D2- Solenoid valve unit
The solenoid valve unit consists of :
EV2 Discharge solenoid valve
EV1 Bow rinsing and closing solenoid valve
Manual discharge valve
D Manual bow! closing valve
Valves D and C are used manually for carrying out partial or total discharges in the event of
a programmer failure or before stopping the separator at the end of a shift after having
turned off the feed pump.
For partial discharges proceed as follows:
-a- Open valve D;
-b- Quickly open and close valve C;
-c- Finally after 10"-20" close valve D.
For total discharges proceed as follows:
-a- Open valve C for 1+2 seconds;
-b- Open valve D for 10-20" to close the bowl.
‘Should the total di be executed at separator's st
i “D” valve.
will neces:
The solenoid valves EV1 and EV2 operate according to the adjustments made on the
board.
‘At least once a year, especially if the water has impurities, it is advisable to disassemble
and clean solenoid valves EV1 and EV2.