You are on page 1of 7

Pipe - 8

VAN OR MINI VAN,


SHORTENED TO FIT
IF NECESSARY

CHAIR
COUCH

CHAIR
CHAIR

+0"

LAWN CHAIR
VO
M
(Q RAM
UIT
E S P DO
TE WN
EP
)

FIRE PIT

-44"

VECTORWORKS EDUCATIONAL VERSION

SHELVING UNIT

Pipe - 7
CAR COMPONENT

Pipe - 6

Pipe - 5

Pipe - 4

Pipe - 3

Pipe - 2

Pipe - 1

OPENI
NG
+8'-6"

DRAFTED BY: ACH

Pipe - 9

708-408-5957

Pipe - 10

DATE: 12/15/14

SCALE: 1/4" = 1'-0"

Pipe - 11

THIS DRAWING REPRESENTS VISUAL CONCEPTS AND


CONSTRUCTION SUGGESTIONS ONLY. IT DOES NOT REPLACE
THE KNOWLEDGE AND ADVICE OF A LICENSED STRUCTURAL
ENGINEER. THE DESIGNER IS UNQUALIFIED TO DETERMINE
THE STRUCTURAL APPROPRIATENESS OF THIS DESIGN AND
WILL NOT ASSUME RESPONSIBILITY FOR IMPROPER
ENGINEERING, HANDLING, OR USE. ALL MATERIALS AND
TECHNIQUES USED IN THE CONSTRUCTION OF THESE ITEMS
MUST CONFORM TO THE STRICTEST OF ALL STATE AND LOCAL
FIRE AND BUILDING CODES.

Pipe - 12

OF 5

Pipe - 13

CONVERTIBLE,
SHORTENED TO FIT
IF NECESSARY

GROUNDPLAN
ACT 1

TOOL CHEST

AHEALY87@GMAIL.COM

Pipe - 14

TECHNICAL DIR.: CHRIS BORRESON

Pipe - 15

SCENIC DESIGNER: ANDRA HEALY

DRESSING AREA

DIRECTOR: JACK REULER

DRESSING AREA

PLATE #

Pipe - 16

MR. BURNS

Pipe - 17

MANDELL WEISS
FORUM THEATRE

CL

UNIVERSITY OF CALIFORNIA SAN DIEGO

VECTORWORKS EDUCATIONAL VERSION

Pipe - 8

VAN OR MINI VAN,


SHORTENED TO FIT
IF NECESSARY

Pipe - 7

Pipe - 6

Pipe - 5

Pipe - 4

Pipe - 3

Pipe - 2
SHELVING UNIT

CAR COMPONENT

CHAIR
TABLE
TOOL CHEST

CHAIR

OPENI
NG
+8'-6"

FLOOR LAMP

ARMCHAIR

+0"
VO
M
(Q RAM
UIT
E S P DO
TE WN
EP
)

-44"

VECTORWORKS EDUCATIONAL VERSION

DRAFTED BY: ACH

Pipe - 9

708-408-5957

Pipe - 10

DATE: 12/15/14

SCALE: 1/4" = 1'-0"

Pipe - 11

THIS DRAWING REPRESENTS VISUAL CONCEPTS AND


CONSTRUCTION SUGGESTIONS ONLY. IT DOES NOT REPLACE
THE KNOWLEDGE AND ADVICE OF A LICENSED STRUCTURAL
ENGINEER. THE DESIGNER IS UNQUALIFIED TO DETERMINE
THE STRUCTURAL APPROPRIATENESS OF THIS DESIGN AND
WILL NOT ASSUME RESPONSIBILITY FOR IMPROPER
ENGINEERING, HANDLING, OR USE. ALL MATERIALS AND
TECHNIQUES USED IN THE CONSTRUCTION OF THESE ITEMS
MUST CONFORM TO THE STRICTEST OF ALL STATE AND LOCAL
FIRE AND BUILDING CODES.

