You are on page 1of 2

SONGLE RELAY

SRD

RELAY ISO9002

1. MAIN FEATURES
Switching capacity available by 10A in spite of
small size design for highdensity P.C. board
mounting technique.
UL,CUL,TUV recognized.
Selection of plastic material for high temperature and
better chemical solution performance.
Sealed types
available.
Simple relay magnetic circuit to meet low cost of
mass production.

2. APPLICATIONS
Domestic appliance, office machine, audio, equipment, automobile, etc.
( Remote control TV receiver, monitor display, audio equipment high rushing current use application.)

3. ORDERING INFORMATION
SRD
Model of relay
SRD

XX VDC
Nominal coil voltage

S
Structure
S:Sealed

L
Coil

type

L:0.36W

F:Flux free type

D:0.45W

03050609122448VDC

4. RATING
CCC
CCC
UL /CUL
TUV

FILE NUMBER:CQC03001003729 7A/240VDC


FILE NUMBER:CQC03001003731 10A/250VDC
FILE NUMBER: E167996
10A/125VAC 28VDC
FILE NUMBER: R50056114
10A/250VAC 30VDC

5. DIMENSION(unit:mm)

DRILLING(unit:mm)

WIRING DIAGRAM

C
Contact form
A:1 form A
B:1 form B
C:1 form C

6. COIL DATA CHART (AT20 C)


Coil
Coil
Nominal Nominal
Power
Pull-In
Coil
Voltage Voltage Current Resistance Consumption Voltage
Sensitivity
Code
(VDC)
(mA)
(W)
(VDC)
()
10%
SRD
03
03
120
25
abt. 0.36W 75%Max.
(High
05
05
71.4
70
Sensitivity)
06
06
60
100
09
09
40
225
12
12
30
400
24
24
15
1600
48
48
7.5
6400
SRD
03
03
150
20
abt. 0.45W 75% Max.
(Standard)

05
06
09
12
24
48

05
06
09
12
24
48

89.3
75
50
37.5
18.7
10

55
80
180
320
1280
4500

Drop-Out Max-Allowable
Voltage
Voltage
(VDC)
(VDC)
10% Min.

120%

10% Min.

110%

abt. 0.51W

7. CONTACT RATING

9.REFERENCE DATA
Type

Item
Contact Capacity
Resistive Load (cos=1)
Inductive Load
(cos=0.4 L/R=7msec)
Max. Allowable Voltage
Max. Allowable Power Force
Contact Material

SRD
FORM A

FORM C
7A
30VDC
10A 125VAC
10A
250VAC
3A 120VAC
3A 28VDC
250VAC/110VDC
800VAC/240W
AgCdO

10A 30VDC
10A 240VAC

50
45
40
35
30
25

5A 120VAC
5A 28VDC

20
15
10

250VAC/110VDC
1200VA/300W
AgCdO

8. PERFORMANCE (at initial value)


Type
Item
Contact Resistance
Operation Time
Release Time
Dielectric Strength
Between coil & contact
Between contacts
Insulation Resistance
Max. ON/OFF Switching
Mechanically
Electrically
Ambient Temperature
Operating Humidity
Vibration
Endurance
Error Operation
Shock
Endurance
Error Operation
Life Expectancy
Mechanically
Electrically
Weight

Coil Temperature Rise

5
0
0.0
0.7

0.1
0.8

0.2

0.3

0.4

0.5

0.6

Coil Power (W)

Operation Time
12

10

SRD

Operation tim e
8

100m Max.
10msec Max.
5msec Max.

6
4

Releas e e
tim

1500VAC 50/60HZ (1 minute)


1000VAC 50/60HZ (1 minute)
100 M Min. (500VDC)

0
0.0
0.7

0.1
0.8

0.2

0.3

0.4

0.5

0.6

Coil Power (W)

Life Expectancy
AC120V/DC24V cos=1
100

300 operation/min
30 operation/min
-25
C to +70 C
45 to 85% RH

5
3
2
10
5
3

10 to 55Hz Double Amplitude 1.5mm


10 to 55Hz Double Amplitude 1.5mm

2
1

10

12

Current of Load (A)

100G Min.
10G Min.

Life Expectancy
100
5

10 operations. Min. (no load)


105 operations. Min. (at rated coil voltage)
abt. 10grs.

3
2

AC : 120V TV-5

10
5
3
2
1
0
4

1
5

Current of Load (A)

6
8

You might also like