Professional Documents
Culture Documents
Stability Analysis For Shallow Foundations - Eurocode 7 and The New Generation of DIN Codes
Stability Analysis For Shallow Foundations - Eurocode 7 and The New Generation of DIN Codes
B. Schuppener
Federal Waterways Engineering and Research Institute, Karlsruhe, Germany
U. Smoltczyk
Böblingen, Germany
ABSTRACT: The relevant features of Eurocodes 0 and 7 – the concept of limit states and the partial
factor method – are described. In particular it is shown how the factors of safety are to be introduced
in the three approaches proposed by the new version of Eurocode 7 for the verification of ultimate
limit states. The approach adopted in the new generation of geotechnical DIN codes and the basic
principles of the new DIN 1054 are then presented. The main features are that the partial factors on the
actions of the ground and of the structure have the same value and only one single calculation is re-
quired to verify a limit state. Moreover Germany favours the approach, in which the partial factors are
neither applied to ϕ´ or c´ nor directly to the actions but to the action effects and the characteristic
values of the resistances in the last step of the verification of the ultimate limit states of geotechnical
structures. Based on a long tradition three design situations are introduced to account for different
probabilities of failure and the need for different safety levels. The procedures and results of the three
approaches specified in Eurocode 7 are compared taking the dimensioning of the width of the founda-
tion of a cantilever stem wall as an example.
1 INTRODUCTION
In future, verification of ultimate limit states by calculation will be performed in accordance with the
partial factor concept throughout the entire construction sector in Europe. To put it simply, the concept
states that it must be verified that the design value Rd of the resistance is greater than the design value
Ed of the actions or the action effects:
Rd ≥ Ed
However, it turned out that the member states were unable to reach a consensus of opinion on the
implementation of this limit state equation in geotechnical design in the draft of Part 1 of Eurocode 7
(ENV 1997-1, 1994). The principal criticism expressed not only by Germany but also by other Euro-
pean countries concerned the intended procedure for verifying the stability of foundations by calcula-
tion. The procedure involves the use of two different stability analyses – the investigation of cases B
and C. Firstly, this attracted criticism as it would have doubled the amount of effort required to verify
the stability of foundations by calculation after implementation of EC 7. Secondly, the safety philoso-
phy on which the procedure was based was strongly criticised in Germany and other member states
(Gudehus and Weissenbach, 1996, Schuppener et al., 1998, Stocker, 1997, Weissenbach et al. 1999).
After lengthy discussions, a compromise was reached by which the new version of EC 7 would in
future not specify a single procedure only but would give member states a choice of three different
approaches to verifying the stability of foundations by calculation. Each state would then have to
specify, in a National Application Document (NAD), which of the three approaches was to be applied.
In a NAD the suggested partial safety values of EC7 will either have to be confirmed or altered if nec-
essary according to national experience.
-1-
2 LIMIT STATES AND PARTIAL FACTOR METHOD OF EUROCODES 0 AND 7
The revised EC 7 and the new versions of the German geotechnical codes are based on Eurocode 0
(prEN 1990, draft July 2000) which contains provisions that are applicable to all areas of building and
civil engineering and thus do not have to be specified again separately in each Eurocode. In particular,
this includes the definition of the limit states for which verification is required in building and civil
engineering and how the partial factors are to be applied in stability analyses and introduced into limit
state equations. There are two possible approaches when determining the design values of resistances
and actions of the ground:
In the Material Factor Approach the partial factors γm are applied to the characteristic values of the
material properties of the structure or the ground to determine the design value of the resistance Rd of
the structure or the ground or the design value of the action of the ground Ed. Thus the following
equations are derived for resistances and actions of the ground:
Rd = R {(tan ϕk) / γm, ck / γm}
Ed = E {(tanϕk) / γm, ck / γm}
where:
R is a function describing the resistance of the ground - e.g. passive earth pressure, bearing capacity
or sliding resistance of a footing - determined with factored values of the characteristic shear pa-
rameters ϕk and ck,
E is a function describing the action of the ground - e.g. active earth pressure - determined with fac-
tored values of the characteristic shear parameters ϕk and ck,
γm is the partial factor for the shear parameters of the ground taking account of the possibility of unfa-
vourable deviations of the shear parameters from their characteristic values and uncertainties in
modelling the resistance and/or actions.
