reporting is performed according to the following


priorities:
Adjacent cells with same frequency band must have the following
features: BSIC of color code is valid; Its measured field intensity ranks
high among cells in the same frequency band and is larger than or equal
to the lower limit specified by RprtThoCSXXX. Here, XXX represents the
frequency band of a serving cell.
Adjacent cell in the frequency band different from that of the serving
cell must have the following features: BSIC of color code is valid.
Its measured field intensity ranks high among cells in the same
frequency band and is larger than or equal to the lower limit specified
by RprtThoCSXXX. Here, XXX represents the frequency band different
from that of serving cell.
Adjacent cells using other access technologies like UTRAN/FDD must
have the following features: The scrambling code of the cell is correct.
Its measured field intensity ranks high among cells with the same access
technologies and is larger than or equal to the lower limit specified
by XXXRprtThoPS. Here, XXX represents access technologies like
WCDMA/FDD.
For the priorities mentioned above, if there is vacancies for the cells with
the current priority, leave the vacancies to the adjacent cells with the next
priority. For the access technologies such as UTRAN/FDD, or frequency
band such as GSM 900 or RepPrioCS, cells with higher frequency bands
are preferred. For cells with same RepPrioCS, the cell with greater
sum of RprtThoCSXXX (or XXXRprtThoCS) and RprtOffsetCSXXX (or
Description

XXXRprtOffsetCS) is preferred.

Managed Object

Cell

Value Range and Step

Low, High

Unit

None

Default Value

Low

Default Value
Configuration Reason

This parameter is set low by default.

Configuration Rule and


Adjustment Suggestion

No modification after configuration if there is no special demands.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

0
5-682

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.15 PS adjacent cell report priority (RepPrioPS)


Full Name

PS adjacent cell report priority

Abbreviation

RepPrioPS

3GPP Name

REP_PRIORITY

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the priorities of the measurement reports from
adjacent cells. The parameter information is broadcast to an MS through
SI2quater messages.
The adjacent cell reporting is performed according to the following
priorities:
Adjacent cells with the same frequency band must have the following
features: BSIC of color code is valid; Its measured field intensity ranks
high among cells in the same frequency band and is larger than or equal
to the lower limit specified by RprtThoPSXXX. Here, XXX represents the
frequency band of a serving cell.
Adjacent cell in the frequency band different from that of the serving
cell must have the following features: BSIC of color code is valid.
Its measured field intensity ranks high among cells in the same
frequency band and is larger than or equal to the lower limit specified
by RprtThoPSXXX. Here, XXX represents the frequency band different
from that of serving cell.
Adjacent cells using other access technologies like UTRAN/FDD must
have the following features: The scrambling code of the cell is correct.
Its measured field intensity ranks high among cells with the same access
technologies and is larger than or equal to the lower limit specified
by XXXRprtThoPS. Here, XXX represents access technologies like
WCDMA/FDD.
For the priorities mentioned above, if there is vacancies for the cells with
the current priority, leave the vacancies to the adjacent cells with the next
priority. For the access technologies such as UTRAN/FDD, or frequency

Description

band such as GSM 900 or RepPrioPS, cells with higher frequency bands

5-683
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

are preferred. For cells with same RepPrioPS, the cell with greater
sum of RprtThoPSXXX (or XXXRprtThoPS) and RprtOffsetPSXXX (or
XXXRprtOffsetPS) is preferred.
Managed Object

Cell

Value Range and Step

(Low, High)

Unit

None

Default Value

Low

Default Value
Configuration Reason

Refer to the CS parameter.


For the last priority setting of the measurement report from adjacent
cells, if the cells with higher priorities are expected to report, RepPrioPS

Configuration Rule and


Adjustment Suggestion

for an adjacent cell should be set high. Then the measurement results
will be reported every time. In most cases every adjacent cell is treated
the same. Cells with low priorities does not report frequently (when
ReportRatePS is set to 1), RepPrioPS is recommended to be set with
the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.16 Target cell traffic threshold (TargetCellTrafficThs)


Full Name

Target cell traffic threshold

Abbreviation

TargetCellTrafficThs

3GPP Name

None

3GPP Reference

None
5-684

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter indicates the threshold of the traffic in a target cell.


The PS handover decision is made based on this value. If the traffic
of this target cell is higher than the threshold value, there will be no
PS handover to this cell.
Description

This parameter is used in 2G handover.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

75

Default Value

The resources should be obtained and at the same time the congestion

Configuration Reason

in target cell should be avoided.

Configuration Rule and

If the parameter is set too high, congestion will be likely to happen in

Adjustment Suggestion

the target cell.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.17 Handover threshold from macro to micro (MacroMicroHoThs)


Full Name

Handover threshold from macro to micro

Abbreviation

MacroMicroHoThs

3GPP Name

None

3GPP Reference

None

5-685
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the signal strength threshold for macro-micro


Description

handover.

Managed Object

Cell
> -48 dBm
-50..-49 dBm
...
-109..-108 dBm
-110..-109 dBm
<-110 dBm

Value Range and Step

Step: 1

Unit

dBm

Default Value

-91..-90 dBm

Default Value
Configuration Reason

In most cases, if the minimum macro-micro handover threshold is set


to 20 (-91dBm..-90 dBm), an MS can be handed over to an adjacent
cell with better level.

Configuration Rule and

In most cases, it will be easier to trigger a macro-micro handover if the

Adjustment Suggestion

threshold is set higher.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.18 Counter of handover threshold from macro to micro (MacroMicroHon)


Full Name

Counter of handover threshold from macro to micro

Abbreviation

MacroMicroHon

3GPP Name

None
5-686

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Reference

None
During a process of macro to micro handover decision determination, if N
consecutive times of measurement reports meet the conditions to conduct

Description

a macro to micro handover, the handover will be conducted.

Managed Object

Cell
1..255

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

In most cases, the handover effect will be better if N is set to 2.


If the level an adjacent cell is higher than the macro to micro handover
for consecutive Ntimes, a handover will be triggered.

Configuration Rule and


Adjustment Suggestion

If the parameter is set too high, handover will not be conducted in time
and overloaded traffic cannot be transferred;
If the parameter is set low, wrong or frequent handover will happen, thus
number of call drops will increase.
This parameter configures adjacent cells.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.19 The direction of neighbour cell for downlink rapid handover (NCellDir)
Full Name

The direction of neighbour cell for downlink rapid handover

Abbreviation

NCellDir
5-687

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

None

3GPP Reference

None
This parameter indicates the direction of an adjacent cell to the current

Description

cell. Every adjacent cell can be configured with direction information.

Managed Object

Cell
0: Any direction
1: Direction A

Value Range and Step

2: Direction B

Unit

None

Default Value

Any direction

Default Value
Configuration Reason

Sites without high-speed railway can be configured with any direction.

Configuration Rule and

In high-speed railway environment, the direction of an adjacent cell

Adjustment Suggestion

should be selected according to the network design.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Handover and Reselection->Basic Property
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.20 Downlink rapid handover threshold (DLRapidHoThs)


Full Name

Downlink rapid handover threshold

Abbreviation

DLRapidHoThs

3GPP Name

None

3GPP Reference

None

5-688
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

After measurement reports are acquired, the judgment can be made for
downlink handover caused by fast moving.
Downlink fast moving is one of the causes for handover. The judgment
process is as follows: If the latest continuous N downlink levels (without
average operation) are larger than the sum of threshold and offset,
handover should be initiated. In this case, the handover cause is
downlink fast moving. The DLRapidHoThs parameter defines the
threshold.
Description

Since the version V6.20.614b, this parameter is supported.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

10

Default Value

According to the experience of site configuration, the default value 10 is

Configuration Reason

a reasonable value for handover.


The larger the value of this parameter, the lower the possibility of

Configuration Rule and


Adjustment Suggestion

initiating handover. The smaller the value of this parameter, the higher
the possibility of initiating handover. If this parameter is configured too
large, call drops will increase. If this parameter is configured too small,
excessive handovers occur.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.21 Is the downlink rapid handover ncell (IsDLRapidHoNcell)


Full Name

Is the downlink rapid handover ncell

5-689
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

IsDLRapidHoNcell

3GPP Name

None

3GPP Reference

None
It is a parameter of adjacent cell, which is used to indicate whether the ad-

Description

jacent cell is a cell covered with a dedicated high-speed railway network.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

It is a functional parameter and is configured to "No" by default.

Configuration Rule and

Enable this switch according to network planning, for example, enable

Adjustment Suggestion

this switch for the cells to be covered with a high-speed railway network.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.7.2.1.22 Downlink rapid handover N (DLRapidHoN)


Full Name

Downlink rapid handover N

Abbreviation

DLRapidHoN

3GPP Name

None

3GPP Reference

None

5-690
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

After measurement reports are acquired, the judgment can be made for
downlink handover caused by fast moving.
Downlink fast moving is one of the causes for handover. The judgment
process is as follows: If the latest continuous N downlink levels (without
average operation) are larger than the sum of threshold and offset,
handover should be initiated. In this case, the handover cause is
Description

downlink fast moving. The DLRapidHoN parameter defines the value N.

Managed Object

Cell

Value Range and Step

1..20

Unit

None

Default Value

Default Value
Configuration Reason

The N value for downlink handover caused by fast moving must not be
configured too large, so as to ensure high requirements on handover
timeliness. Therefore, the value 2 is a reasonable value.
The larger the value of this parameter, the higher the accuracy of

Configuration Rule and

handover judgment and the lower the timeliness. The smaller the value

Adjustment Suggestion

of this parameter, the lower the accuracy of handover judgment and


the higher the timeliness.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoControl_23

Relationship

This parameter is valid only when the downlink handover caused by fast
moving is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.23 Is the directed retry ncell (IsDirectRetryCell)


Full Name

Is the directed retry ncell

Abbreviation

IsDirectRetryCell
5-691

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

Null

3GPP Reference

Null
The parameter is used to indicate whether the neighbor cell is the directed

Description

retry cell. The parameter is one of the neighbor cell parameters.

Managed Object

Neighbor Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

All the adjacent cell could be the directed retry ncell, so the default value

Configuration Reason

is Yes.

Configuration Rule and

If the network planning requires the cell to be a directed retry cell, set the

Adjustment Suggestion

parameter to "Yes".

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

5.7.2.1.24 PBGT Handover Margin of Subcell 2 (HoMarginPbgtSC2)


Full Name

PBGT Handover Margin of Subcell 2

Abbreviation

HoMarginPbgtSC2

3GPP Name

Null

3GPP Reference

Null
The parameter indicates the minimum threshold for performing PBGT

Description

handover in the second subcell.

5-692
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

CELL

Value Range and Step

0..100: indicates -24dB to 76dB

Unit

Null

Default Value

40

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

5.7.2.1.25 Rx Level Handover Margin of Subcell 2 (HoMarginRxLevSC2)


Full Name

Rx Level Handover Margin of Subcell 2

Abbreviation

HoMarginRxLevSC2

3GPP Name

Null

3GPP Reference

Null
The parameter indicates the minimum threshold for performing signal

Description

strength handover in the second subcell.

Managed Object

CELL

Value Range and Step

0..100: indicates -24dB to 76dB

Unit

Null

Default Value

40

5-693
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

5.7.2.1.26 Rx Quality Handover Margin of Subcell 2 (HoMarginRxQualSC2)


Full Name

Rx Quality Handover Margin of Subcell 2

Abbreviation

HoMarginRxQualSC2

3GPP Name

Null

3GPP Reference

Null
The parameter indicates the minimum threshold for performing quality

Description

handover in the second subcell.

Managed Object

CELL

Value Range and Step

0..100: indicates -24dB to 76dB

Unit

Null

Default Value

40

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

5-694
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

5.7.2.1.27 Min Rx Level of Subcell 2 (RxLevMinSC2)


Full Name

Min Rx Level of Subcell 2

Abbreviation

RxLevMinSC2

3GPP Name

Null

3GPP Reference

Null
The parameter indicates the neighbor cell minimum receiving intensity in

Description

the second subcell.

Managed Object

CELL
0: < -110dBm
1: -110 ~ -109 dBm
2: -109 ~ -108dBm

61: -50 ~ -49dBm


62: -49 ~ -48dBm

Value Range and Step

63: > -48dBm

Unit

Null

Default Value

15

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

5-695
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

5.7.2.1.28 Target Traffic Threshold of Subcell 2 (TargetTrafficThsSC2)


Full Name

Target Traffic Threshold of Subcell 2

Abbreviation

TargetTrafficThsSC2

3GPP Name

Null

3GPP Reference

Null

Description

The parameter specifies the limit on the traffic of the target handover cell.

Managed Object

CELL

Value Range and Step

0..100 (%)

Unit

Default Value

65

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

0
5-696

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

5.7.2.1.29 Is The Related Cell In dual- Frequency Network (IsDualFreqRltCell)


Full Name

Is The Related Cell In dual- Frequency Network

Abbreviation

IsDualFreqRltCell

3GPP Name

None

3GPP Reference

None

Description

Is The Related Cell In dual- Frequency Network

Managed Object

CELL
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value

A neighbor cell is normally not set to an associated cell of a

Configuration Reason

dual-frequency network.

Configuration Rule and


Adjustment Suggestion

If this neighbor cell has a coverage overlapped with the local cell and
is a traffic balance cell, set this neighbor cell to an associated cell of
the dual-frequency network.

Change Mode

Offline

Related features

None

Related Parameters

Inter-set
1. For the same cell, only one dual-frequency network associated cell
can be configured.
2. When setting the neighbor cell relationship between the

Relationship

dual-frequency associated cell and the local cell, set the local cell as the
dual-frequency network associated cell for the neighbor cell as well.
3. The two cells that are the dual-frequency network associated cell
should be on the same CMP module.

Related Interfaces

None

Impact on Equipment

0
5-697

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.7.2.1.30 Handover Priority Indication when serve cell powerdown (PwDownHoPriInd)


Full Name

Handover Priority Indication when serve cell powerdown

Abbreviation

PwDownHoPriInd

3GPP Name

None

3GPP Reference

None

Description

Handover Priority Indication when serve cell powerdown

Managed Object

CELL
[0,1]

Value Range and Step

step: 1

Unit

None

Default Value

Default Value
Configuration Reason

System choose the handover target cell automatically.

Configuration Rule and

IF user want to customize the handover target cell, the parameter need

Adjustment Suggestion

to be configured as 1.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Site config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection
5-698

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.7.2.1.31 Related Cell DN


Full Name

Related Cell DN

Abbreviation

None

3GPP Name

None

3GPP Reference

None
Users can click the Select button to select cell or external cell from the
pop-up interface. The internal cell is identified by siteid-btsid, while the

Description

external cell is identified by ECID.

Managed Object

Cell

Value Range and Step

None

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None
5-699

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.7.2.1.32 Is related cell (IsRelatedCell)


Full Name

Is related cell

Abbreviation

IsRelatedCell

3GPP Name

None

3GPP Reference

None
Only the cell related to the serving cell can be a candidate in rapid fading
handover. This is a parameter of adjacent cell and is used to indicate

Description

whether adjacent cell is related to the serving cell.

Managed Object

Cell
0: Noi

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional parameter.

Configuration Rule and

This switch is enabled if it is planned as a candidate in rapid fading

Adjustment Suggestion

handover as needed.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Handover and Reselection->Basic Property
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.33 Is handover forced neighbor cell (IsHoForceNcell)


Full Name

Is handover forced neighbor cell

Abbreviation

IsHoForceNcell
5-700

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

None

3GPP Reference

None
In the case of 1800 M and 900 M network site sharing, it is better to
handover subscribers of 900 M network to 1800 M network. At this time,
force traffic transfer can be conducted.
Force traffic transfer is the last method for on-site traffic adjustment. It
is used in dual-frequency networking. The direction of the forced traffic
transfer is definite, that is, 1800 M sector in the same direction. To avoid
impact on other cells, the force traffic transfer is performed only for a

Description

specific target cell.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

In a 900 M and 1800 M site sharing cell, the 1800 Mcell can be set to

Configuration Reason

force traffic transfer cell. In most cases the parameter is set to "No".

Configuration Rule and

This parameter should be set for the target cell in a handover including

Adjustment Suggestion

force traffic transfer.

Change Mode

Offline

Related features

ZGO-02-02-003 Directed-Shift Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.34 CCN support (CCNSupport)


Full Name

CCN support
5-701

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

CCNSupport

3GPP Name

CCN_ACTIVE

3GPP Reference

3GPP TS44.060 V5.19.0


The CCN_ACTIVE parameter is used in GPRS Cell Options IE of SI13
on BCCH at the network side, to indicate whether CCN mode is applied
when a reselection is conducted from the current cell to a GSM adjacent
cell. If GPRS Cell Options IE does not include the CCN_ACTIVE
parameter, or the CCN_ACTIVE parameter is not enabled, MS will
not use CCN mode. If the CCN_ACTIVE parameter is enabled and
the cell reselection will be performed to a GSM cell, check that the
CCN_SUPPORTED exists in an adjacent cell;
If the CCN_SUPPORTED does not exist, MS can use CCN mode;
If the CCN_SUPPORTED exists and it is disabled, MS cannot use CCN
mode;
If the CCN_SUPPORTED exists and it is enabled, MS can use CCN
mode;
The network side can indicate whether the CCN_ACTIVE parameter
is enabled for a particular MS through Packet Measurement Order
messages. It can also indicate whether the CCN_ACTIVE parameter
is enabled for a particular MS target cell through Packet Cell Change
Order or PS Handover Command messages. An MS will use CCN mode

Description

under NC0 and NC1 modes.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.


If the CCN Active function is enabled and the parameter of the adjacent
cell is set to "Yes", CCN mode is used during the reselection to this

Configuration Rule and

cell; if the parameter is set to "No", CCN mode will not be used during

Adjustment Suggestion

the reselection. In most cases, CCN Active should be set to enable


this function and the CCN Support function should be enabled in the
adjacent cell.

Change Mode

Offline

Related features

ZGO-02-02-010 Network-assisted Cell Change

Related Parameters

[BSC]NACCSupport
[Cell]CCNActive
[Cell]SIStatusInd

5-702
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Relationship

If NACC function is enabled, CCNActive/SIStatusInd/CCNSupport must


be enabled at the same time.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.35 The threshold list of C/I limited cell (CILimitedThs)


Full Name

The threshold list of C/I limited cell

Abbreviation

CILimitedThs

3GPP Name

None

3GPP Reference

None
This parameter indicates the threshold that an adjacent cell is limited by
the C/I of C/I limited cell. The adjacent cell belongs to a service cell.
The adjacent cell will be restricted and handover cannot be performed
towards it, when the C/I value of its limited cell and a service cell is
greater than the threshold that the adjacent cell is limited by the limited

Description

cell.

Managed Object

Cell

Value Range and Step

For C/I limited adjacent cells, the value range is 0..63.

Unit

None

Default Value

63
The handover algorithm is the algorithm used in special condition, so

Default Value

the default value is set to a maximum value. That is, the restriction does

Configuration Reason

not take effect. It can be adjusted to a smaller value according to the


on-site conditions.
The higher the threshold is, the more difficult it is for limited cell to restrict

Configuration Rule and


Adjustment Suggestion

the adjacent cell, and the easier handover is towards the adjacent
cell.Generally, the purpose of setting limited cell for an adjacent cell is to
avoid handover towards the adjacent cell. Therefore, it is suggested to
set the threshold to a relatively low value.

5-703
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Handover and Reselection->Basic Property
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.36 The number of C/I limited cell (CILimitedNum)


Full Name

The number of C/I limited cell

Abbreviation

CILimitedNum

3GPP Name

None

3GPP Reference

None
This parameter indicates the number of adjacent cells to which handover
from the serving cell is limited. If the number is 0, handover from the

Description

serving cell to this adjacent cell is not limited by other adjacent cells.

Managed Object

Cell
0..5

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The handover algorithm is used under the special scenario, so the

Configuration Reason

default value 0 is disabled.


Generally, it is recommended not to set C/I limited cell for the adjacent

Configuration Rule and

cell.At such areas as the intersection and crossing, the coverage cells

Adjustment Suggestion

are configured with C/I limited cell, to prevent handover from being
performed to these cells because the signal is unstable.

Change Mode

Offline

5-704
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.1.37 The objectID list of C/I limited cell (LimitedObjectId)


Full Name

The objectID list of C/I limited cell

Abbreviation

LimitedObjectId

3GPP Name

None

3GPP Reference

None
This parameter indicates the location object ID of C/I limited cell in the

Description

adjacent cell list of the serving cell.

Managed Object

Cell

Value Range and Step

For C/I limited adjacent cells, the value range is 0..255.

Unit

None

Default Value

Default Value

The default value can be configured as required. 0 is the initial value,

Configuration Reason

so it is taken as the default value.

Configuration Rule and

According to actual condition on site, you can configure the adjacent cell

Adjustment Suggestion

object ID of C/I limited cell in the serving cell for one adjacent cell.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None
5-705

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.2 PS Handover Parameters


5.7.2.2.1 Counter of macro to micro handover (MacroMicroHoN_PS)
Full Name

Counter of macro to micro handover

Abbreviation

MacroMicroHoN_PS

3GPP Name

Internal

3GPP Reference

None
The handover from macro-cell to micro-cell is mainly applied to a two-layer
network. That is, the slowly moving MS hands over from the macro-cell
layer to the micro-cell layer. It judges whether the condition allows the
MS moving slowly performs PS handover to a cell one-layer lower than
the current cell. The condition is the level of adjacent cell exceeds the
threshold for N times. This parameter is to count the adjacent cell level
higher than the threshold when PS handover occurs between the macro

Description

cell and the mico cell.

Managed Object

Neighbor Cell
1..255

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value to 2, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover
5-706

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.2.2 Threshold of macro to micro handover (MacroMicroHoThs_PS)


Full Name

Threshold of macro to micro handover

Abbreviation

MacroMicroHoThs_PS

3GPP Name

Internal

3GPP Reference

None
The handover from macro-cell to micro-cell is mainly applied to a twolayer network. That is, the slowly moving MS hands over from the macrocell layer to the micro-cell layer. It judges whether the condition allows
the MS moving slowly performs PS handover to a cell one-layer lower
than the current cell. The condition is the level of adjacent cell exceeds
the threshold for N times. This parameter is the threshold for cell signal
strength when PS handover occurs between the macro cell and the mico

Description

cell.

Managed Object

Neighbor Cell
0: <-110dBm
1: -110 ~-109 dBm
2: -109 ~ -108dBm
...
61: -50 ~ -49dBm
62: -49~ -48dBm

Value Range and Step

63: > -48dBm

Unit

None

Default Value

20

5-707
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Usually, when other types of handover are not triggered, -90 dBm is

Configuration Reason

enough to initiate macro-micro handver, to balance traffc.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.2.3 Traffic threshold of target cell (TargetTrafficThs_PS)


Full Name

Traffic threshold of target cell

Abbreviation

TargetTrafficThs_PS

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the threshold of the traffic in a target cell. The PS
handover arbitration is made on based on this value. If the traffic of this
target cell is higher than the threshold value, there will be no PS handover

Description

to this cell.

Managed Object

Neighbor Cell
0..100

Value Range and Step

Step: 1

Unit

Default Value

70

Default Value

This parameter can be set to ensure enough resources used for

Configuration Reason

handover.

5-708
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.2.4 Margin of PBGT handover (HoMarginPbgt_PS)


Full Name

Margin of PBGT handover

Abbreviation

HoMarginPbgt_PS

3GPP Name

Internal

3GPP Reference

None
PS handover decision can be made at receiving the related average values. The PBGT_PS value of an adjacent cell is also one of the causes
for PS handover. The decision process is as follows: If the PBGT_PS
value of an adjacent cell is higher than the relevant threshold of this cell,
PS handover should be performed to find a more suitable cell. This parameterr is the threshold that must be used in the PS handover decision

Description

to hand over from an adjacent cell to the local cell through PBGT.

Managed Object

Neighbor Cell
0: -24dB
1: -23dB
2: -22dB
...
46: 22 dB
47: 23dB

Value Range and Step

48: 24dB
5-709

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

dB

Default Value

30

Default Value

Good signal strength can be ensured when PBGT handover is

Configuration Reason

conducted.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Handover and Reselection->PSHOC Parameter
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.2.5 Margin of RX handover (HoMarginRxLev_PS)


Full Name

Margin of RX handover

Abbreviation

HoMarginRxLev_PS

3GPP Name

Internal

3GPP Reference

None
PS handover decision can be made at receiving the related average values. In a handover caused by level changes, adjacent cells shall be
screened and sequenced. This parameter is the threshold that must be
used in the handover decision for a PS handover from the adjacent cell

Description

to the local cell through signal strength.

Managed Object

Neighbor Cell

5-710
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

0: -24dB
1: -23dB
2: -22dB
...
46: 22 dB
47: 23dB
Value Range and Step

48: 24dB

Unit

dB

Default Value

30

Default Value

Good signal strength can be ensured when handover caused by signal

Configuration Reason

strength is conducted.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.2.6 Margin of quality handover (HoMarginRxQual_PS)


Full Name

Margin of quality handover

Abbreviation

HoMarginRxQual_PS

3GPP Name

Internal

3GPP Reference

None

5-711
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

PS handover decision can be made at receiving the related average values. In handover caused by the quality, adjacent cells shall be screened
and sequenced. This parameter is the threshold that must be used in the
handover decision for a PS handover from the adjacent cell to the local
Description

cell through signal quality.

Managed Object

Neighbor Cell
0: -24dB
1: -23dB
2: -22dB
...
46: 22 dB
47: 23dB

Value Range and Step

48: 24dB

Unit

dB

Default Value

30

Default Value

Good signal strength can be ensured when handover caused by signal

Configuration Reason

quality is conducted.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.2.2.7 Minimum RX level (RxLevMin_PS)


Full Name

Minimum RX level

5-712
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Abbreviation

RxLevMin_PS

3GPP Name

Internal

3GPP Reference

None
This parameter defines the minimum receiving strength level (on PBCCH)
required by MS to handover to this cell. It is one of the parameters to
decide preferred cells during handover control. MS in a serving cell constantly monitors the signal strength on PBCCH of adjacent cells. Adjacent
cells with the receiving intensity level higher than the minimum value de-

Description

fined by this parameter are candidates for handover.

Managed Object

Neighbor Cell
0: <-110dBm
1: -110..-109 dBm
2: -109..-108dBm
...
61: -50..-49dBm
62: -49..-48dBm

Value Range and Step

63: > -48dBm

Unit

dB

Default Value

15

Default Value
Configuration Reason

This parameter is relevant to PBCCH. Keep the default setting.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->PSHOC Parameter

Parameter Modifying
Version

None

5-713
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.7.2.2.8 Is related cell (IsRelatedCell_PS)


Full Name

Is related cell

Abbreviation

IsRelatedCell_PS

3GPP Name

Internal

3GPP Reference

None
Only the cell related to the serving cell can be a candidate in rapid fading
PS handover. This is a parameter of an adjacent cell and is used to indi-

Description

cate whether an adjacent cell is related to the serving cell.

Managed Object

Neighbor Cell
0: Yes

Value Range and Step

1: No

Unit

None

Default Value

Default Value
Configuration Reason

Related to quick handover. Not configured by default.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-714
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.7.2.2.9 Handover priority (HoPriority_PS)


Full Name

Handover priority

Abbreviation

HoPriority_PS

3GPP Name

Internal

3GPP Reference

None
Cell priorities should be taken into consideration when candidate cells are
sequenced during PS handover. Therefore, there are three decisive factors to sequence candidate cells: priority, traffic, and radio communication
environment. Priority and traffic have the most impact on cell sequencing.
If they lead to the same result, sequence cells by radio conditions. The

Description

priority of a cell becomes higher with the increasing of this value.

Managed Object

Neighbor Cell
0..7 (0 means the lowest priority)

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The priority gets the middle value by default.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-715
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.7.2.2.10 Max TX power of MS (MsTxPwrMax_PS)


Full Name

Max TX power of MS

Abbreviation

MsTxPwrMax_PS

3GPP Name

Internal

3GPP Reference

None

Description

cell when on PBCCH.

Managed Object

Neighbor Cell

This parameter indicates the highest power allowed by MS in an adjacent

0..31
Value Range and Step

Step: 1

Unit

dBm

Default Value

Default Value
Configuration Reason

This parameter is relevant to PBCCH. Keep the default setting.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover and Reselection->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-716
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.7.3 Adjacent Cell Handover Parameters


5.7.3.1 Basic Property
5.7.3.1.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None
This parameter means the site ID. It cannot be modified.

Description

Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell Han-

OMC Access Path


Parameter

Modifying

Version
Parameter
Detail

dover->Basic Property

None
Modifying
None

5.7.3.1.2 BTS ID (BtsId)


Full Name

BTS ID
5-717

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell
1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell Han-

OMC Access Path

dover->Basic Property

5-718
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter

Modifying

Version
Parameter

None
Modifying

Detail

None

5.7.3.1.3 Adjacent cell handover object ID (HoObjectId)


Full Name

Adjacent cell handover object ID

Abbreviation

HoObjectId

3GPP Name

None

3GPP Reference

None

Description

This parameter is a unique identification of adjacent cell handover object.

Managed Object

Cell
1..64

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

1: the first value

Configuration Rule and


Adjustment Suggestion

This parameter is dependant on the actual configuration.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-719
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.7.3.1.4 Priority of handover (HoPriority)


Full Name

Priority of handover

Abbreviation

HoPriority

3GPP Name

None

3GPP Reference

None
According to GSM specifications, static cell priority should be considered
when candidate cells are sequenced. Therefore, there are three decisive
factors to sequence candidate cells: priority, traffic, and radio communication environment. Static priority and traffic have the most impact on cell
sequencing. If they lead to the same result, sequence cells by radio con-

Description

ditions. The priority of a cell is higher if this value is set higher.

Managed Object

Cell
0..7

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

In most cases, this parameter is set to 3, and the cell priority are the

Configuration Reason

same.

Configuration Rule and

The priority of a cell becomes higher if the parameter is set higher, and

Adjustment Suggestion

the sequence of cells will be impacted during handover process.

Change Mode

Offline

Related features

ZGO-02-02-002 Dynamic Handover Priority Algorithm

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-720
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.7.3.1.5 MAX power level of MS (MsTxPwrMax)


Full Name

MAX power level of MS

Abbreviation

MsTxPwrMax

3GPP Name

MS_TXPWR_MAX

3GPP Reference

3GPP TS 45.008 V5.22.0


During the communication between MS and BTS, the transmission
power of MS is controlled by the network. The network sets the power
for MS through the power command and the command is transmitted on
SACCH (SACCH has 2 header bytes, one is the power control byte and
the other is the TA byte).
An MS sets the specified output transmission power according to the
power control header extracted from the downlink SACCH. An MS uses
the closest possible output power if it cannot output the specified power.
MS max power level is also a parameter used by BSC to calculate

Description

PBGT value.

Managed Object

Cell
0 .. 31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The maximum power for most MSs

Configuration Rule and


Adjustment Suggestion

For 900 M, set the parameter to 5; for 1800 M, set it to 0.

Change Mode

Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

5-721
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.1.6 MIN power level for handover access (RxLevMin)


Full Name

MIN power level for handover access

Abbreviation

RxLevMin

3GPP Name

RXLEV_ACCESS_MIN

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter defines the minimum receiving strength level (on BCCH)
required for MS to handover to this cell. It is one of the parameters to
decide preferred cells during handover control. MS in the serving cell
constantly monitors the signal intensity on BCCH of adjacent cells.
Adjacent cells with the receiving intensity level higher than the minimum
value defined by this parameter are candidates for handover.
It is advised to set this parameter to approximate MS receiving sensitivity.
For some cells with traffic overload, increase the minimum access level
to decrease C1 and C2 value of the cell, and the cell coverage range
decreases at the same time. Setting the minimum access level too large
will cause crossover area of cells to become "dead area. The level
should not exceed -90 dBm for cell traffic balancing. At the preliminary
running stage of the network, this parameter can be usually set as 10
(that is, -101 dBm .. -100 dBm) or lower, which is higher than the MS
receiving sensitivity -102 dBm. However, when the network capacity is
expanded or the radio coverage in a cell is not a problem, this parameter

Description

of the cell can be increased by 2.

Managed Object

Cell
0.. 63
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
2: -109 dBm .. -108 dBm;
...
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

15

Default Value
Configuration Reason

This parameter is set based on experience.

5-722
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

The value of this parameter must be higher than the minimum access
level of the corresponding adjacent cell, and the value should also be
Configuration Rule and

higher or equal to the downlink level handover threshold, otherwise

Adjustment Suggestion

frequent handover or reselection will happen.


Improper settings for this parameter will bring up negative impacts on
handover, call drop rate and road test coverage.

Change Mode

Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.1.7 MIN threshold of signal level for handover on PBGT (HoMarginPbgt)


Full Name

MIN threshold of signal level for handover on PBGT

Abbreviation

HoMarginPbgt

3GPP Name

None

3GPP Reference

None
According to GSM specifications, handover decisions will be made after
a series of average values have been obtained.
This parameter defines the threshold used to determine PBGT handover

Description

from an adjacent cell to local cell.

Managed Object

Cell

5-723
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0..100
0: -24 dBd;
1: -23 dB;
...
100: 76 dB
Value Range and Step

Step: 1

Unit

None

Default Value

30

Default Value

The value of a target cell should be set higher to ensure that a handover

Configuration Reason

is conducted correctly.
If the parameter is set high, it is difficult to handover to the target cell; if
set low, it is easier to handover to the target cell. If the parameter is set
lower than 24, the handover to the target cell can be triggered even if the
target cell level is lower than the original cell level.

Configuration Rule and

Raise the value of this parameter to reduce number of times of

Adjustment Suggestion

handovers in the area with frequent handovers;


Lower the value of this parameter in the area with blocks with shadows
to make the handovers easier to happen;
Improper settings for this parameter will bring up negative impacts on
handover, call drop rate and road test coverage.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.1.8 MIN threshold of signal level for handover on power level (HoMarginRxLev)
Full Name

MIN threshold of signal level for handover on power level

5-724
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Abbreviation

HoMarginRxLev

3GPP Name

None

3GPP Reference

None
According to GSM specifications, handover decisions will be made after
a series of average values have been obtained. In a handover caused
by level changes, adjacent cells shall be screened and sequenced. This
parameter defines the signal strength threshold to determine handover

Description

from adjacent cell to local cell.

Managed Object

Cell
0..100
0: -24 dB;
1: -23 dB;
...
100: 76 dB

Value Range and Step

Step: 1

Unit

None

Default Value

30

Default Value

In most cases, if the minimum handover threshold is set to 30, an MS

Configuration Reason

can be handed over to an adjacent cell with better level.

Configuration Rule and


Adjustment Suggestion

It becomes easier to trigger a handover if the threshold value is set lower.

Change Mode

Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-725
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.7.3.1.9 MIN threshold of signal level for handover on quality (HoMarginRxQual)


Full Name

MIN threshold of signal level for handover on quality

Abbreviation

HoMarginRxQual

3GPP Name

None

3GPP Reference

None
According to GSM specifications, handover decisions will be made after
a series of average values have been obtained. In handover based on
quality, adjacent cells shall be screened and sequenced. This parameter
defines the signal quality threshold to determine handover from an adja-

Description

cent cell to the local cell.

Managed Object

Cell
0..100
0: -24 dB;
1: -23 dB;
...
100: 76 dB

Value Range and Step

Step: 1

Unit

None

Default Value

30

Default Value

In most cases, if the minimum handover threshold is set to 30, an MS

Configuration Reason

can be handed over to an adjacent cell with better level.

Configuration Rule and


Adjustment Suggestion

It becomes easier to trigger a handover if the threshold value is set lower.

Change Mode

Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None
5-726

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.7.3.1.10 MAX level difference of force handover (MaxForceHoDiff)


Full Name

MAX level difference of force handover

Abbreviation

MaxForceHoDiff

3GPP Name

None

3GPP Reference

None
Directed handover is performed only for one designated cell and it is restricted by a tolerable level difference. This tolerable level difference is
lower than PBGT handover threshold in reverse direction, thus to avoid

Description

oscillating handover.

Managed Object

Cell
0..48
(-24 dBm .. 24 dBm)

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The level difference between two cells should not be too big or too small.

Configuration Reason

9 is a recommended value.

Configuration Rule and


Adjustment Suggestion

The lower the level difference. the more likely the handover will happen.
The parameter cannot be set too low, otherwise frequent oscillating
handovers will be caused.

Change Mode

Offline

Related features

ZGO-02-02-003 Directed-Shift Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

5-727
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.7.3.1.11 Handover force resource threshold (HoForceResThs)


Full Name

Handover force resource threshold

Abbreviation

HoForceResThs

3GPP Name

None

3GPP Reference

None
The force migration will not cause congestion in a cell, so a transfer
reserved resource threshold is set. When resource of object cell is lower
than the congestion threshold, forced handover can be implemented.
The formula to calculate the resource threshold is: 100 - currentTCH
load in a cell >= transfer reserved resource threshold
Current TCH load in a cell = total number of busy TCH *100 / (total
number of busy TCH + total number of idle TCH), the total number

Description

includes the dynamic ones and static ones.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

40

Default Value

The threshold should not be too high or too low. 40 is the recommended

Configuration Reason

value.

Configuration Rule and

The threshold cannot be set too low to avoid force transfer of overloaded

Adjustment Suggestion

traffic in a cell.

Change Mode

Offline

Related features

ZGO-02-02-003 Directed-Shift Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

5-728
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.1.12 Neighboring cell layer (NCellLayer)


Full Name

Neighboring cell layer

Abbreviation

NCellLayer

3GPP Name

None

3GPP Reference

None
This parameter provides the handover policies in multi-layer network
technology and dual-frequency network technology. Multi-layer radio
coverage can be formed in the same physical area.
The handover policies will not be detailed in this manual. In brief, limiting
the PBGT handover defined in the specifications at one layer can reduce
the number of handovers during the call, thus improving the system
reliability and communication quality. The policy of handover between
upper layers and lower layers mainly depends on the moving speed of
MS. An MS at higher moving speed will try to stay at the upper layers,
and an MS at lower moving speed will try to enter the lower layers. Only
in the case of PBGT handover and emergency, will the undefined cell of
the service area be considered as a candidate cell.
Same layer of the home cell: Adjacent cell and local cell are in the
same layer (PBGT handover possible); Upper layer of the home cell:
Adjacent cell is the upper layer of local cell ; Lower layer of the home
cell: Adjacent cell is the lower layer of local cell; Refer to the Appendix

Description

Cell Layer Number Setup, for details.

Managed Object

Cell
0: not defined
1: same level as that of the current cell
2: upper layer of this cell

Value Range and Step

3: lower layer of this cell

Unit

None

Default Value

At the same layer as that of this cell

Default Value

In most cases configure the parameter to same level. For the cells that

Configuration Reason

have enabled macro-micro handover, different levels can be configured.

Configuration Rule and


Adjustment Suggestion

In most cases configure the parameter to same level.

Change Mode

Offline

5-729
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

ZGO-02-02-001 Handover Between Macro- and Micro-cells


Related features

ZGO-05-02-008 Multi-Layer Cell Structure

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.1.13 CS adjacent cell report priority (RepPrioCS)


Full Name

CS adjacent cell report priority

Abbreviation

RepPrioCS

3GPP Name

REP_PRIORITY

3GPP Reference

3GPP TS 45.008 V5.22.0


The adjacent cell reporting is performed according to the following
priorities:
Adjacent cells with the same frequency band must have the following
features: BSIC of color code is valid; Its measured field intensity ranks
high among cells in the same frequency band and is larger than or equal
to the lower limit specified by RprtThoCSXXX. Here, XXX represents the
frequency band of a serving cell.
Adjacent cell in the frequency band different from that of the serving
cell must have the following features: BSIC of color code is valid.
Its measured field intensity ranks high among cells in the same
frequency band and is larger than or equal to the lower limit specified
by RprtThoCSXXX. Here, XXX represents the frequency band different
from that of serving cell.
Adjacent cells using other access technologies like UTRAN/FDD must
have the following features: The scrambling code of the cell is correct.
Its measured field intensity ranks high among cells with the same access

Description

technologies and is larger than or equal to the lower limit specified

5-730
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

by XXXRprtThoCS. Here, XXX represents access technologies like


WCDMA/FDD.
For the priorities mentioned above, if there is vacancies for the cells with
the current priority, leave the vacancies to the adjacent cells with the next
priority. For the access technologies such as UTRAN/FDD, or frequency
band such as GSM 900 or RepPrioCS, cells with higher frequency bands
are preferred. For cells with same RepPrioCS, the cell with greater
sum of RprtThoCSXXX (or XXXRprtThoCS) and RprtOffsetCSXXX (or
XXXRprtOffsetCS) is preferred.
Managed Object

Cell

Value Range and Step

Low, High

Unit

None

Default Value

Low

Default Value
Configuration Reason

This parameter is set low by default.

Configuration Rule and


Adjustment Suggestion

No modification after configuration if there is no special demands.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.1.14 Target cell traffic threshold (TargetCellTrafficThs)


Full Name

Target cell traffic threshold

Abbreviation

TargetCellTrafficThs

3GPP Name

None

5-731
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

None
This parameter indicates the threshold of the traffic in a target cell.
The PS handover decision is made based on this value. If the traffic
of this target cell is higher than the threshold value, there will be no
PS handover to this cell.

Description

This parameter is used in 2G handover.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

75

Default Value

The resources should be obtained and at the same time the congestion

Configuration Reason

in target cell should be avoided.

