DISEÑO Y SERVICIOS PARA LA INGENIERIA

GRUPO DICA
MÉXICO, D.F, 18 DE ENERO DEL 2011

ASUNTO: REPORTE DE CONSIDERACIONES PARA ANALISIS Y DISEÑO DE ANCLAS EN LA BASE


DE LA COLUMNA DE CELOSIA QUE SOPORTA UN TANQUE DE GAS-ACEITE. PROYECTOS
OAXACA II, III, IV.

DIAGRAMA DE CUERPO LIBRE:

W=1.5 TON PESO DEL TANQUE

1.0 M

F= 2.0 TON COEFICIENTE SISMICO EN


(PESO CELOSIA) OAXACA:
C=1.0 PARA TANQUES ELEVADOS
3.0 M

MOMENTO DE VOLTEO DEL CONJUNTO: W X h x c + F X h x c.

1.5 TON X 1.0 X 6.5m =9.75 T-M


2.0 TON X 1.0 X 3.0m =6.00 T-M
SUMA =15.75 T-M

ESTOS ELEMENTOS MECANICOS SE TRANSFORMAN EN LA BASE DE LA CELOSIA EN UN PAR


DE FUERZAS, UNA A TENSION Y OTRA A COMPRESION: CON 1.0 M DE BRAZO DE
PALANCA-GRAMIL

NACAXOC MZ. 31 LT. 56 COL. ADOLFO RUIZ CORTINEZ, MÉXICO, D. F. C.P. 04630
TEL Y FAX: 54 21 43 69 E-mail: bayghen@prodigy.net.mx
DISEÑO Y SERVICIOS PARA LA INGENIERIA
GRUPO DICA
BRAZO DE PALANCA EN LA BASE ENTRE LAS PATAS DE LA COLUMNA DE LA CELOSIA:
1000
1000mm
mm

GRAMIL GRAMIL

880mm
102

60 60

10 102

15.75 T-M =17.89 EN (+) Y EN (-)


0.88
ESTE VALOR DE TENSION LO AFECTAMOS POR UN FACTOR DE TORSION ACCIDENTAL Y DE
IMPACTO DE 1.33

17.89 TON X 1.33 = 23.79 TON EN TENSION

ESTA FUERZA LA DIVIDIMOS ENTRE EL NUMERO DE ANCLAS Y NOS DA LA TENSION POR


ANCLA.

23,790 KG = 3,965 KG / ANCLA


6 PZAS.

AREA DE 1 ANCLA 7/8” DE DIAMETRO = 3.87 CM2

ESFUERZO DE TRABAJO PARA DISEÑO:

3,965 KG = 1024.5 KG/CM2


3.87 CM2

PASA CON REDONDO LISO DE ACERO A-36, fy= 2530 KG/CM2.

LA FUERZA SISMICA HORIZONTAL A NIVEL TANQUE

F = 1.5 X 1.3 = 1.95 TON

LA FUERZA SISMICA HORIZONTAL POR CONCEPTO DE ESTRUCTURA METALICA

F= 2.0 TON X 1.3 = 2.6 TON

NACAXOC MZ. 31 LT. 56 COL. ADOLFO RUIZ CORTINEZ, MÉXICO, D. F. C.P. 04630
TEL Y FAX: 54 21 43 69 E-mail: bayghen@prodigy.net.mx
DISEÑO Y SERVICIOS PARA LA INGENIERIA
GRUPO DICA
EL ACUMULADO NOS DA EL VALOR DE LA CORTANTE HORIZONTAL EN LA BASE DE LA
COLUMNA DE LA CELOSIA:

1.95 TON + 2.6 TON = 4.55 TON

LA CARGA AXIAL ES LA MISMADEL PESO DEL TANQUE Y SU PLATAFORMA, MAS EL PESO DE


LA CELOSIA Y SU ESCALERA MARINA, LA CUAL GRAVITA EN LA CELOSIA.

W TANQUE______________________ 1.5 TON

W CELOSIA ESCALERA_____________ 2.0 TON

W TOTAL_______________________ 3.5 TON

RESPETUOSAMENTE,

JESÚS GARCÍA FLORES FCO. LÓPEZ BAYGHEN, SR.


GERENTE TÉCNICO DIRECTOR.
D.R.O. # 0335