You are on page 1of 100

CABLE LADDERS

www.meka.net

2004

MEKA
Meka is a Finnish company whose business idea is to produce high-quality and competitive cable support
systems for the various construction projects of our customers.
Meka cable support systems are manufactured from high quality raw materials. We operate on all levels based
on the principles of sustainable development of the environment. All Meka products are technically tested and
meet the given technical specifications.
Designing of Meka products is focused on easy installation facilitated by versatile installation components. This
ensures the high quality and applicability of products even in the most demanding environments.
Using Mekas cable support systems is a modern way of electrifying different buildings and spaces easily and
economically.
Meka has ISO 9001 Quality System Certificate which is valid for product development, manufacturing and
marketing.

PRODUCT RANGE
Cable ladders
KS20, KS30 and KS35 cable ladders - made of hot galvanised metal sheet, coating thickness approx. 20 m of
zinc. Can be used in offices, shops, schools, hospitals, warehouses and industrial spaces (environment
classification C1 and C2).
KS80, KSE80 and KSF80 tube type cable ladders. Hot dip galvanised after manufacture, coating thickness
approx. 60 m of zinc. Can be used for industrial applications where high and concentrated load carrying
capacity, lateral rigidity and a durable surface finishing are required. These include: industrial building sites,
power plants, food, pharmaceutical and animal feed industry, humid areas and tunnels etc. industrial areas
(environment classification C1, C2, C3 and C4).
RST and HST - stainless steel and acid-proof cable ladders can be used in chemical and wood processing
industry as well as in other highly corrosive environments. Other places of use are places where hygiene is a vital
factor, such as in dairies, slaughter-houses, other areas of food industry and pharmaceutical plants, tunnels etc.
PEX tube type cable ladders. Hot dip galvanised after manufacture (coating thickness approx. 60 m of zinc),
powder painted and finally hardened in an oven. Can be used in industrial areas with high humidity and harsh
atmosphere coastal or offshore areas (environment classification C5-I and C5-M).
Cable trays and lighting tracks
KRA, KRB, KRC and KRV - smooth and perforated cable trays with different height of border: 12, 40, 60, 80 and
110 mm.
MEK 70 and MEK 110 - lighting tracks with special groove for sliding nuts.
Cable trays and lighting tracks are made of hot galvanised sheet metal or hot galvanised and coil coated sheet
metal. The standard colour in coil coated products is white (RAL 9010, NCS 0502-Y), other colours are available
on request.
Cable trays KR and lighting tracks MEK are used in office buildings, business locations, shopping centres,
schools and other public buildings in which the cable trays are an integral part of the interior (environment
classification C1 and C2).
(Environment classifications according to SFS-EN ISO 12944-2 standard.)
Cable trunkings and socket poles
INSTAL cable trunkings and INSTAL SP socket poles are used in electrical installations where the design and
appearance are an integral and important part of the interior.
Main applications are offices, public buildings, business locations, schools and hospitals.
INSTAL products are made of aluminium and painted white (RAL 9010) or grey (RAL 9006), or anodised, in
which case they retain their natural metal tone. Products painted in other colours could be available on request.
Nearly all possible mounting boxes can be used in connection with the INSTAL trunkings and socket poles, which
mean that the fixtures suitable for any given environment can be chosen freely.

Address: Meka MekaJohtotiet Oy, Konetie 25, 90630 Oulu, Finland;


Tel. +358 8 5313100, Telefax +358 8 5313150; www.meka.net e-mail: meka@meka.net

3.

CHOOSING THE CABLE LADDER TYPE

Choosing environment classification

C1 and C2

C3 and C4

Choose type of cable ladder


according to load

KS20/KS30

KS80, KSE80

C5-I and C5-M

Choose type of cable ladder


according to load

KSF80

PEX KS80

PEX KSF80

Choose type of cable ladder


according to load

HST/RST KS80

HST KSF80

The choice of surface treatment are made according to factors


effecting the product in the surrounding environment,
as set out in the SFS-EN ISO 12944-2 standard

Address: Meka MekaJohtotiet Oy, Konetie 25, 90630 Oulu, Finland;


Tel. +358 8 5313100, Telefax +358 8 5313150; www.meka.net e-mail: meka@meka.net

4.

CORROSION CLASSIFICATION

The choice of surface treatment are made according to factors effecting the product in the
surrounding environment, as specified in the SFS-EN ISO 12944-2 standard.
Corrosivity
category

Examples of typical environments in a temperate


climate (informative only)
Exterior

C1
very low

C2
low

C3
medium

C4
high

Interior

Heated buildings with


clean atmospheres, e.g.
offices, shops, schools,
hotels.
Atmospheres with low
Unheated buildings
level of pollution. Mostly where condensation may
rural areas.
occur, e.g. warehouses,
sport halls.
Urban and industrial
Production rooms with
atmospheres, moderate high humidity and some
sulphur dioxide pollution. air pollution, e.g. foodCoastal areas with low
processing plants,
salinity.
laundries, breweries,
dairies.
Industrial areas and
Chemical plants,
coastal areas with
swimming pools, coastal
moderate salinity.
ship- and boatyards.

C5-I
Industrial areas with high Buildings or areas with
very high humidity and harsh
almost permanent
(industrial) atmosphere.
condensation and with
high pollution.
C5-M
very high
(marine)

Coastal and offshore


areas with high salinity.

Surface treatment required

Buildings or areas with


almost permanent
condensation and with
high pollution.

Hot galvanised sheet metal,


or plastic coated sheet
metal.
Hot galvanised sheet metal,
or plastic coated sheet
metal.
Hot galvanisation after
assembly.

Hot galvanisation after


assembly.
Hot galvanisation and epoxy
painting after assembly.
Acid-proof steel.
Surface treatment chosen
case-by-case.
Hot galvanisation and epoxy
painting after assembly.
Acid-proof steel.
Surface treatment chosen
case-by-case.

Notes:
1. The loss values used for the corrosivity categories are identical to those
given in ISO 9223.
2. In coastal areas in hot, humid zones, the mass or thickness losses can
exceed the limits of category C5-M. Special precautions must therefore be
taken when selecting protective paint systems for structures in such areas.

Address: Meka MekaJohtotiet Oy, Konetie 25, 90630 Oulu, Finland;


Tel. +358 8 5313100, Telefax +358 8 5313150; www.meka.net e-mail: meka@meka.net

5.

SURFACE TREATMENTS
Hot galvanised steel sheet
Sheet metal is hot galvanised on continuously moving production lines. The basic material
is cold-rolled steel sheeting. After degreasing, the sheet is pickled and oxidised, after which
surface oxides are removed by a reduction in temperature to 950C, which also
simultaneously softens the steel. The surface of the sheet is now purified metal and is
transferred directly into a zinc bath. The sheet is then vertically driven out of the bath
between air jets, to remove excess zinc from the surface of the sheet while the zinc goes
back into the bath, leaving the desired coating. Computerised measurement systems are
used to measure the thickness of the coating, while the operation of the air jets is also
computerised. After cooling, straightening and white rust prevention treatment, the sheet is
either delivered to the cutting press, rolled, or transferred to the plastic coating line.
MekaJohtotiet Oy produces KS20 and KS30 cable ladders, MEK lighting tracks, and KRA,
KRB, KRC cable trays from hot galvanised sheet metal. These products include a coating
thickness of approximately 20 m of zinc. They are suitable for installation in dry
environments, such as in offices, shops, hospitals, factories etc.
The hot galvanised steel sheet used by MekaJohtotiet Oy is galvanised according to the
SFS-EN 10142 standard, which is equal to the ASTM A 653 standard, and the old SS
141151 and DIN 17162 standards.
Hot galvanising by immersion
Grease, oil, and soot are usually removed using an alkaline degreasing solution. After
flushing with water rust and rolling scale are removed from the surfaces by pickling the steel
in diluted hydrochloric acid or sulphuric acid. Prior to the sheet being immersed in molten
zinc, it has to be treated with a fluidiser, to remove oxides from the surfaces of both the
steel sheet and the bath in order to allow the steel and zinc to form a metallic bond between
each other. After the fluidised bath treatment, the substrates are dried. A thin layer of
fluidiser salt is left on the surfaces of the objects. After this, the object is immersed in the
zinc, after which it is ready for final cleaning, inspection and loading. Mekajohtotiet Oy hot
galvanises all cable ladders KS80, KSE80, KSF80 and their installation accessories using
this method, according to the SFS-EN 1461 standard, which corresponds to the old SFS 2765
and DIN 50976 standards.
These products include a coating thickness of approximately 60 m of zinc.
Duplex treatment
Hot galvanisation usually provides more than adequate protection against corrosion.
In some cases however, additional protection may be needed if the environment is
exceptionally corrosive. Duplex treatment gives the customer lasting protection against
corrosion and in addition, the opportunity to choose a colour to go with the rest of the
interior.
The zinc surface must be thoroughly cleaned before painting in order to ensure good
adhesion, and an appropriate paint type must be used. After careful preparation, cable
ladders and accessories are powder painted and finally hardened in an oven. MekaJohtotiet
Oys cable ladder system PEX is Duplex treated.

6.
Address: Meka MekaJohtotiet Oy, Konetie 25, 90630 Oulu, Finland;
Tel. +358 8 5313100, Telefax +358 8 5313150; www.meka.net e-mail: meka@meka.net

INSTALLATION INSTRUCTIONS
TECHNICAL REQUIREMENTS
Before using the cable trays, please read the following standards and regulations and the installation
instructions in the product folder:
1. Standard SFS 3209 "Switchboard and telecommunications spaces, cable conduits" contains
instructions for measuring the area needed for cable trays.
2. ST card ST 51.13 "Cable trays, ladders and track lighting".
3. ST card ST 841.05 "Layouts for cable trays"
4. ST cards ST 51.91 and ST 841.10 present the ways in which ducts are made.
5. ST card ST 13.51 presents the CAD graphic symbols of cable trays.
GENERAL INSTALLATION INSTRUCTIONS
Installation is performed in a way that deflection does not exceed 1/200 in visible cable trays and
lighting tracks. In industrial and hidden cable trays and lighting tracks deflection must not exceed
1/100. An additional allowance of approx. 50% of the existing load must be included when
calculating deflection.
Sufficient room for heat expansion must be left at the ends and between cable trays and lighting
tracks. The heat expansion coefficient of steel is 0.000012 m/C.
Cable trays and lighting tracks are fixed in a manner which does not allow them to slant or twist
laterally.
The load bearing capacity of brackets and the strength of fixing and surface materials must be taken
into consideration as cable trays and lighting tracks are installed.
In places where vertical trays are subject to physical damage, they should be protected up to a
height of 1.5 m with a protective cover.
Ducts
When cable trays pass a fire-wall they must be cut. At borders of fire areas, the ducts must
correspond to the fire endurance of the material being cut through. Different fire-proof cable ducts
are presented in ST card 51.18.
The principles of sound insulation in connection with cable trays and lighting tracks passing
through walls are presented in ST card 51.19.
Cables
Insulated cables are the most common cables used. External factors such as heat must be considered
as cables are installed. Similarly, the effect of the strongest continuous current on the temperature of
the cable must be taken into consideration. On a horizontal tray, cables are usually placed neatly
straightened without fastening. On vertical and slanting trays, cables are fastened to the tray at
appropriate distances with suitable fasteners.
Accessories
Accessories, such as branch boxes, which are installed on cable trays or lighting tracks are to be
fastened firmly and in such a manner that they do not obstruct the actual cable space. Mountings,
supports and other accessories are used when needed.
Electrical conductivity of cable ladders
All of MekaJohtotiet Oy cable ladders, cable trays and lighting tracks have been tested for electrical
conductivity in Sweden at SP (Swedish National Testing and Research Institute). If you would like
to obtain the test results, contact MekaJohtotiet Oys technical support staff.
Address: Meka MekaJohtotiet Oy, Konetie 25, 90630 Oulu, Finland;
Tel. +358 8 5313100, Telefax +358 8 5313150; www.meka.net e-mail: meka@meka.net

7.

USAGE OF CABLE LADDERS


KS20/KS30 -cable ladders system can be used within environmental stress classifications
C1 and C2 common applications include offices, shops, schools, hospitals, warehouses
and industrial spaces.
KS80 cable ladder system can be used for industrial applications where high and
concentrated load carrying capacity, lateral rigidity and a durable surface finishing are
required. These include industrial building sites, power plans, food, pharmaceutical and
animal feed industries, humid areas and tunnels.
KSF80 cable ladder system can be used for industrial applications where high and
concentrated load carrying capacity, lateral rigidity and durable surface finishing are
required.
KSE80 cable ladders are manufactured to use in food processing industry, mainly.

TO BE TAKEN INTO CONSIDERATION


1. Cable ladders and cable trays are intended only for supporting cables.
2. As cable ladders and other conduit products are installed, the load carrying capacity of
brackets is to be observed, and care should be taken to see that there is sufficient
strength in the fixtures and surface materials.
3. Cable trays must not be used as ladders or walk-ways.
4. The manufacturer is not responsible for direct or indirect damages caused by inappropriate
use of any of our products.

Address: Meka MekaJohtotiet Oy, Konetie 25, 90630 Oulu, Finland;


Tel. +358 8 5313100, Telefax +358 8 5313150; www.meka.net e-mail: meka@meka.net

8.

KS 20

GT 10
GT 16

NL/KS20

KK/KS20

VF

KK/KS20
VK

SSR/KS20

RTF-10/KS20

PRT/KS20
NL/KS20

KK/KS20

KS20
SSC/KS20

HK13/KS20
VKI/KS20
VK2/KS20

KS20

KK-MK/KS20

MK/KS20
F

10-11.

