You are on page 1of 3

Finite element method

Problem 2: Distribution of temperature in the combustion chamber

Initial data:
1) Radial cross-cection of the combustion chamber

D1

D1
L1
L0
D3

2) Basic sizes
Variant
number

10

11

12

Basic sizes
D1, mm

500

525

550

575

600

625

650

675

700

725

750

775

D2, mm

250

262.5

275

287.5

300

312.5

325

337.5

350

362.5

375

387.5

D3, mm

100

105

110

115

120

125

130

135

140

145

150

155

L0, mm

600

630

660

690

720

750

780

810

840

870

900

930

L1, mm
Wall thickness,
mm

120

126

132

138

144

150

156

162

168

174

180

186

10

10

10

10

10

10

12

12

12

12

12

12

Burning zone:
length, mm

120

126

132

138

144

150

156

162

168

174

180

186

height, mm

75

78.75

82.5

86.25

90

93.75

97.5

101.25

105

108.75

112.5

116.25

Variant
number

13

14

15

16

17

18

19

20

21

22

23

24

Basic sizes
D1, mm

500

525

550

575

600

625

650

675

700

725

750

775

D2, mm

275

287.5

300

312.5

325

337.5

350

362.5

375

387.5

375

387.5

D3, mm

105

110

115

120

125

130

135

140

145

150

155

155

L0, mm

600

630

660

690

720

750

780

810

840

870

900

930

L1, mm
Wall thickness,
mm

132

138

144

150

156

162

168

174

180

186

180

186

10

10

10

10

10

10

12

12

12

12

12

12

Burning zone:
length, mm

120

126

132

138

144

150

156

162

168

174

180

186

height, mm

75

78.75

82.5

86.25

90

93.75

97.5

101.25

105

108.75

112.5

116.25

3) Temperature information
Variant
number

10

11

12

17

18

19

20

21

Air temperature, C
outer
Chamber
entree

10

11

12

13

near shaft

14

15

16

90

95

100

105

110

115

90

95

100

105

110

115

80

85

90

95

100

105

80

85

90

95

100

105

Temperature of contact surface


Inlet section
Outer contact

75

80

85

90

95

100

75

80

85

90

95

100

Inner contact

85

90

95

100

105

110

85

90

95

100

105

110

Outer contact

475

480

485

490

495

500

475

480

485

490

495

500

Inner contact

485

490

495

500

505

510

485

490

495

500

505

510

combustion
zone, C

1800

1805

1810

1815

1820

1825

1830

1835

1840

1845

1850

1855

13

14

15

16

17

18

19

20

21

22

23

24

Outlet section

Variant
number

Air temperature, C
outer
Chamber
entree

12

13

14

15

16

17

18

19

18

19

20

21

100

105

110

115

90

95

100

105

110

115

110

115

near shaft

80

85

90

95

100

105

80

85

90

95

100

105

Temperature of contact surface


Inlet section
Outer contact

75

80

85

90

95

100

75

80

85

90

95

100

Inner contact

85

90

95

100

105

110

85

90

95

100

105

110

Outlet section
Outer contact

475

480

485

490

495

500

475

480

485

490

495

500

Inner contact

485

490

495

500

505

510

485

490

495

500

505

510

combustion
zone, C

2200

2305

2210

2315

2220

2125

2130

2335

2140

2245

2350

2455

4) Siltuma vadmbas koeficientus


Materials
2

Thermal conductivity coefficients, W/m K

Al

Ti

Steel

Air

215

22

16

0.024