Pipe - 12

OF 5

Pipe - 13

CONVERTIBLE,
SHORTENED TO FIT
IF NECESSARY

GROUNDPLAN
ACT 2

Pipe - 14

AHEALY87@GMAIL.COM

TOOL CHEST

TECHNICAL DIR.: CHRIS BORRESON

Pipe - 15

SHELVING UNIT

SCENIC DESIGNER: ANDRA HEALY

DRESSING AREA

DIRECTOR: JACK REULER

Pipe - 1

DRESSING AREA

PLATE #

Pipe - 16

MR. BURNS

Pipe - 17

MANDELL WEISS
FORUM THEATRE

CL

UNIVERSITY OF CALIFORNIA SAN DIEGO

VECTORWORKS EDUCATIONAL VERSION

Pipe - 8

Pipe - 7

CONVERTIBLE,
SHORTENED TO FIT
IF NECESSARY

+0"

SLIDE INTO VOM

SHELVING UNIT

CAR COMPONENT

Pipe - 6

Pipe - 5

Pipe - 4

Pipe - 3

Pipe - 2

Pipe - 1
VAN OR MINI VAN,
SHORTENED TO FIT
IF NECESSARY

TIRES, PIPES, AND CABLES


TO MAKE "BOAT RAILING"

OPENI
NG
+8'-6"

BIKE CONTRAPTION

VO
M
(Q RAM
UIT
E S P DO
TE WN
EP
)

-44"

VECTORWORKS EDUCATIONAL VERSION

DRAFTED BY: ACH

Pipe - 9

708-408-5957

Pipe - 10

DATE: 12/15/14

SCALE: 1/4" = 1'-0"

Pipe - 11

OF 5

Pipe - 12

THIS DRAWING REPRESENTS VISUAL CONCEPTS AND


CONSTRUCTION SUGGESTIONS ONLY. IT DOES NOT REPLACE
THE KNOWLEDGE AND ADVICE OF A LICENSED STRUCTURAL
ENGINEER. THE DESIGNER IS UNQUALIFIED TO DETERMINE
THE STRUCTURAL APPROPRIATENESS OF THIS DESIGN AND
WILL NOT ASSUME RESPONSIBILITY FOR IMPROPER
ENGINEERING, HANDLING, OR USE. ALL MATERIALS AND
TECHNIQUES USED IN THE CONSTRUCTION OF THESE ITEMS
MUST CONFORM TO THE STRICTEST OF ALL STATE AND LOCAL
FIRE AND BUILDING CODES.

Pipe - 13

GROUNDPLAN
ACT 3

TOOL CHEST

AHEALY87@GMAIL.COM

Pipe - 14

TECHNICAL DIR.: CHRIS BORRESON

Pipe - 15

SCENIC DESIGNER: ANDRA HEALY

DRESSING AREA

DIRECTOR: JACK REULER

DRESSING AREA

PLATE #

Pipe - 16

MR. BURNS

Pipe - 17

MANDELL WEISS
FORUM THEATRE

CL

UNIVERSITY OF CALIFORNIA SAN DIEGO

VECTORWORKS EDUCATIONAL VERSION

JUNKYARD ART FIGUREHEAD

VECTORWORKS EDUCATIONAL VERSION


PLATE #

OF 5

MR. BURNS
SECTION

DIRECTOR: JACK REULER

BLACK TRAVELER OR SCRIM


AS FAR DS AS POSSIBLE.