Configuration Rule and

If the parameter is set too high, congestion will be likely to happen in

Adjustment Suggestion

the target cell.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.1.15 Handover threshold from macro to micro (MacroMicroHoThs)


Full Name

Handover threshold from macro to micro

Abbreviation

MacroMicroHoThs

3GPP Name

None

3GPP Reference

None

5-732
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter indicates the signal strength threshold for macro-micro


Description

handover.

Managed Object

Cell
0..63
> -48 dBm
-50..-49 dBm
...
-109..-108 dBm
-110..-109 dBm
< -110 dBm

Value Range and Step

Step: 1

Unit

dBm

Default Value

-91..-90 dBm

Default Value
Configuration Reason

In most cases, if the minimum macro-micro handover threshold is set


to 20 (-91dBm..-90 dBm), an MS can be handed over to an adjacent
cell with better level.

Configuration Rule and

In most cases, it will be easier to trigger a macro-micro handover if the

Adjustment Suggestion

threshold is set higher.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.1.16 Counter of handover threshold from macro to micro (MacroMicroHoN)


Full Name

Counter of handover threshold from macro to micro

Abbreviation

MacroMicroHoN

5-733
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

None

3GPP Reference

None
The N value for macro-micro (also P value) The macro-micro handover

Description

make lower speed MSs handover to the cells in lower levels.

Managed Object

Cell
1..255

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to apply this configuration to ensure the precise and

Configuration Reason

quick handover.

Configuration Rule and

The handover is has more preciseness and lower real-time performance

Adjustment Suggestion

if the value becomes higher.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.1.17 The direction of neighbour cell for downlink rapid handover (NCellDir)
Full Name

The direction of neighbour cell for downlink rapid handover

Abbreviation

NCellDir

3GPP Name

None

3GPP Reference

None
This parameter indicates the direction of an adjacent cell to the current

Description

cell. Every adjacent cell can be configured with direction information.


5-734

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Cell
0: Any direction
1: Direction A

Value Range and Step

2: Direction B

Unit

None

Default Value

Any direction

Default Value
Configuration Reason

Sites without high-speed railway can be configured with any direction.

Configuration Rule and

In high-speed railway environment, the direction of an adjacent cell

Adjustment Suggestion

should be selected according to the network design.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.1.18 Downlink rapid handover threshold (DLRapidHoThs)


Full Name

Downlink rapid handover threshold

Abbreviation

DLRapidHoThs

3GPP Name

None

3GPP Reference

None

5-735
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

After measurement reports are acquired, the judgment can be made for
downlink handover caused by fast moving.
Downlink fast moving is one of the causes for handover. The judgment
process is as follows: If the latest continuous N downlink levels (without
average operation) are larger than the sum of threshold and offset,
handover should be initiated. In this case, the handover cause is
downlink fast moving. The DLRapidHoThs parameter defines the
threshold.
Description

Since the version V6.20.614b, this parameter is supported.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

10

Default Value

According to the experience of site configuration, the default value 10 is

Configuration Reason

a reasonable value for handover.


The larger the value of this parameter, the lower the possibility of

Configuration Rule and


Adjustment Suggestion

initiating handover. The smaller the value of this parameter, the higher
the possibility of initiating handover. If this parameter is configured too
large, call drops will increase. If this parameter is configured too small,
excessive handovers occur.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.1.19 Is the downlink rapid handover ncell (IsDLRapidHoNcell)


Full Name

Is the downlink rapid handover ncell

5-736
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Abbreviation

IsDLRapidHoNcell

3GPP Name

None

3GPP Reference

None
It is a parameter of adjacent cell, which is used to indicate whether the ad-

Description

jacent cell is a cell covered with a dedicated high-speed railway network.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

It is a functional parameter and is configured to "No" by default.

Configuration Rule and

Enable this switch according to network planning, for example, enable

Adjustment Suggestion

this switch for the cells to be covered with a high-speed railway network.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

iBSCV6.20.615

Parameter Modifying
Detail

New

5.7.3.1.20 Downlink rapid handover N (DLRapidHoN)


Full Name

Downlink rapid handover N

Abbreviation

DLRapidHoN

3GPP Name

None

3GPP Reference

None

5-737
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

After measurement reports are acquired, the judgment can be made for
downlink handover caused by fast moving.
Downlink fast moving is one of the causes for handover. The judgment
process is as follows: If the latest continuous N downlink levels (without
average operation) are larger than the sum of threshold and offset,
handover should be initiated. In this case, the handover cause is
Description

downlink fast moving. The DLRapidHoN parameter defines the value N.

Managed Object

Cell

Value Range and Step

1..20

Unit

None

Default Value

Default Value
Configuration Reason

The N value for downlink handover caused by fast moving must not be
configured too large, so as to ensure high requirements on handover
timeliness. Therefore, the value 2 is a reasonable value.
The larger the value of this parameter, the higher the accuracy of

Configuration Rule and

handover judgment and the lower the timeliness. The smaller the value

Adjustment Suggestion

of this parameter, the lower the accuracy of handover judgment and


the higher the timeliness.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[Cell]HoControl_23

Relationship

This parameter is valid only when the downlink handover caused by fast
moving is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.1.21 Is the directed retry ncell (IsDirectRetryCell)


Full Name

Is the directed retry ncell

Abbreviation

IsDirectRetryCell
5-738

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Name

Null

3GPP Reference

Null
The parameter is used to indicate whether the neighbor cell is the directed

Description

retry cell. The parameter is one of the neighbor cell parameters.

Managed Object

Neighbor Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

All the adjacent cell could be the directed retry ncell, so the default value

Configuration Reason

is Yes.

Configuration Rule and

If the network planning requires the cell to be a directed retry cell, set the

Adjustment Suggestion

parameter to "Yes".

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

5.7.3.1.22 PBGT Handover Margin of Subcell 2 (HoMarginPbgtSC2)


Full Name

PBGT Handover Margin of Subcell 2

Abbreviation

HoMarginPbgtSC2

3GPP Name

Null

3GPP Reference

Null
The parameter indicates the minimum threshold for performing PBGT

Description

handover in the second subcell.


5-739

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

CELL

Value Range and Step

0..100: indicates -24dB to 76dB

Unit

dB

Default Value

40

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

5.7.3.1.23 Rx Level Handover Margin of Subcell 2 (HoMarginRxLevSC2)


Full Name

Rx Level Handover Margin of Subcell 2

Abbreviation

HoMarginRxLevSC2

3GPP Name

Null

3GPP Reference

Null
The parameter indicates the minimum threshold for performing signal

Description

strength handover in the second subcell.

Managed Object

CELL

Value Range and Step

0..100: indicates -24dB to 76dB

Unit

dB

Default Value

40

5-740
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

5.7.3.1.24 Rx Quality Handover Margin of Subcell 2 (HoMarginRxQualSC2)


Full Name

Rx Quality Handover Margin of Subcell 2

Abbreviation

HoMarginRxQualSC2

3GPP Name

Null

3GPP Reference

Null
The parameter indicates the minimum threshold for performing quality

Description

handover in the second subcell.

Managed Object

CELL

Value Range and Step

0..100: indicates -24dB to 76dB

Unit

dB

Default Value

40

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

5-741
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

5.7.3.1.25 Min Rx Level of Subcell 2 (RxLevMinSC2)


Full Name

Min Rx Level of Subcell 2

Abbreviation

RxLevMinSC2

3GPP Name

Null

3GPP Reference

Null
The parameter indicates the neighbor cell minimum receiving intensity in

Description

the second subcell.

Managed Object

CELL
0: < -110dBm
1: -110 ~ -109 dBm
2: -109 ~ -108dBm

61: -50 ~ -49dBm


62: -49 ~ -48dBm

Value Range and Step

63: > -48dBm

Unit

dBm

Default Value

15

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

5-742
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

5.7.3.1.26 Target Traffic Threshold of Subcell 2 (TargetTrafficThsSC2)


Full Name

Target Traffic Threshold of Subcell 2

Abbreviation

TargetTrafficThsSC2

3GPP Name

Null

3GPP Reference

Null

Description

The parameter specifies the limit on the traffic of the target handover cell.

Managed Object

CELL

Value Range and Step

0..100 (%)

Unit

Default Value

65

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

5-743
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

5.7.3.1.27 Is The Related Cell In dual- Frequency Network (IsDualFreqRltCell)


Full Name

Is The Related Cell In dual- Frequency Network

Abbreviation

IsDualFreqRltCell

3GPP Name

None

3GPP Reference

None

Description

Is The Related Cell In dual- Frequency Network

Managed Object

CELL
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value

A neighbor cell is normally not set to an associated cell of a

Configuration Reason

dual-frequency network.

Configuration Rule and


Adjustment Suggestion

If this neighbor cell has a coverage overlapped with the local cell and
is a traffic balance cell, set this neighbor cell to an associated cell of
the dual-frequency network.

Change Mode

Offline

Related features

None

Related Parameters

Inter-set
1. For the same cell, only one dual-frequency network associated cell

Relationship

can be configured.
2. The two cells that are the dual-frequency network associated cell
should be on the same CMP module.

Related Interfaces

None

Impact on Equipment

Impact on service

5-744
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork->BSC Managed Element->Config SetBSC
Function->Site Config->Site->Cell->Adjacent Cell Handover

Parameter Modifying
Version

iBSCV6.20.712b

Parameter Modifying
Detail

New

5.7.3.1.28 Handover Priority Indication when serve cell powerdown (PwDownHoPriInd)


Full Name

Handover Priority Indication when serve cell powerdown

Abbreviation

PwDownHoPriInd

3GPP Name

None

3GPP Reference

None

Description

Handover Priority Indication when serve cell powerdown

Managed Object

CELL
[0,1]

Value Range and Step

step: 1

Unit

None

Default Value

Default Value
Configuration Reason

System choose the handover target cell automatically.

Configuration Rule and

IF user want to customize the handover target cell, the parameter need

Adjustment Suggestion

to be configured as 1.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork->BSC Managed Element->Config SetBSC


Function->Site Config->Site->Cell->Adjacent Cell Handover

Parameter Modifying
Version

iBSCV6.20.712a

5-745
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

New

5.7.3.1.29 Related Cell DN


Full Name

Related Cell DN

Abbreviation

None

3GPP Name

None

3GPP Reference

None
Users can click the Select button to select cell or external cell from the
pop-up interface. The internal cell is identified by siteid-btsid, while the

Description

external cell is identified by ECID.

Managed Object

Cell

Value Range and Step

None

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-746
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.7.3.1.30 Is handover forced neighbor cell (IsHoForceNcell)


Full Name

Is handover forced neighbor cell

Abbreviation

IsHoForceNcell

3GPP Name

None

3GPP Reference

None
In the case of 1800 M and 900 M network site sharing, it is better to
handover subscribers of 900 M network to 1800 M network. At this time,
force traffic transfer can be conducted.
Force traffic transfer is the last method for on-site traffic adjustment. It
is used in dual-frequency networking. The direction of the forced traffic
transfer is definite, that is, 1800 M sector in the same direction. To avoid
impact on other cells, the force traffic transfer is performed only for a

Description

specific target cell.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

In a 900 M and 1800 M site sharing cell, the 1800 M cell can be set to

Configuration Reason

force traffic transfer cell. In most cases the parameter is set to "No".

Configuration Rule and

This parameter should be set for the target cell in a handover including

Adjustment Suggestion

force traffic transfer.

Change Mode

Offline

Related features

ZGO-02-02-003 Directed-Shift Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->Basic Property

Parameter Modifying
Version

None

5-747
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.7.3.1.31 Is related cell (IsRelatedCell)


Full Name

Is related cell

Abbreviation

IsRelatedCell

3GPP Name

None

3GPP Reference

None
In a uplink rapid fading handover, cells related to the serving cell are preferred as the candidate target cells. If there is no related cell, choose in
the sequence of upper layer same layer lower layer. This is a parameter of an adjacent cell and is used to indicate whether an adjacent cell is

Description

related to the serving cell.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value

If a serving cell has enabled uplink rapid fading handover, the cell can

Configuration Reason

be set as the related cell.

Configuration Rule and

The target cells for uplink rapid fading handover are recommended to be

Adjustment Suggestion

set as related cells.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Handover->Basic Property
Parameter Modifying
Version

None

5-748
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.7.3.2 PS Handover Parameters


5.7.3.2.1 Counter of macro to micro handover (MacroMicroHoN_PS)
Full Name

Counter of macro to micro handover

Abbreviation

MacroMicroHoN_PS

3GPP Name

Internal

3GPP Reference

None
The handover from macro-cell to micro-cell is mainly applied to a two-layer
network. That is, the slowly moving MS hands over from the macro-cell
layer to the micro-cell layer. It judges whether the condition allows the
MS moving slowly performs PS handover to a cell one-layer lower than
the current cell. The condition is the level of adjacent cell exceeds the
threshold for N times. This parameter is to count the adjacent cell level
higher than the threshold when PS handover occurs between the macro

Description

cell and the mico cell.

Managed Object

Neighbor Cell
1..255

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

It is recommended to set the default value to 2, so as to ensure the

Configuration Reason

accuracy and rapidness of handover.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-749
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.2.2 Threshold of macro to micro handover (MacroMicroHoThs_PS)


Full Name

Threshold of macro to micro handover

Abbreviation

MacroMicroHoThs_PS

3GPP Name

Internal

3GPP Reference

None
The handover from macro-cell to micro-cell is mainly applied to a twolayer network. That is, the slowly moving MS hands over from the macrocell layer to the micro-cell layer. It judges whether the condition allows
the MS moving slowly performs PS handover to a cell one-layer lower
than the current cell. The condition is the level of adjacent cell exceeds
the threshold for N times. This parameter is the threshold for cell signal
strength when PS handover occurs between the macro cell and the mico

Description

cell.

Managed Object

Neighbor Cell
0: <-110dBm
1: -110 ~-109 dBm
2: -109 ~ -108dBm
...
61: -50 ~ -49dBm
62: -49~ -48dBm

Value Range and Step

63: > -48dBm

Unit

None

Default Value

20

Default Value

Usually, when other types of handover are not triggered, -90 dBm is

Configuration Reason

enough to initiate macro-micro handver, to balance traffc.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

5-750
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.2.3 Traffic threshold of target cell (TargetTrafficThs_PS)


Full Name

Traffic threshold of target cell

Abbreviation

TargetTrafficThs_PS

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the threshold of the traffic in a target cell. The PS
handover arbitration is made on based on this value. If the traffic of this
target cell is higher than the threshold value, there will be no PS handover

Description

to this cell.

Managed Object

Neighbor Cell
0..100

Value Range and Step

Step: 1

Unit

Default Value

70

Default Value

This parameter can be set to ensure enough resources used for

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None
5-751

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.2.4 Margin of PBGT handover (HoMarginPbgt_PS)


Full Name

Margin of PBGT handover

Abbreviation

HoMarginPbgt_PS

3GPP Name

Internal

3GPP Reference

None
PS handover decision can be made at receiving the related average values. The PBGT_PS value of an adjacent cell is also one of the causes
for PS handover. The decision process is as follows: If the PBGT_PS
value of an adjacent cell is higher than the relevant threshold of this cell,
PS handover should be performed to find a more suitable cell. This parameterr is the threshold that must be used in the PS handover decision

Description

to hand over from an adjacent cell to the local cell through PBGT.

Managed Object

Neighbor Cell
0: -24dB
1: -23dB
2: -22dB
...
46: 22 dB
47: 23dB

Value Range and Step

48: 24dB

Unit

dB

Default Value

30

Default Value

Good signal strength can be ensured when PBGT handover is

Configuration Reason

conducted.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

5-752
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.2.5 Margin of RX handover (HoMarginRxLev_PS)


Full Name

Margin of RX handover

Abbreviation

HoMarginRxLev_PS

3GPP Name

Internal

3GPP Reference

None
PS handover decision can be made at receiving the related average values. In a handover caused by level changes, adjacent cells shall be
screened and sequenced. This parameter is the threshold that must be
used in the handover decision for a PS handover from the adjacent cell

Description

to the local cell through signal strength.

Managed Object

Neighbor Cell
0: -24dB
1: -23dB
2: -22dB
...
46: 22 dB
47: 23dB

Value Range and Step

48: 24dB

Unit

dB

Default Value

30

Default Value

Good signal strength can be ensured when handover caused by signal

Configuration Reason

strength is conducted.

5-753
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.2.6 Margin of quality handover (HoMarginRxQual_PS)


Full Name

Margin of quality handover

Abbreviation

HoMarginRxQual_PS

3GPP Name

Internal

3GPP Reference

None
PS handover decision can be made at receiving the related average values. In handover caused by the quality, adjacent cells shall be screened
and sequenced. This parameter is the threshold that must be used in the
handover decision for a PS handover from the adjacent cell to the local

Description

cell through signal quality.

Managed Object

Neighbor Cell
0: -24dB
1: -23dB
2: -22dB
...
46: 22 dB
47: 23dB

Value Range and Step

48: 24dB

Unit

dB

5-754
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

30

Default Value

Good signal strength can be ensured when handover caused by signal

Configuration Reason

quality is conducted.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.2.7 Minimum RX level (RxLevMin_PS)


Full Name

Minimum RX level

Abbreviation

RxLevMin_PS

3GPP Name

Internal

3GPP Reference

None
This parameter defines the minimum receiving strength level (on PBCCH)
required by MS to handover to this cell. It is one of the parameters to
decide preferred cells during handover control. MS in a serving cell constantly monitors the signal strength on PBCCH of adjacent cells. Adjacent
cells with the receiving intensity level higher than the minimum value de-

Description

fined by this parameter are candidates for handover.

Managed Object

Neighbor Cell

5-755
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0: <-110dBm
1: -110..-109 dBm
2: -109..-108dBm
...
61: -50..-49dBm
62: -49..-48dBm
Value Range and Step

63: > -48dBm

Unit

dB

Default Value

15

Default Value
Configuration Reason

This parameter is relevant to PBCCH. Keep the default setting.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.2.8 Is related cell (IsRelatedCell_PS)


Full Name

Is related cell

Abbreviation

IsRelatedCell_PS

3GPP Name

Internal

3GPP Reference

None
Only the cell related to the serving cell can be a candidate in rapid fading
PS handover. This is a parameter of an adjacent cell and is used to indi-

Description

cate whether an adjacent cell is related to the serving cell.


5-756

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Neighbor Cell
0: Yes

Value Range and Step

1: No

Unit

None

Default Value

Default Value
Configuration Reason

Related to quick handover. Not configured by default.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.2.9 Handover priority (HoPriority_PS)


Full Name

Handover priority

Abbreviation

HoPriority_PS

3GPP Name

Internal

3GPP Reference

None
Cell priorities should be taken into consideration when candidate cells are
sequenced during PS handover. Therefore, there are three decisive factors to sequence candidate cells: priority, traffic, and radio communication
environment. Priority and traffic have the most impact on cell sequencing.
If they lead to the same result, sequence cells by radio conditions. The

Description

priority of a cell becomes higher with the increasing of this value.

5-757
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Neighbor Cell
0..7 (0 means the lowest priority)

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The priority gets the middle value by default.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.3.2.10 Max TX power of MS (MsTxPwrMax_PS)


Full Name

Max TX power of MS

Abbreviation

MsTxPwrMax_PS

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the highest power allowed by MS in an adjacent

Description

cell when on PBCCH.

Managed Object

Neighbor Cell
0..31

Value Range and Step

Step: 1

Unit

dBm
5-758

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

Default Value
Configuration Reason

This parameter is relevant to PBCCH. Keep the default setting.

Configuration Rule and

This parameter is relevant to PBCCH, and is not recommended to be

Adjustment Suggestion

used.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Handover->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.4 Adjacent Cell Reselection Parameters


5.7.4.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None

Description

This parameter means the site ID. It cannot be modified.


Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None

Default Value

5-759
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell Rese-

OMC Access Path


Parameter

Modifying

Version
Parameter

lection

None
Modifying

Detail

None

5.7.4.2 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell

5-760
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell Rese-

OMC Access Path


Parameter

Modifying

Version
Parameter
Detail

lection

None
Modifying
None

5-761
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.7.4.3 Adjacent cell reselection object ID (ReSelObjectId)


Full Name

Adjacent cell reselection object ID

Abbreviation

ReSelObjectId

3GPP Name

None

3GPP Reference

None
This parameter is a unique identification of adjacent cell reselection ob-

Description

ject.

Managed Object

Cell
1..64

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

1: the initial value

Configuration Rule and


Adjustment Suggestion

Depends on the actual configuration.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.4.4 Adjacent cell report priority (RepPrioPS)


Full Name

Adjacent cell report priority

5-762
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Abbreviation

RepPrioPS

3GPP Name

REP_PRIORITY

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the priorities of the measurement reports from
adjacent cells. The parameter information is broadcast to an MS through
SI2quater messages. This parameter indicates the priorities of the
measurement reports from adjacent cells.
The adjacent cell reporting is performed according to the following
priorities:
Adjacent cells with the same frequency band must have the following
features: BSIC of color code is valid; Its measured field intensity ranks
high among cells in the same frequency band and is larger than or equal
to the lower limit specified by RprtThoPSXXX. Here, XXX represents the
frequency band of a serving cell.
Adjacent cell in the frequency band different from that of the serving
cell must have the following features: BSIC of color code is valid.
Its measured field intensity ranks high among cells in the same
frequency band and is larger than or equal to the lower limit specified
by RprtThoPSXXX. Here, XXX represents the frequency band different
from that of serving cell.
Adjacent cells using other access technologies like UTRAN/FDD must
have the following features: The scrambling code of the cell is correct.
Its measured field intensity ranks high among cells with the same access
technologies and is larger than or equal to the lower limit specified
by XXXRprtThoPS. Here, XXX represents access technologies like
WCDMA/FDD.
For the priorities mentioned above, if there is vacancies for the cells with
the current priority, leave the vacancies to the adjacent cells with the next
priority. For the access technologies such as UTRAN/FDD, or frequency
band such as GSM 900 or RepPrioPS, cells with higher frequency bands
are preferred. For cells with same RepPrioPS, the cell with greater
sum of RprtThoPSXXX (or XXXRprtThoPS) and RprtOffsetPSXXX (or

Description

XXXRprtOffsetPS) is preferred.

Managed Object

Cell

Value Range and Step

(Low, High)

Unit

None

Default Value

Low

Default Value
Configuration Reason

Refer to the CS parameter.

5-763
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

For the last priority setting of the measurement report from adjacent
cells, if the cells with higher priorities are expected to report, RepPrioPS
Configuration Rule and
Adjustment Suggestion

for an adjacent cell should be set high. Then the measurement results
will be reported every time. In most cases every adjacent cell is treated
the same. Cells with low priorities does not report frequently (when
ReportRatePS is set to 1), RepPrioPS is recommended to be set with
the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.4.5 CCN support (CCNSupport)


Full Name

CCN support

Abbreviation

CCNSupport

3GPP Name

CCN_ACTIVE

3GPP Reference

3GPP TS44.060 V5.19.0

5-764
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

The CCN_ACTIVE parameter is used in GPRS Cell Options IE of SI13


on BCCH at the network side, to indicate whether CCN mode is applied
when a reselection is conducted from the current cell to a GSM adjacent
cell. If GPRS Cell Options IE does not include the CCN_ACTIVE
parameter, or the CCN_ACTIVE parameter is not set to "enabled", MS
will not use CCN mode. If the CCN_ACTIVE parameter is enabled and
the cell reselection will be performed to a GSM cell, check that the
CCN_SUPPORTED exists in an adjacent cell;
If the CCN_SUPPORTED does not exist, MS can use CCN mode;
If the CCN_SUPPORTED exists and it is set to "disabled", MS cannot
use CCN mode;
If the CCN_SUPPORTED exists and it is set to "enabled", MS can use
CCN mode;
The network side can indicate whether the CCN_ACTIVE parameter
is enabled for a particular MS through Packet Measurement Order
messages. It can also indicate whether the CCN_ACTIVE parameter
is enabled for a particular MS target cell through Packet Cell Change
Order or PS Handover Command messages. CCN_ACTIVE on PACCH
setting takes higher priority than the system message broadcast setting.
Description

An MS will use CCN mode under NC0 and NC1 modes.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.


If the CCN Active function is enabled and the parameter of the adjacent
cell is set to "Yes", CCN mode is used during the reselection to this

Configuration Rule and

cell; if the parameter is set to "No", CCN mode will not be used during

Adjustment Suggestion

the reselection. In most cases, CCN Active should be set to enable


this function and the CCN Support function should be enabled in the
adjacent cell.

Change Mode

Offline

Related features

ZGO-02-02-010 Network-assisted Cell Change

Related Parameters

[BSC]NACCSupport
[Cell]CCNActive
[Cell]SIStatusInd

Relationship
Related Interfaces

If NACC function is enabled, CCNActive/SIStatusInd/CCNSupport must


be enabled at the same time.
Um

5-765
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.4.6 Related Cell DN (RelationDN)


Full Name

Related Cell DN

Abbreviation

RelationDN

3GPP Name

None

3GPP Reference

None
A user can click <Select> to select cell or external cell in displayed interface, check <mutual configuration>, you can mutually configure it as

Description

reselection and handover cell.

Managed Object

Cell

Value Range and Step

None

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

Fixed, No modification

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

5-766
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->Adjacent Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.5 UTRAN Adjacent Cell Handover and Reselection Parameters


5.7.5.1 Basic Property
5.7.5.1.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None

Description

This parameter means the site ID. It cannot be modified.


Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

5-767
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent

OMC Access Path


Parameter

Modifying

Version
Parameter

Cell Handover and Reselection->Basic Property

None
Modifying

Detail

None

5.7.5.1.2 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell
1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None
5-768

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent

OMC Access Path


Parameter

Modifying

Version
Parameter

Cell Handover and Reselection->Basic Property

None
Modifying

Detail

None

5.7.5.1.3 User Label


Full Name

User Label

Abbreviation

UserLabel

3GPP Name

None

3GPP Reference

None

Description
Managed Object
Value Range and
Step

This parameter means the UTRAN cell handover and reselection name for
users to identify.
Cell
Character string with the maximum length of 40

Unit

None

Default Value

None

Default Value
Configuration
Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

5-769
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent Cell

OMC Access Path

Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.5.1.4 Ec/No offset handover to UTRAN adjacent cell (HoEcNoOffset3G)


Full Name

Ec/No offset handover to UTRAN adjacent cell

Abbreviation

HoEcNoOffset3G

3GPP Name

FDD_Qmin_Offset

3GPP Reference

3GPP TS 45.008
After a handover from GSM to UTRAN is triggered, the UTRAN adjacent
cell meets the minimum requirement for normal UE communication.
This parameter is a prerequisite to ensure enough field intensity for
uplink/downlink of UTRAN adjacent cells. It also controls the priority of a

Description

UE to handover to different adjacent cells.

Managed Object

Cell
0..49

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

This parameter should be set according to the radio environment of the

Configuration Reason

border area of 2/3G.


If this parameter is set too low, it is easy to trigger a handover to a 3G

Configuration Rule and


Adjustment Suggestion

adjacent cell;
If this parameter is set too high, it is difficult to trigger a handover to
a 3G adjacent cell.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

[Cell]FDDRepQntCS

Relationship

This parameter takes effect only when FDDRepQntCS is 1;


5-770

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.5.1.5 RSCP offset handover to UTRAN adjacent cell (HoRSCPOffset3G)


Full Name

RSCP offset handover to UTRAN adjacent cell

Abbreviation

HoRSCPOffset3G

3GPP Name

TDD_Qoffset, FDD_Qoffset

3GPP Reference

3GPP TS 45.008
After a handover from GSM to UTRAN is triggered, the UTRAN adjacent
cell meets the minimum requirement for normal UE communication.
This parameter is a prerequisite to ensure enough field intensity for
uplink/downlink of UTRAN adjacent cells. It also controls the priority of a

Description

UE to handover to different adjacent cells.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

This parameter should be set according to the radio environment of the

Configuration Reason

border area of 2/3G.


If this parameter is set too low, it is easy to trigger a handover to a 3G

Configuration Rule and


Adjustment Suggestion

adjacent cell;
If this parameter is set too high, it is difficult to trigger a handover to
a 3G adjacent cell.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

[Cell]FDDRepQntCS

Relationship

This parameter takes effect only when FDDRepQntCS is 0;


5-771

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.5.1.6 Target cell traffic threshold (TargetCellTrafficThs)


Full Name

Target cell traffic threshold

Abbreviation

TargetCellTrafficThs

3GPP Name

None

3GPP Reference

None
This parameter indicates the threshold of the traffic in a target cell.
The PS handover decision is made based on this value. If the traffic
of this target cell is higher than the threshold value, there will be no
PS handover to this cell.

Description

This parameter is used in handover to UTRAN adjacent cell.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

75

Default Value

The resources should be obtained and at the same time the congestion

Configuration Reason

in target cell should be avoided.

Configuration Rule and

If the parameter is set too high, congestion will be likely to happen in

Adjustment Suggestion

the target cell.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

5-772
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.5.1.7 Adjacent UTRAN cell handover and reselection object ID (S3GHoRSObjectId)


Full Name

Adjacent UTRAN cell handover and reselection object ID

Abbreviation

S3GHoRSObjectId

3GPP Name

None

3GPP Reference

None
This parameter is a unique identification of UTRAN adjacent cell handover

Description

and reselection object.

Managed Object

Cell
1..64

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-773
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.5.1.8 CS priority of adjacent cell reported in measure report (RepPrioCS)


Full Name

CS priority of adjacent cell reported in measure report

Abbreviation

RepPrioCS

3GPP Name

None

3GPP Reference

None
The adjacent cell reporting is performed according to the following
priorities:
Adjacent cells with the same frequency band must have the following
features: BSIC of color code is valid; Its measured field intensity ranks
high among cells in the same frequency band and is larger than or equal
to the lower limit specified by RprtThoCSXXX. Here, XXX represents the
frequency band of a serving cell.
Adjacent cell in the frequency band different from that of the serving
cell must have the following features: BSIC of color code is valid.
Its measured field intensity ranks high among cells in the same
frequency band and is larger than or equal to the lower limit specified
by RprtThoCSXXX. Here, XXX represents the frequency band different
from that of serving cell.
Adjacent cells using other access technologies like UTRAN/FDD must
have the following features: The scrambling code of the cell is correct.
Its measured field intensity ranks high among cells with the same access
technologies and is larger than or equal to the lower limit specified
by XXXRprtThoCS. Here, XXX represents access technologies like
WCDMA/FDD.
For the priorities mentioned above, if there are vacancies for the cells
with the current priority, leave the vacancies to the adjacent cells with
the next priority. For the access technologies such as UTRAN/FDD, or
frequency band such as GSM 900 M or RepPrioCS, cells with higher
frequency bands are preferred. For cells with the same RepPrioCS,
the cell with greater sum of RprtThoCSXXX (or XXXRprtThoCS) and

Description

RprtOffsetCSXXX (or XXXRprtOffsetCS) is preferred.

Managed Object

Cell

Value Range and Step

Low, High

5-774
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

None

Default Value

Low

Default Value
Configuration Reason

This parameter is set low by default.

Configuration Rule and


Adjustment Suggestion

No modification after configuration if there is no special demands.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.5.1.9 PS priority of adjacent cells reported in measurement report (RepPrioPS)


Full Name

PS priority of adjacent cells reported in measurement report

Abbreviation

RepPrioPS

3GPP Name

REP_PRIORITY

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the priorities of the measurement reports from
adjacent cells. The parameter information is broadcast to an MS through
SI2quater, PSI3ter and PSI3quater messages. This parameter indicates
the priorities of the measurement reports from adjacent cells.
The adjacent cell reporting is performed according to the following
priorities:
Adjacent cells with the same frequency band must have the following
features: BSIC of color code is valid; Its measured field intensity ranks
high among cells in the same frequency band and is larger than or equal
to the lower limit specified by RprtThoPSXXX. Here, XXX represents the

Description

frequency band of a serving cell.


5-775

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Adjacent cell in the frequency band different from that of the serving
cell must have the following features: BSIC of color code is valid.
Its measured field intensity ranks high among cells in the same
frequency band and is larger than or equal to the lower limit specified
by RprtThoPSXXX. Here, XXX represents the frequency band different
from that of serving cell.
Adjacent cells using other access technologies like UTRAN/FDD must
have the following features: The scrambling code of the cell is correct.
Its measured field intensity ranks high among cells with the same access
technologies and is larger than or equal to the lower limit specified
by XXXRprtThoPS. Here, XXX represents access technologies like
WCDMA/FDD.
For the priorities mentioned above, if there are vacancies for the cells
with the current priority, leave the vacancies to the adjacent cells with
the next priority.
Managed Object

Cell

Value Range and Step

(Low, High)

Unit

None

Default Value

Low

Default Value
Configuration Reason

Recommended value from the protocol


For the last priority setting of the measurement report from adjacent
cells, if the cells with higher priorities are expected to report, RepPrioPS

Configuration Rule and


Adjustment Suggestion

for an adjacent cell should be set high. Then the measurement results
will be reported every time. In most cases every adjacent cell is treated
the same. Cells with low priorities does not report frequently (when
ReportRatePS is set to 1), RepPrioPS is recommended to be set with
the default value.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]ReportRatePS
The parameter RepPrioPS configures every adjacent cell; the parameter

Relationship

RepRatePS configures the current cell. The two parameters determines


the measurement report hand-in frequency in the adjacent cell.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-776
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.5.1.10 CCN support (CCNSupport)


Full Name

CCN support

Abbreviation

CCNSupport

3GPP Name

CCN_ACTIVE

3GPP Reference

3GPP TS44.060 V5.19.0


The CCN_ACTIVE parameter is used in GPRS Cell Options IE of SI13
on BCCH at the network side, to indicate whether CCN mode is applied
when a reselection is conducted from the current cell to a GSM adjacent
cell. If GPRS Cell Options IE does not include the CCN_ACTIVE
parameter, or the CCN_ACTIVE parameter is not set to "enabled", MS
will not use CCN mode. If the CCN_ACTIVE parameter is enabled and
the cell reselection will be performed to a GSM cell, check that the
CCN_SUPPORTED exists in an adjacent cell;
If the CCN_SUPPORTED does not exist, MS can use CCN mode;
If the CCN_SUPPORTED exists and it is set to "disabled", MS cannot
use CCN mode;
If the CCN_SUPPORTED exists and it is set to "enabled", MS can use
CCN mode;
The network side can indicate whether the CCN_ACTIVE parameter
is enabled for a particular MS through Packet Measurement Order
messages. It can also indicate whether the CCN_ACTIVE parameter
is enabled for a particular MS target cell through Packet Cell Change
Order or PS Handover Command messages. CCN_ACTIVE on PACCH
setting takes higher priority than the system message broadcast setting.

Description

An MS will use CCN mode under NC0 and NC1 modes.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.

5-777
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If the CCN Active function is enabled and the parameter of the adjacent
cell is set to "Yes", CCN mode is used during the reselection to this
Configuration Rule and
Adjustment Suggestion

cell; if the parameter is set to "No", CCN mode will not be used during
the reselection. In most cases, CCN Active should be set to enable
this function and the CCN Support function should be enabled in the
adjacent cell.

Change Mode

Offline

Related features

ZGO-02-02-010 Network-assisted Cell Change

Related Parameters

[BSC]NACCSupport
[Cell]CCNActive
[Cell]SIStatusInd

Relationship

If NACC function is enabled, CCNActive/SIStatusInd/CCNSupport must


be enabled at the same time.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.5.1.11 Is the directed retry ncell (IsDirectRetryCell)


Full Name

Is the directed retry ncell

Abbreviation

IsDirectRetryCell

3GPP Name

Null

3GPP Reference

Null
The parameter is used to indicate whether the neighbor cell is the directed

Description

retry cell. The parameter is one of the neighbor cell parameters.

Managed Object

External Neighbor Cell


0: No

Value Range and Step

1: Yes

Unit

Null

Default Value

Yes

5-778
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

All the adjacent cell could be the directed retry ncell, so the default value

Configuration Reason

is Yes.

Configuration Rule and

If the network planning requires the cell to be a directed retry cell, set the

Adjustment Suggestion

parameter to "Yes".

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set

OMC Access Path

ID->BSC Function ID->Site config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover and Reselection

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

5.7.5.1.12 Related Cell DN (RelationDN)


Full Name

Related Cell DN

Abbreviation

RelationDN

3GPP Name

None

3GPP Reference

None
A user can click <Select> to select cell or external cell in displayed interface, check <mutual configuration>, you can mutually configure it as

Description

reselection and handover cell.

Managed Object

Cell

Value Range and Step

None

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

Fixed, No modification

5-779
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Cell Handover and Reselection->Basic Property
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.5.1.13 The priority of Utran Cell (UtranCellPrio)


Full Name

The priority of Utran Cell

Abbreviation

UtranCellPrio

3GPP Name

UTRAN_PRIORITY

3GPP Reference

3GPP TS 44018 V8.9.0

Description

This parameter determines the priority of an adjacent UTRAN cell.

Managed Object

Cell

Value Range and Step

0-7; 0 = lowest priority, .., 7 = highest priority

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The value of this parameter is the same as that of UtranDefaultPrio.


To make an MS be reselected to this adjacent cell with high priority,
configure this parameter to a large value. Otherwise, configure this
parameter to a small value.

Change Mode

Offline

Related features

None

Related Parameters

PrioReselSupport, ServCellPrio, UtranDefaultPrio

5-780
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

When the PrioReselSupport switch is enabled, the value of UtranCellPrio


Relationship

cannot be the same as that of ServCellPrio, and the default value equals
to that of UtranDefaultPrio.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover and Reselection->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.5.2 PS Handover Parameters


5.7.5.2.1 Target cell traffic threshold (TargetCellTraThs_PS)
Full Name

Target cell traffic threshold

Abbreviation

TargetCellTraThs_PS

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the service traffic threshold for 3G target cells
when 3G PS handover is being conducted. The PS handover arbitration
is made on based on this value. If the traffic of this target cell is higher

Description

than the threshold value, there will be no PS handover to this cell.

Managed Object

External Neighbor Cell


0..100

Value Range and Step

Step: 1

Unit

Default Value

70

Default Value

This parameter can be set to ensure enough resources used for

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover
5-781

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Cell Handover and Reselection->PSHOC Parameter
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.5.2.2 EcNo offset (HoEcNoOffset3G_PS)


Full Name

EcNo offset

Abbreviation

HoEcNoOffset3G_PS

3GPP Name

Internal

3GPP Reference

None
After a handover from GSM to UTRAN is triggered, the UTRAN adjacent cell meets the minimum requirement for normal UE communication.
This parameter is a prerequisite to ensure enough field intensity for uplink/downlink of UTRAN adjacent cells. It also controls the priority of a UE
to handover to different adjacent cells. This parameter is a must for 2/3G

Description

PS handover.

Managed Object

External Neighbor Cell


0..49

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

This parameter should be set according to the radio environment of the

Configuration Reason

border area of 2/3G.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

5-782
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover and Reselection->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.5.2.3 RSCP offset (HoRSCPOffset3G_PS)


Full Name

RSCP offset

Abbreviation

HoRSCPOffset3G_PS

3GPP Name

Internal

3GPP Reference

None
After a handover from GSM to UTRAN is triggered, the UTRAN adjacent cell meets the minimum requirement for normal UE communication.
This parameter is a prerequisite to ensure enough field intensity for uplink/downlink of UTRAN adjacent cells. It also controls the priority of a UE
to handover to different adjacent cells. This parameter is a must for 2/3G

Description

PS handover.

Managed Object

External Neighbor Cell


0..63

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

This parameter should be set according to the radio environment of the

Configuration Reason

border area of 2/3G.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

5-783
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Cell Handover and Reselection->PSHOC Parameter
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.6 UTRAN Adjacent Cell Handover Parameters


5.7.6.1 Basic Property
5.7.6.1.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None

Description

This parameter means the site ID. It cannot be modified.


Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

5-784
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent

OMC Access Path


Parameter

Modifying

Version
Parameter

Cell Handover Parameters->Basic Property

None
Modifying

Detail

None

5.7.6.1.2 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell
1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

5-785
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent

OMC Access Path


Parameter

Modifying

Version
Parameter

Cell Handover Parameters->Basic Property

None
Modifying

Detail

None

5.7.6.1.3 Ec/No offset handover (HoEcNoOffset3G)


Full Name

Ec/No offset handover

Abbreviation

HoEcNoOffset3G

3GPP Name

FDD_Qmin_Offset

3GPP Reference

3GPP TS 45.008
After a handover from GSM to UTRAN is triggered, the UTRAN adjacent
cell meets the minimum requirement for normal UE communication.
This parameter is a prerequisite to ensure enough field intensity for
uplink/downlink of UTRAN adjacent cells. It also controls the priority of a

Description

UE to handover to different adjacent cells.

Managed Object

Cell
0..49

Value Range and Step

Step: 1

Unit

None

Default Value

5-786
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

This parameter should be set according to the radio environment of the

Configuration Reason

border area of 2/3G.


If this parameter is set too low, it is easy to trigger a handover to a 3G

Configuration Rule and


Adjustment Suggestion

adjacent cell;
If this parameter is set too high, it is difficult to trigger a handover to
a 3G adjacent cell.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

[Cell]FDDRepQntCS

Relationship

This parameter takes effect only when FDDRepQntCS is 1;

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover Parameters->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.6.1.4 Target cell traffic threshold (TargetCellTrafficThs)


Full Name

Target cell traffic threshold

Abbreviation

TargetCellTrafficThs

3GPP Name

None

3GPP Reference

None
This parameter indicates the threshold of the traffic in a target cell.
The PS handover decision is made based on this value. If the traffic
of this target cell is higher than the threshold value, there will be no
PS handover to this cell.

