You are on page 1of 105

N-0

Course Name

WCDMA Handover
Principle and
Relevant Parameters
www.huawei.com

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Confidential Information of Huawei. No Spreading Without Permission

N-1

Course Name

Foreword


Why mobile systems need handover?




It is decided by the characters of mobile system:




The mobility of UE

The mobile system is composed by cells which the coverage


ability is limited.

Providing the continuous service in mobile system is the basic


element in QoS.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page1

Confidential Information of Huawei. No Spreading Without Permission

N-2

Course Name

Objectives


Upon completion of this course, you will be able to:




Know the basic definitions of Handover

The algorithms of handover decision

The handover flow

The parameters of handover

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page2

Confidential Information of Huawei. No Spreading Without Permission

N-3

Course Name

Contents
1. Introduction of Handover
2. Measurement of Handover
3. The Basic Handovers

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page3

Confidential Information of Huawei. No Spreading Without Permission

N-4

Course Name

Contents
1. Introduction of Handover
2. Measurement of Handover
3. The Basic Handovers

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page4

Confidential Information of Huawei. No Spreading Without Permission

N-5

Course Name

The Purpose of Handover




Providing the continuous service in mobile system is the


basic element in QoS

The load balance: sharing the resource

The hierarchy divided by speed and service: high efficiency


of using resource

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page5

Handover is a basic function of a cellular mobile network. The purpose of handover is


to ensure that a UE in CELL_DCH state is served continuously when it moves.

Confidential Information of Huawei. No Spreading Without Permission

N-6

Course Name

The Basic Concepts of Handover




Active Set

maximum ratio combination

Monitored Set

selection combination

Detected set

The soft handover gain

Radio Link (RL)

CPICH

Radio Link Set


(RLS)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page6

Active set : Cells, which belong to the active set. User information is sent from all these cells.
In FDD, the cells in the active set are involved in soft handover. In TDD the active set always
comprises one cell only. The UE shall only consider active set cells included in the variable
CELL_INFO_LIST for measurement; i.e. active set cells not included in the CELL_INFO_LIST
shall not be considered in any event evaluation and measurement reporting.

Monitored set :Cells, which are not included in the active set, but are included in the
CELL_INFO_LIST belong to the monitored set.

Detected set : Cells detected by the UE, which are neither in the CELL_INFO_LIST nor in the
active set belong to the detected set. Reporting of measurements of the detected set is only
applicable to intra-frequency measurements made by UEs in CELL_DCH state.

RL: Radio link between NodeB and UE.

RLS: Radio link set. The RLs from same NodeB.

Combination way: For soft handover, the uplink signals are combined in RNC. The RNC will
select one best signal to process. We call this selective combination. For softer handover, the
uplink signals are combined in the RAKE receiver of NodeB. It is maximum ratio combination.

Soft handover gain: We have introduced in Coverage Planning.

CPICH: Common Pilot Channel. UE measure the signal strength of CPICH for handover
decision.

Confidential Information of Huawei. No Spreading Without Permission

N-7

Course Name

The Categories of Handover




According to the signaling characters




Soft handover (softer handover)

Hard handover

According to the properties of source cell and target cell:




Intra-frequency handover

Inter-frequency handover

Inter-RAT handover (UMTS GSM/GPRS)

According to the purpose of handover:




Based on Coverage

Based on Noncoverage

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page7

The unique signaling of soft handover is Active Set Update, and the unique signaling
of hard handover is Physical Channel Reconfiguration.

Soft handover include soft handover and softer handover. It is depended on if the two
(or three) RLs belong to one NodeB.

The handover based on load is load control algorithm.

The handover based on mobility of UE is for HCS handover.

The handover based on service: for example, the handover between R99 and
HSDPA.

Confidential Information of Huawei. No Spreading Without Permission

N-8

Course Name

The Characters of Different Handover




Comparison between soft handover and hard handover:

Item
The number of RLs in

Soft Handover

Hard Handover

Several

One

No

Yes

Only happened

Can be happened in Intra-

between Intra-

frequency cells or Inter-frequency

frequency cells

cells

active set after handover


Interruption during
handover
The frequencies of cells

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page8

The maximum number of RL is 3. This value can be changed. But this function need
the UE to support. Normally, the active set supported by UE is fixed 3 and can not be
changed.

Confidential Information of Huawei. No Spreading Without Permission

N-9

Course Name

The Characters of Different Handover




Comparison between soft handover and softer handover :

Item
UL combination

Soft Handover

Softer Handover

Signal combined in

Signal combined in NodeB by

RNC by selective

maximum ratio combination

combination
DL combination

Signal combined in

Signal combined in UE by

UE by maximum ratio

maximum ratio combination

combination

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page9

During softer handover, the uplink signaling are combined in


NodeB by maximum ratio combination, but during soft
handover they are combined in RNC by selective
combination
Compare to later one, the maximum ratio combination can
get more gain. So the performance of maximum ratio
combination is better
Since softer handover is completed in NodeB, it do not
consume transport resource of Iub

Confidential Information of Huawei. No Spreading Without Permission

N-10

Course Name

Soft Handover
RNC

NodeB 1

NodeB 2

Cell A

Cell B

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page10

It is soft handover. During the handover, two radio links are connected with UE, and
data in each RL are same. So the UE can combine the data in RAKE receiver. But the
control part are different for downlink.

Confidential Information of Huawei. No Spreading Without Permission

N-11

Course Name

Softer Handover
RNC

NodeB

Cell A
Cell B

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page11

It is softer handover. The cells in active set belong to one NodeB. The NodeB use the
RAKE receiver to combine the data in HULP board. Then send the data to WFMR
board in RNC.

Confidential Information of Huawei. No Spreading Without Permission

N-12

Course Name

Hard Handover
RNC

NodeB 1

NodeB 2

Cell A

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Cell B

Page12

It is hard handover. The UE disconnect the original radio link, then connect to the
target cell. It happened in intra-frequency, inter-frequency and inter-RAT.

Confidential Information of Huawei. No Spreading Without Permission

N-13

Course Name

Three Steps of Handover


The following figure shows handover
procedure (measurement quality set to
PCPICH Ec/No)
Measure the CPICH Ec/N0 of the serving cell and
its neighboring cells as well as the relative time
difference between the cells

Measurement

Measurement phase

Decision

No
Are handover criteria satisfied?

Yes

Execution

Perform a handover and update relative parameters

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Decision phase

Execution phase

Page13

In the measurement phase, the UE takes measurement according to the


MEASUREMENT CONTROL message received from the RNC. The UE sends related
measurement reports to the RNC according to the rules defined in the
MEASUREMENT CONTROL message when the event triggering conditions are met.

After receiving the intra-frequency measurement report from the UE, the RNC decides
whether to go to the execution phase, depending on the information in the report.

Confidential Information of Huawei. No Spreading Without Permission

N-14

Course Name

Contents
1. Introduction of Handover
2. Measurement of Handover
3. The Basic Handovers

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page14

Confidential Information of Huawei. No Spreading Without Permission

N-15

Course Name

Contents
2. Measurement of Handover
2.1 Measurement Control and Measurement Report
2.2 Measurement Phase

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page15

Confidential Information of Huawei. No Spreading Without Permission

N-16

Course Name

Measurement Control

UE

UTRAN

MEASUREMENT CONTROL

Measurement Control, normal case

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page16

If the UE setup a RRC connection or trigger the 1D event, the UTRAN will send the measurement
control to UE. The measurement control include the algorithm of measurement and handover, for
example, the intra-frequency handover criteria, and how to report.

The latter message includes the following measurement control information:

1. Measurement identity: A reference number that should be used by the UTRAN when setting
up, modifying or releasing the measurement and by the UE in the measurement report.

2. Measurement command: One out of three different measurement commands.

-Setup: Setup a new measurement.

-Modify: Modify a previously defined measurement, e.g. to change the reporting criteria.

-Release: Stop a measurement and clear all information in the UE that are related to that
measurement.

3. Measurement type: One of the types listed above describing what the UE shall measure.
Presence or absence of the following control information depends on the measurement type.

4. Measurement objects: The objects the UE shall measure, and corresponding object
information.

5. Measurement quantity: The quantity the UE shall measure. This also includes the filtering of
the measurements.

6. Reporting quantities: The quantities the UE shall include in the report in addition to the
quantities that are mandatory to report for the specific event.

7. Measurement reporting criteria: The triggering of the measurement report, e.g. periodical or
event-triggered reporting.

8. Measurement Validity: Defines in which UE states the measurement is valid.


9. Measurement reporting mode: This specifies whether the UE shall transmit the measurement
report using AM or UM RLC.

10. Additional measurement identities: A list of references to other measurements. When this
measurement triggers a measurement report, the UE shall also include the reporting quantities for the
measurements referenced by the additional measurement identities.

Confidential Information of Huawei. No Spreading Without Permission

N-17

Course Name

Measurement Report

UE

UTRAN

MEASUREMENT REPORT

Measurement Control, normal case

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page17

The purpose of the measurement reporting procedure is to transfer

measurement results from the UE to UTRAN.




Based on the algorithm in measurement control, the UE will measure the

signal strength and check if it meet the requirement of all event. If it meet the
requirement of any event, UE will send the measurement report to UTRAN to
trigger the handover. The most important information in the measurement are
the PSC and the CPICH Ec/No of the target cell, and the triggered event.

Confidential Information of Huawei. No Spreading Without Permission

N-18

Course Name

Contents
2. Measurement of Handover
2.1 Measurement Control and Measurement Report
2.2 Measurement Phase

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page18

Confidential Information of Huawei. No Spreading Without Permission

N-19

Course Name

Measurement Model
parameters

parameters

Layer 1
filtering

Layer 3
filtering

C
C'

Evaluation
of reporting
criteria

A is measurement value at the physical layer

B is the measurement value after layer 1 filtering at physical layer.


The value goes from the physical layer to high layer

C is measurement after processing in the layer3 filter

C is another measurement value

D is measurement report information sent on the radio interface or


Iub interface

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page19

Confidential Information of Huawei. No Spreading Without Permission

N-20

Course Name

Measurement Quantity

Ec/No


RSCP


CPICH signal quality

CPICH signal level

RSSI


GSM cell signal level

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page20

The measurement quantity of intra-frequency or inter-frequency measurement can be


Ec/No (dB) or RSCP (dBm) of a common pilot channel .
For inter-RAT measurement ,GSM cell RSSI is used.

Confidential Information of Huawei. No Spreading Without Permission

N-21

Course Name

Measurement Quantity Configuration


IntraFreqMeasQuantity

Parameter name: Intra-frequency measure quantity

The default value of this parameter is Ec/No

InterFreqMeasQuantity

Parameter name: Inter-frequency measure quantity

The default value of this parameter is Both

MeasQuantityOf3A

Parameter name: 3A Measure Quantity

The default value of this parameter is RSCP

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page21

IntraFreqMeasQuantity

Parameter name: Intra-frequency measurement quantity

Value range: CPICH_Ec/No, CPICH_RSCP .

Content: Measurement value used in intrafrequency measurement .

The recommended value of this parameter is CPICH_EC/NO

Set this parameter through SET INTRAFREQHO, query it through LST


INTRAFREQHO.


