Quick Installation Sheet

System Controller (SC-450)


Quick Installation Sheet
Step 1: Unpacking
Unpack the unit and verify the following items are included:
P/N

Description

705004801

Dry Contact Alarm Output Cable, DB-15 to


Screw Terminal

705005001

Slave Controller RS-232 Connection Cable, DB-9


to RJ-45

705900003

2X Ethernet/RS-485 Communication Cable, REJ45 to RJ-45

705A000101

Dry Contact Alarm Input Cable. DB-26 to Open


Leads

255760003

Bare Wire Power Connector

255760003

705005001

705900003

705004801

705A000101

Step 2: Connect Power


Connect the DC power to the Controller PWR connector;
36 to 60VDC, 0.2A max

Step 3: Connect Base Units and RIUs


Connect RIUs and BUs to ports 1 16. Ports 9 to 16 can each be
software configured to support Slave Controllers. See Step-7.

Step 4: Auxiliary Alarms and Alarm Output


Connections
Connect the Auxiliary Alarms and Alarm Output connections on
the SC-450 rear panel according to the instructions given in the
SC-450 User Manual. See Step-12 for access to the document.

Step 5: Installations with Slave Controllers


Connect the RS232 front panel connector of each (SC-450 or
410) Slave controller to the RS232/RS485 rear panel
connector of the SC-450 Master controller.

NOTE: It is required to configure ports 9-16 to which Slave


controllers have been connected. See Step-9.

QIS_SC450_709C004204_Rev A00_07SEP11

Step-6. Installations with the 330


Refer to the 330 User Manual for more information.
For connection to Remote controllers:
At Main site, connect SC-450 ports 9 to 16 (configured as slave
ports) to the 330 Main COM 1/2.
At Remote site, connect the Slave Controller to the 330
Remote COM port.

For connection to a single Remote Base Unit:


At Main site, connect SC-450 ports 1 to 16 to the 330 Main
COM 1/2.
At Remote site, connect the 330 Remote to the Base Unit COM
port.

Step 7: Configure your Computer for a Local Setup


Connection to SC-450

2. Select Internet Protocol (TCP/IP)


Connection and choose Properties.

Configure your computer for Static IP address connection. NOTE:

3. Select Use the following IP Address, and


set the parameters as follows:

The procedure may differ depending on your operating system.


1. Right-click your Windows Local Area Connections icon
and choose Properties.

IP Address: 10.0.0.x (x = 2 to 254)


Subnet Mask: 255.255.255.0

Step 8: Open a Local WEB GUI Session to the SC-450


NOTE: The SC-450 has been optimized for use on IE 7.0, IE 9.0,
Firefox 3.0 or later and Google Chrome. For proper display on IE
8.0 use compatibility mode by selecting Tools -> Compatibility
View Options, and Add the SC-450 web-site 10.0.0.1.

2. On your computer, launch a standard


Browser (i.e. Explorer) and type the SC-450
IP address (10.0.0.1) in the address bar.

1. Connect a computer (i.e. laptop) to the SC-450 LOCAL port


via the supplied Ethernet cable (705900003).

WARNING: Do NOT connect the SC-450 LOCAL port to


a network as its DHCP server can disrupt LAN IP
addressing.

QIS_SC450_709C004204_Rev A00_07SEP11

3. The SC-450 Controller Login window appears.


Type the User Name engineer and the
default Password eng (case sensitive).
4. The SC-450 Web Management application
window appears.

Step 9: To Configure the Slave Controllers


1. In the Network Topology
tree, select the SC-450
controller to which Slaves
are (will be) connected.

2. In the Slave Mask pane, click the Modify


button and select Slave for ports (9 to 16) to
which Slave controllers are or will be
connected.

NOTE: To reset the port for RIU or BU


connection, select the Device option.

3. Click OK. The Slave controllers appear in the


Network Topology along with the devices
under their control.

Step 10: Configuring Local/LAN IP Address (Optional)


1. Click the Management tab.
2. Click IP Settings sub-menu.
3. Click the Modify button (in the Local or LAN port area) and
set the IP values.

Step 11: Connect to the Ethernet Network


Connect the SC-450 front panel LAN connector to the Ethernet
network.

Step 12: Accessing the Full Installation and


Configuration Guide
In the SC-450 GUI click on the Help tab and the SC-450 User
Manual will be displayed.