KS 80
HK1
HK2

SK
ST

POL

SB

KL

SSR

AP

KAP

AG

TP1
JK

DPB
KS90

FP-2000

KST
KK

TP2

RTF-10

TFP

DPA

SSU

TPK

ASR

KSV
VKF

RTF-S

ASR-TF
KSX
FM

VF
SR

VK2

KS80

VK

SP

SK
KL

KS80
RTF-Z

PSK

GT10
NL

KK13

PK1
PK2

SMT

AKM
TB

NL-TK

VEF2
HK13

12-13.

KSF 80
SSA/KSF80

VFF/KSF80
KS90/KSF

VKF

KKF

KSF-VT/KSF80

KSF80
Bolt set KSF
KSF-NL

KSF80

14-15.

CABLE LADDERS

Cable ladders KS20, KS30 and KS35


15

11x15

27
60
25
250
B

21

A
11

15

29

Product

SSTL Package Weight kg A mm


number
m
/100m

B mm

Length
m

Hot galvanised sheet metal


KS20-200
KS20-300
KS20-400
KS20-500
KS20-600

14 495 02
14 495 03
14 495 04
14 495 05
14 495 06

60
60
60
60
60

212
232
252
272
292

197
297
397
497
597

167
267
367
467
567

6
6
6
6
6

14 495 12
14 495 13
14 495 14
14 495 15
14 495 16

40
40
40
40
40

212
232
252
272
292

197
297
397
497
597

167
267
367
467
567

4
4
4
4
4

60
60
60
60
60

212
232
252
272
292

197
297
397
497
597

167
267
367
467
567

6
6
6
6
6

14 311 12
14 311 13
14 311 14
14 311 15
14 311 16

40
40
40
40
40

212
232
252
272
292

197
297
397
497
597

167
267
367
467
567

4
4
4
4
4

14 494 01
14 494 02
14 494 03
14 494 04
14 494 05

30
30
30
30
30

212
232
252
272
292

197
297
397
497
597

167
267
367
467
567

3
3
3
3
3

Hot galvanised sheet metal


KS30-200
KS30-300
KS30-400
KS30-500
KS30-600

Hot galvanised and painted sheet metal


PEX KS20-200
PEX KS20-300
PEX KS20-400
PEX KS20-500
PEX KS20-600

14 311 02
14 311 03
14 311 04
14 311 05
14 311 06

Hot galvanised and painted sheet metal


PEX KS30-200
PEX KS30-300
PEX KS30-400
PEX KS30-500
PEX KS30-600
Hot galvanised sheet metal
KS35-200
KS35-300
KS35-400
KS35-500
KS35-600

16.

CABLE LADDERS

Construction

Application

The KS20/KS30 cable ladder systems is made from hot


galvanised sheet metal. The thickness of the zinc coating is
at least 20 m. If required, the products can be painted with
a colour chosen by the customer. The lateral section of the
cable ladder is 60 mm high, which ensures a good load
carrying capacity. Since the rungs are perforated, fastening
cables onto the ladder is easy. The same installation parts are
suitable for use with all MEKA cable ladder systems. The
MEKA KS20 cable ladder is delivered in 6 metre sections and
the KS30 cable ladder in 4 metre sections. Other lengths
varying from 3 to 6 metres are also available.

The MEKA KS20/KS30 cable ladders system can


be used within environmental stress classifications C1
and C2 common applications include:
offices
shops
schools
hospitals
warehouses
industrial spaces
Load carrying capacity
Choose the bearing distance using load curves below:

Load curves
Case 2
Bearing distance of end space 0.8 L

Case 1
Bearing at equal distances
F1

F2

F1

Fmax

Fmax

Fmax

Fmax

f1

f2

E
f1

Fmax
E

fmax

fmax

fmax

fmax

fmax

0,8 L

q
B

0,8 L

Bearing distance of spaces A and E is 0.8 L. Other spaces are of even lengths L.

Bearing at equal distances

20

L=4,0 m L=3,5 m

KS20 and KS30

Bearing distance
of end space 0.8 x L KS20 and KS30

Safety factor 2.0

L=3,0 m

10

L=4,0 m

20

L=3,5 m

10

20

40

60

80

100

120

140

0
160

even load q, kg/m

Deflection f(max.),mm

L=2,0 m
5

Deflection f2, mm

Deflection f1, mm

L=2,5 m
15

Safety factor 2,0

15
L=3,0 m
10

L=2,5 m
L=2,0 m

20

40

60

80

100

120

140

160

even load q, kg/m

Explanation of the cable ladder load


curves
A five-span load-bearing beam is illustrated above (Case 1), in which
the deflection f1 is measured in spans A and E. In long installations,
the deflection is demostrated by f2. If the end of the ladder is securely
fastened to the wall then, where the ladder begins, deflection f2 is used.
If there is no end attachment, and if the load is at equal distances, the
deflection of spans A and E can be measured at f1, and the deflection
of other spans, at f2. If the end of the ladder is not attached to the wall,
and the deflection is to be decreased (Case 2), the bearing distance for

spans A and E must be reduced by 20%, ie. 0.8 x L (L = bearing load


at equal distances), in which case the load corresponds to the load in
Case 2. The maximum deflection in each support span in Case 2 is
demonstrated in Table 2. Deflection is also influenced by the type of the
extensions which are used and by the method used to support the
extensions. The value at the end of each load curve represents the
maximum permitted load (safety factor 2), which must not be exceeded.

17.

CABLE LADDERS

Industrial cable ladders KS80 and KS85


15

60

11x15
42
25

250

21
B
11
A

Product

SSTL Package
number
m

15

29

Weight kg A mm
/100 m

B mm Length
m

Hot dip galvanised after manufacture


KS80-150
KS80-200
KS80-300
KS80-400
KS80-500
KS80-600
KS80-1000

14 495 21
14 495 22
14 495 23
14 495 24
14 495 25
14 495 26
14 495 30

60
60
60
60
60
60
60

270
280
300
320
340
360
450

150
200
300
400
500
600
1000

120
170
270
370
470
570
970

6
6
6
6
6
6
6

60
60
60
60
60
60
60

270
280
300
320
340
360
450

150
200
300
400
500
600
1000

120
170
270
370
470
570
970

6
6
6
6
6
6
6

60
60
60
60
60

470
490
510
530
550

200
300
400
500
600

170
270
370
470
570

6
6
6
6
6

270
280
300
320
340
360

150
200
300
400
500
600

120
170
270
370
470
570

3
3
3
3
3
3

Hot dip galvanised and painted after manufacture


PEX KS80-150
PEX KS80-200
PEX KS80-300
PEX KS80-400
PEX KS80-500
PEX KS80-600
PEX KS80-1000

14 306 01
14 306 02
14 306 03
14 306 04
14 306 05
14 306 06
14 306 10

Hot dip galvanised after manufacture


KS80-200 SP2.0
KS80-300 SP2.0
KS80-400 SP2.0
KS80-500 SP2.0
KS80-600 SP2.0

14 495 07
14 495 08
14 495 09
14 495 10
14 495 11

Hot dip galvanised after manufacture


KS85-150
KS85-200
KS85-300
KS85-400
KS85-500
KS85-600

14 494 06
14 494 07
14 494 08
14 494 09
14 494 10
14 494 11

30
30
30
30
30
30

18.

CABLE LADDERS
Construction

Applications

The KS80 cable ladder system is made from high quality


steel. The products are zinc coated by immersion after
manufacture. The thickness of the zinc coating is at least 55
m. The PEX cable ladder system is DUPLEX coated on top
of the zinc layer. DUPLEX coated products are normally white
(RAL 9010). If required, the products can be painted with a
colour chosen by the customer. The lateral section of the
ladder is 60 mm high, which ensures a good load carrying
capacity. Since the rungs are perforated, fastening cables
onto the tray is easy. All MEKA cable ladder systems can be
used with the same installation accessories. The MEKA KS80
cable ladder is delivered in 6 metre sections.

The MEKA KS80 cable ladder system can be used in


environmental stress classifications C1, C2, C3, C4 and
PEX KS80 at the maximum C5-I classification.
The KS80 cable ladder system can be used for industrial
applications where high and concentrated load carrying
capacity, lateral rigidity and a durable surface finishing are
required. These include:
industrial building sites
power plants
food, pharmaceutical, and animal feed industries
humid areas
tunnels
Load carrying capacity
Choose the bearing distance using the load curves below:

Load curves
Case 2
Bearing distance of end space 0.8 L

Case 1
Bearings at equal distances
F1

F2

Fmax

Fmax

Fmax

Fmax

f1

fmax

fmax

fmax

fmax

fmax

0,8 L

F1

f1

f2

Fmax

q
B

0,8 L

Bearing distance of spaces A and E is 0.8 L. Other spaces are of even lengths L.

Bearing at equal distances

20

Safety factor 2.0

KS80

L=4,0 m L=3,5 m L=3,0 m

Bearing distance of end space 0,8 x L

20
L=3,5 m

L=2,0 m
5

50

100

150

Deflection f(max.), mm

15

Deflection f2, mm

Deflection f1, mm

L=2,5 m

0
200

15

30

L=2,5 m

L=2,0 m

0
50

100

150

200

even load q, kg/m

Bearing distance
of end space 0.8xL

Safety factor 2,0

KS80 SP 2.0

L=5,0 m L=4,5 m

L=3,0 m

10

even load q, kg/m

Bearing at equal distances

Safety factor 2.0

L=4,0 m

10

10

KS80

L=4,0 m

L=3,5 m

15

KS80 SP 2.0
L=5,0 m

30

Safety factor 2,0


L=4,5 m
L=4,0 m

10

20
15

10
5
0

Deflection f(max), mm

25

Deflection f2, mm

Deflection f1, mm

25

20
L=3,5 m
15
10
5

25
50
even load q, kg/m

75

0
100

25

50
even load q, kg/m

75

100

Explanation of the cable ladder load curves


A five-span load-bearing beam is illustrated above (Case 1), in which the
deflection f1 is measured across spans A and E. For long installations, the
deflection is demostrated by f2. If the end of the ladder is securely fastened to
the wall then, where the ladder begins, deflection f2 is used. If there is no end
attachment, and if the load is at equal distances, the deflection of spans A and
E can be measured at f1, and the deflection of other spans, at f2. If the end of
the ladder is not attached to the wall, and the deflection is to be decreased

(Case 2), the bearing distance for spans A and E must be reduced by 20%, ie.
0.8 x L (L = bearing load at equal distances), in which case the load corresponds
to the load in Case 2. The maximum deflection in each support span in Case
2 is demonstrated in Table 2. Deflection is also influenced by the type of the
extensions which are used and by the method used to support the extensions.
The value at the end of each load curve represents the maximum permitted
load (safety factor 2), which must not be exceeded.

19.

CABLE LADDERS

Industrial cable ladder KSF80


15
21

60

A
15

42

12x25

10,5

154
74

11
29

50
50
250

Product

25

SSTL Package Weight kg A mm


number
m
/100 m

11x15

100

38
73
500

B mm Length
m

Hot dip galvanised after manufacture


KSF80-200
KSF80-300
KSF80-400
KSF80-500
KSF80-600
KSF80-1000

14 495 32
14 495 33
14 495 34
14 495 35
14 495 36
14 495 40

24
24
24
24
24
24

430
450
470
490
510
600

200
300
400
500
600
1000

170
270
370
470
570
970

6
6
6
6
6
6

430
450
470
490
510
600

200
300
400
500
600
1000

170
270
370
470
570
970

6
6
6
6
6
6

Hot dip galvanised and painted after manufacture


PEX KSF80-200
PEX KSF80-300
PEX KSF80-400
PEX KSF80-500
PEX KSF80-600
PEX KSF80-1000

14 306 22
14 306 23
14 306 24
14 306 25
14 306 26
14 306 30

24
24
24
24
24
24

20.

CABLE LADDERS
Construction

Applications

The KSF80 cable ladder system is made from high quality


steel. The products are zinc coated by immersion after
manufacture. The thickness of the zinc coating is at least 55
m. The PEX cable ladder system is DUPLEX coated on top
of the zinc layer. DUPLEX coated products are normally white
(RAL 9010). If required, the products can be painted with a
colour chosen by the customer. The lateral section of the
ladder is 153 mm high, which ensures good load carrying
capacity. Since the rungs are perforated, fastening cables
onto the tray is easy. All MEKA cable ladder systems can be
used with the same installation accessories. The MEKA KSF80
cable ladder is delivered in 6 metre sections.

The MEKA KSF80 cable ladder system can be used in


environmental stress classifications C1, C2, C3, C4 and PEX
KSF80 at the maximum C5-I classification.
The KSF80 cable ladder system can be used for industrial
applications where high and concentrated load carrying
capacity, lateral rigidity and durable surface finishing are
required.
Load carrying capacity
Choose the bearing distance using the load curves below:

Load curves
Case 1
Bearing at equal distances
F1

Case 2
Bearing distance of end space 0.8 L

F2

F1

Fmax

Fmax

Fmax

Fmax

f1

f2

f1
L

Fmax
E

fmax

fmax

fmax

fmax

fmax

0,8 L

q
B

0,8 L

Bearing distance of spaces A and E is 0.8 L. Other spaces are of even lengths L.