LEGS

DATE: 12/15/14

DRAFTED BY: ACH

708-408-5957

AHEALY87@GMAIL.COM

SCENIC DESIGNER: ANDRA HEALY

SCALE: 1/4" = 1'-0"

TECHNICAL DIR.: CHRIS BORRESON

UNIVERSITY OF CALIFORNIA SAN DIEGO

CATWALK 7

CATWALK 6

CATWALK 5

CATWALK 4

CATWALK 3

CATWALK 2

CATWALK 1

PIPE 1

PIPE 2

PIPE 3

PIPE 4

PIPE 5

PIPE 6

PIPE 7

PIPE 8

PIPE 9

PIPE 10

PIPE 11

PIPE 12

PIPE 13

PIPE 14

PIPE 15

PIPE 16

PIPE 17

THIS DRAWING REPRESENTS VISUAL CONCEPTS AND


CONSTRUCTION SUGGESTIONS ONLY. IT DOES NOT REPLACE
THE KNOWLEDGE AND ADVICE OF A LICENSED STRUCTURAL
ENGINEER. THE DESIGNER IS UNQUALIFIED TO DETERMINE
THE STRUCTURAL APPROPRIATENESS OF THIS DESIGN AND
WILL NOT ASSUME RESPONSIBILITY FOR IMPROPER
ENGINEERING, HANDLING, OR USE. ALL MATERIALS AND
TECHNIQUES USED IN THE CONSTRUCTION OF THESE ITEMS
MUST CONFORM TO THE STRICTEST OF ALL STATE AND LOCAL
FIRE AND BUILDING CODES.

MANDELL WEISS
FORUM THEATRE

VECTORWORKS EDUCATIONAL VERSION

1/4" = 1' - 0"

12'-9 3/8"

18'-8 3/8"

1/4" = 1' - 0"

RAMP -- ISO VIEW


1/4" = 1' - 0"
6'-11 1/8"

5'-2 1/2"

ACT 2 WAGON PLAN VIEW -- A


1/4" = 1' - 0"

3 1/4"
3'-0"

RAMP -- FRONT VIEW


1/4" = 1' - 0"

ACT 2 WAGON PLAN VIEW -- B


1/4" = 1' - 0"

1/4"

6'-0"

10

3 1/4"

11

ACT 2 WAGON FRONT VIEW -- A


1/4" = 1' - 0"

RAMP -- SIDE VIEW


1/4" = 1' - 0"

VECTORWORKS EDUCATIONAL VERSION

1/4"

1/2"

3/4"

19'-5

5'-4 7/8"

1'-9 5/8"

6'-3"

12

ACT 2 WAGON FRONT VIEW -- B


1/4" = 1' - 0"

MR. BURNS

RAMP -- PLAN VIEW

3/4"

1/4" = 1' - 0"

General Notes
1. THE ROLL UP DOOR UNIT SHOULD REMAIN STATIONARY.
2. SR, SL, AND MIDDLE WALL SEGMENT ABOVE ROLL UP DOOR SHOULD BE ATTACHED TO THE GRID WITH A PIPE, BE ABLE TO ROTATE 180 DEGREES, AND LOCK
IN PLACE.
3. SR DOOR IS A SLIDING DOOR.
4. SL DOOR IS A DUAL ACTION SWINGING DOOR. SET OF BLINDS FROM STOCK ATTACHED TO BOTH SIDES OF DOOR, REMOVABLE.
5. THE DOORS HAVE NO MOLDING. THE MATERIAL USED TO FACE THE WALL SHOULD BE ROUNDED OVER IN LIEU OF A FRAME.
6. THE ROLL UP DOOR THIS DRAWING IS BASED ON ON CAN BE FOUND HERE: http://www.rollupdoorsdirect.com/rollupdoor650.html
7. BACK WALL -- ACT 3 KEY:

THE WALL SHOULD BE DECORATED WITH A VARIETY OF FOUND HUBCAPS,

AND LAMPS FOUND IN CARS. THE MORE VARIETY IN STYLE, THE

BETTER.

-CIRCLES REPRESENT HUBCAPS.

-RED RECTANGLES REPRESENT TAIL LIGHTS.

-BLUE RECTANGLES REPRESENT HEAD LIGHTS.

-GREEN RECTANGLES REPRESENT HAZARD LIGHTS OR TURN SIGNALS.

-ALL LAMPS ON THIS WALL ARE PRACTICAL. WIRES CAN BE VISIBLE.


