You are on page 1of 4
TAXINSINEN AAJIYA JETRIB METAL ROOFING SYSTEM TRAPEZOIDAL PROFILE AAJIYA AJIYA JET RIB INDUSTRIAL PROFILE METAL ROOFING + Roll - forming long length high tensile metal decking, + Manufactured from high tensile steel substrate protected with corrosion inhibitive treatment. + Roofing and walling profiles with material warranty up to 25 years*. “Warranty terms & conditions apply * With effective cover width of 720mm and rib height of 23mm. + For minimum roof pitch of 3° + Innovative, durable and cost effective. + Widely used for commercial and industrial projects such as factories, condominium, cabin, hoarding, and etc, SECTIONAL PROFILE LY. IV ht Dimensions Tolerence Rib height 23mm Thickness for material: +0,03mm Effective eover 20mm Effective Width +3mm Minimum roof piteh Finishing Length: + Smm. INSTALLATION MISITEKOD It is strongly recommended that AJTYA JET RIB are laid with the side laps facing away from the direction of the prevailing wind. Where possible, the roof sheets should be fixed with the side ann atils soemmmonl some omuloe oxcentne laps facing away from the mormal line street we inant ‘iuwmumaron Neve 335 of sight SIDE LAP fasteners are required at mid. spans for purlin spacings over 1,000mm and fo girt spacings over 1,200mm for all side lap and flashing rwawacrowus fastening, use no. 10 x 2Smm_ self Chmnvzemn drilling Hexagon Head Screw with pre-assembled neoprene bonded steel washer. END LAP AIIYA JET RIB is available in continuous length limited only by the maximum transportable length of 20m. For longer length, end lap is necessary. Minimum end lap should be 200mm and for roof pitches below 8°, the lap should be treated with a recommended sealant. Hi Tensile Metal Roofing Sheets in pre-painted hot-dipped zine-coated steel OR pr hot-dipped zinc-aluminium alloy-coated steel to be fixes with/without insulation, and come complete with necessary fittings and TECHNICAL SPECIFICATIONS AVAILABLE THICKNESS 0.35 0.40 2.65 3.68 272 ASTM A446-E 550 0.42 0.48 3.18 4.42 315 ASTM A446-£ 550 0.48 0.55 3.61 5.01 200 ASTM A446-E 550 035 040 130 1700 1900 2400 oa 048 1700 2100 2200 2600 08 05 2700 2700 2600 2500 RECOMMENDED MAXIMUM ROOF LENGTH (M) RAINFALL (mm/h) 150 50 60 80 200 39 50 60 250 30 40 48 300 26 30 40 The recommended minimum fall is 3°, However it must be temembered that the amount of water that must be \gth of the roof. Therefore, to avoid possible back up of water in serve wind conditions recommended roof length should be considered as maximum for a given roof pitch and rainfall IEDXIING: Vana onl sh CREST FIXING OF AJIYA JET RIB Crest fixing to st Crest fixing to timber NII ANSIPAND AR DICARPIUNG/BIEAS HING RIDGE CAPPING TYPE 24 Ve www.ajiya.com Corporate Head Office & Facto rac en ea Jalan Genuang Ceres ecu mes) Ce Derr aerated Reese ee er ge) Seksyen 32 A ec corral FLASHING TYPE 12a ee Ree tetrad Tas eee) 81400 Senai, Johor cee Le FLASHING TYPE 18b FLASHING TYPE 12b eee ; Dee etc 7 eer "PE Se ea ag ee = coe ee) ante eeRELET FASCIA/BARGE CAPPING TYPE 18 FASCIA/BARGE CAPPING TYPE 12 Deanery ND a eee Peruri e ae er en ec cere) Pecos) PO CULE eet CORNER CAPPING TYPE 9E CORNER CAPPING TYPE 91 ere near tac a So Ea Coens a+ . cl ai cert 5 [eae e ete) CC areas Lot 1306, Kawasan Perindustrian ered VALLEY TRAY TYPE 24 VALLEY TRAY TYPE 18 Laas dar r al came Sey TY : COMMITMENT tip Recon cel kde 1s) wv

You might also like