60
L=9,0 m
L=8,0 m
40
L=7,0 m
30

L=6,0 m

20

L=5,0 m
L=4,0 m

10

0
20

40

60

80

100

120

140

160

even load q, kg/m

Deflection f(max.), mm

50

Deflection f2, mm

Deflection f1, mm

120
110
100
90
80
70
60
50
40
30
20
10

Bearing distance
of end space 0,8 x L

Safety factor 2,0

KSF80

Bearing at equal distances

60
55
50
45
40
35
30
25
20
15
10
5

Safety factor 2,0

KSF80

L=9,0 m
L=8,0 m
L=7,0 m
L=6,0 m
L=5,0 m
L=4,0 m

0
50

100
even load q, kg/m

150

200

Explanation of the cable ladder load curves


A five-span load-bearing beam is illustrated above (Case 1), in which the
deflection f1 is measured across spans A and E. For long installations, the
deflection is demostrated by f2. If the end of the ladder is securely fastened to
the wall then, where the ladder begins, deflection f2 is used. If there is no end
attachment, and if the load is at equal distances, the deflection of spans A and
E can be measured at f1, and the deflection of other spans, at f2. If the end of
the ladder is not attached to the wall, and the deflection is to be decreased

0.8 x L (L = bearing load at equal distances), in which case the load corresponds
to the load in Case 2. The maximum deflection in each support span in Case
2 is demonstrated in Table 2. Deflection is also influenced by the type of the
extensions which are used and by the method used to support the extensions.
The value at the end of each load curve represents the maximum permitted
load (safety factor 2), which must not be exceeded.

21.

BEND, T and X PIECES

Bend KS90

KS20, KS80

A
R
B

Product

Package Weight kg A mm
SSTL
pc
number
/100 pcs

B mm

RADIUS OF INSIDE ARC R=300


Hot dip galvanised after manufacture
KS90-150 R=300
KS90-200 R=300
KS90-300 R=300
KS90-400 R=300
KS90-500 R=300
KS90-600 R=300

14 495 47
14 495 48
14 495 49
14 495 50
14 495 51
14 495 52

1
1
1
1
1
1

220
240
300
330
400
450

150
200
300
400
500
600

600
650
750
850
950
1050

1
1
1
1
1
1

220
240
300
330
400
450

150
200
300
400
500
600

600
650
750
850
950
1050

1
1
1
1
1
1

330
380
410
440
560
610

150
200
300
400
500
600

885
935
1035
1135
1235
1335

330
380
410
440
560
610

150
200
300
400
500
600

885
935
1035
1135
1235
1335

Hot dip galvanised and painted after manufacture


PEX KS90-150 R=300
PEX KS90-200 R=300
PEX KS90-300 R=300
PEX KS90-400 R=300
PEX KS90-500 R=300
PEX KS90-600 R=300

14 306 51
14 306 52
14 306 53
14 306 54
14 306 55
14 306 56

RADIUS OF INSIDE ARC R=600


Hot dip galvanised after manufacture
KS90-150 R=600
KS90-200 R=600
KS90-300 R=600
KS90-400 R=600
KS90-500 R=600
KS90-600 R=600

14 495 41
14 495 42
14 495 43
14 495 44
14 495 45
14 495 46

Hot dip galvanised and painted after manufacture


PEX KS90-150 R=600
PEX KS90-200 R=600
PEX KS90-300 R=600
PEX KS90-400 R=600
PEX KS90-500 R=600
PEX KS90-600 R=600

14 306 61
14 306 62
14 306 63
14 306 64
14 306 65
14 306 66

1
1
1
1
1
1

22.

BEND 90o, T and X PIECES


Product

SSTL
Package Weight kg A mm
number
pc
/100 pcs

B mm

RADIUS OF INSIDE ARC R=1000


Hot dip galvanised after manufacture
KS90-150 R=1000
KS90-200 R=1000
KS90-300 R=1000
KS90-400 R=1000
KS90-500 R=1000
KS90-600 R=1000

14 495 53
14 495 54
14 495 55
14 495 56
14 495 57
14 495 58

1
1
1
1
1
1

429
494
533
572
728
790

150
200
300
400
500
600

1270
1320
1420
1520
1620
1720

429
494
533
572
728
790

150
200
300
400
500
600

1270
1320
1420
1520
1620
1720

Hot dip galvanised and painted after manufacture


PEX KS90-150 R=1000
PEX KS90-200 R=1000
PEX KS90-300 R=1000
PEX KS90-400 R=1000
PEX KS90-500 R=1000
PEX KS90-600 R=1000

14 306 71
14 306 72
14 306 73
14 306 74
14 306 75
14 306 76

1
1
1
1
1
1

Installation examples
Fastening bend to cable ladder

Fastening bend to cable ladder

KS90
SSR
SSU
KS90
SSU

SSR
KS80

KS80

Bend KS90 is fastened into cable ladder KS80 with


connection piece SSU.

Bend KS90 is fastened onto cable ladder KS80 with


connection piece SSR, and onto cable ladder KS20 with
connection piece SSR/KS20.

23.

BEND, T and X PIECES

Bend KS90/KSF

KSF80

A
R = 300
B

Product

SSTL
number

Package Weight kg A mm
pc
/100 pcs

B mm

RADIUS OF INSIDE ARC R=300


Hot dip galvanised after manufacture
KS90-200/KSF R=300
KS90-300/KSF R=300
KS90-400/KSF R=300
KS90-500/KSF R=300
KS90-600/KSF R=300

14 494 41
14 494 42
14 494 43
14 494 44
14 494 45

1
1
1
1
1

420
500
580
650
720

200
300
400
500
600

650
750
850
950
1050

1
1
1
1
1

420
500
580
650
720

200
300
400
500
600

650
750
850
950
1050

Hot dip galvanised and painted after manufacture


PEX KS90-200/KSF R=300
PEX KS90-300/KSF R=300
PEX KS90-400/KSF R=300
PEX KS90-500/KSF R=300
PEX KS90-600/KSF R=300

14 307 32
14 307 33
14 307 34
14 307 35
14 307 36

Installation example
Fastening bend to cable ladder
KS90/KSF
SSA

BOLT SET KSF

KSF80

Bend KS90/KSF is fastened onto cable ladder KSF80 with


connection piece SSA and bolt set KSF.

24.

BEND, T and X PIECES

Bend SB

KS20, KS80

A
R = 100
B

Product

SSTL
number

Package Weight kg A mm
pc
/100 pcs

B mm

Hot dip galvanised after manufacture


SB-200 R=100
SB-300 R=100
SB-400 R=100
SB-500 R=100
SB-600 R=100

14 495 60
14 495 61
14 495 62
14 495 63
14 495 64

1
1
1
1
1

170
200
250
300
330

200
300
400
500
600

450
550
650
750
850

170
200
250
300
330

200
300
400
500
600

450
550
650
750
850

Hot dip galvanised and painted after manufacture


PEX SB-200 R=100
PEX SB-300 R=100
PEX SB-400 R=100
PEX SB-500 R=100
PEX SB-600 R=100

14 306 82
14 306 83
14 306 84
14 306 85
14 306 86

1
1
1
1
1

Installation examples
Fastening bend to cable ladder

Fastening bend to cable ladder

SB

SB
SSR

SSU

SSR

SSU

KS80

Bend SB is fastened onto cable ladder KS80 with connection


piece SSU.

KS80

Bend SB is fastened onto cable ladder KS80 with connection


piece SSR, and onto cable ladder KS20 with connection
piece SSR/KS20.

25.

BEND, T and X PIECES

T piece KST

KS20, KS80

A
R

Product

SSTL
number

Package Weight kg A mm
pc
/100 pcs

B mm

L mm

RADIUS OF INSIDE ARC R=300


Hot dip galvanised after manufacture
KST-150 R=300
KST-200 R=300
KST-300 R=300
KST-400 R=300
KST-500 R=300
KST-600 R=300

14 495 68
14 495 69
14 495 70
14 495 71
14 495 72
14 495 73

1
1
1
1
1
1

400
440
510
580
670
700

150
200
300
400
500
600

600
650
750
850
950
1050

1050
1100
1200
1300
1400
1500

1
1
1
1
1
1

400
440
510
580
670
700

150
200
300
400
500
600

600
650
750
850
950
1050

1050
1100
1200
1300
1400
1500

1
1
1
1
1
1

660
720
797
874
950
1027

150
200
300
400
500
600

885
935
1035
1135
1235
1335

1620
1670
1770
1870
1970
2070

660
720
797
874
950
1027

150
200
300
400
500
600

885
935
1035
1135
1235
1335

1620
1670
1770
1870
1970
2070

Hot dip galvanised and painted after manufacture


PEX KST-150 R=300
PEX KST-200 R=300
PEX KST-300 R=300
PEX KST-400 R=300
PEX KST-500 R=300
PEX KST-600 R=300

14 306 91
14 306 92
14 306 93
14 306 94
14 306 95
14 306 96

RADIUS OF INSIDE ARC R=600


Hot dip galvanised after manufacture
KST-150 R=600
KST-200 R=600
KST-300 R=600
KST-400 R=600
KST-500 R=600
KST-600 R=600

14 495 82
14 495 83
14 495 84
14 495 85
14 495 86
14 495 87

Hot dip galvanised and painted after manufacture


PEX KST-150 R=600
PEX KST-200 R=600
PEX KST-300 R=600
PEX KST-400 R=600
PEX KST-500 R=600
PEX KST-600 R=600

14 307 01
14 307 02
14 307 03
14 307 04
14 307 05
14 307 06

1
1
1
1
1
1

26.

BEND, T and X PIECES


Product

SSTL
number

Package Weight kg A mm
pc
/100 pcs

B mm

L mm

RADIUS OF INSIDE ARC R=1000


Hot dip galvanised after manufacture
KST-150 R=1000
KST-200 R=1000
KST-300 R=1000
KST-400 R=1000
KST-500 R=1000
KST-600 R=1000

14 494 21
14 494 22
14 494 23
14 494 24
14 494 25
14 494 26

1
1
1
1
1
1

1056
1152
1275
1398
1520
1650

150
200
300
400
500
600

1270
1320
1420
1520
1620
1720

2390
2440
2540
2640
2740
2840

1056
1152
1275
1398
1520
1650

150
200
300
400
500
600

1270
1320
1420
1520
1620
1720

2390
2440
2540
2640
2740
2840

Hot dip galvanised and painted after manufacture


PEX KST-150 R=1000
PEX KST-200 R=1000
PEX KST-300 R=1000
PEX KST-400 R=1000
PEX KST-500 R=1000
PEX KST-600 R=1000

14 307 11
14 307 12
14 307 13
14 307 14
14 307 15
14 307 16

1
1
1
1
1
1

Installation examples
Fastening T piece to cable ladder

Fastening T piece to cable ladder


KST

KST

SSU
SSR

SSU

SSR

KS80
KS80

T piece KST is fastened onto cable ladder KS80 with connection


piece SSU.

T piece KST is fastened onto cable ladder KS80 with


connection piece SSR, and onto cable ladder KS20 with
connection piece SSR/KS20.

27.

BEND, T and X PIECES

X Piece KSX R=300

KS20, KS80

A
R = 300

Product

SSTL
number

Package Weight kg A mm
pc
/100 pcs

L mm

Hot dip galvanised after manufacture


KSX-150 R=300
KSX-200 R=300
KSX-300 R=300
KSX-400 R=300
KSX-500 R=300
KSX-600 R=300

14 495 76
14 495 77
14 495 78
14 495 79
14 495 80
14 495 81

1
1
1
1
1
1

530
626
660
700
780
833

150
200
300
400
500
600

1050
1100
1200
1300
1400
1500

530
626
660
700
780
833

150
200
300
400
500
600

1050
1100
1200
1300
1400
1500

Hot dip galvanised and painted after manufacture


PEX KSX-150 R=300
PEX KSX-200 R=300
PEX KSX-300 R=300
PEX KSX-400 R=300
PEX KSX-500 R=300
PEX KSX-600 R=300

14 307 21
14 307 22
14 307 23
14 307 24
14 307 25
14 307 26

1
1
1
1
1
1

X pieces can also be produced with radius R = 600

Installation examples
Fastening X piece to cable ladder

Fastening X piece to cable ladder


KSX

SSU

SSR

KSX

SSU
KS80

X piece KSX is fastened onto cable ladder KS80 with connection


piece SSU.

SSR
KS80

X piece KSX is fastened onto cable ladder KS80 with


connection piece SSR, and onto cable ladder KS20 with
connection piece SSR/KS20.

28.

BEND, T and X PIECES

Vertical angle KSV

KS20, KS80

430

430

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

A mm

Hot dip galvanised after manufacture


KSV-150
KSV-200
KSV-300
KSV-400
KSV-500
KSV-600

14 494 51
14 494 52
14 494 53
14 494 54
14 494 55
14 494 56

1
1
1
1
1
1

190
200
220
240
260
280

150
200
300
400
500
600

190
200
220
240
260
280

150
200
300
400
500
600

Hot dip galvanised and painted after manufacture


PEX KSV-150
PEX KSV-200
PEX KSV-300
PEX KSV-400
PEX KSV-500
PEX KSV-600

14 307 41
14 307 42
14 307 43
14 307 44
14 307 45
14 307 46

1
1
1
1
1
1

Installation example
Installation of vertical angle

SSR or SSU

KS80 or KS20

KSV

KS80 or KS20

Vertical angle KSV is fastened onto cable ladder KS20 with


extension piece SSR/KS20, and onto cable ladder KS80
with extension piece SSR or SSU.

29.

SUPPORTS

Wall support bracket VK 2 kN

KS20, KS80, KSF80


50

50

12 x 18
12 x 18

VK-150...VK-400

21
20

VK-500...VK-600

21
20

7 x 25
7 x 25

D
C

A
C

Product

SSTL
number

Package Weight
A
pc
kg/100 pcs mm

B
mm

C
mm

D
mm

G
mm

Hot dip galvanised after manufacture


VK-150 2 KN
VK-200 2 KN
VK-300 2 KN
VK-400 2 KN
VK-500 2 KN
VK-600 2 KN

14 495 90
14 495 91
14 495 92
14 495 93
14 495 94
14 495 95

10
10
10
10
10
10

35
42
54
80
115
128

190
240
340
440
540
640

93
93
93
108
155
155

36
39
44
50
75
80

46
46
46
56
118
118

12x15
12x15
12x15
12x15
12x18
12x18

35
42
54
80
115
128

190
240
340
440
540
640

93
93
93
108
155
155

36
39
44
50
75
80

46
46
46
56
118
118

12x15
12x15
12x15
12x15
12x18
12x18

Hot dip galvanised and painted after manufacture


PEX VK-150 2 KN
PEX VK-200 2 KN
PEX VK-300 2 KN
PEX VK-400 2 KN
PEX VK-500 2 KN
PEX VK-600 2 KN

14 307 61
14 307 62
14 307 63
14 307 64
14 307 65
14 307 66

10
10
10
10
10
10

Installation examples
Allowable load
F/2

Wall support
F/2

KS20
KK/KS20
VK

Allowable load F = 2 kN = 200 kg.