InterFreqMeasQuantity

Parameter name: Inter-frequency measurement quantity

Value range: CPICH_Ec/No, CPICH_RSCP, BOTH .

Content: Measurement quantity used in coverage-based inter-frequency


measurement .

The recommended value of this parameter is BOTH.

Set this parameter through SET INTERFREQHOCOV, query it through LST


INTERFREQHOCOV.


MeasQuantityOf3A

Parameter name: 3A Measure Quantity

Value range: CPICH_Ec/No, CPICH_RSCP.

Content: Measurement quantity used in coverage-based inter-RAT measurement .

The recommended value of this parameter is CPICH_RSCP.

Set this parameter through SET INTERRATHOCOV, query it through

SET INTERRATHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-22

Course Name

Layer 3 filtering
Fn = (1 a ) Fn 1 + a M n
Where:


Fn is the new measurement value after filtering.

Fn-1 is the last measurement value after filtering.

Mn is the latest measurement value from the physical layer.

a = 1/2(k/2)

(k is set to Intra-freq meas L3 filter coeff)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page22

The greater this parameter is ,the stronger the smoothing effect on the signal will be ,
and the stronger the fast fading resistance capability will be , but the weaker the
tracing capability of the signal change will be.
 When k = 0, that is, a is set to 1, no layer 3 filtering is performed.

Confidential Information of Huawei. No Spreading Without Permission

N-23

Course Name

Layer 3 filtering coefficient




FilterCoef


Parameter name: Intra-frequency measurement filter coefficient

The default value of this parameter is D3

InterFreqFilterCoef


Parameter name: Inter-frequency measure filter coefficient

The default value of this parameter is D3

InterRATFilterCoef


Parameter name: Inter-RAT filter coefficient

The default value of this parameter is D3

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page23

FilterCoef

Parameter name: Intra-frequency measurement filter coefficient

Value range: 0~19.

Content: L3 filtering coefficient for intra-frequency measurement. The greater this parameter is, the greater the
smoothing effect and the higher the anti fast fading capability, but the lower the signal change tracing capability.

The recommended value of this parameter is 3

Set this parameter through SET INTRAFREQHO, query it through LST INTRAFREQHO.

InterFreqFilterCoef

Parameter name: Inter-frequency measurement filter coefficient

Value range: 0~19.

Content: L3 filtering coefficient for intra-frequency measurement. The greater this parameter is, the greater the
smoothing effect and the higher the anti fast fading capability, but the lower the signal change tracing capability.

The recommended value of this parameter is 3

Set this parameter through SET INTERFREQHOCOV, query it through LST INTERFREQHOCOV.

InterRATFilterCoef

Parameter name: Inter-RAT measurement filter coefficient

Value range: 0~19.

Content: L3 filtering coefficient for intra-frequency measurement. The greater this parameter is, the greater the
smoothing effect and the higher the anti fast fading capability, but the lower the signal change tracing capability.

The recommended value of this parameter is 3

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-24

Course Name

Measurement Report Mode




Periodic Report

Event Trigger Report

Event to Periodic Report

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page24

According to the Measurement Control , UE will report the measurement results to


UTRAN by event trigger report or periodic report.
If the UE report a measurement report triggered by Event ,the UE will wait for response
from UTRAN, if there is no any response after a specific period, to avoid
measurement report loss, the event reporting can be turned to periodical report.

Confidential Information of Huawei. No Spreading Without Permission

N-25

Course Name

Contents
1. Introduction of Handover
2. Measurement of Handover
3. The Basic Handovers

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page25

Confidential Information of Huawei. No Spreading Without Permission

N-26

Course Name

Contents
3. The Basic Handovers
3.1 Soft Handover
3.2 Intra-frequency Hard Handover
3.3 Inter-frequency Hard Handover
3.4 Inter-RAT Hard Handover
3.5 Blind Handover

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page26

Confidential Information of Huawei. No Spreading Without Permission

N-27

Course Name

Contents
3. The Basic Handovers
3.1 Soft Handover
3.2 Intra-frequency Hard Handover
3.3 Inter-frequency Hard Handover
3.4 Inter-RAT Hard Handover
3.5 Blind Handover

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page27

Confidential Information of Huawei. No Spreading Without Permission

N-28

Course Name

Brief Introduction of Soft Handover




Characters of Soft Handover




During handover, UE has several RLs with different cells

The handover among different cells which are in same RLS can be
softer handover

Signals from each RL will be combined in UL and DL.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page28

Soft handover:

selective combination in uplink


Maximum ratio combination in downlink


Softer handover

Maximum ratio combination in uplink and downlink

Confidential Information of Huawei. No Spreading Without Permission

N-29

Course Name

Brief Introduction of Soft Handover




Advantages


Soft handover gain

Decrease the possibility of call drop

Disadvantages


More resource needed in downlink

it way cause side-effect

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page29

Advantages

Because of the signal combination, the combination gain can overcome some of the path
loss
During the handover, UE has several RLs with the network, call drop caused by pingpong handover can be avoided

Disadvantages

Soft handover will occupy more resource ,such as CE, Iub transmission, especially for
the code resources for BE service
When the downlink power from different cells are not balanced, it will cause side-effect in
downlink.

Confidential Information of Huawei. No Spreading Without Permission

N-30

Course Name

Measurement of Soft Handover




Measurement quantity


CPICH RSCP

CPICH Ec/No

Reporting mode


Periodic reporting

Event trigger reporting

Event trigger reporting to Periodic reporting

Event type


1A,1B,1C,1D,1F

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page30

Normally, the soft handovers are triggered by 1A,1B,1C events in the Measurement
report signaling, UTRAN will make decisions according to these events
1D event will trigger new measurement control.

Confidential Information of Huawei. No Spreading Without Permission

N-31

Course Name

Soft Handover Measurement Events


Event
1A

Description
The PCPICH quality of the cells in the monitored set enters the reporting range .
This indicates that the quality of a cell is close to the quality of the best cell . A
relative high combined gain can be achieved when the cell is added to the active
set

1B

The PCPICH quality of the cells in the active set leaves the reporting range. This
indicates that quality of a cell is much worse than the quality of the best cell. The
cell should not stay in the active set

1C

A non-active PCPICH becomes better than an active PCPICH. This indicates that
the quality of a cell is close to the quality of the best cell. In addition ,the number of
cells in the active set has reached the maximum value. The cell replaces the worst
cell in the active set ; thus achieving a higher combined gain

1D

Event of the change of the best cell

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page31

Actually ,we can consider Events are the suggestions from the UE:
1A means UE suggests to add a radio link,
1B means UE suggests to remove a radio link,
1C means UE suggests to exchange a radio link

Confidential Information of Huawei. No Spreading Without Permission

N-32

Course Name

The Trigger Algorithm of 1A Event




Event 1A is triggered on the basis of the following formula

10 LogM

New

NA

+ CIO New W 10 Log M i + (1 W ) 10 LogM


i =1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.




Best

( R1a H 1 a / 2 ),

Page32

Mnew is the measurement value of the cell in the reporting range


CIOnew is cell individual offset of the cell in the reporting range . It is set
for the neighboring cell

W is the weight value

Mi is the measurement value of the cell in the active set

NA is the number of cells in the current active set

Mbest is the measurement value of the best cell in the active set

R1a is the reporting range or relative threshold of soft handover. The threshold
parameters of CS and PS service are CS service 1A event relative
threshold , PS service 1A event relative threshold respectively
H1a is 1A hysteresis , the hysteresis value of event 1A

Confidential Information of Huawei. No Spreading Without Permission

N-33

Course Name

Example of 1A Event

A: signal curve of the best cell in the active set


B: signal curve of a cell in the monitoring set
C: The 1A curve

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page33

Confidential Information of Huawei. No Spreading Without Permission

N-34

Course Name

Key parameters of 1A Event


INTRARELTHDFOR1ACS

Parameter name: CS service 1A event relative threshold

The default value of this parameter is 6 ( 3dB )

INTRARELTHDFOR1APS

Parameter name: PS service 1A event relative threshold

The default value of this parameter is 6 ( 3dB )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page34

INTRARELTHDFOR1ACS


Parameter name: CS service 1A event relative threshold

Value range: 0~14.5; step: 0.5

Content: The CS service relative threshold of the event 1A. It is easier to

trigger event 1A if the value increases. It is harder to trigger event 1A if the


value decreases.


The recommended value of this parameter is 6 (3dB)

Set this parameter through SET INTRAFREQHO, query it through LST

INTRAFREQHO.

INTRARELTHDFOR1ACS


Parameter name: PS service 1A event relative threshold

Value range: 0~14.5; step: 0.5

Content: The PS service relative threshold of the event 1A. It is easier to

trigger event 1A if the value increases. It is harder to trigger event 1A if the


value decreases.


The recommended value of this parameter is 6 (3dB)

Set this parameter through SET INTRAFREQHO, query it through LST

INTRAFREQHO.

Confidential Information of Huawei. No Spreading Without Permission

N-35

Course Name

Key parameters of 1A Event


HYSTFOR1A

Parameter name: 1A event hysteresis

The default value of this parameter is 0( 0dB )

TRIGTIME1A

Parameter name: 1A event trigger delay time

The default value of this parameter is D320 ( 320ms )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page35

HYSTFOR1A


Parameter name: 1A event hysteresis

Value range: 0~7.5dB; step: 0.5

Content: The hysteresis value of the event 1A. This parameter value is
related to the slow fading characteristic. The greater this parameter is set, the
less ping-pong effect and misjudgement can be caused. However, in this case,
the event cannot be triggered in time.

The recommended value of this parameter is 0 ( 0dB )

Set this parameter through SET INTRAFREQHO, query it through LST

INTRAFREQHO.

TRIGTIME1A


Parameter name: 1A event trigger delay time

Value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280,

2560, 5000 ms
Content: The trigger delay time of the event 1A. This parameter value is
related to the slow fading characteristic. The greater this parameter is set, the
smaller the misjudgement probability, but the lower the response speed of the
event to the measured signal changes.

The recommended value of this parameter is D320 ( 320ms )

Set this parameter through SET INTRAFREQHO, query it through LST

INTRAFREQHO.

Confidential Information of Huawei. No Spreading Without Permission

N-36

Course Name

The Trigger Algorithm of 1B Event




Event 1B is triggered on the basis of the following formula

NA

10 LogM Old + CIOOld W 10 Log M i + (1 W ) 10 LogM Best ( R1b + H 1b / 2),


i =1

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.




Page36

Mold is the measurement value of the cell that becomes worse


CIOold is cell individual offset of the cell in the reporting range . It is set for
the neighboring cell

W is the weight value

Mi is the measurement value of the cell in the active set

NA is the number of cells in the current active set

Mbest is the measurement value of the best cell in the active set

R1b is the reporting range or relative threshold of soft handover. The threshold
parameters of CS and PS service are CS service 1B event relative
threshold , PS service 1B event relative threshold respectively
H1b is 1B hysteresis , the hysteresis value of event 1B

Confidential Information of Huawei. No Spreading Without Permission

N-37

Course Name

Example of 1B Event

A: signal curve of the best cell in the active set


B: signal curve of a cell in the monitoring set
C: The 1B curve

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page37

Confidential Information of Huawei. No Spreading Without Permission

N-38

Course Name

Key parameters of 1B Event


INTRARELTHDFOR1BCS

Parameter name: CS service 1B event relative threshold

The default value of this parameter is 12 ( 6dB )

INTRARELTHDFOR1BPS

Parameter name: PS service 1B event relative threshold

The default value of this parameter is 12 ( 6dB )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page38

INTRARELTHDFOR1BCS


Parameter name: CS service 1B event relative threshold

Value range: 0~14.5; step: 0.5

Content: The CS service relative threshold of the event 1B. It is easier to

trigger event 1B if the value decreases. It is harder to trigger event 1B if the


value increases.


