Professional Documents
Culture Documents
Why overhauling is
required ??
Motor details
Plant-EC
Tag No-P702 B
Make-Siemens
Sr. no-13157
KW-22
RPM-1460
FLA-40 A
Overhauling Procedure
Receive work order for the motor
Check if any abnormalities is mentioned.
IR at Megger voltage
500 V :IR in
megaohms
R-E
400
Y-E
400
B-E
400
R-Y
400
Y-B
500
B-R
500
Winding impedance
readings :Windings
Resistance
(ohms)
Inductance
(mH)
0.50
2.7
0.45
2.3
0.50
2.7
Bearing dismounting
Methods
Cold dismounting
Hydraulic puller
Mechanical puller
Hot dismounting
Using Induction heater
50.015
50.005
90
90.035
90.002
(NDE)
Housing
(DE)
Bearing mounting
Methods
Cold mounting
With hammer
Using metal blocks
Hot mounting
Induction heater
Induction plate
Oil bath
Hot mount
Final tests
No load test (check IR value before
the tests)
Vibration analysis
Mechanical integrity
Axial play
Radial play
Run out
Vibration Analysis
THANK YOU