Wall support bracket VK can be fastened directly onto a wall


with a wedge anchor. Cable ladder KS20 is fastened onto wall
support bracket VK with brackets KK/KS20, and cable ladder
KS80 with brackets KK.

30.

SUPPORTS
Installation examples
Wall support

Wall support with anchor rail

AS
KK/KS20

KSF-VT
KKF

KSF80

KS20
VK

VK

Wall support bracket VK can be fastened directly onto a


wall with a wedge anchor. Cable ladder KSF80 is fastened
onto wall support bracket VK with brackets KKF.

Anchor rail AS can be used to disperse the load from wall


support bracket VK to a larger area. Wall support bracket
VK is fastened to anchor rail AS with sliding nuts SMT, TB or
with anchor rail nuts AKM.

Ceiling support

Ceiling support

TP2
SMT, TB or AKM
VK

HK2
SMT, TB or AKM
VK

Wall support bracket VK is fastened onto suspension bracket


HK2 with sliding nuts SMT, TB or with anchor rail nuts AKM.

Wall support bracket VK is fastened onto ceiling support


bracket TP2 with sliding nuts SMT, TB or with rail nuts AKM.

31.

SUPPORTS

Wall support bracket VKF 4 kN

KS20, KS80, KSF80

50

50

12 x 18, 2 pcs

VKF-200...600

G
E

12 x 25, 3 pcs

VKF-700...1000

7 x 25

7 x 25

A
C

A
C

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

A
mm

B
mm

C
mm

D
mm

E
mm

G
mm

70
90
124
167
199
288
342
413
500

240
340
440
540
640
740
840
940
1040

136
136
155
155
155
185
205
215
225

57
63
69
75
80
130
150
160
170

102
102
118
118
118
50
50
50
50

20
20
21
21
21
24
24
24
24

21
21
20
20
20
25
25
25
25

70
90
124
167
199
288
342
413
500

240
340
440
540
640
740
840
940
1040

136
136
155
155
155
185
205
215
225

57
63
69
75
80
130
150
160
170

102
102
118
118
118
50
50
50
50

20
20
21
21
21
24
24
24
24

21
21
20
20
20
25
25
25
25

Hot dip galvanised after manufacture


VKF-200 4 KN
VKF-300 4 KN
VKF-400 4 KN
VKF-500 4 KN
VKF-600 4 KN
VKF-700 4 KN
VKF-800 4 KN
VKF-900 4 KN
VKF-1000 4 KN

14 496 22
14 496 23
14 496 24
14 496 25
14 496 26
14 496 27
14 496 28
14 496 29
14 496 30

10
10
10
10
10
1
1
1
1

Hot dip galvanised and painted after manufacture


PEX VKF-200 4 KN
PEX VKF-300 4 KN
PEX VKF-400 4 KN
PEX VKF-500 4 KN
PEX VKF-600 4 KN
PEX VKF-700 4 KN
PEX VKF-800 4 KN
PEX VKF-900 4 KN
PEX VFK-1000 4 KN

14 307 72
14 307 73
14 307 74
14 307 75
14 307 76
14 307 77
14 307 78
14 307 79
14 307 80

10
10
10
10
10
1
1
1
1

Installation examples
Allowable load
F/2

Wall support
F/2

KK

KS80

VKF

Allowable load F = 4 kN = 400 kg.

Wall support bracket VKF can be fastened directly onto a wall


with a wedge anchor. Cable ladder KS20 is fastened onto wall
support bracket VKF with brackets KK/KS20, and cable ladder
KS80 with brackets KK.

32.

SUPPORTS
Installation examples
Wall support

Wall support with anchor rail


AS

KSF80

KKF
SMT or AKM
KK/KS20

KKF

KSF-VT

VKF
VKF

Wall support bracket VKF can be fastened directly onto a


wall with a wedge anchor. Cable ladder KSF80 is fastened
onto wall support bracket VKF with brackets KKF.

Anchor rail AS can be used to disperse the load from wall


support bracket VKF to a larger area. Wall support bracket
VKF is fastened to anchor rail AS with sliding nuts SMT, TB
or with anchor rail nuts AKM.

Ceiling support

Ceiling support
KS20

TP2
KK/KS20
HK2

SMT, TB or AKM

KS80

VKF
SMT, TB or AKM
KSF80
KKF
VKF

Wall support bracket VKF is fastened onto suspension


bracket HK2 with sliding nuts SMT, or with anchor rail
nuts AKM.

Wall support bracket VKF is fastened onto ceiling support


bracket TP2 with sliding nuts SMT, TB or with anchor rail
nuts AKM.

33.

SUPPORTS

Intermediate support bracket HK13


KS20, KS80, KSF80

7, 2 pcs.
B

50

33
A
C, 2 pcs.
9

Product

SSTL Package
number
pc

Weight kg
/100 pcs.

A mm

B mm

C mm

Ultimate
load, kg

Hot galvanised sheet metal


HK13-210/KS20
HK13-310/KS20
HK13-410/KS20
HK13-510/KS20
HK13-610/KS20

14 494 72
14 494 73
14 494 74
14 494 75
14 494 76

20
20
20
20
20

30
46
62
100
117

230
330
430
530
630

102
202
302
402
502

10.5
10.5
10.5
10.5
10.5

250
400
400
250
300

HK13-216/KS20
HK13-316/KS20
HK13-416/KS20
HK13-516/KS20
HK13-616/KS20

14 494 62
14 494 63
14 494 64
14 494 65
14 494 66

20
20
20
20
20

30
46
62
100
117

230
330
430
530
630

102
202
302
402
502

16.5
16.5
16.5
16.5
16.5

250
400
400
250
300

Hot dip galvanised after manufacture


HK13-150
HK13-210
HK13-310
HK13-410
HK13-510
HK13-610

14 496 41
14 496 42
14 496 43
14 496 44
14 496 45
14 496 46

20
20
20
20
20
20

18
33
51
69
110
129

180
230
330
430
530
630

52
102
202
302
402
502

10.5
10.5
10.5
10.5
10.5
10.5

250
250
400
400
250
300

HK13-216
HK13-316
HK13-416
HK13-516
HK13-616

14 496 92
14 496 93
14 496 94
14 496 95
14 496 96

20
20
20
20
20

33
51
69
110
129

230
330
430
530
630

102
202
302
402
502

16.5
16.5
16.5
16.5
16.5

250
400
400
250
300

Hot dip galvanised and painted after manufacture


PEX HK13-150
PEX HK13-210
PEX HK13-310
PEX HK13-410
PEX HK13-510
PEX HK13-610

14 308 41
14 308 42
14 308 43
14 308 44
14 308 45
14 308 46

20
20
20
20
20
20

18
33
51
69
110
129

180
230
330
430
530
630

52
102
202
302
402
502

10.5
10.5
10.5
10.5
10.5
10.5

250
250
400
400
250
300

PEX HK13-216
PEX HK13-316
PEX HK13-416
PEX HK13-516
PEX HK13-616

14 308 52
14 308 53
14 308 54
14 308 55
14 308 56

20
20
20
20
20

33
51
69
110
129

230
330
430
530
630

102
202
302
402
502

16.5
16.5
16.5
16.5
16.5

250
400
400
250
300

34.

SUPPORTS
Installation examples
Intermediate support with ceiling support bracket TP1

Intermediate support with


threaded rod

RTF-10

TP1

GT-10

RS 3

HK13
HK13

Intermediate support bracket HK13 is supported with threaded


rod GT.

Intermediate support bracket HK13 is supported with ceiling


support bracket TP1. Intermediate support bracket HK13 is
fastened onto ceiling support bracket TP1 with bolt set RS 3.

Intermediate support with threaded rod

Intermediate support with threaded rod

RTF-10/KS20
RTF-10
KS80

GT-10

GT-10

KK/KS20

KK

KS20
HK13

HK13/KS20

Intermediate support bracket HK13 is supported with threaded


rod GT. Cable ladder KS20 is fastened onto intermediate
support bracket HK13/KS20 with brackets KK/KS20.

Intermediate support bracket HK13 is supported with threaded


rod GT. Cable ladder KS80 is fastened onto intermediate
support bracket HK13 with brackets KK.

Intermediate support with ceiling support bracket TP1

Intermediate support with ceiling support bracket TP1

TP1

TP1
KS80

KSF80

KK

KK

HK13
RS 3

Intermediate support bracket HK13 is supported with ceiling


support bracket TP1. Intermediate support bracket HK13 is
fastened onto ceiling support bracket TP1 with bolt set RS 3.
Cable ladder KS80 is fastened onto intermediate support
bracket HK13 with bracket sKK.

HK13
RS 3

Intermediate support bracket HK13 is supported with ceiling


support bracket TP1. Intermediate support bracket HK13 is
fastened onto ceiling support bracket TP1 with bolt set RS 3.
Cable ladder KSF80 is fastened onto intermediate support
bracket HK13 with brackets KK.

35.

SUPPORTS

Bracket MK/KS20

KS20

10.5 x 10.5

26

Product

SSTL
number

Package
pc

10.5 x 10.5

26

Weight kg A mm
/100 pcs

B mm

Hot galvanised sheet metal


MK-210/KS20
MK-310/KS20
MK-410/KS20
MK-510/KS20
MK-610/KS20

14 494 31
14 494 32
14 494 33
14 494 34
14 494 35

10
10
10
10
10

30
47
64
81
98

180
280
380
480
580

10.5 x 12
10.5 x 12
10.5 x 12
10.5 x 12
10.5 x 12

MK-216/KS20
MK-316/KS20
MK-416/KS20
MK-516/KS20
MK-616/KS20

14 494 57
14 494 58
14 494 59
14 494 60
14 494 61

10
10
10
10
10

30
47
64
81
98

180
280
380
480
580

16
16
16
16
16

Hot galvanised and painted sheet metal


PEX MK-210/KS20
PEX MK-310/KS20
PEX MK-410/KS20
PEX MK-510/KS20
PEX MK-610/KS20

14 309 42
14 309 43
14 309 44
14 309 45
14 309 46

10
10
10
10
10

30
47
64
81
98

180
280
380
480
580

10.5 x 12
10.5 x 12
10.5 x 12
10.5 x 12
10.5 x 12

PEX MK-216/KS20
PEX MK-316/KS20
PEX MK-416/KS20
PEX MK-516/KS20
PEX MK-616/KS20

14 309 52
14 309 53
14 309 54
14 309 55
14 309 56

10
10
10
10
10

30
47
64
81
98

180
280
380
480
580

16
16
16
16
16

Installation examples
Intermediate
supporting for
KS20 cable ladder

RTF-10/KS20

Gate supporting
for KS20 cable
ladder

GT

RTF-10/KS20

GT

MK/KS20

MK/KS20

KS20

Intermediate bracket MK is used to


support cable ladder KS20.

MK/KS20

KS20

KS20

Intermediate support bracket MK can


be used in a gate support for cable
ladder KS20 together with threaded
rod GT-10.

36.

SUPPORTS

Inside wall support bracket VKI/KS20

KS20

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

A mm

10
10
10
10
10

92
120
148
176
203

180
280
380
480
580

10
10
10
10
10

92
120
148
176
203

180
280
380
480
580

Hot galvanised sheet metal


VKI-200/KS20
VKI-300/KS20
VKI-400/KS20
VKI-500/KS20
VKI-600/KS20

14 494 36
14 494 37
14 494 38
14 494 39
14 494 40

Hot galvanised and painted sheet metal


PEX VKI-200/KS20
PEX VKI-300/KS20
PEX VKI-400/KS20
PEX VKI-500/KS20
PEX VKI-600/KS20

14 308 82
14 308 83
14 308 84
14 308 85
14 308 86

Installation examples
Inside wall support

VKI/KS20

VKI/KS20

VKI/KS20
KS20

KS20
KS20
0 35 mm

Inside wall support bracket VKI/KS20 is


used to support cable ladder KS20.

37.

SUPPORTS

Ceiling support bracket TP1

KS20, KS80, KSF80


150
100

70
28
20
48
12 x 25, 2 pcs

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

L mm

10
10
10
10
1
1

60
90
125
156
224
287

270
495
765
990
1485
1980

60
90
125
156
224
287

270
495
765
990
1485
1980

Hot dip galvanised after manufacture


TP1-250
TP1-500
TP1-750
TP1-1000
TP1-1500
TP1-2000

14 496 01
14 496 02
14 496 03
14 496 04
14 496 06
14 496 08

Hot dip galvanised and painted after manufacture


PEX TP1-250
PEX TP1-500
PEX TP1-750
PEX TP1-1000
PEX TP1-1500
PEX TP1-2000

14 307 90
14 307 91
14 307 92
14 307 93
14 307 94
14 307 95

10
10
10
10
1
1

Installation examples
Allowable load

Intermediate support with ceiling support bracket TP1

TP1

HK13

Bolt set RS 3
F

With a symmetrical load the allowable load F of ceiling


support bracket TP1 is 3.5 kN = 350 kg.

Intermediate support bracket HK13 is supported with ceiling


support bracket TP1. Intermediate support bracket HK13 is
fastened onto ceiling support bracket TP1 with bolt set RS 3.