The recommended value of this parameter is 12 (6dB)

Set this parameter through SET INTRAFREQHO, query it through LST

INTRAFREQHO.

INTRARELTHDFOR1BCS


Parameter name: PS service 1B event relative threshold

Value range: 0~14.5; step: 0.5

Content: The PS service relative threshold of the event 1B. It is easier to

trigger event 1B if the value increases. It is harder to trigger event 1B if the


value decreases.


The recommended value of this parameter is 12 (6dB)

Set this parameter through SET INTRAFREQHO, query it through LST

INTRAFREQHO.

Confidential Information of Huawei. No Spreading Without Permission

N-39

Course Name

Key parameters of 1B Event


HYSTFOR1B

Parameter name: 1B event hysteresis

The default value of this parameter is 0( 0dB )

TRIGTIME1B

Parameter name: 1B event trigger delay time

The default value of this parameter is D640 ( 640ms )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page39

HYSTFOR1B


Parameter name: 1B event hysteresis

Value range: 0~7.5dB; step: 0.5

Content: The hysteresis value of the event 1B. This parameter value is
related to the slow fading characteristic. The greater this parameter is set, the
less ping-pong effect and misjudgement can be caused. However, in this case,
the event cannot be triggered in time.

The recommended value of this parameter is 0 ( 0dB )

Set this parameter through SET INTRAFREQHO, query it through LST

INTRAFREQHO.

TRIGTIME1B


Parameter name: 1B event trigger delay time

Value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280,

2560, 5000 ms
Content: The trigger delay time of the event 1B. This parameter value is
related to the slow fading characteristic. The greater this parameter is set, the
smaller the misjudgement probability, but the lower the response speed of the
event to the measured signal changes.

The recommended value of this parameter is D640 ( 640ms )

Set this parameter through SET INTRAFREQHO, query it through LST

INTRAFREQHO.

Confidential Information of Huawei. No Spreading Without Permission

N-40

Course Name

The Trigger Algorithm of 1C Event




Event 1C is triggered on the basis of the following formula

10 LogM New + CIONew 10 LogM InAS + CIOInAS + H1c / 2,

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.




Page40

Mnew is the measurement value of the cell in the reporting range


CIOnew is cell individual offset of the cell in the reporting range . It is set
for the neighboring cell

M inAS is the measurement value of the worst cell in the active set

CIOInAS is cell individual offset of the worst cell in the active set

H1c is 1C hysteresis , the hysteresis value of event 1C

Confidential Information of Huawei. No Spreading Without Permission

N-41

Course Name

Example of 1C Event

A: signal curve of the best cell in the active set


B: signal curve of a cell in the active set
C: signal curve of the worst cell in the active set
D: signal curve of a cell in the monitoring set
E: The 1C curve
Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page41

Confidential Information of Huawei. No Spreading Without Permission

N-42

Course Name

Key parameters of 1C Event


HYSTFOR1C

Parameter name: 1C event hysteresis

The default value of this parameter is 8( 4dB )

TRIGTIME1C

Parameter name: 1C event trigger delay time

The default value of this parameter is D640 ( 640ms )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page42

HYSTFOR1C


Parameter name: 1C event hysteresis

Value range: 0~7.5dB; step: 0.5

Content: The hysteresis value of the event 1C. This parameter value is
related to the slow fading characteristic. The greater this parameter is set, the
less ping-pong effect and misjudgement can be caused. However, in this case,
the event cannot be triggered in time.

The recommended value of this parameter is 8 ( 4dB )

Set this parameter through SET INTRAFREQHO, query it through LST

INTRAFREQHO.

TRIGTIME1C


Parameter name: 1C event trigger delay time

Value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280,

2560, 5000 ms
Content: The trigger delay time of the event 1C. This parameter value is
related to the slow fading characteristic. The greater this parameter is set, the
smaller the misjudgement probability, but the lower the response speed of the
event to the measured signal changes.

The recommended value of this parameter is D640 ( 640ms )

Set this parameter through SET INTRAFREQHO, query it through LST

INTRAFREQHO.

Confidential Information of Huawei. No Spreading Without Permission

N-43

Course Name

The Trigger Algorithm of 1D Event




Event 1D is triggered on the basis of the following formula

10 LogM New 10 LogM InAS + H1c / 2,

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page43

MNotbest is the measurement value of a cell that is not best cell

M inAS is the measurement value of the worst cell in the active set

H1d is 1D hysteresis , the hysteresis value of event 1D

Confidential Information of Huawei. No Spreading Without Permission

N-44

Course Name

Example of 1D Event

A: signal curve of the best cell in the active set


B: signal curve of a cell in the active set or monitoring set
C: Th1D curve

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page44

Confidential Information of Huawei. No Spreading Without Permission

N-45

Course Name

Key parameters of 1D Event


HYSTFOR1D

Parameter name: 1D event hysteresis

The default value of this parameter is 8( 4dB )

TRIGTIME1D

Parameter name: 1D event trigger delay time

The default value of this parameter is D640 ( 640ms )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page45

HYSTFOR1D


Parameter name: 1D event hysteresis

Value range: 0~7.5dB; step: 0.5

Content: The hysteresis value of the event 1D. This parameter value is
related to the slow fading characteristic. The greater this parameter is set, the
less ping-pong effect and misjudgement can be caused. However, in this case,
the event cannot be triggered in time.

The recommended value of this parameter is 8 ( 4dB )

Set this parameter through SET INTRAFREQHO, query it through LST

INTRAFREQHO.

TRIGTIME1D


Parameter name: 1D event trigger delay time

Value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280,

2560, 5000 ms
Content: The trigger delay time of the event 1D. This parameter value is
related to the slow fading characteristic. The greater this parameter is set, the
smaller the misjudgement probability, but the lower the response speed of the
event to the measured signal changes.

The recommended value of this parameter is D640 ( 640ms )

Set this parameter through SET INTRAFREQHO, query it through LST

INTRAFREQHO.

Confidential Information of Huawei. No Spreading Without Permission

N-46

Course Name

Other key parameters for SHO


Weight

Parameter name: Weighted factor

The default value of this parameter is 0

SHOQualmin

Parameter name: Min quality THD for SHO

The default value of this parameter is -24(-24 dB)

CELLINDIVIDALOFFSET

Parameter name: Cell offset

The default value of this parameter is 0 ( 0dB )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page46

Weight




Parameter name: Weighted factor

Value range: 0~2

Content: This parameter is used to define the soft handover relative threshold based
on the measured value of each cell in the active set. The greater this parameter is set,
the higher the soft handover relative threshold. When this parameter is set as 0, the
soft handover relative threshold is only for the best cell in the active set.

The recommended value of this parameter is 0.

Set this parameter through SET INTRAFREQHO, query it through LST INTRAFREQHO.

SHOQualmin

Parameter name: Min quality THD for SHO

Value range: -24~0;

Content: minimum quality threshold for soft handover .

The recommended value of this parameter is -24 (-24dB)

Set this parameter through SET INTRAFREQHO, query it through LST INTRAFREQHO.

CELLINDIVIDALOFFSET




Parameter name: Cell offset

Value range: -10~10 dB;

Content: Offset of cell CPICH measurement value. The offset is added to the
measurement quantity before the UE evaluates if an event has occurred. In handover
algorithms, this parameter is used for moving the border of a cell.

The recommended value of this parameter is 0 (0dB)

Set this parameter through ADD INTRAFREQNCELL, query it through LST

INTRAFREQNCELL.

Confidential Information of Huawei. No Spreading Without Permission

N-47

Course Name

Contents
3. The Basic Handovers
3.1 Soft Handover
3.2 Intra-frequency Hard Handover
3.3 Inter-frequency Hard Handover
3.4 Inter-RAT Hard Handover
3.5 Blind Handover

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page47

Confidential Information of Huawei. No Spreading Without Permission

N-48

Course Name

Brief Introduction of Intra-Frequency Handover




Characters of Intra-Frequency Handover




During handover, UE has only one RL with one cell

Switch off the RL with the original cell, then setup the RL with target
cell

The frequency of source cell and target cell are same

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page48

In some cases ,UE want to take soft handover according to the intra-frequency
measurement, but RNC dont allow the UE to take this soft handover cause there is
no IUR interface between 2 RNCs or the service rate is higher than a threshold, then
the UE has to ask for hard handover based on the measurement.

During the intra-frequency hard handover, the RNC will ask the UE to switch off the
RL with the original cell and setup the RL with the target cell, so there is a gap during
this procedure.

Intra-Frequency Handover is always triggered by 1D event.

Confidential Information of Huawei. No Spreading Without Permission

N-49

Course Name

Brief Introduction of Intra-Frequency Handover




Advantages


Enhance the usage efficiency of the OVSF code and hardware

Disadvantages


High call drop possibility because of the intra-frequency


interference

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page49

Cause there is only 1 RL for the UE, OVSF code resources ,CE resources DL tx
power resources and IUB resources can be saved

During the hard handover, the frequency of the original cell and target cell are the
same, so when the UE want to setup the RL with the target cell, the original cell will
cause DL interference to the UE.

Confidential Information of Huawei. No Spreading Without Permission

N-50

Course Name

Key parameters of Intra-frequency Hard handover


BEBITRATETHD

Parameter name: BE service handover rate threshold

The default value of this parameter is 384k

The Parameters about 1D Event

Time to trigger

Hysteresis

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page50

BEBITRATETHD


Parameter name: BE service handover rate threshold

Value range: 8k,

16k, 32k, 64k, 128k, 144k, 256k, 384k

Content: The bit rate threshold used to determine whether to perform


soft handover for the Best Effort (BE) service on DCH. When the
maximum bit rate of the BE service is lower than or equal to this
threshold, the system will perform soft handover for this user to
guarantee the service quality. If the maximum bit rate of the BE
service is higher than the threshold, the system will perform intrafrequency hard handover for this user to avoid the too great effect of
soft handover on the system capacity. .

The recommended value of this parameter is 384k.

Set this parameter through SET

HOCOMM, query it through SET HOCOMM.

Confidential Information of Huawei. No Spreading Without Permission

N-51

Course Name

Contents
3. The Basic Handovers
3.1 Soft Handover
3.2 Intra-frequency Hard Handover
3.3 Inter-frequency Hard Handover
3.4 Inter-RAT Hard Handover
3.5 Blind Handover

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page51

Confidential Information of Huawei. No Spreading Without Permission

N-52

Course Name

Brief Introduction of Inter-Frequency Handover




Characters of Soft Handover




The frequency of original cell and source cell are different

There is only one RL for the UE

The compressed mode is needed

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page52

If the frequency of the original cell and target cell are different, the soft handover is
impossible.

