You are on page 1of 6
PEB - Key Elements PEB - Concept to Finish Design Codes Design is done as per AMERICAN & INDIAN STANDARDS, DESIGN CODE AISC/MBMA (American) © Loads are applied in accordance with ‘The 2005 Edition of Low Building Systers Manual Metal Building Manufacturers Association (MEMA} 2 Hot rolled and Built up sections are designed in accordance with Manual of Steel Canstruction, 9 Exltion ‘American Institute of Stae| Construction (AISC) 2 Cokiformed members are designed in accordance with ‘19196 Edition of Cold Framed Staal Design Manual ‘American Institute of Steel Construction (AISC) 2 Welding is applied in accordance with ‘American Welding Society [AWS D1.198) ‘Structural Welding Cade-Stee! DESIGN CODE IS (INDIAN) © Loads are applied in accordance with : 1S 875 Part |: Code of Practice for Design Dead Loads for Building and Structures 1S 875 Partil: Code of Practice for Design Imposed Loads for Building and Structures 15875 Partill: Code of Practice for Design Wind Loads for Building ‘and Structures 15-1893 (2002) : Criteria for Earthquake Resistance Design of Structures. © Hotrrolled and Built up sections are designed in accordance with IS ~ 800 (1984): Code of Practice for General Construction in Steel IS ~ BOD (2007): Code of Practice for General Construction in Steet Latest Revision 9 Coldformed members are designed in accordance with IS ~ 801 (1975): Code of Practice for use of Cold Formed Light Gauge Steel Structure © Welding is applied in accordance with IS - 816 (1989): Code of Practice for use of Metal Arc Welding for General Construction 10 9001 comPaNY 2 LIVE THE FUTURE Primary Framing Systems ‘CLEAR SPAN (CS) SINGLE SLOPE ($5) MULTI- GABLE (Ma) Crane Systems When a crane system is required in a Lioyds Structural Steel buings, we, normaly supply column or reer brackets and the crane runway beams that support the erane system, We design the crane system after understanding the complete requirements ofthe customer. ‘TOP RUNNING CRANE posi et LUNDERHUNG CRANE [MONORAIL CRANE Mezzanine Systems The standard Sveel mezzanine framing system consists of a steel deck supported by joists framed onto main mezzanine beams, I required by design loads, the main beams shall also be supported by intermediate columns. The top flange of the joists fits immediately below the top flange ofthe primary beams. ‘The economy af a mezzanine system is affected by the applied loads (dead, live and collateral] and mezzanine column spacing, ‘Wherever possible, the primary mezzanine beams should run across the width of the building end be located under the main frame rafters, Joists should run parallel te the roof purins along the length ofthe building TPIGSL 2 SECTION TYPICAL RAFTER ‘TYPICAL COLUMN (ALL iva) {ACL Gin Secondary Members Primary Built-up Members: ( Minimurn Yield Strength is 345 KN/ cm) Liwininen Yield Sint is 345 KN/cm!) Accessories Fixed Lower Window Roof Skylight Power Ventilator Insulation Sliding Door Adjustable Louver Ridge Ventilator Turbo Ventilators: Rollup Door

You might also like