38.

SUPPORTS
Installation examples
Intermediate support with ceiling support bracket TP1

Intermediate support with ceiling support bracket TP1


KSF80

TP1
KS80
TP1
KK
KK

HK13

HK13
RS 3

RS 3

Intermediate support bracket HK13 is supported with ceiling


support bracket TP1. Intermediate support bracket HK13 is
fastened onto ceiling support bracket TP1 with bolt set RS 3.
Cable ladder KS80 is fastened onto intermediate support bracket
HK13 with brackets KK.

Intermediate support bracket HK13 is supported with ceiling


support bracket TP1. Intermediate support bracket HK13 is
fastened onto ceiling support bracket TP1 with bolt set RS 3.
Cable ladder KSF80 is fastened onto intermediate support
bracket HK13 with brackets KK.
Extension of ceiling
support bracket TP1

Gate support

TP1
TP1
JK

KK

FP-2000
TPK
KS80

RS 2

Industrial gate support TPK is fastened onto ceiling support


bracket TP1 with bolt sets RS 2.

Ceiling support bracket TP1 is extended to the desired length


using extension rail FP-2000 and extension piece JK.

Extension of ceiling support bracket TP1

TP1

RS 2
FP-2000

Ceiling support bracket TP1 is extended to the desired length


using extension rail FP-2000 and fastened with bolt sets RS 2.

39.

SUPPORTS

Ceiling support bracket TP2

KS20, KS80, KSF80

149
50

50

12 x 25, 8 pcs

50
53

149
22

50

48

Product

SSTL
number

Package Weight kg L mm
pc
/100 pcs

Hot dip galvanised after manufacture


TP2-500
TP2-1000
TP2-1500
TP2-2000
TP2-3000

14 496 10
14 496 13
14 496 15
14 496 17
14 496 18

10
1
1
1
1

215
395
663
863
1236

495
990
1485
1980
3015

215
395
663
863
1236

495
990
1485
1980
3015

Hot dip galvanised and painted after manufacture


PEX TP2-500
PEX TP2-1000
PEX TP2-1500
PEX TP2-2000
PEX TP2-3000

14 308 00
14 308 01
14 308 02
14 308 03
14 308 04

10
1
1
1
1

Installation examples
Allowable load

Allowable load

70

5m

H=3.0 m

L2

F1

H=2.0 m

H=1.5 m

50

F2

Lateral displacement f, mm

L1

VK or VKF

H=2.

60

40

30
H=1.0 m
20

TP2
10

0
0

With a symmetrical load the


allowable load F of ceiling support
bracket TP2 is 50 kN = 5000 kg.

0.2

0.4

0.6
0.8
Momentum, kNm

1.0

1.2

With an asymmetrical load M = F x L. Allowed maximum momentum with an asymmetrical


load is 1.1 kNm. In the case of an asymmetrical load, calculate the momentum caused by
the wall support bracket M = F x L, and look up the lateral displacement f of the ceiling
support bracket from the graph in point H.

40.

SUPPORTS
Installation examples
Ceiling support

Ceiling support

TP2

TP2
SMT

SMT

VK

VKF

Wall support bracket VK is fastened onto ceiling support


bracket TP2 with sliding nuts SMT, or with anchor rail nuts
AKM. Ceiling support bracket TP2 is fastened onto the ceiling
using, for example, wedge anchors.

Wall support bracket VKF is fastened onto ceiling support


bracket TP2 with sliding nuts SMT, or with anchor rail nuts
AKM. Ceiling support bracket TP2 is fastened onto the
ceiling using, for example, wedge anchors.

Ceiling support

Floor installation
SMT

KS20
TP2
KK/KS20
SMT
KS80

KK

VK

KSF80
TP2

KK
VKF

Ceiling support bracket TP2 can be used with cable


ladders KS20, KS80, and KSF80.

Ceiling support bracket TP2 is also suitable for floor


installations.

Support from l-beam

Extension of ceiling support bracket TP2


TP2
PL
RS 3
TP2
KK

JK
KS80
VKF

ASR

SMT

Ceiling support bracket TP2 is fastened onto an l-beam


using welded beam plate PL.

Ceiling support bracket TP2 can be extended with anchor


rail ASR and extension pieces JK (2 units). Bolt sets RS 3
are used.

41.

SUPPORTS

Ceiling support bracket TP2-L

KS20, KS80, KSF80

149
50

50

50

45
L

149

48

22

9 x 25

50

89
12 x 25, 8 pcs

Product

SSTL
number

Package Weight kg L mm
pc
/100 pcs

Hot dip galvanised after manufacture


TP2-L-500
TP2-L-1000
TP2-L-1500
TP2-L-2000
TP2-L-3000

14 491 30
14 491 31
14 491 32
14 491 33
14 491 34

10
1
1
1
1

340
550
760
970
1400

495
990
1485
1980
3015

340
550
760
970
1400

495
990
1485
1980
3015

Hot dip galvanised and painted after manufacture


PEX TP2-L-500
PEX TP2-L-1000
PEX TP2-L-1500
PEX TP2-L-2000
PEX TP2-L-3000

14 308 10
14 308 11
14 308 12
14 308 13
14 308 14

10
1
1
1
1

Installation examples
Allowable load

L1
F1

L2
F2

H=2,0 m

H=

2,5

H=3,0 m
60

70

Lateral displacement f, mm

Allowable load

50

H=1,5 m

40

30
H=1,0 m

20

10

0
0

0,2

0,4

0,6

0,8

1,0

1,2

1,4

1,6

1,8

2,0

Momentum, kNm

With a symmetrical load the allowable load F of ceiling support


bracket TP2-L is 80 kN = 8000
kg.

With an asymmetrical load M = F x L. Allowed maximum momentum with an asymmetrical


load is 2.3 kNm. In the case of an asymmetrical load, calculate the momentum caused by the
wall support bracket M = F x L, and look up the lateral displacement f of the ceiling support
bracket from the graph in point H.

42.

SUPPORTS
Installation examples
Ceiling support

Ceiling support

TP2-L
KS20
SMT

VKF
KS80

KSF80
VKF
TP2-L

Wall support bracket VKF is fastened onto ceiling support


bracket TP2-L with sliding nuts SMT, TB or with anchor rail
nuts AKM. Ceiling support bracket TP2-L is fastened onto
the ceiling using for example wedge anchors.

Ceiling support bracket TP2-L can be used with cable ladders


KS20, KS80, and KSF80.

Floor installation

Extension of ceiling support bracket TP2-L

SMT

TP2-L

RS 2
TP2-L
JK
VKF

ASR-L

Ceiling support bracket TP2-L is also suitable for floor


installations.

Ceiling support bracket TP2-L can be extended with anchor


rail ASR-L and extension pieces JK (2 units). Bolt sets RS2
are used (8 pcs).

43.

SUPPORTS

Ceiling support bracket TP2-P

KS20, KS80, KSF80

220
35,5

50

50

35,5

50

45
149

22

9 x 25

48

50

104

Product

SSTL
number

Package
pc

12 x 25, 12 pcs

Weight kg L mm
/100 pcs

Hot dip galvanised after manufacture


TP2-P-500
TP2-P-1000
TP2-P-1500
TP2-P-2000
TP2-P-3000

14 491 40
14 491 41
14 491 42
14 491 43
14 491 44

1
1
1
1
1

540
900
1260
1630
2350

495
990
1485
1980
3015

540
900
1260
1630
2350

495
990
1485
1980
3015

Hot dip galvanised and painted after manufacture


PEX TP2-P-500
PEX TP2-P-1000
PEX TP2-P-1500
PEX TP2-P-2000
PEX TP2-P-3000

14 308 20
14 308 21
14 308 22
14 308 23
14 308 24

1
1
1
1
1

Installation examples
Allowable load

Allowable load

70

Lateral displacement f, mm

H=3.0 m

L1
F1

L2

H=2.5 m

60

50
H=2.0 m
40

30
H=1.5 m

F2

20
H=1,0 m
f

10

0
0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

Momentum, kNm

With a symmetrical load the allowable


load F of ceiling support bracket TP2P is 80 kN = 8000 kg.

With an asymmetrical load M = F x L. Allowed maximum momentum with an


asymmetrical load is 3.7 kNm. In the case of an asymmetrical load, calculate the
momentum caused by the wall support bracket M = F x L, and look up the lateral
displacement f of the ceiling support bracket from the graph in point H.

44.

SUPPORTS
Installation examples
Ceiling support

Ceiling support

TP2-P

KS20

VKF
KS80

SMT, TB or AKM

KSF80
VKF
TP2-P

Wall support bracket VKF is fastened onto ceiling support


bracket TP2-P with sliding nuts SMT, TB or with anchor rail
nuts AKM. Ceiling support bracket TP2-P is fastened onto
the ceiling using, for example, wedge anchors.

Ceiling support bracket TP2-P can be used with cable ladders


KS20, KS80, and KSF80.

Floor installation

Extension of ceiling support bracket TP2-P

SMT, TB or AKM

TP2-P

TP2-P
VKF

JK

ASR-P

Ceiling support bracket TP2-P is also suitable for floor


installations.

Ceiling support bracket TP2-P can be extended with anchor


rail ASR-P and extension pieces JK (2 units). Hexagonal bolts
M8x120 and nut M8 are used (4 pcs).

45.

SUPPORTS

Suspension bracket HK2

KS20, KS80, KSF80

26
12 x 25, 2 pcs

22

48

180
250
45

9 x 25

Product

SSTL
number

Package
pc

Weight kg L mm
/100 pcs

Hot dip galvanised after manufacture


HK2-300
HK2-500
HK2-750
HK2-1000

14 496 33
14 496 35
14 496 37
14 496 40

10
10
10
10

115
144
192
240

315
495
765
990

115
144
192
240

315
495
765
990

Hot dip galvanised and painted after manufacture


PEX HK2-300
PEX HK2-500
PEX HK2-750
PEX HK2-1000

14 308 30
14 308 31
14 308 32
14 308 33

10
10
10
10

Installation examples
Allowed load

Ceiling support

70
HK2-1000

L
F

Lateral displacement f, mm

60

50
HK2-750

HK2

40

SMT, TB or AKM
VKF

30
HK2-500
20
HK2-300
10

f
0
0

0,1

0,2

0,3
0,4
0,5
Momentum, kNm

0,6

0,7

The graph above shows the allowed deflection-momentums Msall. for HK2 brackets.
Calculate the momentum caused by the wall support bracket M = F x L, and
look up the lateral displacement f of the suspension bracket from the graph. If
less lateral displacement is required, see the next page for use and load of lateral
support ST.

Ceiling support bracket VK or VKF are


fastened with sliding nuts SMT, TB or
anchor rail nuts AKM.

46.

SUPPORTS

Ceiling support HK1

KS20, KS80, KSF80

150
100

45

70

L
26

12 x 25 2 kpl

9 x 45

22
48

Product

SSTL
number

Package Weight kg L mm
pc
/100 pcs

Hot dip galvanised after manufacture


HK1-300
HK1-500
HK1-750
HK1-1000

14 494 97
14 494 98
14 494 99
14 495 00

10
10
10
10

86
121
172
216

325
505
775
1000

86
121
172
216

325
505
775
1000

Hot dip galvanised and painted after manufacture


PEX HK1-300
PEX HK1-500
PEX HK1-750
PEX HK1-1000

14 308 74
14 308 75
14 308 76
14 308 77

10
10
10
10

Installation examples
Ceiling support

Ceiling support
HK1
HK1

SMT, TB or AKM
VKI

SMT, TB or AKM
VK

KK-MK/KS20
KS20

Wall support brackets VK, VKF or VKI are fastened onto suspension bracket HK1 with sliding nuts SMT, with
anchor rail nuts AKM or with T-nuts TB.

47.

SUPPORTS

Lateral support ST

KS20, KS80, KSF80

12.5, 2 pcs

Product

SSTL
number

Package
pc

Weight kg A mm
/100 pcs

B mm

Hot dip galvanised after manufacture


ST-300
ST-500
ST-800
ST-1500

14 491 50
14 491 51
14 491 52
14 491 53

10
10
10
10

76
109
162
295

320
520
820
1520

221
221
221
365

76
109
162
295

320
520
820
1520

221
221
221
365

Hot dip galvanised and painted after manufacture


PEX ST-300
PEX ST-500
PEX ST-800
PEX ST-1500

14 308 70
14 308 71
14 308 72
14 308 73

10
10
10
10

Installation examples
Allowed load

Use of
lateral
support

20

Lateral displacement f, mm

ST300 and HK2-1000


ST500 and HK2-1000

15
ST300 and HK2-750

10

ST

HK2
ST500 and HK2-750

L
F

ST800 and
HK2-1000

SMT

VKF

ST300 and HK2-500

0,1

0,2

0,3

0,4

0,5

Momentum, kNm

The graph above shows the allowed deflection-momentums Msall. for HK2 brackets
and lateral support ST. Calculate the momentum caused by the wall support bracket
M = F x L, and look up the lateral displacement f of the suspension bracket from the
graph.

The deflection of suspension


bracket HK2 can be reduced by
installing lateral support ST.

48.

SUPPORTS

Gate support PRT/KS20

KS20

A
B

16.5
7, 2 pcs
11, 2 pcs

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

A mm

B mm

20
20
20
20
20

18
30
32
46
47

250
350
450
550
650

220
320
420
520
620

20
20
20
20
20

18
30
32
46
47

250
350
450
550
650

220
320
420
520
620

Hot galvanised sheet metal


PRT-200/KS20
PRT-300/KS20
PRT-400/KS20
PRT-500/KS20
PRT-600/KS20

14 499 70
14 499 71
14 499 72
14 499 73
14 499 74

Hot galvanised and painted sheet metal


PEX PRT-200/KS20
PEX PRT-300/KS20
PEX PRT-400/KS20
PEX PRT-500/KS20
PEX PRT-600/KS20

14 311 32
14 311 33
14 311 34
14 311 35
14 311 36

Installation example
Gate support
RTF-10/KS20

GT-10
KK/KS20

KS20
PRT/KS20

A gate support is built using threaded rods GT10 and gate support PRT/KS20.
Cable ladder KS20 is fastened onto gate support PRT/KS20 with brackets
KK/KS20.