In a WCDMA FDD system, the UE in CELL_DCH state sends and receives signals
continuously in uplink and downlink channels. If the UE in this case needs to measure
the pilot signal strength of an inter-frequency WCDMA or GSM cell, and it has only
mono-frequency receiver, the UE must use the compressed mode technique.

Confidential Information of Huawei. No Spreading Without Permission

N-53

Course Name

Compressed Mode


Purpose


Measure the inter-frequency cell or Inter-RAT cell under FDD mode

Categories


Downlink compressed mode

Uplink compressed mode

Realization Methods


SF/2

Higher layer scheduling

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page53

In order to realize inter-frequency and inter-RAT measurement , WCDMA system


introduces compressed mode .

In DL, during compressed mode ,UE receiver can test signal from other frequency. In
order to avoid the effect cause by UE transmitter, compress mode is also used in UL.

The compressed mode includes two types, spreading factor reduction (SF/2) and high
layer approaches. The usage of type of compressed mode is decided by the RNC
automatically, according to spreading factor used in uplink or downlink.

Confidential Information of Huawei. No Spreading Without Permission

N-54

Course Name

Measurement of Inter-frequency Handover




Measurement quantity


CPICH RSCP

CPICH Ec/No

Reporting mode


Periodic reporting

Event trigger reporting

Event trigger reporting to Periodic reporting

Event type


2B,2C,2D,2F

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page54

Inter-frequency handover is also based on measurement. Similar with soft handover,


measurement quantity include CPICH RSCP or Ec/No

UE can report the measurement result when event triggered ,then RNC performs
handover decision. Or the UE periodically reports the inter-frequency measurement
report, and the RNC decides the handover after evaluation.

Confidential Information of Huawei. No Spreading Without Permission

N-55

Course Name

Inter-frequency Handover Measurement Events


Event
2D

Description
When the current signal quality is lower than the preset threshold , the
UTRAN enables the compressed mode and starts inter-frequency
measurement

2F

When the current signal quality is higher than the preset threshold, the
UTRAN disables the compressed mode and stops inter-frequency
measurement

2B

When the current signal frequency is lower than the preset threshold and
the signal quality of an inter-frequency neighbouring cell is higher than
the preset threshold , the UTRAN trigger an inter-frequency handover
based on coverage

2C

The estimated quality of a inter-frequency neighbor cell is higher than the


preset threshold

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page55

During the movement, UE can detect the severing cell signal is getting worse, then
the UE will report a 2D event to trigger compress mode, and then the UE can
measure the signals of inter-frequency neighbors. During the measurement period, if
the serving cell signal recovers, UE will report a 2F event to stop compress mode,
that is to stop the inter-frequency measurement.

During the compress mode ,UE can measure the inter-frequency cell signal, and 2B
and 2C event may be triggered.

Confidential Information of Huawei. No Spreading Without Permission

N-56

Course Name

The Trigger Algorithm of 2D Event

Event 2D is triggered on the basis of the following formula

QUsed TUsed 2d H2d / 2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page56

QUsed is the measured quality of the cell that uses the current frequency.
TUsed2d is the absolute quality threshold of the cell that uses the current
frequency. Based on the service type (CS or PS) and measurement quantity
(CPICH Ec/No or RSCP), this threshold can be configured as Inter-freq CS
measure start Ec/No THD, Inter-freq PS measure start Ec/No THD, Inter-freq
CS measure start RSCP THD, Inter-freq PS measure start RSCP THD
respectively.

H2d is the event 2D hysteresis value 2D hysteresis.


After the conditions of Event 2D are fulfilled and maintained until the 2D event
trigger delay time is reached, the UE reports the Event 2D measurement
report message.

Confidential Information of Huawei. No Spreading Without Permission

N-57

Course Name

Key parameters of of 2D Event


InterFreqCSThd2DEcN0

Parameter name: Inter-freq CS measure start Ec/No THD

The default value of this parameter is -14 dB

InterFreqPSThd2DEcN0

Parameter name: Inter-freq PS measure start Ec/No THD

The default value of this parameter is -14 dB

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page57

InterFreqCSThd2DEcN0

Parameter name: Inter-freq CS measure start Ec/No THD

Value range: -24~0dB;

Content: For CS domain services, when Ec/No is used as the measurement quantity
for inter-frequency measurement, the RNC sends the signaling to activate
compressed mode and start inter-frequency measurement, if the UE reports the event
2D when the measured value is smaller than the value of this parameter.

The recommended value of this parameter is -14dB

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

InterFreqPSThd2DEcN0

Parameter name: Inter-freq PS measure start Ec/No THD

Value range: -24~0dB;

Content: For

PS domain services, when Ec/No is used as the measurement quantity


for inter-frequency measurement, the RNC sends the signaling to activate
compressed mode and start inter-frequency measurement, if the UE reports the event
2D when the measured value is smaller than the value of this parameter.

The recommended value of this parameter is -14dB

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-58

Course Name

Key parameters of of 2D Event


InterFreqCSThd2DRSCP

Parameter name: Inter-freq CS measure start RSCP THD

The default value of this parameter is -95 dBm

InterFreqPSThd2DRSCP

Parameter name: Inter-freq PS measure start RSCP THD

The default value of this parameter is -95 dBm

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page58

InterFreqCSThd2DRSCP

Parameter name: Inter-freq CS measure start RSCP THD

Value range: -115~-25dBm;

Content: For CS domain services, when RSCP is used as the measurement quantity
for inter-frequency measurement, the RNC sends the signaling to activate
compressed mode and start inter-frequency measurement, if the UE reports the event
2D when the measured value is smaller than the value of this parameter.

The recommended value of this parameter is -95dB

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

InterFreqPSThd2DRSCP

Parameter name: Inter-freq PS measure start RSCP THD

Value range: -115~-25dBm;

Content: For

PS domain services, whenRSCP is used as the measurement quantity for


inter-frequency measurement, the RNC sends the signaling to activate compressed
mode and start inter-frequency measurement, if the UE reports the event 2D when the
measured value is smaller than the value of this parameter.


The recommended value of this parameter is -95dB

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-59

Course Name

Key parameters of 2D Event


HYSTFOR2D

Parameter name: 2D event hysteresis

The default value of this parameter is 4( 2dB )

TRIGTIME2D

Parameter name: 2D event trigger delay time

The default value of this parameter is D320 ( 320ms )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page59

HYSTFOR2D

Parameter name: 2D event hysteresis

Value range: 0

to 14.5 dB, step: 0.5

Content: The value of this parameter is relevant to the slow fading


characteristic. The larger the value of this parameter, the less the ping-pong
effect and the fewer the decision mistakes. In this case, however, the event
2D might not be triggered in time.

The recommended value of this parameter is 4 ( 2dB )

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

TRIGTIME2D

Parameter name: 2D event trigger delay time

Value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560,

5000 ms
Content: The value of this parameter is relevant to the slow fading
characteristic. The larger the value of this parameter, the lower the incorrect
decision probability, but the slower the response of the event 2D to
measurement signal change.

The recommended value of this parameter is D320 ( 320ms )

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-60

Course Name

The Trigger Algorithm of 2F Event




Event 2F is triggered on the basis of the following formula

QUsed TUsed 2 f + H 2 f / 2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page60

QUsed is the measured quality of the cell that uses the current frequency.
frequency.
TUsed2F is the absolute quality threshold of the cell that uses the current
current
frequency. Based on the service type (CS or PS) and measurement quantity
(CPICH Ec/No
Ec/No or RSCP), this threshold can be configured as InterInter-freq CS
measure start Ec/No
Ec/No THD, InterInter-freq PS measure start Ec/No
Ec/No THD, InterInter-freq
CS measure start RSCP THD, InterInter-freq PS measure start RSCP THD
respectively.

H2F is the event 2F hysteresis value 2F hysteresis.


hysteresis.
After the conditions of Event 2F are fulfilled and maintained until
until the 2F event
trigger delay time is reached, the UE reports the Event 2F measurement
measurement report
message.

Confidential Information of Huawei. No Spreading Without Permission

N-61

Course Name

Key parameters of 2F Event


InterFreqCSThd2FEcN0

Parameter name: Inter-freq CS measure stop Ec/No THD

The default value of this parameter is -12 dB

InterFreqPSThd2FEcN0

Parameter name: Inter-freq PS measure stop Ec/No THD

The default value of this parameter is -12 dB

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page61

InterFreqCSThd2FEcN0

Parameter name: Inter-freq CS measure stop Ec/No THD

Value range: -24~-0dB;

Content: For CS domain services, when Ec/No is used as the measurement quantity
for inter-frequency measurement, the RNC sends the signaling to deactivate
compressed mode and stop inter-frequency measurement, if the UE reports the event
2F when the measured value is larger than the value of this parameter. .

The recommended value of this parameter is -12dB

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

InterFreqPSThd2FEcN0

Parameter name: Inter-freq PS measure start Ec/No THD

Value range: -24~0dB;

Content: For

PS domain services, when Ec/No is used as the measurement quantity


for inter-frequency measurement, the RNC sends the signaling to deactivate
compressed mode and stop inter-frequency measurement, if the UE reports the event
2F when the measured value is larger than the value of this parameter.

The recommended value of this parameter is -12dB

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-62

Course Name

Key parameters of 2F Event


InterFreqCSThd2FRSCP

Parameter name: Inter-freq CS measure stop RSCP THD

The default value of this parameter is -92 dBm

InterFreqPSThd2FRSCP

Parameter name: Inter-freq PS measure stop RSCP THD

The default value of this parameter is -92 dBm

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page62

InterFreqCSThd2FRSCP

Parameter name: Inter-freq CS measure stop RSCP THD

Value range: -115~-25dBm;

Content: For CS domain services, when RSCP is used as the measurement quantity
for inter-frequency measurement, the RNC sends the signaling to deactivate
compressed mode and stop inter-frequency measurement, if the UE reports the event
2F when the measured value is larger than the value of this parameter. .

The recommended value of this parameter is -92dBm

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

InterFreqPSThd2FRSCP

Parameter name: Inter-freq PS measure start RSCP THD

Value range: -115~-25dB;

Content: For

PS domain services, when RSCP is used as the measurement quantity


for inter-frequency measurement, the RNC sends the signaling to deactivate
compressed mode and stop inter-frequency measurement, if the UE reports the event
2F when the measured value is larger than the value of this parameter.

The recommended value of this parameter is -92dB

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-63

Course Name

Key parameters of 2F Event


HYSTFOR2F

Parameter name: 2F event hysteresis

The default value of this parameter is 4( 2dB )

TRIGTIME2F

Parameter name: 2F event trigger delay time

The default value of this parameter is D1280 ( 1280ms )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page63

HYSTFOR2F

Parameter name: 2F event hysteresis

Value range: 0

to 14.5 dB, step: 0.5

Content: The value of this parameter is relevant to the slow fading


characteristic. The larger the value of this parameter, the less the ping-pong
effect and the fewer the decision mistakes. In this case, however, the event
2F might not be triggered in time.