Description

This parameter is used in handover to UTRAN adjacent cell.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

None

Default Value

75
5-787

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

The resources should be obtained and at the same time the congestion

Configuration Reason

in target cell should be avoided.

Configuration Rule and

If the parameter is set too high, congestion will be likely to happen in

Adjustment Suggestion

the target cell.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover Parameters->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.6.1.5 RSCP offset handover (HoRSCPOffset3G)


Full Name

RSCP offset handover

Abbreviation

HoRSCPOffset3G

3GPP Name

TDD_Qoffset, FDD_Qoffset

3GPP Reference

3GPP TS 45.008
After a handover from GSM to UTRAN is triggered, the UTRAN adjacent
cell meets the minimum requirement for normal UE communication.
This parameter is a prerequisite to ensure enough field intensity for
uplink/downlink of UTRAN adjacent cells. It also controls the priority of a

Description

UE to handover to different adjacent cells.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

5-788
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value

This parameter should be set according to the radio environment of the

Configuration Reason

border area of 2/3G.


If this parameter is set too low, it is easy to trigger a handover to a 3G

Configuration Rule and


Adjustment Suggestion

adjacent cell;
If this parameter is set too high, it is difficult to trigger a handover to
a 3G adjacent cell.

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

[Cell]FDDRepQntCS

Relationship

This parameter takes effect only when FDDRepQntCS is 0;

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover Parameters->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.6.1.6 Adjacent UTRAN cell handover object (S3GHoObjectId)


Full Name

Adjacent UTRAN cell handover object

Abbreviation

S3GHoObjectId

3GPP Name

None

3GPP Reference

None
This parameter is a unique identification of UTRAN adjacent cell handover

Description

object.

Managed Object

Cell
1..64

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

5-789
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover Parameters->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.6.1.7 CS adjacent cell report priority (RepPrioCS)


Full Name

CS adjacent cell report priority

Abbreviation

RepPrioCS

3GPP Name

REP_PRIORITY

3GPP Reference

3GPP TS 45.008 V5.22.0


This parameter defines the priority of adjacent cells to report the
measurement results. The adjacent cell reporting is performed according
to the following priorities:
Adjacent cell in the same frequency band as the serving cell must have
the following features:
BSIC of color code is valid;
Its measured field intensity ranks high among cells in the same frequency
band (actual band place depends on SERVING_BAND_REPORTING)
and is larger than or equal to the lower limit specified by RprtThoCSXXX.
Here, XXX represents frequency band of serving cell.
Adjacent cell in the frequency band different from that of the serving cell
must have the following features: have the following features:
BSIC of color code is valid;
Its measured field intensity ranks high among cells in the same frequency

Description

band (actual band place depends on MULTIBAND_REPORTING) and is

5-790
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

larger than or equal to the lower limit specified by RprtThoCSXXX. Here,


XXX represents frequency band of serving cell.
Adjacent cells using other access technologies like WCDMA/FDD must
have the following features: These cells have the following features:
The cell scrambling codes are correct.
Its measured field intensity should rank high among cells with
the same access technologies (actual band place depends on
XXX_MULTIRAT_REPORTING) and is larger than or equal to the
lower limit specified by XXXRprtThoCS. Here, XXX represents access
technologies like WCDMA/FDD.
For GSM adjacent cell with valid BSIC, or GSM adjacent cell with
permitted NCC but invalid BCC, or adjacent cell with other access
technologies, if RepPrioCS and REPORTING_RATE of these cells are
low, the reporting frequency is also low.
Notes:
If the current priority has vacancies, leave them to adjacent cells of the
next priority;
For access technology such as WCDMA/FDD, or frequency band such
as GSM 900 M, the cell with higher RepPrioCS is preferred.
For cells with the same RepPrioCS, the cell with greater sum of
RprtThoCSXXX (or XXXRprtThoCS) and RprtOffsetCSXXX (or
XXXRprtOffsetCS) is preferred.
Managed Object

Cell

Value Range and Step

Low, High

Unit

None

Default Value

Low

Default Value
Configuration Reason

This parameter is set low by default.

Configuration Rule and


Adjustment Suggestion

No modification after configuration if there is no special demands.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-791
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover Parameters->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.6.1.8 Is the directed retry ncell (IsDirectRetryCell)


Full Name

Is the directed retry ncell

Abbreviation

IsDirectRetryCell

3GPP Name

Null

3GPP Reference

Null
The parameter is used to indicate whether the neighbor cell is the directed

Description

retry cell. The parameter is one of the neighbor cell parameters.

Managed Object

External Neighbor Cell


0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value

All the adjacent cell could be the directed retry ncell, so the default value

Configuration Reason

is Yes.

Configuration Rule and

If the network planning requires the cell to be a directed retry cell, set the

Adjustment Suggestion

parameter to "Yes".

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover Parameters->Basic Property

Parameter Modifying
Version

iBSCV6.20.711a
5-792

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

New

5.7.6.1.9 Related Cell DN (RelationDN)


Full Name

Related Cell DN

Abbreviation

RelationDN

3GPP Name

None

3GPP Reference

None
A user can click <Select> to select cell or external cell in displayed interface, check <mutual configuration>, you can mutually configure it as

Description

reselection and handover cell.

Managed Object

Cell

Value Range and Step

None

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

Fixed, No modification

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover Parameters->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-793
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.7.6.2 PS Handover Parameters


5.7.6.2.1 Target cell traffic threshold (TargetCellTraThs_PS)
Full Name

Target cell traffic threshold

Abbreviation

TargetCellTraThs_PS

3GPP Name

Internal

3GPP Reference

None
This parameter indicates the service traffic threshold for 3G target cells
when 3G PS handover is being conducted. The PS handover arbitration
is made on based on this value. If the traffic of this target cell is higher

Description

than the threshold value, there will be no PS handover to this cell.

Managed Object

External Neighbor Cell


0..100

Value Range and Step

Step: 1

Unit

Default Value

70

Default Value

This parameter can be set to ensure enough resources used for

Configuration Reason

handover.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-794
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.7.6.2.2 EcNo offset (HoEcNoOffset3G_PS)


Full Name

EcNo offset

Abbreviation

HoEcNoOffset3G_PS

3GPP Name

Internal

3GPP Reference

None
After a handover from GSM to UTRAN is triggered, the UTRAN adjacent cell meets the minimum requirement for normal UE communication.
This parameter is a prerequisite to ensure enough field intensity for uplink/downlink of UTRAN adjacent cells. It also controls the priority of a UE
to handover to different adjacent cells. This parameter is a must for 2/3G

Description

PS handover.

Managed Object

External Neighbor Cell


0..49

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

This parameter should be set according to the radio environment of the

Configuration Reason

border area of 2/3G.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-795
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.7.6.2.3 RSCP offset (HoRSCPOffset3G_PS)


Full Name

RSCP offset

Abbreviation

HoRSCPOffset3G_PS

3GPP Name

Internal

3GPP Reference

None
After a handover from GSM to UTRAN is triggered, the UTRAN adjacent cell meets the minimum requirement for normal UE communication.
This parameter is a prerequisite to ensure enough field intensity for uplink/downlink of UTRAN adjacent cells. It also controls the priority of a UE
to handover to different adjacent cells. This parameter is a must for 2/3G

Description

PS handover.

Managed Object

External Neighbor Cell


0..63

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

This parameter should be set according to the radio environment of the

Configuration Reason

border area of 2/3G.

Configuration Rule and


Adjustment Suggestion

No need to modify. This function is not enabled in this version.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Handover->PSHOC Parameter

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-796
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.7.7 UTRAN Adjacent Cell Reselection Parameters


5.7.7.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None
This parameter means the site ID. It cannot be modified.

Description

Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent

OMC Access Path


Parameter

Modifying

Version
Parameter
Detail

Cell Reselection

None
Modifying
None

5.7.7.2 BTS ID (BtsId)


Full Name

BTS ID
5-797

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell
1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent

OMC Access Path

Cell Reselection

5-798
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter

Modifying

Version
Parameter

None
Modifying

Detail

None

5.7.7.3 Adjacent UTRAN cell reselection object ID (S3GrsObjectId)


Full Name

Adjacent UTRAN cell reselection object ID

Abbreviation

S3GrsObjectId

3GPP Name

None

3GPP Reference

None
This parameter is a unique identification of UTRAN adjacent cell reselec-

Description

tion object.

Managed Object

Cell
1..64

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

ZGO-02-03-002 GSM/WCDMA Interworking Phase I

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Reselection

Parameter Modifying
Version

None

5-799
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.7.7.4 Adjacent cell report priority (RepPrioPS)


Full Name

Adjacent cell report priority

Abbreviation

RepPrioPS

3GPP Name

REP_PRIORITY

3GPP Reference

3GPP TS 45.008 V6.19.0


This parameter indicates the priorities of the measurement reports from
adjacent cells. The parameter information is broadcast to an MS through
SI2quater messages. This parameter indicates the priorities of the
measurement reports from adjacent cells.
The adjacent cell reporting is performed according to the following
priorities:
Adjacent cells with the same frequency band must have the following
features: BSIC of color code is valid; Its measured field intensity ranks
high among cells in the same frequency band and is larger than or equal
to the lower limit specified by RprtThoPSXXX. Here, XXX represents the
frequency band of a serving cell.
Adjacent cell in the frequency band different from that of the serving
cell must have the following features: BSIC of color code is valid.
Its measured field intensity ranks high among cells in the same
frequency band and is larger than or equal to the lower limit specified
by RprtThoPSXXX. Here, XXX represents the frequency band different
from that of serving cell.
Adjacent cells using other access technologies like UTRAN/FDD must
have the following features: The scrambling code of the cell is correct.
Its measured field intensity ranks high among cells with the same access
technologies and is larger than or equal to the lower limit specified
by XXXRprtThoPS. Here, XXX represents access technologies like
WCDMA/FDD.
For the priorities mentioned above, if there is vacancies for the cells with
the current priority, leave the vacancies to the adjacent cells with the next
priority. For the access technologies such as UTRAN/FDD, or frequency
band such as GSM 900 or RepPrioPS, cells with higher frequency bands
are preferred. For cells with same RepPrioPS, the cell with greater
sum of RprtThoPSXXX (or XXXRprtThoPS) and RprtOffsetPSXXX (or

Description

XXXRprtOffsetPS) is preferred.

Managed Object

Cell

Value Range and Step

(Low, High)

5-800
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Unit

None

Default Value

Low

Default Value
Configuration Reason

Refer to the CS parameter.


For the last priority setting of the measurement report from adjacent
cells, if the cells with higher priorities are expected to report, RepPrioPS

Configuration Rule and


Adjustment Suggestion

for an adjacent cell should be set high. Then the measurement results
will be reported every time. In most cases every adjacent cell is treated
the same. Cells with low priorities does not report frequently (when
ReportRatePS is set to 1), RepPrioPS is recommended to be set with
the default value.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.7.5 CCN support (CCNSupport)


Full Name

CCN support

Abbreviation

CCNSupport

3GPP Name

CCN_ACTIVE

3GPP Reference

3GPP TS44.060 V5.19.0

5-801
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The CCN_ACTIVE parameter is used in GPRS Cell Options IE of SI13


on BCCH at the network side, to indicate whether CCN mode is applied
when a reselection is conducted from the current cell to a GSM adjacent
cell. If GPRS Cell Options IE does not include the CCN_ACTIVE
parameter, or the CCN_ACTIVE parameter is not set to "enabled", MS
will not use CCN mode. If the CCN_ACTIVE parameter is enabled and
the cell reselection will be performed to a GSM cell, check that the
CCN_SUPPORTED exists in an adjacent cell;
If the CCN_SUPPORTED does not exist, MS can use CCN mode;
If the CCN_SUPPORTED exists and it is set to "disabled", MS cannot
use CCN mode;
If the CCN_SUPPORTED exists and it is set to "enabled", MS can use
CCN mode;
The network side can indicate whether the CCN_ACTIVE parameter
is enabled for a particular MS through Packet Measurement Order
messages. It can also indicate whether the CCN_ACTIVE parameter
is enabled for a particular MS target cell through Packet Cell Change
Order or PS Handover Command messages. CCN_ACTIVE on PACCH
setting takes higher priority than the system message broadcast setting.
Description

An MS will use CCN mode under NC0 and NC1 modes.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a switch for a special function. The switch is disabled by default.


If the CCN Active function is enabled and the parameter of the adjacent
cell is set to "Yes", CCN mode is used during the reselection to this

Configuration Rule and

cell; if the parameter is set to "No", CCN mode will not be used during

Adjustment Suggestion

the reselection. In most cases, CCN Active should be set to enable


this function and the CCN Support function should be enabled in the
adjacent cell.

Change Mode

Offline

Related features

ZGO-02-02-010 Network-assisted Cell Change

Related Parameters

[BSC]NACCSupport
[Cell]CCNActive
[Cell]SIStatusInd

Relationship
Related Interfaces

If NACC function is enabled, CCNActive/SIStatusInd/CCNSupport must


be enabled at the same time.
Um

5-802
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.7.6 Related Cell DN (RelationDN)


Full Name

Related Cell DN

Abbreviation

RelationDN

3GPP Name

None

3GPP Reference

None
A user can click <Select> to select cell or external cell in displayed interface, check <mutual configuration>, you can mutually configure it as

Description

reselection and handover cell.

Managed Object

Cell

Value Range and Step

None

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

Fixed, No modification

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

5-803
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.7.7.7 The priority of Utran Cell (UtranCellPrio)


Full Name

The priority of Utran Cell

Abbreviation

UtranCellPrio

3GPP Name

UTRAN_PRIORITY

3GPP Reference

3GPP TS 44018 V8.9.0

Description

This parameter determines the priority of an adjacent UTRAN cell.

Managed Object

Cell

Value Range and Step

0-7; 0 = lowest priority, .., 7 = highest priority

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The value of this parameter is the same as that of UtranDefaultPrio.


To make an MS be reselected to this adjacent cell with high priority,
configure this parameter to a large value. Otherwise, configure this
parameter to a small value.

Change Mode

Offline

Related features

None

Related Parameters

PrioReselSupport, ServCellPrio, UtranDefaultPrio


When the PrioReselSupport switch is enabled, the value of UtranCellPrio

Relationship

cannot be the same as that of ServCellPrio, and the default value equals
to that of UtranDefaultPrio.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-804
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->UTRAN Adjacent


Cell Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.8 Frequency Hopping System Parameters


5.8.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None

Description

This parameter means the site ID. It cannot be modified.


Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO

5-805
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Frequency Hopping
OMC Access Path
Parameter

Modifying

Version
Parameter

System

None
Modifying

Detail

None

5.8.2 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell
1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None
5-806

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->Frequency Hopping

OMC Access Path


Parameter

Modifying

Version
Parameter

System

None
Modifying

Detail

None

5.8.3 Frequency hopping ID (FhsId)


Full Name

Frequency hopping ID

Abbreviation

FhsId

3GPP Name

None

3GPP Reference

None

Description

This parameter is an identification of frequency hopping system.

Managed Object

Cell

Value Range and Step

1..255

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

None

Relationship

None

Related Interfaces

None

ZGO-04-03-001 Synthesized Frequency Hopping

5-807
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Frequency


Hopping System

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.8.4 Hopping sequence No. (HSN)


Full Name

Hopping sequence No.

Abbreviation

HSN

3GPP Name

hopping sequence number

3GPP Reference

3GPP TS 44.018
According to GSM 05.02 Frequency Hoping Algorithm, MAI is a function
of TDMA Frame number (FN), Hoping Sequence Number (HSN) and
Mobile Allocation Index Offset (MAIO). HSN determines the operation
track of frequencies during the frequency hopping process. Using
different HSN for cells having same MA can avoid frequency utilization
conflict between adjacent cells during the frequency hopping process.
Different timeslots can share the same group of MA and the
corresponding HSN. When HSN = 0, it is a special frequency hopping
(that is, circular frequency hopping).
For the cells close to each other with the same MA, different HSNs can
ensure that there is no conflict of frequency utilization during the FH
process.
For example, if HSN [(BCC6) +1, (BCC6) +6], then each cell may
use any of the 6 HSNs. The remaining 0 and 49..63 are used in other

Description

special cases. Use 0 by default for simplicity.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

None

5-808
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value
Configuration Reason

None

Configuration Rule and

This parameter should be set according to the radio network planning.

Adjustment Suggestion

HSN is not recommended to set to 0.

Change Mode

Offline
ZGO-04-03-001 Synthesized Frequency Hopping

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Frequency

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Hopping System
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.8.5 Frequency hopping mode (FreqHopMode)


Full Name

Frequency hopping mode

Abbreviation

FreqHopMode

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the mode of frequency hopping.

Managed Object

Cell
1: Baseband Frequency Hopping

Value Range and Step

2: RF Frequency Hopping

Unit

None

Default Value

2: RF Frequency Hopping

Default Value
Configuration Reason

None

5-809
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline
ZGO-04-03-001 Synthesized Frequency Hopping

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Frequency


Hopping System

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.8.6 Hopping group ID (BhGroupId)


Full Name

Hopping group ID

Abbreviation

BhGroupId

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the group ID for base band frequency group.

Managed Object

Cell

Value Range and Step

0..255

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline

5-810
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Frequency

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Hopping System
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.8.7 MA Frequency List Number (MaFreqNum)


Full Name

MA Frequency List Number

Abbreviation

MaFreqNum

3GPP Name

None

3GPP Reference

None

Description

quency hopping group.

Managed Object

Cell

Value Range and Step

1..64

Unit

None

Default Value

None

This parameter provides a list of absolute RF channel number in a fre-

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the radio network planning.

Change Mode

Offline
ZGO-04-03-001 Synthesized Frequency Hopping

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

None

5-811
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Frequency


Hopping System

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9 PS Handover Control Parameters


PS handover control parameters are divided into six sub-interfaces.

5.9.1 Handover Pretreatment Parameters


5.9.1.1 Site ID
Full Name

Site ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None

Description

This parameter means the site ID. It cannot be modified.


Consistent with managed element ID for SDR.

Managed Object

Cell

Value Range and Step

1 ~ 1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None
5-812

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover Con-

OMC Access Path


Parameter

Modifying

Version
Parameter

trol->Handover Pretreatment

None
Modifying

Detail

None

5.9.1.2 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter means the BTS ID. It cannot be modified.

Description

It is consistent with the sector ID of SDR.

Managed Object

Cell
1 ~ 24
The following lists the maximum number of BtsIds of each site type.
l

OB06: 3

BS20: 3

BS21: 3

BS21V20: 3

BS30: 3

BS30V12: 3

B8112: 6

M8202: 6

M8206: 6

B8018: 6

S8001: 1

Value Range and Step

SDR: 24

Unit

None

5-813
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Sorted by practice

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover Con-

OMC Access Path


Parameter

Modifying

Version
Parameter

trol->Handover Pretreatment

None
Modifying

Detail

None

5.9.1.3 PS handover control ID (PsHocId)


Full Name

PS handover control ID

Abbreviation

PsHocId

3GPP Name

None

3GPP Reference

None

Description

This parameter means the ID of PS handover control. It cannot be modified.

Managed Object

Cell

Value Range and Step

1~2

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None
5-814

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover Con-

OMC Access Path


Parameter

Modifying

Version
Parameter

trol->Handover Pretreatment

None
Modifying

Detail

None

5.9.1.4 Number of zero allowed in AV (ZeroAllowed)


Full Name

Number of zero allowed in AV

Abbreviation

ZeroAllowed

3GPP Name

None

3GPP Reference

None
According to the GSM Specifications, the MS can only report the
measurement data of six adjacent cells with the strongest signal
strength. Therefore, the measurement results of adjacent cells recorded
by BSC may be discontinuous, and the measurement data of the missing
cells shall thus be recorded as 0 (that is, less than -110dBm).
To avoid the negative impact of 0 on averaging, suppose occasional 0 is
allowed and is not used in averaging, but excessive occurrences of 0
indicate that the signals of this adjacent cell are too poor. If the number
of zeroes in used for average calculation exceeds Number of zero
allowed in AV, then measurement average equals to sum of reported
values divided by Neighboring cell.
To be specific, during averaging, if the count of 0s in the sampling count
exceeds "ZeroAllowed", these sampling values are hardly reliable, and
the measurement average will be the sum of the reported values divided
by NCellWindow. If the count of 0s in the reported values does not

Description

exceed "ZeroAllowed", these sampling values are much reliable and the

5-815
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

measurement average will be the sum of the reported values divided by


(NCellWindow the count of 0s).
Managed Object

Cell
0..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion

Excessive occurrences of zero indicate that the adjacent cells are of


poor signal strength. It is recommended to set the value as small as
possible, in order to select the adjacent cell with good signal.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.1.5 Uplink power level (HoUlLevWindow)


Full Name

Uplink power level

Abbreviation

HoUlLevWindow

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008 810

5-816
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

In the GSM system, BSC makes handover decision according to the


measurement data. To avoid the negative impact of burst measurement
values resulting from complicated radio transmission, BSC, when
making handover decision, no longer uses the original measurement
data but uses a series of average values of the measurement data.
This parameter represents the window size used to calculate the
average value of the uplink signal intensity. This size is the number of
Description

samples used in averaging.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

12

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.1.6 Downlink power level (HoDlLevWindow)


Full Name

Downlink power level

5-817
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

HoDlLevWindow

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008 810


In the GSM system, BSC makes handover decision according to the
measurement data. To avoid the negative impact of burst measurement
values resulting from complicated radio transmission, BSC, when
making handover decision, no longer uses the original measurement
data but uses a series of average values of the measurement data.
This parameter "HoDlLevWindow" is the size of the window used to
calculate the average value of downlink signal strength. This size is the

Description

number of samples used in averaging.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-818
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.9.1.7 Uplink quality (HoUlQualWindow)


Full Name

Uplink quality

Abbreviation

HoUlQualWindow

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008 810


In the GSM system, BSC makes handover decision according to the
measurement data. To avoid the negative impact of burst measurement
values resulting from complicated radio transmission, BSC, when
making handover decision, no longer uses the original measurement
data but uses a series of average values of the measurement data.
This parameter represents the window size used to calculate the
average value of the uplink signal quality. This size is the number of

Description

samples used in averaging.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

12

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

5-819
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.9.1.8 Downlink quality (HoDlQualWindow)


Full Name

Downlink quality

Abbreviation

HoDlQualWindow

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008 810


In the GSM system, BSC makes handover decision according to the
measurement data. To avoid the negative impact of burst measurement
values resulting from complicated radio transmission, BSC, when
making handover decision, no longer uses the original measurement
data but uses a series of average values of the measurement data.
The parameter of handover downlink quality average window
"HoDlQualWindow" is the size of the window used to calculate the
average value of downlink signal quality. This size is the number of

Description

samples used in averaging.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-820
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.1.9 Distance (DistanceWindow)


Full Name

Distance

Abbreviation

DistanceWindow

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


In the GSM system, BSC makes handover decision according to the
measurement data. To avoid the negative impact of burst measurement
values resulting from complicated radio transmission, BSC, when
making handover decision, no longer uses the original measurement
data but uses a series of average values of the measurement data.
This parameter represents the window size (number of sample values)
used to calculate the average value of the distance (actually the time
advance, TA) from the MS to BTS. This size is the number of samples

Description

used in averaging.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.
Configuration of the value is in accordance with the general condition. If

Configuration Rule and

the value is too small, it is difficult to select the adjacent cell as the target

Adjustment Suggestion

cell. The larger the value is, it is more difficult to select the adjacent
cell as the target cell.

Change Mode

Offline

Related features

None

Related Parameters

None

5-821
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.1.10 Neighboring cell (NCellWindow)


Full Name

Neighboring cell

Abbreviation

NCellWindow

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


In the GSM system, BSC makes handover decision according to the
measurement data. To avoid the negative impact of burst measurement
values resulting from complicated radio transmission, BSC, when
making handover decision, no longer uses the original measurement
data but uses a series of average values of the measurement data.
This parameter represents the window size used to calculate the the
average value of the adjacent cell signal strength. This size is the

Description

number of samples used in averaging.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.
Configuration of the value is in accordance with the general condition. If

Configuration Rule and

the value is too small, it is difficult to select the adjacent cell as the target

Adjustment Suggestion

cell. The larger the value is, it is more difficult to select the adjacent
cell as the target cell.
5-822

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Pretreatment

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2 Handover Level Parameters


5.9.2.1 Uplink receive level Threshold (HoUlLevThs)
Full Name

Uplink receive level Threshold

Abbreviation

HoUlLevThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend upon
the received average value.
Uplink receiving intensity is one of the causes for handover. The decision
process is as follows: For the latest N average values of uplink signal
strength, if P of the N values fall below relevant threshold value, perform
handover to improve the uplink signal strength.
The parameter "HoUlLevThs" defines the related threshold, the
parameter "HoUlLevN" defines the related N value, and the parameter
"HoUlLevP" defines the related P value.If this handover condition is met,
an internal handover is usually performed in the cell.
Generally, the value of "HoUlLevThs" shall be less than the threshold for
uplink power control (increase). That is, perform power control first. If

Description

power control does not work, perform handover.

5-823
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

Cell
0..63;
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
......
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

18

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.2 Uplink receive level Value N (HoUlLevN)


Full Name

Uplink receive level Value N

Abbreviation

HoUlLevN

3GPP Name

None
5-824

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend upon
the received average value.
Uplink receiving intensity is one of the causes for handover. The decision
process is as follows: For the latest N average values of uplink signal
strength, if P of the N values fall below relevant threshold value, perform
handover to improve the uplink signal strength.
The parameter "HoUlLevThs" defines the related threshold, the
parameter "HoUlLevN" defines the related N value, and the parameter
"HoUlLevP" defines the related P value.If this handover condition is met,
an internal handover is usually performed in the cell.
Generally, the value of "HoUlLevThs" shall be less than the threshold for
uplink power control (increase). That is, perform power control first. If

Description

power control does not work, perform handover.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

5-825
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.9.2.3 Uplink receive level Value P (HoUlLevP)


Full Name

Uplink receive level Value P

Abbreviation

HoUlLevP

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend upon
the received average value.
Uplink receiving intensity is one of the causes for handover. The decision
process is as follows: For the latest N average values of uplink signal
strength, if P of the N values fall below relevant threshold value, perform
handover to improve the uplink signal strength.
The parameter "HoUlLevThs" defines the related threshold, the
parameter "HoUlLevN" defines the related N value, and the parameter
"HoUlLevP" defines the related P value.If this handover condition is met,
an internal handover is usually performed in the cell.
Generally, the value of "HoUlLevThs" shall be less than the threshold for
uplink power control (increase). That is, perform power control first. If

Description

power control does not work, perform handover.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None
5-826

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.4 Downlink receive level Threshold (HoDlLevThs)


Full Name

Downlink receive level Threshold

Abbreviation

HoDlLevThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend upon
the received average value.Downlink receiving intensity is one of the
causes for handover. The decision process is as follows: For the latest
N average values of downlink signal strength, if P of the N values
fall below relevant threshold value, perform handover to improve the
downlink signal strength.
The parameter "HoDlLevThs" defines the related threshold, the
parameter "HoDlLevN" defines the related N value, and the parameter
"HoDlLevP" defines the related P value.
Usually the value of "HoDlLevThs" shall be less than the threshold for
downlink power control (increase). That is, power control should be
performed first. If power control does not work, perform handover. This
parameter can be set to 15 by default (i.e. -96 dBm..-95 dBm), which
is 3 dB larger than the minimum access level value (RxLevAccessMin)

Description

of the cell.

Managed Object

Cell
0..63;
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
......
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1
5-827

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

18

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.5 Downlink receive level Value N (HoDlLevN)


Full Name

Downlink receive level Value N

Abbreviation

HoDlLevN

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810

5-828
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

According to the GSM specifications, handover decisions depend upon


the received average value.Downlink receiving intensity is one of the
causes for handover. The decision process is as follows: For the latest
N average values of downlink signal strength, if P of the N values
fall below relevant threshold value, perform handover to improve the
downlink signal strength.
The parameter "HoDlLevThs" defines the related threshold, the
parameter "HoDlLevN" defines the related N value, and the parameter
"HoDlLevP" defines the related P value.
Usually the value of "HoDlLevThs" shall be less than the threshold for
downlink power control (increase). That is, power control should be
performed first. If power control does not work, perform handover. This
parameter can be set to 15 by default (i.e. -96 dBm..-95 dBm), which
is 3 dB larger than the minimum access level value (RxLevAccessMin)
Description

of the cell.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

5-829
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.6 Downlink receive level Value P ( HoDlLevP)


Full Name

Downlink receive level Value P

Abbreviation

HoDlLevP

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend upon
the received average value. Downlink receiving intensity is one of the
causes for handover. The decision process is as follows: For the latest
N average values of downlink signal strength, if P of the N values
fall below relevant threshold value, perform handover to improve the
downlink signal strength.
The parameter "HoDlLevThs" defines the related threshold, the
parameter "HoDlLevN" defines the related N value, and the parameter
"HoDlLevP" defines the related P value.
Usually the value of "HoDlLevThs" shall be less than the threshold for
downlink power control (increase). That is, power control should be
performed first. If power control does not work, perform handover. This
parameter can be set to 15 by default (i.e. -96 dBm..-95 dBm), which
is 3 dB larger than the minimum access level value (RxLevAccessMin)

Description

of the cell.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

5-830
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.7 Uplink receive quality Threshold (HoUlQualThs)


Full Name

Uplink receive quality Threshold

Abbreviation

HoUlQualThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend upon
the received average value. The uplink receive quality is one of the
causes for handover. The decision process is as follows: For the latest
N average values of uplink signal quality, if P of the N values rise above
relevant threshold value, perform handover to improve the uplink signal
quality.
The parameter "HoUlQualThs" defines the related threshold, the
parameter "HoUlQualN" defines the related N value, and the parameter
"HoUlQualP" defines the related P value.
Generally, the value of "HoUlQualThs" shall be greater than the threshold
for uplink power control (increase). That is, perform power control first. If

Description

power control does not work, perform handover.

Managed Object

Cell
0..31

Value Range and Step

Step: 1

Unit

None

Default Value

15

5-831
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.8 Uplink receive quality Value N (HoUlQualN)


Full Name

Uplink receive quality Value N

Abbreviation

HoUlQualN

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend upon
the received average value. The uplink receive quality is one of the
causes for handover. The decision process is as follows: For the latest
N average values of uplink signal quality, if P of the N values rise above
relevant threshold value, perform handover to improve the uplink signal
quality.
The parameter "HoUlQualThs" defines the related threshold, the
parameter "HoUlQualN" defines the related N value, and the parameter

Description

"HoUlQualP" defines the related P value.

5-832
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Generally, the value of "HoUlQualThs" shall be greater than the threshold


for uplink power control (increase). That is, perform power control first. If
power control does not work, perform handover.
Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.9 Uplink receive quality Value P (HoUlQualP)


Full Name

Uplink receive quality Value P

Abbreviation

HoUlQualP

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810

5-833
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

According to the GSM specifications, handover decisions depend upon


the received average value. The uplink receive quality is one of the
causes for handover. The decision process is as follows: For the latest
N average values of uplink signal quality, if P of the N values rise above
relevant threshold value, perform handover to improve the uplink signal
quality.
The parameter "HoUlQualThs" defines the related threshold, the
parameter "HoUlQualN" defines the related N value, and the parameter
"HoUlQualP" defines the related P value.
Generally, the value of "HoUlQualThs" shall be greater than the threshold
for uplink power control (increase). That is, perform power control first. If
Description

power control does not work, perform handover.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-834
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.9.2.10 Downlink receive quality Threshold (HoDlQualThs )


Full Name

Downlink receive quality Threshold

Abbreviation

HoDlQualThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend
upon the received average value. Downlink receive quality is one of
the causes for handover. The decision process is as follows: For the
latest N average values of downlink signal quality, if P of the N values
rise above relevant threshold value, perform handover to improve the
downlink signal quality.
Parameter "HoDlQualThs" defines the related threshold, parameter
"HoDlQualN" defines the related N value, and parameter "HoDlQualP"
defines the related P value.
In general, the downlink receive quality threshold shall be larger than
downlink power control (increase) threshold, i.e. perform power control

Description

first, and then perform handover if power control fails.

Managed Object

Cell
0..31

Value Range and Step

Step: 1

Unit

None

Default Value

15

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-835
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.11 Downlink receive quality Value N (HoDlQualN)


Full Name

Downlink receive quality Value N

Abbreviation

HoDlQualN

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend
upon the received average value. Downlink receive quality is one of
the causes for handover. The decision process is as follows: For the
latest N average values of downlink signal quality, if P of the N values
rise above relevant threshold value, perform handover to improve the
downlink signal quality.
Parameter "HoDlQualThs" defines the related threshold, parameter
"HoDlQualN" defines the related N value, and parameter "HoDlQualP"
defines the related P value.
In general, the downlink receive quality threshold shall be larger than
downlink power control (increase) threshold, i.e. perform power control

Description

first, and then perform handover if power control fails.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria


5-836

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.12 Downlink receive quality Value P (HoDlQualP)


Full Name

Downlink receive quality Value P

Abbreviation

HoDlQualP

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend
upon the received average value. Downlink receive quality is one of
the causes for handover. The decision process is as follows: For the
latest N average values of downlink signal quality, if P of the N values
rise above relevant threshold value, perform handover to improve the
downlink signal quality.
Parameter "HoDlQualThs" defines the related threshold, parameter
"HoDlQualN" defines the related N value, and parameter "HoDlQualP"
defines the related P value.
In general, the downlink receive quality threshold shall be larger than
downlink power control (increase) threshold, i.e. perform power control

Description

first, and then perform handover if power control fails.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

5-837
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.13 Iplink receive level of intra-ho Threshold (IntraHoUlLevThs)


Full Name

Iplink receive level of intra-ho Threshold

Abbreviation

IntraHoUlLevThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend upon
the received average value. The uplink co-frequency interference is one
of the causes for handover. The decision process is as follows: If the
handover condition of uplink quality is met and P out of the N values (the
latest N average values of uplink signal strength) rise above relevant
threshold value, perform handover. The handover is due to strong uplink
co-frequency interference.
The parameter "IntraHoUlLevThs" defines the related threshold, the

Description

parameter "IntraHoUlLevN" defines the related N value, and the

5-838
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

parameter "IntraHoUlLevP" defines the related P value. If this handover


condition is met, an internal handover is usually performed in the cell.
Usually, the value of "IntraHoUlLevThs" shall be more than the threshold
for uplink power control (decrease).
Managed Object

Cell
0..63;
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
......
62: -49 dBm .. -48 dBm;
63: > -48 dBm

Value Range and Step

Step: 1

Unit

None

Default Value

35

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-839
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.9.2.14 Iplink receive level of intra-ho Value N (IntraHoUlLevN)


Full Name

Iplink receive level of intra-ho Value N

Abbreviation

IntraHoUlLevN

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend upon
the received average value. The uplink co-frequency interference is one
of the causes for handover. The decision process is as follows: If the
handover condition of uplink quality is met and P out of the N values (the
latest N average values of uplink signal strength) rise above relevant
threshold value, perform handover. The handover is due to strong uplink
co-frequency interference.
The parameter "IntraHoUlLevThs" defines the related threshold, the
parameter "IntraHoUlLevN" defines the related N value, and the
parameter "IntraHoUlLevP" defines the related P value.If this handover
condition is met, an internal handover is usually performed in the cell.
Usually, the value of "IntraHoUlLevThs" shall be more than the threshold

Description

for uplink power control (decrease).

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

5-840
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.15 Iplink receive level of intra-ho Value P (IntraHoUlLevP)


Full Name

Iplink receive level of intra-ho Value P

Abbreviation

IntraHoUlLevP

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend upon
the received average value. The uplink co-frequency interference is one
of the causes for handover. The decision process is as follows: If the
handover condition of uplink quality is met and P out of the N values (the
latest N average values of uplink signal strength) rise above relevant
threshold value, perform handover. The handover is due to strong uplink
co-frequency interference.
The parameter "IntraHoUlLevThs" defines the related threshold, the
parameter "IntraHoUlLevN" defines the related N value, and the
parameter "IntraHoUlLevP" defines the related P value.If this handover
condition is met, an internal handover is usually performed in the cell.
Usually, the value of "IntraHoUlLevThs" shall be more than the threshold

Description

for uplink power control (decrease).

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline

5-841
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

ZGB-02-02-001 Basic Handover


Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.16 Downlink receive level of intra-ho Threshold (IntraHoDlLevThs)


Full Name

Downlink receive level of intra-ho Threshold

Abbreviation

IntraHoDlLevThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend upon
the received average value. The downlink co-frequency interference is
one of the causes for handover. The decision process is as follows: If
the downlink quality condition for handover is met and P out of N recent
downlink signal strength averages are more than the related threshold,
handover shall be performed, because the downlink co-frequency
interference is very strong.
The parameter "IntraHoDlLevThs" defines the related threshold, the
parameter "IntraHoDlLevN" defines the related N value, and the
parameter "IntraHoDlLevP" defines the related P value.If this handover
condition is met, an internal handover is usually performed in the cell.
Usually the value of "IntraHoDlLevThs" shall be less than (or equal to)

Description

the threshold for downlink power control (decrease).

Managed Object

Cell

5-842
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

0..63;
0: < -110 dBm;
1: -110 dBm .. -109 dBm;
......
62: -49 dBm .. -48 dBm;
63: > -48 dBm
Value Range and Step

Step: 1

Unit

None

Default Value

40

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.17 Downlink receive level of intra-ho Value N (IntraHoDlLevN)


Full Name

Downlink receive level of intra-ho Value N

Abbreviation

IntraHoDlLevN

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


5-843

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

According to the GSM specifications, handover decisions depend upon


the received average value. The downlink co-frequency interference is
one of the causes for handover. The decision process is as follows: If
the downlink quality condition for handover is met and P out of N recent
downlink signal strength averages are more than the related threshold,
handover shall be performed, because the downlink co-frequency
interference is very strong.
The parameter "IntraHoDlLevThs" defines the related threshold, the
parameter "IntraHoDlLevN" defines the related N value, and the
parameter "IntraHoDlLevP" defines the related P value. If this handover
condition is met, an internal handover is usually performed in the cell.
Usually, the value of "IntraHoDlLevThs" shall be less than (or equal to)
Description

the threshold for downlink power control (decrease).

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Level
Parameter Modifying
Version

None

5-844
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.9.2.18 Downlink receive level of intra-ho Value P (IntraHoDlLevP)


Full Name

Downlink receive level of intra-ho Value P

Abbreviation

IntraHoDlLevP

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


According to the GSM specifications, handover decisions depend upon
the received average value. The downlink co-frequency interference is
one of the causes for handover. The decision process is as follows: If
the downlink quality condition for handover is met and P out of N recent
downlink signal strength averages are more than the related threshold,
handover shall be performed, because the downlink co-frequency
interference is very strong.
The parameter "IntraHoDlLevThs" defines the related threshold, the
parameter "IntraHoDlLevN" defines the related N value, and the
parameter "IntraHoDlLevP" defines the related P value. If this handover
condition is met, an internal handover is usually performed in the cell.
Usually, the value of "IntraHoDlLevThs" shall be less than (or equal to)

Description

the threshold for downlink power control (decrease).

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

The period to submit an uplink measurement report is 20 ms and the


period to submit an downlink measurement report is 200 ms, so the
average value of the uplink is larger than that of the downlink.
Offline
ZGB-02-02-001 Basic Handover

Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None
5-845

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.19 Rapid handover Threshold (RapidHoThs)


Full Name

Rapid handover Threshold

Abbreviation

RapidHoThs

3GPP Name

None

3GPP Reference

None
During fast fading handover, some parameters shall be used.
"RapidHoThs" is a signal strength threshold. If the measured signal
strength values of a call are consecutively lower than this threshold, it
meets the condition for rapid attenuation handover. Candidate cells are
special associated cells among the adjacent cells.
"RapidHoThs" can be set as 15 (that is, -96dBm ~ -95dBm) by default,
the same as the level threshold of ordinary handover. "RapidHoN" is a
counter value. That is, the minimum times that the measured values of

Description

the signal strength of the call are consecutively lower than the threshold.

Managed Object

Cell
0.0.62

Value Range and Step

Step: 1

Unit

None

Default Value

15

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.
Rapid handover is characterized by fast speed, so the handover

Configuration Rule and

threshold should not be too high. The MS will move to the area with high

Adjustment Suggestion

cell level soon. N value cannot be too large, otherwise the timeliness of
handover judgement will be influenced.