In the Resistance and Action Factor Approach the design values of the resistances Rd and actions Ed
are determined by applying the partial factors γR and γE to the characteristic values of the resistance Rk
and of the actions or action effects Ek of the structure or the ground:
Rd = Rk / γR
Ed = Ek ⋅ γE
where
γR is the partial factor for the resistance of the ground, taking account of the possibility of unfavour-
able deviations of the shear parameters from their characteristic values and uncertainties in model-
ling the resistance,
γE is the partial factor for the actions or action effects taking account of the possibility of unfavourable
deviations of the shear parameters from their characteristic values and uncertainties in modelling
the resistance and/or actions.
The Material Factor Approach was the only approach specified in the previous version of EC 7
(ENV 1997-1 (1994)). As the Resistance and Action Factor Approach has now been introduced in
EC 0 (prEN 1990, draft July 2000) for building and civil engineering as a whole, there are no longer
any obstacles to applying it in geotechnical engineering and including it in the new version of EC7.
This now enables two other verification approaches to be included as alternatives to the methods used
hitherto in Case B and Case C (see table 1).
-2-
Table 1: Sets of partial factors for the approaches 1 to 3 to verify ultimate limit states of foundations
and retaining structures according to EC0 and EC7 –1
Apart from the basic concepts specified in EC0 and EC7, priority has been given in German geotech-
nical coding to the principle that the concept applied in the verification of geotechnical limit states
should be as similar as possible to that applied in the verification of structural limit states. In most
cases the same engineer will perform the geotechnical as well as the structural verifications for foun-
-3-
dations and retaining walls, so switching from one concept to another must be avoided. This meant
that
- the values of the partial factors on the actions of the ground and those of the structure should be the
same (see table 2) and
- only a single calculation based on the characteristic values of the actions and the resistances should
suffice to verify a limit state – instead of the two Cases B and C proposed in the draft of EC7 pub-
lished in 1994.
Moreover, Germany favoured the Resistance and Action Factor Approach in which the safety fac-
tors are neither applied to ϕ´ or c´ nor directly to the actions but to the characteristic action effects
(internal forces, bending moments, etc.) and the characteristic values of the resistances in the last step
of the verification of the ultimate limit state.
Design Situations to account for different probabilities of failure and the need for different safety
levels constitute the fourth important feature of German geotechnical coding (also see prEN 1990) in
accordance with a long tradition of design situations in geotechnical DIN codes and other geotechnical
recommendations. There are Design Situation 1 (DS1) for permanent situations, Design Situation 2
(DS2) for the stage of construction or transient structures and Design Situation 3 (DS3) for accidental
situations concerning both actions and resistances (see table 2 and 3).
Experience in Germany has shown that the former global safety concept has hitherto ensured that
foundations could be designed economically and with an adequate degree of safety. It is for this reason
that the safety level used hitherto in the global safety concept has been selected as a base quantity and
the partial factors of the new partial safety concept calibrated against it. This was done by “splitting”
up the global factor η in two partial factors – γR for the resistance and γG,Q a mean value for permanent
and variable actions and action effects:
η = γR ⋅ γG,Q (1)
The partial factors for the resistance of the ground γR were then determined by means of equation
(1), inserting the value η of the old global safety concept and the prescribed partial safety factors γG,Q
for permanent and variable actions specified in Eurocode 0 (ENV 1990, draft October 1999):
γR = η / γG,Q
The steps of the design procedure proposed by the German geotechnical DIN codes are very similar to
those put forward by structural engineers:
1. Estimated sizing and assessment of the static design system of the geotechnical structure (footing,
retaining wall, strutted sheet pile wall, piles etc).
