1. Electric connectors, emergency devices, and 5. Shear wire is used where it is necessary to
other pieces of electrical equipment in aircraft are purposely break or shear the wire to permit operation or
secured with wire when specified on engineering actuation of emergency devices. Shear wire is a thin,
drawings or specified in the applicable aircraft single strand, easily breakable wire used to secure
maintenance handbook in order to prevent accidental emergency devices.
loosening.
NOTE
2. This chapter outlines the recommended
procedures for wiring MS electric connectors and General purpose shear wire shall be 0.020 inch
emergency devices such as switches, switch guards, and diameter.
handles which operate ejection seats, emergency bomb
releases, fire extinguishers, etc. General practices for Seal Wire
safety wiring are specified in Military Standard
Drawing MS33540 and wire identification is provided 6. Seal wire is the same as shear wire except that
in Table 9–1. the ends of the wire are sealed with a lead seal. Seal
wire is used to secure emergency devices such as fire
REFERENCE SPECIFICATIONS extinguishers, oxygen regulators, etc., to prevent
tampering with or use of these devices without
3. The following specifications are applicable to indication.
Lock Wire, Shear Wire and Seal Wire:
Metallic Seals
SAE AS 50881 Wiring Aerospace Vehicle
NASM20995 Wire, Safety or Lock 7. Metallic seals are not to be used on airborne
components, equipment or systems. When anti-
NASM33540 Safety Wiring and Cotter tampering seals are required for lock wire, a bright gloss
Pinning, General Practices for paint system is to be used. The paint is to be applied in
such a manner that will provide a visible indication that
the lock wire has been tampered with.
DEFINITIONS
GENERAL PROCEDURES FOR LOCK, SHEAR
Lock Wire
AND SEAL WIRING
4. Lock wire is normally a single strand steel wire
installed by twisting to double strand. It is used to
secure parts against inadvertent opening or loosening in
areas of high vibration such as the engine compartment.
Electrical connectors are lockwired or safety wired in EYE PROTECTION IS REQUIRED WHEN
such high vibration areas. (Refer SAE AS 50881) USING PLIERS THAT CUT OR TRIM AND
SHALL BE WORN WHILE INSTALLING OR
NOTE REMOVING SAFETY WIRE. KEEP FINGERS
AWAY FROM JAWS AND CUTTING EDGE.
Use 0.032 inch lockwire for general purpose
lockwiring. 0.020 inch lockwire may be used on
parts having a nominal hole diameter of less than
0.045 inch or on closely spaced screws and bolts
of 0.250 inch (6.35mm) diameter or less.
LOCKWIRE ENDS MUST BE BENT UNDER
NOTE TO PREVENT INJURY. CARE SHOULD BE
TAKEN NOT TO CONFUSE STEEL WITH
Connector plugs with self-locking coupling rings ALUMINIUM WIRE.
are designed for high vibration environments and
do not have lock wire provisions.
Table 9–1 Safety Wire – Identification
AL 1 1
AAP 7045.002-1 Sect 2 Chap 9
Length
2 AL 1
AAP 7045.002-1 Sect 2 Chap 9
Make sure wire does not become kinked or 13. Install wire so that the wire will be in tension if
nicked during twisting operation. If wire is the part loosens. Twist wire together so that it is tight,
damaged, replace with new wire. but do not overstress wire as it may break under load or
vibration.
12. Twist wire with a wire twister as follows (see Lock Wiring Electrical Connectors and Backshells
Figure 9–3):
NOTE
AL 1 3
AAP 7045.002-1 Sect 2 Chap 9
4 AL 1
AAP 7045.002-1 Sect 2 Chap 9
17. If no fillister head screw or safety wire tab is b. To highlight the selection or operation of
available for attaching lock wire, secure wire to drilled a particular service or function.
hole in structure not more than 6 inches (15cm) from
connector, as shown in Figure 9–8. Use same procedure
as described in Para 14.