Professional Documents
Culture Documents
Sdtork: 3000-SERIES Data Sheet Ref. No: SD-3000-001 Electrical Actuator Technical Specifications
Sdtork: 3000-SERIES Data Sheet Ref. No: SD-3000-001 Electrical Actuator Technical Specifications
No :
SD-3000-001 sdtork ®
Electrical Actuator Technical Specifications Quotation Ref. No
Quotation Date
2. MAKE Sdtork
3 APPLICATION
3. ACTUATOR DETAILS
4.2 Model
4.15 Duty
5
MOTOR DETAILS
5.1 Type. TEFC Induction Motor.
5.5 Rating
5 OPTIONAL ACCESSORIES
5.7 Local Push Button Refer Basic Specification Sheet Provided / Not Provided
Station
5.8 Space Heater Provided / Not Provided
7. GENERAL POINTS
SPECIAL NOTES:
• 2 nos. Travel limit switches of (1 NO + 1 NC) / (2NO+2NC) & 2 nos. Torque limit of 1 NO + 1
NC (2NO+2NC) potential free type, current rating: 5A-250 VAC/0.46A-250VDC. All switches are
internally wired & brought out to common terminal box.
• Drive motor suitable for 3 phase 415 V +/- 10 % , 50 Hz +/- 5 %, combined variation +/- 10 % AC
power supply, Motor type TEFC
• Manual operation : Sdtork actuator is provided with manual hand wheel for manual operation with
auto declutching system. Selector fork shows two position one is “Hand mode “& second is “Motor
mode”. When we put hand mode position motor drive gets dis-engaged & drive shaft gets engage with
hand wheel.
When motor is switched on, selector fork automatically goes in normal i.e. motor mode position.
The drive shaft gets dis-engaged from hand wheel & gets engaged with motor drive automatically. This
gives motor overriding feature.
• A short time break-away torque, which is considerably higher than the tripping torque is mostly
required to clear jammed parts in Knife gate valve in case of slurry application. This is possible by
“Hammer Blow Effect” which is inherent feature of SDTORK actuator.
• The actuator is provided with a built-in mechanical position indicator. It gives continuous faithful
indication directly on the actuator. The dial provided with marks to indicate the direction of opening &
closing of the valve and Actuator.
• SDTORK actuators are provided with weatherproof protection confirms to IP-65 Enclosure.
• For regulating/modulating application Actuator will be S4-duty (S4 - 25 %, 600 c/h) & for on-off
application actuator will be S2-15 min (60 starts/hr) as per DIN 3210/IS325.
Sdtork actuators are available with various designs of output shaft to meet the different types of
coupling with final control element required by various manufacturers as per DIN 3210. Followings are
different types of couplings available with SDTORK
• ELECTRIC CONNECTION:
The electric connection of the actuators is effected either through terminals or plugs.
The motor of the design with terminal connection is directly connected, where as switching & signaling
device is wired to the terminal strip. The terminal strip is suitable for connecting wire of cross-sections
up to 2.5 sq. mm.
• OPERATING POSITION:
Sdtork electric actuator can operate in any position provided that the axis of electric motor remains
horizontal. The actuators can be used in a position with the electric motor up-word position also.
All three Phase actuator do need control panel to operate & control the movement of final control
element. This control can achieve by means of local control panel. Local control panel are available in
two types of configuration one is wall mounted design constructed in sheet metal & other will be integral
construction type. This will be equipped with following components:
Main switch
MCB on fuses for power & control circuits
Contactors
Push buttons for open / stop / close commands
Auto/ Manual or Local/Remote selector switch
Indicating lamps for various indications such as power on, opened,
closed, fault operation etc.
Over load relay cum single phase preventor
Electronic Positioner** (Modulating/Regulating application)
The sdtork electric actuator will be supplied with resistance transmitter of 100-500 Ω ( alternative values
are also available) or a current transmitter with a unified signal of 4-20 m A. The current transmitter uses a
two-wire connection, no power supply being built in the actuator. In the control design variant, it is
advisable to use a current position transmitter only. The maximum load resistance is 500 Ω. The supply
voltage of the transmitter is 12 to 36 V D.C.
Sdtork electric actuator can be supply with remote position indicator. This will indicate 0-100% opening of
the valve in control room. In put to this position will be either from actuator mounted pot meter (distance
less than 5 m) or from actuator mounted current transmitter i.e.4-20m A.
• TYPE OF MOTOR:
Sdtork actuators are available with two types of motor i.e. TEFC (Totally Enclosed Fan Cooled) / TESC
(Totally Enclosed Surface Cooled) squirrel cage induction motors.
• CLASS OF INSULATION:
Motor insulation will be class ‘F’ with temperature rise limited to class ’B’ limits.
• INSULATION RESISTANCE:
Under normal operating conditions, the insulation resistance of electric circuits with respect to chassis or to
each other should be at least 20 MΩ. After a damp test, it should at least 2 MΩ.
• ELECTRICAL STRENGTH:
- The insulation strength of electrical circuits of the actuator will be as follows :
- Test voltages of individual circuits:
- Remote position transmitter 500 V, 50 HZ
- Micro switches & anti condensation heater 1,500 V, 50 HZ
- Electric motor 1,000 V, 50 Hz, at least 1,500 V
NOISE
- Acoustic pressure level max 85 dB (A)
- Acoustic power level max. 95 Db (A)
• TRIPPING TORQUE:
At the factory, the tripping torque has been adjusted as per standard selection chart of actuator, final
tripping torque adjustment will be done at site according to the valve operation torque requirement.
BASIC SPECIFICATION OF
SDTORK ELECTRICAL ACTUATOR
Data Sheet Ref. No :
SD-3000-001 sdtork ®
Quotation Ref. No
Step controller (Servo controller) and electric actuator are matched to each other in such a way that steps
of less than 0.3 % of the stroke can be executed. The control accuracy resulting from this positioning mode
is sufficient for all control application. To obtain this feature, the gearing is, to a high degree, mechanically
rigid (without elastic element) & without back-lash.
• GREASING:
Sdtork actuators are packed with grease foe 2-3 year’s maintenance-free operation at factory. Chassi
grease grade ‘H’ or SERVOREX-LO (IOC) or Univex CD of BPC or equivalent can be use. Approx. quantity
required 2.5-3 kg. Frequency of checking once in six months & affix additional quantity if required.
• MAINTENANCE:
If actuator is correctly mounted and sealed, no special maintenance is required. Check once a year the
function of motor and make sure that compartment is condensation free.
All electrical i.e. Position limit switch, Torque limit switches, Motor terminals are provided in single electrical
compartment allowing easier maintenance and field modifications.
• Ambient temperature to point 1); minimum relative humidity 10 %, maximum relative humidity 100 %
with condensation
• Small dust content of air; mean layers of dust; daily dust fall more than 35 mg/m2, but not exceeding
350 mg/m2
• Medium solar radiation with intensities > 500 W/msq and < 700 W/msq