Change Mode

Offline

5-846
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.20 Rapid handover Value N (RapidHoN)


Full Name

Rapid handover Value N

Abbreviation

RapidHoN

3GPP Name

None

3GPP Reference

None
During fast fading handover, some parameters shall be used.
"RapidHoThs" is a signal strength threshold. If the measured signal
strength values of a call are consecutively lower than this threshold, it
meets the condition for rapid attenuation handover. Candidate cells are
special associated cells among the adjacent cells.
"RapidHoThs" can be set as 15 (that is, -96dBm ~ -95dBm) by default,
the same as the level threshold of ordinary handover. "RapidHoN" is a
counter value. That is, the minimum times that the measured values of

Description

the signal strength of the call are consecutively lower than the threshold.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.
5-847

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Rapid handover is characterized by fast speed, so the handover


Configuration Rule and

threshold should not be too high. The MS will move to the area with high

Adjustment Suggestion

cell level soon. N value cannot be too large, otherwise the timeliness of
handover judgement will be influenced.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Level
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.21 Macro to micro handover Threshold (MacroMicroHoThs)


Full Name

Macro to micro handover Threshold

Abbreviation

MacroMicroHoThs

3GPP Name

None

3GPP Reference

3GPP TS 45.008 810


During macro-micro handover, some parameters shall be used. That
is, a signal strength threshold and a counter value. The macro-micro
handover threshold is a value of signal strength threshold. If the
measured signal strength of an adjacent micro cell is higher than
MacroMicroHoThs (threshold value) for certain times, the call can be
handed over to this adjacent cell.
In this way, the MS moving slowly can enter the lower layer adjacent
cell. The times can be determined by the MacroMicroHoN parameter in
each adjacent cell. The setting of the parameter "MacroMicroHoN" in
the cell is related to this cell size and the standard used in measuring the

Description

MS moving speed.

5-848
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Cell
0..63
0: < -110 dBm;
1: -110dBm..-109dBm;
...
62: -49 dBm .. -48 dBm;
63: >-48dBm

Value Range and Step

Step: 1

Unit

None

Default Value

20

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.
The higher the threshold is, it is more likely to perform macro-micro

Configuration Rule and

handover. The setting of the parameter "MacroMicroHoN" in the cell

Adjustment Suggestion

is related to this cell size and the standard used in measuring the MS
moving speed.

Change Mode

Offline

Related features

ZGO-02-02-001 Handover Between Macro- and Micro-cells

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.22 Macro to micro handover Value N (MacroMicroHoN)


Full Name

Macro to micro handover Value N

Abbreviation

MacroMicroHoN

3GPP Name

None
5-849

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

3GPP TS 45.008 810


During macro-micro handover, some parameters shall be used. That
is, a signal strength threshold and a counter value. The macro-micro
handover threshold is a value of signal strength threshold. If the
measured signal strength of an adjacent micro cell is higher than
MacroMicroHoThs (threshold value) for certain times, the call can be
handed over to this adjacent cell.
In this way, the MS moving slowly can enter the lower layer adjacent
cell. The times can be determined by the MacroMicroHoN parameter in
each adjacent cell. The setting of the parameter "MacroMicroHoN" in
the cell is related to this cell size and the standard used in measuring the

Description

MS moving speed.

Managed Object

Cell
1..255

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.
The higher the threshold is, it is more likely to perform macro-micro

Configuration Rule and

handover. The setting of the parameter "MacroMicroHoN" in the cell

Adjustment Suggestion

is related to this cell size and the standard used in measuring the MS
moving speed.

Change Mode

Offline

Related features

ZGO-02-02-001 Handover Between Macro- and Micro-cells

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None
5-850

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.9.2.23 Distance handover Value N (DistanceN)


Full Name

Distance handover Value N

Abbreviation

DistanceN

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008
According to GSM specifications, arbitration for SDCCH can be
conducted after a series of average values of uplink and downlink signal
strength are obtained.
The distance between MS and BTS can impact the handover. The
arbitration process is as follows: For the latest N average values of TA
(distance), if P of the N values are higher than the relevant threshold
value, perform a handover. The handover happens due to MS being out
of the cell serving range.
The parameter DistanceN defines the relevant N value, and parameter

Description

DistanceP defines the relevant P value.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

To ensure the correct and quick handover, it is recommended to set

Configuration Reason

this parameter 3.
If the value is set low, there will few samplings and wrong arbitration

Configuration Rule and

might be made.

Adjustment Suggestion

If the value is set high, arbitration for handover needs more time and
call drop will happen.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

[BSC]ShoEnable
[Cell]DistanceP

Relationship

This parameter takes effect when handovers on SDCCH are supported.


The parameter value should not be lower than DistanceP.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-851
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.24 Distance handover Value P (DistanceP)


Full Name

Distance handover Value P

Abbreviation

DistanceP

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008
According to GSM specifications, arbitration for SDCCH can be
conducted after a series of average values of uplink and downlink signal
strength are obtained.
The distance between MS and BTS can impact the handover. The
arbitration process is as follows: For the latest N average values of TA
(distance), if P of the N values are higher than the relevant threshold
value, perform a handover. The handover happens due to MS being out
of the cell serving range.
The parameter DistanceN defines the relevant N value, and parameter

Description

DistanceP defines the relevant P value.

Managed Object

Cell
1..20

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

To ensure the correct and quick handover, it is recommended to set

Configuration Reason

this parameter 2.
If the value is set low, it will be easy to meet the arbitration conditions

Configuration Rule and

and handover will happen frequently.

Adjustment Suggestion

If the value is set high, it will be difficult to meet the arbitration conditions
and handover will not happen frequently.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

5-852
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

[BSC]ShoEnable
[Cell]DistanceN

Relationship

This parameter takes effect when handovers on SDCCH are supported.


The parameter value should not be higher than DistanceN.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.25 PBGT handover Value N (PBGTHoN)


Full Name

PBGT handover Value N

Abbreviation

PBGTHoN

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008 810


This parameter indicates the value N in PBGT handover. In PBGT handover, if there are P values of PBGT in N PBGT satisfying the handover

Description

determination condition, the PBGT handover conditions are satisfied.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

Usually, if the value is too small, times of handover attempts and


execution will be influenced. The larger the value is, it is more difficult to
perform handover, and call drop is more likely to occur.
Offline

5-853
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

ZGB-02-02-001 Basic Handover


Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.2.26 PBGT handover Value P (PBGTHoP)


Full Name

PBGT handover Value P

Abbreviation

PBGTHoP

3GPP Name

N1..N8, P1..P8

3GPP Reference

3GPP TS 45.008 810


This parameter indicates the value N in PBGT handover. In PBGT handover, if there are P values of PBGT in N PBGT satisfying the handover

Description

determination condition, the PBGT handover conditions are satisfied.

Managed Object

Cell
1..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion
Change Mode

Usually, if the value is too small, times of handover attempts and


execution will be influenced. The larger the value is, it is more difficult to
perform handover, and call drop is more likely to occur.
Offline

5-854
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

ZGB-02-02-001 Basic Handover


Related features

ZGB-02-02-002 Basic Handover Decision Criteria

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Level

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.3 Handover Condition Parameters


5.9.3.1 Max time advance threshold between MS and BTS (DistanceThs)
Full Name

Max time advance threshold between MS and BTS

Abbreviation

DistanceThs

3GPP Name

Internal

3GPP Reference

None
The distance from MS to BTS is also one of the causes for handover.
The decision process is as follows: For the latest N average values of
TA (distance), if P of the N values rises above relevant threshold value,
perform handover. The handover is due to MS being out of the serving

Description

range of the cell.

Managed Object

Cell
Common cell: 0 ..0.63; Extended cell: 0..0.219

Value Range and Step

Step: 1

Unit

None

Default Value

60

Default Value

When the TA reaches the maximum TA that the cell supports, handover

Configuration Reason

is initiated.

5-855
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

After the distance handover algorithm is enabled, configuration of this


Configuration Rule and

parameter is dependent upon the actual requirement. Generally, the

Adjustment Suggestion

distance handover algorithm is seldom used, so it is recommended to


reserve the default value.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Condition
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.3.2 MIN interval between inter-cell handover (HoMinInterval)


Full Name

MIN interval between inter-cell handover

Abbreviation

HoMinInterval

3GPP Name

None

3GPP Reference

None
During PS handover, the system uses this parameter to restrict frequent
inter-cell handover, and guarantee the communication quality and
system performance, so as to prevent the MS from performing handover
to other cells soon after it handovers to the cell (usually, such a case
occurs at the boundary regions between two cells).
Inter-cell handover takes place when the timer exceeds the defined
interval value from the last inter-cell handover of MS. This parameter
only affects the inter-cell handover, but not common intra-cell or inter-cell
concentric handover. In addition, micro-cell has its own handover policy,
so this parameter is only effective for macro-cell layer and its above layer.
For macro-cell, the default value can be 5; for micro-cell, the default

Description

value can only be 0.


5-856

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Cell
0..31

Value Range and Step

Step: 1

Unit

Default Value

Default Value
Configuration Reason

Setting of the default value is in accordance with CS services.

Configuration Rule and

The value is to keep the MS from handover to the original cell. The

Adjustment Suggestion

longer the time is, the longer is the handover to the original cell.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.3.3 Prior layer selecting parameter on signal level/quality (LayerPriority)


Full Name

Prior layer selecting parameter on signal level/quality

Abbreviation

LayerPriority

3GPP Name

None

3GPP Reference

None

5-857
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

When the conditions of level/quality (signal level and signal quality)


handover are satisfied, three options are available to select and
sequence the candidate cells for a call:
First hand over to adjacent cells at the upper layer of the local cell, then
to those at the same layer, and finally to other adjacent cells;
Adjacent cells in the same layer of serving cell have the highest priority
for handover, then adjacent cells in the upper layer, and finally the other
adjacent cells.
All adjacent cells are treated in the same way.
This parameter determines to select one of the above three methods.
During handover control process, this parameter has higher priority than
normal adjacent cells.
Value range:
1 (UPPER_LAYER): adjacent cell at above layer first, same layer next,
other adjacent cells finally;
2 (SAME_LAYER): adjacent cell at same layer first, above layer next,
other adjacent cells finally;
Description

3 (ALL_LAYER): all adjacent cells are the same.

Managed Object

Cell
1..3

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value ensures to trigger this kind of handover rapidly and

Configuration Reason

accurately.

Configuration Rule and


Adjustment Suggestion

Generally, the adjacent cells at the same layer take priority.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Condition

5-858
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.3.4 Handover to same layer other band neighbor cell for PBGT permitted
(PbgtHoLayer_0)
Full Name

Handover to same layer other band neighbor cell for PBGT permitted

Abbreviation

PbgtHoLayer_0

3GPP Name

None

3GPP Reference

None
This parameter describes whether it is allowed to perform PBGT handover

Description

to the same layer adjacent cell with different frequency band.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

Setting of the default value is in accordance with CS services.

Configuration Rule and

Generally, PBGT handover is performed to the same layer or is

Adjustment Suggestion

performed to the adjacent cell with no layer relationship.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Condition

Parameter Modifying
Version

None
5-859

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

5.9.3.5 Handover to neighbor cell with no layer relation for PBGT permitted
(PbgtHoLayer_1)
Full Name

Handover to neighbor cell with no layer relation for PBGT permitted

Abbreviation

PbgtHoLayer_1

3GPP Name

None

3GPP Reference

None
This parameter describes whether it is allowed to perform PBGT handover

Description

to adjacent cell with no layer relationship.

Managed Object

Cell
0No

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

Setting of the default value is in accordance with CS services.

Configuration Rule and

Generally, PBGT handover is performed to the same layer or is

Adjustment Suggestion

performed to the adjacent cell with no layer relationship.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None
5-860

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.9.3.6 Handover to upper layer neighbor cell for PBGT permitted (PbgtHoLayer_2)
Full Name

Handover to upper layer neighbor cell for PBGT permitted

Abbreviation

PbgtHoLayer_2

3GPP Name

None

3GPP Reference

None
This parameter describes whether the PBGT handover to the upper layer

Description

adjacent cell is allowed.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

Setting of the default value is in accordance with CS services.

Configuration Rule and

Generally, PBGT handover is performed to the same layer or is

Adjustment Suggestion

performed to the adjacent cell with no layer relationship.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.3.7 Handover to under layer neighbor cell for PBGT permitted (PbgtHoLayer_3)
Full Name

Handover to under layer neighbor cell for PBGT permitted

5-861
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

PbgtHoLayer_3

3GPP Name

None

3GPP Reference

None
This parameter describes whether the PBGT handover to the lower layer

Description

adjacent cell is allowed.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

Setting of the default value is in accordance with CS services.

Configuration Rule and

Generally, PBGT handover is performed to the same layer or is

Adjustment Suggestion

performed to the adjacent cell with no layer relationship.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.3.8 Synchronism (HoPatternInd_0)


Full Name

Synchronism

Abbreviation

HoPatternInd_0

3GPP Name

None

5-862
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Reference

None
This parameter indicates the configuration that whether the
synchronization handover is allowed in this cell.
If the time advance of the destination cell BSC obtained is equal to that of

Description

the original cell, synchronization handover to this cell can be performed.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The default value is dependent upon the actual request on site.

Configuration Rule and

Synchronization handover is enabled for the cell which supports

Adjustment Suggestion

intra-cell handover.

Change Mode

Offline

Related features

ZGB-02-02-003 Handover Mode

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.3.9 Asynchronism (HoPatternInd_1)


Full Name

Asynchronism

Abbreviation

HoPatternInd_1

3GPP Name

None

3GPP Reference

None
5-863

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the configuration that whether the


asynchronous handover is allowed in this cell.
If BSC is unable to obtain the time advance of the target cell,
Description

asynchronous handover can be only performed to this cell.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

The default value is dependent upon the actual request on site.

Configuration Rule and


Adjustment Suggestion

Generally, asynchronous handover is enabled in the cell.

Change Mode

Offline

Related features

ZGB-02-02-003 Handover Mode

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.3.10 Pre-synchronism (HoPatternInd_3)


Full Name

Pre-synchronism

Abbreviation

HoPatternInd_3

3GPP Name

None

3GPP Reference

None

5-864
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter indicates the configuration that whether the


pre-synchronization handover is allowed in this cell.
If BSC knows the time advance of the destination cell, and considers the
time difference when it issues handover command, pre-synchronization
Description

handover can be performed

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

The default value is dependent upon the actual request on site.

Configuration Rule and


Adjustment Suggestion

Currently, this function is not supported and is disabled.

Change Mode

Offline

Related features

ZGB-02-02-003 Handover Mode

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Condition

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.4 Handover Control Parameters


5.9.4.1 Allow intra-cell handover attempt due to uplink interference (HoControl_1)
Full Name

Allow intra-cell handover attempt due to uplink interference

Abbreviation

HoControl_1

5-865
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

None

3GPP Reference

None
This parameter indicates whether to allow intra-cell handover due to
uplink interference.

Description

It is the 1st bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.4.2 Allow intra-cell handover attempt due to downlink interference (HoControl_2)


Full Name

Allow intra-cell handover attempt due to downlink interference

Abbreviation

HoControl_2

3GPP Name

None

3GPP Reference

None
5-866

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter indicates whether to allow intra-cell handover due to


downlink interference.
Description

It is the 2nd bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.4.3 Allow standard PBGT handover (HoControl_4)


Full Name

Allow standard PBGT handover

Abbreviation

HoControl_4

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates whether to allow standard PBGTPS handover.

Managed Object

Cell
5-867

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value

PBGT handover is common in the ordinary network and the handover

Configuration Reason

effect is good. The function is enabled by default.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Control
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.4.4 Allow handover due to distance (HoControl_3)


Full Name

Allow handover due to distance

Abbreviation

HoControl_3

3GPP Name

None

3GPP Reference

None

Description

This parameter determines whether to allow PS handover due to distance.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

5-868
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value
Configuration Reason

This handover should not be enabled in normal network.

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.4.5 Allow automatic handover based on traffic (HoControl_5)


Full Name

Allow automatic handover based on traffic

Abbreviation

HoControl_5

3GPP Name

None

3GPP Reference

None
This parameter indicates whether to allow automatic handover based
on traffic.

Description

It is the 5th bit of the HoControl field in DWORD type.

Managed Object

Cell
0: No;

Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


5-869

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and

Currently, the function of this version is not commercially used, so the

Adjustment Suggestion

value should not be modified.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.4.6 Enable rapid handover (HoControl_6)


Full Name

Enable rapid handover

Abbreviation

HoControl_6

3GPP Name

None

3GPP Reference

None

Description

This parameter determines whether to allow rapid handover.

Managed Object

Cell

Value Range and


Step

Yes/No

Unit

None

Default Value

No

Default Value
Configuration
Reason

None

Configuration Rule
and Adjustment
Suggestion

None
5-870

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related Features

None

Related
Parameters

None

Relationship

None

Related Interfaces

None

Impact on
Equipment

Impact on service

Negotiation With
CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Control

Parameter
Modifying Version

None

Parameter
Modifying Detail

None

5.9.4.7 Enable macro to micro handover (HoControl_7)


Full Name

Enable macro to micro handover

Abbreviation

HoControl_7

3GPP Name

None

3GPP Reference

None

Description

This parameter determines whether to allow Macro-Micro delay handover.

Managed Object

Cell

Value Range and


Step

Yes/No

Unit

None

Default Value

No

Default Value
Configuration
Reason

None

Configuration Rule
and Adjustment
Suggestion

None
5-871

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related Features

None

Related
Parameters

None

Relationship

None

Related Interfaces

None

Impact on
Equipment

Impact on service

Negotiation With
CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Control

Parameter
Modifying Version

None

Parameter
Modifying Detail

None

5.9.5 Other Parameters


5.9.5.1 Enable queue in handover (QueInHo)
Full Name

Enable queue in handover

Abbreviation

QueInHo

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether it is allowed to queue up to wait for

Description

channels during handover.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

Many target cells are available for handover and the interval of handover

Configuration Reason

attempts is short, so it is recommended not to enable the default value.

5-872
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and

If this function is enabled, it helps alleviate channel congestion under

Adjustment Suggestion

the busy traffic scenario.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

Yes
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Other parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.5.2 Enable queue in handver preemption in handover (PreeptInHo)


Full Name

Enable queue in handver preemption in handover

Abbreviation

PreeptInHo

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether it is allowed to preempt the channel

Description

occupied by the low-priority user.

Managed Object

Cell

Value Range and Step

1: Yes; 0: No

Unit

Cell

Default Value

No

Default Value

Preemption brings an impact on the low-priority user. Usually, the default

Configuration Reason

value can be disabled.

Configuration Rule and

The value can be enabled if you wish the high-priority user to obtain

Adjustment Suggestion

channels easily during handover, the function can be enabled.

Change Mode

Offline

5-873
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

Yes

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Other parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.5.3 Penalty time for handover failure (HoFailPenalTime)


Full Name

Penalty time for handover failure

Abbreviation

HoFailPenalTime

3GPP Name

None

3GPP Reference

None
This parameter indicates the penalty time for the target cell if the MS fails
to handover to the target cell. During the penalty time, the priority of inter-cell handover within BSC is reduced. This parameter determines the

Description

penalty duration.

Managed Object

Cell
1..255

Value Range and Step

Step: 1

Unit

The period for the BSC to receive or pre-process a measurement report

Default Value

Default Value

7 measurement report periods ensure that the MS can select to a better

Configuration Reason

cell.

Configuration Rule and

The longer the time is set, the longer is the penalty on the cell, the longer

Adjustment Suggestion

is the failure of handover to the cell.

Change Mode

Offline

Related features

None
5-874

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Other parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.5.4 Layer control value for handover on traffic (TrafficHoLayrCtl)


Full Name

Layer control value for handover on traffic

Abbreviation

TrafficHoLayrCtl

3GPP Name

None

3GPP Reference

None
This is a layer selecting parameter on traffic handover. This parameter,
together with frequency control value for handover on traffic, decides the
adjacent cells frequency band and layer selected during traffic handover.
When traffic handover condition is satisfied, as for the layer relation, four
choices are available for call selection and candidate cell arrangement.
This parameter decides which choice shall be selected. When
traffic-based handover control is implemented in traffic process, this
parameter takes priority over that of adjacent cells.
The values are as follows:
0: N, Not defined;
1: SAME, Adjacent cell and this cell are in the same layer;
2: UPPER, Adjacent cell is the upper layer of this cell;

Description

3: LOWER, Adjacent cell is the lower layer of this cell;

Managed Object

Cell
0: N, Not defined;
1: SAME, Adjacent cell and this cell are in the same layer;
2: UPPER, Adjacent cell is the upper layer of this cell;

Value Range and Step

3: LOWER, Adjacent cell is the lower layer of this cell;

5-875
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

Default Value
Configuration Reason

Usually, handover is performed to the cell in the same layer. Traffic


handover can be performed to the cell in the different layer as needed.
Handover is performed to the cell in the same layer by default.

Configuration Rule and

Usually, handover is performed to the cell in the same layer. Traffic

Adjustment Suggestion

handover can be performed to the cell in the different layer as needed.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Other parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.5.5 Frequency control value for handover on traffic (TrafficHoFreqCtl)


Full Name

Frequency control value for handover on traffic

Abbreviation

TrafficHoFreqCtl

3GPP Name

None

3GPP Reference

None
This parameter defines the control value of layer for traffic handover, i.e.
which frequency band shall be handed over to.
Basic GSM900 frequency band P-GSM (ARFCN = 1..124)
Extended GSM900 frequency band E-GSM (ARFCN = 0..124,
975..1023)
DCS1800 frequency band DCS1800 (ARFCN = 512..885)
PCS1900 frequency band PCS1900 (ARFCN = 512..810)

Description

GSM850 frequency band (ARFCN = 128..251)


5-876

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Cell
0: GSM900
1: EXT900
2: DCS1800
4: PCS1900

Value Range and Step

7: GSM850

Unit

None

Default Value

GSM900

Default Value
Configuration Reason

Setting of the default value is dependant on the actual circumstances.

Configuration Rule and


Adjustment Suggestion

Setting of the value is dependant on the actual circumstances.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Other parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.5.6 Threshold of traffic for handover (TrafficThs)


Full Name

Threshold of traffic for handover

Abbreviation

TrafficThs

3GPP Name

None

3GPP Reference

None

5-877
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If PDCH occupation rate of a cell is greater than this parameter value


(number of occupied PDCH channels / number of total PDCH channels,
not including the blocked idle channels), it indicates the cell is too busy,
Description

and traffic handover is triggered for the cell.

Managed Object

Cell
0..100

Value Range and Step

Step: 1

Unit

Default Value

80

Default Value
Configuration Reason

Setting of the default value is in accordance with CS services.

Configuration Rule and

The traffic threshold of the cell cannot be too high, so as to prevent

Adjustment Suggestion

congestion in the cell.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Other parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.6 Handover Arithmetic Parameters


5.9.6.1 Traffic handover threshold (TrafficLevThs)
Full Name

Traffic handover threshold

Abbreviation

TrafficLevThs

3GPP Name

Internal
5-878

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

3GPP Reference

None
This parameter is used for traffic handover during PS services. If the adjacent cell' s level is higher than this threshold (that is, RxLevelNcell-DwlinkLevel>=TrafficLevThs), and the adjacent cell's level satisfies its minimum

Description

access level, handover can be performed to the adjacent cell.

Managed Object

Cell
0..48

Value Range and Step

Step: 1

Unit

None

Default Value

24

Default Value
Configuration Reason

If the target cell's level is not lower than the serving cell, traffic handover
can be performed to balance traffic. If this threshold is too high, it is
difficult to select a user for outgoing handover.
When the outgoing handover is prefered to be performed on the cell
with large traffic, the value should be adjusted as small. Otherwise,

Configuration Rule and


Adjustment Suggestion

the value should be adjusted as large. This threshold must be less


than the PBGT threshold in reverse direction. Otherwise, it may result
in toggle handover.
For the scenario with dense traffic, the value can be reduced properly.

Change Mode

Offline

Related features

ZGO-02-02-007 Traffic Based Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Arithmetic

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-879
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.9.6.2 Level offset during penalty (PenaltyLevOffset)


Full Name

Level offset during penalty

Abbreviation

PenaltyLevOffset

3GPP Name

Internal

3GPP Reference

None
When the MS is performing PS services, if the target cell is in the penalty
for handover failure, an offset is made on the downlink level of the target

Description

cell.

Managed Object

Cell
0..63

Value Range and Step

Step: 1

Unit

dB

Default Value

15

Default Value

Generally, the cell in penalty can be no longer ordered in the front of the

Configuration Reason

handover list if other adjacent cells with good signal are available.

Configuration Rule and

If many adjacent cells to which handover can be performed are available,

Adjustment Suggestion

the value should be large. Otherwise, the value should be small.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Arithmetic

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.6.3 Uplink interference quality offset (QOffSetUl)


Full Name

Uplink interference quality offset


5-880

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Abbreviation

QOffSetUl

3GPP Name

Internal

3GPP Reference

None
Value range 0..6 indicates the quality offset range is -3..3.
The MS is tuned to the predefined interference area due to the uplink
quality is poor and level is high when the MS performs PS services.
If AvRxQualUL(s)<InterfFQSS(s), uplink interference handover can be
performed.
Where, AvRxQualUL(s) is the average bit error rate (MEAN_BEP),
InterfFQSS(s) is the bit error rate threshold calculated by the average
uplink level AvRxLevUL(s). The calculation formula is as follows:
InterfFQSS(s)=0 if AvRxLevUL(s)<XOffset+20
=YOffset+9 if XOffset+20<=AvRxLevUL(s)<XOffset+30
=YOffset+9 if XOffset+20<=AvRxLevUL(s)<XOffset+30
=YOffset+5 if XOffset+40<=AvRxLevUL(s)
XOffset and YOffset respectively represent the uplink interference level

Description

offset and quality offset specified by cell paramters.

Managed Object

Cell
0..6

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Setting of the default value is in accordance with the general radio

Configuration Reason

environment.

Configuration Rule and


Adjustment Suggestion

The larger the value is, the lower is the quality tolerability under the
corresponding level, and it is easier to initiate quality handover which
should be adjusted in accordance with the actual network situation.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Arithmetic
5-881

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.6.4 Uplink interference level offset (SOffSetUl)


Full Name

Uplink interference level offset

Abbreviation

SOffSetUl

3GPP Name

Internal

3GPP Reference

None
Value range 0..20 indicates the quality offset range is -10..10 dB.
The MS is tuned to the predefined interference area due to the uplink
quality is poor and level is high when the MS performs PS services.
If AvRxQualUL(s) < InterfFQSS(s), uplink interference handover can be
performed.
Where, AvRxQualUL(s) is the average bit error rate (MEAN_BEP),
InterfFQSS(s) is the bit error rate threshold calculated by the average
uplink level AvRxLevUL(s). The calculation formula is as follows:
InterfFQSS(s)=0 if AvRxLevUL(s) <XOffset +20
=YOffset+9 if XOffset+20 <= AvRxLevUL(s) <XOffset +30
=YOffset+9 if XOffset+20 <= AvRxLevUL(s) <XOffset +30
=YOffset+5 if XOffset+40 <= AvRxLevUL(s)
XOffset and YOffset respectively represent the uplink interference level

Description

offset and quality offset specified by cell paramters.

Managed Object

Cell
0..20

Value Range and Step

Step: 1

Unit

dB

Default Value

15

Default Value

Setting of the default value is in accordance with the general radio

Configuration Reason

environment.

Configuration Rule and


Adjustment Suggestion

The larger the value is, the lower the requirement on quality handover is,
and it is easier to initiate quality handover which should be adjusted in
accordance with the actual network situation.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

5-882
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Arithmetic

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.6.5 Downlink interference quality offset (QOffSetDl)


Full Name

Downlink interference quality offset

Abbreviation

QOffSetDl

3GPP Name

Internal

3GPP Reference

None
Value range 0..6 indicates the quality offset range is -3..3.
The MS is tuned to the predefined interference area due to the uplink
quality is poor and level is high when the MS performs PS services.
If AvRxQualUL(s)<InterfFQSS(s), downlink interference handover can
be performed.
Where, AvRxQualUL(s) is the average downlink bit error rate
(MEAN_BEP), InterfFQSS(s) is the bit error rate threshold calculated by
the average downlink level AvRxLevUL(s). The calculation formula is
as follows:
InterfFQSS(s)=0 if AvRxLevUL(s)<XOffset+20
=YOffset+9 if XOffset+20<=AvRxLevUL(s)<XOffset+30
=YOffset+7 if XOffset+30<=AvRxLevDL(s)<XOffset+40
=YOffset+5 if XOffset+40<=AvRxLevUL(s)
XOffset and YOffset respectively represent the downlink interference

Description

level offset and quality offset specified by cell paramters.

Managed Object

Cell
0..6

Value Range and Step

Step: 1

Unit

None

5-883
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value

Setting of the default value is in accordance with the general radio

Configuration Reason

environment.

Configuration Rule and


Adjustment Suggestion

The larger the value is, the lower is the quality tolerability under the
corresponding level, and it is easier to initiate quality handover which
should be adjusted in accordance with the actual network situation.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control->Handover Arithmetic
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.6.6 Downlink interference level offset (SOffSetDl)


Full Name

Downlink interference level offset

Abbreviation

SOffSetDl

3GPP Name

Internal

3GPP Reference

None
Value range 0..20 indicates the quality offset range is -10..10 dB.
The MS is tuned to the predefined interference area due to the uplink
quality is poor and level is high when the MS performs PS services.
If AvRxQualUL(s)<InterfFQSS(s), downlink interference handover can
be performed.
Where, AvRxQualUL(s) is the average downlink bit error rate
(MEAN_BEP), InterfFQSS(s) is the bit error rate threshold calculated by
the average downlink level AvRxLevUL(s). The calculation formula is

Description

as follows:

5-884
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

InterfFQSS(s) = 0 if AvRxLevUL(s) <XOffset +20


= YOffset +9 if XOffset+20 <= AvRxLevUL(s) <XOffset +30
= YOffset +7 if XOffset+30 <= AvRxLevDL(s) <XOffset +40
= YOffset +5 if XOffset+40 <= AvRxLevUL(s)
XOffset and YOffset respectively represent the downlink interference
level offset and quality offset specified by cell paramters.
Managed Object

Cell
0..20

Value Range and Step

Step: 1

Unit

dB

Default Value

10

Default Value

Setting of the default value is in accordance with the general radio

Configuration Reason

environment.

Configuration Rule and


Adjustment Suggestion

The larger the value is, the lower the requirement on quality handover is,
and it is easier to initiate quality handover which should be adjusted in
accordance with the actual network situation.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Arithmetic

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.9.6.7 Invalid intra-handover time (TMaxiHo)


Full Name

Invalid intra-handover time

Abbreviation

TMaxiHo

5-885
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

Internal

3GPP Reference

None
PSWhen the MS performs PS services, the timer TMaxIHo starts after
the MS performs interference handover in the cell for the first time. If handover occurs again before the counter ecxpires, the previous handover
is considered to have no influence on interference, the counter HoCount
increases by 1 and the counter TMaxIHo restarts. If handover occurs after the counter expires, the previous handover is considered valid, clear
the counter IHoCount to 0 and restart the counter TMaxIHo.If the counter
reaches MaxIHo, it indicates that no more attempt is needed, and the in-

Description

ter-cell handover shoudl be performed.

Managed Object

Cell
1..100

Value Range and Step

Step: 1

Unit

Default Value

Default Value

If the handover occurs continuously within 3 seconds, it is considered

Configuration Reason

as too frequent.
If the default value is set as too small, the invalid handover is easily to

Configuration Rule and

be judged as valid handover.

Adjustment Suggestion

If the value is set as too large, the valid handover is easily to be judged
as invalid handover.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Arithmetic

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-886
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.9.6.8 MAX count of invalid intra-handover (MaxiHo)


Full Name

MAX count of invalid intra-handover

Abbreviation

MaxiHo

3GPP Name

Internal

3GPP Reference

None
PSWhen the MS performs PS services, the timer TMaxIHo starts after
the MS performs interference handover in the cell for the first time. If
handover occurs again before the counter expires, the previous handover
is considered to have no influence on interference, the counter HoCount
increases by 1 and the counter TMaxIHo restarts. If handover occurs after
the counter expires, the previous handover is considered valid, clear the
counter IHoCount to 0 and restart the counter TMaxIHo. If the counter
reaches MaxIHo, it indicates that no more attempt is needed, and the

Description

inter-cell handover should be performed.

Managed Object

Cell
1..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

Usually, if the handover occurs three times continuously, it is considered

Configuration Reason

as too frequent.
If the value is too small, the handover is easily to be judged as invalid

Configuration Rule and

and the MS is performed on penalty, which is likely to cause call drop.

Adjustment Suggestion

If the value is too large, the handover is difficult to be judged as invalid


interference handover and the number of invalid handover increases.

Change Mode

Offline

Related features

ZGO-02-02-016 PS Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->Site Config->Site ID->Cell ID->PS Handover


Control->Handover Arithmetic

5-887
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10 LTE Cell Control Parameters


5.10.1 Site Id (SiteId)
Full Name

Site Id

Abbreviation

SiteId

3GPP Name

None

3GPP Reference

None

Description

This parameter determines the site ID of the source cell.

Managed Object

Cell

Value Range and Step

0..65535

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

5-888
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.10.2 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None

Description

This parameter determines the ID of the source cell.

Managed Object

Cell

Value Range and Step

0..255

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-889
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.10.3 EUTRAN BTS ID (LTEBTSID)


Full Name

EUTRAN BTS ID

Abbreviation

LTEBTSID

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the LTE control ID of a cell.

Managed Object

Cell
1..24
OB06: 3
BS20: 3
BS21: 3
BS21V20: 3
BS30: 3
BS30V12: 3
B8112: 6
M8202: 6
M8206: 6
B8018: 6
S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

5-890
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10.4 QSearchC (QSearchC)


Full Name

QSearchC

Abbreviation

QSearchC

3GPP Name

None

3GPP Reference

None
RxLevel Threshold for Measure E-UTRAN Neighbour Cell In Dedicated

Description

Mode

Managed Object

CELL
0-15
0: below - 98dBm
1: below - 94dBm
2: below - 90dBm
3: below -86dBm
4: below -82dBm
5: below -78dBm
6: below -74dBm
7: always
8: above - 78dBm
9: above -74dBm
10: above -70dBm
11: above -66dBm
12: above -62dBm
13: above -58dBm
14: above -54dBm

Value Range and Step

15: never

Unit

dBm

Default Value

Default Value
Configuration Reason

In the special state, the UTRAN cell level is always measured.

Configuration Rule and


Adjustment Suggestion

Set this parameter as required by the actual conditions.

Change Mode

Offline

5-891
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.10.5 Initial parameter used before UE receiving qsearch_c


(QSearchCInit)
Full Name

Initial parameter used before UE receiving qsearch_c

Abbreviation

QSearchCInit

3GPP Name

Qsearch_C_E-UTRAN_Initial

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter indicates the parameter used before the QSearchC parameter is acquired. If the value of this parameter ranges from 0 to 7,
the system searches EUTRAN adjacent cells when the signal strength is
lower than that corresponding to the value. If the value of this parameter
ranges from 8 to 15, the system searches EUTRAN cells when the UE

Description

signal strength is higher than that corresponding to the value.

Managed Object

Cell
0..15
0..7: Field strength L= -98+n*4 dbm
7, : always
8..14: Field strength L= -78+4*(n-8)dbm

Value Range and Step

15, : never

Unit

dbm

Default Value

Default Value
Configuration Reason

None
5-892

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10.6 Class of reported quantities of E-UTRAN adjacent cells


(RepQuant)
Full Name

Class of reported quantities of E-UTRAN adjacent cells

Abbreviation

RepQuant

3GPP Name

E-UTRAN_REP_QUANT

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the type of LTE adjacent cells reported in the

Description

measurement report.

Managed Object

Cell
0..1

Value Range and Step

0 = RSRP, 1 = RSRQ

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline
5-893

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10.7 Max number of E-UTRAN adjacent cells in measurement


report (MulRatRrpt)
Full Name

Max number of E-UTRAN adjacent cells in measurement report

Abbreviation

MulRatRrpt

3GPP Name

E-UTRAN_MULTIRAT_REPORTING

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the maximum number of LTE adjacent cells
(GPRS) supported in the measurement report or the list of cells with the

Description

strongest signal strength.

Managed Object

Cell

Value Range and Step

0..3

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

5-894
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10.8 FDD Measurement report threshold of RSRP or RSRQ in


6-bit (FDDRptthresh)
Full Name

FDD Measurement report threshold of RSRP or RSRQ in 6-bit

Abbreviation

FDDRptthresh

3GPP Name

E-UTRAN_FDD_REPORTING_THRESHOLD

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the threshold for reporting RSRP or RSRQ
(specified in RepQuant) measurement reports when the type of FDD mea-

Description

surement report is 6-bit.

Managed Object

Cell
0..7
0: 6
1: 12
...
6: 36
7: (never)

Value Range and Step

0: always

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline
5-895

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10.9 FDD Measurement report threshold of RSRQ or RSRP in


6-bit reporting (FDDRptthresh2)
Full Name

FDD Measurement report threshold of RSRQ or RSRP in 6-bit reporting

Abbreviation

FDDRptthresh2

3GPP Name

E-UTRAN_FDD_REPORTING_THRESHOLD_2

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the threshold for reporting RSRP or RSRQ
(not specified in RepQuant) measurement reports when the type of FDD

Description

measurement report is 6-bit.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

0(disable)

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

5-896
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10.10 FDDRptOffset6bit (FDDRptOffset6bit)


Full Name

FDDRptOffset6bit

Abbreviation

FDDRptOffset6bit

3GPP Name

None

3GPP Reference

None
offset to the reported value when prioritising the FDD E-UTRAN cells for

Description

6bit reporting

Managed Object

CELL
0..7,means

Value Range and Step

0, 6, ... , 42dB.

Unit

dB

Default Value

Default Value
Configuration Reason

The Offset is normally not necessary.

Configuration Rule and


Adjustment Suggestion

Set this parameter according to the MR type and mode.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

0
5-897

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.10.11 FDDRptOffset3bit (FDDRptOffset3bit)


Full Name

FDDRptOffset3bit

Abbreviation

FDDRptOffset3bit

3GPP Name

None

3GPP Reference

None
offset to the reported value when prioritising the FDD E-UTRAN cells for

Description

3bit reporting

Managed Object

CELL
0..7,means

Value Range and Step

0, 6, ... , 42dB.

Unit

dB

Default Value

Default Value
Configuration Reason

The Offset is normally not necessary.

Configuration Rule and


Adjustment Suggestion

Set this parameter according to the MR type and mode.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-898
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.10.12 TDD Measurement report threshold of RSRP or RSRQ in


6-bit reporting (TDDRptthresh)
Full Name

TDD Measurement report threshold of RSRP or RSRQ in 6-bit reporting

Abbreviation

TDDRptthresh

3GPP Name

E-UTRAN_TDD_REPORTING_THRESHOLD

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the threshold for reporting RSRP or RSRQ
(not specified in RepQuant) measurement reports when the type of TDD

Description

measurement report is 6-bit.

Managed Object

Cell
0..7
0: 6
1: 12
...
6: 36
7: (never)

Value Range and Step

0: always

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

0
5-899

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10.13 TDD Measurement report threshold of RSRQ or RSRP in


6-bit reporting (TDDRptthresh2)
Full Name

TDD Measurement report threshold of RSRQ or RSRP in 6-bit reporting

Abbreviation

TDDRptthresh2

3GPP Name

E-UTRAN_TDD_REPORTING_THRESHOLD_2

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the threshold for reporting RSRP or RSRQ
(not specified in RepQuant) measurement reports when the type of TDD

Description

measurement report is 6-bit.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

0(disable)

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

5-900
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10.14 TDDRptOffset6bit (TDDRptOffset6bit)


Full Name

TDDRptOffset6bit

Abbreviation

TDDRptOffset6bit

3GPP Name

None

3GPP Reference

None
offset to the reported value when prioritising the TDD E-UTRAN cells for

Description

6bit reporting

Managed Object

CELL
0..7,means

Value Range and Step

0, 6, ... , 42dB.

Unit

dB

Default Value

Default Value
Configuration Reason

The Offset is normally not necessary.

Configuration Rule and


Adjustment Suggestion

Set this parameter according to the MR type and mode.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID->LTE Cell Control

5-901
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.10.15 TDDRptOffset3bit (TDDRptOffset3bit)


Full Name

TDDRptOffset3bit

Abbreviation

TDDRptOffset3bit

3GPP Name

None

3GPP Reference

None
offset to the reported value when prioritising the TDD E-UTRAN cells for

Description

3bit reporting

Managed Object

CELL
0..7,means

Value Range and Step

0, 6, ... , 42dB.

Unit

dB

Default Value

Default Value
Configuration Reason

The Offset is normally not necessary.

Configuration Rule and


Adjustment Suggestion

Set this parameter according to the MR type and mode.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

iBSCV6.20.712a

5-902
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

New

5.10.16 FDD Measurement report threshold of RSRP or RSRQ in


3-bit reporting (FDDMeasRptOffset)
Full Name

FDD Measurement report threshold of RSRP or RSRQ in 3-bit reporting

Abbreviation

FDDMeasRptOffset

3GPP Name

E-UTRAN_FDD_MEASUREMENT_REPORT_OFFSET

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the calculated mapping value of RSRP or
RSRQ (specified in RepQuant) parameters when the type of FDD mea-

Description

surement report is 3-bit.

Managed Object

Cell
For RSRP the mapping is as follows:
0 = -140 dBm, 1 = -139 dBm, 2 = -138 dBm, ..., 62 = -78 dBm, 63 =
-77 dBm.
For RSRQ the mapping is as follows:

Value Range and Step

0 = -19.5 dB, 1 = -19 dB, 2 = -18.5 dB, ..., 29 = -4 dB, 30 = -3.5 dB.

Unit

dBm/dB

Default Value

Default Value
Configuration Reason

It is required to configure this parameter according to the protocol.

