Calculul hidraulic al instalatiei de alimentare cu apa rece pentru consum menajer

tron- Nr si felul armaturilor 0,7*E1 E2 E=0,7*E1+E2 qc[l/s] l[m] de v I [mmCA/m] hri=ixl ∑hri ∑ξ hri ∑hri ∑hri+ H Hg
son racordate la tronson [mm] [m/s] [mmCA] [mmCA] [mmCA] ∑hri [mmCA] [mm]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
1.1 2S 0.49 0 0.49 0.08 3.25 16 0.6 50 162.5 162.5 6.5 130 130 292.5
1.2 4S 0.98 0 0.98 0.14 2.65 20 0.7 48 127.2 195.2 0.5 13 143 338.2
1.3 6S 1.47 0 1.47 0.185 3.25 25 0.55 29 94.25 289.45 6.5 104 247 536.45
1.4 8S 1.96 0 1.96 0.22 2.65 25 0.67 37 98.05 387.5 0.5 13 260 647.5
1.5 10S 2.45 0 2.45 0.24 4.8 25 0.71 40 192 579.5 1 29 289 868.5
1.6 10R+10L+5B+10S 12.95 5 17.95 0.7 5.15 40 0.8 25 128.75 708.25 2.5 87 376 1084
1.7 15R+15L+10B+10S 19.95 7.5 27.45 0.89 0.1 50 0.66 15 1.5 709.75 2 45 421 1131
1.8 25R+25L+15B+10S 30.45 12.5 42.95 1.14 2.4 50 0.8 19 45.6 755.35 2 70 491 1246
1.9 25R+25L+15B+20S 32.9 13 45.9 1.17 1.95 50 0.8 20 39 794.35 2 70 561 1355 2000 12950
1,1O 30R+30L+20B+20S 39.9 15 54.9 1.27 14.2 50 0.9 25 353.75 1148.1 2 85 646 1794.1 2000 12950
Hnec
[mmCA]

19