The recommended value of this parameter is 4 ( 2dB )

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

TRIGTIME2F

Parameter name: 2F event trigger delay time

Value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560,

5000 ms
Content: The value of this parameter is relevant to the slow fading
characteristic. The larger the value of this parameter, the lower the incorrect
decision probability, but the slower the response of the event 2F to
measurement signal change.

The recommended value of this parameter is D1280 ( 1280ms )

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-64

Course Name

The Trigger Algorithm of 2B Event

Event 2B is triggered on the basis of the following formula

QNonused TNonused2b + H2b / 2

, and

QUsed TUsed 2b H2b / 2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page64

QNoused is the measured quality of the cell that uses other frequency.
TNoused2b is the absolute quality threshold of the cell that uses other frequency.
Based on the service type (CS or PS) and measurement quantity (CPICH
Ec/No or RSCP), this threshold can be configured as Inter-freq CS target
frequency trigger Ec/No THD, Inter-freq PS target frequency trigger Ec/No
THD, Inter-freq CS target frequency trigger RSCP THD, And Inter-freq PS
target frequency trigger RSCP THD respectively.

QUsed is the measured quality of the cell that uses the current frequency.
TUsed2d is the absolute quality threshold of the cell that uses the current
frequency. Based on the service type (CS or PS) and measurement quantity
(CPICH Ec/No or RSCP), this threshold can be configured as Inter-freq CS
measure start Ec/No THD, Inter-freq PS measure start Ec/No THD, Inter-freq
CS measure start RSCP THD, Inter-freq PS measure start RSCP THD
respectively.

H2b is the event 2B hysteresis value 2B hysteresis.

Confidential Information of Huawei. No Spreading Without Permission

N-65

Course Name

Key parameters of 2B Event


InterFreqCovHOCSThdEcN0

Parameter name: Inter-freq CS target frequency trigger Ec/No THD

The default value of this parameter is -12 dB

InterFreqCovHOPSThdEcN0

Parameter name: Inter-freq PS target frequency trigger Ec/No THD

The default value of this parameter is -12 dB

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page65

InterFreqCovHOCSThdEcN0

Parameter name: Inter-freq CS target frequency trigger Ec/No THD

Value range: -24~0dB;

Content: For CS domain services,


- If the value of [Inter-frequency measure report mode] is EVENT_TRIGGER, this
parameter is used to set the measurement control on the event 2B. The quality of the
target frequency being higher than this threshold is necessary to the triggering of the
event 2B.
- If the value of [Inter-frequency measure report mode] is PERIODICAL_REPORTING,
this parameter is used to evaluate inter-frequency handovers at the RNC.

The recommended value of this parameter is -12dB

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

InterFreqCovHOPSThdEcN0

Parameter name: Inter-freq PS target frequency trigger Ec/No THD

Value range: -24~0dB;

Content: - If the value of [Inter-frequency measure report mode] is EVENT_TRIGGER,


this parameter is used to set the measurement control on the event 2B. The quality of
the target frequency being higher than this threshold is necessary to the triggering of
the event 2B.
- If the value of [Inter-frequency measure report mode] is PERIODICAL_REPORTING,
this parameter is used to evaluate inter-frequency handovers at the RNC.

The recommended value of this parameter is -12dB

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-66

Course Name

Key parameters of 2B Event


InterFreqCovHOCSThdRSCP

Parameter name: Inter-freq CS target frequency trigger RSCP THD

The default value of this parameter is -92 dBm

InterFreqCovHOPSThdRSCP

Parameter name: Inter-freq PS target frequency trigger RSCP THD

The default value of this parameter is -92 dBm

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page66

InterFreqCovHOCSThdRSCP

Parameter name: Inter-freq CS target frequency trigger RSCP THD

Value range: -115~-25dBm;

Content: For CS domain services, when RSCP is used as the measurement quantity
for inter-frequency measurement, the RNC sends the signaling to activate
compressed mode and start inter-frequency measurement, if the UE reports the event
2D when the measured value is smaller than the value of this parameter.

The recommended value of this parameter is -95dB

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

InterFreqPSThd2DRSCP

Parameter name: Inter-freq PS measure start RSCP THD

Value range: -115~-25dBm;

Content: For

PS domain services, whenRSCP is used as the measurement quantity for


inter-frequency measurement, the RNC sends the signaling to activate compressed
mode and start inter-frequency measurement, if the UE reports the event 2D when the
measured value is smaller than the value of this parameter.


The recommended value of this parameter is -95dB

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-67

Course Name

Key parameters of 2B Event




IFHOUsedFreqCSThdEcN0


Parameter name: Inter-freq CS Used frequency trigger Ec/No THD

The default value of this parameter is -12dB

IFHOUsedFreqPSThdEcN0


Parameter name: Inter-freq PS Used frequency trigger Ec/No THD

The default value of this parameter is -12 dB

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page67

IFHOUsedFreqCSThdEcN0


Parameter name: Inter-freq CS Used frequency trigger Ec/No THD

Value range: -24~0

dB

Content: For CS domain services, if the value of [Inter-frequency measure


report mode] is EVENT_TRIGGER, this parameter is used to set the
measurement control on the event 2B. The quality of the used frequency
being lower than this threshold is necessary to the triggering of the event 2B .


The recommended value of this parameter is -12 dB

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

IFHOUsedFreqPSThdEcN0


Parameter name: Inter-freq PS Used frequency trigger Ec/No THD

Value range: -24~0 dB

Content: For PS domain services, if the value of [Inter-frequency measure


report mode] is EVENT_TRIGGER, this parameter is used to set the
measurement control on the event 2B. The quality of the used frequency
being lower than this threshold is necessary to the triggering of the event 2B .

The recommended value of this parameter is -12 dB

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-68

Course Name

Key parameters of 2B Event




IFHOUsedFreqCSThdRSCP


Parameter name: Inter-freq CS Used frequency trigger RSCP THD

The default value of this parameter is -92dBm

IFHOUsedFreqPSThdRSCP


Parameter name: Inter-freq PS Used frequency trigger RSCP THD

The default value of this parameter is -92 dBm

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page68

IFHOUsedFreqCSThdRSCP


Parameter name: Inter-freq CS Used frequency trigger RSCP THD

Value range: -115~-25

dBm

Content: For CS domain services, if the value of [Inter-frequency measure


report mode] is EVENT_TRIGGER, this parameter is used to set the
measurement control on the event 2B. The quality of the used frequency
being lower than this threshold is necessary to the triggering of the event 2B .


The recommended value of this parameter is -92 dBm

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

IFHOUsedFreqPSThdRSCP


Parameter name: Inter-freq PS Used frequency trigger RSCP THD

Value range: -115~-25 dBm

Content: For PS domain services, if the value of [Inter-frequency measure


report mode] is EVENT_TRIGGER, this parameter is used to set the
measurement control on the event 2B. The quality of the used frequency
being lower than this threshold is necessary to the triggering of the event 2B .

The recommended value of this parameter is -92 dBm

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-69

Course Name

Key parameters of 2B Event


HYSTFOR2B

Parameter name: 2B event hysteresis

The default value of this parameter is 4( 2dB )

TRIGTIME2B

Parameter name: 2B event trigger delay time

The default value of this parameter is D0 ( 0ms )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page69

HYSTFOR2B

Parameter name: 2B event hysteresis

Value range: 0

to 14.5 dB, step: 0.5

The value of this parameter is relevant to the slow fading characteristic. The
larger the value of this parameter, the less the ping-pong effect and the fewer
the decision mistakes. In this case, however, the event 2B might not be
triggered in time.

The recommended value of this parameter is 4 ( 2dB )

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

TRIGTIME2B

Parameter name: 2B event trigger delay time

Value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560,

5000 ms
Content: The value of this parameter is relevant to the slow fading
characteristic. The larger the value of this parameter, the lower the incorrect
decision probability, but the slower the response of the event 2B to
measurement signal change.

The recommended value of this parameter is D0 (0ms )

Set this parameter through SET

INTERFREQHOCOV, query it through LST

INTERFREQHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-70

Course Name

The Trigger Algorithm of 2C Event

Event 2C is triggered on the basis of the following formula

QNon used TNon used 2c + H 2c / 2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page70

QNoused is the measured quality of the cell that uses other frequency.
TNoused is the absolute quality threshold of the cell that uses other frequency.
Inter-freq measure target frequency trigger Ec/No THD.
H2c is the event 2C hysteresis value 2C hysteresis.

Confidential Information of Huawei. No Spreading Without Permission

N-71

Course Name

Key parameters of 2C Event




InterFreqNCovHOThdEcN0


Parameter name: Inter-freq CS target frequency trigger Ec/No THD

The default value of this parameter is -16 dB

Hystfor2C


Parameter name: 2C hysteresis

The default value of this parameter is 6 (3dB)

TrigTime2C


Parameter name: 2C event trigger delay time

The default value of this parameter is D640 (640ms)

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page71

InterFreqNCovHOThdEcN0


Parameter name: Inter-freq CS target frequency trigger Ec/No THD

Value range: -24~0dB;

Content: This parameter is used to set measurement control on the event 2C. The event 2C is
triggered when the signal quality of the target frequency is above this threshold .

The recommended value of this parameter is -16dB

Set this parameter through SET INTERFREQHONCOV, query it through LST


INTERFREQHONCOV.


Hystfor2C


Parameter name: 2C hysteresis

Value range: 0 to 14.5dB, step: 0.5 ;

Content: The event 2C is applied to non-coverage-based inter-frequency hard handover


scenarios where inter-frequency measurement needs to be started. The event 2C is reported
when the estimated quality of a non-used frequency is above a certain threshold. For details
about the event 2C, refer to the 3GPP TS 25.331. The value of this parameter is relevant to the
slow fading characteristic. The larger the value of this parameter, the less the ping-pong effect
and the fewer the decision mistakes. In this case, however, the event 2C might not be triggered
in time .

The recommended value of this parameter is 6 (3dB)

Set this parameter through SET INTERFREQHONCOV, query it through LST


INTERFREQHONCOV.


TrigTime2C


Parameter name: 2C event trigger delay time

Value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560, 5000 ms;

Content: The value of this parameter is relevant to the slow fading characteristic. The larger the
value of this parameter, the lower the incorrect decision probability, but the slower the response
of the event 2C to measurement signal change.

The recommended value of this parameter is D640 (640ms)

Set this parameter through SET INTERFREQHONCOV, query it through LST


INTERFREQHONCOV.


Confidential Information of Huawei. No Spreading Without Permission

N-72

Course Name

Contents
3. The Basic Handovers
3.1 Soft Handover
3.2 Intra-frequency Hard Handover
3.3 Inter-frequency Hard Handover
3.4 Inter-RAT Hard Handover
3.5 Blind Handover

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page72

Confidential Information of Huawei. No Spreading Without Permission

N-73

Course Name

Brief Introduction of Inter-RAT Handover




Characters of Inter-RAT Handover




Based on handover directions, inter-RAT handover is of two


types:


UMTS->GSM handover
UMTS->GSM coverage-based handover
UMTS->GSM load-based handover
UMTS->GSM service-based handover

GSM->UMTS handover

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page73

Inter-RAT handover refers to the handover between different systems, such as UMTS
and GSM, which use different radio access technologies (RAT).