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

5-903
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10.17 FDD Measurement report threshold of RSRQ or RSRP in


3-bit reporting (FDDMeasRptthresh2)
Full Name

FDD Measurement report threshold of RSRQ or RSRP in 3-bit reporting

Abbreviation

FDDMeasRptthresh2

3GPP Name

E-UTRAN_FDD_REPORTING_THRESHOLD_2

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the threshold for reporting RSRP or RSRQ
(not specified in RepQuant) measurement reports when the type of FDD

Description

measurement report is 3-bit.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

0(disable)

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

5-904
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.10.18 TDD Measurement report threshold of RSRP or RSRQ in


3-bit reporting (TDDMeasRptOffset)
Full Name

TDD Measurement report threshold of RSRP or RSRQ in 3-bit reporting

Abbreviation

TDDMeasRptOffset

3GPP Name

E-UTRAN_TDD_MEASUREMENT_REPORT_OFFSET

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the offset value in RSRP or RSRQ (specified
in RepQuant) measurement reports when the type of TDD measurement

Description

report is 3-bit.

Managed Object

Cell
For RSRP the mapping is as follows:
0 = -140 dBm, 1 = -139 dBm, 2 = -138 dBm, ..., 62 = -78 dBm, 63 =
-77 dBm.
For RSRQ the mapping is as follows:

Value Range and Step

0 = -19.5 dB, 1 = -19 dB, 2 = -18.5 dB, ..., 29 = -4 dB, 30 = -3.5 dB.

Unit

dBm/dB

Default Value

Default Value
Configuration Reason

It is required to configure this parameter according to the protocol.

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

5-905
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10.19 TDD Measurement report threshold of RSRQ or RSRP in


3-bit reporting (TDDMeasRptthresh2)
Full Name

TDD Measurement report threshold of RSRQ or RSRP in 3-bit reporting

Abbreviation

TDDMeasRptthresh2

3GPP Name

E-UTRAN_TDD_REPORTING_THRESHOLD_2

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the threshold for reporting RSRP or RSRQ
(not specified in RepQuant) measurement reports when the type of TDD

Description

measurement report is 3-bit.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

0(disable)

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

5-906
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.10.20 Measurement report threshold offset of RSRQ or RSRP in


3-bit reporting (RptGranularity)
Full Name

Measurement report threshold offset of RSRQ or RSRP in 3-bit reporting

Abbreviation

RptGranularity

3GPP Name

REPORTING_GRANULARITY

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the offset value in RSRP or RSRQ measure-

Description

ment reports when the type of measurement report is 3-bit.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

dB

Default Value

Default Value
Configuration Reason

It is required to configure this parameter according to the protocol.

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-907
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.10.21 Measurement threshold of UE performing GPRS E-UTRAN


Cell (QsearchP_PS)
Full Name

Measurement threshold of UE performing GPRS E-UTRAN Cell

Abbreviation

QsearchP_PS

3GPP Name

Qsearch_P_E-UTRAN

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the threshold used when the UE starts measurement on reselection of a GPRS LTE cell. If the value of this parameter
ranges from 0 to 7, the system searches EUTRAN adjacent cells when the
signal strength is lower than that corresponding to the value. If the value
of this parameter ranges from 8 to 15, the system searches EUTRAN
cells when the UE signal strength is higher than that corresponding to the

Description

value.

Managed Object

Cell
0..15
0.7: Field strength L= -98+n*4 dbm
7, : always
8..14: Field strength L= -78+4*(n-8)dbm

Value Range and Step

15, : never

Unit

dbm

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None
5-908

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Parameter Modifying
Detail

None

5.10.22 GPRS max number of E-UTRAN adjacent cells in


measurement report (MulRatRpt_PS)
Full Name

GPRS max number of E-UTRAN adjacent cells in measurement report

Abbreviation

MulRatRpt_PS

3GPP Name

E-UTRAN_REP_QUANT

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the maximum number of GPRS LTE adjacent cells supported in the measurement report or the list of cells with

Description

the strongest signal strength.

Managed Object

Cell

Value Range and Step

0..3

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-909
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.10.23 GPRS class of reported quantities of E-UTRAN adjacent


cells (RepQuant_PS)
Full Name

GPRS class of reported quantities of E-UTRAN adjacent cells

Abbreviation

RepQuant_PS

3GPP Name

E-UTRAN_MULTIRAT_REPORTING

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the type of GPRS LTE adjacent cells in the

Description

measurement report.

Managed Object

Cell
0..1

Value Range and Step

0 = RSRP, 1 = RSRQ

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-910
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.10.24 GPRS FDD Measurement report threshold of RSRP or


RSRQ (FDDRptThresh_PS)
Full Name

GPRS FDD Measurement report threshold of RSRP or RSRQ

Abbreviation

FDDRptThresh_PS

3GPP Name

E-UTRAN_FDD_REPORTING_THRESHOLD

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the threshold for reporting GPRS RSRP or
RSRQ (specified in RepQuant) measurement reports when the type of

Description

FDD measurement report is 6-bit.

Managed Object

Cell
0..7
0: 6
1: 12
...
6: 36
7: (never)

Value Range and Step

0: always

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None
5-911

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

5.10.25 GPRS FDD Measurement report threshold of RSRQ or


RSRP (FDDRptThresh2_PS)
Full Name

GPRS FDD Measurement report threshold of RSRQ or RSRP

Abbreviation

FDDRptThresh2_PS

3GPP Name

E-UTRAN_FDD_REPORTING_THRESHOLD_2

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the threshold for reporting GPRS RSRP or
RSRQ (not specified in RepQuant) measurement reports when the type

Description

of FDD measurement report is 6-bit.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

0(disable)

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10.26 FDDRptOffset_PS (FDDRptOffset_PS)


Full Name

FDDRptOffset_PS

5-912
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Abbreviation

FDDRptOffset_PS

3GPP Name

None

3GPP Reference

None
offset to the reported value when prioritising the FDD E-UTRAN cells for

Description

PS

Managed Object

CELL
0..7,means

Value Range and Step

0, 6, ... , 42dB.

Unit

dB

Default Value

Default Value
Configuration Reason

The Offset is normally not necessary.

Configuration Rule and


Adjustment Suggestion

Set this parameter according to the MR type and mode.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.10.27 GPRS TDD Measurement report threshold of RSRP or


RSRQ (TDDRptThresh_PS)
Full Name

GPRS TDD Measurement report threshold of RSRP or RSRQ

Abbreviation

TDDRptThresh_PS

3GPP Name

E-UTRAN_TDD_REPORTING_THRESHOLD
5-913

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the threshold for reporting GPRS RSRP or
RSRQ (not specified in RepQuant) measurement reports when the type

Description

of TDD measurement report is 6-bit.

Managed Object

Cell
0..7
0: 6
1: 12
...
6: 36
7: (never)

Value Range and Step

0: always

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10.28 GPRS TDD Measurement report threshold of RSRQ or


RSRP (TDDRptThresh2_PS)
Full Name

GPRS TDD Measurement report threshold of RSRQ or RSRP


5-914

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Abbreviation

TDDRptThresh2_PS

3GPP Name

E-UTRAN_TDD_REPORTING_THRESHOLD_2

3GPP Reference

3GPP TS 44018 V8.9.0


This parameter determines the threshold for reporting GPRS RSRP or
RSRQ (not specified in RepQuant) measurement reports when the type

Description

of TDD measurement report is 6-bit.

Managed Object

Cell

Value Range and Step

0..63

Unit

None

Default Value

0(disable)

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.10.29 TDDRptOffset_PS (TDDRptOffset_PS)


Full Name

TDDRptOffset_PS

Abbreviation

TDDRptOffset_PS

3GPP Name

None

3GPP Reference

None

5-915
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

offset to the reported value when prioritising the TDD E-UTRAN cells for
Description

PS

Managed Object

CELL
0..7,means

Value Range and Step

0, 6, ... , 42dB.

Unit

dB

Default Value

Default Value
Configuration Reason

The Offset is normally not necessary.

Configuration Rule and


Adjustment Suggestion

Set this parameter according to the MR type and mode.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.10.30 WindowEutran (WindowEutran)


Full Name

WindowEutran

Abbreviation

WindowEutran

3GPP Name

None

3GPP Reference

None
Sliding window size for calculating average value of E-Utran Neighbour

Description

Cell

Managed Object

CELL

5-916
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Value Range and Step

1..20

Unit

None

Default Value

Default Value
Configuration Reason

The protocol specified the default value.

Configuration Rule and


Adjustment Suggestion

The greater the parameter value, the longer the measurement time.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->Site config->Site ID->Cell ID->LTE Cell Control

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

5.11 LTE Cell Reselection Parameters


5.11.1 User label (UserLabel)
Full Name

User label

Abbreviation

UserLabel

3GPP Name

None

3GPP Reference

None

Description

This parameter facilitates subscribers to identify a cell name.

Managed Object

Cell

Value Range and Step

A string with 40 characters at most

Unit

None

5-917
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.2 SITE ID (SITEID)


Full Name

SITE ID

Abbreviation

SITEID

3GPP Name

None

3GPP Reference

None
This parameter indicates the ID of this BTS, which cannot be modified.

Description

It is the same as the ID of an SDR management NE.

Managed Object

Site

Value Range and Step

1..1536

Unit

None

Default Value

Default Value
Configuration Reason

None

5-918
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.3 BTS ID (BTSID)


Full Name

BTS ID

Abbreviation

BTSID

3GPP Name

None

3GPP Reference

None
This parameter indicates the ID of this cell, which cannot be modified.

Description

It is the same as the ID of SDR sector.

Managed Object

Cell
1..24
OB06: 3
BS20: 3
BS21: 3
BS21V20: 3
BS30: 3
BS30V12: 3
B8112: 6
M8202: 6

Value Range and Step

M8206: 6
5-919

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

B8018: 6
S8001: 1
SDR: 24
Unit

None

Default Value

according to the real number

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.4 LTE Cell reselect Identification (LTERSID)


Full Name

LTE Cell reselect Identification

Abbreviation

LTERSID

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the reselection ID of an LTE cell.

Managed Object

Cell

Value Range and Step

1..64

Unit

None

Default Value

None
5-920

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.5 The priority of E-UTRAN cells (ArfcnLTEPrio)


Full Name

The priority of E-UTRAN cells

Abbreviation

ArfcnLTEPrio

3GPP Name

E-UTRAN_PRIORITY

3GPP Reference

3GPP TS 44018 V8.9.0

Description

This parameter determines the priority of an EUTRAN cell.

Managed Object

Cell
0..7
0: lowest;

Value Range and Step

7: highest

Unit

None

Default Value

equal to EUtranDefaultPrio

Default Value
Configuration Reason

None

5-921
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.6 CCN mode support (CCNSUPPORT)


Full Name

CCN mode support

Abbreviation

CCNSUPPORT

3GPP Name

None

3GPP Reference

None

Description

This parameter determines whether this cell supports the CNN function.

Managed Object

Cell
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None
5-922

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.7 The re-selecting flag of LTE Ncell (NCelBlackListInd)


Full Name

The re-selecting flag of LTE Ncell

Abbreviation

NCelBlackListInd

3GPP Name

None

3GPP Reference

None
This parameter determines whether an MS can be reselected to this ad-

Description

jacent cell.

Managed Object

Cell
0: allowed to re-select

Value Range and Step

1: not allowed ot re-select

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None
5-923

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.8 MCC (MCC)


Full Name

MCC

Abbreviation

MCC

3GPP Name

None

3GPP Reference

None
The Mobile Country Code (MCC) consists of three decimal digits. It
uniquely identifies the country to which a mobile subscriber (or system)

Description

belongs.

Managed Object

Cell

Value Range and Step

None

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
5-924

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.9 MNC (MNC)


Full Name

MNC

Abbreviation

MNC

3GPP Name

None

3GPP Reference

None
A Mobile Network Code (MNC) consists of three decimal digits and is
used to uniquely identify a specific GSM PLMN in a country (depending

Description

on MCC).

Managed Object

Cell

Value Range and Step

None

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

5-925
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.10 LTE CELL Identification (ENBID)


Full Name

LTE CELL Identification

Abbreviation

ENBID

3GPP Name

None

3GPP Reference

None

Description

This parameter determines the ID of an LTE cell.

Managed Object

Cell
when ENBInd = 0, the range is 0~1048575

Value Range and Step

when ENBInd = 1, the range is 0~0xFFFFFFF

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None
5-926

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

5.11.11 LTE CELL TYPE (CellTypeLTE)


Full Name

LTE CELL TYPE

Abbreviation

CellTypeLTE

3GPP Name

None

3GPP Reference

None
This parameter determines the type of an LTE cell, including FDD and

Description

TDD.

Managed Object

Cell
0..1
0: FDD

Value Range and Step

1: TDD

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.12 Tracking area code (TAC)


Full Name

Tracking area code


5-927

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

TAC

3GPP Name

None

3GPP Reference

None

Description

This parameter determines the ID of a trace cell.

Managed Object

Cell

Value Range and Step

0..65535

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.13 Physical layer cell identity of LTE CELL (PCID)


Full Name

Physical layer cell identity of LTE CELL

Abbreviation

PCID

3GPP Name

PCID

3GPP Reference

3GPP TS 44018 V8.9.0

Description

This parameter determines the physical ID of an LTE cell.

5-928
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Managed Object

Cell

Value Range and Step

0..503

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.14 The attribute of LTE NodeB (ENBInd)


Full Name

The attribute of LTE NodeB

Abbreviation

ENBInd

3GPP Name

None

3GPP Reference

None

Description

This parameter determines the attribute of an LTE NodeB.

Managed Object

Cell
0..1
0: Macro eNB

Value Range and Step

1: Home eNB

Unit

None
5-929

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.15 Specified EARFCN of E-UTRAN cells (ArfcnLTE)


Full Name

Specified EARFCN of E-UTRAN cells

Abbreviation

ArfcnLTE

3GPP Name

EARFCN

3GPP Reference

3GPP TS 44018 V8.9.0

Description

This parameter determines the frequency of an adjacent LTE cell.

Managed Object

Cell

Value Range and Step

0..65535

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.
5-930

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.16 the minimum value of the channel bandwidth


(MeasureBandwidth)
Full Name

the minimum value of the channel bandwidth

Abbreviation

MeasureBandwidth

3GPP Name

None

3GPP Reference

None
This parameter determines the minimum bandwidth for the channel of an

Description

adjacent LTE cell.

Managed Object

Cell
0..7
0: NRB = 6
1: NRB = 15
2: NRB = 25
3: NRB = 50
4: NRB = 75
5: NRB = 100

Value Range and Step

6-7: reserved

Unit

None

Default Value

5-931
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

None

Configuration Rule and

It is required to configure this parameter according to actual network

Adjustment Suggestion

configuration.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.11.17 Related Cell DN (RelationDN)


Full Name

Related Cell DN

Abbreviation

RelationDN

3GPP Name

None

3GPP Reference

None
A user can click <Select> to select a cell or an external cell on the displayed interface. Then, select the <mutual configuration> check box to

Description

mutually configure it as a reselection and handover cell.

Managed Object

Cell

Value Range and Step

None

Unit

None

Default Value

None

Default Value
Configuration Reason

None

5-932
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Configuration Rule and


Adjustment Suggestion

It is a fixed value and thus requires no modification.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Cell ID->LTE Cell


Reselection

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.12 VPC Cell Parameters


5.12.1 User label (UserLabel)
Full Name

User label

Abbreviation

UserLabel

3GPP Name

None

3GPP Reference

None

Description

This parameter facilitates subscribers to identify a cell name.

Managed Object

Cell

Value Range and Step

A string with 40 characters at most

Unit

None

Default Value

None

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

5-933
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Set VPC Cell

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.12.2 Site identifier (SiteId)


Full Name

Site identifier

Abbreviation

SiteId

3GPP Name

None

3GPP Reference

None
This parameter indicates the station ID of the cell to which a VPC cell

Description

belongs.

Managed Object

Cell

Value Range and Step

1..1536

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

The cell represented by SiteId or BtsId should exist in the R_BTS table.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

5-934
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Set VPC Cell

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

None

5.12.3 BTS ID (BtsId)


Full Name

BTS ID

Abbreviation

BtsId

3GPP Name

None

3GPP Reference

None
This parameter indicates the intra-station ID of the cell to which a VPC

Description

cell belongs.

Managed Object

Cell
1..24
OB06: 3
BS20: 3
BS21: 3
BS21V20: 3
BS30: 3
BS30V12: 3
B8112: 6
M8202: 6
M8206: 6
B8018: 6
S8001: 1

Value Range and Step

SDR: 24

Unit

None

Default Value

None

Default Value
Configuration Reason

None

5-935
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

The cell represented by SiteId or BtsId should exist in the R_BTS table.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Set VPC Cell

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

None

5.12.4 Vpc Identity (VpcId)


Full Name

Vpc Identity

Abbreviation

VpcId

3GPP Name

None

3GPP Reference

None
This parameter indicates the ID of a VPC cell. It is used to distinguish

Description

multiple VPC cells that belong to a same cell.

Managed Object

Cell

Value Range and Step

1..128

Unit

None

Default Value

None

Default Value
Configuration Reason

None
The cell represented by VpcSiteId or VpcBtsId should exist in the R_BTS

Configuration Rule and

table.

Adjustment Suggestion

The IDs for the VPC cells (VpcSiteId or VpcBtsId) in a same cell cannot
be repeated.

Change Mode

Offline
5-936

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Set VPC Cell

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

None

5.12.5 Vpc Site Identity (VpcSiteId)


Full Name

Vpc Site Identity

Abbreviation

VpcSiteId

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the station ID of a VPC cell.

Managed Object

Cell

Value Range and Step

1..1536

Unit

None

Default Value

Default Value
Configuration Reason

None
The cell represented by VpcSiteId or VpcBtsId should exist in the R_BTS

Configuration Rule and

table.

Adjustment Suggestion

The IDs for the VPC cells (VpcSiteId or VpcBtsId) in a same cell cannot
be repeated.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

5-937
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Cell ID->Set VPC Cell

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

None

5.12.6 Vpc Bts Identity (VpcBtsId)


Full Name

Vpc Bts Identity

Abbreviation

VpcBtsId

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates the intra-station ID of a VPC cell.

Managed Object

Cell

Value Range and Step

1..108

Unit

None

Default Value

Default Value
Configuration Reason

None
The cell represented by VpcSiteId or VpcBtsId should exist in the R_BTS

Configuration Rule and

table.

Adjustment Suggestion

The IDs for the VPC cells (VpcSiteId or VpcBtsId) in a same cell cannot
be repeated.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

5-938
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Negotiation With CN
OMC Access Path

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config Set
ID->BSC Function ID->Site Config->Site ID->Cell ID->Set VPC Cell

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

None

5.13 Site Parameters


5.13.1 Inter subcell handover permitted (SUBCELLHO)
Full Name

Inter subcell handover permitted

Abbreviation

SUBCELLHO

3GPP Name

Internal

3GPP Reference

None
This parameter indicates which inter-subcell handover mode is supported.
Three handover modes are optional. Mode 1: If the MS is in subcell 2
of the source cell before the handover, it is handed over to subcell 2 of
the target cell in preference. If the MS is in subcell 1 of the source cell
before the handover, it can only be handed over to subcell 1 of the target
cell. Mode 2: No matter which subcell the MS is camped on before the
handover, it can only be handed over to subcell 1 of the target cell. Mode
3: Whether the MS can be directly handed over to subcell 2 depends on
the level measurement of the target cell. If the path loss of the target cell
is less than PathLossMin configured for the target cell, the MS is handed
over to subcell 2 in preference. Or else, the MS can only be handed over

Description

to subcell 1 of the target cell.

Managed Object

Site

Value Range and Step

Yes, No, Depend on radio measurement

Unit

None

Default Value

Yes

Default Value

In most cases, subcells of the same site have almost the same coverage

Configuration Reason

radius. The MS can be directly handed over between these subcells.

5-939
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Set the parameter value to "Yes" when the subcells of the site have
similar coverage radius to allow the handover from subcell 2 of the
source cell to subcell 2 of the target cell. If the coverage radius of
the target subcell 2 is greatly different from that of the source subcell
2, especially in the case of SDR multi-antenna transmission, set the
Configuration Rule and
Adjustment Suggestion

parameter to "Depend on radio measurement". When the coverage


radius of the cell is large, the handover condition must fulfill the criteria
of TA. In this case, the radio measurement mode is improper because
TA of the target cell cannot be measured during inter-cell handover.
Set the parameter to "No" to limit the handover to subcell 1 of the target
cell if the previous two modes are inappropriate, or these two modes
cause poor performance such as low handover success rate and high
call drop rate.

Change Mode

Offline

Related features

ZGO-05-02-009 Concentric Circle Technology

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.13.2 Baseband resource share support (BaseBandShare)


Full Name

Baseband resource share support

Abbreviation

BaseBandShare

3GPP Name

None

3GPP Reference

None

Description

This parameter is a site level switch for sharing of baseband resources.

Managed Object

Site

5-940
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

1: Yes
Value Range and Step

0: No

Unit

None

Default Value

0: No

Default Value
Configuration Reason

This parameter is a feature switch. By default, this switch is turned off.

Configuration Rule and

This switch can be enabled for tidal traffic as required by telecom

Adjustment Suggestion

operators.

Change Mode

Offline

Related features

ZGO-03-04-005 Baseband Resource Dynamic Sharing

Related Parameters

[BSC]BaseBandShare

Relationship

Site and BSC level switch

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->Site Config->Site ID->Basic Property

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.13.3 Traffic threshold for baseband allocation (BBURequestTR


AThs)
Full Name

Traffic threshold for baseband allocation

Abbreviation

BBURequestTRAThs

3GPP Name

None

3GPP Reference

None
This parameter is the traffic threshold for allocating baseband resources.
When the traffic in a cell is higher than the threshold, the BSC selects

Description

appropriate TRXs and allocates more baseband resources to the cell.

Managed Object

Site

Value Range and Step

0..100

5-941
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

Default Value

70

Default Value

The TRX selection and baseband resource allocation is initiated when

Configuration Reason

the traffic in a cell is heavy.


If this threshold is set to a too high value, baseband resource allocation

Configuration Rule and

is delayed in the case of heavy traffic and traffic congestion may occur in

Adjustment Suggestion

the cell. If this threshold is set to a too low value, too many baseband
resources are occupied by the cell when the cell is idle.

Change Mode

Offline

Related features

ZGO-03-04-005 Baseband Resource Dynamic Sharing

Related Parameters

[Site]BBUReleaseTRAThs

Relationship

BBURequestTRAThs > BBUReleaseTRAThs

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Baseband sharing


configuration

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.13.4 Traffic threshold for baseband release (BBUReleaseTRAThs)


Full Name

Traffic threshold for baseband release

Abbreviation

BBUReleaseTRAThs

3GPP Name

None

3GPP Reference

None
This parameter is the traffic threshold for releasing baseband resources.
When the traffic in a cell is lower than the threshold, the BSC selects

Description

appropriate TRXs and releases baseband resources from the cell.

Managed Object

Site

Value Range and Step

0..100

Unit

%
5-942

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

Default Value
Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

0
The traffic threshold 0 indicates that no baseband resource is released
even when the cell is idle. The purpose of setting the threshold to 0 is to
ensure that there are available baseband resources in the cell.
If this threshold is set to a too high value, baseband resources are
released when the cell is still busy. If this threshold is set to a too low
value, no baseband resource is released when the cell is idle.

Change Mode

Offline

Related features

ZGO-03-04-005 Baseband Resource Dynamic Sharing

Related Parameters

[Site]BBURequestTRAThs

Relationship

BBURequestTRAThs > BBUReleaseTRAThs

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Baseband sharing


configuration

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.13.5 Channel busy threshold for urgent allocate baseband


(BBUOVERThs)
Full Name

Channel busy threshold for urgent allocate baseband

Abbreviation

BBUOVERThs

3GPP Name

None

3GPP Reference

None
This parameter is the radio channel occupation rate threshold for emergency baseband resource allocation. When the radio channel occupation rate in a cell increases and becomes higher than the threshold due to
sudden increase in traffic, the BSC selects appropriate TRXs and allocate

Description

more baseband resources to the cell.

Managed Object

Site

5-943
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Value Range and Step

0..100

Unit

Default Value

80

Default Value

The BSC selects appropriate TRXs and allocates baseband resources

Configuration Reason

immediately when the channel occupation rate is high in a cell.


If this threshold is set to a too high value, baseband resource allocation

Configuration Rule and

is delayed in the case of heavy traffic and traffic congestion may occur in

Adjustment Suggestion

the cell. If this threshold is set to a too low value, too many baseband
resources are occupied by the cell when the cell is idle.

Change Mode

Offline

Related features

ZGO-03-04-005 Baseband Resource Dynamic Sharing

Related Parameters

[Site]BBULOWERThs

Relationship

BBUOVERThs > BBULOWERThs

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Baseband sharing


configuration

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5.13.6 Channel busy threshold for urgent release baseband


(BBULOWERThs)
Full Name

Channel busy threshold for urgent release baseband

Abbreviation

BBULOWERThs

3GPP Name

None

3GPP Reference

None

5-944
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 5 Cell Object Parameters

This parameter is the radio channel occupation rate threshold for releasing baseband resource allocation. When the baseband resource allocation request of a cell fails, the BSC searches for cells with radio channel
occupation rate lower than the threshold. If a cell with lower radio channel occupation rate is detected, the BSC selects appropriate TRXs and
Description

release baseband resources from the cell.

Managed Object

Site

Value Range and Step

0..100

Unit

Default Value

60

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default threshold prevents baseband resource release in busy cells.


Higher this threshold is set, more cells can be selected to release
baseband resources. Lower this threshold is set, less cells can be
selected to release baseband resources.

Change Mode

Offline

Related features

ZGO-03-04-005 Baseband Resource Dynamic Sharing

Related Parameters

[Site]BBUOVERThs

Relationship

BBUOVERThs > BBULOWERThs

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->Site Config->Site ID->Baseband sharing


configuration

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

5-945
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This page intentionally left blank.

5-946
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6

System Control Parameters


Table of Contents
Operation Control Parameters....................................................................................6-1
FUC Parameters ......................................................................................................6-62
Exchange Parameters of BCCH ...............................................................................6-72
Exchange Parameters of SD ....................................................................................6-80
Other Parameters.....................................................................................................6-87
IBS Parameters...................................................................................................... 6-119
Performance Management Parameters ..................................................................6-120
Baseband Frequency Hopping TRX Exchange Parameters....................................6-128
GPRS Operation Control Parameters .....................................................................6-133

6.1 Operation Control Parameters


6.1.1 User Label
Full Name

User Label

Abbreviation

UserLabel

3GPP Name

None

3GPP Reference

None

Description

System control name that is easily recognized by a user.

Managed Object

BSC

Value Range and


Step

Character string with the maximum length of 40.

Unit

None

Default Value

None

Default Value
Configuration
Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

6-1
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->System Control Parameters->Operation Control

OMC Access Path

Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.2 BSC ID
Full Name

BSC ID

Abbreviation

BSCID

3GPP Name

None

3GPP Reference

None

Description
Managed Object
Value Range and
Step

BSC ID cannot be modified. By default, the value is the same with that
of subnetwork ID.
BSC
1 ~ 4095

Unit

None

Default Value

None

Default Value
Configuration
Reason

None

Configuration Rule
and Adjustment
Suggestion

None

Change Mode

Offline

Related Features

None

6-2
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

None

Impact on service

None

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set
ID->BSC Function ID->System Control Parameters->Operation Control

OMC Access Path

Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.3 Assign queue enable (AssQueEnable)


Full Name

Assign queue enable

Abbreviation

AssQueEnable

3GPP Name

None

3GPP Reference

None
This parameter decides whether to allow an assignment to queue when

Description

it fails to request a channel.

Managed Object

BSC
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

1: Yes

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The default value is Yes in system control parameters. Generally, it


is required to modify only the related cell parameters and eMLPP
parameters.
The default value is Yes in system control parameters. Generally, it
is required to modify only the related cell parameters and eMLPP
parameters to control the level of the cell and the BSC.

Change Mode

Offline

Related features

ZGB-03-01-003 Queuing

6-3
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Parameters

[Cell]QueueInd_0
[BSC]QueueIndAss
This parameter is enabled only when the switches in cell parameters,

Relationship

eMLPP parameters, and BSC system control parameters are all set
to Yes.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

YES
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.4 Internal redirection enable (InDrEnable)


Full Name

Internal redirection enable

Abbreviation

InDrEnable

3GPP Name

None

3GPP Reference

None
This parameter decides whether to allow an assignment to request a
channel from other cells in the BSC when the assignment fails to request

Description

a channel.

Managed Object

BSC
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

1: Yes

Default Value
Configuration Reason

The default value is Yes in system control parameters. Generally, it is


required to modify only the related cell parameters to control the level
of the cell.

6-4
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

This function should be enabled to reduce network congestion and


uneven radio resource allocation and increase the call completion
rate when a cell is fluctuantly congested and its neighboring cells
Configuration Rule and

have available service channels. However, enabling the function will

Adjustment Suggestion

increase access delay and negatively affect user satisfaction. In a


heavily-congested network, enabling the function does not work. In this
case, capacity expansion and traffic balancing are much better ways to
relieve network congestion.

Change Mode

Offline

Related features

ZGB-03-01-002 Directed Retry

Related Parameters

[Cell]DrInd_0

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.5 Outer redirection enable (OutDrEnable)


Full Name

Outer redirection enable

Abbreviation

OutDrEnable

3GPP Name

None

3GPP Reference

None
This parameter decides whether to allow an assignment to request a
channel from the cells outside the BSC when the assignment fails to re-

Description

quest a channel.

Managed Object

BSC
1: Yes

Value Range and Step

0: No

Unit

None

6-5
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value

0: No

Default Value

Generally, this function is disabled because it relates to handovers

Configuration Reason

outside the MSC.


This function should be enabled to reduce network congestion and
uneven radio resource allocation and increase the call completion
rate when a cell is fluctuantly congested and its neighboring cells

Configuration Rule and

have available service channels. However, enabling the function will

Adjustment Suggestion

increase access delay and negatively affect user satisfaction. In a


heavily-congested network, enabling the function does not work. In this
case, capacity expansion and traffic balancing are much better ways to
relieve network congestion.

Change Mode

Offline

Related features

ZGB-03-01-002 Directed Retry

Related Parameters

[Cell]DrInd_1

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

YES

OMC Access Path

Set ID->BSC Function->System Control Parameter->Operation Control

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.6 Assign preemption enable (AssPreEmpt)


Full Name

Assign preemption enable

Abbreviation

AssPreEmpt

3GPP Name

None

3GPP Reference

None
This parameter decides whether to allow an assignment to forcedly release a channel occupied by a low-priority user when the assignment fails

Description

to request a channel.

Managed Object

BSC

6-6
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

1: Yes
Value Range and Step

0: No

Unit

None

Default Value

1: Yes

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The default value is Yes in system control parameters. Generally, it


is required to modify only the related cell parameters and eMLPP
parameters.
The default value is Yes in system control parameters. Generally, it
is required to modify only the related cell parameters and eMLPP
parameters to control the level of the cell and the BSC.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]PreemptionInd_0
[BSC]PreemptionIndAss

Relationship

This function cannot be enabled unless the switches in the BSC-level


and cell-level parameters are all set to Yes.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.7 BSC intracell handover enable (HoIntraEnable)


Full Name

BSC intracell handover enable

Abbreviation

HoIntraEnable

3GPP Name

None

3GPP Reference

None

Description

This parameter decides whether to allow BSC intra-cell handovers.

Managed Object

BSC

6-7
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

1: Yes
Value Range and Step

0: No

Unit

None

Default Value

1: Yes

Default Value
Configuration Reason

Handover is a basic function.

Configuration Rule and

The default value is recommended. Generally, intra-cell handovers are

Adjustment Suggestion

not controlled.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.8 BSC cell handover enable (HoInterEnable)


Full Name

BSC cell handover enable

Abbreviation

HoInterEnable

3GPP Name

None

3GPP Reference

None

Description

This parameter decides whether to allow BSC inter-cell handovers.

Managed Object

BSC

Value Range and Step

Yes/No

Unit

None

Default Value

1: Yes

6-8
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Default Value
Configuration Reason

Handover is a basic function.

Configuration Rule and

The default value is recommended. Generally, inter-BSC cell handovers

Adjustment Suggestion

are not controlled.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.9 BSC outer handover enable (HoOutEnable)


Full Name

BSC outer handover enable

Abbreviation

HoOutEnable

3GPP Name

None

3GPP Reference

None

Description

This parameter decides whether to allow outer-BSC handovers.

Managed Object

BSC
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

1: Yes

Default Value
Configuration Reason

Handover is a basic function.

Configuration Rule and

The default value is recommended. Generally, inter-cell handovers are

Adjustment Suggestion

not controlled.
6-9

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.10 SDCCH handover enable (ShoEnable)


Full Name

SDCCH handover enable

Abbreviation

ShoEnable

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates whether SDCCH handover is enabled.

Managed Object

BSC
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

0: No

Default Value

Disable SDCCH handover when MS does not move at high speed

Configuration Reason

because the duration on SD is very short.

Configuration Rule and

SDCCH handover can be enabled for cells covering motorway to

Adjustment Suggestion

improve the access success rate.

Change Mode

Offline

Related features

ZGO-02-02-004 SDCCH/SDCCH Handover

Related Parameters

[Cell]HoControl_0

6-10
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Relationship

A cell can support SDCCH handover only when both the BSC-level
switch and the cell-level switch are enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.11 TCH/F handover enable (TfHoEnable)


Full Name

TCH/F handover enable

Abbreviation

TfHoEnable

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates whether TCH/F handover is enabled.

Managed Object

BSC
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

1: Yes

Default Value

Handover is a basic function in the network. Generally, it is unnecessary

Configuration Reason

to control the channel types in handover.

Configuration Rule and

Handover is a basic function in the network. Generally, it is unnecessary

Adjustment Suggestion

to control the channel types in handover.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

6-11
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.12 TCH/H handover enable (ThHoEnable)


Full Name

TCH/H handover enable

Abbreviation

ThHoEnable

3GPP Name

None

3GPP Reference

None

Description

This parameter indicates whether TCH/H handover is enabled.

Managed Object

BSC
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

1: Yes

Default Value

Handover is a basic function in the network. Generally, it is unnecessary

Configuration Reason

to control the channel types in handover.

Configuration Rule and

Handover is a basic function in the network. Generally, it is unnecessary

Adjustment Suggestion

to control the channel types in handover.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
6-12

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.13 Handover queue enable (HoQueEnable)


Full Name

Handover queue enable

Abbreviation

HoQueEnable

3GPP Name

None

3GPP Reference

None

Description

This parameter decides whether to allow queuing during handovers.

Managed Object

BSC
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

1: Yes

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The default value is Yes in system control parameters. Generally, it


is required to modify only the related cell parameters and eMLPP
parameters.
The default value is Yes in system control parameters. Generally, it
is required to modify only the related cell parameters and eMLPP
parameters to control the level of the cell and the BSC.

Change Mode

Offline

Related features

ZGB-03-01-003 Queuing

Related Parameters

[Cell]QueueInd_1
[BSC]QueueIndHo

Relationship

This function cannot be enabled unless the switches in the BSC-level


and cell-level parameters are all set to Yes.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

YES

6-13
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.14 Handover preemption enable (HoPreEmpt)


Full Name

Handover preemption enable

Abbreviation

HoPreEmpt

3GPP Name

None

3GPP Reference

None
This parameter decides whether to allow forced releases during han-

Description

dovers.

Managed Object

BSC
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

1: Yes

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The default value is Yes in system control parameters. Generally, it


is required to modify only the related cell parameters and eMLPP
parameters.
The default value is Yes in system control parameters. Generally, it
is required to modify only the related cell parameters and eMLPP
parameters to control the level of the cell and the BSC.

Change Mode

Offline

Related features

None

Related Parameters

[Cell]PreemptionInd_1
[BSC]PreemptionIndHo

Relationship

This function cannot be enabled unless the switches in the BSC-level


and cell-level parameters are all set to Yes.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
6-14

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.15 Handover check arithmetic choose (HoA)


Full Name

Handover check arithmetic choose

Abbreviation

HoA

3GPP Name

None

3GPP Reference

None
This parameter indicates the handover decision algorithm.
0: DZD handover algorithm 1
1: DZD handover algorithm 2
...
9: DZD handover algorithm 10

Description

10: Reserved

Managed Object

BSC
0..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
6-15

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork->BSC Managed Element->Config


OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.16 Handover request response (HoAck)


Full Name

Handover request response

Abbreviation

HoAck

3GPP Name

None

3GPP Reference

None
This parameter decides whether the MSC needs to give response
messages during outgoing handovers of the current BSC.
For inter-BSC handovers, if this parameter is set to 1, the HANDOVER
REQUIRED message includes the Response Request information
element.
When the MSC fails to carry out a handover, it will feed back the
Response Request Reject message to the BSC. If this parameter is set
to 0, the MSC will not feed back the Response Request Reject message
to the BSC when it fails to carry out a handover.
When the timer T7 expires, the BSC will regard that the handover

Description

attempt fails.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value

The MSC are not required to give responses, but timeout action will

Configuration Reason

be carried out.

Configuration Rule and


Adjustment Suggestion

It is recommended to set this parameter to 1.

Change Mode

Offline

Related features

ZGB-02-02-001 Basic Handover

Related Parameters

None

Relationship

None
6-16

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

YES
OMC->GERAN Subnetwork->BSC Managed Element->Config

OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.17 Force FACCH (FacchOnly)


Full Name

Force FACCH

Abbreviation

FacchOnly

3GPP Name

None

3GPP Reference

None
This parameter decides whether the assignment uses the TCH/F as the
first priority when requesting a channel. If the parameter is set to Yes, the
settings of the cell parameters FacchCallInd_0, FacchCallInd_1, FacchCallInd_2, and FacchCallInd_3 will not be used. Instead, the TCH/F will

Description

be used first.

Managed Object

BSC
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

0: No

Default Value

By default, the cell-level switch is used. In system control parameters,

Configuration Reason

this parameter is not used as the first priority.

Configuration Rule and

The default value is recommended. If you want to control the FACCH,

Adjustment Suggestion

you can use cell parameters.

Change Mode

Offline

Related features

ZGB-03-01-004 Immediate TCH Assignment

Related Parameters

[Cell]FacchCallInd_0/1/2/3

6-17
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If this parameter is set to Yes, the settings of the cell parameters


FacchCallInd_0, FacchCallInd_1, FacchCallInd_2, and FacchCallInd_3
Relationship

will not be used. Instead, the TCH/F will be used first.


If the parameter is set to No, the system will decide whether to
use the TCH/F first according to the settings of the cell parameters
FacchCallInd_0, FacchCallInd_1, FacchCallInd_2, and FacchCallInd_3.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.18 Continuous handover trigger (HoTrigger)


Full Name

Continuous handover trigger

Abbreviation

HoTrigger

3GPP Name

None

3GPP Reference

None
This parameter indicates the number of handover times, which is only for

Description

internal use.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None
6-18

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.19 Handover reason tip (HoCauseInd)


Full Name

Handover reason tip

Abbreviation

HoCauseInd

3GPP Name

None

3GPP Reference

None
This parameter indicates the cause of an initiated handover, which is only

Description

for internal use.

Managed Object

BSC
0..7
0: No handover;
1..2 : Intra-cell handover;

Value Range and Step

3..7 : Inter-cell handover, or external handover

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None
6-19

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork->BSC Managed Element->Config

OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.20 Local cell position number (LAC)


Full Name

Local cell position number

Abbreviation

LAC

3GPP Name

None

3GPP Reference

None
This parameter is used internally to indicate the location area ID of the

Description

local cell in handovers.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

0
6-20

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork->BSC Managed Element->Config

OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.21 Local cell identity (CI)


Full Name

Local cell identity

Abbreviation

CI

3GPP Name

None

3GPP Reference

None
This parameter is used internally to indicate the ID of the local cell in

Description

handovers.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

6-21
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC->GERAN Subnetwork->BSC Managed Element->Config


OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.22 Outer cell target number (OutCellNum)


Full Name

Outer cell target number

Abbreviation

OutCellNum

3GPP Name

None

3GPP Reference

None
This parameter is used internally to indicate the number of the external

Description

target cells in handovers.

Managed Object

BSC
0..3

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork->BSC Managed Element->Config

OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

6-22
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.23 Outer cell position number 1 (OutLAC1)


Full Name

Outer cell position number 1

Abbreviation

OutLAC1

3GPP Name

None

3GPP Reference

None
This parameter is used internally to indicate the location area ID 1 of the

Description

external target cell in handovers.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork->BSC Managed Element->Config

OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

6-23
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

6.1.24 Outer cell position number 2 (OutLAC2)


Full Name

Outer cell position number 2

Abbreviation

OutLAC2

3GPP Name

None

3GPP Reference

None
This parameter is used internally to indicate the location area ID 2 of the

Description

external target cell in handovers.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork->BSC Managed Element->Config

OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-24
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

6.1.25 Outer cell position number 3 (OutLAC3)


Full Name

Outer cell position number 3

Abbreviation

OutLAC3

3GPP Name

None

3GPP Reference

None
This parameter is used internally to indicate the location area ID 3 of the

Description

external target cell in handovers.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork->BSC Managed Element->Config

OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.26 Outer cell number 1 (OutCI1)


Full Name

Outer cell number 1

6-25
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

OutCI1

3GPP Name

None

3GPP Reference

None
This parameter is used internally to indicate the ID 1 of the external target

Description

cell in handovers.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork->BSC Managed Element->Config

OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.27 Outer cell number 2 (OutCI2)


Full Name

Outer cell number 2

Abbreviation

OutCI2

3GPP Name

None

3GPP Reference

None
6-26

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

This parameter is used internally to indicate the ID 2 of the external target


Description

cell in handovers.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork->BSC Managed Element->Config

OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.28 Outer cell number 3 (OutCI3)


Full Name

Outer cell number 3

Abbreviation

OutCI3

3GPP Name

None

3GPP Reference

None
This parameter is used internally to indicate the ID 3 of the external target

Description

cell in handovers.