8. ACT 2 WAGONS TO BE DRESSED WITH PILES OF FOUND CAR OBJECTS: BATTERIES, HUB CAPS, TAIL PIPES, MUFFLERS, HEAD/TAIL LIGHTS, TIRES, ECT. THE
IDEA IS THAT WE SEE THESE PILES OF ITEMS THAT ARE THEN TRANSFORMED INTO ART FOR ACT 3. LAMPS USED HERE ARE NOT PRACTICAL.
9. SHEET METAL BOXES ADDED TO SR AND SL WALL SEGMENTS. THEY SHOULD HAVE A HOLLOW BACK TO ALLOW ACCESS TO ELECTRIC PLUGS FOR ACT 3.
10. SL SHEET METAL BOX HAS 1 AND 1 1 /2 CONDUIT RUNNING FROM BOX, FLUSH AGAINST THE WALL.
11. SLIDE PRESENT ONLY FOR ACT 3.
12. SLIDE SHOULD BE DECORATED WITH FOUND CAR PARTS.
13. SLIDE SHOULD CONTINUE AT SLOPE OF VOM.
14. ITEMS DRAFTED IN RED INDICATE THE VOM AND STAGE DECK.

BACK WALL -- PLAN VIEW

6'-0"

BACK WALL -- SIDE VIEW

DRAFTED BY: ACH

1/4" = 1' - 0"

DIRECTOR: JACK REULER

BACK WALL -- ACT 3

UNIVERSITY OF CALIFORNIA SAN DIEGO

1/4" = 1' - 0"

3'-0"

BACK WALL -- ACT 2

14'-0"

SCALE: 1/4" = 1'-0"

1'-4 5/8"

708-408-5957

10'-3"

DATE: 12/15/14

14'-0"

8'-0"

6"

SCENERY AND PROPS

9"

32'-0"

OF 5

10'-0"

3'-7 1/2"

9"

3'-0"

AHEALY87@GMAIL.COM

10'-3"

3'-7 1/2"

TECHNICAL DIR.: CHRIS BORRESON

3'-7 1/2"

SCENIC DESIGNER: ANDRA HEALY

3'-0"

PLATE #

3'-7 1/2"

6'-8 3/4"

6'-8"

2'-9 1/2"

14'-0"

14'-0"

1'-4" 9"

3'-11"

32'-0"

THIS DRAWING REPRESENTS VISUAL CONCEPTS AND


CONSTRUCTION SUGGESTIONS ONLY. IT DOES NOT REPLACE
THE KNOWLEDGE AND ADVICE OF A LICENSED STRUCTURAL
ENGINEER. THE DESIGNER IS UNQUALIFIED TO DETERMINE
THE STRUCTURAL APPROPRIATENESS OF THIS DESIGN AND
WILL NOT ASSUME RESPONSIBILITY FOR IMPROPER
ENGINEERING, HANDLING, OR USE. ALL MATERIALS AND
TECHNIQUES USED IN THE CONSTRUCTION OF THESE ITEMS
MUST CONFORM TO THE STRICTEST OF ALL STATE AND LOCAL
FIRE AND BUILDING CODES.

MANDELL WEISS
FORUM THEATRE

VECTORWORKS EDUCATIONAL VERSION

4
2'-6"

1" = 1' - 0"

9"

BOAT STANTION SIDE VIEW

1" = 1' - 0"

3
1" = 1' - 0"

General Notes
1. MAKE 8 BOAT STANTIONS. MADE FROM FOUND TIRES, AND TUBES OR PIPES
TREATED TO LOOK LIKE TAIL PIPES. EACH SET OF FOUR SHOULD BE
CONNECTED WITH 3/8" CORD OR ROPE TO CREATE RAILING.

