You are on page 1of 1
D2- Solenoid valve unit The solenoid valve unit consists of : EV2 Discharge solenoid valve EV1 Bow rinsing and closing solenoid valve Manual discharge valve D Manual bow! closing valve Valves D and C are used manually for carrying out partial or total discharges in the event of a programmer failure or before stopping the separator at the end of a shift after having turned off the feed pump. For partial discharges proceed as follows: -a- Open valve D; -b- Quickly open and close valve C; -c- Finally after 10"-20" close valve D. For total discharges proceed as follows: -a- Open valve C for 1+2 seconds; -b- Open valve D for 10-20" to close the bowl. ‘Should the total di be executed at separator's st i “D” valve. will neces: The solenoid valves EV1 and EV2 operate according to the adjustments made on the board. ‘At least once a year, especially if the water has impurities, it is advisable to disassemble and clean solenoid valves EV1 and EV2. 34. di 113 (— Frautech an >) Print 05/08 cod. 1070101311