Managed Object

BSC
6-27

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

0..65535
Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork->BSC Managed Element->Config

OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.29 Outer RNC 1 (OutRNC1)


Full Name

Outer RNC 1

Abbreviation

OutRNC1

3GPP Name

None

3GPP Reference

None
This parameter is used internally to indicate the RNC_ID 1 of the external

Description

target 3G cell in handovers.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None
6-28

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork->BSC Managed Element->Config

OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.30 Outer RNC 2 (OutRNC2)


Full Name

Outer RNC 2

Abbreviation

OutRNC2

3GPP Name

None

3GPP Reference

None
This parameter is used internally to indicate the RNC_ID 2 of the external

Description

target 3G cell in handovers.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None
6-29

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control

OMC->GERAN Subnetwork->BSC Managed Element->Config


Parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.31 Outer RNC 3 (OutRNC3)


Full Name

Outer RNC 3

Abbreviation

OutRNC3

3GPP Name

None

3GPP Reference

None
This parameter is used internally to indicate the RNC_ID 3 of the external

Description

target 3G cell in handovers.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline
6-30

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork->BSC Managed Element->Config

OMC Access Path

Set->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.32 Old BSS to new BSS information (OldToNewctrl)


Full Name

Old BSS to new BSS information

Abbreviation

OldToNewctrl

3GPP Name

None

3GPP Reference

44018 9.1.15 Handover command


This parameter controls the content of the information element "Old
BSS to New BSS information" in the HANDOVER REQUIRED message
in outcoming handovers.
BIT0: decides whether to send Current Channel Type 2. The value "0"
means "no" and "1" means "yes".
BIT1: decides whether to send Target cell radio information. The value
"0" means "no" and "1" means "yes".
BIT2: decides whether to send MultiRate configuration information.
The value "0" means "no" and "1" means "yes".
BIT3: decides whether to send Inter RAT Handover Info. The value "0"
means "no" and "1" means "yes".
BIT4: decides whether to set frequency hopping parameters by using
FreqList. The value "0" means "no" and "1" means "yes".
BIT5: decides whether to optimize AMR multi-rate configuration
parameters. The value "0" means "no" and "1" means "yes".
BIT6: decides whether to optimize cipher mode parameters. The value

Description

"0" means "no" and "1" means "yes".

6-31
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

BIT7: decides whether to optimize synchronization indication


parameters. The value "0" means "no" and "1" means "yes".
Managed Object

BSC

Value Range and Step

0..255; step: 1

Unit

None

Default Value

64

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Generally, the default value is recommended. However, you can enable

Adjustment Suggestion

this function if necessary.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.33 BSC Internal Handover Parameter of IPA (IPAInterHo)


Full Name

BSC Internal Handover Parameter of IPA

Abbreviation

IPAInterHo

3GPP Name

None

3GPP Reference

None

6-32
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Describes the parameters of handover mode selection for intra-BSC CS


service handover in the case of 3GPP IPA. By default, the internal handover uses compatible versions. The procedure is performed in accordance with the protocol. When the parameter is set to 1, the service
handover from AMR-HR to AMR-FR using SET 1 can follow the handover procedure supported by the MSC. When the parameter is set to
2, the intra-BSC handover can be performed to switch to the BSC-preDescription

ferred speech version.

Managed Object

BSS
0Using compatible version after Internal handover
1Using MSC support handover In AHR to AFR using SET1
2Internal handover to the BSC preferred speech version
3Using MSC support handover In AFR to AHR using SET1
4Using MSC support handover In AFR to AHR using SET1 and In

Value Range and Step

AHR to AFR using SET1

Unit

None

Default Value

0Using compatible version after Internal handover

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value is in accordance with the protocol.


The default value is 0. To connect to the ZTE core network, set the
parameter to 4. To ensure the handover to a preferred speech version,
set the parameter to 2.

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.710d

Parameter Modifying
Detail

New

6-33
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.1.34 Send suspend message when GPRS suspension


(ResumeSetOpt)
Full Name

Send suspend message when GPRS suspension

Abbreviation

ResumeSetOpt

3GPP Name

None

3GPP Reference

None
This parameter decides whether to initiate the GB-interface suspend

Description

process in GPRS suspensions. See TS 48.018 for details.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

The default value depends on the processing mode of the CN.

Configuration Rule and


Adjustment Suggestion

The default value depends on the processing mode of the CN.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-34
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

6.1.35 Queuing indicator in handover required message


(HandOutQueInd)
Full Name

Queuing indicator in handover required message

Abbreviation

HandOutQueInd

3GPP Name

None

3GPP Reference

None
This parameter indicates whether queuing is allowed during inter-BSC
outgoing handovers, that is, whether queuing is allowed according to the

Description

Queuing Indicator parameter in the Handover Required message.

Managed Object

BSC

Value Range and Step

Handout queue disable, Handout queue enable

Unit

None

Default Value

Handout queue disable

Default Value
Configuration Reason

The BSC decides whether to carry out a handover whenever it receives


a measurement report. During such decisions, the BSC possibly select
different target cells.
During inter-BSC handovers, if channel congestion occurs in the target
cell, queuing can relieve the congestion. In this case, this parameter

Configuration Rule and


Adjustment Suggestion

of the source BSC must be set to "Handout queue enable", so that


the Queuing Indicator parameter in the Handover Required message
indicates queuing is allowed. In this way, the MSC indicates the target
BSC that queuing is allowed through the HANDOVER REQUEST
message.

Change Mode

Offline

Related features

ZGO-01-03-001 eMLPP

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Set System Control Parameter->Operation


Control Parameters

Parameter Modifying
Version

None

6-35
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Detail

None

6.1.36 Send cell prefer indication (SendCellPreferInd)


Full Name

Send cell prefer indication

Abbreviation

SendCellPreferInd

3GPP Name

None

3GPP Reference

None
This parameter decides whether to include Cell Prefer Ind in the complete
L3 messages. When China Mobile's IPA is applied to the A interface,
setting this parameter to Yes allows including the parameter Cell Prefer
Ind in the complete L3 messages. In this case, the channel type that the
current BSC prefers to allocate will be notified to the MSC according to
the degree of busyness of the current cell (whether the load threshold of
half-rate channel allocation is reached), so that the MSC can decide the

Description

priority of the allocated channel types.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

China Mobile's IPA is not commonly used.

Configuration Rule and

When China Mobile's IPA is applied to the A interface, this parameter

Adjustment Suggestion

should be set to Yes. Otherwise, it should be set to No.

Change Mode

Offline

Related features

ZGO-05-04-003 A over IP

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Set System Control Parameter->Operation


Control Parameters

6-36
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.37 IPA AMR start mode (IpaAMRStartMode)


Full Name

IPA AMR start mode

Abbreviation

IpaAMRStartMode

3GPP Name

None

3GPP Reference

None
This parameter indicates the initial AMR rate when IPA is applied. When
IPA is applied, the ACS of AMR speech coding modes is specified by
the MSC, so the initial rate cannot be exactly decided. For this reason,
the default rate or the maximum rate is used as the initial rate, and this
applies when ACS is a rate set.
When this parameter is set to Default, the initial rate is coded according
to the default value specified in the protocol 45.009.
When one mode is used, the corresponding rate is used as the initial
coding mode.
When two or three modes are used, the lowest rate is used as the
initial coding mode.
When four modes are used, the second lowest rate is used as the initial

Description

coding mode.

Managed Object

BSC

Value Range and Step

imum rate as the initial rate

Unit

None

Default Value

Default Value

When the default initial rate is used, the initial rate is a strong coding

Configuration Reason

mode that applies to the cases in which the radio signal quality is poor.

0: To use the Default initial rate (the protocol 45.009); 1: To use the max-

Configuration Rule and


Adjustment Suggestion

Generally, the default initial rate is recommended. When the radio signal
quality of the cell is good, you can use the maximum rate as the initial
rate.

Change Mode

Offline

Related features

ZGO-05-04-003 A over IP

Related Parameters

None

Relationship

None

6-37
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

UmAbis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Set System Control Parameter->Operation


Control Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.38 TDD cell handover enable (TdHoEnable)


Full Name

TDD cell handover enable

Abbreviation

TdHoEnable

3GPP Name

None

3GPP Reference

None

Description

This parameter decides whether the handovers to TDD cells are allowed.

Managed Object

BSC

Value Range and Step

0: Yes; 1: No

Unit

None

Default Value

Yes

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

The default value is recommended if TDD cells are configured in the

Adjustment Suggestion

network.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO
6-38

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.39 ICM optimize when intra BSC handover (AmrHoOpt_0)


Full Name

ICM optimize when intra BSC handover

Abbreviation

AmrHoOpt_0

3GPP Name

Internal

3GPP Reference

None
This parameter decides whether to carry out intra-BSC ICM optimization.
ICM optimization refers to using the same voice rate before and after
a handover when AMR is used. When this switch is enabled, if the
BSC receives the pre-handover response from the BTS, it will send the
handover command to the MS. In the command, ICMI and startmode in
the parameter MultiRateconfiguration use the values contained in the
pre-handover response. Otherwise, ICMI and startmode use the values

Description

set in the NMS.

Managed Object

BSC
Yes, No

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value

The ICM optimization function has only a little effect on voice quality,

Configuration Reason

so it is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this function is disabled. However, you can enable it when the
voice quality is poor during handovers to check voice quality changes by
collecting users' feedbacks and measuring the MOS value.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)

Related Parameters

None

Relationship

None

Related Interfaces

Um
6-39

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.40 ICM optimize when inter BSC handover (AmrHoOpt_1)


Full Name

ICM optimize when inter BSC handover

Abbreviation

AmrHoOpt_1

3GPP Name

Internal

3GPP Reference

None
This parameter decides whether to carry out inter-BSC ICM optimization.
ICM optimization refers to using the same voice rate before and after
a handover when AMR is used. When this switch is enabled, if the
BSC receives the pre-handover response from the BTS, it will send the
handover command to the MS. In the command, ICMI and startmode in
the parameter MultiRateconfiguration use the values contained in the
pre-handover response. Otherwise, ICMI and startmode use the values
set in the NMS.

Description

This parameter is supported from V6.20.21.

Managed Object

BSC
Yes, No

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value

The ICM optimization function has only a little effect on voice quality,

Configuration Reason

so it is disabled by default.

Configuration Rule and


Adjustment Suggestion

Generally, this function is disabled. However, you can enable it when the
voice quality is poor during handovers to check voice quality changes by
collecting users' feedbacks and measuring the MOS value.

Change Mode

Offline

Related features

ZGO-01-01-003 Adaptive Multi-rate Codec (AMR)


6-40

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.41 The switch of connection and radio channel activating


synchronization (CallDelayCtrl)
Full Name

The switch of connection and radio channel activating synchronization

Abbreviation

CallDelayCtrl

3GPP Name

None

3GPP Reference

None
This parameter is the switch of connection and radio channel activating
synchronization.
When Abis interface adopts E1 transmission, the longer the delay of
LAPD packets, the longer the delay for message interaction becomes.
Meanwhile, BSC sends a command of connection and channel activating
to BTS, so as to reduce the message interaction delay. If Abis interface

Description

adopts transmission in IP mode, the delay is not reduced obviously.

Managed Object

BSC

Value Range and Step

Yes/No

Unit

None

Default Value

No

Default Value

Newly added switch. The default configuration keeps the same with

Configuration Reason

that of no switch.

6-41
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

If Abis interface adopts E1 transmission, it is recommended to enable


Configuration Rule and

this switch, so as to reduce the delay of message interaction , and the

Adjustment Suggestion

delay of radio access (about 100ms). If the Abis interface adopts IP


transmission, the delay is not reduced obviously.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.42 Include trace ID in handover required (HoRqdCtrl_0)


Full Name

Include trace ID in handover required

Abbreviation

HoRqdCtrl_0

3GPP Name

None

3GPP Reference

None
This parameter indicates whether the HANDOVER REQUIRED
message contains TRACEID.
It is mainly used to CDT trace call. When the call handover is performed
at the external cell, the TRACEID message is added to and transmitted

Description

in the field OldBssToNewBssInformation.

Managed Object

BSC

Value Range and Step

Yes/No

Unit

None

Default Value

No

6-42
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Default Value

This switch, a new switch, exists or not, setting of the default value is

Configuration Reason

the same.

Configuration Rule and


Adjustment Suggestion

The switch can be enabled after CDT is enabled on site.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.43 Inter BSC handover out on SDCCH permitted


(InterBSCSDHOout)
Full Name

Inter BSC handover out on SDCCH permitted

Abbreviation

InterBSCSDHOout

3GPP Name

Internal

3GPP Reference

None
This parameter indicates whether inter-BSC handover on SDCCH is
allowed. When the parameter value is 1, the target cell of a handover
on SDCCH can be an external cell. When the parameter value is 0, an

Description

external cell cannot be the target cell of a handover on SDCCH.

Managed Object

BSC
Yes, No

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No
6-43

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

The default value of this parameter is set to 0 due to the possibility that
Default Value

the MSC fails to appropriately process handover on SDCCH because

Configuration Reason

an inter-BSC handover needs a long time to be completed and the BSC


has a large coverage in many cases.
Generally, it is recommended to set the parameter value to 0. The

Configuration Rule and

parameter value can be set to 1 when inter-cell handover on SDCCH is

Adjustment Suggestion

necessary in some scenarios (for example, a scenario of motorway) and


the MSC has a good capability for processing handover on SDCCH.

Change Mode

Offline

Related features

ZGO-02-02-004 SDCCH/SDCCH Handover

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

Yes
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.44 Use BER to average quality (RQAvgUseBER)


Full Name

Use BER to average quality

Abbreviation

RQAvgUseBER

3GPP Name

None

3GPP Reference

None
This parameter indicates whether BER is used for quality averaging.
When this switch is enabled, the RQ level is converted into BER and
then used for the averaging of measurement report. When this switch is
disabled, the RQ level is directly used for the averaging of measurement

Description

report.

Managed Object

BSC

6-44
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

1: Yes
Value Range and Step

0: No

Unit

None

Default Value

No

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


The calculation result when BER is used is slightly different from that
when the RQ level is directly used. It is recommended to disable this
switch if the handover success ratio is normal.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->System Control Parameter->Operation Control

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


Parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.45 Check IMSI when access (CheckIMSIWhenAccess)


Full Name

Check IMSI when access

Abbreviation

CheckIMSIWhenAccess

3GPP Name

None

3GPP Reference

None

6-45
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter decides whether to check IMSI during access.


When some mobile phones re-access the network after call drop, IMSI is
carried in the initial access information, BSC will detect the IMSI conflict
and send CLEAR REQ to MSC, which is taken as call drop both at A
interface and in BSC. If BSC does not check the IMSI conflict, BSC
will not forward CLEAR REQ to the MSC, which is not calculated as a
call drop in BSC. Nevertheless, MSC will detect the conflict and initiate
Description

release so as to reduce the call drop rate.

Managed Object

BSC

Value Range and Step

Yes/No

Unit

None

Default Value

Yes

Default Value

The parameter is a newly added switch, of which the default value is

Configuration Reason

consistent with that of no switch.

Configuration Rule and


Adjustment Suggestion

This function is in conflict with IMSI signalling tracing. If the signalling


tracing is enabled, you can take the default value and do not enable this
function. Otherwise, in other cases, you can enable this function.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.1.46 Allow assign according first measurement report when use


cobcch (CoBcchAssByOneMr)
Full Name

Allow assign according first measurement report when use cobcch


6-46

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Abbreviation

CoBcchAssByOneMr

3GPP Name

Internal Defination

3GPP Reference

None
This parameter determines whether to implement direct assignment to the

Description

second subcell according to the first measurement report.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No
If it is not required to require direct assignment to the second subcell,

Default Value

assignment to the second subcell can be implemented through

Configuration Reason

subsequent inter-subcell handovers. In this case, this function need


not be enabled.

Configuration Rule and


Adjustment Suggestion

When using the Co-BCCH and require direct assignment to the second
subcell, it is required to configure this parameter to "Yes" and meanwhile
observe the assignment success rate.

Change Mode

Offline

Related features

ZGO-04-02-005 Co-BCCH

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6-47
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.1.47 Use N/P when select neighbour cell for Pbgt handover in
Sdcch (NcellSelCtrlPbgt1)
Full Name

Use N/P when select neighbour cell for Pbgt handover in Sdcch

Abbreviation

NcellSelCtrlPbgt1

3GPP Name

Internal Defination

3GPP Reference

None
This parameter is used to control whether the N value, P value, or average
PBGT value is applied for neighbor cell selection in the case of PBGT

Description

handover on the SDCCH channel.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value
Configuration Reason

The original network KPIs remain unchanged.

Configuration Rule and

It is recommended that this switch be enabled. After that, the neighbor

Adjustment Suggestion

cell selection during PBGT handover judgment is more reasonable.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6-48
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

6.1.48 Use N/P when select neighbour cell for Pbgt handover in
Tch (NcellSelCtrlPbgt2)
Full Name

Use N/P when select neighbour cell for Pbgt handover in Tch

Abbreviation

NcellSelCtrlPbgt2

3GPP Name

Internal Defination

3GPP Reference

None
This parameter is used to control whether the N value, P value, or average
PBGT value is applied for neighbor cell selection in the case of PBGT

Description

handover on the TCH channel.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value
Configuration Reason

The original network KPIs remain unchanged.

Configuration Rule and

It is recommended that this switch be enabled. After that, the neighbor

Adjustment Suggestion

cell selection during PBGT handover judgment is more reasonable.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6-49
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.1.49 Use N/P when select neighbour cell for uplink quality
handover in Sdcch (NcellSelCtrlUlQ1)
Full Name

Use N/P when select neighbour cell for uplink quality handover in Sdcch

Abbreviation

NcellSelCtrlUlQ1

3GPP Name

Internal Defination

3GPP Reference

None
This parameter is used to control whether the N value, P value, or average
level value is applied for neighbor cell selection in the case of uplink quality

Description

handover on the SDCCH channel.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value
Configuration Reason

The original network KPIs remain unchanged.

Configuration Rule and

Usually, this switch is disabled. During neighbor cell selection, using the

Adjustment Suggestion

N or P value is more reliable but may cause handover delay.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6-50
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

6.1.50 Use N/P when select neighbour cell for uplink quality
handover in Tch (NcellSelCtrlUlQ2)
Full Name

Use N/P when select neighbour cell for uplink quality handover in Tch

Abbreviation

NcellSelCtrlUlQ2

3GPP Name

Internal Defination

3GPP Reference

None
This parameter is used to control whether the N value, P value, or average
level value is applied for neighbor cell selection in the case of uplink quality

Description

handover on the TCH channel.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value
Configuration Reason

The original network KPIs remain unchanged.

Configuration Rule and

Usually, this switch is disabled. During neighbor cell selection, using the

Adjustment Suggestion

N or P value is more reliable but may cause handover delay.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6-51
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.1.51 Use N/P when select neighbour cell for downlink quality
handover in Sdcch (NcellSelCtrlDlQ1)
Use N/P when select neighbour cell for downlink quality handover in SdFull Name

cch

Abbreviation

NcellSelCtrlDlQ1

3GPP Name

Internal Defination

3GPP Reference

None
This parameter is used to control whether the N value, P value, or average
level value is applied for neighbor cell selection in the case of downlink

Description

quality handover on the SDCCH channel.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value
Configuration Reason

The original network KPIs remain unchanged.

Configuration Rule and

Usually, this switch is disabled. During neighbor cell selection, using the

Adjustment Suggestion

N or P value is more reliable but may cause handover delay.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6-52
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

6.1.52 Use N/P when select neighbour cell for downlink quality
handover in Tch (NcellSelCtrlDlQ2)
Full Name

Use N/P when select neighbour cell for downlink quality handover in Tch

Abbreviation

NcellSelCtrlDlQ2

3GPP Name

Internal Defination

3GPP Reference

None
This parameter is used to control whether the N value, P value, or average
level value is applied for neighbor cell selection in the case of downlink

Description

quality handover on the TCH channel.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value
Configuration Reason

The original network KPIs remain unchanged.

Configuration Rule and

Usually, this switch is disabled. During neighbor cell selection, using the

Adjustment Suggestion

N or P value is more reliable but may cause handover delay.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6-53
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.1.53 Use N/P when select neighbour cell for uplink level handover
in Sdcch (NcellSelCtrlUlLev1)
Full Name

Use N/P when select neighbour cell for uplink level handover in Sdcch

Abbreviation

NcellSelCtrlUlLev1

3GPP Name

Internal Defination

3GPP Reference

None
This parameter is used to control whether the N value, P value, or average
level value is applied for neighbor cell selection in the case of uplink level

Description

handover on the SDCCH channel.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value
Configuration Reason

The original network KPIs remain unchanged.

Configuration Rule and

Usually, this switch is disabled. During neighbor cell selection, using the

Adjustment Suggestion

N or P value is more reliable but may cause handover delay.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6-54
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

6.1.54 Use N/P when select neighbour cell for uplink level handover
in Tch (NcellSelCtrlUlLev2)
Full Name

Use N/P when select neighbour cell for uplink level handover in Tch

Abbreviation

NcellSelCtrlUlLev2

3GPP Name

Internal Defination

3GPP Reference

None
This parameter is used to control whether the N value, P value, or average
level value is applied for neighbor cell selection in the case of uplink level

Description

handover on the TCH channel.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value
Configuration Reason

The original network KPIs remain unchanged.

Configuration Rule and

Usually, this switch is disabled. During neighbor cell selection, using the

Adjustment Suggestion

N or P value is more reliable but may cause handover delay.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6-55
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.1.55 Use N/P when select neighbour cell for downlink level
handover in Sdcch (NcellSelCtrlDlLev1)
Full Name

Use N/P when select neighbour cell for downlink level handover in Sdcch

Abbreviation

NcellSelCtrlDlLev1

3GPP Name

Internal Defination

3GPP Reference

None
This parameter is used to control whether the N value, P value, or average
level value is applied for neighbor cell selection in the case of downlink

Description

level handover on the SDCCH channel.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value
Configuration Reason

The original network KPIs remain unchanged.

Configuration Rule and

Usually, this switch is disabled. During neighbor cell selection, using the

Adjustment Suggestion

N or P value is more reliable but may cause handover delay.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6-56
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

6.1.56 Use N/P when select neighbour cell for downlink level
handover in Tch (NcellSelCtrlDlLev2)
Full Name

Use N/P when select neighbour cell for downlink level handover in Tch

Abbreviation

NcellSelCtrlDlLev2

3GPP Name

Internal Defination

3GPP Reference

None
This parameter is used to control whether the N value, P value, or average
level value is applied for neighbor cell selection in the case of downlink

Description

level handover on the TCH channel.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value
Configuration Reason

The original network KPIs remain unchanged.

Configuration Rule and

Usually, this switch is disabled. During neighbor cell selection, using the

Adjustment Suggestion

N or P value is more reliable but may cause handover delay.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6-57
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.1.57 Use Subcell 1 as Cell Load (UseSC1Load)


Full Name

Use Subcell 1 as Cell Load

Abbreviation

UseSC1Load

3GPP Name

Null

3GPP Reference

Null

Description

Use the load of the first subcell as the cell load.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

6.1.58 MS Report Count for Rlt (MrCountForRlt)


Full Name

MS Report Count for Rlt

Abbreviation

MrCountForRlt
6-58

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

3GPP Name

Null

3GPP Reference

Null
The parameter indicates the enough number of MS measurement reports

Description

after handover and before the connection fails.

Managed Object

BSC
[0..10]

Value Range and Step

step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Null

Configuration Rule and


Adjustment Suggestion

Null

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Set System Control Parameter->Operation


Control Parameters

Parameter Modifying
Version

iBSCV6.20.711b

Parameter Modifying
Detail

New

6.1.59 BSC intracell handover enable for circuit switch data


(CSDHoIntraEnable)
Full Name

BSC intracell handover enable for circuit switch data

Abbreviation

CSDHoIntraEnable

3GPP Name

None

3GPP Reference

None
6-59

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Description

BSC intracell handover enable for circuit switch data

Managed Object

BSC

Value Range and Step

1: YES, 0: NO

Unit

None

Default Value

1: YES

Default Value
Configuration Reason

Functional switch. Common handover type. Enabled by default.

Configuration Rule and

Enable the handover function normally. If the handover reduces the data

Adjustment Suggestion

transmission success rate, disable the handover.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

6.1.60 BSC cell handover enable for circuit switch data


(CSDHoInterEnable)
Full Name

BSC cell handover enable for circuit switch data

Abbreviation

CSDHoInterEnable

3GPP Name

None

3GPP Reference

None

Description

BSC cell handover enable for circuit switch data

Managed Object

BSC

Value Range and Step

1: YES, 0: NO
6-60

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Unit

None

Default Value

1: YES

Default Value
Configuration Reason

Functional switch. Common handover type. Enabled by default.

Configuration Rule and

Enable the handover function normally. If the handover reduces the data

Adjustment Suggestion

transmission success rate, disable the handover.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function->System Control Parameter->Operation Control

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Parameters
Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

6.1.61 BSC outer handover enable for circuit switch data


(CSDHoOutEnable)
Full Name

BSC outer handover enable for circuit switch data

Abbreviation

CSDHoOutEnable

3GPP Name

None

3GPP Reference

None

Description

BSC outer handover enable for circuit switch data

Managed Object

BSC

Value Range and Step

1: YES, 0: NO

Unit

None

Default Value

1: YES

6-61
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

Functional switch. Common handover type. Enabled by default.

Configuration Rule and

Enable the handover function normally. If the handover reduces the data

Adjustment Suggestion

transmission success rate, disable the handover.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function->System Control Parameter->Operation Control


Parameters

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

6.2 FUC Parameters


6.2.1 Use system message method when MSC over loaded or link
blocked (MSCSysInfoFlc)
Full Name

Use system message method when MSC over loaded or link blocked

Abbreviation

MSCSysInfoFlc

3GPP Name

None

3GPP Reference

None
This parameter decides whether to use system messaging to carry out
flow control when all MSCs is overloaded (Flow control must be enabled
by the overload) or signalling points are congested.
Using system messaging refers to rejecting the access of some MSs
according to the parameter ACCN in system messages. Using FUC
refers to rejecting the access of some MSs according to the number of

Description

MSs that are randomly accessed to the RACH.

6-62
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Managed Object

BSC

Value Range and Step

System message, FUC

Unit

None

Default Value

FUC
The FUC can initiate flow control according to the importance of services.

Default Value
Configuration Reason

When the MSCs are not heavily overload or the signalling points are not
heavily congested, the FUC-based flow control has less effect on user
satisfaction than the system messaging-based flow control.
This parameter only affects MSC overloads and signalling point
congestions. As the most effective flow control method, the system

Configuration Rule and


Adjustment Suggestion

messaging-based flow control rejects the access of some MSs or


disables the access to the cell. The FUC-based flow control rejects
the access of MSs by access reason. The FUC-based flow control is
recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control parameters->FUC Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.2.2 Start system message method (CPUSysInfoFlc)


Full Name

Start system message method

Abbreviation

CPUSysInfoFlc

3GPP Name

None

3GPP Reference

None

6-63
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter decides whether to enable system messaging-based flow


control when the CPU usage of the CMP increases to the threshold of the
Description

system messaging-based flow control.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

It is recommended to use the FUC-based flow control as a priority. This

Configuration Reason

switch is disabled by default.

Configuration Rule and


Adjustment Suggestion

The parameters CpuSysInfoFlc and CpuFucFlc only affect the CPU flow
control. The CPU flow control can be achieved by using the system
messaging-based flow control along with the FUC-based flow control.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control parameters->FUC Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.2.3 Start limit of system message method (CPUSysInfoCTLCPU)


Full Name

Start limit of system message method

Abbreviation

CPUSysInfoCTLCPU

3GPP Name

None

3GPP Reference

None

6-64
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

This parameter indicates the CMP's CPU usage threshold that triggers the
system messaging-based flow control when being exceeded. That is to
say, if the CPU usage exceeds the threshold and the parameter CpuSysInfoFlc is set to "Yes", the system messaging-based flow control will be
Description

enabled.

Managed Object

BSC

Value Range and Step

0..100; step: 1

Unit

Default Value

65

Default Value
Configuration Reason

For the CMP, CPU usage of 65% or above is generally considered to


be high. In this case, you can selectively put some services under flow
control to avoid higher CPU usage.
"This parameter is valid when the parameter CpuSysInfoFlc is enabled.
Generally, the default value is recommended. The higher the threshold

Configuration Rule and


Adjustment Suggestion

is, the higher the CPU usage must be before flow control is enabled.
Setting an overhigh threshold is bad for congestion relief in busy hours
while setting a too low threshold will result in early flow control and affect
normal services.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]CPUSysInfoFlc

Relationship

This parameter is valid only when the switch CPUSysInfoFlc is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control parameters->FUC Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.2.4 Start FUC flow control (CPUFucFlc)


Full Name

Start FUC flow control

Abbreviation

CPUFucFlc
6-65

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Name

None

3GPP Reference

None
This parameter decides whether to enable FUC-based flow control when
the CPU usage of the CMP increases to the threshold of the FUC-based

Description

flow control.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value

services. When the CPU is not overloaded, the FUC-based flow control

Configuration Reason

has less effect on user satisfaction than the system messaging-based

The FUC can initiate flow control according to the importance of

flow control. Therefore, this parameter is enabled by default.


Configuration Rule and
Adjustment Suggestion

The parameters CpuSysInfoFlc and CpuFucFlc only affect the CPU flow
control. The CPU flow control can be achieved by using the system
messaging-based flow control along with the FUC-based flow control.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control parameters->FUC Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.2.5 Start limit of FUC flow control (CPUFucCtlCPU)


Full Name

Start limit of FUC flow control

Abbreviation

CPUFucCtlCPU

3GPP Name

None
6-66

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

3GPP Reference

None
This parameter indicates the CMP's CPU usage threshold that triggers
the FUC-based flow control when being exceeded. That is to say, if the
CPU usage exceeds the threshold and the parameter CpuFucFlc is set to

Description

"Yes", the FUC-based flow control will be enabled.

Managed Object

BSC

Value Range and Step

0..100; step: 1

Unit

Default Value

75

Default Value
Configuration Reason

For the CMP, CPU usage of 75% or above is generally considered to be


high. In this case, you should put some services under flow control to
avoid higher CPU usage.
This parameter is valid when the parameter CpuFucFlc is enabled.
Generally, the default value is recommended. The higher the threshold

Configuration Rule and

is, the higher the CPU usage must be before flow control is enabled.

Adjustment Suggestion

Setting an overhigh threshold is bad for congestion relief in busy hours


while setting a too low threshold will result in early flow control and affect
normal services.

Change Mode

Offline

Related features

None

Related Parameters

[BSC]CPUFucFlc

Relationship

This parameter is valid only when the switch CPUFucFlc is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control parameters->FUC Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.2.6 If paging flow control due to high CPU (CpuPagingFlc)


Full Name

If paging flow control due to high CPU

6-67
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

CpuPagingFlc

3GPP Name

None

3GPP Reference

None
This parameter decides whether to enable paging flow control when

Description

CPU usage is high.

Managed Object

BSC
Yes, No

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

Generally, the default value is recommended. You can decide whether

Adjustment Suggestion

to enable this switch according to paging messages and CPU usage.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control parameters->FUC Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.2.7 CPU threshold of paging flow control (CpuPagingCtlCpu)


Full Name

CPU threshold of paging flow control

Abbreviation

CpuPagingCtlCpu

3GPP Name

None

3GPP Reference

None
6-68

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

This parameter indicates the CPU usage threshold that triggers the
Description

paging flow control when being exceeded.

Managed Object

BSC

Value Range and Step

0..100; step: 1

Unit

Default Value

80

Default Value
Configuration Reason

This is a special functional switch, which is enabled by default.

Configuration Rule and

You can decide whether to enable this switch according to paging

Adjustment Suggestion

messages and CPU usage.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control parameters->FUC Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.2.8 The maximum control level for MSC overload or link block
(MSCFlcMaxLevel)
Full Name

The maximum control level for MSC overload or link block

Abbreviation

MSCFlcMaxLevel

3GPP Name

None

3GPP Reference

None
This parameter indicates the highest flow control level when MSCs are

Description

overloaded or signalling points are congested.

Managed Object

BSC
6-69

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Value Range and Step

0..10; step: 1

Unit

None

Default Value

6
According to the default FUC threshold, setting the level to 6 can put

Default Value

about half traffic under flow control. If the system load cannot be

Configuration Reason

reduced, the problem possibly lies in system capacity. In this case,


non-FUC-based flow control is recommended.
You can set this parameter according to the setting of the FUC-based

Configuration Rule and


Adjustment Suggestion

flow control bitmap. The higher the value is, the higher the level will be
allowed for the flow control triggered by MSC overloads or signalling
point congestions. Similarly, lower values correspond lower flow control
levels.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control parameters->FUC Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.2.9 The number of channel requests permitted per second


(ChlReqNum)
Full Name

The number of channel requests permitted per second

Abbreviation

ChlReqNum

3GPP Name

None

3GPP Reference

None

6-70
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

This parameter indicates the number of services that can be accepted


by the system per second. It decides the number of channel requests
Description

supported by each module per second.

Managed Object

BSC

Value Range and Step

200..1000; step: 1

Unit

Time

Default Value

400

Default Value
Configuration Reason

The default value is set according to system performance.


Generally, the default value is recommended. You can modify the value

Configuration Rule and

according to the performance counter C110060001. The higher the

Adjustment Suggestion

value is, the higher the number of channel requests processed by the
system will be. Similarly, lower values correspond to lower numbers.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control parameters->FUC Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.2.10 The number of paging messages permitted per second


(PagingNum)
Full Name

The number of paging messages permitted per second

Abbreviation

PagingNum

3GPP Name

None

3GPP Reference

None

6-71
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the number of paging messages that can


be processed by the system per second. The number is controlled
according to the module level. If the actual number exceeds this
Description

parameter, paging messages will be discarded.

Managed Object

BSC

Value Range and Step

50..500; step: 1

Unit

Time

Default Value

300

Default Value
Configuration Reason

The default value is set according to system performance.


Generally, the default value is recommended. You can modify the value

Configuration Rule and


Adjustment Suggestion

according to the performance counter C110060002. The higher the


value is, the higher the number of paging messages processed by the
system will be. Similarly, lower values correspond to lower numbers.

Change Mode

Offline

Related features

ZGB-02-01-001 Paging_FG

Related Parameters

None

Relationship

None

Related Interfaces

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control parameters->FUC Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.3 Exchange Parameters of BCCH


6.3.1 BCCH switch (CanBCCHEx)
Full Name

BCCH switch

Abbreviation

CanBCCHEx

6-72
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

3GPP Name

None

3GPP Reference

None
This parameter indicates whether dynamic BCCH shift function is enabled
in the BSC. Another prerequisite of successful dynamic BCCH shift in a

Description

cell is that this function is also enabled in the cell.

Managed Object

BSC

Value Range and Step

Yes, No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

Enable this switch when the BCCH shift function is required.

Change Mode

Offline

Related features

ZGO-03-04-001 Automatic BCCH Recovery

Related Parameters

[Cell]CanBcchExch

Relationship

The dynamic BCCH shift function only takes effect when the functional
switch of the BSC and that of the cell are both enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of BCCH

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.3.2 Scan BCCH (ScanBCCH)


Full Name

Scan BCCH

Abbreviation

ScanBCCH

3GPP Name

None

3GPP Reference

None
6-73

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter specifies the period for scanning the availability of BCCH
TRX when the dynamic BCCH shift function is enabled in the cell. When
the dynamic BCCH shift function is enabled, the network will scan the
status of BCCH TRXs at the specified period and check whether the shift
criterion is fulfilled. This parameter can reflect the response time of a
Description

BCCH TRX failure.

Managed Object

BSC
600..9000

Value Range and Step

Step: 1

Unit

100ms

Default Value

3000

Default Value
Configuration Reason

A period of five minutes is appropriate, in which the network can find


the cell that needs a BCCH shift in a short time and the system load
will not be impacted.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

ZGO-03-04-001 Automatic BCCH Recovery

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of BCCH

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.3.3 BCCH starting delay (BCCHDelay)


Full Name

BCCH starting delay

Abbreviation

BCCHDelay

3GPP Name

None
6-74

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

3GPP Reference

None
This parameter indicates the initial delay before a BCCH shift. The network will check the status of BCCH TRX when the timer expires. If a

Description

BCCH shift is needed, the network initiates a shift process.

Managed Object

BSC
20..1800

Value Range and Step

Step: 1

Unit

100ms

Default Value

1200

Default Value

A delay of two minutes can avoid a BCCH shift triggered by a reset of

Configuration Reason

TRU, or temporary block.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

ZGO-03-04-001 Automatic BCCH Recovery

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of BCCH

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.3.4 BCCH finishing delay (ReBcchEx)


Full Name

BCCH finishing delay

Abbreviation

ReBcchEx

3GPP Name

None

3GPP Reference

None

6-75
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter indicates the delay time before the success of a BCCH
shift. If no block acknowledgement or block failure message is received
from the BTS before the timer expires, the network will reselect a TRX
for the BCCH shift.
Start: When a block message is sent after a TRX for shift is selected, or
a TRX unblock message is sent.
Stop: When a TRX unblock acknowledgement message is received.
At expiry: Research for the cell that needs a BCCH shift and initiate
Description

the shift when it is found.

Managed Object

BSC
20..1800

Value Range and Step

Step: 1

Unit

100ms

Default Value

1200

Default Value

Generally, the BSC can receive a success or failure response after it

Configuration Reason

sends a TRX block or unblock message to the BTS.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

ZGO-03-04-001 Automatic BCCH Recovery

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of BCCH

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.3.5 Delay of TRX forcible release (TrxRel)


Full Name

Delay of TRX forcible release

6-76
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Abbreviation

TrxRel

3GPP Name

None

3GPP Reference

None
This parameter indicates the delay time for forced release of TRX. During
a BCCH shift, if a TRX carrying CS services is selected as the target TRX
for BCCH shift, the network notifies the TRX to hand over the CS services
to another cell. Upon the expiry of this timer, all services of the TRX will

Description

be forcibly released.

Managed Object

BSC
20..200

Value Range and Step

Step: 1

Unit

100ms

Default Value

60

Default Value

Generally, one minute is enough for the TRX to hand over its CS

Configuration Reason

services to another cell.


The default value is recommended. If it is found in the performance

Configuration Rule and

statistic that forced handover seldom occurs but forced release caused

Adjustment Suggestion

by BCCH shift frequently occurs, you can prolong the delay time
appropriately.

Change Mode

Offline

Related features

ZGO-03-04-001 Automatic BCCH Recovery

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of BCCH

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-77
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.3.6 The maximum cells' amount of simultaneously handover


(MaxChangeProc)
Full Name

The maximum cells' amount of simultaneously handover

Abbreviation

MaxChangeProc

3GPP Name

None

3GPP Reference

None
This parameter determines the number of cells in a module that simulta-

Description

neous BCCH shifts are allowed in these cells.

Managed Object

BSC
1..8

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default value is 2, that is, simultaneous shifts are allowed in at most
two cells. If a greater value is selected, conflict or delay may occur due
to simultaneous shifts in too many cells.

Configuration Rule and

In special cases, set this parameter depending on the actual

Adjustment Suggestion

configuration of cells.

Change Mode

Offline

Related features

ZGO-03-04-001 Automatic BCCH Recovery

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of BCCH

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-78
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

6.3.7 Cell Break Alarm Delay (CellAlarmDelay)


Full Name

Cell Break Alarm Delay

Abbreviation

CellAlarmDelay

3GPP Name

None

3GPP Reference

None
The parameter indicates the BCCH switchover delay time after the connection to the cell is broken. If the BCCH switchover time is successfully

Description

performed during this period, the cell break alarm will not be reported.

Managed Object

BSC

Value Range and Step

0..600

Unit

Default Value

120

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of BCCH

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-79
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.4 Exchange Parameters of SD


6.4.1 Dynamic configuration SDCCH (CanSDCCHDyn)
Full Name

Dynamic configuration SDCCH

Abbreviation

CanSDCCHDyn

3GPP Name

None

3GPP Reference

None
This parameter indicates whether dynamic SDCCH/TCH conversion is
enabled in the BSC. The network can dynamically perform conversions
between SDCCH and TCH when this function is enabled. Another prerequisite of successful dynamic SDCCH/TCH conversion in a cell is that

Description

this function is also enabled in the cell.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

The dynamic SDCCH/TCH conversion function of the BSC cannot be

Adjustment Suggestion

enabled unless this switch is enabled.

Change Mode

Offline

Related features

ZGB-03-02-003 Dynamic Configuration of SDCCH

Related Parameters

[Cell]CanSdcchDyn

Relationship

The dynamic SDCCH/TCH conversion function only takes effect when


the functional switch of the BSC and that of the cell are both enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of SD

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-80
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

6.4.2 Scan SDCCH (ScanSDCCH)


Full Name

Scan SDCCH

Abbreviation

ScanSDCCH

3GPP Name

None

3GPP Reference

None
This parameter indicates the period of scanning idle SDCCHs when the
dynamic SDCCH/TCH conversion function is enabled in a cell. After the
dynamic SDCCH/TCH conversion function is enabled in a network, the
network scans SDCCHs at the period specified by this parameter to find
the number of idle SDCCHs for determining whether to convert SDCCH

Description

back to TCH.