Based on handover directions, inter-RAT handover is of two types:




UMTS->GSM handover (mainly described in this lecture)

GSM->UMTS handover

Based on triggering causes, UMTS->GSM handover includes:




UMTS->GSM coverage-based handover

The coverage of UMTS is discontinuous at the very beginning. On the


border, if the signal quality of UMTS rather than GSM is poor and if all
services of the UE are supported by GSM, UMTS->GSM coveragebased handover is triggered.
UMTS->GSM load-based handover

If the load of UMTS rather than GSM is heavy and all services of the
UE are supported by GSM, UMTS->GSM load-based handover is
triggered.
UMTS->GSM service-based handover

Based on layered services, traffic of different classes is handed over to


different systems. For example, when an Adaptive Multi Rate (AMR)
speech service is requested, this call could be handed over to GSM.

Confidential Information of Huawei. No Spreading Without Permission

N-74

Course Name

Brief Introduction of Inter-RAT Handover




Advantages


For coverage, it can solve the problems from one system to


another system

For capacity, it can enhance the utilizing efficiency of old


equipments(2G->3G)

Disadvantages


The flow is complicated, and it demands higher compatibility for


equipments

Demands more complicated UE

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page74

UMTS->GSM Handover Triggering Conditions




UMTS->GSM coverage-based handover

The CPICH Ec/N0 or CPICH RSCP of the UMTS cell to which the UE
connects is lower than the corresponding threshold. In addition, there is
a GSM cell whose GSM carrier RSSI is higher than the preset
threshold.
UMTS->GSM load-based handover

The load of the UMTS cell to which the UE connects is higher than the
threshold.
UMTS->GSM service-based handover

When a service is established, the Core Network (CN) requests a


handover of the service to GSM.

Confidential Information of Huawei. No Spreading Without Permission

N-75

Course Name

Measurement of Inter-RAT Handover




Measurement quantity


CPICH_Ec/N0

CPICH_RSCP

BOTH

Reporting mode


PERIODICAL_REPORTING

EVENT_TRIGGER

Event type


2D, 2F

3A, 3C

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page75

Measurement quantity


CPICH_Ec/N0 is valid when the InterInter-RAT measurement chooses


PERIODICAL_REPORTING Mode or EVENT_TRIGGER Mode.
CPICH_RSCP is valid when the InterInter-RAT measurement chooses
PERIODICAL_REPORTING Mode or EVENT_TRIGGER Mode.

BOTH is valid when the InterInter-RAT measurement chooses


PERIODICAL_REPORTING Mode.

Confidential Information of Huawei. No Spreading Without Permission

N-76

Course Name

Inter-RAT Handover Measurement Events


Event
2D

Description
When the signal quality of the currently used frequency is lower than the preset
threshold, the RNC enables the compressed mode and starts inter-RAT
measurement.

2F

When the signal quality of the currently used frequency is higher than the preset
threshold, the RNC disables the compressed mode and stops inter-RAT
measurement.

3A

When the signal quality of the currently used UMTS frequency is lower than the
preset threshold while the signal quality of any other system is higher than the
preset threshold, the RNC triggers UMTS->GSM handover based on coverage.

3C

When the signal quality of any other system is higher than the preset threshold,
the RNC triggers UMTS->GSM handover based on load or service.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

2D Event: initiate GSM measurement

2F Event: stop GSM measurement

3A Event: based on coverage

3C Event: based on non-coverage

Page76

Confidential Information of Huawei. No Spreading Without Permission

N-77

Course Name

The Trigger Algorithm of 2D Event




Event 2D is triggered on the basis of the following formula:

Q Used TUsed2d - H 2d / 2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page77

QUsed is the measurement value of the cell at the currently used frequency.

TUsed2d is the absolute quality threshold of the cell at the currently used frequency.
Based on CS or PS services, CPICH Ec/No, or RSCP measurement quantity, it can
be Inter-RAT CS measure start Ec/No THD, Inter-RAT PS measure start Ec/No THD,
Inter-RAT CS measure start RSCP THD, or Inter-RAT PS measure start RSCP THD.

H2d is 2D hysteresis, the hysteresis value of event 2D.

When the conditions for event 2D are met and maintained in time-to-trigger specified
in 2D event trigger delay time, the UE sends the measurement report of Event 2D.

Confidential Information of Huawei. No Spreading Without Permission

N-78

Course Name

Key Parameters of 2D Event




INTERRATCSTHD2DECNO


Parameter name: Inter-RAT CS measure start Ec/No THD

The default value of this parameter is -14 ( -14 dB )

INTERRATPSTHD2DECNO


Parameter name: Inter-RAT PS measure start Ec/No THD

The default value of this parameter is -15 ( -15 dB )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page78

INTERRATCSTHD2DECNO


Parameter name: Inter-RAT CS measure start Ec/No THD [dB]

Value range: -24~0

Physical unit: dB

Content: For CS domain services, when Ec/No is used as the measurement quantity for interRAT measurement, the RNC sends the signaling to activate compressed mode and start interRAT measurement, if the UE reports the event 2D when the measured value is smaller than the
value of this parameter.

The recommended value of this parameter is -14 ( -14 dB ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

INTERRATPSTHD2DECNO


Parameter name: Inter-RAT PS measure start Ec/No THD [dB]

Value range: -24~0

Physical unit: dB

Content: For PS domain services, when Ec/No is used as the measurement quantity for interRAT measurement, the RNC sends the signaling to activate compressed mode and start interRAT measurement, if the UE reports the event 2D when the measured value is smaller than the
value of this parameter.

The recommended value of this parameter is -15 ( -15 dB ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-79

Course Name

Key Parameters of 2D Event




INTERRATCSTHD2DRSCP


Parameter name: Inter-RAT CS measure start RSCP THD

The default value of this parameter is -100 ( -100 dBm )

INTERRATPSTHD2DRSCP


Parameter name: Inter-RAT PS measure start RSCP THD

The default value of this parameter is -110 (-110 dBm )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page79

INTERRATCSTHD2DRSCP


Parameter name: Inter-RAT CS measure start RSCP THD [dB]

Value range: -115~-25

Physical unit: dBm

Content: For CS domain services, when RSCP is used as the measurement quantity for interRAT measurement, the RNC sends the signaling to activate compressed mode and start interRAT measurement, if the UE reports the event 2D when the measured value is smaller than the
value of this parameter.

The recommended value of this parameter is -100 ( -100 dB ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

INTERRATPSTHD2DRSCP


Parameter name: Inter-RAT PS measure start RSCP THD [dB]

Value range: -115~-25

Physical unit: dBm

Content: For PS domain services, when RSCP is used as the measurement quantity for interRAT measurement, the RNC sends the signaling to activate compressed mode and start interRAT measurement, if the UE reports the event 2D when the measured value is smaller than the
value of this parameter.

The recommended value of this parameter is -110 ( -110 dB ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-80

Course Name

Key Parameters of 2D Event




HYSTFOR2D


Parameter name: 2D hysteresis

The default value of this parameter is 4 ( 2 dB )

TRIGTIME2D


Parameter name: 2D event trigger delay time

The default value of this parameter is D320 (320 ms )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

HYSTFOR2D


Parameter name: 2D hysteresis[0.5dB]

Value range: 0~29

Physical value range: 0~14.5, step: 0.5

Physical unit: dB

Page80

Content: The value of this parameter is relevant to the slow fading characteristic. The larger the
value of this parameter, the less the ping-pong effect and the fewer the decision mistakes. In
this case, however, the event 2D might not be triggered in time.

The recommended value of this parameter is 4 ( 2 dB ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

TRIGTIME2D






Parameter name: 2D event trigger delay time[ms]


Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640,
D1280, D2560, D5000
Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560,
5000
Physical unit: ms
Content: The value of this parameter is relevant to the slow fading characteristic. The larger the
value of this parameter, the lower the incorrect decision probability, but the slower the response
of the event 2D to measurement signal change.

The recommended value of this parameter is D320 ( 320ms ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-81

Course Name

The Trigger Algorithm of 2F Event




Event 2F is triggered on the basis of the following formula:

Q Used TUsed2f + H 2f / 2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page81

QUsed is the measurement value of the cell at the currently used frequency.

TUsed2f is the absolute quality threshold of the cell at the currently used frequency.
Based on CS or PS services, CPICH Ec/No, or RSCP measurement quantity, it can
be Inter-RAT CS measure start Ec/No THD, Inter-RAT PS measure start Ec/No THD,
Inter-RAT CS measure start RSCP THD, or Inter-RAT PS measure start RSCP THD.

H2f is 2F hysteresis, the hysteresis value of event 2F.

When the conditions for event 2F are met and maintained in time-to-trigger specified
in 2F event trigger delay time, the UE sends the measurement report of Event 2F.

Confidential Information of Huawei. No Spreading Without Permission

N-82

Course Name

Key Parameters of 2F Event




INTERRATCSTHD2FECNO


Parameter name: Inter-RAT CS measure stop Ec/No THD

The default value of this parameter is -12 ( -12 dB )

INTERRATPSTHD2FECNO


Parameter name: Inter-RAT PS measure stop Ec/No THD

The default value of this parameter is -13 ( -13 dB )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

INTERRATCSTHD2FECNO


Parameter name: Inter-RAT CS measure stop Ec/No THD [dB]

Value range: -24~0

Physical unit: dB

Page82

Content: For CS domain services, when Ec/No is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to deactivate compressed mode
and stop inter-RAT measurement, if the UE reports the event 2F when the measured
value is larger than the value of this parameter.

The recommended value of this parameter is -12 ( -12 dB ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

INTERRATPSTHD2FECNO


Parameter name: Inter-RAT PS measure stop Ec/No THD [dB]

Value range: -24~0

Physical unit: dB

Content: For PS domain services, when Ec/No is used as the measurement quantity for

inter-RAT measurement, the RNC sends the signaling to deactivate compressed mode
and stop inter-RAT measurement, if the UE reports the event 2F when the measured
value is larger than the value of this parameter.


The recommended value of this parameter is -13 ( -13 dB ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-83

Course Name

Key Parameters of 2F Event




INTERRATCSTHD2FRSCP


Parameter name: Inter-RAT CS measure stop RSCP THD

The default value of this parameter is -97 ( -97 dBm )

INTERRATPSTHD2FRSCP


Parameter name: Inter-RAT PS measure stop RSCP THD

The default value of this parameter is -107 (-107 dBm )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page83

INTERRATCSTHD2FRSCP


Parameter name: Inter-RAT CS measure stop RSCP THD [dBm]

Value range: -115~-25

Physical unit: dBm

Content: For CS domain services, when RSCP is used as the measurement quantity for

inter-RAT measurement, the RNC sends the signaling to deactivate compressed mode
and stop inter-RAT measurement, if the UE reports the event 2F when the measured
value is larger than the value of this parameter.

The recommended value of this parameter is -97 ( -97 dBm ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

INTERRATPSTHD2FRSCP


Parameter name: Inter-RAT PS measure stop RSCP THD [dBm]

Value range: -115~-25

Physical unit: dBm

Content: For PS domain services, when RSCP is used as the measurement quantity for
inter-RAT measurement, the RNC sends the signaling to deactivate compressed mode
and stop inter-RAT measurement, if the UE reports the event 2F when the measured
value is larger than the value of this parameter.

