Here I am mentioning the script that will connect to Quality Center. For this,your system must have QC api dll/QC client installed.
REM Define the Domain name
DomainName =”DEFAULT”
REM ‘Define the ProjectName
ProjectName =”Automation” REM ‘ login username UserName =”Rajeev Nandwani” REM ‘ login password Password =”RNSystem00″ REM ‘ Server name with Port ServerName =”QAserver:8080″
Rem Create QC Connection Object
Set objTDConnection = CreateObject(“TDApiOle80.TDConnection.1″) Rem Connect with server QCServerName =”http://”& ServerName &”/qcbin” objTDConnection.InitConnectionEx QCServerName Rem Connect with Project objTDConnection.ConnectProjectEx DomainName, ProjectName, UserName, Password
Rem Check login Success or not
If objTDConnection.loggedin Then
msgbox “Connect successfully “
else msgbox “not connect with Quality Center Check username /Password/Domain name /Project Name “ End If