You are on page 1of 2

Nmero de medio -RENR2517-04

CALIBRATION WEIGHT
The items that are listed below can be used as calibration weights:
Solid Calibration Weight - Create a solid calibration weight by filling a concrete tube or a
steel tube with concrete of the dimensions listed in Illustration 1. This calibration weight
should weigh approximately 20 tons for the 992G and 30 tons for the 994 and 994D. Weigh
the weight on an accurate scale in order to determine the exact weight.

Refer to the table of weights for the calibration pipe for the dimensions.
(A) Diameter
(B) Length

Table 1
Approximate Calibration Pipe Weights
Model
992G
994
994D

Diameter and Length


"1.83 m 3.05 m (6 ft 10 ft)"
"
1.83 m 3.05 m (6 ft 16 ft)"

Weight
"
18690 kg (41200 lb) 20.6 Ton"
"
28150 kg (62000 lb) 31 Ton"

994F
High Lift
Extended High Lift
Super High Lift

"
2.14 m x 5.18 m (7 ft x 17 ft)"

994F
Standard Lift

"
"
2.14 m x 4.8 m (7 ft x 15.75 ft)"
38100 kg (83996 lb) 42 Ton"

"
35380 kg (78000 lb) 39 Ton"

Bucket Load of Material: - The material in the bucket of the loader is weighed on a truck
scale.
Bucket Load of Material - The material is weighed in an empty truck of known weight.
(This option can be used in order to obtain a weight if the loader cannot fit on the truck
scale.)