Managed Object

BSC
10..1000

Value Range and Step

Step: 1

Unit

100ms

Default Value

100

Default Value

Generally, a period of 10 seconds or so is appropriate to scan SDCCHs

Configuration Reason

for determining whether to convert SDCCH back to TCH.

Configuration Rule and


Adjustment Suggestion

The default value is recommended. A larger parameter indicates a longer


scanning period. And correspondingly, the conversion from SDCCH
(which used to be converted from TCH) to TCH needs longer time.

Change Mode

Offline

Related features

ZGB-03-02-003 Dynamic Configuration of SDCCH

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of SD

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-81
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.4.3 Delay of TS forcible release (TsRel)


Full Name

Delay of TS forcible release

Abbreviation

TsRel

3GPP Name

None

3GPP Reference

None
This parameter indicates the waiting time before a TS is forcibly released.
During the dynamic conversion from SDCCH to TCH, the TS tries to
switch its service to another TS first. If the switching fails, the TS will

Description

be forcibly released when the timer expires.

Managed Object

BSC
5..200

Value Range and Step

Step: 1

Unit

100ms

Default Value

10

Default Value
Configuration Reason

Generally, a TS can successfully switch its service to another TS within


10 seconds. The TS will be forcibly released if the switching fails within
10 seconds.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

ZGB-03-02-003 Dynamic Configuration of SDCCH

Related Parameters

[BSC]CanSDCCHDyn

Relationship

This parameter is valid only when the CanSDCCHDyn switch is enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of SD

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-82
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

6.4.4 Delay protection (MaxDelay)


Full Name

Delay protection

Abbreviation

MaxDelay

3GPP Name

None

3GPP Reference

None
This parameter is an expiration timer used for delay protection. It specifies the allowable delay before an acknowledgement indicating the completion of dynamic BCCH shift or SDCCH conversion is received from the
BTS when the shift or conversion conditions are met in a cell with the
dynamic BCCH shift function or dynamic SDCCH conversion function en-

Description

abled. When the timer expires, the procedure is restarted.

Managed Object

BSC
1200..2400

Value Range and Step

Step: 1

Unit

100ms

Default Value

1800

Default Value
Configuration Reason

The BSC deems that a restoration to initial state is needed due to an


exception in channel conversion if no ACK or NACK message of channel
conversion is received from the BTS within 3 minutes.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

Configuration of SDCCH

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

ZGO-03-04-001 Automatic BCCH Recovery, ZGB-03-02-003 Dynamic

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config


OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of SD

Parameter Modifying
Version

None

Parameter Modifying
Detail

None
6-83

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.4.5 TCH->SDCCH limit (MinSDCCH)


Full Name

TCH->SDCCH limit

Abbreviation

MinSDCCH

3GPP Name

None

3GPP Reference

None
This parameter specifies the threshold that triggers a TCH-to-SDCCH
conversion in a cell where SDCCH dynamic configuration is enabled.
When the number of idle SDCCHs is lower than this threshold, a TCH-

Description

to-SDCCH conversion is performed.

Managed Object

BSC
2..64

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default threshold is 4, that is, a dynamic SDCCH conversion is

Configuration Reason

generally required when the number of idle SDCCHs is less than 4.

Configuration Rule and


Adjustment Suggestion

The default value is recommended.

Change Mode

Offline

Related features

ZGB-03-02-003 Dynamic Configuration of SDCCH

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of SD

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-84
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

6.4.6 SDCCH->TCH delay (TimeToTch)


Full Name

SDCCH->TCH delay

Abbreviation

TimeToTch

3GPP Name

None

3GPP Reference

None
This parameter is used to specify a time limit to prevent frequent SDCCH/TCH conversions when dynamic SDCCH/TCH conversion is enabled in a cell. That means, an SDCCH that used to be converted from
a TCH can only be converted back to TCH when the time limit is up after
the SDCCH becomes idle. In other words, the conversion from SDCCH
to TCH is not allowed within this time limit. The value of this parameter is
actually a step. The time limit is determined by this step and the SDCCH

Description

scanning period: (Step/3+1)*ScanSDCCH.

Managed Object

BSC
2..64

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

The default value is 4. That is, SDCCH-to-TCH conversion is performed


after two SDCCH scanning periods when enough idle SDCCHs are
available, preventing frequent conversions between SDCCH and TCH.
Set a larger value for this parameter if a longer delay is wanted before
SDCCH-to-TCH conversion. An appropriate parameter value is the sum
of a multiple of 3 and the number 1.

Change Mode

Offline

Related features

ZGB-03-02-003 Dynamic Configuration of SDCCH

Related Parameters

[BSC]ScanSDCCH
TimeToTch is a step determining the delay before a SDCCH-

Relationship

to-TCH conversion. The actual delay time equals to


(TimeToTch/3+1)*ScanSDCCH.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of SD

6-85
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.4.7 Dynamic SDCCH Channel Check Delay (DynSdCheckDelay)


Full Name

Dynamic SDCCH Channel Check Delay

Abbreviation

DynSdCheckDelay

3GPP Name

None

3GPP Reference

None

Description

Dynamic SDCCH Channel Check Delay

Managed Object

BSC
[20..50]

Value Range and Step

Step: 1

Unit

100ms

Default Value

25
The originated call occupies the SDCCH for about 4 seconds, while the

Default Value
Configuration Reason

terminated call 2 seconds. This parameter is used to detect whether


services exist on the SDCCH, and three times of timeout checks are
set. Twice for the originated call, and once for the terminated call. After
that, the channel can be released.

Configuration Rule and


Adjustment Suggestion

Emprical value

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function->Set Systerm Control Parameter->Handover


Parameters of SD

6-86
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Parameter Modifying
Version

iBSCV6.20.712a

Parameter Modifying
Detail

New

6.5 Other Parameters


6.5.1 B2 support AMR (V2TruSupportAMR)
Full Name

B2 support AMR

Abbreviation

V2TruSupportAMR

3GPP Name

None

3GPP Reference

None
Whether the BTS 2.0 carrier on the BTSV2 site supports the AMR voice
algorithm decides whether the services on the carrier can use AMR voice

Description

coding.

Managed Object

BSC

Value Range and Step

0: No 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and


Adjustment Suggestion

This parameter should be set according to the actual carrier.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

6-87
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.2 NC2 support (NC2support)


Full Name

NC2 support

Abbreviation

NC2support

3GPP Name

None

3GPP Reference

None
This parameter is the system control parameter, indicating whether NC2
in the idle status is supported and whether MS reports the packet mea-

Description

surement report in the idle status.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

No

Default Value

The reselection method in idle mode is consistent with that of GSM,

Configuration Reason

that is, NCO.

Configuration Rule and

This parameter is the system control parameter and is not allowed to

Adjustment Suggestion

modify.

Change Mode

Offline

Related features

ZGO-02-02-012 Network Controlled Cell Reselection

Related Parameters

[BSC]CtrlOrder

Relationship

When NC2 is enabled, this parameter is valid.

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control Parameters->Other Parameters

Parameter Modifying
Version

None

6-88
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Parameter Modifying
Detail

None

6.5.3 MR server IP (MRSvrIP)


Full Name

MR server IP

Abbreviation

MRSvrIP

3GPP Name

None

3GPP Reference

None

Description

This parameter specifies the IP address of the MR server.

Managed Object

BSC

Value Range and Step

Four-byte IP address: xxx.xxx.xxx.xxx (the value range of xxx: 0-255)

Unit

None

Default Value

0.0.0.0

Default Value
Configuration Reason

Set this parameter according to the actual configuration of the MR server.

Configuration Rule and


Adjustment Suggestion

Set this parameter according to the actual configuration of the MR server.

Change Mode

Offline

Related features

ZGO-06-01-005 Massive Measurement Report

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-89
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.5.4 MR server port (MRSvrPort)


Full Name

MR server port

Abbreviation

MRSvrPort

3GPP Name

None

3GPP Reference

None

Description

This parameter specifies the port No. of TCP listener on the MR server.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

Set this parameter according to the actual configuration of the MR server.

Configuration Rule and


Adjustment Suggestion

Set this parameter according to the actual configuration of the MR server.

Change Mode

Offline

Related features

ZGO-06-01-005 Massive Measurement Report

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.5 Include BTS power in MR (MrIncludeBtsPwr)


Full Name

Include BTS power in MR

Abbreviation

MrIncludeBtsPwr

3GPP Name

None
6-90

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

3GPP Reference

None
This parameter determines whether the MR contains the field of BTS

Description

power.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value
Configuration Reason

Configuration Rule and


Adjustment Suggestion

When the operator requires that the MR must provide the BTS power
or downlink path loss, and the MR analyzer supports this function,
configure this parameter to "Yes".
When the operator requires that the MR must provide the BTS power
or downlink path loss, and the MR analyzer supports this function,
configure this parameter to "Yes".

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control Parameters->Other Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6.5.6 Enhanced and Preprocessde MR report (EnhanAndPrepMrRpt)


Full Name

Enhanced and Preprocessde MR report

Abbreviation

EnhanAndPrepMrRpt

3GPP Name

Internal Defination

3GPP Reference

None

6-91
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter determines whether the enhanced and the pre-processed


measurement reports are reported to the MR. If this parameter is configured to "Yes", the TRACEID and a value (unit: ms) are attached to various
Description

measurement reports.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

0: No

Default Value

By default, this function is disabled. It is required to enable this function

Configuration Reason

as required and when the MR analyzer supports this function.

Configuration Rule and


Adjustment Suggestion

When the pre-processed or enhanced measurement reports need to be


reported to the MR and the MR analyzer supports the analysis on these
reports, enable this switch.

Change Mode

Offline

Related features

ZGO-06-01-005 Massive Measurement Report

Related Parameters

[BSC]MrRptEnable

Relationship

This parameter is valid only when "R_BSC.MrRptEnable" is configured


to "Yes".

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control Parameters->Other Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6.5.7 Power congest delay (PwrCongDelay)


Full Name

Power congest delay

Abbreviation

PwrCongDelay

3GPP Name

None

3GPP Reference

None

6-92
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

This parameter determines the delay of power congestion. If the time


since the last congestion exceeds this threshold, the system cancels
Description

power freezing.

Managed Object

BSC

Value Range and Step

0..255

Unit

Default Value

30

Default Value

The value 30s can generally avoid frequent power freezing and

Configuration Reason

unfreezing.
If this parameter is configured to a small value, power freezing and

Configuration Rule and

unfreezing will frequently occur. If this parameter is configured to a large

Adjustment Suggestion

value, the system cannot quit the congestion state in time, which has
certain impact on the service performance.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control Parameters->Other Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6.5.8 Enable power dynamic sharing (PwrDynShareSupport_0)


Full Name

Enable power dynamic sharing

Abbreviation

PwrDynShareSupport_0

3GPP Name

None

3GPP Reference

None
This parameter is a switch that decides whether to support the dynamic

Description

power sharing function.

6-93
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

BSC

Value Range and Step

0: No 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.


Enabling this function can increase the usage of the BTS power

Configuration Rule and

resources by sharing the unused power of the carriers that have small

Adjustment Suggestion

transmit power with the carriers that requires large transmit power. In
this way, the maximum transmit power of each carrier is increased.

Change Mode

Offline

Related features

ZGO-04-01-007--Dynamic Power Sharing

Related Parameters

[Cell]PwrDynShare

Relationship

This switch is valid only when the global power sharing switch and the
cell-level power sharing switch are both enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.9 Reduction of TCH initial downlink power according to SDCCH


enable (PwrDynShareSupport_1)
Full Name

Reduction of TCH initial downlink power according to SDCCH enable

Abbreviation

PwrDynShareSupport_1

3GPP Name

None

3GPP Reference

None
This parameter is a switch that decides whether to reduce the initial
downlink power of the TCH according to the SDCCH measurement

Description

report.

6-94
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Managed Object

BSC

Value Range and Step

0: No 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


When this function is enabled, the initial downlink power of the TCH can
be calculated according to the SDCCH measurement report, making
the downlink power more accurate.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.10 Channel power adjustment based on power dynamic sharing


enable (PwrDynShareSupport_2)
Full Name

Channel power adjustment based on power dynamic sharing enable

Abbreviation

PwrDynShareSupport_2

3GPP Name

None

3GPP Reference

None
This parameter is a switch to support the congestion control based on

Description

dynamic power sharing.

Managed Object

BSC
0: No

Value Range and Step

1: Yes
6-95

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Unit

None

Default Value

No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

Configuration Rule and

It is recommended to enable this switch when the dynamic power

Adjustment Suggestion

sharing switch of the BSC is enabled.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

[BSC]PwrDynShareSupport_0

Relationship

The power and congestion control is valid when both


PwrDynShareSupport_0 and PwrDynShareSupport_2 are enabled.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.11 Time interval of channel power adjustment based on power


dynamic sharing (ChannelPwrAdjItvl)
Time interval of channel power adjustment based on power dynamic sharFull Name

ing

Abbreviation

ChannelPwrAdjItvl

3GPP Name

None

3GPP Reference

None
This parameter specifies an interval between power and congestion control actions to prevent performance degrade due to too frequent power
and congestion control actions (for example, intra-cell handover and in-

Description

ter-cell handover).

Managed Object

BSC

6-96
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

5..255
Value Range and Step

Step: 1

Unit

Default Value

10

Default Value

Generally, an interval of 10s can effectively prevent too frequent

Configuration Reason

congestion control actions.

Configuration Rule and


Adjustment Suggestion

The default value is recommended. Reset this parameter appropriately if


intra-cell or inter-cell handover caused by power and congestion control
occurs frequently.

Change Mode

Offline

Related features

ZGO-04-01-007 Dynamic Power Sharing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.12 Ts Block Alarm Swtich (TsBlockAlarmSwitch)


Full Name

Ts Block Alarm Swtich

Abbreviation

TsBlockAlarmSwitch

3GPP Name

None

3GPP Reference

None

Description

Sets whether to raise the air-interface TS block alarm.

Managed Object

BSC

Value Range and Step

Yes/No

Unit

None

Default Value

No
6-97

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

Enabled as required

Configuration Rule and


Adjustment Suggestion

By default, the alarm is not raised.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function ID->System Control Parameter->Other Parameter

Parameter Modifying
Version

iBSCV6.20.713a

Parameter Modifying
Detail

NEW

6.5.13 BER Weight (VoiceQualWeight_0)


Full Name

BER Weight

Abbreviation

VoiceQualWeight_0

3GPP Name

None

3GPP Reference

None
This parameter indicates the weight of BER, a factor influencing the
speech quality measurement. The system increases or decreases the
weight of this factor according to the actual configuration when calculating

Description

the speech quality level.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is not currently in use.

6-98
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Configuration Rule and


Adjustment Suggestion

This parameter is not currently in use.

Change Mode

Offline

Related features

ZGO-06-01-002 Speech Quality Supervision

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.14 FER Weight (VoiceQualWeight_1)


Full Name

FER Weight

Abbreviation

VoiceQualWeight_1

3GPP Name

None

3GPP Reference

None
This parameter indicates the weight of FER, a factor including the speech
quality measurement. The system increases or decreases the weight
of this factor according to the actual configuration when calculating the

Description

speech quality level.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is not currently in use.

Configuration Rule and


Adjustment Suggestion

This parameter is not currently in use.

6-99
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Change Mode

Offline

Related features

ZGO-06-01-002 Speech Quality Supervision

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.15 Handover frequence weight (VoiceQualWeight_2)


Full Name

Handover frequence weight

Abbreviation

VoiceQualWeight_2

3GPP Name

None

3GPP Reference

None
This parameter indicates the weight of handover frequency, a factor influencing the speech quality measurement. The system increases or decreases the weight of this factor according to the actual configuration

Description

when calculating the speech quality level.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is not currently in use.

Configuration Rule and


Adjustment Suggestion

This parameter is not currently in use.

Change Mode

Offline

Related features

ZGO-06-01-002 Speech Quality Supervision


6-100

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.16 DTX weight (VoiceQualWeight_3)


Full Name

DTX weight

Abbreviation

VoiceQualWeight_3

3GPP Name

None

3GPP Reference

None
This parameter indicates the weight of DTX, a factor influencing the
speech quality measurement. The system increases or decreases the
weight of this factor according to the actual configuration when calculating

Description

the speech quality level.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is not currently in use.

Configuration Rule and


Adjustment Suggestion

This parameter is not currently in use.

Change Mode

Offline

Related features

ZGO-06-01-002 Speech Quality Supervision

Related Parameters

None

Relationship

None
6-101

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.17 Coding decode weight (VoiceQualWeight_4)


Full Name

Coding decode weight

Abbreviation

VoiceQualWeight_4

3GPP Name

None

3GPP Reference

None
This parameter indicates the weight of coding/decoding type, a factor
influencing the speech quality measurement. The system increases or
decreases the weight of this factor according to the actual configuration

Description

when calculating the speech quality level.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is not currently in use.

Configuration Rule and


Adjustment Suggestion

This parameter is not currently in use.

Change Mode

Offline

Related features

ZGO-06-01-002 Speech Quality Supervision

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

0
6-102

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.18 Abis transmission error code weight (VoiceQualWeight_5)


Full Name

Abis transmission error code weight

Abbreviation

VoiceQualWeight_5

3GPP Name

None

3GPP Reference

None
This parameter indicates the weight of error code in Abis transmission, a
factor influencing the speech quality measurement. The system increases
or decreases the weight of this factor according to the actual configuration

Description

when calculating the speech quality level.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is not currently in use.

Configuration Rule and


Adjustment Suggestion

This parameter is not currently in use.

Change Mode

Offline

Related features

ZGO-06-01-002 Speech Quality Supervision

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
6-103

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.19 Delay weight (VoiceQualWeight_6)


Full Name

Delay weight

Abbreviation

VoiceQualWeight_6

3GPP Name

None

3GPP Reference

None
This parameter indicates the weight of delay, a factor influencing the
speech quality measurement. The system increases or decreases the
weight of this factor according to the actual configuration when calculating

Description

the speech quality level.

Managed Object

BSC
0..65535

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is not currently in use.

Configuration Rule and


Adjustment Suggestion

This parameter is not currently in use.

Change Mode

Offline

Related features

ZGO-06-01-002 Speech Quality Supervision

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

6-104
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.20 A port resource block threshold (Reslimit_0)


Full Name

A port resource block threshold

Abbreviation

Reslimit_0

3GPP Name

None

3GPP Reference

None
This parameter indicates the threshold of rate that an alarm is raised in

Description

the case of unavailable PCM in A interface.

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

Default Value

80

Default Value
Configuration Reason

This parameter is not currently in use.

Configuration Rule and


Adjustment Suggestion

This parameter is not currently in use.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None
6-105

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.5.21 NSVC resource block threshold (Reslimit_1)


Full Name

NSVC resource block threshold

Abbreviation

Reslimit_1

3GPP Name

None

3GPP Reference

None
This parameter indicates the threshold of rate that an alarm is raised in

Description

the case of unavailable NSVC in Gb interface.

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

Default Value

80

Default Value
Configuration Reason

This parameter is not currently in use.

Configuration Rule and


Adjustment Suggestion

This parameter is not currently in use.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.22 Channel resource block threshold (Reslimit_2)


Full Name

Channel resource block threshold

Abbreviation

Reslimit_2

6-106
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

3GPP Name

None

3GPP Reference

None
This parameter indicates the threshold of rate that an alarm is raised in

Description

the case of unavailable radio channel.

Managed Object

BSC
0..100

Value Range and Step

Step: 1

Unit

Default Value

80

Default Value
Configuration Reason

This parameter is not currently in use.

Configuration Rule and


Adjustment Suggestion

This parameter is not currently in use.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.23 Subcell busy threshold (Reslimit_3)


Full Name

Subcell busy threshold

Abbreviation

Reslimit_3

3GPP Name

None

3GPP Reference

None

6-107
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

When a service is released, the degree of busyness of the sub-cell where


the carrier belongs will be calculated. If the number of idle TCHF and
TCHH/2 channels is more than the number of available channels (including available TCHFs, TCHH/2s, and PDCCHs) multiplied by 1 minus
the threshold degree of busyness of the sub-cell, the CS services in the
sub-cell will be transferred for a better continuity of PS channels. That
is to say, when the degree of busyness of the sub-cell is less than the
Description

threshold, the CS services will be transferred.

Managed Object

BSC
40..100

Value Range and Step

Step: 1

Unit

Default Value

80

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

None
Among the cells that have the same number of idle channels, the higher
the threshold degree of busyness of the cell is, the more likely the CS
services will be to be transferred.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.24 Abis alarm delay time (AbisAlmDelayTime)


Full Name

Abis alarm delay time

Abbreviation

AbisAlmDelayTime

6-108
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

3GPP Name

None

3GPP Reference

None
When a link at the Abis interface is broken, the link disconnection alarm

Description

will not be sent if the broken link recovers in the set delay time.

Managed Object

BSC
0..60

Value Range and Step

Step: 1

Unit

Default Value

Default Value
Configuration Reason

By default, the link disconnection alarm is sent.

Configuration Rule and

It is recommended to enable this function. When the broken link recovers

Adjustment Suggestion

in a short time, no Abis interface link disconnection alarm will be sent.

Change Mode

Offline

Related features

None

Related Parameters

Nonel

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.25 DTX factor (Info_0_8)


Full Name

DTX factor

Abbreviation

Info_0_8

3GPP Name

None

3GPP Reference

None

6-109
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is a factor used to calculate the actual Abis bandwidth to


be allocated when a cell is accessed by IP, the MS in the cell uses the
DTX mode, and the downlink discontinuous transport function is enabled
(that is, the switch DtxUplinkBcch and DtxDwlink are enabled). The actual
Abis bandwidth is the product of the factor and the bandwidth needed for
Description

services. 614This parameter is invalid in version 614.

Managed Object

Cell
20..100

Value Range and Step

Step: 1

Unit

None

Default Value

50

Default Value
Configuration Reason

This parameter is invalid in version 614 and later versions.

Configuration Rule and


Adjustment Suggestion

This parameter is invalid in version 614 and later versions.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control Parameters->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.26 CS traffic threshold of slave to master (SToMTrafficThrs_0)


Full Name

CS traffic threshold of slave to master

Abbreviation

SToMTrafficThrs_0

3GPP Name

None

3GPP Reference

None
6-110

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

To ensure a backup BIPBDSP can back up other master BIPBDSPs,


when a master BIPBDSP is back to normal, the connections on the
backup BIPBDSP will be rolled back to the master BIPBDSP.
However, if the percentage of CS services exceeds the threshold, no
Description

rollback will be carried out.

Managed Object

BSC
0..60

Value Range and Step

Step: 1

Unit

Default Value

5
If there are less than eight connections on one DSP and these

Default Value
Configuration Reason

connections correspond to eight full-rate CS users (excluding


multiplexing), it is regarded that only a few users are released due to
exceptional reasons. In this case, slave-to-master changeovers have no
significant effect on performance data.
The higher the value is, the more CS service users will be released

Configuration Rule and

forcedly and the more effect it will have on performance data. The lower

Adjustment Suggestion

the value is, the fewer CS service users will be released forcedly and
the less effect it will have on performance data.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.27 PS traffic threshold of slave to master (SToMTrafficThrs_1)


Full Name

PS traffic threshold of slave to master

6-111
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

SToMTrafficThrs_1

3GPP Name

None

3GPP Reference

None
To ensure a backup BIPBDSP can back up other master BIPBDSPs,
when a master BIPBDSP is back to normal, the connections on the
backup BIPBDSP will be rolled back to the master BIPBDSP. However, if
the percentage of PS services exceeds the threshold, no rollback will

Description

be carried out.

Managed Object

BSC
0..60

Value Range and Step

Step: 1

Unit

Default Value

15
If there are less than 24 connections on one DSP and these connections

Default Value
Configuration Reason

correspond to less than two or three PS users (excluding multiplexing),


it is regarded that the number of users is small. In this case,
slave-to-master changeovers have no significant effect on performance
data.
The higher the value is, the more PS service users will be released

Configuration Rule and

forcedly and the more effect it will have on performance data. The lower

Adjustment Suggestion

the value is, the fewer PS service users will be released forcedly and
the less effect it will have on performance data.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-112
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

6.5.28 Baseband resource share support (BaseBandShare)


Full Name

Baseband resource share support

Abbreviation

BaseBandShare

3GPP Name

None

3GPP Reference

None

Description

This parameter is a BSC level switch for sharing of baseband resources.

Managed Object

BSC
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

Default Value
Configuration Reason

This parameter is a functional switch, which is disabled by default.

Configuration Rule and

If the traffic distributes in tide mode, this function can be enabled

Adjustment Suggestion

according to operator requirements.

Change Mode

Offline

Related features

ZGO-03-04-005 Baseband Resource Dynamic Sharing

Related Parameters

[Site]BaseBandShare

Relationship

This parameter is a BSC level and site level switch.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control Parameters->Other Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6.5.29 TRX Selection priority for baseband share (BBSharePri)


Full Name

TRX Selection priority for baseband share

Abbreviation

BBSharePri

3GPP Name

None
6-113

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

3GPP Reference

None
This parameter determines the carrier selection sequence during sharing

Description

of baseband resources.

Managed Object

BSC
1: Carrier priorityInterference band level
2: Interference band levelCarrier priority
3: Interference band level only

Value Range and Step

4: Carrier priority only

Unit

None

Default Value

Default Value

Baseband resources are prior to be allocated for the carriers with high

Configuration Reason

priority and low interference band.

Configuration Rule and

Baseband resources are prior to be allocated for the carriers with high

Adjustment Suggestion

priority and low interference band.

Change Mode

Offline

Related features

ZGO-03-04-005 Baseband Resource Dynamic Sharing

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control Parameters->Other Parameters

Parameter Modifying
Version

iBSCV6.20.710

Parameter Modifying
Detail

New

6.5.30 Close back up (CloseBackUp)


Full Name

Close back up

Abbreviation

CloseBackUp

3GPP Name

None

3GPP Reference

None

6-114
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

This parameter decides whether to disable the backup function of the


BIPB DSP and LAPD CPU. In version upgrades, this parameter is set
to Yes to avoid frequent backup adjustments.
Description

This parameter is supported from V6.20.614b.

Managed Object

BSC

Value Range and Step

0: No 1: Yes

Unit

None

Default Value

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

This is a special functional switch, which is disabled by default.


In version upgrades, this parameter is set to Yes to avoid frequent
backup adjustments. After an upgrade succeeds, this parameter should
be set to No.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.31 Auto slave to master enable (AutoSToMEnable)


Full Name

Auto slave to master enable

Abbreviation

AutoSToMEnable

3GPP Name

None

3GPP Reference

None
This parameter decides whether to support automatic BIPB DSP

Description

changeovers from slave mode to master mode.

6-115
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Managed Object

BSC

Value Range and Step

0: No 1: Yes

Unit

None

Default Value

Default Value

The slave BIPBDSP can be used alternately only when this switch is

Configuration Reason

enabled.

Configuration Rule and


Adjustment Suggestion

It is not recommended to disable this switch unless absolutely necessary.

Change Mode

Offline

Related features

None

Related Parameters

SToMTimeBitMap, SToMTrafficThrs_0, SToMTrafficThrs_1


The standby changeback may cause interruption of CS and PS in a
wide area, and has great impact on performance. Therefore, real-time

Relationship

changeback is not used. Usually the changeback is arranged in the low


traffic period. The timepoint and threshold of changeback are set by
SToMTimeBitMap, SToMTrafficThrs_0, SToMTrafficThrs_1.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.32 CIC Manual Block Alarm (CICAlarmSwitch)


Full Name

CIC Manual Block Alarm

Abbreviation

CICAlarmSwitch

3GPP Name

Null

3GPP Reference

Null

Description

The parameter is switch for raising the CIC manual blocking alarm.

Managed Object

BSC

6-116
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

0: No
Value Range and Step

1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


ID->BSC Function ID->System Control Parameters->Other Parameters

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

6.5.33 BVC Manual Block Alarm (BVCAlarmSwitch)


Full Name

BVC Manual Block Alarm

Abbreviation

BVCAlarmSwitch

3GPP Name

Null

3GPP Reference

Null

Description

The parameter is switch for raising the BVC manual blocking alarm.

Managed Object

BSC
0: No

Value Range and Step

1: Yes

Unit

None

Default Value

No

6-117
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Default Value
Configuration Reason

None

Configuration Rule and


Adjustment Suggestion

None

Change Mode

Offline

Related features

Null

Related Parameters

Null

Relationship

Null

Related Interfaces

Null

Impact on Equipment

Impact on service

Negotiation With CN

No

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

iBSCV6.20.711a

Parameter Modifying
Detail

New

6.5.34 Slave to master time bitmap (SToMTimeBitMap)


Full Name

Slave to master time bitmap

Abbreviation

SToMTimeBitMap

3GPP Name

None

3GPP Reference

None
This parameter indicates the time bitmap for the slave-to-master
changeover of the BIPB DSP. Backup data rollback can cause a wide
range of CS and PS service interruption, which has a big effect on
system performance. Therefore, rollback is carried out not in real time,
but in small-traffic hours.
This parameter provides 24 optional time points (from 0 to 23) for
automatic slave-to-master changeovers. Each time point stands for
an hour, ranging from 0 to 23 o'clock. Automatic slave-to-master
changeovers will be carried out only when you select a time point and

Description

enable the function.

Managed Object

BSC

Value Range and Step

0..16777215
6-118

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Unit

None

Default Value

Default Value
Configuration Reason

Generally, the traffic is small at three o'clock in the morning, when the
slave-to-master changeover of the BIPB DSP will cause the minimum
call drops.

Configuration Rule and

You can set this parameter after you find out the smallest-traffic hour

Adjustment Suggestion

according to performance statistics.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->Other Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.5.35 Measurement Result Recording Interval in MSC Invoke Trace


(MITMRRecInt)
The parameter is not used in this version.

6.5.36 Preprocessed Measurement Result Recording Interval in


MSC Invoke Trace (MITPrepMRRecInt)
The parameter is not used in this version.

6.6 IBS Parameters


6.6.1 The method of intelligent TRX poweroff (Info_0_0)
Full Name

The method of intelligent TRX poweroff

6-119
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Abbreviation

Info_0_0

3GPP Name

None

3GPP Reference

None
When the intelligent poweroff function is enabled, this parameter indicates

Description

the criterion to choose a carrier to power off.

Managed Object

BSC

Value Range and Step

0, 1, 0: Traffic per channel; 1: Peak channel load

Unit

None

Default Value

Default Value

Generally, the traffic per channel is used to decide whether to power

Configuration Reason

off a carrier.
Carrier poweroff affects the channel resources of the cell. However,

Configuration Rule and

the traffic per channel does not reflect the changes of these channel

Adjustment Suggestion

resources. Peak channel load can reflect the occupancy of the channel
resources. However, frequent poweron and poweroff must be avoided.

Change Mode

Offline

Related features

ZGO-04-04-002--Load Dependent Intelligent TRX Shutdown

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

OMC->GERAN Subnetwork ID->BSC Managed element ID->Config set


ID->BSC Function->Set Systerm Control Parameter->IBS Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.7 Performance Management Parameters


6.7.1 Pingpong handover duration (PingPongDura)
Full Name

Pingpong handover duration

6-120
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Abbreviation

PingPongDura

3GPP Name

None

3GPP Reference

None
This parameter is a timer used to determine whether a handover is a pingpong handover. The timer is started when an MS is handed over from a
cell. If the MS is handed over back to the source cell, and the interval
between two handovers is shorter than the value of this parameter, this

Description

handover is counted as a ping-pong handover.

Managed Object

BSC
0..60

Value Range and Step

Step: 1

Unit

Default Value

10

Default Value

Generally, the handover is regarded as a ping-pong handover if an MS is

Configuration Reason

handed over forth and back between two cells within 10 seconds.

Configuration Rule and


Adjustment Suggestion

The default value is recommended. The larger the parameter value is,
the longer the time is in which a handover is deemed as a ping-pong
handover.

Change Mode

Offline

Related features

ZGB-02-02-002 Basic Handover Decision

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

Set ID->BSC Function ID->System Control parameters->Performance

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


Management Parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-121
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.7.2 Number of measurement reports for dropped connections


(LatestMeasureRptNum)
Full Name

Number of measurement reports for dropped connections

Abbreviation

LatestMeasureRptNum

3GPP Name

None

3GPP Reference

None
This parameter indicates the number of measurement reports that are
used for averaging before a call drop. According to the analysis of
average level and quality, the cause of the call drop can be found. The
MS periodically reports measurement reports, which can be used to find
the call drop cause. This parameter (LatestMeasureRptNum) indicates
the number of measurement reports received from the MS.
If the number of measurement reports received from the MS is
smaller than LatestMeasureRptNum, the call drop cause cannot be
found, and the call drop will be counted as "other call drops". If the
number of measurement reports received from the MS is larger than
LatestMeasureRptNum, the measurement reports will be averaged to

Description

find the call drop cause.

Managed Object

BSC
0..10

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value is 1. A larger value, 4, is recommended. Generally,

Configuration Reason

the average of four measurement reports is relatively correct.

Configuration Rule and


Adjustment Suggestion

The parameter value 4 is recommended to ensure enough measurement


reports are involved in the averaging so as to obtain more correct data,
such as average level and average quality.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO

6-122
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config


OMC Access Path

Set ID->BSC Function ID->System Control parameters->Performance


Management Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.7.3 Uplink quality threshold (DropBadQualULThs)


Full Name

Uplink quality threshold

Abbreviation

DropBadQualULThs

3GPP Name

None

3GPP Reference

None
This parameter specifies a threshold for the statistics of call drops. A call
drop will be counted as call drop caused by poor uplink quality when the

Description

uplink quality level is greater than this threshold.

Managed Object

BSC
0..70

Value Range and Step

Step: 1

Unit

None

Default Value

50

Default Value
Configuration Reason

The default value is 50. A larger value, 59, is recommended. Generally,


the uplink quality can be regarded as very poor when the uplink quality
level is larger than 59, which are most likely to result in call drops.
You can set this parameter according to the network quality.
In general cases:

Configuration Rule and


Adjustment Suggestion

For populous urban areas with much interference and poor network
quality, you can set this parameter to a higher value and the value 59 is
recommended.
For rural areas with litter interference and good network quality, you can
set this parameter to a lower value and the value 50 is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Abis
6-123

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->System Control parameters->Performance


Management Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.7.4 Downlink quality threshold (DropBadQualDLThs)


Full Name

Downlink quality threshold

Abbreviation

DropBadQualDLThs

3GPP Name

None

3GPP Reference

None
When a call drop occurs, it will be counted as a call drop caused by poor

Description

downlink quality if the downlink quality value is not less than the threshold.

Managed Object

BSC
0..70

Value Range and Step

Step: 1

Unit

None

Default Value

50

Default Value
Configuration Reason

None
You can set this parameter according to the network quality. For
populous urban areas where interference is high and network quality is

Configuration Rule and

poor, you can set this parameter to a higher value and the value 59 is

Adjustment Suggestion

recommended. For rural areas where interference is low and network


quality is good, you can set this parameter to a lower value and the
value 50 is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

6-124
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->System Control parameters->Performance


Management Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.7.5 Uplink signal strength threshold (DropLowSigStrULThs)


Full Name

Uplink signal strength threshold

Abbreviation

DropLowSigStrULThs

3GPP Name

None

3GPP Reference

None
When a call drop occurs, it will be counted as a call drop caused by low

Description

level if the uplink level value is not more than the threshold.

Managed Object

BSC
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

12

Default Value
Configuration Reason

None
You can set this parameter according to the network coverage.

Configuration Rule and


Adjustment Suggestion

For populous urban areas where the network coverage is large, you can
set this parameter to a higher value and the value 10 is recommended.
For rural areas where the network coverage is small, you can set this
parameter to a lower value and the value 8 or 6 is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None
6-125

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->System Control parameters->Performance


Management Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.7.6 Downlink signal strength threshold (DropLowSigStrDLThs)


Full Name

Downlink signal strength threshold

Abbreviation

DropLowSigStrDLThs

3GPP Name

None

3GPP Reference

None
When a call drop occurs, it will be counted as a call drop caused by low

Description

level if the downlink level value is not more than the threshold.

Managed Object

BSC
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

12

Default Value

Generally, if the downlink level is lower than 12, it is considered to be

Configuration Reason

too low and call drops will occur.


You can set this parameter according to the network coverage.

Configuration Rule and


Adjustment Suggestion

For populous urban areas where the network coverage is large, you can
set this parameter to a higher value and the value 14 is recommended.
For rural areas where the network coverage is small, you can set this
parameter to a lower value and the value 12 is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None
6-126

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->System Control parameters->Performance


Management Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.7.7 Excessive TA threshold (DropExcessiveTAThs)


Full Name

Excessive TA threshold

Abbreviation

DropExcessiveTAThs

3GPP Name

None

3GPP Reference

None
When a call drop occurs, it will be counted as a call drop caused by long
TA if the distance between the MS and the network (reflected by the TA

Description

value) is not less than the threshold.

Managed Object

BSC
0..63

Value Range and Step

Step: 1

Unit

None

Default Value

20

Default Value

Generally, if the TA value is higher than 20, the distance between the

Configuration Reason

MS and the BTS is considered to be too long and call drops can occur.
You can set this parameter according to the network coverage.

Configuration Rule and


Adjustment Suggestion

For populous urban areas where site coverage is small, you can set this
parameter to a lower value and the value 10 is recommended.
For rural areas where site coverage is large, you can set this parameter
to a higher value and the value 20 is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

6-127
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

Abis

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config

OMC Access Path

Set ID->BSC Function ID->System Control parameters->Performance


Management Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.8 Baseband Frequency Hopping TRX Exchange


Parameters
6.8.1 Baseband frequency hopping TRX exchange support
(Info_0_1)
Full Name

Baseband frequency hopping TRX exchange support

Abbreviation

Info_0_1

3GPP Name

None

3GPP Reference

None
This parameter decides whether to support automatic baseband frequency hopping switchovers. This function can be enabled only when
the BSC- and cell-level switches are enabled. When a carrier in the
frequency hopping group fails, the system will automatically remove the
carrier from the frequency hopping group and move it back after the

Description

carrier is back to normal.

Managed Object

BSC
1: Yes

Value Range and Step

0: No

Unit

None

Default Value

0: No

Default Value
Configuration Reason

This is a special functional switch, which is disabled by default.

6-128
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Baseband frequency hopping switchover is an auxiliary O&M function


Configuration Rule and
Adjustment Suggestion

of baseband frequency hopping. In a system that is configured with


baseband frequency hopping, this function can prevent some failed
carriers from affecting all carriers in the frequency hopping group.
If you set this parameter to Yes, the function is enabled.

Change Mode

Offline

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

[Cell]Info_0_3

Relationship

This function cannot be enabled unless the switches in the BSC-level


and cell-level parameters are all set to Yes.

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function->System Control Parameter->Baseband Frequency


Hopping TRX Exchange Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.8.2 Baseband frequency hopping TRX exchange scan timer


(Info_1_0)
Full Name

Baseband frequency hopping TRX exchange scan timer

Abbreviation

Info_1_0

3GPP Name

None

3GPP Reference

None
This parameter indicates the time interval to scan whether the carriers of
the baseband frequency hopping need to be switched over.
Start: This timer starts periodically.
Stop: The timer expires.
At expiry: The BSC will check whether any baseband frequency hopping

Description

carrier failure exists.

Managed Object

BSC

6-129
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

600..9000
Value Range and Step

Step: 1

Unit

100 ms

Default Value

3000

Default Value

The default value should be larger than the carrier reset time and the

Configuration Reason

time for the radio configuration data to be sent to the BTS.


This parameter should be set according to the system load and the
failure processing time. The higher the value is, the longer time it

Configuration Rule and

will take for the baseband frequency hopping to be back to normal.

Adjustment Suggestion

Otherwise, the lower the value is, the shorter time it will take. However,
the time must not be shorter than the total value of the parameters
Info_1_16 and Info_2_0.

Change Mode

Offline

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function->System Control Parameter->Baseband Frequency


Hopping TRX Exchange Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.8.3 Baseband frequency hopping TRX configuration timer


(Info_1_16)
Full Name

Baseband frequency hopping TRX configuration timer

Abbreviation

Info_1_16

3GPP Name

None

3GPP Reference

None

6-130
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

After a baseband frequency hopping carrier is switched over, the BTS


configuration must be updated. This parameter indicates the time
interval before the BTS response timer expires.
Start: The BSC removes failed carriers from the frequency hopping
group and sends new configuration to the BTS.
Stop: Sending configuration to the BTS completes.
At expiry: The carrier switchover of the baseband frequency hopping will
Description

fail and a new switchover will be initiated.

Managed Object

BSC
100..3000

Value Range and Step

Step: 1

Unit

100 ms

Default Value

1800

Default Value

Three minutes are long enough to send radio configuration data to the

Configuration Reason

BTS.

Configuration Rule and

sending radio configuration data to the BTS. The value must not be lower

Adjustment Suggestion

than the time that is needed by the BSC to send radio configuration

This parameter should be set to a value that allows the BSC to finish

data to the BTS.