49.

SUPPORTS

Industrial gate support TPK

KS80, KSF80

7, 2 pcs
11 x 25, 2 pcs

B
A

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

A mm

B mm

10
10
10
10
10

53
68
84
101
114

340
440
540
640
740

270
370
470
570
670

53
68
84
101
114

340
440
540
640
740

270
370
470
570
670

Hot dip galvanised after manufacture


TPK-200
TPK-300
TPK-400
TPK-500
TPK-600

14 494 92
14 494 93
14 494 94
14 494 95
14 494 96

Hot dip galvanised and painted after manufacture


PEX TPK-200
PEX TPK-300
PEX TPK-400
PEX TPK-500
PEX TPK-600

14 308 62
14 308 63
14 308 64
14 308 65
14 308 66

10
10
10
10
10

Installation examples
Gate support

Gate support

RS 2
F
AS

TP1

KS80

KK
TPK
RS 2
RS 2
KS80

TPK

Industrial gate support TPK is fastened onto ceiling support


bracket TP1 using bolt set 2. Cable ladder KS80 is fastened
onto industrial gate support TPK with brackets KK.

Industrial gate support TPK is fastened onto anchor rail AS


using bolt set 2. Anchor rail AS is fastened onto the ceiling
with end bracket F. Cable ladder KS80 is fastened onto
industrial gate support TPK with brackets KK.

50.

EXTENSION PIECES

Connection piece SSC/KS20

KS20

200

M6 x 12

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

Hot galvanised sheet metal


SSC/KS20

14 494 81

10

16

10

16

Hot galvanised and painted sheet metal


PEX SSC/KS20

14 311 40

Installation example

SSC/KS20
KS20

Connection pieces SSC/KS20 are used to extend cable ladder KS20.

51.

EXTENSION PIECES

Connection piece SSR

KS20, KS80

180

M6 x 12, 2 pcs

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

10

30

10

33

Hot galvanised sheet metal


SSR/KS20

14 494 82

Hot dip galvanised after manufacture


SSR

14 496 69

Hot dip galvanised and painted after manufacture


PEX SSR

14 308 90

10

33

Installation examples
Extending a cable ladder

Fastening an angle piece to a cable ladder

SSR/KS20
KS20

KS90
SSR

KS80

Connection pieces SSR/KS20 are used in extending cable


ladder KS20, and connection pieces SSR in extending
cable ladder KS80.

Bend KS90 is fastened onto cable ladder KS20 using


connection pieces SSR/KS20, and onto cable ladder
KS80 using connection pieces SSR.

52.

EXTENSION PIECES

Connection piece SSU

KS80

200

M8 + M8 x 80 lock bolt

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

10

63

Hot dip galvanised after manufacture


SSU

14 496 70

Hot dip galvanised and painted after manufacture


PEX SSU

14 308 91

10

63

Installation examples
Extending a cable ladder

Fastening a bend to a cable ladder


KS80

SSU

KS90

SSU
KS80
KS80

Connection pieces SSU are used in extending cable ladder


KS80.

Bend KS90 is fastened onto cable ladder KS80 using


connection pieces SSU.

53.

EXTENSION PIECES

Connection piece SSA/KSF80

KSF80

200

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

10

17

Hot dip galvanised after manufacture


SSA/KSF80

14 496 55

Hot dip galvanised and painted after manufacture


PEX SSA/KSF80

14 308 92

10

17

Installation example
Extending a cable ladder
SSA

KSF80

Cable ladder KSF80 is extended using connection pieces SSA and bolt sets KSF
from the end sections. Four bolt sets per extension are needed. If cable ladder
KSF80 is extended from some other point than the end sections products
KSF-NL can be used.

54.

EXTENSION PIECES

Angle joint NL

KS20, KS80

M6 x 12

65

M6 x 12
155 - 168.5

Product

SSTL
number

Package Weight kg
pc
/100 pcs

Hot galvanised sheet metal


NL/KS20

14 494 80

10

27

10

28

Hot dip galvanised after manufacture


NL

14 496 67

Hot dip galvanised and painted after manufacture


PEX NL

14 308 94

10

28

Installation examples
Change in vertical direction

T-branch

KS20
KS20

KS80 or KS20
NL/KS20
NL or NL/KS20

Using angle joints NL/KS20 the vertical direction of cable ladder


KS20, and angle joints NL the vertical direction of cable ladder
KS80 can be altered to any angle required.
Change in horizontal direction

A T-branch can be made by bending angle joints NL or NL/KS20


as shown.
Vertical branch
KS80
NL

NL

KS80

Horizontal direction of cable ladder KS20 or KS80 can be


altered by cutting the side tubes to different lengths and
using angle joints NL/KS20 or NL.

KS80

A vertical branch at any angle can be made using angle joints


NL/KS20 or NL.

55.

EXTENSION PIECES

Angle joint NL-TK

KS20, KS80, KSF80

67

207-227

Product

SSTL
number

Package
pc

Weight kg
/100 pc

10

72

Hot dip galvanised after manufacture


NL-TK

14 496 62

Hot dip galvanised and painted after manufacture


PEX NL-TK

14 308 95

10

72

Installation examples

NL-TK

KS80

NL-TK
KS80
NL-TK

Using angle joints NL-TK the vertical direction of cable ladder


KS80 can be altered to any angle required.
Joints NL-TK are reccommended to use in industrial
applications and harsh environments.

A T-branch can be made by bending angle joints NL-TK as shown.

56.

EXTENSION PIECES

Elbow joint KSF-NL

KSF80
150

100

12 x 25, 2 pcs

9, 2 pcs

Includes 2 M10 x 30 hexagonal bolts


and 2 nuts / product

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

10

34

Hot dip galvanised after manufacture


KSF NL

14 496 63

Hot dip galvanised and painted after manufacture


PEX KSF-NL

14 3091 8

10

34

Installation examples
Extending a cable ladder

Change in vertical direction

KSF80
KSF-NL

KSF80

KSF80

KSF-NL
KSF80

Elbow joints KSF-NL are used as cable ladder KSF80 is extended


from a point other than the end sections.

Using elbow joints KSF-NL the vertical direction of cable ladder


KSF80 can be altered to any angle required.

57.

EXTENSION PIECES

Extension piece JK

KS20, KS80, KSF80

9, 4 pcs

53

230

Includes 2 M8 x 40 hexagonal bolts


and 2 M8 nuts (bolt set 2) / product

Product

SSTL
number

Package Weight kg
pc
/100 pcs

Hot dip galvanised after manufacture


JK

14 496 73

10

26

Hot dip galvanised and painted after manufacture


PEX JK

14 308 93

10

26

Installation examples
Extending ceiling support bracket TP1

Extending ceiling support bracket TP2

TP1
TP2

JK

FP-2000

Bolt set RS 3

JK

ASR

Ceiling support bracket TP1 is extended to the desired length


using extension rail FP-2000 and extension piece JK.

Ceiling support bracket TP2 is extended using anchor rail


ASR and extension pieces JK (2 units), bolt sets 3 are used.

58.

INSTALLATION ACCESSORIES

Bracket KK-MK/KS20

KS20

M10x16 + M10
26

Includes M10 x 16 bolt


and M10 nut / product

Product

SSTL
number

Package Weight kg
pc
/100 pcs

Hot galvanised sheet metal


KK-MK/KS20

14 494 88

20

20

Hot galvanised and painted sheet metal


PEX KK-MK/KS20

14 311 47

Installation examples
RTF-10/KS20

RTF-10/KS20
GT-10

VKI/KS20

GT-10

KK-MK/KS20

KK-MK/KS20

MK/KS20
KS20

Cable ladder KS20 is fastened onto


support MK/KS20 with brackets
KK-MK/KS20.

MK/KS20
KS20

KK-MK/KS20
KS20

When gate support solution is used the


Cable ladder KS20 is fastened onto
support MK/KS20 and brackets KK-MK
support VKI/KS20 with brackets
are fastened with threaded rods and nuts. KK-MK/KS20.

59.

INSTALLATION ACCESSORIES

Bracket KK

KS20, KS80, KSF80

58

M6 + M6 x 12

Includes M6 x 12 hexagonal bolt


and M6 nut (bolt set 1) / product

Product

SSTL
number

Package Weight kg
pc
/100 pcs

Hot galvanised sheet metal


KK/KS20

14 494 86

20

20

Hot dip galvanised after manufacture


KK

14 496 76

Hot dip galvanised and painted after manufacture


PEX KK

14 309 00

20

Installation examples
Fastening to wall support bracket

Fastening to industrial gate support

Fastening to gate support

KS20
RTF-10/KS20

KK/KS20
TP1

GT-10
KK

KK/KS20

VK

TPK
KS80

Cable ladder KS20 is fastened onto wall


support bracket VK with brackets KK/KS20,
and cable ladder KS80 with brackets KK.

RS 2

Cable ladder KS80 is fastened onto


industrial gate support TPK with
brackets KK.

PRT/KS20
KS20

Cable ladder KS20 is fastened onto gate


support PRT with brackets KK/KS20.

60.

INSTALLATION ACCESSORIES

Bracket KKF

KSF80

M6 + M6 x 12

19

Includes M6 x 12 hexagonal bolt


and M6 nut (bolt set 1) / product

Product

SSTL
number

Package Weight kg
pc
/100 pcs

Hot dip galvanised after manufacture


KKF

14 496 78

20

Hot dip galvanised and painted after manufacture


PEX KKF

14 309 02

20

Installation example
Fastening to wall support bracket

KSF80
KKF
VKF

Cable ladder KSF80 is fastened onto wall support bracket VK or VKF with
brackets KKF.

60.

INSTALLATION ACCESSORIES

Wall brackets VK2 and VK3

KS20, KS80

95

M8 + M8 x 30 lock bolt
140
M8 + M8 x 30 lock bolt
75

31

11 x 25

11 x 25

VK2

VK3
Includes M8 x 30 lock bolt
and M8 nut

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

A mm

10

19

32

10
10

24
29

32
77

24
29

32
77

Hot galvanised sheet metal


VK2/KS20

14 494 79

Hot dip galvanised after manufacture


VK2
VK3

14 496 71
14 496 68

Hot dip galvanised and painted after manufacture


PEX VK2
PEX VK3

14 309 03
14 309 04

10
10

Installation examples
Fastening a vertical tray to a wall

Installing switch cabinets

Installing lighting

AS

KS80

KS80

VK2

KS80

VK2
VK2

A vertical tray is fastened onto a wall


with wall brackets VK2 or VK3. Wall
brackets are fastened onto the wall with,
for example, wedge anchors.

Switch cabinets can be fastened onto


cable ladder KS80 as shown.

Lighting elements can be fastened onto


cable ladder KS20 using wall brackets
VK2/KS20, and onto cable ladder KS80
using wall brackets VK2.

61.

INSTALLATION ACCESSORIES

End bracket F

KS20, KS80
55

12 x 25, 2 pcs

10

75
55
31

36
55

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

20

19

Hot dip galvanised after manufacture


F

14 496 79

Hot dip galvanised and painted after manufacture


PEX F

14 309 13

20

19

Installation examples
Fastening to a floor

Gate support

KS80

VK2
RS 2

AS
KS80

SK
SP
F
RS 2

Cable ladder KS20 or KS80 is fastened onto a floor using


end brackets F.

End brackets F can be used in a gate support as shown.

62.

INSTALLATION ACCESSORIES

T-branch bracket VF

KS20, KS80

65

59
M6 x 12

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

10

18

Hot dip galvanised after manufacture


VF

14 496 66

Hot dip galvanised and painted after manufacture


PEX VF

14 309 10

10

18

Installation examples
T-branch

Use of branch plates in a T-branch


KS80

VF

AG
KS80

VF
KS80

T-branch brackets VF are used when making a T-branch for


cable ladders KS20 or KS80.

The use of branch plates AG is always reccommended in


the T-branch.

63.

INSTALLATION ACCESSORIES

Straight angle bracket VFF/KSF80

KSF80

50

100

148

74

Includes M10 x 30
hexagonal bolts
and M10 nuts 2 / product

12 x 25, 2 pcs

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

10

42

Hot dip galvanised after manufacture


VFF/KSF80

14 496 80

Hot dip galvanised and painted after manufacture


PEX VFF/KSF80

14 309 11

10

42

Installation example
T-branch

VFF
KSF80

KSF80

Straight angle brackets VFF/KSF80 are used in making a T-branch in cable


ladders KSF80.

64.

INSTALLATION ACCESSORIES

Branch plate AG

KS20, KS80

254

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

Hot galvanised sheet metal


AG

14 496 90

10

37

10

37

Hot galvanised and painted sheet metal


PEX AG

14 309 23

Installation example
Use of branch plates in a T-branch
KS80

VF
AG
KS80

Use of branch plates AG is always recommended in a T-branch. Cable


ladders are fastened onto each other using T-branch brackets VF.

65.

INSTALLATION ACCESSORIES

Vertical tray bracket VEF 2

Product

SSTL
number

Package
pc

KS20, KS80

Weight kg
/100 pcs

Hot dip galvanised after manufacture


VEF 2

14 496 75

10

23

Hot dip galvanised and painted after manufacture


PEX VEF 2

14 309 22

10

23

Installation example
Vertical branch
KS80

KS80

VEF 2

Vertical tray brackets VEF 2 are used in making a vertical branch for cable
ladders KS20 or KS80.

