PRECONCO LIMITED

Leaders in Precasting

!
24th July 2015

IBI GROUP ARCHITECTS


7th Floor - 55 St. Clair Avenue West
Toronto ON
M4V 2Y7
Canada

!!
!

Re: Motor Vehicle Authority Head Office and Access Centre - Proposed Gym Equipment
With regard to the proposed gym equipment installation for the Motor Vehicle Authority Head Office and Access
Centre, I can confirm that in this area the floor and beams were designed for a live load of 5.0 kN/m2 (500 kg/
m2). The heaviest piece of equipment proposed is less than 350kg in over 2m2 surface. I trust that this
information meets with your requirements in this instance.

!!
!

Yours Faithfully

!
!

George McAllister BEng(Hons) CEng MIEI MBAPE


For and on behalf of Preconco Ltd.

P.O. Box 576. Lears Quarry, St Michael, Barbados.


Tel (246) 430-0371 *
Fax (246) 228-9361 * E-mail: preconco@sunbeach.net