You are on page 1of 49

Harmony Hub800 R2.

6
Ethernet and CES procedures
- A -

DragonWave Proprietary Data

3/18/2016

Objective
The objective of this presentation is to demonstrate how
to configure Ethernet and CES services.

Typical Point to point configuration

DragonWave Proprietary Information

Commissioning Procedure
Steps:

1.
2.
3.
4.

Create Ethernet services


Create CES service
Configure Clock Synchronization
Monitoring TDM performance

DragonWave Proprietary Information

Creating Ethernet Service

1.0 Ethernet Service

DragonWave Proprietary Information

1.1 Create Ethernet Service


Select menu Service Management > Ethernet Service >
Service View and click on Create.

DragonWave Proprietary Information

1.2 Create Ethernet Service


Enter a Service Name, Service type as E-LAN and
SVLAN ID as default and in this case is 51,

DragonWave Proprietary Information

1.3 Create Ethernet Service


Select the 2 ports to be used for the transport service. In this
example we selected CESoP P0/1 and port 0/3. Click Next to
continue.

Select Next to continue

DragonWave Proprietary Information

1.4 Create Ethernet Service


Click Next to continue.

DragonWave Proprietary Information

1.5 Create Ethernet Service


Leave Service Priority as Priority6.
Click Next to continue

DragonWave Proprietary Information

1.6 Create Ethernet Service


Click Apply to create the Ethernet service.

DragonWave Proprietary Information

10

1.6 Create Ethernet Service


When the procedure is complete. Click Close.

DragonWave Proprietary Information

11

End of Creating an Ethernet Service

DragonWave Proprietary Information

3/18/2016

Pg.
12

12

2.0 Circuit Emulation Service

DragonWave Proprietary Information

3/18/2016

Pg.
13

13

2.1 Create CES service


Select menu Service Management > CES Service >
Service View and click on Create.

DragonWave Proprietary Information

14

2.2 Create CES service


Select Operation mode as Advance.
Select PW type as CESoP

DragonWave Proprietary Information

15

2.3 Create CES service


Ensure all timeslot are selected. Confirm Port setting.
Note Remote and Local UDP port setting.

DragonWave Proprietary Information

16

2.4 Create CES service


Enter a Customer VLAN (CVLAN) and Select Add.
Click Next to continue.

DragonWave Proprietary Information

17

2.5 Create CES service


Click Add a Traffic profile if none was created.
Click Next to continue.

DragonWave Proprietary Information

18

2.6 Create CES service


Select the Ethernet service that we created in previous
step. Click Next to continue.

DragonWave Proprietary Information

19

Create CES service

Important Notice
The next step (2.7) is only require when creating the FIRST
CES service.

DragonWave Proprietary Information

20

2.7.1 Create CES service


Enter a Name and Source IP address, Net mask and
Default gateway.

IP address should not be the same class as your management IP address.

DragonWave Proprietary Information

21

2.7.2 Create CES service


Enter Destination IP address. (This is the IP address of the remote CES
service). Click Next to continue.

DragonWave Proprietary Information

22

2.8 Create CES service


Click Apply to create the CES service.

DragonWave Proprietary Information

23

2.9 Create CES service


When the procedure is complete. Click Close.

DragonWave Proprietary Information

24

End of Circuit Emulation Service

DragonWave Proprietary Information

25

3.0 Clock Synchronization

DragonWave Proprietary Information

26

Clock Synchronization
Note
Ethernet port properties PHY master slave selection is
configured as automatic.

TDM clock is derived from the Local PDH (E1 or T1).


If using FPMR, please ensure that SyncE is configure
correctly.
DragonWave Proprietary Information

27

3.1 Configure Clock Synchronization (Local)


Select menu Clock Sync.
Ensure that the Clock Mode is configured as ssm

DragonWave Proprietary Information

28

3.2 Configure Clock Synchronization (Local)


Select menu Clock Sync > Transmit Source Clock for E1/T1/
tab.
Ensure the Output Clock Type is configured as System.

DragonWave Proprietary Information

29

3.3 Configure Clock Synchronization (Local)


Select menu Clock Sync > SSM Configuration for
Ethernet Port tab.

DragonWave Proprietary Information

30

3.4 Configure Clock Synchronization (Local)


Enable SSM on the appropriate Ethernet port.
Highlight row and Click Modify to enable selected port.

DragonWave Proprietary Information

31

3.5 Configure Clock Synchronization (Local)


Select menu Clock Sync > General Sync Configuration.
Click Create to create a sync source.

DragonWave Proprietary Information

32

3.6 Configure Clock Synchronization (Local)


On the pop up window configure at shown.
Ensure the Clock source is the correct PDH (E1/T1).

DragonWave Proprietary Information

33

3.7 Configure Clock Synchronization (Local)


Wait for at least one minute for the Synchronization state
to change to locked.

DragonWave Proprietary Information

34

3.8 Configure Clock Synchronization (Remote)


Select menu Clock Sync.
Ensure that the Clock Mode is configured as ssm

DragonWave Proprietary Information

35

3.9 Configure Clock Synchronization (Remote)


Select menu Clock Sync > Transmit Source Clock for E1/T1/
tab.
Ensure the Output Clock Type is configured as System.

DragonWave Proprietary Information

36

3.10 Configure Clock Synchronization (Remote)


Select menu Clock Sync > SSM Configuration for
Ethernet Port tab.

DragonWave Proprietary Information

37

3.11 Configure Clock Synchronization (Remote)


Enable SSM on the appropriate Ethernet port.
Highlight row and Click Modify to enable selected port.

DragonWave Proprietary Information

38

3.12 Configure Clock Synchronization (Remote)


Select menu Clock Sync > General Sync Configuration.
Click Create to create a sync source.

DragonWave Proprietary Information

39

3.13 Configure Clock Synchronization (Remote)


On the pop up window configure at shown.

Ensure the Type is ethPort and the Clock source is the appropriate Ethernet port.

DragonWave Proprietary Information

40

3.14 Configure Clock Synchronization (Remote)


Wait for at least one minute for the Synchronization state
to change to locked.

DragonWave Proprietary Information

41

End of Clock Synchronization

DragonWave Proprietary Information

3/18/2016

Pg.
42

42

4.0 Monitoring TDM Performance

DragonWave Proprietary Information

3/18/2016

Pg.
43

43

4.1 Monitoring TDM Performance


Select menu Performance

DragonWave Proprietary Information

44

4.2 Monitoring TDM Performance


Select PW from the menu tree and Click Enable
performance monitoring.

DragonWave Proprietary Information

45

4.3 Monitoring TDM Performance


To view Performance data. Select PW Performance from
the menu tree.

DragonWave Proprietary Information

46

End of Monitoring TDM Performance

DragonWave Proprietary Information

47

Worksheet Ethernet Services

Local

Remote

Normal Service
Interfaces
General Information (Basic Mode)
Service Name
Global ID
Service Type
Service VLAN ID
Assign QoS Policy
Priority

DragonWave Proprietary Information

48

Worksheet CES Services


Local

Remote

Notes

CES Service
Select TDM Port
Operation Mode
Time Slot
Port
Remote UDP Port
Local UDP Port
CVLAN
Traffic Profile
Number of Frames
RTP Header Used
Jitter Buffer
Name

Default is 8
Default is Enabled
Default is 4ms

Select Ethernet Service


Basic Setting

Initial setting only


Name
IP Address
Net Mask
Default Gateway

Need to point to the router IP or to self

Config Service
Name
Destination IP
MAC address learning mode

DragonWave Proprietary Information

Leave as Default

49