ASME Power
May 2-4, 2006 Atlanta, GA
PWR2006-88056
Advantages Captures the results of all the Eliminates uncertainties due to unknown
modernizations and upgrades by test steam cycle changes not caused by
data modernizations and upgrades, thus eliminated
unknown bottoming cycle test errors that can
Industry accepted test protocol, ASME be significant
PTC 46
Eliminates manpower required to develop
overall plant correction curves (but does not
eliminate the need to develop a heat balance
model, although one may already exist which
might just need some fine tuning)
Performance Loss
Performance
Improvement
due to Upgrade
Variable
Degradation
Recovery Due
to Outage
Operating Hours
ANNEX A
Values for:
Delta BTU and Delta Power
PW1, PW2, ….
Improvement
T1-2, T2-3, ….
After Upgrade
Q3
Q3n
T4-5
MutuallyPlant Power
Agreed PlantOutput
Power Levels
Output Levels
hours/year plant
operates between
PW4 and PW5