You are on page 1of 2

Chapters

1. Introduction
2. Literature Survey on Feed Water Heaters
3. Methodology of this present scope
4. Low Pressure Heater Analysis
5. High Pressure Heater Analysis
6. Experimental setup and results
7. CFD modeling & results
8. Validation of CFD analysis
9. Conclusion
10. References
Technical Specification feed water heaters
LP heater No.:1
Type Shell & Tube
Design Pressure in Kg/Sq.
cm
i. Tube Side : 39
ii. Shell Side : Full Vacuum &
3.0
o
Design Temp in C
i. Tube Side : 150
ii. Shell Side : 120
Total tube Surface area in 871.0
M2
No. of Water Passes TWO
Tube dia. X thickness 19 x 0.889
(mm x mm)
Tube Material WELDED SS TP-304
Total No. of U-tubes 717
Weight of heater in MT
i. Empty : 21.5
ii. Operating : 25.0
iii. Flooded : 37

LP Heater No.2
Type U – Type
Quantity of Extraction 75949
Steam in Kg/Hr.
Pressure of extraction 1.44
steam
Enthalpy of Extraction 654.7
Steam K Cal/Hr.
Quantity of Condensate in 1183037
Kg/Hr.
Pressure of Condensate in 32
Ata.
Condensate inlet Temp. in 68.4
Condensate outlet Temp. 106.9
in
Surface area in Sq. M 1336
Size of tubes: OD x Thk x 19.05 x 0.889 x 11940
Leg length in (mm x mm x
mm)