2. Determination of the characteristic actions of the structure and of the soil, i.e. the most realistic and
probable actions.
-4-
3. Determination of the characteristic action effects Eki, e.g. strut-, anchor- or supporting-forces, the
resultant characteristic forces in the base level of a footing or in the earth pressure support of a wall
etc.
4. Determination of the characteristic resistances Rki e.g.:
- for structural elements: the characteristic bending moment or the characteristic compressive
strength according to the standards for the considered material,
- for soil: the characteristic bearing capacity of shallow foundations, the characteristic passive
earth pressure or the characteristic bearing capacity of piles, anchors and nails determined by
calculations, tests or comparable experience.
5. Verification of the ultimate limit state in every relevant cross section of the structure and in the
soil:
− The design effects of the actions Edi are obtained by multiplying the characteristic effects Eki of
the actions by partial safety factors e.g. for permanent structures with γG = 1.35 for permanent
actions and γQ = 1.50 for variable actions (see table 2)
− The design resistances Rdi are obtained by dividing the characteristic values Rki by their corre-
sponding safety factors for the structure (e.g. for steel see Eurocode 2 (EN 1992 (1991)), for
concrete see Eurocode 3 (EN 1992 (1992)) and for soil (see table 3).
The basic equation:
Σ Rdi ≥ Σ Edi
is verified in the final step of the ultimate limit state analyses. If it is not fulfilled the sizing shall be
improved.
The merits of this concept for the geotechnical and structural verifications of foundations and re-
taining walls are:
1. As this calculation works with characteristic values of actions, which are also used for the verifica-
tion of the serviceability limit state, no separate calculation is necessary for the input of the deter-
mination of the displacements.
2. The concept is open for all analytical methods of verification. Steps 3 and 4 allow for the classical
methods, the theory of elasticity, ultimate load method, spring models, the finite element method
and cinematic element method.
3. The procedure corresponds to the concept of the Eurocodes for structural engineering (EN 1992
Eurocode 2 (1991), EN 1993 Eurocode 3 (1992). Thus geotechnical engineering does not need a
separate concept as proposed in the 1994 version of Eurocode 7. The procedure can therefore easily
be understood and adopted by students and practising engineers, which makes it very user-friendly.
-5-
1)
pk = 5 kN/m²
β = 20°
Fictitious wall to
determine the
h = 6,0 m action due to
active earth
pressure
1)
This part of the variable action
0,95 m 0,7 m must only be considered in the
structural design of the wall
B=?
Figure 1: Cantilever stem wall, dimensions and loads
-6-
Table 4: Results of the comparative stablility calculations
Approach 1 Approach 2 Approach
Case B Case C DIN 1054 EC7 3
Width of foundation B [m] 5,00 5,00 3,40 3,80 4,90
Verification of safety against bearing resistance failure
Vertical component Vd of the resultant 806 717 605 601 773
action effect in the base level [kN/m]
Inclination of the resultant action effect 0.34 0.40 (0.36) 0.39 0.37
tanδ=Hd/Vd (Hk/Vk)
Bearing resistance RGb,d [kN/m] 2177 734 616 627 767
Degree of mobilisation fGb = Vd / RGb,d 0.37 0.98 0.98 0.96 1.01
Verification of safety against sliding
Sliding resistance RSl,d [kN/m] 559 393 291 327 422
Design value of the horizontal actions ΣHd 301 305 260 270 306
[kN/m]
Degree of mobilisation fGl = ΣHd /RSl,d 0.55 0.78 0.89 0.83 0.73
The main reason for the much lower foundation width that results when applying Approach 2 is the
much higher design ground bearing resistance RGb,d that results for the same loads and dimensions
when applying the two other approaches. In the approach laid down in DIN 1054, the design ground
bearing resistance RGb,d is determined by first calculating the characteristic ground bearing resistance
RGb,k using the characteristic shear parameters ϕ’k and c’k. The design bearing resistance RGb,d = RGb,k/
γGb is then obtained by dividing the the characteristic ground bearing resistance by the partial factor for
the bearing resistance failure, γGb = 1.40. In contrast, RGb,d is determined using the design values of the
shear parameters ϕ’d and c’d in approaches 1 and 3. In the case we are dealing with here, a reduction in
the angle of friction ϕ’k = 32.5° to ϕ’d = 27.0° lowers the ground bearing resistance to around half of
that determined when a characteristic angle of friction ϕ’k = 32.5° is applied. The greater foundation
widths obtained using approaches 1 and 3 are thus due on the one hand to the additional safety in-
cluded when dealing with the favourable permanent actions and on the other hand to the greater level
of safety in respect of the bearing resistance resulting from the proposed partial factors for the shear
parameters.