VECTORWORKS EDUCATIONAL VERSION

1'-1"

1'-1"

2'-10"

2'-10"

1'-7"

1 1/8"

1'-1"

BOAT STANTION PLAN VIEW

1" = 1' - 0"

DATE: 12/15/14

DRAFTED BY: ACH

708-408-5957

AHEALY87@GMAIL.COM

SCENIC DESIGNER: ANDRA HEALY

1'-8 1/2"

1 1/2"

SCALE: 1" = 1' - 0"

TECHNICAL DIR.: CHRIS BORRESON

UNIVERSITY OF CALIFORNIA SAN DIEGO

BOAT STANTION ISO VIEW

PROPS

BOAT STANTION FRONT EL

DIRECTOR: JACK REULER

1'-1"

PR1

2 7/8"
2'-2"
1/2"

1/2"

1 1/2"

PLATE #

X
2'-6"

2"

2'-2"

1 1/2"
9"

MR. BURNS

2"

1/4"

1 1/2"

THIS DRAWING REPRESENTS VISUAL CONCEPTS AND


CONSTRUCTION SUGGESTIONS ONLY. IT DOES NOT REPLACE
THE KNOWLEDGE AND ADVICE OF A LICENSED STRUCTURAL
ENGINEER. THE DESIGNER IS UNQUALIFIED TO DETERMINE
THE STRUCTURAL APPROPRIATENESS OF THIS DESIGN AND
WILL NOT ASSUME RESPONSIBILITY FOR IMPROPER
ENGINEERING, HANDLING, OR USE. ALL MATERIALS AND
TECHNIQUES USED IN THE CONSTRUCTION OF THESE ITEMS
MUST CONFORM TO THE STRICTEST OF ALL STATE AND LOCAL
FIRE AND BUILDING CODES.

MANDELL WEISS
FORUM THEATRE

VECTORWORKS EDUCATIONAL VERSION

2'-3"

CONVERTIBLE -- FRONT VIEW

1/2" = 1' - 0"


4
1'-3"
10'-9"
1'-3"

15'-0"

CONVERTIBLE -- SIDE VIEW

1/2" = 1' - 0"

General Notes
1. THERE SHOULD BE ENOUGH ROOM UNDER THE CONVERTIBLE FOR SOMEONE
TO CRAWL.
2. WINDSHEILD AND TIRES SHOULD BE REMOVED.
3. EXACT UNDERCARRIAGE STRUCTURE AND PLACEMENT TBD BY PROPS
ARTISAN.

VECTORWORKS EDUCATIONAL VERSION


PROPS

1/2" = 1' - 0"

1'-3"

DATE: 12/15/14

DRAFTED BY: ACH

708-408-5957

AHEALY87@GMAIL.COM

SCENIC DESIGNER: ANDRA HEALY

15'-0"

SCALE: 1/2" = 1' - 0"

TECHNICAL DIR.: CHRIS BORRESON

UNIVERSITY OF CALIFORNIA SAN DIEGO

CONVERTIBLE -- ISO VIEW

PR2

1/2" = 1' - 0"


2

DIRECTOR: JACK REULER

CONVERTIBLE -- PLAN VIEW

PLATE #

3
4'-2"

5'-6"

MR. BURNS

5'-8"

4'-2"

1'-6"

2'-0"

THIS DRAWING REPRESENTS VISUAL CONCEPTS AND


CONSTRUCTION SUGGESTIONS ONLY. IT DOES NOT REPLACE
THE KNOWLEDGE AND ADVICE OF A LICENSED STRUCTURAL
ENGINEER. THE DESIGNER IS UNQUALIFIED TO DETERMINE
THE STRUCTURAL APPROPRIATENESS OF THIS DESIGN AND
WILL NOT ASSUME RESPONSIBILITY FOR IMPROPER
ENGINEERING, HANDLING, OR USE. ALL MATERIALS AND
TECHNIQUES USED IN THE CONSTRUCTION OF THESE ITEMS
MUST CONFORM TO THE STRICTEST OF ALL STATE AND LOCAL
FIRE AND BUILDING CODES.

MANDELL WEISS
FORUM THEATRE

VECTORWORKS EDUCATIONAL VERSION

You might also like