You are on page 1of 2

10/05/2016

Comparison between LINDNER_Trituradora and Factory


NUPN

Name

Value of
LINDNER_Tritura
dora

Factory setting

Unit

01.07

Minimum reference clamp

750

02.04

Deceleration ramp mode select

Automatic ramp +

Automatic ramp

02.08

DC voltage threshold for auto. ramp

710

690

02.11

Acceleration rate 1

20

02.21

Deceleration rate 1

20

04.05

Motoring current limit

160

150

04.06

Regenerating Current Limit

160

110

04.07

Symetric Current Limit

160

110

05.07

Motor rated current

240

350

05.08

Motor rated speed

988

1480

rpm

05.10

Rated power factor

0.84

0.85

05.14

Open loop mode selection

Rs not measured

Rs measured after each power u

05.15

Low frequency voltage boost

05.17

Stator resistance

14.46

mO

05.23

Voltage offset

3.9

06.01

Stop mode

Coast

Ramp

06.12

Keypad stop key

Disabled

Enabled

07.20

AO1 Analog Output 1 scale

22.26

Calculated motor power factor

22.36

SELECT LANGUAGE

ESPANOL

FRANCAIS

23.02

Numro de srie 2

23.11

Pass

Number of line

rpm

22

You might also like