66.

INSTALLATION ACCESSORIES

Narrowing bracket FM

KS20, KS80

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

L mm

10
10
10

65
87
110

100
200
300

65
87
110

100
200
300

Hot dip galvanised after manufacture


FM-100
FM-200
FM-300

14 496 57
14 496 58
14 496 59

Hot dip galvanised and painted after manufacture


PEX FM-100
PEX FM-200
PEX FM-300

14 309 24
14 309 25
14 309 26

10
10
10

Installation example
Narrowing

SSU

KS80

FM

KS80

Narrowing bracket FM is used in narrowing a cable ladder.

67.

INSTALLATION ACCESSORIES

Intermediate support KSF-VT

KSF80

M8 + M8 x 20

Includes M8 x 20 hexagonal bolts


and M8 nuts (2 pcs) / product

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

10

26

Hot dip galvanised after manufacture


KSF-VT

14 496 82

Hot dip galvanised and painted after manufacture


PEX KSF-VT

14 309 12

10

26

Installation example
Use of intermediate support

KSF80
KSF-VT
VKF

If cable ladder KSF80 has to be supported between the support plates


supports KSF-VT are used.

68.

INSTALLATION ACCESSORIES

Ceiling bracket RTF-10 and RTF-16


KS20, KS80, KSF80
12

60
50

80

11
70

17

RTF-10

25

11
40

Product

RTF-16

50

SSTL
number

Package
pc

Weight kg
/100 pcs

20

12

20
10

12
23

Hot galvanised sheet metal


RTF-10/KS20

14 494 84

Hot dip galvanised after manufacture


RTF-10
RTF-16

14 496 52
14 496 53

Hot dip galvanised and painted after manufacture


PEX RTF-10
PEX RTF-16

14 309 05
14 309 06

10
10

13
24

Installation examples
Threaded rod suspension

Gate support
RTF-10/KS20

RTF-10
GT-10

KS80

GT-10
KK

KK/KS20

HK13

KS20
PRT/KS20

Ceiling bracket RTF is used in threaded rod ceiling suspension.


The ceiling bracket is fastened onto the roof, for example,
with a wedge anchor. Cable ladder KS20 requires ceiling
bracket RTF/KS20 and cable ladder KS80 ceiling bracket RTF.

Ceiling brackets RTF are used for fastening a threaded rod


to the ceiling in a gate support. Cable ladder KS20 requires
ceiling brackets RTF/KS20 and cable ladder KS80 ceiling
brackets RTF.

69.

INSTALLATION ACCESSORIES

Adjustable ceiling bracket RTF-SKS20, KS80, KSF80


125

11 x 20, 3 pcs
100

9 x 40

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

10

29

Hot dip galvanised after manufacture


RTF-S

14 496 54

Hot dip galvanised and painted after manufacture


PEX RTF-S

14 309 19

10

29

Installation example
Fastening to a slanting ceiling
RTF-S

AS

Adjustable ceiling bracket RTF-S is used to fasten anchor rail AS or extension


rail FP-2000 onto a slanting ceiling. The angle of the ceiling can be 67
113. Adjustable ceiling bracket RTF-S is fastened onto anchor rail AS or
extension rail FP-2000 using bolt set 2.

70.

INSTALLATION ACCESSORIES

Ceiling bracket RTF-Z

KS20, KS80, KSF80

50
12

17

70

25

25

50

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

Hot dip galvanised after manufacture


RTF-Z

14 496 56

10

23

Hot dip galvanised and painted after manufacture


PEX RTF-Z

14 309 07

10

23

Installation example
Use of ceiling bracket

RTF-Z

46

GT

Ceiling bracket RTF-Z is used when fastening to the ceiling cannot be accomplished
in exactly the right spot and threaded rod GT is to be vertical. Ceiling bracket RTF-Z
has an adjusting reach of 92 mm.

71.

INSTALLATION ACCESSORIES

Ceiling support bracket ASR-TF

KS20, KS80, KSF80

149
50

50
12 x 25, 8 pcs

50

221

149

53
50

57

Includes 4 M8 x 70 hexagonal bolts


and 4 nuts M8 / product
Product

SSTL
number

Package
pc

Weight kg
/100 pcs

150

Hot dip galvanised after manufacture


ASR-TF

14 496 65

Hot dip galvanised and painted after manufacture


PEX ASR-TF

14 309 17

150

Installation example
Ceiling support

ASR-TF

ASR

Ceiling support bracket ASR-TF is used in ceiling and


floor installations together with anchor rail ASR.
Ceiling support bracket ASR-TF is fastened onto anchor
rail ASR using the bolts provided.

72.

INSTALLATION ACCESSORIES

Threaded rod GT

KS20, KS80, KSF80

Product

SSTL
number

Package
m

Weight kg
/100 m

Thread

14 496 50
14 496 51

50
20

50
130

M10
M16

2m
2m

50
20

50
130

M10
M16

2m
2m

Lenght

Zinc electroplated
GT-10
GT-16

Hot dip galvanised after manufacture


GT-10 ZNK
GT-16 ZNK

14 491 60
14 491 61

Installation examples
Intermediate support using threaded rod

Gate support using threaded rod

RTF-10

RTF-10/KS20

GT-10
GT-10
KS80
KK
KK/KS20

KS20
HK13
PRT/KS20

Threaded rod GT is used in an intermediate support


together with intermediate support bracket HK13 and
ceiling bracket RTF.

Threaded rods GT are used in a gate support together with


gate support bracket PRT/KS20 and ceiling brackets
RTF-10/KS20.

73.

INSTALLATION ACCESSORIES

Anchor rail AS

KS20, KS80, KSF80

48

22

45

9 x 25
26

Product

SSTL
number

Package
m

Weight kg
/100 m

Length
L

Hot dip galvanised after manufacture


AS

14 496 48

60

190

6m

190

6m

Hot dip galvanised and painted after manufacture


PEX AS

14 310 10

60

Installation examples
Wall support with anchor rail

Gate support
F
AS
RS 3

AS

KK

KS80
AS

SP

SMT
KS80
VKF

Anchor rail AS can be used to disperse the load from wall


support bracket VK or VKF to a larger area. Wall support
bracket VK or VKF is fastened onto anchor rail AS with sliding
nuts SMT, TB or anchor rail nuts AKM.

Anchor rail AS and the end bracket can be used to build a


gate support as shown.

Fastening to a slanting ceiling

Installing switch cabinets


AS

RTF-S
KS80

VK2
AS

Adjustable ceiling bracket RTF-S is used to fasten anchor rail


AS onto a slanting ceiling. Adjustable ceiling bracket RTF-S
is fastened onto anchor rail AS using bolt set 2.

Switch cabinets can be fastened with anchor rails AS and


wall brackets VK2 onto cable ladder KS80 as shown.

74.

INSTALLATION ACCESSORIES

Anchor rail ASR

KS20, KS80, KSF80

48

22

9 x 25

45

53

Product

SSTL
number

Package
m

Weight kg
/100 m

Length
L

60

380

6m

380

6m

Hot dip galvanised after manufacture


ASR

14 496 60

Hot dip galvanised and painted after manufacture


PEX ASR

14 310 11

60

Installation examples
Fastening wall
support bracket

Ceiling support
ASR
SMT, TB or AKM
ASR-TF

VK

ASR

Wall support bracket VK or VKF is fastened onto anchor rail


ASR using sliding nuts SMT, TB or anchor rail nuts AKM.

Ceiling support bracket ASR-TF is used in ceiling and floor


installations together with anchor rail ASR.

Support between ceiling and floor

Extension of ceiling support bracket TP2

RS 3
TP2

ASR
RS 3

F
ASR

Anchor rail ASR and four end brackets F are fastened with
bolt sets 3 to make a column between the floor and ceiling.

Ceiling support bracket TP2 is extended with anchor rail ASR


and extension pieces JK (2 units). Bolt sets 3 is used.

75.

INSTALLATION ACCESSORIES

Anchor rail ASR-L

KS20, KS80, KSF80

89

9 x 25

22

48

45

Product

SSTL
number

Package
m

Weight kg
/100 m

Lenght
L

60

420

6m

420

6m

Hot dip galvanised after manufacture


ASR-L

14 491 36

Hot dip galvanised and painted after manufacture


PEX ASR-L

14 310 12

60

Installation examples
Fastening wall support bracket

Support between ceiling and floor


SMT

RS 2

VKF
TP2-L
ASR-L

Wall support bracket VK or VKF is fastened onto anchor rail


ASR-L using sliding nuts SMT, TB or anchor rail nuts AKM.

Anchor rail ASR-L and four end brackets F are fastened with
bolt sets RS2 to make a column between the floor and ceiling.

Extension of ceiling support


bracket TP2-L
TP2-L

RS 2
JK

ASR-L

Ceiling support bracket TP2-L is extended with anchor rail


ASR-L and extension pieces JK (2 pcs). Bolt sets RS2 are used.

76.

INSTALLATION ACCESSORIES

Anchor rail ASR-P

KS20, KS80, KSF80

104

45
L
22

48

9 x 25

Product

SSTL
number

Package
m

Weight kg
/100 m

Lenght
L

60

845

6m

845

6m

Hot dip galvanised after manufacture


ASR-P

14 491 37

Hot dip galvanised and painted after manufacture


PEX ASR-P

14 310 13

60

Installation examples
Fastening wall support bracket

Support between ceiling and floor


ASR-P

VKF

ASR-P

SMT
F

Wall support bracket VK or VKF is fastened onto anchor rail


ASR-P using sliding nuts SMT, TB or anchor rail nuts AKM.

Anchor rail ASR-P and four end brackets F are fastened with
bolt sets RS3 to make a column between the floor and ceiling.

Extension of ceiling support bracket TP2-P


TP2-P

JK

ASR-P

Ceiling support bracket TP2-P is extended with anchor rail


ASR-P and extension pieces JK (2 units). Hexagonal bolts
M8x120 and nuts M8 are used (4 pcs).

77.

INSTALLATION ACCESSORIES

Extension rail FP-2000

KS20, KS80, KSF80

20
28
48

9 x 25
45

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

Length
L

10

250

2m

250

2m

Hot dip galvanised after manufacture


FP-2000

14 496 20

Hot dip galvanised and painted after manufacture


PEX FP-2000

14 310 14

10

Installation examples
Extension of ceiling support bracket TP1

Fastening to a slanting ceiling

RFT-S
TP1
RS 2
JK

FP-2000

Ceiling support bracket TP1 is extended to the desired length


using extension rail FP-2000 and extension piece JK.

AS

Adjustable ceiling bracket RTF-S is used to fasten extension


rail FP-2000 onto a slanting ceiling. Adjustable ceiling bracket
RTF-S is fastened onto extension rail FP-2000 using bolt
set RS2.

78.

INSTALLATION ACCESSORIES

Profile CK

KS20, KS80

25
11 x 15

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

Length
L

10

45

1m

10

45

1m

Hot galvanised sheet metal


CK

14 496 21

Hot galvanised and painted sheet metal


PEX CK

14 310 15

Installation example
Use of CK
C-rail
KK

Profile CK is fastened onto cable ladder KS80 with brackets


KK. The CK-profile is used, for example, when lighting elements
are fastened onto a cable ladder.

79.

INSTALLATION ACCESSORIES

Ceiling suspension bracket TFP

KS20, KS80

5, 4 pcs

75

11, 2 pcs
20

21

35

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

10

12

10

12

Hot galvanised sheet metal


TFP

14 496 64

Hot galvanised and painted sheet metal


PEX TFP

14 309 20

Installation example
Fastening onto a trapeze section
SMT

TFP

TP1

AS

Ceiling support bracket TP1 can be fastened onto a trapeze section with
anchor rail AS and ceiling suspension brackets TPF.

80.

INSTALLATION ACCESSORIES

Corrugated bar bracket HTK-AS KS20, KS80, KSF80


230

28
150

M10 x 20

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

10

64

Hot dip galvanised after manufacture


HTK-AS

14 497 06

Hot dip galvanised and painted after manufacture


PEX HTK-AS

14 309 28

10

64

Installation example
Use of corrugated bar bracket

CORRUGATED BAR

KK
HTK-AS

KS80

VK

Corrugated bar bracket HTK-AS is fastened onto a corrugated bar hanging


from the ceiling. Wall support bracket VK or VKF is fastened onto corrugated
bar bracket HTK-AS using sliding nuts SMT or anchor rail nuts AKM.

81.

INSTALLATION ACCESSORIES

Corrugated bar bracket HTK-LK KS20, KS80, KSF80


130

50
9,2 pcs

28

150
M10 x 20

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

Hot dip galvanised after manufacture


HTK-LK

14 497 07

10

50

Hot dip galvanised and painted after manufacture


PEX HTK-LK

14 309 29

10

50

Installation example
Using corrugated
bar bracket
AS

RS 2

HTK-LK

CORRUGATED BAR

Corrugated bar bracket HTK-LK is fastened onto a corrugated bar


hanging from the ceiling, or rising from the floor. Anchor rail AS
is fastened onto corrugated bar bracket HTK-LK using bolt sets RS2.

82.

INSTALLATION ACCESSORIES

Corrugated bar bracket HTK-SK KS20, KS80, KSF80


32

9
48

28

150

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

Hot dip galvanised after manufacture


HTK-SK

14 497 08

10

40

Hot dip galvanised and painted after manufacture


PEX HTK-SK

14 309 30

10

40

Installation example
Using corrugated
bar bracket

AS

HTK-SK
CORRUGATED BAR
RS 2

Corrugated bar bracket HTK-SK is fastened onto a corrugated bar


protruding from a wall. Anchor rail AS is fastened onto corrugated bar
bracket HTK-SK with bolt set 2.

83.

