You are on page 1of 2

KLINGERexpert 5.2.

1
gasket calculation
Bolt characteristics

Gasket conditions

Number
Quality

12
8.8

Material

0.2 % Creep limit


Size

Service conditions

Automatic choice

640.00

MPa

Thickness

M-20

Temperature

0.14

Torque

291.99 Nm

Total Area

68519

mm

Aggregate state

116113

mm

Medium
Totals formula

Gasket stress
Bolt force properties
Max. bolt load

156.8

Yield

kN

50 %

Bolt force

78.4 kN

Total bolt force

940.8

DN 300

Nominal pressure

PN 10

174

MPa

VU

MPa

MPa

BU

MPa

-1

MPa

kN

Flange Dimension
Nominal diameter

BO

E min

eff

14

MPa

VO

180

MPa

MPa

relax

5.0 bar

Concentration

mm

Compr. Area

Friction

Pressure

KLINGERQuantum
2.0

30 C

100 %
liquid
Water

H2 O

Leakage
20C

0.025

mg/sm

TC

0.011

mg/sm

DIN Leakage
20C

TC

Tightness class
acc.DIN 28090
L0.01
acc.DIN 3535

0.896 mg/sm
L0.1

L1.0

10.000 ml/min

Graphical analysis of gasket stress


Database version 15.04.2014
0

0
VU

BU
VO

eff
Emin
Installation conditions

BO
eff
Operating conditions

Visit Klinger Homepage


.

Gasket dimension
Thickness
Outside diameter
Outside diameter ( compr. )
Inside diameter ( compr. )
Compressed gasket area
Pressurized area
Hole diameter

2.00
445
445
324
68519
116113
22.0

mm
mm
mm
mm
mm
mm
mm

Info
Media resistance to Water is good.

Maximum allowed temperature is 300C.

You have chosen a flange of type EN.


Please consider that high bolt forces can lead to bending of the flanges.
The KLINGERexpert software makes a theoretical assumption that flanges are rigid.
Find further informations under Help/About/Klinger Homepage.

Disclaimer...
The characteristic values on which the gasket calculations are based have been derived from the latest research in the Klinger laboratories and to the best of our knowledge and judgement.
Further investigations in this field will make future updates of the calculational values and procedures possible.
The values and parameters calculated with KLINGERexpert are based on a static calculation of the information provided, such as temperature, pressure, bolt loads, etc.
An explicit calculation of the actual conditions, which takes account of plant-specific boundary conditions, such as load change behaviour, additional piping forces, flange bending, etc., is not
possible because of the complexity of the relationships.
For these reasons, the establishment of any guarantee claims, of any nature whatsoever, for the functionality of flange connections with gaskets which are calculated with KLINGERexpert is not

possible.

Additional information
Bitte geben Sie hier Ihren Text ein
Insert your text here.

You might also like