The difference between approach 1 (Case C) and approach 3 when establishing the required foun-
dation width B is insignificant in the example we are dealing with here. Approach 3 results in a some-
what smaller width B despite the higher vertical component Vd of the action effect in the base level of
the foundation as the angle of the resultant (tan δ) decreases and thus the bearing resistance increases,
which influences the results in the way shown here.
To sum up, it can be said that a far more economical shallow foundation design is obtained when
following Approach 2 with the partial factors specified in DIN 1054. The partial factors for the actions
due to the structure and the ground as well as those for the ground resistances have been specified such
that the level of safety provided by the global safety concept used hitherto is maintained. The safety
level of this concept has been tried and tested in practice for decades. Thus, applying the partial fac-
tors specified in DIN 1054 to the design of geotechnical structures not only ensures an adequate de-
-7-
gree of safety, it is also considerably more economical, as the comparison with the other approaches
has illustrated.
The detailed numerical calculations according to the three approaches can be ordered from the
author by email: bernd.schuppener@baw.de.
5 REFERENCES
DIN 4017-100 (1996) Berechnung des Grundbruchwiderstandes von Flachgründungen Teil 100:
Berechnung nach dem Konzept mit Teilsicherheitsbeiwerten, Beuth, Berlin
DIN 4085-100 (1996) Berechnung des Erddrucks Teil 100: : Berechnung nach dem Konzept mit
Teilsicherheitsbeiwerten, Beuth, Berlin
DIN 1054 (1999) Standsicherheitsnachweise im Erd- und Grundbau, Draft February 2000, Beuth,
Berlin
ENV 1997-1 Eurocode 7 (1994): Geotechnical design, Part 1: General rules. European Committee for
Standardisation (CEN) Brussels
EN 1997-1 Eurocode 7 (2000): Geotechnical design, Part 1: General rules. European Committee for
Standardisation (CEN) Brussels, draft April 2000
prEN 1990 Eurocode 0 - Basis of design (1999), European Committee for Standardisation (CEN)
Brussels, draft July 2000
EN 1992 Eurocode 2 (1991) Design of concrete structures, European Committee for Standardisation
(CEN) Brussels
EN 1993 Eurocode 3 (1992) Design of steel structures, European Committee for Standardisation
(CEN) Brussels
Gudehus, G. & Weißenbach, A. (1996) Limit state design of structural parts at and in the ground,
Ground Engineering
Schuppener, B., Walz, B., Weißenbach, A., Hock-Berghaus, K. (1998), EC7 – A critical review and a
proposal for an improvement: a German perspective, Ground Engineering,
Simpson, B. & Driscoll, R. (1998) Eurocode 7 – a commentary. Construction Research Communica-
tions Ltd., London
Stocker, M. (1997) Eurocode 7 – all problems solved? European Foundations, a Ground Engineering
Publication
Weißenbach, A., Gudehus, G. and Schuppener, B. (1999) Proposals for the application of the partial
safety factor concept in geotechnical engineering, geotechnik special issue: German contributions
to European standardization
-8-