You are on page 1of 1

SelectioncriteriaforDPrangeoforificeplate

Thepastpracticefororificeplates,inpipesthatarecorrectlysized,thatIusehasbeen20"H2O
(508mmH2O)to400"H2O(10,160mmH2O).The
preferenceis100"H2O(2500mmH2O)sothatthepressuredropisreasonableandflowcanbe
halvedordoubledwithin20to400"H2O.Lowerrangevaluesmaysaveenergycosts.Rangevalues
largerthan400"H2Omayrequireathickerorificeplatetomaintainflatness.
TheselectionofDPaffectsthecalculatedboreandBetaRatio.TheselectedDPshouldresultina
BetaRatiowithin0.2and0.6forbestaccuracyofcalculateddischargecoefficient.ISO51672states
arangeof0.1to0.75withdifferentaccuracyformulasforBetaRatioranges.
Ingasorvaporservicetheselecteddifferentialpressureisusedtocalculatethegasexpansionfactor.
TheruleofthumbthatIuseistokeeptheDPvalueininchesofwaternogreaterthanthestatic
pressureinPSIG.

AGA 3 Appendix 2-F provides guidelines for using high differential for
flow measurement of natural gas.

You might also like