Change Mode

Offline

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function->System Control Parameter->Baseband Frequency


Hopping TRX Exchange Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-131
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

6.8.4 Baseband frequency hopping TRX exchange check delay


timer (Info_2_0)
Full Name

Baseband frequency hopping TRX exchange check delay timer

Abbreviation

Info_2_0

3GPP Name

None

3GPP Reference

None
When the BSC detects that a baseband frequency hopping carrier needs
to be switched over, it will wait for a period of time before making another
check to decide whether a switchover is still needed. This parameter
indicates the dealy time.
Start: The system detects a baseband frequency hopping carrier failure.
Stop: The timer expires.
At expiry: The BSC will remove failed carriers from the frequency

Description

hopping group.

Managed Object

BSC
100..1800

Value Range and Step

Step: 1

Unit

100 ms

Default Value

600

Default Value

If the failed carrier can be back to normal in one minute, no switchover

Configuration Reason

is required.
Shielding the carrier failures in a certain period of time can avoid

Configuration Rule and


Adjustment Suggestion

frequent baseband frequency hopping switchovers caused by transient


carrier failures or carrier resets. The higher the value is, the longer time
it will take for the baseband frequency hopping to be back to normal.
Otherwise, the lower the value is, the shorter time it will take.

Change Mode

Offline

Related features

ZGO-04-03-004 Baseband Frequency Hopping

Related Parameters

None

Relationship

None

Related Interfaces

None

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function->System Control Parameter->Baseband Frequency


Hopping TRX Exchange Parameters

6-132
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.9 GPRS Operation Control Parameters


6.9.1 Two-phase access (TwoPhaseAccess)
Full Name

Two-phase access

Abbreviation

TwoPhaseAccess

3GPP Name

None

3GPP Reference

None
This parameter decides whether the MS uses two-phase access forcedly

Description

to establish links for uplink TBFs on the CCCH.

Managed Object

BSC

Value Range and Step

1: Yes; 0: No

Unit

None

Default Value

Yes

Default Value

The default value is set to know the radio capabilities of the MS as soon

Configuration Reason

as possible.

Configuration Rule and

One-phase access can increase the success rate of link establishments,

Adjustment Suggestion

but cannot maximize the multi-timeslot capability of the MS in time.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->GPRS Operation


Control Parameters

6-133
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.9.2 Send radio status to SGSN (GBMsgSndInd_0)


Full Name

Send radio status to SGSN

Abbreviation

GBMsgSndInd_0

3GPP Name

None

3GPP Reference

None
This parameter decides whether to send the radio status message to
the SGSN in the following cases:
The MS is out of the coverage and the reason is described as "radio
connection with MS interrupted".
Radio quality is poor and the reason is described as "radio quality is not
good enough".
The MS is required to carry out a cell reselection at the network side and
the reason is described as "cell reselection command".
The MS cannot be required to carry out a cell reselection or internal
rerouting at the network side, and the reason is described as "ready
for cell reselection".
PCCO fails and the reason is described as "cell reselection failure".

Description

This parameter is supported from V6.20.21.

Managed Object

BSC
Yes, No

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

The default value depends on the processing mode of the CN.


This parameter depends on the processing mode of the CN. If the CN

Configuration Rule and

will suspend data sending after receiving the Status message, you

Adjustment Suggestion

can set this switch according to the duration of the suspension. If the
suspension affects the DT test, you can disable the switch.

Change Mode

Offline

Related features

None

Related Parameters

None

6-134
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->GPRS Operation


Control Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.9.3 Send LLC discard to SGSN (GBMsgSndInd_1)


Full Name

Send LLC discard to SGSN

Abbreviation

GBMsgSndInd_1

3GPP Name

None

3GPP Reference

None
This parameter decides whether to send discarded LLC frames to the
SGSN. If it is set to Yes, the LLC frames discarded in the local cell will
be sent to the SGSN.

Description

This parameter is supported from V6.20.21.

Managed Object

BSC
Yes, No

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

Yes

Default Value
Configuration Reason
Configuration Rule and
Adjustment Suggestion

The default value depends on the processing mode of the CN.


This parameter depends on the processing mode of the CN. If sending
the discarded LLC frames affects the downlink data flow control of the
CN, it is recommended to disable the sending.

Change Mode

Offline

Related features

None

Related Parameters

None

6-135
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->GPRS Operation


Control Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.9.4 Threshold of quality in radio status (RadStaQuaThs)


Full Name

Threshold of quality in radio status

Abbreviation

RadStaQuaThs

3GPP Name

None

3GPP Reference

None
Upon the overflow of N3105, a RADIO STATUS message is sent to the
SGSN. The RADIO STATUS message contains a cause value: 0 or 1.
The cause value 0 indicates a broken radio link to the MS. The cause
value 1 indicates a poor radio quality. The BSC can judge whether the
cause value in the radio status message is 0 or 1 by comparing the radio
quality provided by the DOWNLINK ACK message with the threshold

Description

specified by this parameter.

Managed Object

BSC
0..31

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value
Configuration Reason

The default value of this parameter depends on the radio link quality.
Set the threshold for radio status according to the actual radio quality

Configuration Rule and

in the network. If the radio quality is poor in common, the parameter

Adjustment Suggestion

value can be appropriately decreased in consideration of the influence of


a possible DT.

6-136
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Gb

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed element ID->Config

OMC Access Path

set ID->BSC Function ID->Set System Control Parameter->GPRS


Operation Control Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.9.5 Send packet TBF release to MS when BSS abnormal


(PacketTBFRel)
Full Name

Send packet TBF release to MS when BSS abnormal

Abbreviation

PacketTBFRel

3GPP Name

None

3GPP Reference

None
If exceptions, such as channel exceptions or FAI response exceptions,
occur at the network side, this parameter will be used to decide whether

Description

to send the TBF release message to the MS.

Managed Object

BSC
Yes, No

Value Range and Step

0: No; 1: Yes

Unit

None

Default Value

No

Default Value
Configuration Reason

The default value depends on the network conditions.

6-137
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This parameter is set according to whether the TBFs should be released


Configuration Rule and

immediately or after the exception expires. If the TBFs are not released

Adjustment Suggestion

immediately, resource releases at the BSC side will be inconsistent with


those at the MS side.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO

OMC Access Path

ID->BSC Function ID->System Control Parameters->GPRS Operation

OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set


Control Parameters
Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.9.6 Initial retry interval in downlink buffer state


(DwBufRetryInterval)
Full Name

Initial retry interval in downlink buffer state

Abbreviation

DwBufRetryInterval

3GPP Name

None

3GPP Reference

None
When a downlink TBF release occurs due to exceptions, the BSSGP will
turn to Buffer status. This parameter indicates the time interval to initiate

Description

an immediate downlink assignment.

Managed Object

BSC
0..255

Value Range and Step

Step: 1

Unit

10 ms

Default Value

10

6-138
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Chapter 6 System Control Parameters

Default Value

The default value is determined according to cell reselection time and

Configuration Reason

reaccess time.

Configuration Rule and

This parameter is set according to cell reselection time and reaccess

Adjustment Suggestion

time. Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->GPRS Operation


Control Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6.9.7 Retry number in downlink buffer state (DwBufRetryNum)


Full Name

Retry number in downlink buffer state

Abbreviation

DwBufRetryNum

3GPP Name

None

3GPP Reference

None
When a downlink TBF release occurs due to exceptions, the BSSGP will
turn to Buffer status. This parameter indicates the number of immediate

Description

downlink assignments that can be initiated in this status.

Managed Object

BSC
0..5

Value Range and Step

Step: 1

Unit

None

Default Value

Default Value

The default value is determined according to cell reselection time and

Configuration Reason

reaccess time.
6-139

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Configuration Rule and

This parameter is set according to cell reselection time and reaccess

Adjustment Suggestion

time. Generally, the default value is recommended.

Change Mode

Offline

Related features

None

Related Parameters

None

Relationship

None

Related Interfaces

Um

Impact on Equipment

Impact on service

Negotiation With CN

NO
OMC->GERAN Subnetwork ID->BSC Managed Element ID->Config Set

OMC Access Path

ID->BSC Function ID->System Control Parameters->GPRS Operation


Control Parameters

Parameter Modifying
Version

None

Parameter Modifying
Detail

None

6-140
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix A

Flow Control Policy Values


Barred
Overload

Class

Rxlev_Ac-

Penalty

Cell select

Level

Number

cess_Min

Time

Offset

-1(255)

-2(254)

-2(254)

-3(253)

-3(253)

-3(253)

-4(252)

-3(253)

-4(252)

-3(253)

11111

-3(253)

-3(253)

11111

-2(254)

-3(253)

11111

-1(255)

-3(253)

10

11111

-3(253)

11

11111

-3(253)

12

10

11111

-3(253)

MaxTx-integer

Retrans

A-1
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This page intentionally left blank.

A-2
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix B

Power Values
GSM900

GSM1800

MS Output
Value

MS Output

Power (dBm)

Value

Power (dBm)

0~2

39

29

36

37

30

34

35

31

32

33

30

...

...

...

16

11

...

...

17

13

18

14

19~31

15 ~ 28

28

B-1
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This page intentionally left blank.

B-2
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix C

Setting of Cell Layers


Adjacent Cell

Current
Cell

GSM

GSM

Sectoral

GSM 900M

GSM 900M

1800M

1800M

Cell

Macro Cell

Micro Cell

Macro Cell

Micro Cell

Pico Cell

Sectoral
Cell

SAME

LOWER

LOWER

LOWER

UPPER

SAME

UPPER

LOWER

LOWER

SAME

LOWER

LOWER

cro Cell

UPPER

UPPER

SAME

LOWER

Pico Cell

UPPER

UPPER

GSM 900M
Macro Cell
GSM 900M
Micro Cell
GSM
1800M
Macro Cell
GSM
1800M Mi-

C-1
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

This page intentionally left blank.

C-2
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix D

Relationship between
Parameter Interface and
Database Value
This section introduces the relation between parameter interface and database value.

Table of Contents
BSC Function Parameters Interface........................................................................ D-1
GERAN External Cell Parameters .......................................................................... D-8
UTRAN External Cell Parameters ........................................................................... D-9
Cell Parameters...................................................................................................... D-9
Cell Object Parameters Interface .......................................................................... D-19

D.1 BSC Function Parameters Interface


D.1.1 Basic Property Parameters
l

Support the maximum length of MNC (MNC3Digits)


Interface value

Database value

2 digits

3 digits

Net Type (Net)


Interface value

Database value

CTCN

CMCN

China

Unicom

Communication

Network

(CUCN)

Railway Telecom Network (RLTN)

China Netcom (CNC)

National Farm Transition Network (NFTN)

D-1
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Interface value

Database value

Network 7

Network 8

SP Type (SpType)
Interface value

Database value

SEP

Signaling Transfer Point (STP)

Signaling terminal end point (STEP)

TC type support (TCType)


Interface value

Database value

Inner TC

Outer TC

Global time zone (GlobalTimeZone)


Interface value

Database Value

(GMT-12:00) Enewetak, Kwajalein Island

-720

(GMT-11:30) Midway Island, Samoan Islands

-690

(GMT-11:30) Midway Island, Samoan Islands

-660

(GMT-10:30) Hawaii

-630

(GMT-10:00) Hawaii

-600

(GMT-09:30) Alaska

-570

(GMT-09:00) Alaska

-540

(GMT-08:30) Western Standard Time (USA


and Canada)

-510

(GMT-08:00) Western Standard Time (USA


and Canada)

-480

(GMT-07:30) Arizona

-450

(GMT-07:00) Arizona

-420

(GMT-06:30) Mexico

-390

(GMT-06:00) Mexico, Saskatchewan

-360

(GMT-05:30) Bogota, Lima

-330

(GMT-05:00) Bogota, Lima, Eastern Standard


Time (USA and Canada)

-300
D-2

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix D Relationship between Parameter Interface and Database Value

Interface value

Database Value

(GMT-04:30) San Diego

-270

(GMT-04:00) San Diego

-240

(GMT-03:30) Newfoundlander

-210

(GMT-03:00) Brasilia, Buenos Aires

-180

(GMT-02:30) Mid-Atlantic

-150

(GMT-02:00) Mid-Atlantic

-120

(GMT-01:30) Cape Verde Islands, Azores Islands

-90

(GMT-01:00) Cape Verde Islands, Azores Islands

-60

(GMT-0:30) Greenwich Mean Time, London

-30

(GMT) Greenwich Mean Time, London

(GMT-0:30) Greenwich Mean Time, London

30

(GMT+01:00) Berlin, Roman, Paris

60

(GMT+01:30) Berlin, Roman, Paris

90

(GMT+02:00) Helsinki, Cairo, Athens

120

(GMT+02:30) Helsinki, Cairo, Athens

150

(GMT+03:00)

Baghdad,

Kuwait,

Riyadh,

Moscow

180

(GMT+03:30) Teheran

210

(GMT+04:00) Baku, Tbilisi

240

(GMT+04:30) Kabul

270

(GMT+05:00) Islamabad, Karachi

300

(GMT+05:30) Calcutta, Madras, Bombay, New


Delhi

330

(GMT+06:00) Alma-ata, Dacca

360

(GMT+06:30) Rangoon

390

(GMT+07:00) Bangkok, Djakarta

420

(GMT+07:30) Bangkok, Djakarta

450

(GMT+08:00) Beijing

480

(GMT+08:30) Beijing

510

(GMT+09:00) Seoul, Tokyo

540

(GMT+09:30) Adelaide, Darwin

570

D-3
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Interface value

Database Value

(GMT+10:00) Canberra, Melbourne, Sydney,


Guam

600

(GMT+10:30) Canberra, Melbourne, Sydney,


Guam

630

(GMT+11:00) Magadan, The Solomon Islands

660

(GMT+11:30) Magadan, The Solomon Islands

690

(GMT+12:00) Wellington, Marshall Islands

720

(GMT+12:30) Wellington, Marshall Islands

750

(GMT+13:00) Nuku'alofa

780

D.1.2 Radio Basic Property Parameters


l

DCS1800/PCS1900 Supported (FuncExt)


Interface value

Database value

DCS1800

PCS1900

MSC version ID (MSCVer)


Interface value

Database value

Release 98 or older

Release 99 or newer

D.1.3 Other Parameters


l

Preferred speech version (half) (PreferSpeechVer)


PreferSpeechVer is a field jointed by half-rate and full-rate. Jointing mode: addition
by bit after shifting
PreferSpeechVer = (PreferSpeechVer _0<<2)+ PreferSpeechVer _1
PreferSpeechVer _0: half-rate
PreferSpeechVer _1: Full-rate

D-4
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix D Relationship between Parameter Interface and Database Value

Note:
In this manual, the shift jointing mode is expressed by a formula.
For
instance, (PreferSpeechVer_0<<2) + PreferSpeechVer_1, meaning the value
of PreferSpeechVer_0 is shifted two bits to left and jointed with the value of
PreferSpeechVer_1.

Interface value

Database value

Not specify the preferred version

Half-rate version 1

Half-rate version 3

Preferred speech version (full) (PreferSpeechVer)


PreferSpeechVer is a field jointed by half-rate and full-rate. Jointing mode: addition
by bit after shifting
PreferSpeechVer = (PreferSpeechVer _0<<2)+ PreferSpeechVer _1
PreferSpeechVer _0: half-rate
PreferSpeechVer _1: Full-rate
Interface value

Database value

Not specify the preferred version

Full-rate version 1

Full-rate version 2

Full-rate version 3

TFOControl
TFOControl is a jointed field. Jointing mode: addition by bit after shift
TFOControl = (TFOControl _3<<3) + (TFOControl _2<<2) + (TFOControl _1<<1) +
TFOControl _0.
TFOControl_0: TFO Enable
TFOControl_1: coding/decoding type optimization enable
TFOControl_2: coding/decoding type unmatched enable
TFOControl_3: AMR optimization mode

D.1.4 AMR Half Method Parameters


l

Initial codec mode (IsAmrlCM)


D-5

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

IsAmrICM is a jointed field in database. AMR half-rate is jointed with full-rate, jointing
mode: IsAmrICM (full) + IsAmrICM (half), jointed by string.
Interface value

Database value

Initial codec mode

Startmode codec

Start mode (AmrStartMode)


AmrStartMode is a jointed field in database. AMR half-rate is jointed with full-rate,
jointing mode: AmrStartMode (full) + AmrStartMode (half), jointed by string.

Enable noise control (IsAmrNscb)


IsAmrNscb is a jointed field in database. AMR half-rate is jointed with full-rate, jointing
mode: IsAmrNscb (full) + IsAmrNscb (half), jointed by string.

Thresholds of AMR (AmrThresholds)


AmrThresholds is a jointed field in database. AMR half-rate is jointed with full-rate,
jointing mode: AmrThresholds (full) + AmrThresholds (half), jointed by string from top
to bottom.

Hysteresis of AMR (AmrHysteresis)


AmrHysteresis is a jointed field in database. AMR half-rate is jointed with full-rate,
jointing mode: AmrHysteresis (full) + AmrHysteresis (half), jointed by string from top
to bottom.

D.1.5 AMR Full Method Parameters


l

Initial codec mode (IsAmrlCM)


IsAmrICM is a jointed field in database. AMR half-rate is jointed with full-rate, jointing
mode: IsAmrICM (full) + IsAmrICM (half), jointed by string.
Interface value

Database value

Initial codec mode

Startmode codec

Start mode (AmrStartMode)


AmrStartMode is a jointed field in database. AMR half-rate is jointed with full-rate,
jointing mode: AmrStartMode (full) + AmrStartMode (half), jointed by string.

Enable noise control (IsAmrNscb)


IsAmrNscb is a jointed field in database. AMR half-rate is jointed with full-rate, jointing
mode: IsAmrNscb (full) + IsAmrNscb (half), jointed by string.

Threshold of AMR (AmrThresholds)


D-6

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix D Relationship between Parameter Interface and Database Value

AmrThresholds is a jointed field in database. AMR half-rate is jointed with full-rate,


jointing mode: AmrThresholds (full) + AmrThresholds (half), jointed by string from top
to bottom.
l

Hysteresis of AMR (AmrHysteresis)


AmrHysteresis is a jointed field in database. AMR half-rate is jointed with full-rate,
jointing mode: AmrHysteresis (full) + AmrHysteresis (half), jointed by string from top
to bottom.

D.1.6 GPRS Property 1 Parameters


l

Cn
CN is a jointed field in the database. Jointing mode: jointed by string from top to
bottom.

Nn
Nn is a jointed field in the database. Jointing mode: jointed by string from top to
bottom.

Xn
Xn is a jointed field in the database. Jointing mode: jointed by string from top to
bottom.

D.1.7 GPRS Property 2 Parameters


l

NACC supported (NACCSupport)


Interface value

Database value

Not support NACC

Support NACC, not support LLC framework


conversion

Support NACC, also support LLC framework


conversion.

Net operation mode (NMO)


Interface value

Database value

Network Operation Mode 1

Network Operation Mode 2

Network Operation Mode 3

Downlink TBF retry (DITBFRetry)

D-7
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Interface value

Database Value

Not retry

Retry 1 times

Retry 2 times

D.1.8 EDGE Parameters


l

SGSN version ID (SGSNVer)


Interface value

Database value

Release 98 or older

Release 99 or newer

R99 Ind (R99Ind)


Interface value

Database Value

non-R99 version

R99 version

D.2 GERAN External Cell Parameters


l

Cell type (CellType)


Interface value

Database value

Umbrella cell

Macro Cell

Micro cell

Pico Cell

Extended range cell

Frequency band (FreqBand)


Interface value

Database value

GSM900

EXT900

DCS1800

PCS1900

GSM850

7
D-8

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix D Relationship between Parameter Interface and Database Value

D.3 UTRAN External Cell Parameters


l

UTRAN cell type (CellType3G)


Interface value

Database value

FDD

TDD

UTRAN adjacent cell bandwidth (BandWidth3G)


Interface value

Database value

0 (3.84Mcps)

1 (1.28Mcps)

D.4 Cell Parameters


D.4.1 Basic Parameters 1
l

Cell type (CellType)


Interface value

Database value

Umbrella cell

Macro Cell

Micro cell

Pico Cell

Extended range cell

Frequency band (FreqBand)


Interface value

Database value

GSM900

EXT900

DCS1800

PCS1900

GSM850

Frequency band of subCell (SubFreqBand)


Interface value

Database value

GSM900

0
D-9

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Interface value

Database value

EXT900

DCS1800

PCS1900

GSM850

GPRS service supported (PsSupport)


Interface value

Database value

No

GPRS service support

Support EDGE

EGPRS2-A support

Common control channel configuration (CcchConf)


Interface value

Database value

CCCH uses one physical channel, not combined with SDCCH

One basic physical channel used by CCCH, use


with SDCCH

Two basic physical channels used by CCCH, do


not use with SDCCH

Three basic physical channels used by CCCH,


do not use with SDCCH

Four basic physical channels used by CCCH,


do not use with SDCCH

D.4.2 Basic Parameters 2


l

AMR codec adjust mode (AmrAdjMode)


Interface value

Database value

AMR rapid speed mode

Adjustment interval for configuration

D.4.3 Other Parameters


l

CipherMode
D-10

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix D Relationship between Parameter Interface and Database Value

CipherMode is a jointed field in database by CipherMode-0~ CipherMode-7. Jointing


mode: jointed by string from top to bottom.

D.4.4 System Parameters


l

InterfBoundary
InterfBoundary is a jointed field in database by InterfBoundary_0~ InterfBoundary_5.
Jointing mode: jointed by string from top to bottom.

D.4.5 GPRS Other Parameters 1


l

SI13 sending position (Si13Locate)


Interface value

Database value

BCCH Norm

BCCH Ext

Packet access priority threshold (PriAcThr)


Interface value

Database value

Disallow packet access

Allow packet access with the priority level 1

Allow packet access with the priority level 1-2

Allow packet access with the priority level 1-3

Allow packet access with the priority level 1-4

Allow priority

D.4.6 GPRS Cell Options Parameters


l

T3168
Interface value

Database value

0.5

1.5

2.5

3.5

7
D-11

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

T3192
Interface value

Database value

500

1000

1500

80

120

160

200

DRX mode holding time (DrxTimeMax, s)


Interface value

Database value

16

32

64

Packet control acknowledgment type (CtraCKType)


Interface value

Database value

4 access burst

RLC/MAC control block

Access burst type (AccessType)


Interface value

Database value

8 bits

11 bits

N3102 decrease step (PanDec)


Interface value

Database value

0
D-12

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix D Relationship between Parameter Interface and Database Value

Interface value

Database value

12

16

20

24

28

32

N3102 increase step (PanInc)


Interface value

Database value

12

16

20

24

28

32

N3102 MAX (PanMax)


Interface value

Database value

12

16

20

24

28

32

GPRS Phone Init Coding


GPRS phone init coding is a jointed field in the database.
1*16Kbps+2~4*16Kbps jointed by string.

Jointing mode:

GPRS phones init code can be changed (InitAttachExch_0)


D-13

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

InitAttachExch is a jointed field.


Jointing mode:
(INITATTACHEXCH_1<<1)+INITATTACHEXCH_0).

addition by bit after shift

InitAttachExch_0: GPRS phones init code can be changed dynamically.


InitAttachExch_1: EGPRS phones init code can be changed

D.4.7 GPRS NC Survey Parameters


l

Packet Idle mode (NcRepPerI, s)


Interface value

Database value

0.48

0.96

1.92

3.84

7.68

15.36

30.72

61.44

Packet transmission mode (NcRepPerT, s)


Interface value

Database value

0.48

0.96

1.92

3.84

7.68

15.36

30.72

61.44

Network control order (CtrlOrder)


Interface value

Database value

NC0

NC1

NC2

NC hold time in non-drx mode (NcNoDrxPer, s)


D-14

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix D Relationship between Parameter Interface and Database Value

Interface value

Database value

No non-DRX mode

0.24

0.48

0.72

0.96

1.2

1.44

1.92

Extended measurement report order (ExMeaOrder)


Interface value

Database value

EM0

EM1

Type of extended measurement report (ExtRepType)


Interface value

Database value

Type 1

Type 2

Type 3

Report period of extended measurement (ExtRepPer, s)


Interface value

Database value

60

120

240

480

960

1920

3840

7680

D.4.8 GPRS Power Control Parameters


l

Power control measurement channel (PcMeasChan)


D-15

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Interface value

Database value

BCCH

PDCH

D.4.9 GPRS Cell Reselection Parameters


l

Cell reselection offset (ReselOffset, 2db)


ReselOffset is a jointed field in database by ReselOff_0 and ReselOff_0. Jointing
mode: ReselOff_0 + ReselOff_1 jointed by string.

Reselection temporary offset (TempOffset, dB)


TempOffset is a jointed field in database by TempOffset_0 and TempOffset_1. Jointing
mode: TempOffset_0+ TempOffset_1 jointed by string.
Interface value

Database value

10

20

30

40

50

60

Large infinite

Penalty time of cell reselection (PenalTime, 10s)


PenalTime is a jointed field in database by PenalTime_0 and PenalTime_1. Jointing
mode: PenalTime_0 + PenalTime_1 jointed by string.

Interval of reselecting the same cell (T_RESEL, s)


T_RESEL is a jointed field in database by T_RESEL_0 and T_RESEL_1. Jointing
mode: T_RESEL_0 + T_RESEL_1 jointed by string.
Interface value

Database value

10

15

20

30

60

5
D-16

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix D Relationship between Parameter Interface and Database Value

Interface value

Database value

120

300

Threshold of HSC signal level (HCS_THR)


HCS_THR is a jointed field in database by HCS_THR_0 and HCS_THR_1. Jointing
mode: HCS_THR_0+HCS_THR_1 jointed by string.

HCS priority (PrioClass)


PrioClass is a jointed field in database by PrioClass_0 and PrioClass_1. Jointing
mode: PrioClass_0+PrioClass_1 jointed by string.

C31 hysteresis (C31_HYST)


C31_HYST is a jointed field in database by C31_HYST_0 and C31_HYST_1. Jointing
mode: C31_HYST_0+C31_HYST_1 jointed by string.

GPRS cell reselection hysteresis (ReselHys, dB)


ReselHys is a jointed field in database by ReselHys_0 and ReselHys_1. Jointing
mode: ReselHys_0+ReselHys_1 jointed by string.

Routing reselection hysteresis (RaReselHys, dB)


RaReselHys is a jointed field in database by RaReselHys_0 and RaReselHys_1.
Jointing mode: RaReselHys_0+RaReselHys_1 jointed by string.

Random access attempt permitted (RadAcRetry)


RadAcRetry is a jointed field in database by RadAcRetry_0 and RadAcRetry_1.
Jointing mode: RadAcRetry_0+RadAcRetry_1 jointed by string.

Usage of cell reselection offset (C32_QUAL)


C32_QUAL is a jointed field in database by C32_QUAL_0 and C32_QUAL_1. Jointing
mode: C32_QUAL_0+C32_QUAL_1 jointed by string.

GPRS access minimum signal level (RxLevAsMin)


RxLevAsMin is a jointed field in database by RxLevAsMin_0 and RxLevAsMin_1.
Jointing mode: RxLevAsMin_0+RxLevAsMin_1 jointed by string.

HCS exist (HCS_EXIST)


HCS_EXIST is a jointed field in database by HCS_EXIST_0 and HCS_EXIST_1.
Jointing mode: HCS_EXIST_0+HCS_EXIST_1 jointed by string.

GPRS MAX initial access signal level (MsTxMaxCch)


MsTxMaxCch is a jointed field in database by MsTxMaxCch_0 and MsTxMaxCch_1.
Jointing mode: MsTxMaxCch_0+MsTxMaxCch_1 jointed by string.

D.4.10 GPRS Channel Parameters


l

Interval range of packet access attempt (TxInt)


D-17

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Interface value

Database value

10

12

14

10

16

11

20

12

25

13

32

14

50

15

Interval period of packet access attempt (S)


Interface value

Database value

12

15

20

30

41

55

76

109

163

217

MAX Times of Attempt (MaxRetrans)


MaxRetrans is a jointed field in database. Jointing mode: jointed by string from top to
bottom.

D-18
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix D Relationship between Parameter Interface and Database Value

Interface value

Database value

Access Control Level (AccCtrlClass)


AccCtrlClass is a jointed field in database. Jointing mode: jointed by string from top
to bottom.

Access Persist Level (PersistLev)


PersistLev is a jointed field in database. Jointing mode: jointed by string from top to
bottom.

D.4.11 EDGE Parameters


l

EGPRS Phone Init Coding


It is a jointed field in database. Jointing mode: jointed by string from top to bottom.
Interface value

Database value

MCS1

MCS2

MCS3

MCS4

MCS5

MCS6

MCS7

MCS8

MCS9

D.5 Cell Object Parameters Interface


D.5.1 TRX Info Parameters
l

TRX type (TrxType)


Interface value

Database value

Common TRX

0
D-19

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Interface value

Database value

Extended TRX

Static power level (PwRreduction)


Interface value

Database Value

Max output power

Max output power -2dB

Max output power -4dB

Max output power -6dB

Max output power -8dB

Max output power -10dB

Max output power -12dB

Max output power +1.5dB

253

Max output power +1dB

254

Max output power +0.5dB

255

D.5.2 Channel Info Parameters


l

TS Channel Combination
Interface value

Database value

TCH/F

TCH/H(0, 1)+FACCH/H(0, 1)+SACCH/TH(0, 1)

TCH/H(0, 0)+FACCH/H(0, 1)+SACCH/TH(0,

1)+TCH/H(0, 1)

SDCCH/8+SACCH/C8

FCCH+SCH+BCCH+CCCH

BCCH+SDCCH/4

BCCH+CCCH

BCCH+SDCCH/4+CBCH

SDCCH+CBCH

PBCCH+PCCCH+PDTCH+PACCH+PTCCH

12

PCCCH+PDTCH+PACCH+PTCCH

13

PDTCH+PACCH+PTCCH

14

Ps Service Preference Property


D-20

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix D Relationship between Parameter Interface and Database Value

Interface value

Database value

No preference

255

GPRS preference

EDGE preference

EDGE exclusion

EGPRS2-A Preference

EGPRS2-A dedicated

D.5.3 Power Control Parameters


l

Power control PwrDecrLimit


It is a jointed field in database. Jointing mode: jointed by string from top to bottom.

Increase uplink level Threshold, Value P, and Value N


It is a jointed field in database. Jointing mode: jointed by string from top to bottom in
the sequence of FR, HR, AMR FR, AMR HR.

Decrease uplink level Threshold, Value P, and Value N


It is a jointed field in database. Jointing mode: jointed by string from top to bottom in
the sequence of FR, HR, AMR FR, AMR HR.

Increase uplink quality Threshold, Value P, and Value N


It is a jointed field in database. Jointing mode: jointed by string from top to bottom in
the sequence of FR, HR, AMR FR, AMR HR.

Decrease uplink quality Threshold, Value P, and Value N


It is a jointed field in database. Jointing mode: jointed by string from top to bottom in
the sequence of FR, HR, AMR FR, AMR HR.

Increase downlink level Threshold, Value P, and Value N


It is a jointed field in database. Jointing mode: jointed by string from top to bottom in
the sequence of FR, HR, AMR FR, AMR HR.

Decrease downlink level Threshold, Value P, and Value N


It is a jointed field in database. Jointing mode: jointed by string from top to bottom in
the sequence of FR, HR, AMR FR, AMR HR.

Increase downlink quality Threshold, Value P, and Value N


It is a jointed field in database. Jointing mode: jointed by string from top to bottom in
the sequence of FR, HR, AMR FR, AMR HR.

Decrease downlink quality Threshold, Value P, and Value N


It is a jointed field in database. Jointing mode: jointed by string from top to bottom in
the sequence of FR, HR, AMR FR, AMR HR.
D-21

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

FR Power increasing step (db) (PWRINCSTEP_0)


PWRINCSTEP is a jointed field in database. Jointing mode: jointed by string from top
to bottom in the sequence of FR, HR, AMR FR, AMR HR.

FR Power decreasing step (db) (PWRREDSTEP_0)


PWRREDSTEP is a jointed field in database. Jointing mode: jointed by string from
top to bottom in the sequence of FR, HR, AMR FR, AMR HR.

MAX power level of MS (MsTxPwrMax)


MsTxPwrMax is a jointed field in database. Jointing mode: jointed by string from top
to bottom in the sequence of FR, HR, AMR FR, AMR HR.

MIN power level of MS (MsTxPwrMin)


MsTxPwrMin is a jointed field in database. Jointing mode: jointed by string from top
to bottom in the sequence of FR, HR, AMR FR, AMR HR.

MIN power level of BS (BxTxPwrMin)


BsTxPwrMin is a jointed field in database. Jointing mode: jointed by string from top
to bottom in the sequence of FR, HR, AMR FR, AMR HR.

MIN interval of power control (PcMinInterval)


PcMinInterval is a jointed field in database. Jointing mode: jointed by string from top
to bottom in the sequence of FR, HR, AMR FR, AMR HR.

D.5.4 Handover Control Parameters


l

Frequency control value for handover on traffic (TrafficHoFreqrCtl)


Interface value

Database value

GSM900

EXT900

DCS1800

PCS1900

GSM850

HoPatternInd
HoPatternInd is a jointed field. Jointing mode: addition by bit after shift.
HoPatternInd = (HoPatternInd4<<3) + (HoPatternInd3<<2) + (HoPatternInd2<<1) +
HoPatternInd1.
HoPatternInd1: Enable synchronized handover
HoPatternInd2: Enable unsynchronized handover
HoPatternInd3: Enable pseudo-synchronization handover
HoPatternInd4: Enable pre-synchronized handover
D-22

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix D Relationship between Parameter Interface and Database Value

HoControl
HoControl is a jointed field. Jointing mode: addition by bit after shift.
HoControl = (HoControl18<<17) + (HoControl17<<16) + (HoControl16<<15) +
(HoControl15<<14) + (HoControl14<<13) + (HoControl13<<12) + (HoControl12<<11)
+ (HoControl11<<10) + (HoControl10<<9) + (HoControl9<<8) + (HoControl8<<7)
+ (HoControl7<<6) + (HoControl6<<5) + (HoControl5<<4) + (HoControl4<<3) +
(HoControl3<<2) + (HoControl2<<1) + HoControl1
HoControl1: Enable SDCCH handover
HoControl2: Enable inter-cell handover attempt due to uplink interference
HoControl3: Enable inter-cell handover attempt due to downlink interference
HoControl4: Enable handover due to distance
HoControl5: Enable standard PBGT handover
HoControl6: Enable automatic handover based on traffic
HoControl7: Enable handover based on direction
HoControl8: Enable handover based on homocentric circularity
HoControl9: Enable intra-cell handover in super TRX channel due to downlink
interference
HoControl10:
interference

Enable intra-cell handover in super TRX channel due to uplink

HoControl11: Enable adjacent cells handover in super TRX channel due to PBGT
HoControl12: Enable dynamic adjustment of handover priority
HoControl13: Enable rapid handover
HoControl14: Enable Macro-Micro delay handover
HoControl15: Enable Micro-Macro delay handover
HoControl16: Enable internal handover based on TA
HoControl17: Enable force transfer handover
HoControl18: Subcell handover algorithm
l

Subcell handover algorithm (HoControl18)


Interface value

Database value

Concentric handover

Path loss and TA handover

D.5.5 UTRAN Cell Control Parameters


l

Measurement threshold of UE performing GPRS UTRAN cell (Qsearch_P)


D-23

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

Qsearch_P is a jointed field in database. Jointing mode: Qsearch_P_0+Qsearch_P_1


jointed by string.
Qsearch_P_0: idle
Qsearch_P_1: packet transmission
l

FDD GPRS reselection offset (FDD_GPRS_Qoffset)


FDD_GPRS_Qoffset is a jointed field in database.
Jointing
FDD_GPRS_Qoffset_0+ FDD_GPRS_Qoffset_1 jointed by string.

mode:

FDD_GPRS_Qoffset_0: Idle
FDD_GPRS_Qoffset_1: packet transmission
l

TDD GPRS reselection offset (TDD_GPRS_Qoffset)


TDD_GPRS_Qoffset is a jointed field in database.
Jointing
TDD_GPRS_Qoffset_0+ TDD_GPRS_Qoffset_1 jointed by string.

mode:

TDD_GPRS_Qoffset_0: Idle
TDD_GPRS_Qoffset_1: packet transmission
l

PS MIN Ec/No of UTRAN reselecting cell (FDD_QminPS)


FDD_QminPS is a jointed field in database.
FDD_QminPS_1 jointed by string.

Jointing mode: FDD_QminPS_0+

FDD_QminPS_0: Idle
FDD_QminPS_1: packet transmission
l

Offset of FDD_QminPS (FDD_Qmin_OffsetPS)


FDD_Qmin_OffsetPS is a jointed field in database.
Jointing
FDD_Qmin_OffsetPS_0+FDD_Qmin_OffsetPS_1 jointed by string.

mode:

FDD_Qmin_OffsetPS_0: idle
FDD_Qmin_OffsetPS_1: packet transmission
l

PS MIN RSCP of UTRAN reselecting cell (FDD_RSCPminPS)


FDD_RSCPminPS is a jointed field in database.
FDD_RSCPminPS_0+FDD_RSCPminPS_1 jointed by string.

Jointing

mode:

FDD_RSCPminPS_0: Idle
FDD_RSCPminPS_1: Packet transmission
l

Measurement report threshold of Ec/No or RSCP (FDDRprtTho2PS)


FDDRprtTho2PS is a jointed field in database.
FDDRprtTho2PS_0+FDDRprtTho2PS_1 jointed by string.

Jointing

mode:

FDDRprtTho2PS_0: Idle
FDDRprtTho2PS_1: Packet transmission

D-24
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix D Relationship between Parameter Interface and Database Value

D.5.6 UTRAN Handover Control Parameters


l

UTRAN handover (ServiceHo)


Interface value

Database Value

Handover to UTRAN first

Not handover to UTRAN first

Not allow to handover to UTRAN

According to MSC, default handover to UTRAN


first

According to MSC, default not handover to


UTRAN first

According to MSC, default not allowed to handover to UTRAN

FDD/TDD handover (FDDTDDPrio)


Interface value

Database value

Priority to FDD

Handover to TDD cell is preferred.

D.5.7 Adjacent Cell Handover and Reselection Parameters


l

Neighboring cell layer (NCellLayer)


Interface value

Database Value

Undefined

Same layer as current cell

Upper layer of current cell

Lower layer of current cell

D.5.8 Adjacent Cell Handover Parameters


l

Neighboring cell layer (NCellLayer)


Interface value

Database Value

Undefined

Same layer as current cell

Upper layer of current cell

Lower layer of current cell

3
D-25

SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

D.5.9 Frequency Hopping System Parameters


l

Frequency hopping mode (FreqHopMode)


Interface value

Database value

Base band freqhop

RFID freqhop

D-26
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Appendix E

Mutex Right Management


Table of Contents
Applying for the Mutex Right................................................................................... E-1
Releasing the Mutex Right...................................................................................... E-1

E.1 Applying for the Mutex Right


This section describes how to apply for the mutex right on an BSC managed element. After
obtaining the mutex right, you can perform operations on this BSC managed element and
all its child nodes, such as creating, modifying, and deleting a node. The mutex right can
prevent the other users from configuring the BSC at the same time, which may result in
data confusion.

Steps
1. Right-click BSC Managed Element, and select Apply Mutex Right in the displayed
menu.
2. The Information dialog box is displayed, click Yes, and the mutex right is successfully
acquired.
End of Steps

Result
The icon appears on the configuration resource tree, as shown in . Then, the toolbutton
is enabled, and you can modify the configuration data of this managed element.
Figure E-1 Applying Mutex Right Successfully

E.2 Releasing the Mutex Right


This section describes how to release the mutex right.
A user must release the mutex right on an RNC managed element after modifying the
configuration data of the BSC via a client. Or else, the other users cannot apply for the
E-1
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

ZXG10 iBSC Radio Parameter Reference

mutex right on this BSC managed element, and thus cannot perform operations on this
BSC.
After the mutex right is released, the green lock icon before the BSC managed element
node disappears, which indicates that no one has obtained the mutex right on the BSC
managed element.

Steps
1. Right-click on BSC Managed Element and select Release Mutex Right in the
displayed menu.
End of Steps

E-2
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Figures
Figure 1-1 Starting NE Agent .................................................................................... 1-3
Figure 1-2 Configuration Management tab ................................................................ 1-4
Figure 1-3 Selecting Export Network Plan Data ...................................................... 1-5
Figure 1-4 Selecting MOC to Be Exported ................................................................ 1-5
Figure 1-5 Selecting Attributes to Be Exported for MOC............................................ 1-6
Figure 1-6 Selecting File Type to Be Exported .......................................................... 1-6
Figure 1-7 Parameter Data ....................................................................................... 1-6
Figure 1-8 Selecting Batch Apply Network Plan Data............................................. 1-8
Figure 1-9 Selecting File Type to Be Imported........................................................... 1-9
Figure 1-10 Applying Network Planning Data in Batch .............................................. 1-9
Figure E-1 Applying Mutex Right Successfully ..........................................................E-1

I
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Figures

This page intentionally left blank.

II
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Tables
Table 1-1 Format to Explain Radio Parameters ....................................................... 1-10

III
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Tables

This page intentionally left blank.

IV
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

Glossary
3GPP
- 3rd Generation Partnership Project
GERAN
- GSM/EDGE Radio Access Network
GSM
- Global System for Mobile Communications

V
SJ-20110531095035-017|2012-09-07 (R1.5)

ZTE Proprietary and Confidential

You might also like