Gas Turbine Governor Model Data Sheet

Submit this form as a pdf attachment by e-mail to: market.registration@ieso.ca or submit by mail:
using the address given on the IESOs Web site (www.ieso.ca)
All information submitted in this process will be used by the IESO solely in support of its obligations
under the Electricity Act, 1998, the Ontario Energy Board Act, 1998, the Market Rules and
associated policies, standards and procedures and its licence. All submitted information will be
assigned the appropriate confidentiality level upon receipt.
Terms and acronyms used in this Form that are italicized have the meanings ascribed thereto in
Chapter 11 of the Market Rules.

Gas Turbine Governor (GAST)

SPEED

PMECH

GAST

Speed

Power

Speed
SPEED

D urb
t

VMAX

Load Ref. +
VAR(L)

Low
Value
Gate

1

1 + T1s

1

1 + T2s

PMECH

VMIN

KT

1

1 + T3s

Load Limit

IMO-FORM-1476 v.3.0
REV-15-02

Confidential

Page 1 of 2

Market Participant Name

Market Participant ID #

This model is located at system bus

# IBUS

machine

# I

This model uses CONs starting with

# J

and STATEs starting with

# K

and VAR

# L

CONs #

Value

Description

STATEs #

Description

R (Speed Droop)

Fuel Valve

J+1

T1 (>0) (Seconds)

K+1

J+2

T2 (>0) (Seconds)

K+2

Fuel Flow
Exhaust
Temperature

J+3

J+4

J+5

T3 (>0) (Seconds)
Ambient Temperature Load
Limit, AT
KT

VAR

Description

J+6

VMAX

Load Reference

J+7

VMIN

J+8

Dturb

IBUS, 'GAST', I, R, T1, T2, T3, AT, KT, VMAX, VMIN, Dturb

Page 2 of 2