The recommended value of this parameter is -107 ( -107 dBm ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-84

Course Name

Key Parameters of 2F Event




HYSTFOR2F


Parameter name: 2F hysteresis

The default value of this parameter is 4 ( 2 dB )

TRIGTIME2F


Parameter name: 2F event trigger delay time

The default value of this parameter is D1280 (1280 ms )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

HYSTFOR2F


Parameter name: 2F hysteresis[0.5dB]

Value range: 0~29

Physical value range: 0~14.5, step: 0.5

Physical unit: dB

Page84

Content: The value of this parameter is relevant to the slow fading characteristic. The larger the
value of this parameter, the less the ping-pong effect and the fewer the decision mistakes. In
this case, however, the event 2F might not be triggered in time.

The recommended value of this parameter is 4 ( 2 dB ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

TRIGTIME2F






Parameter name: 2F event trigger delay time[ms]


Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640,
D1280, D2560, D5000
Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560,
5000
Physical unit: ms
Content: The value of this parameter is relevant to the slow fading characteristic. The larger the
value of this parameter, the lower the incorrect decision probability, but the slower the response
of the event 2F to measurement signal change.

The recommended value of this parameter is D1280 ( 1280ms ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-85

Course Name

The Trigger Algorithm of 3A Event




Event 3A is triggered on the basis of the following formula:

Q Used TUsed3a + H 3a / 2
M OtherRat + CIOOtherRat TOtherRat + H 3a / 2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page85

QUsed is the measurement value of the cell at the currently used frequency.

TUsed is the absolute quality threshold of the cell at the currently used frequency.
Based on CS or PS services, CPICH Ec/No, or RSCP measurement quantity, it can
be Inter-RAT CS Used frequency trigger Ec/No THD, Inter-RAT PS Used frequency
trigger Ec/No THD, Inter-RAT CS Used frequency trigger RSCP THD, or Inter-RAT
PS Used frequency trigger RSCP THD.

MOtherRat is the measurement value of the cell (in another RAT) in the reporting range.

CIOOtherRat is cell individual offset, the offset value of the cell (in another RAT) in the
reporting range.

TOtherRat is the absolute inter-RAT handover threshold. Based on CS or PS services, it


can be Inter-RAT CS handover decision THD or Inter-RAT PS handover decision
THD.

H3a is 3A hysteresis, the hysteresis value of event 3A.

When the conditions for event 3A are met and maintained in time-to-trigger specified
in 3A event trigger delay time, the UE sends the measurement report of event 3A.

Confidential Information of Huawei. No Spreading Without Permission

N-86

Course Name

Key Parameters of 3A Event




IRHOUSEDFREQCSTHDECNO


Parameter name: Inter-RAT CS Used frequency trigger Ec/No


THD

The default value of this parameter is -12 ( -12 dB )

IRHOUSEDFREQPSTHDECNO


Parameter name: Inter-RAT PS Used frequency trigger Ec/No


THD

The default value of this parameter is -13 ( -13 dB )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

IRHOUSEDFREQCSTHDECNO


Parameter name: Inter-RAT CS Used frequency trigger Ec/No THD [dB]

Value range: -24~0

Physical unit: dB

Page86

Content: For CS domain services, when Ec/No is used as the measurement quantity for
inter-RAT measurement and the value of [Inter-RAT report mode] is
EVENT_TRIGGER, this parameter is used to set measurement control on the event
3A. The event 3A is triggered, when the quality of the currently used UTRAN frequency
is below this threshold and the [Inter-RAT CS handover decision THD] is reached.

The recommended value of this parameter is -12 ( -12 dB ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

IRHOUSEDFREQPSTHDECNO


Parameter name: Inter-RAT PS Used frequency trigger Ec/No THD [dB]

Value range: -24~0

Physical unit: dB

Content: For PS domain services, when Ec/No is used as the measurement quantity for

inter-RAT measurement and the value of [Inter-RAT report mode] is


EVENT_TRIGGER, this parameter is used to set measurement control on the event
3A. The event 3A is triggered, when the quality of the currently used UTRAN frequency
is below this threshold and the [Inter-RAT PS handover decision THD] is reached.


The recommended value of this parameter is -13 ( -13 dB ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-87

Course Name

Key Parameters of 3A Event




IRHOUSEDFREQCSTHDRSCP


Parameter name: Inter-RAT CS Used frequency trigger RSCP


THD

The default value of this parameter is -97 ( -97 dBm )

IRHOUSEDFREQCSTHDRSCP


Parameter name: Inter-RAT PS Used frequency trigger RSCP


THD

The default value of this parameter is -107 (-107 dBm )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page87

IRHOUSEDFREQCSTHDRSCP


Parameter name: Inter-RAT CS Used frequency trigger RSCP THD [dBm]

Value range: -115~-25

Physical unit: dBm

Content: For CS domain services, when RSCP is used as the measurement quantity for

inter-RAT measurement and the value of [Inter-RAT report mode] is


EVENT_TRIGGER, this parameter is used to set measurement control on the event
3A. The event 3A is triggered, when the quality of the currently used UTRAN frequency
is below this threshold and the [Inter-RAT CS handover decision THD] is reached.

The recommended value of this parameter is -97 ( -97 dBm ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

IRHOUSEDFREQCSTHDRSCP


Parameter name: Inter-RAT PS Used frequency trigger RSCP THD [dBm]

Value range: -115~-25

Physical unit: dBm

Content: For PS domain services, when RSCP is used as the measurement quantity for
inter-RAT measurement and the value of [Inter-RAT report mode] is
EVENT_TRIGGER, this parameter is used to set measurement control on the event
3A. The event 3A is triggered, when the quality of the currently used UTRAN frequency
is below this threshold and the [Inter-RAT PS handover decision THD] is reached.

The recommended value of this parameter is -107 ( -107 dBm ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-88

Course Name

Key Parameters of 3A Event




INTERRATCOVHOCSTHD


Parameter name: Inter-RAT CS handover decision THD

The default value of this parameter is 16 ( -95 dBm )

INTERRATCOVHOPSTHD


Parameter name: Inter-RAT PS handover decision THD

The default value of this parameter is 16 ( -95 dBm )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page88

INTERRATCOVHOCSTHD

Parameter name: Inter-RAT CS handover decision THD [dBm]

Value range: 0~63

Physical value range: -110~-48 (The value 1 corresponds to the physical value -110, 2 to 109, ..., 63 to -48.)

Physical unit: dBm

Content: For CS domain services,
- If the value of [Inter-RAT report mode] is EVENT_TRIGGER, this parameter is used to set the
measurement control on the event 3A. The event 3A is triggered, when the quality of the cell
with the target frequency is higher than this threshold and the threshold of the used frequency
quality of the corresponding measurement quantity is reached.
- If the value of [Inter-RAT report mode] is PERIODICAL_REPORTING, this parameter is used
to evaluate coverage-based inter-RAT handovers at the RNC.
Note that the value 0 means the physical value is smaller than -110 dBm.

The recommended value of this parameter is 16 ( -95 dBm ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.
INTERRATCOVHOPSTHD

Parameter name: Inter-RAT PS handover decision THD [dBm]

Value range: 0~63

Physical value range: -110~-48 (The value 1 corresponds to the physical value -110, 2 to 109, ..., 63 to -48.)

Physical unit: dBm

Content: For PS domain services,
- If the value of [Inter-RAT report mode] is EVENT_TRIGGER, this parameter is used to set the
measurement control on the event 3A. The event 3A is triggered, when the quality of the cell
with the target frequency is higher than this threshold and the threshold of the used frequency
quality of the corresponding measurement quantity is reached.
- If the value of [Inter-RAT report mode] is PERIODICAL_REPORTING, this parameter is used
to evaluate coverage-based inter-RAT handovers at the RNC.
Note that the value 0 means the physical value is smaller than -110 dBm.

The recommended value of this parameter is 16 (-95 dBm ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-89

Course Name

Key Parameters of 3A Event




HYSTFOR3A


Parameter name: 3A hysteresis

The default value of this parameter is 4 ( 2 dB )

TRIGTIME3A


Parameter name: 3A event trigger delay time

The default value of this parameter is D0 ( 0 ms )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

HYSTFOR3A


Parameter name: 3A hysteresis[0.5dB]

Value range: 0~15

Physical value range: 0~7.5, step: 0.5

Physical unit: dB

Page89

Content: The value of this parameter is relevant to the slow fading characteristic. The larger the
value of this parameter, the less the ping-pong effect and the fewer the decision mistakes. In
this case, however, the event 3A might not be triggered in time.

The recommended value of this parameter is 4 ( 2 dB ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

TRIGTIME3A






Parameter name: 3A event trigger delay time[ms]


Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640,
D1280, D2560, D5000
Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560,
5000
Physical unit: ms
Content: The value of this parameter is relevant to the slow fading characteristic. The larger the
value of this parameter, the lower the incorrect decision probability, but the slower the response
of the event 3A to measurement signal change.

The recommended value of this parameter is D0 ( 0ms ).

Set this parameter through SET INTERRATHOCOV, query it through LST INTERRATHOCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-90

Course Name

Key Parameters of 3A Event




CELLINDIVIDALOFFSET


Parameter name: Cell individual offset

The default value of this parameter is 0 ( 0 dB )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page90

CELLINDIVIDALOFFSET


Parameter name: Cell individual offset [dB]

Value range: -50~50

Physical unit: dB

Content: This parameter is used in inter-RAT handover decision. The larger the parameter, the
higher the handover priority of the GSM cell. The smaller the parameter, the lower the handover
priority of the GSM cell.

The recommended value of this parameter is 0 ( 0 dB ).

Set this parameter through ADD GSMNCELL, query it through LST GSMNCELL.

Confidential Information of Huawei. No Spreading Without Permission

N-91

Course Name

The Trigger Algorithm of 3C Event




Event 3C is triggered on the basis of the following formula:

M OtherRat + CIOOtherRat TOtherRat + H 3c / 2

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page91

MOtherRat is the measurement value of the cell (in another RAT) in the reporting range.

CIOOtherRat is cell individual offset, the offset value of the cell (in another RAT) in the
reporting range.

TOtherRat is the absolute inter-RAT handover threshold. Based on CS or PS services, it


can be Inter-RAT CS handover decision THD or Inter-RAT PS handover decision
THD.

H3c is 3C hysteresis, the hysteresis value of event 3C.

When the conditions for event 3C are met and the delay requirement specified by the
3C event trigger delay time parameter can be satisfied, the UE sends the
measurement report of event 3C.

Confidential Information of Huawei. No Spreading Without Permission

N-92

Course Name

Key Parameters of 3C Event




INTERRATNCOVHOCSTHD


Parameter name: Inter-RAT CS handover decision THD

The default value of this parameter is 21 ( -90 dBm )

INTERRATNCOVHOPSTHD


Parameter name: Inter-RAT PS handover decision THD

The default value of this parameter is 21 ( 21 dB )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

INTERRATNCOVHOCSTHD


Parameter name: Inter-RAT CS handover decision THD [dBm]

Value range: 0 to 63

Page92

Physical value range: -110 to -48 (The value 1 corresponds to the physical value -110, 2 to 109, ..., 63 to -48)
Physical unit: dB
Content: This parameter is used to set measurement control on the event 3C. The event 3C is
triggered when the quality of the target frequency is higher than this threshold. Note that the
value 0 means the physical value is smaller than -110 dBm.

The recommended value of this parameter is 21 ( -90 dBm ).

Set this parameter through SET INTERRATHONCOV, query it through LST INTERRATHONCOV.

INTERRATNCOVHOPSTHD


Parameter name: Inter-RAT PS handover decision THD [dBm]

Value range: 0 to 63

Physical value range: -110 to -48 (The value 1 corresponds to the physical value -110, 2 to 109, ..., 63 to -48)
Physical unit: dB
Content: The event 3C is triggered when the quality of the target frequency is higher than this
threshold. Note that the value 0 means the physical value is smaller than -110 dBm.

The recommended value of this parameter is 21 ( -90 dBm ).

Set this parameter through SET INTERRATHONCOV, query it through LST INTERRATHONCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-93

Course Name

Key Parameters of 3C Event




HYSTFOR3C


Parameter name: 3C hysteresis

The default value of this parameter is 0 ( 0 dB )

TRIGTIME3C


Parameter name: 3C event trigger delay time

The default value of this parameter is D640 ( 650 ms )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

HYSTFOR3C


Parameter name: 3C hysteresis[0.5dB]

Value range: 0~15

Physical value range: 0~7.5, step: 0.5

Physical unit: dB

Page93

Content: The value of this parameter is relevant to the slow fading characteristic. The larger the
value of this parameter, the less the ping-pong effect and the fewer decision mistakes. In this
case, however, the event 3C might not be triggered in time.

The recommended value of this parameter is 0 ( 0 dB ).

Set this parameter through SET INTERRATHONCOV, query it through LST INTERRATHONCOV.

TRIGTIME3C






Parameter name: 3C event trigger delay time[ms]


Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320, D640,
D1280, D2560, D5000
Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280, 2560,
5000
Physical unit: ms
Content: The value of this parameter is relevant to the slow fading characteristic. The larger the
value of this parameter, the lower the incorrect decision probability, but the slower the response
of the event 3C to measurement signal change.

The recommended value of this parameter is D640 ( 640ms ).

Set this parameter through SET INTERRATHONCOV, query it through LST INTERRATHONCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-94

Course Name

Key Parameters of 3C Event




PENALTYTIMEFORINTERRATHO


Parameter name: Inter-RAT handover failure penalty timer


length

The default value of this parameter is 30 ( 30 s )

INTERRATHOATTEMPTS


Parameter name: Inter-RAT handover max attempt times

The default value of this parameter is 16

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

PENALTYTIMEFORINTERRATHO


Parameter name: Inter-RAT handover failure penalty timer length [s]

Value range: 0 to 65535

Physical unit: s

Page94

Content: An inter-RAT handover to a GSM cell may fail due to the heavy load of the GSM cell.
Therefore, in the period of time specified by this parameter, inter-RAT handover requests are
not sent to the GSM cell.

The recommended value of this parameter is 30 ( 30 s ).

Set this parameter through SET INTERRATHONCOV, query it through LST INTERRATHONCOV.

INTERRATHOATTEMPTS


Parameter name: Inter-RAT handover max attempt times

Value range: 1 to 16

Physical unit: times

Content: This parameter specifies the maximum number of attempts for the RNC to perform
inter-RAT handovers after a non-coverage-based inter-RAT handover failure. For later
handover attempts, target cells must be selected. Ensure that the target cells have not been
tried but satisfy the handover conditions. No matter the inter-RAT handover failure penalty timer
expires or not.

The recommended value of this parameter is 16.

Set this parameter through SET INTERRATHONCOV, query it through LST INTERRATHONCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-95

Course Name

Key Parameters of 3C Event




INTERRATMEASTIME


Parameter name: Inter-RAT measure timer length [s]

The default value of this parameter is 60 ( 60 s )

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page95

INTERRATMEASTIME


Parameter name: Inter-RAT measure timer length [s]

Value range: 0 to 512

Physical unit: s

Content: After inter-RAT measurement starts, if no inter-RAT handover is performed when this
timer expires, the inter-RAT measurement is stopped. In addition, the compressed mode is
deactivated, if any. The value 0 indicates the timer is not to be enabled.

The recommended value of this parameter is 60 ( 60 S ).

Set this parameter through SET INTERRATHONCOV, query it through LST INTERRATHONCOV.

Confidential Information of Huawei. No Spreading Without Permission

N-96

Course Name

Contents
3. The Basic Handovers
3.1 Soft Handover
3.2 Intra-frequency Hard Handover
3.3 Inter-frequency Hard Handover
3.4 Inter-RAT Hard Handover
3.5 Blind Handover

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page96

Confidential Information of Huawei. No Spreading Without Permission

N-97

Course Name

Blind Handover Measurement




Blind handover means UE can directly handover to the


neighboring cell without measuring it.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page97

If the serving frequency signal is getting worse quickly, but UE can not trigger a interfrequency measurement and hard handover in time, blind handover might be used to
save the call.

In Huawei implementation, blind handover can be triggered by intra-frequency


measurement event 1F.

Confidential Information of Huawei. No Spreading Without Permission

N-98

Course Name

The Trigger Algorithm of 1F Event

10 LogMOld T1 f H1 f / 2


Where:


MOld is the measurement value of the cell signal that becomes


worse

T1f is the absolute threshold of event 1F.

H1f is the hysteresis value of event 1F.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page98

For different intra-frequency measurement quantity, the threshold T1f are set to 1F
Event Absolute EcNo Threshold, 1F Event Absolute RSCP Threshold respectively.

Confidential Information of Huawei. No Spreading Without Permission

N-99

Course Name

The Trigger Algorithm of 1F Event


Measurement
Quantity

Cell 1
1F Trigger
Delay Time
Absolute
Threshold T1f

Hysteresis
H1f /2

Time
Reporting
event 1F

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page99

If the signal quality of a cell in the active set is worse than T1f - H1f /2 , and last for a
certain time 1F Event Trigger Delay Time, then UE reports event 1F.

Confidential Information of Huawei. No Spreading Without Permission

N-100

Course Name

Key Parameters of Event 1F


INTRAABLTHDFOR1FECNO

Parameter name: 1F event absolute EcNo threshold

The recommended value is -24 dB

INTRAABLTHDFOR1FRSCP

Parameter name: 1F event absolute RSCP threshold

The recommended value is -115 dBm

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

INTRAABLTHDFOR1FECNO


Parameter name: 1F event absolute EcNo threshold

Value range: -24 to 0

Physical value range: -24 to 0 dB. Step: 1

Page100

Content: The absolute EcNo threshold of the event 1F.It is easier to trigger event 1F if
the value increases. It is harder to trigger event 1F if the value decreases.
Recommended value: -24

INTRAABLTHDFOR1FRSCP


Parameter name: 1F event absolute RSCP threshold

Value range: -115 to 25

Physical value range: -115 to 25 dB. Step: 1

Content: The absolute RSCP threshold of the event 1F.It is easier to trigger event 1F if
the value increases. It is harder to trigger event 1F if the value decreases.
The recommended value is -115 dBm

For RNC level, set these two parameter through SET INTRAFREQHO, query them
through LST INTRAFREQHO, and modify them through SET INTRAFREQHO
For cell level, set these two parameter through ADD CELLINTRAFREQHO, query them
through LST CELLINTRAFREQHO, and modify them through MOD
CELLINTRAFREQHO.

Confidential Information of Huawei. No Spreading Without Permission

N-101

Course Name

Key Parameters of Event 1F


HYSTFOR1F

Parameter name: 1F hysteresis

The recommended value is 8, namely 4 dB

TRIGTIME1F

Parameter name: 1F event trigger delay time

The recommended value is D640, namely 640 ms

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

HYSTFOR1F


Parameter name: 1F hysteresis

Value range: 0 to 15

Physical value range: 0 to 7.5 dB. Step: 0.5




Page101

Content: The hysteresis value of the event 1F. This parameter value is related to the
slow fading characteristic. The greater this parameter is set, the less ping-pong effect
and misjudgement can be caused. However, in this case, the event cannot be triggered
in time.
Recommended value: 8

TRIGTIME1F






Parameter name: 1F event trigger delay time


Value range: D0, D10, D20, D40, D60, D80, D100, D120, D160, D200, D240, D320,
D640, D1280, D2560, D5000
Physical value range: 0, 10, 20, 40, 60, 80, 100, 120, 160, 200, 240, 320, 640, 1280,
2560, 5000 ms
Content: The trigger delay time of the event 1F. This parameter value is related to the
slow fading characteristic. The greater this parameter is set, the smaller the
misjudgement probability, but the lower the response speed of the event to the
measured signal changes.
Recommended value: D640
For RNC level, set these two parameter through SET INTRAFREQHO, query them
through LST INTRAFREQHO, and modify them through SET INTRAFREQHO
For cell level, set these two parameter through ADD CELLINTRAFREQHO, query them
through LST CELLINTRAFREQHO, and modify them through MOD
CELLINTRAFREQHO.

Confidential Information of Huawei. No Spreading Without Permission

N-102

Course Name

Blind Handover Decision




After receiving event 1F of best cell from UE, the RNC


would check if blind handover neighbor is configured for the
cell.

If multiple blind handover neighbors are configured, the


RNC would perform blind handover to the target cell with
the highest priority

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

Page102

When we configure the inter-frequency neighbor cell or GSM neighbor cell, two
parameters of blind handover is included: Blind Handover Flag and Blind Handover
Priority.

Confidential Information of Huawei. No Spreading Without Permission

N-103

Course Name

Key Parameters of Blind Handover


BLINDHOFLAG

Parameter name: Blind handover flag

The default value is FALSE

BLINDHOPRIO

Parameter name: Blind handover Priority

The value is set according to actual situation.

Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

BLINDHOFLAG


Parameter name: Blind handover flag

Value range: FALSE, TRUE

Page103

Content: This parameter indicates whether the neighboring cell is the target cell for
blind handovers. If the value is TRUE, blind handovers can be performed to the
neighboring cell.
Default value: FALSE

BLINDHOPRIO


Parameter name: Blind handover Priority

Value range: 0 to 30

Content: The value 0 indicates the highest priority, and 30 the lowest. A neighboring
cell of a cell must have a unique priority.
It is suggested 0 to 15 assigned to the neighboring cells superposed to the cell
specified by [CELLID]. The success rate of handovers to these cells can be guaranteed.
Neighboring cells with priorities from 16 to 30 can be performed with blind handovers,
but the handovers may fail.

Recommended value (default value): none

Set these two parameter through ADD INTERFREQNCELL or ADD GSMNCELL, query
them through LST INTERFREQNCELL or LST GSMNCELL, and modify them through
MOD INTERFREQNCELL or MOD GSMNCELL.

Confidential Information of Huawei. No Spreading Without Permission

N-104

Course Name

Thank you
www.huawei.com

Confidential Information of Huawei. No Spreading Without Permission