INSTALLATION ACCESSORIES

Beam plate PL

KS20, KS80, KSF80

149
149

12 x 25, 8 pcs

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

10

96

Hot dip galvanised after manufacture


PL

14 491 56

Hot dip galvanised and painted after manufacture


PEX PL

14 309 31

10

96

Installation example
Support from an l-beam

PL
TP2
KK
RS KSF

KS80

SMT

VKF

Ceiling support bracket TP2 is fastened, for instance, onto an l-beam using
beam plate PL. Beam plate PL is welded onto the l-beam, and ceiling support
bracket TP2 is fastened onto beam plate PL using bolt sets KSF.

84.

INSTALLATION ACCESSORIES

Beam bracket PK1

KS20, KS80, KSF80

11

20

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

Hot dip galvanised after manufacture


PK1

14 496 31

10

15

Installation example
l-beam

PK1

GT-10

KK

KS80
HK13

Ceiling support bracket HK13, for instance, is fastened onto an l-beam


using threaded rod GT-10 and beam bracket PK1.
Maximum traction load of beam bracket PK1 is 300 kg.

85.

INSTALLATION ACCESSORIES

Beam bracket PK2

KS20, KS80, KSF80

60

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

10

25

Hot dip galvanised after manufacture


PK2

14 496 32

Installation example
l-beam

PK2
PK2
AS
RS K
TP1
KK

RS3

HK13

Ceiling support bracket TP1, for instance, is fastened onto an l-beam using beam brackets PK2 (2 pcs.) and AS profile.
Support bracket TP1 is fastened onto profile AS using bolt sets RS K (SSTL nr. 14 317 35).
Brackets PK2 are suitable for I-beam with thickness max. 18 mm.

86.

INSTALLATION ACCESSORIES

Coupling plate DPA

KS20, KS80, KSF80

210

180

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

10

31

10

31

Hot galvanised sheet metal


DPA

14 496 85

Hot galvanised and painted sheet metal


PEX DPA

14 309 14

Installation example
Fastening boxes
DPA

KS80

DPA

Coupling plate DPA is used to fasten switch boxes, coupling boxes etc. onto
the side of a cable ladder. Coupling plate DPA is fastened onto a cable ladder
by bending the fastening sections around the side tube. If necessary, the
joint can be secured with sheet-iron screws.

87.

INSTALLATION ACCESSORIES

Coupling plate DPB-120

KS20, KS80, KSF80

250
125

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

Hot galvanised sheet metal


DPB-120

14 496 87

10

29

10

29

Hot galvanised and painted sheet metal


PEX DPB-120

14 309 15

Installation example
Fastening boxes

KS80

DPB-120

Coupling plate DPB-120 is used to fasten switch boxes, coupling boxes etc.
onto the rungs of cable ladders. Coupling plate DPB-120 is fastened onto
the rung by bending the fastening sections into the hole.

88.

INSTALLATION ACCESSORIES

Coupling plate KL

KS20, KS80, KSF80

15
15
510

30

Includes screws for fastening.

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

A mm

Hot dip galvanised sheet metal


KL-150
KL-200
KL-300
KL-400
KL-500
KL-600

14 492 01
14 492 02
14 492 03
14 492 04
14 492 05
14 492 06

10
10
10
10
10
10

150
180
240
300
360
420

151
201
301
401
501
601

Installation example

Coupling plate KL is used to fasten switch cabinets and boxes,


coupling boxes etc. equipment.

89.

INSTALLATION ACCESSORIES

Protective cap P

KS20, KS80

60

15

Product

SSTL
number

Package
pc

14 496 81

10

Weight kg
/100 pcs

Plastic, black
P

Installation example
Protects the end of a cable ladder

KS80

Protective caps P are used at the ends of cable ladders KS20 and KS80 to
prevent dust and dirt from entering inside of the ladder.

90.

INSTALLATION ACCESSORIES

Protective cap SP

KS20, KS80

48

26

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

Plastic, black
SP

14 496 72

10

Installation example
Protects the end of an anchor rail
F
RS 2
AS
KS80

AS
SP

Protective caps SP are used to protect the ends of anchor rail AS,
or extension rail FP.

91.

INSTALLATION ACCESSORIES

Cable clip KP

Product

SSTL
number

KS20, KS80, KSF80

Package
pc

Weight kg
/100 pcs

200
200
200
200
200
200
150
100
100
100
100

2
2
3
3
3
4
4
7
9
10
11

Hot galvanised sheet metal


KP12
KP14
KP18
KP22
KP26
KP30
KP34
KP40
KP46
KP52
KP60

13 240 62
13 240 64
13 240 68
13 240 70
13 240 72
13 240 74
13 240 76
13 240 78
13 240 80
13 240 82
13 240 84

Installation examples
Fastening cables

Fastening cables
KP

KS80

Cable clips KP are used to fasten cables onto the rungs of cable Cable clips KP are used to fasten cables onto
ladders KS20, KS80, and KSF80.
anchor rail AS.

92.

INSTALLATION ACCESSORIES

Zink spray

KS20, KS80, KSF80

Zn-spray

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

14 497 09

43

Zinc spray
MEKA ZN-SPRAY

Installation example
Use of zinc spray

Zinc spray is used to protect surfaces after they have been cut or damaged.

93.

COVERS

Protective cover SK

KS20, KS80, KSF80

50
30
1500
A

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

A mm

Hot galvanised sheet metal


SK-150
SK-200
SK-300
SK-400
SK-500
SK-600

14 497 11
14 497 12
14 497 13
14 497 14
14 497 15
14 497 16

10
10
10
10
10
10

378
468
648
828
1008
1188

151
201
301
401
501
601

10
10
10
10
10
10

378
468
648
828
1008
1188

151
201
301
401
501
601

Hot galvanised and painted sheet metal


PEX SK-150
PEX SK-200
PEX SK-300
PEX SK-400
PEX SK-500
PEX SK-600

14 309 61
14 309 62
14 309 63
14 309 64
14 309 65
14 309 66

Installation examples
Protection of cables

Protection of cables

VK2

SK

KS80
KAP
SK
F

Protective cover SK is used as a kick protection for cables,


and it is fastened onto a cable ladder with sheet-iron screws.

Cover clips KAP are used to obtain more cable space under
protective cover SK.

94.

COVERS

Cover clip KAP

KS20, KS80, KSF80


40

M8 + M8 x 40 lock bolt
114

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

Hot galvanised sheet metal


KAP

14 497 00

10

22

10

22

Hot galvanised and painted sheet metal


PEX KAP

14 309 27

Installation example
Protection of cables

KS80
KAP
SK

Cover clips KAP are used to obtain more cable space under
protective cover SK.

95.

COVERS

Dust protection cover PSK

KS20, KS80, KSF80

C
A

Product

SSTL
number

Package
m

Weight kg A mm
/100 m

B mm

C mm

Lenght
L mm

Hot galvanised sheet metal


PSK-150
PSK-200
PSK-300
PSK-400
PSK-500
PSK-600

14 491 00
14 491 01
14 491 02
14 491 03
14 491 04
14 491 05

30
30
30
30
30
30

220
248
314
386
462
539

151
201
301
401
501
601

50
50
70
70
70
70

30
30
30
30
30
30

3000
3000
3000
3000
3000
3000

30
30
30
30
30
30

220
248
314
386
462
539

151
201
301
401
501
601

50
50
70
70
70
70

30
30
30
30
30
30

3000
3000
3000
3000
3000
3000

50
50
50
50
50
50

55
55
55
55
55
55

1500
1500
1500
1500
1500
1500

Hot galvanised and painted sheet metal


PEX PSK-150
PEX PSK-200
PEX PSK-300
PEX PSK-400
PEX PSK-500
PEX PSK-600

14 309 91
14 309 92
14 309 93
14 309 94
14 309 95
14 309 96

Hot galvanised sheet metal with "Pural" surface treatment (gray RR22 RAL 7045)
PSK-150 PURAL
PSK-200 PURAL
PSK-300 PURAL
PSK-400 PURAL
PSK-500 PURAL
PSK-600 PURAL

14 310 91
14 310 92
14 310 93
14 310 94
14 310 95
14 310 96

15
15
15
15
15
15

160
180
230
280
330
385

151
201
301
401
501
601

Installation example
Use of dust protection cover

PSK

KS80

Dust protection cover PSK is used to prevent dirt and dust


from gathering on top of cables. Dust protection cover PSK
is fastened onto a cable ladder with sheet-iron screws.

96.

COVERS

Bottom plate POL

KS20, KS80, KSF80

3000

Product

SSTL
number

Package
m

Weight kg
/100 m

A mm

30
30
30
30
30

102
162
222
282
342

168
268
368
468
568

30
30
30
30
30

102
162
222
282
342

168
268
368
468
568

Hot galvanised sheet metal


POL-200
POL-300
POL-400
POL-500
POL-600

14 494 12
14 494 13
14 494 14
14 494 15
14 494 16

Hot galvanised and painted sheet metal


PEX POL-200
PEX POL-300
PEX POL-400
PEX POL-500
PEX POL-600

14 309 72
14 309 73
14 309 74
14 309 75
14 309 76

Installation example
Use of bottom plate
POL

KS80

Bottom plate POL is used together with a cable ladder for protection and as a screen.

97.

COVERS

Separation plate AP

KS20, KS80, KSF80

250
A

25
27.5
25

25

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

A mm

10
10

66
42

2746
1746

10
10

66
42

2746
1746

Hot galvanised sheet metal


AP L=2750
AP L=1750

14 497 10
14 497 18

Hot galvanised and painted sheet metal


PEX AP L=2750
PEX AP L=1750

14 310 01
14 310 00

Installation examples
Separating low current and power supply cables

Fastening to cable ladder rung

AP

AP
KS80
KS80

Separation plate AP is used to separate low current and power


supply cables from each other.

Separation plate AP is fastened onto a cable ladder rung using


cable ties.

98.

COVERS

Low current gutter SR

KS20, KS80, KSF80

Pre-cut opening 25
7
250
1996
25

Product

SSTL
number

Package
m

Weight kg
/100 pcs

A mm

20
20
20

40
60
77

50
100
150

20
20
20

40
60
77

50
100
150

Hot galvanised sheet metal


SR-50
SR-100
SR-150

14 497 01
14 497 02
14 497 03

Hot galvanised and painted sheet metal


PEX SR-50
PEX SR-100
PEX SR-150

14 310 02
14 310 03
14 310 04

Installation examples
Separating low current and power supply cables

Fastening to cable ladder rung

SR

KS80

SR

KS80

Low current gutter SR is used when a separate cable conduit


is required for low current cables.

Low current gutter SR is fastened onto a cable ladder rung


using cable ties.

99.

BOLT SETS

Sliding nut SMT

KS20, KS80, KSF80

M10 + M10 x 40 lock bolt

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

Hot dip galvanised after manufacture


SMT

14 496 84

20

Hot dip galvanised and painted after manufacture


PEX SMT

14 310 22

20

Installation examples
Allowed load

Fastening a wall support bracket to an anchor rail


TP2

SMT

VK

Maximum traction load F of sliding nut SMT is 800 kg.

A wall support bracket is fastened onto an anchor rail using


sliding nut SMT.

100.

BOLT SETS

T-nut TB

KS20, KS80, KSF80


M10

40

14

42

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

20

7,5

Hot dip galvanised after manufacture


TB

14 496 49

Installation examples
Profile AS

Ceiling support TP2


TP2
TB

T-nut TB is fastened in the slot of profile AS, TP or HK


by turning it clockwise 90.

VK

Wall support bracket VK is fastened onto a ceiling support


TP2 by using T-nut TB.

101.

BOLT SETS

Anchor rail nut AKM

KS20, KS80, KSF80

M 10 x 30

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

20

10

Hot dip galvanised after manufacture


AKM

14 496 83

Hot dip galvanised and painted after manufacture


PEX AKM

14 310 23

20

10

Installation examples
Allowed load

Fastening a wall support bracket to an anchor rail

TP2

AKM
VK

Maximum traction load F of sliding nut AKM is 800 kg.

A wall support bracket is fastened onto an anchor rail using


sliding bolt AKM.

102.

BOLT SETS

Nuts MU

Product

KS20, KS80, KSF80

SSTL
number

Package
pc

Weight kg
/100 pcs

Hot dip galvanised


MU M10 ZNK
MU M16 ZNK

14 491 66
14 491 67

100
100

1
3

Extension nuts JM

Product

KS20, KS80, KSF80

SSTL
number

Package
pc

Weight kg
/100 pcs

14 497 04
14 497 05

100
100

4
11

Zinc electroplated
JM M10
JM M16

Installation example
Extending a threaded rod
GT-10

JM M10

GT-10

Threaded rod GT can be extended using an extension nut.

103.

BOLT SETS

Bolt sets RS

Product

SSTL
number

KS20, KS80, KSF80

Package
pc

Weight kg
/100 pcs

Contents

Hot dip galvanised after manufacture


M6 + M6 x 12 hexagonal bolt
M8 + M8 x 40 hexagonal bolt
M8 + M8 x 70 hexagonal bolt
M10 + M10 x 30 hexagonal bolt

RS 1
RS 2
RS 3
RS KSF

14 496 97
14 496 98
14 496 99
14 491 15

20
10
10
20

1
2
3
3

Product

SSTL
number

Package
pc

Weight kg
/100 pcs

Contents

10
10
20

4
3
4

M8 + M8 x 80 lock bolt
M8 + M8 x 30 lock bolt
M10 + M10 x 40 lock bolt

Hot dip galvanised after manufacture


RS SSU
RS VK2
RS SMT

14 491 11
14 491 12
14 491 13

Address: Meka MekaJohtotiet Oy, Konetie 25, 90630 Oulu, Finland;


Tel. +358 8 5313100, Telefax +358 8 5313150; www.meka.net e-mail: meka@meka.net

104.