Shellside Incremental Monitor

This monitor prints local shellside heat transfer and pressure drop parameters crosspass by
crosspass.
Because increments can number in the thousands, according to the exchanger's geometry, all
incremental values in a given crosspass are averaged to provide a manageable number of points.
Shell styles such as TEMA G, H, and J with multiple flow paths print a set of values for each flow path.
The first and last points of each flow path contain inlet/outlet conditions external to the exchanger.
Pressure drops for these points represent nozzle pressure drops.
NOTE: The values in this monitor are averaged across all the increments in each baffle space.
Often this averaging hides trends in the results and/or presents values that are correct
but appear wrong or misleading. If any of the information on the monitor appears
incorrect, check the information in the 3D plot.