Professional Documents
Culture Documents
ATENTAMENTE
______________________________________________
M. EN I. HERIBERTO ENRIQUE CIRA GUERRA
ENSAYE:
MUNICIPIO:
MICHOACN.
ZINAPECUARO, MICHOACN
DATOS DEL
MUESTREO
BASE HIDRULICA
1673
1707
1820
HUMEDAD PTIMA;
12.4
1232
HUMEDAD NATURAL %
432/435
8.8
COMPOSICIN GRANULOMTRICA
TM 2
% RETENIDO
% PASA
RETENIDO 1
7.20
100
(76.00 mm)
100
(36.10 mm)
95
(25.40 mm)
86
3/4"
(19.06 mm)
77
3/8
(9.52 mm)
63
No. 4
(4.75 mm)
53
No. 10
(2.000 mm)
40
No. 20
(0.840 mm)
29
No. 40
(0.420 mm)
21
No. 60
(0.250 mm)
15
No.100
(0.149 mm)
No. 200
(0.074 mm)
100
MIN
6.60
DENSIDAD
2.20
40 MIN
109.0
V.R.S. (ESTNDAR) %
0.00
EXPANSIN (%)
VALOR CEMENTANTE Kg/Cm 2
79.60
LL
30
LP
IP
OBSERVACIONES, RECOMENDACIONES:
25 MAX
6 MAX
0.00
"GW"
CLASIFICACIN SUCS
ESPECIFICACIN SCT:
MATERIAL ANALIZADO PRESENTA CARACTERSTICAS FSICAS ACEPTABLES PARA SER UTILIZADO EN CAPAS DE BASE HIDRULICA
LABORATORISTA
V.O.B.O
LUGAR Y MUNICIPIO:
ZINAPECUARO, MICH.
BANCO
FECHA DE PRUEBA:
BASE HIDRULICA
COMPACTACIN DE PROYECTO %:
NUMERO DE
ENSAYE
ESTACIN
APROXIMADA
ESPESOR ACTUAL
ESPESOR DE
PESO
PESO
HUMEDAD PTIMA
HUMEDAD DEL
EN CMS.
PROYECTO EN
VOLUMTRICO
VOLUMTRICO
EN%
LUGAR EN %
% DE COMPACTACIN
CMS.
SECO MXIMO
BASE HIDRULICA
436
0+000
CENTRO
20.00
20.00
1721
1639
13.6
10.4
95
437
0+025
DERECHO
22.01
20.00
1721
1633
13.6
12.0
95
438
0+050
IZQUIERDO
23.05
20.00
1721
1676
13.6
12.0
97
439
0+053
CENTRO
20.08
20.00
1721
1659
13.6
11.6
96
OBSERVACIONES:
LUGAR Y MUNICIPIO:
ZINAPECUARO, MICH.
BANCO
FECHA DE PRUEBA:
SUB RASANTE
COMPACTACIN DE PROYECTO %:
NUMERO DE
ENSAYE
ESTACIN
LADO
ESPESOR ACTUAL
ESPESOR DE
PESO
PESO
HUMEDAD PTIMA
HUMEDAD DEL
EN CMS.
PROYECTO EN
VOLUMTRICO
VOLUMTRICO
EN%
LUGAR EN %
CMS.
SECO MXIMO
APROXIMADA
% DE COMPACTACIN
BASE HIDRULICA
436
0+000
CENTRO
35.00
30.00
437
0+025
DERECHO
33.00
30.00
438
0+050
IZQUIERDO
30.05
30.00
439
0+053
CENTRO
32.50
30.00
OBSERVACIONES: